1 Spring Test 17 due 06/14/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. The NEC defines cable as a cylindrical assembly composed of a conductor centered inside a metallic tube or shield, separated by a dielectric material, and usually covered by an insulating jacket. a. IP c. optical fiber e. UTP b. coaxial d. DSL 2. Unused openings in metal boxes, panels, and other enclosures shall. a. be open b. be closed to afford protection c. not be required to be closed if on the bottom of the enclosure d. not be required to be closed if the enclosure is in a dry location 3. The path to ground from circuits, equipment, and conductor enclosures shall. I. have sufficiently low impedance to limit the voltage to ground and to facilitate the operation of the circuit protective devices in the circuit II. be capable of safely carrying the maximum fault current likely to be imposed on it III. be permanent and electrically continuous a. I only b. II only c. III only d. I, II & III Figure Rated voltage must be applied to each transformer primary winding. Transformer Ratings: 240 x 480 to 120/240-volt 4. Which of the control transformers, shown in Figure , is correctly connected to operate the circuit? The motor circuit is 240-V, 3Ø and the coil rating is 120 V. a. II b. IV c. III d. I e. none of these 5. Which of the control transformers, shown in Figure , is correctly connected to operate the circuit? The motor circuit is 480-V, 3Ø and the coil rating is 240 volts. a. II b. IV c. III d. I e. none of these

2 6. Which of the control transformers, shown in Figure , is correctly connected to operate the circuit? The motor circuit is 480-V, 3Ø and the coil rating is 120 V. a. II b. IV c. III d. I e. none of these 7. All splices, joints, and free ends of conductors are required to be covered with an insulation the conductor. a. as thick as b. equivalent to c. thicker than d. larger than 8. The is the connection between the grounded circuit conductor and the equipment grounding conductor at the service. a. main bonding jumper d. grounding electrode conductor b. equipment bonding jumper e. supply side bonding jumper c. equipment grounding conductor 9. Where added to an existing installation, connection of a metal raceway to the equipment grounding conductor is not required if the raceway is used to protect 14/2 (no ground) Romex, is guarded against contact by persons, is less than feet in length, and is not within reach of ground or grounded metal. a. 6 b. 8 c. 10 d Given: A metal junction box has 27 cubic inches and contains a total of six 12 AWG wires. Additional conductors size 10 AWG need to be added in the box. No grounding conductors, devices or fittings are contained in the box. What is the MAXIMUM number of 10 AWG conductors that may be added to this box? a. 2 b. 5 c. 6 d Where a permanent barrier is installed in a pull box, each section is considered as. a. permanent barriers are not allowed c. 60% of the box b. a separate box d. the same box 12. Conduits mounted on indoor walls or in rooms that are hosed down frequently must between the mounting surface and the conduit. a. have a permanent 1 / 4 -inch air space b. be separated by insulated bushings c. be separated by noncombustible tubing d. none of these 13. Where NM cable is used, the cable assembly, including the sheath, shall extend into the box not less than. a. 1 / 2 " b. 3 / 4 " c. 1 / 4 " d. 1" 14. Unsupported runs of armored cable shall be permitted to be unsupported where the cable is not more than inches at terminals where flexibility is necessary. a. 24 b. 30 c. 36 d Where practicable, network-powered broadband communications cables on poles shall be located the electric light, power, Class 1, or non power-limited fire alarm circuit conductors and shall not be attached to a crossarm that carries electric light or power conductors. a. below b. above c. at the same height as 16. An insulated conductor that is intended for use as a grounded conductor, where contained within a flexible cord, shall be identified by or by other means permitted. I. a white or gray outer finish II. one or more white stripes on other than green insulation III. a green outer finish IV. a green outer finish with one or more yellow stripes

