Application of 450 kv Computed Tomography to Engine Blocks with Steel Liners

Size: px
Start display at page:

Download "Application of 450 kv Computed Tomography to Engine Blocks with Steel Liners"

Transcription

1 Application of 450 kv Computed Tomography to Engine Blocks with Steel Liners Charles R. Smith, Kevin Holt BIR, Inc. Uwe Bischoff, Bernd Georgi, Ferdinand Hansen, Frank Jeltsch Volkswagen Commercial Vehicles ABSTRACT The most common type of Computed Tomography (CT) system deployed in the automotive industry for inspection of aluminum castings today uses a 450 kv x-ray source. These systems are quite suitable for inspection of cylinder heads, transmission cases and other medium size parts with little or no embedded steel or other dense metals. As a general rule, parts with maximum path lengths of 264 mm in aluminum or 82 mm in steel can be successfully inspected at 450 kv. Achieving excellent image quality on larger parts with longer path lengths such as engine blocks with steel liners normally requires the use of a linear accelerator producing x-rays at 2 MV or higher. Such installations are not common at industrial sites due to high cost, large size, and operational safety considerations. Recent developments in mathematical processing algorithms for correction of CT data have facilitated the imaging of larger aluminum parts with long path lengths and embedded heavy metals. Prior to these new corrections, the results from 450 kv systems were unsatisfactory due to distortion, noise, and artifacts in the images. We present before and after images showing the improvements gained from these additional processing steps. technology to inspect parts, improve designs, monitor processes, measure dimensions, and improve quality. CT inspection has been most commonly applied to light metal castings such as aluminum cylinder heads and blocks. The most promising usage of CT systems so far is the capability to simultaneously perform dimensional checking and flaw detection in one inspection. The complex internal geometries, critical dimensional tolerances, and thin wall structures of today s high performance engines are forcing casting suppliers to be more competitive while keeping costs in check. If raw castings with bad dimensions or critical internal defects slip through the initial inspection processes, they may fail other tests downstream after machining, labor, handling, and other similar operations have added value. The potential for CT to reduce the amount of defects, scrap, and rework is a potential source of significant cost savings. Critical defects missed by conventional inspection processes can lead to warranty claims and costs at a later date. These costs can also be reduced by CT while improving reliability. A typical automotive CT system specifically designed for in-line inspection of castings is shown in Figure 1. Three specific correction methods are presented: global noise filtering, adaptive noise filtering, and ring artifact suppression applied to raw data. The physical basis of each correction is discussed along with the mathematical theory. A new version of software incorporating these additional correction steps has been issued to existing 450 kv systems, enabling them to expand their scope of applications beyond the original specifications and design goals. INTRODUCTION There has been a steady growth of automotive manufacturers using CT technology from the mid 1980 s in Japan, Europe in the mid 1990 s, Korea in the past few years, and now in China. These manufacturers use the Figure 1. A 450kV In-Line CT system for automotive casting inspection is shown..

2 The most prevalent type of CT system in the automotive industry uses an x-ray system operating at a maximum energy of 450 kv. The upper limit of 450 kv is a historical one imposed by the interconnection system between the high voltage power supplies and the x-ray tube. We can predict the maximum practical path lengths in aluminum or steel for CT inspection with a 450 kv x-ray tube using the equation for the basic law of radiation attenuation: I μx = I 0 e (Eq. 1) where I o is the x-ray flux entering the part, I is the x-ray flux exiting the part, μ is the attenuation coefficient of the material (in units of cm -1 ), and x is the path length through the part in cm. However, Eq. 1 as given is only accurate for a single x-ray photon energy, whereas practical x-ray sources produce a broad spectrum of energies up to the maximum accelerating potential of 450 kv. A reasonable approximation that works well in practice is to model the source as mono-energetic at half the maximum energy. The attenuation coefficients of aluminum and steel are therefore found for 225 kv using Mucal on the Web, 1 a shareware program at From Mucal, the attenuation coefficients for aluminum and iron are cm -1 and cm -1 respectively at 225 kv. Based on practical experience with real parts and actual CT systems, good quality images are possible when the attenuation in the maximum path length is less than 5,000. Solving Eq. 1 then for the path lengths of Al and Fe that give attenuations of 5,000 (I 0 /I), we find the maximum practical path lengths of Al and Fe are 264 mm and 82 mm. Longer path lengths typically cause significant artifacts due to beam hardening and photon starvation. This is especially a problem for engine blocks with steel liners where path lengths in steel are often 125 mm or longer. Beam hardening is preferential absorption of the low energy portion of the x-ray beam in the first few cm while traversing a long path. The emergent beam from a long path thus has an average energy significantly higher than the assumed average of 225 kv. This higher energy beam is more easily able to penetrate the remainder of the path and effectively makes the entire long path appear less dense than normal since practical CT reconstruction algorithms use the same mono-energetic assumption as Eq 1. The result is that beam hardening creates density type shading errors in the CT images, which adversely affect measurement accuracy but still allow for flaw detection interpretation. Photon starvation is a more severe problem leading to streaks that render images unusable. Photon starvation occurs when the signal arriving at the detector is below the electronic noise level of the data acquisition system so the resulting output goes to zero or nearly so. Zero values occurring in very low level data appear as noise spikes. The filtered back-projection method of image reconstruction used in commercial CT systems convolves the raw data with a filter kernel that effectively causes a certain degree of edge enhancement. The photon starvation noise spikes in the low level portion of the raw data are amplified by the convolution step of reconstruction resulting in significant streak artifacts in the finished image. This is illustrated in Figure 2. Figure 2. Streak artifacts due to photon starvation on long steel paths are shown. An in-line four cylinder engine block with steel liners was imaged at 445 kv. Raising the energy level of the x-ray source to avoid photon starvation is one solution to the streak artifact problem. At higher energies, the attenuation coefficients are reduced so penetration is improved. Since high energy sources produce much higher flux rates than x-ray tubes, the low energy portion of the spectrum can be filtered out to reduce the effects of beam hardening. A 6 MV accelerator can penetrate path lengths of 850 mm and 275 mm in aluminum and steel. An example of a V6 engine block CT image taken at 6 MV using a linear accelerator is shown in Figure 3.

