Basics of treatment planning II
|
|
- Buck Hubbard
- 5 years ago
- Views:
Transcription
1 Basics of treatment planning II Sastry Vedam PhD DABR Introduction to Medical Physics III: Therapy Spring 2015 Dose calculation algorithms! Correction based! Model based 1
2 Dose calculation algorithms! Representation of patient and dose distribution! Block of tissue of uniform density! Contour external surface with solder wire! Contours obtained from CT Dose calculation algorithms! Modern algorithms! 3D point by point/voxel by voxel description of patient (CT)! Spatial reliability of CT (<2%)! Dose uncertainty (photon beams) <1%! Typical CT scan! images! mm slice thickness! 512x512 pixels per imaging plane! 2-16 bytes to store HU value data 2
3 Dose calculation algorithms! Speed! Processor power! Grid spacing! Non uniform sample spacing within grid! Calculation algorithm Correction based algorithms 3
4 Dose calculation algorithms! Correction based! Semi empirical! Based on measured data (PDD, Profiles etc.,)! Reference calibration condition! a defined location in water phantom for a defined field size! Corrections for:! Attenuation! Contour irregularity! Beam modifiers! Tissue inhomogeneities! Scatter (Scattering volume, field size, shape and radial distance)! Geometry (Non reference SSD/depth) MU Isocentric setup 4
5 MU Non Isocentric setup Correction based algorithms! Limited accuracy! 3D heterogeneity corrections at tissue interfaces! Lack of complete electronic equilibrium! Secondary check for MUs calculated from more complex model based algorithms 5
6 Model based algorithms Model based algorithms! Compute dose distribution with a physical model that actually simulates radiation transport through a patient! Radiation transport! Production of megavoltage X-rays in treatment head! Interaction and scattering of photons by Compton Effect! Effects of transport of charged particles near boundaries and tissue heterogeneities 6
7 Radiation Transport Electron disequilibrium due to greater lateral range of electrons compared to field size Radiation Transport Pencil beam charge particle tracks in phantom 7
8 Convolution Convolution Energy fluence Energy deposition kernel (Patient density map) Dose 8
9 Convolution/Superposition! Several variations! Common/essential components! Energy imparted to medium by interactions of primary photons (TERMA)! Energy deposited about a primary interaction site (Kernel)! Kernel! Primary (Primary dose)! First and multiple scatter dose (Can be calculated together or separately)! Kernel also referred to as:! Dose spread array! Differential pencil beam! Point spread function! Energy deposition kernel TERMA! Total energy released per unit mass! Energy imparted to secondary charged particles! Energy retained by scattered photon! Sum of the above should equal energy of the primary photon for each interaction TERMA Mass attenuation coefficient Energy fluence 9
10 TERMA! Poly energetic nature! Attenuation map for each energy and each depth r from surface! Divergent beam (Inverse square fall off)! Inhomogeneity correction (Geometric vs Radiological depth) TERMA! 3D voxel array with TERMA values is obtained before convolution! Involves:! Array of electron densities from CT slices! Calculating radiological depth for each of the voxels! Calculating TERMA for each voxel 10
11 Convolution Process! Dose at each point in medium! Primary photon interactions throughout the irradiated volume! Summing dose contributions from each voxel TERMA Primary energy deposition kernel Scatter energy deposition kernel Convolution Process! Convolution can be done by either:! Integrating dose deposited at successive points due to TERMA throughout the medium (Deposition point of view)! Calculating dose contribution throughout the medium due to TERMA at successive interaction points (Interaction point of view) TERMA Primary energy deposition kernel Scatter energy deposition kernel 11
12 Convolution process Deposition point of view Interaction point of view Convolution process! Deposition point of view! Best if dose is calculated only in a subset of the irradiated volume! TERMA in each voxel must be stored in an array! Interaction point of view! Only a single TERMA value needs to be stored at any time 12
13 Fourier transform Convolution process: The Fourier Transform! Assuming the kernels are spatially invariant, if the convolution of TERMA with a kernel to obtain dose can be written as,! Fourier transform of the dose is given by, 13
