June 1, 2017 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA

Size: px
Start display at page:

Download "June 1, 2017 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA"

Transcription

1 June 1, 2017 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA REVISED AMENDMENT NO.3/ CONTRACT NO. Y TERM CONTRACT FOR COUNTY WIDE ROOF MAINTENANCE AND REPAIR ADVANCED ROOFING, INC. 200 Northstar Court Sanford, Florida This amendment is hereby incorporated into the contract documents of the project referenced above. The following items are clarifications, corrections, additions, deletions and/or revisions to and shall take precedence over the original documents. Additions are indicated by underlining, deletions are indicated by strikethrough. 1. This Contract Amendment is issued to correct the effective dates of Amendment No.1 that extends the term of the contract. 2. In accordance with General Conditions Article 26, Option to Extend the Term of the Contract. the County exercises Option No. 1 by extending the term of the contract as follows: From: June 6, 2016 through June 5, 2017 To: June 6, 2017 through June 5, 2018 Option Year No.1 prices will become effective on June 6, All other terms, conditions and specifications remain the same. Board of County Commissioners Orange County, Fl Elia R. Batista Senior Contract Administrator Procurement Division Date

2 April 4, 2017 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA AMENDMENT NO. 2 /CONTRACT NO. YlG ~- ' ~ """r,.,._~.._,.. _. ' - '. ;t / TERM CONTRACT FOR COUNTY WIDE ROOF MAINTENANCE AND REPAIR ADVANCED ROOFING, INC. 200 Northstar Court Sanford, Florida EFFECTIVE DATE: April4, 2017 This amendment is hereby incorporated into the contract documents of the project referenced above. The following items are clarifications, corrections, additions, deletions and/or revisions to and shall take precedence over the original documents. Additions are indicated by underlining, deletions are indicated by strikethrough. In accordance with Florida's Public Records Law, Chapter 119, Florida Statutes the following Article 37, Public Records Compliance (Applicable for Service Contracts) is hereby added to Part F, the General Conditions of the contract: ARTICLE 37 -PUBLIC RECORDS COMPLIANCE (APPLICABLE FOR SERVICE CONTRACTS) Orange County is a public agency subject to Chapter 119, Florida Statutes. The Contractor agrees to comply with Florida's Public Records Law. Specifically, the Contractor shall: 1. Keep and maintain public records required by Orange County to perform the service. 2. Upon request from Orange County's custodian of public records, provide Orange County with a copy of the requested records or allow the records to be inspected or copied within a reasonable time at a cost that does not exceed the cost provided in this chapter or as otherwise provided by law. 3. Ensure that public records that are exempt or confidential and exempt from the public records disclosure requirements are not disclosed except as authorized by law for the duration of the contract term and following completion of the contract if the Contractor does not transfer the records to Orange County. 4. Upon completion of the contract, Contractor agrees to transfer at no cost to Orange County all public records in possession of the Contractor or keep and maintain public records required by Orange County to perform the service. If the Contractor transfers all public record to Orange County upon completion of the contract, the Contractor shall destroy any duplicate public records that are exempt or confidential and exempt from public records disclosure requirements. If the Contractor keeps and maintains public records upon completion of the contract, the Contractor shall meet all applicable requirements for retaining public Contract No. Yl6-182 Amendment #2 April 4, 2017 Page 1

3 c March 17, 2017 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA AMENDMENT NO. 1 I CONTRACT NO. Y TERM CONTRACT FOR COUNTY WIDE ROOF MAINTENANCE AND REPAIR ADVANCED ROOFING, INC. 200 Northstar Court Sanford, Florida This amendment is hereby incorporated into the contract documents of the project referenced above. The following items are clarifications, corrections, additions, deletions and/or revisions to and shall take precedence over the original documents. Additions are indicated by underlining, deletions are indicated by strikethrough. 1. In accordance with General Conditions Article 26, Option to Extend the Term of the Contract, the County exercises Option No. 1 by extending the term of the contract as follows: From: June 3, 2016 through June 2, 2017 To: June 3, 2017 through June 2, 2018 Option Year No.1 prices will become effective on June 3, All other terms, conditions and specifications remain the same. Board of County Commissioners Orange County, FL Elia R. Batista Senior Contract Administrator Procurement Division -::2/. -J J ' -~ <~J,:;) -~~; I -f I ' Date

4 records. All records stored electronically must be provided to Orange County, upon request from Orange County's custodian of public records, in a format that is compatible with the information technology systems of Orange County. 5. A Contractor who fails to provide the public records to Orange County within a reasonable time may be subject to penalties under section , Florida Statutes. 6. IF THE CONTRACTOR HAS QUESTIONS REGARDING THE APPLICATION OF CHAPTER 119, FlORIDA STATUTES, TO THE CONTRACTOR'S DUTY TO PROVIDE PUBLIC RECORDS RElATING TO THIS CONTRACT, CONTACT THE CUSTODIAN OF PUBLIC RECORDS AT: Procurement Public Records liaison 400 E. South Street, 2"d Floor, Orlando, Fl ProcurementRecords@ocfl.net Board of County Commissioners Orange County, FL Elia R. Batista, Sr. Contract Administrator Procurement Division 4-/-+ tl1 Date Contract No. Yl6-182 Amendment #2 April 4, 2017 Page 2

5

6

7

8

9

10 Y EB REVISED BID ITEM SCHEDULE BASE YEAR METAL ROOFING - REPAIR AND REPLACEMENT DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED LINE UNIT PRICE REFERENCE MEASURE QTY TOTAL # DETAILED DESCRIPTION 1 Metal roofing replacement (Maximum 10,000 SF) SPECS: SF 5,000 Detail: G Series , SPECS: Detail: G.1 04, G.304 & G , Metal roof ridqe closure repair LF 3,500 SPECS: Detail: G.602 & G Metal roof penetration boot flashina replacement EA 5 Clean existing metal panel roof using soft wash and chemical solutions to remove stainina. SPECS: SF 2,500 SHINGLES - REPAIR AND REPLACEMENT LINE # DETAILED DESCRIPTION DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE REFERENCE MEASURE QTY TOTAL 3-Tab Asphalt Shingle Roofing- 5 Gable Roofs (Maximum 5 10,000 SF) SF 5,000 - SPECS: , Revised Page D-1 I Y EB I Addendum No.3

11 SPECS: Architectural Shingle Roofing - 5 Hip Roofs (Maximum 6 10,000 SF) SF 25, , SPECS: Laminated Asphalt Shingle Roofing - low slope roof with 7 self-adhesive SF 3, , B.U.R. REPAIR AND REPLACEMENT LINE # DETAILED DESCRIPTION DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE REFERENCE MEASURE QTY TOTAL 8 Build-up asphalt roofing replacement (Maximum 10,000 SPECS: SF 5,000 SF) Details: B-Series , I 9 BUR-Edge Repair SPECS: LF Detail: B1.01 & B.102 SPECS: BUR-Base Flashing Repair with Coating LF 15 Detail: B B SPECS: BUR-Install Roof Drain Insert and Flashing -Type 4" dia EA 5 Detail: B.701 & B , I ' SPECS: BUR-Pitch Pan Repair EA 5 Detail: B SPECS: BUR-Replace Pitch Pan- Type 8" x 8" EA , Detail: B.604 Revised Page D-2 I Y EB I Addendum No.3

12 SPECS: BUR-Cut and Patch Holes, Blisters and Ridges SF 250 Detail: B SINGLE-PLY- REPAIR AND REPLACEMENT DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED LINE UNIT PRICE REFERENCE MEASURE QTY TOTAL # DETAILED DESCRIPTION 15 Thermoplastic single-ply roofing replacement (Maximum SPECS: SF 30,000 10,000 SF) Details: D-Series , SPECS: Single-Ply- Replace Plumbing Stack or Pipe Flashing EA 5 Detail: D SPECS: Single-Ply- Repair Base Flashing LF 350 Detail: D.201-D , SPECS: Single-Ply- Install 3" dia roof drain Insert and Flashing EA Detail: D.201-D.205 2, SPECS: Expansion joint repair LF 50 Detail: D.401-D " x 6" patch of 45 mil membrane heat-welded to existing SPECS: EA membrane , Patch of 45 mil membrane heat-welded to existing SPECS: SF 2, , membrane Revised Page D-3 I Y EB I Addendum No.3

13 ~~~- ~ -- - Installation of aluminum roof drain inserts into existing 4" 22 dia. roof drains, w/single-ly membrane fully adhered as specified SPECS: EA , Replacement of sealant along the top of existing SPECS: LF 1,000 termination bar I 24 Cleaning of existing roof membrane using soft wash and chemical solutions to remove staining. SPECS: SF I i MODIFIED BITUMEN - REPAIR AND REPLACEMENT DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED LINE UNIT PRICE REFERENCE MEASURE QTY TOTAL # DETAILED DESCRIPTION I I i 25 Modified Bitumen (2-ply) roofing replacement (Maximum SPECS: ,000 SF) Details: C-Series SF 5, , Modified Bitumen - Repair Plumbing Stack Flashing SPECS: Detail: C.601 EA Modified Bitumen - Pitch Pan Repair SPECS: Detail: C.604 EA Modified Bitumen - Replace Pitch Pan - Type 8" x 8" SPECS: EA Modified Bitumen - Repair Base Flashing SPECS: Detail: C.202-C.206 LF Modified Bitumen - Cut and Patch Blisters and Ridges SPECS: Detail: C.201 SF 3, , ~- -~-~ '~~ --~ - - ~ ---- Revised Page D-4 I Y EB I Addendum No.3

