1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES
|
|
- Beverly O’Neal’
- 6 years ago
- Views:
Transcription
1 INDOOR COILS C35 PRODUCT SPECIFICATIONS Upflow - Cased and Uncased Bulletin No February 208 Supersedes November to 5 Tons MODEL NUMBER IDENTIFICATION Unit Type C = Indoor Coil = Upflow Series C A - 2 F - Minor Revision Number Cabinet F = Cased Uncased coils have no designation FEATURES Nominal Cooling Capacity 8/24 =.5/2 tons 24 = 2 tons 30 = 2.5 tons 30/36 = 2.5/3 tons 36 = 3 tons 48 = 3.5/4 tons 49 = 4 tons 50/60 = 4/5 tons 60 = 5 tons CONTENTS Air Resistance... 5 C33 To C35 Cased Coil Cross-Reference... 5 C33 To C35 Uncased Coil Cross-Reference... 4 Dimensions... 7 Dimensions - Furnace/Coil Combined Dimensions... 3 Features... Model Number Identification... Optional Accessories... 4 Specifications... 3 WARRANTY All Covered Components - Limited warranty for five years in residential applications, one year warranty in non-residential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details. Metering Device 2 = Factory installed refrigerant metering device (RFC) Cabinet Width A = 4-/2 in. B = 7-/2 in. C = 2 in. D = 24-/2 in. Furnaces with the same letter designation will physically match the indoor coil. Uncased coils have different widths, but will fit the corresponding furnace cabinet. APPLICATIONS Lennox designed upflow indoor coils can easily be installed with most Lennox upflow furnaces. Applicable to expansion valve or RFCIV systems. RFCIV metering device is factory installed in C35 coils. RFCIV systems are applicable to certain air conditioners only. Expansion valve systems require field installed kit. See Product Specifications in section Air Conditioners for indoor coil applications and cooling capacities. See Product Specifications in section Heat Pump Outdoor Units for dual-fuel indoor coil applications and cooling and heating capacities.
2 FEATURES TESTING Tested with matching air conditioners and heat pump units. Rated in accordance with AHRI Standard 20/ conditions and DOE test procedures. Air resistance tests from Lennox Laboratory air test chamber. COIL CONSTRUCTION Lennox Quantum Coil - Aluminum tubing, hairpins, distributor and header tubes. Copper refrigerant sweat connections on both liquid and suction lines for easy brazing. Ripple-edged aluminum fins. Lanced fins provide maximum exposure of fin surface to air stream. Rifled tubing provides superior refrigerant heat transfer. Twin coil construction assembled in a A configuration for large surface area. Non-corrosive, UV-resistant polymer drain pan with dual fpt drain connections. Liquid line seal nut section furnished for installation of expansion valve. High pressure testing insures leakproof construction. Universal Piping Patch Plate (Uncased Coils Only) Piping patch plate is shipped with the coil for field installation over the liquid and suction lines. Plate has a scored line so it can be separated for different coils where the liquid and suction lines are farther apart. CABINET Construction - Cased (F) Coils Cabinets insulated with thick fiberglass insulation. Constructed of pre-painted heavy gauge steel. Flanges provided in outlet opening of cabinet for ease of plenum connection. Engaging holes furnished on cabinet for alignment with furnace. Removable panels provide access to coil. See dimension drawing. Furnace Match-Up Coils exactly match corresponding furnaces with same letter designation in model number. No adaptor required. Engaging holes furnished on cabinet for alignment. Uncased coils match furnaces without any overhang but require optional adaptor base or field fabricated transition to match furnace opening. Optional Accessories Adjustable Coil Adaptor/Seal For Uncased Coils Telescoping adaptor provides quick and easy installation in wide variety of applications. See dimension drawings and application drawings. Available ten pack kits. REFRIGERANT CONTROL CHOICE Optional Thermal Expansion Valve (TXV) Orifice Housing Suction Line O ring RFCIV Orifice (Shipped with Air Conditioner) O ring Strainer Sensing Bulb (furnished Liquid Line with TXV) Fitting All models applicable to Lennox RFCIV refrigerant metering system when