3 a. I only b. I or II only c. III only d. III or IV only 17. Conductors shall be unless otherwise provided in the Code. a. lead b. stranded c. copper d. aluminum 18. Type, a flat cable assembly, is an assembly of parallel conductors formed integrally with an insulating material web specifically designed for field installation in surface metal raceway. a. FCC b. FC c. TC d. SNM 19. plugs driven into holes in masonry, concrete, plaster, or similar materials shall not be used. a. Metal b. Plastic c. Leather d. Wooden 20. Not more than one conductor shall be connected to the grounding electrode by a single clamp or fitting unless the clamp or fitting is. a. cast bronze or brass d. all of these b. listed for multiple conductors e. none of these c " in thickness 21. optical fiber cables contain optical fibers and current-carrying electrical conductors. a. Composite b. Nonconductive c. Conductive 22. A(n) branch-circuit supplies two or more receptacles or outlets for lighting and appliances. a. appliance c. individual e. general purpose b. multiwire d. lighting 23. In a partially completed building, an electrician plugs into a receptacle with an extension cord. To comply with the NEC, the electrician must. a. be sure that the receptacle has GFCI protection b. have permission from the occupants of the building c. be sure the cord has twist-lock connections d. use a minimum size cord of 12/4 AWG 24. Bonding all piping and within the premises will provide additional safety. a. water heaters b. pumps c. metal air ducts d. none of these 25. Unless identified for use in the operating environment, no conductors or equipment shall be located in having a deteriorating effect on the conductors or equipment. I. damp or wet locations II. where exposed to gases, fumes, vapors, liquids, or other agents a. I only b. both I and II c. II only d. neither I nor II 26. Before you energize a motor for the first time, you want to make certain that it has the proper voltage. You check the voltage at the disconnect for the motor and find that the voltage from AØ to ground is 120 volts, BØ to ground is 208 volts, and CØ to ground is 120 volts. This circuit originates in a panel that is supplied by a system. a. 277/480-volt, 3Ø, 4 wire d. 120/208-volt, 3Ø, 4 wire b. 480-volt, 3Ø, 3 wire e. 120/240-volt, 3Ø, 4 wire c. 240-volt, 3Ø, 3 wire 27. According to the NEC, which of the following statements is true about installing listed or labeled equipment? a. The equipment may be installed in whatever manner the contractor determines best. b. The equipment shall be installed in accordance with the instructions. c. The equipment only needs to be listed or labeled if it is installed in an industrial

4 environment. d. The equipment may be subject to listed or labeled equipment if it is determined to be acceptable by the contractor. 28. When UF cable is supplied from a GFCI-protected, residential branch circuit that is rated 15 amps at 115 volts, the minimum burial depth is inches when the cable is installed underground to an outdoor post light. a. 24 b. 18 c. 12 d Operation of equipment in excess of normal, full-load rating, or of a conductor in excess of rated ampacity that, when it persists for a sufficient length of time, would cause damage or dangerous overheating, is called. I. a short circuit II. a ground fault III. an overload a. I & II only c. I & III only e. I, II & III b. I only d. III only 30. Conductors of AC or DC circuits rated 600 volts or less shall be permitted to occupy the same conduit if. a. all conductors shall have an insulation rating equal to the maximum circuit voltage applied to any conductor in the conduit b. all conductors have a 600-volt insulation rating c. a dividing barrier in the raceway separates the AC and DC circuit conductors d. none of these; AC and DC conductors are not permitted in the same raceway 31. Which of the following is not true concerning temporary wiring? a. All lamps shall be protected by a suitable fixture or guard. b. Handle ties are permitted to disconnect multiwire branch circuits. c. Tests shall be performed on cords and receptacles and plugs for correct attachment to the equipment grounding conductor. d. Temporary power for Christmas decorative lighting shall not exceed 60 days. 32. A type of surface, flush, or freestanding raceway, designed to hold conductors and receptacles, assembled in the field or at the factory is called a. a. busway c. wireway e. multioutlet assembly b. cablebus d. cable tray 33. For a 1000-volt system, the distance between each cable or conductor entry inside the box and the opposite wall of the box shall not be less than times the outside diameter, over sheath, of the largest cable or conductor. a. 6 b. 18 c. 36 d Which of the following may not be used in damp or wet locations? a. type AC armored cable c. electrical metal tubing b. open wiring d. rigid metal conduit 35. The use of is prohibited for connection of a grounding conductor to equipment. a. sheet metal screws c. clamps b. pressure connectors d. lugs 36. What is the minimum thickness of metal for a 6" 4" 3 1 / 4 " box? a..0625" b..0747" c. 15 SMG d. 16 SMG 37. The connection point between the facilities of the serving utility and the premises wiring is called the. a. service point c. metering point