3 Figure 3. A 6 MV CT image of a V6 engine block with steel liners is shown. Artifacts such as photon starvation streaks and beam hardening shading are minimized. Accelerator CT systems are a good solution in terms of improved image quality. Their use in the automotive industry has been limited by significantly higher system and shielding costs. CT DATA COLLECTION CT systems create cross section images by collecting radiographic images at multiple positions around the part. Single row line array detector based systems used for casting inspection normally collect data at regular angular increments while the part is rotated through 360. CT system data is displayed in a coordinate system of turntable angular increment on the Y axis and detector channel number on the X axis. This data presentation is known as a sinogram since features away from the center of the turntable describe sinusoidal functions. An example sinogram from the image of Figure 2 is shown in Figure 4. The streak artifacts in the 450 kv image of Figure 2 are caused by low level signals through the steel liners and long aluminum paths seen in the sinogram as black areas. ARTIFACT REDUCTION BY DATA CORRECTIONS Software correction of CT data prior to image formation improves image quality by minimizing problems due to the physical measurement system. Three separate methods designed to improve signal to noise ratio without reducing spatial resolution are presented. The goal is extension of existing CT systems to a wider variety of applications including engine blocks. Figure 4. The sinogram data from a CT scan is shown. The Y axis is turntable angle and the X axis is detector channel number. Off-center features produce sinusoidal functions in the data. Sinogram Data Median Filter CT systems operate in environments with high electrical noise. High power pulse-width modulated servo drives are often sources of RFI noise. The 450 kv x-ray systems also are capable of generating large transient electrical noise spikes. Despite judicious shielding and good grounding practice being used on sensitive low level signals in the detector array, noise spikes are sometimes seen in sinograms that cause streaks in images. We take advantage of the knowledge that the response of the detector system is limited by its modulation transfer function. 2. Knowing the output of a given detector channel cannot change by more than a certain amount from one reading to the next, we can infer that outliers and spikes in the data are caused by noise injected into the system. These noise spikes are eliminated by median or rank order filtering the sinogram. The weighted median filter 3 (WMF) used here is a 3x3 mask operator applied to the sinogram. The nine data points covered by the operator are rank ordered from lowest to highest value and the central data point is given greater weight by having multiple entries in the ordered list. The original center data point of the sinogram is replaced by the middle data point in the rank ordered list. The WMF operator removes single occurrences of noise spikes while preserving edge data. The CT image signal to noise ratio is improved with no loss of resolution.

4 Sinogram Data Adaptive Noise Filter When photon starvation occurs due to long path lengths or dense material, the detector signal will drop to zero output for more than one data point in a row. In this case, median filtering is not effective and severe streaking occurs in the images as seen in Figure 2. An additional method that is successful at eliminating photon starvation streaks has been developed for medical CT and has now been applied to the industrial case. In this case, different size Gaussian shaped filter kernels are convolved with the sinogram data based on signal level. Convolution of a filter kernel K with an image I is mathematically expressed as m n O( i, j) = I ( i + k 1, j + l 1) K ( k, l) Eq 2 k = 1 l= 1 where the output pixel is O(i,j) and the filter kernel size is m x n. Gaussian shaped kernels are chosen for their noise smoothing characteristics. Based on a heuristic algorithm, sinogram data is segmented into several bands according to signal level. The band of data at the lowest signal level is filtered with the largest size kernel and thus experiences the greatest degree of smoothing. At higher signal levels, the kernel size is progressively reduced with an attendant reduction of smoothing. The objective of the method is to selectively filter only those areas of the data causing objectionable streaks due to photon starvation while avoiding global smoothing of the data with its corresponding loss of spatial resolution. Ring Artifact Removal in Sinogram Data One of the characteristic problems of all CT systems using data collection based on relative rotational motion between the object and the source-detector assembly is circular ring artifacts in the images. Circles in the image are caused by vertical lines or line segments in the sinogram data due to many factors such as incorrect calibration, 5 detector housing temperature drift, non-linear behavior of detector scintillator material, channel to channel variation of detector array output, mechanical misalignment between the x-ray source and detector, etc. System hardware is normally designed to mitigate ring artifact problems, but is not always capable of perfect performance, especially in the case of industrial applications where a wide variety of materials, energy ranges, and part sizes are encountered on any given system. Therefore, software corrections for ring artifacts have been developed. For portions of the sinogram containing air (i.e. the white areas in Figure 4), standard gain calibration usually does a good job of preventing major rings when performed properly. However, many of the more unmanageable causes of rings manifest as partial vertical lines concentrated inside the shaded areas of the sinogram the areas which contain the information important to making the CT reconstruction. The challenge posed to correction algorithms is to identify and remove these partial lines from the sinogram without removing part of the object itself. The correction used here works by first smoothing the sinogram data to combat noise. Then, for each datum in the sinogram, a fit is performed on the data in a small surrounding neighborhood to determine the expected value of that datum. The difference between the measured value and expected value is calculated, and the result is a ring-candidate sinogram. The ring-candidate sinogram contains many vertical lines in general it will contain most if not all of the actual rings, as well as a large number of vertical lines corresponding to objectfeatures. A heuristic algorithm then evaluates these vertical lines based on the strength, length, and connectedness of each line, and separates the lines into ring-components and object-features. The ringcomponents are then assembled into a rings-only sinogram, which is subtracted from the original sinogram to provide the corrected data. RESULTS An in-line four cylinder engine block having steel liners was scanned at the following parameters X-ray Technique: 445 kv, 2 ma., small focus; Slice Thickness: 1 mm at the part center; Number of Views: 800; Time per Slice: 26 seconds; Image Matrix & Diameter: , 400 mm. Scans made with these parameters have streak and ring artifacts that mask real defects (see Figure 2). These problems are caused by the steel path lengths exceeding the penetration capability the 450 kv source as determined by Equation 1. When the sinogram based corrections of Median Filter, Adaptive Noise Filter, and Ring Removal are applied to the data, the image is improved to the level seen in Figure 5. While image quality is not perfect, streak and ring removal reveals flaw conditions. Porosity is seen in the center left area of the casting at nine o clock in Figure 5. This region is expanded in Figure 6.