matched with specific air conditioners. See Air Conditioners bulletins for applications. NOTE - In certain application the RFC orifice furnished with the coil must be replaced with the orifice furnished with the air conditioner. Refer to the air conditioner bulletin to determine if replacement is required. Optional expansion valve is required in most applications and must be ordered separately. Refrigerant Flow Control IV RFCIV accurately meters refrigerant in system. Refrigerant control is accomplished by exact sizing of refrigerant metering orifice. Principle of Lennox RFCIV system involves matching evaporator coil with proper bore size of orifice in metering device. RFCIV system equalizes pressure shortly after compressor stops, unit starts unloaded, eliminating need for additional controls. Optional Accessories Expansion Valve Kits Expansion valve available for field installation. See Air Conditioners or Heat Pump Outdoor Units Product Specifications for expansion valve kit selection. C35.5 to 5 Ton Indoor Coils / Page 2
3 SPECIFICATIONS.5 TO 2 TON General Data Uncased Model No. C35-8/24A-2 C35-8/24B-2 C35-24A-2 C35-24B-2 Line Connections in. Cased Model No. C35-8/24A-2F C35-8/24B-2F C35-24A-2F C35-24B-2F Nominal size - Tons.5 / 2.5 / Suction / vapor o.d. - sweat Liquid o.d. - sweat 3/8 3/8 3/8 3/8 Condensate drain (fpt) (2) (2) (2) (2) RFCIV metering device orifice size Indoor Coil Matching Lennox Furnace - Cabinet Width Designation Net face area sq. ft Tube diameter - in. 3/8 3/8 3/8 3/8 Number of rows Fins per inch A B A B Coil & Furnace Cabinet Width - in. 4-/2 7-/2 4-/2 7-/2 Shipping Data - lbs. Uncased Cased Uncased coils match furnaces without any overhang but require optional adaptor base or field fabricated transition to match furnace width. SPECIFICATIONS 2.5 TO 3 TON General Data Uncased Model No. C35-30A-2 C35-30B-2 C35-30/36A-2 C35-30/36B-2 Line Connections in. Cased Model No. C35-30A-2F C35-30B-2F C35-30/36A-2F C35-30/36B-2F Nominal size - Tons / / 3 Suction / vapor o.d. - sweat Liquid o.d. - sweat 3/8 3/8 3/8 3/8 Condensate drain (fpt) (2) (2) (2) (2) RFCIV metering device orifice size Indoor Coil Matching Lennox Furnace - Cabinet Width Designation Net face area sq. ft Tube diameter - in. 3/8 3/8 3/8 3/8 Number of rows Fins per inch A B A B Coil & Furnace Cabinet Width - in. 4-/2 7-/2 4-/2 7-/2 Shipping Data - lbs. Uncased Cased Uncased coils match furnaces without any overhang but require optional adaptor base or field fabricated transition to match furnace width. C35.5 to 5 Ton Indoor Coils / Page 3
4 SPECIFICATIONS 2.5 TO 4 TON General Data Uncased Model No. C35-30/36C-2 C35-36A-2 C35-36B-2 C35-48B-2 C35-48C-2 Line Connections in. Cased Model No. C35-30/36C-2F C35-36A-2F C35-36B-2F C35-48B-2F C35-48C-2F Nominal size - Tons 2.5 / / / 4 Suction / vapor o.d. - sweat 7/8 7/8 Liquid o.d. - sweat 3/8 3/8 3/8 3/8 3/8 Condensate drain (fpt) (2) (2) (2) (2) (2) RFCIV metering device orifice size Indoor Coil Matching Lennox Furnace - Cabinet Width Designation Net face area sq. ft Tube diameter - in. 3/8 3/8 3/8 3/8 3/8 Number of rows Fins per inch C A B B C Coil & Furnace Cabinet Width - in. 2 4-/2 7-/2 7-/2 2 Shipping Data - lbs. Uncased Cased Uncased coils match furnaces without any overhang but require optional adaptor base or field fabricated transition to match furnace width. SPECIFICATIONS 4 TO 5 TON General Data Uncased Model No. C35-49C-2 C35-50/60C-2 C35-60C-2 C35-60D-2 Line Connections in. Cased Model No. C35-49C-2F C35-50/60C-2F C35-60C-2F C35-60D-2F Nominal size - Tons 4 4 / Suction / vapor o.d. - sweat 7/8 7/8 7/8 7/8 Liquid o.d. - sweat 3/8 3/8 3/8 3/8 Condensate drain (fpt) (2) (2) (2) (2) RFCIV metering device orifice size Indoor Coil Matching Lennox Furnace - Cabinet Width Designation Net face area sq. ft Tube diameter - in. 3/8 3/8 3/8 3/8 Number of rows Fins per inch C C C D Coil & Furnace Cabinet Width - in /2 Shipping Data - lbs. Uncased Cased Uncased coils match furnaces without any overhang but require optional adaptor base or field fabricated transition to match furnace width. OPTIONAL ACCESSORIES - ORDER SEPARATELY Adjustable Coil Adaptor/Seal - Uncased models only (Ten Pack) L09 C35.5 to 5 Ton Indoor Coils / Page 4