5 b. service equipment d. main disconnect 38. In walls or ceilings of noncombustible material, boxes shall be installed so that the front edge of the box will not be set back of the finished surface more than inch(es). a..125 b..5 c d..25 e A receptacle mounted more than eight feet above the finished floor is considered. a. ceiling mounted c. isolated b. not readily accessible d. inaccessible 40. Which answer best completes the following sentence describing the Code requirements for the use of short-radius, capped elbow conduit bodies containing conductors smaller than 6 AWG? Capped elbow type conduit bodies. a. are not permitted by Code b. may be used to enable the installation of the raceway c. may contain devices d. may contain splices and taps 41. Readily accessible means capable of being reached quickly for operation, inspection, or service without. a. opening locked doors b. having to climb over or remove obstacles c. having to use a portable ladder d. any of these 42. All conductors of a circuit are required to. I. be in the same raceway II. be installed in close proximity in the same trench III. be the same size a. III only b. I only c. I, II & III d. I & II only 43. Wiring methods installed behind panels that allow access, such as the space above a dropped ceiling, are required to be according to their applicable articles. a. supported c. in a metal raceway b. painted d. all of these 44. A device intended to open under short circuit or ground fault is selected based on its rating. a. operating b. interrupting c. ampacity d. temperature 45. covers and plates shall be permitted with nonmetallic boxes. I. Nonmetallic II. Metal a. I only b. II only c. either I or II d. neither I or II 46. Underground cable installed under a building shall be in a that is extended beyond the outside walls of the building. a. sleeve b. duct bank c. gutter d. raceway 47. An electric circuit that controls another electric circuit through a relay is referred to as a(n) circuit. a. automatic c. remote-control e. equipment b. motor control d. individual 48. Induction heating coils that operate or may operate at a voltage greater than 30 volts AC shall be to protect personnel in the area. I. isolated II. made inaccessible by location III. enclosed in a nonmetallic enclosure IV. enclosed in a split metallic enclosure

6 a. I or III only c. I, II, or IV only b. I, II, or III only d. I, II, III, or IV 49. The MAXIMUM number of 10 AWG conductors permitted in a 4" 1 1/4" octagon metal junction box is. a. 2 b. 4 c. 5 d Equipment is considered to be accessible when. a. it is not guarded by locked doors c. it is not equipped with a locking cover b. a ladder is required to reach it d. both a and b 51. To settle a disagreement between an inspector and a contractor foreman, the would have the final say. a. local authority having jurisdiction c. IBEW b. local electrical board d. engineer 52. Voltage between the hot (ungrounded) conductors on FCC cable shall not exceed volts. a. 50 b. 300 c. 150 d. 600

7 Spring Test 17 due 06/14/2013 Answer Section MULTIPLE CHOICE 1. ANS: B 2011 NEC: PTS: 1 REF: 2011 NEC: OBJ: 434 NEC Worksheet NAT: 434 NEC ABank 2. ANS: B 2011 NEC: (A) PTS: 1 REF: 2011 NEC: (A) OBJ: 422 NEC Worksheet 3. ANS: D 2011 NEC: 250.4(B) PTS: 1 REF: 2011 NEC: 250.4(B) OBJ: 423 NEC Worksheet NAT: 423 NEC ABank 4. ANS: A Ugly s/ferm s PTS: 1 REF: Gen Knowledge OBJ: Obj Worksheet NAT: Obj ABank 5. ANS: C Ugly s/ferm s PTS: 1 REF: Gen Knowledge OBJ: Obj Worksheet NAT: Obj ABank 6. ANS: B Ugly s/ferm s PTS: 1 REF: Gen Knowledge NAT: Obj ABank 7. ANS: B 2011 NEC: (B) PTS: 1 REF: 2011 NEC: (B) OBJ: 422 NEC Worksheet 8. ANS: A Defn: Bonding Jumper-Main PTS: 1 REF: OBJ: Obj Worksheet NAT: Obj ABank 9. ANS: D 2011 NEC: Exc 1 PTS: 1 REF: 2011 NEC: Exc 1 OBJ: 423 NEC Worksheet NAT: 423 NEC ABank 10. ANS: B

8 2011 NEC: T (B) PTS: 1 REF: 2011 NEC: T (B) OBJ: Obj Worksheet NAT: Obj ABank 11. ANS: B 2011 NEC: (D) PTS: 1 REF: 2011 NEC: (D) NAT: Obj ABank 12. ANS: A 2011 NEC: 300.6(D) PTS: 1 REF: 2011 NEC: 300.6(D) OBJ: Obj Worksheet NAT: Obj ABank 13. ANS: C 2011 NEC: (C) PTS: 1 REF: 2011 NEC: (C) NAT: Obj ABank 14. ANS: A 2011 NEC: (D)(2) PTS: 1 REF: 2011 NEC: (D)(2) NAT: Obj ABank 15. ANS: A 2011 NEC: (A)(1) PTS: 1 REF: 2011 NEC: (A)(1) OBJ: 434 NEC Worksheet NAT: 434 NEC ABank 16. ANS: B 2011 NEC: 200.6(C) PTS: 1 REF: 2011 NEC: 200.6(C) OBJ: Obj Worksheet NAT: Obj ABank 17. ANS: C 2011 NEC: PTS: 1 REF: 2011 NEC: OBJ: 422 NEC Worksheet 18. ANS: B 2011 NEC: PTS: 1 REF: 2011 NEC: OBJ: Obj Worksheet NAT: Obj ABank 19. ANS: D 2011 NEC: (A) PTS: 1 REF: 2011 NEC: (A) OBJ: 422 NEC Worksheet 20. ANS: B 2011 NEC: PTS: 1 REF: 2011 NEC: OBJ: 423 NEC Worksheet NAT: 423 NEC ABank 21. ANS: A