14 Convolution in Inhomogeneous medium! Kernels are functions of displacement only! In Inhomogeneous media, the fractional energy contribution will depend on both distance between interaction site and deposition site as well as densities at interaction and deposition sites Convolution in Inhomogeneous medium! First approximation! Energy loss by secondary electrons dependent on effective path length (average density through ray tracing)! Incorrect for primary kernel! Electron scattering! No and energy of electrons depends not only on avg density but also on density distribution! Good for scatter kernel! Fluence of onee-scattered photons is proportional to average density! Range of electrons ejected by these photons is very small 14
15 Convolution in Inhomogeneous medium! Since rate of energy deposition in each voxel is proportional to the density within voxel, kernel value can be obtained by! Substituting into the equation for dose, Variations of convolution! Original Real-Space Convolution (Mackie et al, 1985)! Kernels separated into primary, truncated first scatter (TFS) and residual first and multiple scatter (RFMS) arrays! TFS First scatter dose, relatively close to the interaction site! RFMS Multiple scatter and first scatter not included in TFS! Scatter separation allowed for smaller higher resolution kernel arrays! Average density scaling for a range of densities between interaction and deposition sites for primary and TFS! Avg density of phantom in kernel scaling for RFMS 15
16 Variations of convolution! Differential pencil beam method (Mohan et al, 1986, Ahnesjo et al., 1987)! Infinitesimal segment of a pencil beam! Equivalent to a convolution kernel except,! Dose deposited in water per unit primary photon collision density, instead of per unit energy imparted by primary photons Variations of convolution! Collapsed cone convolution (Ahnesjo et al., 1989)! Polyenergetic TERMA and kernel! Kernel represented analytically and combines primary and scatter contributions! Functions used to characterize kernel are, 16
17 Variations of convolution! Collapsed cone convolution (Ahnesjo et al., 1989)! Finite number of polar angles w.r.t. primary beam along which the function is defined! Interaction site apex of a set of radially directed lines spreading out in 3D! Each line is further considered the axis of a cone! Kernel function along each line energy deposited within the entire cone at radius r collapsed onto the line! TERMA is calculated and represented in a cartesian array! Inhomogeneities are accounted for in TERMA array! Reduced computation time when compared to conventional convolution 17
Basics of treatment planning II
Basics of treatment planning II Sastry Vedam PhD DABR Introduction to Medical Physics III: Therapy Spring 2015 Monte Carlo Methods 1 Monte Carlo! Most accurate at predicting dose distributions! Based on
More informationELECTRON DOSE KERNELS TO ACCOUNT FOR SECONDARY PARTICLE TRANSPORT IN DETERMINISTIC SIMULATIONS
Computational Medical Physics Working Group Workshop II, Sep 30 Oct 3, 2007 University of Florida (UF), Gainesville, Florida USA on CD-ROM, American Nuclear Society, LaGrange Park, IL (2007) ELECTRON DOSE
More informationBasic Radiation Oncology Physics
Basic Radiation Oncology Physics T. Ganesh, Ph.D., DABR Chief Medical Physicist Fortis Memorial Research Institute Gurgaon Acknowledgment: I gratefully acknowledge the IAEA resources of teaching slides
More informationTransitioning from pencil beam to Monte Carlo for electron dose calculations
Transitioning from pencil beam to Monte Carlo for electron dose calculations Jessie Huang-Vredevoogd (jyhuang4@wisc.edu) University of Wisconsin NCC AAPM October 12, 2019 1 Topics to cover Background RayStation
More informationElectron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations
Electron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations A. Al-Basheer, G. Sjoden, M. Ghita Computational Medical Physics Team Nuclear & Radiological Engineering University
More informationProton dose calculation algorithms and configuration data
Proton dose calculation algorithms and configuration data Barbara Schaffner PTCOG 46 Educational workshop in Wanjie, 20. May 2007 VARIAN Medical Systems Agenda Broad beam algorithms Concept of pencil beam
More informationA SYSTEM OF DOSIMETRIC CALCULATIONS
A SYSTEM OF DOSIMETRIC CALCULATIONS INTRODUCTION Dose calculation based on PDD and TAR have Limitations The dependence of PDD on SSD Not suitable for isocentric techniques TAR and SAR does not depend on