5 AIR RESISTANCE Air Total Resistance Model Volume Dry Coil Wet Coil No. cfm in. w.g. in. w.g. C35-8/24A-2 C35-8/24B C35-24A C35-24B C35-30A C35-30B C35-30/36A C35-30/36B-2 C35-30/36C-2 C35-36B Model No. Air Total Resistance Volume Dry Coil Wet Coil cfm in. w.g. in. w.g. C35-36A C35-48B C35-48C C35-49C C35-50/60C C35-60D C35-60C C35.5 to 5 Ton Indoor Coils / Page 5
6 OPTIONAL ACCESSORIES - ADJUSTABLE UNCASED COIL ADAPTOR/SEAL C35-8/24A thru C35-60C UNCASED COILS C35-60D UNCASED COILS PLENUM ACCESS PANEL PLENUM ACCESS PANEL UNCASED COIL PIPING PATCH PLATE (Furnished with coil) ADJUSTABLE COIL ADAPTOR/SEAL (Optional for Uncased Coil) UNCASED COIL PIPING PATCH PLATE (Furnished with coil) ADJUSTABLE COIL ADAPTOR/SEAL (Optional for Uncased Coil) FURNACE FURNACE 2- (70) 4-/2 (368) to 24-7/8 (632) 9 (228) to 9-3/8 (492) Opening 2- (70) (9) (25) 9- (502) 7- (45) Opening (25) ADJUSTABLE COIL ADAPTOR/SEAL DETAIL Frame Telescopes To Accommodate Various Furnace Openings Tab Tab may be bent up 90 for centering of smaller coils. C35.5 to 5 Ton Indoor Coils / Page 6
7 DIMENSIONS - INCHES (MM) UNCASED COILS C35-8/24A, -8/24B, -24A, -24B Coils G F B SUCTION LINE -7/8 LIQUID LINE E -/2 CONDENSATE (38) DRAINS D /2 (3) AIR FLOW -7/8 C A -7/8 - (44) 2-/2 (64) 6 (406) 9-/2 (25) Model Number A B C D E F G in. mm in. mm in. mm in. mm in. mm in. mm in. mm C35-8/24A / / / / /8 98 C35-8/24B 5-/ / / / /8 92 C35-24A / / / / / C35-24B 5-/ / / / / C35-30A Coil 2-/2 (63) LIQUID LINE 20- (527) -/2 (38) -5/8 (4) 7-/2 (444) SUCTION LINE -7/8 CONDENSATE DRAINS 9-/2 (24) AIR FLOW /2 (3) -7/8 9-/4 (235) 3 (330) -7/8 - (44) 2-/2 (64) 6 (406) 9-/2 (25) C35.5 to 5 Ton Indoor Coils / Page 7
8 DIMENSIONS - INCHES (MM) UNCASED COILS C35-30B, -30/36A, -30/36B, -30/36C, -36A, -36B, -48B, -48C, -49C, -50/60C Coils G F B SUCTION LINE -7/8 AIR FLOW -/2 (38) LIQUID LINE CONDENSATE DRAINS E D /2 (3) -7/8 C A -7/8 - (44) 2-/2 (64) 6 (406) 9-/2 (25) Model A B C D E F G Number in. mm in. mm in. mm in. mm in. mm in. mm in. mm C35-30B 5-/ / / C35-30/36A / / / / /8 98 C35-30/36B 5-/ / / / C35-30/36C / / /8 60-7/ / C35-36A / / / / / /2 89 C35-36B 5-/ / / / /8 92 C35-48B 5-/ / /8 2-/4 3 3-/ C35-48C / / / / C35-49C 9-/ / /2 4 -/ / C35-50/60C / / / C35.5 to 5 Ton Indoor Coils / Page 8
9 DIMENSIONS - INCHES (MM) UNCASED COILS C35-60C Coil 4-/2 (4) LIQUID LINE 30-5/8 (778) -/2 (38) 2-5/8 (67) SUCTION LINE -7/8 CONDENSATE DRAINS 23-5/8 (600) 3- (349) AIR FLOW /2 (3) -7/8 5- (400) 9-/2-7/8 2-/2 (64) - (44) 6 (406) 9-/2 (25) C35-60D Coil 7/8 (22) 5/8 (6) LIQUID LINE -/2 (38) SUCTION LINE 8-7/8 (479) 28 (7) CONDENSATE DRAINS 4-/4 (362) /2 (3) -/2 (38) 9 (483) 23 (584) 2-/2 (64) 2-5/8 (67) 4-/4 (362) 9-/2 2-5/8 (67) C35.5 to 5 Ton Indoor Coils / Page 9
10 DIMENSIONS - INCHES (MM) CASED COIL C35-8/24(A/B), -30/36(A/B/C), -36(A/B) Coils (9) (9) C 9-/2 OUTLET (9) A (9) (9) TOP VIEW 2 (533) H SUCTION LINE LIQUID LINE -/2 (38) G -/4 (32) F E B AIR FLOW 9/6 (4) INLET 2-5/8 (67) D CONDENSATE 9/6 DRAINS (4) 20-7/6 (59) INLET 9/6 (4) Model Number A B C D E F G H in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm C35-8/24A-2F 4-/ / / / / /8 98 C35-8/24B-2F 7-/ / / / /8 98 C35-30/36A-2F 4-/ / / / /8 98 C35-30/36B-2F 7-/ / / / /8 08 C35-30/36C-2F / / / / /8 92 C35-36A-2F 4-/ / / / /4 83 C35-36B-2F 7-/ / / / /8 98 C35.5 to 5 Ton Indoor Coils / Page 0
11 DIMENSIONS - INCHES (MM) CASED COIL C35-24(A/B), -30(A/B), -48(B/C), -50/60C and -60D Coils (NOTE - See next page for C35-48C-2F and C35-60C-2F Coils) (9) (9) 9-/2 (9) NOTE- C35-60D coil is positioned in cabinet with coil running left to right, all other coil sizes are positioned like drawing. C OUTLET A (9) (9) TOP VIEW 2 (533) SUCTION LINE LIQUID LINE -/2 (38) H G -/4 (32) F E B AIR FLOW 9/6 (4) INLET 2-5/8 (67) D CONDENSATE 9/6 DRAINS (4) INLET 20-7/6 (59) 9/6 (4) Model Number A B C D E F G H in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm C35-24A-2F 4-/ / / / / /8 98 C35-24B-2F 7-/ / / / /8 98 C35-30A-2F 4-/ / / / /8 98 C35-30B-2F 7-/ / / / / /8 98 C35-48B-2F 7-/ / / / / C35-48C-2F / / / / /2 89 C35-50/60C-2F / / / / /2 89 C35-60D-2F 24-/ / / / /2 2-5/ /8 67 C35.5 to 5 Ton Indoor Coils / Page
