1 Spring Test 5 due 4/26/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Where fixed multioutlet assemblies are employed, each feet or fraction thereof of each separate and continuous length shall be considered as one outlet of not less than 180 volt-amperes where the connected appliances are unlikely to be used simultaneously. a. 5 b. 6 c. 8 d. 10 e The principal determinants of operating temperature are. I. heat generated internally in the conductor as the result of load current flow II. the rate at which generated heat dissipates into the ambient medium III. adjacent load-carrying conductors IV. ambient temperature a. II & IV only c. I, II & IV only e. I, II & III only b. I & IV only d. I, II, III & IV f. III & IV only 3. The maximum allowable ampacity of a 750 kcmil XHHW aluminum conductor is amps when there are six current carrying conductors in the raceway, the raceway is installed in a wet location, and the ambient temperature surrounding the raceway is 22 degrees C a b c d Where reduced heating of the conductors results from motors operating on duty-cycle, intermittently, or from all motors not operating at one time, the feeder conductors a. are not allowed to have the ampacity reduced b. may have an ampacity less than specified if acceptable to the authority having jurisdiction c. must be sized not smaller than 125% of the largest motor connected to the feeder d. must be sized not smaller than 125% of the largest motor plus other loads 5. A conductor has a computed ampacity of 75 amps. What is the maximum standard ampere rating of the overcurrent protection device the NEC permits to protect this circuit? This is not a motor circuit or part of a multioutlet branch circuit supplying receptacles. a. 70 amperes b. 75 amperes c. 80 amperes d. 85 amperes 6. If a circuit breaker serves as the controller for a motor, and the motor is not in sight of the breaker, the NEC requires the. a. motor to be less than 2 hp b. breaker be able to be locked in the open position c. motor to be Code letter E d. breaker to have an interrupting rating of 25,000 A 7. shall be placed in all service-entrance motor control centers to isolate service busbars and terminals from the remainder of the motor control center. a. Barriers b. Switches c. Isolators d. Conductors e. Markers 8. Coaxial cable shall be permitted to deliver power to equipment that is directly associated with the radio frequency distribution system if the voltage is not over volts and if the current is supplied by a transformer or other device that has power-limiting characteristics. a. 90 b. 25 c. 70 d. 60 e Among the conductors listed below, all except are permitted to be connected in parallel.

2 a. 250 kcmil b. 2/0 AWG c. 1 AWG d. 1/0 AWG 10. What is the demand load for eighty receptacles located in a 15,000-square-foot office building? a. 180 b. 12,200 c. 14,400 d. 15, The ampacity of conductors is derated when the ambient temperature exceeds ºF. a. 30 b. 72 c. 86 d Communications wires and cables shall be separated at least inches from conductors of any electric light, power, Class 1, non power-limited fire alarm, or medium-power network-powered broadband communications circuits. a. 4 b. 6 c. 24 d. 2 e The installation of a fire alarm system requires a plenum cable to be run above the lay-in ceilings. Which of the following cable types is acceptable? I. CMR II. CMP III. FPLR IV. FPLP a. III or IV only c. I, II, or III only e. III only b. I or III only d. I, II, III, or IV f. II or IV only 14. Where motors are provided with terminal housings, the housings shall be and of substantial construction. I. nonmetallic II. metal a. either I or II b. II only c. I only d. neither I nor II 15. The ampacities provided by the NEC for conductors volts are based on temperature alone and do not take into consideration. a. insulation b. AWG c. CMA d. voltage drop 16. Listed communications cables installed in risers shall be. a. encased in a metal raceway b. located in a fireproof shaft having firestops at each floor c. either a or b d. neither a nor b 17. When conductors of different systems are installed in the same raceway, one system grounded conductor shall be white or gray. The other system grounded conductor shall be. a. green only b. white with an identifying colored stripe that is green c. white with an identifying colored stripe that is not green d. white only 18. For a raceway containing 30 current carrying conductors, the ampacity of each conductor shall be reduced to percent of that for a single conductor. a. 80 b. 70 c. 45 d Which of the following statements about a 2 AWG THHN copper conductor is correct? a. its maximum operating temperature is 90 C b. it has a nylon insulation c. its area is square inches d. it has a DC resistance of ohms per m/ft. 20. A motor control circuit. I. carries electric signals to the controller and carries the main power II. does not carry electric signals to the controller but does carry the main power III. carries the electric signals to the controller but does not carry main power

