SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Size: px
Start display at page:

Download "SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005"

Transcription

1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 TA TECHNOLOGY (SHANGHAI) CO., LTD. Building 3, No. 145 Jintang Rd. Tangzhen Industry Park Pudong, Shanghai, People s Republic of China Mr. Zhihui (Henry) Liu (liuzhihui@ta-shanghai.com) ELECTRICAL Valid to: November 30, 2019 Certificate Number: In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following Telecommunications, Electromagnetic Compatibility (EMC), and Radio Tests: Test Technology: Unintentional Radiators (up to 40 GHz) Radiated & Conducted CFR 47, FCC Part 15 Subpart B, (using ANSI C63.4:2014); CFR 47, FCC Part 18 (Using MP-5:1986); CISPR 22; EN 55022; CISPR 32; EN 55032; ICES-003; GB 9254 Harmonic Current Emissions GB ; IEC ; EN Voltage Fluctuations and Flicker GB ; IEC ; EN Immunity Electrostatic Discharge (ESD) GB/T ; IEC ; EN Radiated Immunity GB/T ; IEC ; EN Electrical Fast Transient/Burst (EFT) GB/T ; IEC ; EN Surge GB/T ; IEC ; EN Conducted Immunity GB/T ; IEC ; EN Power Frequency Magnetic Field GB/T ; IEC ; EN Voltage Dips, Short Interruptions, and Voltage Variations GB/T ; IEC ; EN (A2LA Certificate No ) 12/19/2017 Page 1 of 4

2 Test Technology: Intentional Radiators (up to 40 GHz) Unlicensed Radio - FCC U-NII with DFS CFR 47, FCC Part 15, Subpart C (using ANSI C63.10:2013) CFR 47, FCC Part 15, Subpart E (using ANSI C63.10:2013) and FCC KDB Publication C02 UNII DFS Compliance Procedures New Rules v01 (April 8, 2016) Licensed Radio - FCC CFR 47, FCC Parts 22, 24, 25, 27, 90, 95, 97, 101; (using ANSI/TIA-603-D and KDB Publication ) Canada - Radio RSS-Gen; RSS-119; RSS-132; RSS-133; RSS-210; RSS-216; RSS-247 European Union (EU) ETSI EN , -2; ETSI EN , -2, -13; ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN , -2; ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN Australia RF Performance Measurements Over-the-Air Performance (OTA) RF Exposure (up to 6 GHz) Specific Absorption Rate (SAR) AS/CA SO42.1; AS/ACIF S042.3; AS/CA SO42.4; AS/NZS 4268 CTIA Test Plan for Wireless Device Over-the-Air Performance; 3GPP TS ; 3GPP TS25.914; 3GPP TS ; 3GPP TS25.144; 3GPP TS ; 3GPP TR ; CTIA and Wi-Fi Alliance Test Plan for RF Performance Evaluation of Wi-Fi Mobile Converged Devices; ANSI/IEEE Std 149 ANSI/IEEE C95.1; IEEE C95.1a; IEEE 1528:2013; IEEE 1528a; ICNIRP Guidelines; EN 50360; EN 50566; EN 50364; EN 50383; EN 50385; IEC , -2; EN , -2; BIS IS ; IEC 62232; IEC 62311; EN 62311; IEC 62369; EN 62369; IEC 62479; EN 62479; RSS-102 (A2LA Certificate No ) 12/19/2017 Page 2 of 4

3 Test Technology: Hearing Aid Compatibility (HAC) FCC Part using ANSI C Radio Communications (Wireless) (Limited to testing of Transceiver, Transmitter and Receiver, as applicable) WCDMA/GSM ETSI TS ; 3GPP TS ; ETSI TS ; 3GPP TS ; ETSI TS ; 3GPP TS LTE ETSI TS ; 3GPP TS ; ETSI TS ; 3GPP TS ; ETSI TS ; 3GPP TS Bluetooth SIG Bluetooth RF Conformance Tests Bluetooth Profile Conformance Tests TS, TSS & TP as outlined in the Bluetooth Qualification Program Test Case Reference List (TCRL) Electrical Product Safety Electrical Product Safety (IT) GB ; YD/T 965; EN ; AS/NZS ; IEC 60065; EN 60065; AS/NZS Generic / Product Family / Product Specific Standards GB/T ; IEC ; EN ; GB/T ; IEC ; EN ; GB/T ; IEC ; EN ; GB/T ; IEC ; EN ; ETSI EN , -3, -5, -6, -9, -17, -19, -27, -28, -29, -31, -33, -34, -35, -50, -52, -53; CISPR 24; EN 55024; EN61547; AS/NZS ; AS/NZS ; GB/T 17618; GB/T ; GB/T ; YD/T 968; YD ; YD ; YD ; YD ; YD/T ; YD/T ; YD/T ; YD/T On the following products or types of products: Radio Equipment and Telecommunications Terminal Equipment (R&TTE), Information Technology Equipment (ITE), Industrial, scientific and medical(ism) radio-frequency equipment, Household appliances, electric tools and similar apparatus, Audio and Video Equipment, Lighting equipment. (A2LA Certificate No ) 12/19/2017 Page 3 of 4

