SINGLE Technical Data Book. SINGLE for Europe (R410A, HP)

Size: px
Start display at page:

Download "SINGLE Technical Data Book. SINGLE for Europe (R410A, HP)"

Transcription

1 SINGLE Technical Data Book SINGLE for Europe (RA, HP)

2 History Ver.. Release Single TDB for Europe.. Ver.. Add tcoe data (Specifications).. 9 Ver.... 9

3 CAC - World-class energy efficiency Maintain optimal comfort and control with energy and cost-efficient technologies Featuring a suite of energy-optimizing technologies, Samsung CAC Single delivers top-class energy efficiency to support business in saving costs and the environment. Plus, CAC Single with its smart technologies fully complies with new European Union (EU) regulations for more efficient performance. Small package, big performance The Samsung Ceiling Type air conditioner boasts a slim, compact design half the size of conventional products with cooling power comparable to larger units. Up to percent less energy use After reaching changes its operation mode to economical. By avoiding inefficient and frequent switching on and off of the compressor, the digital inverter saves up to percent in energy consumption compared to non-inverter air conditioners. Non-inverter M Instead of connecting just one indoor unit, users can connect two, three or four indoor units with a single outdoor unit for more efficient cooling and heating. The indoor units operate and are controlled simultaneously as one cycle within the same mode via one remote controller for up to four rooms. This system is ideal for spaces requiring multiple indoor units, such as openplan offices or shops. as per EU Directive //EU Q Smart inverter technology offers powerful, quick cooling and heating with minimal electricity consumption, which means real cost savings and less energy waste. The EU has established new regulations to drastically cut the power consumption of air conditioners. Inefficient units will be gradually withdrawn from the market starting in. To further support this initiative, the EU is introducing an improved energy labeling system to provide consumers a better idea of how much electricity their units consume. Outdoor Unit Capacity Rooms Rooms Rooms 7.kW. +. kw. +. kw. +. kw

4 Features & Benefits CAC Single - Superior performance Stabilize the atmosphere with broad temperature allowance and control Samsung is dedicated to supporting comfortable living and working environments based on the strength of its technologies. With a single unit, CAC Single delivers reliable comfort and control over multiple areas to ensure a pleasant atmosphere in any climate. V!!"# " $" CAC Single outdoor units offer a selection of pipe directions. The internal pipe connection ports allow four different pipe directions, supporting a neater, more organized-looking unit upon installation. Wide temperature performance No matter how extreme the temperature, the highperforming CAC Single can handle the conditionwithout the need for an additional unit. Featuring a wide temperature allowance, it can cool in heat of up to ensure a constant and comfortable home environment. Ideal comfort in minutes The CAC Single digital inverter air conditioner works at maximum capacity at startup. As soon as the temperature reaches the desired or set temperature, CAC Single performs fine adjustments to cope with any changes. This means less temperature fluctuation and ideal comfort in a matter of minutes.

5 I*+,,-.*/ Model Name AC M N D K H EU 9 :9 ;9 <9 =9 BCDEG () Classification A& () Capacity CAC x / kw ( digits) () Product Notation Way Cassette Way Cassette (x) Way Cassette, Cassette L LSP Duct M MSP Duct C Ceiling J Console A A (Wall Mounted) () Version ' J M 7 () Feature F S P Flagship Standard Deluxe Premium () Product Type ( Indoor Unit Outdoor Unit (7) Rating Voltage ) () Mode ' %

6 Nomenclature Outdoor Unit Model Name AC M X A D K H EU 9 :9 ;9 <9 =9 BCDEG HJK Classification () Product Notation A& CAC A Inv+Side+General Temp () Capacity X / kw ( digits) () Feature F S P Flagship Standard Deluxe Premium () Version ' J M 7 (7) Rating Voltage ) () Product Type ( Indoor Unit Outdoor Unit () Mode '

7 Line-up Indoor unit NOPRS Way CST TUWX YZ[ (x) TUWX YZ[ \]^ YZ[ _Z` abcd efg hijk Ylmnlop Ypqoqmr stuu eviwkxy z{ x }~+,,-.*/ NOPRS Phase \`Wnp L

8 Line-up DPM (Digital Pack Multi) ƒ - - ACMXAD - - ACMXAD - - ACMXAD ACMXAD - ACMXAD ACMXAD ACMXAD - - ACMXAD - - ACMXAD - ACMXAD ACMXAD - ACMXAD - ACMXAD ACMXAD - ACMXAD ACMXAD

9 Line-up ƒ - - ACMXAD - ACMXAD - ACMXAD ACMXAD - - ACMXAD - - ACMXAD ACMXAD - ACMXAD - ACMXAD - - ˆ Š Œ MXJ-D9K MXJ-D9K MXJ-D9K Ž Max. pipe length after DPM kit m Max. pipe length difference between IDUs after DPM kit m Max. distance between IDUs m Max. height difference between IDUs.m * Indoor units should be installed in one area which is not divided by a wall

10 MSP Duct. Specification. Summary Table 7. Capacity Table. Dimensional Drawing 7. Center of Gravity 7. Electrical Wiring Diagram 7 7. Sound Data 7. Fan Characteristics 79

11 Features & Benefits Duct S Overview Samsung Ducted Type air conditioning units are a smart solution for low-maintenance, consistent cooling and heating performance in any environment. Their compact, slim frame blends seamlessly into ceilings, enhancing the beauty of the interior space and affording users more flexible installation options. Offering a comprehensive lineup, Samsung Ducted Type air conditioning units offer just the right solution for every need--from the office or shop to the restaurant kitchen. Experience performance and convenient comfort for any weather condition Samsung Duct S delivers unparalleled cooling and heating and flexible management with customizable comfort settings in any climate all year round. Plus, it boasts a slim, compact size and multiple access points for easy setup exactly where needed. Smart pressure control Samsung Ducted Type units feature a smart pressure control system. This system adjusts the fan speed based on the (ESP), delivering consistent cooling and heating power, regardless of the surrounding environment. Convenient installation The optional lift-up drain pump lifts condensed water up to 7 mm, compared to a limit of 7 mm on conventional models, for flexible and convenient installation. š œ žžÿ Ÿ žœ žœ œ œ Ÿ žž consistent operation and convenience with features such as: Efficient operation. Stage the desired atmosphere with energy-efficient performance and customized airflow. Smart management. Cool spaces efficiently and manage the air conditioning unit even while away, with features designed for efficiency and control. Easy, flexible setup. Install and maintain even multiple units with a compact and easily accessible design.

12 . Specification MSP Duct ª««Mode - kw. /. /.9. /. /.. /. / 7. Btu/h, /,9 /,, / 7, /,, / 9, /,9 kw. /. /.7. /. / 7.. / 7. /. Btu/h, /, /,, /, /,, /,9 / 9, kw. /. /.. /. /.. /.9 /. kw. /. /.. /. /.7. /.9 /. A. /. / 7.. / 7. /.. /. /. A. /. /..7 / 7. /.. /. /. MCA A... MFA A. W/W...97 W/W...9 W/W. (A++). (A++). (A++) W/W. (A+). (A+). (A+) kw... Type Flare connection Flare connection Flare connection... / / / Type Flare connection Flare connection Flare connection / / / - Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes m m m m mm mm Min..7 Min..7 Min..7 - F, F F, F F, F - Both indoor and outdoor unit Both indoor and outdoor unit Both indoor and outdoor unit - RA RA RA. /.9. /.7. /.7

