1 NI Vision NI Vision Builder for Automated Inspection Tutorial NI Vision Builder for Automated Inspection Tutorial August L-01

2 Support Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, addresses, and current events. National Instruments Corporate Headquarters North Mopac Expressway Austin, Texas USA Tel: For further support information, refer to the Technical Support and Professional Services appendix. To comment on National Instruments documentation, refer to the National Instruments website at ni.com/info and enter the Info Code feedback National Instruments. All rights reserved.

3 Important Information Warranty NI devices are warranted against defects in materials and workmanship for a period of one year from the invoice date, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor. The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in materials and workmanship, for a period of 90 days from the invoice date, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free. A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are covered by warranty. National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical accuracy. In the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent editions of this document without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. In no event shall National Instruments be liable for any damages arising out of or related to this document or the information contained in it. EXCEPT AS SPECIFIED HEREIN, NATIONAL INSTRUMENTS MAKES NO WARRANTIES, EXPRESS OR IMPLIED, AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. CUSTOMER S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF NATIONAL INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER. NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR DAMAGES RESULTING FROM LOSS OF DATA, PROFITS, USE OF PRODUCTS, OR INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE POSSIBILITY THEREOF. This limitation of the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service failures caused by owner s failure to follow the National Instruments installation, operation, or maintenance instructions; owner s modification of the product; owner s abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside reasonable control. Copyright Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation. National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction. End-User License Agreements and Third-Party Legal Notices You can find end-user license agreements (EULAs) and third-party legal notices in the following locations: Notices are located in the <National Instruments>\_Legal Information and <National Instruments> directories. EULAs are located in the <National Instruments>\Shared\MDF\Legal\license directory. Review <National Instruments>\_Legal Information.txt for more information on including legal information in installers built with NI products. Trademarks Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on National Instruments trademarks. ARM, Keil, and µvision are trademarks or registered of ARM Ltd or its subsidiaries. LEGO, the LEGO logo, WEDO, and MINDSTORMS are trademarks of the LEGO Group The LEGO Group. TETRIX by Pitsco is a trademark of Pitsco, Inc FIELDBUS FOUNDATION and FOUNDATION are trademarks of the Fieldbus Foundation. EtherCAT is a registered trademark of and licensed by Beckhoff Automation GmbH. CANopen is a registered Community Trademark of CAN in Automation e.v. DeviceNet and EtherNet/IP are trademarks of ODVA. Go!, SensorDAQ, and Vernier are registered trademarks of Vernier Software & Technology. Vernier Software & Technology and vernier.com are trademarks or trade dress. Xilinx is the registered trademark of Xilinx, Inc. Taptite and Trilobular are registered trademarks of Research Engineering & Manufacturing Inc. FireWire is the registered trademark of Apple Inc. Linux is the registered trademark of Linus Torvalds in the U.S. and other countries.

4 Handle Graphics, MATLAB, Real-Time Workshop, Simulink, Stateflow, and xpc TargetBox are registered trademarks, and TargetBox and Target Language Compiler are trademarks of The MathWorks, Inc. Tektronix, Tek, and Tektronix, Enabling Technology are registered trademarks of Tektronix, Inc. The Bluetooth word mark is a registered trademark owned by the Bluetooth SIG, Inc. The ExpressCard word mark and logos are owned by PCMCIA and any use of such marks by National Instruments is under license. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Other product and company names mentioned herein are trademarks or trade names of their respective companies. Members of the National Instruments Alliance Partner Program are business entities independent from National Instruments and have no agency, partnership, or joint-venture relationship with National Instruments. Patents For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. Export Compliance Information Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS (1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT INJURY TO A HUMAN. (2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY, COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND HARDWARE COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES, TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR MISUSES, OR ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE HEREAFTER COLLECTIVELY TERMED SYSTEM FAILURES ). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD NOT BE RELIANT SOLELY UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID DAMAGE, INJURY, OR DEATH, THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO PROTECT AGAINST SYSTEM FAILURES, INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS. BECAUSE EACH END-USER SYSTEM IS CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.

5 Contents About This Manual Related Documentation... x Chapter 1 Introduction to Vision Builder AI Vision Builder AI Configuration Interface Elements of the Configuration Interface Inspection State Diagram Vision Builder AI Inspection Interface Running an Inspection Configuration Interface Inspection Interface Chapter 2 Checking for the Presence of a Part Creating a New Inspection Acquiring Inspection Images Defining a Feature on which to Base a Coordinate System Setting a Coordinate System Checking for the Cap Using Measure Intensity Setting the Inspection Status Testing the Inspection Saving the Inspection Chapter 3 Inspecting Objects for Correct Measurements Creating a New Inspection Acquiring and Calibrating Inspection Images Locating Features to Measure Measuring Parts of the Gasket Setting the Inspection Status Testing the Inspection Saving the Inspection Chapter 4 Inspecting for Multiple Correct Instances of an Object Creating a New Inspection Acquiring Inspection Images Defining a Feature on which to Base a Coordinate System Setting a Coordinate System Measuring the Separation between Connectors National Instruments v

6 Contents Inspecting the Fuse Conductor Making Logical PASS/FAIL Decisions Setting the Inspection Status Testing the Inspection Saving the Inspection Chapter 5 Inspecting an Object that Spans Two Image Frames Creating a New Inspection Acquiring Inspection Images from Two Cameras Acquiring and Calibrating the Image of the Left Edge Acquiring and Calibrating the Image of the Right Edge Locating the Right Edge of the Part Switching Images Locating the Left Edge of the Part Calculating the Width of the Part Setting Calculator Step Inputs and Outputs Adding Operators and Constants Connecting the Equation Elements Making Logical PASS/FAIL Decisions with the Calculator Step Setting the Inspection Status Testing the Inspection Saving the Inspection Chapter 6 Branching and Decision Making Creating a New Inspection Creating the Inspection State Diagram Acquiring Inspection Images Checking for a Spray Bottle in the Image Checking for the Cap Using the Caliper Setting the Inspection Status Creating Custom Overlays for Inspection Configuring State Transitions Testing the Inspection Saving the Inspection Chapter 7 Looping and Variables Creating a New Inspection Creating the Inspection State Diagram Creating a Variable Acquiring Inspection Images Finding Pin Edges vi ni.com

7 NI Vision Builder for Automated Inspection Tutorial Initializing the Variable Indexing Measurements in a Result Array Setting a Coordinate System Checking the Pin Gap Updating the Variable Identifying Failed Pins Setting the Inspection Status Displaying the Current Inspection Image Configuring State Transitions Testing the Inspection Saving the Inspection Appendix A Technical Support and Professional Services Glossary National Instruments vii

8 About This Manual This manual contains many techniques for using NI Vision Builder for Automated Inspection (Vision Builder AI) to solve visual inspection tasks including inspection, gauging, part presence, guidance, and counting. Follow the instructions in this manual to familiarize yourself with Vision Builder AI and perform common inspection tasks. This manual contains the following chapters: Chapter 1, Introduction to Vision Builder AI, introduces the Vision Builder AI environment and describes how to run an inspection. Chapter 2, Checking for the Presence of a Part, introduces the Match Pattern, Measure Intensity, and Set Coordinate System steps. Follow the instructions in this chapter to create an inspection that checks for the presence of a spray bottle cap regardless of the bottle position in the inspection images. Chapter 3, Inspecting Objects for Correct Measurements, introduces image calibration, and the Detect Objects and Geometry steps. Follow the instructions in this chapter to create an inspection that measures the distance between holes in a gasket to verify that the gasket conforms to manufacturing specifications. Chapter 4, Inspecting for Multiple Correct Instances of an Object, introduces the Find Straight Edge, Caliper, and Decision Making steps. Follow the instructions in this chapter to create an inspection that measures the distance between the blade connectors of a fuse and checks the integrity of the fuse conductor regardless of the fuse position or whether the fuse is inverted. Chapter 5, Inspecting an Object that Spans Two Image Frames, introduces the Select Image and Calculator steps. Follow the instructions in this chapter to create an inspection that measures the width of a wooden plank that spans two images. Chapter 6, Branching and Decision Making, introduces the inspection state diagram and the Custom Overlay step. Follow the instructions in this chapter to create an inspection that checks the image for the presence of a spray bottle and, if a bottle is present, transitions to another state to determine if the bottle has a cap. If there is no spray bottle present in the image, the inspection moves on to the next image. Chapter 7, Looping and Variables, uses the inspection state diagram to implement a looping inspection and introduces the Set Variable and Array Operator steps. Follow the instructions in this chapter to create an inspection that inspects images of electronic components to determine if the distance between pins on the component is within a predetermined range. If the pin is too close or too far away from an adjacent pin, then the inspection fails. The inspection does not need to check every pin on the microchip before failing the inspection. The inspection fails at the first failed pin. National Instruments ix

9 About This Manual Related Documentation The following documents contain information that you might find helpful as you read this manual: NI Vision Builder for Automated Inspection Readme Contains information about the minimum system requirements, installation instructions, device support, and known issues for NI Vision Builder for Automated Inspection. The NI Vision Builder for Automated Inspection Readme is available at Start»All Programs»National Instruments» Vision Builder AI»Documentation. NI Vision Builder for Automated Inspection: Configuration Help Contains information about using the Vision Builder AI Configuration interface to create a machine vision application. NI Vision Builder for Automated Inspection: Configuration Help is available by selecting Help»Online Help from the Vision Builder AI Configuration interface. NI Vision Builder for Automated Inspection: Inspection Help Contains information about running applications created using Vision Builder AI in the Vision Builder AI Inspection Interface. NI Vision Builder for Automated Inspection: Inspection Help is available by selecting Help»Online Help from the Vision Builder AI Inspection interface. NI Developer Zone Visit ni.com/zone for the latest example programs, tutorials, technical presentations, and a community area where you can share ideas, questions, and source code with developers around the world. NI 17xx Smart Camera User Manual Describes the electrical and mechanical aspects of the NI 17xx smart camera, troubleshooting guidelines, and information about the LEDs, DIP switches, and connectors on the NI 17xx. NI 177x Smart Camera User Manual Describes the electrical and mechanical aspects of the NI 177x smart camera and information about the LEDs and connectors on the NI 177x. NI EVS-1463 User Manual Describes the electrical and mechanical aspects of the NI EVS-1463 embedded vision system, troubleshooting guidelines, and information about the LEDs, DIP switches, and connectors on the EVS-1463 device. NI EVS-1464 User Manual Describes the electrical and mechanical aspects of the NI EVS-1464 embedded vision system, troubleshooting guidelines, and information about the LEDs, DIP switches, and connectors on the EVS-1464 device. NI Smart Camera I/O Accessory User Guide Describes the features of the NI Smart Camera I/O Accessory, what you need to get started, and the installation and operation of the device. NI Vision Concepts Help Describes the basic concepts of image analysis, image processing, and machine vision. This document also contains in-depth discussions about imaging algorithms for advanced users. The NI Vision Concepts Help is available by selecting Start»All Programs»National Instruments»Vision Builder AI» Documentation»NI Vision Concepts Help from the Start menu. x ni.com

10 Introduction to Vision Builder AI 1 This chapter introduces the Vision Builder AI environment and describes how to run an inspection. Figures 1-1 and 1-2 show general instructions for creating a Vision Builder AI inspection. Figure 1-1 describes the basic steps for designing a Vision Builder AI inspection. The Add Inspection Steps module of Figure 1-1 is expanded in Figure 1-2. National Instruments 1-1

11 Chapter 1 Introduction to Vision Builder AI Figure 1-1. Instructions for Creating a Basic Vision Builder AI Inspection Start Open Vision Builder AI Configuration interface Add step to acquire an image of the parts under inspection Do you want to make measurements in real-world units? Yes Create or select a spatial calibration from the Calibration tab of the acquisition step No Do the parts appear in different locations from image to image? Yes Add step from Locate Features palette to locate the part in the image Add Set Coordinate System step to create a coordinate system based on the part location No Add Inspection steps Refer to Figure 1-2 for details. Do you want to create intermediate measurements based on the results of previous steps? Yes Add Calculator step No Do you want to customize the inspection decision? Yes Add Logic Calculator step or Calculator step No Add Set Inspection Status step Do you want to send measurements to an external device? No Yes Add one of the Communication steps Save inspection Stop 1-2 ni.com

12 NI Vision Builder for Automated Inspection Tutorial Figure 1-2. Adding Inspection Steps to a Vision Builder AI Inspection Does the image need to be enhanced? Yes Add Vision Assistant or Filter Image step No What type of inspection do you need to perform? Location Presence/ Absence Identification Gauging Add step from Locate Features palette. Add step from Check for Presence palette Add step from Identify Parts palette Do you want to measure distances between object edges? No Yes Add steps from Locate Features palette Add Caliper step Add Geometry step Do you want to add another step? Yes No National Instruments 1-3

13 Chapter 1 Introduction to Vision Builder AI Vision Builder AI Configuration Interface Vision Builder AI has two modes of operation: Configuration and Inspection. Use the Configuration interface to configure and test your inspection. Use the Inspection interface to deploy the software and perform online or offline visual inspection. Complete the following instructions to open the Vision Builder AI Configuration interface. 1. Select Start»All Programs»National Instruments»Vision Builder AI to launch Vision Builder AI. Note By default, My Computer is selected in the list of targets. When My Computer is selected Vision Builder AI runs on the development computer. 2. On the Vision Builder AI welcome screen, click New Inspection to open the Vision Builder AI Configuration Interface. Elements of the Configuration Interface Figure 1-3 shows the Vision Builder AI Configuration interface. The Configuration interface contains four areas: Main window, Overview window, Inspection Steps palette, and State Configuration window. 1-4 ni.com

14 NI Vision Builder for Automated Inspection Tutorial Figure 1-3. Vision Builder AI Configuration Interface Main Window 2 Overview Window 3 Inspection Steps Palette 4 State Configuration Window Main window Displays the image being processed, property pages for some inspection steps, or the state diagram for the inspection. Use the Main window to define regions of interest in an image, configure step parameters for some steps, and create/modify the state diagram for an inspection. Overview window Displays a thumbnail view of either the current inspection image or the state diagram for the inspection. Inspection Steps palette Lists and describes the steps that you use to create your inspection. When you click on most steps, the palette transforms into the property page for the step. State Configuration window Displays the list of steps in the currently selected state in the inspection. National Instruments 1-5

