Advanced Reconstruction Techniques Applied to an On-Site CT System

Size: px
Start display at page:

Download "Advanced Reconstruction Techniques Applied to an On-Site CT System"

Transcription

1 2nd International Symposium on NDT in Aerospace We.1.A.4 Advanced Reconstruction Techniques Applied to an On-Site CT System Jonathan HESS, Markus EBERHORN, Markus HOFMANN, Maik LUXA Fraunhofer Development Center for X-Ray Technology EZRT, Fuerth, Germany Abstract. The 3D inspection of large or already mounted modules is not possible by conventional means up to now. This poses a challenge to non-destructive testing. It is shown that by using a system consisting of two robots and by using suitable calibration procedures a mobile CT system in short Robo-CT can be realized. For these new calibration procedures a method for image based pose estimation was devolved which allows a precise determination of the system alignment. By using new calibration methods and advanced reconstruction techniques, 3D volumes can be generated. 1. Introduction The 3D inspection of large or already mounted modules is not possible by conventional means up to now. This poses a challenge to non-destructive testing. Today s 3D x-ray systems depend on a circular movement of the specimen, while x- ray source and detector are fixed. By mounting the source and/or the detector on an independent manipulation system, the increased degrees of freedom can be used to gather a series of 2D projections while moving around the specimen. The Fraunhofer IIS developed new methods for image based pose estimation, allowing a precise determination of detector and source positions. In the majority of cases the traverse path is limited by the dimensions of the specimen. Therefore the trajectories are adapted to fit in the available work envelope. A demonstration system located at the Development Center for X-Ray Technologies (EZRT) in Fuerth, consisting of two robots holding an x-ray source and detector, shows the capabilities of these methods. 2. System Set-up The Fraunhofer Development Center X-Ray Technology (EZRT) has developed a prototype system (Figure 1) consisting of two robots, a mini focus x-ray tube and a digital flat panel detector. Using this prototype a new calibration procedure and advanced reconstruction techniques for on-site CT systems are evaluated. Licence: 1

2 Figure 1: System set-up mobile Computed Tomography 2.1 Robots Robot arms of the Stäubli RX90 series have a maximum payload of 7 kg and a maximum range of 900 mm when using the standard six axis set-up. Taking into account these conditions a suitable x-ray source and detector were chosen which do not surpass the maximum load and have a compact size. Thus, a minimal limitation of operating range is assured. It should be mentioned that positioning precision and repeatability decrease with increasing payload. Both arms are mounted on mobile sockets that allow manual positioning. Four pedestals ensure a stable base of the robots after positioning. The tool mount is adequate for the simultaneous mounting of the UltraCal laser system[1] and the x- ray components. 2.2 X-ray Components The x-ray detector Hamamatsu C9311DK comes with an active pixel size (Pitch) of 100 x 100 µm and a CsI Scintillator. The x-ray source MXR-160HP/11 manufactured by Comet AG comes with a focal spot size of 0.4 mm and 1.0 mm according to EN The voltage range is about kv with a maximum dose output of 800 W on the small focal spot and 1800 W respectively on the big spot. A fist setup was realized with an detector which was available at the Fraunhofer IIS. The payload of the robots was limited, so an optimal matching of focal spot size and detector pitch was not possible. 2

3 2.3 Laser-calibration system The UltraCal laser system is consisting of a class 2 laser with integrated laser sensor and a retro reflector that reflects incident laser light parallel. The retro reflection is done by a triple mirror consisting of three perpendicular mirrors. The included sensor offers a laser shift in two dimensions with a precision of ±25 µm. 2.4 Manipulator control The control system of the Robo-CT was transparently mapped onto the interfaces of a conventional CT system. Thus, it is possible to use existing software libraries and acquisition methods. The manipulation of the object carrier common in industrial CT systems is mimicked by the simultaneous movement of both robots. Together with the six degrees of freedom for the manipulation of the x-ray source and the detector no limitations arise for the system's trajectories. 3. Initial system calibration The two robots are fully independent and therefore a recalibration is necessary, after they have been positioned at the testing site. The UltraCal laser system is used for the initial system calibration which determines the relative position of the robots towards each other. The values calculated by the UltraCal Laser system have a deviation of around 300 µm, but for the reconstruction an even higher precision is necessary. Additionally the relative position of the robots to the object has to be determined. These values can be calculated by analysing the x-ray-projections of a calibration-object. This technique is called pose estimation. 4. Pose estimation As already mentioned, the relation of x-ray tube and detector to each other, as well as the relation of the specimen to the robots is unknown. A calibration object is placed next to the specimen and visible on each projection. The geometry of the calibration object was previously determined by a conventional coordinate measuring machine. A special calibration object was designed for the use with the Robo- CT. It is basically a small rod with attached spheres in helical pattern which is shown in figure 2. The distribution of the spheres in space is an advantage in means of misalignments. The helical pattern is robust against misalignments and it allows a positioning of the object, where no overlap of the spheres during a measurement occurs. If the measurement geometry and the calibration object are well known, it is possible to calculate the translation and rotation of the x-ray- source and the detector. For this calculation the POSIT algorithm is used [2]. Designed for use with cameras and LEDs, the algorithm can be applied to the Robo-CT. 3