3 a. I only b. II only c. III only d. none of these 21. What is the area, in square inches, of a 8 AWG bare conductor in a raceway? a b c d For a feeder supplying household cooking equipment and electric clothes dryers, the maximum unbalanced load on the neutral conductor shall be considered as of the load on the ungrounded conductors. a. 40% b. 50% c. 70% d. 80% 23. Thermoplastic insulated fixture wire shall be durably marked with the AWG size, voltage rating and other required markings on the surface at intervals not exceeding inches. a. 6 b. 12 c. 18 d The minimum number of 120-volt, 15-amp lighting branch circuits required for a dwelling that has ft. of livable space is. a. 2 b. 3 c. 4 d The grounded conductor, when insulated, shall have insulation. I. rated not less than 300 volts for solidly grounded neutral systems of 1 kv and over as described in section II. which is suitable, other than color, for any ungrounded conductor of the same circuit on circuits of less than 1000 volts a. I only b. II only c. either I or II d. neither I nor II 26. Determine the maximum current setting permitted for overload protection for a motor that has a thermal protector integral with the motor, given the following information. * 7 1 / 2 hp - wound rotor type * two-phase, 4 wire, AC * 230 volts a. 19 amps b amps c amps d amps 27. A nipple contains six 6 AWG THW copper current-carrying conductors. The ampacity of each conductor would be amperes. a. 65 b. 50 c. 52 d The minimum number of 20-amp, 277-volt, lighting circuits required for a 150,000 ft 2 department store is. The actual connected lighting load is 400 kva. Assume breakers are not rated for continuous use. a. 72 b. 82 c. 91 d For general motor application, the fuse size for the motor branch circuit must be determined from. a. motor nameplate current c. NEC Tables b. NEMA standards d. Factory Mutual 30. A code letter D is marked on a motor nameplate. What is its locked-rotor kva per horsepower? a b c d Where installed in raceways, conductors of size AWG and larger shall be stranded. a. 16 b. 12 c. 10 d. 8 e When calculating the total load on a dwelling, what is the minimum VA that must be added for the two required small-appliance circuits? a VA b VA c VA d VA 33. What is the full load current of a 30 hp, 230-volt, 3-phase, synchronous motor with a 90% power factor? a. 63 amps b amps c amps d amps 34. What is the VA input of a fully-loaded, 5 hp, 230-volt, single-phase motor?