15 Chapter 1 Introduction to Vision Builder AI Inspection State Diagram Vision Builder AI uses a state diagram to define inspections with unique states and transitions that govern the execution flow of the inspection. Simple inspections can be defined using the single-state default inspection, shown in Figure 1-4. Figure 1-4. Default Inspection State Diagram More complex inspections can be created by adding additional states and transitions to the default state diagram. Figure 1-5 shows an example of an inspection that uses the state diagram to perform branching and looping in the inspection. Figure 1-5. Example of a Vision Builder AI Inspection State Diagram Within a state diagram, each state can lead to one or multiple states or can end the inspection cycle. Each state diagram relies on in-state calculations or user input to determine the next state to execute. Vision Builder AI executes the state diagram continuously from the Start point to the End point. Each state in an inspection is intended to contain a discrete set of inspection steps. To access the steps contained in a state, select the state on the state diagram. The steps present in the state will appear in the State Configuration window. The currently selected state is highlighted on the state diagram. Chapter 6, Branching and Decision Making, and Chapter 7, Looping and Variables, provide examples of using the state diagram. 1-6 ni.com

16 Vision Builder AI Inspection Interface NI Vision Builder for Automated Inspection Tutorial As mentioned in the Vision Builder AI Configuration Interface section of this chapter, use the Vision Builder AI built-in Inspection Interface to deploy and run an inspection. Figure 1-6 shows the built-in Inspection interface, which has three main areas: the Results panel, the Inspection Statistics panel, and the Display window. Figure 1-6. Vision Builder AI Built-in Inspection Interface 3 Results panel Lists the steps in the inspection by name. For each inspection step, Vision Builder displays the step type, result (PASS or FAIL), measurement made, and a comment explaining the reason of a FAIL. Inspection Status shows the result of the complete inspection. Display window Displays the part under inspection. Inspection Statistics panel Contains three indicators that display the yield (ratio between PASS and FAIL), active versus idle time, and processing time of the inspection. Running an Inspection Inspection Statistics Panel 2 Display Window 3 Results Panel Vision Builder AI allows you to run inspections from both the Configuration and Inspection interfaces. The following sections describe the options for running an inspection in Vision Builder AI. National Instruments 1-7

17 Chapter 1 Introduction to Vision Builder AI Configuration Interface Run an inspection from the Configuration interface during development to test and debug inspections. The Highlight Execution, Pause, and Single Step options are useful for debugging inspections. Table 1-1 lists the run options available for the Configuration interface: Table 1-1. Configuration Interface Run Modes Button Name Description Run Inspection Once Run Inspection in Loop Runs the inspection through one iteration of the state diagram. Runs the inspection continuously. Run Inspection Until Failure Runs the inspection until the Inspection Status variable has a value of FAIL. Run Inspection Multiple Times Stop Inspection Runs the inspection a specified number of times. This option is available only from the Operate menu. Stops the inspection. Highlight Execution Pause Step Into Step Over Use Previous Image Highlights the inspection execution when you run the inspection. If the Highlight Execution button appears yellow, execution highlighting is enabled. Pauses or resumes execution of the inspection. If the Pause button appears red, execution is paused. Steps through the inspection. Step Into is only available when the Pause button is pressed. Runs the current state. Step Over is only available when the Pause button is pressed. Uses the previous inspection image the next time the inspection executes. * 1-8 ni.com

18 NI Vision Builder for Automated Inspection Tutorial Table 1-1. Configuration Interface Run Modes (Continued) Button Name Description Use Current Image Uses the current inspection image the next time the inspection executes. * Use Next Image Select Next Image Uses the next inspection image the next time the inspection executes. * Specifies the inspection image to process the next time the inspection executes. * * This button applies only to inspections that either contain a Simulate Acquisition step, or have Simulate Smart Camera or Simulate Embedded Vision System selected as the target. Inspection Interface After an inspection is configured, use the Inspection interface to run the inspection and/or deploy your system. Complete the following instructions to run an inspection from the Inspection interface: Tip If the Vision Builder AI Configuration interface is already open, select File» Switch to Inspection Interface to open the current inspection in the Inspection interface. 1. Select Start»All Programs»National Instruments»Vision Builder AI to launch the Vision Builder AI. 2. On the Vision Builder AI welcome screen, click Browse under Run Inspection. 3. Select the inspection that you want to run and click OK to open the inspection in the Inspection Interface. National Instruments 1-9

19 Chapter 1 Introduction to Vision Builder AI 4. Click the Start Inspection button. Vision Builder AI begins running the inspection and updating the three areas of the Inspection interface with the most recent inspection data. By default, Vision Builder AI displays all the inspection images in the Display window. You can change the display settings in the View menu to view only images that fail or to have no display. You also can change the magnification of the displayed images in the Options menu. Notice the performance data displayed in the Inspection Statistics panel. This data can help you determine how efficiently your inspection is running. Based on this data, you can make adjustments to improve the inspection speed. 5. Click the Stop Inspection button to stop the inspection ni.com

20 Checking for the Presence of a Part 2 This chapter introduces the Match Pattern, Measure Intensity, and Set Coordinate System steps. Follow the instructions in this chapter to create an inspection that checks for the presence of a spray bottle cap regardless of the bottle position in the inspection images. Note Launch Vision Builder AI if it is not open. Refer to the Vision Builder AI Configuration Interface section of Chapter 1, Introduction to Vision Builder AI, for more information. Creating a New Inspection Select File»New to load a new, blank Vision Builder AI inspection. Acquiring Inspection Images In the Inspection Steps palette, the Acquire Images tab contains several acquisition steps you can use to acquire images from many different types of cameras. The tab also contains a Simulate Acquisition step, which simulates image acquisition by loading images from file. The Select Image step enables you to switch to a previously acquired image that you need to process later in the inspection. For simplicity, this tutorial instructs you to use the Simulate Acquisition step. However, in your real-world inspection, use one of the other image acquisition steps to acquire images of the object under inspection. Complete the following instructions to configure a Simulate Acquisition step that simulates acquiring images of spray bottles. 1. In the Inspection Steps palette, select the Acquire Images tab. 2. Click the Simulate Acquisition step. The property page for the step opens. National Instruments 2-1

21 Chapter 2 Checking for the Presence of a Part 3. In the Step Name control, enter Acquire Spray Bottle. 4. Click the Browse button. The Select an Image File dialog box opens. 5. Navigate to <Vision Builder AI>\DemoImg\Tutorial 1, where <Vision Builder AI> is the location where Vision Builder AI is installed. 6. Select the first image, Image 01.jpg, and click Open. 7. Make sure the Cycle Through Folder Images control is enabled so that Vision Builder AI loads a different simulation image from the folder each time the step is run. 8. Enable the Cache Images control if you want to load all of the images into memory when the inspection opens. By default, each image is loaded individually when the step executes. 9. Click OK to add the step to the inspection. Defining a Feature on which to Base a Coordinate System In a machine vision inspection, you typically limit your inspection and processing to a region of interest (ROI) rather than the entire image for the following reasons: To improve your inspection results by avoiding extraneous objects To increase inspection speed To limit the inspection area, the parts of the object you are interested in must always be inside the ROI you define. If the object under inspection is fixtured and always appears at the same location and orientation in the images you need to process, defining an ROI is straightforward. However, if the object under inspection appears shifted or rotated within the images, the regions of interest need to shift and rotate with the object under inspection. For the regions of interest to move in relation to the object, you need to set a coordinate system relative to a significant and original feature of the object under inspection. Choose a feature that is always in the field of view of the camera despite the different locations that the objects may appear in from image to image. Also, make sure the feature is not affected by major defects that could drastically modify the visual appearance of the feature. Complete the following instructions to configure a Match Pattern step that locates a bottle feature on which you can base a coordinate system. 1. In the Inspection Steps palette, select the Locate Features tab. 2-2 ni.com

22 NI Vision Builder for Automated Inspection Tutorial 2. Click the Match Pattern step. The NI Vision Template Editor opens. 3. Draw a rectangle around the base of the sprayer, as shown in Figure 2-1. This region becomes the pattern matching template. Figure 2-1. Creating a Template Pattern 4. Click Next. 5. Click Finish to accept the template. 6. On the Main tab, enter Locate Sprayer Base in the Step Name control. The green ROI specifies the area of the image in which Vision Builder AI tries to locate the template. Assuming that the bottles are fixtured in such a way that they can move only horizontally within the field of view, you can limit the ROI so that it surrounds only the area of the image that may contain a template match during inspection. National Instruments 2-3

23 Chapter 2 Checking for the Presence of a Part 7. Redraw or decrease the default green ROI so that it surrounds only the lower portion of the image, as shown in Figure 2-2. Figure 2-2. Limiting the Search Region 8. On the Template tab, drag the red crosshair mark in the template image to the left edge of the sprayer base, as shown in Figure 2-3. This changes the focal point of the template. The focal point indicates the part of the template that you want to return as the match location. By default, the focal point is the center of the template. You can modify the focal point by moving the red crosshair or by specifying a Match Offset. Later in this inspection, you use the match location as the origin of a coordinate system. 2-4 ni.com

24 NI Vision Builder for Automated Inspection Tutorial Figure 2-3. Adjusting the Focal Point of the Template 1 1 Focal Point 9. On the Settings tab, set Number of Matches to Find to On the Limits tab, enable the Minimum Number of Matches control, and set the value to Click OK to add the step to the inspection. Setting a Coordinate System Complete the following instructions to configure a Set Coordinate System step based on the Match Pattern step you configured. 1. In the Inspection Steps palette, select the Locate Features tab. 2. Click the Set Coordinate System step. The property page for the step opens. 3. On the Main tab, enter Coordinate System in the Step Name control. National Instruments 2-5

25 Chapter 2 Checking for the Presence of a Part 4. On the Settings tab, select Horizontal and Vertical Motion from the Mode control because the bottles appear shifted but not rotated from one image to another. Notice the Origin list. Match [1], the match location of the previous Locate Sprayer Base step, is the default origin of the coordinate system because it is the only location point created by previous steps in the inspection. 5. Click OK to add the step to the inspection. Checking for the Cap Using Measure Intensity The image of the spray bottle was acquired using a backlight. The cap appears dark on the bright background. Complete the following instructions to configure a Measure Intensity step to check for the presence of a spray bottle cap. 1. In the Inspection Steps palette, select the Measure Features tab. 2. Click the Measure Intensity step. The property page for the step opens. 3. On the Main tab, enter Check Cap Presence in the Step Name control. 4. Enable the Reposition Region of Interest control. Enabling this control allows you to link the regions of interest specified in this step to a previously defined coordinate system so that Vision Builder AI can adjust the location and orientation of the ROI from image to image relative to the specified coordinate system. The Reference Coordinate System list shows all the previously defined coordinate systems. Coordinate System is the default reference coordinate system because it is the only Set Coordinate System step in the current inspection. Notice that the Measure Intensity step supports a variety of different tools that enable you to draw different shaped regions of interest, such as a point, line, broken line, freehand line, rectangle, ellipse, annulus, polygon, and freehand region. These tools are available in the main menu bar. 2-6 ni.com

26 NI Vision Builder for Automated Inspection Tutorial 5. Using the default Rectangle Tool, hold down the <Ctrl> key, and draw three regions of interest that enclose edges of the cap, as shown in Figure 2-4. Pressing the <Ctrl> key enables you to draw multiple regions of interest for the step. Figure 2-4. Defining Regions in Which to Measure Intensity 6. Click the Limits tab. At the bottom of the Limits tab, Vision Builder AI returns the intensity statistics of the pixels inside the regions of interest. Pixel intensities can range from 0 through 255, where 0 equals black and 255 equals white. The Minimum Intensity value at the bottom of the page returns the lowest pixel value inside the regions of interest. The backlit edges of the plastic cap appear in silhouette as dark pixels (which have low pixel intensities) on a bright background (which has high pixel intensities). Therefore, when the cap is present, the minimum intensity for the regions is low. When the cap is not present, the minimum intensity for the regions is high because the regions contain only bright background pixels. 7. Enable the Minimum Intensity control. Set the Maximum value to Click OK to add the step to the inspection. National Instruments 2-7

27 Chapter 2 Checking for the Presence of a Part 9. Click the Run State Once button located in the State Configuration window. Vision Builder AI loads the next image, Image 02.jpg, from the <Vision Builder AI>\DemoImg\Tutorial 1 folder and runs the previous inspection steps in the state on the new image. Notice that the bottle appears closer to the left edge of the image. Vision Builder AI repositions the regions of interest based on the new location of the bottle. The Step Status for the image is PASS because the presence of the cap inside the regions of interest causes the Minimum Intensity value to fall within the limits you set. Setting the Inspection Status Complete the following instructions to add a Set Inspection Status step to determine whether the inspection passes or fails. 1. In the Inspection Steps palette, select the Use Additional Tools tab. 2. Click the Set Inspection Status step. The property page for the step opens. 3. In the Inspection Status control, select the Set to FAIL if any previous step fails option. 4. Click OK to add the step to the inspection. 2-8 ni.com

28 NI Vision Builder for Automated Inspection Tutorial Testing the Inspection Test the remaining images in the Tutorial 1 folder to make sure the inspection returns the correct results. Click the Run Inspection Once button to test the remaining images. Table 2-1 displays the expected results for each image. Table 2-1. Expected Results for the Spray Bottle Inspection Image Name Inspection Status Explanation Image 03.jpg PASS Cap is present. Image 04.jpg PASS Cap is present. Image 05.jpg FAIL Cap is missing. Saving the Inspection Complete the following instructions to save the example inspection. 1. Select File»Save or click the Save button on the toolbar. 2. Navigate to the location where you want to save the inspection. 3. In the File Name control, enter Tutorial 1.vbai. 4. Click Save to save the inspection. Tip Select File»Inspection Properties to add a short description or comments about the inspection. National Instruments 2-9

29 Inspecting Objects for Correct Measurements 3 This chapter introduces image calibration, and the Detect Objects and Geometry steps. Follow the instructions in this chapter to create an inspection that measures the distance between holes in a gasket to verify that the gasket conforms to manufacturing specifications. Note Launch Vision Builder AI if it is not open. Refer to the Vision Builder AI Configuration Interface section of Chapter 1, Introduction to Vision Builder AI, for more information. Creating a New Inspection Select File»New to load a new, blank Vision Builder AI inspection. Acquiring and Calibrating Inspection Images For simplicity, this tutorial instructs you to use the Simulate Acquisition step. However, in your real-world inspection, use one of the other image acquisition steps to acquire images of the object under inspection. Complete the following instructions to configure a Simulate Acquisition step that simulates acquiring images of gaskets. 1. In the Inspection Steps palette, select the Acquire Images tab. 2. Click the Simulate Acquisition step. The property page for the step opens. 3. In the Step Name control, enter Acquire Gasket. 4. Click the Browse button. The Select an Image File dialog box opens. National Instruments 3-1