4 Figure 2. A three dimensional model of the calibration rod With this information the pose of the calibration object in every single projection can be calculated. Using the calibration object of the first projection as a reference and relating the poses of all other projections to this first one, a set of position data for the ART (Algebraic Reconstruction Technique) reconstruction [3] can be generated. Experiments have shown that the quality of the reconstruction can be improved significantly by using object calibration. The figures 3 and 4 show impact damages on a fibre reinforced composite plate. Evidently, artefacts and noise are reduced. The plate was inspected using a 90 degrees limited angle CT Figure 3. Uncorrected reconstruction 4

5 Figure 4. Corrected reconstruction 6. Summary and Outlook It is shown, that by combining high accuracy position determination and advanced reconstruction techniques, the generated 3D volumes can be improved. The used algorithms can cope with imprecise measuring setups and make it possible to use arbitrary geometries for acquiring projections. Acknowledgements This Project is co-financed by the European Union and the Free State of Bavaria. References [1] UltraCal Robot Calibration System, Robo-Technology GmbH, [2] Daniel F. DeMenthon und Larry S. Davis: Model-Based Object Pose in 25 Lines of Code. Computer Vision Laboratory, University of Maryland, Maryland, 1995 [3] Avinash C. Kak und Malcom Slanley: Principles of Computerized Tomographic Imaging. IEEE Press, New York, 1. Auflage,

An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography

An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography 4th International Symposium on NDT in Aerospace 2012 - Tu.3.A.3 An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography Jonathan HESS *, Patrick KUEHNLEIN *, Steven OECKL

More information

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications 4th International Symposium on NDT in Aerospace 2012 - Tu.3.A.1 Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications Malte KURFISS 1, Gerd STRECKENBACH 2 1 YXLON International

More information

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling nd International Symposium on NDT in Aerospace - We..A. Comparison of Probing Error in Dimensional Measurement by Means of D Computed Tomography with Circular and Helical Sampling Jochen HILLER, Stefan

More information

Comparison of Reconstruction Methods for Computed Tomography with Industrial Robots using Automatic Object Position Recognition

Comparison of Reconstruction Methods for Computed Tomography with Industrial Robots using Automatic Object Position Recognition 19 th World Conference on Non-Destructive Testing 2016 Comparison of Reconstruction Methods for Computed Tomography with Industrial Robots using Automatic Object Position Recognition Philipp KLEIN 1, Frank

More information

Translational Computed Tomography: A New Data Acquisition Scheme

Translational Computed Tomography: A New Data Acquisition Scheme 2nd International Symposium on NDT in Aerospace 2010 - We.1.A.3 Translational Computed Tomography: A New Data Acquisition Scheme Theobald FUCHS 1, Tobias SCHÖN 2, Randolf HANKE 3 1 Fraunhofer Development

More information

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system ECNDT 2014 Prague October 6-10, 2014 Dr. Eberhard Neuser Dr. Alexander Suppes Imagination

More information

Industrial Computed Tomography Innovations

Industrial Computed Tomography Innovations GE Inspection Technologies Industrial Computed Tomography Innovations Premium performance for premium quality and speed. gemeasurement.com/ct Premium CT technologies. Faster than ever before. Every industrial

More information

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY David K. Lehmann 1, Kathleen Brockdorf 1 and Dirk Neuber 2 1 phoenix x-ray Systems + Services Inc. St. Petersburg, FL, USA 2 phoenix x-ray Systems + Services

More information

Advanced Computed Tomography System for the Inspection of Large Aluminium Car Bodies

Advanced Computed Tomography System for the Inspection of Large Aluminium Car Bodies ECNDT 2006 - Th.3.4.2 Advanced Computed Tomography System for the Inspection of Large Aluminium Car Bodies M. SIMON, I. TISEANU, C. SAUERWEIN Hans WÄLISCHMILLER, Meersburg, Germany M. SINDEL, M. BRODMANN,

More information

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS 23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN 16-20 APRIL 2007 HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS P. Helberg 1,

More information

Process Monitoring using Three Dimensional Computed Tomography and Automatic Image Processing

Process Monitoring using Three Dimensional Computed Tomography and Automatic Image Processing ECNDT 2006 - We.3.7.1 Process Monitoring using Three Dimensional Computed Tomography and Automatic Image Processing Michael MAISL, Fraunhofer EZRT, Saarbrücken, Germany Stefan KASPERL, STEVEN OEKL, Fraunhofer

More information

Registration concepts for the just-in-time artefact correction by means of virtual computed tomography

Registration concepts for the just-in-time artefact correction by means of virtual computed tomography DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography, June 25-27, 2007, Lyon, France Registration concepts for the just-in-time artefact correction by means of virtual

More information

Methods for Quantitative Characterization of Large-Scale High Energy Computed Tomography Systems

