Technical features. N/en
|
|
- Thomasine Summers
- 6 years ago
- Views:
Transcription
1 /, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface For single and double operated actuators Exhaust air recirculation at way function Monostable valves for safety systems up to SIL (IEC 508) Crossover-free switching, switch-over function guaranteed Add-on manual override Suited for outdoor use under critical environment conditions (see solenoid list) The solenoid valves are applicable in the protection classes Ex emb, Ex dmb, Ex mb, Ex ia for zones & (gas), & (dust), ATEX cat. II GD International approvals: IEC Ex, FM, CSA others on request. DIN EN 508 IEC 508 bis SIL Approval depends on magnetic system, see page 5 and! Certificated valves and temperature ranges see valve table on page and Technical features Medium: Filtered, non-lubricated and dried compressed air, instrument air, nitrogen and other nonflammable neutral, dry fluids Operation: Indirect solenoid operated spool valves Mounting position: Optional, impuls valves preferably horizontally Orifice: DN mm, DN 8 mm Port size:: G /, / NPT, G /, / NPT, NAMUR-Flange Operating pressure:, bar with internal air supply bar with external air supply, control pressure, bar (by G/, / NPT or low power pilot system only) Fluid/Ambient temperature: Valve: C (NBR) C (HNBR) Depending on solenoid system Air supply must be dry enough to avoid ice formation at temperatures below C. installed in the open protect all connections against the penetration of moisture! Materials: Body: aluminium.05 with surface treatment for rough environmantal conditions (condensate test with alternating temperatures in sulphuric environment, salt spray test with different sodium chloride solutions, tested in ammonia environment), brass.00 (Ms 58) or stainless steel.0 ( L) Seals: NBR (special perbunan) or HNBR / N/en
2 Valves with seals NBR C *) Housing: aluminium anodized, (5), Actuation Operating pressure Flow *) Test certification IEC 508 *) Model *) G / Flange Solenoid/spring, x 0, / NPT Flange Solenoid/spring, x 0,5 055 G / Flange Solenoid/spring, , / NPT Flange Solenoid/spring, ,80 05 G / Flange Solenoid/solenoid, ,5 505 / NPT Flange Solenoid/solenoid, , G / Flange Solenoid/solenoid (APB), , 505 / NPT Flange Solenoid/solenoid (APB), , 55 Housing: brass, (5), Actuation Operating pressure Flow *) Test certification IEC 508 *) Model *) G / Flange Solenoid/spring, x, / NPT Flange Solenoid/spring, x,00 05 G / Flange Solenoid/solenoid, ,0 05 / NPT Flange Solenoid/solenoid, ,0 5 5 G / Flange Solenoid/solenoid (APB), ,50 05 / NPT Flange Solenoid/solenoid (APB), ,50 5 Housing: stainless steel, (5), Actuation Operating pressure Flow *) Test certification IEC 508 *) Model *) G / Flange Solenoid/spring, x, / NPT Flange Solenoid/spring, x,00 05 G / Flange Solenoid/solenoid, ,0 05 / NPT Flange Solenoid/solenoid, ,0 5 G / Flange Solenoid/solenoid (APB), ,50 05 / NPT Flange Solenoid/solenoid (APB), , *) When ordering please indicate solenoid, voltage and current Models (frequency) *) Since May 008, Date code A8 *) For operation in plants according to IEC 5/ C see test certificate (on request) *) Connecting pipe/fitting: In order to ensure and a pressure collapse avoid the flow, the supply air cross section should with ¼: 8 mm; with ½: 0 mm its. With smaller cross section the inlet should more largely, however at least equally large line at the port its. APB = All Blocked / or 5/ way function (Conversion instructions see page ) N/en /
