Deformable Registration of Planning CT and Daily Cone beam CT for Image Guided Adaptive Radiation Therapy System

Size: px
Start display at page:

Download "Deformable Registration of Planning CT and Daily Cone beam CT for Image Guided Adaptive Radiation Therapy System"

Transcription

1 Deformable Regtration of Planning CT and Daily Cone beam CT for Image Guided Adaptive Radiation Therapy System Dengwang Li*, Xiuying Wang**, Hongjun Wang*, Yong Yin***, David Dagan Feng** * School of Information Science and Engineering, Shandong University, China ( lidengwang@mail.sdu.edu.cn) ** Biomedical & Multimedia Information Technology Research Group, University of Sydney, Australia ( xiuying@it.usyd.edu.au) *** Department of Radiation Oncology, Shandong Cancer Hospital, China, ( yinyongsd@yahoo.com.cn) Abstract: Adequate medical image data analys could provide improved dease understanding, diagnos, staging, and measurement of the response to the treatment, especially for radiation therapy system modeling. In image guided radiation therapy systems, it of great importance to regter the planning images with the daily images for adaptive radiation therapy. Because there are various local and global deformations between the image pairs to regter, we estimate the deformation in a coarse-to-fine manner using orthogonal wavelet bas. The wavelet coefficients are estimated by minimizing the energy function, where the internal forces are derived from the Navier partial differential equations (PDE) and the external forces are derived from the similarity measure between the regtration pairs using normalized mutual information. The experimental results on head-neck and chest cancer studies with both intra- and inter-fraction regtration are presented. And we validated the regtration method quantitatively using synthetic, pre-defined deformations, and qualitatively using clinical images. The applications of proposed algorithm for image guided adaptive radiation therapy, including automatic deformable re-contouring and automatic deformable re-dosing throughout the course of radiotherapy were also studied. Keywords: biomedical control system; image guided radiation therapy; deformable regtration; wavelet; multi-resolution; cone beam CT; Planning CT; adaptive radiation therapy I. INTRODUCTION Medical imaging data analys plays an important role in improving the clinical treatment, especially for radiation therapy system modeling. Radiation therapy has been proven as an effective treatment for many localized cancer types. Approximately 60% of cancer patients are treated with external beam radiotherapy during dease management (Khan and Stathak, 010). During the past 15 years, accuracy of delivered treatment doses has been greatly improved by the use of intensity modulated radiotherapy (IMRT). Although the dose can be accurately delivered to the planned location, intra and inter-fraction changes in patient geometry have required the use of motion-related margins in treatment plans (Stanton et al., 010). Recently, the advancement of volumetric imaging in the treatment room by using kilo-voltage cone beam computer tomography (CBCT), has provided the imaging data needed to perform image guided radiation therapy (IGRT) and adaptive radiation therapy (ART) (Sonke et al., 009). The goals of both IGRT and ART are to increase the radiation dose to the tumor, while minimizing the amount of healthy tsue exposed to radiation (Paquin et al., 009). Numerous clinical studies and simulations have demonstrated that such treatments can decrease both spreading of cancer in the patient and reducing healthy tsue complications (Lu et al., 006). In the adaptive radiation therapy treatment, to maximize radiation dose to the tumor and in the mean time to minimize radiation to healthy tsues, the patient alignment and the information on radiation beam angles are required to be updated continuously in the treatment room (Noel and et al., 010). The image guided adaptive radiation therapy provides method to monitor and adjust the treatment plans to accommodate the changes introduced by patients or organs. The concepts require advanced image processing tools in order to be successful in clinical practice. Deformable regtration algorithms play an essential role in optimizing radiation dose delivery in both of ART and IGRT systems. For instance, regtration of planning CT images with daily CBCT images can adjust the radiation planning. In addition, deformable regtration also important for treatment re-planning via re-contouring and re-dosing the daily CBCT when implementing radiation therapy planning (Lu et al., 006). Research has been done on deformable regtration for planning CT and CBCT. For instance, B-spline based regtration algorithms were used to estimate the deformation (Paquin et al., 009), and in their work multi-scale deformable strategy was used to improve the regtration efficiency. In the work by (Brock et al., 006), finite element model (FEM) was used for the regtration of planning CT and CBCT, which was aiming for obtaining a more accurate assessment of tumor response. In the head and neck cancer diagnos, demons deformable regtration algorithm was used for the CBCT Copyright by the International Federation of Automatic Control (IFAC) 601

2 guided procedures (Nithiananthan et al., 009). Optical flow based regtration was used for CBCT based IGRT (Østergaard Noe et al., 008) and the acceleration via graphics processing units (GPU) improved the regtration efficiency for an online CBCT system. In th work, for estimating deformation more efficiently, we use a multi-resolution wavelet representation to express the deformation field. Clinical applications in IGRT system demonstrate the efficiency of our proposed algorithm. II. MATERIAL Datasets were collected from 10 patients treated under the on-board imager (OBI cone beam CT, Varian Medical System) which has been in daily clinical use at Shandong Cancer Hospital. Before treatment planning, each patient underwent a series of imaging studies including an intravenous contrast planning CT imaging (Philips Brilliance Big Bore 16). Then the GTV (gross tumor volume) and PTV (planning target volume) were delineated on every section of the planning CT scans by the radiation oncologts. Radiation Physiatrt contoured the organs such as liver, external surface, spinal cord, kidneys, spleen, and stomach on the planning CT. These contours were reviewed and edited by radiation oncologts. Finally treatment planning made with four components including radiotherapy structure (RTstruct), radiotherapy planning (RTplan), radiotherapy dosing (RTdose) and Dose Volume Htograms (DVH) analys. At the time of each delivered treatment fraction, a KV CBCT was obtained during normal breathing. Of the 10 patients investigated, 5 cases had head-neck cancer and another 5 cases had chest cancer, where planning CT image size 51x51x96 and CBCT image size 384x384x64. The methods used for radiotherapy are IMRT for head-neck (H&N) and conformal radiation therapy (CRT) for chest. III. DEFORMABLE REGISTRATION ALGORITHM Firstly, we express deformable process using Navier partial differential equations (PDE), and then the deformation field represented using the wavelet bas. The deformation energy function includes two components. The first one internal force which derived from the Navier PDE, and the second one the external forces which are the normalized mutual information of image pairs to be regtered. A. Deformable regtraion problem The equilibrium state for an otropic homogeneous body can be described by Navier partial differential equation (PDE) (Holden, 008). In contrast to classic thin-plate or B-spline based regtration method, Navier PDE a physical model based method for deformable regtration. Navier PDE models movement of the organ tsues as an elastic object because that organs can be considered as elastic media that are exposed to external forces and are smoothly deformed. As in the multcale matching method by (Bajcsy and Kovacic, 1989), during the deformation process it assumes that the external forces are applied to deform the organs and tsues until an equilibrium state between the external forces and internal forces. Th process can be formulated as (Broit, 1981). μ u λ μ θ i xi + ( + ) + F = 0 i (i=1,,3), (1) In (1), θ cubical dilation and has following expression, θ 1 3 = + + x1 x x3 In (1)-(), X=(x 1, x, x 3 ) T represents the coordinate system before deformation process and F=(F 1, F, F 3 ) T the vector of external forces which are dtributed across organ and tsues. As in (Bajcsy and Kovacic, 1989), elastic constants µ and λ define the elastic properties of the body and u=(u 1, u, u 3 ) T the dplacement fields to find. Thus, the matching process through elastic deformation turns into the problem of deriving forces and selecting elastic properties, and then leading to constent dplacements. Thereby we model the deformable regtration process using Navier PDE that consted of external forces, internal forces and dplacement fields. B. Wavelet based regtration method Firstly, the internal force, Internal(c), in our energy function can be modeled by the first part in (1) while θ substituted by equation (): p u x q Internal ( c) = μ dx (3) p= 1 q= ( λ+ μ) + + x1 x x3 As mentioned before, λ and µ are Lame s coefficients which reflect the elastic properties of the organs or tsues. These parameters values depend on the properties of the structures involved in the regtration. For example, Lame s coefficients for bone tsues and soft tsues are different from each other. In our work, we chose λ=0 and µ=1 for computational simplicity. The use of warp complexity by a coarse-to-fine strategy to express the deformation field effective to recover the deformation in the regtration process. The wavelet bas, which multi-resolution approximation of deformation field, suitable for such a coarse-to-fine optimization process starting from the low resolution approximation of global deformation, through the details in its different orientations, and ending with finest details of local deformation. Furthermore, wavelet bas has the advantage over Navier- Cauchy eigen functions because they allow deformations with local support to be modeled from a finite set of bas functions (Holden, 008). So we can do deformable regtration by expressing the deformation field using wavelet representation. Here, we expand the elastic deformation field u with wavelet transform and then estimate the wavelet parameter vector c, for 3D that yields: () 60

