Spring Test 9 due 05/11/2013

Size: px
Start display at page:

Download "Spring Test 9 due 05/11/2013"

Transcription

1 Spring Test 9 due 05/11/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. A grounding electrode is. a. a solid conductor b. a circuit conductor that is intentionally grounded c. a conducting object through which a direct connection to earth is established d. none of these 2. A separate portion of a conduit or tubing system that provides access through a removable cover is called. a. an FS box c. a covered conductor b. guarded d. a conduit body 3. A single-family dwelling has a demand load of 70 amperes and is supplied with a 120/240 volt, 3-wire service with a main overcurrent device rating not less than: a. 70 amperes. b. 80 amperes. c. 90 amperes. d. 100 amperes. e. 125 amperes. 4. Using standard load calculations, the feeder demand factor for five household clothes dryers is percent. a. 100 b. 85 c. 75 d The following bends are made in a run of RMC or EMT between a 4-square box and a pull point (an LB for example): one 10º box offset + one 45º 3-pt saddle + two 30º offsets + one 60º kick. Is this a violation of the NEC? a. No b. Yes 6. A branch circuit is. a. the wiring that runs out to the utility b. the overcurrent that supplies power c. the circuit conductors between the final overcurrent device and the outlets d. a device designed to open and close a circuit by nonautomatic means 7. A grounded conductor is. a. a solid conductor b. a circuit conductor that is intentionally grounded c. a device that establishes an electrical connection to the earth d. none of these 8. According to the Table Notes in Chapter 9 in the NEC, any section of EMT, rigid metal conduit, IMC, etc that has a length of inches or less is considered to be a nipple. a. 36 b. 18 c. 12 d. 30 e. 24

2 9. A central air-conditioning unit is rated single-phase, 240 volts and has a branch circuit selection current of 28 amperes marked on the nameplate. If the air-conditioner is installed in a single-family dwelling using copper nonmetallic-sheathed cable, Type NM-B, the minimum size permitted is: a. 14 AWG. b. 12 AWG. c. 10 AWG. d. 8 AWG. e. 6 AWG. 10. A feeder supplying two 4kW wall mounted ovens a a 5kW counter mounted cooktop in a dwelling unit shall have a minimum demand of_kw. a. 8.4 c b. 8.8 d. none of these 11. The minimum bending radius permitted by the NEC for trade size 1 conduit is inches. a. 4 1 / 2 b. 7 1 / 4 c. 5 3 / 4 d. 8 1 / 4 e in the NEC covers all types of wiring methods and materials, including conduit. a. Article 100 b. Chapter 2 c. Chapter 3 d. Chapter Arc Fault Circuit Interrupter protection is not required in residences: a. for 120v receptacles in bathrooms, kitchens, and laundry rooms. b. on circuits that feed remote controlled ceiling fans. c. where EMT is the wiring method. d. as long as there is also GFCI protection. e. on multi-wire branch circuits. 14. In all dwelling units, a general use receptacle is not required: a. to serve wall counter spaces over 12 d. in an alcove more than 2 deep and 3 inches wide. feet long. b. on a 4 by 6 balcony with no stairway e. a receptacle is required in all of these to the ground. locations. c. in an unfinished basement. 15. According to the NEC Table Notes in Chapter 9, any nipple shall be permitted to be filled to percent. a. 20 b. 60 c. 40 d The NEC definition of voltage is. a. A force of power which will be offset buy the greater conductivity b. The greatest root-mean-square difference of potential between any two conductors of the circuit c. Electrons flowing though one point in one second d. The resulting power used by any equipment 17. What provision is required for convenient and practical use of electrical power at a 30 foot long show window in a retail commercial tenant space? a. three receptacles located within 18 d. three receptacles in the suspended inches of the top of the window. ceiling above the window. b. a 1500 watt receptacle on a sign e. one receptacle on each side of the