4 Testing Activities Performed in Support of FCC Declaration of Conformity and Certification in Accordance with 47 Code of Federal Regulations and FCC KDB , Appendix A, Table A.1 1 : Rule Subpart/Technology Test Method Maximum Frequency Unintentional Radiators Part 15B ANSI C63.4:2014 Industrial, Scientific, and Medical Equipment Part 18 FCC MP-5 (February 1986) Intentional Radiators Part 15C ANSI C63.10:2013 U-NIII without DFS Intentional Radiators Part 15E ANSI C63.10:2013 U-NII with DFS Intentional Radiators Part 15E Commercial Mobile Services (FCC Licensed Radio Service Equipment) Parts 22 (cellular), 24, 25 (non-microwave), and 27 General Mobile Radio Services (FCC Licensed Radio Service Equipment) Parts 22 (non-cellular), 90 (non-microwave), 95, 97, and 101 (non-microwave) FCC KDB Publication D02 (v01) ANSI/TIA-603-D ANSI/TIA-603-D RF Exposure Devices Subject to SAR Requirements IEEE Std 1528: MHz Hearing Aid Compatibility Part 20 (HAC for Commercial Mobile Services) ANSI C63.19: MHz 1 Accreditation does not imply acceptance to the FCC equipment authorization program. Please see the FCC website ( for a listing of FCC approved laboratories. (A2LA Certificate No ) 12/19/2017 Page 4 of 4

5 Accredited Laboratory A2LA has accredited TA TECHNOLOGY (SHANGHAI) CO., LTD. Shanghai, People s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 19 th day of December President and CEO For the Accreditation Council Certificate Number Valid to November 30, 2019 For the tests to which this accreditation applies, please refer to the laboratory s Electrical Scope of Accreditation.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MICROSOFT EMC LABORATORY 1 17760 NE 67 th Court Redmond, WA 98052 Sajay Jose Email: sajose@microsoft.com Phone: 425 421 9799 ELECTRICAL (EMC) Valid to: August

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 GLOBAL COMPLIANCE AND TESTING CENTER OF HUAWEI TECHNOLOGIES CO., LTD. (RELIABILITY LABORATORY OF HUAWEI TECHNOLOGIES CO., LTD.). 1 Administration Building,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 A TEST LAB TECHNO CORP. 101-104, 1F, A Building, Taoyuan Street Safflower Ridge Industrial Area, Nanshan District Shenzhen, 518055, People s Republic of China

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SHENZHEN ACADEMY OF METROLOGY AND QUALITY INSPECTION 1 NETC Building, No. 4 Tongfa Road Xili, Nanshan Shenzhen, Guangdong, 518055, People s Republic of China

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CETECOM INC. 411 Dixon Landing Road Milpitas, CA Franz Engert Phone: ELECTRICAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CETECOM INC. 411 Dixon Landing Road Milpitas, CA Franz Engert Phone: ELECTRICAL SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CETECOM INC. 411 Dixon Landing Road Milpitas, CA 95035 Franz Engert Phone: 408 586 6205 ELECTRICAL Valid to: December 31, 2019 Certificate Number: 2135.01 In

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SHENZHEN ACADEMY OF METROLOGY AND QUALITY INSPECTION 1 NETC Building, No. 4 Tongfa Road Xili, Nanshan District Shenzhen, Guangdong, 518055, People s Republic

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. LAIRD TECHNOLOGIES, INC. W66 N220 Commerce Court Cedarburg, WI Adam Alger Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. LAIRD TECHNOLOGIES, INC. W66 N220 Commerce Court Cedarburg, WI Adam Alger Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 LAIRD TECHNOLOGIES, INC. W66 N220 Commerce Court Cedarburg, WI 53012 Adam Alger Phone: 262 375 4400 ELECTRICAL (EMC) Valid to: January 31, 2019 Certificate

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY CO. LTD. Fl. 3, Building A, Fei Yang Science Park No. 8 Long Chang Road, Block 67 BaoAn District, Guangdong Province,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 BAY AREA COMPLIANCE LABORATORIES CORP. No. 69 Pulongcun Puxinhu Industrial Zone, Tangxia Town Dongguan, Guangdong 523719 People s Republic of China Mr. David

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 A TEST LAB TECHNO CORP. No.140-1, Changan Street Bade District Taoyuan City, Taiwan (R.O.C.) Kevin Tsai email: kevin@atl-lab.com.tw Phone: 886-3-2710188 Ext.