3 Valves with seals HNBR C *) Housing: aluminium anodized, (5), Actuation Operating pressure Flow *) Test certification IEC 508 *) Model *) G / Flange Solenoid/spring, x 0,5 005 / NPT Flange Solenoid/spring, x 0,5 05 G / Flange Solenoid/spring, x 0,80 05 / NPT Flange Solenoid/spring, x 0,80 0 G / Flange Solenoid/solenoid, ,5 05 / NPT Flange Solenoid/solenoid, ,5 5 5 G / Flange Solenoid/solenoid (APB), , 05 / NPT Flange Solenoid/solenoid (APB), , 5 Housing: aluminium anodized, Inlet filter and exhaust guard, (5), Actuation Operating pressure Flow *) Test certification IEC 508 *) Model *) G / Flange Solenoid/spring, x *) 0, G / Flange Solenoid/solenoid, , Housing: brass, (5), Actuation Operating pressure Flow *) Test certification IEC 508 *) Model *) G / Flange Solenoid/spring, x, / NPT Flange Solenoid/spring, x,00 05 G / Flange Solenoid/solenoid, ,0 05 / NPT Flange Solenoid/solenoid, ,0 5 5 G / Flange Solenoid/solenoid (APB), ,50 05 / NPT Flange Solenoid/solenoid (APB), ,50 5 Housing: Stainless steel, (5), Actuation Operating pressure Flow *) Test certification IEC 508 *) Model *) G / Flange Solenoid/spring, x, / NPT Flange Solenoid/spring, x, G / Flange Solenoid/solenoid, ,0 05 / NPT Flange Solenoid/solenoid, ,0 5 G / Flange Solenoid/solenoid (APB), ,50 05 / NPT Flange Solenoid/solenoid (APB), ,50 5 *) When ordering please indicate solenoid, voltage and current Models (frequency) *) Since May 008, Date code A8 *) For operation in plants according to IEC 5/508-5 C...+5 C or C see test certificate (on request) *) Test certificate without inlet filter and exhaust guard *) Connecting pipe/fitting: In order to ensure and a pressure collapse avoid the flow, the supply air cross section should with ¼: 8 mm; with ½: 0 mm its. With smaller cross section the inlet should more largely, however at least equally large line at the port its. APB = All Blocked / or 5/ way function (Conversion instructions see page ) / N/en
4 Option selector... Function Substitute 5/ way with spring return 0 (/ way with adapter plate for NAMUR flange) 5/ way impuls (/ way with adapter plate for NAMUR flange) 5/ way with spring return (ABP) Material: Housing/seals Substitute Aluminium/HNBR ( C) Brass/HNBR ( C) Stainless steel/hnbr ( C) Aluminium/NBR ( C) 5 Brass/NBR ( C) Stainless steel/nbr ( C) Special design size Substitute G / 0 / NPT G / / NPT (in connection with version Number code ) APB = All Blocked Air supply Substitute Internal 0 External (only for G /, / NPT Z or low power pilot) Voltage Substitute V d.c V a.c. 0.5 Solenoid Substitute see solenoid table Version Substitute Without manual override (retrofit) 5 Semi automatic (on request) Low power pilot (see page 5) For / NPT + NAMUR (manual override retrofit) N/en /
