VNA Tools II in the lab practical aspects

Size: px
Start display at page:

Download "VNA Tools II in the lab practical aspects"

Transcription

1 Federal Department of Justice and Police FDJP Federal Office of Metrology METAS VNA Tools II in the lab practical aspects European Metrology workshop (inrim, Torino) Juerg Ruefenacht Michael Wollensack May 2011

2 VNA Tools II topics The graphical user interface (GUI) The multistep measurement process Project examples VNA Data Explorer (data visualisation only) METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 2

3 The graphical user interface (GUI) live demo METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 3

4 Multistep measurement process The multistep measurement process Basic influence parameters with uncertainties S-parameter data with uncertainties METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 4

5 Specify: instrument settings (VNA hardware) METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 5

6 Collect: settings, actions and measurement data Measurement Journal (time stamps log file of the complete measurement process) METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 6

7 Define: type of calibration (1/3) Calibration Config (first action: new calibration configuration) Calibration types: OnePort SOLT GSOLT QSOLT UnkwnownThru TRL Optimization METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 7

8 Assign: measurement data standard definitions (2/3) Calibration Config METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 8

9 Calculate: Error Terms (3/3) Calibration Config METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 9

10 Correct: the raw measurement data Error Correction (Error correction of all data located in the raw measurements path) METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 10

11 Visualisation / Comparison / Data Analysis (1/3) METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 11

12 Visualisation / Comparison / Data Analysis (2/3) METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 12

13 Visualisation / Comparison / Data Analysis (3/3) METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 13

14 VNA Tools II project examples 1-Port Calibration 2-Port Calibration (SOLT vs Unknown Thru) 3-Port Calibration (if time is left) live demo METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 14

15 VNA Data Explorer METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 15

16 Conclusions VNA expert application including uncertainty propagation High flexibility - Expert Tool Allows to directly compare different types of calibration Powerful visualisation for data analysis Data processing tools (including uncertainty data) (Math / cascade / merge / mean / circle fit / interpolate ) METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 16

17 Federal Department of Justice and Police FDJP Federal Office of Metrology METAS Thank you very much for your attention! METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 17

18 METAS Juerg Ruefenacht + Michael Wollensack European Metrology workshop, Torino May 2011 slide 18

Practical hints: splitter characterization. J. Ruefenacht, M. Wollensack, J. Hoffmann, M. Zeier

Practical hints: splitter characterization. J. Ruefenacht, M. Wollensack, J. Hoffmann, M. Zeier Practical hints: splitter characterization J. Ruefenacht, M. Wollensack, J. Hoffmann, M. Zeier Motivation once upon a time at METAS Juerg Ruefenacht HF-Circuits, European ANAMET Meeting, METAS 03.06.2015

More information

Pin diameter specifications and challenges

Pin diameter specifications and challenges Federal Department of Justice and Police FDJP Federal Office of Metrology METAS Pin diameter specifications and challenges 32nd ANAMET meeting (NPL, Teddington) Juerg Ruefenacht 16 October 2009 Pin diameter

More information

Calibration kit coefficients -the saga continues

Calibration kit coefficients -the saga continues Calibration kit coefficients -the saga continues 22nd ANAMET Meeting 9 th September 2004 Jürg Rüfenacht Swiss Federal Office of Metrology and Accreditation metas Lindenweg 50, CH-3003 Bern-Wabern, Switzerland

More information

Adapter characterization up to 110 GHz

Adapter characterization up to 110 GHz Adapter characterization up to 110 GHz EMRP HF Circuits project: 6 th European ANAMET meeting 28.06.2016 Adapter characterization: Motivation The challenges of an adapter characterization: Sheet Series

More information

Application of second-tier VNA calibration. MTT/IMS May 2010

Application of second-tier VNA calibration. MTT/IMS May 2010 Application of second-tier VNA calibration with Cascade Microtech WinCal XE Craig CagKirkpatrick MTT/IMS May 2010 What is Two Tier Calibration? Two Tier Calibration of a Vector Network Analyzer is a technique

More information

TN Vector Network Analyzer Calibrations and Their Effect on Measurement Results. Bernie McDermott. May 2010

TN Vector Network Analyzer Calibrations and Their Effect on Measurement Results. Bernie McDermott. May 2010 TN 201005 Vector Network Analyzer Calibrations and Their Effect on Measurement Results May 2010 Bernie McDermott Lead Metrologist Calibration Products and Services Measurement Examples and Technical Notes