More informationGPU Based Convolution/Superposition Dose Calculation
GPU Based Convolution/Superposition Dose Calculation Todd McNutt 1, Robert Jacques 1,2, Stefan Pencea 2, Sharon Dye 2, Michel Moreau 2 1) Johns Hopkins University 2) Elekta Research Funded by and Licensed
More informationRelease Notes for Dosimetry Check with Convolution-Superposition Collapsed Cone Algorithm (CC)
Dosimetry Check for convolution/superposition collapsed cone (CC), Page 1 of 11 Release Notes for Dosimetry Check with Convolution-Superposition Collapsed Cone Algorithm (CC) File: CCReleaseNotes.doc Date:
More informationMonte Carlo methods in proton beam radiation therapy. Harald Paganetti
Monte Carlo methods in proton beam radiation therapy Harald Paganetti Introduction: Proton Physics Electromagnetic energy loss of protons Distal distribution Dose [%] 120 100 80 60 40 p e p Ionization
More informationPhoton beam dose distributions in 2D
Photon beam dose distributions in 2D Sastry Vedam PhD DABR Introduction to Medical Physics III: Therapy Spring 2014 Acknowledgments! Narayan Sahoo PhD! Richard G Lane (Late) PhD 1 Overview! Evaluation
More informationIntroduction to Biomedical Imaging
Alejandro Frangi, PhD Computational Imaging Lab Department of Information & Communication Technology Pompeu Fabra University www.cilab.upf.edu X-ray Projection Imaging Computed Tomography Digital X-ray
More informationPhoton Dose Algorithms and Physics Data Modeling in modern RTP
Photon Dose Algorithms and Physics Data Modeling in modern RTP Niko Papanikolaou, PhD Professor and Director of Medical Physics University of Texas Health Science Center of San Antonio Cancer Therapy &
More information15 Dose Calculation Algorithms
Dose Calculation Algorithms 187 15 Dose Calculation Algorithms Uwe Oelfke and Christian Scholz CONTENTS 15.1 Introduction 187 15.2 Model-Based Algorithms 188 15.3 Modeling of the Primary Photon Fluence
More informationAccuracy of treatment planning calculations for conformal radiotherapy van 't Veld, Aart Adeodatus
University of Groningen Accuracy of treatment planning calculations for conformal radiotherapy van 't Veld, Aart Adeodatus IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's
More informationCalculation algorithms in radiation therapy treatment planning systems
Calculation algorithms in radiation therapy treatment planning systems Colleen DesRosiers, Ph.D. AAMD Region III annual meeting, Indianapolis, Indiana April 12, 2013 Learning Objectives 1. The learner
More informationMonitor Unit (MU) Calculation
Monitor Unit (MU) Calculation Timothy C. Zhu 1, Haibo Lin 1, and JiaJian Shen 2 1 University of Pennsylvania, Philadelphia, PA 2 Mayo Clinic, Phoenix, AZ Introduction Pencil-beam based dose/mu algorithms
More informationCh. 4 Physical Principles of CT
Ch. 4 Physical Principles of CT CLRS 408: Intro to CT Department of Radiation Sciences Review: Why CT? Solution for radiography/tomography limitations Superimposition of structures Distinguishing between
More informationDose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them
Dose Distributions George Starkschall, Ph.D. Department of Radiation Physics U.T. M.D. Anderson Cancer Center Purpose To familiarize the resident with dose distributions and the factors that affect them
More informationEXTERNAL PHOTON BEAMS: PHYSICAL ASPECTS
EXTERNAL PHOTON BEAMS: PHYSICAL ASPECTS E.B. PODGORSAK Department of Medical Physics, McGill University Health Centre, Montreal, Quebec, Canada 6.1. INTRODUCTION Radiotherapy procedures fall into two main
More informationCentral Slice Theorem
Central Slice Theorem Incident X-rays y f(x,y) R x r x Detected p(, x ) The thick line is described by xcos +ysin =R Properties of Fourier Transform F [ f ( x a)] F [ f ( x)] e j 2 a Spatial Domain Spatial
More informationInvestigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers
Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers Krista Chytyk MSc student Supervisor: Dr. Boyd McCurdy Introduction The objective of cancer radiotherapy
More informationEffects of the difference in tube voltage of the CT scanner on. dose calculation
Effects of the difference in tube voltage of the CT scanner on dose calculation Dong Joo Rhee, Sung-woo Kim, Dong Hyeok Jeong Medical and Radiological Physics Laboratory, Dongnam Institute of Radiological
More informationDose Calculations: Where and How to Calculate Dose. Allen Holder Trinity University.