3 / 1 x = x+ / y = y+ / 3 z = z+ where (x, y, z) are coordinates in the floating image and (x /, y /, z / ) are corresponding coordinates in the reference image. The regtration algorithm estimates the wavelet coefficient c by minimizing the energy function in following sections. The 3D separable wavelet decomposition of deformation field, u(x), everywhere within a cubical support N=(N x,n y,n z ) can be presented : N -1 u K= 0 N K = ( kx, ky, kz), X = ( xyz,, ), i = 1,, 3 J i J i1 1 J ( X) cj ΚΦ ( X K) = + J 8 N j -1 j s j c jkφ j= R s= K = 0 j j j N = ( Nx, Ny, Nz) ( X K ) In (5), as in normal wavelet transformation, i an index denoting the three directions x, y and z of the vector function u(x), s an index denoting the subband, j an index denoting the resolution levels, and k=(k x, k y, k z ) the translational index j j within N N = ( N, N, N ) support. Each wavelet j x y z coefficient c indexed by the directions i, the orientation s, the resolution j, and the spatial location k it stands for. The bas functions are 3D functions that are translated across a cubical grid with intervals of j and within a support of N=(N x,n y,n z ). Each bas function weighted by the corresponding wavelet coefficient c (4) (5). The bas functions are a tensor product of one-dimensional scaling and wavelet functions. Substituting the deformation field, u, in (3) as represented in (5) results in a linear combination of the integral (Gefen et al., 003). It can be concluded that the result linearly proportional to the Wavelet-Galerkin dcretization matrix of the homogenous static Navier PDE (Gefen et al., 004). Th implies that minimizing the elastic energy equivalent to solving Navier PDE. C. Similarity measure as the Constraint Once the internal force and expression of the deformation field are obtained, the most important part of the elastic matching model where and how the external forces are applied in order to obtain constent deformation. The solution to th problem depends on the forces and with the appropriate force modeling with which we can estimate the deformation locally as well as globally. There are many different ways to formulated the external forces, such as using information from the input data, from external knowledge (i.e., interactively or from a knowledge base) or from some other processes. In the regtration process the task of external forces to bring similar regions in patient images into correspondence. So the external force which we need then the global and local similarity measure between the region at some particular position x = (x 1, x, x 3 ) T in one object and corresponding regions in another object at position x + u, u = (u l, u, u 3 ) T. The similarity function at some particular position x denoted as S(u). The best possible match expected for the dplacement vector u which maximizes S. Provided that the similarity function has a maximum, a force proportional to the gradient vector of the similarity function S(u) can be applied to increase the similarity measure. The external forces are determined in such a way that an image-based similarity metric maximized. Using image intensity as the similarity measure, for instance, normalized mutual information (NMI), has the advantage of directly exploiting the raw data without requiring segmentation or extensive user interaction. The external force defined as a proportion to the NMI. Because the energy function should be minimized for estimating the wavelet coefficients, here we define external forces as the inverse of NMI: external c ( ) 1/ NMI( X, X ( u)) = (6) The energy function E(c) composed of external forces, external(c), and internal forces, internal(c): E ( c ) = internal ( c ) +external(c) (7) The deformation determined by the regtration parameters that are represented as the wavelet coefficients c. Firstly wavelet coefficients in the highest scales corresponding to the lowest resolution signal component are estimated and then the wavelet coefficients corresponding to higher resolution signal components are estimated. Normally, the number of parameters c identical to the number of grid points in the represented transformation cubical support, and the optimization algorithm needs to handle a large number of parameters. However, since the deformation of interest (the elastic deformation) by its nature smooth, it can be estimated with only lower resolution levels and still can provide reasonable accuracy. In our work, we use the sixth resolution level. In order to simplify expression for the elastic energy and to reduce computational complexity, it assumed that the scaling and wavelet functions used satfy a principle which called threefold orthogonality. The consequence of satfying th property of threefold orthogonality that minimizing the elastic energy of the deformation equivalent to minimizing separately the elastic energy of the different deformation components (Gefen et al., 003). In our work, we only approximate threefold orthogonality using semi-orthogonal spline wavelet of order 3. The outputs of regtration are deformation maps that are the voxel-to-voxel dplacements between reference image and floating images. 603

