1 GeoPT - OshBO, Alkaline Granite Veranstalter: International Association of Geoanalysts and Geostandards Newsletter - GeoPT Ringversuchsmaterial: OshBO, Alkaline Granite RV geschlossen: 0 Literatur: Proficiency Testing Report GeoPT (Laborcode CRB = O0) Hauptelemente [MA%] CRB RV srv Z-Score Na₂O,, 0,0 --- MgO 0, Al₂O₃,,0 --- SiO₂,0, 0, --- P₂O 0, K₂O,, 0,0 --- CaO 0, 0, 0, TiO₂ 0, Fe₂O₃ tot. 0, 0, 0, MnO 0, 0, 0, L.O.I.,0 0, Spurenelemente [µg/g] CRB RV srv Z-Score Ba 0, --- Cr,, --- Cu, 0, --- F Sr --- Legende CRB: Ergebnisse CRB RV: Ergebnisse Ringversuch -- s-rv: Standardabweichung Ringversuch Z-Score: Differenz des Messwertes vom Mittelwert des Ringversuchs -- * Wert nicht zertifiziert

2 GEOPT - AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES - REPORT ON ROUND / January 0 (OShBO - alkaline granite) Philip J. Potts *, Michael Thompson, Simon R.N. Chenery, Peter C. Webb and B. Batjargal Department of Earth Sciences, The Open University, Walton Hall, Milton Keynes, MK AA, UK. Department of Chemistry, Birkbeck College, Gordon House, London, WCH 0PP, UK. British Geological Survey, Keyworth, Nottingham, NG GG, UK. Central Geological, Trade Union Street, Ulaanbaatar-, Mongolia. *Corresponding author: p.j.potts@open.ac.uk Keywords: Proficiency testing, quality assurance, GeoPT, GeoPT round, OShBO, alkaline granite Abstract Results are presented for GeoPT, round fourteen of the GeoPT international proficiency testing programme for analytical geochemistry laboratories. The sample distributed for this round was OShBO, an alkaline granite sample collected and prepared as a candidate reference material by Central Geological Laboratories, Mongolia. In this report, contributed data are listed, together with an assessment of assigned values, z-scores and charts showing both the distribution of contributed results and the overall performance of participating laboratories. tabulated by the organisers and z-scores calculated by comparing each analysed result submitted with the value assigned to be the best estimate of the true composition. These assigned values were estimated by robust statistical analysis of all the contributed data. By examining the magnitude of the z-score, participating laboratories can decide whether the quality of their data is satisfactory in relation to both their chosen fitness-for-purpose criteria and results submitted by all the other laboratories contributing to the round, and choose to take corrective action if this appears justified. Introduction This fourteenth round of the international proficiency testing programme, GeoPT, was conducted in a similar manner to earlier rounds. The programme is designed to be part of the routine quality assurance scheme of analytical geochemistry laboratories. The trial involves distributing a sample of established homogeneity to participating laboratories, which are required to analyse the sample using a wellcharacterised technique or techniques operated under routine analytical conditions. Results are then Full details of the programme have been included in reports of previous rounds, the current publication status of which is listed in Appendix. More specifically, the procedures followed in this round comply with the protocol published for conducting the GeoPT series of proficiency tests (see In this report, therefore, only the features of the present round are included and readers interested in further details are invited to review the GeoPT protocol and previously published reports. GeoPT Report January 0

3 Steering Committee for Round : M. Thompson (Chair), P.J. Potts (Secretary), S.R.N. Chenery, P.C. Webb and B. Batjargal. Sample: The alkaline granite sample (OShBO) used in GeoPT was collected and prepared as a candidate reference material by the Central Geological, Ulaanbaatar, Mongolia. The sample was tested for homogeneity by selecting at random ten packets of the sample prepared for distribution. Duplicate test portions from each packet were analysed by WD-XRF at the OU. For the elements for which values could be assigned, homogeneity was considered to be satisfactory for use in the GeoPT round. An analysis of the results with additional comments is listed in Appendix. Timetable for GeoPT: Distribution of sample: September 0. Deadline for submission of analytical results: th November 0. Distribution of draft report: January 0 Submission of results Results submitted by the seventy-eight laboratories that participated in this round are listed in Table. All these data were used for the assessment of assigned values. Assigned values Following procedures described in earlier rounds, a robust statistical procedure was used to derive assigned value concentrations [Xa], these being judged to be the best estimates of the true composition of this sample. Data in Table lists assigned values for majors and trace elements. Values were assigned on the basis that: (i) sufficient laboratories had contributed data for an element, (ii) the statistical assessment gave confidence that the results showed a central portion approximating to a normal distribution. Part of this assessment involved examining a bar chart for each element to judge the distribution of results. Bar charts for elements shown in Figure were judged to have satisfactory distributions, namely: SiO, Al O, Fe O T, MnO, CaO, Na O, K O, LOI*, Ba*, Be*, Bi*, Ce, Cr, Cs, Cu*, Dy, Er, Eu*, Ga, Gd, Hf, Ho, La, Lu, Nb, Nd, Ni*, Pb, Pr, Rb, Sb, Sc, Sm, Sn*, Sr, Ta*, Tb, Th, Tl*, Tm, U, W*, Y*, Yb, Zn and Zr. The elements marked with a * are judged to have provisional assigned values, principally because data distributions plotted in Figure possess some degree of asymmetry. Charts in Figure show distribution data for elements that were not judged to be sufficiently satisfactory in the statistical analysis to assign values. In the present round, values could not be assigned to the following elements, despite the availability of sufficient analytical results: TiO, FeO, MgO, P O, H O +, CO *, As*, Cd*, Co*, F*, Ge*, Li*, Mo* and V*. The elements marked with a * are presented in Figure with guidance values. There is some degree of consensus in results reported for these elements to provide some guidance to contributing laboratories. However, these data must be interpreted with caution. For other elements that are not included in either of these two lists, insufficient data was reported to allow any assessment to be made. The most common reasons for elements failing the assessment of assigned values were as follows: (i) Insufficient number of contributed results. (ii) Results showing a strong positive skew in the frequency distribution diagram, sometimes with an indication of multi-modality. (iii) A robust mean clearly different from the mode, which makes the determination of a consensus impracticable. GeoPT Report January 0

4 (iv) A very wide distribution of results as judged by the robust standard deviation value so that no matter where the consensus was placed, most of the participants would receive an unsatisfactory classification if z-scores were calculated. Z-score analysis As in previous rounds, laboratories were invited to choose one of two performance standards against which their analytical results would be judged: Data quality for laboratories working to a 'pure geochemistry' standard of performance, where analytical results are designed for geochemical research and where care is taken to provide data of high precision and accuracy, sometimes at the expense of a reduced sample throughput rate. Data quality for laboratories working to an 'applied geochemistry' standard of performance, where, although precision and accuracy are still important, the main objective is to provide results on large numbers of samples collected as part of geochemical mapping projects or geochemical exploration programmes. The target standard deviation (Ha) for each element assessed was calculated from a modified form of the Horwitz function as follows: Ha = k.xa 0. Where Xa is the concentration of the element expressed as a fraction, and the factor k = 0.0 for pure geochemistry labs and k = 0.0 for applied geochemistry labs. Z-scores were calculated for each elemental result submitted by each laboratory from: z = [X - Xa] / Ha where: X is the contributed result, Xa is the assigned value and Ha is the target standard deviation. Z-score results are listed in Table and participating laboratories are invited to assess their performance using the following criterion: Z-score results in the range -<z< are considered to be 'satisfactory' (in the sense that no action is called for by the participant). If the z-score for any element falls outside this range, contributing laboratories are advised to examine their procedures to ensure that determinations are not subject to unsuspected analytical bias. Overall performance A summary of the overall performance of individual laboratories in this round is plotted in Figure as a multiple z-score chart. In this chart, the z-score performance for each element is distinguished by symbols that make it simple to identify whether the results were satisfactory or gave z-scores that exceeded the action limits. This chart is designed to help individual laboratories to judge their overall performance in this proficiency testing round. Participation in future rounds The benefit from proficiency testing arises from regular participation and laboratories are invited to contribute to the GeoPT round, the sample for which will be distributed during March 0. Acknowledgments The authors thank Jann Matela and Liz Lomas (OU) for valued assistance with the production of this report. The GeoPT programme is organised on behalf of the International Association of Geoanalysts. GeoPT Report January 0

5 Appendix Publication status of proficiency testing reports GeoPT Thompson M., Potts P.J., Kane J.S. and Webb P.C. () GeoPT. International proficiency test for analytical geochemistry laboratories - Report on round. Geostandards Newsletter: The Journal of Geostandards and Geoanalysis,, -. GeoPT Thompson M., Potts P.J., Kane J.S., Webb P.C. and Watson, J.S. () GeoPT. International proficiency test for analytical geochemistry laboratories - Report on round. Geostandards Newsletter: The Journal of Geostandards and Geoanalysis, -. GeoPT Thompson M., Potts P.J., Kane J.S. and Chappell B.W. (a) GeoPT. International proficiency test for analytical geochemistry laboratories - Report on round. Geostandards Newsletter: The Journal of Geostandards and Geoanalysis,, -. GeoPT Thompson M., Potts P.J., Kane J.S., Webb P.C. and Watson J.S. (b) GeoPT. International proficiency test for analytical geochemistry laboratories - Report on round. Published in the electronic version of Geostandards Newsletter: The Journal of Geostandards and Geoanalysis (Summer 00). GeoPT Thompson M., Potts P.J., Kane J.S., and Wilson S. (c) GeoPT. International proficiency test for analytical geochemistry laboratories - Report on round. Published in the electronic version of Geostandards Newsletter: The Journal of Geostandards and Geoanalysis (Summer 00). GeoPT Potts P.J., Thompson M., Kane J.S., Webb P.C. and Carignan J. (00) GEOPT - an international proficiency test for analytical geochemistry laboratories - report on round (OU-: Nanhoron microgranite) and A (CAL-S: CRPG limestone). International Association of Geoanalysts: Unpublished report. GeoPT Potts P.J., Thompson M., Kane J.S., Webb, P.C. and Watson J.S. (00) GEOPT - an international proficiency test for analytical geochemistry laboratories - report on round / February 0 (OU- Penmaenmawr microdiorite). International Association of Geoanalysts: Unpublished report. GeoPT Potts P.J., Thompson M., Webb, P.C. and Watson J.S. (0) GEOPT - an international proficiency test for analytical geochemistry laboratories - report on round / July 0 (OU- Penrhyn slate). International Association of Geoanalysts: Unpublished report. GeoPT Potts P.J., Thompson M., Webb, P.C., Watson J.S. and Wang Yimin (0) GEOPT - an international proficiency test for analytical geochemistry laboratories - report on round / December 0 (CH- Marine sediment). International Association of Geoanalysts: Unpublished report. GeoPT Potts P.J., Thompson M., S.R. Chenery, Webb, P.C. and Watson J.S. (0) GEOPT - an international proficiency test for analytical geochemistry laboratories - report on round / July 0 (OU- Leaton dolerite). International Association of Geoanalysts: Unpublished report. GeoPT Potts P.J., Thompson M., S.R. Chenery, Webb, P.C. and B. Batjargal (0) GEOPT - an international proficiency test for analytical geochemistry laboratories - report on round / January 0 (GAS Serpentinite). International Association of Geoanalysts: Unpublished report. GeoPT Potts P.J., Thompson M., S.R. Chenery, Webb, P.C. and H.U. Kaspar (0) GEOPT - an international proficiency test for analytical geochemistry laboratories - report on round / July 0 (Köln Loess). International Association of Geoanalysts: Unpublished report. GeoPT Potts P.J., Thompson M., Kane J.S., and Petrov L.L. (00) GEOPT - an international proficiency test for analytical geochemistry laboratories - report on round (GBPG- Garnet-biotite plagiogneiss). International Association of Geoanalysts: Unpublished report. GeoPT Report January 0

