Safety Instructions Levelflex FMP50/51/52/53/54/55/56/57
|
|
- Eleanore Allen
- 6 years ago
- Views:
Transcription
1 XA00531F-D/00/EN/ Products Solutions Services Safety Instructions FMP50/51/52/53/54/55/56/ ma HART Control Drawing IS Document: XA00531F-D Safety instructions for electrical apparatus for explosion-hazardous areas
2 XA00531F-D 2 Endress+Hauser
3 XA00531F-D FMP50/51/52/53/54/55/56/ ma HART Table of Contents Associated Documentation Extended order code Combined type of protection (Approval code, 8A) Safety instructions: General Safety instructions: Special conditions Safety instructions: Installation Intrinsic safety Class I, Div. 2, Groups A-D Process Seals Connection data Temperature tables Endress+Hauser 3
4 XA00531F-D Associated Documentation This document is an integral part of the following Operating Instructions: BA01000F/00 (FMP50), BA01001F/00 (FMP51/52/54), BA01002F/00 (FMP53), BA01003F/00 (FMP55), BA01004F/00 (FMP56/57) The Operating Instructions pertaining to the device apply. Extended order code The extended order code is indicated on the nameplate, which is affixed to the device in such a way that it is clearly visible. Additional information about the nameplate is provided in the associated Operating Instructions. Structure of the extended order code FMP5x - ************* + A*B*C*D*E*F*G* Device type Basic specifications Optional specifications * = Placeholder At this position, an option (number or letter) selected from the specification is displayed instead of the placeholders. Basic specifications The features that are absolutely essential for the device (mandatory features) are specified in the basic specifications. The number of positions depends on the number of features available. The selected option of a feature can consist of several positions. Optional specifications The optional specifications describe additional features for the device (optional features). The number of positions depends on the number of features available. The features have a 2-digit structure to aid identification (e.g. JA). The first digit (ID) stands for the feature group and consists of a number or a letter (e.g. J = test, certificate). The second digit constitutes the value that stands for the feature within the group (e.g. A = 3.1 material (wetted parts), inspection certificate). More detailed information about the device is provided in the following tables. These tables describe the individual positions and IDs in the extended order code which are relevant to hazardous locations. Device type: FMP50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57 Basic specifications Position Selected option Description 1, 2 Approval FMP5x FA FM C/US IS Cl. I, Div. 1, Groups A-D Cl. I, Zone 0, AEx ia/ex ia IIC FB 8A FM C/US IS Cl. I, II, III, Div. 1, Groups A-G Cl. I, Zone 0, AEx ia/ex ia IIC; NI Cl. I, Div. 2, Groups A-D FM/CSA IS + XP-AIS Cl. I, Div. 1, Groups A-D DIP Cl. II, III, Div. 1, Groups E-G 3 Power Supply; Output FMP5x A 2-wire, 4-20 ma HART B 2-wire; 4-20 ma HART, switch output (PFS) C 2-wire; 4-20 ma HART, 4 20 ma 4 Display; Operation FMP5x A Without, via communication C SD02, 4-line, push buttons + data backup function E SD03, 4-line, illum., touch control + data backup function L M Prepared for display FHX50 + M12 connection Prepared for display FHX50 + custom connection 4 Endress+Hauser
5 XA00531F-D 5 Housing FMP5x A* 1 GT19 dual compartment, plastics PBT C GT20 dual compartment, Alu coated FMP51/52/54-57 B GT18 dual compartment, 316L 9, 10 Seal FMP50 A1 Viton, C FMP51 A4 Viton, C B3 EPDM, C C3 Kalrez, C E1 FVMQ, C FMP53 AD FKM, FDA, USP Cl. VI, C B5 EPDM, FDA, USP Cl. VI, C C4 Kalrez, FDA, USP Cl. VI, C FMP54 D1 Graphite, C (XT) D2 Graphite, C (HT) FMP56 AB Viton, C B3 EPDM, C FMP57 A4 Viton, C B3 EPDM, C C5 Kalrez, C * 1 Only with approval FA Optional specifications ID Selected option Description Mx Probe Design FMP5x MB Sensor remote, 3 m/9 ft cable, detachable + mounting bracket FMP53 MA Sensor compact, detachable FMP50-54/56/57 MC Sensor remote, 6 m/18 ft cable, detachable + mounting bracket MD Sensor remote, 9 m/27 ft cable, detachable + mounting bracket Nx Accessory Mounted FMP5x NA Overvoltage protection FMP51/52/55 NC Gas-tight feed through Combined type of protection (Approval code, 8A) Devices with approval code "8A" are suitable for installation with explosion protection type of Intrinsic Safety or Explosionproof. Before initial commissioning of the device, the type of protection used must be specified and indicated on the nameplate as outlined below. It is not permitted to change the type of protection after initial commissioning as this can jeopardize the explosion protection. For aluminum housings: Void out the explosion protection that is not used on the nameplate. For stainless steel housings: Using a striking tool, mark the explosion protection used, or void out the explosion protection that is not used. Endress+Hauser 5
6 XA00531F-D IP68 / 66 Type 4X / 6P Encl. CRN OF C C US CSA IS CL I, II, III, DIV 1, GP A-G T6-T1 XP-AIS CL I, DIV 1, GP A-D T6-T1 DIP CL II, III, DIV 1, GP E-G Nameplate " Caution! It is critical to observe and follow the correct instructions for installation depending on the type of protection used. Refer to the following table for reference to the correct installation instructions. Type of protection Agency approval Control Drawing no. / Document no. Intrinsic Safety CSA XA00530F FM XA00531F Explosionproof CSA XA00529F FM XA00532F Class I, Division 2 installation: References in this manual to Class I, Division 2 installation are not applicable for devices with the combined type of protection. For installation in Class I, Division 2, these devices must be installed per the applicable Division 1 intrinsic safety or explosionproof requirements. Safety instructions: General Staff must meet the following conditions for mounting, electrical installation, commissioning and maintenance of the device: Be suitably qualified for their role and the tasks they perform Be trained in explosion protection Be familiar with national regulations Install the device according to the manufacturer's instructions and national regulations. Do not operate the device outside the specified electrical, thermal and mechanical parameters. Only use the device in media to which the wetted materials have sufficient durability. Avoid electrostatic charging: Of plastic surfaces (e.g. housing, sensor element, special varnishing, attached additional plates,..) Of isolated capacities (e.g. isolated metallic plates) Refer to the temperature tables for the relationship between the permitted ambient temperature for the sensor and/or transmitter, depending on the range of application, and the temperature class. Modifications to the device can affect the explosion protection and must be carried out by staff authorized to perform such work by Endress+Hauser. Safety instructions: Special conditions Permitted ambient temperature range at the electronics housing: 40 C T a +80 C. Observe the information in the temperature tables. Use supply wires suitable for 20 K above the ambient temperature. Electrostatic/impact sparks Warning: Avoid electrostatic charging of the plastic surfaces, for plastic process connections or plastic coatings. Warning: Install the device to exclude impact and friction sparks on the aluminum housing. Device type FMP52, FMP55, FMP56, FMP57 The probes (rod and rope) with plastic coated surfaces can be electrostatically charged. 6 Endress+Hauser