9 2011 NEC: PTS: 1 REF: 2011 NEC: OBJ: 434 NEC Worksheet NAT: 434 NEC ABank 22. ANS: E Defn: Branch Circuit-General Purpose PTS: 1 REF: NAT: Obj ABank 23. ANS: A 2011 NEC: 590.6(A) PTS: 1 REF: 2011 NEC: 590.6(A) OBJ: 428 NEC Worksheet NAT: 428 NEC ABank 24. ANS: C 2011 NEC: (B) I-Note No. 1 PTS: 1 REF: 2011 NEC: (B) I-Note No. 1 OBJ: 423 NEC Worksheet NAT: 423 NEC ABank 25. ANS: B 2011 NEC: PTS: 1 REF: 2011 NEC: OBJ: 422 NEC Worksheet 26. ANS: E Ferm s/ugly s PTS: 1 REF: Gen Knowledge NAT: Obj ABank TOP: Voltage System ID 27. ANS: B 2011 NEC: 110.3(B) PTS: 1 REF: 2011 NEC: 110.3(B) 28. ANS: C 2011 NEC: T ;Col. 4 PTS: 1 REF: 2011 NEC: T ;Col. 4 NAT: Obj ABank 29. ANS: D Defn: Overload PTS: 1 REF: OBJ: Obj Worksheet NAT: Obj ABank 30. ANS: A 2011 NEC: 300.3(C)(1) PTS: 1 REF: 2011 NEC: 300.3(C)(1) OBJ: Obj Worksheet NAT: Obj ABank 31. ANS: D 2011 NEC: 590.3(B) PTS: 1 REF: 2011 NEC: 590.3(B) NAT: 428 NEC ABank

10 32. ANS: E Defn: Multioutlet Assembly PTS: 1 REF: OBJ: Obj Worksheet NAT: Obj ABank 33. ANS: C 2011 NEC: (B)(1) PTS: 1 REF: 2011 NEC: (B)(1) OBJ: Obj Worksheet NAT: Obj ABank TOP: Box Fill 34. ANS: A 2011 NEC: (4) PTS: 1 REF: 2011 NEC: (4) NAT: Obj ABank 35. ANS: A 2011 NEC: PTS: 1 REF: 2011 NEC: OBJ: 423 NEC Worksheet NAT: 423 NEC ABank 36. ANS: A 2011 NEC: (B) PTS: 1 REF: 2011 NEC: (B) OBJ: Obj Worksheet NAT: Obj ABank 37. ANS: A Defn: Service Point PTS: 1 REF: NAT: Obj ABank 38. ANS: D 2011 NEC: PTS: 1 REF: 2011 NEC: OBJ: Obj Worksheet NAT: Obj ABank 39. ANS: B Defn: Accessible-Readily PTS: 1 REF: NAT: Obj ABank 40. ANS: B 2011 NEC: (C)(3) PTS: 1 REF: 2011 NEC: (C)(3) OBJ: Obj Worksheet NAT: Obj ABank TOP: Box Fill 41. ANS: D Defn: Accessible-Readily PTS: 1 REF: NAT: Obj ABank 42. ANS: D 2011 NEC: 300.3(B)

11 PTS: 1 REF: 2011 NEC: 300.3(B) NAT: Obj ABank 43. ANS: A 2011 NEC: 300.4(C) PTS: 1 REF: 2011 NEC: 300.4(C) OBJ: Obj Worksheet NAT: Obj ABank 44. ANS: B 2011 NEC: PTS: 1 REF: 2011 NEC: OBJ: 422 NEC Worksheet 45. ANS: C 2011 NEC: (A) PTS: 1 REF: 2011 NEC: (A) NAT: Obj ABank 46. ANS: D 2011 NEC: 300.5(C) PTS: 1 REF: 2011 NEC: 300.5(C) OBJ: Obj Worksheet NAT: Obj ABank 47. ANS: C Defn: Remote-Control Circuit PTS: 1 REF: OBJ: Obj Worksheet NAT: Obj ABank 48. ANS: D 2011 NEC: PTS: 1 REF: 2011 NEC: OBJ: Obj 429 NEC Worksheet NAT: 429 NEC ABank 49. ANS: C 2011 NEC: T (A) PTS: 1 REF: 2011 NEC: T (A) NAT: Obj ABank TOP: Box Fill 50. ANS: A Defn: Accessible (as applied to equipment) PTS: 1 REF: NAT: Obj ABank 51. ANS: A 2011 NEC: 90.4 PTS: 1 REF: 2011 NEC: 90.4 NAT: Obj ABank 52. ANS: B 2011 NEC: (B)(1) PTS: 1 REF: 2011 NEC: (B)(1) OBJ: Obj Worksheet NAT: Obj ABank