13 MSP Duct Indoor Unit ª««,, -,,, -,,, -, - Fin & Tube Fin & Tube Fin & Tube - Al Al Al - Cu Cu Cu - Sirocco Fan Sirocco Fan Sirocco Fan EA CMM. / 9. /.. /. / /. /. l/s 7. /. /..7 /. /.. /. /. mmaq /./ /./ /./ Pa //7 /9/7 /9/7 W x n x x x VP-(OD, ID) VP-(OD, ID) VP-(OD, ID) db(a) / / 9 / / / 7 / db(a) kg... kg... mm x x 7 x x 7 x x 7 mm x x 7 x x 7 x x 7 - EGI Steel Plate EGI Steel Plate EGI Steel Plate - - MWR-WEN / MWR-WEN MWR-WEN / MWR-WEN MWR-WEN / MWR-WEN mm / Liter/h MDP-G7SP MDP-G7SP MDP-G7SP - MDP-G7SQ MDP-G7SQ MDP-G7SQ mm / Liter/h 7/ 7/ 7/ - Removable / Washable Removable / Washable Removable / Washable

14 . Specification MSP Duct ª««,, -,,, -,,, -, - Fin & Tube FMC FMC - Al Al Al - Cu Al Al - Anti-Corrosion UG9AJ9FER UG9TKFE UG9TKFE kw... - POE POE POE cc - Propeller Propeller Propeller - Front Front Front EA CMM l/s BLDC Motor BLDC Motor BLDC Motor W x n x x x db(a) 9 db(a) 9 db(a) kg... kg mm 79 x x x x x x mm 9 x x x 7 x x 7 x - EGI Steel Plate EGI Steel Plate EGI Steel Plate ²³ µ Specification may be subject to change without prior notice. Specification comply with EN. ) Capacities are based on (Equivalent refrigerant piping m, Level differences m); - Cooling : Indoor temperature 7 C DB, 9 C WB / Outdoor temperature C DB, C WB - ) Sound power level is an absolute value that a sound source generates. Sound power level is based on cooling operation. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound values are obtained in an anechoic room. Sound values of multi combination are theoretical values based on sound results of individual installed units. ) These products contain RA(GWP=,) which is fluorinated greenhouse gas. In case you want to know more information regarding capacity and correction, please refer to capacity table TDB on pvi.samsung.com site. ±

15 MSP Duct ª««Mode - kw. / 7. /.. / 9. /.. / 9. /. Btu/h 7, /, / 7,, /,7 /,, /,7 /, kw.9 /. / 9.. /. /.9. /. /.9 Btu/h, / 7, /,7 7, /, / 7, 7, /, / 7, kw. /. /.9. /.9 /.. /.9 /. kw. /. /.9. /.7 /.. /.7 /. A. / 9.7 / 7.. /.7 / 9.. /. / 7. A. /. / 7.. /. /.7. /. / 9. MCA A... MFA A. W/W... W/W... W/W. (A++).9 (A+).9 (A+) W/W. (A+). (A+). (A+) kw.7.. Type Flare connection Flare connection Flare connection / / / Type Flare connection Flare connection Flare connection... / / / - Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes m m m m mm mm Min..7 Min..7 Min..7 - F, F F, F F, F - Both indoor and outdoor unit Both indoor and outdoor unit Both indoor and outdoor unit - RA RA RA. /.. /.. /.

16 . Specification MSP Duct Indoor Unit ª««,, -,,, -,,, -, - Fin & Tube Fin & Tube Fin & Tube - Al Al Al - Cu Cu Cu - Sirocco Fan Sirocco Fan Sirocco Fan EA CMM 7. /. /.. /. /.. /. /. l/s. /. /..7 /.7 /.7.7 /.7 /.7 mmaq /./ /./ /./ Pa /9/7 /9/7 /9/7 W x n x x x VP-(OD, ID) VP-(OD, ID) VP-(OD, ID) db(a) / 7 / / / / / db(a) kg... kg. 9 9 mm x x 7 x x 7 x x 7 mm x x 7 9 x x x x EGI Steel Plate EGI Steel Plate EGI Steel Plate - - MWR-WEN /MWR-WEN MWR-WEN / MWR-WEN MWR-WEN / MWR-WEN mm / Liter/h MDP-G7SP MDP-G7SP MDP-G7SP - MDP-G7SQ MDP-G7SQ MDP-G7SQ mm / Liter/h 7/ 7/ 7/ - Removable / Washable Removable / Washable Removable / Washable

17 MSP Duct ª««,, -,,, -,,, -, - FMC Fin & Tube Fin & Tube - Al Al Al - Al Cu Cu - UGTFUAE UGTFUBJU UGTFUCJU kw POE PVE PVE cc - Propeller Propeller Propeller - Front Front Front EA CMM 7 7 l/s - BLDC Motor BLDC Motor BLDC Motor W x n x x x db(a) 9 db(a) db(a) kg 7 7 kg mm x 79 x 9 x 99 x 9 x 99 x mm x 9 x 99 x 9 x 99 x 9 x - EGI Steel Plate EGI Steel Plate EGI Steel Plate ²³ µ Specification may be subject to change without prior notice. Specification comply with EN. ) Capacities are based on (Equivalent refrigerant piping m, Level differences m); - Cooling : Indoor temperature 7 C DB, 9 C WB / Outdoor temperature C DB, C WB - ) Sound power level is an absolute value that a sound source generates. Sound power level is based on cooling operation. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound values are obtained in an anechoic room. Sound values of multi combination are theoretical values based on sound results of individual installed units. ) These products contain RA(GWP=,) which is fluorinated greenhouse gas. In case you want to know more information regarding capacity and correction, please refer to capacity table TDB on pvi.samsung.com site.

18 . Specification MSP Duct ª««Mode - kw. /. /.. /. /.. /. /. Btu/h, /, /,9, /, /,9, /,9 /, kw. /. /.. /. /.. /. / 7. Btu/h 7, /, /,9 7, /, /,9, /, /, kw. /. /.7. /. /.7.9 /. /. kw. /. /.. /. /..7 /. /.9 A. /. /.. /. / 7.. / 9. /. A. /. /.. /.9 /.. / 7. /. MCA A... MFA A. W/W...7 W/W.9.9. W/W. (A+). (A+). (A+) W/W. (A+). (A+). (A+) kw.. 7. Type Flare connection Flare connection Flare connection / / / Type Flare connection Flare connection Flare connection... / / / - Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes m m m m mm mm Min..7 Min..7 Min..7 - F, F F, F F, F - Both indoor and outdoor unit Both indoor and outdoor unit Both indoor and outdoor unit - RA RA RA. /.. /.. /.

19 MSP Duct Indoor Unit ª««,, -,,, -,,, -, - Fin & Tube Fin & Tube Fin & Tube - Al Al Al - Cu Cu Cu - Sirocco Fan Sirocco Fan Sirocco Fan EA CMM. /. /.. /. /.. /. /. l/s.7 /.7 /.7.7 /.7 /.7. /.7 /. mmaq /./ /./ /./ Pa /9/7 /9/7 //7 W x n x x x VP-(OD, ID) VP-(OD, ID) VP-(OD, ID) db(a) / / / / 7 / / db(a) kg... kg 9 9. mm x x 7 x x 7 x x 7 mm 9 x x x x x 7 x EGI Steel Plate EGI Steel Plate EGI Steel Plate - - MWR-WEN / MWR-WEN MWR-WEN / MWR-WEN MWR-WEN / MWR-WEN mm / Liter/h MDP-G7SP MDP-G7SP MDP-G7SP - MDP-G7SQ MDP-G7SQ MDP-G7SQ mm / Liter/h 7/ 7/ 7/ - Removable / Washable Removable / Washable Removable / Washable

20 . Specification MSP Duct ª««,, -,,, -,,, -, - Fin & Tube Fin & Tube Fin & Tube - Al Al Al - Cu Cu Cu - UGTFUBJU UGTFUCJU UGTKFJX kw PVE PVE PVE cc 7 - Propeller Propeller Propeller - Front Front Front EA CMM l/s - BLDC Motor BLDC Motor BLDC Motor W x n x x x db(a) db(a) db(a) kg kg mm 9 x 99 x 9 x 99 x 9 x 99 x mm 99 x 9 x 99 x 9 x 99 x 9 x - EGI Steel Plate EGI Steel Plate EGI Steel Plate ²³ µ Specification may be subject to change without prior notice. Specification comply with EN. ) Capacities are based on (Equivalent refrigerant piping m, Level differences m); - Cooling : Indoor temperature 7 C DB, 9 C WB / Outdoor temperature C DB, C WB - ) Sound power level is an absolute value that a sound source generates. Sound power level is based on cooling operation. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound values are obtained in an anechoic room. Sound values of multi combination are theoretical values based on sound results of individual installed units. ) These products contain RA(GWP=,) which is fluorinated greenhouse gas. In case you want to know more information regarding capacity and correction, please refer to capacity table TDB on pvi.samsung.com site.

