1 National Seminar & Exhibition on Non-Destructive Evaluation, NDE 2014, Pune, December 4-6, 2014 (NDE-India 2014) Vol.20 No.6 (June 2015) - The e-journal of Nondestructive Testing - ISSN Performance Evaluation of 3-Axis Scanner Automated For Industrial Gamma- Ray Computed Tomography Parag Walinjkar a, Lakshminaryana Y, B S Singh, R V Acharya, Umesh Kumar, and Ashutosh Dash Isotope Production & Applications Division, Bhabha Atomic Research Centre, Mumbai-85, INDIA a pbw@barc.gov.in Abstract: The paper presents performance evaluation of automated 3-axis scanner consists of controller for mechanical manipulator and data acquisition unit for gamma-ray based Computed Tomography (CT). Data acquisition with synchronized mechanical motions has been achieved using an USB based controller. The system can scan cylindrical specimen up to 200 mm in diameter and 300 mm of height. A stainless steel prototype nuclear waste drum has been used as a specimen. The evaluation was carried out with 12mCi collimated source of Cs-137 and Φ 1x1 inch NaI(Tl) detector. Data was acquired in parallel geometry with 36 projections over 180 degrees. Each projection has 20 samples with data acquisition time of 1sec per sample. Attenuation map of the drum cross-section has been reconstructed with statistical optimization algorithm using information on geometrical parameters. The CT image obtained is in good agreement with actual specimen with specific regard to shape, size and linear attenuation coefficient within the circle of reconstruction. The results show satisfactory performance of the scanner. Keywords: Computed Tomography (CT), projection, Data Acquisition (DAQ) system, statistical optimization algorithm. Introduction Radioisotope and radiation applications in industry form an important part of using nuclear technology for development and societal benefits. The Isotope Production & Applications Division (IP&AD) of Bhabha Atomic Research Centre has made pioneering contributions to promote application of gamma sources for Non Destructive Testing and Examination (NDT&E) in industry. The Division has been active and instrumental in research and development activities pertaining to advance radiation based imaging for almost two decades. Industrial computed tomography (ICT) systems based on gamma rays and x-rays of first, second and third generation modalities have been developed and demonstrated earlier [1-3]. All the gamma-ray transmission tomography systems use either one or more collimated point sources and detector/s placed on the opposite side of an object under investigation [4]. These systems can be broadly classified into two types; one using single source with scanner and other using multiple sources without scanner. The major drawback with gamma-ray tomography systems is the relatively high cost, particularly for higher speed and higher resolution [4,5]. Hence for imaging of static objects or processes, the first generation systems using single source and a detector is preferred because of operational simplicity and lower cost. IP&AD has developed one such system using USB based ICT-controller based on narrow beam scanning technique [6]. The tomographic image generated is mainly depends on the attenuation of gamma ray through the specimen. Since the scanning becomes unavoidable part of the system the quality of image largely depends on the performance of the scanner. Therefore, performance of ICTscanner is experimentally evaluated using specimens to provide true information. Materials & Method The indigenously developed automated 3-axis scanner is a standalone system consists of a 3-axis mechanical manipulator, its controller, gamma detector and a PC as a data acquisition unit for

2 gamma-ray based Computed Tomography (CT). The block diagram of the ICT scanner is shown in the Fig. 1 below. Fig. 1: Block diagram of ICT scanner In-house developed control software for ICT-scanner facilitate user to input required scanning parameters i.e. angle of projection (Ɵ), step size (L) and dwell time as shown in Fig. 2 below. Dwell time is the time of data acquisition at each position. Based on the inputs, the total number of projections and samples are calculated and displayed. The specimen is moved in linear, vertical and angular direction to take respective positions and gamma attenuation data (counts) is automatically acquired once Start Acquisition button is pressed. The current value of sample and projection is updated at every position. The present status of the scanner is indicated by the respective indicator by turning it green. It automatically stores data of all positions required for generating tomographic image of an object as per parallel beam scanning technique [6]. Experimental Fig. 2: Snap shot of ICT-scanner software Performance evaluation of automated 3-axis ICT scanner was carried out using experimental data. The experimental arrangement to evaluate the performance of 3-axis ICT scanner is shown in Fig. 3 below. It is basically geometrical arrangement of the combination of gamma source, detector, a specimen (object under test) and the method adopted for acquiring the data for the requisite number of projections. The source detector arrangement is such that the detector is always in line with the beam of gamma source. It can scan cylindrical specimen up to 200 mm in diameter

3 and 300 mm of height. Here the specimen is placed on the 3-axis manipulator and moved keeping the source and detector at fixed position as shown in Fig. 3 below. Performance tests were carried out with a 12mCi, Cs-137 Collimated gamma source and NaI(Tl) detector of size Φ 1x1 inch. Detector γ Source Specimen Manipulator Fig. 3: The hardware design and actual photograph of ICT-scanner The ICT scanner initially tested for its mechanical operation with different sets of input parameters i.e. projection angle and step size. To find its overall performance for gamma ray tomography, the input parameters are optimized as projection angle of 5 degree, step length of 5mm and dwell time of 2sec. It set the scanning parameters as 36 numbers of projections, 40 samples per projection and 2 sec of data acquisition time per sample. Two types of preliminary experiments were performed with these scanning parameters. These experiments were carried out to analyze the operational performance of the ICT-scanner. Initially the scanning was done without any object between the source and detector i.e. for air. Then the experiments were carried out with actual objects. In first experiment a plastic bottle filled with water was scanned and in second experiment a stainless steel prototype drum with Aluminum rod and Perspex rod placed inside it was scanned with 10mm step size and 1sec dwell time. The reliability of automatic data acquisition methodology was tested by processing the acquired data, to generate a computer tomographic image of the drum cross-section, using image reconstruction algorithm known as iterative statistical optimization algorithm. This algorithm is based on the Poisson measurement statistics. Before applying the reconstruction algorithm, the projection data p is processed using Eq. 1 below I p = 0j j ln( ) I (1) j Where, I j and I 0j are the counts recorded by detector at position j of the acquired data taken with and without the object, respectively [7,8]. The reconstruction software has been developed in-house to meet the specific requirements. Result & Discussion The initial tests carried out for scanning operations shows that ICT scanner scans the specimen as per user inputs correctly. During air scan it is observed that the automatically collected data set matches with the calculated data set for the set input parameters. The data of air scan plotted as counts v/s sample position for few projections is shown in Fig. 4 below. It shows small variations within the acceptable limit of statistical error. The measurement accuracy calculated, as shown in the Table 1, from the air scan data found better than 97%. This ensures the overall performance of a gamma data acquisition system of ICT scanner is good.