Spring Test 9 due 05/11/2013

Spring Test 9 due 05/11/2013 Spring Test 9 due 05/11/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. A grounding electrode is. a. a solid conductor b. a circuit conductor that

More information

Spring Test 13 due 06/14/2013

Spring Test 13 due 06/14/2013 Spring Test 13 due 06/14/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. The power supply to the mobile home shall be a feeder assembly consisting

More information

Spring Test 16 due 06/14/2013

Spring Test 16 due 06/14/2013 Spring Test 16 due 06/14/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. Figure 234.142 1. Refer to the information shown in Figure 234.142. Motor 1

More information

Fall Test 21 due 12/11/2012

Fall Test 21 due 12/11/2012 Fall Test 21 due 12/11/2012 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Emergency system transfer equipment, including automatic transfer switches,

More information

Spring Test 5 due 4/26/2013

Spring Test 5 due 4/26/2013 Spring Test 5 due 4/26/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Where fixed multioutlet assemblies are employed, each feet or fraction thereof

More information

Electrical Components and Equipment for General Use Self Inspection Checklist

Electrical Components and Equipment for General Use Self Inspection Checklist Name of School: Optional Information Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Electrical Components and Equipment for General Use Self Inspection Checklist Guidelines:

More information

Meter Enclosure and Equipment Standards

Meter Enclosure and Equipment Standards Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable

More information

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D. Electrical Integration of PV Systems Ridha Hamidi, Ph.D. 1 Many articles in the NEC are applicable to the electrical integration of a PV system, particularly Article 690. 2 The NEC defines the various

More information

Entry Level Assessment Blueprint Electrical Occupations

Entry Level Assessment Blueprint Electrical Occupations Entry Level Assessment Blueprint Electrical Occupations Test Code: 3029 / Version: 01 Specific Competencies and Skills Tested in this Assessment: Safety Apply shop safety rules and ergonomics Explain fire

More information

Computer Network Design Guide Existing Systems 1 / 6

Computer Network Design Guide Existing Systems 1 / 6 COMPUTER NETWORK DESIGN GUIDELINE FOR EXISTING SYSTEMS DOCUMENT NUMBER: 16765 APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL DATE OF ISSUE: 11-27-06 - First Issued NOTES: The attached guideline should

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 5 APPR:LWB:DBP:07-31-13

More information

Solar Combiner Enclosure

Solar Combiner Enclosure Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the

More information

UNDERCARPET CABLING SYSTEM For Power and Communications

UNDERCARPET CABLING SYSTEM For Power and Communications UNDERCARPET CABLING SYSTEM For Power and Communications Linking Everything Together Power, Voice, and Data December 5, 2007 Undercarpet Cabling System Overview What is Undercarpet Cabling? Primary Applications

More information

NEC 2008 Code Changes Top 20 Revisions. By: Rafi Wartan, PE, LEED AP

NEC 2008 Code Changes Top 20 Revisions. By: Rafi Wartan, PE, LEED AP NEC 2008 Code Changes Top 20 Revisions By: Rafi Wartan, PE, LEED AP #1 Article 210.4 MULTIWIRE BRANCH CIRCUITS The rule on simultaneous disconnecting means requirements for multiwire branch circuits was

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist TES A. Roads-Service, Lanes Common Items Trails and service roads provide adequate access to buildings for maintenance B. Testing Results-provided to the local government construction representative Data

More information

Emery County Senior Center Green River 06/07

Emery County Senior Center Green River 06/07 SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

R-LB R-LX Series Installation, Operation & Maintenance Manual

R-LB R-LX Series Installation, Operation & Maintenance Manual Installation, Operation & Maintenance Manual WARNINGS Safety First Hazardous Voltage & Shock Hazard Only qualified licensed electricians should install or service SPDs Hazardous voltages exist within SPDs

More information

Introduction to the Inspection Checklist for Rooftop Solar Photovoltaic (PV) Systems in Goshen, IN

Introduction to the Inspection Checklist for Rooftop Solar Photovoltaic (PV) Systems in Goshen, IN Introduction to the Inspection Checklist for Rooftop Solar Photovoltaic (PV) Systems in Goshen, IN This Inspection Checklist for Rooftop Photovoltaic (PV) Systems is based on the Model Inspection Checklist

More information

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death. Installation/Operation Manual TABLE OF CONTENTS Page UNPACKING AND INSTALLATION Unpacking and Preliminary Inspection...2, 3 Model Number...9 LOCATION CONSIDERATIONS Environment, Equipment Performance,

More information

SECTION WIRING DEVICES

SECTION WIRING DEVICES SECTION 16141 WIRING DEVICES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...