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 QUALITECH EMC & Product Safety Laboratory 30 Hasivim Street Petah-Tikva, 4959388, ISRAEL Teodor Weisz Phone: +972 3 926 6218 Email: Tedy.Weisz@ecitele.com Rami

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CETECOM INC. 411 Dixon Landing Road Milpitas, CA Franz Engert Phone: ELECTRICAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CETECOM INC. 411 Dixon Landing Road Milpitas, CA Franz Engert Phone: ELECTRICAL SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CETECOM INC. 411 Dixon Landing Road Milpitas, CA 95035 Franz Engert Phone: 408 586 6205 ELECTRICAL Valid to: May 31, 2018 Certificate Number: 2135.01 In recognition

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 JIANGSU YANGTZE TESTING, CERTIFCATION AND INSPECTION CORPORATION No.6-3, XingZhi Road, XingZhi Technology Park XinGang Economic Development Zone NanJing City,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 BAY AREA COMPLIANCE LABORATORIES CORP. 6/F, the 3rd Phase of WanLi Industrial Building Shihua Road, Futian Free Trade Zone Shenzhen, Guangdong 518038 People

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INTERTEK TESTING SERVICES NA 731 Enterprise Drive Lexington, KY 40510 Mr. James Sudduth 859 226 1000 james.sudduth@intertek.com ELECTRICAL Valid to: April 30,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SIEMIC (NANJING-CHINA) LABORATORIES 新美科 ( 南京 ) 信息技术有限公司 No. 2-1 Longcang Avenue Yuhua Economic Development Zone Yuhua District, Nanjing, 210039, People s Republic

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Ke Mei Ou Lab Co., Ltd. Room 2013-2016, 20

More information

Federal Communication Commission (FCC) Office of Engineering and Technology (OET) Program Accreditation Procedure

Federal Communication Commission (FCC) Office of Engineering and Technology (OET) Program Accreditation Procedure PJLA offers third-party accreditation services to Conformity Assessment Bodies (i.e. Testing and/or Calibration Laboratories, Reference Material Producers, Field Sampling and Measurement Organizations

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SIEMIC, INC. dba SIEMIC LABORATORIES 775 Montague Expressway Milpitas, CA 95035 Mr. Leslie Bai Phone: 408 526 1188 Email: leslie.bai@siemic.com www.siemic.com

More information

COMPANY PROFILE. vb_r6.1

COMPANY PROFILE. vb_r6.1 COMPANY PROFILE 1 El. products - placing on the market electronical product Compliance with international regulations Compliance with independent program requirements ETSI (R&TTE) FCC IC ARIB... & Global

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SIEMIC LABORATORIES 1 2206 Ringwood Ave. San Jose, CA 95131 Mr. Leslie Bai Phone: 408 526 1188 Email: leslie.bai@siemic.com Mr. Snell Leong Phone: 408 526 1188

More information

ANSI-ASQ National Accreditation Board/ACLASS

ANSI-ASQ National Accreditation Board/ACLASS ANSI-ASQ National Accreditation Board/ACLASS Washington Laboratories, Ltd. 1 7560 Lindbergh Drive Gaithersburg, Maryland 20879 John Repella Phone: 301-216-1500 TESTING Valid to: June 30, 2014 Certificate

More information

FCC Certification Process Overview (Revised February 15, 2017)

FCC Certification Process Overview (Revised February 15, 2017) FCC Certification Process Overview (Revised February 15, 2017) INTRODUCTION On November 22, 2016, the Federal Communications Commission has adopted rules to facilitate the continued rapid introduction

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 DEKRA TESTING AND CERTIFICATION, S.A.U. Parque Tecnologico de Andalucia C/ Severo Ochoa 2 29590-Campanillas, Málaga, SPAIN Jose Maria Fernandez Phone: +34 952619100

More information

COMMON REGULATORY OBJECTIVES FOR GSM EQUIPMENT PART 2 SPECIFIC ASPECTS OF GSM EQUIPMENT

COMMON REGULATORY OBJECTIVES FOR GSM EQUIPMENT PART 2 SPECIFIC ASPECTS OF GSM EQUIPMENT COMMON REGULATORY OBJECTIVES FOR GSM EQUIPMENT PART 2 SPECIFIC ASPECTS OF GSM EQUIPMENT 1. SCOPE This Common Regulatory Objective, CRO, is applicable to GSM equipment, as defined in Clause 2. A CRO is

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SGS NORTH AMERICA, INC. 15150 Avenue of Science, Suite 300 1 San Diego, CA 92128 Nathan Gieselman Phone: 858 592 7100 ELECTRICAL Valid To: July 31, 2018 Certificate

More information

Volume I, Appendix B References Table of Contents

Volume I, Appendix B References Table of Contents Volume I, Appendix B References Table of Contents B Appendix - References... B-1 B.1 Documents Incorporated in the Guidelines... B-1 B.2 Other Documents Used in Developing the Guidelines... B-3 B.3 Additional