4 Average counts Table 1: Measurement accuracy of scanner Minimum Maximum 3σ counts counts counts % ACCURACY (error) Fig. 4: Counts plotted against sample position The experiments carried out with objects were with regard to position, shape, size and linear attenuation coefficient within the circle of reconstruction. The results from image reconstruction of first test specimen are shown in Fig. 5 below. The line profile clearly shows the attenuation of gamma ray in the object at specific projection angle. The thin plastic container of the bottle and water inside is clearly visible in the CT image as yellow colour ring around red colour that represents water. Fig. 5: Line profile and CT images of water bottle as test object The results from image reconstruction of second test specimen of a proto type steel drum containing Al and Perspex rod are shown in Fig. 6 below. It is observed that the drum boundary and two objects inside the drum are clearly visible in the CT image. It is also observed that the CT image shows different colour for both these objects indicating difference of density but the shape of the objects is not clearly visible. The square nature seen in the CT image is because of less number of samples per projection. The contour image was generated, for boundary, which clearly shows the circular shape of the objects inside the drum.

5 It is observed that in all the scanning took approximately 6 hrs to complete a full scan during the tests. Though this arrangement took longer scanning time than other techniques the minimal hardware and lowest cost motivates the use of this scanner. Fig. 6: CT image and contour image of the drum containing Al and Perspex rods Conclusion The CT image obtained is in good agreement with actual specimen with specific regard to shape, size and linear attenuation coefficient within the circle of reconstruction. Variations in shape and size of test specimens have been visualized. The results show performance of scanner is satisfactory. Further work is in progress to improve scanning methodology to reduce the scanning time. Acknowledgments Authors acknowledge Dr K L Ramakumar, Director, RC&IG, BARC and Dr A Dash, Head, IP&AD, BARC for constant encouragement and support during this work. References [1] Umesh Kumar, et al, "Development of an Industrial Isotopic Tomographic Imaging System CITIS-I", Report BARC/1993/E/019, [2] Umesh Kumar et al, "Prototype gamma-ray computed tomographic imaging system for industrial applications", INSIGHT, Vol. 42, No. 10, [3] Umesh Kumar et al, "Behaviour of reconstructed attenuation values with varying X-ray tube voltage in an experimental third-generation industrial CT system using linear detector array", Nucl. Inst. and Meth. in Physics Research-A, Vol. 490, Isuue 1-2, pp , [4] G A Johansen, Nuclear tomography methods in industry, Nuclear Physics A 752, pp: 696c 705c, [5] IAEA-TECDOC 1589, Industrial Process Gamma Tomography, Final Report of a coordinated Research Project , Austria, IAEA, [6] Parag Walinjkar, et al, Development of Indigenous USB based ICT-Controller for Industrial Computed Tomography Scanner, proc. of National Symposium on Advances in Control & Instrumentation SACI-2014, Nov., Mumbai, pp , [7] Jongbum Kim, Sunghee Jung, Jinho Moon, Gyuseong Cho. Industrial gamma-ray tomographic scan method for large scale industrial plants, Nuclear Instruments and Methods in Physics Research A, 640: , [8] Z. Islami Rad, R. Gholipour Peyvandi, and R.Heshmati, Motion detection in CT images with a novel fast technique, Instruments and Experimental Techniques, Vol. 56, No.3, pp , 2013.

Computed Tomography for Industry Needs and Status Umesh Kumar

Computed Tomography for Industry Needs and Status Umesh Kumar Computed Tomography for Industry Needs and Status Umesh Kumar Bhabha Atomic Research Centre, Mumbai, INDIA Industrial Computed Tomography (ICT) Needs Why industrial tomography is required when many conventional

More information

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE Rajesh et al. : Proceedings of the National Seminar & Exhibition on Non-Destructive Evaluation DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE Rajesh V Acharya, Umesh Kumar, Gursharan

More information

X-ray Industrial Computed Laminography (ICL) Simulation Study of Planar Objects: Optimization of Laminographic Angle

X-ray Industrial Computed Laminography (ICL) Simulation Study of Planar Objects: Optimization of Laminographic Angle More info about this article: http://www.ndt.net/?id=21086 X-ray Industrial Computed Laminography (ICL) Simulation Study of Planar Objects: Optimization of Laminographic Angle Lakshminarayana Yenumula

More information

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT More Info at Open Access Database www.ndt.net/?id=18754 Novel evaluation method of low contrast resolution performance of dimensional X-ray CT Makoto Abe 1, Hiroyuki Fujimoto 1, Osamu Sato 1, Kazuya Matsuzaki