6 Table : GeoPT Results submitted (Nov 0) by laboratories to the GeoPT round for OShBO (alkaline granite). Round identifier O O O O O O O O O O O O O O O Sample OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO Technique codes X ISE,X ISE,X IR,X M M X X X I I A,M I AA,T,M, M X Test portion (g) Data quality SiO % m/m TiO % m/m AlO % m/m FeO % m/m Fe(II)O % m/m 0. MnO % m/m MgO % m/m CaO % m/m NaO % m/m KO % m/m PO % m/m HO+ % m/m CO % m/m LOI % m/m Ag As... Au 0.00 B Ba..... Be. Bi Br Cd 0. Ce.0... Cl Co Cr. Cs... Cu.. Dy.... Er.... Eu F 00 Ga... Gd.... Ge. Hf Hg Ho I In Ir La Li Lu Mo 0. N Nb.... Nd..... Ni... Os Pb... Pd Pr.... Pt Rb 00 Re Rh Ru S. Sb Sc Se Sm Sn Sr..... Ta... Tb Te Th Tl. Tm U V.... W.. Y Yb Zn 0.. Zr.0.. Technique codes: A=ICP-AES; AA=AAS; C=colorimetry; E=(atomic) emission spectrometry; G=gravimetric; I=INAA; IR= infra red detection; ISE=ion selective electrodes; M=ICP-MS; O=other; S=spectrophotometry, T=titrimetry; W=wet chemistry; X=X-ray fluorescence. Results L0 to L were submitted too late to contribute to the assessment of assigned values.

7 Round identifier Sample Technique codes Test portion (g) Data quality SiO % m/m TiO % m/m AlO % m/m FeO % m/m Fe(II)O % m/m MnO % m/m MgO % m/m CaO % m/m NaO % m/m KO % m/m PO % m/m HO+ % m/m CO % m/m LOI % m/m Ag As Au B Ba Be Bi Br Cd Ce Cl Co Cr Cs Cu Dy Er Eu F Ga Gd Ge Hf Hg Ho I In Ir La Li Lu Mo N Nb Nd Ni Os Pb Pd Pr Pt Rb Re Rh Ru S Sb Sc Se Sm Sn Sr Ta Tb Te Th Tl Tm U V W Y Yb Zn Zr Table : GeoPT Results submitted (Nov 0) by laboratories to the GeoPT round for OShBO (alkaline granite). O O O O O O O O O O O O O O O OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO X X IR,T,X A,AA,M, A,AA,M, AA,C X X I V,X X X AA,A,IS X M,X X X E,X Technique codes: A=ICP-AES; AA=AAS; C=colorimetry; E=(atomic) emission spectrometry; G=gravimetric; I=INAA; IR= infra red detection; ISE=ion selective electrodes; M=ICP-MS; O=other; S=spectrophotometry, T=titrimetry; W=wet chemistry; X=X-ray fluorescence. Results L0 to L were submitted too late to contribute to the assessment of assigned values.

8 Round identifier Sample Technique codes Test portion (g) Data quality SiO % m/m TiO % m/m AlO % m/m FeO % m/m Fe(II)O % m/m MnO % m/m MgO % m/m CaO % m/m NaO % m/m KO % m/m PO % m/m HO+ % m/m CO % m/m LOI % m/m Ag As Au B Ba Be Bi Br Cd Ce Cl Co Cr Cs Cu Dy Er Eu F Ga Gd Ge Hf Hg Ho I In Ir La Li Lu Mo N Nb Nd Ni Os Pb Pd Pr Pt Rb Re Rh Ru S Sb Sc Se Sm Sn Sr Ta Tb Te Th Tl Tm U V W Y Yb Zn Zr Table : GeoPT Results submitted (Nov 0) by laboratories to the GeoPT round for OShBO (alkaline granite). O O O O O O O O O O O O O O O OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO X X A,IR,M,X X T,X X X X X X X M M,X A,ir,ISE, X M,V Technique codes: A=ICP-AES; AA=AAS; C=colorimetry; E=(atomic) emission spectrometry; G=gravimetric; I=INAA; IR= infra red detection; ISE=ion selective electrodes; M=ICP-MS; O=other; S=spectrophotometry, T=titrimetry; W=wet chemistry; X=X-ray fluorescence. Results L0 to L were submitted too late to contribute to the assessment of assigned values.

9 Round identifier Sample Technique codes Test portion (g) Data quality SiO % m/m TiO % m/m AlO % m/m FeO % m/m Fe(II)O % m/m MnO % m/m MgO % m/m CaO % m/m NaO % m/m KO % m/m PO % m/m HO+ % m/m CO % m/m LOI % m/m Ag As Au B Ba Be Bi Br Cd Ce Cl Co Cr Cs Cu Dy Er Eu F Ga Gd Ge Hf Hg Ho I In Ir La Li Lu Mo N Nb Nd Ni Os Pb Pd Pr Pt Rb Re Rh Ru S Sb Sc Se Sm Sn Sr Ta Tb Te Th Tl Tm U V W Y Yb Zn Zr Table : GeoPT Results submitted (Nov 0) by laboratories to the GeoPT round for OShBO (alkaline granite). O O O O0 O O O O O O O O O O O OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO A A,ir,M,X X X A AA,ISE, W,X I I X A,M X M,X I X X <0, < < 0, < < Technique codes: A=ICP-AES; AA=AAS; C=colorimetry; E=(atomic) emission spectrometry; G=gravimetric; I=INAA; IR= infra red detection; ISE=ion selective electrodes; M=ICP-MS; O=other; S=spectrophotometry, T=titrimetry; W=wet chemistry; X=X-ray fluorescence. Results L0 to L were submitted too late to contribute to the assessment of assigned values.

10 Round identifier Sample Technique codes Test portion (g) Data quality SiO % m/m TiO % m/m AlO % m/m FeO % m/m Fe(II)O % m/m MnO % m/m MgO % m/m CaO % m/m NaO % m/m KO % m/m PO % m/m HO+ % m/m CO % m/m LOI % m/m Ag As Au B Ba Be Bi Br Cd Ce Cl Co Cr Cs Cu Dy Er Eu F Ga Gd Ge Hf Hg Ho I In Ir La Li Lu Mo N Nb Nd Ni Os Pb Pd Pr Pt Rb Re Rh Ru S Sb Sc Se Sm Sn Sr Ta Tb Te Th Tl Tm U V W Y Yb Zn Zr Table : GeoPT Results submitted (Nov 0) by laboratories to the GeoPT round for OShBO (alkaline granite). O O O O O O O O O O O O O0 O O OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO X A,M AA,A,E,I AA,A,E,I X A,M,O,X M,X AA,E,O, AA,O,T, X X A,M,X X M M SE, SE, S,X X Technique codes: A=ICP-AES; AA=AAS; C=colorimetry; E=(atomic) emission spectrometry; G=gravimetric; I=INAA; IR= infra red detection; ISE=ion selective electrodes; M=ICP-MS; O=other; S=spectrophotometry, T=titrimetry; W=wet chemistry; X=X-ray fluorescence. Results L0 to L were submitted too late to contribute to the assessment of assigned values.

11 Round identifier Sample Technique codes Test portion (g) Data quality SiO % m/m TiO % m/m AlO % m/m FeO % m/m Fe(II)O % m/m MnO % m/m MgO % m/m CaO % m/m NaO % m/m KO % m/m PO % m/m HO+ % m/m CO % m/m LOI % m/m Ag As Au B Ba Be Bi Br Cd Ce Cl Co Cr Cs Cu Dy Er Eu F Ga Gd Ge Hf Hg Ho I In Ir La Li Lu Mo N Nb Nd Ni Os Pb Pd Pr Pt Rb Re Rh Ru S Sb Sc Se Sm Sn Sr Ta Tb Te Th Tl Tm U V W Y Yb Zn Zr Table : GeoPT Results submitted (Nov 0) by laboratories to the GeoPT round for OShBO (alkaline granite). O O O O O O O O O O O O O O O OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO A,M,X A,M,T,X M,X A,I,M,X X AA,A,M, X A,M,X X AA,S,T, X M,X AA,G,S X A,M,X - A,AA,ir, T,X Technique codes: A=ICP-AES; AA=AAS; C=colorimetry; E=(atomic) emission spectrometry; G=gravimetric; I=INAA; IR= infra red detection; ISE=ion selective electrodes; M=ICP-MS; O=other; S=spectrophotometry, T=titrimetry; W=wet chemistry; X=X-ray fluorescence. Results L0 to L were submitted too late to contribute to the assessment of assigned values.