14 31 Modified Bitumen - Install 4" dia. Roof Drain Insert and SPECS: Flashing Detail: C.701 EA , Expansion joint repair SPECS: LF Detail: C.401-C Repair of Bituminous sheet base flashing repair with aluminized coating. SPECS: LF Replacement of sealant along metal counter flashing termination. SPECS: LF Overflow scupper flashing repair. SPECS: Detail: H.714& H.715 EA , Cleaning of existing roof membrane using soft wash and chemical solutions to remove staining. SPECS: SF COATING LINE # DETAILED DESCRIPTION DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE REFERENCE MEASURE QTY TOTAL SPECS: Coating- BUR or Modified Bitumen SF 1, , SPECS: Coating - Sin~le-Piy SF 15, , Revised Page D-5 I Y EB I Addendum No.3

15 SPECS: Coatir_:19_- EPDM SF , LIGHTNING PROTECTION LINE # DETAILED DESCRIPTION DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE REFERENCE MEASURE QTY TOTAL 40 Provide copper conductor cable, including associated fittings and couplings. Minimum 100 LF. SPECS: LF 2, , Provide aluminum conductor cable, including associated fittings and couplings. Minimum 100 LF. SPECS: LF 2, , Provide aluminum threaded air terminal, 1/2" diameter, 10" 18" in length. SPECS: EA , Provide aluminum threaded air terminal, 1/2" diameter, 24" 48" in length. Provide aluminum threaded air terminal, 5/8" diameter, 10" 18" in length. SPECS: EA , SPECS: EA , Provide aluminum threaded air terminal, 5/8" diameter, 24" 48" in length. SPECS: EA , Provide copper threaded air terminal, 1/2" diameter, 10"- 18" in length. SPECS: EA , Provide copper threaded air terminal, 1/2" diameter, 24"- 48" in length. SPECS: EA , Revised Page D-6 I Y EB I Addendum No.3

16 48 Provide copper threaded air terminal, 5/8" diameter, 10"- 18" in length. SPECS: EA , Provide copper threaded air terminal, 5/8" diameter, 24" - 48" in length. SPECS: EA , Provide aluminum air terminal base for use on horizontal surfaces (adhesive mount). SPECS: EA , Provide cast bronze air terminal base for use on horizontal surfaces (adhesive mount). SPECS: EA , Provide aluminum air terminal base for use on vertical surfaces (mechanical mount). SPECS: EA , Provide cast bronze air terminal base for use on vertical surfaces (mechanical mount). SPECS: EA , Provide aluminum air terminal base for use on standing seam metal roofing (clamp-on mount). SPECS: EA , Provide cast bronze air terminal base for use on standing seam metal roofing (clamp-on mount). SPECS: EA , Provide aluminum cable mount for use on standing seam metal roofing (clamp-on mount). SPECS: EA , Provide cast bronze cable mount for use on standing seam metal roofing (clamp-on mount). SPECS: EA , Provide aluminum air terminal base for mounting on pipes (clamp-on mount). SPECS: EA , Revised Page D-7 I EB I Addendum No.3

17 59 Provide cast bronze air terminal base for mounting on pipes (clamp-on mount). SPECS: EA , Test lightning protection system after roof work is complete. SPECS: EA , Provide U.L. Master Label for system once completed. 61 Assume new system, or existing system had Master Label SPECS: EA 50 previously , Provide plastic isolating sleeves for cables where dissimilar 62 metals come in contact with one another. (i.e. copper SPECS: EA cable extending over galvanized or aluminum edge metal) Provide 3/4" diameter by 20' long, copper clad steel grounding rods. Grounding rods can be 10' in length with exothermic-fusion-welded sections to make required length. SPECS: EA , Reinstallation of the existing lightning protection cable clip or air terminal base to the roof surface. SPECS: EA MISCELLANEOUS LINE # DETAILED DESCRIPTION DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE REFERENCE MEASURE QTY TOTAL 65 Remove and dispose of metal gutter assembly, including hangars, straps, and fasteners. SPECS: LF , Remove and dispose of metal downspouts, including hangars, straps, and fasteners. SPECS: LF , Revised Page D-8 I Y EB I Addendum No.3

18 Install stainless steel gutter assembly, 5" X 6" average. Include metal gutter hangars and straps as detailed. 67 Solder joints in the gutter assembly. Provide expansion SPECS: LF 500 joints within the gutter assembly at maximum 40-ft intervals. Provide positive slope for gutters to drain , Install stainless steel "K" style gutter assembly, 5" X 6" average. Include metal gutter hangars and straps as 68 detailed. Solder joints in the gutter assembly. Provide SPECS: LF 500 expansion joints within the gutter assembly at maximum 40-ft intervals. Provide positive slope for gutters to drain , Provide stainless steel downspout, 4" x 5 average". SPECS: LF , Provide aluminum downspout, 4" x 5" average- with baked on enamel finish. SPECS: LF , Remove and replace existing plywood soffit at eave 71 locations. Assume up to 3' Eave, 5/8" COX plywood. SPECS: SF 500 Include fasteners and trim , Remove and replace existing vented vinyl soffit at eave 72 locations. Assume up to 3' Eave. Include fasteners and SPECS: SF , trim. Remove and replace existing vented aluminum soffit at 73 eave locations. Assume up to 3' eave, with baked on color SPECS: SF , coating. Include fasteners and trim. I Provide for 2" nominal thickness wood framing repairs at 74 rafter tail, fascia and eave locations. Include fasteners and SPECS: LF 2,000! metal connectors for securement of reinforcing members , I I I I I Revised Page D-9 I Y EB I Addendum No. 3

19 75 1/2-inch CDX Plywood Deck SPECS: SF 2, , Temporary roof repair- Tarp with securement (various types of roofs) SF 1, , Emergency Response (<4 hrs) Surcharge. This surcharge is only applicable to emergency repairs. 77 Estimated Amount: 300, of emergency work for.50 LS % 1, basic year, times(_%), equals emergency response 300,000 lump sum. Example 1% x 300,000 = 3, Trip Charge (Small Scale Repairs under 250 total) as specified. EA , TOTAL ESTIMATED BASE YEAR ITEMS 1 THROUGH , I I Revised Page D-10 I EB I Addendum No.3

20 Y EB BID ITEM SCHEDULE OPTION YEAR 1 METAL ROOFING REPAIR AND REPLACEMENT LINE # DETAILED DESCRIPTION DETAIL I SPEC. REFERENCE UNIT OF MEASURE ESTIMATED QTY UNIT PRICE EXTENDED TOTAL 79 Metal roofing replacement (Maximum 10,000 SF) SPECS: Detail: G Series SF 5, , SPECS: Detail: G.1 04, G.304 & 80 G.306 Metal roof ridge closure repair SPECS: Detail: G.602 & G Metal roof penetration boot flashinq replacement LF EA 3, , I I I 82 Clean existing metal panel roof using soft wash and chemical solutions to remove staininq. SPECS: SF 2, SHINGLES REPAIR AND REPLACEMENT LINE # DETAILED DESCRIPTION DETAIL I SPEC. REFERENCE UNIT OF MEASURE ESTIMATED QTY UNIT PRICE EXTENDED TOTAL SPECS: Tab Asphalt Shingle Roofing- 5 Gable Roofs (Maximum 83 10,000 SF) SF 5,000_ , I Revised Page D-11 I Y EB I Addendum No.3

21 SPECS: Architectural Shingle Roofing - 5 Hip Roofs (Maximum , ,000 SF) SF 25,000 SPECS: , Laminated Asphalt Shingle Roofing- low slope roof with 85 self -adhesive SF 3,500 B.U.R.- REPAIR AND REPLACEMENT DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED LINE UNIT PRICE REFERENCE MEASURE QTY TOTAL # DETAILED DESCRIPTION 86 Build-up asphalt roofing replacement (Maximum 10,000 SPECS: SF 5,000 SF) Details: B-Series , BUR-Edge Repair SPECS: Detail: B1.01 & LF 50 B SPECS: BUR-Base Flashing Repair with Coating LF 15 Detail: B B SPECS: BUR-Install Roof Drain Insert and Flashing- Type 4" dia EA 5 Detail: 8.701& B , SPECS: BUR-Pitch Pan Repair EA 5 Detail: B BUR-Replace Pitch Pan -Type 8" x 8" SPECS: EA Detail: B.604 1, Revised Page D-12 I EB I Addendum No.3