More information

Lecture 10. Vector Network Analyzers and Signal Flow Graphs

Lecture 10. Vector Network Analyzers and Signal Flow Graphs HP8510 Lecture 10 Vector Network Analyzers and Signal Flow Graphs Sections: 6.7 and 6.11 Homework: From Section 6.13 Exercises: 4, 5, 6, 7, 9, 10, 22 Acknowledgement: Some diagrams and photos are from

More information

An assessment of a VNA electronic calibrator

An assessment of a VNA electronic calibrator An assessment of a VNA electronic calibrator Presentation by Christopher Eiø Præsentation: ANAMET, NPL, torsdag 3. marts Background The concept of electronic calibrators has been around for a number of

More information

Application Note FOR SMA Calibration Kit for VNA. LCAL06A A female calibration kit and used for DC ~ 6.0 GHz VNA test cable with male end connector.

Application Note FOR SMA Calibration Kit for VNA. LCAL06A A female calibration kit and used for DC ~ 6.0 GHz VNA test cable with male end connector. Application Note FOR SMA Calibration Kit for VNA LCAL06A, LCAL06B, LCAL06C and LCAL09A are precision SMA calibration kits which provide accurate and reliable Short-Open-Load-Thru (SOLT) or Load-Reflect-Match

More information

3.5mm VNA Calibration Kits

3.5mm VNA Calibration Kits 3.5mm VNA Calibration Kits DATA SHEET / 2Z-059 Models: 8050CK10 Fixed Load Kit 8050CK11 Fixed Load Kit Plus Adapters 8050CK20 Sliding Load Kit - Basic 8050CK21 Sliding Load Kit Plus Adapters 8050CK30 TRL

More information

2.92mm VNA Calibration Kits

2.92mm VNA Calibration Kits 2.92mm VNA Calibration Kits DATA SHEET / 2Z-058B Models: 8770CK10 Fixed Load Kit 8770CK11 Fixed Load Kit Plus Adapters 8770CK20 Sliding Load Kit 8770CK21 Sliding Load Kit Plus Adapters 8770CK30 TRL Kit

More information

What We Do. Fixturing and Fixture Removal for Multiport Devices with Non-Standard RF Interfaces. Fully automate for: Speed, Accuracy, Ease of Use

What We Do. Fixturing and Fixture Removal for Multiport Devices with Non-Standard RF Interfaces. Fully automate for: Speed, Accuracy, Ease of Use Fixturing and Fixture Removal for Multiport Devices with Non-Standard RF Interfaces What We Do Fully automate for: Speed, Accuracy, Ease of Use Calibration Validation To give confidence in test results

More information

TNC VNA Calibration Kits

TNC VNA Calibration Kits TNC VNA Calibration Kits DATA SHEET / 2Z-062 Models: 8650CK10 Fixed Load Kit 8650CK11 Fixed Load Kit Plus Adapters 8650CK20 Sliding Load Kit 8650CK21 Sliding Load Kit Plus Adapters // JANUARY 2018 TNC

More information

Measurement Accuracy of Vector Network Analysis. Thilo Bednorz

Measurement Accuracy of Vector Network Analysis. Thilo Bednorz Measurement Accuracy of Vector Network Analysis Thilo Bednorz EDICON 2019 VNA Measurement and Accuracy Error sources occuring with VNA measurement measurement errors stochastic errors systematic errors

More information

Improved RSOL Planar Calibration via EM Modelling and Reduced Spread Resistive Layers

Improved RSOL Planar Calibration via EM Modelling and Reduced Spread Resistive Layers Improved RSOL Planar Calibration via EM Modelling and Reduced Spread Resistive Layers M. Spirito 1, L. Galatro 1, G. Lorito 2, T. Zoumpoulidis 2, F. Mubarak 1,3 1 Delft University of Technology, Electronic

More information

White Paper. Abstract

White Paper. Abstract Keysight Technologies Sensitivity Analysis of One-port Characterized Devices in Vector Network Analyzer Calibrations: Theory and Computational Analysis White Paper Abstract In this paper we present the

More information

laboratories and production environments.

laboratories and production environments. Improved, user-friendly RF&MW calibration techniques for calibration laboratories and production environments. Reducing calibration time & uncertainties by using known, characterized standards. Harald

More information

DEMO OF ISO/IEC 17025:2017 AWARENESS AND AUDITOR TRAINING PPT PRESENTATION KIT

DEMO OF ISO/IEC 17025:2017 AWARENESS AND AUDITOR TRAINING PPT PRESENTATION KIT DEMO OF ISO/IEC 17025:2017 AWARENESS AND AUDITOR TRAINING PPT PRESENTATION KIT CONTENTS OF ISO/IEC 17025:2017 AWARENESS AND AUDITOR TRAINING PPT PRESENTATIONS TRAINING KIT ISO/IEC 17025:2017 Awareness

