1 SOLUTIONS FOR IES/LDT FILE CREATION Presented By Austin Piehl June 20, Radiant Vision Systems, LLC. All Rights Reserved.
2 Light & Color Automated Visual Inspection Global Support
3 TODAY S AGENDA Solutions for IES/LDT File Creation: Conventional Goniophotometry The Near-Field Measurement System The Measurement Process Types of Data Acquired: Near-field data Far-field data Software Demo Working with Radiant PM-NFMS Software How to export IES/LDT files from measured data Comments on the LM-79 Method 3
4 IES/LDT FILE CREATION FOR LIGHT SOURCE CHARACTERIZATION 4
5 PHOTOMETRIC DATA FILES ASCII (delimited text) file containing luminous intensity data for a light source Used to observe total light output and angular spread of output of a source for lighting design Data can be used to generate polar and cone diagrams in common optical design programs File formats: IES (*.ies) EULUMDAT (*.LDT) Illuminating Engineering Society of North America (IESNA) created standard LM IES Recommended Standard File Format for Electronic Transfer of Photometric Data IES most common photometric file format in North America; EULUMDAT standard in Europe 5
6 PHOTOMETRIC DATA FILES 3D Diagram from IES Data IES Data: Luminous Intensity Distribution 6
7 CREATING IES FILES IES/LDT files are generated using near-field and far-field techniques in the lab Dark room needed for accurate measurement Size of lab space depends on measurement solution Generally two solutions available: Conventional Goniophotometry (Far-Field Measurement System) Near-Field Measurement Systems 7
8 WHAT TYPES OF DATA ARE THERE? NEAR-FIELD LED strip FAR FIELD Near-Field: Analyze millions of points at a time Goniometer + (imaging photometer or- imaging colorimeter) Small space needed for measurements Far-Field: Analyze one point at a time Goniometer + spot meter (spectrometer or photometer) Larger space needed for measurements 8
9 WHAT SOLUTIONS ARE AVAILABLE? Source is mounted on a goniometer and: Is rotated in two axes allowing entire intensity distribution to be sampled, or Conventional Goniophotometry Source is fixed, with a flying mirror directing light to the sensor Stationary spot photometer placed in farfield Luminous intensity distribution created from point measurements Light Source Two-axis goniometer Photodetector or radiometer Near field measurements must be completed using separate instrumentation 9
10 WHAT SOLUTIONS ARE AVAILABLE? Advantages: Accurate Generates IES/Far-field data LM-79 Certified Conventional Goniophotometry Disadvantages: Expensive Requires a very large lab space Increased possibility for stray light No near-field data capability Time-consuming (depends on 3 rd party lab turnaround time) Cost may be reduced by sending luminaires to a testing lab, but this requires weeks to months of turnaround time. 10
11 WHAT SOLUTIONS ARE AVAILABLE? Near-Field Measurement Systems (NFMS) Advantages: Cost Effective Accurate Near- and Far-Field Data Generate IES/LDT Files Minimal lab space (5 to ~20 feet) Time efficient (in-house: hrs/device) Disadvantages: Not LM-79 Certified (discussion to come) 11
12 THE RADIANT SOLUTION: PM-NFMS 12
13 HOW DOES THE NFMS WORK? PM-NFMS: ProMetric Near-Field Measurement System Source is mounted on a two-axis goniometer Stationary imaging colorimeter placed in near-field views source directly Source is rotated in two axes, and luminance is measured at all angles 13
14 NFMS MEASUREMENT THEORY Light source is not treated as a point source Spatial information recorded Luminance and color measurements are recorded at each angle Software produces powerful model of luminance and chromaticity as a function of angle 14
15 WHAT TYPES OF DATA ARE THERE? Far-Field: Luminous Intensity Luminous Flux in a given direction I(q,f) By definition a far-field measurement assumes the source is a point Near-Field: Luminance Luminous flux in a given direction per unit area L(x, y, q, f) By definition a near-field measurement considers the spatial extent of the source More complete than far-field data alone 15