More information

IEC H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and

IEC H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and IEC 60309 H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and amperage to prevent interchangeability of voltages Watertight

More information

SECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 26 27 26 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

The six major components of a structured wiring system are:

The six major components of a structured wiring system are: OBJECTIVES 1. Describe various ANSI/TIA/EIA standards for commercial buildings and residential settings. 2. Discuss the specific Technical Systems Bulletins that can affect telecommunications installations.

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits Course Details Date: January 28 January 31, 2019 Time: 8:00 A.M. - 4:30 P.M. Capacity: 12 attendees Provider: National Technology

More information

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM 1993 SPECIFICATIONS CSJ 1685-05-068, ETC. & 1685-02-042 1.0 DESCRIPTION SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM THIS ITEM DESCRIBES THE OPERATION AND INSTALLATION OF AN ARTERIAL

More information

SECTION SWITCHGEAR

SECTION SWITCHGEAR SECTION 26 23 13 SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

SECTION WIRING DEVICES

SECTION WIRING DEVICES PART 1 - GENERAL... 1 1.1 RELATED DOCUMENTS... 1 1.2 SUMMARY... 1 1.3 DEFINITIONS... 1 1.4 REFERENCES... 2 1.5 SUBMITTALS... 2 1.6 QUALITY ASSURANCE... 2 1.7 COORDINATION... 2 PART 2 - PRODUCTS... 2 2.1

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:

More information

ONE GANG WEATHERPROOF OUTLET BOXES - DIE CAST METAL BWF Product Benefits & Features B-5V DB-5V B5-2V. Applications

ONE GANG WEATHERPROOF OUTLET BOXES - DIE CAST METAL BWF Product Benefits & Features B-5V DB-5V B5-2V. Applications For over 50 years, BWF/M. Stephens has been a leader in the die casting industry. With the full line of outdoor weatherproof products, BWF/M. Stephens is committed to offering the high quality and customer

More information

Bulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010

Bulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010 Ontario Electrical Safety Code - Bulletins 50-1-0 Bulletin 50-1-0 Installation of Solar Photovoltaic Systems Section 50; Rules: 84-020, 84-024, 84-030; Tables 11 and 19 Issued July 2010 Scope (1) Introduction

More information

Testing for safe and efficient branch circuits

Testing for safe and efficient branch circuits Testing for safe and efficient branch circuits Written by Chad Reynolds, Product Manager, IDEAL Test and Measurement Division Branch Circuit Testing Branch circuit wiring and testing practices are primarily

More information

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS - For use with CONTROLTrack System Only When installing or using this track system, basic safety precautions should always be

More information

Installation Instructions

Installation Instructions 50ES, 50EZ, 50GL, 50GS, 50GX, 50JS, 50JX, 50JZ, 50SD, 50SZ, 50VL, 50VT, 50XP, 50XZ 601A, 602A, 602B, 604A, 604B, 604D, 607C, 701A, 702A, 702B, 704A, 704B, 704D, 707C PA1P, PA2P, PA3P, PH1P, PH2P, PH3P

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

M215 (M215-60) Safety

M215 (M215-60) Safety M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 6 APPR:MDW:JVG:06-08-18

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215

More information

NECA 130. Standard for Installing and Maintaining Wiring Devices. Industry Review Draft (Date TBD)

NECA 130. Standard for Installing and Maintaining Wiring Devices. Industry Review Draft (Date TBD) NECA 130 Standard for Installing and Maintaining Wiring Devices Industry Review Draft (Date TBD) National Electrical Installation Standards, NEIS, and the NEIS logo are trademarks of the National Electrical

More information

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT MODEL INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT A. GENERAL. The Federal Model is a solid-state

More information

FDS / FDS-R / FDS-PS

FDS / FDS-R / FDS-PS FDS / FDS-R / FDS-PS USER MANUAL For use with 120V 60Hz input. Output is 120V 60Hz at 5amps 600W MAX. switched. ETL LISTED Conforms to UL STD 1241 3091594 79-15167-00 REV. A www.fiberstars.com Page 1 of