21 MSP Duct ª««Mode - kw. /. /.. /. /.. /. /. Btu/h, /,9 /,,9 /,7 /,9,9 /,7 /,9 kw. /. / 7.. /. /.. /. /. Btu/h, /, /,,9 /,9 /,,9 /,9 /, kw.9 /. /.. /. /.. /. / 7.9 kw.7 /. /.9.7 /. / 7..7 /. / 7.9 A.9 / 7. /..7 /. /.. / 7. /. A. /. / 9.. / 9. /..9 / 7. /. MCA A... MFA A.. W/W.7.. W/W... W/W. (A+).. W/W. (A+).. kw Type Flare connection Flare connection Flare connection / / / Type Flare connection Flare connection Flare connection... / / / - Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes m m 7 7 m m mm mm Min..7 Min..7 Min..7 - F, F F, F F, F - Both indoor and outdoor unit Both indoor and outdoor unit Both indoor and outdoor unit - RA RA RA. /.. / 7.. / 7.

22 . Specification MSP Duct Indoor Unit ª««,, -,,, -,,, -, - Fin & Tube Fin & Tube Fin & Tube - Al Al Al - Cu Cu Cu - Sirocco Fan Sirocco Fan Sirocco Fan EA CMM. /. /.. /. /.. /. /. l/s. /.7 /.. /.7 /.. /.7 /. mmaq /./ /./ /./ Pa //7 //7 //7 W x n x x x VP-(OD, ID) VP-(OD, ID) VP-(OD, ID) db(a) 7 / / 7 / / 7 / / db(a) kg... kg... mm x x 7 x x 7 x x 7 mm 9 x 7 x x 7 x x 7 x EGI Steel Plate EGI Steel Plate EGI Steel Plate - - MWR-WEN / MWR-WEN MWR-WEN / MWR-WEN MWR-WEN / MWR-WEN mm / Liter/h MDP-G7SP MDP-G7SP MDP-G7SP - MDP-G7SQ MDP-G7SQ MDP-G7SQ mm / Liter/h 7/ 7/ 7/ - Removable / Washable Removable / Washable Removable / Washable

23 MSP Duct ª««,, -,,, -,,, -, - Fin & Tube Fin & Tube Fin & Tube - Al Al Al - Cu Cu Cu - UGTKFJX UGTKFJX UGTKFJX kw PVE PVE PVE cc Propeller Propeller Propeller - Front Front Front EA CMM 7 l/s - BLDC Motor BLDC Motor BLDC Motor W x n x x x db(a) db(a) db(a) kg kg mm 9 x 99 x 9 x x 9 x x mm 99 x 9 x 99 x x 99 x x - EGI Steel Plate EGI Steel Plate EGI Steel Plate ²³ µ Specification may be subject to change without prior notice. Specification comply with EN. ) Capacities are based on (Equivalent refrigerant piping m, Level differences m); - Cooling : Indoor temperature 7 C DB, 9 C WB / Outdoor temperature C DB, C WB - ) Sound power level is an absolute value that a sound source generates. Sound power level is based on cooling operation. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound values are obtained in an anechoic room. Sound values of multi combination are theoretical values based on sound results of individual installed units. ) These products contain RA(GWP=,) which is fluorinated greenhouse gas. In case you want to know more information regarding capacity and correction, please refer to capacity table TDB on pvi.samsung.com site.

24 . Summary Table MSP Duct ¹ Žº» ¼½º º ¾ ¾ ÀÁÂà ÄÀÁ Max /. Std... Mid 9. / 9. - Min... Low. /. - Max /. 9 Std... Mid. /. - Min... Low 9. / 9. - Max / 7. Std.. 7. Mid. /. 7 - Min... Low. /. - Max / 7. Std. 7.. Mid. /. 7 - Min...9 Low. /. - Max...9. /. Std. 9.. Mid. /. - Min... Low. /. - Max.... /. Std... Mid. /. - Min... Low. /. - Max /. 7 Std... Mid. /. - Min... Low. /. - Max.... /. 7 Std... Mid. /. - Min... Low. /. - ²³ µ Sound data is based on cooling operation. ÀÁÂà to to 9... to 9... to 9... to 9... to to 9... to to 9... to to 9... to ²³ µ MCA : Minimum circuit amperes MFA : Maximum fuse amperes Select wire size based on the value of MCA ±

25 MSP Duct ÅÆÇ ÈÉÊËÌÍÎÍÏÐÑÒÓÔ Õ ÈÉÊËÌÍÖÈÏÐÑÒÓÔ Cooling Ø Ù ÚÛÜÝ ØÜÞÜßàÛáâ ãäø Ù ãåæçàèýå äåüû ØÜÞÜßàÛáâ éê Ù éúëåì êæþíû Heating îï ð îñòóô ïóõóö òøù úû ð úñüýþ ûÿõtò ²³ µ Capacities are based on following conditions; Refrigerant pipe length : m / Level difference : m.

26 . Capacity Table MSP Duct () ACMNMDKH/EU + ACMXADKH/EU Cooling Ø Ù ÚÛÜÝ ØÜÞÜßàÛáâ ãäø Ù ãåæçàèýå äåüû ØÜÞÜßàÛáâ éê Ù éúëåì êæþíû Heating îï ð îñòóô ïóõóö òøù úû ð úñüýþ ûÿõtò ²³ µ Capacities are based on following conditions; Refrigerant pipe length : m / Level difference : m.

27 MSP Duct () ACMNMDKH/EU + ACMXADKH/EU Cooling Ø Ù ÚÛÜÝ ØÜÞÜßàÛáâ ãäø Ù ãåæçàèýå äåüû ØÜÞÜßàÛáâ éê Ù éúëåì êæþíû Heating îï ð îñòóô ïóõóö òøù úû ð úñüýþ ûÿõtò ²³ µ Capacities are based on following conditions; Refrigerant pipe length : m / Level difference : m.

28 . Capacity Table MSP Duct () AC7MNMDKH/EU + AC7MXADKH/EU Cooling Ø Ù ÚÛÜÝ ØÜÞÜßàÛáâ ãäø Ù ãåæçàèýå äåüû ØÜÞÜßàÛáâ éê Ù éúëåì êæþíû Heating îï ð îñòóô ïóõóö òøù úû ð úñüýþ ûÿõtò ²³ µ Capacities are based on following conditions; Refrigerant pipe length : m / Level difference : m.

29 MSP Duct () AC9MNMDKH/EU + AC9MXADKH/EU Cooling Ø Ù ÚÛÜÝ ØÜÞÜßàÛáâ ãäø Ù ãåæçàèýå äåüû ØÜÞÜßàÛáâ éê Ù éúëåì êæþíû Heating îï ð îñòóô ïóõóö òøù úû ð úñüýþ ûÿõtò ²³ µ Capacities are based on following conditions; Refrigerant pipe length : m / Level difference : m.