16 SYSTEM REQUIREMENTS AND PERFORMANCE Traditional Far-field System Need for stray light control No ray tracing to far-field Minimal source information Large lab area needed, proportional to source size Near-field System Minimal area required for measurement, no tunnel needed Data can be used in optical ray trace software to accurately describe illuminance distributions at any distance Luminance data obtained (provides unified glare rating measurement) 16
17 WHAT DO WE MEASURE? Near-Field Data More detailed information than far-field only techniques Z Light leaves an extended source not a point source Predicts illumination pattern at any distance from the source X Y Measuring near-field gives near and far-field data. 17
18 NEAR- AND FAR-FIELD DISTRIBUTIONS Frame is designed to hold large or small luminaires Near and far field models can be produced in one scan Near Field (As measured) Far Field (Ray-Traced to infinity) 18
19 RESULTING DATA SETS Luminance Chromaticity (spatially resolved) Luminous Intensity Illuminance at a given distance Near field distribution Far-field distribution (ray-traced) Spectra (with optional SP-1000) 19
20 VIEW ANGLE PERFORMANCE Luminance Intensity Chromaticity Spectrum (requires optional spectrometer) Correlated color temperature (CCT) Color rendering index (requires optional spectrometer) Unified glare rating 20
21 DATA OUTPUT IES, EULUMDAT, and Radiant Source Model output formats Data can easily be imported into various optical modeling software programs 21
22 OPTICAL MODELING SOFTWARE PROGRAMS ASAP FRED LightTools OpticStudio (ZEMAX) Opticad SPEOS TracePro Photopia IES TM-25 22
23 ILLUMINATION DISTRIBUTIONS Simulate illumination at a given distance using the ray sets, accurate in both space and angle Example: Simulate illumination of countertop with under-cabinet lighting Cannot be done with IES/LDT file 23
24 HOW DOES THE NFMS STACK UP? Complete All of the image data can be retained for further analysis Provides extensive data set: Near field/far field Illumination IES EULUMDAT (LDT) Optional spectra Cost-effective Fast results; much less expensive than a flying mirror photogoniometer Can use camera for other measurements (illuminance) Accurate Proven to be within ~1% of reference measurements Intensity (cd) Far-Field Intensity at 3.4m from Source 40,000 30,000 20,000 10,000 0 Spot Goniophotometer Near-field FPMS-LI Goniometer Imaging Colorimeter Angle (degrees) 24
25 APPLICATIONS OF RADIANT S NFMS 25
26 TYPICAL APPLICATIONS View angle performance Optical Modeling: Near- and far-field luminous intensity distribution for large light sources (in compact lab spaces) Illumination distribution measurement for large light sources Illumination modeling of room and architectural lighting systems 26
27 INDOOR/OUTDOOR LIGHTING IES and EULUMDAT (LDT) file export formats 27
28 WHAT ABOUT THE LM-79 METHOD? Source is not aligned as it would be used with respect to gravity Very little difference exists between the output of a lamp aligned in one orientation vs. another Cannot certify, but can create IES/LDT files that are just as accurate NFMS is not intended to be a certification system Value lies in precertification testing Know that you will pass LM-79 before you send out for certification testing Reduces time and cost Generates IES/LDT files needed for all lighting systems Can create ray files, for spatial modeling of light exiting the lamp 28
29 SUMMARY Photometric data files (IES and LDT) offer critical light source measurement data for lighting design, such as luminous intensity, overall output, and angular spread. Two solutions for IES/LDT generation are Conventional Goniophotometers and Near- Field Measurement Systems. Near-Field Measurement Systems have significant advantages over conventional goniophotometers for near- and far-field data acquisition in terms of cost, speed, size, and lab space, and offer equal accuracy. Radiant s PM-NFMS solution consists of an imaging colorimeter, two-axis goniometer, and PM-NFMS Software for generating IES, EULUMDAT, and Radiant Source Model files. PM-NFMS Software creates photometric data files in IES/LDT format, which can be output as polar and cone diagrams using any common optical design program. 29