Dose Calculations: Where and How to Calculate Dose Trinity University www.trinity.edu/aholder R. Acosta, W. Brick, A. Hanna, D. Lara, G. McQuilen, D. Nevin, P. Uhlig and B. Slater Dose Calculations - Why
More informationgpmc: GPU-Based Monte Carlo Dose Calculation for Proton Radiotherapy Xun Jia 8/7/2013
gpmc: GPU-Based Monte Carlo Dose Calculation for Proton Radiotherapy Xun Jia xunjia@ucsd.edu 8/7/2013 gpmc project Proton therapy dose calculation Pencil beam method Monte Carlo method gpmc project Started
More informationSYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory
SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory Introduction In this lab exercise, you will investigate the linearity of the DeskCAT scanner by making measurements
More informationInfluence of electron density spatial distribution and X-ray beam quality during CT simulation on dose calculation accuracy
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 12, NUMBER 3, summer 2011 Influence of electron density spatial distribution and X-ray beam quality during CT simulation on dose calculation accuracy
More informationDosimetry Simulations with the UF-B Series Phantoms using the PENTRAN-MP Code System
Dosimetry Simulations with the UF-B Series Phantoms using the PENTRAN-MP Code System A. Al-Basheer, M. Ghita, G. Sjoden, W. Bolch, C. Lee, and the ALRADS Group Computational Medical Physics Team Nuclear
More informationAn Investigation of a Model of Percentage Depth Dose for Irregularly Shaped Fields
Int. J. Cancer (Radiat. Oncol. Invest): 96, 140 145 (2001) 2001 Wiley-Liss, Inc. Publication of the International Union Against Cancer An Investigation of a Model of Percentage Depth Dose for Irregularly
More informationLoma Linda University Medical Center Dept. of Radiation Medicine
Loma Linda University Medical Center Dept. of Radiation Medicine and Northern Illinois University Dept. of Physics and Dept. of Computer Science Presented by George Coutrakon, PhD NIU Physics Dept. Collaborators
More informationAnalysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code
American Journal of Biomedical Engineering 216, 6(4): 124-131 DOI: 1.5923/j.ajbe.21664.3 Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code Ankit Kajaria 1,*, Neeraj Sharma
More informationVerification of dose calculations with a clinical treatment planning system based on a point kernel dose engine
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 3, NUMBER 2, SPRING 2002 Verification of dose calculations with a clinical treatment planning system based on a point kernel dose engine Lars Weber*
More informationCOMPARISON OF DOSE CALCULATION ALGORITHMS FOR LEKSELL GAMMA KNIFE PERFEXION USING MONTE CARLO VOXEL PHANTOMS
COMPARISON OF DOSE CALCULATION ALGORITHMS FOR LEKSELL GAMMA KNIFE PERFEXION USING MONTE CARLO VOXEL PHANTOMS Jan Pipek 1, Josef Novotný Jr. 1,2,3, Josef Novotný 1, Petra Kozubíková 1 1 Faculty of Nuclear
More informationREAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT
REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT Anand P Santhanam Assistant Professor, Department of Radiation Oncology OUTLINE Adaptive radiotherapy for head and
More informationAutomated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator
Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator Andrew J Reilly Imaging Physicist Oncology Physics Edinburgh Cancer Centre Western General Hospital EDINBURGH EH4
More informationMichael Speiser, Ph.D.