5 Solenoid operators Power consumption V d.c. 0 V a.c. (W) (VA) Rated current V d.c. 0 V a.c. (ma) (ma) Ex-Protection (ATEX- Categorie) Protection class *),, *5) 8 0 IP00 without connector *5) IP5 with connector *5), IIG IID -, - 8 IIG IID 0,8 - - IIG IID -, - IIG IID 0,8 - - IIG IID 0,8 - - IIG IID -, - IIG IID -, - IIG IID Stainless steel 0,8 IIG IID, IIG IID Ex mb II T *) Ex td A IP T0 Ex mb II T *) Ex td A IP T0 Ex emb II T5/T Ex td A IP T0 *), *0) Ex emb II T5/T Ex td A IP T0 *), *0 Ex dmb IIC T5/T Ex emb II T5/T Ex td A IP T0 *) Ex dmb IIC T5/T Ex emb II T5/T Ex td A IP T0 *) Ex dmb IIC T5/T Ex emb II T5/T Ex td A IP T0 *) Ex dmb IIC T5/T Ex emb II T5/T Ex td A IP T0 *) Ex mb d IIC T/T Ex mb e II T/T Ex td A IP T00 *), *0) Ex mb d IIC T/T Ex mb e II T/T Ex td A IP T00 *), *0), XP/DIP, Div. & Cl. I, Gr. A-D Cl. II / III, Gr. E-G T (0 C) *) NEMA, X,, P,, Standard voltages V d.c., 0 V a.c., other voltages on request. Design according to VDE 0580, EN 500/ % duty cycle. *) EG-Type-Examination-Certificate KEMA 0 ATEX X *) EG-Type-Examination-Certificate KEMA 8 ATEX 5 X *) EG-Type-Examination-Certificate PTB 0 ATEX 085 X *) CSA-LR 5-, FM Approvals *5) Required connector: type 0505 *) Connector cable gland not supplied, see table»accessories«*) IP-Protection class according to EN05 Solenoid actuators for intrinsically-safe circuits Temperature Ambient/ Fluid ( C) Electrical connection DIN EN Form A Circuit diagram Model 0, /5 0 *) m Cable 0, 08 *8) m Cable 0, 0 *8) T T T T T T T T T T T T T T T T Flying leads 50 mm long M0 X,5 *) 0, 0 00 *8) M0 X,5 *) 0, 0 0 *8) / NPT *) 0,8 00 *8) M0 X,5 *) 0,8 0 *8) / NPT *) 0,8 0 *8) M0 X,5 *) 0,8 0 *8) M0 X,5 *), 80 *8), *) M0 X,5 *), 80 *8), *) 0, 8 0 Nominal Min. required Resistance Required Protection Temperature Circuit Model resistance RN coil (Ω) switching current (ma) Rw 0 coil (Ω) voltage at terminal Rw 0 (V) class Ambient/Fluid ( C) diagram Ex ia IIC T , Ex ia IIC T , Ex iad T80 C , Ex iad T00 C , EG-Type-Examination-Certificate PTB 0 ATEX 0 (Kat. II GD) IECEx Certificate of Conformity IECEx PTB 0.00 Cable gland is included in delivery *8) Suitable for outdoor installation *0) IEC Ex Certificate of Conformity *) EG-Type-Examination-Certificate PTB 0 ATEX 05 X Attention: The protection class for coil series xx and 8xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex dmb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex emb. When selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken into acount. Ui = 5 V, Ii = 500 ma, according to Tab. A., EN 00- Pi =,0 W, Li and Ci can be ignored. / N/en
6 Valves, indirect solenoid actuated using low-power pilot system in protection class Ex ia IIC T/T, seals NBR C, (5), Actuation Material Operating pressure Flow *) Model *) G / Flange Solenoid/spring Aluminium, ,5 050 / NPT Flange Solenoid/spring Aluminium, ,5 05 G / Flange Solenoid/solenoid Aluminium, , / NPT Flange Solenoid/solenoid Aluminium, , G / Flange Solenoid/solenoid (APB) Aluminium, , 50 / NPT Flange Solenoid/solenoid (APB) Aluminium, , 5 Valves, indirect solenoid actuated using low-power pilot system in protection class Ex ia IIC T/T, seals HNBR C, (5), Actuation Material Operating pressure Flow *) Model *) G / Flange Solenoid/spring Aluminium, ,5 00 / NPT Flange Solenoid/spring Aluminium, ,5 0 5 G / Flange Solenoid/solenoid Aluminium, ,5 5 0 / NPT Flange Solenoid/solenoid Aluminium, ,5 5 G / Flange Solenoid/solenoid (APB) Aluminium, , 0 / NPT Flange Solenoid/solenoid (APB) Aluminium, , *) When ordering please indicate solenoid, voltage and electrical connection, see below *) Connecting pipe/fitting: In order to ensure and a pressure collapse avoid the flow, the supply air cross