30 THANK YOU! Questions? Contact 2017 Radiant Vision Systems, LLC. All Rights Reserved.
NEAR FIELD GONIOMETRIC SYSTEMS FOR SOLID STATE LIGHTING: LUMINANCE, INTENSITY, COLOR, AND
NEAR FIELD GONIOMETRIC SYSTEMS FOR SOLID STATE LIGHTING: LUMINANCE, INTENSITY, COLOR, AND SPECTRA AS A FUNCTION OF ANGLE Douglas Kreysar Chief Operating Officer Presentation Outline What is a Near Field
More informationLED19WPAR38/NFL/827-DIM
LED19WPAR38/NFL/827-DIM EiKO Global, LLC Model: LED19WPAR38/NFL/827-DIM TABLE OF CONTENTS 1 - GENERAL INFORMATION... 3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)... 3 1.2 OBJECTIVE... 3 1.3
More informationAccurate LED Source Modeling using TracePro
Accurate LED Source Modeling using TracePro Presented by : Lambda Research Corporation 25 Porter Rd. Littleton, MA 01460 Moderator: Mike Gauvin Vice President of Sales and Marketing Lambda Research Corporation
More informationWe bring quality to light. LGS 350 Goniophotometer
We bring quality to light. LGS 350 Goniophotometer light measurement The features at a glance Type C goniophotometer with horizontal optical axis For samples up to max. 700 mm diameter and 8 kg weight
More informationWHITE PAPER. How to Generate a Ray Set from an RSMX Source Model. Zemax A Radiant Zemax Company
How to Generate a Ray Set from an RSMX Source Model How to Generate a Ray Set from an RSMX Source Model Introduction The most general description of a complex source is given in a Radiant Source Model
More informationDesign Verification and Analysis Tools in TracePro. Presented by : Lambda Research Corporation 25 Porter Rd. Littleton, MA
Design Verification and Analysis Tools in TracePro Presented by : Lambda Research Corporation 25 Porter Rd. Littleton, MA 01460 www.lambdares.com Moderator: Andy Knight Technical Sales Manager Lambda Research
More informationWHITE PAPER. Application of Imaging Sphere for BSDF Measurements of Arbitrary Materials
Application of Imaging Sphere for BSDF Measurements of Arbitrary Materials Application of Imaging Sphere for BSDF Measurements of Arbitrary Materials Abstract BSDF measurements are broadly applicable to
More informationLight Tec Scattering measurements guideline
Light Tec Scattering measurements guideline 1 Our Laboratory Light Tec is equipped with a Photometric Laboratory (a dark room) including: Goniophotometers: REFLET 180S. High specular bench (10 meters),
More informationLight Tec Scattering measurements guideline
Light Tec Scattering measurements guideline 1 Our Laboratory Light Tec is equipped with a Photometric Laboratory (a dark room) including: Goniophotometers: REFLET180s. High specular bench (10 meters),
More informationLight Tec Scattering measurements guideline
Light Tec Scattering measurements guideline 1 Our Laboratory Light Tec is equipped with a Photometric Laboratory (a dark room) including: Goniophotometers: REFLET 180S. High specular bench (10 meters),
More informationMODELING LED LIGHTING COLOR EFFECTS IN MODERN OPTICAL ANALYSIS SOFTWARE LED Professional Magazine Webinar 10/27/2015
MODELING LED LIGHTING COLOR EFFECTS IN MODERN OPTICAL ANALYSIS SOFTWARE LED Professional Magazine Webinar 10/27/2015 Presenter Dave Jacobsen Senior Application Engineer at Lambda Research Corporation for
More informationLight Tec Scattering measurements guideline
Light Tec Scattering measurements guideline 1 2 Light Tec Locations REFLET assembling plant, Aix-en-Provence, France Light Tec GmbH, Munich, Germany German office Light Tec Sarl, Hyères, France Main office
More informationOptisWorks. SolidWorks - integrated solutions for the modeling and perception of light
OptisWorks SolidWorks - integrated solutions for the modeling and perception of light OptisWorks for SolidWorks The complete simulation solution for the design, analysis, optimization and virtual prototyping
More informationInstruction manual for operating the Goniospectrometer in SSL Characterization
Aalto University School of Electrical Engineering Metrology Research Institute Janne Askola Instruction manual for operating Version 1.0 16/08/2016 Page 2 (7) Table of contents 1. Definition... 3 1.1.
More informationOptisWorks. SolidWorks - integrated solutions for the modeling and perception of light
OptisWorks SolidWorks - integrated solutions for the modeling and perception of light OptisWorks for SolidWorks The complete simulation solution for the design, analysis, optimization and virtual prototyping
More informationTips, Tricks, and Shortcuts to Improve Productivity and Efficiency with TracePro
Tips, Tricks, and Shortcuts to Improve Productivity and Efficiency with TracePro Presented by : Lambda Research Corporation 25 Porter Rd. Littleton, MA 01460 www.lambdares.com Moderator: Andy Knight Technical
More informationReflective Illumination for DMS 803 / 505
APPLICATION NOTE // Dr. Michael E. Becker Reflective Illumination for DMS 803 / 505 DHS, SDR, VADIS, PID & PLS The instruments of the DMS 803 / 505 series are precision goniometers for directional scanning
More informationScattering measurements. Guidelines for measurements service
Scattering measurements Guidelines for measurements service 1 Content Introduction Light Tec Presentation Instruments availalable. Scattering measurements Refelctors Diffusers Colors issuses Volume Scattering
More informationBridgelux ES Star Array Series
Bridgelux ES Star Array Series Product Data Sheet DS23 PRELIMINARY, Expires 12/15/11 BXRA-27x0540, BXRA-27x0740, BXRA-30x0540, BXRA-30x0740, BXRA-40E0810, BXRA-56C0700, BXRA-56C1000 Introduction The Bridgelux
More informationSpeeding Designs to Market with Zemax Virtual Prototyping. New Business Development Manager
Speeding Designs to Market with Zemax Virtual Prototyping Samuel Milns Chris Normanshire New Business Development Manager Engineering Services Manager, Europe Agenda What is Zemax Virtual Prototyping?