More information

3D Computed Tomography (CT) Its Application to Aerospace Industry

3D Computed Tomography (CT) Its Application to Aerospace Industry 3D Computed Tomography (CT) Its Application to Aerospace Industry C. Muralidhar, M. P. Subramanian, V. Ravi Shankar and G. Chandrasekhar Directorate of Non Destructive Evaluation, Defence Research & Development

More information

A PRACTICAL ALGORITHM FOR RECONSTRUCTION FROM X-RAY

A PRACTICAL ALGORITHM FOR RECONSTRUCTION FROM X-RAY A PRACTICAL ALGORITHM FOR RECONSTRUCTION FROM X-RAY BACKSCATTER DATA Young S. Ham and C.F. Poranski Materials Chemistry Branch Naval Research Laboratory Washington DC 20375 E.C. Greenawald Geo-Centers,

More information

Jonbum Kim et al. published their study on industrial gamma

Jonbum Kim et al. published their study on industrial gamma Laboratory Experiment on Non-invasive Investigation of Crude Oil Pipe by Industrial Gamma Computed Tomography Myo Chit Aung 1, Khin Khin Lay 2 1 Division of Atomic Energy, Ministry of Education, Nay Pyi

More information

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS 23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN 16-20 APRIL 2007 HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS P. Helberg 1,

More information

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct J. DHAENE* 1, E. PAUWELS 1, T. DE SCHRYVER 1, A. DE MUYNCK 1, M. DIERICK 1, L. VAN HOOREBEKE 1 1 UGCT Dept. Physics

More information

MEDICAL IMAGING 2nd Part Computed Tomography

MEDICAL IMAGING 2nd Part Computed Tomography MEDICAL IMAGING 2nd Part Computed Tomography Introduction 2 In the last 30 years X-ray Computed Tomography development produced a great change in the role of diagnostic imaging in medicine. In convetional

More information

Beam Attenuation Grid Based Scatter Correction Algorithm for. Cone Beam Volume CT

Beam Attenuation Grid Based Scatter Correction Algorithm for. Cone Beam Volume CT 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Beam Attenuation Grid Based Scatter Correction Algorithm for More Info at Open Access Database

More information

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition Bernd Schweizer, Andreas Goedicke Philips Technology Research Laboratories, Aachen, Germany bernd.schweizer@philips.com Abstract.

More information

Development of Software Package for Automated Scanning of Multiple Surface Fuel Pellets Using Ultrasonic Imaging System

Development of Software Package for Automated Scanning of Multiple Surface Fuel Pellets Using Ultrasonic Imaging System 115 Proceedings of the National Seminar & Exhibition on Non-Destructive Evaluation NDE 2009, December 10-12, 2009 Development of Software Package for Automated Scanning of Multiple Surface Fuel Pellets

More information

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection Caroline Vienne 1, Marius Costin 1 More info about this article: http://www.ndt.net/?id=21917 1 CEA, LIST, Département

More information

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa TOWARDS ESTABLISHMENT OF STANDARDIZED PRACTICE FOR ASSESSMENT OF SPATIAL RESOLUTION AND CONTRAST OF INTERNATIONAL

More information

ULTRASONIC TESTING AND FLAW CHARACTERIZATION. Alex KARPELSON Kinectrics Inc., Toronto, Canada

ULTRASONIC TESTING AND FLAW CHARACTERIZATION. Alex KARPELSON Kinectrics Inc., Toronto, Canada ULTRASONIC TESTING AND FLAW CHARACTERIZATION Alex KARPELSON Kinectrics Inc., Toronto, Canada 1. Introduction Ultrasonic Testing (UT) is a commonly used inspection method. Various techniques are employed

More information

NON-COLLIMATED SCATTERED RADIATION TOMOGRAPHY

NON-COLLIMATED SCATTERED RADIATION TOMOGRAPHY NON-COLLIMATED SCATTERED RADIATION TOMOGRAPHY Gorshkov V.A., Space Research Institute, Moscow, Russia Yumashev V.M., State corporation "Rosatom", Centre "Atom-innovation", Moscow, Russia Kirilenko K.V.,

More information

Frequency-based method to optimize the number of projections for industrial computed tomography

Frequency-based method to optimize the number of projections for industrial computed tomography More Info at Open Access Database www.ndt.net/?id=18739 Frequency-based method to optimize the number of projections for industrial computed tomography Andrea Buratti 1, Soufian Ben Achour 1, Christopher

More information

Application of MCNP Code in Shielding Design for Radioactive Sources

Application of MCNP Code in Shielding Design for Radioactive Sources Application of MCNP Code in Shielding Design for Radioactive Sources Ibrahim A. Alrammah Abstract This paper presents three tasks: Task 1 explores: the detected number of as a function of polythene moderator

More information

Image Acquisition Systems

Image Acquisition Systems Image Acquisition Systems Goals and Terminology Conventional Radiography Axial Tomography Computer Axial Tomography (CAT) Magnetic Resonance Imaging (MRI) PET, SPECT Ultrasound Microscopy Imaging ITCS

More information

An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography

An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography 4th International Symposium on NDT in Aerospace 2012 - Tu.3.A.3 An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography Jonathan HESS *, Patrick KUEHNLEIN *, Steven OECKL

More information

arxiv: v2 [cond-mat.mtrl-sci] 5 Jan 2010

arxiv: v2 [cond-mat.mtrl-sci] 5 Jan 2010 Gamma scattering scanning of concrete block for detection of voids. Shivaramu 1, Arijit Bose 2 and M. Margret 1 1 Radiological Safety Division, Safety Group, IGCAR, Kalpakaam - 63 12 (India) 2 Chennai