section should with ¼: 8 mm; with ½: 0 mm its. With smaller cross section the inlet should more largely, however at least equally large line at the port its. APB = All Blocked / or 5/ way function (Conversion instructions see page ) Low-power pilot system in protection class Ex ia IIC T/T Power P (+0 C) Switch-on voltage U on (+0 C) Switch-on voltage U on (+80 C) Switch-off voltage U off (+0 C) Switch-off voltage U off (-5 C) Rated current I on Resistance coil R (+0 C) Protection class Temperature Ambient Circuit diagram, mw, V 5, V, V, V,5 ma 800 Ω Ex ia IIC T -0 bis +80 C 085, mw V,8 V 5, V, V,5 ma 000 Ω Ex ia IIC T -0 bis +0 C 08 Model *) Max. values Ex i Ui (V) Ii (ma) Pi *5) (mw) *) Category IIG, EG-Type-Examination-Certificate PTB 0 ATEX 00U Air consumption: home position 0 l/h, operating position 5 l/h *5) Model 08 without Pi limiting. Ci and Li can be ignored. *) Connecting pipe/fitting: In order to ensure and a pressure collapse avoid the flow, the supply air cross section should with ¼: 8 mm; with ½: 0 mm its. With smaller cross section the inlet should more largely, however at least equally large line at the port its. Ordering example Valve Pilot, mw Electrical connection 00 internal air supply 005 M x,5 cable gland 0Z external air supply N/en /
7 Accessories Cable gland Protection class Ex e, Ex d (ATEX), Nickel plated brass/ stainless steel Connector Page Thread Cable Ø Material Protection class (ATEX) Model M 0x,5 5,0...8,0 mm Nickel plated brass IIGD Ex e M 0x, mm Nickel plated brass IIGD Ex d /--NPT,5..., mm Nickel plated brass IIGD Ex d M 0x,5,0... mm Stainless steel.5 ( Ti) IIGD Ex e M 0x,5,0... mm Stainless steel.0 ( L) IIGD Ex d 0585 M 0x, mm Stainless steel.0 ( L) IIGD Ex d (with rectifier) Inlet filter Silencer *) Exhaust guard *) Manual override Manual override (for start-up only) Page Page Page Page Page 08 M/S (G/) 0 (G/, / NPT) (without detent) 0 (without detent) C/S (/ NPT) 0 (G/, / NPT) (with detent) M/S (G/) C/S (/ NPT) *) For indoors use only *) For outdoors use Throttle control plate Flange plate, for G/ only Yoke Distance plate for coils Mounting plate 0 and 0 Page 5 Page 5 Page 5 Page 5 Page 5 00 (only for G/) 00 (NAMUR single connection plate) (0 ) 0 (NAMUR-rip use in combination with 00) 055 (0 ) / N/en
8 s Valves,5 5,5 0,5,5 5 8,5,5,5 5 5,, ~,5 5 5,, 5 ~,5 5,, 0,5 ~ 5/ 8,5,5,5,5 8,5 5/ 05,5 0,5,5,5 5/ 0 5,5 Solenoid optional turnable Port G / or / NPT NAMUR connection plate / or 5/ way function N/en /
9 5,5,5,5,5,5,5 8,5 8,5 5/ 5/ 5 A , 5 5 5,5 5 0 External control pressure connection G/8 or /8 NPT Port G/ or / NPT Electrical connection selectable version 005 NAMUR connection plate / or 5/ way function Position of gasket internal pilot air 0 Position of gasket external pilot air C C Electrical connection 005 P ext. C-C P int. 0 / N/en
10 8,5,5,5 5/,5 0 5/ M ,5 0,5 80,5 Solenoid optional turnable External control pressure connection G/8 or /8 NPT Port G/ or / NPT Electrical connection selectable version 005 NAMUR connection plate / or 5/ way function Position of gasket internal pilot air 0 Position of gasket external pilot air Port G/ or / NPT C C P ext. C-C P int. Electrical connection N/en /
11 8 0 5,5,5 5,, ~0 0 0,5,5,5 G/ M5 ~,5,5,5 ~0 Solenoid optional turnable NAMUR connection plate / or 5/ way function / N/en 5..5.