30 Chapter 3 Inspecting Objects for Correct Measurements 5. Navigate to <Vision Builder AI>\DemoImg\Tutorial 2, where <Vision Builder AI> is the location where Vision Builder AI is installed. 6. Select the first image, Image 01.jpg, and click Open. 7. Make sure that the Cycle Through Folder Images control is enabled so that Vision Builder AI loads a different simulation image from the folder each time the step is run. By default, Vision Builder AI returns measurements in pixel units. If you want the inspection to return measurements in real-world units, you need to map pixel units to real-world units through a process called spatial calibration. 8. Click the Calibration tab. 9. Click Create Calibration to launch the calibration training interface. 10. In the Calibration Name control, enter Gasket Calibration. 11. Click Next. For this example, assume that the camera that acquired the inspection images is perpendicular to the image plane and lens distortion is negligible. Based on these assumptions, you can use Point Distance Calibration to calibrate your images. Point Distance Calibration transforms a pixel coordinate to a real-world coordinate through scaling in the x (horizontal) and y (vertical) directions. 12. Select the Point Distance Calibration option, and click Next. 13. Make sure that the current image is selected, and click Next. 3-2 ni.com

31 NI Vision Builder for Automated Inspection Tutorial 14. Carefully click the 0 mm and 50 mm markings on the ruler at the bottom of the image, as shown in Figure 3-1. Tip You may need to use the zoom buttons below the image to accurately click the ruler markings. After zooming in, scroll down to see the ruler at the bottom of the image. Figure 3-1. Specifying the Pixel Ratio 15. In the Distances control, enter 50 for the Real World value, and select millimeter for the Unit. 16. Click Next. 17. Ignore the Compute Lens Distortion Model option and click Next. In the Specify Calibration Axis step, you can define the origin and angle of the calibration axis anywhere in the image. By default, the top, left pixel in the image is the calibration axis origin, and the horizontal axis of the image is the calibration axis angle. Use the default calibration axis settings for this exercise. 18. Click Next. Tip In some applications, you may want to measure between a fixed reference feature on the part and other features in the image. Setting the origin of the calibration axis to the location of the reference feature simplifies making measurements because the starting point for the measurements becomes 0. National Instruments 3-3

32 Chapter 3 Inspecting Objects for Correct Measurements 19. Click OK to learn the calibration information and exit the calibration training interface. 20. Click OK to add the step to the inspection. Vision Builder AI saves the calibration in the following locations: (Windows XP/Server 2003 R2 (32-bit)) C:\Documents and Settings\All Users\Application Data\National Instruments\Vision Builder AI\ Calibration (Windows 7/Vista/Server 2008 R2) C:\ProgramData\National Instruments\ Vision Builder AI\Calibration Tip You can apply the learned calibration to all images acquired with the same camera at the same resolution. Locating Features to Measure Complete the following instructions to configure a Detect Objects step that finds small holes in the gasket. 1. In the Inspection Steps palette, select the Check for Presence tab. 2. Click the Detect Objects step. The property page for the step opens. 3. In the Step Name control, enter Detect Small Holes. 3-4 ni.com

33 NI Vision Builder for Automated Inspection Tutorial 4. Using the default Rectangle Tool, draw a region of interest (ROI) around the entire gasket, as shown in Figure 3-2. Figure 3-2. Defining the ROI 5. In the Threshold tab, select the Bright Objects option for the Look For control. Notice that the blue shading highlights all bright pixels pixels with high intensity values that fall within the Threshold Range in the ROI. Vision Builder AI groups contiguous highlighted pixels into objects, which are depicted by red bounding rectangles. National Instruments 3-5

34 Chapter 3 Inspecting Objects for Correct Measurements 6. Click the Settings tab. The step locates four objects, which are listed in Table 3-1. Depending on the location of the user-defined points previously configured in the calibration, the values for the Size (mm 2 ) may differ slightly from the values shown in Table 3-1. Table 3-1. Sizes of Gasket Holes Object Number Size (mm 2 ) Object 1 and Object 4 are the small holes of interest in this step. The following steps describe how to use the Minimum Object Size and Maximum Object Size controls of the Detect Objects step to eliminate objects of no interest based on their size. 7. Enable the Minimum Object Size and Maximum Object Size controls. Based on the information in Table 3-1, the small holes have sizes of mm 2 and mm Set Minimum Object Size to 50 and Maximum Object Size to In the Limits tab, enable the Minimum Number of Objects and Maximum Number of Objects controls. Set their values to Click OK to add the step to the inspection. Complete the following instructions to find the large hole in the gasket. 1. Right-click the Detect Small Holes step in the State Configuration window, and select Copy. 2. Right-click the Detect Small Holes step again. 3. Select Paste. A copy of the Detect Small Holes step is placed after the original step. 4. Double-click the Detect Small Holes copy or click the Edit Step button to launch the property page of the step for editing. 5. In the Step Name control, enter Detect Large Hole. 6. Select the Settings tab. Based on the information in Table 3-1, the large hole has a size of mm Set Minimum Object Size to 1300 and Maximum Object Size to ni.com

35 NI Vision Builder for Automated Inspection Tutorial 8. In the Limits tab, enable the Minimum Number of Objects and Maximum Number of Objects controls. Set their values to Click OK to add the step to the inspection. Measuring Parts of the Gasket Complete the following instructions to measure the distance from the top small hole to the large hole to inspect whether the distance meets specifications. Note Vision Builder AI returns the centers of mass for the holes as their locations. 1. In the Inspection Steps palette, select the Measure Features tab. 2. Click the Geometry step. The property page for the step opens. 3. In the Step Name control, enter Check Top Distance. 4. In the Geometric Feature control, select the Distance measurement. 5. Select points 1 and 3 by selecting the points from the Available Points list. 6. In the Limits tab, enable the Minimum Distance control and set it to 32. Enable the Maximum Distance control and set it to Click OK to add the step to the inspection. Complete the following instructions to measure the distance from the large hole to the bottom small hole to inspect whether the distance meets specifications. 1. Right-click the Top Distance step in the State Configuration window, and select Copy. 2. Right-click the Top Distance step again. 3. Select Paste. A copy of the Top Distance step is placed after the original step. 4. Double-click the Top Distance copy or click the Edit Step button to launch the property page of the step for editing. 5. In the Step Name control, enter Check Bottom Distance. 6. In the Geometric Feature control, select the Distance measurement. National Instruments 3-7

36 Chapter 3 Inspecting Objects for Correct Measurements 7. From the Available Points list, select 2 and 3, which correspond to the bottom small hole and large hole, respectively. 8. In the Limits tab, enable the Minimum Distance control and set it to 38. Enable the Maximum Distance control and set it to Click OK to add the step to the inspection. Setting the Inspection Status Complete the following instructions to add a Set Inspection Status step to determine whether the inspection passes or fails. 1. In the Inspection Steps palette, select the Use Additional Tools tab. 2. Click the Set Inspection Status step. The property page for the step opens. 3. In the Inspection Status control, select the Set to FAIL if any previous step fails option. 4. Click OK to add the step to the inspection. 3-8 ni.com

37 NI Vision Builder for Automated Inspection Tutorial Testing the Inspection Test the inspection to make sure it returns the results you expect. Click the Run Inspection Once button to run the inspection on each of the test images. Table 3-2 lists the test images, the inspection status to expect for each image, and an explanation of the status. Table 3-2. Expected Results for the Gasket Inspection Image Name Inspection Status Explanation Image 01.jpg PASS All steps passed. Image 02.jpg PASS All steps passed. Image 03.jpg PASS All steps passed. Image 04.jpg FAIL The Top Distance step failed because the distance between the holes is too small. Image 05.jpg FAIL The Detect Small Holes step failed because the bottom hole is missing. The missing hole also caused the Bottom Distance step to fail. Saving the Inspection Complete the following instructions to save the example inspection. 1. Select File»Save or click the Save button on the toolbar. 2. Navigate to the location where you want to save the inspection. 3. In the File Name control, enter Tutorial 2.vbai. 4. Click Save to save the inspection. Tip Select File»Inspection Properties to add a short description or comments about the inspection. National Instruments 3-9

38 Inspecting for Multiple Correct Instances of an Object 4 This chapter introduces the Find Straight Edge, Caliper, and Decision Making steps. Follow the instructions in this chapter to create an inspection that measures the distance between the blade connectors of a fuse and checks the integrity of the fuse conductor regardless of the fuse position or whether the fuse is inverted. Note Launch Vision Builder AI if it is not open. Refer to the Vision Builder AI Configuration Interface section of Chapter 1, Introduction to Vision Builder AI, for more information. Creating a New Inspection Select File»New to load a new, blank Vision Builder AI inspection. Acquiring Inspection Images For simplicity, this tutorial instructs you to use the Simulate Acquisition step. However, in your real-world inspection, use one of the other image acquisition steps to acquire images of the object under inspection. Complete the following instructions to configure a Simulate Acquisition step that simulates acquiring images of fuses. 1. In the Inspection Steps palette, select the Acquire Images tab. 2. Click the Simulate Acquisition step. The property page for the step opens. 3. In the Step Name control, enter Acquire Fuse. National Instruments 4-1

39 Chapter 4 Inspecting for Multiple Correct Instances of an Object 4. Click the Browse button. The Select an Image File dialog box opens. 5. Navigate to <Vision Builder AI>\DemoImg\Tutorial 3, where <Vision Builder AI> is the location where Vision Builder AI is installed. 6. Select the first image, Image 01.jpg, and click Open. 7. Make sure the Cycle Through Folder Images control is enabled so that Vision Builder AI loads a different simulation image from the folder each time the step is run. 8. Click OK to add the step to the inspection. Defining a Feature on which to Base a Coordinate System The fuses can appear shifted horizontally and slightly rotated from one inspection image to another. Complete the following instructions to configure a Find Straight Edge step that finds the left edge of the fuse so that regions of interest in subsequent steps can shift with the fuse. 1. In the Inspection Steps palette, select the Locate Features tab. 2. Click the Find Straight Edge step. The property page for the step opens. 3. In the Step Name control, enter Locate Fuse Left Edge. 4-2 ni.com

40 NI Vision Builder for Automated Inspection Tutorial 4. Draw a region of interest (ROI) across the left edge of the fuse, as shown in Figure 4-1. Figure 4-1. Finding a Straight Edge Notice that the ROI contains blue search lines. The step searches along the search lines for sharp transitions in pixel intensities, which usually represent object edges. The step fits a straight line through the individual detected edge points of each search line to determine the left edge of the fuse. 5. Click OK to add the step to the inspection. National Instruments 4-3

41 Chapter 4 Inspecting for Multiple Correct Instances of an Object Setting a Coordinate System Complete the following instructions to configure a Set Coordinate System step based on the Find Straight Edge step you configured. 1. In the Inspection Steps palette, select the Locate Features tab. 2. Click the Set Coordinate System step. The property page for the step opens. 3. In the Main tab, enter Set Coordinate System in the Step Name control. 4. In the Settings tab, select Horizontal Motion from the Mode control. Notice the Origin list. Point 1, the first point of the straight line detected by the Locate Fuse Left Edge step, is the default origin of the coordinate system. In this exercise, the location of the origin does not affect the measurement you need to make. Therefore, use the default origin. 5. Click OK to add the step to the inspection. Measuring the Separation between Connectors Complete the following instructions to configure a Caliper step that measures the distance between the blade connectors of the fuse. 1. In the Inspection Steps palette, select the Measure Features tab. 2. Click the Caliper step. The property page for the step opens. 3. In the Main tab, enter Measure Separation in the Step Name control. 4. Enable the Reposition Region of Interest control. 4-4 ni.com

42 5. Draw an ROI across the blade connectors, as shown in Figure 4-2. NI Vision Builder for Automated Inspection Tutorial Figure 4-2. Measuring the Distance Between Two Edges 6. In the Settings tab, select the Process named Vertical Min Caliper to change the direction and orientation of the caliper search lines. 7. In the Limits tab, enable the Minimum Distance control and set the value to 150. Enable the Maximum Distance control and set the value to Click OK to add the step to the inspection. National Instruments 4-5

43 Chapter 4 Inspecting for Multiple Correct Instances of an Object Inspecting the Fuse Conductor Complete the following instructions to configure Match Pattern steps that inspect the integrity of the fuse conductor. 1. In the Inspection Steps palette, select the Locate Features tab. 2. Click the Match Pattern step. The NI Vision Template Editor opens. 3. Draw an ROI around the conductor, as shown in Figure 4-3. This region becomes the pattern matching template. Figure 4-3. Creating a Template Pattern 4. Click Next. 5. Click Finish to accept the template. 6. On the Main tab, enter Match Conductor 1 in the Step Name control. 4-6 ni.com

44 7. Make sure the Reposition Region of Interest control is enabled. NI Vision Builder for Automated Inspection Tutorial 8. Redraw or decrease the default green ROI so that it surrounds an area slightly larger than the template, as shown in Figure 4-4. Figure 4-4. Limiting the Search Region 9. In the Settings tab, set Number of Matches to Find to Enable the Search for Rotated Patterns control. 11. Set the Angle Range +/- (degrees) control to 10 to enable the step to locate the best match possible within ±10 of the learned template angle. 12. In the Limits tab, enable the Minimum Number of Matches control and set the value to Click OK to add the step to the inspection. 14. Click the Run Inspection Once button twice so that Image 03.jpg becomes the active image. Note The name of the active image is displayed in the Acquire Fuse step in the State Configuration window. National Instruments 4-7

45 Chapter 4 Inspecting for Multiple Correct Instances of an Object A fuse may be inverted when Vision Builder AI acquires an image of the fuse. This inversion causes the conductor to look different than the template, shown in Figure 4-5a. To prevent a good but inverted fuse from failing inspection, you need to learn a pattern matching template for the inverted instances of the conductor as well, shown in Figure 4-5b. Figure 4-5. Valid Templates for the Conductor a. b. 15. In the Inspection Steps palette, select the Locate Features tab. 16. Click the Match Pattern step. The Select a template in the image dialog box opens. 17. Draw an ROI around the conductor, similar to the region you drew in step Click OK to learn the inverted template. 19. In the Step Name control, enter Match Conductor Set the Region of Interest control to Match Conductor 1. This configures the Match Conductor 2 step to use the same ROI that you previously defined for the Match Conductor 1 step. 21. In the Settings tab, set Number of Matches to Find to Enable the Search for Rotated Patterns control. 23. Set the Angle Range +/- (degrees) control to 10 to enable the step to locate the best match possible within ±10 of the learned template angle. 24. In the Limits tab, enable the Minimum Number of Matches control and set the value to Click OK to add the step to the inspection. 4-8 ni.com

