EQUIPMENT FOR ATEX APPARECCHI DI ILLUMINAZIONE A LED LED LIGHTING EQUIPMENT

Size: px
Start display at page:

Download "EQUIPMENT FOR ATEX APPARECCHI DI ILLUMINAZIONE A LED LED LIGHTING EQUIPMENT"

Transcription

1 CO SI ME... EQUIPMENT FOR ATEX APPARECCHI DI ILLUMINAZIONE A LED LED LIGHTING EQUIPMENT

2 LED LIGHTING FIXTURES PRO 12 T6 Gb Zone 1 - Zone 21 - Zone 2 - Zone C Installazione : universale con staffa in acciaio inoxaisi 304 Ingresso : N 1 pressacavo M20x1.5 2x1,5 mm² Cable entry : N 1 cable gland M20x1.5 Potenza : Vedi tabella 230Vac (altre tensioni a richiesta) Power : See table Voltage : 230Vac (other voltage on demand) Sistema lenti FRAEN secondarie FRAEN Secondary lens system [W] N led Lente Lens PRO 12230AC Vac 2,5 PRO 12230AC Vac 2,7 PRO 1224DC Vdc 2,5 PRO 1224DC Vdc 2,7 K1 CO.SI.ME. srl - via Asiago, Milan ITALY info@cosime.com

3 LED LIGHTING FIXTURES PRO 24 T6 Gb Zone 1 - Zone 21 - Zone 2 - Zone C Installazione : universale con staffa in acciaio inoxaisi 304 Ingresso : N 1 pressacavo M20x1.5 2x1,5 mm² Cable entry : N 1 cable gland M20x1.5 Potenza : Vedi tabella 230Vac (altre tensioni a richiesta) Sistema lenti FRAEN secondarie FRAEN Secondary lens system KHATOD NACTUS compatibile Compatible KHATOD NACTUS Power : Voltage : See table 230Vac (other voltage on demand) PRO 24230AC44 PRO 24230ACK.. [W] N led Lente Lens PRO 24230AC Vac 6,5 PRO 24230AC Vac 7,0 PRO 24230ACK KATHOD page Y5 230Vac 7,2 PRO 24230AC Vdc 6,5 PRO 24230AC Vdc 7,0 PRO 24230ACK KATHOD page Y5 24Vdc 7,2 K2 CO.SI.ME. srl - via Asiago, Milan ITALY info@cosime.com

4 LED LIGHTING FIXTURES PRO 48 T6 Gb Zone 1 - Zone 21 - Zone 2 - Zone C Installazione : universale con staffa in acciaio inoxaisi 304 Ingresso : N 1 pressacavo M20x1.5 2x1,5 mm² Cable entry : N 1 cable gland M20x1.5 Potenza : Vedi tabella 230Vac (altre tensioni a richiesta) Sistema lenti FRAEN secondarie FRAEN Secondary lens system KHATOD NACTUS compatibile Compatible KHATOD NACTUS Power : Voltage : See table 230Vac (other voltage on demand) PRO 24230AC44 PRO 24230ACK.. [W] N led Lente Lens PRO 48230AC Vac 13,0 PRO 48230AC Vac 14,0 PRO 48230ACK KATHOD page Y5 230Vac 14,4 PRO 4824DC Vdc 13,0 PRO 4824DC Vdc 14,0 PRO 4824DCK KATHOD page Y5 24Vdc 14,4 K3 CO.SI.ME. srl - via Asiago, Milan ITALY info@cosime.com

5 LENTI PER LED LENSES FOR LED T6 PRO Gb Zone 1 - Zone 21 - Zone 2 - Zone 22 T R+40 C Descrizione Description Altezza installazione Installation height Tipo fascio Beam type ASYMM 12 meters 120 SYMM 10 meters 90 SYMM 60 x meters ASYMM 18 meters 120 SYMM 15 meters 90 SYMM 9 meters 60 x meters T R Ampiezza fascio Width beam KNAC2401 KNAC2404 KNAC2410 KNAC2409 KNAC4809 KNAC4802 KNAC4808 KNAC4807 K4 CO.SI.ME. srl - via Asiago, Milan ITALY ) *info@cosime.com