Methods for Quantitative Characterization of Large-Scale High Energy Computed Tomography Systems More Info at Open Access Database www.ndt.net/?id=16704 Methods for Quantitative Characterization of Large-Scale High Energy Computed Tomography Systems Michael BÖHNEL 1, Andreas GRUBER 2, Nils REIMS 1,

More information

Fiber Composite Material Analysis in Aerospace Using CT Data

Fiber Composite Material Analysis in Aerospace Using CT Data 4th International Symposium on NDT in Aerospace 2012 - We.2.A.3 Fiber Composite Material Analysis in Aerospace Using CT Data Dr. Tobias DIERIG, Benjamin BECKER, Christof REINHART, Thomas GÜNTHER Volume

More information

Coordinate Measuring Machines with Computed Tomography

Coordinate Measuring Machines with Computed Tomography Always a Step Ahead with Quality Coordinate Measuring Machines with Computed Tomography Multisensor Coordinate Measuring Machines with Computed Tomography Computed Tomography in Coordinate Measuring Machines

More information

Process Monitoring using three dimensional Computed Tomography and Automatic Image Processing

Process Monitoring using three dimensional Computed Tomography and Automatic Image Processing DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography, June 25-27, 2007, Lyon, France Process Monitoring using three dimensional Computed Tomography and Automatic Image

More information

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE Rajesh et al. : Proceedings of the National Seminar & Exhibition on Non-Destructive Evaluation DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE Rajesh V Acharya, Umesh Kumar, Gursharan

More information

Frequency-based method to optimize the number of projections for industrial computed tomography

Frequency-based method to optimize the number of projections for industrial computed tomography More Info at Open Access Database www.ndt.net/?id=18739 Frequency-based method to optimize the number of projections for industrial computed tomography Andrea Buratti 1, Soufian Ben Achour 1, Christopher

More information

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection Caroline Vienne 1, Marius Costin 1 More info about this article: http://www.ndt.net/?id=21917 1 CEA, LIST, Département

More information

Fraunhofer Entwicklungszentrum Röntgentechnik, EZRT

Fraunhofer Entwicklungszentrum Röntgentechnik, EZRT Fraunhofer Entwicklungszentrum Röntgentechnik, EZRT Intelligent Sensor Systems for Nondestructive Testing regarding Product Life Cycle 2. Kolloquium des GRK 2075 Braunschweig 5. 6. Oktober 2017 Randolf

More information

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL Developments in Dimensional Metrology in X-ray Computed Tomography at NPL Wenjuan Sun and Stephen Brown 10 th May 2016 1 Possible factors influencing XCT measurements Components Influencing variables Possible

More information

Scaling Calibration in the ATRACT Algorithm

Scaling Calibration in the ATRACT Algorithm Scaling Calibration in the ATRACT Algorithm Yan Xia 1, Andreas Maier 1, Frank Dennerlein 2, Hannes G. Hofmann 1, Joachim Hornegger 1,3 1 Pattern Recognition Lab (LME), Friedrich-Alexander-University Erlangen-Nuremberg,

More information

Industrial Computed Tomography

Industrial Computed Tomography Industrial Computed Tomography YXLON International YXLON. The reason why 1 CT - applications YXLON. The reason why 2 CT - principles Computed Tomography (Line Detector) YXLON. The reason why 3 CT - principles

More information

Digital Volume Correlation for Materials Characterization

Digital Volume Correlation for Materials Characterization 19 th World Conference on Non-Destructive Testing 2016 Digital Volume Correlation for Materials Characterization Enrico QUINTANA, Phillip REU, Edward JIMENEZ, Kyle THOMPSON, Sharlotte KRAMER Sandia National

More information

Precise laser-based optical 3D measurement of welding seams under water

Precise laser-based optical 3D measurement of welding seams under water Precise laser-based optical 3D measurement of welding seams under water ISPRS/CIPA Workshop Underwater 3D Recording & Modeling" Piano di Sorrento (Napoli), Italy 16. 17. April 2015 Tanja Ekkel (M.Sc.)

More information

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China 7th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Image Registration Combining Digital Radiography and Computer-Tomography Image Data Frank HEROLD YXLON International X-Ray

More information

Case Studies in the Use of Computed Tomography for Non-Destructive Testing, Inspection and Measurement

Case Studies in the Use of Computed Tomography for Non-Destructive Testing, Inspection and Measurement SINCE2013 Singapore International NDT Conference & Exhibition 2013, 19-20 July 2013 Case Studies in the Use of Computed Tomography for Non-Destructive Testing, Inspection and Measurement Andrew A. MALCOLM,

More information

New Approach in Non- Contact 3D Free Form Scanning

New Approach in Non- Contact 3D Free Form Scanning New Approach in Non- Contact 3D Free Form Scanning Contents Abstract Industry Trends The solution A smart laser scanning system Implementation of the laser scanning probe in parts inspection Conclusion