3 circuit. c. two receptacles. show window. 18. The XO terminal of a separately derived system or transformer is referred to by the 2011 NEC as the: a. neutral conductor. d. grounded service entrance conductor. b. grounding electrode point. e. white terminal. c. neutral point. 19. Oregon allows for listed and labeled electrical products to be installed because they are considered the same asas allowed for in the Oregon Revised Statute a. a NRTL approved electrical products c. an approved electrical product b. a certified electrical product d. all of these 20. A multioutlet assembly. a. consists of utility panels, raceways, and associated service boxes b. is the equipment used in conjunction with servicing commercial feeders c. is the equipment that utilizes electric energy for heating, lighting, or similar purposes d. is a type of surface, flush, or free standing raceway designed to hold conductors 21. A general supervising electrician in Oregon is authorized to design an electrical installation: a. of any photo voltaic system. d. in all commercial and residential applications. b. in locations deemed by the fire e. in manufacturing plants. marshal as hazardous. c. for customers of an electrical contractor that continuously employs him. 22. EMT bends shall be made so that the tubing is not damaged and the internal diameter of the tubing is not effectively reduced. This is a requirement of the NEC in. a b (A) c (A) d e. none of these 23. Flexible Metal Conduit used to connect equipment where flexibility is required after installation: a. must utilize stranded conductors. d. provides adequate grounding if listed fittings are used. b. requires the installation of an equipment grounding conductor. c. cannot be longer than 1.4 meters, (41/2 ft.). e. shall only be used in trade sizes larger than 11/4 inches 24. The minimum bending radius permitted by the NEC for trade size 1 / 2 conduit is inches. a. 4 1 / 2 b. 7 1 / 4 c. 5 3 / 4 d. 8 1 / 4 e When sizing a feeder, the appliance loads in dwelling units can apply a demand factor of 75 percent of nameplate ratings for or more appliances fastened in place on the same feeder. a. two b. three c. four

4 d. five 26. These devices generally do not require special consideration of area or volume when mounted in a box or enclosure. a. tamper resistant receptacles. d. GFCI devices. b. range or dryer receptacles. e. fire alarm system components. c. dimmer switches. 27. What is utilization equipment? a. The utility panels, raceways and associated service boxes. b. The equipment used in conjunction of servicing commercial feeders. c. Equipment that utilizes electric energy for heating, lighting, or similar purposes. d. A type of surface, flush or free standing raceway designed to hold conductors. 28. The minimum bending radius permitted by the NEC for trade size 1 1 / 4 conduit is inches. a. 4 1 / 2 b. 7 1 / 4 c. 5 3 / 4 d. 8 1 / 4 e A disconnecting means shall be provided for all ungrounded conductors derived from a stationary battery system over. a. 200 amps. d. 50 amps. b. 50 volts. e. 48 volts. c. 30 volts. 30. The minimum bending radius permitted by the NEC for trade size 3 / 4 conduit is inches. a. 4 1 / 2 b. 7 1 / 4 c. 5 3 / 4 d. 8 1 / 4 e A single-family dwelling has a service entrance with a 200 ampere main circuit breaker. All service entrance conductors are copper with 75 C insulation and terminations. The ungrounded service entrance conductors for this dwelling are size 2/0 AWG. If the maximum unbalance load calculation for this dwelling is 110 amperes, the minimum size neutral conductor permitted for the service is: a. 4 AWG. b. 3 AWG. c. 2 AWG. d. 3/0 AWG. e. 4/0 AWG. 32. The following bends are made in a run of EMT or RMC between a 4-square box and a panel: one 10º box offset + one 45º 3-pt saddle + two 30º offsets + one 30º 4-pt saddle. Is this a violation of the NEC? a. No b. Yes 33. What NEC chapter covers all types of conduit wiring methods and materials? a. 8 b. 2 c. 3 d For the support of EMT, the maximum distance (without using exceptions) from a box to the first strap (support) is feet.. a. 12 b. 10 c. 2 d Where a rigid metal conduit enters a box that is designed to provide abrasion protection, is it required to have a bushing? a. Yes b. No