30 . Capacity Table MSP Duct () AC9MNMDKH/EU + AC9MXADNH/EU Cooling Ø Ù ÚÛÜÝ ØÜÞÜßàÛáâ ãäø Ù ãåæçàèýå äåüû ØÜÞÜßàÛáâ éê Ù éúëåì êæþíû Heating îï ð îñòóô ïóõóö òøù úû ð úñüýþ ûÿõtò ²³ µ Capacities are based on following conditions; Refrigerant pipe length : m / Level difference : m.

31 MSP Duct (7) ACMNMDKH/EU + ACMXADKH/EU Cooling Ø Ù ÚÛÜÝ ØÜÞÜßàÛáâ ãäø Ù ãåæçàèýå äåüû ØÜÞÜßàÛáâ éê Ù éúëåì êæþíû Heating îï ð îñòóô ïóõóö òøù úû ð úñüýþ ûÿõtò ²³ µ Capacities are based on following conditions; Refrigerant pipe length : m / Level difference : m.

32 . Capacity Table MSP Duct () ACMNMDKH/EU + ACMXADNH/EU Cooling Ø Ù ÚÛÜÝ ØÜÞÜßàÛáâ ãäø Ù ãåæçàèýå äåüû ØÜÞÜßàÛáâ éê Ù éúëåì êæþíû Heating îï ð îñòóô ïóõóö òøù úû ð úñüýþ ûÿõtò ²³ µ Capacities are based on following conditions; Refrigerant pipe length : m / Level difference : m.

33 MSP Duct (9) ACMNMDKH/EU + ACMXADKH/EU Cooling Ø Ù ÚÛÜÝ ØÜÞÜßàÛáâ ãäø Ù ãåæçàèýå äåüû ØÜÞÜßàÛáâ éê Ù éúëåì êæþíû Heating îï ð îñòóô ïóõóö òøù úû ð úñüýþ ûÿõtò ²³ µ Capacities are based on following conditions; Refrigerant pipe length : m / Level difference : m.

34 . Capacity Table MSP Duct () ACMNMDKH/EU + ACMXADNH/EU Cooling Ø Ù ÚÛÜÝ ØÜÞÜßàÛáâ ãäø Ù ãåæçàèýå äåüû ØÜÞÜßàÛáâ éê Ù éúëåì êæþíû Heating îï ð îñòóô ïóõóö òøù úû ð úñüýþ ûÿõtò ²³ µ Capacities are based on following conditions; Refrigerant pipe length : m / Level difference : m. ±

35 MSP Duct () ACMNMDKH/EU + ACMXADKH/EU Cooling Ø Ù ÚÛÜÝ ØÜÞÜßàÛáâ ãäø Ù ãåæçàèýå äåüû ØÜÞÜßàÛáâ éê Ù éúëåì êæþíû Heating îï ð îñòóô ïóõóö òøù úû ð úñüýþ ûÿõtò ²³ µ Capacities are based on following conditions; Refrigerant pipe length : m / Level difference : m.

36 . Capacity Table MSP Duct () ACMNMDKH/EU + ACMXADNH/EU Cooling Ø Ù ÚÛÜÝ ØÜÞÜßàÛáâ ãäø Ù ãåæçàèýå äåüû ØÜÞÜßàÛáâ éê Ù éúëåì êæþíû Heating îï ð îñòóô ïóõóö òøù úû ð úñüýþ ûÿõtò ²³ µ Capacities are based on following conditions; Refrigerant pipe length : m / Level difference : m.

37 MSP Duct A Units : mm [inches] Liquid pipe connection Gas pipe connection Drain pipe connection VP-(OD, ID) Power supply & Communication wiring conduit Air suction flange Air discharge flange 7 ±

38 . Dimensional Drawing MSP Duct AC9/MNMDKH/EU Units : mm [inches] Liquid pipe connection Gas pipe connection Drain pipe connection VP-(OD, ID) Power supply & Communication wiring conduit Air suction flange Air discharge flange 7 ±

39 MSP Duct AC/MNMDKH/EU Units : mm [inches] Liquid pipe connection Gas pipe connection Drain pipe connection VP-(OD, ID) Power supply & Communication wiring conduit Air suction flange Air discharge flange 7 ±

40 . Center of Gravity MSP Duct U C F 7 [7-9/] [] 9 [-7/] [-/] [9-/] [-/] 7 [7-9/] [-7/] [9-/] [-/] [9-/] [-/] 7 [7-9/] [-7/] [-/] [-/] [-/] [-/] ±

41 MSP Duct! "# Printed Circuit Board(MAIN) S-Plasma ion Thermistor ROOM OUT(K) Printed Circuit Board(BLDC DRIVER) Electronic Expansion Valve Thermistor EVA IN(K) Printed Circuit Board(SUB) EXTERNAL_CONTROL Thermistor EVA OUT(K) BLDC Motor ²³ µ This wiring diagram applies only to the Indoor unit. Symbols show as follow : blk: black, red: red, blu: blue, wht: white, yel: yellow, brn: brown, sky: skyblue: grn: green For connection wiring indoor-outdoor transmission F-F, indoor-wired remote controller transmission F-F. $%&' (%)%*+, &&%, - *%./( ±

42 7. Sound Data MSP Duct Sound Pressure level Discharge Duct m Suction Duct m Unit: db(a) M Microphone NR Curve ) ) 7 7 Sound Pressure Level (db) High Low NR NR NR NR NR NR NR NR NR NR NR Sound Pressure Level (db) High Low NR NR NR NR NR NR NR NR NR NR NR Octave Band Center Frequency(Hz) Octave Band Center Frequency(Hz) + ) 7 7 Sound Pressure Level (db) High Low NR NR NR NR NR NR NR NR NR NR NR Sound Pressure Level (db) High Low NR NR NR NR NR NR NR NR NR NR NR Octave Band Center Frequency(Hz) Octave Band Center Frequency(Hz) ±

43 MSP Duct Sound Pressure level Discharge Duct m Suction Duct m Microphone Unit: db(a) M 7 7 NR Curve ) ) Sound Pressure Level (db) 7 High Low NR NR NR NR NR NR NR NR NR NR NR Octave Band Center Frequency(Hz) Sound Pressure Level (db) 7 High Low NR NR NR NR NR NR NR NR NR NR NR Octave Band Center Frequency(Hz) 7+ ) Sound Pressure Level (db) 7 High Low NR NR NR NR NR NR NR NR NR NR NR Octave Band Center Frequency(Hz) Sound Pressure Level (db) 7 High Low NR NR NR NR NR NR NR NR NR NR NR Octave Band Center Frequency(Hz) ±

44 7. Sound Data MSP Duct Sound Power level ²³ µ Specifications may be subject to change without prior notice - Sound power level is an absolute value that a sound source generates. - dba = A-weighted sound power level. - Reference power : pw. - Measured according to ISO 7. Unit: db(a) M NR Curve ) ) Sound Power Level (db) NR NR NR NR NR NR NR NR NR NR NR A Sound Power Level (db) NR NR NR NR NR NR NR NR NR NR NR A Octave Band Center Frequency(Hz) Octave Band Center Frequency(Hz) + ) Sound Power Level (db) NR NR NR NR NR NR NR NR NR NR NR A Sound Power Level (db) NR NR NR NR NR NR NR NR NR NR NR A Octave Band Center Frequency(Hz) Octave Band Center Frequency(Hz) ±±

45 MSP Duct Sound Power level ²³ µ Specifications may be subject to change without prior notice - Sound power level is an absolute value that a sound source generates. - dba = A-weighted sound power level. - Reference power : pw. - Measured according to ISO 7. Unit: db(a) M NR Curve ) ) Sound Power Level (db) NR NR NR NR NR NR NR NR NR NR NR A Sound Power Level (db) NR NR NR NR NR NR NR NR NR NR NR A Octave Band Center Frequency(Hz) Octave Band Center Frequency(Hz) + ) Sound Power Level (db) NR NR NR NR NR NR NR NR NR NR NR A Sound Power Level (db) NR NR NR NR NR NR NR NR NR NR NR A Octave Band Center Frequency(Hz) Octave Band Center Frequency(Hz) ±