More information

Quality control phantoms and protocol for a tomography system

Quality control phantoms and protocol for a tomography system Quality control phantoms and protocol for a tomography system Lucía Franco 1 1 CT AIMEN, C/Relva 27A O Porriño Pontevedra, Spain, lfranco@aimen.es Abstract Tomography systems for non-destructive testing

More information

Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset

Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset Andreas Maier 1, Patrick Kugler 2, Günter Lauritsch 2, Joachim Hornegger 1 1 Pattern Recognition Lab and SAOT Erlangen,

More information

Applications of Piezo Actuators for Space Instrument Optical Alignment

Applications of Piezo Actuators for Space Instrument Optical Alignment Year 4 University of Birmingham Presentation Applications of Piezo Actuators for Space Instrument Optical Alignment Michelle Louise Antonik 520689 Supervisor: Prof. B. Swinyard Outline of Presentation

More information

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography Characterization of microshells experimented on Laser Megajoule using X-Ray tomography More info about this article: http://www.ndt.net/?id=20881 Alexandre Choux, Lise Barnouin, Ludovic Reverdy, Marc Theobald

More information

PLANMECA PROMAX 3D MID CBCT UNIT

PLANMECA PROMAX 3D MID CBCT UNIT 1(5) PLANMECA PROMAX 3D MID CBCT UNIT Introduction The Planmeca ProMax 3D Mid X-ray unit uses cone beam computerized tomography (CBCT) to produce three-dimensional X-ray images. Panoramic and cephalometric

More information

Industrial Computer Tomography for Dimensional Metrology: Overview of Influence Factors and Improvement Strategies

Industrial Computer Tomography for Dimensional Metrology: Overview of Influence Factors and Improvement Strategies 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Industrial Computer Tomography for Dimensional Metrology: Overview of Influence Factors and

More information

Geometric Calibration in Active Thermography Applications

Geometric Calibration in Active Thermography Applications 19 th World Conference on Non-Destructive Testing 2016 Geometric Calibration in Active Thermography Applications Thomas SCHMIDT 1, Christoph FROMMEL 2 1, 2 Deutsches Zentrum für Luft- und Raumfahrt (DLR)

More information

Robot-Based Solutions for NDT Inspections: Integration of Laser Ultrasonics and Air Coupled Ultrasounds for Aeronautical Components

Robot-Based Solutions for NDT Inspections: Integration of Laser Ultrasonics and Air Coupled Ultrasounds for Aeronautical Components 19 th World Conference on Non-Destructive Testing 2016 Robot-Based Solutions for NDT Inspections: Integration of Laser Ultrasonics and Air Coupled Ultrasounds for Aeronautical Components Esmeralda CUEVAS

More information

The PolyCT Increasing the sample throughput using multiple rotation axes

The PolyCT Increasing the sample throughput using multiple rotation axes The PolyCT Increasing the sample throughput using multiple rotation axes More info about this article: http://www.ndt.net/?id=21946 1 Dr. Nicolas Thiemeyer, Johannes Leisner 2, Michael Salamon 2, Carina

More information

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM M. Simon, C. Sauerwein, I. Tiseanu, S. Burdairon Hans Wälischmiller GmbH Klingleweg 8, D-88709 Meersburg, Germany e-mail: ms@hwm.com ABSTRACT A new flexible

More information

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques SINCE2013 Singapore International NDT Conference & Exhibition 2013, 19-20 July 2013 Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image

More information

Reducing the influence of environmental scattering in industrial computed tomography by system optimisation and correction algorithms

Reducing the influence of environmental scattering in industrial computed tomography by system optimisation and correction algorithms 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16395 Reducing the influence of environmental

More information

Laminographic Inspection of Large Carbon Fibre Composite Aircraft-Structures at Airbus

Laminographic Inspection of Large Carbon Fibre Composite Aircraft-Structures at Airbus 19 th World Conference on Non-Destructive Testing 2016 Laminographic Inspection of Large Carbon Fibre Composite Aircraft-Structures at Airbus Oliver BULLINGER 1, Ulf SCHNARS 2, Daniel SCHULTING 1, Bernhard

More information

Robot-based real-time ultrasonic tomography for industrial NDT applications

Robot-based real-time ultrasonic tomography for industrial NDT applications 1 Robot-based real-time ultrasonic tomography for industrial NDT applications Dr. Andrey Bulavinov I-Deal Technologies GmbH 2 Content I. Introduction of I-Deal Technologies GmbH I-Deal Spin-Off of Fraunhofer-IZFP

More information

Increasing the accuracy with a rich sensor system for robotic laser osteotomy

Increasing the accuracy with a rich sensor system for robotic laser osteotomy Increasing the accuracy with a rich sensor system for robotic laser osteotomy Holger Mönnich moennich@ira.uka.de Daniel Stein dstein@ira.uka.de Jörg Raczkowsky rkowsky@ira.uka.de Heinz Wörn woern@ira.uka.de

More information

CIVA Computed Tomography Modeling

CIVA Computed Tomography Modeling CIVA Computed Tomography Modeling R. FERNANDEZ, EXTENDE, France S. LEGOUPIL, M. COSTIN, D. TISSEUR, A. LEVEQUE, CEA-LIST, France page 1 Summary Context From CIVA RT to CIVA CT Reconstruction Methods Applications