12 Round identifier Sample Technique codes Test portion (g) Data quality SiO % m/m TiO % m/m AlO % m/m FeO % m/m Fe(II)O % m/m MnO % m/m MgO % m/m CaO % m/m NaO % m/m KO % m/m PO % m/m HO+ % m/m CO % m/m LOI % m/m Ag As Au B Ba Be Bi Br Cd Ce Cl Co Cr Cs Cu Dy Er Eu F Ga Gd Ge Hf Hg Ho I In Ir La Li Lu Mo N Nb Nd Ni Os Pb Pd Pr Pt Rb Re Rh Ru S Sb Sc Se Sm Sn Sr Ta Tb Te Th Tl Tm U V W Y Yb Zn Zr Table : GeoPT Results submitted (Nov 0) by laboratories to the GeoPT round for OShBO (alkaline O O O OShBO OShBO OShBO A,X A,M,X A,ir,M,T, X Technique codes: A=ICP-AES; AA=AAS; C=colorimetry; E=(atomic) emission spectrometry; G=gravimetric; I=INAA; IR= infra red detection; ISE=ion selective electrodes; M=ICP-MS; O=other; S=spectrophotometry, T=titrimetry; W=wet chemistry; X=X-ray fluorescence. Results L0 to L were submitted too late to contribute to the assessment of assigned values.

13 Table GeoPT (OShBO-alkaline granite) Assigned values and robust statistical analysis of contributed data X a H a sdm sdm/h a status X a H a sdm sdm/h a status % m/m % m/m % m/m mg/kg mg/kg mg/kg SiO assigned Lu assigned AlO assigned Nb assigned FeO assigned Nd assigned MnO assigned Ni provisional CaO assigned Pb assigned NaO assigned Pr assigned KO assigned Rb 0. assigned LOI provisional Sb assigned mg/kg mg/kg mg/kg Sc assigned Ba provisional Sm assigned Be provisional Sn provisional Bi provisional Sr assigned Ce assigned Ta provisional Cr assigned Tb assigned Cs assigned Th assigned Cu provisional Tl provisional Dy assigned Tm assigned Er assigned U assigned Eu provisional W provisional Ga assigned Y provisional Gd assigned Yb assigned Hf assigned Zn assigned Ho assigned Zr assigned La assigned X a=assigned value calculated as the robust mean of submitted data. H a=target precision calculated using a modified version of the Horwitz equation for Data quality (Ha=0.0Xa 0. ). sdm=standard deviation of the mean calculated from submitted data using robust statistics.

14 Table : GeoPT Z-scores for laboratories participating in the GeoPT round for OShBO (alkaline granite). Round identifier O O O O O O O O O O O O O O O O O O O O O O O O Sample OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO Technique codes X ISE,X ISE,X IR,X M M X X X I I A,M I AA,T, M X X IR,T,X A,AA, A,AA, AA,C X X I M,X M,X M,X Test portion (g) Data quality SiO * -0. * * * * * 0.0 * 0.0 * * * AlO. -0. * -0. * * * * * * * * FeO. -0. * -. * * 0.. * * * * MnO. 0. * -0. * * * * * * * * CaO. -. * -. * * -0.. * * *.0 * -0. * * * NaO.. * 0.0 * * * * * * KO. -0. * 0. * * * * * * * LOI * 0. * -. * * * * *. * -. * * * Ba * * * * -.0 * * *.0 * * 0. * * * * 0.0 * * * * Be * * * * * * * * * * * * * * 0. * * * * -. * * * * Bi * * * * * * * * * * * * * * * * * * * * *. * * Ce * * * *. * * * * -0. * * * * -. * * *. Cr * * * -0. * * * * -. * *. * -0. * Cs * * * * 0. * * * * * * * * * * * * -. Cu * * * * * * *. * * *. * -0. * * * * * * * * Dy * * * * 0. * * * * * * * * *. * * * * * Er * * * * 0. * * * * * * -.0 * * * *. * * * * * Eu * * * * -0. * * * *.0 * -. * * * *. * * * *. Ga * * * * * * * * -0. * * * * * -0. * * * * * * Gd * * * * 0. * * * * * * -. * * * *. * * * * * Hf * * * * * 0.0 * * * * * * * * * * * * 0. Ho * * * * 0.0 * * * *. * -0. * * * *. * * * * * La * * * * 0. * * * * 0. * * *. * -0. * * * -0. Lu * * * * 0. * * * * -0. * * * *.0 * * * * * Nb * * * * * * * -. * * * -0. * * -0. * -0. * * 0. * Nd * * * * 0. * * * *.0 * * * -.. * * * *. Ni * * * * * * * -. * * * 0. * * -0. * * -. Pb * * * * -0. * *. * * * * * * -0. * * Pr * * * *. * * * * * * 0. * * * *. * * * * * Rb. * * *.0 * * -0. * * * 0. *. *.0 * -. Sb * * * * * * * * * *..0. * -0. * * * * * * * * 0. Sc * * * * * * * * -. * * * * * -. * * * -. Sm * * * * 0. * * * * 0. * * * *.0 * * * * 0. Sn * * * * * * * * * * * -0. * * * -0. * * * * * * * * Sr * * * * -0. * *. * * * 0. * * 0. *. * * -. * Ta * * * * * * * * * * * * * * * * * * * 0. Tb * * * * 0. * * * *. * * * *. * * * * -. Th * * * * -0. * * *. * * -0. * * * -0. * 0. Tl * * * * * * * * * * * * * *.0 * * * * * * * * * Tm * * * * * * * * * * * 0.0 * * * *. * * * * * U * * * * -0. * * * 0. * * * * * * *. * 0. W * * * * * * * * * * * * * * * * *. * * * -. Y * * * * -0. * * -. * * * -0. *. -0. * *. * -. * 0. * * Yb * * * * 0. * * * * -0. * * * *. * * * *. Zn * * * * * * * 0.0 * * * -. * -.0 * -0. * 0.0 * Zr * * * * * 0. *. * * * -0. * 0.0 *. * -. *. * * 0. * Technique codes: A=ICP-AES; AA=AAS; C=colorimetry; E=(atomic) emission spectrometry; G=gravimetric; I=INAA; IR= infra red detection; ISE=ion selective electrodes; M=ICP-MS; O=other; S=spectrophotometry, T=titrimetry; W=wet chemistry; X=X-ray fluorescence.

15 Round identifier Sample Technique codes Test portion (g) Data quality SiO AlO FeO MnO CaO NaO KO LOI Ba Be Bi Ce Cr Cs Cu Dy Er Eu Ga Gd Hf Ho La Lu Nb Nd Ni Pb Pr Rb Sb Sc Sm Sn Sr Ta Tb Th Tl Tm U W Y Yb Zn Zr Table : GeoPT Z-scores for laboratories participating in the GeoPT round for OShBO (alkaline granite). O O O O O O O O O O O O O O O O O O O O O O O O OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO V,X X X AA,A,I SE,X X M,X X X A,IR,M,X X T,X X X X X X X M M,X A,ir,IS E,M,V X A A,ir,M, X X * * -. * * * * 0.. * * -0. * * * *. 0. * * -. * * * * -.. * * 0. * * * * * *. * * * * *...0 * * -0. * * * * * * -. * * * *... * *. * * * *.. * * * 0. * -. *. * -. * * -. * * * *. *. * * 0. * * * * * -. * * * * 0. * * * * -. * * 0. * -. * * * * * -. * *. 0.. * *. * * * *. * * -0. * *.0 * * * -. *.. * * -. *. *. * * * -0. * * * * * * * -.0 * * * * -. * * * * -0. * * * -. * -. * *. *. * *. * * * *. * 0. * * -0. * * * * * * * * -... * * -. * * * * 0. * 0. * * -. * * * * * * * * * * -. * * * *. * -. * * * * * * * * * * * * * * * *. * * * -.. * -. * * * * * *. * * -0. * * * *. * -0. * * -0. * * * * * * * * * * -. * * * * * * -0. * * -. * * * * -. * * * * * -0. * * * * * * 0. * * -. * * * * * * * * * * -. * * * * -0. * * -.0 * *. * * * * * -. * * * * -0. * 0. * * -0. * * * * * * * * * * -.0 * * * 0. * -0. * -. * * -0. * *. * * * * 0. * * -0. * * * * * * * -. *.. * * * -. *. * *... * *. *. -0. * -0. * * -.0 * -. *. * * * -0. * * * *. * * -. * * * * * * * * * * -. * * * -0. *. * -. * * 0. * * * * *. * * * * -0. * * * * * * * * * * * * * 0. * * *. * * 0. * * * * * * * * * -. * * * * -0. * 0. * * -. * * * * * * * * * * -. * * * * 0. * * * * -. * * * * * * * -..0 * * -. *. 0. * * -. *. * * * *. * * * * * * -0. * * -0. * * * * * * * * * * -. * * * * * * 0. * * -0. * * * * * * * * * * -.0 *. * * -0. * -. * * -. * * * *. * 0. * * -. * * * * * * -. * * -. * * * * * * * * * * * * * * * * * 0. * * -0. * * * * * * * * * * -.0 * * *.0. * -. * * -0. * * * * * * -. * * -0. * * * * * * * * * * * * * * * * * * * * * * *. * -0. *. 0. * -0. * -. * * -0. *. * * -. * * * * * * -.0 * * * * *.0 * * * * -. *. * *. -. * -0. * * -. * -.. * *. *.. * * -.0 *. * * * * -0. * Technique codes: A=ICP-AES; AA=AAS; C=colorimetry; E=(atomic) emission spectrometry; G=gravimetric; I=INAA; IR= infra red detection; ISE=ion selective electrodes; M=ICP-MS; O=other; S=spectrophotometry, T=titrimetry; W=wet chemistry; X=X-ray fluorescence.