6 LED LIGHTING FIXTURES PRO 12 T6 Gb Zone 1 - Zone 21 - Zone 2 - Zone C Installazione : cavalletto in acciaio verniciato giallo oppure cavo 2x1.5 H07RN-F 2x1,5 mm² Ingresso : N 1 pressacavo M20 Spina : II2G Exd IIC II2D Ex tb IIIC codice BP da utilizzare con presa FSQ non compresa or cable 2x1.5 H07RN-F 2x1,5 mm² Cable entry : N 1 cable gland M20 Plug : II2G Exd IIC II2D Ex tb IIIC code BP to use with scocket FSQ not included Potenza : Vedi tabella 24Vdc - 24Vac - 230Vac Power : See table Voltage : 24Vdc - 24Vac - 230Vac X [mm] [W] N led PRO 12EX230ACP Vac 7,2 PRO 12EX230AC44P Vac 7,2 PRO 12EX24DCP Vdc 7,0 PRO 12EX24DC44P Vdc 7,0 PRO 12EX24ACP Vac 7,2 PRO 12EX24AC44P Vac 7,2 K5 CO.SI.ME. srl - via Asiago, Milan ITALY info@cosime.com

7 APPARECCHI DI ILLUMINAZIONE A LED LED LIGHTING FIXTURES PRO 12 Installazione : cavalletto in acciaio verniciato giallo oppure cavo 2x1.5 H07RN-F 2x1,5 mm² Ingresso : N 1 pressacavo M16x1.5 IP Ip66 Ip66-40 C +55 C Spina : in poliammide da utilizzare con presa CEE aluminium or cable 2x1.5 H07RN-F 2x1,5 mm² Cable entry : N 1 cable gland M16x1.5 Plug : polyammide plug to use with CEE socket Potenza : Vedi tabella 24Vdc - 24Vac - 230Vac Power : See table Voltage : 24Vdc - 24Vac - 230Vac X [mm] [W] N led PRO 1224DC Vdc 7,0 PRO 1224DC Vdc 7,2 PRO 1224AC Vac 7,1 PRO 1224AC Vac 7,4 K6 CO.SI.ME. srl - via Asiago, Milan ITALY info@cosime.com

Installation Equipments

Installation Equipments Installation Equipments BCZ8 Series Explosion-proof and Socke ts to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 Four enclosure types; Four current ratings (1A, 32A, 3A, 12A);

More information

Arredo urbano / Illuminazione stradale - Urban light / Street light LED Minispluga - LED Spluga - LED Maxispluga

Arredo urbano / Illuminazione stradale - Urban light / Street light LED Minispluga - LED Spluga - LED Maxispluga LED Minispluga - LED Spluga - LED Maxispluga Gamma di apparecchi a LED per illuminazione di aree urbane. Ideale per l illuminazione di strade, parcheggi, aree residenziali. Installazione: su palo con codolo

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx FTZU 14.0004X Current

More information

Loads and Motor Switchgears

Loads and Motor Switchgears 5 Loads and Motor Switchgears Motor Switches BLK Series Explosion-proof Motor Switches to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 Class I, Zone 1 and Zone 2 Class I, Division

More information

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified

More information

ZQxSERVER. Server Ethernet con interfacce I/O, DALI e wireless 868MHz

ZQxSERVER. Server Ethernet con interfacce I/O, DALI e wireless 868MHz datasheet Server con interfacce I/O, e wireless permette la configurazione, la gestione ed il monitoraggio dei dispositivi utilizzati nei sistemi ZETAQLAB. Grazie alle varie interfacce di comunicazione

More information

NAMUR INDUCTIVE SENSOR ATEX/IECEx

NAMUR INDUCTIVE SENSOR ATEX/IECEx INDUCTIVE SENSORS NAMUR INDUCTIVE SENSOR ATEX/IECEx CYLINDRICAL HOUSING 6, Dia. M8MM4MM WIRES D.C. VERSION N CONFORMING: Directive ATEX 94/9/CE Group II Category Gas G (Zone 0) and Dust D (Zone ) (Reference