7 XA00531F-D Safety instructions: Installation A B C å 1 A Class I, Div. 1, Groups A, B, C, D; Zone 0; Class II, Div. 1, Groups E, F, G, Class III B Zone 1 C Zone 0 1 Output 4-20 ma HART 2 Output PFS passive or output 4 to 20 ma passive 3 Barrier / associated equipment 4 External load 5 Loop 6 4 to 20 ma 7 Supply 8 Ground stud 9 Remote cable 10 Flanges acc. international standards DN , resp. 1½" to 8" 11 Tri-Clamp 2" FMP52/55/56/57: fully insulated versions / plastic coated probes 12 Tri-Clamp 1½" 13 G/NPT ¾", G/NPT 1½" 14 Process adapter for welding coupling (e.g. Endress+Hauser UNI) Option: Interconnection with FM-approved service interface Commubox FXA291 from Endress+Hauser. FMP5x_CSA+FM_06 Endress+Hauser 7
8 XA00531F-D Intrinsic safety Intrinsically safe, Class I, Div. 1, Groups A, B, C, D, Class II, Div. 1, Groups E, F, G, Class III Class I, Zone 0 or Zone 1, AEx ia IIC/Ex ia IIC Entity installation Use a FM-approved intrinsic safety barrier or other associated equipment that satisfies the following conditions: U o (V oc ) U i (V max ), I o (I sc ) I i (I max ), C o (C a ) C i + C cable, L o (L a ) L i + L cable and P o P i. For transmitter parameters: 9, "Connection data" section. Control room equipment may not use or generate over 250 V rms. Install as per National Electrical Code (NFPA70) or Canadian Electrical Code, Part I (C22.1), as applicable. Warning: Substitution of components may impair intrinsic safety. Always follow the installation drawing provided by the intrinsic safety barrier manufacturer when installing this equipment. The configuration of the intrinsic safety barrier(s) must be FM-approved. When prepared for use with remote display FHX50, remote display is intrinsically safe suitable for Class I, Division 1/Zone 0 locations and connection between transmitter housing and remote display is intrinsically safe field wiring. For Class II and III Keep cover tight unless power has been switched off. Class I, Div. 2, Groups A-D Only for device type FMP5x, Basic specification, Position 1, 2 (Approval) = FB Device type FMP5x, Basic specification, Position 1, 2 (Approval) = FA and 8A are not marked for use in Class I, Division 2; however, these devices are suitable for this application when installed using the intrinsic safety instructions for Class I, Division 1. Nonincendive Field Wiring (NIFW) installation The Nonincendive Field Wiring circuit concept allows interconnection of nonincendive field wiring apparatus with associated nonincendive field wiring apparatus or associated apparatus not specifically examined in combination as a system using any of the wiring methods permitted for unclassified locations, when the following conditions are met: V max V oc or V t, C a C i + C cable, L a L i + L cable. For transmitter parameters: 9, "Connection data" section. The transmitter provides a current controlled circuit; therefore, the parameter I max is not required and need not to be aligned with I sc and I t of the associated nonincendive field wiring apparatus or associated apparatus. Control room equipment may not use or generate over 250 V rms. Install per National Electrical Code (NFPA 70) or Canadian Electrical Code, Part I (C22.1), as applicable. Warning: Substitution of components may impair suitability for Class I, Div. 2. Always follow the installation drawing provided by the associated apparatus manufacturer. The configuration of the associated apparatus must be FM-approved. Device type FMP5x, Basic specification, Position 3 (Power Supply; Output) = A Probe is suitable for installation in Class I, Division 2 only when using this wiring method. If probe is installed in a location classified as Class I, II, III, Divison 1/Zone 0, supply must be connected to associated apparatus per the intrinsic safety instructions above. When prepared for use with remote display FHX50, remote display is suitable for Class I, Division 2 locations only and connection between transmitter housing and remote display is nonincendive field wiring. If associated apparatus is used per the intrinsic safety instructions above, remote display is suitable for Class I, Division 1/Zone 0 locations and connection between transmitter housing and remote display is intrinsically safe wiring. Device type FMP5x, Basic specification, Position 3 (Power Supply; Output) = B or C Probe is intrinsically safe, AEx ia/ex ia, and suitable for installation in Class I, II, III, Division 1 or Class I, Zone 0/1. When prepared for use with remote display FHX50, remote display is intrinsically safe suitable for Class I, Division 1/Zone 0 locations and connection between transmitter housing and remote display is intrinsically safe field wiring. 8 Endress+Hauser
9 XA00531F-D Standard Wiring installation (only for NPT conduit entries) Install per the National Electrical Code (NFPA 70) or Canadian Electrical Code, Part I (C22.1), as applicable, using wiring methods appropriate for the location. Associated apparatus not required. For the maximum supply voltage: 9, "Connection data" section. Warning: Explosion hazard - Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous. Warning: Substitution of components may impair suitability for Class I, Div. 2. Device type FMP5x, Basic specification, Position 3 (Power Supply; Output) = A Probe is suitable for installation in Class I, Division 2 only when using this wiring method. If probe is installed in a location classified as Class I, II, III, Divison 1/Zone 0, supply must be connected to associated apparatus per the intrinsic safety instructions above. When prepared for use with remote display FHX50, remote display is suitable for Class I, Division 2 locations only and connection between transmitter housing and remote display is nonincendive field wiring. If associated apparatus is used per the intrinsic safety instructions above, remote display is suitable for Class I, Division 1/Zone 0 locations and connection between transmitter housing and remote display is intrinsically safe wiring. Device type FMP5x, Basic specification, Position 3 (Power Supply; Output) = B or C Probe is intrinsically safe, AEx ia/ex ia, and suitable for installation in Class I, II, III, Division 1 or Class I, Zone 0/1. When prepared for use with remote display FHX50, remote display is intrinsically safe suitable for Class I, Division 1/Zone 0 locations and connection between transmitter housing and remote display is intrinsically safe field wiring. Process seals The following device types are Dual Seal devices per ANSI/ISA and do not require the use of an external secondary process seal: Device type Basic specification, Position 1, 2 (Approval) MWP* Method of annunciation FMP50, FMP53, FMP56, FMP57 8A 6 bars Process fluid leakage through vent located in electronics compartment. FMP51, FMP52, FMP55 FB, 8A 40 bars Electronic firmware is incorporated to detect and signal any significant increases or decreases of measurement signal reflection caused by combustible or flammable process fluid between the primary and secondary seal. FMP54 FB, 8A 370 bars * MWP = Maximum Working Pressure for the Dual Seal rating to be effective and may be a value less than the MWP for the device. Connection data Optional specification, ID Nx (Accessory Mounted) = NA (Overvoltage protection (TRC [16], type OVP10 and TRC [17], type OVP20) When using the internal overvoltage protection: No changes to the connection values. Basic specification, Position 1, 2 (Approval) = FA Basic specification, Position 3 (Power Supply; Output) = A (TRC [21], [31]) IS, Class I, Div. 1; Class I, Zone 0, AEx ia/ex ia Terminal 1 (+), 2 ( ) Power supply: U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 12 nf Endress+Hauser 9