22 92 SPECS: BUR-Cut and Patch Holes, Blisters and Ridges SF 250 Detail: B SINGLE-PLY- REPAIR AND REPLACEMENT LINE # DETAILED DESCRIPTION DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE REFERENCE MEASURE QTY TOTAL 93 Thermoplastic single-ply roofing replacement (Maximum SPECS: SF 30,000 10,000 SF) Details: D-Series , SPECS: Single-Ply- Replace Plumbing Stack or Pipe Flashing EA 5 Detail: D SPECS: Single-Ply- Repair Base Flashing LF 350 Detail: D , SPECS: Single-Ply- Install 3" dia roof drain Insert and Flashing EA 5 Detail: D , I j SPECS: Expansion joint repair LF 50 Detail: D I I 98 6" x 6" patch of 45 mil membrane heat-welded to existing SPECS: EA 500 I membrane , J 99 Patch of 45 mil membrane heat-welded to existing SPECS: SF 2,500 membrane , I I 100 Installation of aluminum roof drain inserts into existing 4" dia. roof drains, w/single-ly membrane fully adhered as specified SPECS: EA , ~ Revised Page D-13 /Y EB I Addendum No.3

23 101 Replacement of sealant along the top of existing SPECS: LF 1,000 termination bar Cleaning of existing roof membrane using soft wash and SPECS: SF chemical solutions to remove staining. MODIFIED BITUMEN - REPAIR AND REPLACEMENT LINE DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE # DETAILED DESCRIPTION REFERENCE MEASURE QTY TOTAL 103 Modified Bitumen (2-ply) roofing replacement (Maximum SPECS: SF 5, , ,000 SF) Details: C-Series 104 Modified Bitumen - Repair Plumbing Stack Flashing SPECS: EA Detail: C.601 I 105 Modified Bitumen - Pitch Pan Repair SPECS: EA Detail: C Modified Bitumen- Replace Pitch Pan- Type 8" x 8" SPECS: EA Modified Bitumen- Repair Base Flashing SPECS: LF 75 Detail: C.202-C Modified Bitumen - Cut and Patch Blisters and Ridges SPECS: SF 3, , Detail: C.201 =-J Revised Page D-14 j Y EB f Addendum No.3

24 109 Modified Bitumen- Install 4" dia. Roof Drain Insert and SPECS: Flashing Detail: C.701 EA , SPECS: Expansion joint repair Detail: C.401-C4.05 LF Repair of Bituminous sheet base flashing repair with aluminized coating. SPECS: LF Replacement of sealant along metal counter flashing termination. SPECS: LF Overflow scupper flashing repair. SPECS: EA , Detail: H.714& H Cleaning of existing roof membrane using soft wash and chemical solutions to remove staining. SPECS: SF COATING LINE DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE # DETAILED DESCRIPTION REFERENCE MEASURE QTY TOTAL 115 Coating - BUR or Modified Bitumen SPECS: SF 1, , Coating - Single-Ply SPECS: SF 15, , Coating - EPDM SPECS: SF , Revised Page D-15 I EB I Addendum No.3

25 LIGHTNING PROTECTION LINE # DETAILED DESCRIPTION DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE REFERENCE MEASURE QTY TOTAL 118 Provide copper conductor cable, including associated fittings and couplings. Minimum 100 LF. SPECS: LF 2, , Provide aluminum conductor cable, including associated fittings and couplings. Minimum 100 LF. SPECS: LF 2, , Provide aluminum threaded air terminal, 1/2" diameter, 10" - 18" in length. SPECS: EA , Provide aluminum threaded air terminal, 1/2" diameter, 24" - 48" in length. SPECS: EA , Provide aluminum threaded air terminal, 5/8" diameter, 10" - 18" in length. SPECS: EA , Provide aluminum threaded air terminal, 5/8" diameter, 24" - 48" in length. SPECS: EA , Provide copper threaded air terminal, 1/2" diameter, 10"- SPECS: EA " in length. 4, Provide copper threaded air terminal, 1/2" diameter, 24"- 48" in length. SPECS: EA , Provide copper threaded air terminal, 5/8" diameter, 10"- 18" in length. SPECS: EA , Revised Page D-16 I Y EB I Addendum No.3

26 127 Provide copper threaded air terminal, 5/8" diameter, 24"- 48" in length. SPECS: EA , Provide aluminum air terminal base for use on horizontal surfaces (adhesive mount). SPECS: EA son no 129 Provide cast bronze air terminal base for use on horizontal surfaces (adhesive mount). SPECS: EA , Provide aluminum air terminal base for use on vertical surfaces (mechanical mount). SPECS: EA , Provide cast bronze air terminal base for use on vertical surfaces (mechanical mount). SPECS: EA , Provide aluminum air terminal base for use on standing seam metal roofing (clamp-on mount). SPECS: EA , Provide cast bronze air terminal base for use on standing seam metal roofing (clamp-on mount). SPECS: EA , Provide aluminum cable mount for use on standing seam metal roofing (clamp-on mount). SPECS: EA , Provide cast bronze cable mount for use on standing seam metal roofing (clamp-on mount). SPECS: EA , Provide aluminum air terminal base for mounting on pipes (clamp-on mount). SPECS: EA , Revised Page D-17 I Y EB I Addendum No.3

27 137 Provide cast bronze air terminal base for mounting on SPECS: EA , pipes (clamp-on mount). 138 Test lightning protection system after roof work is complete. SPECS: EA , Provide U.L. Master Label for system once completed. Assume new system, or existing system had Master Label SPECS: EA , previously. 140 Provide plastic isolating sleeves for cables where dissimilar metals come in contact with one another. (i.e. copper SPECS: EA 100 cable extending over galvanized or aluminum edge metal) I I Provide 3/4" diameter by 20' long, copper clad steel 141 grounding rods. Grounding rods can be 10' in length with exothermic-fusion-welded sections to make required length. SPECS: EA , Reinstallation of the existing lightning protection cable clip SPECS: EA or air terminal base to the roof surface. MISCELLANEOUS LINE # DETAILED DESCRIPTION DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE REFERENCE MEASURE QTY TOTAL 143 Remove and dispose of metal gutter assembly, including SPECS: LF 500 hangars, straps, and fasteners , Remove and dispose of metal downspouts, including SPECS: LF 500 hangars, straps, and fasteners , Revised Page D-18 I Y EB I Addendum No.3

28 145 Install stainless steel gutter assembly, 5" X 6" average. Include metal gutter hangars and straps as detailed. Solder joints in the gutter assembly. Provide expansion SPECS: LF 500 joints within the gutter assembly at maximum 40-ft intervals. Provide positive slope for gutters to drain , Install stainless steel "K" style gutter assembly, 5" X 6" average. Include metal gutter hangars and straps as detailed. Solder joints in the gutter assembly. Provide SPECS: LF 500 expansion joints within the gutter assembly at maximum 40-ft intervals. Provide positive slope for gutters to drain , Provide stainless steel downspout, 4" x 5 average". SPECS: LF , Provide aluminum downspout, 4" x 5" average- with baked SPECS: LF 500 on enamel finish , Remove and replace existing plywood soffit at eave locations. Assume up to 3' Eave, 5/8" CDX plywood. SPECS: SF 500 Include fasteners and trim , I 150 Remove and replace existing vented vinyl soffit at eave locations. Assume up to 3' Eave. Include fasteners and SPECS: SF 500 trim , Remove and replace existing vented aluminum soffit at eave locations. Assume up to 3' eave, with baked on color SPECS: SF 500 coating. Include fasteners and trim , Provide for 2" nominal thickness wood framing repairs at rafter tail, fascia and eave locations. Include fasteners and SPECS: LF 2,000 metal connectors for securement of reinforcing members , /2-inch CDX Plywood Deck SPECS: SF 2, , Revised Page D-19 I Y EB I Addendum No.3

29 154 Temporary roof repair- Tarp with securement SF 1, , (various types of roofs) Emergency Response (<4 hrs) Surcharge. This surcharge is only applicable to emergency repairs. 155 Estimated Amount: 300, of emergency work for LS 0.50% 1, basic year, times(_%), equals emergency response 300,000 lump sum. Example 1% x 300,000 = 3, Trip Charge (Small Scale Repairs under 250 total) as EA , specified TOTAL ESTIMATED OPTION YEAR 1 ITEMS 79 THROUGH , I Revised Page D-20 1 Y EB I Addendum No.3

30 Y EB BID ITEM SCHEDULE OPTION YEAR 2 METAL ROOFING REPAIR AND REPLACEMENT LINE # DETAILED DESCRIPTION DETAIL I SPEC. REFERENCE UNIT OF MEASURE ESTIMATED QTY UNIT PRICE EXTENDED TOTAL 157 Metal roofing replacement (Maximum 10,000 SF) SPECS: Detail: G Series SF 5, , I SPECS: Detail: G.1 04, G & G.306 Metal roof ridqe closure repair SPECS: Detail: G.602 & G Metal roof oenetration boot flashing replacement LF EA 3, , Clean existing metal panel roof using soft wash and chemical solutions to remove staininq. SPECS: SF 2, SHINGLES -REPAIR AND REPLACEMENT LINE # DETAILED DESCRIPTION DETAIL I SPEC. REFERENCE UNIT OF MEASURE ESTIMATED QTY UNIT PRICE EXTENDED TOTAL SPECS: Tab Asphalt Shingle Roofing- 5 Gable Roofs (Maximum 10,000 SF) SF 5, , Revised Page D-21 I Y EB I Addendum No.3