4 a. 746 b. 3,730 c. 6,440 d. 12, For a nonautomatically started motor, the overload protection shall be permitted to be shunted or cut out of the circuit during the starting period of the motor if the device by which the overload protection is shunted or cut out cannot be left in the starting position and if fuses or inverse time circuit breakers rated or set at not over percent of the full-load current of the motor are located in the circuit so as to be operative during the starting period of the motor. a. 140 b. 115 c. 125 d. 130 e Which of the following is not true? a. A demand factor from Table could be applied to a household counter-mounted cooking unit of 1760 watts. b. Ten household clothes dryers have a demand factor of 50%. c. A demand factor from Table could be applied to a 1 3 / 4 kw wall-mounted oven. d. Table is permitted to be used for a branch circuit to a household range. 37. The demand factors of Table apply to the computed load of feeders to areas in hospitals, hotels, and motels where the entire lighting is likely to be used one at a time, as in operating rooms, ballrooms, or dining rooms. a. shall b. shall not 38. Communications cables permitted where installed in vertical runs and penetrating more than one floor, or cables installed in vertical runs in a shaft, shall be Type. I. CMP II. CMG III. CMR a. I only c. III only e. II only b. I or II only d. I, II, or III f. I or III only 39. Table in the 2011 edition of the NEC is used as a reference for underground installations of network-powered broadband communications conductors and cables. a b c d When calculating the load for show window lighting, shall be included for this load. a. 120 VA per outlet c. 200 VA per linear ft. b. 280 VA per outlet d. 180 VA per linear ft. 41. optical fiber cables contain optical fibers and current-carrying electrical conductors. a. Composite b. Nonconductive c. Conductive 42. When using the optional calculation method for a dwelling unit service, all other loads above the initial 10 kw are to be listed at. a. 40% b. 50% c. 60% d. 75% 43. For a dwelling unit served by a single set of 3-wire, 120/240-volt or 208Y/120-volt service-entrance conductors with an ampacity of or greater, it is permissible to compute the feeder and service loads in accordance with (B) and (C) instead of the method specified in Part III of Article 220. a. 175 b. 125 c. 150 d Equipment terminations are permitted to be used with higher temperature-rated conductors at the ampacity of the higher-rated one, provided the equipment is and identified for use with the higher rated conductors. a. listed b. tested c. installed d. rated 45. The grounded conductor of a branch circuit that is 6 AWG or smaller shall be. I. without splices II. white or gray in color a. I only b. neither I nor II c. both I & II d. II only

5 46. Open conductors shall be supported on glass or porcelain knobs,. I. strain insulators II. brackets III. racks a. I only b. II only c. III only d. I, II or III 47. A previously unwired portion of an existing residence or a structural addition to an existing residence, either of which exceeds square feet, shall be computed in accordance with sections and a. 100 b. 250 c. 300 d Synchronous motors of the low-torque, low-speed type, such as are used to drive reciprocating compressors, pumps, and so forth, that start unloaded, do not require a fuse rating or circuit-breaker setting in excess of percent of full-load current. a. 150 b. 200 c. 250 d Ampacity of fixture wire is determined. a. by referring to ampacity Table b. by calculation, using the expected temperature rise of the fixture c. from a table in Article 402 of the Code d. none of these 50. When installing a fire alarm system, survivability cable is typically used in a. a. single-story office building c. hospital b. restaurant d. school 51. The disconnecting means for motor circuits rated 600 volts, nominal, or less, shall have an ampacity rating of at least % of the FLC rating of the motor. a. 100 b. 115 c. 125 d. 135 e Conductors for a motor used in a short-time, intermittent, periodic, or varying duty application shall have an ampacity of not less than the percentages of the motor nameplate current ratings shown in Table. I II III (B) IV (E) a. II only c. I only e. I or II only b. III only d. IV only f. III or IV only

6 Spring Test 5 due 4/26/2013 Answer Section MULTIPLE CHOICE 1. ANS: A 2011 NEC: (H)(1) REF: 2011 NEC: (H)(1) OBJ: Obj Worksheet NAT: Obj ABank 2. ANS: D 2011 NEC: (A)(3) I-Note No.1 & (1) thru (4) REF: 2011 NEC: (A)(3) I-Note No.1 & (1) thru (4) OBJ: Obj Worksheet NAT: Obj ABank 3. ANS: A 385 A 80% 1.05 = amps 2011 NEC: T (B)(2)(a); T (B)(3)(a) & T (B)(16) REF: 2011 NEC: T (B)(2)(a); T (B)(3)(a) & T (B)(16) 4. ANS: B 2011 NEC: REF: 2011 NEC: OBJ: Obj Worksheet 5. ANS: C 2011 NEC: 240.4(B)(2)&(3) & 240.6(A) REF: 2011 NEC: 240.4(B)(2)&(3) & 240.6(A) OBJ: Obj Worksheet 6. ANS: B 2011 NEC: (B) Exc REF: 2011 NEC: (B) Exc OBJ: Obj Worksheet 7. ANS: A 2011 NEC: (E) REF: 2011 NEC: (E) OBJ: Obj Worksheet 8. ANS: D 2011 NEC: REF: 2011 NEC: OBJ: 434 NEC Worksheet 9. ANS: C 2011 NEC: (H)(1) REF: 2011 NEC: (H)(1) NAT: Obj ABank