5 ACKNOWLEDGMENTS We wish to thank Dr. Bernd Georgi and Dr. Ferdinand Hansen of Volkswagen Commercial Vehicles, Hanover for supplying the engine block shown in Figures 2, 3, 5, and 6. Figure 5. The engine block section of Figure 2 is shown after the sinogram data corrections of Median Filter, Adaptive Noise Filter, and Ring Removal. Artifacts are reduced so flaw detection is now possible. REFERENCES 1. Pathikrit Bandyopadhyay, Mucal on the Web ( Center for Synchrotron Radiation & Research, Illinois Institute of Technology, Chicago, 1995). 2. Standard Test Method for Measurement of Computed Tomography (CT) System Performance, ASTM E , ASTM International, Philadelphia, 2005, pg Yin, L., Yang, R, Gabbouj, M., Neuvo, Y., Weighted Median Filters: A Tutorial, IEEE Trans. on Circuits and Systems 43(3): March 1996, pp Russ, John C., The Image Processing Handbook, CRC Press, New York, 2002, pg Raven, C., Numerical Removal of Ring Artifacts in Microtomography, Review of Scientific Instruments 69(8): Aug 1998, pg Figure 6. The left center portion of Figure 5 is expanded to show porosity in detail. The largest flaw measures 1.1 mm horizontally by 3.8 mm vertically. CONCLUSION Software based corrections of CT data have been designed to improve image quality for extreme application with long path lengths and dense materials that are normally quite difficult to image unless thick slices, long integration times, and the large focal spot are used. The utility of CT as an inspection technique has been improved by issuing a new revision of software to existing systems at customer sites.

Ch. 4 Physical Principles of CT

Ch. 4 Physical Principles of CT Ch. 4 Physical Principles of CT CLRS 408: Intro to CT Department of Radiation Sciences Review: Why CT? Solution for radiography/tomography limitations Superimposition of structures Distinguishing between

More information

Digital Image Processing

Digital Image Processing Digital Image Processing SPECIAL TOPICS CT IMAGES Hamid R. Rabiee Fall 2015 What is an image? 2 Are images only about visual concepts? We ve already seen that there are other kinds of image. In this lecture

More information

CT INSPECTION OF CASTINGS WITH IMPROVED CALIBRATION

CT INSPECTION OF CASTINGS WITH IMPROVED CALIBRATION Copyright 2004 SAE International O5M-498 CT INSPECTION OF CASTINGS WITH IMPROVED CALIBRATION Charles R. Smith, Kyung S. Han BIR Inc Uwe Bischoff, Bernd Georgi, Ferdinand Hansen, Frank Jeltsch Volkswagen

More information

CoE4TN4 Image Processing. Chapter 5 Image Restoration and Reconstruction

CoE4TN4 Image Processing. Chapter 5 Image Restoration and Reconstruction CoE4TN4 Image Processing Chapter 5 Image Restoration and Reconstruction Image Restoration Similar to image enhancement, the ultimate goal of restoration techniques is to improve an image Restoration: a

More information

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control Oliver BRUNKE 1,

More information

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control 6 th International Congress of Metrology, 06003 (203) DOI: 0.05/ metrology/20306003 C Owned by the authors, published by EDP Sciences, 203 A new Concept for High-Speed atline and inlinect for up to 00%

More information

Coordinate Measuring Machines with Computed Tomography

Coordinate Measuring Machines with Computed Tomography Always a Step Ahead with Quality Coordinate Measuring Machines with Computed Tomography Multisensor Coordinate Measuring Machines with Computed Tomography Computed Tomography in Coordinate Measuring Machines

More information

A new concept for high-speed atline and inline CT for up to 100% mass production process control allowing both 3D metrology and failure analysis

A new concept for high-speed atline and inline CT for up to 100% mass production process control allowing both 3D metrology and failure analysis A new concept for high-speed atline and inline CT for up to 100% mass production process control allowing both 3D metrology and failure analysis Oliver Brunke 1, Ferdinand Hansen 2, Ingo Stuke 3, Friedrich

More information

Recognition and Measurement of Small Defects in ICT Testing

Recognition and Measurement of Small Defects in ICT Testing 19 th World Conference on Non-Destructive Testing 2016 Recognition and Measurement of Small Defects in ICT Testing Guo ZHIMIN, Ni PEIJUN, Zhang WEIGUO, Qi ZICHENG Inner Mongolia Metallic Materials Research

More information

Identification of Shielding Material Configurations Using NMIS Imaging

Identification of Shielding Material Configurations Using NMIS Imaging Identification of Shielding Material Configurations Using NMIS Imaging B. R. Grogan, J. T. Mihalczo, S. M. McConchie, and J. A. Mullens Oak Ridge National Laboratory, P.O. Box 2008, MS-6010, Oak Ridge,

More information

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques SINCE2013 Singapore International NDT Conference & Exhibition 2013, 19-20 July 2013 Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image