46 . Fan Characteristics MSP Duct ) ACMNMDKH/EU. B7C-C-7-7.< B7C-C Lower limit of Lower limit of <SP 7. B7C-CC <SP B7C-CD Lower limit of Lower limit of <SP. B7C-C9-7-7.<SP B7C-C Lower limit of Lower limit of ±

47 MSP Duct ) ACMNMDKH/EU P B7C-CF-7C-7 < SP B7C-C-7C Lower limit of Lower limit of < SP B7C-CED-7C-7 9< SP B7C-C9-7C Lower limit of Lower limit of < SP B7C-C9B-7C Lower limit of

48 . Fan Characteristics MSP Duct ) ACMNMDKH/EU P B7C-C-7C-7 < SP B7C-CAB-7C Lower limit of Lower limit of < SP B7C-CE-7C-7 9< SP B7C-C97-7C Lower limit of Lower limit of < SP B7C-C9C-7C Lower limit of

49 MSP Duct ) AC7MNMDKH/EU P B7C-C-77-7 < SP B7C-CAB Lower limit of Lower limit of < SP B7C-CE < SP B7C-C Lower limit of Lower limit of < SP B7C-C9C Lower limit of

50 . Fan Characteristics MSP Duct ) AC9MNMDKH/EU P B7C-C9F-7A-7 < SP B7C-C97-7A-7 Lower limit of Lower limit of < SP B7C-C99C-7A-7 < SP B7C-CAE-7A-7 Lower limit of Lower limit of

51 MSP Duct ) ACMNMDKH/EU P B7C-C9F-77-7 < SP B7C-C Lower limit of Lower limit of < SP B7C-C99C-77-7 < SP B7C-CAE-77-7 Lower limit of Lower limit of

52 . Fan Characteristics MSP Duct 7) ACMNMDKH/EU P B7C-C-77-7 < SP B7C-C Lower limit of Lower limit of < SP B7C-CFE-77-7 < SP B7C-C Lower limit of Lower limit of

53 MSP Duct ) ACMNMDKH/EU P B7C-C-7CA-7 < SP B7C-C9-7CA-7 Lower limit of Lower limit of < SP B7C-CFE-7CA-7 < SP B7C-C9-7CA-7 Lower limit of Lower limit of ²³ µ Adjust option code according to the actual installation condition ( ). The graphs display the available range of installed indoor units. Therefore, they do not reflect the actual change of and airflow rate according to adjusted airflow

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU SINGLE Technical Data Book Big Duct for EU (R4A, 0Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU History Version Modification Date Remark Ver 1.0 Release SINGLE Big Duct for EU (R4A, 0Hz, HP)

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book Wind-Free 4Way Cassette for North America (R4A, HP) Model : AM***NN4DCH/** History Version Modification Date Remark Ver.1. Released VRF Wind-Free 4Way Cassette for north America

More information

VRF. Technical Data Book. Slim duct for America (R410A, 60Hz, HP) Model : AM***FNLDCH***

VRF. Technical Data Book. Slim duct for America (R410A, 60Hz, HP) Model : AM***FNLDCH*** VRF Technical Data Book Slim duct for America (R41A, 6Hz, HP) Model : AM***FNLDCH*** History Version Modification Date Remark Ver.1. Release Slim duct for America (R41A, 6Hz, HP) 1.11.4 - Ver.1.1 1.12.28

More information

Slim duct (AMTTTFNLDEH ) Indoor units

Slim duct (AMTTTFNLDEH ) Indoor units Slim duct (AMTTTFNLDEH ) Slim duct. Specifications 1) Technical specifications Model AM22FNLDEH AM28FNLDEH AMFNLDEH AM4FNLDEH AMFNLDEH Power Supply Ø, #, V, Hz 1,2,22-24, 1,2,22-24, 1,2,22-24, 1,2,22-24,

More information

SINGLE. Technical Data Book. 4Way Cassette S for (Inv, R410A,

SINGLE. Technical Data Book. 4Way Cassette S for (Inv, R410A, SINGLE Technical Data Book 4Way Cassette S for (Inv, R410A, 1 Ver.1.0 Release Single 4Way Cassette S for USA (Inv, R410A, 60Hz, HP) TDB 15.02.05 - Ver.1. 5.0.09 Ver.1..0.0 Ver.1..0. Index 1 Nomenclature

More information

VRF. Technical Data Book. DVM S Eco 8, 9 HP

VRF. Technical Data Book. DVM S Eco 8, 9 HP VRF Technical Data Book DVM S Eco 8, 9 HP Version Modification Date Remark Ver.1.0 Released DVM S Eco 8,9HP TDB.06.26 Ver.1.1 Max pipe length modified(equivalent length) : 0 -> 130m 15.04.07 Nomenclature

More information

SINGLE. Technical Data Book. Multi-position AHU for North America (Low Ambient, R410A, 60Hz, H/P)

SINGLE. Technical Data Book. Multi-position AHU for North America (Low Ambient, R410A, 60Hz, H/P) SINGLE Technical Data Book for North America (Low Ambient, R410A, 60Hz, H/P) Model : AC030/036KNZDCH/AA (IDU) AC030/036JXSCCH/AA (ODU) History Version Modification Date Remark Ver.1.0 Release SINGLE TDB

More information

SINGLE. Technical Data Book. Multi-position AHU for North America (Low Ambient, R410A, 60Hz, H/P)

SINGLE. Technical Data Book. Multi-position AHU for North America (Low Ambient, R410A, 60Hz, H/P) SINGLE Technical Data Book for North America (Low Ambient, R410A, 60Hz, H/P) Model : AC030/036KNZDCH/AA (IDU) AC030/036JXSCCH/AA (ODU) History Version Modification Date Remark Ver.1.0 Release SINGLE TDB

More information

U-Match Series DC Inverter Service Manual PRODUCT

U-Match Series DC Inverter Service Manual PRODUCT PRODUCT 1 PRODUCT 1 MODELS LIST 1.1 Outdoor Unit Name Product Code Power Supply (V, Ph, Hz) Appearance GUHD24NS3GO CF090W0800 220-240V~ 50/60Hz GUHD36NS3GO CF090W0860 220-240V~ 50/60Hz GUHD42NS3GO CF090W0870

More information

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL E5-3I D-AP 4SP2U Slim Ducted type D-AP0074SP2U D-AP0094SP2U D-AP024SP2U D-AP054SP2U D-AP084SP2U Contents. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring diagram 6. Electrical

More information

DUCTED SPLIT SYSTEMS With Scroll compressors

DUCTED SPLIT SYSTEMS With Scroll compressors DUCTED SPLIT SYSTEMS With Scroll compressors 2 Benefits TOTAL COMFORT ON WIDE AREAS The Ducted Blower Split Systems for light commercial applications of DXDXT-M/K series are the ideal solution for keeping

More information

Air Conditioning Technical Data FVA-A > FVA71AMVEB > FVA100AMVEB > FVA125AMVEB > FVA140AMVEB

Air Conditioning Technical Data FVA-A > FVA71AMVEB > FVA100AMVEB > FVA125AMVEB > FVA140AMVEB Air Conditioning Technical Data FVA-A > FVA71AMVEB > FVA0AMVEB > FVA1AMVEB > FVA1AMVEB Indoor Unit FVA-A TABLE OF CONTENTS FVA-A 1 Features.............................................................