More information

Recognition and Measurement of Small Defects in ICT Testing

Recognition and Measurement of Small Defects in ICT Testing 19 th World Conference on Non-Destructive Testing 2016 Recognition and Measurement of Small Defects in ICT Testing Guo ZHIMIN, Ni PEIJUN, Zhang WEIGUO, Qi ZICHENG Inner Mongolia Metallic Materials Research

More information

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques SINCE2013 Singapore International NDT Conference & Exhibition 2013, 19-20 July 2013 Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60601-2-44 2001 AMENDMENT 1 2002-09 Amendment 1 Medical electrical equipment Part 2-44: Particular requirements for the safety of X-ray equipment for computed tomography Amendement

More information

Simulation of Beam Hardening in Industrial CT with x-ray and Monoenergetic Source by Monte Carlo Code

Simulation of Beam Hardening in Industrial CT with x-ray and Monoenergetic Source by Monte Carlo Code 2012, TextRoad Publication ISSN 2090-4304 Journal of Basic and Applied Scientific Research www.textroad.com Simulation of Beam Hardening in Industrial CT with x-ray and Monoenergetic Source by Monte Carlo

More information

Development of Image Processing and Analyzing Software for Nuclear Fuel Pellet End Faces Mandar Joshi a, Praveen Deshpande b, and C. P.

Development of Image Processing and Analyzing Software for Nuclear Fuel Pellet End Faces Mandar Joshi a, Praveen Deshpande b, and C. P. More Info at Open Access Database www.ndt.net/?id=15181 Development of Image Processing and Analyzing Software for Nuclear Fuel Pellet End Faces Mandar Joshi a, Praveen Deshpande b, and C. P. Navathe c

More information

CT vs. VolumeScope: image quality and dose comparison

CT vs. VolumeScope: image quality and dose comparison CT vs. VolumeScope: image quality and dose comparison V.N. Vasiliev *a, A.F. Gamaliy **b, M.Yu. Zaytsev b, K.V. Zaytseva ***b a Russian Sci. Center of Roentgenology & Radiology, 86, Profsoyuznaya, Moscow,

More information

3D X-ray Laminography with CMOS Image Sensor Using a Projection Method for Reconstruction of Arbitrary Cross-sectional Images

3D X-ray Laminography with CMOS Image Sensor Using a Projection Method for Reconstruction of Arbitrary Cross-sectional Images Ke Engineering Materials Vols. 270-273 (2004) pp. 192-197 online at http://www.scientific.net (2004) Trans Tech Publications, Switzerland Online available since 2004/08/15 Citation & Copright (to be inserted

More information

NDT OF SPECIMEN OF COMPLEX GEOMETRY USING ULTRASONIC ADAPTIVE

NDT OF SPECIMEN OF COMPLEX GEOMETRY USING ULTRASONIC ADAPTIVE NDT OF SPECIMEN OF COMPLEX GEOMETRY USING ULTRASONIC ADAPTIVE TECHNIQUES - THE F.A.U.S.T. SYSTEM INTRODUCTION O. Roy, S. Mahaut, M. Serre Commissariat a I'Energie Atomique CEAlCEREM, CE Saclay France Phased

More information

Theoretical Investigations of Tomographic Methods used for Determination of the Integrity of Spent BWR Nuclear Fuel

Theoretical Investigations of Tomographic Methods used for Determination of the Integrity of Spent BWR Nuclear Fuel a UPPSALA UNIVERSITY Department of Radiation Sciences Box 535, S-751 1 Uppsala, Sweden http://www.tsl.uu.se/ Internal report ISV-6/97 August 1996 Theoretical Investigations of Tomographic Methods used

More information

Corso di laurea in Fisica A.A Fisica Medica 4 TC

Corso di laurea in Fisica A.A Fisica Medica 4 TC Corso di laurea in Fisica A.A. 2007-2008 Fisica Medica 4 TC Computed Tomography Principles 1. Projection measurement 2. Scanner systems 3. Scanning modes Basic Tomographic Principle The internal structure

More information

SPECT QA and QC. Bruce McBride St. Vincent s Hospital Sydney.

SPECT QA and QC. Bruce McBride St. Vincent s Hospital Sydney. SPECT QA and QC Bruce McBride St. Vincent s Hospital Sydney. SPECT QA and QC What is needed? Why? How often? Who says? QA and QC in Nuclear Medicine QA - collective term for all the efforts made to produce

More information

TEP Hounsfield units. Related topics Attenuation coefficient, Hounsfield units

TEP Hounsfield units. Related topics Attenuation coefficient, Hounsfield units Hounsfield units TEP Related topics Attenuation coefficient, Hounsfield units Principle Depending on the type of CT scanner and the settings, the result of a CT scan of the same material can be different

More information

Muon imaging for innovative tomography of large volume and heterogeneous cemented waste packages

Muon imaging for innovative tomography of large volume and heterogeneous cemented waste packages Muon imaging for innovative tomography of large volume and heterogeneous cemented waste packages This project has received funding from the Euratom research and training programme 2014-2018 under grant

More information

An Investigation into the Limitations of Tomographic Scanning for Quantitative Nondestructive Gamma-ray Measurements of High Density Radioactive Waste

An Investigation into the Limitations of Tomographic Scanning for Quantitative Nondestructive Gamma-ray Measurements of High Density Radioactive Waste An Investigation into the Limitations of Tomographic Scanning for Quantitative Nondestructive Gamma-ray Measurements of High Density Radioactive Waste S.C. Kane 1, S. Croft 1, P. McClay 1, W.F. Mueller