More information

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET WirelessHART components Gateway and accessories 2 Measurement made easy The ABB offering on WirelessHART accessories connect wireless sensors to the automation

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

HAZARDOUS AREA PTZ IP NETWORK CAMERA

HAZARDOUS AREA PTZ IP NETWORK CAMERA ZCAM4-AX HAZARDOUS AREA PTZ IP NETWORK CAMERA DS-026 Issue 02 ZIZCAM Ltd are a UK based manufacturer of CCTV Cameras for use in the Hazardous Oil, Gas and Petrochemical industries. Consequently our products

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Ex emergency pull-wire switches Ex ZS 71

Ex emergency pull-wire switches Ex ZS 71 Features/Options: Ex zone 1 and 21 Metal enclosure 2 contacts Wire length up to 35 m Small design Release by push-button (VD) Available without unlocking mechanism (per EN 60947-5-1) Wire pull and breakage

More information

Operating pressure (bar)

Operating pressure (bar) / poppet valves electromagnetic actuated, directly controlled G /4, /4 NPT, G /, / NPT or flanged with NAMUR Interface Main application: single operated actuators for plants Valves for safety systems up

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

M C. Ex d M-0... control, monitoring and signalling devices

M C. Ex d M-0... control, monitoring and signalling devices Ex d M-0... control, monitoring and signalling devices M-0 M-0 series control, monitoring and signalling devices are installed as external accessories on Cortem 'Ex d' enclosures used in any industrial

More information

ELETTRONICA. 1W 350 ma CONTROLLO DI CORRENTE / 1W 350 ma CURRENT CONTROLLER. 1,5W 500 ma CONTROLLO DI CORRENTE / 1,5W 500 ma CURRENT CONTROLLER

ELETTRONICA. 1W 350 ma CONTROLLO DI CORRENTE / 1W 350 ma CURRENT CONTROLLER. 1,5W 500 ma CONTROLLO DI CORRENTE / 1,5W 500 ma CURRENT CONTROLLER 380 1W 350 ma CONTROLLO DI CORRENTE / 1W 350 ma CURRENT CONTROLLER N Min - Max LED ECG.0012.0 10g Ø12x65 mm IP65 - Min 1 - Max 5 LED Max 1 High Power LED E1 1,5W 500 ma CONTROLLO DI CORRENTE / 1,5W 500

More information

HAZARDOUS AREA DAY/NIGHT PTZ HD CAMERA

HAZARDOUS AREA DAY/NIGHT PTZ HD CAMERA ZCAM4 HAZARDOUS AREA DAY/NIGHT PTZ HD CAMERA DS-023 Issue 02 ZIZCAM Ltd are a UK based manufacturer of CCTV Cameras for use in the Hazardous Oil, Gas and Petrochemical industries. Consequently our products

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Operating pressure. N/en/en

Operating pressure. N/en/en 660, 8007 NAMUR /, / & / way spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple

More information

Operating pressure. N/en/en

Operating pressure. N/en/en 660, 8007 NAMUR /, / & / spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple design

More information

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT 70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination

More information

Operating pressure (bar) kv factor (m 3 /h) *3)

Operating pressure (bar) kv factor (m 3 /h) *3) / way poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar

More information

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Universal Safety IO System board for Honeywell Universal Process IO For 6-channel cards USIO and UPIO For 6 modules Recommended modules: HiC8R (DI), HiC85R

More information

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-438-2FX

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-438-2FX Panel PC, AMD GX Ce i7, 15" display, sunlight-readable 1200 cd/m² Rugged design:, shock, vibration and seawater-proof, temperature range -40 C to +65 C Compact, lightweight HMI design < 25 kg / 55 lbs

More information

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free

More information

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-498-2TX

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-498-2TX Panel PC, AMD GX or Core i7, 21.5" display, sunlight- readable 1000 cd/ m² Rugged design:, shock, vibration and seawater- proof, temperature range - 40 C to +65 C Full HD resolution (1920 x 1080) Optional