5 36. Part II of the definitions (Article 100) covers circuits of over volts. a. 120 b. 240 c. 480 d A circuit breaker is. a. the wiring that runs out to the utility b. a device designed to open and close a circuit by nonautomatic means c. the circuit conductors between the final overcurrent device and the outlets d. the overcurrent that supplies power 38. As noted in the introduction to NEC Article 90, are highlighted with gray shading within sections and with vertical ruling for large blocks of changed or new text and for new tables and changed or new figures. a. changes since the last code c. deleted articles b. special areas of attention d. enforcement by local jurisdictions 39. The 3 volt-ampere per square foot for dwelling unit general lighting includes all 15- and 20-ampere general-use receptacles. The floor area shall open porches, garages, or unused or unfinished spaces not adaptable for future use. a. include b. not include 40. According to Chapter 9 - Table Notes in the NEC, any conduit that is inches or shorter in length is considered to be a nipple. a. 18 b. 28 c. 24 d What word or words must be included in any Code article that is mandatory? a. may, may not b. shall, shall not c. would, would not d. can, cannot 42. A fixed, stationary, or portable self-contained electrically illuminated utilization equipment is a(n). a. luminaire b. outlet c. fixture d. electric sign 43. A feeder or service neutral load can be figured at of the load on the ungrounded conductors for ranges and ovens. a. 125 percent b. 80 percent c. 70 percent d. none of the above 44. The inside of enclosures and raceways installed below grade: a. shall meet the requirements of 310.8(C). b. require connectors and splices to be listed. c. are considered wet locations. d. all of the above. e. Are considered damp locations by the 2011 NEC. 45. What is the feeder demand for one 15kW range? a. 15kW c. 9.2kW b. 12kW d. none of these 46. Type NM cable shall not be installed: a. or fished in air voids in masonry block or tile walls. d. in conduit or tubing

6 b. above a suspended ceiling e. in wet or damp locations c. in multi-family dwellings 47. A copper feeder with 75 C insulation and terminations supplies two 460 volt, three-phase, design B electric motors, one rated 50 horsepower and the other rated 40 horsepower. The minimum size feeder conductor permitted for this load is: a. 4 AWG. b. 3 AWG. c. 2 AWG. d. 1 AWG. e. 1/0 AWG. 48. Where installing EMT, the maximum distance (without using exceptions) between the first support and a box is. a. 12" b. 10' c. 2' d. 3' e. 24" 49. Branch circuits are rated according to. a. the size of the wire used for the circuit c. neither a nor b b. the ampere rating of the overcurrent d. either a or b device 50. For electrical metallic tubing (EMT), what is the maximum number of degrees you can bend the tubing? a. 360 b. 270 c. 180 d A complete lighting unit consisting of a lamp together with the parts to distribute light is a(n). a. luminaire b. outlet c. fixture d. electric sign 52. For a run of electrical metallic tubing (EMT) between a panel and a box, what is the maximum number of degrees of bends you can put in this run? a. 180 b. 270 c. 90 d. 360 e. none of these

7 Spring Test 9 due 05/11/2013 Answer Section MULTIPLE CHOICE 1. ANS: C REF: 2. ANS: D REF: OBJ: 106 NEC Worksheet 3. ANS: D (C) 4. ANS: B Table ANS: A (2 10º) + (2 45º) + (2 30º) + (2 30º) + (60º) = 290º 2011 NEC: & REF: 2011 NEC: & ANS: C REF: 7. ANS: B REF: 8. ANS: E 2011 NEC: Ch 9-Table Notes REF: 2011 NEC: Ch 9-Table Notes 9. ANS: C look up the branch circuit selection current in the 60 C column Table (B)(16), , ANS: C NEC , Note 3 Column B for 3 appliances is 55%. 55% X 13kW = 7.15kW

8 11. ANS: C 2011 NEC: Table 2 - Ch 9 REF: 2011 NEC: Table 2 - Ch 9 OBJ: 106 NEC Worksheet 12. ANS: C 2011 NEC: Chapter 3 REF: 2011 NEC: Chapter ANS: A Article ANS: E , OESC ANS: B 2011 NEC: Ch 9-Table Notes REF: 2011 NEC: Ch 9-Table Notes OBJ: 106 NEC Worksheet 16. ANS: B REF: 17. ANS: A ANS: C Article ANS: B OESC 90 Amend Article 90 Introduction (1) Section 90.4 Enforcement. Amended as follows: (a) Amend 90.4 by inserting the following after the second paragraph: Requests for special permission shall be made in writing to the authority having jurisdiction. Special permission must be granted in writing by the authority having jurisdiction and shall be obtained prior to the start of the electrical installation. (A) Insert the following after Section 90.4: Section 90.4(A)Where the 2008 NEC requires electrical products to be "listed" or "labeled", the words "listed or "labeled" shall have the same meaning as "certified electrical product" under ORS ANS: D