More information

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY Prof. Yasser Mostafa Kadah www.k-space.org Recommended Textbook X-Ray Computed Tomography in Biomedical Engineering, by Robert Cierniak, Springer, 211 Computed Tomography

More information

Effects of the difference in tube voltage of the CT scanner on. dose calculation

Effects of the difference in tube voltage of the CT scanner on. dose calculation Effects of the difference in tube voltage of the CT scanner on dose calculation Dong Joo Rhee, Sung-woo Kim, Dong Hyeok Jeong Medical and Radiological Physics Laboratory, Dongnam Institute of Radiological

More information

Quality control phantoms and protocol for a tomography system

Quality control phantoms and protocol for a tomography system Quality control phantoms and protocol for a tomography system Lucía Franco 1 1 CT AIMEN, C/Relva 27A O Porriño Pontevedra, Spain, lfranco@aimen.es Abstract Tomography systems for non-destructive testing

More information

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system ECNDT 2014 Prague October 6-10, 2014 Dr. Eberhard Neuser Dr. Alexander Suppes Imagination

More information

STUDY OF FLOW PERFORMANCE OF A GLOBE VALVE AND DESIGN OPTIMISATION

STUDY OF FLOW PERFORMANCE OF A GLOBE VALVE AND DESIGN OPTIMISATION Journal of Engineering Science and Technology Vol. 12, No. 9 (2017) 2403-2409 School of Engineering, Taylor s University STUDY OF FLOW PERFORMANCE OF A GLOBE VALVE AND DESIGN OPTIMISATION SREEKALA S. K.

More information

Translational Computed Tomography: A New Data Acquisition Scheme

Translational Computed Tomography: A New Data Acquisition Scheme 2nd International Symposium on NDT in Aerospace 2010 - We.1.A.3 Translational Computed Tomography: A New Data Acquisition Scheme Theobald FUCHS 1, Tobias SCHÖN 2, Randolf HANKE 3 1 Fraunhofer Development

More information

Emission Computed Tomography Notes

Emission Computed Tomography Notes Noll (24) ECT Notes: Page 1 Emission Computed Tomography Notes Introduction Emission computed tomography (ECT) is the CT applied to nuclear medicine. There are two varieties of ECT: 1. SPECT single-photon

More information

X-ray simulation and applications

X-ray simulation and applications Computerized Tomography for Industrial Applications and Image Processing in Radiology March 15-17, 1999, Berlin, Germany DGZfP Proceedings BB 67-CD Paper 17 X-ray simulation and applications P. Hugonnard,

More information

DEVELOPMENT OF PREVENTIVE MAINTENANCE SYSTEM ARISING IN ADVANCED EDDY CURRENT TESTING USING NETWORK TOMOGRAPHY

DEVELOPMENT OF PREVENTIVE MAINTENANCE SYSTEM ARISING IN ADVANCED EDDY CURRENT TESTING USING NETWORK TOMOGRAPHY DEVELOPMENT OF PREVENTIVE MAINTENANCE SYSTEM ARISING IN ADVANCED EDDY CURRENT TESTING USING NETWORK TOMOGRAPHY F. Kojima 1, F.Kobayashi 1, A. Nishimizu 2, M. Koike 2, T. Matsui 2, H. Endo 3, T. Uchimoto

More information

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography Characterization of microshells experimented on Laser Megajoule using X-Ray tomography More info about this article: http://www.ndt.net/?id=20881 Alexandre Choux, Lise Barnouin, Ludovic Reverdy, Marc Theobald

More information

Identification of Shielding Material Configurations Using NMIS Imaging

Identification of Shielding Material Configurations Using NMIS Imaging Identification of Shielding Material Configurations Using NMIS Imaging B. R. Grogan, J. T. Mihalczo, S. M. McConchie, and J. A. Mullens Oak Ridge National Laboratory, P.O. Box 2008, MS-6010, Oak Ridge,

More information

Physical bases of X-ray diagnostics

Physical bases of X-ray diagnostics Physical bases of X-ray diagnostics Dr. István Voszka Possibilities of X-ray production (X-ray is produced, when charged particles of high velocity are stopped) X-ray tube: Relatively low accelerating

More information

Coordinate Measuring Machines with Computed Tomography

Coordinate Measuring Machines with Computed Tomography Always a Step Ahead with Quality Coordinate Measuring Machines with Computed Tomography Multisensor Coordinate Measuring Machines with Computed Tomography Computed Tomography in Coordinate Measuring Machines

More information

Comparison of Reconstruction Methods for Computed Tomography with Industrial Robots using Automatic Object Position Recognition

Comparison of Reconstruction Methods for Computed Tomography with Industrial Robots using Automatic Object Position Recognition 19 th World Conference on Non-Destructive Testing 2016 Comparison of Reconstruction Methods for Computed Tomography with Industrial Robots using Automatic Object Position Recognition Philipp KLEIN 1, Frank

More information

A THREE-DIMENSIONAL PHASED ARRAY ULTRASONIC TESTING TECHNIQUE

A THREE-DIMENSIONAL PHASED ARRAY ULTRASONIC TESTING TECHNIQUE A THREE-DIMENSIONAL PHASED ARRAY ULTRASONIC TESTING TECHNIQUE So KITAZAWA, Naoyuki KONO, Atsushi BABA and Yuji ADACHI HITACHI, Ltd., Japan Mitsuru ODAKURA HITACHI-GE Nuclear Energy, Ltd., Japan Introduction

More information

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY David K. Lehmann 1, Kathleen Brockdorf 1 and Dirk Neuber 2 1 phoenix x-ray Systems + Services Inc. St. Petersburg, FL, USA 2 phoenix x-ray Systems + Services

More information

USING cone-beam geometry with pinhole collimation,

USING cone-beam geometry with pinhole collimation, IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 56, NO. 3, JUNE 2009 687 A Backprojection-Based Parameter Estimation Technique for Skew-Slit Collimation Jacob A. Piatt, Student Member, IEEE, and Gengsheng L.