46 Making Logical PASS/FAIL Decisions NI Vision Builder for Automated Inspection Tutorial In the previous lessons, the inspection would fail if any of the steps in the inspection failed. In this lesson, because the conductor under inspection can match only one of the patterns you specified, one of the Match Pattern steps always fails. If you were to set the Inspection Status to fail if any of the steps in the inspection fail, the entire inspection will always fail because one of the Match Pattern steps always fails. Using the Logic Calculator step, you can create a Boolean result that is based on the results of the previous inspection steps. The Set Inspection Status step can use this Boolean result to determine the Inspection Status. Complete the following instructions to configure a Logic Calculator step that causes the inspection to pass when the conductor matches either the template in Match Conductor 1 or Match Conductor 2, and when the Measure Separation step passes. 1. In the Inspection Steps palette, select the Use Additional Tools tab. 2. Click the Logic Calculator step. The property page opens in the Main window. 3. In the Step Name control, enter Decide Pass/Fail. 4. In the First Operand frame, set Source to Measure Separation. Set Measure to Step Status. Current Value displays the value of the measurement based on the current image. 5. Make sure Second Operand is set to Constant, and Constant is set to True. 6. Click Add to add this expression to the Expression table. 7. In the First Operand frame, set Source to Match Conductor 1. Set Measure to Step Status. 8. Make sure Second Operand is set to Constant, and Constant is set to True. 9. Click Add to add this expression to the Expression table. Notice the default binary operator AND in the last column of the Expression table. 10. In the First Operand frame, set Source to Match Conductor 2. Set Measure to Step Status. 11. Make sure Second Operand is set to Constant and Constant is set to True. 12. Click Add to add this expression to the Expression table. 13. Select the second expression in the Expression table, and click AND/OR to change the binary operator to OR. National Instruments 4-9

47 Chapter 4 Inspecting for Multiple Correct Instances of an Object 14. Hold down the <Shift> key, and select the second and third expressions in the Expression table. 15. Click () to group the expressions. The Logic Calculator property page should resemble Figure 4-6. Figure 4-6. Logic Calculator Property Page 16. Click OK to add the step to the inspection. Setting the Inspection Status Complete the following instructions to configure Vision Builder AI to pass the inspection when the Logic Calculator step passes, regardless of the results of individual steps in the inspection. 1. In the Inspection Steps palette, select the Use Additional Tools tab. 2. Click the Set Inspection Status step. The property page for the step opens. 3. In the Step Name control enter Set Inspection Status ni.com

48 NI Vision Builder for Automated Inspection Tutorial 4. In the Inspection Status control select the Set to measurement value option, and select Decide Pass/Fail - Step Status for the value. 5. Make sure the Update Number of Parts Inspected control is enabled. 6. Click OK to add the step to the inspection. Testing the Inspection Test the inspection to make sure it returns the results you expect. Click the Run Inspection Once button to test the remaining images. Table 4-1 lists the test images, the inspection status to expect for each image, and an explanation of the status. Table 4-1. Expected Results for the Fuse Inspection Image Name Inspection Status Explanation Image 01.jpg PASS All steps pass but one Match Pattern step. Image 02.jpg PASS All steps pass but one Match Pattern step. Image 03.jpg PASS All steps pass but one Match Pattern step. Image 04.jpg PASS All steps pass but one Match Pattern step. Image 05.jpg PASS All steps pass but one Match Pattern step. Image 06.jpg FAIL The Measure Separation step fails because the blade connectors are too close together. Image 07.jpg FAIL Both Match Pattern steps fail because the conductor is blown. Image 08.jpg FAIL Both Match Pattern steps fail because the conductor is melted. National Instruments 4-11

49 Chapter 4 Inspecting for Multiple Correct Instances of an Object Saving the Inspection Complete the following instructions to save the example inspection. 1. Select File»Save or click the Save button on the toolbar. 2. Navigate to the location where you want to save the inspection. 3. In the File Name control, enter Tutorial 3.vbai. 4. Click Save to save the inspection. Tip Select File»Inspection Properties to add a short description or comments about the inspection ni.com

50 Inspecting an Object that Spans Two Image Frames 5 This chapter introduces the Select Image and Calculator steps. Assume that you need to measure the width of a wide wooden plank with high accuracy. The only cameras available for the application have low pixel resolutions. To measure the width of a plank, you need to locate its left and right edges. If you were to set up the imaging system so both edges of a plank fit within an available camera s field of view, the resulting image detail would be too low to yield accurate measurements. Because the required image detail exceeds the pixel resolution capability of a single camera, two cameras per plank are needed one camera to acquire an image of the left edge and one camera to acquire an image of the right edge. Follow the instructions in this chapter to create an inspection that measures the width of a wooden plank that spans two images. Note Launch Vision Builder AI if it is not open. Refer to the Vision Builder AI Configuration Interface section of Chapter 1, Introduction to Vision Builder AI, for more information. Creating a New Inspection Select File»New to load a new, blank Vision Builder AI inspection. Acquiring Inspection Images from Two Cameras For simplicity, this tutorial instructs you to use the Simulate Acquisition step. However, in your real-world inspection, use one of the other image acquisition steps to acquire images of the object under inspection. National Instruments 5-1

51 Chapter 5 Inspecting an Object that Spans Two Image Frames Acquiring and Calibrating the Image of the Left Edge Complete the following instructions to configure Simulate Acquisition steps that simulate acquiring an image of the left section of the wooden plank and calibrating the image. 1. In the Inspection Steps palette, select the Acquire Images tab. 2. Click the Simulate Acquisition step. The property page for the step opens. 3. In the Step Name control, enter Acquire Plank (Left). 4. Click the Browse button. The Select an Image File dialog box opens. 5. Navigate to <Vision Builder AI>\DemoImg\Tutorial 4 Left, where <Vision Builder AI> is the location where Vision Builder AI is installed. 6. Select the first image, Image 01.jpg, and click Open. 7. Make sure that the Cycle Through Folder Images control is enabled so that Vision Builder AI loads a different simulation image from the folder each time the step is run. 8. Click the Calibration tab. 9. Click Create Calibration to launch the calibration training interface. 10. In the Calibration Name control, enter Plank Calibration (Left). 11. Click Next. For this example, assume that the camera that acquired the inspection images is perpendicular to the image plane and lens distortion is negligible. Based on these assumptions, you can use Point Distance Calibration to calibrate your images. Point Distance Calibration transforms a pixel coordinate to a real-world coordinate through scaling in the x (horizontal) and y (vertical) directions. 12. Select the Point Distance Calibration option, and click Next. 13. Make sure that the current image is selected, and click Next. 5-2 ni.com

52 NI Vision Builder for Automated Inspection Tutorial 14. Carefully click the 1 cm and 5 cm markings on the ruler at the bottom of the image, as shown in Figure 5-1. Tip You may need to use the zoom buttons below the image to accurately click the ruler markings. After zooming in, scroll down to see the ruler at the bottom of the image. Figure 5-1. Defining the Pixel to Real-World Ratio 15. In the Distances control, enter 4 for the Real World value, and select centimeter for the Unit. 16. Click Next. 17. Ignore the Compute Lens Distortion Model option and click Next. National Instruments 5-3

53 Chapter 5 Inspecting an Object that Spans Two Image Frames 18. In the Specify Calibration Axis step, click the 1 cm marking to define it as the origin of the calibration axis. Draw a line horizontally and to the right along the edge of the ruler to define the angle of the calibration axis, as shown in Figure 5-2. Figure 5-2. Defining the Origin and Angle of the Calibration Axis 19. Set the Axis Reference control to Direct. 20. Click Next. 21. Click OK to learn the calibration information and exit the calibration training interface. 22. Click OK to add the step to the inspection. Acquiring and Calibrating the Image of the Right Edge This section simulates acquiring an image of the right section of the wooden plank. Because the simulated acquisition represents a second camera, you cannot reuse the calibration that you created for the first camera. Complete the following instructions to configure Simulate Acquisition steps that simulate acquiring an image of the right section of the wooden plank and calibrating the image. 1. In the Inspection Steps palette, select the Acquire Images tab. 5-4 ni.com

54 NI Vision Builder for Automated Inspection Tutorial 2. Click the Simulate Acquisition step. The property page for the step opens. 3. In the Step Name control, enter Acquire Plank (Right). 4. Click the Browse button. The Select an Image File dialog box opens. 5. Navigate to <Vision Builder AI>\DemoImg\Tutorial 4 Right, where <Vision Builder AI> is the location where Vision Builder AI is installed. 6. Select the first image, Image 01.jpg, and click Open. 7. Make sure the Cycle Through Folder Images control is enabled so that Vision Builder AI loads a different simulation image from the folder each time the step is run. 8. Click the Calibration tab. 9. Click Create Calibration to launch the calibration training interface. 10. In the Calibration Name control, enter Plank Calibration (Right). 11. Click Next. Again, assume that the camera that acquired the inspection images is perpendicular to the image plane and lens distortion is negligible. 12. Select the Point Distance Calibration option, and click Next. 13. Make sure the current image is selected, and click Next. National Instruments 5-5

55 Chapter 5 Inspecting an Object that Spans Two Image Frames 14. Carefully click the 38 cm and 42 cm markings on the ruler at the bottom of the image, as shown in Figure Tip You may need to use the zoom buttons below the image to accurately click the ruler markings. After zooming in, scroll down to see the ruler at the bottom of the image. Figure 5-3. Defining the Pixel to Real-World Ratio 15. In the Distances control, enter 4 for the Real World value and select centimeter for the Unit. 16. Click Next. 17. Ignore the Compute Lens Distortion Model option and click Next. 5-6 ni.com

56 NI Vision Builder for Automated Inspection Tutorial 18. In the Specify Calibration Axis step, click the 38 cm marking to define it as the origin of the calibration axis. Draw a line horizontally and to the right along the edge of the ruler to define the angle of the calibration axis, as shown in Figure 5-4. Figure 5-4. Defining the Origin and Angle of the Calibration Axis 19. Set the Axis Reference control to Direct. 20. Click OK to learn the calibration information and exit the calibration training interface. 21. Click OK to add the step to the inspection. Locating the Right Edge of the Part Complete the following instructions to configure a Find Edges step that locates the right edge of the part. 1. In the Inspection Steps palette, select the Locate Features tab. 2. Click the Find Edges step. The property page for the step opens. National Instruments 5-7

57 Chapter 5 Inspecting an Object that Spans Two Image Frames 3. In the Step Name control, enter Find Right Edge. 4. Draw a line across the right edge of the part going from right to left, as shown in Figure 5-5. Tip Pressing the <Shift> key while drawing a line constrains the line tool to only draw horizontal or vertical lines. 5. Click the Settings tab. 6. In the Look for control, select First Edge. 7. In the Edge Polarity control, select Bright to Dark Only. Figure 5-5. Finding the Right Edge of the Plank Find Right Edge Notice the red square on the search line. The step searches along the search line for a sharp transition in pixel intensities, which usually represents an object edge. The red square marks the location of the right edge of the part. 8. Click OK to add the step to the inspection. 5-8 ni.com

58 NI Vision Builder for Automated Inspection Tutorial Switching Images Now that you have configured the inspection to locate the right edge of the wooden plank, you need to switch to the image of the left side of the plank. Complete the following instructions to configure a Select Image step that makes the image of the left side of the plank active for processing. 1. In the Inspection Steps palette, select the Acquire Images tab. 2. Click the Select Image step. The property page for the step opens. 3. In the Step Name control, enter Switch to Left Side. 4. In the Image Selection list, select Acquire Plank (Left). The image of the left side of the part appears in the Main window. 5. Click OK to add the step to the inspection. Locating the Left Edge of the Part Complete the following instructions to configure a Find Edges step that locates the left edge of the part. 1. In the Inspection Steps palette, select the Locate Features tab. 2. Click the Find Edges step. The property page for the step opens. 3. In the Step Name control, enter Find Left Edge. National Instruments 5-9

59 Chapter 5 Inspecting an Object that Spans Two Image Frames 4. Hold down the <Shift> key and draw a line across the left edge of the part going from left to right, as shown in Figure Click the Settings tab. 6. In the Look for control, select First Edge. 7. In the Edge Polarity control, select Bright to Dark Only. Figure 5-6. Finding the Left Edge of the Plank Find Left Edge The step searches along the search line and marks the location of the left edge with a red square. 8. Click OK to add the step to the inspection ni.com

60 Calculating the Width of the Part NI Vision Builder for Automated Inspection Tutorial Now that you have located the right edge of the part in one image and the left edge of the part in another image, you need to combine the measurements from the two images to determine the width of the part. Use the Calculator step to combine the two measurements and compute the width. Refer to the following equations as you configure the step. Right (LC) = Right (RC) +(Origin R - Origin L) (5-1) Part Width = Right (LC) - Left (LC) (5-2) where Right (LC) = The x position of the right edge in the calibration axis of the left edge. Right (RC) = The x position of the right edge in the calibration axis of the right edge. This corresponds to the calibrated x position result of the Find Right Edge step. Origin R = The x position of the origin in the calibration axis of the right edge. Origin L = The x position of the origin in the calibration axis of the left edge. Left (LC) = The x position of the left edge in the calibration axis of the left edge. This corresponds to the calibrated x position result of the Find Left Edge step. Setting Calculator Step Inputs and Outputs Complete the following instructions to configure a Calculator step to select the input measurements from the previous Find Right Edge and Find Left Edge steps, and create output results for the calculated values. 1. In the Inspection Steps palette, select the Use Additional Tools tab. 2. Click the Calculator step. The Calculator Setup Wizard opens. 3. Click Next to proceed with the wizard. Notice the Input Measurements list. The list contains all of the measurable data from each of the previous steps in the inspection. National Instruments 5-11

61 Chapter 5 Inspecting an Object that Spans Two Image Frames 4. Select the following measurements from the Input Measurements list: Find Right Edge»Edge [].X Position (Calibrated)»Edge [1].X Position (Calibrated) Find Left Edge»Edge [].X Position (Calibrated)»Edge [1].X Position (Calibrated) 5. Click Next. 6. Click Add New Output Result. A new output appears in the Output Results list. 7. In the Name control, enter Part Width. This output will contain the results of Equation Make sure Type is set to Numeric. 9. Click Add New Output Result again. 10. In the Name control, enter Right (LC). This output will contain the results of Equation Make sure Type is set to Numeric. 12. Click Finish to close the Calculator Setup Wizard. The Main window now displays a diagram with the measurement inputs and result outputs you specified in the Calculator Setup Wizard, as shown in Figure 5-7. The diagram also contains a default Boolean result named Step Result. You can connect the result of a computation to Step Result, which changes the status of the Calculator step to the result of the computation. Refer to the Making Logical PASS/FAIL Decisions with the Calculator Step section of this chapter for more information about Step Result. Figure 5-7. Calculator Diagram Elements Notice that the inputs and outputs are framed with color and have codes at the bottom of their frames. These colors and codes visually group inputs and outputs into their respective data types numerics, Booleans, or strings ni.com