IMPROVED CT-BASED VOXEL PHANTOM GENERATION FOR MCNP MONTE CARLO Michael Speiser, Ph.D. Department of Radiation Oncology UT Southwestern Medical Center Dallas, TX September 1 st, 2012 CMPWG Workshop Medical
More informationAdvantages of multiple algorithm support in treatment planning system for external beam dose calculations
Review Article Free full text available from www.cancerjournal.net Advantages of multiple algorithm support in treatment planning system for external beam dose calculations Animesh Kirloskar Theratronics
More information3D DETERMINISTIC RADIATION TRANSPORT FOR DOSE COMPUTATIONS IN CLINICAL PROCEDURES
3D DETERMINISTIC RADIATION TRANSPORT FOR DOSE COMPUTATIONS IN CLINICAL PROCEDURES By AHMAD AL-BASHEER A DISSERTATION PRESENTED TO THE GRADUATE SCHOOL OF THE UNIVERSITY OF FLORIDA IN PARTIAL FULFILLMENT
More informationDigital Scatter Removal in Mammography to enable Patient Dose Reduction
Digital Scatter Removal in Mammography to enable Patient Dose Reduction Mary Cocker Radiation Physics and Protection Oxford University Hospitals NHS Trust Chris Tromans, Mike Brady University of Oxford
More informationDigital Image Processing
Digital Image Processing SPECIAL TOPICS CT IMAGES Hamid R. Rabiee Fall 2015 What is an image? 2 Are images only about visual concepts? We ve already seen that there are other kinds of image. In this lecture
More informationTomographic Reconstruction
Tomographic Reconstruction 3D Image Processing Torsten Möller Reading Gonzales + Woods, Chapter 5.11 2 Overview Physics History Reconstruction basic idea Radon transform Fourier-Slice theorem (Parallel-beam)
More informationMonte Carlo simulations
MC simulations Monte Carlo simulations Eirik Malinen Simulations of stochastic processes Interactions are stochastic: the path of a single ioniing particle may not be predicted Interactions are quantified
More informationDUAL energy X-ray radiography [1] can be used to separate
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 53, NO. 1, FEBRUARY 2006 133 A Scatter Correction Using Thickness Iteration in Dual-Energy Radiography S. K. Ahn, G. Cho, and H. Jeon Abstract In dual-energy
More informationI Introduction 2. IV Relative dose in electron and photon beams 26 IV.A Dose and kerma per unit incident fluence... 27
Notes on the structure of radiotherapy depth-dose distributions David W O Rogers Carleton Laboratory for Radiotherapy Physics Physics Department, Carleton University, Ottawa, Canada drogers at physics.carleton.ca
More informationVoxel phantoms and Monte Carlo methods applied to internal and external dose calculations.
Voxel phantoms and Monte Carlo methods applied to internal and external dose calculations. J.G.Hunt, E.G. Cavalcanti, D.S. dos Santos e A.M.G. Azeredo. Instituto de Radioproteção e Dosimetria IRD/CNEN
More informationS. Guru Prasad, Ph.D., DABR
PURPOSE S. Guru Prasad, Ph.D., DABR Director of Medical Physics IAEA Consultant NorthShore University Health System and University of Chicago, Pritzker School of Medicine Current TPS utilize more information
More informationIMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE
QA SOFTWARE FAST, PRECISE Software for accurate and independent verification of monitor units, dose, and overall validity of standard, IMRT, VMAT, SRS and brachytherapy plans no film, no phantoms, no linac
More informationEngineered Diffusers Intensity vs Irradiance
Engineered Diffusers Intensity vs Irradiance Engineered Diffusers are specified by their divergence angle and intensity profile. The divergence angle usually is given as the width of the intensity distribution
More informationSpectral analysis of non-stationary CT noise
Spectral analysis of non-stationary CT noise Kenneth M. Hanson Los Alamos Scientific Laboratory Int. Symposium and Course on Computed Tomography, Las Vegas, April 7-11, 1980 This presentation available
More informationA dedicated tool for PET scanner simulations using FLUKA
A dedicated tool for PET scanner simulations using FLUKA P. G. Ortega FLUKA meeting June 2013 1 Need for in-vivo treatment monitoring Particles: The good thing is that they stop... Tumour Normal tissue/organ
More informationDose Calculation and Optimization Algorithms: A Clinical Perspective
Dose Calculation and Optimization Algorithms: A Clinical Perspective Daryl P. Nazareth, PhD Roswell Park Cancer Institute, Buffalo, NY T. Rock Mackie, PhD University of Wisconsin-Madison David Shepard,
More informationGPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC
GPU applications in Cancer Radiation Therapy at UCSD Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC Conventional Radiotherapy SIMULATION: Construciton, Dij Days PLANNING:
More informationArtifact Mitigation in High Energy CT via Monte Carlo Simulation
PIERS ONLINE, VOL. 7, NO. 8, 11 791 Artifact Mitigation in High Energy CT via Monte Carlo Simulation Xuemin Jin and Robert Y. Levine Spectral Sciences, Inc., USA Abstract The high energy (< 15 MeV) incident
More informationCT vs. VolumeScope: image quality and dose comparison
CT vs. VolumeScope: image quality and dose comparison V.N. Vasiliev *a, A.F. Gamaliy **b, M.Yu. Zaytsev b, K.V. Zaytseva ***b a Russian Sci. Center of Roentgenology & Radiology, 86, Profsoyuznaya, Moscow,
More information10 MV x - ray scatter dose - spread kernel construction using the Bjarngard scatter
10 MV x - ray scatter dose - spread kernel construction using the Bjarngard scatter factor expression Akira Iwasaki School of Allied Medical Sciences, Hirosaki University Research Code No.: 203 Key words:
More informationMonte Carlo simulations. Lesson FYSKJM4710 Eirik Malinen
Monte Carlo simulations Lesson FYSKJM4710 Eirik Malinen MC simulations 1 Simulations of stochastic processes Interactions are stochastic: the path of a single ionizing particle may not be predicted Interactions
More informationComparison of internal and external dose conversion factors using ICRP adult male and MEET Man voxel model phantoms.
