Imaging in Radio-Oncology :

Size: px
Start display at page:

Download "Imaging in Radio-Oncology :"

Transcription

1 Imaging in Radio-Oncology : Sometimes imaging = miraging Can you find the position of the camels? PD Dr Jean-François Germond SSRMP Medical Physicist Service de radiothérapie du DPO La Chaux-de-Fonds FMH resident physics training course in RO, PSI, 3/09/2007 Objectives Usage of imaging in medicine 1/2 1. Historical introduction 2. Anatomical imaging in RO localization 3. Functional imaging in RO localization 4. Immersion into 3D 5. 4D imaging in RO localization 6. Virtual simulation imaging 7. 3D guidance imaging Mechanical Waves Sound Ultrasound EM Potentials Biological Signals Medical imaging All types of waves Infrared Radio- Waves Magnet. Reson. Electromagnetic Waves Thermography E-Mgraphy Echography Stethoscopy Endoscopy Light Radiography X Rays Scintigraphy g Rays Low energies High energies Usage of imaging in medicine 2/2 Historical evolution of imaging in RO 4D CT Well established in diagnostic Extensively used for tumor detection and staging Used throughout radio-oncology: for planning for irradiation Reference imaging CT PET-CT MRI for verification Simulator Cone beam 1960 Portal imaging Guidance imaging 1

2 Multimodal imaging Intensity modulation Virtual simulation Image guidance Block Imaging in conventional simulation 1/4 Imaging in conventional simulation 2/4 Therapy table Collimator X-Ray tube Simulated beam Digital camera Conventional simulator 1960 Width jaw Height jaw Block Simulator radiographs are used for drawing beams aperture Only based on D Bony structures Air cavities Contrast agent in specific organs Only 2D D Imaging in conventional simulation 3/4 Verification by portal film Imaging in conventional simulation 4/4 Still in use for palliative treatments => 30% of patients Still in use for pre-treatment verification of ports Reference image = Simulator image Portal film or electronic image used for verification Simulation film Verification film The 4 cornerstones of modern radio-oncology Features of imaging in RO Workflow 1. RO is image guided (IGRT) in three aspects: a. For the definition of volumes during planning (localization). Years3/4 of workflow 80 is imaging Years 2000 b. For the setup of fields in simulation (virtual simulation). c. For the verification of the ballistic during treatment (guidance). 2. Imaging for RO is multimodal (CT,MRI, PET, ) 3. Images RO must be stored, transferred and linked (DICOM) Years 2000 Years 90 2

3 Paradigm of target volumes definition GTV : Gross Tumor Volume CTV: ITV: PTV: ICRU 50 & 62 + subclinical envolvement + Internal margin + Setup margin GTV and CTV are oncological concepts based on a frozen anatomy Main issues of imaging in RO 1. Does the imaging modality allow to distinguish the target volume from its environment? Adjacent tissues with similar electronic densities in CT exams (atelectasy) 2. Does the imaging modality reflect the true anatomy? Artefacts 3. Does the image display allows the observer to perceive the target volume? JND index Definition: Visual perception of images The Just Noticeable Difference (JND) is the luminance difference that the average human observer can just perceive at a specified luminance level and viewing conditions Major steps in the RO workflow Localization Human eye is more sensitive in the low luminance range (Fechner law) Delineate in rooms with reduced ambient light (15-60 lux) 1 time Virtual simulation Guidance Irradiation DICOM GSDF conforming displays can compensate for this effect Dose planification Several times Major steps in the RO workflow Localization Virtual simulation Dose planification Guidance Irradiation Localization in RO Goal: Precisely define the position, shape and volume of organs Target (tumor, lymph nodes, tumor bed, ) At risk (spinal cord, lungs, bladder, rectum, ) Material: All 3D imaging modalities CT, MRI, PET, SPECT, MRS, Multimodalities registration and fusion Method: Organs delineation Manual contouring Automatic (thresholding, deformation, interpolation, atlas, ) 3

4 Anatomical imaging Information characteristics of imaging in RO Anatomical imaging Functional imaging => Structures and morphology => Biological and molecular abnormalities in tumors From Smith A. and K.S. Clifford Chao, Radiation Research, 2005 Paradigm of target volumes definition Historical evolution of imaging in RT 4D CT ICRU 50 & 62 GTV : Gross Tumor Volume CTV: + subclinical envolvement ITV: + Internal margin PTV: + Setup margin Reference imaging CT PET-CT MRI Anatomical imaging in RO is extensively used for delineating the GTV Simulator Cone beam Portal imaging 1960 Guidance imaging CT equipment for RO Mode of acquisition Large gantry aperture Movable lasers Acquisition in helical (spiral) mode Table shift over 360 rotation(d) Pitch Collimation length(l) Flat table top Software + protocols Axial scan Pitch = 1 d = 1 x L Pitch = 1.5 d = 1.5 x L Pitch = 2 d = 2 x L Artist view, courtesy of Philips Medical Systems Full sampling for 360 recontruction Full sampling for 180 recontruction More complex for multislices CT 4

5 CT data acquisition CT data acquisition Sinogram Gantry angle Transmission profile Transmission profile Reconstruction by backprojection Example of a point object Image quality Filtered Sinogram 15 The usefulness of images is affected by several of their characteristics: Artefacts Contrast Resolution Noise The image characteristics depend strongly on modalities. Transverse image D pretense of reality only! Image charateristics Artefacts CT Different structures seen PET Different structures seen Definition: An artefact is any visible structure which does not reflect the reality of the patient anatomy (wrong CT numbers) Artefacts may be patient related: a. Metallic objects inside the body (prothesis, clip, dental filling, ) b. Patient voluntary or involuntary motions Different resolution c. Field of view smaller than patient size (obese patients) Different noise From F. Schoenahl, Cours CFPFTRM,

6 HN Artefacts Example of streaks due to metal inside the patient: Artefacts Example of shifts due to metal taped to the skin: Double hip prothesis dental filling Workaround: Reduce pitch or use special protocols Skin markers used for breast tangential fields virtual simulation Reconstructed below the skin D Workaround: Use special non metallic skin markers Hounsfield scale Windowing Hounsfield numbers (HN) = Tissue absorption coefficients compared to water Tissue Water HN 1000* => Normalized scale Water Increase contrast by mapping to 256 greyscale (8 bits) Choice of the level (L) and the window (W) from definite protocols 3000 Os compact L/W : 1000, 2500 Bone window Foie Eau +4-4 Os spongieux Graisse Reins Pancréas Sang 1000 L/W : 50, 400 Mediastinal window 0 2 Exemple de la prostate à insérer Poumons L/W : -600, 1600 Pulmonary window Air Contrast adaptation L/W: 0, 1000, (range (full in range) ROI) HN profile 1000 Resolution and contrast Limited resolution at high constrast 100 (HN HN ) GTV Surrounding (40 ( 90)) Calcul : %Contrast 13% Dispay a full profile 2. Zoom in on VOI 3. Set L/W to average, range of VOI HN s Contrast Resolution at low constrast Object size in mm 6