12 ,5,5 5,, 0 0 0,5,5 0,5 G/ 0 0 ~0,5 5,5,5 M5 58,5,5 Solenoid optional turnable NAMUR connection plate / or 5/ way function N/en /
13 s Solenoid operators 5,5 8,5 0,5 0 / - NPT 8 0,5 8 5,5 5,5,5 0,5 8,5 8 M x,5 8,5,5 0 0,5,5,5 0 M 0 x, Connector x 0 turnable Ø (with spacer tube) 5 M0 x,5 or / - NPT Flying leads 50 mm long 8 / N/en 5..5.
14 Circuit diagrams 5 0 NAMUR hole pattern (driving side) Port size G/ Port size G/ M5 5 M Port (A) Coding stud threaded NAMUR quick exhaust module for a better kv-value by exhaust see data sheet M5 & M (0 deep) 5 Port (R) Conversion instructions of 5/ into / way function 5/ way function (original mode of supply) / way function 5/ / / resp. 5/ way function according to version by swapping or turning enclosed adaptor plates. Make sure Marker and Arrow do match as shown on above drawing. Original mode of supply: 5/ function. Arrow Marker N/en /
15 Single connection plate Model: 00 NAMUR slot Model: 0 5,5 M 5 (x),5 0 ø,5 0 5,5 0 G /,5 5 5,5 5,5 5,5 ø 5,5 G / 5 0 Yoke Model: 0505 ø ø,5 Throttle control plate Model: 00,5 5,5 x M ,5 M 5 5,5 B B 5,5 A A / N/en
16 0 Mounting plate Model: 05 0 Mounting plate Model: 055 Distance plate Model: 0500,5 5, M5 M5 0 0 M , Manual override Model: Model: Model: 0 0,5 M0 x 0,5 ~ M0 x 0,5 M0 x 0,5 ~ N/en /
17 Silencer Model: M/S, M/S, C/S, C/S Exhaust guard Model: 0, 0 C C G G ø D B ø D B Model B G C Ø D (g) Model M/S, C/S / 5,5 5,5, 0 M/S, C/S /,5 0 B Suitable for G C Ø D (g) Model / G/, / NPT 0,5 5 0 / G/, / NPT,5 0 Inlet filter Model: 08 G/ G/,5 8,5 8,5 Cable gland C C B A D B A only D A B C ø D Model M0 x, M0 x,5,5, M0 x, /- NPT 5 58,5..., M0 x, M0 x, Warning These products are intended for use in industrial compressed air and fluid systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. / N/en 5..5.