10 XA00531F-D Basic specification, Position 3 (Power Supply; Output) = B (TRC [02], [22]) IS, Class I, Div. 1; Class I, Zone 0, AEx ia/ex ia Terminal 1 (+), 2 ( ) Terminal 3 (+), 4 ( ) Power supply: U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 5 nf Switch output (PFS): U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 3 nf effective inner capacitance to ground C i = 5.28 nf Basic specification, Position 3 (Power Supply; Output) = C (TRC [04]) IS, Class I, Div. 1; Class I, Zone 0, AEx ia/ex ia Terminal 1 (+), 2 ( ) Terminal 3 (+), 4 ( ) Power supply: U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 30 nf Output ma: U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 30 nf Basic specification, Position 1, 2 (Approval) = FB Basic specification, Position 3 (Power Supply; Output) = A (TRC [21], [31]) IS, Class I, II, III, Div. 1; Class I, Zone 0, AEx ia/ex ia Terminal 1 (+), 2 ( ) Power supply: U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 12 nf NIFW: Class I, Div. 2 * Terminal 1 (+), 2 ( ) Power supply: U i = 35 V I i = transmitter is a current controlled device effective inner inductance L i = 0 effective inner capacitance C i = 12 nf * Probe is suitable for installation in Class I, Division 2 only. If probe is installed in a location classified as Class I, Division 1/Zone 0, Terminal 1 (+), 2 ( ) must be connected to associated apparatus with intrinsically safe outputs. 10 Endress+Hauser
11 XA00531F-D Class I, Div. 2 * Terminal 1 (+), 2 ( ) Power supply: Input voltage = 35 V Input current = 22.5 ma * Probe is suitable for installation in Class I, Division 2 only. If probe is installed in a location classified as Class I, Division 1/Zone 0, Terminal 1 (+), 2 ( ) must be connected to associated apparatus with intrinsically safe outputs. Basic specification, Position 3 (Power Supply; Output) = B (TRC [02], [22]) IS, Class I, II, III, Div. 1; Class I, Zone 0, AEx ia/ex ia Terminal 1 (+), 2 ( ) Terminal 3 (+), 4 ( ) Power supply: U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 5 nf Switch output (PFS): U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 3 nf effective inner capacitance to ground C i = 5.28 nf NIFW: Class I, Div. 2 Terminal 1 (+), 2 ( ) Terminal 3 (+), 4 ( ) Power supply: U i = 35 V I i = transmitter is a current controlled device effective inner inductance L i = 0 effective inner capacitance C i = 5 nf Switch output (PFS): U i = 35 V I i = transmitter is a current controlled device effective inner inductance L i = 0 effective inner capacitance C i = 3 nf effective inner capacitance to ground C i = 5.28 nf Class I, Div. 2 Terminal 1 (+), 2 ( ) Terminal 3 (+), 4 ( ) Power supply: Input voltage = 35 V Input current = 22 ma Switch output (PFS): Input voltage = 35 V* P i = 1 W * The power consumption of I/O modules with passive PFS output can be limited for certain applications. Recommended: Power consumption = 1 W. This is obtained for a supply voltage at the terminals of 27 V DC. For higher supply voltages (U max ): Insert a serial resistance (R V ) in order to limit the power consumption table below. Table for the PFS serial resitance (R V ): Power consumption Total power consumption Internal resistance R I 1.0 W 1.88 W 760 Endress+Hauser 11
12 XA00531F-D U max [V] R V min ! Note! For values associated with a higher or lower internal power consumption please contact Endress+Hauser. Basic specification, Position 3 (Power Supply; Output) = C (TRC [04]) IS, Class I, II, III, Div. 1; Class I, Zone 0, AEx ia/ex ia Terminal 1 (+), 2 ( ) Terminal 3 (+), 4 ( ) Power supply: U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 30 nf Output ma: U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 30 nf NIFW: Class I, Div. 2 Terminal 1 (+), 2 ( ) Terminal 3 (+), 4 ( ) Power supply: U i = 30 V I i = transmitter is a current controlled device effective inner inductance L i = 0 effective inner capacitance C i = 30 nf Output ma: U i = 30 V I i = transmitter is a current controlled device effective inner inductance L i = 0 effective inner capacitance C i = 30 nf Class I, Div. 2 Terminal 1 (+), 2 ( ) Terminal 3 (+), 4 ( ) Power supply: Input voltage = 30 V Input current = 22 ma Output ma: Input voltage = 30 V Input current = 22 ma 12 Endress+Hauser
13 XA00531F-D Basic specification, Position 1, 2 (Approval) = 8A Basic specification, Position 3 (Power Supply; Output) = A (TRC [02], [22]) IS, Class I, II, III, Div. 1; Class I, Zone 0, AEx ia/ex ia Terminal 1 (+), 2 ( ) Power supply: U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 5 nf Basic specification, Position 3 (Power Supply; Output) = B (TRC [02], [22]) IS, Class I, II, III, Div. 1; Class I, Zone 0, AEx ia/ex ia Terminal 1 (+), 2 ( ) Terminal 3 (+), 4 ( ) Power supply: U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 5 nf Switch output (PFS): U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 3 nf effective inner capacitance to ground C i = 5.28 nf Basic specification, Position 3 (Power Supply; Output) = C (TRC [04]) IS, Class I, II, III, Div. 1; Class I, Zone 0, AEx ia/ex ia Terminal 1 (+), 2 ( ) Terminal 3 (+), 4 ( ) Power supply: U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 30 nf Output ma: U i = 30 V I i = 300 ma P i = 1 W effective inner inductance L i = 0 effective inner capacitance C i = 30 nf Service interface (CDI) Taking the following values into consideration, the device can be connected to the Endress+Hauser FXA291 service tool or a similar interface: Service interface U i = 7.3 V effective inner inductance L i = negligible effective inner capacitance C i = negligible U o = 7.3 V I o = 100 ma P o = 160 mw L o (mh) = C o (μf) = Endress+Hauser 13
14 XA00531F-D 14 Endress+Hauser
15 XA00531F-D Temperature tables Table of contents General notes Diagram Intrinsically Safe (IS) Probe: Class I, Zone 0 / Class I, Division 1 Electronics housing: Class I, Zone 1 / Class I, Division 1 IS FMP FMP FMP FMP FMP54, Position 9, 10 (Seal) = D FMP54, Position 9, 10 (Seal) = D FMP FMP FMP FMP5x, Optional specification, ID Mx (Probe design) = MB, MC, MD Nonincendive Field Wiring (NIFW) or Standard Division 2 Wiring Probe: Class I, Division 2 Electronics housing: Class I, Division 2 NIFW Div. 2 FMP FMP FMP FMP FMP54, Position 9, 10 (Seal) = D FMP54, Position 9, 10 (Seal) = D FMP FMP FMP FMP5x, Optional specification, ID Mx (Probe Design) = MB, MC, MD Endress+Hauser 15