More information

CIVA Computed Tomography Modeling

CIVA Computed Tomography Modeling CIVA Computed Tomography Modeling R. FERNANDEZ, EXTENDE, France S. LEGOUPIL, M. COSTIN, D. TISSEUR, A. LEVEQUE, CEA-LIST, France page 1 Summary Context From CIVA RT to CIVA CT Reconstruction Methods Applications

More information

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY David K. Lehmann 1, Kathleen Brockdorf 1 and Dirk Neuber 2 1 phoenix x-ray Systems + Services Inc. St. Petersburg, FL, USA 2 phoenix x-ray Systems + Services

More information

Introduction to Biomedical Imaging

Introduction to Biomedical Imaging Alejandro Frangi, PhD Computational Imaging Lab Department of Information & Communication Technology Pompeu Fabra University www.cilab.upf.edu X-ray Projection Imaging Computed Tomography Digital X-ray

More information

Joint ICTP-TWAS Workshop on Portable X-ray Analytical Instruments for Cultural Heritage. 29 April - 3 May, 2013

Joint ICTP-TWAS Workshop on Portable X-ray Analytical Instruments for Cultural Heritage. 29 April - 3 May, 2013 2455-5 Joint ICTP-TWAS Workshop on Portable X-ray Analytical Instruments for Cultural Heritage 29 April - 3 May, 2013 Lecture NoteBasic principles of X-ray Computed Tomography Diego Dreossi Elettra, Trieste

More information

Artifact Mitigation in High Energy CT via Monte Carlo Simulation

Artifact Mitigation in High Energy CT via Monte Carlo Simulation PIERS ONLINE, VOL. 7, NO. 8, 11 791 Artifact Mitigation in High Energy CT via Monte Carlo Simulation Xuemin Jin and Robert Y. Levine Spectral Sciences, Inc., USA Abstract The high energy (< 15 MeV) incident

More information

Central Slice Theorem

Central Slice Theorem Central Slice Theorem Incident X-rays y f(x,y) R x r x Detected p(, x ) The thick line is described by xcos +ysin =R Properties of Fourier Transform F [ f ( x a)] F [ f ( x)] e j 2 a Spatial Domain Spatial

More information

Corso di laurea in Fisica A.A Fisica Medica 4 TC

Corso di laurea in Fisica A.A Fisica Medica 4 TC Corso di laurea in Fisica A.A. 2007-2008 Fisica Medica 4 TC Computed Tomography Principles 1. Projection measurement 2. Scanner systems 3. Scanning modes Basic Tomographic Principle The internal structure

More information

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE Rajesh et al. : Proceedings of the National Seminar & Exhibition on Non-Destructive Evaluation DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE Rajesh V Acharya, Umesh Kumar, Gursharan

More information

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa TOWARDS ESTABLISHMENT OF STANDARDIZED PRACTICE FOR ASSESSMENT OF SPATIAL RESOLUTION AND CONTRAST OF INTERNATIONAL

More information

DUE to beam polychromacity in CT and the energy dependence

DUE to beam polychromacity in CT and the energy dependence 1 Empirical Water Precorrection for Cone-Beam Computed Tomography Katia Sourbelle, Marc Kachelrieß, Member, IEEE, and Willi A. Kalender Abstract We propose an algorithm to correct for the cupping artifact

More information

Quality control phantoms and protocol for a tomography system

Quality control phantoms and protocol for a tomography system Quality control phantoms and protocol for a tomography system Lucía Franco 1 1 CT AIMEN, C/Relva 27A O Porriño Pontevedra, Spain, lfranco@aimen.es Abstract Tomography systems for non-destructive testing

More information

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM M. Simon, C. Sauerwein, I. Tiseanu, S. Burdairon Hans Wälischmiller GmbH Klingleweg 8, D-88709 Meersburg, Germany e-mail: ms@hwm.com ABSTRACT A new flexible

More information

Combining Analytical and Monte Carlo Modelling for Industrial Radiology

Combining Analytical and Monte Carlo Modelling for Industrial Radiology 19 th World Conference on Non-Destructive Testing 2016 Combining Analytical and Monte Carlo Modelling for Industrial Radiology Carsten BELLON, Gerd-Rüdiger JAENISCH, Andreas DERESCH BAM Bundesanstalt für

More information

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL Developments in Dimensional Metrology in X-ray Computed Tomography at NPL Wenjuan Sun and Stephen Brown 10 th May 2016 1 Possible factors influencing XCT measurements Components Influencing variables Possible

More information

TEP Hounsfield units. Related topics Attenuation coefficient, Hounsfield units

TEP Hounsfield units. Related topics Attenuation coefficient, Hounsfield units Hounsfield units TEP Related topics Attenuation coefficient, Hounsfield units Principle Depending on the type of CT scanner and the settings, the result of a CT scan of the same material can be different

More information

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

C a t p h a n / T h e P h a n t o m L a b o r a t o r y C a t p h a n 5 0 0 / 6 0 0 T h e P h a n t o m L a b o r a t o r y C a t p h a n 5 0 0 / 6 0 0 Internationally recognized for measuring the maximum obtainable performance of axial, spiral and multi-slice

More information

Beam Attenuation Grid Based Scatter Correction Algorithm for. Cone Beam Volume CT

Beam Attenuation Grid Based Scatter Correction Algorithm for. Cone Beam Volume CT 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Beam Attenuation Grid Based Scatter Correction Algorithm for More Info at Open Access Database

More information

3D Computed Tomography (CT) Its Application to Aerospace Industry

3D Computed Tomography (CT) Its Application to Aerospace Industry 3D Computed Tomography (CT) Its Application to Aerospace Industry C. Muralidhar, M. P. Subramanian, V. Ravi Shankar and G. Chandrasekhar Directorate of Non Destructive Evaluation, Defence Research & Development

More information

CT Systems and their standards

CT Systems and their standards CT Systems and their standards Stephen Brown Engineering Measurement 11 th April 2012 Industrial X-ray computed tomography: The future of co-ordinate metrology? Burleigh Court, Loughborough University