More information

3M Indoor Protected Building Entrance Terminal 4788V-QCS Series

3M Indoor Protected Building Entrance Terminal 4788V-QCS Series The Network of Networks. 3M Indoor Protected Building Entrance Terminal 4788V-QCS Series with 3M Quick Connect System (QCS) 2811 Dry Flame Retardant Block for Field-Terminated Building Cables Instructions

More information

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1993 Specifications CSJ s 0924-06-221,etc. & 0924-06-223 SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1. Description. This specification describes the minimum acceptable requirements for a weatherproof

More information

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Series Amp Pad Mount Quick Connect Input and Output Power Panels Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase

More information

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series

3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series 3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series with 3M Quick Connect System (QCS) 2811 Dry Flame-Retardant Block and RJ-11 Test Ports Instructions Underwriters Laboratories (UL 348X)

More information

Blueprint Drawings & Wiring Diagrams. for branch circuits

Blueprint Drawings & Wiring Diagrams. for branch circuits Blueprint Drawings & Wiring Diagrams for branch circuits Blueprint Symbols Wiring Diagram Symbols 2 Table of Contents Single Pole Switching p. 5-11 Three-way Switching p. 12-18 Four-way Switching p.19-25

More information

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE / 2 Ground Power Modules And Accessories For Healthcare Facilities Technical Bulletin NAE2092320 / 10.2011 Ground Power Modules Hospital grade outlet modules Introduction BENDER series GPM ground and power

More information

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO Cabling Standards Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO 1. Purpose CABLING STANDARDS This technical note

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS SECTION 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Nameplates. 2. Labels. 3. Wire markers. 4. Conduit markers. 5. Underground Warning Tape. 6. Lockout

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: Members of the NEC-Code Making Panel 3 FROM: Jean

More information

Cable TV, Broadband, Telephone, and Security

Cable TV, Broadband, Telephone, and Security Chapter 7 Cable TV, Broadband, Telephone, and Security Because of the increasingly widespread use of communications and security systems over the past two decades, electricians have been called upon to

More information

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

More information

Quick Start Guide TS A

Quick Start Guide TS A Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer

More information

More Questions from Inspectors Numerous PV Systems Pose Issues

More Questions from Inspectors Numerous PV Systems Pose Issues Perspectives on PV More Questions from Inspectors Numerous PV Systems Pose Issues by John Wiles 76 IAEI NEWS March. April 2012 www.iaei.org Photovoltaic (PV) systems prices continue to drop and inspectors

More information

ELECTRICAL SAFETY INSPECTION REPORT

ELECTRICAL SAFETY INSPECTION REPORT ELECTRICAL SAFETY INSPECTION REPORT CHITTAGONG FASHION WEAR LTD. SOUTH HALISHAHAR, CHITTAGONG, BANGLADESH Factory List: 1. Chittagong Fashion Wear Ltd. 2. H & W Apparels Inspected on May 5, 2014 SUMMARY

More information

Gadget Freak Case #238: Controller Adjusts Garage Lights Build Instructions

Gadget Freak Case #238: Controller Adjusts Garage Lights Build Instructions Gadget Freak Case #238: Controller Adjusts Garage Lights Build Instructions The schematic diagram shows the main garage-light switch (SW1) that turns on both fluorescent lamps, Lamp 1 and Lamp 2. Only

More information

Stalking the Elusive and Somewhat Strange PV System

Stalking the Elusive and Somewhat Strange PV System A series of articles on photovoltaic (PV) power systems and the National Electrical Code by John Wiles PERSPECTIVES ON PV Stalking the Elusive and Somewhat Strange PV System Photo 1. Framed PV modules

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Wired Remote Controller 7 Day Programmable Ductless Systems KSACN0401AAA (High Wall Models) KSACN0501AAA (Ducted/Cassette Models) INSTALLATION INSTRUCTIONS NOTE: Read the entire instruction manual before

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs) ga GE Digital Energy Power Quality INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs) 2020005003 (12/09) Page 1 of 18

More information

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide *619751* P/N 619751 - Rev B IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS

More information

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 Supersedes 6/2015 Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 XXCFXXX10-DIN Contents Description Page 1.0 Setup...2 1.1 Before Installation...2 1.2 Installation...3 For AC Applications...3

More information

SECTION WIRING DEVICES

SECTION WIRING DEVICES SECTION 26 27 26 WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Receptacles, receptacles with integral GFCI, and associated device plates. 2. Twist-locking receptacles.