More information

Air Conditioning Technical Data FHA-A > FHA35AVEB > FHA50AVEB > FHA60AVEB > FHA71AVEB > FHA100AVEB > FHA125AVEB > FHA140AVEB

Air Conditioning Technical Data FHA-A > FHA35AVEB > FHA50AVEB > FHA60AVEB > FHA71AVEB > FHA100AVEB > FHA125AVEB > FHA140AVEB Air Conditioning Technical Data FHA-A > FHAAVEB > FHAAVEB > FHAAVEB > FHA71AVEB > FHA0AVEB > FHA1AVEB > FHA1AVEB TABLE OF CONTENTS FHA-A 1 Features.............................................................

More information

7. PCB AND FUNCTIONS

7. PCB AND FUNCTIONS Contents. PCB AND FUNCTIS. Outdoor Unit Control PCB... - -. Outdoor Unit Control PCB CR-C0DXH... - -. Outdoor Unit FAN PCB FAN-C00DXH... - -. Outdoor Unit FAN PCB FAN-C0DXH... - -. Outdoor Unit Filer PCB

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARYG72LHTA ARYG90LHTA OUTDOOR AOYG72LRLA AOYG90LRLA DR_AR012EF_03 2017.04.07 Notices: Product specifications and design are subject to change

More information

CTXA-AS/AT/AW, FTXA-AS/AT/AW

CTXA-AS/AT/AW, FTXA-AS/AT/AW Split Air Conditioning Technical Data CTXA-AS/AT/AW, FTXA-AS/AT/AW > CTXAA2V1BS > CTXAA2V1BT > CTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT > FTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT > FTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT

More information

Air Conditioning Technical Data FBA-A > FBA35A2VEB > FBA50A2VEB > FBA60A2VEB > FBA71A2VEB > FBA100A2VEB > FBA125A2VEB > FBA140A2VEB

Air Conditioning Technical Data FBA-A > FBA35A2VEB > FBA50A2VEB > FBA60A2VEB > FBA71A2VEB > FBA100A2VEB > FBA125A2VEB > FBA140A2VEB Air Conditioning Technical Data FBA-A > FBAA2VEB > FBAA2VEB > FBAA2VEB > FBA71A2VEB > FBA0A2VEB > FBA1A2VEB > FBA1A2VEB Indoor Unit FBA-A TABLE OF CONTENTS FBA-A 1 Features.............................................................

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXB-C

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXB-C Air Conditioning Technical Data Wall mounted unit EEDEN15-0 FTX-C Indoor Unit FTX-C TALE OF CONTENTS FTX-C 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning Technical Data FUA-A > FUA71AVEB > FUA100AVEB > FUA125AVEB

Air Conditioning Technical Data FUA-A > FUA71AVEB > FUA100AVEB > FUA125AVEB Air Conditioning Technical Data FUA-A > FUA71AVEB > FUA0AVEB > FUA125AVEB Indoor Unit FUA-A TABLE OF CONTENTS FUA-A 1 Features............................................................. 2 2 Specifications.......................................................

More information

MULTI SPLIT 074 PRODUCT LINEUP & 3-4 ROOMS MULTI ROOMS MULTI 080 INDOOR UNITS FOR MULTI SPLIT SPECIFICATIONS 082 MULTI COMBINATION

MULTI SPLIT 074 PRODUCT LINEUP & 3-4 ROOMS MULTI ROOMS MULTI 080 INDOOR UNITS FOR MULTI SPLIT SPECIFICATIONS 082 MULTI COMBINATION 072 MULTI SPLIT 074 PRODUCT LINEUP 076 2 & 3-4 ROOMS MULTI 078 5-6 ROOMS MULTI 080 INDOOR UNITS FOR MULTI SPLIT SPECIFICATIONS 082 MULTI COMBINATION TABLE 073 PRODUCT LINEUP MULTI SPLIT Outdoor Units FUJITSU

More information

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING

More information

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:

More information

R410A D2D_AU019E/

R410A D2D_AU019E/ R41A 2. : AUU18RCLX AUU24RCLX D2D_AU19E/ 27.6.11 2-1. FEATURE MODELS : AUU18RCLX / AOU18RLX AUU24RCLX / AOU24RLX FEATURES Easy maintenance The control box is easily accessible for maintenance work Wide

More information

VARIABLE REFRIGERANT FLOW SYSTEMS HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL

VARIABLE REFRIGERANT FLOW SYSTEMS HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL Expanding the possibilities STATE-OF-THE-ART DESIGN TAKES PERFORMANCE TO NEW LEVELS Our re-engineered Outdoor Units boast an extended operating

More information

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable

More information

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

Precision Cooling. Precision Cooling Advantages

Precision Cooling. Precision Cooling Advantages Precision Cooling Today s computing technologies compound conventional cooling problems. Blade servers, communications switches and other electronics are being packed into tighter and tighter spaces. Computing

More information

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

SPLIT lineup preview

SPLIT lineup preview Change things SPLIT - 2019 lineup preview DF19A021GB-00 The four Clivet families Feltre, 2019 SPLIT systems DF19A021GB-00-2 Light Commercial MULTI MONO STELVIO SCHIARA CRISTALLO ESSENTIAL 2 ODU-SM R-32

More information

SERVICE Manual DUCT TYPE AIR CONDITIONER. (Cool) OUTDOOR UNIT INDOOR UNIT TYPE UDH4400G DH44ZAX IDH4400A DH44ZA1(A2) ADH4400G DH44ZA1(A2)

SERVICE Manual DUCT TYPE AIR CONDITIONER. (Cool) OUTDOOR UNIT INDOOR UNIT TYPE UDH4400G DH44ZAX IDH4400A DH44ZA1(A2) ADH4400G DH44ZA1(A2) DUCT TYPE AIR CONDITIONER (Cool) TYPE ADH4400G DH44ZA(A2) INDOOR UNIT IDH4400A DH44ZA(A2) OUTDOOR UNIT UDH4400G DH44ZAX SERVICE Manual AIR CONDITIONER CONTENTS. Product Specifications 2. Installation 3.

More information

Product Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound 24VNA9 Infinityr 19VS Variable Air Conditioner with Puronr Refrigerant 2 --- 5 Ton Product Data The Infinity 19VS air conditioner offers high -efficiency variable speed performance in a remarkably small

More information

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS Circular ceiling air diffuser for supply air QUICK FACTS Ceiling air diffuser for supply air in rooms with high ceiling Manual operated change of spread direction as standard Motor operated change of spread

More information

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS Now Only One Unit Required for Initial Start-up Multi Zone Inverter Heat Pump High Efficiency Multi 21+ heat pump units can heat and cool up to 5 zones without

More information

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote

More information

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough

More information

DAIKIN GAS TIGHT JOINT (DGT)

DAIKIN GAS TIGHT JOINT (DGT) LINE UP Model Name Size (mm) DAIKIN GAS TIGHT JOINT (DGT) SPECIFICATIONS BDGTA06 ø 6.4 BDGTA06 ø 9.5 BDGTA12 ø 12.7 BDGTA15 ø 15.9 BDGTA19 ø 19.1 BDGTA22 ø 22.2 BDGTA28 ø 28.6 DAIKIN GAS TIGHT JOINT Applicable

More information

HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER

HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER HVH8 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUP WITH OBSERVER COUNICATING CONTROL SYSTE 2 THRU 5 TONS SPLIT SYSTE 208 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Variable

More information

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal

More information

FPS SERIES Super Slim Ceiling Mount Air Handling Units

FPS SERIES Super Slim Ceiling Mount Air Handling Units About Multistack 19, Multistack is well-known in the international air conditioning industry by its invention of modular chiller. Today, Multistack has grown into an international refrigeration & air conditioning

More information

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers TM PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers WE ARE VERTIV Vertiv, formerly Emerson Network Power, designs, builds, and services mission critical technologies that