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK MT-438-1TX

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK MT-438-1TX Panel PC, AMD GX Ce i7, 15" display, sunlight-readable 1200 cd/m² Rugged design:, shock, vibration and seawater-proof, temperature range -40 C to +65 C Compact, lightweight HMI design < 18 kg / 40 lbs

More information

Grounding Monitoring Device Series 8485

Grounding Monitoring Device Series 8485 www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with

More information

XLF. Ex d. - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance

XLF. Ex d. - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance XLF - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance Polycarbonate Fresnel lens Fixture without Fresnel lens Painted aluminium body E.2

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Conveyor Belt Alignment Switches from IDEM

Conveyor Belt Alignment Switches from IDEM Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are

More information

Coil Type 3009M. This document cannot be modified without the approval of the Certification Institute 1/4

Coil Type 3009M. This document cannot be modified without the approval of the Certification Institute 1/4 Coil Type 3009M Coil Type 3009M UE DECLARATION OF CONFORMITY 1/4 Coil Type 3009M COIL 3009M II 2G Ex mb IIC Tx Gb II 2D Ex tb IIIC Tx C Db to be used in potentially explosive atmosphere We, AMISCO S.p.A.,

More information

Linear Luminaire with LED Series 6412/5

Linear Luminaire with LED Series 6412/5 > For use in Zones 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless

More information

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel. February 23, 2018 Annexe to: IECEx CML 15.0097X Issue 4 Applicant: Apparatus: HMI Elements Limited 470-Z1 Module Description of Equipment The 470-Z1 is a mains supplied, transportable hazardous area

More information

80265 series, 3/2 Indirect solenoid actuated poppet valve

80265 series, 3/2 Indirect solenoid actuated poppet valve > > Port size: G/... G > > High flow rate > > Optionally air pilot operated > > High repeatability of switching time > > Variable valve solenoid combination Technical features Medium: Compressed air, filtered,

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Linear Luminaire with LED Series 6012/5

Linear Luminaire with LED Series 6012/5 > For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

Apparecchi a sospensione - Suspended-mount light fittings HIGH-SPOT. arcluce.it. high spot

Apparecchi a sospensione - Suspended-mount light fittings HIGH-SPOT. arcluce.it. high spot Apparecchi a sospensione - Suspended-mount light fittings HIGH-SPOT 235 APPARECCHIO Anello in alluminio pressofuso. Testate e traversini in alluminio estruso. Verniciatura a polvere antingiallimento stabilizzata

More information

Grounding Monitoring Device Series 8485

Grounding Monitoring Device Series 8485 www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with

More information

Server Specifications

Server Specifications , page 1 Power Cord s, page 6 This appendix lists the physical, environmental, and power specifications for the server. Physical s, on page 1 Environmental s, on page 2 Power s, on page 2 Physical s The

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

HAZARDOUS AREA DAY/NIGHT HD CAMERAS

HAZARDOUS AREA DAY/NIGHT HD CAMERAS ZCAM2 HAZARDOUS AREA DAY/NIGHT HD CAMERAS DS-021 Issue 01 ZIZCAM Ltd are a UK based manufacturer of CCTV Cameras for use in the Hazardous Oil, Gas and Petrochemical industries. Consequently our products

More information

Digital switching module for 2-wire system Art. 1404

Digital switching module for 2-wire system Art. 1404 EN TECHNICAL MANUAL MIN MAX S1 1 2 3 4 5 6 7 8 S2 1 2 3 4 5 6 7 8 Ar t. 1404 LM LM LS LS LPin LPout B JP1 A Digital switching module for 2-wire system Art. 1404 Table of contents Warning Description...