4 IV. EXPERIMENT AND DISCUSSION CBCT-CBCT, PCT-PCT and PCT-CBCT are regtered respectively for both mono-modality and multi-modality experiments. We compare proposed method with traditional B- spline based free from deformation method. Both artificially deformed images and real clinical images are performed in our experiment for validation. A. Validation of the algorithm with known deformation Experiments on a set of reference and floating image pairs with known deformations were carried out to establh the ground truth for validating regtration accuracy. In our experiment, floating images were obtained by deforming the reference images using known B-spline vector, and therefore the deformation between reference image and floating image was available as ground truth. The difference between known deformations and deformation vectors calculated by proposed algorithm can be served as a criterion for accuracy evaluation. Ground truth data should be obtained for evaluating the efficiency of algorithm qualitatively. We applied three levels of known deformation fields on reference images. Both monomodality and multi-modality image regtrations were tested in the experiments. We repeated th procedure for all different PCT-CBCT image pairs, and PCT-CBCT image pairs were regtered by oncologts using commercial software manually in Shandong cancer hospital before our experiment. PCT-PCT, CBCT-CBCT and PCT-CBCT were regtered respectively. For each experiment, the floating images were deformed used known spline vectors as mentioned before, and then regtered with the reference image. We computed the deformation difference (DD) with the pixel-we sum of mean absolute difference between the vector deformation worked out by proposed method and the known vector deformation for each pair of images. Table 1 the DD comparon for the H&N patients between the proposed wavelet based method (WR) and the traditional B- spline based free form deformation method (FFD) (Mattes et al., 003), while Table for the chest cases. Each value in Table 1 and Table the mean value of all experiments using clinical data. Table 1. H&N-Deformation difference between the WR and FFD PCT-PCT CBCT-CBCT PCT-CBCT FFD(D1) WR(D1) FFD(D) WR(D) FFD(D3) WR(D3) Table. Chest-Deformation difference between the WR and FFD PCT-PCT CBCT-CBCT PCT-CBCT FFD(D1) WR(D1) FFD(D) WR(D) FFD(D3) WR(D3) From Table 1 and Table, DDs gained by WR are always smaller than the FFD, indicating that the WR more accurate than the FFD for three level of deformation. The CBCT images contain noe and artifact which would reduce the regtration accuracy and robustness. Furthermore, the regtration accuracy affected by the deformation between the reference image and the floating image. Larger deformation can decrease the accuracy. However, from the tables, WR more robust than FFD method with more stable lower DD for three kinds of regtration and three levels of deformation. Chest deformation larger than H&N deformation, from tables (1) and () deformation in chest more difficult to resume than the deformation in H&N. Accuracy of the WR regtration was also demonstrated by better vualization of the checkboard images after regtration from figure 1. Fig. 1. Checkboard after planning CT and CBCT deformable regtration, the first row using WR, the second row using FFD (Chest patient) V. CLINICAL APPLICATION FOR ADAPTIVE RADIATION THERAPY Deformable automatic re-contouring and re-dosing for improving the treatment processing are ART applications of deformable regtration. We performed qualitative evaluation of the automatically generated contours for all cases by vual inspection of the contour matches with the underlying structures in CBCT images. The deformable regtration technique provides the voxelto-voxel mapping between reference image and floating image. The vertices of the reference surface were dplaced in accordance with the deformation map, forming the deformed surface. The new contours were reconstructed by cutting the deformed surface slice by slice along transversal, sagittal and coronal directions (Lu et al., 006). The contours and dose in planning CT image can be transferred to CBCT image by deformation maps. Figure one example of the chest patient, where contours in CBCT are generated automatically by the deformation map. Similarly, figure 3 shows corresponding dose dtributing in CBCT generated automatically by same deformation map. After stattic analys with the radiation oncologt, the overlap between the automatically generated contours and the contours delineated by the oncologt using the planning system over 90%, while the dose dtributing overlap also over 90%. The WR deformable regtration algorithm provides deformation maps to quickly create, transform, quantitative 604

5 analys, aiding adaptive therapy, transferring contours and dose to radiation therapy treatment planning systems, and archiving contours and dose for patient follow-up and management. Fig.. Re-contouring in CBCT image using the deformation map for chest patient. The first row the planning CT which contoured by the oncologt manually. Contours in the second row are generated by the deformation map automatically using the wavelet based regtration. Fig. 3. Re-dosing in CBCT image using the deformation map for chest patient. The first row dose dtributing in the planning CT which generated by the oncologt using planning system. The second row automatically generated dose dtributing by the deformation map. VI. CONCLUSION In th paper, we presented a deformable regtration method for image guided adaptive radiation therapy based on multi-resolution wavelet. After obtaining the deformation maps with the regtration method, adaptive re-contouring and redosing can be achieved for the image guided adaptive radiation therapy application. ACKNOWLEDGMENT Th work supported by the Shandong Natural Science Foundation (ZR010HM010 and ZR010HM071) and NSFC (National Natural Science Foundation of China: ). Th work also supported ARC and PolyU grants. REFERENCES Bajcsy, R., and Kovacic, S. (1989). Multiresolution elastic matching. Computer Vion, Graphics, and Image Processing 46, 1-1. Brock, K. K., Dawson, L. A., Sharpe, M. B., Moseley, D. J., and Jaffray, D. A. (006). Feasibility of a novel deformable image regtration technique to facilitate classification, targeting, and monitoring of tumor and normal tsue. International Journal of radiation oncology, biology, physics 64, Broit, C. (1981). Optimal Regtration of Deformed Images. Ph.D.thes, Computer and Information Science Dept., University of Pennsylvania, Philadelphia, PA. Gefen, S., Tretiak, O., and Nsanov, J. (003). Elastic 3-D alignment of rat brain htological images. Medical Imaging, IEEE Transactions on, Gefen, S., Tretiak, O., Bertrand, L., Rosen, G. D., and Nsanov, J. (004). Surface alignment of an elastic body using a multiresolution wavelet representation. Biomedical Engineering, IEEE Transactions on 51, Holden, M. (008). A Review of Geometric Transformations for Nonrigid Body Regtration. Medical Imaging, IEEE Transactions on 7, Sonke, J. J, Maddalena, R., Jochem, W., Marcel van, H., Eugene, D., and Jose, B. (009). Frameless Stereotactic Body Radiotherapy for Lung Cancer Using Four- Dimensional Cone Beam CT Guidance. International journal of radiation oncology, biology, physics 74, Khan, F. M., and Stathak, S. (010). The Physics of Radiation Therapy. Medical Physics 37, Mattes, D., Haynor, D. R., Vesselle, H., Lewellen, T. K., and Eubank, W. (003). PET-CT image regtration in the chest using free-form deformations. Medical Imaging, IEEE Transactions on, Nithiananthan, S., Brock, K. K., Daly, M. J., Chan, H., Irh, J. C., and Siewerdsen, J. H. (009). Demons deformable regtration for CBCT-guided procedures in the head and neck: Convergence and accuracy. Medical Physics 36, Noel, C. E., and et al. (010). An automated method for adaptive radiation therapy for prostate cancer patients using continuous fiducial-based tracking. Physics in Medicine and Biology 55, Østergaard Noe, K., De Senneville, B. D., Elstrøm, U. V., Tanderup, K., and Sørensen, T. S. (008). Acceleration and validation of optical flow based deformable regtration for image-guided radiotherapy. Acta Oncologica 47, Paquin, D., Levy, D., and Xing, L. (009). Multcale regtration of planning CT and daily cone beam CT images for adaptive radiation therapy. Medical Physics 36, Stanton, R., Stinson, D., and Mihailid, D. (010). Applied Physics for Radiation Oncology, Reved Edition. Medical Physics 37, Lu, W., and et al. (006). Deformable regtration of the planning image (kvct) and the daily images (MVCT) for adaptive radiation therapy. Physics in Medicine and Biology 51,