More information

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling nd International Symposium on NDT in Aerospace - We..A. Comparison of Probing Error in Dimensional Measurement by Means of D Computed Tomography with Circular and Helical Sampling Jochen HILLER, Stefan

More information

CoE4TN4 Image Processing. Chapter 5 Image Restoration and Reconstruction

CoE4TN4 Image Processing. Chapter 5 Image Restoration and Reconstruction CoE4TN4 Image Processing Chapter 5 Image Restoration and Reconstruction Image Restoration Similar to image enhancement, the ultimate goal of restoration techniques is to improve an image Restoration: a

More information

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM M. Simon, C. Sauerwein, I. Tiseanu, S. Burdairon Hans Wälischmiller GmbH Klingleweg 8, D-88709 Meersburg, Germany e-mail: ms@hwm.com ABSTRACT A new flexible

More information

Development of Data Acquisition Software for Ultrasonic Inspection of Reactor Pressure Vessel Weld Joints in Boiling Water Reactors

Development of Data Acquisition Software for Ultrasonic Inspection of Reactor Pressure Vessel Weld Joints in Boiling Water Reactors More info about this article: http://www.ndt.net/?id=21079 Development of Data Acquisition Software for Ultrasonic Inspection of Reactor Pressure Vessel Weld Joints in Boiling Water Reactors RK Jain, SK

More information

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste. 16648 Stephen Halliwell, VJ Technologies Inc, 89 Carlough Road, Bohemia, NY 11716, USA.

More information

Computer Aided Defect Detection Strategy for Welded Joints.

Computer Aided Defect Detection Strategy for Welded Joints. Computer Aided Defect Detection Strategy for Welded Joints. Samadrita Chakraborty 1*, Rajesh Acharya 2, R.K. Gupta 1, V.K. Mishra 1, Umesh Kumar 2, S.P. Srivastava 1, 1 Centre for Design and Manufacture,

More information

CALIBRATIONS FOR ANALYZING INDUSTRIAL SAMPLES ON MEDICAL CT SCANNERS

CALIBRATIONS FOR ANALYZING INDUSTRIAL SAMPLES ON MEDICAL CT SCANNERS CALIBRATIONS FOR ANALYZING INDUSTRIAL SAMPLES ON MEDICAL CT SCANNERS INTRODUCTION Patricia K. Hunt, Philip Engler, and William D. Friedman BP American Research and Development 4440 Warrensville Center

More information

Three-dimensional nondestructive evaluation of cylindrical objects (pipe) using an infrared camera coupled to a 3D scanner

Three-dimensional nondestructive evaluation of cylindrical objects (pipe) using an infrared camera coupled to a 3D scanner Three-dimensional nondestructive evaluation of cylindrical objects (pipe) using an infrared camera coupled to a 3D scanner F. B. Djupkep Dizeu, S. Hesabi, D. Laurendeau, A. Bendada Computer Vision and

More information

SEM Drift Correction. Procedure Guide

SEM Drift Correction. Procedure Guide SEM Drift Correction Procedure Guide Introduction Vic-2D includes experimental functionality to correct for both drift and geometric distortions that occur in images taken using SEMs. The correction requires

More information

THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS

THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS A. Campos a*, A. Zorrilla a, F. Lasagni a a Materials & Processes dept., Center for Advanced Aerospace Technologies

More information

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape Tasuku Ito 1, Yutaka Ohtake 1, Yukie Nagai 2, Hiromasa Suzuki 1 More info about this article: http://www.ndt.net/?id=23662

More information

Performance Analysis of an After Cooler Used In High Power Engine Using CFD

Performance Analysis of an After Cooler Used In High Power Engine Using CFD International OPEN ACCESS Journal Of Modern Engineering Research (IJMER) Performance Analysis of an After Cooler Used In High Power Engine Using CFD M. Safraaj Salaamer 1, Dr. K. S. Amirthagadeswaran 2,

More information

Combining Analytical and Monte Carlo Modelling for Industrial Radiology

Combining Analytical and Monte Carlo Modelling for Industrial Radiology 19 th World Conference on Non-Destructive Testing 2016 Combining Analytical and Monte Carlo Modelling for Industrial Radiology Carsten BELLON, Gerd-Rüdiger JAENISCH, Andreas DERESCH BAM Bundesanstalt für

More information

SUPPLEMENTARY INFORMATION

SUPPLEMENTARY INFORMATION SUPPLEMENTARY INFORMATION doi:10.1038/nature10934 Supplementary Methods Mathematical implementation of the EST method. The EST method begins with padding each projection with zeros (that is, embedding

More information

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago Optimization of CT Simulation Imaging Ingrid Reiser Dept. of Radiology The University of Chicago Optimization of CT imaging Goal: Achieve image quality that allows to perform the task at hand (diagnostic

More information

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube T. Donath* a, F. Pfeiffer a,b, O. Bunk a, W. Groot a, M. Bednarzik a, C. Grünzweig a, E. Hempel c, S. Popescu c, M. Hoheisel