More information

CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects

CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects Tong LIU 1, Brian Stephan WONG 2, Tai

More information

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada Overview Introduction Overview Introduction Tecniques of imaging in Overview Introduction Tecniques of imaging

More information

Advanced automated High Speed Computed Tomography for production process control. DGZfP 2011, Bremen

Advanced automated High Speed Computed Tomography for production process control. DGZfP 2011, Bremen DGZfP-Jahrestagung 2011 - Mo.3.B.3 Advanced automated High Speed Computed Tomography for production process control DGZfP 2011, Bremen Dr. Ingo Stuke* and Dr. Oliver Brunke** GE Sensing & Inspection Technologies

More information

GENERAL AUTOMATED FLAW DETECTION SCHEME FOR NDE X-RAY IMAGES

GENERAL AUTOMATED FLAW DETECTION SCHEME FOR NDE X-RAY IMAGES GENERAL AUTOMATED FLAW DETECTION SCHEME FOR NDE X-RAY IMAGES Karl W. Ulmer and John P. Basart Center for Nondestructive Evaluation Department of Electrical and Computer Engineering Iowa State University

More information

Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field. Kouichi Inagaki ICC / IHI Corporation

Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field. Kouichi Inagaki ICC / IHI Corporation Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field Kouichi Inagaki ICC / IHI Corporation 13 th WORLD CONFERENCE ON INVESTMENT CASTING Paper: T3 Copyright

More information

Applying Hounsfield unit density calibration in SkyScan CT-analyser

Applying Hounsfield unit density calibration in SkyScan CT-analyser 1 Bruker-microCT Method note Applying Hounsfield unit density calibration in SkyScan CT-analyser Hounsfield units (HU) are a standard unit of x-ray CT density, in which air and water are ascribed values

More information

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications 4th International Symposium on NDT in Aerospace 2012 - Tu.3.A.1 Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications Malte KURFISS 1, Gerd STRECKENBACH 2 1 YXLON International

More information

RADIOLOGY AND DIAGNOSTIC IMAGING

RADIOLOGY AND DIAGNOSTIC IMAGING Day 2 part 2 RADIOLOGY AND DIAGNOSTIC IMAGING Dr hab. Zbigniew Serafin, MD, PhD serafin@cm.umk.pl 2 3 4 5 CT technique CT technique 6 CT system Kanal K: RSNA/AAPM web module: CT Systems & CT Image Quality

More information

ML reconstruction for CT

ML reconstruction for CT ML reconstruction for CT derivation of MLTR rigid motion correction resolution modeling polychromatic ML model dual energy ML model Bruno De Man, Katrien Van Slambrouck, Maarten Depypere, Frederik Maes,

More information

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS 23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN 16-20 APRIL 2007 HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS P. Helberg 1,

More information

Simulation of Beam Hardening in Industrial CT with x-ray and Monoenergetic Source by Monte Carlo Code

Simulation of Beam Hardening in Industrial CT with x-ray and Monoenergetic Source by Monte Carlo Code 2012, TextRoad Publication ISSN 2090-4304 Journal of Basic and Applied Scientific Research www.textroad.com Simulation of Beam Hardening in Industrial CT with x-ray and Monoenergetic Source by Monte Carlo

More information

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT More Info at Open Access Database www.ndt.net/?id=18754 Novel evaluation method of low contrast resolution performance of dimensional X-ray CT Makoto Abe 1, Hiroyuki Fujimoto 1, Osamu Sato 1, Kazuya Matsuzaki

More information

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste. 16648 Stephen Halliwell, VJ Technologies Inc, 89 Carlough Road, Bohemia, NY 11716, USA.

More information

Optiv CT160 Accurate measurement for every detail. Computed Tomography System

Optiv CT160 Accurate measurement for every detail. Computed Tomography System Optiv CT160 Accurate measurement for every detail Computed Tomography System Computed Tomography CT Technology. New prospects for metrology. Computed tomography (CT), a technology with unique advantages,

More information

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING Reveal pathology Reveal the anatomic truth Steven R. Singer, DDS srs2@columbia.edu IDEAL DIAGNOSTIC IMAGING STUDY Provides desired diagnostic

More information

Metal Artifact Reduction CT Techniques. Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland

Metal Artifact Reduction CT Techniques. Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland Metal Artifact Reduction CT Techniques R S S S Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland N. 1 v o 4 1 0 2. Postoperative CT Metal Implants CT is accurate for assessment

More information

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D. Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D. Applied Science Laboratory, GE Healthcare Technologies 1 Image Generation Reconstruction of images from projections. textbook reconstruction advanced

More information

A Curvelet based Sinogram Correction Method for Metal Artifact Reduction

A Curvelet based Sinogram Correction Method for Metal Artifact Reduction A based Sinogram Correction Method for Metal Artifact Reduction Kiwan Jeon 1 and Hyoung Suk Park 1 More info about this article: http://www.ndt.net/?id=3715 1 National Institute for Mathematical Sciences,

More information

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China 7th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Image Registration Combining Digital Radiography and Computer-Tomography Image Data Frank HEROLD YXLON International X-Ray

More information

System Optimization and Patient Translational Motion Correction for Reduction of Artifacts in a Fan-Beam CT Scanner

System Optimization and Patient Translational Motion Correction for Reduction of Artifacts in a Fan-Beam CT Scanner Wright State University CORE Scholar Browse all Theses and Dissertations Theses and Dissertations 2012 System Optimization and Patient Translational Motion Correction for Reduction of Artifacts in a Fan-Beam

More information

SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory

SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory Introduction In this lab exercise, you will investigate the linearity of the DeskCAT scanner by making measurements

More information

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system ECNDT 2014 Prague October 6-10, 2014 Dr. Eberhard Neuser Dr. Alexander Suppes Imagination