12 DIMENSIONS - INCHES (MM) CASED COIL C35-49C-2F and C35-60C-2F (9) - (44) 9-/2 9-/2 OUTLET (9) (9) TOP VIEW 2 (533) (9) 22 (559) SUCTION LINE LIQUID LINE -/2 (38) D E -/4 (32) A B C AIR FLOW 9/6 (4) INLET 2-5/8 (67) 9-7/8 (505) 9/6 (4) CONDENSATE DRAINS 2-7/6 (545) INLET 9/6 (4) Model Number A B C D E in. mm in. mm in. mm in. mm in. mm C35-49C-2F / / / /2 64 C35-60C-2F / / / /2 64 C35.5 to 5 Ton Indoor Coils / Page 2
13 DIMENSIONS - INCHES (MM) - FURNACE/COIL COMBINED DIMENSIONS UPFLOW POSITION Model No C35 Cased C35 Uncased A B A B C35/CX35 in. mm in. mm in. mm in. mm C35/CX35-8/24A C35/CX35-8/24B C35/CX35-24A C35/CX35-24B C35/CX35-30A C35/CX35-30B C35/CX35-30/36A C35/CX35-30/36B C35/CX35-30/36C C35/CX35-36A C35/CX35-36B C35/CX35-48B C35/CX35-48C 6-/ / / / / / / / / / / / / / / / / / / / / / / / / / / / C35/CX35-49C 29-/ / / /2 562 C35/CX35-50/60C 27-/ / / / / / CX35-60C 3-/ / / /8 66 CX35-60D 29-/ / A 33 (838) B C35.5 to 5 Ton Indoor Coils / Page 3
14 C33 TO C35 UNCASED COIL CROSS-REFERENCE C33 Model No. Tons Dimensions (H x W x D) Order No. C35 Model No. Tons Dimensions (H x W x D) Order No. C33-8A x 3 x L32 C35-8/24A x 3 x F27 C33-24A x 3 x L33 C35-8/24A x 3 x F27 C33-24B x 5.5 x L37 C35-8/24B x 5.5 x F28, 2, 3 C33-24C x 20 x M25, 2, 3 C35-8/24B x 5.5 x F28 C33-9A x 3 x M07 C35-24A x 3 x F29 C33-25A x 3 x M08 C35-24A x 3 x F29 C33-25B x 5.5 x M09 C35-24B x 5.5 x F30 C33-3A x 3 x M0 C35-30A x 3 x F3 C33-3B x 5.5 x M C35-30B x 5.5 x F32 C33-30A x 3 x L34 C35-30/36A x 3 x F33 C33-36A x 3 x L35 C35-30/36A x 3 x F33 C33-30B x 5.5 x L38 C35-30/36B x 5.5 x F35 C33-36B x 5.5 x L39 C35-30/36B x 5.5 x F35 C33-30C x 20 x M26 C35-30/36C x 20 x F36 C33-36C x 20 x L43 C35-30/36C x 20 x F36 C33-38A x 3 x L36 C35-36A x 3 x F37 C33-38B x 5.5 x L40 C35-36B x 5.5 x F39 C33-42B x 5.5 x L4 C35-48B x 5.5 x F40 C33-43B x 5.5 x M2 C35-48B x 5.5 x F40 C33-48B x 5.5 x L42 C35-48B x 5.5 x F40 C33-43C x 20 x M3 C35-48C x 20 x F43 C33-44C x 20 x L44 C35-48C x 20 x F43, 2, 3 C33-48C x 20 x L45, 2, 3 C35-49C x 9.5 x F44 C33-49C x 9.5 x M4 C35-49C x 9.5 x F45 C33-50/60C x 20 x L46 C35-50/60C x 20 x F45 C33-62C x 9.5 x M5 C35-60C x 9.5 x F46 C33-60D x 23 x L47 C35-60D x 23 x F47 C33-62D x 23 x L48 C35-60D x 23 x F47 Coil heights do not match between C33 and C35 models. 2 Coil widths do not match between C33 and C35 models. 3 Coil depths do not match between C33 and C35 models. C35.5 to 5 Ton Indoor Coils / Page 4
15 C33 TO C35 CASED COIL CROSS-REFERENCE C33 Model No. Tons Dimensions (H x W x D) Order No. C35 Model No. Tons Dimensions (H x W x D) Order No. C33-8A-2F x 4.5 x 2 54M79 C35-8/24A-2F x 4.5 x 2 0C6 C33-24A-2F x 4.5 x 2 76L6 C35-8/24A-2F x 4.5 x 2 0C6 C33-24B-2F x 7.5 x 2 76L20 C35-8/24B-2F x 7.5 x 2 0C62 2 C33-24C-2F x 2 x 2 70M23 2 C35-8/24B-2F x 7.5 x 2 0C62 C33-9A-2F x 4.5 x 2 84M98 C35-24A-2F x 4.5 x 2 0C63 C33-25A-2F x 4.5 x 2 84M99 C35-24A-2F x 4.5 x 2 0C63 C33-25B-2F x 7.5 x 2 85M00 C35-24B-2F x 7.5 x 2 0C64 C33-3A-2F x 4.5 x 2 85M0 C35-30A-2F x 4.5 x 2 0C67 C33-3B-2F x 7.5 x 2 85M02 C35-30B-2F x 7.5 x 2 0C68 C33-30A-2F x 4.5 x 2 76L7 C35-30/36A-2F x 4.5 x 2 0C69 C33-36A-2F x 4.5 x 2 76L8 C35-30/36A-2F x 4.5 x 2 0C69 C33-30B-2F x 7.5 x 2 76L2 C35-30/36B-2F x 7.5 x 2 0C70 C33-36B-2F x 7.5 x 2 76L22 C35-30/36B-2F x 7.5 x 2 0C70 C33-30C-2F x 2 x 2 70M24 C35-30/36C-2F x 2 x 2 0C7 C33-36C-2F x 2 x 2 76L26 C35-30/36C-2F x 2 x 2 0C7 C33-38A-2F x 4.5 x 2 76L9 C35-36A-2F x 4.5 x 2 0C72 C33-38B-2F x 7.5 x 2 76L23 C35-36B-2F x 7.5 x 2 0C73 C33-42B-2F x 7.5 x 2 76L24 C35-48B-2F x 7.5 x 2 0C74 C33-43B-2F x 7.5 x 2 85M03 C35-48B-2F x 7.5 x 2 0C74 C33-48B-2F x 7.5 x 2 76L25 C35-48B-2F x 7.5 x 2 0C74 C33-43C-2F x 2 x 2 85M04 C35-48C-2F x 2 x 2 0C75 C33-44C-2F x 2 x 2 76L27 C35-48C-2F x 2 x 2 0C75 C33-48C-2F x 2 x 2 76L28 C35-49C-2F x 2 x 22 0C77 C33-49C-2F x 2 x 22 85M05 C35-49C-2F x 2 x 22 0C77 C33-50/60C-2F x 2 x 2 54M80 C35-50/60C-2F x 2 x 2 0C78 C33-62C-2F x 2 x 22 85M06 C35-60C-2F x 2 x 22 0C79 C33-60D-2F x 24.5 x 2 54M8 C35-60D-2F x 24.5 x 2 0C80 C33-62D-2F x 24.5 x 2 54M82 C35-60D-2F x 24.5 x 2 0C80 Coil heights do not match between C33 and C35 models. 2 Coil widths do not match between C33 and C35 models. 3 Coil depths do not match between C33 and C35 models.