62 NI Vision Builder for Automated Inspection Tutorial 13. To simplify the process of connecting the diagram elements later in this chapter, arrange the elements into the configuration shown in Figure 5-8 by dragging them to their new positions. Figure 5-8. Arranging Diagram Elements Adding Operators and Constants Earlier in this chapter, you used the Calibration Wizard to set calibration axis origins for the right and left sides of the part. These origins are the only elements of Equations 5-1 and 5-2 not yet represented in the Calculator diagram: (Origin R and Origin L). In step 18 of the Acquiring and Calibrating the Image of the Right Edge section of this chapter, you set the origin of the right side to the 38 cm marking of the imaged ruler. In step 18 of the Acquiring and Calibrating the Image of the Left Edge section of this chapter, you set the origin of the left side to the 1 cm marking of the imaged ruler. Therefore, (Origin R - Origin L) = 38-1 = 37. The distance between the calibration axis origins is a constant value. Add a constant with the value 37 to the Calculator diagram. 1. In the Functions palette, click Numeric. 2. Click the Num Const operator. Click inside the Calculator diagram below the Find Right Edge - Edge [1].X Position (Calibrated) input measurement to place the numeric constant on the Calculator diagram. 3. Double-click the numeric constant and type 37 to set the value of the constant. 4. Click the Add operator in the Functions palette. Click inside the Calculator diagram to the right of the Find Right Edge - Edge [1].X Position (Calibrated) input measurement. National Instruments 5-13

63 Chapter 5 Inspecting an Object that Spans Two Image Frames Tip Place the Add operator close enough to the Find Right Edge - Edge [1].X Position (Calibrated) input so that the Calculator step automatically connects the two elements with a wire. 5. Click the Show Help Window button on the Main tab of the Calculator step to launch the Help window, or click the Help button in the Calculator diagram toolbar. When you move your cursor over certain elements within the Calculator diagram, information about that item shows in the Help window. 6. Place your cursor over the Add operator. Notice in the Help window that the operator has an x input terminal, y input terminal, and x+y output terminal. 7. Click the Subtract operator in the Functions palette. Click inside the Calculator diagram to the right of the Find Left Edge - Edge [1].X Position (Calibrated) input measurement. Your Calculator diagram should look similar to the diagram shown in Figure 5-9. Figure 5-9. Unconnected Diagram Elements Connecting the Equation Elements Complete the following instructions to wire the diagram elements together such that they form Equation 5-1: Right (LC) = Right (RC) + (37). 1. Place your cursor on the small, triangular terminal located on the right side of the numeric constant. The cursor changes into a Wiring tool ni.com

64 NI Vision Builder for Automated Inspection Tutorial 2. Use the Wiring tool to click the terminal and release the mouse. As you move the cursor across the Calculator diagram, the Calculator step draws a wire between the terminal and the Wiring tool as though the wire were unwinding from a spool. 3. Without holding down the mouse button, move the cursor to the y input terminal of the Add operator. The y input terminal blinks. Use the Wiring tool to click the y input terminal and complete the connection. 4. Click the output terminal of the Add operator, and connect it to the input terminal of Right (LC). Tip If you do not terminate a wire correctly, the wire is broken and appears as a dashed black line with a red X in the middle. Click Remove Broken Wires in the Main tab to remove broken wires. Complete the following instructions to wire the diagram elements together such that they form Equation 5-2: Part Width = Right (LC) - Left (LC). 1. Place the cursor on the wire that connects the Add operator to Right (LC). The cursor changes into the Wiring tool. 2. Click the wire, and connect it to the x input terminal of the Subtract operator. 3. Click the Find Left Edge - Edge [1].X Position (Calibrated) output terminal, and connect it to the y input terminal of the Subtract operator. 4. Click the output terminal of the Subtract operator, and connect it to the input terminal of Part Width. Your connected Calculator diagram should look similar to the diagram shown in Figure Figure Connected Elements of Calculator Diagram 5. In the Calculator step property page, click the Measurements tab. 6. Click Compute Results to see the results of the calculation thus far. National Instruments 5-15

65 Chapter 5 Inspecting an Object that Spans Two Image Frames Making Logical PASS/FAIL Decisions with the Calculator Step Now that you have a created a diagram to measure the width of the part, you need a way to verify that the width meets manufacturing specifications. Complete the following instructions to add diagram elements that compare the measured width to minimum and maximum width tolerances and decide whether the plank passes inspection. 1. Click the up arrow in the Functions palette to return to the main palette. 2. Select the Comparison palette. 3. Click the Less? operator in the Comparison palette. Click inside the Calculator diagram below Part Width. 4. Connect the wire between Subtract and Part Width to the x input of the Less? operator. 5. Click the up arrow in the Functions palette to return to the main palette. 6. Select the Numeric palette. 7. Click the Num Const operator in the Numeric palette. 8. Click close enough to the y input of Less? to automatically wire the numeric constant and y input together. 9. Type 40.5 to set the maximum width a plank can be to pass the inspection. 10. Click the up arrow in the Functions palette to return to the main palette. 11. Select the Comparison palette. 12. Click the Greater? operator. Click inside the Calculator diagram below the Less? operator. 13. Connect the wire between Subtract and Part Width to the x input of the Greater? operator. 14. Click the up arrow in the Functions palette to return to the main palette. 15. Select the Numeric palette. 16. Click the Num Const operator. 17. Click close enough to the y input of Greater? to automatically wire the numeric constant and y input together. 18. Type 39.5 to set the minimum width a plank can be to pass the inspection. 19. Click the up arrow in the Functions palette to return to the main palette. 20. Select the Boolean palette. 21. Click the And operator. Click close enough to the left side of Step Result to wire the two elements together. 22. Connect the Less? output to the x input of And. 23. Connect the Greater? output to the y input of And ni.com

66 NI Vision Builder for Automated Inspection Tutorial Your completed Calculator diagram should look similar to the diagram shown in Figure Figure Calculator Diagram with Decision-Making Abilities 24. In the Calculator step property page, click the Limits tab. 25. Enable the Step Result is True checkbox. 26. Click OK to add the step to the inspection. Setting the Inspection Status Complete the following instructions to add a Set Inspection Status step to determine whether the inspection passes or fails. 1. In the Inspection Steps palette, select the Use Additional Tools tab. 2. Click the Set Inspection Status step. The property page for the step opens. 3. In the Inspection Status control, Select the Set to FAIL if any previous step fails option. 4. Click OK to add the step to the inspection. National Instruments 5-17

67 Chapter 5 Inspecting an Object that Spans Two Image Frames Testing the Inspection Test the inspection to make sure it returns the results you expect. Click the Run Inspection Once button to test the remaining images. Table 5-1 lists the test images, the inspection status to expect for each image, and an explanation of the status. Note Results may vary slightly based on the accuracy of the calibration and the edge detection location. Table 5-1. Expected Results for the Plank Inspection Image Name Part Width Inspection Status Image 01.jpg cm PASS Image 02.jpg cm PASS Image 03.jpg cm PASS Image 04.jpg cm (too short) FAIL Image 05.jpg cm (too long) FAIL Saving the Inspection Complete the following instructions to save the example inspection. 1. Select File»Save or click the Save button on the toolbar. 2. Navigate to the location where you want to save the inspection. 3. In the File Name control, enter Tutorial 4.vbai. 4. Click Save to save the inspection. Tip Select File»Inspection Properties to add a short description or comments about the inspection ni.com

68 Branching and Decision Making 6 This chapter introduces the inspection state diagram and the Custom Overlay step. Follow the instructions in this chapter to create an inspection that checks the image for the presence of a spray bottle and, if a bottle is present, transitions to another state to determine if the bottle has a cap. If there is no spray bottle present in the image, the inspection moves on to the next image. Note Launch Vision Builder AI if it is not open. Refer to the Vision Builder AI Configuration Interface section of Chapter 1, Introduction to Vision Builder AI, for more information. Creating a New Inspection Select File»New to load a new, blank Vision Builder AI inspection. Creating the Inspection State Diagram The configurable process model in Vision Builder AI is represented by a state diagram. Complete the following instructions to create a state diagram to define the inspection. 1. Click the Toggle Main Window View button on the toolbar to bring the state diagram to the Main window. Figure 6-1. Default Inspection State Diagram National Instruments 6-1

69 Chapter 6 Branching and Decision Making 2. Double-click the Inspect state to launch the Edit State Name dialog box. 3. In the State Name control, enter Check Part Presence, and click OK. 4. Right-click an open area on the state diagram and select Create New State to add a new state to the inspection, as shown in Figure 6-2. The Edit State Name dialog box opens. Figure 6-2. Creating a New Inspection State 5. In the State Name control, enter Inspect Part. 6. Create two more states named Fail Part and Pass Part. The state diagram should now resemble the state diagram shown in Figure 6-3. Figure 6-3. Adding New States to the Inspection Next, you will create transitions between the various inspection states. Notice that every state has a default transition. You can also create additional transitions between states based on measurement results or variable values. 6-2 ni.com

70 NI Vision Builder for Automated Inspection Tutorial Note The default transition occurs if the transition requirements for other possible transitions are not met. 7. Click the arrow of the Check Part Presence default transition and drag it back to the Check Part Presence state. This creates a loop that will run the steps in the Check Part Presence State until a part is detected. 8. Click the End point and drag it to the bottom of the state diagram. 9. Click the Inspect Part default transition and drag it to the Fail Part state. 10. Click the Fail Part default transition and drag it to the End point. 11. Click the Pass Part default transition and drag it to the End point. The state diagram should now resemble the state diagram shown in Figure 6-4. Figure 6-4. Configuring the Default Transitions 12. Right-click the Check Part Presence state and select Create New Transition. National Instruments 6-3

71 Chapter 6 Branching and Decision Making 13. Click the Inspect Part state to create a transition between the Check Part Presence and Inspect Parts states, as shown in Figure 6-5. Figure 6-5. Creating a New Transition You can change the shape of the transition by dragging the anchor point at the center of the transition. You can move the location of the transition label by clicking the label and dragging it to the new location. Tip When drawing a transition, click once on the state diagram to set the anchor point for the transition. The anchor point allows you to draw an arc instead of a straight line to represent the transition. 14. Double-click the transition to launch the Edit Transition dialog box, which is used to configure the transition. 15. In the Transition Name control, enter Part Detected, and click OK. 16. Create another transition named Part OK between the Inspect Part and Pass Part states. 6-4 ni.com

72 NI Vision Builder for Automated Inspection Tutorial The state diagram should now resemble the state diagram shown in Figure 6-6. Figure 6-6. Completed State Diagram for the Inspection Note You can remove a state or transition from the inspection by selecting the object you want to remove and pressing the <Delete> key. Note You cannot rename or remove the default transition of a state. Each state in an inspection is intended to contain a separate set of inspection steps. To access the functions in a state, click the state in the state diagram. The currently selected state is highlighted in blue on the state diagram. Acquiring Inspection Images For simplicity, this tutorial instructs you to use the Simulate Acquisition step. However, in your real-world inspection, use one of the other image acquisition steps to acquire images of the object under inspection. Complete the following instructions to configure a Simulate Acquisition step that simulates acquiring images of spray bottles. 17. On the state diagram, click the Check Part Presence state. National Instruments 6-5

73 Chapter 6 Branching and Decision Making 18. In the Inspection Steps palette, select the Acquire Images tab. 19. Click the Simulate Acquisition step. The property page for the step opens. Note When the property page for an inspection step opens, if the state diagram is displayed in the Main window, the state diagram switches from the Main window to the Overview window to allow you to use the current inspection image to configure the step. 20. In the Step Name control, enter Acquire Image. 21. Click the Browse button. The Select an Image File dialog box opens. 22. Navigate to <Vision Builder AI>\DemoImg\Tutorial 5, where <Vision Builder AI> is the location where Vision Builder AI is installed. 23. Select an image containing the entire spray bottle, such as Image jpg, and click Open. 24. Make sure the Cycle Through Folder Images control is enabled so that Vision Builder AI loads a different simulation image from the folder each time the step is run. 25. Click OK to add the step to the inspection. Checking for a Spray Bottle in the Image Complete the following instructions to configure a Match Pattern step to check for the presence of a spray bottle in the image. 1. In the Inspection Steps palette, select the Locate Features tab. 2. Click the Match Pattern step. The NI Vision Template Editor opens. 3. Draw a region of interest (ROI) around the bottom left edge of the bottle. This region becomes the pattern matching template. 6-6 ni.com

74 4. Click Next. 5. Click Finish to accept the template. NI Vision Builder for Automated Inspection Tutorial 6. On the Main tab, enter Locate Bottle in the Step Name control. 7. Adjust the default green ROI so that it only surrounds the area of the image that could contain the bottom left edge of a spray bottle, as shown in Figure 6-7. Figure 6-7. Adjusting the Search Region 8. On the Settings tab, set the Number of Matches to Find control to On the Limits tab, enable the Minimum Number of Matches control, and set the value to Click OK to add the step to the inspection. Checking for the Cap Using the Caliper You can check for the presence of the cap on a spray bottle by using the Caliper step to find two edges where the cap is supposed to be and measuring the distance between them. Complete the following instructions to configure a Caliper step to check for the presence of the spray bottle cap. 1. In the Overview window, click the Inspect Part state on the state diagram. National Instruments 6-7

75 Chapter 6 Branching and Decision Making 2. In the Inspection Steps palette, select the Measure Features tab. 3. Click the Caliper step. The property page for the step opens. 4. In the Step Name control, enter Check Cap Presence. 5. Draw an ROI around the area in the image where a cap should appear, as shown in Figure 6-8. Figure 6-8. Checking for Cap Presence 6. On the Settings tab, select the Process named Horizontal Max Caliper to change the direction and orientation of the caliper search lines. 7. Set the Gap control to 10, Edge Strength to 40, and Smoothing to 12 to ensure that the step correctly detects the edges of the cap. 6-8 ni.com

76 NI Vision Builder for Automated Inspection Tutorial 8. On the Limits tab, enable the Minimum Distance control, and set the value to Enable the Maximum Distance control, and set the value to Click OK to add the step to the inspection. Setting the Inspection Status Complete the following instructions to add a Set Inspection Status step to determine whether the inspection passes or fails. 1. In the Inspection Steps palette, click the Use Additional Tools tab. 2. Click the Set Inspection Status step. The property page for the step opens. 3. In the Inspection Status control, select the Set to FAIL if any previous step fails option. 4. Click OK to add the step to the inspection. Creating Custom Overlays for Inspection Use the Custom Overlay step to create custom overlays that display whether the inspection passed or failed. Complete the following steps to create an overlay to display when the inspection fails. 1. In the Overview window, click the Fail Part state on the state diagram. 2. In the Inspection Steps palette, select the Use Additional Tools tab. 3. Click the Custom Overlay step. The property page for the step opens. 4. In the Step Name control, enter Overlay Results. National Instruments 6-9