97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free
More information97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT
70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination
More informationTechnical features. 12/ f. N/en
/, / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface Main application: single and double operated actuators TÜV-approval based
More information97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves
970 NAMUR, /, / & / > > Port size: / or / ISO G/NPT > > Main application: single and double operated actuators > > TÜV-approval based on type examination DIN EN, DIN 9 and IEC 08 > > Valves for safety
More information97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7
90 NAMUR /, / and / directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT, G /, / NPT NAMUR-interface For single and double operated actuators
More informationVALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified
More informationHERION SERIES Indirect solenoid actuated spool valves
HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free
More information/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface
9805 / way indirect solenoid operated valves G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to SIL (IE 6508) dd-on manual
More informationOperating pressure (bar)
/ poppet valves electromagnetic actuated, directly controlled G /4, /4 NPT, G /, / NPT or flanged with NAMUR Interface Main application: single operated actuators for plants Valves for safety systems up
More information98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface
9805 NMUR / poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to
More informationOperating pressure. N/en/en
660, 8007 NAMUR /, / & / spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple design
More informationOperating pressure. N/en/en
660, 8007 NAMUR /, / & / way spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple
More informationMaterial Seat seal. N/en
0 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR interface TÜV-approval based on IEC 6 8 Valves for safety systems up to SIL Standard NAMUR type - redundancy:
More informationFlow. Flow. N/en
/ poppet valves electromagnetic actuated, directly controlled G /4 or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to, 0 - mbar For a.c. solenoid systems with integrated
More information97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >
More information3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface
9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based
More informationMaterial pressure (bar) (Cv (US) kv x 1,2 Seat
00 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V Valves for safety systems up to SIL Solenoid valve also
More information3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface
9805 / Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G/, / NPT or flanged with NMUR interface Main application: single operated process actuators TÜV-approval
More information97105 Inline direct pneumatically actuated 3/2 and 5/2 spool valves G 1/4.G1/2, 1/4 NPT 1/2 NPT
direct pneumatically actuated 3/ and 5/ spool valves G /.G/, / NPT / NPT For single and double operated actuators Valves for safety systems up to SIL () Crossover-free switching, switch-over function guaranteed
More informationOperating pressure (bar) kv factor (m 3 /h) *3)
/ way poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar
More information26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.
66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual
More information26360, NAMUR. Technical data
66, 87 NAMUR /-, /- and / directional control valves Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G/ NAMUR-Interface For single and double operated actuators Manual
More information97105 Inline, 3/2 & 5/2 Direct pneumatically actuated spool valves
9705 Inline, 3/ & 5/ > > : /... / (ISO G/NPT) > > Main application: single and double operated actuators > > Valves for safety systems multi-channel up to SIL 3 > > Crossover-free switching > > TÜV-approval
More information6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
L Inline & NMUR series, / & / > Port size: / (ISO /NPT) or flanged with NMUR interface > Suited for outdoor use under critical environment conditions (see solenoid list) > Variable valve solenoid combination
More informationFlow. (l/min) (ms) N/en
66, 87 Inline / & / spool valves electromagnetic actuated, indirectly controlled G / & G / For single and double operated actuators Manual override with and without detent imple design of soft seal spool
More information80265 series, 3/2 Indirect solenoid actuated poppet valve
> > Port size: G/... G > > High flow rate > > Optionally air pilot operated > > High repeatability of switching time > > Variable valve solenoid combination Technical features Medium: Compressed air, filtered,
More information24011 series, 3/2 Direct solenoid actuated poppet valve
0 series, / > Port size: / (ISO G or NPT), NAMUR Interface > Add-on manual override or inductive limit switches on request > Main application: Single and double acting actuators > TÜV-approval based on
More information95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves
9500, / (stainless steel) > > Port size: G/8, G/4, /4 NPT > > Working from 0 bar up > > Assembled free of oil and grease > > Suited for fine vacuum down to,33 0 - mbar > > For a.c. solenoid systems with