More information

Image Acquisition Systems

Image Acquisition Systems Image Acquisition Systems Goals and Terminology Conventional Radiography Axial Tomography Computer Axial Tomography (CAT) Magnetic Resonance Imaging (MRI) PET, SPECT Ultrasound Microscopy Imaging ITCS

More information

MEDICAL IMAGING 2nd Part Computed Tomography

MEDICAL IMAGING 2nd Part Computed Tomography MEDICAL IMAGING 2nd Part Computed Tomography Introduction 2 In the last 30 years X-ray Computed Tomography development produced a great change in the role of diagnostic imaging in medicine. In convetional

More information

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY Prof. Yasser Mostafa Kadah www.k-space.org Recommended Textbook X-Ray Computed Tomography in Biomedical Engineering, by Robert Cierniak, Springer, 211 Computed Tomography

More information

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0 Revised 10/10 COURSE SYLLABUS TM 220 COMPUTED TOMOGRAPHY PHYSICS CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0 CATALOG COURSE DESCRIPTION: This course is one of a three course set in whole body Computed

More information

A new calibration-free beam hardening reduction method for industrial CT

A new calibration-free beam hardening reduction method for industrial CT A new calibration-free beam hardening reduction method for industrial CT ECC 2 for industrial CT Tobias Würfl 1, Nicole Maaß 2, Frank Dennerlein 2, Andreas K. Maier 1 1 Pattern Recognition Lab, FAU Erlangen-Nürnberg;

More information

Enhanced material contrast by dual-energy microct imaging

Enhanced material contrast by dual-energy microct imaging Enhanced material contrast by dual-energy microct imaging Method note Page 1 of 12 2 Method note: Dual-energy microct analysis 1. Introduction 1.1. The basis for dual energy imaging Micro-computed tomography

More information

Advanced Computed Tomography System for the Inspection of Large Aluminium Car Bodies

Advanced Computed Tomography System for the Inspection of Large Aluminium Car Bodies ECNDT 2006 - Th.3.4.2 Advanced Computed Tomography System for the Inspection of Large Aluminium Car Bodies M. SIMON, I. TISEANU, C. SAUERWEIN Hans WÄLISCHMILLER, Meersburg, Germany M. SINDEL, M. BRODMANN,

More information

INDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY

INDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY INDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY VERIFICATION AND ANALYSIS M. L. Hsiao and J. W. Eberhard CR&D General Electric Company Schenectady, NY 12301 J. B. Ross Aircraft Engine - QTC General

More information

Comparison of Scatter Correction Methods for CBCT. Author(s): Suri, Roland E.; Virshup, Gary; Kaissl, Wolfgang; Zurkirchen, Luis

Comparison of Scatter Correction Methods for CBCT. Author(s): Suri, Roland E.; Virshup, Gary; Kaissl, Wolfgang; Zurkirchen, Luis Research Collection Working Paper Comparison of Scatter Correction Methods for CBCT Author(s): Suri, Roland E.; Virshup, Gary; Kaissl, Wolfgang; Zurkirchen, Luis Publication Date: 2010 Permanent Link:

More information

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA Computed Tomography Principles, Design, Artifacts, and Recent Advances THIRD EDITION Jiang Hsieh SPIE PRESS Bellingham, Washington USA Table of Contents Preface Nomenclature and Abbreviations xi xv 1 Introduction

More information

Digital Image Processing. Image Enhancement - Filtering

Digital Image Processing. Image Enhancement - Filtering Digital Image Processing Image Enhancement - Filtering Derivative Derivative is defined as a rate of change. Discrete Derivative Finite Distance Example Derivatives in 2-dimension Derivatives of Images

More information

Development of a multi-axis X-ray CT for highly accurate inspection of electronic devices

Development of a multi-axis X-ray CT for highly accurate inspection of electronic devices Development of a multi-axis X-ray CT for highly accurate inspection of electronic devices Toru Kano 1, Michihiko Koseki 2 More info about this article: http://www.ndt.net/?id=20843 1 Tokyo University of

More information

NDT OF SPECIMEN OF COMPLEX GEOMETRY USING ULTRASONIC ADAPTIVE

NDT OF SPECIMEN OF COMPLEX GEOMETRY USING ULTRASONIC ADAPTIVE NDT OF SPECIMEN OF COMPLEX GEOMETRY USING ULTRASONIC ADAPTIVE TECHNIQUES - THE F.A.U.S.T. SYSTEM INTRODUCTION O. Roy, S. Mahaut, M. Serre Commissariat a I'Energie Atomique CEAlCEREM, CE Saclay France Phased

More information

A method and algorithm for Tomographic Imaging of highly porous specimen using Low Frequency Acoustic/Ultrasonic signals

A method and algorithm for Tomographic Imaging of highly porous specimen using Low Frequency Acoustic/Ultrasonic signals More Info at Open Access Database www.ndt.net/?id=15210 A method and algorithm for Tomographic Imaging of highly porous specimen using Low Frequency Acoustic/Ultrasonic signals Subodh P S 1,a, Reghunathan

More information

An Iterative Approach to the Beam Hardening Correction in Cone Beam CT (Proceedings)

An Iterative Approach to the Beam Hardening Correction in Cone Beam CT (Proceedings) Marquette University e-publications@marquette Biomedical Engineering Faculty Research and Publications Engineering, College of 1-1-1999 An Iterative Approach to the Beam Hardening Correction in Cone Beam

More information

Industrial Computed Tomography Innovations

Industrial Computed Tomography Innovations GE Inspection Technologies Industrial Computed Tomography Innovations Premium performance for premium quality and speed. gemeasurement.com/ct Premium CT technologies. Faster than ever before. Every industrial

More information

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography Marc Kachelrieß, a Katia Sourbelle, and Willi A. Kalender Institute of Medical Physics, University of