7 Localization with MRI saggital slice Organ 2 Organ 1 Multiplanar views Partial volume effect Definition: The partial volume effect is the part of an organ which has a reduced constrast to finite extension in the cranio-caudal direction coronal slice Correct HN Slice thickness I worst resolution in cranio-caudal Reduced contrast Transverse slice Consequences: Partial volume effect Small objects like lymph nodes have too low contrast Organ borders can be blurred Organs delineation on CT 3-D paintbrush/eraser paradigm -GTV: Gross Tumor Volume (Target volume, ICRU 50) Example of fuzzy separation between right kidney and liver Transverse slice -Vessie - Rectum (Organs at risk, ICRU 50) Coronal reconstruction Historical evolution of imaging in RT 4D CT MRI equipment for RO Reference imaging CT MRI PET-CT Movable lasers Magnetic field Antenna 1990 Simulator 1980 Flat table top Movable table 1970 Cone beam 1960 Portal imaging Guidance imaging Courtesy of Philips Medical Systems 7

8 Image fusion Localization with MRI Localization with MRI Localization with MRI Y gradient during waiting phase Localization with MRI Freq. MRI technics of spatial acquisition Phase Y i Frequence X i Contrast by T-weighting Relaxation times measured by special sequences T1: Longitudinal = spin-lattice Specific to tissue types T2: Transverse = spin-spin z gradient 1. Excite one plane 2. Select one raw 3. Select one column X gradient during reading phase Freq. Prostate example Examples of MRI artefacts Better definition (apex) Need training in fine anatomy details (nerves, muscles, ) Different volumes D Black hole in dental filling Courtesy of HUG Distortion at field edges Courtesy of HUG Courtesy of HUG Fusion of images Modalities other than CT are mostly used as complementary in RT: Question: How to used them combined for localization? Answer: by 2 successive electronic manipulations: 1. Registration of the 2 sets of images by a) Rigid method (ex: chamfer matching) b) Deformable method (ex: mutual information) 2. Display of the registrered images: Overlay of the 2 sets into one combined data set (fusion) Contour delineation on one modality and report in the other Constrained delineation 8

9 Image fusion Image fusion Image fusion Image fusion iteration Image fusion Image fusion a) Rigid 3D registration Mathematics of rigid registration Finds the best rigid transformation between 2 modalities (chamfer matching for bones) Reference image I ref ( r) Chamfer matching algorithm CT data set MRI data set Contours of interest C N p p Bone( I ref ) 3 translations Image of the day I day (r) 3 rotations Cost function Change T 1 cost N ps N T : Isocenter shift I day ( T r ) Injected CT T2 weighted CHUV Minimal cost I day ( T min r) I ( r) ref b) Deformable 3D registration Display of 2 data sets by colors superposition Maximalize similarity measure (mutual information) CT data set MRI data set morphing HUG Example of CT- MRI prostate fusion: Usages: Manual registration Quick check of registration quality --- Indications: HUG Morphological changes HUG Respiratory movements x Rectum filling Display of 2 data sets by colors addition Modality 1: greycale mapped to RGB pink = (255,0,255) Modality 2: greycale mapped to RGB green = (0,255,0) Overlay on screen mapped to the sum of pixel intensities: Only modality 1 = pink Only modality 2 = green Identical : (255,0,255) + (0,255,0) = (255,255,255) = white Display of 2 data sets by B&W + color Example of PET- CT fusion: Usages: Assignement of CT segmentation to tumor Example of CT- CBCT fusion: Usages: Visualization of morphology changes Tumor flashing Localization CT in pink CBCT of the day in green Changes in rectum filling Image from S. Senan S and D. De Ruysscher, Oncology Hematology,

10 Functioning imaging Localization with MRI Localization with MRI Image fusion Localization with MRI HUG Display of 2 data sets side by side Example of CT- MRI prostate registration: HUG Organs delineation on CT - MRI Example of prostate : HUG HUG Usages: Synchronized windows Sharing cursor Simultaneous delineation MRI data set From J. Dipascale et al., SASRO meeting,geneva, 2004 CT data set Organs delineation on CT - MRI Example of H&N : Organs delineation on CT - MRI Example between different institutions : CHUV 10/3/06 7/4/06 From Smith A. and K.S. Clifford Chao, Radiation Research, 2005 Time evolution of edema? Geometrical distortions? Adapt CTV margin Paradigm of target volumes definition ICRU 50 & 62 GTV : Gross Tumor Volume CTV: + subclinical envolvement ITV: + Internal margin PTV: + Setup margin Functional imaging in RO can be used for delineating the GTV and possibly the CTV 10

11 Localization with SPECT Localization with SPECT Localization with SPECT Localization with SPECT Localization with MRS Localization with MRS Dose maximalization MRS spectroscopy in gliomas Technics able to detect specific compounds of tissue other than water and fat (choline, creatine, N-AcetylAspartate) Gives information about the level of alteration of metabolites in tumor MRS spectroscopy in prostate High concentration of choline inside the prostate = tumor signature Used for dose painting Peak Cho >Cr and NAA in brain tumors REF Tumor [Chang, Med.Phys.06] SPECT equipment SPECT data acquisition Rotation Photo HNe Head 2 Gantry angle H&N mask system Head 1 Emission profile SPECT data acquisition SPECT data acquisition Sinogram Gantry angle Gantry angle Emission profile Emission profile 11

12 Localization with PET Localization with PET Localization with SPECT Localization with SPECT Localization with SPECT SPECT- CT fusion Organs delineation on SPECT - CT Example in H&N (Parathyroid Adenoma) : Example in glioma: Tc-mici Lenox Hill Hospital, NY Need specific calibration for quantitative use Recidive not seen on CT GTV delineated on mici captation volume SPECT GTV mapped to CT data set Perfusion segmentation on SPECT Historical evolution of imaging in RT 4D CT Perfusion withtc-99m High value of perfusion = lung zone OK Mc Guire et al. (2006) Reference imaging MRI PET-CT 2006 CT Simulator Cone beam Volume to spare in dose calculation 1960 Portal imaging Verification imaging PET gantry PET- CT equipment PET data acquisition Positron emission and annihilation ± movable lasers Sinogram Flat table top CT gantry Gantry angle Courtesy of Philips Medical Systems Emission profile 12