16 XA00531F-D Nonincendive Field Wiring (NIFW) or Standard Division 2 Wiring Probe: Class I, Zone 0 or Zone 1 / Class I, Division 1 or Division 2 Electronics housing: Class I, Division 2 NIFW Div. 2 FMP FMP FMP FMP FMP54, Position 9, 10 (Seal) = D FMP54, Position 9, 10 (Seal) = D FMP FMP FMP FMP5x, Optional specification, ID Mx (Probe Design) = MB, MC, MD Probe and electronics housing: Class II, III, Division 1 FMP5x Endress+Hauser
17 XA00531F-D General notes! Note! Unless otherwise indicated, the positions always refer to the basic specification. Observe the permitted temperature range at the probe. * 1 = Functional Max. permissible process temperature Selection table Position 1, 2 (Approval) Position 5 (Housing) FA FB 8A FM C/US IS Cl. I, Div. 1, Groups A-D Cl. I, Zone 0, AEx ia/ex ia IIC FM C/US IS Cl. I, II, III, Div. 1, Groups A-G Cl. I, Zone 0, AEx ia/ex ia IIC; NI Cl. I, Div. 2, Groups A-D FM/CSA IS + XP-AIS Cl. I, Div. 1, Groups A-D DIP Cl. II, III, Div. 1, Groups E-G A B C GT19 dual compartment, plastics PBT GT18 dual compartment, 316L GT20 dual compartment, Alu coated Position 3 (Power Supply; Output) Transmission code of the terminal module Channels A B C 2-wire, 4-20 ma HART 2-wire, 4-20 ma HART, switch output (PFS) 2-wire, 4-20 ma HART, ma TRC [21], [31] TRC [02], [22] TRC [04] - 1 or 2 channels used 1 or 2 channels used " Caution! Optional specification, ID Nx (Accessory Mounted) = NA (Overvoltage protection (TRC [16], type OVP10 and TRC [17], type OVP20) When using the internal overvoltage protection: Reduce the admissible ambient temperature at the housing by 2 K. Basic specification, Position 5 (Housing) = A When using the remote display FHX50: Reduce the admissible ambient temperature at the housing by 3 K. Endress+Hauser 17
18 XA00531F-D Diagram Example diagrames to the temperature tables A T a P 1 P 2 P 3 T p P 5 P 4 B T a P 1 P 2 P 3 P 6 P 5 P 4 T p å 2 A Version 1 B Version 2 T a Ambient temperature Process temperature T p Derating 18 Endress+Hauser
19 XA00531F-D Intrinsically Safe (IS) Probe: Class I, Zone 0 / Class I, Division 1 Electronics housing: Class I, Zone 1 / Class I, Division 1 FMP50 Position 3 (Power Supply; Output) = A (TRC [21], [31]) Position 5 (Housing) = A A T6 ( 85 C) 20 C 60 C 60 C 60 C 80 C 54 C 80 C 20 C 20 C 20 C - - A T6 ( 85 C) 20 C 60 C 60 C 60 C 80 C 56 C 80 C 20 C 20 C 20 C - - Position 3 (Power Supply; Output) = B (TRC [02], [22]) Position 5 (Housing) = A B: 1 channel used T6 ( 85 C) 20 C 57 C 57 C 57 C 80 C 53 C 80 C 20 C 20 C 20 C - - B: 2 channels used T6 ( 85 C) 20 C 43 C 43 C 43 C 80 C 37 C 80 C 20 C 20 C 20 C - - B: 1 channel used T6 ( 85 C) 20 C 60 C 60 C 60 C 80 C 56 C 80 C 20 C 20 C 20 C - - B: 2 channels used T6 ( 85 C) 20 C 51 C 51 C 51 C 80 C 49 C 80 C 20 C 20 C 20 C - - Position 3 (Power Supply; Output) = C (TRC [04]) Position 5 (Housing) = A C: 1 channel used T6 ( 85 C) 20 C 60 C 60 C 60 C 80 C 53 C 80 C 20 C 20 C 20 C - - C: 2 channels used T6 ( 85 C) 20 C 52 C 52 C 52 C 80 C 47 C 80 C 20 C 20 C 20 C - - C: 1 channel used T6 ( 85 C) 20 C 60 C 60 C 60 C 80 C 56 C 80 C 20 C 20 C 20 C - - C: 2 channels used T6 ( 85 C) 20 C 54 C 54 C 54 C 80 C 52 C 80 C 20 C 20 C 20 C - - Endress+Hauser 19
20 XA00531F-D Intrinsically Safe (IS) Probe: Class I, Zone 0 / Class I, Division 1 Electronics housing: Class I, Zone 1 / Class I, Division 1 FMP51 Position 3 (Power Supply; Output) = A (TRC [21], [31]) A T6 ( 85 C) 40 C 60 C 60 C 60 C 85 C 52 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 75 C 75 C 75 C 100 C 67 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 80 C 81 C 80 C 135 C 68 C 135 C 40 C 40 C 40 C - - T3 (200 C) 40 C 80 C 81 C 80 C 200 C 49 C 200 C 40 C 40 C 40 C - - A T6 ( 85 C) 40 C 60 C 60 C 60 C 85 C 54 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 75 C 75 C 75 C 100 C 69 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 80 C 81 C 80 C 135 C 70 C 135 C 40 C 40 C 40 C - - T3 (200 C) 40 C 80 C 81 C 80 C 200 C 57 C 200 C 40 C 40 C 40 C - - Position 3 (Power Supply; Output) = B (TRC [02], [22]) B: 1 channel used T6 ( 85 C) 40 C 60 C 60 C 60 C 85 C 52 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 75 C 75 C 75 C 100 C 67 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 80 C 80 C 80 C 135 C 67 C 135 C 40 C 40 C 40 C - - T3 (200 C) 40 C 80 C 80 C 80 C 200 C 49 C 200 C 40 C 40 C 40 C - - B: 2 channels used T6 ( 85 C) 40 C 51 C 51 C 51 C 85 C 43 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 66 C 66 C 66 C 100 C 58 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 75 C 75 C 75 C 135 C 60 C 135 C 40 C 40 C 40 C - - T3 (200 C) 40 C 75 C 75 C 75 C 200 C 45 C 200 C 40 C 40 C 40 C Endress+Hauser
21 XA00531F-D B: 1 channel used T6 ( 85 C) 40 C 60 C 60 C 60 C 85 C 54 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 75 C 75 C 75 C 100 C 69 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 80 C 80 C 80 C 135 C 69 C 135 C 40 C 40 C 40 C - - T3 (200 C) 40 C 80 C 80 C 80 C 200 C 56 C 200 C 40 C 40 C 40 C - - B: 2 channels used T6 ( 85 C) 40 C 51 C 51 C 51 C 85 C 44 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 66 C 66 C 66 C 100 C 59 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 75 C 75 C 75 C 135 C 63 C 135 C 40 C 40 C 40 C - - T3 (200 C) 40 C 75 C 75 C 75 C 200 C 50 C 200 C 40 C 40 C 40 C - - Position 3 (Power Supply; Output) = C (TRC [04]) C: 1 channel used T6 ( 85 C) 40 C 60 C 60 C 60 C 85 C 51 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 75 C 75 C 75 C 100 C 66 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 80 C 80 C 80 C 135 C 68 C 135 C 40 C 40 C 40 C - - T3 (200 C) 40 C 80 C 80 C 80 C 200 C 48 C 200 C 40 C 40 C 40 C - - C: 2 channels used T6 ( 85 C) 40 C 54 C 54 C 54 C 85 C 46 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 69 C 69 C 69 C 100 C 61 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 78 C 78 C 78 C 135 C 64 C 135 C 40 C 40 C 40 C - - T3 (200 C) 40 C 78 C 78 C 78 C 200 C 48 C 200 C 40 C 40 C 40 C - - C: 1 channel used T6 ( 85 C) 40 C 60 C 60 C 60 C 85 C 53 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 75 C 75 C 75 C 100 C 68 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 80 C 80 C 80 C 135 C 70 C 135 C 40 C 40 C 40 C - - T3 (200 C) 40 C 80 C 80 C 80 C 200 C 56 C 200 C 40 C 40 C 40 C - - C: 2 channels used T6 ( 85 C) 40 C 54 C 54 C 54 C 85 C 48 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 69 C 69 C 69 C 100 C 63 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 78 C 78 C 78 C 135 C 66 C 135 C 40 C 40 C 40 C - - T3 (200 C) 40 C 78 C 78 C 78 C 200 C 53 C 200 C 40 C 40 C 40 C - - Endress+Hauser 21