31 162 SPECS: Architectural Shingle Roofing - 5 Hip Roofs (Maximum 10,000 SF) SF 25, , SPECS: Laminated Asphalt Shingle Roofing - low slope roof with self-adhesive SF 3, , B.U.R. - REPAIR AND REPLACEMENT LINE # DETAILED DESCRIPTION DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE REFERENCE MEASURE QTY TOTAL 164 Build-up asphalt roofing replacement (Maximum 10,000 SPECS: SF 5, , SF) Details: B-Series 165 BUR-Edge Repair SPECS: Detail: B 1.01 & LF B SPECS: BUR-Base Flashing Repair with Coating LF 15 Detail: B B I 167 SPECS: BUR-Install Roof Drain Insert and Flashing -Type 4" dia EA Detail: 8.701& , SPECS: BUR-Pitch Pan Repair EA 5 Detail: SPECS: BUR-Replace Pitch Pan -Type 8" x 8" EA , Detail: ! i Revised Page D-22 I Y EB I Addendum No.3

32 170 SPECS: BUR-Cut and Patch Holes, Blisters and Ridges SF 250 Detail: SINGLE-PLY- REPAIR AND REPLACEMENT LINE # DETAILED DESCRIPTION DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE REFERENCE MEASURE QTY TOTAL 171 Thermoplastic single-ply roofing replacement (Maximum SPECS: SF 30,000 10,000 SF) Details: D-Series , i 172 SPECS: Single-Ply- Replace Plumbing Stack or Pipe Flashing EA 5 Detail: D SPECS: Single-Ply- Repair Base Flashing LF 350 Detail: D.201-D , SPECS: Single-Ply- Install 3" dia roof drain Insert and Flashing EA 5 Detail: D.201-D , SPECS: Expansion joint repair LF 50 Detail: D.401-D " x 6" patch of 45 mil membrane heat-welded to existing SPECS: EA , membrane Patch of 45 mil membrane heat-welded to existing SPECS: SF 2, , membrane ~ ---- Revised Page D-23 I Y EB I Addendum No.3

33 178 Installation of aluminum roof drain inserts into existing 4" dia. roof drains, w/single-ly membrane fully adhered as specified SPECS: EA , Replacement of sealant along the top of existing SPECS: LF 1, termination bar 180 Cleaning of existing roof membrane using soft wash and SPECS: SF chemical solutions to remove staining. MODIFIED BITUMEN REPAIR AND REPLACEMENT DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED LINE UNIT PRICE REFERENCE MEASURE QTY TOTAL # DETAILED DESCRIPTION 181 Modified Bitumen (2-ply) roofing replacement (Maximum SPECS: SF 5, ,000 SF) Details: C-Series 182 Modified Bitumen - Repair Plumbing Stack Flashing SPECS: EA 5 Detail: C Modified Bitumen - Pitch Pan Repair SPECS: EA Detail: C Modified Bitumen - Replace Pitch Pan - Type 8" x 8" SPECS: EA Modified Bitumen- Repair Base Flashing SPECS: LF 75 Detail: C.202-C Modified Bitumen - Cut and Patch Blisters and Ridges SPECS: SF 3, , ' Detail: C.201 I Revised Page D-24 I EB I Addendum No.3

34 187 Modified Bitumen - Install 4" dia. Roof Drain Insert and SPECS: EA , Flashing Detail: C SPECS: Expansion joint repair LF 50 Detail: C.401-C Repair of Bituminous sheet base flashing repair with SPECS: LF aluminized coating. 190 Replacement of sealant along metal counter flashing SPECS: LF termination. 191 Overflow scupper flashing repair. SPECS: EA , Detail: H.714& H Cleaning of existing roof membrane using soft wash and SPECS: SF l25.00 chemical solutions to remove staining. COATING LINE # DETAILED DESCRIPTION DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE REFERENCE MEASURE QTY TOTAL I 193 Coating - BUR or Modified Bitumen SPECS: SF 1, , I 194 Coating - Single-Ply SPECS: SF 15, , Coating - EPDM SPECS: SF , Revised Page D-25 1 Y EB I Addendum No.3

35 LIGHTNING PROTECTION LINE # DETAILED DESCRIPTION DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE REFERENCE MEASURE QTY TOTAL I 196 Provide copper conductor cable, including associated SPECS: LF 2, fittings and couplings. Minimum 100 LF. 9, Provide aluminum conductor cable, including associated fittings and couplings. Minimum 100 LF. SPECS: LF 2, , Provide aluminum threaded air terminal, 1/2" diameter, 10" - 18" in length. SPECS: EA , Provide aluminum threaded air terminal, 1/2" diameter, 24" - 48" in length. SPECS: EA , Provide aluminum threaded air terminal, 5/8" diameter, 10" - 18" in length. SPECS: EA , Provide aluminum threaded air terminal, 5/8" diameter, 24" - 48" in length. SPECS: EA , Provide copper threaded air terminal, 1/2" diameter, 10"- 18" in length. SPECS: EA , Provide copper threaded air terminal, 1/2" diameter, 24"- 48" in length. SPECS: EA , Revised Page D-26 I Y EB I Addendum No.3

36 204 Provide copper threaded air terminal, 5/8" diameter, 10"- 18" in length. SPECS: EA , Provide copper threaded air terminal, 5/8" diameter, 24"- 48" in length. SPECS: EA , Provide aluminum air terminal base for use on horizontal surfaces (adhesive mount). SPECS: EA , Provide cast bronze air terminal base for use on horizontal surfaces (adhesive mount). SPECS: EA , Provide aluminum air terminal base for use on vertical surfaces (mechanical mount). SPECS: EA , Provide cast bronze air terminal base for use on vertical surfaces (mechanical mount). SPECS: EA , Provide aluminum air terminal base for use on standing seam metal roofing (clamp-on mount). SPECS: EA , Provide cast bronze air terminal base for use on standing seam metal roofing (clamp-on mount). SPECS: EA , Provide aluminum cable mount for use on standing seam metal roofing (clamp-on mount). SPECS: EA , Revised Page D-27 I Y EB I Addendum No.3

37 ~--~~~ Provide cast bronze cable mount for use on standing seam SPECS: EA , metal roofing (clamp-on mount). 214 Provide aluminum air terminal base for mounting on pipes SPECS: EA , (clamp-on mount). 215 Provide cast bronze air terminal base for mounting on SPECS: EA , pipes (clamp-on mount). 216 Test lightning protection system after roof work is complete. SPECS: EA , Provide U.L. Master Label for system once completed. Assume new system, or existing system had Master Label SPECS: EA , previously. 218 Provide plastic isolating sleeves for cables where dissimilar metals come in contact with one another. (i.e. copper SPECS: EA i cable extending over galvanized or aluminum edge metal) I Provide 3/4" diameter by 20' long, copper clad steel 219 grounding rods. Grounding rods can be 10' in length with , SPECS: EA 50 exothermic-fusion-welded sections to make required length. 220 Reinstallation of the existing lightning protection cable clip SPECS: EA 10 or air terminal base to the roof surface i I MISCELLANEOUS LINE L_# DETAILED DESCRIPTION DETAIL I SPEC. UNIT OF ESTIMATED EXTENDED UNIT PRICE REFERENCE MEASURE QTY TOTAL I Revised Page D-28 I EB I Addendum No.3

38 Remove and dispose of metal gutter assembly, including SPECS: LF , hangars, straps; and fasteners. 222 Remove and dispose of metal downspouts, including hangars, straps, and fasteners. SPECS: LF , Install stainless steel gutter assembly, 5" X 6" average. Include metal gutter hangars and straps as detailed. Solder joints in the gutter assembly. Provide expansion SPECS: LF 500 joints within the gutter assembly at maximum 40-ft intervals. Provide positive slope for gutters to drain. 6, Install stainless steel "K" style gutter assembly, 5" X 6" average. Include metal gutter hangars and straps as detailed. Solder joints in the gutter assembly. Provide SPECS: LF 500 expansion joints within the gutter assembly at maximum 40-ft intervals. Provide positive slope for gutters to drain , Provide stainless steel downspout, 4" x 5 average". SPECS: LF , Provide aluminum downspout, 4" x 5" average - with baked SPECS: LF , on enamel finish. 227 Remove and replace existing plywood soffit at eave locations. Assume up to 3' Eave, 5/8" COX plywood. SPECS: SF 500 Include fasteners and trim , Remove and replace existing vented vinyl soffit at eave locations. Assume up to 3' Eave. Include fasteners and SPECS: SF 500 trim , Remove and replace existing vented aluminum soffit at eave locations. Assume up to 3' eave, with baked on color SPECS: SF 500 coating. Include fasteners and trim. --- ~~ ~~--, ~ , Revised Page D-29 I EB I Addendum No.3