77 Chapter 6 Branching and Decision Making 5. On the Custom Overlay tab, select the Text tool and click a point in the image near the bottom of the spray nozzle of the bottle. 6. In the Text Control, enter Missing Cap!. 7. Click the Text Properties button. The Text Properties dialog box opens. 8. In the Desired Font control, select User-Specified Font. 9. Specify a Font Name and Size to use for the overlay. 10. In the Horizontal Alignment control, select Center. This centers the text around the point you selected using the Text tool. 11. Click OK to save the Text Properties settings and close the dialog box. 12. Click OK to add the step to the inspection. Next, you need to create an overlay to display if the inspection passes. Complete the following steps to create an overlay to display when the inspection passes. 13. In the Overview window, click the Pass Part state on the state diagram. 14. In the Inspection Steps palette, select the Use Additional Tools tab. 15. Click the Custom Overlay step. The property page for the step opens. 16. In the Step Name control, enter Overlay Results. 17. On the Custom Overlay tab, select the Rectangle tool and draw a rectangle in the upper-left corner of the image. 18. Click the Stroke control, and select black. 19. Click the Fill control, and select a bright green color ni.com

78 NI Vision Builder for Automated Inspection Tutorial 20. On the Custom Overlay tab, select the Text tool, and click a point just below the center of the rectangle overlay. 21. In the Text control, enter Part OK. 22. Click the Text color control, and select black. 23. Click the Text Properties button. The Text Properties dialog box appears. 24. In the Desired Font control, select User-Specified Font. 25. Specify a Font Name and Size to use for the overlay. 26. In the Horizontal Alignment control, select Center. 27. Click OK to save the Text Properties settings and close the dialog box. 28. Click OK to add the step to the inspection. Figure 6-9 shows the overlays for both Pass and Fail images. Figure 6-9. Creating Custom Overlays for Images that Pass and Fail National Instruments 6-11

79 Chapter 6 Branching and Decision Making Configuring State Transitions Once you have configured all of the states in the inspection and created transitions between the states, you need to define the conditions that trigger a transition between inspection states. Complete the following instructions to define the transitions between inspection states. 1. Click the Toggle Main Window View button to display the state diagram in the Main window. 2. Double-click the Part Detected transition to launch the Edit Transition dialog box, which is used to configure the transition. 3. In the Edit Transition dialog box, modify the controls to transition when Locate Bottle - # Matches is Equal to 1, as shown in Figure Figure Configuring the Part Detected Transition 4. Click OK to close the Edit Transition dialog box. 5. Double-click the Part OK transition. The Edit Transition dialog box opens ni.com

80 NI Vision Builder for Automated Inspection Tutorial 6. In the Edit Transition dialog box, modify the controls to transition when Check Cap Presence - Step Status is Pass, as shown in Figure Figure Configuring the Part OK Transition 7. Click OK to close the Edit Transition dialog box. Testing the Inspection Test the images in the Tutorial 5 folder to make sure the inspection returns the correct results. Click the Run Inspection Once button to test the remaining images. Table 6-1 displays the expected results for each image. Table 6-1. Expected Results for the State Diagram Branching Inspection Image Name Inspection Status Explanation Image jpg PASS Cap is present. Image jpg PASS Cap is present Image jpg FAIL Cap is missing. Image jpg PASS Cap is present. National Instruments 6-13

81 Chapter 6 Branching and Decision Making Saving the Inspection Complete the following instructions to save the example inspection. 1. Select File»Save or click the Save button on the toolbar. 2. Navigate to the location where you want to save the inspection. 3. In the File Name control, enter Tutorial 5.vbai. 4. Click Save to save the inspection. Tip Select File»Inspection Properties to add a short description or comments about the inspection ni.com

82 Looping and Variables 7 This chapter uses the inspection state diagram to implement a looping inspection and introduces the Set Variable and Array Operator steps. Follow the instructions in this chapter to create an inspection that inspects images of electronic components to determine if the distance between pins on the component is within a predetermined range. If the pin is too close or too far away from an adjacent pin, then the inspection fails. The inspection does not need to check every pin on the microchip before failing the inspection. The inspection fails at the first failed pin. Note Launch Vision Builder AI if it is not open. Refer to the Vision Builder AI Configuration Interface section of Chapter 1, Introduction to Vision Builder AI, for more information. Creating a New Inspection Select File»New to load a new, blank Vision Builder AI inspection. Creating the Inspection State Diagram Complete the following instructions to create a state diagram to define the inspection. 1. Click the Toggle Main Window View button on the toolbar to bring the inspection state diagram to the Main window. 2. Double-click the Inspect state to launch the Edit State Name dialog box. 3. In the State Name control, enter Acquire Image & Find Pin Edges. National Instruments 7-1

83 Chapter 7 Looping and Variables 4. Right-click an open area on the state diagram and select Create New State to add a new state to the inspection, as shown in Figure 7-1. The Edit State Name dialog box opens. Figure 7-1. Creating a New Inspection State 5. In the State Name control, enter Check Pin Gap. 6. Create two more states named Fail Inspection and Pass Inspection. The state diagram should now resemble the state diagram shown in Figure 7-2. Figure 7-2. Adding New States to the Inspection Next, you will define transitions between the various inspection states. Notice that every state has a default transition. You can also create additional transitions between states based on measurement results or variable values. Note The default transition occurs if the transition requirements for other possible transitions are not met. 7-2 ni.com

84 NI Vision Builder for Automated Inspection Tutorial 7. Click the Acquire Image & Find Pin Edges default transition and drag it to the Check Pin Gap state. 8. Click the End point and drag it to the bottom of the state diagram. 9. Click the Check Pin Gap state default transition and drag it to the Pass Inspection state. 10. Click the Fail Inspection default transition and drag it to the End point. 11. Click the Pass Inspection default transition and drag it to the End point. The state diagram should now resemble the state diagram shown in Figure 7-3. Figure 7-3. Configuring the Default Transitions 12. Right-click the Acquire Image & Find Pin Edges state and select Create New Transition. National Instruments 7-3

85 Chapter 7 Looping and Variables 13. Click the Fail Inspection state to create a transition between the Acquire Image & Find Pin Edges state and the Fail Inspection state, as shown in Figure 7-4. Figure 7-4. Creating a New Transition You can change the shape of the transition by dragging the anchor point at the center of the transition. You can move the location of the transition label by clicking the label and dragging it to the new location. Tip When drawing a transition, click once on the state diagram to set the anchor point for the transition. The anchor point allows you to draw an arc instead of a straight line to represent the transition. 14. Double-click the transition to launch the Edit Transition dialog box. 15. In the Transition Name control, enter Wrong # Pins, and click OK. 16. Create a transition from the Check Pin Gap state that loops back to the Check Pin Gap state named Repeat for Next Pin. 17. Create a transition named Failed between the Check Pin Gap and Fail Inspection states. 7-4 ni.com

86 NI Vision Builder for Automated Inspection Tutorial The state diagram should now resemble the state diagram shown in Figure 7-5. Figure 7-5. Completed State Diagram for the Inspection Creating a Variable Since the same inspection needs to be performed on each set of pins, creating a loop in the inspection eliminates the need to configure separate steps to inspect each set of pins. Use the Variable Manager to configure a variable to keep track of the number of times the loop executes. 1. Select Tools»Variable Manager to launch the Variable Manager. 2. On the Inspection Variables tab of the Variable Manager, click Add to launch the Add Inspection Variable dialog box. 3. In the Name control, enter Counter. 4. In the Type control, select Numeric. 5. In the Initial Value control, enter Click OK to create the variable. 7. Click OK to close the Variable Manager. National Instruments 7-5

87 Chapter 7 Looping and Variables Acquiring Inspection Images For simplicity, this tutorial instructs you to use the Simulate Acquisition step. However, in your real-world inspection, use one of the other image acquisition steps to acquire images of the object under inspection. Complete the following instructions to configure a Simulate Acquisition step that simulates acquiring images of the pins on electronic components. 1. On the state diagram, select the Acquire Image & Find Pin Edges state. 2. In the Inspection Steps palette, select the Acquire Images tab. 3. Click the Simulate Acquisition step. The property page for the step opens. Note When the property page for an inspection step opens, if the state diagram is displayed in the Main window, the state diagram switches from the Main window to the Overview window to allow you to use the current inspection image to configure the step. 4. In the Step Name control, enter Acquire Pins. 5. Click the Browse button. The Select an Image File dialog box opens. 6. Navigate to <Vision Builder AI>\DemoImg\Tutorial 6, where <Vision Builder AI> is the location where Vision Builder AI is installed. 7. Select image 01.jpg, and click Open. 8. Make sure the Cycle Through Folder Images control is enabled so that Vision Builder AI loads a different simulation image from the folder each time the step is run. 9. Click OK to add the step to the inspection. 7-6 ni.com

88 NI Vision Builder for Automated Inspection Tutorial Finding Pin Edges Complete the following instructions to configure a Find Edges step to find the edges of the pins and determine if the microchip has the correct number of pins. 1. In the Inspection Steps palette, select the Locate Features tab. 2. Click the Find Edges step. The property page for the step opens. 3. In the Step Name control, enter Find Pin Edges. 4. Hold down the <Shift> key and draw a line from left to right across the width of the image where the pins are located, as shown in Figure 7-6. Figure 7-6. Locating the Edges of the Pins of a Microchip 5. In the Look for control, select All Edges. 6. In the Edge Polarity control, select Bright to Dark Only. 7. On the Limits tab, enable the Minimum Number of Edges control and set the value to Enable the Maximum Number of Edges control and set the value to Click OK to add the step to the inspection. National Instruments 7-7

89 Chapter 7 Looping and Variables Initializing the Variable Use the Set Variable step to set the value of user-defined variables. Complete the following instructions to configure a Set Variable step to initialize the Counter variable. 1. In the Inspection Steps palette, select the Use Additional Tools tab. 2. Click the Set Variable step. The property page for the step opens in the Main window. 3. In the Step Name control, enter Initialize Counter. 4. In the Operation control, select the Set to Constant option and enter 1 for the value. 5. Click OK to add the step to the inspection. Indexing Measurements in a Result Array Complete the following instructions to configure an Array Operator step to index the x and y position results for the ith edge, where i is the value of the Counter variable. The position results are returned by the Find Pin Edges step in the Acquire Image & Find Pin Edges state. 1. In the Overview window, click the Check Pin Gap state on the state diagram. 2. In the Inspection Steps palette, select the Use Additional Tools tab. 3. Click the Array Operator step. The property page for the step opens. 4. In the Step Name control, enter Get Edge Position. 5. In the Array Function list, select Index. 6. In the Source Array control, select the following array elements: Acquire Image & Find Pin Edges»Find Pin Edges»Edge [].X Position Acquire Image & Find Pin Edges»Find Pin Edges»Edge [].Y Position 7. In the Element Index list, select Inspection Variable - Counter. 8. Click OK to add the step to the inspection. 7-8 ni.com

90 NI Vision Builder for Automated Inspection Tutorial In the Updating the Variable section of this tutorial, you will set the Counter variable to increment by one each time the Check Pin Gap state is run. This ensures that a different set of pins is inspected each time the Array Operator step is run. Setting a Coordinate System Complete the following instructions to configure a Set Coordinate System step based on the Find Pin Edges step you configured. 1. In the Inspection Steps palette, select the Locate Features tab. 2. Click the Set Coordinate System step. The property page for the step opens. 3. On the Settings tab, in the Mode control, select Horizontal Motion because the pins may shift horizontally from one image to another. 4. Click OK to add the step to the inspection. Checking the Pin Gap Complete the following instructions to measure the gap between two pins and determine if it is within a certain range. 1. In the Inspection Steps palette, select the Measure Features tab. 2. Click the Caliper step. The property page for the step opens. 3. In the Step Name control, enter Measure Gap. 4. Enable the Reposition Region of Interest control and verify that Set Coordinate System is selected for the Reference Coordinate System control. National Instruments 7-9

91 Chapter 7 Looping and Variables 5. Draw an ROI over the gap between the first two pins, as shown in Figure 7-7. Figure 7-7. Measuring the Distance Between Pins 6. In the Settings tab, select the Process named Horizontal Max Caliper to change the direction and orientation of the caliper search lines. 7. On the Limits tab, enable the Minimum Distance control and set the value to Enable the Maximum Distance control and set the value to Click OK to add the step to the inspection. Updating the Variable After you have measured the gap between two pins, you must increment the Counter variable so that the next time the state is executed the next set of pins is inspected. Complete the following instructions to use a Set Variable step to increment the value of the Counter variable. 1. In the Inspection Steps palette, select the Use Additional Tools tab. 2. Click the Set Variable step. The property page for the step opens in the Main window. 3. In the Step Name control, enter Update Counter ni.com

NI Requirements Gateway

NI Requirements Gateway NI Requirements Gateway Getting Started with NI Requirements Gateway Getting Started with NI Requirements Gateway March 2018 375035C-01 Worldwide Technical Support and Product Information ni.com Worldwide

More information

NI Vision. NI Vision Builder for Automated Inspection Development Toolkit Tutorial. NI Vision Builder for AI Development Toolkit Tutorial

NI Vision. NI Vision Builder for Automated Inspection Development Toolkit Tutorial. NI Vision Builder for AI Development Toolkit Tutorial NI Vision NI Vision Builder for Automated Inspection Development Toolkit Tutorial NI Vision Builder for AI Development Toolkit Tutorial July2018 371424R-01 Support Worldwide Technical Support and Product

More information

NI DIAdemTM. Data Acquisition and Visualization. NI DIAdem: Data Acquisition and Visualization. July E-01

NI DIAdemTM. Data Acquisition and Visualization. NI DIAdem: Data Acquisition and Visualization. July E-01 NI DIAdemTM Data Acquisition and Visualization NI DIAdem: Data Acquisition and Visualization July 2014 374987E-01 Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit ni.com/niglobal

More information

NI Vision. NI Vision Assistant Tutorial. NI Vision Assistant Tutorial. June M

NI Vision. NI Vision Assistant Tutorial. NI Vision Assistant Tutorial. June M NI Vision NI Vision Assistant Tutorial NI Vision Assistant Tutorial June 2011 372228M Support Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit ni.com/niglobal to access

More information

NI DIAdem. Getting Started with DIAdem. Getting Started with NI DIAdem. July M-01

NI DIAdem. Getting Started with DIAdem. Getting Started with NI DIAdem. July M-01 TM NI DIAdem Getting Started with DIAdem Getting Started with NI DIAdem July 2014 373422M-01 Support Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit ni.com/niglobal to

More information

NI DataFinder Server Edition

NI DataFinder Server Edition NI DataFinder Server Edition Search Engine for Technical Data NI DataFinder Server Edition July 2015 374430K Support Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit ni.com/niglobal