More informationMURA & DEFECT DETECTION WITH TrueTest
MURA & DEFECT DETECTION WITH TrueTest January 2015 1 OUTLINE The TrueTest system Quick introduction to TrueTest layout and structure TrueTest walk-through TrueTest gallery Summary 2 WHAT IS TRUETEST? A
More informationAdaptable Full-Color LED DMX Luminaire
TRIUMPH TR30 Adaptable Full-Color LED DMX Luminaire The Luxium TM TR30 is a unique LED lighting fixture with a DMX control system that merges an innovative high-output lighting module using 12 multi-color
More informationELECTRICAL LABORATORY- TEST REPORT Method of Electrical And Photometric Measurements of Solid State Lighting (LED) Products
ELECTRICAL LABORATORY- TEST REPORT Method of Electrical And Photometric Measurements of Solid State Lighting (LED) Products Test Report N. Date of issue Sample Date In.. Date of Performance. Applicant.
More informationLighting Database User Guide <Virtual Environment> 5.9
Lighting Database User Guide 5.9 Page 1 of 54 Contents 1. Lighting Database Overview...6 1.1. Access to the Lighting Database... 6 1.1.1. Select Light Fitting Command... 6 1.1.2.
More informationFlucsLDB: Lighting Database
FlucsLDB: Lighting Database User Guide IES Virtual Environment Copyright 2014 Integrated Environmental Solutions Limited. All rights reserved. No part of the manual is to be copied or reproduced in any
More informationTracePro Stray Light Simulation
TracePro Stray Light Simulation What Is Stray Light? A more descriptive term for stray light is unwanted light. In an optical imaging system, stray light is caused by light from a bright source shining
More informationUsing TracePro for LED Lighting Design Applications. Presented by : Lambda Research Corporation 25 Porter Rd. Littleton, MA
Using TracePro for LED Lighting Design Applications Presented by : Lambda Research Corporation 25 Porter Rd. Littleton, MA 01460 www.lambdares.com Moderator: Andy Knight Technical Sales Manager Lambda
More informationBridgelux V6 Array Series
Bridgelux V6 Array Series Product Data Sheet DS40 BXRE-xxx0400-A, BXRE-xxx0400-B Introduction The Bridgelux V6 LED Array products delivers high quality light in a compact and cost-effective solid-state
More informationPhotometric Test Report
Photometric Test Report Relevant Standards RIES LM-79-2008 RANSI C82.77:2014 Prepared For RAB Lighting Inc. Room 6A33, No.1388, Wuzhong road,shanghai,china Xiao Xiang,15921313292,gary@rabweb.com Prepared
More informationMicrosatellite Star Tracking Baffles: Validation and Testing
Microsatellite Star Tracking Baffles: Validation and Testing Martin Marciniak John Enright Tom Dzamba Ryerson University Doug Sinclair Sinclair Interplanetary 1 Purpose Star tracker baffles are designed
More informationWat is licht, wat is meten? Belgisch Perspectief! Spectraal of niet-spectraal meten: that s the question
Wat is licht, wat is meten? Belgisch Perspectief! Spectraal of niet-spectraal meten: that s the question IGOV kenniscafé Arnhem, 31 oktober 2013 Peter Hanselaer Light&Lighting Laboratory Introduction Spectral
More informationBridgelux ES Star Array Series
Bridgelux ES Star Array Series Data Sheet DS 21 Expiration date 10 May 2011 BXRB XXX0540-A, - XXX0740-A, - 40E0810-A, - 56C0700-A, - 56C1000-A Introduction The Bridgelux family of LED Array products delivers
More informationHow to Use the Luminit LSD Scatter Model
How to Use the Luminit LSD Scatter Model Summary: This article describes the characteristics and use of Luminit s LSD scatter model in OpticStudio. The scatter model presented here is the idealized scatter
More informationDMS 201 FEATURES LOW-COST MANUAL GONIOMETER SYSTEM
light measurement DMS 201 LOW-COST MANUAL GONIOMETER SYSTEM Turnkey solution for electrooptical display characterization for quality control, research and development. FEATURES Measurement and evaluation
More informationMeasuring Light: Radiometry and Photometry
Lecture 14: Measuring Light: Radiometry and Photometry Computer Graphics and Imaging UC Berkeley Radiometry Measurement system and units for illumination Measure the spatial properties of light New terms:
More informationPitch Illuminance Test Procedure
Pitch Illuminance Test Procedure In accordance with the regulations and requirements of the UEFA, an assessment of the pitch illuminance system of a venue which could potentially host a match for television
More informationLight Tec. Characterization of ultra-polished surfaces in UV and IR. ICSO October 2016 Biarritz, France