More information

Exterior Orientation Parameters

Exterior Orientation Parameters Exterior Orientation Parameters PERS 12/2001 pp 1321-1332 Karsten Jacobsen, Institute for Photogrammetry and GeoInformation, University of Hannover, Germany The georeference of any photogrammetric product

More information

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control Oliver BRUNKE 1,

More information

Dedicated Software Algorithms for 3D Clouds of Points

Dedicated Software Algorithms for 3D Clouds of Points Dedicated Software Algorithms for 3D Clouds of Points Introduction AQSENSE develops and commercializes 3D image acquisition and processing technologies that allow high speed in-line 100% production inspection,

More information

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape Tasuku Ito 1, Yutaka Ohtake 1, Yukie Nagai 2, Hiromasa Suzuki 1 More info about this article: http://www.ndt.net/?id=23662

More information

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube T. Donath* a, F. Pfeiffer a,b, O. Bunk a, W. Groot a, M. Bednarzik a, C. Grünzweig a, E. Hempel c, S. Popescu c, M. Hoheisel

More information

Novel Magnetic Field Mapping Technology for Small and Closed Aperture Undulators

Novel Magnetic Field Mapping Technology for Small and Closed Aperture Undulators Novel Magnetic Field Mapping Technology for Small and Closed Aperture Undulators Erik Wallen and Hyun-Wook Kim 06.06.2017 Outline Introduction - Measurement systems at LBNL - Activities at LBNL - Need

More information

Electronic angle measuring machine. Angle/position by means of vignetting

Electronic angle measuring machine. Angle/position by means of vignetting OPTIK MESS- UND PRÜFTECHNIK VERTRIEB BERATUNG TRAINING ELWIMAT Electronic angle measuring machine WiPoVi Angle/position by means of vignetting Biaxial optical angle measuring with great measuring range

More information

Z-MOTION. Universal Digital Radiographic System Z-MOTION. Control-X Medical CONTROL-X MEDICAL

Z-MOTION. Universal Digital Radiographic System Z-MOTION. Control-X Medical CONTROL-X MEDICAL Control-X Medical Z-MOTION Compact design, low ceiling height requirement Motorized and manual movement capability Wide motion / SID range Best-in-class image quality Flexible connectivity to PACS systems

More information

THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS

THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS A. Campos a*, A. Zorrilla a, F. Lasagni a a Materials & Processes dept., Center for Advanced Aerospace Technologies

More information

Suitability of a new alignment correction method for industrial CT

Suitability of a new alignment correction method for industrial CT Suitability of a new alignment correction method for industrial CT Matthias Elter 1, Nicole Maass 1, Peter Koch 2 1 Siemens AG, Healthcare Sector, Erlangen, Germany, e-mail: matthias.elter@siemens.com,

More information

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control 6 th International Congress of Metrology, 06003 (203) DOI: 0.05/ metrology/20306003 C Owned by the authors, published by EDP Sciences, 203 A new Concept for High-Speed atline and inlinect for up to 00%

More information

Seam tracking for fillet welds with scanner optics

Seam tracking for fillet welds with scanner optics Lasers in Manufacturing Conference 2015 Seam tracking for fillet welds with scanner optics Friedhelm Dorsch, Holger Braun, Dieter Pfitzner TRUMPF Laser- und Systemtechnik GmbH, Johann-Maus-Str. 2, 71254

More information

High-resolution X-ray CT Inspection of Honeycomb Composites Using Planar Computed Tomography Technology

High-resolution X-ray CT Inspection of Honeycomb Composites Using Planar Computed Tomography Technology 2nd International Symposium on NDT in Aerospace 2010 - We.4.B.4 High-resolution X-ray CT Inspection of Honeycomb Composites Using Planar Computed Tomography Technology Tong LIU, Andrew A. MALCOLM, and

More information

Multi-spectral (W, Mo, Cu, and Ag) XCT measurements

Multi-spectral (W, Mo, Cu, and Ag) XCT measurements Multi-spectral (W, Mo, Cu, and Ag) XCT measurements Marko Katić 1, Damir Markučič 1, Gorana Baršić 1 Faculty of mechanical engineering and naval architecture, Ivana Lucica 5, Zagreb, Croatia, marko.katic@fsb.hr

More information

UNITEST - A new device for the static and dynamic testing of unconventional machine structures

UNITEST - A new device for the static and dynamic testing of unconventional machine structures UNITEST - A new device for the static and dynamic testing of unconventional machine structures K.E. Meitz Department of Production Engineering, Technical University Graz, Kopernikusgasse 24, A-8010 Graz,

More information

Characterization of damage mechanisms in glass fibre reinforced polymers using X-ray computed tomography

Characterization of damage mechanisms in glass fibre reinforced polymers using X-ray computed tomography 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16410 Characterization of damage mechanisms