16 REVISIONS Sections Document Description of Change Added C35 uncased models. Visit us at For the latest technical information, Contact us at LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 208 Lennox Industries, Inc.
1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS CX35 Upflow - Cased - R-40A PRODUCT SPECIFICATIONS Bulletin No. 0668 November 06 Supersedes September 05.5 to 5 Tons MODEL NUMBER IDENTIFICATION C X 35-36 A - 6 F Unit Type C = Indoor Coil
More information1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal
More information14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION
E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S 14ACX MERIT Series R-410A Bulletin 210475 October 2009 Supersedes March 2009 SEER up to 15.5 1.5 to 5 Tons Cooling Capacity - 17,700 to 58,000
More information14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION
E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S 14ACX MERIT Series R-410A Bulletin 210565 December 2010 Supersedes November 2010 SEER up to 15.5 1.5 to 5 Tons Cooling Capacity - 17,700 to 58,000
More informationMCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH
MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationMCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH
MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:
More informationMCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH
MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationHIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity
ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More informationMin. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,
ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) SXT+ Product Specifications HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Multi-Speed ECM Based Air Handler ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions... Airflow Data...6 Heat Kit Data... Wiring
More informationHIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT H4A4 DX 1400 Product Specifications HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1-phase, 60 Hz
More informationYour Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant
Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,
More informationSplit System Cooling Product & Performance Data
SS-PRC014-EN Split System Cooling Product & Performance Data 2TTA0030-072A 2½ 6 Tons PUB. NO. 22-1740-01-0702 (EN) General Features Split System Cooling Units... The Evolution Continues 2TTA0 split systems
More informationChilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers
Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens
More informationCPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A
CPH Series 7½- to 12½-Ton Self-Contained Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Packaged Heat Pump with R-410A Standard
More informationSplit System Cooling Product & Performance Data
SS-PRC009-EN Split System Cooling Product & Performance Data 2TTA2030-060A 2½ 5 Tons PUB. NO. 22-1735-01-0302 (EN) General Features Split System Cooling Units... The Evolution Continues 2TTA2 split systems
More informationProduct Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS
Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) Product Data the environmentally sound refrigerant Carrier s Air Conditioners with Puronr refrigerant provide
More informationDCC Commercial. Submittal Data Form Tons Packaged Air Conditioners
DCC Commercial Submittal Data Form 15-25 Tons Packaged Air Conditioners 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h Job Name
More informationSealed Enclosure Cooling Air Conditioners
SPECTRACOOL Compact Indoor INDUSTRY STANDARDS UL/cUL Listed; Type 12; File No. SA6453 for N17 UL/cUL Listed; Type 12, 3R, 4, 4X optional; File No. SA6453 and UR/cUR Recognized on select models for N16
More informationProduct Data HC2, HC3 HOT WATER COIL - CASED MULTIPOISE
HC2, HC3 HOT WATER COIL - CASED MULTIPOISE Fig.1 ModelHC2/HC3 Product Data A07331 The HydroPlust hydronic coil incorporates proven standards for reliable system operation and performance. The HC2 and HC3
More informationProduct Data PH16NA FEATURES / BENEFITS. 16 SEER 2---Stage Split---System Heat Pump With R---410A Refrigerant 2 To 5 Tons ( ) AVAILABLE SIZES:
16 SEER 2---Stage Split---tem Heat Pump With R---410A Refrigerant 2 To 5 Tons (024---060) Product Data NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI
More informationV0STAT51P-2 Programmable Wired Controller
PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF V0STAT51P-2 Programmable Wired Controller Bulletin No. 210766 March 2016 Grouping - Controller can control up to 16 indoor units on the same
More informationSpecification. Radiamatic Detectors and Accessories
4/92 Page 1 of 8 Radiamatic Detectors and Accessories Specification Function The Radiamatic temperature detector generates an emf proportional to the temperature of the object sighted. It is used with
More informationIT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw
IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable
More informationHIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER
HVH8 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUP WITH OBSERVER COUNICATING CONTROL SYSTE 2 THRU 5 TONS SPLIT SYSTE 208 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Variable
More informationHoshizaki America, Inc.
Hoshizaki America, Inc. Low-Profile Modular Crescent Cuber Models KML-351MAH KML-351MWH A Superior Degree of Reliability PARTS LIST www.hoshizaki.com Number: 71267 Issued: 5-9-2008 Revised: 10-13-2014
More informationCabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan
DCH Series Submittal Data Form 7½ - 12½ Ton Packaged Heat Pump Up to 11.5 EER & 3.4 COP Cooling Capacity: 90,000 140,000 BTU/h Heating Capacity: 90,000 142,000 BTU/h Job Name Purchaser Order No. Engineer
More informationJ&M Fluidics, Inc. Company Product Overview
It s All about Building a Better Product for Our Clients! J&M Fluidics, Inc. Company Product Overview J&M Fluidics, Manufacturer of Air & Water-Cooled Process Chillers. Located in Telford, Pennsylvania
More informationACFD12-T ACFD12-B. Technical Data
TM ACFD12-T ACFD12-B Technical Data Contents Overview.................................................1 Scalable Solution for Critical Environments....................2 Standard Features.........................................5
More informationContents. Cabinet Components " Exploded View... 1 " Usage List U.S. Models... 2 " Usage List Canadian Models... 3 " Blank Page...