More information

IEEE 802 Plenary Session July 14-19, 2012 Geneva, Switzerland

IEEE 802 Plenary Session July 14-19, 2012 Geneva, Switzerland IEEE 802 Plenary Session July 14-19, 2012 Geneva, Switzerland AAA 2 C Automotive Requirements for a Flexible Control Traffic Class & Development 1 AAA 2 C 2 AAA 2 C: AVnu sponsored Automotive AVB Gen 2

More information

DEVNET Introduction to Git. Ashley Roach Principal Engineer Evangelist

DEVNET Introduction to Git. Ashley Roach Principal Engineer Evangelist DEVNET-1080 Introduction to Git Ashley Roach Principal Engineer Evangelist Twitter: @aroach Email: asroach@cisco.com Cisco Spark How Questions? Use Cisco Spark to communicate with the speaker after the

More information

Optical Testing... What s involved, and how it s done. Hugh Barton, OptiConsulting

Optical Testing... What s involved, and how it s done. Hugh Barton, OptiConsulting Optical Testing... What s involved, and how it s done. Slide 1 Why do we Test? Demonstrate compliance (or otherwise) with specifications CE Marking Manage risk Develop confidence during the design / development

More information

Deembedding of SiGe multifinger HBTs to. 110 GHz - problems and solutions. Lab. RF Modeling

Deembedding of SiGe multifinger HBTs to. 110 GHz - problems and solutions. Lab. RF Modeling Deembedding of SiGe multifinger HBTs to 110 GHz - problems and solutions 1 overview - measurement setup - ISS vs on wafer calibration - open - short deembedding - results small transistor - ISS to on wafer

More information

Copyright ANRITSU. All rights reserved.

Copyright ANRITSU. All rights reserved. General Caution --------------- Please use a USB Memory Stick for firmware updates. If there is a firmware update question, please contact Anritsu service support at https://techsupport.anritsu.com, and

More information

Barcode Magician Application Note

Barcode Magician Application Note ON TIME SUPPORT, INC. BCM-APPNOTE-20120201 Page 1 Barcode Magician Application Note Using Barcode Magician@ Plus to make Mass Updates to the Fluke@ Met/Track@ Database Barcode Magician (BCM) has been a

More information

Agilent Technologies S-Parameter and TDR Impedance Measurement Solution Summary

Agilent Technologies S-Parameter and TDR Impedance Measurement Solution Summary Agilent Technologies S-Parameter and TDR Impedance Measurement Solution Summary Built-in S-parameter testing Easy and accurate transmission channel/media characterization Transmission lines for high speed

More information

Copyright ANRITSU. All rights reserved.

Copyright ANRITSU. All rights reserved. ShockLine VNA Software If there is a software/firmware update question, please contact Anritsu service support at https://techsupport.anritsu.com, and then click on "Technical Support" for further information.

More information

ISO INTERNATIONAL STANDARD. Test code for machine tools Part 4: Circular tests for numerically controlled machine tools

ISO INTERNATIONAL STANDARD. Test code for machine tools Part 4: Circular tests for numerically controlled machine tools INTERNATIONAL STANDARD ISO 230-4 Second edition 2005-04-01 Test code for machine tools Part 4: Circular tests for numerically controlled machine tools Code d'essai des machines-outils Partie 4: Essais

More information

ClearSpeed Visual Profiler

ClearSpeed Visual Profiler ClearSpeed Visual Profiler Copyright 2007 ClearSpeed Technology plc. All rights reserved. 12 November 2007 www.clearspeed.com 1 Profiling Application Code Why use a profiler? Program analysis tools are

More information

Keysight Technologies Specifying Calibration Standards and Kits for Keysight Vector Network Analyzers. Application Note

Keysight Technologies Specifying Calibration Standards and Kits for Keysight Vector Network Analyzers. Application Note Keysight Technologies Speciying Calibration Standards and Kits or Keysight Vector Network Analyzers Application Note Introduction Measurement errors in network analysis can be separated into two categories:

More information

A simple method to characterize and accurately remove the effects of push-on connectors. O.J. Danzy Application Engineer

A simple method to characterize and accurately remove the effects of push-on connectors. O.J. Danzy Application Engineer A simple method to characterize and accurately remove the effects of push-on connectors. O.J. Danzy Application Engineer Original Authors Robert Schaefer, Keysight Technologies, Inc. Reiner Oppelt, Rosenberger

More information

Calibration Service - Flowmeters

Calibration Service - Flowmeters Products Solutions Services Calibration Service - Flowmeters COMING SOON!!! Cost-effective, reliable calibration as and when needed Slide 1 Calibration and Verification The verification and calibration