39 230 Provide for 2" nominal thickness wood framing repairs at rafter tail, fascia and eave locations. Include fasteners and SPECS: LF 2,000 metal connectors for securement of reinforcing members , /2-inch CDX Plywood Deck SPECS: SF 2, , Temporary roof repair- Tarp with securement SF 1, , (various types of roofs) Emergency Response (<4 hrs) Surcharge. This surcharge is only applicable to emergency repairs. 233 Estimated Amount: 300, of emergency work for LS 0.50 % 1, basic year, times(_%), equals emergency response 300,000 lump sum. Example 1% x 300,000 = 3, Trip Charge (Small Scale Repairs under 250 total) as EA , specified TOTAL ESTIMATED OPTION YEAR f ITEMS 157 THROUGH TOTAL ESTIMATED BID: (BASE YEAR PLUS OPTION YEARS 1 AND 2) 2,048, Revised Page D-30 I Y EB I Addendum No.3

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

121

122

123

124

125

126

127

128

129

130

131

132

133

134

135

136

137

138

139

140

141

142

143

144

145

AIR TERMINALS: COPPER

AIR TERMINALS: COPPER AIR TERMINALS: COPPER A ADAPTER TYPE B LESS ADAPTER LA TYPE A B C A B C A B C 3 8 COPPER POINTS (CLASS I ONLY) 1 2 COPPER POINTS (CLASS I OR II) 5 8 COPPER POINTS (CLASS I OR II) THE 3 8 COPPER AND ALUMINUM

More information

DISTRIBUTION OF QUANTITIES

DISTRIBUTION OF QUANTITIES DISTRIBUTION OF QUANTITIES Index: 1 Table of Contents - Distribution of Quantities R.I. Contract - 2018-CB-059 Description Page 201.0415 REMOVE AND DISPOSE GUARDRAIL AND POST ALL TYPES 1 201.9901 REMOVE

More information

SECTION TAPER-LOC DRY GLAZE GLASS RAILING SYSTEMS. A. Monolithic Tempered Glass Dry Glazed Railing Assemblies.

SECTION TAPER-LOC DRY GLAZE GLASS RAILING SYSTEMS. A. Monolithic Tempered Glass Dry Glazed Railing Assemblies. 1 SECTION 05 7310 TAPER-LOC DRY GLAZE GLASS RAILING SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Monolithic Tempered Glass Dry Glazed Railing Assemblies. 1.2 RELATED SECTIONS A. Section 05 5000 - Metal

More information

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT TABLE OF CONTENTS INTRODUCTORY INFORMATION 00 00 10 Title Page 00 00 20 Table of Contents DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT Section 00 02 00 Notice to Bidders

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 5 APPR:LWB:DBP:07-31-13

More information

SECTION EGR ELEVATED GLASS RAILING SYSTEMS. A. Tempered Glass Wet Glazed in Elevated Railing Assemblies.

SECTION EGR ELEVATED GLASS RAILING SYSTEMS. A. Tempered Glass Wet Glazed in Elevated Railing Assemblies. 1 SECTION 05 7310 EGR ELEVATED GLASS RAILING SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Tempered Glass Wet Glazed in Elevated Railing Assemblies. 1.2 RELATED SECTIONS A. Section 05 5000 - Metal Fabrications

More information

TOWN OF MANCHESTER GENERAL SERVICES DEPARTMENT 494 MAIN STREET P.O. BOX 191 MANCHESTER, CONNECTICUT

TOWN OF MANCHESTER GENERAL SERVICES DEPARTMENT 494 MAIN STREET P.O. BOX 191 MANCHESTER, CONNECTICUT TOWN OF MANCHESTER GENERAL SERVICES DEPARTMENT 494 MAIN STREET P.O. BOX 191 MANCHESTER, CONNECTICUT 06045-0191 TRAFFIC SIGNAL INSTALLATIONS MIDDLE TURNPIKE EAST AT SUMMIT STREET MIDDLE TURNPIKE EAST AT

More information

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE / 2 Ground Power Modules And Accessories For Healthcare Facilities Technical Bulletin NAE2092320 / 10.2011 Ground Power Modules Hospital grade outlet modules Introduction BENDER series GPM ground and power

More information

Emery County Senior Center Green River 06/07

Emery County Senior Center Green River 06/07 SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 6 APPR:MDW:JVG:06-08-18

More information

SECTION A. Tempered Glass Free Standing Swing Gate Post Assemblies.

SECTION A. Tempered Glass Free Standing Swing Gate Post Assemblies. Page 1 of 5 SECTION 05 7310 CRL-BLUMCRAFT FREE STANDING GLASS SWING GATE POST SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Tempered Glass Free Standing Swing Gate Post Assemblies. 1.2 RELATED SECTIONS

More information

SECTION PROJECTOR LIFTS AND MOUNTS. A. Refer to Section [ Submittal Procedures] [Insert section number and title].

SECTION PROJECTOR LIFTS AND MOUNTS. A. Refer to Section [ Submittal Procedures] [Insert section number and title]. (Specifier Note: The purpose of this guide specification is to assist the Specifier in correctly specifying AeroLift motorized projector lifts and their installation. The Specifier needs to edit these

More information

ROLLING COUNTER SHUTTERS

ROLLING COUNTER SHUTTERS 500 ROLLING COUNTER SHUTTERS EXCEPTIONAL SECURITY AND AESTHETICS WAYNE DALTON COMMERCIAL DOOR SYSTEMS The Wayne Dalton Rolling Counter Shutter system provides the perfect solution for smaller openings

More information

Webb Core Cleanroom Wall System

Webb Core Cleanroom Wall System Webb Core Cleanroom Wall System PART 1 GENERAL 1.1 WORK INCLUDED A. This Section specifies the requirements necessary to furnish, install and complete a cleanroom wall system (CRW) including, but not limited

More information

QUICKBOLT I NS TALL ATI ON I N S TR UC T IO NS

QUICKBOLT I NS TALL ATI ON I N S TR UC T IO NS QUICKBOLT I NS TALL ATI ON I N S TR UC T IO NS 1 2 3 RECOMMENDED MATERIALS Rafter locater Chalk or crayon 3/16 Drill Bit Sealant INSTALLATION INSTRUCTIONS 1. Locate and mark the rafters. 2. Predrill the

More information

CONTRACT DOCUMENTS. for the CIGAR LAKE: RECLAIMED WATER DISTRIBUTION PUMP STATION (ITB - U ) PREPARED BY

CONTRACT DOCUMENTS. for the CIGAR LAKE: RECLAIMED WATER DISTRIBUTION PUMP STATION (ITB - U ) PREPARED BY Addendum No. 2 December 19, 2006 CONTRACT DOCUMENTS for the CIGAR LAKE: RECLAIMED WATER STRIBUTION PUMP STATION (ITB - U - 07-04) PREPARED BY CPH ENGINEERS, INC. P.O. BOX 2808 SANFORD, FL 32772-2808 PHONE:

More information

CABLE TIES AND ACCESSORIES Air Handling Cable Ties

CABLE TIES AND ACCESSORIES Air Handling Cable Ties Air Handling Cable Ties Plenum Rated BUrgundy nylon Ideal Application: Air Handling Spaces, above drop ceilings and below raised flooring meets UL 1565 low smoke generation, low heat release, and mechanical

More information

Viking Enviroclad Membrane

Viking Enviroclad Membrane 103 Viking Enviroclad Membrane STP110 Enviroclad Membrane Description Colour Thickness Width Length Weight m 3 Country of Origin STP100 Enviroclad White 1.14mm 3.05m 30.4m 155kg 0.20 USA STP110 Enviroclad

More information

December 16, 2016 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA ADDENDUM NO. 2 / IFB NO. Y PH

December 16, 2016 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA ADDENDUM NO. 2 / IFB NO. Y PH December 16, 2016 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA ADDENDUM NO. 2 / IFB NO. Y17-722-PH SOUTH WATER RECLAMATION FACILITY SODIUM HYPOCHLORITE STORAGE AND FEED SYSTEMS IMPROVEMENTS BID

More information

(SEE SECTIONS VII AND VIII OF THE COVENANTS)

(SEE SECTIONS VII AND VIII OF THE COVENANTS) P.0. Box 7035 Covington, Washington 98042 Office (253) 631-9892 * Fax (253) 630-0988 winterwoodhoa@comcast.net Please put ACC Request in e-mail subject line ARCHITECTURAL CONTROL COMMITTEE (ACC) PROJECT

More information

SECTION WIRING DEVICES

SECTION WIRING DEVICES PART 1 - GENERAL... 1 1.1 RELATED DOCUMENTS... 1 1.2 SUMMARY... 1 1.3 DEFINITIONS... 1 1.4 REFERENCES... 2 1.5 SUBMITTALS... 2 1.6 QUALITY ASSURANCE... 2 1.7 COORDINATION... 2 PART 2 - PRODUCTS... 2 2.1

More information

Sorcerer. Advanced Software for Roof Modeling and Estimating. Using the software for the first time

Sorcerer. Advanced Software for Roof Modeling and Estimating. Using the software for the first time Sorcerer Also suitable for Roof Magician, Roof Wizard, Roof Maestro and Roof Master.* Advanced Software for Roof Modeling and Estimating Using the software for the first time Document Issue 1.1.0 - Monday,

More information

TE CONNECTIVITY (TE) 09 MSFL RCPT RA 318 (IN,FM,BL) AMPLIMITE Standard. TE Internal Number: Alias ID:

TE CONNECTIVITY (TE) 09 MSFL RCPT RA 318 (IN,FM,BL) AMPLIMITE Standard. TE Internal Number: Alias ID: TE Connectivity: Every Connection Counts 2015 TE Connectivity Ltd. family of companies. All Rights Reserved CONNECTORS PCB D-SUB CONNECTORS TE CONNECTIVITY (TE) 09 MSFL RCPT RA 318 (IN,FM,BL) AMPLIMITE

More information

UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS TABLE OF CONTENTS

UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS TABLE OF CONTENTS Table of Contents Introduction Changes from August 1, 2016 version to April 30, 2018 Supplemental General Requirements (asterisk * indicates revised) 00 00 02 Terms 00 00 03 Modifications to General Requirements

More information

WITH ROLLED STOP COUPLING REDUCER C X C C

WITH ROLLED STOP COUPLING REDUCER C X C C Copperfit Industries Inc. 1280 E. 9th St. Pomona, CA 91766 Tel: (909) 622-6100 (866) 200-1888 Fax: (909) 622-5566 WWW.COPPERFIT.COM COPPER PRESSURE FITTINGS Effective Date: Jan 2018 Version: 2C201801 Spread

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MICROWAVE VEHICLE DETECTION SYSTEM

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MICROWAVE VEHICLE DETECTION SYSTEM MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MICROWAVE VEHICLE DETECTION SYSTEM ITS:CLC 1 of 6 APPR:LWB:DBP:07-31-13 FHWA:APPR:09-23-13 a. Description. This work consists of one or more

More information

Cool Roof Collection. Owens Corning Shingles Meet Title 24 Requirements. TruDefinition Duration COOL Mountainside

Cool Roof Collection. Owens Corning Shingles Meet Title 24 Requirements. TruDefinition Duration COOL Mountainside Cool Roof Collection Owens Corning Shingles Meet Title 24 Requirements FEATURES THE TruDefinition Duration COOL Mountainside In addition to meeting Title 24 requirements, Owens Corning Cool Roof Collection

More information

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Individually Mounted Switches and Circuit Breakers Used for the following: a. Service

More information

29 June Termination of Tables 2, 3 and 4 P0151

29 June Termination of Tables 2, 3 and 4 P0151 29 June 2017 Termination of Tables 2, 3 and 4 P0151 The price indices for materials used in certain industries (Table 3) and selected materials (Table 4) were temporarily suspended from publication in

More information

Computer Network Design Guide Existing Systems 1 / 6

Computer Network Design Guide Existing Systems 1 / 6 COMPUTER NETWORK DESIGN GUIDELINE FOR EXISTING SYSTEMS DOCUMENT NUMBER: 16765 APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL DATE OF ISSUE: 11-27-06 - First Issued NOTES: The attached guideline should

More information

UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS TABLE OF CONTENTS

UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS TABLE OF CONTENTS Table of Contents Introduction Changes from September 16, 2013 version to January 16, 2015 version Supplemental General Requirements (asterisk * indicates revised) 00 00 02 Terms * 00 00 03 Modifications

More information

Third Party Tested. Sam Roberts & Associates, Inc.

Third Party Tested. Sam Roberts & Associates, Inc. Perfect Fit Solvent Weld DWV Fittings Injection Molded in Sizes 4 12 Fabricated in Sizes 10 24 D Applications The most complex installations require the most advanced fittings. Injection molded Perfect

More information

SECTION SWITCHGEAR

SECTION SWITCHGEAR SECTION 26 23 13 SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Specifications. S&C Line-Rupters. For Line and Cable Switching. Outdoor Transmission (115 kv through 230 kv) Conditions of Sale

Specifications. S&C Line-Rupters. For Line and Cable Switching. Outdoor Transmission (115 kv through 230 kv) Conditions of Sale Outdoor Transmission ( kv through 230 kv) For Line and Cable Switching Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified

More information

Granite Shoals, TX San Antonio, TX 78251

Granite Shoals, TX San Antonio, TX 78251 Water Bid Items 1 226.00 LF (103) Remove Concrete Curb $2.00 $452.00 $1.05 $237.30 $5.00 $1,130.00 $5.00 $1,130.00 2 672.00 SF (103) Remove Sidewalks and Driveways $3.00 $2,016.00 $1.75 $1,176.00 $5.00

More information

BELLOWS COVERS AND.

BELLOWS COVERS AND. BELLOWS AND COVERS www.joycedayton.com BELLOWS AND COVERS REDUCE EXPENSIVE MAINTENANCE AND DOWN TIME Protect your Equipment Investment When bellows and covers are fitted to machinery, expensive maintenance

More information

BID ISSUE DATE: JUNE 2016

BID ISSUE DATE: JUNE 2016 July 11, 2016 To All Plan Holders: ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS FOR CHATHAM COUNTY SOLID WASTE AND RECYCLING RECYCLING STATION BID ISSUE DATE: JUNE 2016 The following revisions, additions and

More information

March 6, Contract Information IFB#412. Multiple Awardees. Required: No Form on File: Not Applicable. Required: Yes Form on File: Yes

March 6, Contract Information IFB#412. Multiple Awardees. Required: No Form on File: Not Applicable. Required: Yes Form on File: Yes DEPARTMENT OF BUSINESS & FINANCIAL SERVICES PROCUREMENT DIVISION 21000 Education Court, Suite #301 Ashburn, VA 20148 Phone (571) 252-1270 Fax (571) 252-1432 March 6, 2017 Title: Contract Information Library

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.

More information

DISTRIBUTION OF QUANTITIES

DISTRIBUTION OF QUANTITIES DISTRIBUTION OF QUANTITIES Index: 1 Table of Contents - Distribution of Quantities R.I. Contract - 2018-CB-109 Description Page 201.0403 REMOVE AND DISPOSE SIDEWALKS 1 201.0407 REMOVE AND DISPOSE PAVEMENT

More information

BS EN Class H, BS 7430 UL467 (CR105) Tightening torque 15 Nm mm mm kg CR525

BS EN Class H, BS 7430 UL467 (CR105) Tightening torque 15 Nm mm mm kg CR525 Rod to tape clamp (type A) Nominal rod Max. conductor 1 2 12.7 mm 26 x 12 mm 0.1 kg CR10 8 16 mm 26 x 12 mm 0.1 kg CR10 4 20 mm 26 x 10 mm 0.1 kg CR10 8 16 mm 0 x 2 mm 0.16 kg CR108 4 20 mm 0 x 2 mm 0.16

More information

Product catalogue. Aztec International S.A., ul. Bułgarska 63/65, Poznań, Poland, phone ,

Product catalogue. Aztec International S.A., ul. Bułgarska 63/65, Poznań, Poland, phone , Product catalogue Delivery Programme 2014 Status 02/2014 - Subject to change - Index Rail system... 4 Accessories mounting rails... 11 Rail connectors... 11 Cross connectors... 12 Module clamps... 13 Module

More information

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS SECTION 264313 - TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and

More information

METRIC MIL-C-83522/16B w/amendment 1 17 AUGUST 2004 SUPERSEDING MIL-C-83522/16B 11 May 1995 MILITARY SPECIFICATION SHEET

METRIC MIL-C-83522/16B w/amendment 1 17 AUGUST 2004 SUPERSEDING MIL-C-83522/16B 11 May 1995 MILITARY SPECIFICATION SHEET METRIC MIL-C-83522/16B 17 AUGUST 2004 SUPERSEDING MIL-C-83522/16B 11 May 1995 MILITARY SPECIFICATION SHEET CONNECTOR, FIBER OPTIC, SINGLE TERMINUS, PLUG, BAYONET COUPLING (ST STYLE), 2.5 MILLIMETERS DIAMETER

More information

CONSTRUCTION & DEVELOPMENT MANUAL SUMTER COUNTY, FLORIDA

CONSTRUCTION & DEVELOPMENT MANUAL SUMTER COUNTY, FLORIDA CONSTRUCTION & DEVELOPMENT MANUAL SUMTER COUNTY, FLORIDA Original: June 1, 2004 Revised: May 31, 2005 Revised: August 8, 2006 Revised: September 1, 2006 Revised: August 20, 2007 Revised: November 1, 2011

More information

Stainless Steel Sinks

Stainless Steel Sinks CORNER Drain Sinks 13" deep bowls All-Coved corner construction 1.5 inch diameter radius bullnose Overflow tube and drain included 4 inch x 4 inch x 8 inch high perforated drain guard assembly included

More information

PEX Press EN_US_2014_V2.indb 79 2/7/ :15:37 AM

PEX Press EN_US_2014_V2.indb 79 2/7/ :15:37 AM 79 For both residential and commercial applications, Viega PEX Press is the trusted way to join PEX tubing. As the world leader in press technology, Viega was the first to offer a press system to the PEX

More information

March Roof Product Guide. Warehouses located in Atlanta, GA and Temecula, CA

March Roof Product Guide. Warehouses located in Atlanta, GA and Temecula, CA March 2018 Roof Product Guide Warehouses located in Atlanta, GA and Temecula, CA 1 Table of Contents Product Portfolio...3 RBI Versatile Roof Mount Solution RS-VS...5 Rails & Splice Connectors (East)...6

More information

PRODUCT DATA SHEET SARNAFIL G 410 ENERGYSMART ROOF MEMBRANE FELTBACK

PRODUCT DATA SHEET SARNAFIL G 410 ENERGYSMART ROOF MEMBRANE FELTBACK PRODUCT DATA SHEET SARNAFIL G 410 ENERGYSMART ROOF MEMBRANE 48 60 72 80 FELTBACK Roof is a PVC thermoplastic membrane produced with an integral fiberglass mat reinforcement for excellent dimensional stability,

More information

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number Installation Note Source Attenuators and Bias Tees Upgrade Kit For E8362B/C PNA Series Microwave Network Analyzers Network Analyzer Model Number Upgrade Kit Part Number E8362B/C E8362-60115 Agilent Part

More information

RESTRICTED WORLD TRADE G/IT/SPEC/8/Rev.1 23 February 1998 ORGANIZATION PROPOSED ADDITIONS TO PRODUCT COVERAGE. Submission by Australia.