More information

PLXRMM1605. Wall Mounted. FT-A Series. COOLING ONLY [50Hz] V

PLXRMM1605. Wall Mounted. FT-A Series. COOLING ONLY [50Hz] V PLXRMM1605 Wall Mounted FT-A Series COOLING ONLY [50Hz] 220-240V COMFORT 1 Daikin s FT-A series A simple, stylish and sleek wall mounted air conditioner that blends into any environment, providing the

More information

Kirby NK Heavy Commercial Industrial Unit Cooler. Natural fluids: Glycol water

Kirby NK Heavy Commercial Industrial Unit Cooler. Natural fluids: Glycol water Kirby NK Heavy Commercial Industrial Unit Cooler Natural fluids: Glycol water MT 20kW LT 16kW 110kW 68kW Product Overview > The NK range is designed for industrial refrigeration, storage or deep-freezing

More information

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA 99 glide air cooled liquid chillers ND free cooling chillers glider 178 1328 Energy Class More efficient + B C D E F G Less efficient R134a CLSS SHELL C E C FREE COOLING 100 air cooled liquid chiller and

More information

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how

More information

Adjustable swirl diffuser PDZA TECHNICAL DATA

Adjustable swirl diffuser PDZA TECHNICAL DATA Adjustable swirl diffuser PDZA TECHNICAL DATA Adjustable swirl diffuser PDZA Adjustable ceiling swirl diffuser PDZA is intended for commercial and industrial buildings with a large room volume and high

More information

A NEW GENERATION OF AIR-CONDITIONING SYSTEMS FOR BOATS AND YACHTS TECHNICAL SPECIFICATIONS CLION-MARINE AIR-CONDITIONING

A NEW GENERATION OF AIR-CONDITIONING SYSTEMS FOR BOATS AND YACHTS TECHNICAL SPECIFICATIONS CLION-MARINE AIR-CONDITIONING A NEW GENERATION OF AIR-CONDITIONING SYSTEMS FOR BOATS AND YACHTS TECHNICAL SPECIFICATIONS CLION-MARINE AIR-CONDITIONING TECHNICAL SPECIFICATIONS CLION-MARINE AIR-CONDITIONING Index Specifications Chiller

More information

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,

More information

Blue e+ chillers with the principle

Blue e+ chillers with the principle Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide

More information

GP SERIES Packaged Chillers

GP SERIES Packaged Chillers Blending Conveying Drying Process Cooling Heat Transfer Size Reduction GP SERIES Packaged Chillers Comprehensive Flexible Versatile Compact unitary designs available in a variety of configurations from

More information

FEATURES AND BENEFITS. Installation and operation. Controller

FEATURES AND BENEFITS. Installation and operation. Controller DFC 350 & 450 DISPLACEMENT FREE COOLING Function The Dantherm Displacement Free Cooling (DFC) unit is a slim, passive cooling solution designed to remove excess heat from rooms with sensitive equipment.

More information

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners DCC Commercial Submittal Data Form 15-25 Tons Packaged Air Conditioners 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h Job Name

More information

Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA

Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA Nozzle diffuser DYVZ / Supply air unit DYVB (DYVZ+ATVA) DYVZ DYVB (DYVZ + ATVA) The DYVB is a quiet wall mounted supply air unit that consists

More information

E4PA. Ultrasonic Displacement Sensor. Ordering Information

E4PA. Ultrasonic Displacement Sensor. Ordering Information Ultrasonic Displacement Sensor Ideal for controlling liquid level. Long sensing distance and high-resolution analog output. High-precision detection with a wide range of measurements Four types of Sensors

More information

6. Performance Air velocity distribution (Cassette Type) 18K BTU PERFORMANCE CONDITION SAMSUNG 101. Fan speed : High Operation mode : Blowing

6. Performance Air velocity distribution (Cassette Type) 18K BTU PERFORMANCE CONDITION SAMSUNG 101. Fan speed : High Operation mode : Blowing 6 Performance 6-1. Air velocity distribution (Cassette Type) 6-2. The distribution of temperature each space section 6-3. The Graph of Air-flow (Cassette Type) 6-4. Graph of Air-flow rate vs external static

More information

ALFRESCO SERIES RESIDENTIAL WEATHER RATED TV ENCLOSURES PRODUCT OVERVIEW. Specifications and Detailed Product Overview

ALFRESCO SERIES RESIDENTIAL WEATHER RATED TV ENCLOSURES PRODUCT OVERVIEW. Specifications and Detailed Product Overview RESIDENTIAL WEATHER RATED TV ENCLOSURES PRODUCT OVERVIEW Specifications and Detailed Product Overview WEATHER RATED TV ENCLOSURES Designed and engineered in Australia, to suit our tough environmental conditions,

More information

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN IntesisBox HS-RC-MBS-1 v.0.1 Modbus RTU (EIA-485) Interface for Hisense air conditioners. Compatible with commercial line of air conditioners commercialized by Hisense. User Manual Issue Date: 12/2017

More information

Product Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) Product Data the environmentally sound refrigerant Carrier s Air Conditioners with Puronr refrigerant provide

More information

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS RAH 913 K AIR R-407C R-134a Series RAH... from 307 to 1879 kw - from 1 to 4 circuits The air cooled chillers of RAH series are extremely compact units so to reduce the installation spaces and weights.

More information

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24, ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) SXT+ Product Specifications HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208

More information

Ceiling Concealed Split System C Series

Ceiling Concealed Split System C Series Brochure AP MCC C 07A Ceiling Concealed Split System C Series features: Microprocessor Controlled ith the microprocessor controlling the operation, the MCC model can offer comfortable room conditions according

More information

kyalfa V- VDD/VDD6 General Contents

kyalfa V- VDD/VDD6 General Contents General Contents. kyalfa V- VDD/VDD6 ky General Contents General Features A dry cooler is a forced convection air-cooled fluid cooler, designed for outdoor installation. Air is forced over the finned coil

More information

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS C35 PRODUCT SPECIFICATIONS Upflow - Cased and Uncased Bulletin No. 20666 February 208 Supersedes November 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION Unit Type C = Indoor Coil = Upflow Series

More information

VIREO Ceiling with ALX

VIREO Ceiling with ALX Square ceiling air diffuser with nozzles for supply air, with plenum box QUICK FACTS Flush design Suitable for VAV-applications Fast and easy installation Sealing ring, standard for spigot Energy efficient

More information

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo UPGRADE PROGRAM V250 Series Pumps vs V301 Series Pumps Technical Memo INDEX Outline drawings ISO100 3 Outline Drawing CFF6 5 Technical Specification 7 Notes 8 Accessories 8 Controller comparison 9 Outline

More information

TECHNICAL DATA SHEET DS 16S/DS 16SE. FreeSpace. Loudspeakers. Product Overview. Key Features. Product Information. Applications

TECHNICAL DATA SHEET DS 16S/DS 16SE. FreeSpace. Loudspeakers. Product Overview. Key Features. Product Information. Applications Product Overview Bose FreeSpace DS 16S and FreeSpace DS 16SE loudspeakers are high-performance, surfacemount loudspeakers designed for background music and speech reproduction in a wide range of commercial

More information

Assembly and Maintenance

Assembly and Maintenance Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines

More information

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT H4A4 DX 1400 Product Specifications HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1-phase, 60 Hz

More information

User's manual. GREE AHU kit. Type: U-Match Version: 1.02

User's manual. GREE AHU kit. Type: U-Match Version: 1.02 User's manual GREE AHU kit Type: U-Match Version: 1.02 Thank you for choosing AHU com, please read this user's manual carefully before operation and keep it for further reference. If you have lost the

More information

Product Data. S Up to 19 SEER /13.0 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 19 SEER /13.0 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound 25VNA8 Infinityr 18VS Variable Heat Pump with Puronr Refrigerant Product Data The Infinity 18VS heat pump offers high -efficiency variable speed performance in a remarkably small cabinet and provides up