More information

A standard for list-mode data Advantages in nuclear security

A standard for list-mode data Advantages in nuclear security The European Commission s science and knowledge service Joint Research Centre A standard for list-mode data Advantages in nuclear security MAGIC MAGGIORE - JRC/GICNT Technical Reachback Workshop 28-30

More information

Integrating Data Acquisition and Instrument Control with Your Scilab Scripts

Integrating Data Acquisition and Instrument Control with Your Scilab Scripts Integrating Data Acquisition and Instrument Control with Your Scilab Scripts Darcy Dement Marketing Director National Instruments France darcy.dement@ni.com Who We Are 800 Leaders in Computer-based Measurement

More information

Gavin Fisher Cascade Microtech Europe

Gavin Fisher Cascade Microtech Europe Gavin Fisher Cascade Microtech Europe Device measurement at it s simplest requires the following steps Probe and accessory physical Set-up for calibration Calibration instrumentation setting preparation

More information

Plant Modeling for Powertrain Control Design

Plant Modeling for Powertrain Control Design Plant Modeling for Powertrain Control Design Modelica Automotive Workshop Dearborn, MI November 19, 2002 Dr. Larry Michaels GM Powertrain Controls Engineering Challenges in PT Control Design Control System

More information

MILLIMETER WAVE CALIBRATION KIT BROCHURE

MILLIMETER WAVE CALIBRATION KIT BROCHURE MILLIMETER WAVE CALIBRATION KIT BROCHURE - 1 - General Information OML s millimeter wave calibration kits contain the waveguide components that accurately calibrate your vector network analyzer for precision

More information

PocketVNA API documentation

PocketVNA API documentation PocketVNA API documentation Brief Info Package Content Examples and bindings Linux Specific Using API Workflow Function Descriptions Driver routines: Connection Management: Device work: Debug purposes:

More information

Appendix U. Development towards 3D thermography. Gianluca Casarosa (ESA/ESTEC, The Netherlands)

Appendix U. Development towards 3D thermography. Gianluca Casarosa (ESA/ESTEC, The Netherlands) 277 Appendix U Development towards 3D thermography Gianluca Casarosa (ESA/ESTEC, The Netherlands) 278 Development towards 3D thermography Abstract The presentation reports on an activity aimed at solving

More information

Synthesis & Prototyping

Synthesis & Prototyping UMBRELLA Workshop on System State Modelling and Toolbox Design, 23 rd of October 2014, Brussels 1 Workshop on System State Modelling and Toolbox Design Synthesis & Prototyping 23rd of October 2014, Brussels

More information

HP 8714B Calibration

HP 8714B Calibration Wireless Circuits and Systems Laboratory Procedure #7 Calibrating the HP 8714 Network Analyzer This procedure describes the different types of calibrations that are available with the HP 8714 vector network

More information

AEMLog Users Guide. Version 1.01

AEMLog Users Guide. Version 1.01 AEMLog Users Guide Version 1.01 INTRODUCTION...2 DOCUMENTATION...2 INSTALLING AEMLOG...4 AEMLOG QUICK REFERENCE...5 THE MAIN GRAPH SCREEN...5 MENU COMMANDS...6 File Menu...6 Graph Menu...7 Analysis Menu...8

More information

The compiled VNAView application for Macintosh requires: The NI-VISA driver. LabVIEW 2014 runtime engine. VNAView application.

The compiled VNAView application for Macintosh requires: The NI-VISA driver. LabVIEW 2014 runtime engine. VNAView application. VNAView for Macintosh Installing and Getting Started Rev. Jan 19, 2016 for VNAView R5.5 or later Gary Johnson, NA6O gwj@wb9jps.com The compiled VNAView application for Macintosh requires: The NI-VISA driver.

More information

Certification Exam Preparation Seminar: Oracle Database SQL

Certification Exam Preparation Seminar: Oracle Database SQL Oracle University Contact Us: 0800 891 6502 Certification Exam Preparation Seminar: Oracle Database SQL Duration: 1 Day What you will learn This video seminar Certification Exam Preparation Seminar: Oracle

More information

Design optimization and design exploration using an open source framework on HPC facilities Presented by: Joel GUERRERO

Design optimization and design exploration using an open source framework on HPC facilities Presented by: Joel GUERRERO Workshop HPC Methods for Engineering CINECA (Milan, Italy). June 17th-19th, 2015. Design optimization and design exploration using an open source framework on HPC facilities Presented by: Joel GUERRERO