More information

Product manual plug, sockets and coupler 16 A.- Z0251

Product manual plug, sockets and coupler 16 A.- Z0251 Product manual plug, sockets and coupler 16 A.- Z0251 INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these

More information

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8200 Stationary gas detector (CatEx) Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result

More information

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous

More information

11W & 22W: Ex d e mb IIC T6 Gb, Ex tb IIIC T85 C Db II 2GD ABS Assessed: #11-LD PDA

11W & 22W: Ex d e mb IIC T6 Gb, Ex tb IIIC T85 C Db II 2GD ABS Assessed: #11-LD PDA Application: The Dialight SafeSite LED Bulkhead luminaire with its low profile, rugged design ensures long life and high reliability for a wide variety of Hazardous Area applications. Offered in 11W, 22W

More information

MASSMAX Series MASSMAX

MASSMAX Series MASSMAX MASSMAX 6400 Series MASSMAX MASSMAX 2 TOKYO KEISO CO., LTD. MASSMAX TOKYO KEISO CO., LTD. 3 MASSMAX Explosionproof specifications TIIS explosionproof type 1) Compact type MMM6400C-JEx a) Type of protection

More information

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mounting Corrosion resistant housing in SS316 available Selectable Units for Mass, Volume, Density

More information

ISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

ISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves *STR - TX version (SX, SXP) / & / > > Sub-base mounted, 99- s, or > > Specially coated glandless spool and sleeve for long trouble-free life > > Integral flow regulators available on and s for cylinder

More information

3500/15 Power Supply. Description

3500/15 Power Supply. Description 3500/15 Power Supply Description The 3500 Power Supplies are half-height modules and must be installed in the specially designed slots on the left side of the rack. The 3500 rack can contain one or two

More information

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mounting Corrosion resistant housing in SS316 available Selectable Units for Mass, Volume, Density

More information

BX80 series High resolution cubic housing area sensor

BX80 series High resolution cubic housing area sensor series sensor warranty features warranty Controlled heightt mm Operating up to m Microprocessor based circuit Sensitivity adjustment Strong Special version with metallic enclosure for high-duty use Protection

More information

Load Disconnect Switches and Motor Switches

Load Disconnect Switches and Motor Switches Load Disconnect Switches and Motor Switches 594 Load Disconnect Switches and Motor Switches Contents Load Disconnect Switches and Motor Switches Safety Switches made of Resin 10, 12/16, 16, 20, 25, 40,

More information

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring 3500/15 Power Supply Bently Nevada* Asset Condition Monitoring Description The 3500 Power Supplies are half-height modules and must be installed in the specially designed slots on the left side of the

More information

Tubular Light Fitting with LED Series 6036

Tubular Light Fitting with LED Series 6036 > Extremely robust luminaire design for rough ambient conditions > Very lightweight and vibration resistant LED light fitting > Extremely long service life due to LED used > High power LEDs including driver

More information

ISOMAG HIGH PERFORMANCE CONVERTER THE FRIENDLY MAG METER GRAPHIC DISPLAY CONVERTER

ISOMAG HIGH PERFORMANCE CONVERTER THE FRIENDLY MAG METER GRAPHIC DISPLAY CONVERTER ISOMAG THE FRIENDLY MAG METER HIGH PERFORMANCE CONVERTER CONVERTER GRAPHIC DISPLAY CONVERTER The manufacturer guarantees only English text. T E C H N I C A L D A T A Material box AISI 304 / SS AISI 304

More information

ALIMENTATORI POWER SUPPLIES

ALIMENTATORI POWER SUPPLIES ALIMENTATORI POWER SUPPLIES ALIMENTATORI SPECIALI SPECIAL POWER SUPPLIES TL 1301 Alimentazione a 12 Vdc per sensori e altre apparecchiature. Ideale per piccoli spazi 12 Vdc power supply for detectors and

More information

KINAX WT720 absolute, programmable angular postion transmitter

KINAX WT720 absolute, programmable angular postion transmitter For industrial applications in rough environments KINAX WT720 is a robust, absolute angular position transmitter, which is particularly suited to applications in rough environments due to its unique capacitive

More information

DeltaV SIS TMConditioning Components

DeltaV SIS TMConditioning Components February 2016 Page 1 DeltaV SIS TMConditioning Components The DeltaV SIS conditioning components allow you to use the DeltaV SIS system with a variety of different field signal requirements. Enables diagnostics