More information

Chapters 1 7: Overview

Chapters 1 7: Overview Chapters 1 7: Overview Chapter 1: Introduction Chapters 2 4: Data acquisition Chapters 5 7: Data manipulation Chapter 5: Vertical imagery Chapter 6: Image coordinate measurements and refinements Chapter

More information

Traceable 3D X-Ray Measurements ZEISS METROTOM

Traceable 3D X-Ray Measurements ZEISS METROTOM 20 Traceable 3D X-Ray Measurements With a computer tomograph, you can successfully perform measuring and inspection jobs yourself with only one X-ray scan. The standard acceptance test, the precision engineering

More information

XRADIA microxct Manual

XRADIA microxct Manual XRADIA microxct Manual Multiscale CT Lab Table of Contents 1. Introduction and Basics 1.1 Instrument Parts 1.2 Powering up the system 1.3 Preparing your sample 2. TXM Controller 2.1 Starting up 2.2 Finding

More information

Reconstruction Methods for Coplanar Translational Laminography Applications

Reconstruction Methods for Coplanar Translational Laminography Applications Reconstruction Methods for Coplanar Translational Laminography Applications U. EWERT, K.-U. THIESSENHUSEN, A. DERESCH, C. BELLON, S. HOHENDORF, S. KOLKOORI, N. WROBEL, B. REDMER, M. TSCHAIKNER, BAM, Berlin

More information

Planmeca ProMax 3D s CBCT unit

Planmeca ProMax 3D s CBCT unit D0010759 1(5) Planmeca ProMax 3D s CBCT unit Introduction The Planmeca ProMax 3D s X-ray unit uses cone beam computerized tomography (CBCT) to produce threedimensional X-ray images. Panoramic and cephalometric

More information

Wieblinger Weg 92a, Heidelberg, Germany, Phone: , Fax: ;

Wieblinger Weg 92a, Heidelberg, Germany, Phone: , Fax: ; HOW INDUSTRIAL COMPUTER TOMOGRAPHY ACCELERATES PRODUCT DEVELOPMENT IN THE LIGHT METAL CASTING AND INJECTION MOULDING INDUSTRY. Christof REINHART 1, Christoph POLIWODA 1, Thomas GÜNTHER 1 1 Volume Graphics

More information

UULA FOCALSPEC 3D LINE CONFOCAL SCANNER DID THEY TELL YOU THAT NO-ONE CAN MEASURE IT? WE CAN.

UULA FOCALSPEC 3D LINE CONFOCAL SCANNER DID THEY TELL YOU THAT NO-ONE CAN MEASURE IT? WE CAN. FocalSpec builds optical sensors to measure and inspect the quality of the advanced materials and devices in use today and currently in development for the future. Our sensors combine 3D topography, 3D

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60601-2-44 2001 AMENDMENT 1 2002-09 Amendment 1 Medical electrical equipment Part 2-44: Particular requirements for the safety of X-ray equipment for computed tomography Amendement

More information

Automatic Systems for Digitizing Historical Maps

Automatic Systems for Digitizing Historical Maps Martina Ballarin *, Caterina Balletti **, Caterina Gottardi *** Automatic Systems for Digitizing Historical Maps Keywords: digitization; robotic arm; 3D recording; photogrammetry; historical maps Summary:

More information

Radiographic Simulator artist: Version 2

Radiographic Simulator artist: Version 2 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Radiographic Simulator artist: Version 2 Carsten Bellon 1, Andreas Deresch 1, Christian Gollwitzer 1, Gerd-Rüdiger

More information

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon WHITE PAPER Introduction Introducing an image guidance system based on Cone Beam CT (CBCT) and a mask immobilization

More information

ADS40 Calibration & Verification Process. Udo Tempelmann*, Ludger Hinsken**, Utz Recke*

ADS40 Calibration & Verification Process. Udo Tempelmann*, Ludger Hinsken**, Utz Recke* ADS40 Calibration & Verification Process Udo Tempelmann*, Ludger Hinsken**, Utz Recke* *Leica Geosystems GIS & Mapping GmbH, Switzerland **Ludger Hinsken, Author of ORIMA, Konstanz, Germany Keywords: ADS40,

More information

X-ray Industrial Computed Laminography (ICL) Simulation Study of Planar Objects: Optimization of Laminographic Angle

X-ray Industrial Computed Laminography (ICL) Simulation Study of Planar Objects: Optimization of Laminographic Angle More info about this article: http://www.ndt.net/?id=21086 X-ray Industrial Computed Laminography (ICL) Simulation Study of Planar Objects: Optimization of Laminographic Angle Lakshminarayana Yenumula

More information

CT Systems and their standards

CT Systems and their standards CT Systems and their standards Stephen Brown Engineering Measurement 11 th April 2012 Industrial X-ray computed tomography: The future of co-ordinate metrology? Burleigh Court, Loughborough University

More information

A cone-beam CT geometry correction method based on intentional misalignments to render the projection images correctable

A cone-beam CT geometry correction method based on intentional misalignments to render the projection images correctable A cone-beam CT geometry correction method based on intentional misalignments to render the projection images correctable Felix Meli, Benjamin A. Bircher, Sarah Blankenberger, Alain Küng, Rudolf Thalmann