More information

The MCS shade evaluation procedure. Part 2 How to record shade onto the chart

The MCS shade evaluation procedure. Part 2 How to record shade onto the chart The MCS shade evaluation procedure Part 2 How to record shade onto the chart The MCS shade evaluation procedure Part 1 The procedure explained (previous presentation) Part 2 How to record shade onto the

More information

the Simulation of Dynamics Using Simulink

the Simulation of Dynamics Using Simulink INTRODUCTION TO the Simulation of Dynamics Using Simulink Michael A. Gray CRC Press Taylor & Francis Croup Boca Raton London New York CRC Press is an imprint of the Taylor & Francis Group an informa business

More information

Resource Inspections Canada Inc. Certification Scheme Requirements

Resource Inspections Canada Inc. Certification Scheme Requirements 1. Purpose To describe the requirements for certification scheme for certified calibration laboratory technician for dimensional calibrations conducted by Resource Inspections Canada Incorporated. This

More information

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS 5-0. International Measurement Evaluation Program Sample: Pb in river water (blind sample) :

More information

PXI Vector Network Analyzer

PXI Vector Network Analyzer CONFIGURATION GUIDE PXI Vector Network Analyzer M9370A 300 khz to 4 GHz M9371A 300 khz to 6.5 GHz M9372A 300 khz to 9 GHz M9373A 300 khz to 14 GHz M9374A 300 khz to 20 GHz M9375A 300 khz to 26.5 GHz Drive

More information

Resource Inspections Canada Inc. Certification Scheme Requirements

Resource Inspections Canada Inc. Certification Scheme Requirements 1. Purpose To describe the requirements for certification scheme for certified calibration laboratory technician for mechanical calibrations conducted by Resource Inspections Canada Incorporated. This

More information

ATLAS Analysis Workshop Summary

ATLAS Analysis Workshop Summary ATLAS Analysis Workshop Summary Matthew Feickert 1 1 Southern Methodist University March 29th, 2016 Matthew Feickert (SMU) ATLAS Analysis Workshop Summary March 29th, 2016 1 Outline 1 ATLAS Analysis with

More information

Introduction to Simulink Design Optimization

Introduction to Simulink Design Optimization 2009 The MathWorks, Inc. Introduction to Simulink Design Optimization Estimate and optimize Simulink model parameters Arkadiy Turevskiy and Alec Stothert Introduction to Simulink Design Optimization Estimate

More information

GEA GROUND AND BUILDING VIBRATION

GEA GROUND AND BUILDING VIBRATION GEA GROUND AND BUILDING VIBRATION GEA, the new integrated sensor for vibrations measurement within civil environment. Developed using MEMS technology, conforms DIN 4150-3 for evaluation of building structural

More information

Copyright ANRITSU. All rights reserved.

Copyright ANRITSU. All rights reserved. --------------- ShockLine VNA Software If there is a software/firmware update question, please contact Anritsu service support at https://techsupport.anritsu.com, and then click on "Technical Support"

More information

Agilent Training and Application Engineering Services Catalog. Product Services Training Application Services

Agilent Training and Application Engineering Services Catalog. Product Services Training Application Services Application Engineering Services Catalog Product Services Training Application Services Catalog Overview Helping you overcome your test and measurement obstacles This catalog provides an overview of the

More information

8960 Fading with the PXB

8960 Fading with the PXB 8960 Fading with the PXB The PXB can connect with an Agilent E5515C/8960 Wireless Communication Test Set to form a complete solution for performing faded signal tests on cdma2000, 1xEV-DO, W-CDMA/HSDPA

More information

AP Physics 1 and 2 Summer Assignment

AP Physics 1 and 2 Summer Assignment AP Physics 1 and 2 Summer Assignment Due: First Day of Class Welcome to AP Physics! You are responsible for the material covered in the first three chapters of your textbook. The questions that follow

More information

J2EE Development. Course Detail: Audience. Duration. Course Abstract. Course Objectives. Course Topics. Class Format.

J2EE Development. Course Detail: Audience. Duration. Course Abstract. Course Objectives. Course Topics. Class Format. J2EE Development Detail: Audience www.peaksolutions.com/ittraining Java developers, web page designers and other professionals that will be designing, developing and implementing web applications using

More information

cultural information in Germany

cultural information in Germany The BAM portal: one access point to cultural information in Germany Workshop on Indexing and Investigation of Artists Publications Bremen, Neues Museum Weserburg November 14th, 2009 Jörn Sieglerschmidt

More information

BREAKOUT 2: GAW QUALITY ASSURANCE

BREAKOUT 2: GAW QUALITY ASSURANCE BREAKOUT 2: GAW QUALITY ASSURANCE Moderators: Emilio Cuevas and Herman Smit Rapporteurs: Dagmar Kubistin and Elke Ludewig Tuesday Afternoon 11 April 14:00-17:00 Salle C1 GAW Symposium at WMO-Geneva 10-13