22 XA00531F-D Intrinsically Safe (IS) Probe: Class I, Zone 0 / Class I, Division 1 Electronics housing: Class I, Zone 1 / Class I, Division 1 FMP52 Position 3 (Power Supply; Output) = A (TRC [21], [31]) A T6 ( 85 C) 50 C 60 C 60 C 60 C 85 C 53 C 85 C 40 C 40 C 40 C 50 C 37 C T5 (100 C) 50 C 75 C 75 C 75 C 100 C 68 C 100 C 40 C 40 C 40 C 50 C 37 C T4 (135 C) 50 C 80 C 81 C 80 C 135 C 69 C 135 C 40 C 40 C 40 C 50 C 37 C T3 (200 C) 50 C 80 C 81 C 80 C 200 C 53 C 200 C 40 C 40 C 40 C 50 C 37 C A T6 ( 85 C) 50 C 60 C 60 C 60 C 85 C 55 C 85 C 40 C 40 C 40 C 50 C 38 C T5 (100 C) 50 C 75 C 75 C 75 C 100 C 70 C 100 C 40 C 40 C 40 C 50 C 38 C T4 (135 C) 50 C 80 C 81 C 80 C 135 C 71 C 135 C 40 C 40 C 40 C 50 C 38 C T3 (200 C) 50 C 80 C 81 C 80 C 200 C 59 C 200 C 40 C 40 C 40 C 50 C 38 C Position 3 (Power Supply; Output) = B (TRC [02], [22]) B: 1 channel used T6 ( 85 C) 50 C 60 C 60 C 60 C 85 C 53 C 85 C 40 C 40 C 40 C 50 C 37 C T5 (100 C) 50 C 75 C 75 C 75 C 100 C 68 C 100 C 40 C 40 C 40 C 50 C 37 C T4 (135 C) 50 C 80 C 80 C 80 C 135 C 68 C 135 C 40 C 40 C 40 C 50 C 37 C T3 (200 C) 50 C 80 C 80 C 80 C 200 C 53 C 200 C 40 C 40 C 40 C 50 C 37 C B: 2 channels used T6 ( 85 C) 50 C 51 C 51 C 51 C 85 C 44 C 85 C 40 C 40 C 40 C 50 C 37 C T5 (100 C) 50 C 66 C 66 C 66 C 100 C 59 C 100 C 40 C 40 C 40 C 50 C 37 C T4 (135 C) 50 C 75 C 75 C 75 C 135 C 61 C 135 C 40 C 40 C 40 C 50 C 37 C T3 (200 C) 50 C 75 C 75 C 75 C 200 C 47 C 200 C 40 C 40 C 40 C 50 C 37 C 22 Endress+Hauser
23 XA00531F-D B: 1 channel used T6 ( 85 C) 50 C 60 C 60 C 60 C 85 C 55 C 85 C 40 C 40 C 40 C 50 C 38 C T5 (100 C) 50 C 75 C 75 C 75 C 100 C 70 C 100 C 40 C 40 C 40 C 50 C 38 C T4 (135 C) 50 C 80 C 80 C 80 C 135 C 70 C 135 C 40 C 40 C 40 C 50 C 38 C T3 (200 C) 50 C 80 C 80 C 80 C 200 C 58 C 200 C 40 C 40 C 40 C 50 C 38 C B: 2 channels used T6 ( 85 C) 50 C 51 C 51 C 51 C 85 C 45 C 85 C 40 C 40 C 40 C 50 C 38 C T5 (100 C) 50 C 66 C 66 C 66 C 100 C 60 C 100 C 40 C 40 C 40 C 50 C 38 C T4 (135 C) 50 C 75 C 75 C 75 C 135 C 64 C 135 C 40 C 40 C 40 C 50 C 38 C T3 (200 C) 50 C 75 C 75 C 75 C 200 C 52 C 200 C 40 C 40 C 40 C 50 C 38 C Position 3 (Power Supply; Output) = C (TRC [04]) C: 1 channel used T6 ( 85 C) 50 C 60 C 60 C 60 C 85 C 52 C 85 C 40 C 40 C 40 C 50 C 37 C T5 (100 C) 50 C 75 C 75 C 75 C 100 C 67 C 100 C 40 C 40 C 40 C 50 C 37 C T4 (135 C) 50 C 80 C 80 C 80 C 135 C 69 C 135 C 40 C 40 C 40 C 50 C 37 C T3 (200 C) 50 C 80 C 80 C 80 C 200 C 52 C 200 C 40 C 40 C 40 C 50 C 37 C C: 2 channels used T6 ( 85 C) 50 C 54 C 54 C 54 C 85 C 47 C 85 C 40 C 40 C 40 C 50 C 37 C T5 (100 C) 50 C 69 C 69 C 69 C 100 C 62 C 100 C 40 C 40 C 40 C 50 C 37 C T4 (135 C) 50 C 78 C 78 C 78 C 135 C 65 C 135 C 40 C 40 C 40 C 50 C 37 C T3 (200 C) 50 C 78 C 78 C 78 C 200 C 50 C 200 C 40 C 40 C 40 C 50 C 37 C C: 1 channel used T6 ( 85 C) 50 C 60 C 60 C 60 C 85 C 54 C 85 C 40 C 40 C 40 C 50 C 37 C T5 (100 C) 50 C 75 C 75 C 75 C 100 C 69 C 100 C 40 C 40 C 40 C 50 C 37 C T4 (135 C) 50 C 80 C 80 C 80 C 135 C 71 C 135 C 40 C 40 C 40 C 50 C 37 C T3 (200 C) 50 C 80 C 80 C 80 C 200 C 59 C 200 C 40 C 40 C 40 C 50 C 37 C C: 2 channels used T6 ( 85 C) 50 C 54 C 54 C 54 C 85 C 48 C 85 C 40 C 40 C 40 C 50 C 37 C T5 (100 C) 50 C 69 C 69 C 69 C 100 C 63 C 100 C 40 C 40 C 40 C 50 C 37 C T4 (135 C) 50 C 78 C 78 C 78 C 135 C 67 C 135 C 40 C 40 C 40 C 50 C 37 C T3 (200 C) 50 C 78 C 78 C 78 C 200 C 55 C 200 C 40 C 40 C 40 C 50 C 37 C Endress+Hauser 23
24 XA00531F-D Intrinsically Safe (IS) Probe: Class I, Zone 0 / Class I, Division 1 Electronics housing: Class I, Zone 1 / Class I, Division 1 FMP53 Position 3 (Power Supply; Output) = A (TRC [21], [31]) A T6 ( 85 C) 20 C 60 C 60 C 60 C 85 C 54 C 85 C 20 C 20 C 20 C - - T5 (100 C) 20 C 75 C 75 C 75 C 100 C 69 C 100 C 20 C 20 C 20 C - - T4 (135 C) 20 C 80 C 81 C 80 C 135 C 70 C 135 C 20 C 20 C 20 C - - T3 (200 C) 20 C 80 C 81 C 80 C 150 C 66 C 150 C 20 C 20 C 20 C - - Position 3 (Power Supply; Output) = B (TRC [02], [22]) B: 1 channel used T6 ( 85 C) 20 C 60 C 60 C 60 C 85 C 54 C 85 C 20 C 20 C 20 C - - T5 (100 C) 20 C 75 C 75 C 75 C 100 C 69 C 100 C 20 C 20 C 20 C - - T4 (135 C) 20 C 80 C 80 C 80 C 135 C 69 C 135 C 20 C 20 C 20 C - - T3 (200 C) 20 C 80 C 80 C 80 C 150 C 66 C 150 C 20 C 20 C 20 C - - B: 2 channels used T6 ( 85 C) 20 C 51 C 51 C 51 C 85 C 44 C 85 C 20 C 20 C 20 C - - T5 (100 C) 20 C 66 C 66 C 66 C 100 C 59 C 100 C 20 C 20 C 20 C - - T4 (135 C) 20 C 75 C 75 C 75 C 135 C 63 C 135 C 20 C 20 C 20 C - - T3 (200 C) 20 C 75 C 75 C 75 C 150 C 59 C 150 C 20 C 20 C 20 C - - Position 3 (Power Supply; Output) = C (TRC [04]) C: 1 channel used T6 ( 85 C) 20 C 60 C 60 C 60 C 85 C 54 C 85 C 20 C 20 C 20 C - - T5 (100 C) 20 C 75 C 75 C 75 C 100 C 69 C 100 C 20 C 20 C 20 C - - T4 (135 C) 20 C 80 C 80 C 80 C 135 C 70 C 135 C 20 C 20 C 20 C - - T3 (200 C) 20 C 80 C 80 C 80 C 150 C 67 C 150 C 20 C 20 C 20 C - - C: 2 channels used T6 ( 85 C) 20 C 54 C 54 C 54 C 85 C 48 C 85 C 20 C 20 C 20 C - - T5 (100 C) 20 C 69 C 69 C 69 C 100 C 63 C 100 C 20 C 20 C 20 C - - T4 (135 C) 20 C 78 C 78 C 78 C 135 C 66 C 135 C 20 C 20 C 20 C - - T3 (200 C) 20 C 78 C 78 C 78 C 150 C 63 C 150 C 20 C 20 C 20 C Endress+Hauser
25 XA00531F-D Intrinsically Safe (IS) Probe: Class I, Zone 0 / Class I, Division 1 Electronics housing: Class I, Zone 1 / Class I, Division 1 FMP54, Position 9, 10 (Seal) = D1 Position 3 (Power Supply; Output) = A (TRC [21], [31]) A T6 ( 85 C) 196 C 60 C 60 C 60 C 85 C 56 C 85 C 40 C 40 C 40 C 196 C 16 C T5 (100 C) 196 C 75 C 75 C 75 C 100 C 71 C 100 C 40 C 40 C 40 C 196 C 16 C T4 (135 C) 196 C 80 C 81 C 80 C 135 C 74 C 135 C 40 C 40 C 40 C 196 C 16 C T3 (200 C) 196 C 80 C 81 C 80 C 200 C 65 C 200 C 40 C 40 C 40 C 196 C 16 C T2 (300 C) 196 C 80 C 81 C 80 C 280 C 54 C 280 C 40 C 40 C 40 C 196 C 16 C A T6 ( 85 C) 196 C 60 C 60 C 60 C 85 C 57 C 85 C 40 C 40 C 40 C 196 C 23 C T5 (100 C) 196 C 75 C 75 C 75 C 100 C 72 C 100 C 40 C 40 C 40 C 196 C 23 C T4 (135 C) 196 C 80 C 81 C 80 C 135 C 75 C 135 C 40 C 40 C 40 C 196 C 23 C T3 (200 C) 196 C 80 C 81 C 80 C 200 C 69 C 200 C 40 C 40 C 40 C 196 C 23 C T2 (300 C) 196 C 80 C 81 C 80 C 280 C 61 C 280 C 40 C 40 C 40 C 196 C 23 C Endress+Hauser 25
26 XA00531F-D Position 3 (Power Supply; Output) = B (TRC [02], [22]) B: 1 channel used T6 ( 85 C) 196 C 60 C 60 C 60 C 85 C 56 C 85 C 40 C 40 C 40 C 196 C 16 C T5 (100 C) 196 C 75 C 75 C 75 C 100 C 71 C 100 C 40 C 40 C 40 C 196 C 16 C T4 (135 C) 196 C 80 C 80 C 80 C 135 C 73 C 135 C 40 C 40 C 40 C 196 C 16 C T3 (200 C) 196 C 80 C 80 C 80 C 200 C 64 C 200 C 40 C 40 C 40 C 196 C 16 C T2 (300 C) 196 C 80 C 80 C 80 C 280 C 53 C 280 C 40 C 40 C 40 C 196 C 16 C B: 2 channels used T6 ( 85 C) 196 C 51 C 51 C 51 C 85 C 47 C 85 C 40 C 40 C 40 C 196 C 16 C T5 (100 C) 196 C 66 C 66 C 66 C 100 C 62 C 100 C 40 C 40 C 40 C 196 C 16 C T4 (135 C) 196 C 75 C 75 C 75 C 135 C 67 C 135 C 40 C 40 C 40 C 196 C 16 C T3 (200 C) 196 C 75 C 75 C 75 C 200 C 58 C 200 C 40 C 40 C 40 C 196 C 16 C T2 (300 C) 196 C 75 C 75 C 75 C 280 C 48 C 280 C 40 C 40 C 40 C 196 C 16 C Power Supply; Output / Temperature class P 1 P 2 P 3 P 4 P 5 P 6 B: 1 channel used T6 ( 85 C) 196 C 60 C 60 C 60 C 85 C 57 C 85 C 40 C 40 C 40 C 196 C 23 C T5 (100 C) 196 C 75 C 75 C 75 C 100 C 72 C 100 C 40 C 40 C 40 C 196 C 23 C T4 (135 C) 196 C 80 C 80 C 80 C 135 C 75 C 135 C 40 C 40 C 40 C 196 C 23 C T3 (200 C) 196 C 80 C 80 C 80 C 200 C 68 C 200 C 40 C 40 C 40 C 196 C 23 C T2 (300 C) 196 C 80 C 80 C 80 C 280 C 60 C 280 C 40 C 40 C 40 C 196 C 23 C B: 2 channels used T6 ( 85 C) 196 C 51 C 51 C 51 C 85 C 48 C 85 C 40 C 40 C 40 C 196 C 23 C T5 (100 C) 196 C 66 C 66 C 66 C 100 C 63 C 100 C 40 C 40 C 40 C 196 C 23 C T4 (135 C) 196 C 75 C 75 C 75 C 135 C 69 C 135 C 40 C 40 C 40 C 196 C 23 C T3 (200 C) 196 C 75 C 75 C 75 C 200 C 63 C 200 C 40 C 40 C 40 C 196 C 23 C T2 (300 C) 196 C 75 C 75 C 75 C 280 C 55 C 280 C 40 C 40 C 40 C 196 C 23 C 26 Endress+Hauser