13 Localization with PET Localization with PET Localization with PET Localization with PET Localization with PET Localization with PET PET CT fusion Organs delineation on PET - CT Example of glioma: CHUV FDG But boundary depends on grey level intensities GTV? Source: R. Bridwell, PETLinQ, 2006 Topography of structures are difficult to localize on pure PET images but much easier to read on PET- CT fused images Cavity correctly mapped between PET and CT GTV delineated on CT correspond to FDG fixation Increase CTV to involve all the FDG fixation volume Standart Uptake Value (SUV) Semiquantitative index based on ROI values Comparison between PET and CT scales Example for lung tumors: Formula: SUV (Activity inroi / Volume of ROI) Injectedactivity / patientweight FDG SUV = 1 if radiotracer is uniformly distributed within the organism Calculation of SUV requires corrections for: Photons attenuation and scatter Organ motion Partial volume effect Present recommandations for GTV delineation are SUV > 2.5 SUV > 40% of maximum SUV But sites and D technics dependent Images from S. Senan S and D. De Ruysscher, Oncology Hematology, 2005 PET : CT : Standard Uptake Value SUV Houndsfield numbers HN Concentration of radiotracer Tissue absorption coefficients Scale: 0 to 14 Scale: to Organs delineation on PET - CT Example in oropharynx : Limitation of delineation on PET - CT Example for lung tumors: FDG CT SUV 40% SUV 2.5 D Corrections for the determination of radiotracer concentration (FDG) Images from U. Nestle et al., J. Nuclear Medicine, 2005 D Modelisation of the fixation metabolism (FDG different from glucose) From Smith A. and K.S. Clifford Chao, Radiation Research, 2005 D PET-CT is not yet the panacea for delineation 13

14 Localization in 3D Localization in 3D Localization in 3D Localization in 3D 3D virtual patient 3D model of images 3D virtual patient Slice séparation Example: 100 images, 512 * 512 pixels = 26.2 millions of voxels!! D frozen Voxel definition Surface rendering 3D model of contours Isocenter The contoured organs are becoming 3D objets The isocenter (barycenter) of the target volume (GTV) is defining the position of the objects system The isocenter is spotted by an orthogonal system of coordinates Patient marking The lasers system mimics the orthogonal system of coordinates The patient is tattoed at the lasers intersections with the skin 14

15 4D Localization 4D Localization 4D Localization 4D imaging 4D Localization Paradigm of target volumes definition Respiratory motion artefacts 2D MPR 3D rendering ICRU 50 & 62 GTV : Gross Tumor Volume CTV: + subclinical envolvement ITV: + Internal margin PTV: + Setup margin 4D imaging in RO can be used for assessing the ITV Helical CT: 1 turn / s Frozen virtual patient Inter-slices artifacts Internal organs movements Historical evolution of imaging in RT 4D CT Respiration affects the localization of many organs: Reference imaging MRI PET-CT 2006 CT Simulator Cone beam Courtesy of Philips Medical Systems Courtesy of Philips Medical Systems 1960 Portal imaging Verification imaging How to manage respiratory artefacts? Equipment for measuring respiratory phases Slow scanning technics Blurring PET 4D scanning Prospective (gating) Retrospective (sorting) Requires the measurement of the respiratory phases Pneumatic bellow RPM from Varian Spirometer Dyn R Spirometer ABC Elekta 15

16 Virtual simulation Virtual simulation Virtual simulation 4D Localization 4D Localization Multislices axial 4D-CT Organs delineation on 4D-CT CT images sorted by respiratory phases Low pitch spiral 4D-CT Organs delineation on 4D-CT CT images sorted by respiratory phases 90% 90% Example of lung tumor Colors = time spent in this position 10% Example of lung tumor 1 GTV per respiratory phase Internal Target Volume(ITV) 10% Courtesy of Philips Medical Systems Major steps in the RO workflow Localization Virtual simulation Dose planification See also delivery and verification session Guidance Irradiation Virtual simulation in RO Goal: Find the optimal balistic for irradiation which cover the target volume, Which spares the organs at risk. Material: Computer softwares(3d virtual simulation) Digitally Reconstructed Radiographs (DRR) Beam Eye View (BEV) Method: Beams conformation to target volume Choice of gantry angles Adaptation of the multileaves collimator (MLC) Technics of DRR s reconstruction Digitally Recontructed Radiographs(DRR) Reconstruction algorithm: Abrams et Goitein, 1983 Ray tracing : Siddon s method Interpolation : Trilinear or cubic Absorption : Curved integration Windowing : Remapping LUT table Technics of DRR s reconstruction Digitally Recontructed Radiographs(DRR) A exp i i dli i HNi i 1 water 1000 Hounsfield numbers HN i LUT i i voxel i D Pure mathematics Reconstruction algorithm: Abrams et Goitein, 1983 Ray tracing : Siddon s method Interpolation : Trilinear or cubic Absorption : Curved integration Windowing : Remapping LUT table 16

17 Image guidance Image guidance Image guidance Virtual simulation Beam Eye View method of virtual simulation Example of conformation on the prostate : Fusion of the projection of structures with DRR s Major steps in the RO workflow Localization Virtual simulation Guidance Anterio-Posterior beam DRR MLC GTV L-R Lateral beam Dose planification See treatmentirradiation planning sessions Major steps in the RO workflow Paradigm of target volumes definition Localization Virtual simulation See also delivery and verification session Guidance GTV : Gross Tumor Volume CTV: ITV: PTV: ICRU 50 & 62 + subclinical envolvement + Internal margin + Setup margin Dose planification Irradiation Image guidance in RO can be used for assessing the setup margin Goal: Image guidance in RO Check the treatment position of the patient Position of the target volume Position of the organs at risk Material: Imaging inside the treatment room With the iradiation beam (portal images) With an additional 3D imaging system (Echography, CBCT, ) Method: Registration with reference images DRR from virtual simulation(2d) CT slices from localization (3D) Various implementations of image guidance Electronic portal imaging : Set of 2D orthogonal portal images Golden markers MV CBCT Embarked kv imaging systems : Radiography Fluoroscopy CBCT Topometrical positioning systems Tomotherapy Stereoscopic kv imaging CT on rails Echography O-ring linac MR-Linac 17

18 CBCT guidance CBCT guidance CBCT guidance CBCT guidance CBCT guidance Historical evolution of imaging in RT 4D CT Cone Beam CT equipment Reference imaging MRI PET-CT 2006 X-ray tube kV CT 2000 Simulator Collimator Filter 1970 Cone beam am-si panel Carbon fiber table top 1960 Portal imaging Verification imaging Elekta Synergy system in operation at Rotation to 260 Irradiation from 260 to 100 Irradiation from 260 to 100 Irradiation from 260 to