ICSO 2016 17-21 October 2016 Biarritz, France Light Tec Characterization of ultra-polished surfaces in UV and IR Quentin Kuperman, Author, Technical Manager Yan Cornil, Presenter, CEO Workshop 2016, 12/09
More informationRadiance, Irradiance and Reflectance
CEE 6100 Remote Sensing Fundamentals 1 Radiance, Irradiance and Reflectance When making field optical measurements we are generally interested in reflectance, a relative measurement. At a minimum, measurements
More informationEngineered Diffusers Intensity vs Irradiance
Engineered Diffusers Intensity vs Irradiance Engineered Diffusers are specified by their divergence angle and intensity profile. The divergence angle usually is given as the width of the intensity distribution
More informationStrada Lens Guide. Page 1
Page 1 Contents STRADA lens types... 3 Symmetric... 3 Asymmetric... 4 STRADA-T... 4 STRADA-SQ... 4 STRADA-F... 5 STRADA modules... 6 STRADA 2x2... 6 STRADA 6x1... 7 Mixing STRADA lenses... 8 IESNA type
More informationARCHISHAPE FIT Datasheet
Datasheet series is versatile lighting for ambient and cabinet illumination. With LED binning control to within 3 MacAdam steps, the luminaire offers perfect and consistent lighting effect. Extra short
More informationPHOTOMETER. Instruction Sheet for the PASCO Model OS Introduction. Equipment. How to Use the Photometer. Photometer
Instruction Sheet for the PASCO Model OS-8520 PHOTOMETER 012-05631A 3/95 $1.00 Neutral Density Filter Introduction The PASCO OS-8520 Photometer is a non-electric comparative instrument which was designed
More informationFL200 Monochromatic Architectural Spot and Floodlight
DATE: TYPE: COMPANY: PROJECT: 360 375mm 14.7in 463mm 18.2in 269mm 10.7in 421mm 16.6in 77mm 3.0in *SM bracket mounting option shown. See page 2 for more mounting options. FEATURES: OPTIONS: Over 16,500
More informationCHM-27 COB Arrays White LED
CHM-27 COB Arrays White LED Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Part number nomenclature. 4 Ordering part number and flux spec... 5 Operating
More informationFluxGage. FluxGage. LED Luminaire Measurement System User Manual
FluxGage FluxGage LED Luminaire Measurement System User Manual 1 Acronyms... 3 2 Introduction... 4 2.1 Operation principle... 4 3 Specifications... 5 4 Mechanical and Electrical Installation... 9 4.1 Unpacking...
More informationBridgelux Vero 18 Array Series
Bridgelux Vero 18 Array Series Product Data Sheet DS32 BXRC-17E4000, 25E4000, 27x4000, 30x4000, 35E4000, 40x4000, 50x4000, 56G4000 Introduction Vero TM represents a revolutionary advancement in chip on
More informationMu lt i s p e c t r a l
Viewing Angle Analyser Revolutionary system for full spectral and polarization measurement in the entire viewing angle EZContrastMS80 & EZContrastMS88 ADVANCED LIGHT ANALYSIS by Field iris Fourier plane
More informationLED Modules. Fortimo FastFlex
LED Modules Fortimo FastFlex 2x8/757 gen3 The Philips Fortimo FastFlex LED system gen 3 portfolio has been designed to offer a suitable solution to OEMs who want to distinguish themselves through their
More informationLucidShape Computer Aided Lighting Overview. Willi Brandenburg brandenburg gmbh
LucidShape Computer Aided Lighting Overview Willi Brandenburg brandenburg gmbh www.brandenburg-gmbh.de Overview Simulation LucidFunGeo Optic design Lit Appearance Optimizer Other Street lighting 2 Simulation
More informationCXM-9 COB Arrays White LED
CXM-9 COB Arrays White LED Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Product Ordering & Shipping Part Numbers...4 Part Numbers AA00...5 Part Numbers
More informationPRODUCTMEETING J U N E 1 ST 2017
PRODUCTMEETING J U N E 1 ST 2017 1 AGENDA POLARIS RAY RELEASE EROS 170/215 RELEASE RODA TEASER LATERNA RELEASE LATERNA FAMILY IMPORTANT UPDATE B-TRACK OVERVIEW UPDATE SPECTROMETER NEW TOOL INTEREST POLLS
More informationAdvanced Tutorial Designing a Linear Fluorescent Reflector with the Parametric Optical Design Tools
Advanced Tutorial Designing a Linear Fluorescent Reflector with the Parametric Optical Design Tools Prerequisites This tutorial is written with the assumption that you have already completed and understand
More informationAcuHue CC Series. sirs-e.com. Flexible RGBW LED Strip
AcuHue CC Series Flexible LED Strip The SIS-E AcuHue CC LED strip series, utilizes Constant Current Control to provide for ideal color consistency with no brightness loss or voltage drop through the use
More informationStudio. CVM Studio COB Arrays LED Entertainment Lighting. CVM Product Datasheet Preliminary. Features: Table of Contents.