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT Anand P Santhanam Assistant Professor, Department of Radiation Oncology OUTLINE Adaptive radiotherapy for head and

More information

VALIDATION OF DIR. Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology

VALIDATION OF DIR. Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology VALIDATION OF DIR Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology Overview Basics: Registration Framework, Theory Discuss Validation techniques Using Synthetic CT data & Phantoms What metrics to

More information

ADVANCING CANCER TREATMENT

ADVANCING CANCER TREATMENT 3 ADVANCING CANCER TREATMENT SUPPORTING CLINICS WORLDWIDE RaySearch is advancing cancer treatment through pioneering software. We believe software has un limited potential, and that it is now the driving

More information

Auto-Segmentation Using Deformable Image Registration. Disclosure. Objectives 8/4/2011

Auto-Segmentation Using Deformable Image Registration. Disclosure. Objectives 8/4/2011 Auto-Segmentation Using Deformable Image Registration Lei Dong, Ph.D. Dept. of Radiation Physics University of Texas MD Anderson Cancer Center, Houston, Texas AAPM Therapy Educational Course Aug. 4th 2011

More information

ADVANCING CANCER TREATMENT

ADVANCING CANCER TREATMENT The RayPlan treatment planning system makes proven, innovative RayStation technology accessible to clinics that need a cost-effective and streamlined solution. Fast, efficient and straightforward to use,

More information

Use of Deformable Image Registration in Radiation Therapy. Colin Sims, M.Sc. Accuray Incorporated 1

Use of Deformable Image Registration in Radiation Therapy. Colin Sims, M.Sc. Accuray Incorporated 1 Use of Deformable Image Registration in Radiation Therapy Colin Sims, M.Sc. Accuray Incorporated 1 Overview of Deformable Image Registration (DIR) Algorithms that can deform one dataset to another have

More information

Is deformable image registration a solved problem?

Is deformable image registration a solved problem? Is deformable image registration a solved problem? Marcel van Herk On behalf of the imaging group of the RT department of NKI/AVL Amsterdam, the Netherlands DIR 1 Image registration Find translation.deformation

More information

Hybrid multiscale registration of planning CT images and daily CBCT images for adaptive and image-guided radiation therapy

Hybrid multiscale registration of planning CT images and daily CBCT images for adaptive and image-guided radiation therapy Hybrid multiscale registration of planning CT images and daily CBCT images for adaptive and image-guided radiation therapy Dana Paquin, Doron Levy, and Lei Xing May 10, 2007 Abstract Adaptive radiation

More information

Hybrid Spline-based Multimodal Registration using a Local Measure for Mutual Information

Hybrid Spline-based Multimodal Registration using a Local Measure for Mutual Information Hybrid Spline-based Multimodal Registration using a Local Measure for Mutual Information Andreas Biesdorf 1, Stefan Wörz 1, Hans-Jürgen Kaiser 2, Karl Rohr 1 1 University of Heidelberg, BIOQUANT, IPMB,

More information

GPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC

GPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC GPU applications in Cancer Radiation Therapy at UCSD Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC Conventional Radiotherapy SIMULATION: Construciton, Dij Days PLANNING:

More information

radiotherapy Andrew Godley, Ergun Ahunbay, Cheng Peng, and X. Allen Li NCAAPM Spring Meeting 2010 Madison, WI

radiotherapy Andrew Godley, Ergun Ahunbay, Cheng Peng, and X. Allen Li NCAAPM Spring Meeting 2010 Madison, WI GPU-Accelerated autosegmentation for adaptive radiotherapy Andrew Godley, Ergun Ahunbay, Cheng Peng, and X. Allen Li agodley@mcw.edu NCAAPM Spring Meeting 2010 Madison, WI Overview Motivation Adaptive

More information

Good Morning! Thank you for joining us

Good Morning! Thank you for joining us Good Morning! Thank you for joining us Deformable Registration, Contour Propagation and Dose Mapping: 101 and 201 Marc Kessler, PhD, FAAPM The University of Michigan Conflict of Interest I receive direct

More information

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT CLINICAL COMMISSIONING AND ACCEPTANCE TESTING OF A 3D SURFACE MATCHING SYSTEM Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago Learning Objective Describe acceptance

More information

Image Guidance and Beam Level Imaging in Digital Linacs

Image Guidance and Beam Level Imaging in Digital Linacs Image Guidance and Beam Level Imaging in Digital Linacs Ruijiang Li, Ph.D. Department of Radiation Oncology Stanford University School of Medicine 2014 AAPM Therapy Educational Course Disclosure Research

More information

Implementation of Advanced Image Guided Radiation Therapy

Implementation of Advanced Image Guided Radiation Therapy Image Acquisition Course Outline Principles, characteristics& applications of the available modalities Image Processing in the T x room Image guided treatment delivery What can / can t we do in the room

More information

A Non-Linear Image Registration Scheme for Real-Time Liver Ultrasound Tracking using Normalized Gradient Fields

A Non-Linear Image Registration Scheme for Real-Time Liver Ultrasound Tracking using Normalized Gradient Fields A Non-Linear Image Registration Scheme for Real-Time Liver Ultrasound Tracking using Normalized Gradient Fields Lars König, Till Kipshagen and Jan Rühaak Fraunhofer MEVIS Project Group Image Registration,

More information

8/3/2017. Contour Assessment for Quality Assurance and Data Mining. Objective. Outline. Tom Purdie, PhD, MCCPM

8/3/2017. Contour Assessment for Quality Assurance and Data Mining. Objective. Outline. Tom Purdie, PhD, MCCPM Contour Assessment for Quality Assurance and Data Mining Tom Purdie, PhD, MCCPM Objective Understand the state-of-the-art in contour assessment for quality assurance including data mining-based techniques

More information

Overview of Proposed TG-132 Recommendations

Overview of Proposed TG-132 Recommendations Overview of Proposed TG-132 Recommendations Kristy K Brock, Ph.D., DABR Associate Professor Department of Radiation Oncology, University of Michigan Chair, AAPM TG 132: Image Registration and Fusion Conflict

More information

8/3/2016. Image Guidance Technologies. Introduction. Outline

8/3/2016. Image Guidance Technologies. Introduction. Outline 8/3/26 Session: Image Guidance Technologies and Management Strategies Image Guidance Technologies Jenghwa Chang, Ph.D.,2 Department of Radiation Medicine, Northwell Health 2 Hofstra Northwell School of