19 CBCT guidance CBCT guidance CBCT guidance CBCT guidance CBCT guidance CBCT guidance Irradiation from 260 to 100 Irradiation from 260 to 100 CBCT 3D reconstruction Examples of CBCT images frames isocenter P ( y y ( y z y Flex, z Flex Flex, z z Flex ) ) :Correction isocenter FDK algorithm Skull H&N Lung Scatter corrections P y, z) P ( y, z) 0.33 P ( y, z) ( Frame Bladder Verterbras Prostate Filtration p( y, z) dz d P ( y, z) h( z z) d y z d :SAD 100 cm; h( z) : Median filter 5 Back-projection 2 1 d f r (, ) d p y z d r xˆ y f ( r):3d patient density dy drzˆ 0, z0 ( d rxˆ) ( d rxˆ ) Clinical images from Clinical uses of CBCT images 1/2 Setup margins verification: PTV Inter-fractions motion: translations rotations deformations Clinical uses of CBCT images 2/2 Morphological changes : Inter-fractions variations: Tumor response Weight loss ITV Intra-fraction motion measured by 4D IGRT: breathing Courtesy of AVL Intra-fraction variations gaz Swallowing 19

20 Major steps in the RO workflow Localization Virtual simulation See delivery and verification session Guidance Dose planification Irradiation Take home message 1/2 Imaging is present in 75% of the RO workflow Localization serves as reference for planning and irradiation delivery Delineation by radio-oncologist ICRU as normative framework Beware of the intrinsic limitations of modalities The evolution of localization involves: Fusion of modalities Functional imaging 4D imaging Always use your judgment expertise to accept delineation in fused set of data Imaging during treatment (guidance) involves the registration of the image of the day with a localization image used as reference 2D: matching of portal imaging with DRR s 3D: registration between CBCT and CT The evolution of guidance involves: Fusion of images Tracking of organs 4D guidance Take home message 2/2 Always use your judgment expertise to accept patient setup adaptation Special acknowledgements Myriam Ayadi (CLB, Lyon) Giovanna Pasquale (HUG, Genève) Francis Verdun (IRA, Lausanne) Frédéric Corminboeuf (Inselspital, Bern) Markus Notter, Pascal Baudet (, La Chaux-de-Fonds) Stéphane Montandon (PMS, Gland) Carlos Rodriges (PMS, Fitchburg) Sometimes imaging = miraging Thank you for your attention? 20

Ch. 4 Physical Principles of CT

Ch. 4 Physical Principles of CT Ch. 4 Physical Principles of CT CLRS 408: Intro to CT Department of Radiation Sciences Review: Why CT? Solution for radiography/tomography limitations Superimposition of structures Distinguishing between

More information

8/3/2016. Image Guidance Technologies. Introduction. Outline

8/3/2016. Image Guidance Technologies. Introduction. Outline 8/3/26 Session: Image Guidance Technologies and Management Strategies Image Guidance Technologies Jenghwa Chang, Ph.D.,2 Department of Radiation Medicine, Northwell Health 2 Hofstra Northwell School of

More information

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT CLINICAL COMMISSIONING AND ACCEPTANCE TESTING OF A 3D SURFACE MATCHING SYSTEM Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago Learning Objective Describe acceptance

More information

Medical Images Analysis and Processing

Medical Images Analysis and Processing Medical Images Analysis and Processing - 25642 Emad Course Introduction Course Information: Type: Graduated Credits: 3 Prerequisites: Digital Image Processing Course Introduction Reference(s): Insight

More information

Tomographic Reconstruction

Tomographic Reconstruction Tomographic Reconstruction 3D Image Processing Torsten Möller Reading Gonzales + Woods, Chapter 5.11 2 Overview Physics History Reconstruction basic idea Radon transform Fourier-Slice theorem (Parallel-beam)

More information

Brilliance CT Big Bore.

Brilliance CT Big Bore. 1 2 2 There are two methods of RCCT acquisition in widespread clinical use: cine axial and helical. In RCCT with cine axial acquisition, repeat CT images are taken each couch position while recording respiration.

More information

BME I5000: Biomedical Imaging

BME I5000: Biomedical Imaging 1 Lucas Parra, CCNY BME I5000: Biomedical Imaging Lecture 4 Computed Tomography Lucas C. Parra, parra@ccny.cuny.edu some slides inspired by lecture notes of Andreas H. Hilscher at Columbia University.

More information

Image Acquisition Systems

Image Acquisition Systems Image Acquisition Systems Goals and Terminology Conventional Radiography Axial Tomography Computer Axial Tomography (CAT) Magnetic Resonance Imaging (MRI) PET, SPECT Ultrasound Microscopy Imaging ITCS

More information

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator Andrew J Reilly Imaging Physicist Oncology Physics Edinburgh Cancer Centre Western General Hospital EDINBURGH EH4

More information

Image Guidance and Beam Level Imaging in Digital Linacs

Image Guidance and Beam Level Imaging in Digital Linacs Image Guidance and Beam Level Imaging in Digital Linacs Ruijiang Li, Ph.D. Department of Radiation Oncology Stanford University School of Medicine 2014 AAPM Therapy Educational Course Disclosure Research

More information

Image Quality Assessment and Quality Assurance of Advanced Imaging Systems for IGRT. AAPM Penn-Ohio Chapter Sep 25, 2015 Soyoung Lee, PhD

Image Quality Assessment and Quality Assurance of Advanced Imaging Systems for IGRT. AAPM Penn-Ohio Chapter Sep 25, 2015 Soyoung Lee, PhD Image Quality Assessment and Quality Assurance of Advanced Imaging Systems for IGRT AAPM Penn-Ohio Chapter Sep 25, 2015 Soyoung Lee, PhD 1 Outline q Introduction q Imaging performances in 4D-CBCT Image

More information

Patient Set-ups and Tumor Localizations

Patient Set-ups and Tumor Localizations Patient Set-ups and Tumor Localizations Amy S. Harrison Patient Positioning Prior to starting any localization or simulation procedure patients need to be positioned and immobilized Patients disease location

More information

Computational Medical Imaging Analysis

Computational Medical Imaging Analysis Computational Medical Imaging Analysis Chapter 1: Introduction to Imaging Science Jun Zhang Laboratory for Computational Medical Imaging & Data Analysis Department of Computer Science University of Kentucky

More information

IMRT site-specific procedure: Prostate (CHHiP)

IMRT site-specific procedure: Prostate (CHHiP) IMRT site-specific procedure: Prostate (CHHiP) Scope: To provide site specific instructions for the planning of CHHIP IMRT patients Responsibilities: Radiotherapy Physicists, HPC Registered Therapy Radiographers

More information

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH 3/27/212 Advantages of SPECT SPECT / CT Basic Principles Dr John C. Dickson, Principal Physicist UCLH Institute of Nuclear Medicine, University College London Hospitals and University College London john.dickson@uclh.nhs.uk