Comparison of internal and external dose conversion factors using ICRP adult male and MEET Man voxel model phantoms. D.Leone, A.Häußler Intitute for Nuclear Waste Disposal, Karlsruhe Institute for Technology,
More informationDesign and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon
Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon WHITE PAPER Introduction Introducing an image guidance system based on Cone Beam CT (CBCT) and a mask immobilization
More informationDOSE-CALCULATION ALGORITHMS USED IN RADIATION TREATMENT PLANNING MANUEL SALGADO FERNÁNDEZ
Hospital do Meixoeiro DOSE-CALCULATION ALGORITHMS USED IN RADIATION TREATMENT PLANNING MANUEL SALGADO FERNÁNDEZ Servicio de Radíofísica y Protección Radiológica Galaria. Hospital do Meixoeiro. Av. Meixoeiro
More informationMachine and Physics Data Guide
WWW..COM Machine and Physics Data Guide STANDARD IMAGING, INC. 3120 Deming Way Middleton, WI 53562-1461 May / 2008 2008 Standard Imaging, Inc. TEL 800.261.4446 TEL 608.831.0025 FAX 608.831.2202 www.standardimaging.com
More informationAssesing multileaf collimator effect on the build-up region using Monte Carlo method
Pol J Med Phys Eng. 2008;14(3):163-182. PL ISSN 1425-4689 doi: 10.2478/v10013-008-0014-0 website: http://www.pjmpe.waw.pl M. Zarza Moreno 1, 2, N. Teixeira 3, 4, A. P. Jesus 1, 2, G. Mora 1 Assesing multileaf
More informationEvaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT
Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT Qiao Yang 1,4, Meng Wu 2, Andreas Maier 1,3,4, Joachim Hornegger 1,3,4, Rebecca Fahrig
More informationComparison of Predictions by MCNP and EGSnrc of Radiation Dose
Comparison of Predictions by MCNP and EGSnrc of Radiation Dose Computational Medical Physics Working Group Workshop II, Sep 30 Oct 3, 2007 at UF imparted to various Material Targets by Beams and small
More information2D DOSE MEASUREMENT USING A FLAT PANEL EPID
2D DOSE MEASUREMENT USING A FLAT PANEL EPID by Seng Boh Lim B.A.Sc. (Hons.), University of British Columbia, 1994 M.A.Sc., University of British Colombia, 1996 M.Eng, University of British Columbia, 2002
More informationMEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah
MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY Prof. Yasser Mostafa Kadah www.k-space.org Recommended Textbook X-Ray Computed Tomography in Biomedical Engineering, by Robert Cierniak, Springer, 211 Computed Tomography
More informationMEDICAL IMAGING 2nd Part Computed Tomography
MEDICAL IMAGING 2nd Part Computed Tomography Introduction 2 In the last 30 years X-ray Computed Tomography development produced a great change in the role of diagnostic imaging in medicine. In convetional
More informationC a t p h a n / T h e P h a n t o m L a b o r a t o r y
C a t p h a n 5 0 0 / 6 0 0 T h e P h a n t o m L a b o r a t o r y C a t p h a n 5 0 0 / 6 0 0 Internationally recognized for measuring the maximum obtainable performance of axial, spiral and multi-slice
More informationHidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept.