More information

Landmark-based 3D Elastic Registration of Pre- and Postoperative Liver CT Data

Landmark-based 3D Elastic Registration of Pre- and Postoperative Liver CT Data Landmark-based 3D Elastic Registration of Pre- and Postoperative Liver CT Data An Experimental Comparison Thomas Lange 1, Stefan Wörz 2, Karl Rohr 2, Peter M. Schlag 3 1 Experimental and Clinical Research

More information

Deformable Segmentation using Sparse Shape Representation. Shaoting Zhang

Deformable Segmentation using Sparse Shape Representation. Shaoting Zhang Deformable Segmentation using Sparse Shape Representation Shaoting Zhang Introduction Outline Our methods Segmentation framework Sparse shape representation Applications 2D lung localization in X-ray 3D

More information

Clinical Prospects and Technological Challenges for Multimodality Imaging Applications in Radiotherapy Treatment Planning

Clinical Prospects and Technological Challenges for Multimodality Imaging Applications in Radiotherapy Treatment Planning Clinical Prospects and Technological Challenges for Multimodality Imaging Applications in Radiotherapy Treatment Planning Issam El Naqa, PhD Assistant Professor Department of Radiation Oncology Washington

More information

Tomographic Reconstruction

Tomographic Reconstruction Tomographic Reconstruction 3D Image Processing Torsten Möller Reading Gonzales + Woods, Chapter 5.11 2 Overview Physics History Reconstruction basic idea Radon transform Fourier-Slice theorem (Parallel-beam)

More information

Head and Neck Lymph Node Region Delineation with Auto-segmentation and Image Registration

Head and Neck Lymph Node Region Delineation with Auto-segmentation and Image Registration Head and Neck Lymph Node Region Delineation with Auto-segmentation and Image Registration Chia-Chi Teng Department of Electrical Engineering University of Washington 1 Outline Introduction Related Work

More information

Interactive Deformable Registration Visualization and Analysis of 4D Computed Tomography

Interactive Deformable Registration Visualization and Analysis of 4D Computed Tomography Interactive Deformable Registration Visualization and Analysis of 4D Computed Tomography Burak Erem 1, Gregory C. Sharp 2, Ziji Wu 2, and David Kaeli 1 1 Department of Electrical and Computer Engineering,

More information

Optimization of Image Guided Radiation Therapy Using. Limited Angle Projections

Optimization of Image Guided Radiation Therapy Using. Limited Angle Projections Optimization of Image Guided Radiation Therapy Using Limited Angle Projections by Lei Ren Medical Physics Graduate Program Duke University Date: Approved: Fang-Fang Yin, Supervisor Shiva K. Das Q. Jackie

More information

Finite Element Simulation of Moving Targets in Radio Therapy

Finite Element Simulation of Moving Targets in Radio Therapy Finite Element Simulation of Moving Targets in Radio Therapy Pan Li, Gregor Remmert, Jürgen Biederer, Rolf Bendl Medical Physics, German Cancer Research Center, 69120 Heidelberg Email: pan.li@dkfz.de Abstract.

More information

8/4/2016. Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery. Disclosure. Introduction: Treatment delivery techniques

8/4/2016. Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery. Disclosure. Introduction: Treatment delivery techniques Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery Lei Ren, Ph.D. Duke University Medical Center 2016 AAPM 58 th annual meeting, Educational Course, Therapy Track Disclosure I have

More information

GPU-based Fast Cone Beam CT Reconstruction from Undersampled and Noisy Projection Data via Total Variation

GPU-based Fast Cone Beam CT Reconstruction from Undersampled and Noisy Projection Data via Total Variation GPU-based Fast Cone Beam CT Reconstruction from Undersampled and Noisy Projection Data via Total Variation 5 10 15 20 25 30 35 Xun Jia Department of Radiation Oncology, University of California San Diego,

More information

Virtual Phantoms for IGRT QA

Virtual Phantoms for IGRT QA TM Virtual Phantoms for IGRT QA Why ImSimQA? ImSimQA was developed to overcome the limitations of physical phantoms for testing modern medical imaging and radiation therapy software systems, when there

More information

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram TomoTherapy Related Projects An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram Development of A Novel Image Guidance Alternative for Patient Localization

More information

Automated segmentation methods for liver analysis in oncology applications

Automated segmentation methods for liver analysis in oncology applications University of Szeged Department of Image Processing and Computer Graphics Automated segmentation methods for liver analysis in oncology applications Ph. D. Thesis László Ruskó Thesis Advisor Dr. Antal

More information

A Duality Based Algorithm for TV-L 1 -Optical-Flow Image Registration

A Duality Based Algorithm for TV-L 1 -Optical-Flow Image Registration A Duality Based Algorithm for TV-L 1 -Optical-Flow Image Registration Thomas Pock 1, Martin Urschler 1, Christopher Zach 2, Reinhard Beichel 3, and Horst Bischof 1 1 Institute for Computer Graphics & Vision,

More information

Intraoperative Prostate Tracking with Slice-to-Volume Registration in MR

Intraoperative Prostate Tracking with Slice-to-Volume Registration in MR Intraoperative Prostate Tracking with Slice-to-Volume Registration in MR Sean Gill a, Purang Abolmaesumi a,b, Siddharth Vikal a, Parvin Mousavi a and Gabor Fichtinger a,b,* (a) School of Computing, Queen

More information

CLARET: A Fast Deformable Registration Method Applied to Lung Radiation Therapy

CLARET: A Fast Deformable Registration Method Applied to Lung Radiation Therapy Fourth International Workshop on Pulmonary Image Analysis -113- CLARET: A Fast Deformable Registration Method Applied to Lung Radiation Therapy Chen-Rui Chou 1, Brandon Frederick 2, Xiaoxiao Liu 4, Gig

More information

1. Learn to incorporate QA for surface imaging

1. Learn to incorporate QA for surface imaging Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago ***No disclosures*** 1. Learn to incorporate QA for surface imaging into current QA procedures for IGRT. 2. Understand

More information

Automatic Segmentation of Parotids from CT Scans Using Multiple Atlases

Automatic Segmentation of Parotids from CT Scans Using Multiple Atlases Automatic Segmentation of Parotids from CT Scans Using Multiple Atlases Jinzhong Yang, Yongbin Zhang, Lifei Zhang, and Lei Dong Department of Radiation Physics, University of Texas MD Anderson Cancer Center

More information

arxiv: v1 [cs.cv] 6 Jun 2017

arxiv: v1 [cs.cv] 6 Jun 2017 Volume Calculation of CT lung Lesions based on Halton Low-discrepancy Sequences Liansheng Wang a, Shusheng Li a, and Shuo Li b a Department of Computer Science, Xiamen University, Xiamen, China b Dept.

More information

TG 132: Use of Image Registration and Fusion in RT

TG 132: Use of Image Registration and Fusion in RT TG 132: Use of Image Registration and Fusion in RT Kristy K Brock, PhD, DABR, FAAPM Associate Professor Department of Radiation Oncology, University of Michigan Chair, AAPM TG 132: Image Registration and

More information

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT Volumetric Modulated Arc Therapy - Clinical Implementation Daliang Cao, PhD, DABR Swedish Cancer Institute, Seattle, WA Acknowledgement David M. Shepard, Ph.D. Muhammad K. N. Afghan, Ph.D. Fan Chen, Ph.D.