27 XA00531F-D Position 3 (Power Supply; Output) = C (TRC [04]) C: 1 channel used T6 ( 85 C) 196 C 60 C 60 C 60 C 85 C 56 C 85 C 40 C 40 C 40 C 196 C 16 C T5 (100 C) 196 C 75 C 75 C 75 C 100 C 71 C 100 C 40 C 40 C 40 C 196 C 16 C T4 (135 C) 196 C 80 C 80 C 80 C 135 C 74 C 135 C 40 C 40 C 40 C 196 C 16 C T3 (200 C) 196 C 80 C 80 C 80 C 200 C 65 C 200 C 40 C 40 C 40 C 196 C 16 C T2 (300 C) 196 C 80 C 80 C 80 C 280 C 55 C 280 C 40 C 40 C 40 C 196 C 16 C C: 2 channels used T6 ( 85 C) 196 C 54 C 54 C 54 C 85 C 50 C 85 C 40 C 40 C 40 C 196 C 16 C T5 (100 C) 196 C 69 C 69 C 69 C 100 C 65 C 100 C 40 C 40 C 40 C 196 C 16 C T4 (135 C) 196 C 78 C 78 C 78 C 135 C 70 C 135 C 40 C 40 C 40 C 196 C 16 C T3 (200 C) 196 C 78 C 78 C 78 C 200 C 61 C 200 C 40 C 40 C 40 C 196 C 16 C T2 (300 C) 196 C 78 C 78 C 78 C 280 C 51 C 280 C 40 C 40 C 40 C 196 C 16 C C: 1 channel used T6 ( 85 C) 196 C 60 C 60 C 60 C 85 C 57 C 85 C 40 C 40 C 40 C 196 C 23 C T5 (100 C) 196 C 75 C 75 C 75 C 100 C 72 C 100 C 40 C 40 C 40 C 196 C 23 C T4 (135 C) 196 C 80 C 80 C 80 C 135 C 76 C 135 C 40 C 40 C 40 C 196 C 23 C T3 (200 C) 196 C 80 C 80 C 80 C 200 C 69 C 200 C 40 C 40 C 40 C 196 C 23 C T2 (300 C) 196 C 80 C 80 C 80 C 280 C 61 C 280 C 40 C 40 C 40 C 196 C 23 C C: 2 channels used T6 ( 85 C) 196 C 54 C 54 C 54 C 85 C 51 C 85 C 40 C 40 C 40 C 196 C 23 C T5 (100 C) 196 C 69 C 69 C 69 C 100 C 66 C 100 C 40 C 40 C 40 C 196 C 23 C T4 (135 C) 196 C 78 C 78 C 78 C 135 C 72 C 135 C 40 C 40 C 40 C 196 C 23 C T3 (200 C) 196 C 78 C 78 C 78 C 200 C 65 C 200 C 40 C 40 C 40 C 196 C 23 C T2 (300 C) 196 C 78 C 78 C 78 C 280 C 57 C 280 C 40 C 40 C 40 C 196 C 23 C Endress+Hauser 27
28 XA00531F-D Intrinsically Safe (IS) Probe: Class I, Zone 0 / Class I, Division 1 Electronics housing: Class I, Zone 1 / Class I, Division 1 FMP54, Position 9, 10 (Seal) = D2 Position 3 (Power Supply; Output) = A (TRC [21], [31]) A T6 ( 85 C) 196 C 60 C 60 C 60 C 85 C 58 C 85 C 40 C 40 C 40 C 196 C 27 C T5 (100 C) 196 C 75 C 75 C 75 C 100 C 73 C 100 C 40 C 40 C 40 C 196 C 27 C T4 (135 C) 196 C 80 C 81 C 80 C 135 C 77 C 135 C 40 C 40 C 40 C 196 C 27 C T3 (200 C) 196 C 80 C 81 C 80 C 200 C 72 C 200 C 40 C 40 C 40 C 196 C 27 C T2 (300 C) 196 C 80 C 81 C 80 C 300 C 64 C 300 C 40 C 40 C 40 C 196 C 27 C T1 (450 C) * C 80 C 81 C 80 C 450 C 53 C 450 C 40 C 40 C 40 C 196 C 27 C A T6 ( 85 C) 196 C 60 C 60 C 60 C 85 C 58 C 85 C 40 C 40 C 40 C 196 C 28 C T5 (100 C) 196 C 75 C 75 C 75 C 100 C 73 C 100 C 40 C 40 C 40 C 196 C 28 C T4 (135 C) 196 C 80 C 81 C 80 C 135 C 77 C 135 C 40 C 40 C 40 C 196 C 28 C T3 (200 C) 196 C 80 C 81 C 80 C 200 C 72 C 200 C 40 C 40 C 40 C 196 C 28 C T2 (300 C) 196 C 80 C 81 C 80 C 300 C 65 C 300 C 40 C 40 C 40 C 196 C 28 C T1 (450 C) * C 80 C 81 C 80 C 450 C 55 C 450 C 40 C 40 C 40 C 196 C 28 C 28 Endress+Hauser
29 XA00531F-D Position 3 (Power Supply; Output) = B (TRC [02], [22]) B: 1 channel used T6 ( 85 C) 196 C 60 C 60 C 60 C 85 C 58 C 85 C 40 C 40 C 40 C 196 C 27 C T5 (100 C) 196 C 75 C 75 C 75 C 100 C 73 C 100 C 40 C 40 C 40 C 196 C 27 C T4 (135 C) 196 C 80 C 80 C 80 C 135 C 76 C 135 C 40 C 40 C 40 C 196 C 27 C T3 (200 C) 196 C 80 C 80 C 80 C 200 C 71 C 200 C 40 C 40 C 40 C 196 C 27 C T2 (300 C) 196 C 80 C 80 C 80 C 300 C 63 C 300 C 40 C 40 C 40 C 196 C 27 C T1 (450 C) * C 80 C 80 C 80 C 450 C 52 C 450 C 40 C 40 C 40 C 196 C 27 C B: 2 channels used T6 ( 85 C) 196 C 51 C 51 C 51 C 85 C 49 C 85 C 40 C 40 C 40 C 196 C 27 C T5 (100 C) 196 C 66 C 66 C 66 C 100 C 64 C 100 C 40 C 40 C 40 C 196 C 27 C T4 (135 C) 196 C 75 C 75 C 75 C 135 C 70 C 135 C 40 C 40 C 40 C 196 C 27 C T3 (200 C) 196 C 75 C 75 C 75 C 200 C 66 C 200 C 40 C 40 C 40 C 196 C 27 C T2 (300 C) 196 C 75 C 75 C 75 C 300 C 58 C 300 C 40 C 40 C 40 C 196 C 27 C T1 (450 C) * C 75 C 75 C 75 C 450 C 47 C 450 C 40 C 40 C 40 C 196 C 27 C B: 1 channel used T6 ( 85 C) 196 C 60 C 60 C 60 C 85 C 58 C 85 C 40 C 40 C 40 C 196 C 28 C T5 (100 C) 196 C 75 C 75 C 75 C 100 C 73 C 100 C 40 C 40 C 40 C 196 C 28 C T4 (135 C) 196 C 80 C 80 C 80 C 135 C 76 C 135 C 40 C 40 C 40 C 196 C 28 C T3 (200 C) 196 C 80 C 80 C 80 C 200 C 72 C 200 C 40 C 40 C 40 C 196 C 28 C T2 (300 C) 196 C 80 C 80 C 80 C 300 C 65 C 300 C 40 C 40 C 40 C 196 C 28 C T1 (450 C) * C 80 C 80 C 80 C 450 C 54 C 450 C 40 C 40 C 40 C 196 C 28 C B: 2 channels used T6 ( 85 C) 196 C 51 C 51 C 51 C 85 C 49 C 85 C 40 C 40 C 40 C 196 C 28 C T5 (100 C) 196 C 66 C 66 C 66 C 100 C 64 C 100 C 40 C 40 C 40 C 196 C 28 C T4 (135 C) 196 C 75 C 75 C 75 C 135 C 71 C 135 C 40 C 40 C 40 C 196 C 28 C T3 (200 C) 196 C 75 C 75 C 75 C 200 C 66 C 200 C 40 C 40 C 40 C 196 C 28 C T2 (300 C) 196 C 75 C 75 C 75 C 300 C 59 C 300 C 40 C 40 C 40 C 196 C 28 C T1 (450 C) * C 75 C 75 C 75 C 450 C 49 C 450 C 40 C 40 C 40 C 196 C 28 C Endress+Hauser 29
30 XA00531F-D Position 3 (Power Supply; Output) = C (TRC [04]) C: 1 channel used T6 ( 85 C) 196 C 60 C 60 C 60 C 85 C 57 C 85 C 40 C 40 C 40 C 196 C 26 C T5 (100 C) 196 C 75 C 75 C 75 C 100 C 72 C 100 C 40 C 40 C 40 C 196 C 26 C T4 (135 C) 196 C 80 C 80 C 80 C 135 C 77 C 135 C 40 C 40 C 40 C 196 C 26 C T3 (200 C) 196 C 80 C 80 C 80 C 200 C 72 C 200 C 40 C 40 C 40 C 196 C 26 C T2 (300 C) 196 C 80 C 80 C 80 C 300 C 65 C 300 C 40 C 40 C 40 C 196 C 26 C T1 (450 C) * C 80 C 80 C 80 C 450 C 53 C 450 C 40 C 40 C 40 C 196 C 26 C C: 2 channels used T6 ( 85 C) 196 C 54 C 54 C 54 C 85 C 52 C 85 C 40 C 40 C 40 C 196 C 26 C T5 (100 C) 196 C 69 C 69 C 69 C 100 C 67 C 100 C 40 C 40 C 40 C 196 C 26 C T4 (135 C) 196 C 78 C 78 C 78 C 135 C 73 C 135 C 40 C 40 C 40 C 196 C 26 C T3 (200 C) 196 C 78 C 78 C 78 C 200 C 68 C 200 C 40 C 40 C 40 C 196 C 26 C T2 (300 C) 196 C 78 C 78 C 78 C 300 C 61 C 300 C 40 C 40 C 40 C 196 C 26 C T1 (450 C) * C 78 C 78 C 78 C 450 C 49 C 450 C 40 C 40 C 40 C 196 C 26 C C: 1 channel used T6 ( 85 C) 196 C 60 C 60 C 60 C 85 C 58 C 85 C 40 C 40 C 40 C 196 C 27 C T5 (100 C) 196 C 75 C 75 C 75 C 100 C 73 C 100 C 40 C 40 C 40 C 196 C 27 C T4 (135 C) 196 C 80 C 80 C 80 C 135 C 77 C 135 C 40 C 40 C 40 C 196 C 27 C T3 (200 C) 196 C 80 C 80 C 80 C 200 C 73 C 200 C 40 C 40 C 40 C 196 C 27 C T2 (300 C) 196 C 80 C 80 C 80 C 300 C 66 C 300 C 40 C 40 C 40 C 196 C 27 C T1 (450 C) * C 80 C 80 C 80 C 450 C 55 C 450 C 40 C 40 C 40 C 196 C 27 C C: 2 channels used T6 ( 85 C) 196 C 54 C 54 C 54 C 85 C 52 C 85 C 40 C 40 C 40 C 196 C 27 C T5 (100 C) 196 C 69 C 69 C 69 C 100 C 67 C 100 C 40 C 40 C 40 C 196 C 27 C T4 (135 C) 196 C 78 C 78 C 78 C 135 C 74 C 135 C 40 C 40 C 40 C 196 C 27 C T3 (200 C) 196 C 78 C 78 C 78 C 200 C 69 C 200 C 40 C 40 C 40 C 196 C 27 C T2 (300 C) 196 C 78 C 78 C 78 C 300 C 62 C 300 C 40 C 40 C 40 C 196 C 27 C T1 (450 C) * C 78 C 78 C 78 C 450 C 51 C 450 C 40 C 40 C 40 C 196 C 27 C 30 Endress+Hauser