9 REF: 21. ANS: C OAR (1)(b) 22. ANS: E 2011 NEC: REF: 2011 NEC: ANS: B (5)(d) 24. ANS: E 2011 NEC: Table 2 - Ch 9 REF: 2011 NEC: Table 2 - Ch ANS: C ANS: A Article ANS: C REF: 28. ANS: B 2011 NEC: Table 2 - Ch 9 REF: 2011 NEC: Table 2 - Ch ANS: C ANS: A 2011 NEC: Table 2 - Ch 9 REF: 2011 NEC: Table 2 - Ch ANS: C There is no special table for sizing the neutral conductor. Table (B)(16) 32. ANS: A (2 10º) + (2 45º) + (2 30º) + (2 30º) + (4 30º) = 350º 2011 NEC: &

10 REF: 2011 NEC: & OBJ: 106 NEC Worksheet 33. ANS: C 2011 NEC: Chapter 3 REF: 2011 NEC: Chapter 3 OBJ: 106 NEC Worksheet 34. ANS: D 2011 NEC: (A) REF: 2011 NEC: (A) 35. ANS: B 2011 NEC: REF: 2011 NEC: OBJ: 106 NEC Worksheet 36. ANS: D REF: 37. ANS: B REF: OBJ: 106 NEC Worksheet 38. ANS: A 2011 NEC: Article 90 preface REF: 2011 NEC: Article 90 preface OBJ: 106 NEC Worksheet 39. ANS: B ANS: C 2011 NEC: Ch 9-Table Notes REF: 2011 NEC: Ch 9-Table Notes 41. ANS: B 2011 NEC: 90.5(A) REF: 2011 NEC: 90.5(A) 42. ANS: D REF: 43. ANS: C NEC ANS: D

11 45. ANS: C NEC Note 1 15kW - 12kW = 3kW 3 X.05 =.15 Make this a multiplier by putting a 1 in front. Go to Table , Col C...one range is 8kW. Increase this by the multiplier, X 1.15 = 9.2kW 46. ANS: E (B)(4) 47. ANS: E 65 A 1.25 = 81 A 52 A 1.00 = _52 A 133 A , Table , Table (B)(16) 48. ANS: D 2011 NEC: (A) REF: 2011 NEC: (A) 49. ANS: B 2011 NEC: REF: 2011 NEC: NAT: Obj ABank 50. ANS: A 2011 NEC: REF: 2011 NEC: ANS: A REF: 52. ANS: D 2011 NEC: REF: 2011 NEC:

Spring Test 5 due 4/26/2013

Spring Test 5 due 4/26/2013 Spring Test 5 due 4/26/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Where fixed multioutlet assemblies are employed, each feet or fraction thereof

More information

Fall Test 21 due 12/11/2012

Fall Test 21 due 12/11/2012 Fall Test 21 due 12/11/2012 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Emergency system transfer equipment, including automatic transfer switches,

More information

Spring Test 17 due 06/14/2013

Spring Test 17 due 06/14/2013 Spring Test 17 due 06/14/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. The NEC defines cable as a cylindrical assembly composed of a conductor centered

More information

Spring Test 16 due 06/14/2013

Spring Test 16 due 06/14/2013 Spring Test 16 due 06/14/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. Figure 234.142 1. Refer to the information shown in Figure 234.142. Motor 1

More information

Spring Test 13 due 06/14/2013

Spring Test 13 due 06/14/2013 Spring Test 13 due 06/14/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. The power supply to the mobile home shall be a feeder assembly consisting

More information

NEC 2008 Code Changes Top 20 Revisions. By: Rafi Wartan, PE, LEED AP

NEC 2008 Code Changes Top 20 Revisions. By: Rafi Wartan, PE, LEED AP NEC 2008 Code Changes Top 20 Revisions By: Rafi Wartan, PE, LEED AP #1 Article 210.4 MULTIWIRE BRANCH CIRCUITS The rule on simultaneous disconnecting means requirements for multiwire branch circuits was