More information

Automated Quality Assurance for Image-Guided Radiation Therapy

Automated Quality Assurance for Image-Guided Radiation Therapy JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 10, NUMBER 1, WINTER 2009 Automated Quality Assurance for Image-Guided Radiation Therapy Eduard Schreibmann, a Eric Elder, Tim Fox Department of Radiation

More information

2 Michael E. Leventon and Sarah F. F. Gibson a b c d Fig. 1. (a, b) Two MR scans of a person's knee. Both images have high resolution in-plane, but ha

2 Michael E. Leventon and Sarah F. F. Gibson a b c d Fig. 1. (a, b) Two MR scans of a person's knee. Both images have high resolution in-plane, but ha Model Generation from Multiple Volumes using Constrained Elastic SurfaceNets Michael E. Leventon and Sarah F. F. Gibson 1 MIT Artificial Intelligence Laboratory, Cambridge, MA 02139, USA leventon@ai.mit.edu

More information

HYBRID MULTISCALE LANDMARK AND DEFORMABLE IMAGE REGISTRATION. Dana Paquin. Doron Levy. Lei Xing. (Communicated by Yang Kuang)

HYBRID MULTISCALE LANDMARK AND DEFORMABLE IMAGE REGISTRATION. Dana Paquin. Doron Levy. Lei Xing. (Communicated by Yang Kuang) MATHEMATICAL BIOSCIENCES http://www.mbejournal.org/ AND ENGINEERING Volume 4, Number 4, October 2007 pp. 711 737 HYBRID MULTISCALE LANDMARK AND DEFORMABLE IMAGE REGISTRATION Dana Paquin Department of Mathematics,

More information

Non-Rigid Image Registration III

Non-Rigid Image Registration III Non-Rigid Image Registration III CS6240 Multimedia Analysis Leow Wee Kheng Department of Computer Science School of Computing National University of Singapore Leow Wee Kheng (CS6240) Non-Rigid Image Registration

More information

7/29/2017. Making Better IMRT Plans Using a New Direct Aperture Optimization Approach. Aim of Radiotherapy Research. Aim of Radiotherapy Research

7/29/2017. Making Better IMRT Plans Using a New Direct Aperture Optimization Approach. Aim of Radiotherapy Research. Aim of Radiotherapy Research Making Better IMRT Plans Using a New Direct Aperture Optimization Approach Dan Nguyen, Ph.D. Division of Medical Physics and Engineering Department of Radiation Oncology UT Southwestern AAPM Annual Meeting

More information

Non-rigid Image Registration

Non-rigid Image Registration Overview Non-rigid Image Registration Introduction to image registration - he goal of image registration - Motivation for medical image registration - Classification of image registration - Nonrigid registration

More information

Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No.

Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132 Kristy K. Brock a) Department of Imaging Physics, The University

More information

Image Registration. Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department

Image Registration. Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department Image Registration Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department Introduction Visualize objects inside the human body Advances in CS methods to diagnosis, treatment planning and medical

More information

Image Co-Registration II: TG132 Quality Assurance for Image Registration. Image Co-Registration II: TG132 Quality Assurance for Image Registration

Image Co-Registration II: TG132 Quality Assurance for Image Registration. Image Co-Registration II: TG132 Quality Assurance for Image Registration Image Co-Registration II: TG132 Quality Assurance for Image Registration Preliminary Recommendations from TG 132* Kristy Brock, Sasa Mutic, Todd McNutt, Hua Li, and Marc Kessler *Recommendations are NOT

More information

Radiation therapy treatment plan optimization

Radiation therapy treatment plan optimization H. Department of Industrial and Operations Engineering The University of Michigan, Ann Arbor, Michigan MOPTA Lehigh University August 18 20, 2010 Outline 1 Introduction Radiation therapy delivery 2 Treatment

More information

Digital Tomosynthesis for Target Localization

Digital Tomosynthesis for Target Localization Digital Tomosynthesis for Target Localization Fang-Fang Yin, Devon Godfrey, Lei Ren Jacqueline Maurer, Jackie Q-L Wu Duke University Medical Center Acknowledgements Duke Radiation Oncology faculty and

More information

Volumetric Cine Imaging for On-board Target Localization in Radiation Therapy. Wendy Beth Harris. Graduate Program in Medical Physics Duke University

Volumetric Cine Imaging for On-board Target Localization in Radiation Therapy. Wendy Beth Harris. Graduate Program in Medical Physics Duke University Volumetric Cine Imaging for On-board Target Localization in Radiation Therapy by Wendy Beth Harris Graduate Program in Medical Physics Duke University Date: Approved: Lei Ren, Supervisor Fang-Fang Yin,

More information

Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT

Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT Marcus Brehm 1,2, Thorsten Heußer 1, Pascal Paysan 3, Markus Oehlhafen 3, and Marc Kachelrieß 1,2 1 German Cancer Research Center

More information

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy Dana Paquin Department of Mathematics, California Polytechnic State University, San Luis Obispo, California

More information

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator Andrew J Reilly Imaging Physicist Oncology Physics Edinburgh Cancer Centre Western General Hospital EDINBURGH EH4

More information

Using Probability Maps for Multi organ Automatic Segmentation

Using Probability Maps for Multi organ Automatic Segmentation Using Probability Maps for Multi organ Automatic Segmentation Ranveer Joyseeree 1,2, Óscar Jiménez del Toro1, and Henning Müller 1,3 1 University of Applied Sciences Western Switzerland (HES SO), Sierre,

More information

A learning-based patient repositioning method from limited-angle projections

A learning-based patient repositioning method from limited-angle projections A learning-based patient repositioning method from limited-angle projections Chen-Rui Chou 1, C. Brandon Frederick 2, Sha Chang 3, and Stephen M. Pizer 1,2,3 1 Department of Computer Science, UNC-Chapel

More information

Current state of multi-criteria treatment planning

Current state of multi-criteria treatment planning Current state of multi-criteria treatment planning June 11, 2010 Fall River NE AAPM meeting David Craft Massachusetts General Hospital Talk outline - Overview of optimization - Multi-criteria optimization

More information

Fast CT-CT Fluoroscopy Registration with Respiratory Motion Compensation for Image-Guided Lung Intervention

Fast CT-CT Fluoroscopy Registration with Respiratory Motion Compensation for Image-Guided Lung Intervention Fast CT-CT Fluoroscopy Registration with Respiratory Motion Compensation for Image-Guided Lung Intervention Po Su a,b, Zhong Xue b*, Kongkuo Lu c, Jianhua Yang a, Stephen T. Wong b a School of Automation,