More information21023, 21025, 2/2 Direct solenoid actuated poppet valves
03, 05, / > > Port size: G/4, G/ > > Working from 0 bar up > > Suitable for mediumhigh vacuum down to.33 0 - mbar l/s > > Compact design > > Valves and solenoids are ATEX approved. Additional international
More informationSeries 95000, 2/2 Direct solenoid actuated poppet valve
> Port size: /4 (ISO G or NPT), G/ > Working from 0 bar up > Short switching times > Suited for fine vacuum down to,33 x 0 - mbar > For a.c. solenoid systems with integrated rectifier (40... 60 Hz) > Variable
More informationV88 series Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability
oo Safety, oo Availability and oo Safety and Availability > > Semi modular design - Maxseal valves > > Stainless steel visual indicators and exhaust guards as standard > > able terminations inside coil
More informationV88 series Redundant valve manifold systems - Semi modular 2oo2 Availability
oo Availability > > Semi modular design - Maxseal valves > > Stainless steel visual indicators and exhaust guards as standard > > able terminations inside coil housing > > International approvals > > Stainless
More information98015 series, 3/2 Direct solenoid actuated poppet valve
90 series, / > Port size: / & / (ISO G/NPT), NAMUR Interface > Main application: Single acting actuators > TÜV-approval based on type eamination DGRL 9//EG and IE 0, multichannel up to SIL > Optional add-on
More information26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves
66, 87, /, 5/ & 5/ > > Port size: G/ & G/ > > Compact design > > Easily interchangeable solenoid > > tandard manual override > > ll valves available with Ex protected coils (TEX or other international
More informationG 1/2 30,5 A Brass NBR 0,8 3,
4/2 way poppet valves electromagnetic actuated, directly controlled /4 & /2 Working from 0 bar up Suitable for vacuum range down.33 0-2 mbar l/s Protection class : IP 65, Ex em, Ex d TEX approved (see
More informationV87 series - Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability
V87 series - Redundant valve manifold systems - Semi modular oo Safety, oo Availability and oo Safety and Availability > > Semi modular design - Herion valves > > Stainless steel visual status indicators
More informationICO3S - 2/2, 3/2 or 5/2 poppet valves Electromagnetically actuated, direct solenoid operated
ICOS - /, / or / poppet valves > > Port size: /... / (ISO G / NPT) Namur or manifold > > Control of pneumatic or hydraulic operated equipment > > Direct acting solenoid valve > > High flow > > bar inlet
More informationSPCH/ Big bottle blowing block
> > Blowing block for linear and rotating blow moulding machines > > Digital position indicator - counter with four decade from 000.0 to 00.0 > > Best suited for PET bottles from 5 up to 30 litres (up
More information21D Allfluid pressure switch, electromechanically actuated
D > > 0,... 0, bar (0,... psi), G/, / NPT > > High accuracy > > High number of switching cycles > > Microswitch approved by UL and CSA > > Fixed or adjustable hysteresis > > Shock and vibration tested
More informationISO*STAR (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves
*STR (SX, SXP) / & / > > Sub-base mounted, 99- s, or > > Specially coated glandless spool and sleeve for long trouble-free life > > Integral flow regulators available on and s for cylinder speed control
More informationSCVA08, SCVA10, SCVA20 & SCVA32, 3/2 Solenoid actuated safety valve
SCV0, SCV0, SCV & SCV, / > > Port size: /4, /, /4 and (ISO G, NPT) > > Range of sizes - DN, 0, and > > Redundant valve assembly, pneumatic self monitoring with integrated safety silencer > > Ensures safe
More informationISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves
*STR - TX version (SX, SXP) / & / > > Sub-base mounted, 99- s, or > > Specially coated glandless spool and sleeve for long trouble-free life > > Integral flow regulators available on and s for cylinder
More informationStandardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.
Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled
ICO4S /, / or 5/ poppet valves > > Port size: /4... /4 (ISO G/NPT) or manifold version > > Reliable and long life, ideal for a one time installation > > Direct acting solenoid valve for the control of
More information26230, Inline 3/2, 5/2 and 5/3 way soft seal spool valves electromagnetic actuated, indirectly controlled G 1/4, G 1/2
/, / and / way soft seal spool valves electromagnetic actuated, indirectly controlled /, / traight-through flow, high v-factor tandard manual override ompact design asily interchangeable solenoid system
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More information4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F
4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to
More information5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4
5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4 Products 5/2 Directional-control valve, single valve, electrical connection M8 (4 poles) 5/3 Directional-control valve, single valve, electrical
More informationSeries 3730 Type Electropneumatic Positioner
Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner
More informationSideControl Positioner
SideControl Positioner Electropneumatic positioner for pneumatically actuated process valves II (1) 2 G EEx ia IIC T6 approval can be combined with... Type 2712 Globe valve Globe valve acc. to NAMUR/IEC
More informationApplication The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.
DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof
More informationSeries 3730 Electropneumatic Positioner Type
Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm
More informationV03, V04 and V05 Series
V03, V04 and V05 Series / and 3/ Poppet Valves Electrically Actuated G 1 8, G 1 4, CNOMO and Interface Extensive range of power and orifice size options Removable coil Manifold rail for 1 to 0 valves Operating
More informationSensor boxes SRBC. Festo core product range Covers 80% of your automation tasks
Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity
More informationPneumatic Control Unit for the integrated mounting on process valves
Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More information60 series, 2/2 or 3/2 Ball valve
>> Port size: Rp/..., /... >> Ideally suited for most general purpose applications >> Easy installation, simple operation and maintenance free >> -way ball valves with actuator interface conforming to
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationAssembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail
Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL
More informationDigital Output Module 8-Channel Version for Zone 1 Series 9475/
www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationLMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.
LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:
More informationSeries 3730 Type Electropneumatic Positioner
Series 3730 Type 3730- Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99
More informationDMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationInductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position
More informationDigital Positioner 8049
Compact digital positioner for pneumatic control valves. Positioner can be integrated into valve actuator (no external moving parts for stroke feedback) Wide range of strokes - 8 mm No steady-state air
More informationInductive sensor BI1.5-EG08-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationGeneral Specifications
General Specifications Model RAGH Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. The mounting position is
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)
More informationInductive sensor BI1.5-EG08-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationData Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication
Data Sheet T 8493 EN Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,
More informationSeries 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication
Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic on/off valves in safety-instrumented systems.
More informationInductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting
More informationSeries 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication
Series 3730 Electropneumatic Positioner Type 3730-4 with PROFIBUS-PA communication Application Positioner for attachment to pneumatic control valves Travels 3.6 to 200 mm Opening angle 24 to 100 Smart,
More informationOperating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015
Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in
More informationSeries Panel Mounted Control Devices
E_Master2012.qxd:NEW_E_Master_temp.qxd 1/27/12 4:28 PM Page 1 Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2"
More informationT EN TROVIS Electropneumatic Positioner
T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.
More informationElectropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s
ElectroPneumatic Miniature Control Valves Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com /47 Electropneumatic miniature control valves Mounting Connectors Minisolenoid
More informationRM/28000/M, ISO cylinder Magnetic piston, single acting
> > Ø 0... 5 mm > > Standard magnetic piston for full control system versatility > > Nose mounting nut and piston rod locknut as standard > > Conforming to ISO > > Optional port arrangement for compact
More informationGeneral Specifications
General Specifications Model RAGH Rotameter 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com This type of Rotameter is designed
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationPROFIBUS-PA Positioner Type 3785
PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,
More informationIndicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED
Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure
More informationControl head for hygienic process valves
for hygienic process valves Type can be combined with... Universal attachment for hygienic process valves Contactless position measurement system with 3 switching points (Teach-In function) Coloured status
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8696 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact
More informationM/60100/M, Slide units Magnet piston, double acting
M/000/M, Slide units > > Ø 0... 0 mm > > High quality sliding bearings ensure long durable life and high guidance performance > > Easy to install-reduces costly design time > > Double piston rod provides
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Automatic teach function Contact-free position sensor Compact stainless steel design AS-Interface
More informationSeries 3730 Electropneumatic Positioner Type with HART communication and pressure sensors
Series 3730 Electropneumatic Positioner Type 3730-6 with HART communication and pressure sensors Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,
More informationRM/92000/M, Short stroke cylinder Magnetic piston, double acting
> Ø... 00 mm > One third the basic length of a corresponding ISO/VDM model > Fully non-corrodible specification > Standard magnetic piston for full control system versatility > Low friction, long life
More informationControl Head for the integrated mounting on process valves
Control Head for the integrated mounting on process valves Type can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationFloat Switches with Permanent Magnet For Vertical Installation Model RSM
Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring
More informationExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)
Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC
More information