Replacement Parts Manual WAG SERIES COMBINATION GAS / ELECTRICS Models: WAG30D WAG36D WAG40D General Notes! Revised and/or additional pages may be issued from time to time.! A complete and current manual
More informationProduct Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound
24VNA9 Infinityr 19VS Variable Air Conditioner with Puronr Refrigerant 2 --- 5 Ton Product Data The Infinity 19VS air conditioner offers high -efficiency variable speed performance in a remarkably small
More informationDAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology
PRODUCT SPECIFICATIONS AIR CONDITIONERS SL18XC1 DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology Bulletin 210723 November 2017 Supersedes August 2017 SEER up to 18.50 2 to 5 Tons Cooling
More informationDCG Commercial. Submittal Data Form
DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons
More informationGP SERIES Packaged Chillers
Blending Conveying Drying Process Cooling Heat Transfer Size Reduction GP SERIES Packaged Chillers Comprehensive Flexible Versatile Compact unitary designs available in a variety of configurations from
More informationSpecification and Design Catalog. Waterside Economizer
Specification and Design Catalog Waterside Economizer Table of Contents Waterside Economizer Applications.................................................... 4 Application Notes..................................................................
More informationREPORT CBEI REPORT. Funded by U.S. DOE. Title: Virtual RTU Sensing Automation, Demonstration, and Assessment. Report Date: April 30, 2016
REPORT Title: Virtual RTU Sensing Automation, Demonstration, and Assessment Report Date: April 30, 2016 Report Authors: Akash Patil, Andrew L. Hjortland, James E. Braun Funded by U.S. DOE CBEI REPORT REPORT
More informationCONDENSING UNITS UASL- JEC
FORM NO. A22-196 3 Supersedes Form No. A22-196 Rev. 2 CONDENSING UNITS Equipped with Comfort Control 2 System Serial communication enabled Increased system reliability and efficiency 32+ on-board diagnostic
More informationDTH Series. Submittal Data Form. 3-5 Tons Heat Pumps 15 SEER Up to 13.0 EER / 8.2 HSPF
DTH Series Submittal Data Form 3-5 Tons Heat Pumps 15 SEER Up to 13.0 EER / 8.2 HSPF Cooling Capacity: 35,000 60,000 BTU/h Heating Capacity: 32,800 55,500 BTU/h Purchaser Order No. Engineer Unit No. Model
More informationChiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw
Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote
More informationModels: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA182, WA242 General Notes Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual consists
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationRheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control System
16.0 Air Air Conditioners Rheem Prestige Series Two- Air Conditioners equipped with the Comfort Control System Efficiencies up to 16.5 SEER/13.0 EER Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kw] Cooling Capacities
More informationTECHNICAL GUIDE ACCLIMATE TM SERIES SPLIT-SYSTEM HEAT PUMPS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: HL8B024 THRU 060
TECHNICAL GUIDE ACCLIMATE TM SERIES SPLIT-SYSTEM HEAT PUMPS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: HL8B024 THRU 060 Due to continuous product improvement, specifications are subject to change
More informationType. Facts. 441, 442 Full nozzle DIN. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E
Type 441, 442 DIN Flanged Safety Relief Valves spring loaded Metric Units Facts The-Safety-Valve.com LWN 468.01-E DIN, ANSI 40 Cap H2 19 Lock nut 18 Adjusting screw with bushing 16 Upper spring plate 12
More informationDaikin McQuay. Enfinity Water Source Heat Pump Ceiling Mounted. WCCH, WCCW 072, 096, 120 Design 1
Replacement Parts List No. 700017500 Revision C 10/2015 Daikin McQuay Enfinity Water Source Heat Pump Ceiling Mounted WCCH, WCCW 072, 096, 120 Design 1 To find your Daikin Applied parts distributor, call
More informationRheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control 2. System. RASL- JEC Series
16.0 Air Air Conditioners Rheem Prestige Series Two- Air Conditioners equipped with the Comfort Control 2 System Efficiencies up to 18 /14 Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kw] Cooling Capacities
More informationSlim duct (AMTTTFNLDEH ) Indoor units
Slim duct (AMTTTFNLDEH ) Slim duct. Specifications 1) Technical specifications Model AM22FNLDEH AM28FNLDEH AMFNLDEH AM4FNLDEH AMFNLDEH Power Supply Ø, #, V, Hz 1,2,22-24, 1,2,22-24, 1,2,22-24, 1,2,22-24,
More informationRuud Achiever Series Heat Pump
Heat Pumps Ruud Achiever Series Heat Pump RP14**F Series Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper
More informationCTC Low Temperature Process Chillers
INNOVATE DESIGN APPLY CTC Low Temperature Process Chillers 5-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough When it comes to process cooling, every application is unique in
More informationBrasch Washdown Unit Heaters
Brasch Washdown Unit Heaters Standard Features: Up to 48 KW Up to 400 Volts Disconnect switch with enclosure interlock Heavy-duty 304 stainless steel shroud Nema 4x non-metallic control panel 24-volt
More informationRosemount 1595 Conditioning Orifice Plate
Reference Manual Rosemount 1595 Conditioning Orifice Plate www.rosemount.com Reference Manual 00809-0100-4828, Rev BA Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate NOTICE Read this manual before
More informationXTREME ICE MAKER (1230 SERIES)
Anoka, MN. 0 Telephone -00--00 Facsimile -00--0 XTREME ICE MAKER (0 SERIES) MODEL NO. 00 00 00 00 00 00 0 Distributed By: Commercial Refrigeration Service, Inc. http://www.corneliusparts.com http://www.icecubes.net
More informationLINE UP LINE UP (RT) ( RCUP75AUZ / 50Hz ) Products Series RCUP-AUZ
Hitachi screw chiller unit widely used for air conditioning and industrial purposes Newly released, equipped with a new screw compressor realizing drastic energy saving and great functionality ( RCUP75AUZ
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14 SEER/11.5 EER 8.2 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationWALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA181, WA241. Contents. General Notes. Important
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA181, WA241 General Notes Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual consists
More informationDevelopment and Evaluation of an Automated Virtual Refrigerant Charge Sensor Training Kit
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 Development and Evaluation of an Automated Virtual Refrigerant Charge Sensor
More informationInstallation, Operation
Installation, Operation and RENEWAL PARTS IDENTIFICATION 4 (Supersedes PN400-2) MAY, 1986 Type RST and RSTO Unitary Electric Immersion Heaters RST PN400-3 161-049178-001 3 Schedule 40 Steel Pipe Immersed
More informationDIP. Spare parts list. Centrifugal pumps 25, 25-US, 35, 35-US, 65, 65-US Atlas Copco Construction Tools AB No c
DIP 5, 5US, 35, 35US, 65, 65US Spare parts list Centrifugal pumps 0 Atlas Copco Construction Tools AB No. 9800 5 0c 003 DIP 5, 5US, 35, 35US, 65, 65US Contents Contents General information................................................................
More informationSTANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request
PRODUCT DATA & SPECIFICATIONS Bulletin B40-BC-PDS Part # 1106712 PRODUCT SUPPORT web: b-rp.ca/bc email: multicompcu@b-rp.ca call: 1-844-893-3222 x524 scan: BC Combination Condensing Units Cooler/Freezer
More informationWO P-NF-L-M-407c Spec Submittal
WO2-2-10000-2P-NF-L-M-407c Spec Submittal General Specifications WO2-2-10000(801304) Width: IN/CM 136.25/346.07 Height: IN/CM 84.5/214.63 Depth: IN/CM 41.7/105.92 Dry weight: LB/KG 4000/1814.37 Operational
More informationSlim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL
E5-3I D-AP 4SP2U Slim Ducted type D-AP0074SP2U D-AP0094SP2U D-AP024SP2U D-AP054SP2U D-AP084SP2U Contents. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring diagram 6. Electrical
More informationMission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire
Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices
More informationINSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST
INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST MODEL WGSEIFM-5 For Use with Bard 3 through 5 Ton Step Capacity Wall Mount Air Conditioners with Gas Heat Bard Manufacturing Company, Inc. Bryan, Ohio
More informationTECHNICAL GUIDE. Technical Guide AFFINITY SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: HL6B 024 THRU 060
TECHNICAL GUIDE Technical Guide AFFINITY SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: HL6B 024 THRU 060 Due to continuous product improvement, specifications are subject
More informationMLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers
INNOVATE DESIGN APPLY www.motivaircorp.com MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough
More informationDaikin McQuay. Incremental Comfort System. PKEI, PKES, PKHS 007, 009, 012, 014 Design 2. Replacement Parts List No Revision G 12/2013
Replacement Parts List No. 700017400 Revision G 12/2013 Daikin McQuay Incremental Comfort System PKEI, PKES, PKHS 007, 009, 012, 014 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationKLP. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION
PRODUCT DATA & INSTALLATION Bulletin K30-KLP-PDI-16 Part # 1087150 PRODUCT SUPPORT web: k-rp.com/klp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: KLP Low Profile Evaporators Air, Electric, Hot
More informationFeatures: Quality Testing and Documentation
1 The Yokogawa Falcon Series Dual Chamber Orifice Assembly YFOM-DC, is suitably designed for on-line retraction and inspection of orifice plates in process full flow and pressure conditions. The orifice
More informationProduct Data. SYNERGY TDA (60 Hz) Two-Speed Electric Air Conditioner. Sizes 036, 048, and 060 FEATURES/BENEFITS
Product Data SYNERGY 2000 38 TDA (60 Hz) Two-Speed Electric Air Conditioner Sizes 036, 048, and 060 Model 38TDA Air Conditioners incorporate innovative 2-speed compressor technology to provide quiet, efficient
More information09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD
Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,
More informationModel VDL 115 Vacuum drying chambers for flammable solvents
Model VDL 115 Vacuum drying chambers for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber
More informationModeling of Compressors and Expansion Devices With Two-Phase Refrigerant Inlet Conditions
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Modeling of Compressors and Expansion Devices With Two-Phase Refrigerant
More informationCOMFORT CONTROL CENTER SERVICE INSTRUCTIONS
USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center
More informationAiretool Condenser Expanders Selection Guide G-900 Series Heat Exchanger and Condenser Tube Expanders. Airetool Heat Exchanger Condenser Expanders
Airetool Heat Exchanger Condenser Expanders Step Rolling Step rolling is required when expanding tubes in thick tube sheets. Typically the first expansion is made at the innermost location, away from the
More informationMotivair MLC-SC Air-Cooled Scroll Chillers Tons
INNOVATE DESIGN APPLY www.motivaircorp.com Motivair MLC-SC Air-Cooled Scroll Chillers 100 285 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Businesses who function in today s advanced
More informationCustomer Responsibilities
For Research Use Only. Not for use in diagnostic procedures. Thank you for purchasing the Agilent G5590A BenchCel Workstation. To get you started and to assure a successful and timely installation, please
More informationAssembly and Maintenance
Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines
More informationVEHICLE SPECIFIC PARTS BUSES. Buses. School & Transit PAGE 585
Vehicle Specific Buses School & Transit PAGE 585 Water Valve Rotary Actuator 72R6540 RD-5-9415-0P Red Dot Model R-6120 Gillig Bus, R-6135 Orion Bus Gillig Models 21-43550, 21-55565 Orion Models 071320036,
More informationDAIKIN GAS TIGHT JOINT (DGT)
LINE UP Model Name Size (mm) DAIKIN GAS TIGHT JOINT (DGT) SPECIFICATIONS BDGTA06 ø 6.4 BDGTA06 ø 9.5 BDGTA12 ø 12.7 BDGTA15 ø 15.9 BDGTA19 ø 19.1 BDGTA22 ø 22.2 BDGTA28 ø 28.6 DAIKIN GAS TIGHT JOINT Applicable
More informationglide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA
99 glide air cooled liquid chillers ND free cooling chillers glider 178 1328 Energy Class More efficient + B C D E F G Less efficient R134a CLSS SHELL C E C FREE COOLING 100 air cooled liquid chiller and
More informationDIRECT DRIVE VANEAXIAL FIXED PITCH FANS
DIRECT DRIVE VANEAXIAL FIXED PITCH FANS BULLETIN 6 DECEMBER 201 Capacities to 100,000 Static pressures to WG Temperatures to 10 F. THE NEW YORK BLOWER COMPANY 660 Quincy Street Willowbrook, IL 602-0 Visit
More informationProduct Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS
Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) the environmentally sound refrigerant Carrier s heat pumps with Puronr refrigerant provide a collection of features
More informationDCG Series. Submittal Data Form. 3-6 Ton Packaged Gas/ Electric Units 13 SEER / up to 11.3 EER / 80% AFUE
Submittal Data Form Job Name DCG Series 3-6 Ton Packaged Gas/ Electric Units 13 SEER / up to 11.3 EER / 80% AFUE 6-Ton with Two-Speed Blower Motor and Two-Stage Compressor Up to 15.5 IEER Cooling Capacity:
More informationCTXA-AS/AT/AW, FTXA-AS/AT/AW
Split Air Conditioning Technical Data CTXA-AS/AT/AW, FTXA-AS/AT/AW > CTXAA2V1BS > CTXAA2V1BT > CTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT > FTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT > FTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT
More informationApplication Manual. Shark. Software for the simulation of refrigeration equipment and air conditioners
Page 1 of 184 Software for the simulation of refrigeration equipment and air conditioners Index Software for the simulation of refrigeration equipment and air conditioners... 1 : application description
More informationThe 5400A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel.