Studio CVM Product Datasheet CVM Studio COB Arrays LED Entertainment Lighting Features: Table of Contents Technology Overview.... 2 Test Specifications... 2 Chromaticity Bins.... 3 Product Ordering & Shipping
More informationVaya Tube, White & Mono (On-Off)
Vaya Tube, White & Mono (On-Off) Vaya Tube White & Mono is a reliable and cost effective direct view linear LED lighting fixture designed for exterior accent and contour lighting applications. The slim
More informationCXM-9 COB Arrays White LED
CXM-9 COB Arrays White LED Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Product Ordering & Shipping Part Numbers...4 Part Numbers AA00...5 Part Numbers
More informationGeneration 3 CXM-14 COB Arrays White LED
Generation 3 CXM-14 COB Arrays White LED Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Product Ordering & Shipping Part Numbers...4 Customer Part Numbers...5
More informationGeneration 3 CXM-9 COB Arrays White LED
Generation 3 CXM-9 COB Arrays White LED Features: Table of Contents Technology Overview......2 Test Specifications.........2 Chromaticity Bins..........3 Product Ordering & Shipping Part Number nomenclature.4
More informationGeneration 3 CXM-27 COB Arrays White LED
Generation 3 CXM-27 COB Arrays White LED Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Product Ordering & Shipping Part Numbers...4 Product Typical Flux
More informationGeneration 3 CLM-14 COB Arrays White LED
Generation 3 CLM-14 COB Arrays White LED Features: Table of Contents Technology Overview......2 Test Specifications.........2 Chromaticity Bins..........3 Product Ordering & Shipping Part Numbers..............4
More informationBridgelux Vero 18 Array Series
Bridgelux Vero 18 Array Series Product Data Sheet DS32 Published July 18 th 2013 BXRC-27x4000, BXRC-30x4000, BXRC-35E4000, BXRC-40E4000, BXRC-50C4000 Introduction Vero TM represents a revolutionary advancement
More informationIllumination Design, Analysis, and Optimization Software
SUPERIOR OPTO-MECHANICAL SOFTWARE Illumination Design, Analysis, and Optimization Software TracePro is award-winning opto-mechanical software used for design, analysis, and optimization of optical and
More informationCHM-11-XH00 LED High Density White COB Array
CHM-11 Product Datasheet CHM-11-XH00 LED High Density White COB Array Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Product Ordering & Shipping Part
More informationGeneration 3 CIM-9 COB Arrays White LED
Preliminary Generation 3 CIM-9 COB Arrays White LED Features: Table of Contents Technology Overview......2 Test Specifications.........2 Chromaticity Bins..........3 Product Ordering & Shipping Part Number
More informationGeneration 2 CXM-27 COB Arrays White LED
CXM-27 Product Datasheet Generation 2 CXM-27 COB Arrays White LED Features: High lumen output and efficacy typical Table of Contents Over 8,300 lm, over 134 LPW @ 3000K, 80CRI, 85ºC Technology Overview......2
More informationGeneration 3 CXM-14 COB Arrays White LED
Generation 3 CXM-14 COB Arrays White LED Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Product Ordering & Shipping Part Numbers...4 Customer Part Numbers...5
More informationModel S471 Portable Optometer
Model S471 Portable Optometer With over 50 years of experience in developing light measurement instruments, Gamma Scientific is trusted by the world s leading organizations to provide accurate results.