More information

NI crio Module Development Kit User Manual. CompactRIO. Software User Manual. CompactRIO Module Development Kit Software Manual

NI crio Module Development Kit User Manual. CompactRIO. Software User Manual. CompactRIO Module Development Kit Software Manual NI crio-9951 TM CompactRIO Software User Manual Module Development Kit User Manual CompactRIO Module Development Kit Software Manual November 2017 375951B-01 Support Worldwide Technical Support and Product

More information

NI Picture Quality Analysis

NI Picture Quality Analysis NI Picture Quality Analysis NI Picture Quality Analysis Getting Started Guide NI Picture Quality Analysis Getting Started Guide July 2014 375771B-01 Support Worldwide Technical Support and Product Information

More information

NI DIAdem. Getting Started with DIAdem. Getting Started with DIAdem. May P-01

NI DIAdem. Getting Started with DIAdem. Getting Started with DIAdem. May P-01 TM NI DIAdem Getting Started with DIAdem Getting Started with DIAdem May 2017 373422P-01 Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit ni.com/niglobal to access the

More information

LabVIEW DataFinder Toolkit

LabVIEW DataFinder Toolkit LabVIEW DataFinder Toolkit LabVIEW DataFinder Toolkit June 2009 375141A-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac

More information

FOUNDATION. Fieldbus. NI-FBUS Hardware and Software User Manual. NI-FBUS Hardware and Software User Manual. January H-01

FOUNDATION. Fieldbus. NI-FBUS Hardware and Software User Manual. NI-FBUS Hardware and Software User Manual. January H-01 TM FOUNDATION Fieldbus NI-FBUS Hardware and Software User Manual NI-FBUS Hardware and Software User Manual January 2014 371994H-01 Support Worldwide Technical Support and Product Information ni.com Worldwide

More information

NI OCR Training Interface Help

NI OCR Training Interface Help NI OCR Training Interface Help August 2008, 370643G-01 The NI OCR Training Interface Help contains information about how to use the OCR Training Interface to train characters, save character sets, and

More information

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A 3-4 SAS/SATA II HDD Canister Entry version XC-34D1-SA10-0-R USER S MANUAL Document number: MAN-00077-A ii Preface Important Information Warranty Our product is warranted against defects in materials and

More information

LabWindowsTM /CVITM. Getting Started with LabWindows/CVI. Getting Started with LabWindows/CVI. August J-01

LabWindowsTM /CVITM. Getting Started with LabWindows/CVI. Getting Started with LabWindows/CVI. August J-01 LabWindowsTM /CVITM Getting Started with LabWindows/CVI Getting Started with LabWindows/CVI August 2013 373552J-01 Support Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit

More information

Bracket and Mounting Dimensions

Bracket and Mounting Dimensions INSTALLATION GUIDE NI PS-14/15/16/17 Panel Mount Brackets This document provides the installation procedure for the NI PS-14/15/16/17 Panel Mount Brackets. Use accessory 199432-01 to mount NI PS-14/15/16/17

More information

NI WSN-9791 Ethernet Gateway

NI WSN-9791 Ethernet Gateway GETTING STARTED GUIDE NI WSN-9791 Ethernet Gateway This guide describes how to install, configure, and verify the National Instruments Wireless Sensor Network (WSN) 9791 gateway, NI WSN nodes, and NI software.

More information

VI Logger. Getting Started with VI Logger. Getting Started with VI Logger. May 2003 Edition Part Number B-01

VI Logger. Getting Started with VI Logger. Getting Started with VI Logger. May 2003 Edition Part Number B-01 VI Logger Getting Started with VI Logger Getting Started with VI Logger May 2003 Edition Part Number 322821B-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate

More information

NI DIAdemTM. Data Acquisition and Visualization. NI DIAdem: Data Acquisition and Visualization. May F-01

NI DIAdemTM. Data Acquisition and Visualization. NI DIAdem: Data Acquisition and Visualization. May F-01 NI DIAdemTM Data Acquisition and Visualization NI DIAdem: Data Acquisition and Visualization May 2017 374987F-01 Support Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

GETTING STARTED GUIDE

GETTING STARTED GUIDE GETTING STARTED GUIDE NI 9795 WSN C Series Gateway This guide describes how to install, configure, and verify the National Instruments 9795 Wireless Sensor Network (WSN) C Series gateway, NI WSN nodes,

More information

NI SignalExpressTM. Getting Started with NI SignalExpress Tektronix Edition. June B-01

NI SignalExpressTM. Getting Started with NI SignalExpress Tektronix Edition. June B-01 NI SignalExpressTM Getting Started with NI SignalExpress Tektronix Edition Getting Started with NI SignalExpress Tektronix Edition June 2006 374297B-01 Support Worldwide Technical Support and Product Information

More information

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral GETTING STARTED GUIDE NI USRP-2900/2901 Universal Software Radio Peripheral This document explains how to install, configure, and test your NI universal software radio peripheral (USRP) 2900 or 2901 (NI

More information

Electromagnetic Compatibility Guidelines

Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE Power Amplifier Français Deutsch ni.com/manuals This document explains how to install, configure, and set up the power amplifier. NI-DAQmx 9.8 has added support for the device. To

More information

NI Circuit Design Suite

NI Circuit Design Suite NI Circuit Design Suite Getting Started with NI Circuit Design Suite Getting Started with NI Circuit Design Suite July 2013 374482G Worldwide Technical Support and Product Information ni.com Worldwide

More information

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE NI USB-7845R R Series for USB Multifunction RIO with Kintex-7 70T FPGA Français Deutsch 日本語한국어简体中文 ni.com/manuals This document explains how to install and configure National Instruments

More information

NI Vision. NI CVS-1457RT User Manual. GigE Vision Compact Vision System. NI CVS-1457RT User Manual. October A-01

NI Vision. NI CVS-1457RT User Manual. GigE Vision Compact Vision System. NI CVS-1457RT User Manual. October A-01 NI Vision NI CVS-1457RT User Manual GigE Vision Compact Vision System NI CVS-1457RT User Manual October 2013 374217A-01 Support Worldwide Technical Support and Product Information ni.com Worldwide Offices

More information

LabWindows /CVI Version 2017

LabWindows /CVI Version 2017 RELEASE NOTES LabWindows /CVI Version 2017 These release notes introduce LabWindows /CVI 2017. Refer to this document for system requirements, installation and activation instructions, and information

More information

Foundation Fieldbus Hardware and NI-FBUS Software

Foundation Fieldbus Hardware and NI-FBUS Software INSTALLATION GUIDE Foundation Fieldbus Hardware and NI-FBUS Software This guide contains installation and configuration instructions for the PCI-FBUS, PCMCIA-FBUS, and USB-8486. Note Install the NI-FBUS

More information

Installation Operation & Specifications Manual. General Description

Installation Operation & Specifications Manual. General Description 101-0020 USB to 2-Wire RS-485 Converter Installation Operation & Specifications Manual General Description The 101-0020 USB to RS-485 converter provides a simple, low cost interface between a PC or laptop

More information

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R. GETTING STARTED GUIDE NI PCIe-7821R R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA This document describes how to begin using the PCIe-7821R. Safety Guidelines Caution

More information

LabVIEW FPGA Module Version 2013

LabVIEW FPGA Module Version 2013 RELEASE AND UPGRADE NOTES LabVIEW FPGA Module Version 2013 This document contains instructions for installing the LabVIEW 2013 FPGA Module and related products, introduces new features, and provides information

More information

ETConcept Systems Engineering. User s Guide

ETConcept Systems Engineering. User s Guide Wiegand to RS485 Converter User s Guide Nov-08 Copyright 2008. All rights reserved including the right of reproduction in whole or in part in any form. Contents List of Accessories Included... 1 List

More information

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module CALIBRATION PROCEDURE NI 9216/9226 8-Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module This document contains the verification and adjustment procedures for the National Instruments 9216 and National

More information

LabVIEW TM Real-Time 2: Architecting Embedded Systems Exercises

LabVIEW TM Real-Time 2: Architecting Embedded Systems Exercises LabVIEW TM Real-Time 2: Architecting Embedded Systems Exercises Course Software Version 2012 November 2012 Edition Part Number 325585B-01 LabVIEW Real-Time 2 Exercises Copyright 2010 2012 National Instruments

More information

NOTE TO USERS NI 61xx Pinout Labels for the SCB-68 Multifunction I/O S Series Modules/Devices Using the 68-Pin Shielded Connector Block

NOTE TO USERS NI 61xx Pinout Labels for the SCB-68 Multifunction I/O S Series Modules/Devices Using the 68-Pin Shielded Connector Block NOTE TO USERS NI xx Pinout Labels for the SCB- Multifunction I/O S Series Modules/Devices Using the -Pin Shielded Connector Block If you are using an NI xx (formerly referred to as S Series) multifunction

More information

NI PCIe NI PCIe-6509 Register Level Programming Reference Manual. NI PCIe-6509 Reference Manual. January A-01

NI PCIe NI PCIe-6509 Register Level Programming Reference Manual. NI PCIe-6509 Reference Manual. January A-01 NI PCIe-6509 NI PCIe-6509 Register Level Programming Reference Manual NI PCIe-6509 Reference Manual January 2012 373665A-01 Support Worldwide Technical Support and Product Information ni.com Worldwide

More information

24-Channel, ±24 V Precision PXI Source Measure Unit

24-Channel, ±24 V Precision PXI Source Measure Unit GETTING STARTED GUIDE PXIe-4163 24-Channel, ±24 V Precision PXI Source Measure Unit This document explains how to install, configure, and test the PXIe-4163. The PXIe-4163 ships with NI-DCPower driver

More information

NI SMD-7610 Stepper Drives and NI 9512 C Series Modules

NI SMD-7610 Stepper Drives and NI 9512 C Series Modules GETTING STARTED NI SMD-7610 Stepper Drives and NI 9512 C Series Modules This document explains how to install and configure the NI SMD-7610 stepper drives for use with the NI 9512 C Series drive interface

More information

National Instruments PCI-7340 Manual Get Pricing & Availability at ApexWaves.com. Call Today:

National Instruments PCI-7340 Manual Get Pricing & Availability at ApexWaves.com. Call Today: National Instruments PCI-7340 Manual Get Pricing & Availability at ApexWaves.com Call Today: 1-800-915-6216 Email: sales@apexwaves.com https://www.apexwaves.com/modular-systems/national-instruments/pci-controllers/pci-7340

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment. Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment. FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS

More information

NI ELVIS RIO Control Module

NI ELVIS RIO Control Module USER MANUAL NI ELVIS RIO Control Module The NI ELVIS RIO Control Module is a reconfigurable I/O (RIO) device that is used to design control, robotics, and mechatronics systems. This document contains pinouts,

More information

NI-488.2TM. NI User Manual. NI User Manual. June W-01

NI-488.2TM. NI User Manual. NI User Manual. June W-01 NI-488.2TM NI-488.2 User Manual NI-488.2 User Manual June 2018 370428W-01 Support Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit ni.com/niglobal to access the branch

More information

LabWindowsTM /CVITM. Getting Started with LabWindows/CVI. Getting Started with LabWindows/CVI. August K-01

LabWindowsTM /CVITM. Getting Started with LabWindows/CVI. Getting Started with LabWindows/CVI. August K-01 LabWindowsTM /CVITM Getting Started with LabWindows/CVI Getting Started with LabWindows/CVI August 2015 373552K-01 Support Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit

More information

Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product.

Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product. GETTING STARTED GUIDE NI Switches SCXI Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. Your NI SCXI switch module ships with the NI-SWITCH

More information

System Overview and Terms

System Overview and Terms GETTING STARTED GUIDE NI Condition Monitoring Devices and NI InsightCM Server Version 3.0 This document contains step-by-step instructions for the setup tasks you must complete to connect an NI Condition

More information

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA GETTING STARTED GUIDE NI PXIe-7867R R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA This document describes how to begin

More information

LabVIEW. Getting Started with LabVIEW. Getting Started with LabVIEW

LabVIEW. Getting Started with LabVIEW. Getting Started with LabVIEW Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100 Worldwide Offices

More information

NI TestStand ATML Toolkit

NI TestStand ATML Toolkit RELEASE NOTES NI ATML Toolkit Version 2012 Contents Getting Started New Users These release notes contain NI ATML Toolkit 2012 system requirements, installation instructions, information about new features,

More information

NI Vision. NI CVS-1458RT User Manual. Compact Vision System with GigE Vision and Reconfigurable I/O. NI CVS-1458RT User Manual

NI Vision. NI CVS-1458RT User Manual. Compact Vision System with GigE Vision and Reconfigurable I/O. NI CVS-1458RT User Manual NI Vision NI CVS-1458RT User Manual Compact Vision System with GigE Vision and Reconfigurable I/O NI CVS-1458RT User Manual November 2014 374866A-01 Support Worldwide Technical Support and Product Information

More information

LabVIEW DataFinder Toolkit

LabVIEW DataFinder Toolkit LabVIEW DataFinder Toolkit Use the NI LabVIEW DataFinder Toolkit to work with the DataFinder in LabVIEW. You can use the DataFinder to search for simple texts or to execute extended queries for specific

More information

NI TestStandTM. Using LabVIEW. with TestStand. Using LabVIEW with TestStand. April B-01

NI TestStandTM. Using LabVIEW. with TestStand. Using LabVIEW with TestStand. April B-01 NI TestStandTM TM Using LabVIEW with TestStand Using LabVIEW with TestStand April 2007 373200B-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters

More information

DIAdem TM Basics Course Manual

DIAdem TM Basics Course Manual DIAdem TM Basics Course Manual Course Software Version 2012 January 2013 Edition Part Number 325989K-01 DIAdem Basics Copyright 1995 2013 National Instruments Ireland Resources Limited. All rights reserved.