More information

Techniques for Precise Measurement Calibrations in the Field

Techniques for Precise Measurement Calibrations in the Field Techniques for Precise Measurement s in the Field Using FieldFox handheld analyzers up to 26.5 GHz Application Note This application note, which applies to cable and antenna and vector network analysis,

More information

Device for Precise Packet Delay Measurement

Device for Precise Packet Delay Measurement Device for Precise Packet Delay Measurement Jan Breuer 1, Vojtěch Vigner 2 and Jaroslav Roztocil 3 1, 2, 3 Department of Measurement, Faculty of Electrical Engineering, Czech Technical University in Prague,

More information

Fair, Optimal or Detrimental? Environmental vs. Strategic Use of Border Carbon Adjustment

Fair, Optimal or Detrimental? Environmental vs. Strategic Use of Border Carbon Adjustment Fair, Optimal or Detrimental? Environmental vs. Strategic Use of Border Carbon Adjustment RFF/ENTWINED Research Program Workshop Washington DC, September 4/5, 2012 DART team: Matthias Weitzel (IfW Kiel)

More information

Automated Visualization Support for Linked Research Data

Automated Visualization Support for Linked Research Data Automated Visualization Support for Linked Research Data Belgin Mutlu 1, Patrick Hoefler 1, Vedran Sabol 1, Gerwald Tschinkel 1, and Michael Granitzer 2 1 Know-Center, Graz, Austria 2 University of Passau,

More information

Implementation of PAT Key elements for success.

Implementation of PAT Key elements for success. Implementation of PAT Key elements for success. Dr. Kjell FRANCOIS PAT consultant PAT Event, Frankfurt, October 6 th How to implement a PAT enabled framework? Page 2 Can you still see the forest through

More information

Presenters Manual. Concepts of Graphics and Illustrations. Effective from: April 2009 Ver. 1.0

Presenters Manual. Concepts of Graphics and Illustrations. Effective from: April 2009 Ver. 1.0 Presenters Manual Concepts of Graphics and Illustrations Effective from: April 2009 Ver. 1.0 Amendment Record Version No. Effective Date Change Replaced Pages 1.0 April 2009 New - Arena Multimedia 2 Presenters

More information

Appendix Q. Modelling of complex satellite manoeuvres with ESATAN-TMS. Nicolas Bures (ITP Engines UK Ltd, United Kingdom)

Appendix Q. Modelling of complex satellite manoeuvres with ESATAN-TMS. Nicolas Bures (ITP Engines UK Ltd, United Kingdom) 227 Appendix Q Modelling of complex satellite manoeuvres with ESATAN-TMS Nicolas Bures (ITP Engines UK Ltd, United Kingdom) 228 Modelling of complex satellite manoeuvres with ESATAN-TMS Abstract Requirements

More information

modeling and simulation, uncertainty quantification and the integration of diverse information sources

modeling and simulation, uncertainty quantification and the integration of diverse information sources modeling and simulation, uncertainty quantification and the integration of diverse information sources C. Shane Reese 1 DoD/NASA Statistical Engineering Leadership Webinar, May 2017 1 Department of Statistics

More information

EEMI450 and global 450mm Cooperation

EEMI450 and global 450mm Cooperation ISS Europe 2009 EEMI450 and global 450mm Cooperation Bas van Nooten - Spokesman EEMI450 - Semi Consulting on behalf of ASM Overview EEMI450 International Collaboration Enable450 EEMI450 European Equipment

More information

Ball Aerospace s Open Source Command and Control System. Ryan Melton Ball Aerospace & Technologies Corp. Boulder, CO

Ball Aerospace s Open Source Command and Control System. Ryan Melton Ball Aerospace & Technologies Corp. Boulder, CO Ball Aerospace s Open Source Command and Control System Ryan Melton Ball Aerospace & Technologies Corp. Boulder, CO 8/5/2016 VISION To enable small satellite developers to easily and cost effectively command

More information

User Entry of the Keysight (Agilent/HP) 8510 Calibration Standards Definitions for Millimeter Wave Configuration

User Entry of the Keysight (Agilent/HP) 8510 Calibration Standards Definitions for Millimeter Wave Configuration User Entry of the Keysight (Agilent/HP) 8510 Calibration Standards Definitions for Millimeter Wave Configuration The purpose of this procedure is to guide an 8510 millimeter wave user through the completion