More information

GUIDELINES ON FEATURES AND TECHNICAL SPECIFICATIONS FOR MOBILE CELLULAR DEVICES IMPORTED INTO AND DISTRIBUTED IN KENYA

GUIDELINES ON FEATURES AND TECHNICAL SPECIFICATIONS FOR MOBILE CELLULAR DEVICES IMPORTED INTO AND DISTRIBUTED IN KENYA GUIDELINES ON FEATURES AND TECHNICAL SPECIFICATIONS FOR MOBILE CELLULAR DEVICES IMPORTED INTO AND DISTRIBUTED IN KENYA June 2018 Table of Contents 1. Scope... 3 2. References... 4 3. Abbreviations and

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MET LABORATORIES, INC 1 3162 Belick Street Santa Clara, CA 95054 Frank Casbolt Phone: 410 949 1867 Frank.Casbolt@metlabs.com http://www.metlabs.com ELECTRICAL

More information

Volume I Appendix B. Table of Contents

Volume I Appendix B. Table of Contents Volume I, Appendix B Table of Contents B Appendix -...B-1 B.1 Documents Incorporated in the Standards...B-1 B.2 Standards Development Documents...B-3 B.3 Guidance Documents...B-4 i Volume I Appendix B

More information

Test Right. Design Right.

Test Right. Design Right. Test Right. Design Right. We are true professionals in RF OTA CTIA and 3GPP OTA Test Specifications Verkotan employees have been the key contributors into the CTIA and 3GPP Test Specifications since kick

More information

Reg Model : SKR001 Regulatory Assurance Certification

Reg Model : SKR001 Regulatory Assurance Certification Seagate Korea Design Center, Korea Reg Model : SKR001 Regulatory Assurance Certification DO NOT DUPLICATE CONTROLLED COPY This document has been issued electronically. Only the original recipient of the

More information

Coda cx1 EMI/EMC Test Procedure

Coda cx1 EMI/EMC Test Procedure Coda cx1 EMI/EMC Test Procedure CDL 1-TP07-0400:0209 MIT Ref. 85-01050.03 Revision 1.0 28 th March 2002 CDL 1-TP07-0400:0209 Contents 1 Introduction... 1 1.1 Activity Description... 1 2 Requirements...

More information

NIST Designation of CABs: Upcoming Changes for the US and EU Review for Japan

NIST Designation of CABs: Upcoming Changes for the US and EU Review for Japan NIST Designation of CABs: Upcoming Changes for the US and EU Review for Japan Japan MRA Workshop March 2, 2016 Presented by Ramona Saar Program Manager, NIST Version updated 2/26/2016 Topics Introduction:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INTERTEK TESTING SERVICES NA INC. 3933 U.S. Route 11 Cortland, NY 13045 Terence O Beirne Phone: 607 758 6316 www.intertek.com ELECTRICAL Valid To: March 31,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 BAY AREA COMPLIANCE LABORATORIES CORP. 1274 Anvilwood Avenue Sunnyvale, CA 94089 Ms. Lisa Tang Phone: 408 732 9162 ELECTRICAL Valid To: September 30, 2020 Certificate

More information

Features. Applications and Benefits TRC ELECTRONICS, INC

Features. Applications and Benefits TRC ELECTRONICS, INC Features Gelo LED power supplies are designed specifically for use in LED lighting, particularly well-suited for refrigeration, retail display and sign applications. The industry standard footprint and

More information

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24 Features Gelo LED power supplies are designed specifically for use in LED lighting, particularly well-suited for refrigeration, retail display and sign applications. The industry standard footprint and

More information

Gelo LED Driver 100W, Single output RGLD100-24

Gelo LED Driver 100W, Single output RGLD100-24 Features Gelo LED power supplies are designed specifically for use in refrigeration, retail display and sign applications. The industry standard footprint and very low profile design provide great benefits

More information

FCC Rules & Procedures. Roy Uggerud, Nemko Norway 25th January 2018

FCC Rules & Procedures. Roy Uggerud, Nemko Norway 25th January 2018 FCC Rules & Procedures Roy Uggerud, Nemko Norway 25th January 2018 Certification requirement Nearly every country requires certification before import and sale of the product 2 25.01.2018 FCC RULES & PROCEDURES

More information

Declarations of Conformity and Regulatory Information

Declarations of Conformity and Regulatory Information APPENDIXB Declarations of Conformity and Regulatory Information This appendix provides declarations of conformity and regulatory information for the Cisco Aironet 1130AG Series Access Points and the Cisco

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. TUV RHEINLAND OF NORTH AMERICA, INC Quarry Lane, Suite A Pleasanton, CA 94566

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. TUV RHEINLAND OF NORTH AMERICA, INC Quarry Lane, Suite A Pleasanton, CA 94566 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 TUV RHEINLAND OF NORTH AMERICA, INC. 1 1279 Quarry Lane, Suite A Pleasanton, CA 94566 Mr. Bruce Fagley Phone: 203 426 0888 x119 Email: bfagley@us.tuv.com www.tuv.com