More information

Entry Level Assessment Blueprint Electrical Occupations

Entry Level Assessment Blueprint Electrical Occupations Entry Level Assessment Blueprint Electrical Occupations Test Code: 3029 / Version: 01 Specific Competencies and Skills Tested in this Assessment: Safety Apply shop safety rules and ergonomics Explain fire

More information

Meter Enclosure and Equipment Standards

Meter Enclosure and Equipment Standards Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable

More information

Electrical Components and Equipment for General Use Self Inspection Checklist

Electrical Components and Equipment for General Use Self Inspection Checklist Name of School: Optional Information Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Electrical Components and Equipment for General Use Self Inspection Checklist Guidelines:

More information

2014 AFCI code compliant safety. Understanding the 2014 NEC. for AFCI protection

2014 AFCI code compliant safety. Understanding the 2014 NEC. for AFCI protection 2014 AFCI code compliant safety Understanding the 2014 NEC for AFCI protection Understanding the code for code compliant safety An arc fault is an unintended arc created by current flowing through an unplanned

More information

Testing for safe and efficient branch circuits

Testing for safe and efficient branch circuits Testing for safe and efficient branch circuits Written by Chad Reynolds, Product Manager, IDEAL Test and Measurement Division Branch Circuit Testing Branch circuit wiring and testing practices are primarily

More information

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D. Electrical Integration of PV Systems Ridha Hamidi, Ph.D. 1 Many articles in the NEC are applicable to the electrical integration of a PV system, particularly Article 690. 2 The NEC defines the various

More information

Why is my AFCI tripping?

Why is my AFCI tripping? www.garyklinka.com Page 1 of 21 Instructions: Fee $25 1. Print these pages. 2. Use the included information located on pages 12-20 to answer the 61 questions below. 3. Circle the correct answers and transfer

More information

SECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 26 27 26 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Introduction to the Inspection Checklist for Rooftop Solar Photovoltaic (PV) Systems in Goshen, IN

Introduction to the Inspection Checklist for Rooftop Solar Photovoltaic (PV) Systems in Goshen, IN Introduction to the Inspection Checklist for Rooftop Solar Photovoltaic (PV) Systems in Goshen, IN This Inspection Checklist for Rooftop Photovoltaic (PV) Systems is based on the Model Inspection Checklist

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

Stalking the Elusive and Somewhat Strange PV System

Stalking the Elusive and Somewhat Strange PV System A series of articles on photovoltaic (PV) power systems and the National Electrical Code by John Wiles PERSPECTIVES ON PV Stalking the Elusive and Somewhat Strange PV System Photo 1. Framed PV modules

More information

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death. Installation/Operation Manual TABLE OF CONTENTS Page UNPACKING AND INSTALLATION Unpacking and Preliminary Inspection...2, 3 Model Number...9 LOCATION CONSIDERATIONS Environment, Equipment Performance,

More information

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...

More information

CATALOG NUMBER PROJECT W2 TRACK AND COMPONENTS

CATALOG NUMBER PROJECT W2 TRACK AND COMPONENTS CATALOG NUMBER TYPE PROJECT W2 TRACK AND COMPONENTS Description W2 120V or 277V Track system provides two separate 20 AMP circuits and two neutrals. Each circuit can be independently switched. Fully polarized

More information

Bulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010

Bulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010 Ontario Electrical Safety Code - Bulletins 50-1-0 Bulletin 50-1-0 Installation of Solar Photovoltaic Systems Section 50; Rules: 84-020, 84-024, 84-030; Tables 11 and 19 Issued July 2010 Scope (1) Introduction

More information

UNDERCARPET CABLING SYSTEM For Power and Communications

UNDERCARPET CABLING SYSTEM For Power and Communications UNDERCARPET CABLING SYSTEM For Power and Communications Linking Everything Together Power, Voice, and Data December 5, 2007 Undercarpet Cabling System Overview What is Undercarpet Cabling? Primary Applications

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 5 APPR:LWB:DBP:07-31-13

More information

Blueprint Drawings & Wiring Diagrams. for branch circuits

Blueprint Drawings & Wiring Diagrams. for branch circuits Blueprint Drawings & Wiring Diagrams for branch circuits Blueprint Symbols Wiring Diagram Symbols 2 Table of Contents Single Pole Switching p. 5-11 Three-way Switching p. 12-18 Four-way Switching p.19-25