2-D D Dose-CT Mapping in Geant4 Hidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept. Table of Contents Background & Purpose Materials Methods
More informationNew Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC
New Technology in Radiation Oncology James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC Technology s s everywhere From the imaging chain To the planning system To the linac To QA..it..it
More informationTomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS
Tomotherapy Physics Machine Twinning and Quality Assurance Emilie Soisson, MS Tomotherapy at UW- Madison Treating for nearly 5 years Up to ~45 patients a day on 2 tomo units Units twinned to facilitate
More informationVALIDATION OF A MONTE CARLO DOSE CALCULATION ALGORITHM FOR CLINICAL ELECTRON BEAMS IN THE PRESENCE OF PHANTOMS WITH COMPLEX HETEROGENEITIES
VALIDATION OF A MONTE CARLO DOSE CALCULATION ALGORITHM FOR CLINICAL ELECTRON BEAMS IN THE PRESENCE OF PHANTOMS WITH COMPLEX HETEROGENEITIES by Shayla Landfair Enright A Thesis Submitted to the Faculty
More informationImage-based Monte Carlo calculations for dosimetry
Image-based Monte Carlo calculations for dosimetry Irène Buvat Imagerie et Modélisation en Neurobiologie et Cancérologie UMR 8165 CNRS Universités Paris 7 et Paris 11 Orsay, France buvat@imnc.in2p3.fr
More informationGeant4 in Brachytherapy
Geant4 in Brachytherapy 1. 2. 3. 4. 5. Brachytherapy: Brief Overview Clinical applications Basic research Ultrafast & biology applications Issues for the work group 1 Brachytherapy: Overview Brachy: Greek
More informationVCU Radiation Oncology
Semi-empirical Dose-Calculation Models in Brachytherapy AAPM 2005 Summer School 25 July 2004 Jeffrey F. Williamson, Ph.D. VCU Radiation Oncology Virginia Commonwealth University Semi-Empirical Dose-Calculation
More informationIterative regularization in intensity-modulated radiation therapy optimization. Carlsson, F. and Forsgren, A. Med. Phys. 33 (1), January 2006.
Iterative regularization in intensity-modulated radiation therapy optimization Carlsson, F. and Forsgren, A. Med. Phys. 33 (1), January 2006. 2 / 15 Plan 1 2 3 4 3 / 15 to paper The purpose of the paper
More informationSpiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA
Spiral CT Protocol Optimization & Quality Assurance Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA Spiral CT Protocol Optimization & Quality Assurance Protocol optimization
More informationMedical Image Reconstruction Term II 2012 Topic 6: Tomography
Medical Image Reconstruction Term II 2012 Topic 6: Tomography Professor Yasser Mostafa Kadah Tomography The Greek word tomos means a section, a slice, or a cut. Tomography is the process of imaging a cross
More informationComparison of absorbed dose distribution 10 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm
Journal of Physics: Conference Series PAPER OPEN ACCESS Comparison of absorbed dose distribution 1 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm To cite
More informationIntroduction to Medical Imaging. Cone-Beam CT. Klaus Mueller. Computer Science Department Stony Brook University
Introduction to Medical Imaging Cone-Beam CT Klaus Mueller Computer Science Department Stony Brook University Introduction Available cone-beam reconstruction methods: exact approximate algebraic Our discussion:
More informationImplementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43
International Journal of Innovation and Applied Studies ISSN 2028-9324 Vol. 6 No. 3 July 2014, pp. 635-641 2014 Innovative Space of Scientific Research Journals http://www.ijias.issr-journals.org/ Implementation
More informationDevelopment a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code
Iran. J. Radiat. Res., 2006; 4 (1): 7-14 Development a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code. Mesbahi * Department of Medical Physics, Medical School,
More informationINTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory
INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1 Modifications for P551 Fall 2013 Medical Physics Laboratory Introduction Following the introductory lab 0, this lab exercise the student through
More informationADVANCING CANCER TREATMENT
3 ADVANCING CANCER TREATMENT SUPPORTING CLINICS WORLDWIDE RaySearch is advancing cancer treatment through pioneering software. We believe software has un limited potential, and that it is now the driving
More informationAn Automated Image-based Method for Multi-Leaf Collimator Positioning Verification in Intensity Modulated Radiation Therapy
An Automated Image-based Method for Multi-Leaf Collimator Positioning Verification in Intensity Modulated Radiation Therapy Chenyang Xu 1, Siemens Corporate Research, Inc., Princeton, NJ, USA Xiaolei Huang,
More informationSlide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.