7 10. ANS: D VA = 14,400 [(10,000) 100%] + [(14,400 10,000) (50%)] = 10, ,200 = 12,200 VA versus 1 VA/SF SF = 15,000 VA 2011 NEC: (K); ; T ; (I) REF: 2011 NEC: (K); ; T ; (I) OBJ: Obj Worksheet NAT: Obj ABank 11. ANS: C 2011 NEC: T (B)(16) REF: 2011 NEC: T (B)(16) OBJ: Obj Worksheet 12. ANS: D 2011 NEC: (A)(2) REF: 2011 NEC: (A)(2) OBJ: 434 NEC Worksheet 13. ANS: F 2011 NEC: T (D) REF: 2011 NEC: T (D) OBJ: Obj Worksheet NAT: Obj ABank 14. ANS: B 2011 NEC: (A) REF: 2011 NEC: (A) 15. ANS: D 2011 NEC: (A)(1) I-Note No. 1 REF: 2011 NEC: (A)(1) I-Note No. 1 OBJ: Obj Worksheet 16. ANS: C 2011 NEC: ; T (a) REF: 2011 NEC: ; T (a) OBJ: 434 NEC Worksheet 17. ANS: C 2011 NEC: 200.6(D) REF: 2011 NEC: 200.6(D) NAT: Obj ABank 18. ANS: C 2011 NEC: (B)(3) I-Note No. 2 REF: 2011 NEC: (B)(3) I-Note No. 2 OBJ: Obj Worksheet 19. ANS: A 2011 NEC: T (A) REF: 2011 NEC: T (A) OBJ: Obj Worksheet NAT: Obj ABank 20. ANS: C

8 2011 NEC: REF: 2011 NEC: OBJ: Obj Worksheet 21. ANS: B 2011 NEC: Ch 9-Table 8 & (C) REF: 2011 NEC: Ch 9-Table 8 & (C) NAT: Obj ABank 22. ANS: C 2011 NEC: (B)(1) REF: 2011 NEC: (B)(1) OBJ: Obj Worksheet 23. ANS: D 2011 NEC: 402.9(A) REF: 2011 NEC: 402.9(A) NAT: Obj ABank 24. ANS: C ( VA) = 6,300 VA 6, = 52.5 amps = circuits 2011 NEC: T REF: 2011 NEC: T OBJ: Obj Worksheet 25. ANS: B 2011 NEC: 200.2(A) REF: 2011 NEC: 200.2(A) NAT: Obj ABank 26. ANS: C 2011 NEC: T with (A)(2) REF: 2011 NEC: T with (A)(2) 27. ANS: A 2011 NEC: (B)(3) I-Note No. 2(2) REF: 2011 NEC: (B)(3) I-Note No. 2(2) 28. ANS: C Per (A), the connected load is used over the demand load when known. Lighting load is continuous, therefore use 125% (1.25) 400, = 500,000 VA 500, = 1,805 amps 1, = ckts 2011 NEC: (A)(1) & (A)