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist TES A. Roads-Service, Lanes Common Items Trails and service roads provide adequate access to buildings for maintenance B. Testing Results-provided to the local government construction representative Data

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS - For use with CONTROLTrack System Only When installing or using this track system, basic safety precautions should always be

More information

Page 1 of 34

Page 1 of 34 www.garyklinka.com Page 1 of 34 Instructions: Fee $65 1. Print these pages. 2. Circle the correct answers and transfer them to the answer sheet. 3. Page down to the last page for the verification forms

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 6 APPR:MDW:JVG:06-08-18

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: Members of the NEC-Code Making Panel 3 FROM: Jean

More information

Emery County Senior Center Green River 06/07

Emery County Senior Center Green River 06/07 SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

The purpose of this document is to specify the power requirements for Core Health and Fitness LLC equipment.

The purpose of this document is to specify the power requirements for Core Health and Fitness LLC equipment. Power Requirements Applies to: All Machines The purpose of this document is to specify the power requirements for Core Health and Fitness LLC equipment. Latest Rev. Attention: Obtain the assistance of

More information

Satellite INSTALLATION GUIDE

Satellite INSTALLATION GUIDE N3 Satellite INSTALLATION GUIDE ! WARNING! Shock Hazard. May result in serious injury or death. Turn power OFF at circuit breaker or remove fuse. Damage to this product caused by wiring with power on voids

More information

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section. SECTION 16140 WIRING DEVICES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and Division 1 Specification Sections, apply to this Section. 1.02 SUMMARY A. This Section includes receptacles, connectors,

More information

NT-2300 Series Dual Circuit Track System & Accessories

NT-2300 Series Dual Circuit Track System & Accessories ILLUMINATING THE FUTURE...SINCE 1989 NT-2300 Series Dual Circuit Track System & Accessories Type Project Catalog No. Lamp/Wattage PRODUCT DESCRIPTION Low profile, extruded aluminum track with 20-Amp rated

More information

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL UNITED STATES Contents Safety Information... 2 Save These Important Safety Instructions... 2 Warnings...2 Cautions...3 General Information... 4 Mobile Connector

More information

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6 CFS Family TITLE PAGE Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6 Part Number Model Description A70-00-5006

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC 5-, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC 5-,

More information

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see

More information

SECTION WIRING DEVICES

SECTION WIRING DEVICES SECTION 16141 WIRING DEVICES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

R-LB R-LX Series Installation, Operation & Maintenance Manual

R-LB R-LX Series Installation, Operation & Maintenance Manual Installation, Operation & Maintenance Manual WARNINGS Safety First Hazardous Voltage & Shock Hazard Only qualified licensed electricians should install or service SPDs Hazardous voltages exist within SPDs

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

Page 1 of 149 First Revision No. 50-NFPA 79-2012 [ Global Input ] Delete the parenthetical terms used to describe IEC terms that follow terms used in NFPA 79 such as "protective bonding". Add information

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

SECTION ELECTRIC METERING

SECTION ELECTRIC METERING SECTION 26 27 13 ELECTRIC METERING SPEC WRITER NOTES: Use this section only for NCA projects Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter Install Guide Revision C (12/18) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Revision C (12/18) Turn off all power supplying equipment

More information

BuildingName The Description of the Project P DOCUMENTS

BuildingName The Description of the Project P DOCUMENTS P00000000 0000 DOCUMENTS ARCHITECTURE, ENGINEERING AND CONSTRUCTION ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual APC 2X Series Hardwire Products PMP2X-A PMF2X-A PMG2X-A PMH2X-A APC hardwired products are designed to provide specification-grade performance at the service entrance,

More information

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: Members of the NEC-Code Making Panel 13 FROM:

More information

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Individually Mounted Switches and Circuit Breakers Used for the following: a. Service

More information

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide *619751* P/N 619751 - Rev B IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS

More information

1510 MOTOR CONTROLLERS

1510 MOTOR CONTROLLERS SECTION 262913- MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of contract, including general and supplementary conditions and Division 1 specification section,