Slide 1 Technical Aspects of Quality Control in Magnetic Resonance Imaging Slide 2 Compliance Testing of MRI Systems, Ph.D. Department of Radiology Henry Ford Hospital, Detroit, MI Slide 3 Compliance Testing
More informationRecognition and Measurement of Small Defects in ICT Testing
19 th World Conference on Non-Destructive Testing 2016 Recognition and Measurement of Small Defects in ICT Testing Guo ZHIMIN, Ni PEIJUN, Zhang WEIGUO, Qi ZICHENG Inner Mongolia Metallic Materials Research
More informationCode characteristics
The PENELOPE Computer code M.J. Anagnostakis Nuclear Engineering Department National Technical University of Athens The PENELOPE code system PENetration and Energy LOss of Positrons and Electrons in matter
More informationUNCOMPROMISING QUALITY
ION CHAMBERS UNCOMPROMISING QUALITY Designed with over 30 years of scientific integrity for a broad range of dosimetry measurements in diverse radiation beams Farmer-type Chambers For absolute dosimetry
More informationPCRT 3D. Scalable Architecture System. User-Friendly. Traceable. Continuos Development
PCRT 3D The PCRT3D is a versatile 3D radiation treatment planning system featuring the most accurate algorithm calculations, the latest techniques in virtual simulation and the most advanced radiotherapy
More informationA prototype table-top inverse-geometry volumetric CT system
A prototype table-top inverse-geometry volumetric CT system Taly Gilat Schmidt a Department of Radiology, Stanford University, Stanford, California 94305 Josh Star-Lack NexRay, Inc., Los Gatos, California
More informationDose Calculation and Verification for Tomotherapy
Dose Calculation and Verification for Tomotherapy John P. Gibbons, PhD Chief of Clinical Physics Mary Bird Perkins Cancer Center Baton Rouge, LA Associate Professor Department of Physics and Astronomy
More informationMedical Imaging BMEN Spring 2016
Name Medical Imaging BMEN 420-501 Spring 2016 Homework #4 and Nuclear Medicine Notes All questions are from the introductory Powerpoint (based on Chapter 7) and text Medical Imaging Signals and Systems,
More informationCLINICAL ASPECTS OF COMPACT GANTRY DESIGNS
CLINICAL ASPECTS OF COMPACT GANTRY DESIGNS J. Heese, J. Wulff, A. Winnebeck, A. Huggins, M. Schillo VARIAN PARTICLE THERAPY JUERGEN HEESE New gantry developments Viewpoint from user and vendor perspective
More informationSimulation of Diffuse Optical Tomography using COMSOL Multiphysics
Simulation of Diffuse Optical Tomography using COMSOL Multiphysics SAM Kirmani *1 L Velmanickam 1 D Nawarathna 1 SS Sherif 2 and IT Lima Jr 1 1 Department of Electrical and Computer Engineering North Dakota
More informationVoxels and Medical Applications. FLUKA Beginners course
Voxels and Medical Applications FLUKA Beginners course The FLUKA voxel geometry It is possible to describe a geometry in terms of voxels, i.e., tiny parallelepipeds (all of equal size) forming a 3-dimensional
More informationIntegrated proton-photon treatment planning
Pinnacle 3 Proton Planning Integrated proton-photon treatment planning Philips Pinnacle 3 Proton Planning specifications Pinnacle 3 Proton Planning is designed to simplify treatment planning for proton
More informationBME I5000: Biomedical Imaging
1 Lucas Parra, CCNY BME I5000: Biomedical Imaging Lecture 4 Computed Tomography Lucas C. Parra, parra@ccny.cuny.edu some slides inspired by lecture notes of Andreas H. Hilscher at Columbia University.
More informationAn Intuitive Explanation of Fourier Theory
An Intuitive Explanation of Fourier Theory Steven Lehar slehar@cns.bu.edu Fourier theory is pretty complicated mathematically. But there are some beautifully simple holistic concepts behind Fourier theory
More informationADVANCING CANCER TREATMENT
The RayPlan treatment planning system makes proven, innovative RayStation technology accessible to clinics that need a cost-effective and streamlined solution. Fast, efficient and straightforward to use,
More informationIndex. aliasing artifacts and noise in CT images, 200 measurement of projection data, nondiffracting
Index Algebraic equations solution by Kaczmarz method, 278 Algebraic reconstruction techniques, 283-84 sequential, 289, 293 simultaneous, 285-92 Algebraic techniques reconstruction algorithms, 275-96 Algorithms
More information