More information

NI TestStand ATML Toolkit Version 2013

NI TestStand ATML Toolkit Version 2013 RELEASE NOTES NI ATML Toolkit Version 2013 These release notes contain NI ATML Toolkit 2013 system requirements, installation instructions, information about new features, and other changes since the ATML

More information

GETTING STARTED NI 9501 C Series Stepper Drive Modules and NI SoftMotion Module

GETTING STARTED NI 9501 C Series Stepper Drive Modules and NI SoftMotion Module GETTING STARTED NI 9501 C Series Stepper Drive Modules and NI SoftMotion Module Note If you are a new user of LabVIEW or are unfamiliar with LabVIEW, refer to the Getting Started with LabVIEW manual for

More information

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch USER MANUAL Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) This document describes the features of the and contains information about mounting and operating the device. Upstream Connection

More information

INSTALLATION INSTRUCTIONS Data Management Software Suite in the Evaluation Mode

INSTALLATION INSTRUCTIONS Data Management Software Suite in the Evaluation Mode INSTALLATION INSTRUCTIONS Data Management Software Suite in the Evaluation Mode Overview Here are instructions for installing and configuring the Data Management Software Suite, which includes DataFinder

More information

MicroLink Installation Operation & Specifications Manual. General Description

MicroLink Installation Operation & Specifications Manual. General Description TM MicroLink HART Protocol Modem - USB Interface 101-0007 Installation Operation & Specifications Manual General Description The MicroLink 101-0007 is a USB to HART device Interface. It provides the hardware

More information

CALIBRATION PROCEDURE PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

CALIBRATION PROCEDURE PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals CALIBRATION PROCEDURE PXIe-4310 8-channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module Français Deutsch ni.com/manuals This document contains the verification and adjustment procedures for

More information

12-Channel, ±24 V Precision PXI Source Measure Unit

12-Channel, ±24 V Precision PXI Source Measure Unit GETTING STARTED GUIDE PXIe-4162 12-Channel, ±24 V Precision PXI Source Measure Unit This document explains how to install, configure, and test the PXIe-4162. The PXIe-4162 ships with NI-DCPower driver

More information

Contents. Getting Started. RELEASE NOTES TestStand ATML Toolkit Version 2017

Contents. Getting Started. RELEASE NOTES TestStand ATML Toolkit Version 2017 RELEASE NOTES TestStand ATML Toolkit Version 2017 These release notes contain TestStand ATML Toolkit 2017 system requirements, installation instructions, information about new features, and other changes

More information

CALIBRATION PROCEDURE NI channel, ±2- ma/±10 V, 24-bit Analog Input Module. ni.com/manuals

CALIBRATION PROCEDURE NI channel, ±2- ma/±10 V, 24-bit Analog Input Module. ni.com/manuals CALIBRATION PROCEDURE NI 9207 16-channel, ±2- ma/±10 V, 24-bit Analog Input Module Français Deutsch ni.com/manuals This document contains the verification and adjustment procedures for the National Instruments

More information

Electronics WorkbenchTM

Electronics WorkbenchTM Electronics WorkbenchTM MultiVHDL 8 Programmable Logic User Guide TitleShort-Hidden (cross reference text) February 2006 371888A-01 Support Worldwide Technical Support and Product Information ni.com National

More information

DIAdemTM. Data Acquisition and Visualization. NI DIAdem: Data Acquisition and Visualization. July C-01

DIAdemTM. Data Acquisition and Visualization. NI DIAdem: Data Acquisition and Visualization. July C-01 DIAdemTM Data Acquisition and Visualization NI DIAdem: Data Acquisition and Visualization July 2012 374987C-01 Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit ni.com/niglobal

More information

TestStand. Using LabWindows /CVI with TestStand. Using LabWindows/CVI with TestStand. July 2003 Edition Part Number A-01

TestStand. Using LabWindows /CVI with TestStand. Using LabWindows/CVI with TestStand. July 2003 Edition Part Number A-01 TM TestStand TM Using LabWindows /CVI with TestStand TM Using LabWindows/CVI with TestStand July 2003 Edition Part Number 323201A-01 Support Worldwide Technical Support and Product Information ni.com National

More information

LabVIEW VI Analyzer Toolkit

LabVIEW VI Analyzer Toolkit USER GUIDE LabVIEW VI Analyzer Toolkit The LabVIEW VI Analyzer Toolkit allows you to interactively and programmatically test VIs to find areas for improvement. The toolkit contains tests that address a

More information

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R. GETTING STARTED GUIDE NI PXIe-7822R R Series for PXI Express Digital RIO with Kintex-7 325T FPGA Français Deutsch 日本語한국어简体中文 ni.com/manuals This document explains how to install and configure the NI PXIe-7822R.

More information

NI CVS Required Components. Optional Equipment GETTING STARTED GUIDE. Compact Vision System with USB3 Vision and Reconfigurable I/O

NI CVS Required Components. Optional Equipment GETTING STARTED GUIDE. Compact Vision System with USB3 Vision and Reconfigurable I/O GETTING STARTED GUIDE NI CVS-1459 Compact Vision System with USB3 Vision and Reconfigurable I/O The NI CVS-1459 is a compact vision system that acquires, processes, and displays images from USB3 Vision

More information

NI-488.2TM. NI User Manual. NI User Manual. January N-01

NI-488.2TM. NI User Manual. NI User Manual. January N-01 NI-488.2TM NI-488.2 User Manual NI-488.2 User Manual January 2013 370428N-01 Support Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit ni.com/niglobal to access the branch

More information

RMX. RMX Programmable Power Supplies User Manual RMX-4120 RMX-4121 RMX-4122 RMX-4123 RMX-4124 RMX-4125 RMX-4126 RMX February C-01

RMX. RMX Programmable Power Supplies User Manual RMX-4120 RMX-4121 RMX-4122 RMX-4123 RMX-4124 RMX-4125 RMX-4126 RMX February C-01 RMX RMX Programmable Power Supplies User Manual RMX-4120 RMX-4121 RMX-4122 RMX-4123 RMX-4124 RMX-4125 RMX-4126 RMX-4127 RMX Programmable Power Supplies User Manual February 2017 375744C-01 About the RMX

More information

Contents. Software. CALIBRATION PROCEDURE NI Channel, 300 Vrms, 24-Bit, Simultaneous, Channel-to-Channel Isolated Analog Input Module

Contents. Software. CALIBRATION PROCEDURE NI Channel, 300 Vrms, 24-Bit, Simultaneous, Channel-to-Channel Isolated Analog Input Module CALIBRATION PROCEDURE NI 9225 3-Channel, 300 Vrms, 24-Bit, Simultaneous, Channel-to-Channel Isolated Analog Input Module Français Deutsch ni.com/manuals This document contains the verification and adjustment

More information

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals USER MANUAL R Series for USB Multifunction RIO with Kintex-7 70T FPGA Français Deutsch 日本語한국어简体中文 ni.com/manuals This document provides dimensions, connectivity information, and pinouts for the National

More information

InLinK HM Setup Software Installation & Operation Manual

InLinK HM Setup Software Installation & Operation Manual InLinK HM HART Protocol Modem Module with HART Device to Modbus Accumulator for OEM Applications 101-0014 Setup Software Installation & Operation Manual InLink-HM 101-0014 is a complete OEM HART protocol

More information

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals USER MANUAL NI USB-7856R OEM R Series for USB Multifunction RIO with Kintex-7 160T FPGA Français Deutsch 日本語한국어简体中文 ni.com/manuals This document provides dimensions, connectivity information, and pinouts

More information

±10 V, 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module

±10 V, 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module CALIBRATION PROCEDURE NI 9775 ±10 V, 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module This document contains the verification and adjustment procedures for the NI 9775. For more information on calibration,

More information

Contents. Software. CALIBRATION PROCEDURE NI Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module

Contents. Software. CALIBRATION PROCEDURE NI Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module CALIBRATION PROCEDURE NI 9234 4-Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module This document contains the verification and adjustment procedures for the National Instruments

More information

NI R Series. Contents. Software CALIBRATION PROCEDURE

NI R Series. Contents. Software CALIBRATION PROCEDURE CALIBRATION PROCEDURE NI R Series NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, and NI USB-785xR This document contains the verification and adjustment

More information

LabWindows /CVI Version 2015

LabWindows /CVI Version 2015 RELEASE NOTES LabWindows /CVI Version 2015 These release notes introduce LabWindows /CVI 2015. Refer to this document for system requirements, installation and activation instructions, and information

More information

INSTALLATION INSTRUCTIONS Data Management Software Suite

INSTALLATION INSTRUCTIONS Data Management Software Suite INSTALLATION INSTRUCTIONS Data Management Software Suite Contents Overview... 1 Installing the NI Volume License Manager... 2 Installing TDM Server... 3 Set Up NI Volume License Manager... 18 Register

More information

GETTING STARTED NI SMD-7611/7612 Stepper Drives and NI 9512 C Series Modules

GETTING STARTED NI SMD-7611/7612 Stepper Drives and NI 9512 C Series Modules GETTING STARTED NI SMD-7611/7612 Stepper Drives and NI 9512 C Series Modules Note If you are a new user of LabVIEW or are unfamiliar with LabVIEW, refer to the Getting Started with LabVIEW manual for information

More information

Using Your NI Software for DOS or Windows 3 with Windows 95/98

Using Your NI Software for DOS or Windows 3 with Windows 95/98 Using Your NI-488.2 Software for DOS or Windows 3 with Windows 95/98 Using NI-488.2 with Windows 95/98 June 1998 Edition Part Number 321011C-01 Copyright 1995, 1998 National Instruments Corporation. All

More information

NI USB Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10 MHz to 18 GHz RF Power Meter

NI USB Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10 MHz to 18 GHz RF Power Meter GETTING STARTED GUIDE NI USB-5684 10 MHz to 18 GHz RF Power Meter This document explains how to install, configure, and set up the NI USB-5684 radio frequency (RF) power meter. NI RF power meters make

More information

NI DataSocket Server Help

NI DataSocket Server Help NI DataSocket Server Help April 2003 Edition, Part Number 370716A-01 Use this help file as a reference for information about the DataSocket Server, DataSocket Server Manager, DataSocket Server Diagnostics

More information

NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, NI USB-785xR, and NI PXIe-786xR

NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, NI USB-785xR, and NI PXIe-786xR CALIBRATION PROCEDURE NI R Series NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, NI USB-785xR, and NI PXIe-786xR This document contains the verification

More information

Getting Started with the LabVIEW Robotics Module Version 2011

Getting Started with the LabVIEW Robotics Module Version 2011 Getting Started with the LabVIEW Robotics Module Version 2011 Contents The LabVIEW Robotics Module is a software package that allows you to develop and deploy a robotics application using LabVIEW, other

More information

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION NI cdaq -9136 NI CompactDAQ Four-Slot Controller with Quad-Core Processor This document includes compliance precautions and connection information for

More information

SCXI -1102/B/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

SCXI -1102/B/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx CALIBRATION PROCEDURE SCXI -1102/B/C For NI-DAQmx Contents This document contains information and instructions for calibrating the National Instruments SCXI-1102/B/C signal conditioning module. Conventions...

More information

NI DIAdemTM. Data Mining, Analysis, and Report Generation. NI DIAdem: Data Mining, Analysis, and Report Generation. July K-01

NI DIAdemTM. Data Mining, Analysis, and Report Generation. NI DIAdem: Data Mining, Analysis, and Report Generation. July K-01 NI DIAdemTM Data Mining, Analysis, and Report Generation NI DIAdem: Data Mining, Analysis, and Report Generation July 2012 323082K-01 Worldwide Technical Support and Product Information ni.com Worldwide

More information

PXI. NI PXI-665x User Manual. Timing and Synchronization Module for PXI. NI PXI-665x User Manual. May C-01

PXI. NI PXI-665x User Manual. Timing and Synchronization Module for PXI. NI PXI-665x User Manual. May C-01 PXI NI PXI-665x User Manual Timing and Synchronization Module for PXI NI PXI-665x User Manual May 2015 370711C-01 Support Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit

More information

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627.

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627. GETTING STARTED GUIDE NI sbrio-9627 Single-Board RIO OEM Devices This document describes how to begin using the NI sbrio-9627. Safety Guidelines Operate the sbrio-9627 only as described in the user documentation.

More information

NI Vision. NI CVS-1458 User Manual. Compact Vision System with GigE Vision and Reconfigurable I/O. NI CVS-1458 User Manual. August A-01

NI Vision. NI CVS-1458 User Manual. Compact Vision System with GigE Vision and Reconfigurable I/O. NI CVS-1458 User Manual. August A-01 NI Vision NI CVS-1458 User Manual Compact Vision System with GigE Vision and Reconfigurable I/O NI CVS-1458 User Manual August 2015 375272A-01 Support Worldwide Technical Support and Product Information

More information

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous GETTING STARTED GUIDE NI 9266 8 AO, 0 ma to 20 ma, 16 Bit Simultaneous This document explains how to connect to the NI 9266. In this document, the NI 9266 with screw terminal and the NI 9266 with DSUB

More information

SCXI -1104/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

SCXI -1104/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx CALIBRATION PROCEDURE SCXI -1104/C For NI-DAQmx Contents This document contains information and instructions for calibrating the National Instruments SCXI-1104/C signal conditioning module. Conventions...

More information

NI PCIe Hardware Overview. Functional Overview USER MANUAL. Base, Medium, Full, and Extended Configuration Camera Link Frame Grabber

NI PCIe Hardware Overview. Functional Overview USER MANUAL. Base, Medium, Full, and Extended Configuration Camera Link Frame Grabber USER MANUAL NI PCIe-1477 Base, Medium, Full, and Extended Configuration Camera Link Frame Grabber The NI PCIe-1477 is an image acquisition device with a PCIe 2.0 x8 host interface. It has a user-configurable

More information

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module GETTING STARTED GUIDE NI 9475 8-Channel, 60 V, High-Speed, Sourcing Digital Output Module This document explains how to connect to the NI 9475. Note Before you begin, complete the software and hardware

More information

NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU GETTING STARTED GUIDE NI PXIe-4138/4139 Single-Channel System SMU Note Before you begin, install and configure your chassis and controller. This document explains how to install, configure, and test the

More information

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module GETTING STARTED GUIDE NI 9425 24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module This document explains how to connect to the NI 9425. In this document, the NI 9425 with spring terminal and

More information

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module GETTING STARTED GUIDE NI 9247 3-Channel, 50 Arms Continuous, 24-Bit, Analog Input Module This document explains how to connect to the NI 9247. Note Before you begin, complete the software and hardware

More information

Getting Started With Visionscape Smart Camera HE1600T v3.7.3, Mar 2009

Getting Started With Visionscape Smart Camera HE1600T v3.7.3, Mar 2009 Getting Started With Visionscape Smart Camera HE1600T v3.7.3, Mar 2009 EM-40265-1V373 Copyright and Disclaimer Copyright 2009 by Microscan Systems, Inc. 1201 S.W. 7th Street, Renton, WA, U.S.A. 98057 (425)

More information

PXIe Contents. Verifying the System Requirements GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

PXIe Contents. Verifying the System Requirements GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument GETTING STARTED GUIDE PXIe-6571 32-Channel Digital Pattern Instrument Note Before you begin, install and configure your chassis and controller. This document explains how to install, configure, and test

More information

IMAGE STUDIO LITE. Tutorial Guide Featuring Image Studio Analysis Software Version 3.1

IMAGE STUDIO LITE. Tutorial Guide Featuring Image Studio Analysis Software Version 3.1 IMAGE STUDIO LITE Tutorial Guide Featuring Image Studio Analysis Software Version 3.1 Notice The information contained in this document is subject to change without notice. LI-COR MAKES NO WARRANTY OF

More information