More information

Instruction Manual: IM E

Instruction Manual: IM E Innovative Technology TVSS Products The I.T. Equalizer Installation Instruction Manual: IM01005011E Rev. 2 May 2009 Contents Page 1 Introduction... 1 1.1 Scope... 1 1.2 I.T. Equalizer Catalog Numbering

More information

Microinverters And The Solar Industry

Microinverters And The Solar Industry Microinverters And The Solar Industry Peter Lum Senior Learning And Development Professional Assistant Professor Skyline College Solar Continues Its Growth 2 Significant Growth Of Microinverters in Solar

More information

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Date: Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of stations meets DD 9, applicable

More information

More Questions from Inspectors Numerous PV Systems Pose Issues

More Questions from Inspectors Numerous PV Systems Pose Issues Perspectives on PV More Questions from Inspectors Numerous PV Systems Pose Issues by John Wiles 76 IAEI NEWS March. April 2012 www.iaei.org Photovoltaic (PV) systems prices continue to drop and inspectors

More information

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits Course Details Date: January 28 January 31, 2019 Time: 8:00 A.M. - 4:30 P.M. Capacity: 12 attendees Provider: National Technology

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

SureTest Model ST 1D Instructions

SureTest Model ST 1D Instructions #61-152 #61-153 SureTest Model ST 1D Instructions Introduction The SureTest family of circuit analyzers identify problems common to electrical circuits quickly, easily and accurately. They have a patented

More information

Duplex Convenience Receptacles

Duplex Convenience Receptacles PDHonline Course E292 (2 PDH) Duplex Convenience Receptacles Instructor: David A. Snyder, PE 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088 www.pdhonline.org

More information

powerbrite led Lighting Systems & Modules

powerbrite led Lighting Systems & Modules powerbrite led Lighting Systems & Modules Instructions for Model PowerBrite LED #1643, 1644, 1645, 1646, 1647, 1648 Important Safety Instructions... Page 2 Installation Instructions... Page 4 Warranty...

More information

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

It is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template.

It is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template. 6. ENGINEERING SYSTEMS REQUIREMENTS G40 SITE ELECTRICAL UTILITIES SYSTEMS REQUIREMENTS SITE ELECTRICAL UTILITIES TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT

More information

FDS / FDS-R / FDS-PS

FDS / FDS-R / FDS-PS FDS / FDS-R / FDS-PS USER MANUAL For use with 120V 60Hz input. Output is 120V 60Hz at 5amps 600W MAX. switched. ETL LISTED Conforms to UL STD 1241 3091594 79-15167-00 REV. A www.fiberstars.com Page 1 of

More information

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing Understanding SCCR What is SCCR? When it comes to industrial machinery, it s critical to ensure that electrical panels are designed and built with the proper SCCR to maintain the system, eliminate downtime

More information

Rapid Shutdown Requirements for NEC 2017

Rapid Shutdown Requirements for NEC 2017 2017 AEESOLAR DEALER CONF. Rapid Shutdown Requirements for NEC 2017 Presented by: Bill Brooks, CMP 4 2017 NEC Statistics for Article 690 Whole article was reduced from 11,000 words to about 8,000 words.

More information

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering

More information

Residential 1-Line Multifamily Instructions. User s Manual APPROVED. Copyright 2016 Durand & Associates. Page 1

Residential 1-Line Multifamily Instructions. User s Manual APPROVED. Copyright 2016 Durand & Associates. Page 1 Residential 1-Line 2017 Multifamily Instructions APPROVED User s Manual Copyright 2016 Durand & Associates Page 1 Using Residential 1-Line 2017 with Excel Excel 1997-2003 This product was designed with

More information

TransEnd Surge Suppression Filter Systems

TransEnd Surge Suppression Filter Systems Installation, Operation and Maintenance Manual P 750-0064-REV. 44 TransEnd TransEnd Surge Suppression Filter Systems TransEnd 100 TransEnd 80 TransEnd 50 TransEnd 25 JOSLY ISTALLATIO, OPERATIO AD MAITEACE

More information

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH) Surge-Trap STZ-R series Surge Protective Device (SPD) Danger Hazard of Electrical Shock, Explosion or Arc Flash Only qualified licensed electricians should install or service SPDs Verify that all power

More information

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe

More information

SECTION WIRING DEVICES

SECTION WIRING DEVICES SECTION 26 27 26 WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Receptacles, receptacles with integral GFCI, and associated device plates. 2. Twist-locking receptacles.