More information

Estimating 3D Respiratory Motion from Orbiting Views

Estimating 3D Respiratory Motion from Orbiting Views Estimating 3D Respiratory Motion from Orbiting Views Rongping Zeng, Jeffrey A. Fessler, James M. Balter The University of Michigan Oct. 2005 Funding provided by NIH Grant P01 CA59827 Motivation Free-breathing

More information

Optimization of scanner parameters for dual energy micro-ct

Optimization of scanner parameters for dual energy micro-ct Optimization of scanner parameters for dual energy micro-ct E. PAUWELS* 1, J. DHAENE 1, A. DE MUYNCK 1 E., M. DIERICK 1, L. VAN HOOREBEKE 1 1 UGCT Dept. Physics and Astronomy, Ghent University, Proeftuinstraat

More information

Digital Image Processing

Digital Image Processing Digital Image Processing SPECIAL TOPICS CT IMAGES Hamid R. Rabiee Fall 2015 What is an image? 2 Are images only about visual concepts? We ve already seen that there are other kinds of image. In this lecture

More information

Investigation on reconstruction methods applied to 3D terahertz computed Tomography

Investigation on reconstruction methods applied to 3D terahertz computed Tomography Investigation on reconstruction methods applied to 3D terahertz computed Tomography B. Recur, 3 A. Younus, 1, P. Mounaix 1, S. Salort, 2 B. Chassagne, 2 P. Desbarats, 3 J-P. Caumes, 2 and E. Abraham 1

More information

Computational Medical Imaging Analysis

Computational Medical Imaging Analysis Computational Medical Imaging Analysis Chapter 1: Introduction to Imaging Science Jun Zhang Laboratory for Computational Medical Imaging & Data Analysis Department of Computer Science University of Kentucky

More information

Modeling the ORTEC EX-100 Detector using MCNP

Modeling the ORTEC EX-100 Detector using MCNP Modeling the ORTEC EX-100 Detector using MCNP MCNP is a general-purpose Monte Carlo radiation transport code for modeling the interaction of radiation with materials based on composition and density. MCNP

More information

Other Major Component Inspection I

Other Major Component Inspection I Other Major Component Inspection I Mechanized UT inspections on complex nozzle geometries S. Farley, R. Jansohn, Westinghouse Electric Germany, Germany; H. Ernst, Schweizerischer Verein für technische

More information

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

C a t p h a n / T h e P h a n t o m L a b o r a t o r y C a t p h a n 5 0 0 / 6 0 0 T h e P h a n t o m L a b o r a t o r y C a t p h a n 5 0 0 / 6 0 0 Internationally recognized for measuring the maximum obtainable performance of axial, spiral and multi-slice

More information

Visualisation : Lecture 1. So what is visualisation? Visualisation

Visualisation : Lecture 1. So what is visualisation? Visualisation So what is visualisation? UG4 / M.Sc. Course 2006 toby.breckon@ed.ac.uk Computer Vision Lab. Institute for Perception, Action & Behaviour Introducing 1 Application of interactive 3D computer graphics to

More information

Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran. DXRaySMCS First User Friendly Interface Developed for Prediction of Diagnostic Radiology X-Ray Spectra Produced by Monte Carlo (MCNP-4C) Simulation in Iran M.T. Bahreyni Toosi a*, H. Moradi b, H. Zare

More information

BME I5000: Biomedical Imaging

BME I5000: Biomedical Imaging 1 Lucas Parra, CCNY BME I5000: Biomedical Imaging Lecture 4 Computed Tomography Lucas C. Parra, parra@ccny.cuny.edu some slides inspired by lecture notes of Andreas H. Hilscher at Columbia University.

More information

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada Overview Introduction Overview Introduction Tecniques of imaging in Overview Introduction Tecniques of imaging

More information

Determination of the aperture of the LHCb VELO RF foil

Determination of the aperture of the LHCb VELO RF foil LHCb-PUB-214-12 April 1, 214 Determination of the aperture of the LHCb VELO RF foil M. Ferro-Luzzi 1, T. Latham 2, C. Wallace 2. 1 CERN, Geneva, Switzerland 2 University of Warwick, United Kingdom LHCb-PUB-214-12

More information

Diagnostic imaging techniques. Krasznai Zoltán. University of Debrecen Medical and Health Science Centre Department of Biophysics and Cell Biology

Diagnostic imaging techniques. Krasznai Zoltán. University of Debrecen Medical and Health Science Centre Department of Biophysics and Cell Biology Diagnostic imaging techniques Krasznai Zoltán University of Debrecen Medical and Health Science Centre Department of Biophysics and Cell Biology 1. Computer tomography (CT) 2. Gamma camera 3. Single Photon

More information

Study on Synchronization for Laser Scanner and Industrial Robot

Study on Synchronization for Laser Scanner and Industrial Robot Study on Synchronization for Laser Scanner and Industrial Robot Heeshin Kang 1 1 Korea Institute of Machinery and Materials, Daejeon, Korea 173 Abstract On this paper, a study of robot based remote laser

More information

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D. Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D. Applied Science Laboratory, GE Healthcare Technologies 1 Image Generation Reconstruction of images from projections. textbook reconstruction advanced

More information

Introduction to Biomedical Imaging

Introduction to Biomedical Imaging Alejandro Frangi, PhD Computational Imaging Lab Department of Information & Communication Technology Pompeu Fabra University www.cilab.upf.edu X-ray Projection Imaging Computed Tomography Digital X-ray

More information

Multi-spectral (W, Mo, Cu, and Ag) XCT measurements

Multi-spectral (W, Mo, Cu, and Ag) XCT measurements Multi-spectral (W, Mo, Cu, and Ag) XCT measurements Marko Katić 1, Damir Markučič 1, Gorana Baršić 1 Faculty of mechanical engineering and naval architecture, Ivana Lucica 5, Zagreb, Croatia, marko.katic@fsb.hr