More information

High Resolution Phased Array Imaging using the Total Focusing Method

High Resolution Phased Array Imaging using the Total Focusing Method High Resolution Phased Array Imaging using the Total Focusing Method S. Kierspel, Wolfram A. Karl Deutsch, Helge Rast, Philippe Benoist 1, Venkat A 2 KARL DEUTSCH Pruef- und Messgeraetebau GmbH + Co KG

More information

CIVA CT, an advanced simulation platform for NDT

CIVA CT, an advanced simulation platform for NDT More Info at Open Access Database www.ndt.net/?id=18774 CIVA CT, an advanced simulation platform for NDT Marius Costin 1, David Tisseur 1, Caroline Vienne 1, Ronan Guillamet 1, Hussein Banjak 1, Navnina

More information

CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects

CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects Tong LIU 1, Brian Stephan WONG 2, Tai

More information

Deep Scatter Estimation (DSE): Accurate Real-Time Scatter Estimation for X-Ray CT using a Deep Convolutional Neural Network

Deep Scatter Estimation (DSE): Accurate Real-Time Scatter Estimation for X-Ray CT using a Deep Convolutional Neural Network Deep Scatter Estimation (DSE): Accurate Real-Time Scatter Estimation for X-Ray CT using a Deep Convolutional Neural Network Joscha Maier 1,2, Stefan Sawall 1,2, and Marc Kachelrieß 1,2 1 German Cancer

More information

Advanced Vision Guided Robotics. David Bruce Engineering Manager FANUC America Corporation

Advanced Vision Guided Robotics. David Bruce Engineering Manager FANUC America Corporation Advanced Vision Guided Robotics David Bruce Engineering Manager FANUC America Corporation Traditional Vision vs. Vision based Robot Guidance Traditional Machine Vision Determine if a product passes or

More information

Digital Shearographic Non-destructive Testing Laboratory

Digital Shearographic Non-destructive Testing Laboratory Digital Shearographic Non-destructive Testing Laboratory Digital Shearography is a laser technique which directly measures strain data in real time. Digital Shearography is insensitive to environmental

More information

3D X-ray Laminography with CMOS Image Sensor Using a Projection Method for Reconstruction of Arbitrary Cross-sectional Images

3D X-ray Laminography with CMOS Image Sensor Using a Projection Method for Reconstruction of Arbitrary Cross-sectional Images Ke Engineering Materials Vols. 270-273 (2004) pp. 192-197 online at http://www.scientific.net (2004) Trans Tech Publications, Switzerland Online available since 2004/08/15 Citation & Copright (to be inserted

More information

ZEISS Smartproof 5 Your Integrated Widefield Confocal Microscope for Surface Analysis in Quality Assurance and Quality Control

ZEISS Smartproof 5 Your Integrated Widefield Confocal Microscope for Surface Analysis in Quality Assurance and Quality Control Product Information Version 1.0 ZEISS Smartproof 5 Your Integrated Widefield Confocal Microscope for Surface Analysis in Quality Assurance and Quality Control Dedicated Design. Guided Workflow. Trusted

More information

STRAIGHT LINE REFERENCE SYSTEM STATUS REPORT ON POISSON SYSTEM CALIBRATION

STRAIGHT LINE REFERENCE SYSTEM STATUS REPORT ON POISSON SYSTEM CALIBRATION STRAIGHT LINE REFERENCE SYSTEM STATUS REPORT ON POISSON SYSTEM CALIBRATION C. Schwalm, DESY, Hamburg, Germany Abstract For the Alignment of the European XFEL, a Straight Line Reference System will be used

More information

Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography

Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography Natalia Grozmani 1, Andrea Buratti 1, Robert H. Schmitt 1 More info about this article:

More information

THREE DIMENSIONAL EXAMINATION OF DIRECTIVITY PATTERN IN IMMERSION TANK TESTING

THREE DIMENSIONAL EXAMINATION OF DIRECTIVITY PATTERN IN IMMERSION TANK TESTING 7 th International Symposium on NDT in Aerospace We.3.A.7 THREE DIMENSIONAL EXAMINATION OF DIRECTIVITY PATTERN IN IMMERSION TANK TESTING Daniel KOTSCHATE 1, Thomas HECKEL 1 and Dirk GOHLKE 1 1 Federal

More information

Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing

Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing Fraunhofer Institute for Production Technology, Aachen M. Sc. Guilherme Mallmann Prof. Dr.-Ing. Robert

More information

Linear, and segmented over up to 1000 points Squareness calibration Matrix compensation over up to 30 x 30 points

Linear, and segmented over up to 1000 points Squareness calibration Matrix compensation over up to 30 x 30 points ND 1404 Axes Encoder inputs* 4 (XYZQ)» 1 V PP or «TTL (other interfaces upon request) Subdivision factor* 10-fold (only for 1 V PP ) Display step 1) Display Functions Error compensation Data interface