More information

State-of-the-Art IGRT

State-of-the-Art IGRT in partnership with State-of-the-Art IGRT Exploring the Potential of High-Precision Dose Delivery and Real-Time Knowledge of the Target Volume Location Antje-Christin Knopf IOP Medical Physics Group Scientific

More information

Using a research real-time control interface to go beyond dynamic MLC tracking

Using a research real-time control interface to go beyond dynamic MLC tracking in partnership with Using a research real-time control interface to go beyond dynamic MLC tracking Dr. Simeon Nill Joint Department of Physics at The Institute of Cancer Research and the Royal Marsden

More information

Corso di laurea in Fisica A.A Fisica Medica 4 TC

Corso di laurea in Fisica A.A Fisica Medica 4 TC Corso di laurea in Fisica A.A. 2007-2008 Fisica Medica 4 TC Computed Tomography Principles 1. Projection measurement 2. Scanner systems 3. Scanning modes Basic Tomographic Principle The internal structure

More information

ADVANCING CANCER TREATMENT

ADVANCING CANCER TREATMENT The RayPlan treatment planning system makes proven, innovative RayStation technology accessible to clinics that need a cost-effective and streamlined solution. Fast, efficient and straightforward to use,

More information

Technical aspects of SPECT and SPECT-CT. John Buscombe

Technical aspects of SPECT and SPECT-CT. John Buscombe Technical aspects of SPECT and SPECT-CT John Buscombe What does the clinician need to know? For SPECT What factors affect SPECT How those factors should be sought Looking for artefacts For SPECT-CT Issues

More information

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING Reveal pathology Reveal the anatomic truth Steven R. Singer, DDS srs2@columbia.edu IDEAL DIAGNOSTIC IMAGING STUDY Provides desired diagnostic

More information

iplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration

iplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration iplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration The iplan Contouring Workstation offers unique and innovative capabilities for faster contouring and consistent segmentation

More information

Digital Image Processing

Digital Image Processing Digital Image Processing SPECIAL TOPICS CT IMAGES Hamid R. Rabiee Fall 2015 What is an image? 2 Are images only about visual concepts? We ve already seen that there are other kinds of image. In this lecture

More information

Tumor motion during liver SBRT

Tumor motion during liver SBRT Tumor motion during liver SBRT - projects at Aarhus University Hospital - Per Poulsen, Esben Worm, Walther Fledelius, Morten Høyer Aarhus University Hospital, Denmark SBRT: Stereotactic Body Radiation

More information

ADVANCING CANCER TREATMENT

ADVANCING CANCER TREATMENT 3 ADVANCING CANCER TREATMENT SUPPORTING CLINICS WORLDWIDE RaySearch is advancing cancer treatment through pioneering software. We believe software has un limited potential, and that it is now the driving

More information

Fundamentals of CT imaging

Fundamentals of CT imaging SECTION 1 Fundamentals of CT imaging I History In the early 1970s Sir Godfrey Hounsfield s research produced the first clinically useful CT scans. Original scanners took approximately 6 minutes to perform

More information

1. Learn to incorporate QA for surface imaging

1. Learn to incorporate QA for surface imaging Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago ***No disclosures*** 1. Learn to incorporate QA for surface imaging into current QA procedures for IGRT. 2. Understand

More information

Financial disclosure. Onboard imaging modality for IGRT

Financial disclosure. Onboard imaging modality for IGRT Tetrahedron Beam Computed Tomography Based On Multi-Pixel X- Ray Source and Its Application in Image Guided Radiotherapy Tiezhi Zhang, Ph.D. Advanced X-ray imaging Lab Financial disclosure Patent royalty

More information

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon WHITE PAPER Introduction Introducing an image guidance system based on Cone Beam CT (CBCT) and a mask immobilization

More information

Good Morning! Thank you for joining us

Good Morning! Thank you for joining us Good Morning! Thank you for joining us Deformable Registration, Contour Propagation and Dose Mapping: 101 and 201 Marc Kessler, PhD, FAAPM The University of Michigan Conflict of Interest I receive direct

More information

Diagnostic imaging techniques. Krasznai Zoltán. University of Debrecen Medical and Health Science Centre Department of Biophysics and Cell Biology

Diagnostic imaging techniques. Krasznai Zoltán. University of Debrecen Medical and Health Science Centre Department of Biophysics and Cell Biology Diagnostic imaging techniques Krasznai Zoltán University of Debrecen Medical and Health Science Centre Department of Biophysics and Cell Biology 1. Computer tomography (CT) 2. Gamma camera 3. Single Photon

More information

Basic Radiation Oncology Physics

Basic Radiation Oncology Physics Basic Radiation Oncology Physics T. Ganesh, Ph.D., DABR Chief Medical Physicist Fortis Memorial Research Institute Gurgaon Acknowledgment: I gratefully acknowledge the IAEA resources of teaching slides

More information

Monaco VMAT. The Next Generation in IMRT/VMAT Planning. Paulo Mathias Customer Support TPS Application

Monaco VMAT. The Next Generation in IMRT/VMAT Planning. Paulo Mathias Customer Support TPS Application Monaco VMAT The Next Generation in IMRT/VMAT Planning Paulo Mathias Customer Support TPS Application 11.05.2011 Background What is Monaco? Advanced IMRT/VMAT treatment planning system from Elekta Software

More information

Introduction to Biomedical Imaging

Introduction to Biomedical Imaging Alejandro Frangi, PhD Computational Imaging Lab Department of Information & Communication Technology Pompeu Fabra University www.cilab.upf.edu X-ray Projection Imaging Computed Tomography Digital X-ray

More information

Virtual Phantoms for IGRT QA

Virtual Phantoms for IGRT QA TM Virtual Phantoms for IGRT QA Why ImSimQA? ImSimQA was developed to overcome the limitations of physical phantoms for testing modern medical imaging and radiation therapy software systems, when there

More information

GPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC

GPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC GPU applications in Cancer Radiation Therapy at UCSD Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC Conventional Radiotherapy SIMULATION: Construciton, Dij Days PLANNING:

More information

UNIVERSITY OF SOUTHAMPTON

UNIVERSITY OF SOUTHAMPTON UNIVERSITY OF SOUTHAMPTON PHYS2007W1 SEMESTER 2 EXAMINATION 2014-2015 MEDICAL PHYSICS Duration: 120 MINS (2 hours) This paper contains 10 questions. Answer all questions in Section A and only two questions

More information

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada Overview Introduction Overview Introduction Tecniques of imaging in Overview Introduction Tecniques of imaging

More information

ROBUST OPTIMIZATION THE END OF PTV AND THE BEGINNING OF SMART DOSE CLOUD. Moe Siddiqui, April 08, 2017

ROBUST OPTIMIZATION THE END OF PTV AND THE BEGINNING OF SMART DOSE CLOUD. Moe Siddiqui, April 08, 2017 ROBUST OPTIMIZATION THE END OF PTV AND THE BEGINNING OF SMART DOSE CLOUD Moe Siddiqui, April 08, 2017 Agenda Background IRCU 50 - Disclaimer - Uncertainties Robust optimization Use Cases Lung Robust 4D

More information

Is deformable image registration a solved problem?