16 Round identifier Sample Technique codes Test portion (g) Data quality SiO AlO FeO MnO CaO NaO KO LOI Ba Be Bi Ce Cr Cs Cu Dy Er Eu Ga Gd Hf Ho La Lu Nb Nd Ni Pb Pr Rb Sb Sc Sm Sn Sr Ta Tb Th Tl Tm U W Y Yb Zn Zr Table : GeoPT Z-scores for laboratories participating in the GeoPT round for OShBO (alkaline granite). O0 O O O O O O O O O O O O O O O O O O O O O O O OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO X A AA,IS E,W,X I I X A,M X M,X I X X X A,M AA,A, E,ISE, AA,A, E,ISE, X A,M,O,X M,X AA,E, O,S,X AA,O, T,X X X A,M,X * * * * * * * * * * * -.0 * * * * * * -. * * * * * * -0. * * * * * * * -. * * * * * * * * * * * * *. * * * * *. 0. * * * * * * * * * * *...0 *. *. -0. * * * -.. *. * * * * -.0 * * * * -0. * * * * * * -.0 *. * 0. * -. * * * * * * * * * * * * * * * * * * * *. * * * * -. *. * * -0. * *. * * * * * -. * * * * *. * * -.. * * 0. * * * -0. * *. * * * * * * 0. * *.0 * * * * * * * *.0. * * 0. *.. 0. * -.0. * * * * * *. * * 0.0 *. * * * * * * * * * -. * * -0. * * * * * * 0. *.0 * * * * * * * * *. * * -0. * * * * * * -. *.. * * * * * * * 0. * * 0. * * -. * * -0. * 0. * * * * * *. -0. * * 0. * * * * * * * * * -0. *. * * * * * * * * *. * * 0. * * * 0.0 * * 0. * * * * * *. *. * * -. * * * * * * * * * 0. *. * * * * * * * * *. * * -0. * -. * 0. * * -0. * 0... *. -. * * * *. * * -. * * * -0. * * -0. * * * * 0. * * * * * * * 0.0 * * * * * * * *. * * *. * -.0 * *. * -0. * * * * * * * * * 0. * * *. * * * * -.. * 0. * * * * * * * * * * * * 0. * *.. * * 0. * * * * * * 0. * -0. * * * * * * * * * -0. * * * * * * * -. * * * 0. *. * * * * * * * * * * * -0. * * * -. * * -.0 * * * * -. * 0. * * -0. * * -. *. * -. * * * * * * *. * * -0. *. 0. * * * * * * * * 0. * * -.0 * -..0 * * * -0. * * * * * * -. *. * * * * * * * * * -.. * * 0. * * * * -. * * 0. * * * -. * * 0. * * * * * *. * -.. *. * * * * * * -0. * * 0.0 *. 0. * * * * * * * *. * * 0.0 * * * -0. * * * -0. * * * *.0 * *. * * -0. * * * -. * * * * * * -0. * 0. * 0. * * * * * * * * * * * * -0. * 0. * * * * * * * * * * * * -0. * * * * -. * * -. * * * -0. * * -. * *. * * * * 0. * * * * * * * *. * * * -. * * -. * * * * -. * * * *.0 *. *.. * -. * * * * *. *. * -0. * * -0. * -0.. * * * * * * * *. * * * * *. * * 0.. * * * * * * * *. * 0. * * * 0. Technique codes: A=ICP-AES; AA=AAS; C=colorimetry; E=(atomic) emission spectrometry; G=gravimetric; I=INAA; IR= infra red detection; ISE=ion selective electrodes; M=ICP-MS; O=other; S=spectrophotometry, T=titrimetry; W=wet chemistry; X=X-ray fluorescence.

17 Round identifier Sample Technique codes Test portion (g) Data quality SiO AlO FeO MnO CaO NaO KO LOI Ba Be Bi Ce Cr Cs Cu Dy Er Eu Ga Gd Hf Ho La Lu Nb Nd Ni Pb Pr Rb Sb Sc Sm Sn Sr Ta Tb Th Tl Tm U W Y Yb Zn Zr Table : GeoPT Z-scores for laboratories participating in the GeoPT round for OShBO (alkaline granite). O0 O O O O O O O O O O O O O O O O O O O O OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO OShBO X M M A,M,X A,M,T, X M,X A,I,M, X X AA,A, M,X A,M,X X AA,S,T,X M,X AA,G, S X A,M,X - A,AA,ir,T,X A,X A,M,X A,ir,M, T,X * * * * * * * * * * * * * * * * * -.. * * * * * * * * * * * *. -. * * * 0. * * * * *. 0. * * * -. * * -.0 * 0.0 * -. * * * * * -.0 * -. * * * * * * * * * * * * 0. * * -. *. * * * -0. * * -0. * *. * * *. * -.. * 0. * 0.. * * -. * *. * * *. * * * * * -. * * 0. * -. * * 0. * *. -0. * * -0. * * -.0 * -. * * * * -0.. * -. * * -. *. *. -0. * * *. * 0. * * * -. * * 0. * * * * * *. * 0. * * * -. * * 0. * * * * * * *. * * * * * -. * * -. * * * *. *. * 0.. * * * * * -..0 * * * 0. * *. * 0.0 * * * -. * * 0. * * * * 0. *. * * 0.. * * -. * * 0.0 * -. * * -0. * -0. * -.. *. * 0. * * * -. * * 0. * * * *. * -.. * 0. * 0. * * * -. * * 0. * * * * 0. * -.0. * 0. * 0. * * * -. * * 0. * * * * 0. * -0. * * * * -. * * 0. * * * -0. * 0. * * * -.0 * * 0. * * * * * * * -. * * 0. * 0.0 * * * * * -0.. * * * 0. * * *.0 * -.0. * 0.0 * 0. * * * -0. * * 0. * * * * * 0... * * *. *.0-0. * * * * * 0.0 * * -.0 * -0. * * *. * * -0. * * * * * * * * 0.. * 0. * 0. * * * 0. * *. *. * * * * 0. * -.. *. * -0. * * * -. * *.0 * * * * * * 0. * * * * -. * * -. * *. * * * * * * *. * -. *.. * -. * *. * *. -. * * -. *. * * -0. * 0. * *. * 0. * * * -.0 * * 0. * * * * -0. *.0. * -0. * *.0 -. * * 0. *. * * * * 0.0 * *. *. * * * -0. * * * * * * * -. * -0. * * 0. * * * 0. * * * -. * * 0. * * * * 0. * 0. * -0.. * 0. *. * * * -. * * 0. * * * * -0. *. * * 0. * 0.0 * * *. * * * * * * * * * -0. * 0..0 * * * * * -. * * -0. * * * * 0. * 0. * * * -. * * 0. * * * * *. 0.. * * *. * * -0. * * * *. * * 0. Technique codes: A=ICP-AES; AA=AAS; C=colorimetry; E=(atomic) emission spectrometry; G=gravimetric; I=INAA; IR= infra red detection; ISE=ion selective electrodes; M=ICP-MS; O=other; S=spectrophotometry, T=titrimetry; W=wet chemistry; X=X-ray fluorescence.

18 Concentration SiO / % m/m GeoPT Alkali Granite - Barchart for SiO Concentration AlO / % m/m GeoPT Alkali Granite - Barchart for AlO GeoPT Alkali Granite - Barchart for FeO GeoPT Alkali Granite - Barchart for MnO Concentration FeO / % m/m Concentration MnO / % m/m Concentration CaO / % m/m GeoPT Alkali Granite - Barchart for CaO Concentration NaO / % m/m... GeoPT Alkali Granite - Barchart for NaO 0 0 GeoPT Alkali Granite - Barchart for KO 0 0 GeoPT Alkali Granite - Barchart for LOI Concentration KO / % m/m.0..0 Concentration LOI / % m/m.. 0. Provisional Figure GeoPT OShBO alkaline granite: Data distribution charts for elements for which values were assigned. Horizontal lines show the limits for -<z< for pure geochemistry labs (solid lines) and -<z'< for applied geochemistry labs (pecked lines).

19 GeoPT Alkali granite - Barchart for Ba GeoPT Alkali granite - Barchart for Be Concentration Ba / ppm Provisional Concentration Be / ppm 0 0 Provisional 0 GeoPT Alkali granite - Barchart for Bi GeoPT Alkali granite - Barchart for Ce Concentration Bi / ppm 0 Provisional Concentration Ce / ppm GeoPT Alkali granite - Barchart for Cr GeoPT Alkali granite - Barchart for Cs Concentration Cr / ppm 0 0 Concentration Cs / ppm Concentration Cu / ppm 0 GeoPT Alkali granite - Barchart for Cu Provisional Concentration Dy / ppm... GeoPT Alkali granite - Barchart for Dy 0. Figure GeoPT OShBO alkaline granite: Data distribution charts for elements for which values were assigned. Horizontal lines show the limits for -<z< for pure geochemistry labs (solid lines) and -<z'< for applied geochemistry labs (pecked lines).

20 GeoPT Alkali granite - Barchart for Er GeoPT Alkali granite - Barchart for Eu Concentration Er / ppm.0. Concentration Eu / ppm Provisional GeoPT Alkali granite - Barchart for Ga GeoPT Alkali granite - Barchart for Gd Concentration Ga / ppm 0 0 Concentration Gd / ppm GeoPT Alkali granite - Barchart for Hf GeoPT Alkali granite - Barchart for Ho. Concentration Hf / ppm Concentration Ho / ppm GeoPT Alkali granite - Barchart for La GeoPT Alkali granite - Barchart for Lu 0. Concentration La / ppm Concentration Lu / ppm Figure GeoPT OShBO alkaline granite: Data distribution charts for elements for which values were assigned. Horizontal lines show the limits for -<z< for pure geochemistry labs (solid lines) and -<z'< for applied geochemistry labs (pecked lines).

21 0 GeoPT Alkali granite - Barchart for Nb GeoPT Alkali granite - Barchart for Nd Concentration Nb / ppm Concentration Nd / ppm Concentration Ni / ppm GeoPT Alkali granite - Barchart for Ni Provisional Concentration Pb / ppm GeoPT Alkali granite - Barchart for Pb 0 0 GeoPT Alkali granite - Barchart for Pr 00 GeoPT Alkali granite - Barchart for Rb Concentration Pr / ppm Concentration Rb / ppm GeoPT Alkali granite - Barchart for Sb 0 GeoPT Alkali granite - Barchart for Sc Concentration Sb / ppm Concentration Sc / ppm Figure GeoPT OShBO alkaline granite: Data distribution charts for elements for which values were assigned. Horizontal lines show the limits for -<z< for pure geochemistry labs (solid lines) and -<z'< for applied geochemistry labs (pecked lines).

22 . GeoPT Alkali granite - Barchart for Sm 0 GeoPT Alkali granite - Barchart for Sn Concentration Sm / ppm Concentration Sn / ppm Provisional GeoPT Alkali granite - Barchart for Sr GeoPT Alkali granite - Barchart for Ta Concentration Sr / ppm Concentration Ta / ppm Provisional Concentration Tb / ppm GeoPT Alkali granite - Barchart for Tb Concentration Th / ppm GeoPT Alkali granite - Barchart for Th 0. Concentration Tl / ppm GeoPT Alkali granite - Barchart for Tl Provisional Concentration Tm / ppm GeoPT Alkali granite - Barchart for Tm Figure GeoPT OShBO alkaline granite: Data distribution charts for elements for which values were assigned. Horizontal lines show the limits for -<z< for pure geochemistry labs (solid lines) and -<z'< for applied geochemistry labs (pecked lines).