More information

Product Data. S Up to 18 SEER /12.5 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 18 SEER /12.5 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound 25VNA8 Infinityr 18VS Variable Heat Pump with Puronr Refrigerant 2 --- 5 Ton Product Data The Infinity 18VS heat pump offers high -efficiency variable speed performance in a remarkably small cabinet and

More information

Product Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) the environmentally sound refrigerant Carrier s heat pumps with Puronr refrigerant provide a collection of features

More information

Product Data. S Up to 19 SEER /13 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 19 SEER /13 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound 288BNV EVOLUTION R V VARIABLE SPEED HEAT PUMP WITH PURONr REFRIGERANT 2, 3, 4 AND 5-TON Product Data The Evolutionr V heat pump offers high -efficiency variable speed performance in a remarkably small

More information

Grundfos ALPHA2. Performance. It always pays to read the label. H [m] Q [m 3 /h] ALPHA2 Technical data

Grundfos ALPHA2. Performance. It always pays to read the label. H [m] Q [m 3 /h] ALPHA2 Technical data GRUNDFOS ALPA Grundfos ALPA Grundfos is proud to present the next generation of energy-efficient circulators the ALPA. The ALPA is a great revolution in a small package. Rated A for its energy efficiency,

More information

IntesisBox DK-RC-MBS-1 v.0.2

IntesisBox DK-RC-MBS-1 v.0.2 IntesisBox DK-RC-MBS-1 v.0.2 MODBUS RTU (RS-485) Interface for Daikin air conditioners. Compatible with VRV and SKY line air conditioners commercialized by Daikin. User Manual Issue Date: 2011/05/05 Order

More information

Jaga-Deco Pro thermostatic valves

Jaga-Deco Pro thermostatic valves Valves Range Jaga-Deco manual valves Jaga-Deco Pro thermostatic valves Jaga-Deco thermostatic valves for single point connection - manual chrome-plated valve for connection to the wall or to the floor

More information

ECON-ZIP-BASE. ZIP Economizer Base Module

ECON-ZIP-BASE. ZIP Economizer Base Module ECON-ZIP-BASE ZIP Economizer Base Module You can mount the ZIP Economizer in any orientation; it is recommended that you mount it in a position that will allow full utilization of the LCD and key pad and

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data SS-PRC014-EN Split System Cooling Product & Performance Data 2TTA0030-072A 2½ 6 Tons PUB. NO. 22-1740-01-0702 (EN) General Features Split System Cooling Units... The Evolution Continues 2TTA0 split systems

More information

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS CX35 Upflow - Cased - R-40A PRODUCT SPECIFICATIONS Bulletin No. 0668 November 06 Supersedes September 05.5 to 5 Tons MODEL NUMBER IDENTIFICATION C X 35-36 A - 6 F Unit Type C = Indoor Coil

More information

IntesisBox DK-RC-MBS-1 v.0.8

IntesisBox DK-RC-MBS-1 v.0.8 IntesisBox DK-RC-MBS-1 v.0.8 MODBUS RTU (RS-485) Interface for Daikin air conditioners. Compatible with VRV and SKY line air conditioners commercialized by Daikin. User Manual Issue Date: 2013/02/26 Order

More information

Precision Cooling Mission Critical Air Handling Units

Precision Cooling Mission Critical Air Handling Units M I S S I O N C R I T I CA L C O O L I N G Precision Cooling Mission Critical Air Handling Units Global Expertise for Precision Cooling Solutions STULZ is a privately owned, global manufacturer of highly

More information

Modbus Register Map: InRow ACRD60x / ACRC60x

Modbus Register Map: InRow ACRD60x / ACRC60x Modbus Map: InRow ACRD60x / ACRC60x Notes: 1. 16-bit registers (INT16, UINT16, ENUM) are transmitted MSB first (i.e., big-endian). 2. INT32 and UINT32 are most-significant word in n+0, least significant

More information

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function. Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Application Examples Detecting slackness in sheet materials Detecting liquid levels Remotely detecting

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data SS-PRC009-EN Split System Cooling Product & Performance Data 2TTA2030-060A 2½ 5 Tons PUB. NO. 22-1735-01-0302 (EN) General Features Split System Cooling Units... The Evolution Continues 2TTA2 split systems

More information

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons Series Multi-Position, Internal TXV Multi-Speed ECM Based Air Handler ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions... Airflow Data...6 Heat Kit Data... Wiring

More information

Series P215DP Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Series P215DP Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter) PSC 0108 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression

More information

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens

More information

Register Map: Ecoflair Indirect Air Economizer

Register Map: Ecoflair Indirect Air Economizer Register Map: Ecoflair Indirect Air Economizer Notes: 1. 16-bit registers (INT16, UINT16, ENUM) are transmitted MSB first (i.e., big-endian). 2. INT32 and UINT32 are most-significant word in n+0, least

More information

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 0 Jl. Malibu Raya, Cengkareng Jakarta Barat 70 Indonesia Phone + 4 4 www.climanusa.com Marketing features prominent presence on the world

More information

Specification and Design Catalog. Waterside Economizer

Specification and Design Catalog. Waterside Economizer Specification and Design Catalog Waterside Economizer Table of Contents Waterside Economizer Applications.................................................... 4 Application Notes..................................................................

More information

Pressure switch KP. Data sheet

Pressure switch KP. Data sheet Data sheet Pressure switch KP KP switchs are for use in refrigeration and air conditioning systems to give protection against excessively low suction or excessively high discharge. KP switches are also

More information

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server Data Sheet FUJITSU Server Scale out Server Data Sheet FUJITSU Server Scale out Server Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing FUJITSU Server PRIMERGY will give you the servers you

More information

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,

More information

Table of Contents. Safety. Attention. Warnings

Table of Contents. Safety. Attention. Warnings Solstart Miniature Soft Starter 8-58A, 220-600V Instruction Manual Ver. 21.2. 2002 Table of Contents Page Subject 3 Starter Selection 4 Installation Notes 5 Wiring 6 Starter Settings & Start-up Procedure

More information

Reliability and extended operation

Reliability and extended operation CLIMAVENETA TELECOMSOLUTIONS Units for mobile telecounication applications, with free cooling and full DC Inverter technology. 1,5 20. Low operational and maintenance costs Wide range of full inverter

More information

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. Data sheet Thermostat KP The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kw or

More information

Product Data. SYSTXCCUIZ01-- B Infinityt Zone Control. INFINITY t ZONE CONTROL

Product Data. SYSTXCCUIZ01-- B Infinityt Zone Control. INFINITY t ZONE CONTROL SYSTXCCUIZ01-- B Infinityt Zone Control Product Data A07258 NOTE: Infinity Zone Control compatible with Infinity rated indoor equipment only. INFINITY t ZONE CONTROL Carrier specializes in creating a customized

More information

Semi-hermetic Air-cooled Condensing Units

Semi-hermetic Air-cooled Condensing Units Semi-hermetic Air-cooled Condensing Units For Indoor and Outdoor Applications DFA-002-1 R22 R404A R507 R22 DFA Indoor Model Standard Features Bitzer OCTAGON series compressors up to 7 ½ HP. Dual adjustable

More information

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request PRODUCT DATA & SPECIFICATIONS Bulletin B40-BC-PDS Part # 1106712 PRODUCT SUPPORT web: b-rp.ca/bc email: multicompcu@b-rp.ca call: 1-844-893-3222 x524 scan: BC Combination Condensing Units Cooler/Freezer

More information

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps VARIAN vacuum technologies UPGRADE PROGRAM V70 Series Pumps vs V81T Series Pumps Technical Memo Technical Memo - 1 - V70 series vs V81-T INDEX Outline drawings ISO63 3 Outline drawings CF2-¾ 4 Outline

More information