Is deformable image registration a solved problem? Is deformable image registration a solved problem? Marcel van Herk On behalf of the imaging group of the RT department of NKI/AVL Amsterdam, the Netherlands DIR 1 Image registration Find translation.deformation

More information

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram TomoTherapy Related Projects An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram Development of A Novel Image Guidance Alternative for Patient Localization

More information

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS Tomotherapy Physics Machine Twinning and Quality Assurance Emilie Soisson, MS Tomotherapy at UW- Madison Treating for nearly 5 years Up to ~45 patients a day on 2 tomo units Units twinned to facilitate

More information

Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies

Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies g Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies Presented by Adam Kesner, Ph.D., DABR Assistant Professor, Division of Radiological Sciences,

More information

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588 ICARO Vienna April 27-29 2009 Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588 M. Saiful Huq, Ph.D., Professor and Director, Dept. of Radiation

More information

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA Computed Tomography Principles, Design, Artifacts, and Recent Advances THIRD EDITION Jiang Hsieh SPIE PRESS Bellingham, Washington USA Table of Contents Preface Nomenclature and Abbreviations xi xv 1 Introduction

More information

Computational Medical Imaging Analysis

Computational Medical Imaging Analysis Computational Medical Imaging Analysis Chapter 2: Image Acquisition Systems Jun Zhang Laboratory for Computational Medical Imaging & Data Analysis Department of Computer Science University of Kentucky

More information

RADIOMICS: potential role in the clinics and challenges

RADIOMICS: potential role in the clinics and challenges 27 giugno 2018 Dipartimento di Fisica Università degli Studi di Milano RADIOMICS: potential role in the clinics and challenges Dr. Francesca Botta Medical Physicist Istituto Europeo di Oncologia (Milano)

More information

Hugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France. Sunday 17 July 2016

Hugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France. Sunday 17 July 2016 Hugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France Sunday 17 July 2016 AGENDA 1. Introduction 2. Material 3. Optimization process 4. Results 5. Comments 6. Conclusion

More information

Initial Clinical Experience with 3D Surface Image Guidance

Initial Clinical Experience with 3D Surface Image Guidance Initial Clinical Experience with 3D Surface Image Guidance Amanda Havnen-Smith, Ph.D. Minneapolis Radiation Oncology Ridges Radiation Therapy Center Burnsville, MN April 20 th, 2012 Non-funded research

More information

Medical Image Analysis

Medical Image Analysis Computer assisted Image Analysis VT04 29 april 2004 Medical Image Analysis Lecture 10 (part 1) Xavier Tizon Medical Image Processing Medical imaging modalities XRay,, CT Ultrasound MRI PET, SPECT Generic

More information

Clinical Prospects and Technological Challenges for Multimodality Imaging Applications in Radiotherapy Treatment Planning

Clinical Prospects and Technological Challenges for Multimodality Imaging Applications in Radiotherapy Treatment Planning Clinical Prospects and Technological Challenges for Multimodality Imaging Applications in Radiotherapy Treatment Planning Issam El Naqa, PhD Assistant Professor Department of Radiation Oncology Washington

More information

Digital Tomosynthesis for Target Localization

Digital Tomosynthesis for Target Localization Digital Tomosynthesis for Target Localization Fang-Fang Yin, Devon Godfrey, Lei Ren Jacqueline Maurer, Jackie Q-L Wu Duke University Medical Center Acknowledgements Duke Radiation Oncology faculty and

More information

PET/CT multimodality imaging for radiotherapy planning in lung cancer The medical physicist point of view Isabelle Gardin Rouen CHB and Quant.I.

PET/CT multimodality imaging for radiotherapy planning in lung cancer The medical physicist point of view Isabelle Gardin Rouen CHB and Quant.I. PET/CT multimodality imaging for radiotherapy planning in lung cancer The medical physicist point of view Isabelle Gardin Rouen CHB and Quant.I.F (EA4108 FR CNRS 3638) Outline Specific acquisition conditions

More information

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead. 1 CT Basics Principles of Spiral CT Dose 2 Who invented CT? 1963 - Alan Cormack developed a mathematical method of reconstructing images from x-ray projections Sir Godfrey Hounsfield worked for the Central

More information

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago Optimization of CT Simulation Imaging Ingrid Reiser Dept. of Radiology The University of Chicago Optimization of CT imaging Goal: Achieve image quality that allows to perform the task at hand (diagnostic

More information

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0 Revised 10/10 COURSE SYLLABUS TM 220 COMPUTED TOMOGRAPHY PHYSICS CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0 CATALOG COURSE DESCRIPTION: This course is one of a three course set in whole body Computed

More information

MR-guided radiotherapy: Vision, status and research at the UMC Utrecht. Dipl. Ing. Dr. Markus Glitzner

MR-guided radiotherapy: Vision, status and research at the UMC Utrecht. Dipl. Ing. Dr. Markus Glitzner MR-guided radiotherapy: Vision, status and research at the UMC Utrecht Dipl. Ing. Dr. Markus Glitzner About myself Training Medizintechnik TU Graz PhD UMC Utrecht Clinical work Software implementation

More information

SRI GURU RAMDAS INSTITUTE OF MEDICAL SCIENCES & RESEARCH MEHTA ROAD, VALLAH, SRI AMRITSAR

SRI GURU RAMDAS INSTITUTE OF MEDICAL SCIENCES & RESEARCH MEHTA ROAD, VALLAH, SRI AMRITSAR SRI GURU RAMDAS INSTITUTE OF MEDICAL SCIENCES & RESEARCH MEHTA ROAD, VALLAH, SRI AMRITSAR TECHNICAL SPECIFICATIONS FOR PURCHASE OF CT SIMULATOR FOR DEPARTMENT OF RADIOTHERAPY 1. MANDATORY REQUIREMENTS

More information

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT Volumetric Modulated Arc Therapy - Clinical Implementation Daliang Cao, PhD, DABR Swedish Cancer Institute, Seattle, WA Acknowledgement David M. Shepard, Ph.D. Muhammad K. N. Afghan, Ph.D. Fan Chen, Ph.D.