RESTRICTED WORLD TRADE G/IT/SPEC/8/Rev.1 23 February 1998 ORGANIZATION PROPOSED ADDITIONS TO PRODUCT COVERAGE. Submission by Australia. RESTRICTED WORLD TRADE G/IT/SPEC/8/Rev.1 23 February 1998 ORGANIZATION (98-0664) Committee of Participants on the Expansion of Trade in Information Technology Products Original: English PROPOSED ADDITIONS

More information

Chapman Fence Company, Inc. (OC) UNIT PRICE

Chapman Fence Company, Inc. (OC) UNIT PRICE BID TABULATION Page 1 of 6 SECTION A - GALVANIZED CHAIN LINK FENCE 1 3 tall complete fence installation 10 lf $9.00 $90.00 $9.25 $92.50 $11.15 $111.50 2 4 tall complete fence installation 260 lf $10.72

More information

8 Submersible Motors Hi-Temp 75

8 Submersible Motors Hi-Temp 75 Applications These motors are built for dependable operation in vertical 8 diameter or larger wells, in applications with higher temperature, higher thrust or low flow. Basic Features Able to operate in

More information

XS Roof Type Overview

XS Roof Type Overview XS Roof Type Installation Overview XS Linked CABLE system ON STEEL ROOF Rigorous testing has proven the strength and resistance of the XS Linked Cable System on a steel roof. The main components of an

More information

ING CITY COUNCIL AGENDA REPORT. Honorable Mayor and City Council Members. Director of Public Works - Utilities. Final Payment Applications

ING CITY COUNCIL AGENDA REPORT. Honorable Mayor and City Council Members. Director of Public Works - Utilities. Final Payment Applications City of RED W1' ING CITY COUNCIL AGENDA REPORT TO: Honorable Mayor and City Council Members FROM: Bob Stark Deputy Director of Public Works - Utilities Agenda Item No.: 8- M Meeting Date: September 25,

More information

Mounting Instructions for MTP Modules

Mounting Instructions for MTP Modules VISHAY SEMICONDUCTORS www.vishay.com Modules By Kevin Liu This application note introduces Vishay s MTP rectifier-switch modules and discusses the assembly and PCB issues involved in their use. MTP modules

More information

M-Line Series MN Multi-Pin Plugs and Receptacles Vac, Vdc

M-Line Series MN Multi-Pin Plugs and Receptacles Vac, Vdc Applications Designed for the roughest industrial applications, providing reliable, rugged service for power, control and instrumentation. For use in the roughest industrial applications, ranging from:

More information

LEE DAN COMMUNICATIONS, INC.

LEE DAN COMMUNICATIONS, INC. THE NAME TO KNOW IN POSTAL SPECIALTIES LEE DAN COMMUNICATIONS, INC. 55 Adams Avenue, Hauppauge NY 788-3699 YEAR AFTER YEAR, S U G G E S T E D S P E C I F I C A T I O N S OUR REPUTATION IS BASED ON PERFORMANCE

More information

CITY OF FREMONT SPECIFICATIONS 2017 WATER & SEWER MAINTENANCE SUPPLIES

CITY OF FREMONT SPECIFICATIONS 2017 WATER & SEWER MAINTENANCE SUPPLIES CITY OF FREMONT SPECIFICATIONS 2017 WATER & SEWER MAINTENANCE SUPPLIES All bidders MUST submit product specifications, literature describing items, manufacturers name, product code and part numbers with

More information

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console 1993 Specifications CSJ 0598-01-057 1.0 Description SPECIAL SPECIFICATION ITEM 6398 Transportation Management Console This Item shall govern for the furnishing and installation of Transportation Management

More information

cpci-e3 series Cutting Edge, Push Button, Locking Ejector for CompactPCI Assemblies

cpci-e3 series Cutting Edge, Push Button, Locking Ejector for CompactPCI Assemblies cpci-e3 series Cutting Edge, Push Button, Locking Ejector for CompactPCI Assemblies IEEE 1101.10 and PICMG 2.0 Compliant Compact size and unique aesthetics Innovative positive locking, simple push button

More information

LEE DAN COMMUNICATIONS, INC.

LEE DAN COMMUNICATIONS, INC. THE NAME TO KNOW IN POSTAL SPECIALTIES LEE DAN COMMUNICATIONS, INC. 155 Adams Avenue, Hauppauge NY 11788-3699 YEAR AFTER YEAR, S U G G E S T E D S P E C I F I C A T I O N S OUR REPUTATION IS BASED ON PERFORMANCE

More information

PV Module Installation Instructions

PV Module Installation Instructions Name 1601A Page 1 / 8 Name 1601A Page 2 / 8 1 Introduction Thanks for purchasing PV modules of HT SOLAR ENERGY JOINT STOCK COMPANY This manual refers to PV modules manufactured and sold by HT Turkey. This

More information

System 16 Precision-Clamping & Welding Bench

System 16 Precision-Clamping & Welding Bench UKOP-2.04K16 System 16 Precision-Clamping & Welding Bench System 16 Contents System 16 S4 Welding bench Aluminium Plate with holes Bench legs Stops Squares Prisms Bolts Clamps Fast clamping 2-3 4-5 6-7

More information

The Hip Roof Style We Customize Roof Styles to Match You Home Base Price Includes. Shingles

The Hip Roof Style We Customize Roof Styles to Match You Home Base Price Includes. Shingles Dormer Fully Constructed on your site or Delivered 6 Stud @ 16 OC Primed 3/8 Smartside T-1-11 8 OC 4 Standard Wooden Double (With Keyed Latch) Vinyl Arch Rounded with Braces & Vinyl Shakes The Hip We Customize

More information

Dial Thermometer. Particularities. Brief description. Technical data. Page 1/6. Data Sheet

Dial Thermometer. Particularities. Brief description. Technical data. Page 1/6. Data Sheet Dial Thermometer Data Sheet 608202 Page 1/6 - discontinued - Particularities Temperature indicator for panel mounting Class 2 IP53 front protection Housing sizes: 52 mm and 60 mm dia. Bezel: 48x48 mm,

More information

AMT-12 AMT-15. Professional Loudspeakers. Installation and Use Manual

AMT-12 AMT-15. Professional Loudspeakers. Installation and Use Manual AMT-12 AMT-15 Professional Loudspeakers Installation and Use Manual 2008 Bogen Communications, Inc. Specifications subject to change without notice. 54-2183-01C 0907 Table of Contents Introduction 2 Speaker

More information

SECTION MODEL INDOOR SCOREBOARD. A. Four-face electronic scoreboard and control console for indoor use.

SECTION MODEL INDOOR SCOREBOARD. A. Four-face electronic scoreboard and control console for indoor use. SECTION 116643 MODEL 2650-4 INDOOR SCOREBOARD PART 1 GENERAL 1.01 SECTION INCLUDES A. Four-face electronic scoreboard and control console for indoor use. 1.02 REFERENCES A. Standard for Electric Signs,

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

Karvo Paving Company Hudson Drive Stow, OH Unit Price Labor & Material Total Unit Price Labor Unit Price Material

Karvo Paving Company Hudson Drive Stow, OH Unit Price Labor & Material Total Unit Price Labor Unit Price Material ITEM SPEC CMS DESCRIPTION QUANTITY Labor Labor Labor 1 201 ODOT CLEARING AND GRUBBBING 1 $13,000.00 $0.00 $13,000.00 $13,000.00 $6,800.00 $10,200.00 $17,000.00 $17,000.00 $75,000.00 $0.00 $75,000.00 $75,000.00

More information

IRONRIDGE PRODUCT CATALOG

IRONRIDGE PRODUCT CATALOG IRONRIDGE PRODUCT CATALOG Effective March 15, 2011 Product Catalog March 15, 2011 2 What s New: 1. New Products: a. End Caps for XRS and XRL Rails Page 6 b. End Clamps I, J, K, Page 7 and updated sizing

More information

Annexure-1 (CC no )

Annexure-1 (CC no ) Annexure-1 (CC no. 77627) TECHNICAL SPECIFICATIONS OF EXISTING LIGHTNING ARRESTORS S. No. Description Parameter 1. Type Station class heavy duty zinc oxide gapless 2. Applicable standard IEC-60099-4 /

More information

Pixus Technologies Catalog

Pixus Technologies Catalog The Power of Embedded Ingenuity Pixus Technologies Catalog Kaparel, Ripac, & Vario Brand Products www.pixustechnologies.com sales@pixustechnologies.com US: 96.524.8242 CAN: 59.885.5775 Product Diversity

More information

PRO I Series CAPACITANCE PROBE

PRO I Series CAPACITANCE PROBE Price $5.00 PRO I Series CAPACITANCE PROBE OPERATING INSTRUCTIONS PLEASE READ CAREFULLY TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 1.0 INTRODUCTION... 4 2.0 APPLICATIONS... 4 3.0 INSTALLATION... 4 3.1

More information

Assembly and Maintenance

Assembly and Maintenance Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines

More information

SECTION WIRING DEVICES

SECTION WIRING DEVICES SECTION 16141 WIRING DEVICES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

LEE DAN COMMUNICATIONS, INC.