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ECI TELECOM S LQLAB 30 Hasivim Street Petah-Tikva 4959338, ISRAEL Moshe Perel Phone: 972 52-4008642 Email: Moshe.Perel@ecitele.com ELECTRICAL Valid to: June

More information

HEC-100RTN-48QSCA Rev A1.0

HEC-100RTN-48QSCA Rev A1.0 HEC100RTN48QSCA Rev A1.0 A. Features High Efficiency (Up to 90%). Active Power Factor Correction (Typical 0.96). Isolation Class I (With FG) AllRound Protection: OVP/SCP/OTP/OPP. Fully isolated Metal case

More information

Cisco High-Density Packet Voice Digital Signal Processor Module for Cisco IP Communications Solution

Cisco High-Density Packet Voice Digital Signal Processor Module for Cisco IP Communications Solution Cisco High-Density Packet Voice Digital Signal Processor Module for Cisco IP Communications Solution Product Overview The Cisco High-Density Packet Voice Digital Signal Processor (DSP) Module (PVDM2) enables

More information

CompuScope 1602 product introduction

CompuScope 1602 product introduction CompuScope 1602 product introduction CompuScope 1602 is 16 bit dual channel, 2.5 MS/s waveform digitizer card for the PCI Bus. Recognizing that until very recently, almost all multi-megahertz data acquisition

More information

Constant Voltage Mode

Constant Voltage Mode FEATURES: AC Input 1~277VAC Built-in Active PFC Function Protection: SCP / OVP / OTP Flicker Free High Operating Ambient Temp.: -3 ~+6 Surge protection: L-N 4KV, L-FG/N-FG 8KV Safety: UL 875 / PSE EMI:

More information

CompuScope product introduction

CompuScope product introduction CompuScope 12100 product introduction CompuScope 12100 is a 12 bit, waveform digitizer card for the PCI Bus, capable of 100 MS/s sampling on one channel and 50 MS/s sampling on two simultaneous channels.

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MET LABORATORIES, INC 914 West Patapsco Avenue Baltimore, MD 21230 Frank Casbolt Phone 410 949 1867 Frank.Casbolt@metlabs.com http://www.metlabs.com ELECTRICAL

More information

FCC Statement Declaration of Conformity

FCC Statement Declaration of Conformity FCC Statement Declaration of Conformity Sony Ericsson U20i UMTS HSPA band 1 8 GSM GPRS/EDGE 850/900/1800/1900 Important Information United States & Canada THIS PHONE MODEL HAS BEEN CERTIFIED IN COMPLIANCE

More information

EN 62311:2008 ASSESSMENT REPORT. Shanghai Bwave Technology Co.,Ltd.

EN 62311:2008 ASSESSMENT REPORT. Shanghai Bwave Technology Co.,Ltd. EN 62311:2008 ASSESSMENT REPORT For Shanghai Bwave Technology Co.,Ltd. 6F, Building 12, 399 Keyuan Road, Zhangjiang Hi-Tech Park, Shanghai, China Model: BW8800 Report Type: Amended Report Product Type:

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61326 First edition 2002-02 Electrical equipment for measurement, control and laboratory use EMC requirements This English-language version is derived from the original bilingual

More information

Regulatory Update Brazil

Regulatory Update Brazil Product Compliance Specialists Ltd Tel: +44 1844 273 277 The Malthouse, Malthouse Square, Fax: +44 1844 273 278 Princes Risborough www.productcompliancespecialists.com Bucks, HP27 9AZ info@productcompliancespecialists.com

More information

High-Density Packet Voice Video Digital Signal Processor Module for Cisco Unified Communications

High-Density Packet Voice Video Digital Signal Processor Module for Cisco Unified Communications High-Density Packet Voice Video Digital Signal Processor Module for Cisco Unified Communications Product Overview The Cisco High-Density Packet Voice Digital Signal Processor Module (PVDM3) enables Cisco

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PJF Rockford Park Drive Rockford, MI Bernard Warchuck Phone: MECHANICAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PJF Rockford Park Drive Rockford, MI Bernard Warchuck Phone: MECHANICAL SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 PJF 6 301 Rockford Park Drive Rockford, MI 49341 Bernard Warchuck Phone: 616 866 8296 MECHANICAL Valid To: SEE FOOTNOTE 6 Certificate Number: 1856.01 In recognition

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PJF Rockford Park Drive Rockford, MI Bernard Warchuck Phone: MECHANICAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PJF Rockford Park Drive Rockford, MI Bernard Warchuck Phone: MECHANICAL SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 PJF 6 301 Rockford Park Drive Rockford, MI 49341 Bernard Warchuck Phone: 616 866 8296 MECHANICAL Valid To: SEE FOOTNOTE 6 Certificate Number: 1856.01 In recognition