More information

Validation of PET/CT dataset for radiation treatment planning

Validation of PET/CT dataset for radiation treatment planning Louisiana State University LSU Digital Commons LSU Master's Theses Graduate School 2004 Validation of PET/CT dataset for radiation treatment planning Rajesh Manoharan Louisiana State University and Agricultural

More information

The IORT Treatment Planning System. radiance. GMV, 2012 Property of GMV All rights reserved

The IORT Treatment Planning System. radiance. GMV, 2012 Property of GMV All rights reserved The IORT Treatment Planning System radiance Property of GMV All rights reserved WHY RADIANCE? JUSTIFICATION Property of GMV All rights reserved ADVANTAGES OF IORT PRECISION: RT guided by direct vision.

More information

Medical Image Processing: Image Reconstruction and 3D Renderings

Medical Image Processing: Image Reconstruction and 3D Renderings Medical Image Processing: Image Reconstruction and 3D Renderings 김보형 서울대학교컴퓨터공학부 Computer Graphics and Image Processing Lab. 2011. 3. 23 1 Computer Graphics & Image Processing Computer Graphics : Create,

More information

Constructing System Matrices for SPECT Simulations and Reconstructions

Constructing System Matrices for SPECT Simulations and Reconstructions Constructing System Matrices for SPECT Simulations and Reconstructions Nirantha Balagopal April 28th, 2017 M.S. Report The University of Arizona College of Optical Sciences 1 Acknowledgement I would like

More information

MEDICAL IMAGE ANALYSIS

MEDICAL IMAGE ANALYSIS SECOND EDITION MEDICAL IMAGE ANALYSIS ATAM P. DHAWAN g, A B IEEE Engineering in Medicine and Biology Society, Sponsor IEEE Press Series in Biomedical Engineering Metin Akay, Series Editor +IEEE IEEE PRESS

More information

Basic principles of MR image analysis. Basic principles of MR image analysis. Basic principles of MR image analysis

Basic principles of MR image analysis. Basic principles of MR image analysis. Basic principles of MR image analysis Basic principles of MR image analysis Basic principles of MR image analysis Julien Milles Leiden University Medical Center Terminology of fmri Brain extraction Registration Linear registration Non-linear

More information

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY Prof. Yasser Mostafa Kadah www.k-space.org Recommended Textbook X-Ray Computed Tomography in Biomedical Engineering, by Robert Cierniak, Springer, 211 Computed Tomography

More information

Philips SPECT/CT Systems

Philips SPECT/CT Systems Philips SPECT/CT Systems Ling Shao, PhD Director, Imaging Physics & System Analysis Nuclear Medicine, Philips Healthcare June 14, 2008 *Presented SNM08 Categorical Seminar - Quantitative SPECT and PET

More information

LAB DEMONSTRATION COMPUTED TOMOGRAPHY USING DESKCAT Lab Manual: 0

LAB DEMONSTRATION COMPUTED TOMOGRAPHY USING DESKCAT Lab Manual: 0 LAB DEMONSTRATION COMPUTED TOMOGRAPHY USING DESKCAT Lab Manual: 0 Introduction This lab demonstration explores the physics and technology of Computed Tomography (CT) and guides the student and instructor

More information

CP Generalize Concepts in Abstract Multi-dimensional Image Model Component Semantics. David Clunie.

CP Generalize Concepts in Abstract Multi-dimensional Image Model Component Semantics. David Clunie. CP-1390 - Generalize Concepts in Abstract Multi-dimensional Image Model Semantics Page 1 STATUS Date of Last Update Person Assigned Submitter Name Submission Date Assigned 2014/06/09 David Clunie mailto:dclunie@dclunie.com

More information

Volume Interaction Techniques in the Virtual Simulation of Radiotherapy Treatment Planning

Volume Interaction Techniques in the Virtual Simulation of Radiotherapy Treatment Planning Volume Interaction Techniques in the Virtual Simulation of Radiotherapy Treatment Planning Wenli Cai, Grigorios Karangelis, and Georgios Sakas Fraunhofer Institute for Computer Graphics Rundeturmstrasse

More information

RADIOLOGY AND DIAGNOSTIC IMAGING

RADIOLOGY AND DIAGNOSTIC IMAGING Day 2 part 2 RADIOLOGY AND DIAGNOSTIC IMAGING Dr hab. Zbigniew Serafin, MD, PhD serafin@cm.umk.pl 2 3 4 5 CT technique CT technique 6 CT system Kanal K: RSNA/AAPM web module: CT Systems & CT Image Quality

More information

UvA-DARE (Digital Academic Repository) Motion compensation for 4D PET/CT Kruis, M.F. Link to publication

UvA-DARE (Digital Academic Repository) Motion compensation for 4D PET/CT Kruis, M.F. Link to publication UvA-DARE (Digital Academic Repository) Motion compensation for 4D PET/CT Kruis, M.F. Link to publication Citation for published version (APA): Kruis, M. F. (2014). Motion compensation for 4D PET/CT General

More information

Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT

Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT Marcus Brehm 1,2, Thorsten Heußer 1, Pascal Paysan 3, Markus Oehlhafen 3, and Marc Kachelrieß 1,2 1 German Cancer Research Center

More information

Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No.

Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132 Kristy K. Brock a) Department of Imaging Physics, The University

More information

Thoracic target volume delineation using various maximum-intensity projection computed tomography image sets for stereotactic body radiation therapy

Thoracic target volume delineation using various maximum-intensity projection computed tomography image sets for stereotactic body radiation therapy Texas Medical Center Library DigitalCommons@TMC UT GSBS Dissertations and Theses (Open Access) Graduate School of Biomedical Sciences 8-2010 Thoracic target volume delineation using various maximum-intensity

More information

Chapter 9 Field Shaping: Scanning Beam

Chapter 9 Field Shaping: Scanning Beam Chapter 9 Field Shaping: Scanning Beam X. Ronald Zhu, Ph.D. Department of Radiation Physics M. D. Anderson Cancer Center Houston, TX June 14-18, 2015 AAPM - Summer School 2015, Colorado Spring Acknowledgement

More information

Joint CI-JAI advanced accelerator lecture series Imaging and detectors for medical physics Lecture 1: Medical imaging

Joint CI-JAI advanced accelerator lecture series Imaging and detectors for medical physics Lecture 1: Medical imaging Joint CI-JAI advanced accelerator lecture series Imaging and detectors for medical physics Lecture 1: Medical imaging Dr Barbara Camanzi barbara.camanzi@stfc.ac.uk Course layout Day AM 09.30 11.00 PM 15.30

More information

Integrated proton-photon treatment planning

Integrated proton-photon treatment planning Pinnacle 3 Proton Planning Integrated proton-photon treatment planning Philips Pinnacle 3 Proton Planning specifications Pinnacle 3 Proton Planning is designed to simplify treatment planning for proton