31 XA00531F-D Intrinsically Safe (IS) Probe: Class I, Zone 0 / Class I, Division 1 Electronics housing: Class I, Zone 1 / Class I, Division 1 FMP55 Position 3 (Power Supply; Output) = A (TRC [21], [31]) A T6 ( 85 C) 50 C 60 C 60 C 60 C 85 C 54 C 85 C 40 C 40 C 40 C 50 C 37 C T5 (100 C) 50 C 75 C 75 C 75 C 100 C 69 C 100 C 40 C 40 C 40 C 50 C 37 C T4 (135 C) 50 C 80 C 81 C 80 C 135 C 69 C 135 C 40 C 40 C 40 C 50 C 37 C T3 (200 C) 50 C 80 C 81 C 80 C 200 C 55 C 200 C 40 C 40 C 40 C 50 C 37 C A T6 ( 85 C) 50 C 60 C 60 C 60 C 85 C 55 C 85 C 40 C 40 C 40 C 50 C 38 C T5 (100 C) 50 C 75 C 75 C 75 C 100 C 70 C 100 C 40 C 40 C 40 C 50 C 38 C T4 (135 C) 50 C 80 C 81 C 80 C 135 C 70 C 135 C 40 C 40 C 40 C 50 C 38 C T3 (200 C) 50 C 80 C 81 C 80 C 200 C 57 C 200 C 40 C 40 C 40 C 50 C 38 C Position 3 (Power Supply; Output) = B (TRC [02], [22]) B: 1 channel used T6 ( 85 C) 50 C 60 C 60 C 60 C 85 C 54 C 85 C 40 C 40 C 40 C 50 C 37 C T5 (100 C) 50 C 75 C 75 C 75 C 100 C 69 C 100 C 40 C 40 C 40 C 50 C 37 C T4 (135 C) 50 C 80 C 80 C 80 C 135 C 68 C 135 C 40 C 40 C 40 C 50 C 37 C T3 (200 C) 50 C 80 C 80 C 80 C 200 C 54 C 200 C 40 C 40 C 40 C 50 C 37 C B: 2 channels used T6 ( 85 C) 50 C 51 C 51 C 51 C 85 C 44 C 85 C 40 C 40 C 40 C 50 C 37 C T5 (100 C) 50 C 66 C 66 C 66 C 100 C 59 C 100 C 40 C 40 C 40 C 50 C 37 C T4 (135 C) 50 C 75 C 75 C 75 C 135 C 62 C 135 C 40 C 40 C 40 C 50 C 37 C T3 (200 C) 50 C 75 C 75 C 75 C 200 C 48 C 200 C 40 C 40 C 40 C 50 C 37 C Endress+Hauser 31
32 XA00531F-D B: 1 channel used T6 ( 85 C) 50 C 60 C 60 C 60 C 85 C 55 C 85 C 40 C 40 C 40 C 50 C 38 C T5 (100 C) 50 C 75 C 75 C 75 C 100 C 70 C 100 C 40 C 40 C 40 C 50 C 38 C T4 (135 C) 50 C 80 C 80 C 80 C 135 C 69 C 135 C 40 C 40 C 40 C 50 C 38 C T3 (200 C) 50 C 80 C 80 C 80 C 200 C 56 C 200 C 40 C 40 C 40 C 50 C 38 C B: 2 channels used T6 ( 85 C) 50 C 51 C 51 C 51 C 85 C 45 C 85 C 40 C 40 C 40 C 50 C 38 C T5 (100 C) 50 C 66 C 66 C 66 C 100 C 60 C 100 C 40 C 40 C 40 C 50 C 38 C T4 (135 C) 50 C 75 C 75 C 75 C 135 C 63 C 135 C 40 C 40 C 40 C 50 C 38 C T3 (200 C) 50 C 75 C 75 C 75 C 200 C 50 C 200 C 40 C 40 C 40 C 50 C 38 C Position 3 (Power Supply; Output) = C (TRC [04]) C: 1 channel used T6 ( 85 C) 50 C 60 C 60 C 60 C 85 C 52 C 85 C 40 C 40 C 40 C 50 C 37 C T5 (100 C) 50 C 75 C 75 C 75 C 100 C 67 C 100 C 40 C 40 C 40 C 50 C 37 C T4 (135 C) 50 C 80 C 80 C 80 C 135 C 69 C 135 C 40 C 40 C 40 C 50 C 37 C T3 (200 C) 50 C 80 C 80 C 80 C 200 C 52 C 200 C 40 C 40 C 40 C 50 C 37 C C: 2 channels used T6 ( 85 C) 50 C 54 C 54 C 54 C 85 C 47 C 85 C 40 C 40 C 40 C 50 C 37 C T5 (100 C) 50 C 69 C 69 C 69 C 100 C 62 C 100 C 40 C 40 C 40 C 50 C 37 C T4 (135 C) 50 C 78 C 78 C 78 C 135 C 65 C 135 C 40 C 40 C 40 C 50 C 37 C T3 (200 C) 50 C 78 C 78 C 78 C 200 C 50 C 200 C 40 C 40 C 40 C 50 C 37 C C: 1 channel used T6 ( 85 C) 50 C 60 C 60 C 60 C 85 C 54 C 85 C 40 C 40 C 40 C 50 C 37 C T5 (100 C) 50 C 75 C 75 C 75 C 100 C 69 C 100 C 40 C 40 C 40 C 50 C 37 C T4 (135 C) 50 C 80 C 80 C 80 C 135 C 71 C 135 C 40 C 40 C 40 C 50 C 37 C T3 (200 C) 50 C 80 C 80 C 80 C 200 C 58 C 200 C 40 C 40 C 40 C 50 C 37 C C: 2 channels used T6 ( 85 C) 50 C 54 C 54 C 54 C 85 C 48 C 85 C 40 C 40 C 40 C 50 C 37 C T5 (100 C) 50 C 69 C 69 C 69 C 100 C 63 C 100 C 40 C 40 C 40 C 50 C 37 C T4 (135 C) 50 C 78 C 78 C 78 C 135 C 66 C 135 C 40 C 40 C 40 C 50 C 37 C T3 (200 C) 50 C 78 C 78 C 78 C 200 C 54 C 200 C 40 C 40 C 40 C 50 C 37 C 32 Endress+Hauser
33 XA00531F-D Intrinsically Safe (IS) Probe: Class I, Zone 0 / Class I, Division 1 Electronics housing: Class I, Zone 1 / Class I, Division 1 FMP56 Position 3 (Power Supply; Output) = A (TRC [21], [31]) A T6 ( 85 C) 40 C 60 C 60 C 60 C 85 C 52 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 75 C 75 C 75 C 100 C 67 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 80 C 81 C 80 C 120 C 72 C 120 C 40 C 40 C 40 C - - A T6 ( 85 C) 40 C 60 C 60 C 60 C 85 C 54 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 75 C 75 C 75 C 100 C 69 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 80 C 81 C 80 C 120 C 73 C 120 C 40 C 40 C 40 C - - Position 3 (Power Supply; Output) = B (TRC [02], [22]) B: 1 channel used T6 ( 85 C) 40 C 60 C 60 C 60 C 85 C 52 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 75 C 75 C 75 C 100 C 67 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 80 C 80 C 80 C 120 C 71 C 120 C 40 C 40 C 40 C - - B: 2 channels used T6 ( 85 C) 40 C 51 C 51 C 51 C 85 C 43 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 66 C 66 C 66 C 100 C 58 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 75 C 75 C 75 C 120 C 64 C 120 C 40 C 40 C 40 C - - B: 1 channel used T6 ( 85 C) 40 C 60 C 60 C 60 C 85 C 54 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 75 C 75 C 75 C 100 C 69 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 80 C 80 C 80 C 120 C 72 C 120 C 40 C 40 C 40 C - - B: 2 channels used T6 ( 85 C) 40 C 51 C 51 C 51 C 85 C 44 C 85 C 40 C 40 C 40 C - - T5 (100 C) 40 C 66 C 66 C 66 C 100 C 59 C 100 C 40 C 40 C 40 C - - T4 (135 C) 40 C 75 C 75 C 75 C 120 C 66 C 120 C 40 C 40 C 40 C - - Endress+Hauser 33
Safety Instructions Micropilot FMR50/51/52/53/54/56/57
/00/EN/01.14 71252403 Products Solutions Services Safety Instructions FMR50/51/52/53/54/56/57 4-20 ma HART, 2-wire, 4...20 ma Ex ic IIC T6 Gc Segurança TÜV INMETRO OCP 0004 Document: Safety instructions
More informationSafety Instructions Micropilot FMR56/57
XA01299F-A/00/EN/01.14 71252565 Products Solutions Services Safety Instructions FMR56/57 PROFIBUS PA, FOUNDATION Fieldbus Ex ta IIIC T 500 xx C Da Segurança TÜV INMETRO OCP 0004 Document: XA01299F-A Safety
More informationSafety Instructions Cerabar S PMP71, PMP75
/00/EN/01.14 71249311 Products Solutions Services Safety Instructions PMP71, PMP75 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex d IIC T* Gb TÜV 13.0902X Segurança TÜV INMETRO OCP 0004 Document: Safety
More informationSafety Instructions Cerabar M PMC51, PMP51, PMP55
XA00470P-B/00/EN/14.13 71224652 Products Solutions Services Safety Instructions PMC51, PMP51, PMP55 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex ia IIC T6...T4 Ga/Gb Ex ia IIC T6...T3 Ga/Gb IECEx
More informationCerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus
Safety Instructions PMC71, PMP71, PMP75 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex ia IIC T6 Ga/Gb IECEx KEM06.0011 0 XA00696P-D Safety instructions for electrical apparatus for explosion-hazardous
More informationSMARTLINE RM76 Supplementary instructions
SMARTLINE RM76 Supplementary instructions 2-wire / Guided Radar (TDR) Level Meter Supplementary Instructions for ATEX applications CONTENTS SMARTLINE RM76 1 General safety information 5 1.1 Scope of the
More information4 â Active barrier RN221N with optional HART diagnosis. Technical Information
Technical Information Active barrier with optional HART diagnosis Active barrier with power supply for safe separation of 4 to 20 ma current circuits Application Galvanic isolation of 4 to 20 ma current
More informationSafety Instructions Proservo NMS80, NMS81, NMS83
/08/EN/01.16 71325066 Products Solutions Services Safety Instructions Proservo NMS80, NMS81, NMS83 ATEX: II 1/2G Ex d[ia] IIC T6...T1 Ga/Gb IECEx: Ex db[ia Ga] IIC T6...T1 Ga/Gb Safety instructions for
More informationDR7100 SERIES Supplementary instructions
DR700 SERIES Supplementary instructions Guided Radar (TDR) Level Instrument for 2-wire control systems Supplementary Instructions for ATEX applications AMETEK Drexelbrook - EDO -0-2, DR700-LM ATEX, Issue
More informationInstallation & Operation Manual
Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationOperating Instructions
Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on
More informationLMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.
LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:
More information5 Fieldbus Technology
5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically
More informationLevel-Lance Model 5400A
Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing
More informationIntrinsic Safety Control Drawing
s Intrinsic Safety Control Drawing system in total PLC PC Not hazardous area PROFIBUS DP Associated Apparatus Class I, DIV 2, GP A...D Class I, ZN 1, IIC T4 PROFIBUS-DP Ex i Terminating resistor Class
More informationTFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5
EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on
More informationLevel instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration
Level instruments Overview Configuration is a versatile inverse frequency shift capacitance level slurries, foam and interfaces. The digital version (with PROFIBUS PA) includes a display and provides additional
More informationCombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.
EN/2017-04-03 Design and specifications subject to change without notice English page 1 8 Field of application CombiTemp TFRx is a temperature sensor, based on RTD technology, which is designed and produced
More informationProsonic T FMU30. Technical Information
Technical Information Prosonic T FMU30 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids, pastes and coarse bulk materials Application Continuous, non-contact
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99
More informationSeries 3730 Electropneumatic Positioner Type
Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm
More informationSeparating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information
Separating and protective instruments Separating and protective instruments VEGATRENN 149AEx Separator type KFDO Barrier type 9001 Product Information Content Content 1 Product description..........................................................................
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity
More informationINSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069
D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according
More informationDMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure
More informationFieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)
Data Sheet FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Intrinsically safe power supply of up to 31 stations on the bus cascadable multi barrier Intrinsically safe connection of up to 4 field
More informationLevel instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31
Level instruments Overview The unique modular design of the provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific
More informationInductive sensor with analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection
More informationCapacitance level switches LS 210 LS 220
KROHNE 03/2001 7.02374.31.00 GR/PRINTO Capacitance level switches Compact switches for liquids, solids, slurry, foam and interface; outstanding performance for a low price Easy to install, no moving parts,
More informationTechnical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm
Model Number Features 5 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications Switching element function
More informationOperating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015
Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationMagnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.
More informationTechnical Information Promonitor NRF560
TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo
More informationMANUAL Surge Protectors
PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery
More informationSafety instructions. IECEx TUN Ex ia IIC T6 Gb
Safety instructions ÜSB62-36G.C_* and ÜSB62-30W.C_* IECEx TUN 07.0002 Ex [ia Ga] IIC T6 Gb Ex ia IIC T6 Gb 0044 39878 Content 1 Area of applicability 3 2 General 3 3 Electrical data 3 3.1 Application conditions
More informationTechnical Data. General specifications. Output type Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone 2 and zone 22 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationSeries 3730 Type Electropneumatic Positioner
Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner
More informationInductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi
ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationTechnical Information RIA16
TI00144R/09/EN/02.13 71217088 Products Solutions Services Technical Information Field indicator Loop-powered field indicator for looping into the 4 to 20 ma current circuit Application Oil & gas Petrochemical
More informationAssembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.
Guided Level Radar Features Measurement independent of density, temperature, and dust Measurement also possible with foam on the surface Simple, menu-guided on-site operation with four-line plain text
More informationMINI MCR-SL-PT100-UI(-SP)(-NC)
Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationInductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting
More informationINSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F
PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4
More informationMicro Motion, Inc. Page 1 of 6
EB-20025742 Revision: AA Number of Pages: 6 Comments: Originator: HVH 10/01/13 Approved: RCS 11/26/13 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 11/26/13 Micro Motion, Inc. Page
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationLevel limit switch Series RF 3000 Selection list. Overview 2
Table of content Overview 2 Page Applications 4 ------------------------------------------------------------------------------------------------------------- RF 3100 6 Standard version -------------------------------------------------------------------------------------------------------------
More informationOperating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505
Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating
More informationLevelflex FMP53. Brief Operating Instructions. Guided Level-Radar
Brief Operating Instructions Guided Level-Radar These Instructions are Brief Operating Instructions; they do not replace the Operating Instructions included in the scope of supply. For detailed information,
More informationDigital Proximity System Installation Manual
Digital Proximity System Installation Manual 1180 The DPS (Digital Proximity System) family consists of two devices, the MX2033 and MX2034. The MX2033 is a conventional 3-wire driver while the MX2034 is
More informationFisher i2p-100 Electro-Pneumatic Transducer
i2p-100 Transducer Product Bulletin Fisher i2p-100 Electro-Pneumatic Transducer The Fisher i2p-100 electro-pneumatic transducer, uses a converter module that converts a milliampere input to a proportional
More informationApplication The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.
DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential
More informationGuided Wave Radar Level and Interface Transmitter
Quick Installation Guide Rosemount 3300 Series Guided Wave Radar Level and Interface Transmitter Start Step 1: Mount the Transmitter Head/Probe Step 2: Set Jumpers and Switches Step 3: Connect the Wiring
More informationSignal processor MS96 for flow sensors MS96-11EX0-R/230VAC
MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment
More informationZener Barriers Bulletin 937Z
Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution
More informationGeneral Specifications
General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process
More informationInductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position
More informationDigital Positioner 8049
Compact digital positioner for pneumatic control valves. Positioner can be integrated into valve actuator (no external moving parts for stroke feedback) Wide range of strokes - 8 mm No steady-state air
More informationPI-EX-ME-2NAM/COC-24VDC
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC
More informationYT-870 / 875 Series. Rotork YTC Limited VERSION 1.06
PRODUCT MANUAL Rotork YTC Limited VERSION 1.06 Contents 1 Introduction... 3 1.1 General Information for the users... 3 1.2 Manufacturer Warranty... 3 1.3 Explosion Proof Warning... 4 2 Product Description...
More informationInterface and Supply module. IPC 3x0i / PSC 3x0i
Interface and Supply module IPC 3x0i / PSC 3x0i Installation Guide Version 10 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.: +49 2241 9199801 53925 Kall Fax.: +49 2241 9199871 Germany www.ibs-batchcontrol.com
More informationFlow Measurement SITRANS F M
low sensor MAG P Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)
More informationM E M O R A N D U M I.S.
Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M
More informationGeneral Specifications
General Specifications EJA-E Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by
More information3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface
9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based
More informationRefer to attachment for more details. Andreas Meyer
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationBA304D Intrinsically safe loop-powered 3½ digit field mounting indicator issue 12
BA304D Intrinsically safe loop-powered 3½ digit field mounting indicator issue 12 Issue: 12 25 th September 2008 2 CONTENTS 1. Description 2. Operation 3. Intrinsic Safety Certification 3.1 ATEX certificate
More informationLMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO
Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mho up to 0... 00 mho Output signals wire:... 0 ma wire: 0... 0 V others
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof
More informationTechnical Information RIA15
T004K/09/EN/04.4 759844 Products Solutions Services Technical nformation RA5 Loop-powered 4 to 0 ma with optional HART communication Compact with very low voltage drop for universal use to display 4 to
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationD1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S
D109S INSTRUCTION MANUAL SIL Relay Output Module with Line and diagnostics DINRail Model D109S D109 SIL Relay Output Module with Line and diagnostics ISM0096 SIL Applications For Safety Related System
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationAssembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail
Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL
More informationSafety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.
Safety Barriers Description Safety barriers limit the energy fed to an intrinsically safe circuit so that neither sparks nor thermal effects (hot surfaces) can cause an explosion. CEAG safety barriers
More informationGeneral Specifications
General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process
More informationMagnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationFunctional safety manual Liquiphant M/S with FEL58 and Nivotester FTL325N
T T SD00170F/00/EN/13.13 71238754 Products Solutions Services Functional safety manual Liquiphant M/S with FEL58 and Nivotester FTL325N [Ex ia] [Ex ia] FTL325N FTL325N CH2 CH3 CH2 CH3 Level Limit Measuring
More informationInductive sensor BI1.5-EG08-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationPHOENIX CONTACT - 12/2007
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel
More informationSpare Parts for RM71 SmartLine Guided Radar Level Meter
Spare Parts f RM71 SmartLine Guided Radar Level Meter XM71 All but 2mm F 2mm probe style see MSG 36-RM-16-06 (XM72) 36-RM-16U-05 Page 1 of 8 Model Selection Guide Supply the iginal instrument model code
More informationPI-EX-ME-2NAM/COC-120VAC
PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description
More informationPROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001
PROCESS AUTOMATION MANUAL Z-System Zener Barriers ISO9001 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and
More informationDiffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTR 55 Ex Diffuse reflection light scanner with background suppression Dimensioned drawing en 01-2011/05 50113748 1 khz 5 400mm 200mm with black-white error < 10% 10-30
More informationData Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication
Data Sheet T 8493 EN Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,
More information4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12
0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationInstallation & Operation Manual
Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas
More informationSafety Instructions Omnigrad TRxx, TCxx, TxCxxx
XA01459T/09/EN/01.16 71340269 Products Solutions Services Safety Instructions Omnigrad TRxx, TCxx, TxCxxx RTD/TC modular thermometers 0ExiaIICT6...T1 X Document: XA01459T Safety instructions for electrical
More informationLMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.
LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mh O up to 0... 50 mh O Output signals -wire: 4... 0 ma -wire: 0...
More informationFlow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI
Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic
More information97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >
More informationPROFIBUS-PA Positioner Type 3785
PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,
More informationExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)
Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC
More informationSafety instructions Overvoltage protection B81-35
Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application
More informationSeries 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication
Series 3730 Electropneumatic Positioner Type 3730-4 with PROFIBUS-PA communication Application Positioner for attachment to pneumatic control valves Travels 3.6 to 200 mm Opening angle 24 to 100 Smart,
More information