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

Modbus Interfacing Version1.3 Release 0 of the 07 April 2017

Modbus Interfacing Version1.3 Release 0 of the 07 April 2017 Modbus Interfacing Version1.3 Release 0 of the 07 April 2017 Modbus specification 1.3.r00.docxx - Pag. 1/10 Contents 1 Modbus Connection... 3 1.1 Modbus configuration... 3 1.2 Modbus Functionality... 3

More information

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

Control Stations & Switches: Switches, Circuit Breakers and Break Glass Call Points SWE Series: 16 and 20 A Switches Increased Safety SWE Series: 16 and 2 A Switches Increased Safety 16 A Version - Type 1 16 A Version - Type 2 2 A Version Compliance Data: ATEX - IEC: Zone 1 & 2, 21 & 22 ATEX IEC CE Ex de IIC T6 Ex td A21 T8 C IP66 -

More information

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX Thin Client for panel mounting, 19" display, 1280 x 1024 pixels Zone 1, 2, 21, 22, can be installed in hazardous areas without additional enclosure All-round degree of protection, resistive foil touch

More information

Cradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N

Cradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N Cradle relay AC Cradle relay for alternating voltage, neutral, monostable. High-quality cradle relays for AC are installed as encapsulated flameproof elements in the MODEX enclosure. The IP 66 protection

More information

HERION SERIES Indirect solenoid actuated spool valves

HERION SERIES Indirect solenoid actuated spool valves HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free

More information

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06 PRODUCT MANUAL Rotork YTC Limited VERSION 1.06 Contents 1 Introduction... 3 1.1 General Information for the users... 3 1.2 Manufacturer Warranty... 3 1.3 Explosion Proof Warning... 4 2 Product Description...

More information

Evolution 05 and 12. Model

Evolution 05 and 12. Model 5MP or 12MP sensor and no moving parts 5MP sensor Up to 30 fps video stream at 1 MP and ¼ MP 0.2 lux minimum illumination 12MP high-resolution sensor Up to 30 fps at 2.0 MP 0.1 lux minimum illumination

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

Technical features. 12/ f. N/en

Technical features. 12/ f. N/en /, / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface Main application: single and double operated actuators TÜV-approval based

More information

FIT 2R. design Serge & Robert Cornelissen TRIMLESS FRAME

FIT 2R. design Serge & Robert Cornelissen TRIMLESS FRAME design Serge & Robert Cornelissen TRIMLESS FRAME Apparecchio da incasso a soffitto per l illuminazione di ampi spazi commerciali. Costruito in alluminio estruso verniciato a polveri previo trattamento

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection

Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection red-y industrial series product information Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection High accuracy for heavy duties: Mass Flow Meters & Controllers with IP67 & Ex Protection

More information

FLP Lens series for LG Innotek LEMWW35 1 LEDs

FLP Lens series for LG Innotek LEMWW35 1 LEDs FLP Lens series for LG Innotek LEMWW35 1 LEDs High efficiency Available in 5 different beam profiles Easy assembly The FLP lens offers five low-profile lenses specifically designed for the LEMWW35 LEDs

More information

PTDCD/40 PTDCD/40/S10 CONTROL SIGNAL * *0 10Vcc o 47 kω potenziometro lineare. 0 10Vcc or 47 kω linear potentiometer.

PTDCD/40 PTDCD/40/S10 CONTROL SIGNAL * *0 10Vcc o 47 kω potenziometro lineare. 0 10Vcc or 47 kω linear potentiometer. PTDCD/40 since 945 MASTER MAX 99 SAVE SAVE 0 SAVE 02 MAX 99 SAVE PTDCD/40/S0 COTRO SIGA * *0 0Vcc o 47 kω potenziometro lineare. 0 0Vcc or 47 kω linear potentiometer. Diagrammi di connessione Wiring diagrams

More information

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx Characteristics limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx Main Range of product Series name Product or component type Device short name Sensor design Body type Head type Material Fixing