More information

URGENT IMPORTANT FIELD SAFETY NOTIFICATION

URGENT IMPORTANT FIELD SAFETY NOTIFICATION Subject: Incorrect Movement of the Treatment Table Product: MOSAIQ Scope: Sites affected will be those: 1. Running MOSAIQ and, 2. Treating on linear accelerators with the RATM license Notification Released:

More information

Image Guided Multibeam Radiotherapy

Image Guided Multibeam Radiotherapy José Luis Freijo a* Image Guided Multibeam Radiotherapy a Comisión Nacional de Energía Atómica, Av. del Libertador 8250, 1429, Buenos Aires, Argentina. Abstract. This paper provides an outlook of the status

More information

Introduction to Positron Emission Tomography

Introduction to Positron Emission Tomography Planar and SPECT Cameras Summary Introduction to Positron Emission Tomography, Ph.D. Nuclear Medicine Basic Science Lectures srbowen@uw.edu System components: Collimator Detector Electronics Collimator

More information

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT Anand P Santhanam Assistant Professor, Department of Radiation Oncology OUTLINE Adaptive radiotherapy for head and

More information

Volumetric Cine Imaging for On-board Target Localization in Radiation Therapy. Wendy Beth Harris. Graduate Program in Medical Physics Duke University

Volumetric Cine Imaging for On-board Target Localization in Radiation Therapy. Wendy Beth Harris. Graduate Program in Medical Physics Duke University Volumetric Cine Imaging for On-board Target Localization in Radiation Therapy by Wendy Beth Harris Graduate Program in Medical Physics Duke University Date: Approved: Lei Ren, Supervisor Fang-Fang Yin,

More information

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA Spiral CT Protocol Optimization & Quality Assurance Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA Spiral CT Protocol Optimization & Quality Assurance Protocol optimization

More information

Medical Imaging BMEN Spring 2016

Medical Imaging BMEN Spring 2016 Name Medical Imaging BMEN 420-501 Spring 2016 Homework #4 and Nuclear Medicine Notes All questions are from the introductory Powerpoint (based on Chapter 7) and text Medical Imaging Signals and Systems,

More information

VALIDATION OF DIR. Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology

VALIDATION OF DIR. Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology VALIDATION OF DIR Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology Overview Basics: Registration Framework, Theory Discuss Validation techniques Using Synthetic CT data & Phantoms What metrics to

More information

Image Co-Registration II: TG132 Quality Assurance for Image Registration. Image Co-Registration II: TG132 Quality Assurance for Image Registration

Image Co-Registration II: TG132 Quality Assurance for Image Registration. Image Co-Registration II: TG132 Quality Assurance for Image Registration Image Co-Registration II: TG132 Quality Assurance for Image Registration Preliminary Recommendations from TG 132* Kristy Brock, Sasa Mutic, Todd McNutt, Hua Li, and Marc Kessler *Recommendations are NOT

More information

TG 132: Use of Image Registration and Fusion in RT

TG 132: Use of Image Registration and Fusion in RT TG 132: Use of Image Registration and Fusion in RT Kristy K Brock, PhD, DABR, FAAPM Associate Professor Department of Radiation Oncology, University of Michigan Chair, AAPM TG 132: Image Registration and

More information

Evaluation report. X-ray tomographic image guided radiotherapy systems CEP10071

Evaluation report. X-ray tomographic image guided radiotherapy systems CEP10071 Evaluation report X-ray tomographic image guided radiotherapy systems CEP10071 March 2010 Contents 2 Summary... 3 Introduction... 6 Product description... 9 Methods... 14 Technical performance... 23 Purchasing...

More information

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D. Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D. Applied Science Laboratory, GE Healthcare Technologies 1 Image Generation Reconstruction of images from projections. textbook reconstruction advanced

More information

Optical Guidance. Sanford L. Meeks. July 22, 2010

Optical Guidance. Sanford L. Meeks. July 22, 2010 Optical Guidance Sanford L. Meeks July 22, 2010 Optical Tracking Optical tracking is a means of determining in real-time the position of a patient relative to the treatment unit. Markerbased systems track

More information

The MSKCC Approach to IMRT. Outline

The MSKCC Approach to IMRT. Outline The MSKCC Approach to IMRT Spiridon V. Spirou, PhD Department of Medical Physics Memorial Sloan-Kettering Cancer Center New York, NY Outline Optimization Field splitting Delivery Independent verification

More information

radiotherapy Andrew Godley, Ergun Ahunbay, Cheng Peng, and X. Allen Li NCAAPM Spring Meeting 2010 Madison, WI

radiotherapy Andrew Godley, Ergun Ahunbay, Cheng Peng, and X. Allen Li NCAAPM Spring Meeting 2010 Madison, WI GPU-Accelerated autosegmentation for adaptive radiotherapy Andrew Godley, Ergun Ahunbay, Cheng Peng, and X. Allen Li agodley@mcw.edu NCAAPM Spring Meeting 2010 Madison, WI Overview Motivation Adaptive

More information

Introduction. Quality Assurance for Image- Guided Radiation Therapy. Justification for IGRT. Image-Guided Radiation Therapy

Introduction. Quality Assurance for Image- Guided Radiation Therapy. Justification for IGRT. Image-Guided Radiation Therapy Introduction Quality Assurance for Image- Guided Radiation Therapy Jean-Pierre Bissonnette, Ph.D., MCCPM Princess Margaret Hospital, Toronto, Canada IGRT What is it? Rationale Equipment Quality Assurance

More information

IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques

IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques Report of the Coordinated Research Project (CRP) on Development of Procedures

More information

INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory

INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1 Modifications for P551 Fall 2013 Medical Physics Laboratory Introduction Following the introductory lab 0, this lab exercise the student through

More information

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE QA SOFTWARE FAST, PRECISE Software for accurate and independent verification of monitor units, dose, and overall validity of standard, IMRT, VMAT, SRS and brachytherapy plans no film, no phantoms, no linac

More information

PURE. ViSION Edition PET/CT. Patient Comfort Put First.

PURE. ViSION Edition PET/CT. Patient Comfort Put First. PURE ViSION Edition PET/CT Patient Comfort Put First. 2 System features that put patient comfort and safety first. Oncology patients deserve the highest levels of safety and comfort during scans. Our Celesteion

More information

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid by Yingxuan Chen Graduate Program in Medical Physics Duke University Date: Approved: Lei Ren, Supervisor Fang Fang Yin, Chair

More information

A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study

A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study Indrin J. Chetty, a) Mihaela Rosu, Neelam Tyagi, Lon H. Marsh, Daniel

More information