LEE DAN COMMUNICATIONS, INC. THE NAME TO KNOW IN POSTAL SPECIALTIES LEE DAN COMMUNICATIONS, INC. 155 Adams Avenue, Hauppauge NY 11788-3699 YEAR AFTER YEAR, S U G G E S T E D S P E C I F I C A T I O N S OUR REPUTATION IS BASED ON PERFORMANCE

More information

Kully Reference Book

Kully Reference Book Kully Reference Book Serving the Greater Mid-West since 1946 Angles Channels Beams Rounds Sheets Squares Flats Rebar Wire Mesh Black & Galvanized Pipe Anchor Bolts Plastic, Copper, Black, Galvanized Pipe

More information

Items Dimension(WxDxH) Max.Capacity Mounting P-FDB8 181X45X207mm 8 ports & splice Pole/Wall P-FDB16 220x80x300mm 16 ports & splice Pole/Wall

Items Dimension(WxDxH) Max.Capacity Mounting P-FDB8 181X45X207mm 8 ports & splice Pole/Wall P-FDB16 220x80x300mm 16 ports & splice Pole/Wall P-FDB General Features Available in 2 sizes, P-FDB8 and P-FDB16 Can accommodate 1x8 / 1X16 PLC splitters and 8 / 16 SC adapters Ultra violet resistant and waterproof Wall and pole mountable 2 inlet ports,

More information

dia. grit type R type S eblend surface conditioning disc

dia. grit type R type S eblend surface conditioning disc QUICK CHANGE Discs blend Mini E Quick Change Flap Discs The Mini E flap discs are manufactured using the best zirconia abrasive on a heavy cloth backing. Mini E discs features a quick change system using

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 00 01 10 Table of Contents DIVISION 00: PROCUREMENT AND CONTRACTING REQUIREMENTS 00 01 10 Table of Contents 06.17.2014 00 21 13 Instructions to Bidders 11.08.2013 00 22 13 Supplementary Instructions

More information

Index. E Expanded Metal Raised Flattened Grating... 93

Index. E Expanded Metal Raised Flattened Grating... 93 Index A Aluminum Angle... 0 Channel... 07 Flat... 0 Hexagon... 0 Pipe... 0 Plate... 99 Round... 0 Sheet... 9 Square... 0 Tread Plate (Floor/Diamond Plate)... 00 Tube... 09 Angle Aluminum... 0 Bar Size...

More information

Series P. Solvent Weld Sewer Fittings SDR 35. Solvent Weld Sewer Fittings SDR 35 P Series

Series P. Solvent Weld Sewer Fittings SDR 35. Solvent Weld Sewer Fittings SDR 35 P Series Solvent ITEM Weld INCHES NUMBER Sewer QTY Fittings QTY PRICE SDR ITEM 35 INCHES NUMBER QTY QTY PRICE Injection Molded in Sizes 3 12 Fabricated in Sizes 10 27 page 27 Phone: 586-781-2700 Toll Free: 1-800-232-5690

More information

PEREGRINE SERIES RETROFIT INSTALLATION GUIDE

PEREGRINE SERIES RETROFIT INSTALLATION GUIDE 06.05.17 HanleyLED H100W-PPS524V Spec Sheet SOLUTIONS THAT MAKE SENSE PEREGRINE SERIES RETROFIT INSTALLATION GUIDE Light Up New Markets Your Local Distributor: Grimco US www.grimco.com 800.542.9941 Canada

More information

SECTION [13200] FRAMED 2000 CLEANROOM WALL SYSTEM

SECTION [13200] FRAMED 2000 CLEANROOM WALL SYSTEM SECTION [13200] FRAMED 2000 CLEANROOM WALL SYSTEM SECTION 1 GENERAL 1.01 SECTION INCLUDES A. This Section specifies all requirements necessary to furnish and install a complete framed modular cleanroom

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

Current Control Houses

Current Control Houses Current Control Houses Building Shielding db Type Example 0 Transparent Wood 5 Poor Masonry 10 Moderate Concrete 20 Good Metal Siding 30 Metal All-Metal Current Control Houses Points of Entry Electrical

More information

C O M M E R C I A L. CALGARY EDMONTON LETHBRIDGE

C O M M E R C I A L.   CALGARY EDMONTON LETHBRIDGE C O M M E R C I A L www.alggin.com CALGARY EDMONTON LETHBRIDGE 4540-46th Ave. SE 12110-154 St. NW 1126-36 St. N (403) 252-0132 (780) 424-0132 (403) 320-8732 sales@alggin.com edmsales@alggin.com sales@alggin.com

More information

1.1. Cable Ties and Fixings Cable Ties Inside Serrated. UB-Series Cable Ties. Commercial Grade Cable Ties

1.1. Cable Ties and Fixings Cable Ties Inside Serrated. UB-Series Cable Ties. Commercial Grade Cable Ties 1.1 Cable Ties Inside Serrated UB-Series Cable Ties Commercial Grade Cable Ties Cable ties fit for all purposes manufactured in PA66 material. A range of commercial grade cable ties Available in black

More information

THD / THDH Face Mount Hangers

THD / THDH Face Mount Hangers EP angers T / T Face Mount angers T Medium capacity hanger for LVL, LSL, and PSL beams. T eavy capacity hanger for LVL, LSL, and PSL beams. Materials: See EP Face Mount angers charts, pages 147-148. Op

More information

Connection Solutions

Connection Solutions Connection Solutions Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 www.framecad.com FRAMECAD Connectors are designed for speed,

More information

POWER TOOL ACCESSORIES

POWER TOOL ACCESSORIES Professional SDS Plus Hammer Drills grade high performance SDS plus hammer drill bit range using the latest precision machining and carbide tip technology for increased penetration rates and more efficient

More information

Products Catalogue I. Mounting runners and components:

Products Catalogue I. Mounting runners and components: I. Mounting runners and components: 110111-R Mounting runner 40*40 mm M8 slot nut / M10 bolt length: 6.100 mm span width as per statics 110111-N 110112-R Mounting runner 40*40 mm with sideward screw channel

More information

8Rectangular Pin and Socket Connectors

8Rectangular Pin and Socket Connectors AMPLIMITE Connectors, Subminiature Series Connectors 109 (Continued) Introduction Product Facts Military qualified connectors conform to the latest amendments of MIL-DTL-24308 Industrial versions available

More information

A2000, LP2000 & CB2000

A2000, LP2000 & CB2000 A2000, LP2000 & CB2000 Dimensions Inches (Millimeters) A2000 & LP2000 A203504 LP201204 Specifications Rating: A2: 30A, 300V* LP2: 30A, 150V* CB2: 30A, 300V* Center Spacing: 0.375 or 3/8 (9.52mm) Wire Range:

More information

METRIC TO OPERATE OVERHEAD VALVES DUCTILE IRON STAINLESS STEEL ALUMINUM CARBON STEEL

METRIC TO OPERATE OVERHEAD VALVES DUCTILE IRON STAINLESS STEEL ALUMINUM CARBON STEEL METRIC TO OPERATE OVERHEAD VALVES DUCTILE IRON STAINLESS STEEL ALUMINUM CARBON STEEL CHAINWHEELS Page 2 Ductile Iron wheels Sprocket-Type, for use with Single Loop Cut Used to operate overhead valves from

More information

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2 document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com

More information

SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA)

SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA) TECHNICAL SPECIAL PROVISION FOR SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA) FINANCIAL PROJECT NO.: 428213-2-52-02 MARION COUNTY The official record of this Technical Special Provision is the

More information

SECTION MODEL 2577 INDOOR SCOREBOARD. A. Single-face electronic scoreboard and control console for indoor use.

SECTION MODEL 2577 INDOOR SCOREBOARD. A. Single-face electronic scoreboard and control console for indoor use. SECTION 116643 MODEL 2577 INDOOR SCOREBOARD PART 1 GENERAL 1.01 SECTION INCLUDES A. Single-face electronic scoreboard and control console for indoor use. 1.02 REFERENCES A. Standard for Electric Signs,

More information