More information

Read Me First for the HP ProCurve Wireless Products - software ver

Read Me First for the HP ProCurve Wireless Products - software ver Read Me First for the Wireless Products - software ver. 2.1.0 This Read Me First provides information for the following products: Wireless Access Point 520wl (J8133A) 802.11a AP Kit 160wl - N America +

More information

Cisco cbr-8 Converged Cable Access Router Supervisor 250G

Cisco cbr-8 Converged Cable Access Router Supervisor 250G Data Sheet Cisco cbr-8 Converged Cable Access Router Supervisor 250G Product overview The Cisco cbr-8 Converged Cable Access Router Supervisor 250G performs the data forwarding and routing processing functions

More information

Information on labelling and record-keeping Introduction devices

Information on labelling and record-keeping Introduction devices Information on labelling and record-keeping Electromagnetic compatibility requirements for suppliers of electrical and electronic devices, vehicles and devices with internal combustion engines in Australia

More information

Procedure for the Recognition of Foreign Testing Laboratories

Procedure for the Recognition of Foreign Testing Laboratories Issue 6 Amendment May 2018 Spectrum Management and Telecommunications Procedures for Conformity Assessment Bodies Procedure for the Recognition of Foreign Testing Laboratories Amendment: The definition

More information

Federal Communications Commission Office of Engineering and Technology Laboratory Division

Federal Communications Commission Office of Engineering and Technology Laboratory Division Federal Communications Commission Office of Engineering and Technology Laboratory Division Guidelines for Labelling and User Information for Devices Subject to Part 15 and Part 18 1. General This document

More information

National Standard of The People s Republic of China

National Standard of The People s Republic of China Translated English of Chinese Standard: GB/T17626.5-2008 Translated by: www.chinesestandard.net Wayne Zheng et al. Email: Sales@ChineseStandard.net ICS 33.100 L 06 GB National Standard of The People s

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Palindrome Technologies 100 Village Ct. Hazlet,

More information

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5 Table of Contents 1 SCOPE...5 2 ELECTRICAL SPECIFICATION...5 2.1 INPUT REQUIREMENT... 5 2.1.1 Input voltage range... 5 2.1.2 Input frequency range... 5 2.1.3 AC inrush current... 5 2.1.4 Input current...

More information

BLACKBERRY RADAR H2 ITC100 1 ITC100 2 February 2019

BLACKBERRY RADAR H2 ITC100 1 ITC100 2 February 2019 BLACKBERRY RADAR H2 ITC100 1 ITC100 2 February 2019 1 Safety information Before you start using the BlackBerry Radar H2 device (herein after referred to as device), review the safety and regulatory information

More information

Smart Meters Programme Schedule 2.3. (Standards) (CSP South version)

Smart Meters Programme Schedule 2.3. (Standards) (CSP South version) Smart Meters Programme Schedule 2.3 (Standards) (CSP South version) Schedule 2.3 (Standards) (CSP South version) Amendment History Version Date Status v.1 Signature Date Execution copy SCHEDULE 2.3 STANDARDS

More information

ExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF

ExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF Data Sheet Highlights Compact Quad Small Form-factor Pluggable (QSFP28) products for high density 100Gb Ethernet applications Hot swappable, field serviceable modular interfaces for Extreme Networks switches

More information

Reach your objectives without interference

Reach your objectives without interference Reach your objectives without interference Our electromagnetic compatibility (EMC) testing and certification services TÜV SÜD Product Service GmbH Making waves: High EMC standards The risk of electromagnetic

More information

CEMASTER. Advanced Test Equipment Rentals ATEC (2832)

CEMASTER. Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) THERMO VOLTEK EMC COMPLIANCE CEMASTER THE COMPLETE COMPLIANCE-LEVEL TESTER FOR UP TO SIX EMC IMMUNITY STANDARDS Overview

More information

Wireless Module Integration. Michael Lowry TÜV SÜD Product Service

Wireless Module Integration. Michael Lowry TÜV SÜD Product Service Wireless Module Integration Michael Lowry TÜV SÜD Product Service Slide 1 Who am I? Name Michael Lowry Title: Commercial Manager Employer: TÜV SÜD Product Service Experience: Almost 20 years experience

More information

Ascom d62 DECT Handset, Talker

Ascom d62 DECT Handset, Talker Ascom d62 DECT Handset, Talker Features General GAP/CAP compliant DECT handset Upgradeable by licenses Shared Phone 1 Dynamic output power High quality voice Colour display Cleanable, IP 44 Local, central,

More information

FS50W Series LED Driver Input: VAC High Power Factor High efficiency For high bay light IP66 UL CB CE SPECIFICATIONS