9 REF: 2011 NEC: (A)(1) & (A) OBJ: Obj Worksheet NAT: Obj ABank 29. ANS: C 2011 NEC: 430.6(A)(1) & (C)(1) REF: 2011 NEC: 430.6(A)(1) & (C)(1) 30. ANS: D 2011 NEC: T (B) REF: 2011 NEC: T (B) OBJ: Obj Worksheet 31. ANS: D 2011 NEC: (C) REF: 2011 NEC: (C) OBJ: Obj Worksheet NAT: Obj ABank 32. ANS: D 2011 NEC: (A) REF: 2011 NEC: (A) OBJ: Obj Worksheet 33. ANS: B Due to 90% power factor = NEC: T REF: 2011 NEC: T ANS: C 2011 NEC: T REF: 2011 NEC: T ANS: E 2011 NEC: (A) REF: 2011 NEC: (A) 36. ANS: C 2011 NEC: ; T REF: 2011 NEC: ; T OBJ: Obj Worksheet 37. ANS: B 2011 NEC: T *Note (below table) REF: 2011 NEC: T *Note (below table) OBJ: Obj Worksheet NAT: Obj ABank 38. ANS: F 2011 NEC: & T (a) REF: 2011 NEC: & T (a) OBJ: 434 NEC Worksheet 39. ANS: A 2011 NEC: (C)

10 REF: 2011 NEC: (C) OBJ: 434 NEC Worksheet 40. ANS: C 2011 NEC: (G)(2) REF: 2011 NEC: (G)(2) OBJ: Obj Worksheet NAT: Obj ABank 41. ANS: A 2011 NEC: REF: 2011 NEC: OBJ: 434 NEC Worksheet 42. ANS: A 2011 NEC: (B) REF: 2011 NEC: (B) 43. ANS: D 2011 NEC: (A) REF: 2011 NEC: (A) OBJ: Obj Worksheet 44. ANS: A 2011 NEC: REF: 2011 NEC: ANS: D 2011 NEC: 200.6(A)(1) & (2) REF: 2011 NEC: 200.6(A)(1) & (2) NAT: Obj ABank 46. ANS: D 2011 NEC: REF: 2011 NEC: NAT: Obj ABank 47. ANS: D 2011 NEC: (A)(1) REF: 2011 NEC: (A)(1) OBJ: Obj Worksheet 48. ANS: B 2011 NEC: T Note 3 REF: 2011 NEC: T Note 3 OBJ: Obj Worksheet 49. ANS: C 2011 NEC: REF: 2011 NEC: ANS: C Best guess general knowledge REF: Gen Knowledge OBJ: Obj Worksheet

11 NAT: Obj ABank 51. ANS: B 2011 NEC: (A) REF: 2011 NEC: (A) OBJ: Obj Worksheet 52. ANS: D 2011 NEC: (E) REF: 2011 NEC: (E) OBJ: Obj Worksheet

Spring Test 9 due 05/11/2013

Spring Test 9 due 05/11/2013 Spring Test 9 due 05/11/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. A grounding electrode is. a. a solid conductor b. a circuit conductor that

More information

Spring Test 16 due 06/14/2013

Spring Test 16 due 06/14/2013 Spring Test 16 due 06/14/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. Figure 234.142 1. Refer to the information shown in Figure 234.142. Motor 1

More information

Spring Test 13 due 06/14/2013

Spring Test 13 due 06/14/2013 Spring Test 13 due 06/14/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. The power supply to the mobile home shall be a feeder assembly consisting

More information

Spring Test 17 due 06/14/2013

Spring Test 17 due 06/14/2013 Spring Test 17 due 06/14/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. The NEC defines cable as a cylindrical assembly composed of a conductor centered

More information

Fall Test 21 due 12/11/2012

Fall Test 21 due 12/11/2012 Fall Test 21 due 12/11/2012 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Emergency system transfer equipment, including automatic transfer switches,

More information

Entry Level Assessment Blueprint Electrical Occupations

Entry Level Assessment Blueprint Electrical Occupations Entry Level Assessment Blueprint Electrical Occupations Test Code: 3029 / Version: 01 Specific Competencies and Skills Tested in this Assessment: Safety Apply shop safety rules and ergonomics Explain fire