More informationPHOTOMETRIC DATA FOR THE DEVELOPMENT OF LIGHTING COMPONENTS. Knut Bredemeier. TechnoTeam Bildverarbeitung GmbH
59 th ILMENAU SCIENTIFIC COLLOQUIUM Technische Universität Ilmenau, 11 15 September 2017 URN: urn:nbn:de:gbv:ilm1-2017iwk-138:9 PHOTOMETRIC DATA FOR THE DEVELOPMENT OF LIGHTING COMPONENTS Knut Bredemeier
More informationGeneration 3 CLM-9 COB Arrays White LED
Preliminary Generation 3 CLM-9 COB Arrays White LED Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Product Ordering & Shipping Part Numbers...4 Part Numbers...5
More informationHarold Brunt Optomechanical Designer, Corporate Officer, VP LumenFlow Corp. Board Member, United Lumen, LLC
6/22/2017 1 Harold Brunt Optomechanical Designer, Corporate Officer, VP LumenFlow Corp. Board Member, United Lumen, LLC LumenFlow Corp. is a Photonics Engineering, Consulting and small manufacturing company
More informationSALIOT Track Light Datasheet
Datasheet SALIOT, the most flexible track light with Bluetooth remote control of beam angle and irradiation direction. The integration of preeminent optics, motor, and wireless communication technologies,
More informationCHM-9 COB Arrays White LED
CHM-9 COB Arrays White LED Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Product Ordering & Shipping Part Numbers...4 Part Numbers AA00...5 Part Numbers
More informationBridgelux Vero 29 Array Series
Bridgelux Vero 29 Array Series Product Data Sheet DS33 BXRC-27x10K0, 30x10K0, 35x10K0, 40x10K0, 50x1000, 56G10K0 Introduction Vero TM represents a revolutionary advancement in chip on board (COB) light
More informationMeasuring Light: Radiometry and Photometry
Lecture 10: Measuring Light: Radiometry and Photometry Computer Graphics and Imaging UC Berkeley CS184/284A, Spring 2016 Radiometry Measurement system and units for illumination Measure the spatial properties
More informationLumen Maintenance of LED Light Source Test Report
Lumen Maintenance of LED Light Source Test Report This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005. This accreditation demonstrates technical competence
More informationGeneration 3 CXM-11 LED White COB Arrays
CXM-11 Gen 3 Product Datasheet Generation 3 CXM-11 LED White COB Arrays Features: Table of Contents Technology Overview......2 Test Specifications.........2 Chromaticity Bins..........3 Product Ordering
More informationGeneration 3 CHM-9 COB Arrays White LED
Generation 3 CHM-9 COB Arrays White LED Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Product Ordering & Shipping Part Numbers...4 Part Numbers...5 Operating
More informationFL50 RGBW Inner Mixing Architectural Spot and Floodlight
Color mixing in a single optic for wall washing/grazing applications and color compatibility with STR9 RGBW fixtures. DATE: TYPE: COMPANY: PROJECT: 360 78mm 3.1in 228mm 9.0in 11.9in 271mm 251mm 9.9in 85mm
More informationDMS 903 FEATURES GONIOMETER SYSTEM FOR COMPLETE DISPLAY CHARACTERIZATION
light measurement DMS 903 GONIOMETER SYSTEM FOR COMPLETE DISPLAY CHARACTERIZATION Turnkey solution with motorized scanning for detailed electrooptical display characterization of large-area displays for
More informationInterior. Exterior. Daylight
Interior Exterior Daylight Page 2 ElumTools is a fully-integrated lighting calculation Add-in for Autodesk Revit authored by Lighting Analysts, Inc. The growth of BIM (Building Information Modeling) software
More informationLED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE
Module SLA DC G2 5mm SNC Modules SLA ESSENCE Product description Fits in most existing MR16 / GU1 halogen luminaires Replacement of 5 W MR16 halogen lamps or 2 W HID lamp Module with integrated heatsink
More informationDESIGNING A SIMPLE OPTICAL SYSTEM IN LIGHTTOOLS
DESIGNING A SIMPLE OPTICAL SYSTEM IN LIGHTTOOLS Liliana Ruiz Diaz December 08, 2016 College of Optical Sciences, University of Arizona, Tucson, AZ USA 85721 WHAT IS LIGHTTOOLS LightTools is a 3D optical
More informationLighting Simulation Tools in the process of design. Laleh Amany Autumn 2017
Lighting Simulation Tools in the process of design Laleh Amany Autumn 2017 Lighting simulation is important for architectural projects from multiple p e r s p e c t i v e f o r c o n c e p t i o n a n
More informationExperiment 6. Snell s Law. Use Snell s Law to determine the index of refraction of Lucite.