FS50W Series LED Driver Input: VAC High Power Factor High efficiency For high bay light IP66 UL CB CE SPECIFICATIONS Product Features: Input Voltage Range:100~277VAC; High Power Factor; Efficiency Up to 86%; Meet UL8750 CB CE; International Protection:IP66; For Outdoor LED lights; 5 Years Warranty; SPECIFICATIONS Model

More information

TCH49IR01 49" Touch Overlay

TCH49IR01 49 Touch Overlay 49" Touch Overlay Transform your display into touch display with this smart addon. Type of Touch Technology Supported Point Infrared (IR) Technology Sensitivity Any touch with finger, gloved hand or pointer

More information

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

ENGINEERING SPECIFICATION SHEET SPEC. Revision History SPEC. Revision History Revision Change Information Date No. Description Current version 2010/08/01 1 New revision Initial 2011-1-25 2 Fuse is changed T4.0A 2.0 2011-4-1 3 Add AC adapter external dimension

More information

Intersil ISL39001C. IEEE a/g WLAN Cardbus32 Card. User Manual. Version 0.1

Intersil ISL39001C. IEEE a/g WLAN Cardbus32 Card. User Manual. Version 0.1 Intersil ISL39001C IEEE 802.11a/g WLAN Cardbus32 Card User Manual Version 0.1 FCC ID: OSZ39001C Page 1 of 10 Table of Contents 0-INTRODUCTION... 3 1-INSTALLATION PROCEDURE... 3 1.1 INSTALLING THE CARDBUS32

More information

TCH65IR01. 65" Touch Overlay

TCH65IR01. 65 Touch Overlay 65" Touch Overlay TOUCH TECHNOLOGY MECHANICAL DIMENSIONS Type of Touch Technology Infrared (IR) Technology Size 1507mm (L) x 882mm (H) x 42mm (D) Supported Point 10 Points Shipping Size 1620mm (L) x 1006mm

More information

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards. 040APS12 B Highlights & Features Safety Approvals to IEC 60601-1 3rd ed. & IEC 60950-1 Risk management report available Low touch current (

More information

Ascom d43 DECT Handset

Ascom d43 DECT Handset Ascom d43 DECT Handset Features TFT Color display High quality voice Wide band audio 3,5 mm headset connector Local, Company, and Central phonebook Voice mail Centralized management Loudspeaking function

More information

ANALYTICAL SERVICES DIVISION, VHG LABS Manchester, NH for technical competence in the field of

ANALYTICAL SERVICES DIVISION, VHG LABS Manchester, NH for technical competence in the field of A2LA has accredited ANALYTICAL SERVICES DIVISION, VHG LABS Manchester, NH for technical competence in the field of Chemical Testing This laboratory is accredited in accordance with the recognized International

More information

CL-9 Linear Fader Controller for the 788T Digital Recorder

CL-9 Linear Fader Controller for the 788T Digital Recorder CL-9 Linear Fader Controller for the 788T Digital Recorder E7556 State Rd. 23 and 33 Reedsburg, WI USA +1 (608) 524-0625 fax: +1 (608) 524-0655 Toll-Free: (800) 505-0625 www.sounddevices.com support@sounddevices.com

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ATC INC Guion Lane Indianapolis, IN Hemi Sagi Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ATC INC Guion Lane Indianapolis, IN Hemi Sagi Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 4037 Guion Lane Indianapolis, IN 46268 Hemi Sagi Phone: 317 328 8492 CALIBRATION Valid To: March 31, 2019 Certificate Number: 2197.01

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 040APS Highlights & Features Compliant to IEC 60601-1 3rd edition IT and medical safety approvals Low earth leakage Current (

More information

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H): 065APS24 B Highlights & Features Safety Approvals to IEC 60601-1 3rd ed. & IEC 60950-1 Risk management report available Low touch current (

More information

WLS-IFC. USB-to-Wireless Interface. User's Guide

WLS-IFC. USB-to-Wireless Interface. User's Guide WLS-IFC USB-to-Wireless Interface User's Guide Document Revision 5A April 2014 Copyright 2014 Trademark and Copyright Information Measurement Computing Corporation, InstaCal, Universal Library, and the

More information

OPSRK150. RK150 Open Pluggable Specification Products

OPSRK150. RK150 Open Pluggable Specification Products RK150 Open Pluggable Specification Products CARACTERISTICI GENERALE CPU RockChip RK3188 Chipset N/A Suport pentru rezoluție Full HDMax.2560x1440 @60Hz GPU MALI- 400 MP GPU up to 600 Mhz Memorie 2 GB

More information

Enclosed Power Supplies

Enclosed Power Supplies , 15 150 Watt Features Very compact metal cased power supplies High operating temperature up to 70 C Low no load power consumption

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CFV SOLAR TEST LABORATORY, INC Ste. A University Blvd. SE Albuquerque, NM 87106