23 GeoPT Alkali granite - Barchart for U GeoPT Alkali granite - Barchart for W Concentration U / ppm Concentration W / ppm Provisional 0 0 GeoPT Alkali granite - Barchart for Y GeoPT Alkali granite - Barchart for Yb Concentration Y / ppm 0 Provisional Concentration Yb / ppm 0 GeoPT Alkali granite - Barchart for Zn 0 GeoPT Alkali granite - Barchart for Zr Concentration Zn / ppm 0 Concentration Zr / ppm Figure GeoPT OShBO alkaline granite: Data distribution charts for elements for which values were assigned. Horizontal lines show the limits for -<z< for pure geochemistry labs (solid lines) and -<z'< for applied geochemistry labs (pecked lines).

24 Concentration TiO / % m/m GeoPT Alkali granite - Barchart for TiO Concentration Fe(II)O / % m/m GeoPT Alkali granite - Barchart for Fe(II)O Concentration MgO / % m/m GeoPT Alkali granite - Barchart for MgO Concentration PO / % m/m GeoPT Alkali granite - Barchart for PO 0 0 GeoPT Alkali granite - Barchart for HO+ 0 0 GeoPT Alkali granite - Barchart for CO Concentration HO+ / % m/m Concentration CO / % m/m Guidance only Figure GeoPT OShBO alkaline granite: Data distribution charts for elements for which values were not assigned.

25 GeoPT Alkali granite - Barchart for As GeoPT Alkali granite - Barchart for Cd Concentration As / ppm Guidance only Concentration Cd / ppm Guidance only GeoPT Alkali granite - Barchart for Co 000 GeoPT Alkali granite - Barchart for F Concentration Co / ppm Guidance only Concentration F / ppm Guidance only Concentration Ge / ppm 0 GeoPT Alkali granite - Barchart for Ge Guidance only Concentration Li / ppm GeoPT Alkali granite - Barchart for Li Guidance only. GeoPT Alkali granite - Barchart for Mo GeoPT Alkali granite - Barchart for V Concentration Mo / ppm Guidance only Concentration V / ppm Guidance only Figure GeoPT OShBO alkaline granite: Data distribution charts for elements for which values were not assigned.

26 GeoPT Alkali Granite - Multiple z-score Chart Analyte Name SiO AlO FeO MnO CaO NaO KO LOI Ba Be Bi Ce Cr Cs Cu Dy Er Eu Ga Gd Hf Ho La Lu Nb Nd Ni Pb Pr Rb Sb Sc Sm Sn Sr Ta Tb Th Tl Tm UW Y Yb Zn Zr* z<- -<z<- -<z< <z< z> Identity Code Analyte Name SiO AlO FeO MnO CaO NaO KO LOI Ba Be Bi Ce Cr Cs Cu Dy Er Eu Ga Gd Hf Ho La Lu Nb Nd Ni Pb Pr Rb Sb Sc Sm Sn Sr Ta Tb Th Tl Tm UW Y Yb Zn Zr* z<- -<z<- -<z< <z< z> 0 Identity Code Analyte Name SiO AlO FeO MnO CaO NaO KO LOI Ba Be Bi Ce Cr Cs Cu Dy Er Eu Ga Gd Hf Ho La Lu Nb Nd Ni Pb Pr Rb Sb Sc Sm Sn Sr Ta Tb Th Tl Tm UW Y Yb Zn Zr* z<- -<z<- -<z< <z< z> 0 Identity Code Figure GeoPT OShBO alkaline granite: Multiple z-score charts for laboratories participating in the GeoPT round. Symbols indicate whether or not an elemental result complies with the -<z<+ criteria Satisfactory data are plotted as ' '. Data for other categories are plotted as follows: z<- ( ), -<z<- ( ), +<z<+ ( ), Z>+ ( ).

GEOPT19 - AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES REPORT ON ROUND 19 / July 2006 (Gabbro, MGR-N)

GEOPT19 - AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES REPORT ON ROUND 19 / July 2006 (Gabbro, MGR-N) GEOPT19 - AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES REPORT ON ROUND 19 / July 2006 (Gabbro, MGR-N) Peter C. Webb 1 *, Michael Thompson 2, Philip J. Potts 1 and B. Batjargal

More information

GeoPT22 - MBL-1, Basalt

GeoPT22 - MBL-1, Basalt GeoPT22 - MBL-1, Basalt Veranstalter: International Association of Geoanalysts and Geostandards Newsletter - GeoPT22 Ringversuchsmaterial: MBL-1, Basalt RV geschlossen: 2008 2 Literatur: Proficiency Testing

More information

GEOPT10 - AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES - REPORT ON ROUND 10 / December 2001 (CH-1 marine sediment).

GEOPT10 - AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES - REPORT ON ROUND 10 / December 2001 (CH-1 marine sediment). GEOPT10 - AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES - REPORT ON ROUND 10 / December 2001 (CH-1 marine sediment). Philip J. Potts 1 *, Michael Thompson 2, Peter C. Webb

More information

GEOPT13 - AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES - REPORT ON ROUND 13 / July 2003 (Köln Loess)

GEOPT13 - AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES - REPORT ON ROUND 13 / July 2003 (Köln Loess) GEOPT13 - AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES - REPORT ON ROUND 13 / July 2003 (Köln Loess) Philip J. Potts 1 *, Michael Thompson 2, Simon R.N. Chenery 3, Peter C.

More information

AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES REPORT ON ROUND

AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES REPORT ON ROUND GeoPT23 AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES REPORT ON ROUND 23 (Separation Lake pegmatite, OU-9) and 23A (Manganese nodule, FeMn-1) / August 2008 Peter C. Webb 1

More information

ENDF/B-VII.1 versus ENDFB/-VII.0: What s Different?

ENDF/B-VII.1 versus ENDFB/-VII.0: What s Different? LLNL-TR-548633 ENDF/B-VII.1 versus ENDFB/-VII.0: What s Different? by Dermott E. Cullen Lawrence Livermore National Laboratory P.O. Box 808/L-198 Livermore, CA 94550 March 17, 2012 Approved for public

More information

Activity concentration for exempt material (Bq/g)

Activity concentration for exempt material (Bq/g) 173.436 Exempt material activity concentrations and exempt consignment activity limits for radionuclides. The Table of Exempt material activity concentrations and exempt consignment activity limits for

More information

Row 1 This is data This is data

Row 1 This is data This is data mpdf TABLES CSS Styles The CSS properties for tables and cells is increased over that in html2fpdf. It includes recognition of THEAD, TFOOT and TH. See below for other facilities such as autosizing, and

More information

Row 1 This is data This is data. This is data out of p This is bold data p This is bold data out of p This is normal data after br H3 in a table

Row 1 This is data This is data. This is data out of p This is bold data p This is bold data out of p This is normal data after br H3 in a table mpdf TABLES CSS Styles The CSS properties for tables and cells is increased over that in html2fpdf. It includes recognition of THEAD, TFOOT and TH. See below for other facilities such as autosizing, and

More information

ICP-OES. By: Dr. Sarhan A. Salman

ICP-OES. By: Dr. Sarhan A. Salman ICP-OES By: Dr. Sarhan A. Salman AGENDA -- ICP-OES Overview - Module removal Optical components and gas control overview Module replacement --Continue module replacement Manual optical alignment --Precise

More information

LA ICP MS Analysis with

LA ICP MS Analysis with LA ICP MS Analysis with V 1.0.4 04.06.2008 Software written by Murray Allan at Die Eidgenössische Technische Hochschule Zürich, CH and the University of Leeds, UK Additional Software writing: Dimitri Meier

More information

Waleed Pervaiz CSE 352

Waleed Pervaiz CSE 352 Waleed Pervaiz CSE 352 Classification Tool: WEKA Waikato Environment for Knowledge Analysis by The University of Waikato. Available on the internet at: http://www.cs.waikato.ac.nz/~ml/weka/index.html The

More information

So il Geochem ica l Ba seline and Env ironm en ta l Background Va lues of Agr icultura l Reg ion s in Zhejiang Prov ince.

So il Geochem ica l Ba seline and Env ironm en ta l Background Va lues of Agr icultura l Reg ion s in Zhejiang Prov ince. 2007, 23 (2) : 81-88 Journal of Ecology and Rural Environm ent 1, 1, 2, 1 (1., 311203;, 065000) 2. :,, 13,,, 52(), : ; ; ; : P632; X8; P59 : A: 1673-4831 (2007) 02-0081 - 08 So il Geochem ica l Ba seline

More information

LBMA Proficiency Testing

LBMA Proficiency Testing LBMA Proficiency Testing Jonathan J. Jodry Metalor Technologies SA, Switzerland LBMA Assaying and Refining Conference 20-21 March 2017, London Topics What is a Proficiency Testing? Sample composition,

More information

REE-mineralogy of Suhuvaara appinite, Inari, Northern Finland Thair Al-Ani and Olli Sarapää

REE-mineralogy of Suhuvaara appinite, Inari, Northern Finland Thair Al-Ani and Olli Sarapää Northern Finland Unit M42/2010/67 22.2.2011 Rovaniemi REE-mineralogy of Suhuvaara appinite, Inari, Northern Finland Thair Al-Ani and Olli Sarapää GEOLOGICAL SURVEY OF FINLAND DOCUMENTATION PAGE Date /

More information

IPR Äspö Hard Rock Laboratory. International Progress Report. TRUE Block Scale project. Summary of chemical data December 2002

IPR Äspö Hard Rock Laboratory. International Progress Report. TRUE Block Scale project. Summary of chemical data December 2002 International Progress Report IPR-03-25 Äspö Hard Rock Laboratory TRUE Block Scale project Summary of chemical data December 2002 Jeanette Carmström SKB April 2003 Svensk Kärnbränslehantering AB Swedish

More information

New Generation Explorer Handheld XRF. EXPLORER 7000 Mineral Ore Analyzer

New Generation Explorer Handheld XRF. EXPLORER 7000 Mineral Ore Analyzer New Generation Explorer Handheld XRF EXPLORER 7000 Mineral Ore Analyzer EXPLORER 7000 Mineral Ore XRF Based on ten-year research and development experience in Handheld X-Ray Fluorescense, Skyray Instruments

More information

ISO INTERNATIONAL STANDARD. Water quality Digestion for the determination of selected elements in water Part 2: Nitric acid digestion

ISO INTERNATIONAL STANDARD. Water quality Digestion for the determination of selected elements in water Part 2: Nitric acid digestion INTERNATIONAL STANDARD ISO 15587-2 First edition 2002-03-01 Water quality Digestion for the determination of selected elements in water Part 2: Nitric acid digestion Qualité de l'eau Digestion pour la

More information

Supporting Information. Highly Selective and Reversible Chemosensor for Pd 2+ Detected by Fluorescence, Colorimetry and Test Paper.