More information

Electrical Plan Review

Electrical Plan Review Electrical Plan Review Overcurrent Protection and Devices, Short-Circuit Calculations, Component Protection, Selective Coordination, and Other Considerations Table of Contents Part I: Overcurrent Protection

More information

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D. Electrical Integration of PV Systems Ridha Hamidi, Ph.D. 1 Many articles in the NEC are applicable to the electrical integration of a PV system, particularly Article 690. 2 The NEC defines the various

More information

R-LB R-LX Series Installation, Operation & Maintenance Manual

R-LB R-LX Series Installation, Operation & Maintenance Manual Installation, Operation & Maintenance Manual WARNINGS Safety First Hazardous Voltage & Shock Hazard Only qualified licensed electricians should install or service SPDs Hazardous voltages exist within SPDs

More information

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker

More information

Page 1 of 34

Page 1 of 34 www.garyklinka.com Page 1 of 34 Instructions: Fee $65 1. Print these pages. 2. Circle the correct answers and transfer them to the answer sheet. 3. Page down to the last page for the verification forms

More information

AIR COOLED MODULAR RECTIFIER

AIR COOLED MODULAR RECTIFIER CONTROLLED POWER COMPANY SPECIFICATIONS AIR COOLED MODULAR RECTIFIER Spc1800a1 5JAN1999 SPECIFICATION S-1800-A MODULAR (REMOVABLE AND NON-REMOVABLE MODULES) AIR COOLED RECTIFIER Standard output power range:

More information

Introduction to the Inspection Checklist for Rooftop Solar Photovoltaic (PV) Systems in Goshen, IN

Introduction to the Inspection Checklist for Rooftop Solar Photovoltaic (PV) Systems in Goshen, IN Introduction to the Inspection Checklist for Rooftop Solar Photovoltaic (PV) Systems in Goshen, IN This Inspection Checklist for Rooftop Photovoltaic (PV) Systems is based on the Model Inspection Checklist

More information

Application Techniques CENTERLINE 2100 Motor Control Centers

Application Techniques CENTERLINE 2100 Motor Control Centers POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product

More information

Electrical Components and Equipment for General Use Self Inspection Checklist

Electrical Components and Equipment for General Use Self Inspection Checklist Name of School: Optional Information Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Electrical Components and Equipment for General Use Self Inspection Checklist Guidelines:

More information

The purpose of this document is to specify the power requirements for Core Health and Fitness LLC equipment.

The purpose of this document is to specify the power requirements for Core Health and Fitness LLC equipment. Power Requirements Applies to: All Machines The purpose of this document is to specify the power requirements for Core Health and Fitness LLC equipment. Latest Rev. Attention: Obtain the assistance of

More information

CERTIFIED TEST REPORT

CERTIFIED TEST REPORT CP No.: CP1120 Rev. 1 Page: 1 of 24 CERTIFIED TEST REPORT Cooper Power Systems 15 kv Class 600 Amp CLĒĒR TM LOADBREAK SEPARABLE CONNECTOR SYSTEM REV. 1 DATE September 1, 2011 ORIGINAL REPORT DATE: July

More information

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...

More information

Page 1 of 149 First Revision No. 50-NFPA 79-2012 [ Global Input ] Delete the parenthetical terms used to describe IEC terms that follow terms used in NFPA 79 such as "protective bonding". Add information

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section. SECTION 16420 - ELECTRICAL EQUIPMENT PART 1 - GENERAL 1.01 RELATED DOCUMENTS The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified

More information

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM> SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General

More information

1-Line Load Calculation Software. User s Manual APPROVED. Copyright 2013 Durand & Associates. Page 1

1-Line Load Calculation Software. User s Manual APPROVED. Copyright 2013 Durand & Associates. Page 1 1-Line 2014 Load Calculation Software User s Manual APPROVED Copyright 2013 Durand & Associates Page 1 1-LINE 2014 COPYRIGHT 2013 - DURAND & ASSOCIATES This software and manual are protected by Federal