More information

Lucy Phantom MR Grid Evaluation

Lucy Phantom MR Grid Evaluation Lucy Phantom MR Grid Evaluation Anil Sethi, PhD Loyola University Medical Center, Maywood, IL 60153 November 2015 I. Introduction: The MR distortion grid, used as an insert with Lucy 3D QA phantom, is

More information

Creating a Knowledge Based Model using RapidPlan TM : The Henry Ford Experience

Creating a Knowledge Based Model using RapidPlan TM : The Henry Ford Experience DVH Estimates Creating a Knowledge Based Model using RapidPlan TM : The Henry Ford Experience Karen Chin Snyder, MS, DABR AAMD Region V Meeting October 4, 2014 Disclosures The Department of Radiation Oncology

More information

Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems

Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems University of Wollongong Research Online Faculty of Engineering and Information Sciences - Papers: Part A Faculty of Engineering and Information Sciences 2015 Evaluation of 3D Gamma index calculation implemented

More information

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon WHITE PAPER Introduction An image guidance system based on Cone Beam CT (CBCT) is included in Leksell

More information

Non-Rigid Multimodal Medical Image Registration using Optical Flow and Gradient Orientation

Non-Rigid Multimodal Medical Image Registration using Optical Flow and Gradient Orientation M. HEINRICH et al.: MULTIMODAL REGISTRATION USING GRADIENT ORIENTATION 1 Non-Rigid Multimodal Medical Image Registration using Optical Flow and Gradient Orientation Mattias P. Heinrich 1 mattias.heinrich@eng.ox.ac.uk

More information

iplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration

iplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration iplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration The iplan Contouring Workstation offers unique and innovative capabilities for faster contouring and consistent segmentation

More information

Deformable Image Registration, Contour Propagation and Dose Mapping: 101 and 201. Please do not (re)redistribute

Deformable Image Registration, Contour Propagation and Dose Mapping: 101 and 201. Please do not (re)redistribute Deformable Registration, Contour Deformable Registration, Contour Propagation and Dose Mapping: 101 and 201 Marc Kessler, PhD The University of Michigan Jean Pouliot, PhD University of California Learning

More information

Tumor motion during liver SBRT

Tumor motion during liver SBRT Tumor motion during liver SBRT - projects at Aarhus University Hospital - Per Poulsen, Esben Worm, Walther Fledelius, Morten Høyer Aarhus University Hospital, Denmark SBRT: Stereotactic Body Radiation

More information

GPU-based fast gamma index calcuation

GPU-based fast gamma index calcuation 1 GPU-based fast gamma index calcuation 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Xuejun Gu, Xun Jia, and Steve B. Jiang Center for Advanced Radiotherapy Technologies

More information

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon WHITE PAPER Introduction Introducing an image guidance system based on Cone Beam CT (CBCT) and a mask immobilization

More information

Brilliance CT Big Bore.

Brilliance CT Big Bore. 1 2 2 There are two methods of RCCT acquisition in widespread clinical use: cine axial and helical. In RCCT with cine axial acquisition, repeat CT images are taken each couch position while recording respiration.

More information

Atlas Based Segmentation of the prostate in MR images

Atlas Based Segmentation of the prostate in MR images Atlas Based Segmentation of the prostate in MR images Albert Gubern-Merida and Robert Marti Universitat de Girona, Computer Vision and Robotics Group, Girona, Spain {agubern,marly}@eia.udg.edu Abstract.

More information

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588 ICARO Vienna April 27-29 2009 Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588 M. Saiful Huq, Ph.D., Professor and Director, Dept. of Radiation

More information

Prostate Detection Using Principal Component Analysis

Prostate Detection Using Principal Component Analysis Prostate Detection Using Principal Component Analysis Aamir Virani (avirani@stanford.edu) CS 229 Machine Learning Stanford University 16 December 2005 Introduction During the past two decades, computed

More information

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC New Technology in Radiation Oncology James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC Technology s s everywhere From the imaging chain To the planning system To the linac To QA..it..it

More information

Estimating 3D Respiratory Motion from Orbiting Views

Estimating 3D Respiratory Motion from Orbiting Views Estimating 3D Respiratory Motion from Orbiting Views Rongping Zeng, Jeffrey A. Fessler, James M. Balter The University of Michigan Oct. 2005 Funding provided by NIH Grant P01 CA59827 Motivation Free-breathing

More information

Nonrigid Registration Using a Rigidity Constraint

Nonrigid Registration Using a Rigidity Constraint Nonrigid Registration Using a Rigidity Constraint Marius Staring, Stefan Klein and Josien P.W. Pluim Image Sciences Institute, University Medical Center Utrecht, P.O. Box 85500, 3508 GA, Room Q0S.459,

More information

Nonrigid Registration using Free-Form Deformations

Nonrigid Registration using Free-Form Deformations Nonrigid Registration using Free-Form Deformations Hongchang Peng April 20th Paper Presented: Rueckert et al., TMI 1999: Nonrigid registration using freeform deformations: Application to breast MR images

More information

1. INTRODUCTION ABSTRACT

1. INTRODUCTION ABSTRACT Incorporating Tissue Excision in Deformable Image Registration: A Modified Demons Algorithm for Cone-Beam CT-Guided Surgery S.Nithiananthan, a D. Mirota, b A. Uneri, b S. Schafer, a Y. Otake, b J.W. Stayman,

More information

Mech. Engineering, Comp. Science, and Rad. Oncology Departments. Schools of Engineering and Medicine, Bio-X Program, Stanford University

Mech. Engineering, Comp. Science, and Rad. Oncology Departments. Schools of Engineering and Medicine, Bio-X Program, Stanford University Mech. Engineering, Comp. Science, and Rad. Oncology Departments Schools of Engineering and Medicine, Bio-X Program, Stanford University 1 Conflict of Interest Nothing to disclose 2 Imaging During Beam

More information

ROBUST OPTIMIZATION THE END OF PTV AND THE BEGINNING OF SMART DOSE CLOUD. Moe Siddiqui, April 08, 2017

ROBUST OPTIMIZATION THE END OF PTV AND THE BEGINNING OF SMART DOSE CLOUD. Moe Siddiqui, April 08, 2017 ROBUST OPTIMIZATION THE END OF PTV AND THE BEGINNING OF SMART DOSE CLOUD Moe Siddiqui, April 08, 2017 Agenda Background IRCU 50 - Disclaimer - Uncertainties Robust optimization Use Cases Lung Robust 4D

More information

RADIOMICS: potential role in the clinics and challenges

RADIOMICS: potential role in the clinics and challenges 27 giugno 2018 Dipartimento di Fisica Università degli Studi di Milano RADIOMICS: potential role in the clinics and challenges Dr. Francesca Botta Medical Physicist Istituto Europeo di Oncologia (Milano)

More information

Cluster of Workstation based Nonrigid Image Registration Using Free-Form Deformation