More information

Installation Instructions

Installation Instructions Please read all instructions before installing RS-350 PIR Dual Relay Universal Application Wall Switch Vacancy Sensor with Manual ON/OFF Lens Lighted Switch ON/OFF button for Relay 1 ON/OFF button for

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions.

More information

Current Control Houses

Current Control Houses Current Control Houses Building Shielding db Type Example 0 Transparent Wood 5 Poor Masonry 10 Moderate Concrete 20 Good Metal Siding 30 Metal All-Metal Current Control Houses Points of Entry Electrical

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

M250 (M LL) Safety

M250 (M LL) Safety M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Date: Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of stations meets DD 9, applicable

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 00 01 10 Table of Contents DIVISION 00: PROCUREMENT AND CONTRACTING REQUIREMENTS 00 01 10 Table of Contents 06.17.2014 00 21 13 Instructions to Bidders 11.08.2013 00 22 13 Supplementary Instructions

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual APC 2X Series Hardwire Products PMP2X-A PMF2X-A PMG2X-A PMH2X-A APC hardwired products are designed to provide specification-grade performance at the service entrance,

More information

PoP ROOM: INSIDE AND OUTSIDE PLANT RULES & REGULATIONS

PoP ROOM: INSIDE AND OUTSIDE PLANT RULES & REGULATIONS PoP ROOM: INSIDE AND OUTSIDE PLANT RULES & REGULATIONS Version 14 November 19, 2014 Digital Realty Table of Contents INTRODUCTION... 3 ACCESS TO THE POP ROOMS, ISP & OSP... 3 PoP- MoP Forms... 3 Who must

More information

ft Aspen Fir Item # Commercial ITEM Lights

ft Aspen Fir Item # Commercial ITEM Lights 7.57.5 ft Aspen Fir Item #142027 Commercial ITEM Lights PARTS LIST A. BOTTOM B. LOWER MIDDLE C. UPPER MIDDLE D. TOP E. TREE STAND NUMBER OF PERSONS RECOMMENDED FOR ASSEMBLY: 2 SKU 142027 7.5 ASPEN FIR

More information

Flap Barrier User Manual

Flap Barrier User Manual Flap Barrier User Manual Applicable Models: FBL 4000 / 5000 Version: 1.0 Date: Mar. 2017 Contents Chapter 1 Overview... 1 1.1 Product Model and Appearance... 1 1.2 Features... 2 1.3 Technical Parameters...

More information

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL Model name: BMS-LSV6UL INTELLIGENT SERVER Thank you very much for purchasing this TOSHIBA INTELLIGENT SERVER. Please read this manual carefully beforehand for proper installation of the SERVER. NOTE This

More information

Page 1 of 149 First Revision No. 50-NFPA 79-2012 [ Global Input ] Delete the parenthetical terms used to describe IEC terms that follow terms used in NFPA 79 such as "protective bonding". Add information

More information

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel. LX Breaker Control Panels Installation and Setup Procedure Hubbell Building Automation, Inc. 9601 Dessau Road Building One Suite 100 Austin, Texas 78754 512-450-1100 512-450-1215 Fax www.hubbell-automation.com

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC 5-, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC 5-,

More information

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section. SECTION 16420 - ELECTRICAL EQUIPMENT PART 1 - GENERAL 1.01 RELATED DOCUMENTS The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

Outdoor Risk and Equipment Protection

Outdoor Risk and Equipment Protection Outdoor Risk and Equipment Protection The proper use of surge suppressors, lightening arrestors, and weatherproof enclosures are critical protection measures for all outdoor wireless and IP video devices.

More information

The purpose of this document is to specify the power requirements for Core Health and Fitness LLC equipment.

The purpose of this document is to specify the power requirements for Core Health and Fitness LLC equipment. Power Requirements Applies to: All Machines The purpose of this document is to specify the power requirements for Core Health and Fitness LLC equipment. Latest Rev. Attention: Obtain the assistance of

More information

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters Yellow Section Capacitor Sockets and Monitors, Temporary Service Adapters, Quick Set/Gen Set, Temporary Load Center, TSA, Transformer Load Management CAPACITOR CONTROLLER SOCKET Four - Six Jaws Wire Lugs

More information

Standards Update Notice (SUN) Issued: July 28, 2017

Standards Update Notice (SUN) Issued: July 28, 2017 Standard Information Standard Number: CSA C22.2 No. 107.1 Standard Name: Power conversion equipment Standard Edition and Issue Date: 4 th Edition Dated June 2016 Date of Issue: June 2016 Date of Previous

More information

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter Install Guide Revision C (12/18) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Revision C (12/18) Turn off all power supplying equipment

More information