More information

EE795: Computer Vision and Intelligent Systems

EE795: Computer Vision and Intelligent Systems EE795: Computer Vision and Intelligent Systems Spring 2012 TTh 17:30-18:45 WRI C225 Lecture 04 130131 http://www.ee.unlv.edu/~b1morris/ecg795/ 2 Outline Review Histogram Equalization Image Filtering Linear

More information

CALIBRATIONS FOR ANALYZING INDUSTRIAL SAMPLES ON MEDICAL CT SCANNERS

CALIBRATIONS FOR ANALYZING INDUSTRIAL SAMPLES ON MEDICAL CT SCANNERS CALIBRATIONS FOR ANALYZING INDUSTRIAL SAMPLES ON MEDICAL CT SCANNERS INTRODUCTION Patricia K. Hunt, Philip Engler, and William D. Friedman BP American Research and Development 4440 Warrensville Center

More information

NON-COLLIMATED SCATTERED RADIATION TOMOGRAPHY

NON-COLLIMATED SCATTERED RADIATION TOMOGRAPHY NON-COLLIMATED SCATTERED RADIATION TOMOGRAPHY Gorshkov V.A., Space Research Institute, Moscow, Russia Yumashev V.M., State corporation "Rosatom", Centre "Atom-innovation", Moscow, Russia Kirilenko K.V.,

More information

Porosity and Pore-Size Distribution of Geomaterials from X-Ray CT Scans

Porosity and Pore-Size Distribution of Geomaterials from X-Ray CT Scans Porosity and Pore-Size Distribution of Geomaterials from X-Ray CT Scans Hyu-Soung Shin & Kwang-Yeom Kim Geotechnical Eng. Research Division, Korea Institute of Construction Technology (KICT), South Korea

More information

J. Ling Chinese Academy of Science Institute for Ceramics Shanghai, China

J. Ling Chinese Academy of Science Institute for Ceramics Shanghai, China DEVELOPMENT AND APPLICATION OF LOCAL 3-D CT RECONSTRUCTION SOFTWARE FOR IMAGING CRITICAL REGIONS IN LARGE CERAMIC TURBINE ROTORS E. A. Sivers, D. L. Holloway, and W. A. Ellingson Argonne National Laboratory

More information

Multi-spectral (W, Mo, Cu, and Ag) XCT measurements

Multi-spectral (W, Mo, Cu, and Ag) XCT measurements Multi-spectral (W, Mo, Cu, and Ag) XCT measurements Marko Katić 1, Damir Markučič 1, Gorana Baršić 1 Faculty of mechanical engineering and naval architecture, Ivana Lucica 5, Zagreb, Croatia, marko.katic@fsb.hr

More information

Computer-Tomography II: Image reconstruction and applications

Computer-Tomography II: Image reconstruction and applications Computer-Tomography II: Image reconstruction and applications Prof. Dr. U. Oelfke DKFZ Heidelberg Department of Medical Physics (E040) Im Neuenheimer Feld 280 69120 Heidelberg, Germany u.oelfke@dkfz.de

More information

Refinement of Imaging Processing of Scatter Correction and Beam Hardening Tools for Industrial Radiography and Cone Beam CT

Refinement of Imaging Processing of Scatter Correction and Beam Hardening Tools for Industrial Radiography and Cone Beam CT Digital Industrial Radiology and Computed Tomography (DIR 2015) 22-25 June 2015, Belgium, Ghent - www.ndt.net/app.dir2015 More Info at Open Access Database www.ndt.net/?id=18073 Refinement of Imaging Processing

More information

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography Characterization of microshells experimented on Laser Megajoule using X-Ray tomography More info about this article: http://www.ndt.net/?id=20881 Alexandre Choux, Lise Barnouin, Ludovic Reverdy, Marc Theobald

More information

Image Processing

Image Processing Image Processing 159.731 Canny Edge Detection Report Syed Irfanullah, Azeezullah 00297844 Danh Anh Huynh 02136047 1 Canny Edge Detection INTRODUCTION Edges Edges characterize boundaries and are therefore

More information

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT Benedikt Lorch 1, Martin Berger 1,2, Joachim Hornegger 1,2, Andreas Maier 1,2 1 Pattern Recognition Lab, FAU Erlangen-Nürnberg

More information

Ultrasonic Multi-Skip Tomography for Pipe Inspection

Ultrasonic Multi-Skip Tomography for Pipe Inspection 18 th World Conference on Non destructive Testing, 16-2 April 212, Durban, South Africa Ultrasonic Multi-Skip Tomography for Pipe Inspection Arno VOLKER 1, Rik VOS 1 Alan HUNTER 1 1 TNO, Stieltjesweg 1,

More information

Image Restoration and Reconstruction

Image Restoration and Reconstruction Image Restoration and Reconstruction Image restoration Objective process to improve an image, as opposed to the subjective process of image enhancement Enhancement uses heuristics to improve the image

More information

Engineered Diffusers Intensity vs Irradiance

Engineered Diffusers Intensity vs Irradiance Engineered Diffusers Intensity vs Irradiance Engineered Diffusers are specified by their divergence angle and intensity profile. The divergence angle usually is given as the width of the intensity distribution

More information

Tomographic Reconstruction

Tomographic Reconstruction Tomographic Reconstruction 3D Image Processing Torsten Möller Reading Gonzales + Woods, Chapter 5.11 2 Overview Physics History Reconstruction basic idea Radon transform Fourier-Slice theorem (Parallel-beam)

More information

CoE4TN3 Medical Image Processing

CoE4TN3 Medical Image Processing CoE4TN3 Medical Image Processing Image Restoration Noise Image sensor might produce noise because of environmental conditions or quality of sensing elements. Interference in the image transmission channel.