Experiment 6 Snell s Law 6.1 Objectives Use Snell s Law to determine the index of refraction of Lucite. Observe total internal reflection and calculate the critical angle. Explain the basis of how optical
More informationEcoSpec Floodlight Wash
EcoSpec Floodlight Wash is a powerful architectural floodlight and landscape luminaire offering superior binning and a full range of optical solutions. The EcoSpec Floodlight Wash is indoor and outdoor
More informationInterference of Light
Lecture 22 Chapter 22 Physics II Wave Optics: Interference of Light Course website: http://faculty.uml.edu/andriy_danylov/teaching/physicsii Wave Motion Interference Models of Light (Water waves are Easy
More informationLight distribution curves, illumination and isolux diagrams
Light distribution curves, illumination and isolux diagrams 77 986 77 97 77 831 β = 5 /7 cd/klm 1 36 cd/klm C 18 - C C 7 - C 9 C 195 - C 15 3 6 3 3 6 Fig. 1 Fig. 5 Light distribution curves Careful planning
More informationBOSSA NOVA TECHNOLOGIES,
SAMBA Hair System Objective measurement of parameters involved in the visual appearance of hair BOSSA NOVA TECHNOLOGIES, California Robert George - Sebastien Breugnot Company Overview Located in Los Angeles
More informationGeneration 3 CXM-22 COB Arrays White LED
CXM-22 Product Datasheet Generation 3 CXM-22 COB Arrays White LED Features: High lumen output and efficacy typical Table of Contents Over 8,280 lm, 148 LPW @ 3000K, 80 CRI, Tj = 85ºC Technology Overview......
More informationPARATHOM PAR16. Product family datasheet. LED reflector lamps PAR16 with retrofit pin base
PARATHOM PAR16 LED reflector lamps PAR16 with retrofit pin base Areas of application _ Spotlighting for accents _ Display cabinets and shop windows _ Retail outlets and exhibition rooms _ Spotlighting
More informationMN/DOT Specification Light Emitting Diode (LED) Luminaire For Roadway Lighting Underpass Applications 04/02/2015
MN/DOT Specification Light Emitting Diode (LED) Luminaire For Roadway Lighting Underpass Applications 04/02/2015 1. LISTING REQUIREMENTS 1.1. The Luminaire shall be listed by a National Recognized Testing
More informationComplete solutions for measuring luminous flux and color maintenance of LED packages, arrays and modules VEKTREX LM-80 SYSTEMS
High-performance LED test solutions. VEKTREX LM-80 SYSTEMS Complete solutions for measuring luminous flux and color maintenance of LED packages, arrays and modules mbers iltering pliant Test oftware g
More informationFRED Display Application Note
FRED Display Application Note Most displays consist of several optical components. The most important component is the source of light that illuminates the display. All displays need a mechanism to send
More informationLED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE
Module SLA DC G2 5mm SNC Modules SLA ESSENCE Product description Fits in most existing MR16 / GU1 halogen luminaires Replacement of 5 W MR16 halogen lamps or W HID lamp Module with integrated heatsink
More informationDMS 803 FEATURES OPTIONS GONIOMETER SYSTEM FOR COMPLETE DISPLAY CHARACTERIZATION
GONIOMETER SYSTEM FOR COMPLETE DISPLAY CHARACTERIZATION Turnkey solution with motorized scanning for detailed electro-optical display characterization for quality control, research and development. FEATURES
More informationMNDOT Specification Light Emitting Diode (LED) Luminaire For Roadway Lighting at a Mounting Height of 49 Feet 10/14/2015
1. LISTING REQUIREMENTS MNDOT Specification Light Emitting Diode (LED) Luminaire For Roadway Lighting at a Mounting Height of 49 Feet 10/14/2015 1.1. The Luminaire shall be listed by a National Recognized
More informationPRODUCT FAMILY DATASHEET LEDVANCE PANEL LED DALI 1200x300
LEDVANCE PANEL LED DALI 1200x300 LED panel luminaires with DALI AREAS OF APPLICATION Direct replacement for luminaires with fluorescent lamps Corridors Offices Conference rooms Reception areas Foyers PRODUCT
More informationVisual 2012 Help Index
Visual 2012 Help Index Absolute Coordinates 2.1 Cartesian Coordinates Aim 7.4.3 Place and Aim Luminaires 7.4.4 Reaiming Luminaires Align Cursor and Plane to Current View 9.6 Align to View Align Cursor
More informationROBLITZ Highbay SE Datasheet
Datasheet ROBLITZ Highbay SE series is highly efficient and reliable LED highbay. With very high system efficacy up to 130 lm/w thanks to the state-of-the-art LED technology. It offers flexible options
More informationCXM-6 COB Arrays White LED
CXM-6 COB Arrays White LED Features: Table of Contents Technology Overview...2 Chromaticity Bins...3 Product Ordering & Shipping Part Numbers...4 Product Typical Flux Range. 5 Product Flux Bins...6 Operating