More information

Advanced architecture and services Implications of the CEF Networks workshop

Advanced architecture and services Implications of the CEF Networks workshop Copenhagen, November 21th, 2012 Network Architects Workshop 1 Advanced architecture and services Implications of the CEF Networks workshop Michal Hažlinský Lada Altmannová, Jan Nejman, Stanislav Šíma,

More information

TTR500 Series Vector Network Analyzers Demonstration Guide

TTR500 Series Vector Network Analyzers Demonstration Guide xx ZZZ TTR500 Series Vector Network Analyzers Demonstration Guide *P071349301* 071-3493-01 xx ZZZ TTR500 Series Vector Network Analyzers Demonstration Guide Register now! Click the following link to protect

More information

Wish List CERT. Tom Longstaff

Wish List CERT. Tom Longstaff Wish List Tom Longstaff Network Group Software Engineering Institute Carnegie Mellon University Pittsburgh, PA 15213-3890 The Network Group is part of the Software Engineering Institute. The Software Engineering

More information

WG1: RELIABLE, ECONOMIC AND EFFICIENT SMART GRID SYSTEM

WG1: RELIABLE, ECONOMIC AND EFFICIENT SMART GRID SYSTEM WG1: RELIABLE, ECONOMIC AND EFFICIENT SMART GRID SYSTEM 2 SUMMARY 1. ETIP-SNET s role is to guide Research, Development & Innovation (RD&I) to support Europe s energy transition. 2. WG1 is focused on system

More information

September 13, 2016 Session 1

September 13, 2016 Session 1 Premium Archive Session 1 2016 BiTS Workshop Image: 一花一菩提 /HuiTu.com Premium Archive Presentation / Copyright Notice The presentations in this publication comprise the pre-workshop Proceedings of the BiTS

More information

SensorLab2. In-the-field IoT Validation Platform

SensorLab2. In-the-field IoT Validation Platform In-the-field IoT Validation Platform SensorLab2, presented by Q. Lampin, Orange Labs 1 a look back Early IoT years A typical experiment few nodes custom hardware custom observation tools before 2006 SensorLab2,

More information

Software Release Notes

Software Release Notes Fixed a bug related to IFBW settings below 10 Hz in the S5048 and S7530 models Changed the application icon Version 15.4.0 IMPORTANT: All instruments in the (reversing 2-Port VNAs) now share a common installer

More information

Exercise Sensor Networks - (till June 20, 2005)

Exercise Sensor Networks - (till June 20, 2005) - (till June 20, 2005) Exercise 8.1: Signal propagation delay A church bell is rang by a digitally triggered mechanics. How long does the sound travel to a sensor node in a distance of 2km if sound travels

More information

Quality assurance and calibration tasks in the scope of multi-sensor systems

Quality assurance and calibration tasks in the scope of multi-sensor systems Quality assurance and calibration tasks in the scope of multi-sensor systems FIG Working Week 2015 From the Wisdom of the Ages to the Challenges of the Modern World Sofia, May 19, 2015 Jens-André Paffenholz,

More information

Reference Guide. Agilent Technologies Electronic Calibration Modules. RF Two-Port 85091C 85092C 85093C 85096C 85098C 85099C. RF Four-Port N4431B

Reference Guide. Agilent Technologies Electronic Calibration Modules. RF Two-Port 85091C 85092C 85093C 85096C 85098C 85099C. RF Four-Port N4431B Reference Guide Agilent Technologies Electronic Calibration Modules RF Two-Port 8509C 85092C 85093C 85096C 85098C 85099C RF Four-Port N443B Microwave Two-Port N4690B N469B N4692A N4693A N4694A N4696B Microwave

More information

Horizontal scale calibration of theodolites and total station using a gauge index table

Horizontal scale calibration of theodolites and total station using a gauge index table Journal of Physics: Conference Series PAPER OPEN ACCESS Horizontal scale calibration of theodolites and total station using a gauge index table To cite this article: L H B Vieira et al 015 J. Phys.: Conf.

More information

Cross-Linking with the Particle Data Group

Cross-Linking with the Particle Data Group Cross-Linking with the Particle Data Group Juerg Beringer Particle Data Group Lawrence Berkeley National Laboratory Outline: Introduction Interaction with SPIRES Cross-linking with PDG Identifiers Status

More information

ArcGIS Enterprise: Sharing Imagery. Zikang Zhou Imagery and Raster team

ArcGIS Enterprise: Sharing Imagery. Zikang Zhou Imagery and Raster team ArcGIS Enterprise: Sharing Imagery Zikang Zhou Imagery and Raster team ArcGIS Enterprise: Sharing Imagery PowerPoint slides will be available online. Send me an E-mail if you need it faster: zzhou@esri.com

More information

Direct Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements

Direct Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements Direct Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements Introduction For full two-port S-parameter measurements to extend PNA-C vector network