Supporting Information. Highly Selective and Reversible Chemosensor for Pd 2+ Detected by Fluorescence, Colorimetry and Test Paper. Supporting Information Highly Selective and Reversible Chemosensor for Pd 2+ Detected by Fluorescence, Colorimetry and Test Paper Mian Wang, Xiaomei Liu, Huizhe Lu, Hongmei Wang* and Zhaohai Qin* Department

More information

NOTES on: An NJOY Processing Caution when Doppler Broadening

NOTES on: An NJOY Processing Caution when Doppler Broadening NOTES on: An NJOY Processing Caution when Doppler Broadening 1. Some references about Doppler Broadening CIELO processing Example of files in JEFF-3.2 Example of files in JENDL4.u 2. NJOY versions Official

More information

The Pyramid Table. The Four Matrices; Top Level, Matrix; x = 1. Matrix; x = 2

The Pyramid Table. The Four Matrices; Top Level, Matrix; x = 1. Matrix; x = 2 The Janet Periodic Table (first printed 1928) is also known as the Left Step Table. The Janet table orders the elements according to the filling sequence of the atom. This table may be re-organized as

More information

VI... VIII

VI... VIII - 23 2017 2017 ... VI... VIII... 1 1... 2... 2 1.1... 2 1.1.1... 2 1.1.2... 9 1.1.3... 13 1.1.4... 25 1.1.5... 29 1.1.6... 34 1.1.7... 37 1.1.8... 42 1.2... 47 1.2.1... 47 1.2.2 -... 49 1.2.3... 50 1.2.4

More information

XRF for Regulatory Programs RoHS and Consumer Safety Compliance

XRF for Regulatory Programs RoHS and Consumer Safety Compliance Compact X-ray Fluorescence Xpert XRF for Regulatory Programs RoHS and Consumer Safety Compliance RoHS CPSIA EN71-3 Proposition 65 The Xpert for Regulatory Programs Consumer Safety and RoHS Compliance The

More information

Thermo Scientific Niton XL2 GOLDD Series Environmental Analyzers Elemental Limits of Detection in SiO 2

Thermo Scientific Niton XL2 GOLDD Series Environmental Analyzers Elemental Limits of Detection in SiO 2 Thermo Scientific Niton XL2 GOLDD Series Environmental Analyzers Elemental Limits of Detection in SiO 2 and SRM Matrices Using Soil Analysis In addition to the offices listed below, Thermo Scientific Niton

More information

DATA REPOSITORY. G. Di Vincenzo, A. Grande, F. Rossetti CONTENTS

DATA REPOSITORY. G. Di Vincenzo, A. Grande, F. Rossetti CONTENTS DATA REPOSITORY Paleozoic siliciclastic rocks from northern Victoria Land (Antarctica): provenance, timing of deformation and implications for the Antarctica/Australia connection G. Di Vincenzo, A. Grande,

More information

Quality of Semiconductor Raw Materials: Evolution and Challenges. Yongqiang Lu Kevin McLaughlin

Quality of Semiconductor Raw Materials: Evolution and Challenges. Yongqiang Lu Kevin McLaughlin Quality of Semiconductor Raw Materials: Evolution and Challenges Yongqiang Lu Kevin McLaughlin Outline Advance of Fab technologies and the evolution of raw materials for ever higher quality Challenges:

More information

Version 1.0. General Certificate of Education (A-level) June Mathematics MD01. (Specification 6360) Decision 1. Final.

Version 1.0. General Certificate of Education (A-level) June Mathematics MD01. (Specification 6360) Decision 1. Final. Version 1.0 General Certificate of Education (A-level) June 2011 Mathematics MD01 (Specification 6360) Decision 1 Final Mark Scheme Mark schemes are prepared by the Principal Examiner and considered, together

More information

Key dates in the examination cycle, 2018/2019

Key dates in the examination cycle, 2018/2019 Produced on behalf of: AQA, CCEA, OCR, Pearson and WJEC Key dates in the examination cycle, 2018/2019 There are key dates for the main examination series of GCSE, GCE and Project qualifications which are

More information

TMCH Report March February 2017

TMCH Report March February 2017 TMCH Report March 2013 - February 2017 Contents Contents 2 1 Trademark Clearinghouse global reporting 3 1.1 Number of jurisdictions for which a trademark record has been submitted for 3 2 Trademark Clearinghouse

More information

DEFINITIVE ANNUAL REPORT Trace elements 2014

DEFINITIVE ANNUAL REPORT Trace elements 2014 EXPERTISE, SERVICE PROVISION AND CUSTOMER RELATIONS QUALITY OF MEDICAL LABORATORIES CLINICAL BIOLOGY COMMISSION COMMITTEE OF EXPERTS EXTERNAL QUALITY ASSESSMENT IN CLINICAL BIOLOGY DEFINITIVE ANNUAL REPORT

More information

SPAREPARTSCATALOG: CONNECTORS SPARE CONNECTORS KTM ART.-NR.: 3CM EN

SPAREPARTSCATALOG: CONNECTORS SPARE CONNECTORS KTM ART.-NR.: 3CM EN SPAREPARTSCATALOG: CONNECTORS ART.-NR.: 3CM3208201EN CONTENT SPARE CONNECTORS AA-AN SPARE CONNECTORS AO-BC SPARE CONNECTORS BD-BQ SPARE CONNECTORS BR-CD 3 4 5 6 SPARE CONNECTORS CE-CR SPARE CONNECTORS

More information

Developments in harmonised scoring systems and data presentation 'The ABC of EQA

Developments in harmonised scoring systems and data presentation 'The ABC of EQA UK NEQAS UK NEQAS FOR CLINICAL CHEMISTRY UNITED KINGDOM NATIONAL EXTERNAL QUALITY ASSESSMENT SCHEMES Developments in harmonised scoring systems and data presentation 'The ABC of EQA Dr David G Bullock

More information

CERTIFICATE IN LUXEMBOURG COMPANY SECRETARIAL & GOVERNANCE PRACTICE

CERTIFICATE IN LUXEMBOURG COMPANY SECRETARIAL & GOVERNANCE PRACTICE CERTIFICATE IN LUXEMBOURG COMPANY SECRETARIAL & GOVERNANCE PRACTICE POLICY ILA asbl 19, rue de Bitbourg L-1273 Luxembourg TABLE OF CONTENTS Program Entry 3 Eligibility criteria 3 Training program 4 Application

More information

Coursework and Controlled Assessment Timetable

Coursework and Controlled Assessment Timetable Coursework and Controlled Assessment Timetable 2017-2018 Coursework () Although some subjects dedicate class time to modular coursework it is mainly written work produced by the student independently and

More information

TEST REPORT : SCENTCO LIMITED. : China : USA, EU, ASIA. : 16-May EN71 Part 3:2013 Migration of Certain Elements Pass

TEST REPORT : SCENTCO LIMITED. : China : USA, EU, ASIA. : 16-May EN71 Part 3:2013 Migration of Certain Elements Pass TEST REPORT Page : 1 of 10 APPLICANT ADDRESS : SCENTCO LIMITED : RM 401, 4/F, SUNG KEE IND. BLDH., 18 KWAI TING ROAD, KWAI CHUNG, N.T., HONG KONG SAMPLE DESCRIPTION VENDOR COUNTRY OF ORIGIN COUNTRY OF

More information

SPARE CONNECTORS KTM 2014

SPARE CONNECTORS KTM 2014 SPAREPARTSCATALOG: // ENGINE ART.-NR.: 3208201EN CONTENT CONNECTORS FOR WIRING HARNESS AA-AN CONNECTORS FOR WIRING HARNESS AO-BC CONNECTORS FOR WIRING HARNESS BD-BQ CONNECTORS FOR WIRING HARNESS BR-CD

More information

Experiences from CRYRING diagnostics

Experiences from CRYRING diagnostics Workshop on Low Current, Low Energy Beam Diagnostics November 23-25 th 2009, Groβsachsen, Germany Experiences from CRYRING diagnostics A. Källberg Manne Siegbahn Laboratory Stockholm University Frescativägen

More information

VQA PROFICIENCY TESTING INVESTIGATION REPORT PROCEDURE

VQA PROFICIENCY TESTING INVESTIGATION REPORT PROCEDURE VQA PROFICIENCY TESTING INVESTIGATION REPORT PROCEDURE 1. Purpose 1.1. This procedure will establish the process for identifying, tracking, completing and investigating the existence of problems that result

More information

Liquid and solid lasers for optimum performance of the Resonance Ionization Laser Ion Source at ISOLDE/CERN

Liquid and solid lasers for optimum performance of the Resonance Ionization Laser Ion Source at ISOLDE/CERN Liquid and solid lasers for optimum performance of the Resonance Ionization Laser Ion Source at ISOLDE/CERN V.N. Fedosseev, CERN, EN department Workshop on Low-Energy Radioactive Isotope Beam (RIB) Production

More information

Using the Bruker Tracer III-SD Handheld X-Ray Fluorescence Spectrometer using PC Software for Data Collection

Using the Bruker Tracer III-SD Handheld X-Ray Fluorescence Spectrometer using PC Software for Data Collection Using the Bruker Tracer III-SD Handheld X-Ray Fluorescence Spectrometer using PC Software for Data Collection Scott A Speakman, Ph.D Center for Materials Science and Engineering at MIT For assistance in

More information

Enterprise Design Objectives: Complexity and Change

Enterprise Design Objectives: Complexity and Change Introduction Enterprise Architecture Enterprise Design Objectives: Complexity and Change Enterprise Architecture presently appears to be a grossly misunderstood concept among management. It is NOT an Information

More information

Using Excel for Graphical Analysis of Data

Using Excel for Graphical Analysis of Data EXERCISE Using Excel for Graphical Analysis of Data Introduction In several upcoming experiments, a primary goal will be to determine the mathematical relationship between two variable physical parameters.