Varec 00A Series The 00A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel. Introduction Varec s have been the industry standard for over
More informationFeatured Products - RU Marking Standard on Hoffman brand
: Open Frame Racks CHAPTER Open frame racks are versatile solutions for mounting hubs, switches, routers and servers. Easy access to all sides simplifies maintenance and updates. Solidly constructed, Pentair
More informationWhat Could Possibly Go Wrong? A Laboratory Investigation of In-Field and Onboard FDD on a 5 Ton RTU
What Could Possibly Go Wrong? A Laboratory Investigation of In-Field and Onboard FDD on a 5 Ton RTU 2014 ET Summit New Packaged HVAC System Sensors, Logic and Communications Tons of Potential October 21,
More informationkyalfa V- VDD/VDD6 General Contents
General Contents. kyalfa V- VDD/VDD6 ky General Contents General Features A dry cooler is a forced convection air-cooled fluid cooler, designed for outdoor installation. Air is forced over the finned coil
More informationDUKE UNIVERSITY CONSTRUCTION STANDARDS
1 00 01 10 Table of Contents DIVISION 00: PROCUREMENT AND CONTRACTING REQUIREMENTS 00 01 10 Table of Contents 06.17.2014 00 21 13 Instructions to Bidders 11.08.2013 00 22 13 Supplementary Instructions
More informationshop online:
Process systems Liquid ring vacuum pumps Single stage pumps 8 Alpha series single stage liquid ring vacuum pumps 9 AL series single stage liquid ring vacuum pumps 97 Two stage pumps 00 SHR series liquid
More informationAmerican Society of Sanitary Engineering Seal (Certification) Program
American Society of Sanitary Engineering Seal (Certification) Program Laboratory Evaluation Report for: Water Hammer Arresters Tested under ASSE Standard 1010 Revised: February, 2004 Laboratory File Number
More informationSelf-Contained Air Conditioning Systems
Self-Contained Air Conditioning Systems 20 to 130 tons Proven Applications Testimonials Daikin is an industry leading manufacturer of self-contained air conditioning products. Ideal for jobs where energy
More informationDDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear
I TECHNICAL SPECIFICATIONS ROAD BUILDING DDDM 45 (40-60 TPH) DOUBLE DRUM ASPHALT PLANT - DDDM 50 (60-90 TPH) DDDM 60 (90-120 TPH) COLD AGGREGATE FEEDER Stationary four bin cold aggregate feeder unit is
More informationPrecision Cooling Mission Critical Air Handling Units
M I S S I O N C R I T I CA L C O O L I N G Precision Cooling Mission Critical Air Handling Units Global Expertise for Precision Cooling Solutions STULZ is a privately owned, global manufacturer of highly
More informationAIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS
PAH 2802 T K AIR R-407C R-134a Series PAH... T K from 205 to 778 kw - 2 circuits The air cooled heat pumps of PAH.T series are designed for outdoor installation and are particularly suitable for industrial
More informationBOARD LEVEL POWER SEMICONDUCTOR HEAT SINKS
217 SERIES Surface Mount D 2 PAK,, SOT-223, SOL-2 Compatible with surface mount technology (SMT) automated production techniques for ease of assembly and a variety of soldering methods, these heat sinks
More informationThermal Diffusivity Instruments DLF-2 with EM-1600
Thermal Diffusivity Instruments DLF-2 with EM-1600 Site Preparation Guide Revision A Issued February 2017 Table of Contents Table of Contents... 1 Ideal Setup... 2-3 System Components... 3 Instrument Measurements...
More information42C/V. Fan Coil Unit Air Flow: 340~2040m 3 /h
2/V Fan oil Unit Air Flow: 0~0m 3 /h arrier hina arrier orporation is a subsidiary of the United Technologies orp. (UT), which ranks the 10th in Fortune Top 00 in and has its operations in aerospace and
More informationVAREC 5000/5010 SERIES FLAME ARRESTERS
VAREC 000/00 SERIES FLAME ARRESTERS Group D end-of-line flame arresters with a unique extensible bank frame designed to stop the propagation of flame from external sources FEATURES 00 SERIES - HORIZONTAL
More information