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CFV SOLAR TEST LABORATORY, INC Ste. A University Blvd. SE Albuquerque, NM 87106 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CFV SOLAR TEST LABORATORY, INC. 5600 Ste. A University Blvd. SE Albuquerque, NM 87106 Jim Crimmins (Authorized Representative) Phone: 505 998 0102 Email: Jim.Crimmins@cfvsolar.com

More information

Power Factor Model Number Voltage Voltage

Power Factor Model Number Voltage Voltage LED Driver EUV040SxxxPS 20101014 D Features High Efficiency (Up to 87%) Active Power Factor Correction (Typical 0.92) Constant Output Current Lightning Protection Waterproof (IP66) Dimming Control AllRound

More information

PDD-300 pulsed diode driver

PDD-300 pulsed diode driver rev 1.08 / 2019 02 13 PDD-300 pulsed diode driver User manual Warning! This equipment may be dangerous. Please read user manual before starting operations. Important note. Please measure output with adequate

More information

Cisco XR Router Technical Specifications and Warnings

Cisco XR Router Technical Specifications and Warnings APPENDIXA Cisco XR 12406 Router Technical Specifications and Warnings This appendix provides technical specifications, regulatory information, and translated safety warnings and agency approvals for the

More information

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description 060AAS19 B Highlights & Features Safety Approvals to IEC 60601-1 3rd ed. & IEC 60950-1 Risk management report available Low touch current (

More information

1601 North A.W. Grimes, Suite B Round Rock, TX (512) Fax: (512) January 20, 2012

1601 North A.W. Grimes, Suite B Round Rock, TX (512) Fax: (512) January 20, 2012 1601 North A.W. Grimes, Suite B Round Rock, TX 78665 e-mail: info@ptitest.com (512) 244-3371 Fax: (512) 244-1846 January 20, 2012 Mr. Bobby Wollard Dynamic Flow Computers 12603 Southwest Freeway Suite

More information

China s Certification System for ICT Equipment. Mr. Dabing Ling TL Certification Institute, CAICT

China s Certification System for ICT Equipment. Mr. Dabing Ling TL Certification Institute, CAICT China s Certification System for ICT Equipment Mr. Dabing Ling TL Certification Institute, CAICT 2017-10-30 1 Course Objectives 1 Introduce China s certification system for ICT equipment 2 Provide reference

More information

IF84M60. 84" Interactive Flat Panel Displays

IF84M60. 84 Interactive Flat Panel Displays 84" Interactive Flat Panel Displays PANEL MONITOR CONNECTIVITY H-Freq 270 khz RGB Input VGA In Max. Pixel Freq. 74.25 MHz Video Input HDMI 1.4 + HDMI 2.0 V-Freq 120 Hz Audio Input Line-in Jack Size 84"

More information

TO65DS. 65" TOTEM Displays

TO65DS. 65 TOTEM Displays 65" TOTEM Displays PANEL MONITOR CONNECTIVITY H-Freq 67.5 khz Max. Pixel Freq. 74.25 MHz External Control V-Freq 60 Hz Cabinet T05 Backlight Type EDGE TYPE LED (DUAL STRING) Panel Type a-si TFT Tv Panel

More information

NetSense Core Node EX

NetSense Core Node EX NetSense Core Node EX datasheet Externally mounted NEMA Connector The Sensity Systems Core Node EX is an integral part of our NetSense platform - an open architecture-based light sensory network that can

More information

Re: ENSC 440 Functional Specifications for a World of Warcraft Input Device

Re: ENSC 440 Functional Specifications for a World of Warcraft Input Device February 19, 2007 Lakshman One School of Engineering Science Simon Fraser University Burnaby, BC V5A 1S6 Re: ENSC 440 Functional Specifications for a Dear Mr. One, The enclosed document, Functional Specifications

More information

Test Report. Product Name : Stackable Gigabit Ethernet Switch Model No. : DGS-3224SR, DGS-3324SRI, DGS-3324SR, DPS-500, DPS-900

Test Report. Product Name : Stackable Gigabit Ethernet Switch Model No. : DGS-3224SR, DGS-3324SRI, DGS-3324SR, DPS-500, DPS-900 Test Report Product Name : Stackable Gigabit Ethernet Switch Model No. : DGS-3224SR, DGS-3324SRI, DGS-3324SR, DPS-500, DPS-900 Applicant : D-Link Corporation Address : No. 8, Li-Hsing Seventh Road, Science-Based

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation Location(s) where activities are performed under accreditation Head Office Utrechtseweg 310, Building no. R11 6812 AR Arnhem The Netherlands Location Abbreviation/ location code Utrechtseweg 310, Building

More information

CSU 0111 Compute Sled Unit

CSU 0111 Compute Sled Unit CSU 0111 Compute Sled Unit Ericsson Software Defined Infrastructure Ericsson Compute Sled Unit (CSU) 0111 is a self-managed compute resource designed to slide into the CPA 111 chassis. Four CSUs can fit

More information