More information

EHT Math Curriculum

EHT Math Curriculum 07-08 EHT Math Curriculum Grade Level: 4th Created by: Pacing Guide Committee KEY: Major (70%) Supporting (0%) Additional (0%) Curriculum Pacing EHT Curriculum Pacing CCSS Code CCSS Standard Description

More information

Appendix E: Software

Appendix E: Software Appendix E: Software Video Analysis of Motion Analyzing pictures (movies or videos) is a powerful tool for understanding how objects move. Like most forms of data, video is most easily analyzed using a

More information

The Virtual CMM a software tool for uncertainty evaluation practical application in an accredited calibration lab

The Virtual CMM a software tool for uncertainty evaluation practical application in an accredited calibration lab The Virtual CMM a software tool for uncertainty evaluation practical application in an accredited calibration lab Michael Trenk *, Matthias Franke **, Dr. Heinrich Schwenke ** * FEINMESS GmbH&Co. KG **

More information

THE EPIC SIMULATOR AND PILE-UP MODELLING. Prashin Jethwa EPIC BOC /3/2012

THE EPIC SIMULATOR AND PILE-UP MODELLING. Prashin Jethwa EPIC BOC /3/2012 THE EPIC SIMULATOR AND PILE-UP MODELLING Prashin Jethwa EPIC BOC 2012 7/3/2012 OUTLINE Introduction to the EPIC simulator What is it? How does it work? Validation Pile-up modelling Flux losses Spectral

More information

Overview of the CRISP proposal

Overview of the CRISP proposal Overview of the CRISP proposal Context Work Package Structure IT Work Packages Slide: 1 Origin of the CRISP proposal Call publication: End of July 2010 deadline towards end of 2010 4 topics concerning

More information

Agilent USB3, Slide - 1. Agilent. USB3 Test Fixture Characterization. 10 MHz to 20 GHz March 12,

Agilent USB3, Slide - 1. Agilent. USB3 Test Fixture Characterization. 10 MHz to 20 GHz March 12, Agilent USB, Slide 1 Agilent USB Test Fixture Characterization 10 MHz to 20 GHz March 12, 2009 Agilent USB, Slide 2 Measurement Summary A prototype Agilent USB test fixture was measured using a 4port PNA,

More information

Topic 01. Software Engineering, Web Engineering, agile methodologies.

Topic 01. Software Engineering, Web Engineering, agile methodologies. Topic 01 Software Engineering, Web Engineering, agile methodologies. 1 What is Software Engineering? 2 1 Classic Software Engineering The IEEE definition: Software Engineering is the application of a disciplined,

More information

ROS Interfaced Autonomous Control System in the Loop Real time CarMaker simulated sensor data for system under test

ROS Interfaced Autonomous Control System in the Loop Real time CarMaker simulated sensor data for system under test ROS Interfaced Autonomous Control System in the Loop Real time CarMaker simulated sensor data for system under test Graham Lee*, Zaour Raouf, Abdul Nasser Raouf, Jakobus Groenewald and Gunwant Dhadyalla

More information

Publishing data for maximized reuse

Publishing data for maximized reuse Publishing data for maximized reuse Pieter Colpaert Ghent University - iminds - Multimedia Lab and Open Knowledge Central pieter.colpaert@okfn.org Abstract. Two movements are currently influencing the

More information

Ch En 475: Introduction to Instrumentation and Signal Processing with Labview

Ch En 475: Introduction to Instrumentation and Signal Processing with Labview Ch En 475: Introduction to Instrumentation and Signal Processing with Labview Measurement Instrumentation Rapid, on-line measurement of temperature, pressure, liquid level, flow rate and composition is

More information

Investigating the volumetric performance of multi-axis measurement arms

Investigating the volumetric performance of multi-axis measurement arms Investigating the volumetric performance of multi-axis measurement arms J.Singh, M.Hughes & J N Petzing Wolfson School of Mechanical & Manufacturing Engineering Loughborough Universty, UK Abstract Multi-axis

More information

Protection Profiles for Signing Devices

Protection Profiles for Signing Devices www.thales-esecurity.com Protection Profiles for Signing Devices Report on CEN Standardisation Activities on Security of Electronic Signatures 2 / Topics EU Legislation driving standardisation for Electronic

More information

Council of the European Union Brussels, 6 March 2015 (OR. en)

Council of the European Union Brussels, 6 March 2015 (OR. en) Council of the European Union Brussels, 6 March 2015 (OR. en) 6860/15 LIMITE DAPIX 32 NOTE From: To: Subject: German delegation Working Party on Information Exchange and Data Protection (DAPIX) Improving

More information