More information

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH 3/27/212 Advantages of SPECT SPECT / CT Basic Principles Dr John C. Dickson, Principal Physicist UCLH Institute of Nuclear Medicine, University College London Hospitals and University College London john.dickson@uclh.nhs.uk

More information

Sizing and evaluation of planar defects based on Surface Diffracted Signal Loss technique by ultrasonic phased array

Sizing and evaluation of planar defects based on Surface Diffracted Signal Loss technique by ultrasonic phased array Sizing and evaluation of planar defects based on Surface Diffracted Signal Loss technique by ultrasonic phased array A. Golshani ekhlas¹, E. Ginzel², M. Sorouri³ ¹Pars Leading Inspection Co, Tehran, Iran,

More information

3D X-ray Laminography with CMOS Image Sensor Using a Projection Method for Reconstruction of Arbitrary Cross-sectional Images

3D X-ray Laminography with CMOS Image Sensor Using a Projection Method for Reconstruction of Arbitrary Cross-sectional Images Ke Engineering Materials Vols. 270-273 (2004) pp. 192-197 online at http://www.scientific.net (2004) Trans Tech Publications, Switzerland Online available since 2004/08/15 Citation & Copright (to be inserted

More information

Advanced Image Reconstruction Methods for Photoacoustic Tomography

Advanced Image Reconstruction Methods for Photoacoustic Tomography Advanced Image Reconstruction Methods for Photoacoustic Tomography Mark A. Anastasio, Kun Wang, and Robert Schoonover Department of Biomedical Engineering Washington University in St. Louis 1 Outline Photoacoustic/thermoacoustic

More information

Shielding factors for traditional safety glasses

Shielding factors for traditional safety glasses Shielding factors for traditional safety glasses Malcolm McEwen, Hong Shen and Ernesto Mainegra-Hing Ionizing Radiation Standards, National Research Council Canada Alan DuSautoy, Radiation and Health Sciences

More information

John R. Mandeville Senior Consultant NDICS, Norwich, CT Jesse A. Skramstad President - NDT Solutions Inc., New Richmond, WI

John R. Mandeville Senior Consultant NDICS, Norwich, CT Jesse A. Skramstad President - NDT Solutions Inc., New Richmond, WI Enhanced Defect Detection on Aircraft Structures Automatic Flaw Classification Software (AFCS) John R. Mandeville Senior Consultant NDICS, Norwich, CT Jesse A. Skramstad President - NDT Solutions Inc.,

More information

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago Optimization of CT Simulation Imaging Ingrid Reiser Dept. of Radiology The University of Chicago Optimization of CT imaging Goal: Achieve image quality that allows to perform the task at hand (diagnostic

More information

arxiv: v2 [cond-mat.mtrl-sci] 5 Jan 2010

arxiv: v2 [cond-mat.mtrl-sci] 5 Jan 2010 Gamma scattering scanning of concrete block for detection of voids. Shivaramu 1, Arijit Bose 2 and M. Margret 1 1 Radiological Safety Division, Safety Group, IGCAR, Kalpakaam - 63 12 (India) 2 Chennai

More information

Wieblinger Weg 92a, Heidelberg, Germany, Phone: , Fax: ;

Wieblinger Weg 92a, Heidelberg, Germany, Phone: , Fax: ; HOW INDUSTRIAL COMPUTER TOMOGRAPHY ACCELERATES PRODUCT DEVELOPMENT IN THE LIGHT METAL CASTING AND INJECTION MOULDING INDUSTRY. Christof REINHART 1, Christoph POLIWODA 1, Thomas GÜNTHER 1 1 Volume Graphics

More information

A THREE-DIMENSIONAL PHASED ARRAY ULTRASONIC TESTING TECHNIQUE

A THREE-DIMENSIONAL PHASED ARRAY ULTRASONIC TESTING TECHNIQUE A THREE-DIMENSIONAL PHASED ARRAY ULTRASONIC TESTING TECHNIQUE So KITAZAWA, Naoyuki KONO, Atsushi BABA and Yuji ADACHI HITACHI, Ltd., Japan Mitsuru ODAKURA HITACHI-GE Nuclear Energy, Ltd., Japan Introduction

More information

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape Tasuku Ito 1, Yutaka Ohtake 1, Yukie Nagai 2, Hiromasa Suzuki 1 More info about this article: http://www.ndt.net/?id=23662

More information

Fundamentals of CT imaging

Fundamentals of CT imaging SECTION 1 Fundamentals of CT imaging I History In the early 1970s Sir Godfrey Hounsfield s research produced the first clinically useful CT scans. Original scanners took approximately 6 minutes to perform

More information

The new generation of industrial computed tomography. The Desktop CT exact S

The new generation of industrial computed tomography. The Desktop CT exact S The new generation of industrial computed tomography The Desktop CT S Volume scanning technology Innovation with a family tradition Founded in 1968, the family-owned, WEN- ZEL Metrology Group is one of

More information

45 µm polystyrene bead embedded in scattering tissue phantom. (a,b) raw images under oblique

45 µm polystyrene bead embedded in scattering tissue phantom. (a,b) raw images under oblique Phase gradient microscopy in thick tissue with oblique back-illumination Tim N Ford, Kengyeh K Chu & Jerome Mertz Supplementary Figure 1: Comparison of added versus subtracted raw OBM images 45 µm polystyrene

More information

Performance Evaluation of 3-Axis Scanner Automated For Industrial Gamma- Ray Computed Tomography

Performance Evaluation of 3-Axis Scanner Automated For Industrial Gamma- Ray Computed Tomography National Seminar & Exhibition on Non-Destructive Evaluation, NDE 2014, Pune, December 4-6, 2014 (NDE-India 2014) Vol.20 No.6 (June 2015) - The e-journal of Nondestructive Testing - ISSN 1435-4934 www.ndt.net/?id=17822

More information