More information

Adaptive Focusing Technology for the Inspection of Variable Geometry. Composite Material

Adaptive Focusing Technology for the Inspection of Variable Geometry. Composite Material More info about this article: http://www.ndt.net/?id=22711 Adaptive Focusing Technology for the Inspection of Variable Geometry Composite Material Etienne GRONDIN 1 1 Olympus Scientific Solutions Americas,

More information

DUAL energy X-ray radiography [1] can be used to separate

DUAL energy X-ray radiography [1] can be used to separate IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 53, NO. 1, FEBRUARY 2006 133 A Scatter Correction Using Thickness Iteration in Dual-Energy Radiography S. K. Ahn, G. Cho, and H. Jeon Abstract In dual-energy

More information

A method and algorithm for Tomographic Imaging of highly porous specimen using Low Frequency Acoustic/Ultrasonic signals

A method and algorithm for Tomographic Imaging of highly porous specimen using Low Frequency Acoustic/Ultrasonic signals More Info at Open Access Database www.ndt.net/?id=15210 A method and algorithm for Tomographic Imaging of highly porous specimen using Low Frequency Acoustic/Ultrasonic signals Subodh P S 1,a, Reghunathan

More information

DUE to beam polychromacity in CT and the energy dependence

DUE to beam polychromacity in CT and the energy dependence 1 Empirical Water Precorrection for Cone-Beam Computed Tomography Katia Sourbelle, Marc Kachelrieß, Member, IEEE, and Willi A. Kalender Abstract We propose an algorithm to correct for the cupping artifact

More information

INSPECTION USING SHEAR WAVE TIME OF FLIGHT DIFFRACTION (S-TOFD) TECHNIQUE

INSPECTION USING SHEAR WAVE TIME OF FLIGHT DIFFRACTION (S-TOFD) TECHNIQUE INSPECTION USING SHEAR WAVE TIME OF FIGHT DIFFRACTION (S-TOFD) TECHNIQUE G. Baskaran, Krishnan Balasubramaniam and C.V. Krishnamurthy Centre for Nondestructive Evaluation and Department of Mechanical Engineering,

More information

Micro-CT in situ study of carbonate rock microstructural evolution for geologic CO2 storage

Micro-CT in situ study of carbonate rock microstructural evolution for geologic CO2 storage Downloaded from orbit.dtu.dk on: Apr 10, 2018 Micro-CT in situ study of carbonate rock microstructural evolution for geologic CO2 storage Zheng, Yi; Yang, Yan; Rogowska, M.; Gundlach, Carsten Published

More information

4th WSEAS/IASME International Conference on EDUCATIONAL TECHNOLOGIES (EDUTE'08) Corfu, Greece, October 26-28, 2008

4th WSEAS/IASME International Conference on EDUCATIONAL TECHNOLOGIES (EDUTE'08) Corfu, Greece, October 26-28, 2008 Loyola Marymount University One LMU Dr. MS 8145 Los Angeles, CA, 90045 USA Abstract: - The project involves the evaluation of the effectiveness of a low-cost reverse engineering system. Recently, the reverse

More information

DEVELOPMENT OF POSITION MEASUREMENT SYSTEM FOR CONSTRUCTION PILE USING LASER RANGE FINDER

DEVELOPMENT OF POSITION MEASUREMENT SYSTEM FOR CONSTRUCTION PILE USING LASER RANGE FINDER S17- DEVELOPMENT OF POSITION MEASUREMENT SYSTEM FOR CONSTRUCTION PILE USING LASER RANGE FINDER Fumihiro Inoue 1 *, Takeshi Sasaki, Xiangqi Huang 3, and Hideki Hashimoto 4 1 Technica Research Institute,

More information

Three-Dimensional Laser Scanner. Field Evaluation Specifications

Three-Dimensional Laser Scanner. Field Evaluation Specifications Stanford University June 27, 2004 Stanford Linear Accelerator Center P.O. Box 20450 Stanford, California 94309, USA Three-Dimensional Laser Scanner Field Evaluation Specifications Metrology Department

More information

Non-Stationary CT Image Noise Spectrum Analysis

Non-Stationary CT Image Noise Spectrum Analysis Non-Stationary CT Image Noise Spectrum Analysis Michael Balda, Björn J. Heismann,, Joachim Hornegger Pattern Recognition Lab, Friedrich-Alexander-Universität Erlangen Siemens Healthcare, Erlangen michael.balda@informatik.uni-erlangen.de

More information

On the impact of probing form error on form measurement in Computed Tomography

On the impact of probing form error on form measurement in Computed Tomography On the impact of probing form error on form measurement in Computed Tomography Jan Lasson Andreasen 1, Filippo Montanari 2, Leonardo De Chiffre 2 More info about this article: http://www.ndt.net/?id=23729

More information

Washability Monitor for Coal Utilizing Optical and X-Ray Analysis Techniques

Washability Monitor for Coal Utilizing Optical and X-Ray Analysis Techniques Washability Monitor for Coal Utilizing Optical and X-Ray Analysis Techniques Jan F. Bachmann, Claus C. Bachmann, Michael P. Cipold, Helge B. Wurst J&C Bachmann GmbH, Bad Wildbad, Germany Mel J. Laurila

More information

Continuation Format Page

Continuation Format Page C.1 PET with submillimeter spatial resolution Figure 2 shows two views of the high resolution PET experimental setup used to acquire preliminary data [92]. The mechanics of the proposed system are similar

More information