More information

''VISION'' APPROACH OF CALmRATION METIIODS FOR RADIOGRAPHIC

''VISION'' APPROACH OF CALmRATION METIIODS FOR RADIOGRAPHIC ''VISION'' APPROACH OF CALmRATION METIIODS FOR RADIOGRAPHIC SYSTEMS Christophe Icord, Philippe Rizo, and Pascal Sire LETI - (CEA - Technologies avancees) DSYs/SETIA - CENG - 85X F-38041 Grenoble, Cedex

More information

Three-dimensional nondestructive evaluation of cylindrical objects (pipe) using an infrared camera coupled to a 3D scanner

Three-dimensional nondestructive evaluation of cylindrical objects (pipe) using an infrared camera coupled to a 3D scanner Three-dimensional nondestructive evaluation of cylindrical objects (pipe) using an infrared camera coupled to a 3D scanner F. B. Djupkep Dizeu, S. Hesabi, D. Laurendeau, A. Bendada Computer Vision and

More information

Planmeca ProMax 3D Max CBCT unit

Planmeca ProMax 3D Max CBCT unit D00107623 1(6) Planmeca ProMax 3D Max CBCT unit Introduction The Planmeca ProMax 3D Max X-ray unit uses cone beam computerized tomography (CBCT) to produce threedimensional X-ray images. Panoramic and

More information

Improved Inspection of Miniaturized Interconnections by Digital X-ray Inspection and Computed Tomography

Improved Inspection of Miniaturized Interconnections by Digital X-ray Inspection and Computed Tomography Eufanet 3D Workshop, Nov 28/29, 2011 Toulouse/France Improved Inspection of Miniaturized Interconnections by Digital X-ray Inspection and Computed Tomography Jens Lübbehüsen / Thomas Hemberger GE Sensing

More information

Non-Stationary CT Image Noise Spectrum Analysis

Non-Stationary CT Image Noise Spectrum Analysis Non-Stationary CT Image Noise Spectrum Analysis Michael Balda, Björn J. Heismann,, Joachim Hornegger Pattern Recognition Lab, Friedrich-Alexander-Universität Erlangen Siemens Healthcare, Erlangen michael.balda@informatik.uni-erlangen.de

More information

Image Acquisition Systems

Image Acquisition Systems Image Acquisition Systems Goals and Terminology Conventional Radiography Axial Tomography Computer Axial Tomography (CAT) Magnetic Resonance Imaging (MRI) PET, SPECT Ultrasound Microscopy Imaging ITCS

More information

AUTOMATED 4 AXIS ADAYfIVE SCANNING WITH THE DIGIBOTICS LASER DIGITIZER

AUTOMATED 4 AXIS ADAYfIVE SCANNING WITH THE DIGIBOTICS LASER DIGITIZER AUTOMATED 4 AXIS ADAYfIVE SCANNING WITH THE DIGIBOTICS LASER DIGITIZER INTRODUCTION The DIGIBOT 3D Laser Digitizer is a high performance 3D input device which combines laser ranging technology, personal

More information

Generalized Filtered Backprojection for Digital Breast Tomosynthesis Reconstruction

Generalized Filtered Backprojection for Digital Breast Tomosynthesis Reconstruction Generalized Filtered Backprojection for Digital Breast Tomosynthesis Reconstruction Klaus Erhard a, Michael Grass a, Sebastian Hitziger b, Armin Iske b and Tim Nielsen a a Philips Research Europe Hamburg,

More information

Introduction to Medical Imaging. Cone-Beam CT. Klaus Mueller. Computer Science Department Stony Brook University

Introduction to Medical Imaging. Cone-Beam CT. Klaus Mueller. Computer Science Department Stony Brook University Introduction to Medical Imaging Cone-Beam CT Klaus Mueller Computer Science Department Stony Brook University Introduction Available cone-beam reconstruction methods: exact approximate algebraic Our discussion:

More information

The new generation of industrial computed tomography. The Desktop CT exact S

The new generation of industrial computed tomography. The Desktop CT exact S The new generation of industrial computed tomography The Desktop CT S Volume scanning technology Innovation with a family tradition Founded in 1968, the family-owned, WEN- ZEL Metrology Group is one of

More information

ND 1300 QUADRA-CHEK the Digital Readouts for Convenient 2-D Measurement

ND 1300 QUADRA-CHEK the Digital Readouts for Convenient 2-D Measurement ND 1300 QUADRA-CHEK the Digital Readouts for Convenient 2-D Measurement The ND 1300 QUADRA-CHEK digital readouts can support up to four axes. They function as measuring computers with 2-D acquisition of

More information

Beam Analysis Camera Based Beam Propagation Analyzer: M Automatic M 2 - at Production Speeds. Manual M 2

Beam Analysis Camera Based Beam Propagation Analyzer: M Automatic M 2 - at Production Speeds. Manual M 2 3.7.1 Camera Based Beam Propagation Analyzer: M 2 ISO compliant Automatically measure your beam quality in under 1 minutes Tune your laser for best operation Specifically developed for continuous usage

More information