More information

TEST REPORT MATERIAL SUBMITTED IMPORTER COMPANY MODEL NO SUPPLIER REFERENCE BUYER : : : :

TEST REPORT MATERIAL SUBMITTED IMPORTER COMPANY MODEL NO SUPPLIER REFERENCE BUYER : : : : TEST REPORT AB-0505-T MATERIAL SUBMITTED IMPORTER COMPANY MODEL NO SUPPLIER REFERENCE BUYER LAB LOCATIONTURKEY LAB NO. (7217)265-0049 SERVICE TYPE Regular DATE IN September 22 th, 2017 DATE OUT October

More information

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE 1 of 6 List of Topics Covered in this Item: Primary and Secondary Accreditation...1 Personnel...2 Fields of Accreditation...2 Interim Accreditation...3 Notification and Reporting...3 Corrective Actions

More information

Micro-Detective. Ultra-Light, High-Fidelity Hand-Held Radioisotope Identifier

Micro-Detective. Ultra-Light, High-Fidelity Hand-Held Radioisotope Identifier Ultra-Light, High-Fidelity Hand-Held Radioisotope Identifier Accurate nuclide identification based on high resolution gamma spectroscopy with confirmatory neutron detection. Definitive detection of illicit

More information

Graphical Analysis of Data using Microsoft Excel [2016 Version]

Graphical Analysis of Data using Microsoft Excel [2016 Version] Graphical Analysis of Data using Microsoft Excel [2016 Version] Introduction In several upcoming labs, a primary goal will be to determine the mathematical relationship between two variable physical parameters.

More information

EU Declaration of Conformity

EU Declaration of Conformity EU Declaration of Conformity RoHS, REACH and Low Halogen Declaration of Conformity for Seagate CONSTELLATION ES.3 Family of Hard Drives 1. No. 0301131216 2. Name and Address of Manufacturer Koolhovenlaan

More information

Using Excel for Graphical Analysis of Data

Using Excel for Graphical Analysis of Data Using Excel for Graphical Analysis of Data Introduction In several upcoming labs, a primary goal will be to determine the mathematical relationship between two variable physical parameters. Graphs are

More information

Guidance for the format and content of the final study report of non-interventional post-authorisation safety studies

Guidance for the format and content of the final study report of non-interventional post-authorisation safety studies 23 January 2013 EMA/48663/2013 Patient Health Protection Guidance for the format and content of the final study report of non-interventional post-authorisation safety studies Introduction From 10 January

More information

Technical Qualifications How to book assessments

Technical Qualifications How to book assessments Technical Qualifications How to book assessments Version 2.0 August 2018 Technicals and Moderation Support 1 Contents 2 Introduction This guide provides you with all the information you need when booking

More information

271 Health Care Eligibility Benefit Inquiry Response Educational Guide

271 Health Care Eligibility Benefit Inquiry Response Educational Guide 271 Health Care Eligibility Benefit Inquiry Response Educational Guide June 2010 - Version 1.1 Disclaimer INGENIX is still under development stages and frequent changes within this document are expected.

More information

https://support.industry.siemens.com/cs/ww/en/view/

https://support.industry.siemens.com/cs/ww/en/view/ Support Packages for TIA Portal V13 March 2018 https://support.industry.siemens.com/cs/ww/en/view/72341852 Siemens Industry Online Support This entry is from the Siemens Industry Online Support. The general

More information

OIML-CS PD-08 Edition 1

OIML-CS PD-08 Edition 1 PROCEDURAL DOCUMENT OIML-CS PD-08 Edition 1 Signing the OIML-CS Declaration OIML-CS PD-08 Edition 1 ORGANISATION INTERNATIONALE DE METROLOGIE LEGALE INTERNATIONAL ORGANIZATION OF LEGAL METROLOGY Contents

More information

Application for registration of a compost, potting soil product, mulch material, substrate, of degradable pots or technical materials

Application for registration of a compost, potting soil product, mulch material, substrate, of degradable pots or technical materials Will be filled automatically: Please fill in this form electronically and send it directly to by using the Send- Button at the end of the form. Sending the forms via letter post is not necessary. Please

More information

GammaUser2014 Spectrum Analysis Exercise

GammaUser2014 Spectrum Analysis Exercise GammaUser2014 Spectrum Analysis Exercise Seppo Klemola Exercise (rather than intercomparison): Analysis of radionuclides and their concentrations in (legacy) air filter spectrum Spectrum provided for analysis

More information

Error Analysis, Statistics and Graphing

Error Analysis, Statistics and Graphing Error Analysis, Statistics and Graphing This semester, most of labs we require us to calculate a numerical answer based on the data we obtain. A hard question to answer in most cases is how good is your

More information

ph/water Quality Meter F-7X High-spec Command Reference

ph/water Quality Meter F-7X High-spec Command Reference CODE:GZ0000438936 February, 2016 ph/water Quality Meter F-7X High-spec Command Reference 2016 HORIBA, Ltd. Preface This manual describes the communication command list of the ph/water Quality Meters with

More information

Procedure for the Selection, Training, Qualification and Authorisation of Marine Management Systems Auditors

Procedure for the Selection, Training, Qualification and Authorisation of Marine Management Systems Auditors (Rev.0 July 2009) (Rev.1 Sep 2012) (Rev.2 Nov 2014) Procedure for the Selection, Training, Qualification and Authorisation of Marine Management Systems Auditors Note: 1. This procedural requirement applies

More information

The NELAC Institute (TNI) P.O. Box 2439 Weatherford, TX

The NELAC Institute (TNI) P.O. Box 2439 Weatherford, TX SOP TITLE: SOP NO.: 4-107 REVISION NO: 1 (Provisional) Committee: PT Program Executive Committee Approved Date: 11-21-13 Program Executive Committee: PT Program Executive Committee Approved Date: 11-21-13

More information

HESES18A submitting the workbook and data verification

HESES18A submitting the workbook and data verification HESES18A submitting the workbook and data verification Jon Baker Funding Round Adviser Friends House, London 04 September 2018 HESES process timeline Date October 2018 From late November 2018 Activity

More information

October 1, 2017 MPEG-2 Systems Attachment 1 Page 1 of 7. GE Technology Development, Inc. MY A MY MY A.

October 1, 2017 MPEG-2 Systems Attachment 1 Page 1 of 7. GE Technology Development, Inc. MY A MY MY A. October 1, 2017 MPEG-2 Systems Attachment 1 Page 1 of 7 GE Technology Development, Inc. MY 118172-A MY 128994 1 MY 141626-A Thomson Licensing MY 118734-A PH 1-1995-50216 US 7,334,248 October 1, 2017 MPEG-2

More information

The United Nations Crime Trends Survey (UN-CTS) Michael Jandl Statistics and Surveys Section UNODC

The United Nations Crime Trends Survey (UN-CTS) Michael Jandl Statistics and Surveys Section UNODC The United Nations Crime Trends Survey (UN-CTS) Michael Jandl Statistics and Surveys Section UNODC United Nations Survey of Crime Trends and Operations of Criminal Justice Systems (UN-CTS) Started in 1977,

More information

INAB Mandatory and Guidance Documents Policy and Index

INAB Mandatory and Guidance Documents Policy and Index INAB Mandatory and Guidance s Policy and Index This publication is aimed at assisting in determining what documents are relevant to various organisations and at providing contact points for accessing such

More information

NEWCASTLE CLINICAL TRIALS UNIT STANDARD OPERATING PROCEDURES

NEWCASTLE CLINICAL TRIALS UNIT STANDARD OPERATING PROCEDURES SOP details SOP title: Protocol development SOP number: TM 010 SOP category: Trial Management Version number: 03 Version date: 16 December 2016 Effective date: 16 January 2017 Revision due date: 16 January

More information

INAB Mandatory and Guidance Documents Policy and Index

INAB Mandatory and Guidance Documents Policy and Index INAB Mandatory and Guidance s Policy and Index This publication is aimed at assisting in determining what documents are relevant to various organisations and at providing contact points for accessing such

More information

Revised November EFESC Handbook

Revised November EFESC Handbook Revised November 2015 EFESC Handbook 1 Table of Contents EFESC Handbook... 1 Table of Contents... 2 Handbook EFESC... 4 1 Background and objectives... 4 1.1 Sectoral developments... 4 1.1 Objectives...

More information

GCSE MARKING SCHEME SUMMER 2017 GCSE (NEW) MATHEMATICS - UNIT 2 (HIGHER) 3300U60-1. WJEC CBAC Ltd.

GCSE MARKING SCHEME SUMMER 2017 GCSE (NEW) MATHEMATICS - UNIT 2 (HIGHER) 3300U60-1. WJEC CBAC Ltd. GCSE MARKING SCHEME SUMMER 07 GCSE (NEW) MATHEMATICS - UNIT (HIGHER) 00U60- WJEC CBAC Ltd. INTRODUCTION This marking scheme was used by WJEC for the 07 examination. It was finalised after detailed discussion

More information

FAQs: Quality Systems Manual (QSM) Version 5.0

FAQs: Quality Systems Manual (QSM) Version 5.0 General FAQs: Quality Systems Manual (QSM) Version 5.0 1. Why was client changed to "customer" and "documents" to "records" throughout the QSM? The changes were due to ISO requirements, but in general

More information

MAWA Forum State of Play. Cooperation Planning & Support Henk Corporaal MAWA Forum Chair

MAWA Forum State of Play. Cooperation Planning & Support Henk Corporaal MAWA Forum Chair MAWA Forum State of Play Cooperation Planning & Support Henk Corporaal MAWA Forum Chair Content Background MAWA Initiative Achievements and Status to date Future Outlook 2 Background MAWA Initiative The

More information

KEY DATES. 2 Key Dates

KEY DATES. 2 Key Dates KEY DATES 3 Key s Introduction 4. Entry deadlines for 07 8 4. Late entry fees explained 5.3 Late cash-in fees 5.4 Refunds 5.5 Coursework, controlled assessment and non-examination assessment (NEA) mark

More information

IPC REVISION WORKING GROUP. Fourteenth Session Geneva, November 21 to 25, 2005

IPC REVISION WORKING GROUP. Fourteenth Session Geneva, November 21 to 25, 2005 ORIGINAL: English DATE: December 9, 2005 E WORLD INTELLECTUAL PROPERTY ORGANIZATION GENEVA SPECIAL UNION FOR THE INTERNATIONAL PATENT CLASSIFICATION (IPC UNION) IPC REVISION WORKING GROUP Fourteenth Session

More information

Administrative Support Guide GCE Orals. Chinese 6CN01 Summer 2014 GCE

Administrative Support Guide GCE Orals. Chinese 6CN01 Summer 2014 GCE Administrative Support Guide GCE Orals GCE Chinese 6CN0 Summer 0 Pearson Qualification Services Registered in England and Wales No. 96750 Registered Office: One90 High Holborn, London WCV 7BH This handbook