More information

UL 508 A standard-compliant design of industrial control panel

UL 508 A standard-compliant design of industrial control panel UL 508 A standard-compliant design of industrial control panel Axel Jöhnke System Architecture Expert 14-15 SEPTEMBER 2011, MUNICH Agenda www.infoplc.net Origin and Comprehension Organizations Certificates

More information

NECA 130. Standard for Installing and Maintaining Wiring Devices. Industry Review Draft (Date TBD)

NECA 130. Standard for Installing and Maintaining Wiring Devices. Industry Review Draft (Date TBD) NECA 130 Standard for Installing and Maintaining Wiring Devices Industry Review Draft (Date TBD) National Electrical Installation Standards, NEIS, and the NEIS logo are trademarks of the National Electrical

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase

More information

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC. [Refer to Engineering Notes at End of Spec] Section [16XXX] [264XXX] - SURGE PROTECTIVE DEVICES (SPDs) PART 1 - GENERAL 1.1 SCOPE A. This section includes Surge Protective Devices (SPDs) for low-voltage

More information

Section 1. 1 How to Study This Course & Achieve Your Personal Goals Orientation (J200.I) 1

Section 1. 1 How to Study This Course & Achieve Your Personal Goals Orientation (J200.I) 1 All materials are copyrighted by the National Joint Apprenticeship and Training Committee. No material may be reproduced without the express written permission of the NJATC. Section 1 1 How to Study This

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: Members of the NEC-Code Making Panel 13 FROM:

More information

Document C0. Use for:

Document C0. Use for: Date: July 27, 2015 Document C0 Use for: Connection of Electric Generation that will operate with an Open Transition (Category 1) between the Ameren System and the Generator or operate with a Synchronized

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225 A, 8 to 42

More information

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO Cabling Standards Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO 1. Purpose CABLING STANDARDS This technical note

More information

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches Series 300 Power Transfer Switches Maximum Reliability & Excellent Value With a Series 300 Transfer Switch, you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually

More information

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation SECTION 26 24 16 PANELBOARDS PART 1 -GENERAL 1.1 SUMMARY A. Section includes distribution and branch circuit panelboards, electronic grade branch circuit panelboards, [and load centers]. 1.2 REFERENCES

More information

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: +31

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: Members of the NEC-Code Making Panel 11 FROM:

More information

MEMORANDUM SUBJECT: APPROVED POWER STRIPS AND SURGE PROTECTORS

MEMORANDUM SUBJECT: APPROVED POWER STRIPS AND SURGE PROTECTORS MEMORANDUM DATE: December 15, 2013 TO: Campus Community FROM: Tim Ridley, CSP, ARM-P Director, Safety and Risk Management SUBJECT: APPROVED POWER STRIPS AND SURGE PROTECTORS Safety & Risk Management inspections

More information

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS SECTION 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Nameplates. 2. Labels. 3. Wire markers. 4. Conduit markers. 5. Underground Warning Tape. 6. Lockout

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs) ga GE Digital Energy Power Quality INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs) 2020005003 (12/09) Page 1 of 18

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.

More information

AIR COOLED MODULAR RECTIFIER

AIR COOLED MODULAR RECTIFIER CONTROLLED POWER COMPANY SPECIFICATIONS AIR COOLED MODULAR RECTIFIER Spc1800a1 5JAN1999 SPECIFICATION S-1800-A MODULAR (REMOVABLE AND NON-REMOVABLE MODULES) AIR COOLED RECTIFIER Standard output power range:

More information

AT&T Switched Ethernet Service SM

AT&T Switched Ethernet Service SM Site Preparation Guide AT&T Switched Ethernet Service SM December 2016 2016 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo, Mobilizing Your World and DIRECTV are registered trademarks

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

Two Circuit Track Power System IS24 / IS26 / IS28

Two Circuit Track Power System IS24 / IS26 / IS28 Two Circuit Track Power System IS24 / IS26 / IS28 DESCRIPTION Two circuit / single neutral track is an affordable and durable solution that features easy installation. Track system is available in 4, 6,

More information