Cluster of Workstation based Nonrigid Image Registration Using Free-Form Deformation Cluster of Workstation based Nonrigid Image Registration Using Free-Form Deformation Xiaofen Zheng, Jayaram K. Udupa, and Xinjian Chen Medical Image Processing Group, Department of Radiology 423 Guardian

More information

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING Reveal pathology Reveal the anatomic truth Steven R. Singer, DDS srs2@columbia.edu IDEAL DIAGNOSTIC IMAGING STUDY Provides desired diagnostic

More information

Modeling and preoperative planning for kidney surgery

Modeling and preoperative planning for kidney surgery Modeling and preoperative planning for kidney surgery Refael Vivanti Computer Aided Surgery and Medical Image Processing Lab Hebrew University of Jerusalem, Israel Advisor: Prof. Leo Joskowicz Clinical

More information

Weakly Supervised Fully Convolutional Network for PET Lesion Segmentation

Weakly Supervised Fully Convolutional Network for PET Lesion Segmentation Weakly Supervised Fully Convolutional Network for PET Lesion Segmentation S. Afshari a, A. BenTaieb a, Z. Mirikharaji a, and G. Hamarneh a a Medical Image Analysis Lab, School of Computing Science, Simon

More information

Nonrigid Registration with Adaptive, Content-Based Filtering of the Deformation Field

Nonrigid Registration with Adaptive, Content-Based Filtering of the Deformation Field Nonrigid Registration with Adaptive, Content-Based Filtering of the Deformation Field Marius Staring*, Stefan Klein and Josien P.W. Pluim Image Sciences Institute, University Medical Center Utrecht, P.O.

More information

Analysis of Dose Calculation Accuracy in Cone Beam Computed Tomography with Various Amount of Scattered Photon Contamination

Analysis of Dose Calculation Accuracy in Cone Beam Computed Tomography with Various Amount of Scattered Photon Contamination International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 2017, 6, 233-251 http://www.scirp.org/journal/ijmpcero ISSN Online: 2168-5444 ISSN Print: 2168-5436 Analysis of Dose

More information

Advanced Targeting Using Image Deformation. Justin Keister, MS DABR Aurora Health Care Kenosha, WI

Advanced Targeting Using Image Deformation. Justin Keister, MS DABR Aurora Health Care Kenosha, WI Advanced Targeting Using Image Deformation Justin Keister, MS DABR Aurora Health Care Kenosha, WI History of Targeting The advance of IMRT and CT simulation has changed how targets are identified in radiation

More information

Medical Image Registration by Maximization of Mutual Information

Medical Image Registration by Maximization of Mutual Information Medical Image Registration by Maximization of Mutual Information EE 591 Introduction to Information Theory Instructor Dr. Donald Adjeroh Submitted by Senthil.P.Ramamurthy Damodaraswamy, Umamaheswari Introduction

More information

The team. Disclosures. Ultrasound Guidance During Radiation Delivery: Confronting the Treatment Interference Challenge.

The team. Disclosures. Ultrasound Guidance During Radiation Delivery: Confronting the Treatment Interference Challenge. Ultrasound Guidance During Radiation Delivery: Confronting the Treatment Interference Challenge Dimitre Hristov Radiation Oncology Stanford University The team Renhui Gong 1 Magdalena Bazalova-Carter 1

More information

The Insight Toolkit. Image Registration Algorithms & Frameworks

The Insight Toolkit. Image Registration Algorithms & Frameworks The Insight Toolkit Image Registration Algorithms & Frameworks Registration in ITK Image Registration Framework Multi Resolution Registration Framework Components PDE Based Registration FEM Based Registration

More information

Op#miza#on of an On- Board Imaging System for Rapid Radiotherapy. Erica Kemmerling, Meng Wu, He Yang, and Rebecca Fahrig

Op#miza#on of an On- Board Imaging System for Rapid Radiotherapy. Erica Kemmerling, Meng Wu, He Yang, and Rebecca Fahrig Op#miza#on of an On- Board Imaging System for Rapid Radiotherapy Erica Kemmerling, Meng Wu, He Yang, and Rebecca Fahrig Problem: mo#on during treatment Two overlapping thorax views during normal breathing

More information

Free Form Deformations Guided by Gradient Vector Flow: a Surface Registration Method in Thoracic and Abdominal PET-CT Applications

Free Form Deformations Guided by Gradient Vector Flow: a Surface Registration Method in Thoracic and Abdominal PET-CT Applications Free Form Deformations Guided by Gradient Vector Flow: a Surface Registration Method in Thoracic and Abdominal PET-CT Applications Oscar Camara, Gaspar Delso, and Isabelle Bloch Ecole Nationale Supérieure

More information

Interactive Treatment Planning in Cancer Radiotherapy

Interactive Treatment Planning in Cancer Radiotherapy Interactive Treatment Planning in Cancer Radiotherapy Mohammad Shakourifar Giulio Trigila Pooyan Shirvani Ghomi Abraham Abebe Sarah Couzens Laura Noreña Wenling Shang June 29, 212 1 Introduction Intensity

More information

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA Spiral CT Protocol Optimization & Quality Assurance Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA Spiral CT Protocol Optimization & Quality Assurance Protocol optimization

More information

2D Rigid Registration of MR Scans using the 1d Binary Projections

2D Rigid Registration of MR Scans using the 1d Binary Projections 2D Rigid Registration of MR Scans using the 1d Binary Projections Panos D. Kotsas Abstract This paper presents the application of a signal intensity independent registration criterion for 2D rigid body

More information

A Generation Methodology for Numerical Phantoms with Statistically Relevant Variability of Geometric and Physical Properties

A Generation Methodology for Numerical Phantoms with Statistically Relevant Variability of Geometric and Physical Properties A Generation Methodology for Numerical Phantoms with Statistically Relevant Variability of Geometric and Physical Properties Steven Dolly 1, Eric Ehler 1, Yang Lou 2, Mark Anastasio 2, Hua Li 2 (1) University

More information

Shading correction algorithm for cone-beam CT in radiotherapy: Extensive clinical validation of image quality improvement

Shading correction algorithm for cone-beam CT in radiotherapy: Extensive clinical validation of image quality improvement Shading correction algorithm for cone-beam CT in radiotherapy: Extensive clinical validation of image quality improvement K D Joshi a, T E Marchant b, a, and C J Moore b, a a Christie Medical Physics and

More information

Response to Reviewers

Response to Reviewers Response to Reviewers We thank the reviewers for their feedback and have modified the manuscript and expanded results accordingly. There have been several major revisions to the manuscript. First, we have

More information

SIGMI Meeting ~Image Fusion~ Computer Graphics and Visualization Lab Image System Lab

SIGMI Meeting ~Image Fusion~ Computer Graphics and Visualization Lab Image System Lab SIGMI Meeting ~Image Fusion~ Computer Graphics and Visualization Lab Image System Lab Introduction Medical Imaging and Application CGV 3D Organ Modeling Model-based Simulation Model-based Quantification

More information