More information

SKX 12 SKX 15. Zone. make your work surroundings safer IP 66

SKX 12 SKX 15. Zone. make your work surroundings safer IP 66 Zone 1 21 2 22 SKX 12 SKX 15 IP 66 C 20 +55 IM2 Enclosures made of glassfibre reinforced polyester resin 4 basic enclosure sizes Alone or in various combinations of merged set Equipped with built in devices

More information

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div. Termination Board HiCTB08-SCT-C-SC-RA Features Assembly For 8 modules V DC supply Supported signal types: DI/DO/AI/TI/AO Hazardous area: screw terminals, blue Safe area: screw terminals, black Function

More information

Polaris - Professional DATASHEET

Polaris - Professional DATASHEET Polaris - Professional DATASHEET JUNHO 2013 POLARIS PROFESSIONAL POLARIS Panel PC 10.4" POLARIS Panel PC 10.4" Explosion protection ATEX II 2G Ex db eb qb [ib op pr] IIC T4 II 2D Ex tb IIIC T120 C IP 6X

More information

Cable End Boxes Series 8146

Cable End Boxes Series 8146 > Enclosures glass fibre reforced polyester res > For termals from 35... 185 mm 2 > Rated operational current up to max. 400 A dependg on enclosure version and size > Degree of protection IP55 www.stahl.de

More information

Terminal Boxes Series 8118

Terminal Boxes Series 8118 > Enclosure made of glass fibre reinforced polyester resin > sizes available > Terminals and cable glands fitted to order > Enclosure design with integrated metal bracket for metal cable glands. > Degree

More information

EX-PROOF HD CAMERA IN A COMPACT DESIGN EC-910-AFZ-Full HD IP 10 x Zoom

EX-PROOF HD CAMERA IN A COMPACT DESIGN EC-910-AFZ-Full HD IP 10 x Zoom EX-PROOF HD CAMERA IN A COMPACT DESIGN EC-910-AFZ-Full HD IP 10 x Zoom The compact Full HD explosion-protected EC-910-AFZ Series is designed for effective video surveillance and process control in harsh

More information

red-y industrial series product information Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection

red-y industrial series product information Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection red-y industrial series product information Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection High accuracy for heavy duties: Mass Flow Meters & Controllers with IP67 & Ex Protection

More information

Minimum cross sectional area of Conductor mm²

Minimum cross sectional area of Conductor mm² Selection Overview Hawke International connectors are ideal for use in hazardous areas commonly found in Oil and Gas exploration, production and process plants. Their features, however, also offer numerous

More information

DECONTACTOR METAL 20 A/32 A/63 A/125 A/200 A

DECONTACTOR METAL 20 A/32 A/63 A/125 A/200 A X ECONTACTOR 20 A/32 A/63 A/125 A/200 A II2 G Ex de IIC, t 1 IP65 water-and dust-tight Integrated load-break switch Locking in connected or disconnected position by keying axis 178 X TECHNIL FEATURES X1

More information

Low-Intensity Infrared SAL

Low-Intensity Infrared SAL Low-intensity infrared SAL Page 1 6 Optical characteristics 10cd fixed or flashing 32cd fixed or flashing Colour aviation RED Horizontal beam 360 Vertical beam +6 +10 Low-Intensity 10 and 32cd with Stand-alone

More information

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment

More information

Technical Information Promonitor NRF560

Technical Information Promonitor NRF560 TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Explosion Proof Weighing System

Explosion Proof Weighing System Explosion Proof Weighing System Terminal ICS466x Safe and Compliant Intuitive and Easy to Use Versatile and Modular Ergonomic and Flexible Zone 1/21, Division 1 Safe and Accurate Weighing In Hazardous

More information

Supplementary Components WirelessHART products

Supplementary Components WirelessHART products Overview SITRANS AW200 WirelessHART adapter The SITRANS AW200 WirelessHART adapter is a batterypowered communication component, which integrates HART and 4 to 20 ma field devices into a WirelessHART network.

More information