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2014-11-25 Page 1 of 22 Report Reference # E186249-A273-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: UL 60950-1, 2nd Edition, 2014-10-14 (Information Technology

More information

Metal alloy proficiency testing program

Metal alloy proficiency testing program quality control laboratory compliance accreditation performance monitoring method validation quality control laboratory compliance Metal alloy proficiency testing program LGC Quality ISO Guide 34 GMP/GLP

More information

BTEC Centre Guide to Standards Verification

BTEC Centre Guide to Standards Verification BTEC Centre Guide to Standards Verification 2017-2018 Contents Introduction How to use this guide 1. What you need to do 2. What you need to know Standards verification 1. Allocation of your Standards

More information

Edexcel IAL Registration Information January 2016 Session

Edexcel IAL Registration Information January 2016 Session Entry Requirements and Procedures: You need to submit the following Edexcel IAL 1. EDEXCEL Entry Form. 2. Registration fees. Fees can be paid in cash or by card. 3. Photocopy of your valid passport and

More information

An Overview of Proficiency Testing in Sensory Analysis Chantal Gilbert

An Overview of Proficiency Testing in Sensory Analysis Chantal Gilbert An Overview of Proficiency Testing in Sensory Analysis Chantal Gilbert Slide 1 Outline What is proficiency testing? Adapting proficiency testing to Sensory Measurement criteria for panel proficiency Ranking

More information

DNSSEC Workshop. Dan York, Internet Society ICANN 53 June 2015

DNSSEC Workshop. Dan York, Internet Society ICANN 53 June 2015 DNSSEC Workshop Dan York, Internet Society ICANN 53 June 2015 First, a word about our host... 2 Program Committee Steve Crocker, Shinkuro, Inc. Mark Elkins, DNS/ZACR Cath Goulding, Nominet Jean Robert

More information

APPENDIX C. Chain of Custody Forms

APPENDIX C. Chain of Custody Forms APPENDX C Chain of Custody Forms CHAN OF CUSTODY Servkes AE,rpo OWdL 1317 South 13th Ave. Kelso, WA 98626 (360> 5777222 (800) 6957222x07 FAX (360) 6361068 SR#: PAGE _ OF 000# PROJECT NAME,'r j PROJECTNMBER

More information

PORTAL User Guide Proficiency Online Reporting and Trend AnaLysis

PORTAL User Guide Proficiency Online Reporting and Trend AnaLysis PORTAL User Guide Proficiency Online Reporting and Trend AnaLysis https://portal.proficiencytestingschemes.com LGC 1 Chamberhall Business Park Chamberhall Green Bury Lancashire BL9 0AP UK +44(0)161 762

More information

Project Plan: TNI Standard Implementation

Project Plan: TNI Standard Implementation Project Plan: TNI Standard Document: ProjectPlan-NewTNIStandard-11-28-10-v11 # (Include of Review and Action Items) 1 02/12/10 2 01/27/10 QAM Template Subcommittee QS Expert Committee QAM Template Update

More information

Part One of this article (1) introduced the concept

Part One of this article (1) introduced the concept Establishing Acceptance Limits for Uniformity of Dosage Units: Part Two Pramote Cholayudth The concept of sampling distribution of acceptance value (AV) was introduced in Part One of this article series.

More information

The physical connection to the G68 Surround Controller consists of a Null Modem / RS232C cable.

The physical connection to the G68 Surround Controller consists of a Null Modem / RS232C cable. G68 System RS232 Commands This document provides relevant RS232 commands for the Meridian G68 Surround Controller. All basic commands take the form of two ASCII characters followed by a carriage return

More information

Candidate Brochure. V15.1a. American Society of Professional Estimators 2525 Perimeter Place Dr., Ste. 103 Nashville, TN 37214

Candidate Brochure. V15.1a. American Society of Professional Estimators 2525 Perimeter Place Dr., Ste. 103 Nashville, TN 37214 Candidate Brochure American Society of Professional Estimators 2525 Perimeter Place Dr., Ste. 103 Nashville, TN 37214 615.316.9200 Fax 615.316.9800 ACCE Recognized Program V15.1a Revised V15.1a May 2017

More information

LoGA: Low-Overhead GPU Accounting Using Events

LoGA: Low-Overhead GPU Accounting Using Events 10th ACM International Systems and Storage Conference, (KIT) KIT The Research University in the Helmholtz Association www.kit.edu GPU Sharing GPUs increasingly popular in computing Not every application

More information

Quality and Safety of Medicines

Quality and Safety of Medicines Falsified lamivudine/zidovudine/nevirapine tablets: rapid identification using X-ray fluorescence technique The X-ray fluorescence (XRF) technique was used to determine bromine (Br) concentration in lamivudine/zidovudine/nevirapine

More information

NIAC Membership Application Checklists

NIAC Membership Application Checklists NIAC Membership Application Checklists Thank you for your interest in joining NIAC. To ensure the NIAC membership requirements are met, please review your processes for qualifying lead auditors and performing

More information

Application for registration of a compost, potting soil product, mulch material, substrate, of degradable pots or technical materials

Application for registration of a compost, potting soil product, mulch material, substrate, of degradable pots or technical materials Will be filled automatically: Please fill in this form electronically and send it directly to by using the Send- Button at the end of the form. Sending the forms via letter post is not necessary. Please

More information

The physical connection to the 861 Reference System consists of a Null Modem / RS232C cable.

The physical connection to the 861 Reference System consists of a Null Modem / RS232C cable. This document provides relevant RS232 commands for the Meridian 861 Surround Processor. All basic commands take the form of two ASCII characters followed by a carriage return to execute. Once a basic command

More information

Document valide au 21/08/2015. Welcome Booklet

Document valide au 21/08/2015. Welcome Booklet Welcome Booklet Welcome to Bipea! You have chosen to join our Proficiency Testing Programs. We thank you for your trust! We hope that our Proficiency Testing Schemes will fully meet your needs and requirements.

More information

Technical Note TN15. G68 RS232 Interface. 5 th January Source Commands. Volume Commands

Technical Note TN15. G68 RS232 Interface. 5 th January Source Commands. Volume Commands Technical Note TN15 5 th January 2009 G68 RS232 Interface The RS232 interface for the G68 can be operated from any terminal which operates at 9600 baud with 1 start bit, 1 stop bit and 0 parity. Commands

More information

Journal of American Science 2014;10(2)

Journal of American Science 2014;10(2) LABVIEW Real Time Control for Pneumatic Transfer System in TRIGA Research Reactor Adel A.M. Abdelrahman Metallurgy Department, Nuclear Research Center, Atomic Energy Authority, Egypt elthakeel@yahoo.com

More information

The main objective is to respond to an increasing need for coordination since there is a close relationship among multiple ISO security standards proj

The main objective is to respond to an increasing need for coordination since there is a close relationship among multiple ISO security standards proj TMB 42/2014(REV1) June 2014 STRATEGIC AND POLICY ISSUES Agenda item 5.5 STRATEGIC ISSUES RELATED TO STRUCTURES Items for decision. 1. Task force on the security sector Items for information 2. SAG-E report

More information

Hitachi-GE Nuclear Energy, Ltd. UK ABWR GENERIC DESIGN ASSESSMENT Resolution Plan for RO-ABWR-0027 Hardwired Back Up System

Hitachi-GE Nuclear Energy, Ltd. UK ABWR GENERIC DESIGN ASSESSMENT Resolution Plan for RO-ABWR-0027 Hardwired Back Up System Hitachi-GE Nuclear Energy, Ltd. UK ABWR GENERIC DESIGN ASSESSMENT Resolution Plan for RO-ABWR-0027 Hardwired Back Up System RO TITLE: Hardwired Back Up System REVISION : 5 Overall RO Closure Date (Planned):

More information

Accreditation Body Evaluation Procedure for AASHTO R18 Accreditation

Accreditation Body Evaluation Procedure for AASHTO R18 Accreditation Accreditation Body Evaluation Procedure for AASHTO R18 Accreditation Final August 9, 2016 Page 1 of 12 Section Number Table of Contents Title of Section 0 Purpose 1 Scope 2 References 3 Objectives 4 Criteria

More information

DEVELOPMENT OF A PROCEDURE FOR ROUTE SEGMENTATION USING PREDICTED LAYER THICKNESSES FROM RADAR MEASUREMENTS

DEVELOPMENT OF A PROCEDURE FOR ROUTE SEGMENTATION USING PREDICTED LAYER THICKNESSES FROM RADAR MEASUREMENTS DEVELOPMENT OF A PROCEDURE FOR ROUTE SEGMENTATION USING PREDICTED LAYER THICKNESSES FROM RADAR MEASUREMENTS FLORIDA DOT STATE PROJECT 99700-7550, PHASE 2A FINAL REPORT PREPARED BY: EMMANUEL G. FERNANDO,

More information

BTEC Centre Guide to Standards Verification

BTEC Centre Guide to Standards Verification BTEC Centre Guide to Standards Verification 2016-2017 Contents Introduction How to use this guide 1. What you need to do 2. What you need to know Standards verification 1. Allocation of your Standards

More information

Release Notes: Thermo-Calc Software Package Version 2018a

Release Notes: Thermo-Calc Software Package Version 2018a Release Notes: Thermo-Calc Software Package Version 2018a 2018 Foundation of Computational Thermodynamics: Solna, Sweden Contents Release notes Thermo-Calc 2018a 2 Highlights 2 Software Development Kits

More information

Specification for TRAN Layer Services

Specification for TRAN Layer Services Specification for TRAN Layer Services Version 1.0 November 3, 1995 Sponsored by: Architecture Working Group of the 1394 Trade Association Approved for Release by: 1394 Trade Association Steering Committee

More information

Hitachi-GE Nuclear Energy, Ltd. UK ABWR GENERIC DESIGN ASSESSMENT Resolution Plan for RO-ABWR-0028 Safety System Logic & Control (SSLC) Class 1 HMI

Hitachi-GE Nuclear Energy, Ltd. UK ABWR GENERIC DESIGN ASSESSMENT Resolution Plan for RO-ABWR-0028 Safety System Logic & Control (SSLC) Class 1 HMI Hitachi-GE Nuclear Energy, Ltd. UK ABWR GENERIC DESIGN ASSESSMENT Resolution Plan for RO-ABWR-0028 Safety System Logic & Control (SSLC) Class 1 HMI RO TITLE: Safety System Logic & Control (SSLC) Class

More information