More information

Meter Enclosure and Equipment Standards

Meter Enclosure and Equipment Standards Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1993 Specifications CSJ s 0924-06-221,etc. & 0924-06-223 SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1. Description. This specification describes the minimum acceptable requirements for a weatherproof

More information

SECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 26 27 26 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Stalking the Elusive and Somewhat Strange PV System

Stalking the Elusive and Somewhat Strange PV System A series of articles on photovoltaic (PV) power systems and the National Electrical Code by John Wiles PERSPECTIVES ON PV Stalking the Elusive and Somewhat Strange PV System Photo 1. Framed PV modules

More information

Emery County Senior Center Green River 06/07

Emery County Senior Center Green River 06/07 SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Why is my AFCI tripping?

Why is my AFCI tripping? www.garyklinka.com Page 1 of 21 Instructions: Fee $25 1. Print these pages. 2. Use the included information located on pages 12-20 to answer the 61 questions below. 3. Circle the correct answers and transfer

More information

NEC 2008 Code Changes Top 20 Revisions. By: Rafi Wartan, PE, LEED AP

NEC 2008 Code Changes Top 20 Revisions. By: Rafi Wartan, PE, LEED AP NEC 2008 Code Changes Top 20 Revisions By: Rafi Wartan, PE, LEED AP #1 Article 210.4 MULTIWIRE BRANCH CIRCUITS The rule on simultaneous disconnecting means requirements for multiwire branch circuits was

More information

UNDERCARPET CABLING SYSTEM For Power and Communications

UNDERCARPET CABLING SYSTEM For Power and Communications UNDERCARPET CABLING SYSTEM For Power and Communications Linking Everything Together Power, Voice, and Data December 5, 2007 Undercarpet Cabling System Overview What is Undercarpet Cabling? Primary Applications

More information

Residential 1-Line Multifamily Instructions. User s Manual APPROVED. Copyright 2016 Durand & Associates. Page 1

Residential 1-Line Multifamily Instructions. User s Manual APPROVED. Copyright 2016 Durand & Associates. Page 1 Residential 1-Line 2017 Multifamily Instructions APPROVED User s Manual Copyright 2016 Durand & Associates Page 1 Using Residential 1-Line 2017 with Excel Excel 1997-2003 This product was designed with

More information

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM 1993 SPECIFICATIONS CSJ 1685-05-068, ETC. & 1685-02-042 1.0 DESCRIPTION SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM THIS ITEM DESCRIBES THE OPERATION AND INSTALLATION OF AN ARTERIAL

More information

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis. A21 DIMMER CABINET SPECIFICATION. GENERAL. A.) Overview. 1.) The dimmer cabinets shall be fully digital, designed specifically for architectural and entertainment lighting applications, and shall consist

More information

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death. Installation/Operation Manual TABLE OF CONTENTS Page UNPACKING AND INSTALLATION Unpacking and Preliminary Inspection...2, 3 Model Number...9 LOCATION CONSIDERATIONS Environment, Equipment Performance,

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options

More information

Second Revision No. 1-NFPA [ Global Comment ]

Second Revision No. 1-NFPA [ Global Comment ] Second Revision No. 1-NFPA 79-2017 [ Global Comment ] *************GLOBAL INSTRUCTION - COMP: See Mark's note for clarity*************** Remove all parenthetical terms of (plug/socket) and any variation

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual APC 2X Series Hardwire Products PMP2X-A PMF2X-A PMG2X-A PMH2X-A APC hardwired products are designed to provide specification-grade performance at the service entrance,

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS - For use with CONTROLTrack System Only When installing or using this track system, basic safety precautions should always be

More information

More Questions from Inspectors Numerous PV Systems Pose Issues

More Questions from Inspectors Numerous PV Systems Pose Issues Perspectives on PV More Questions from Inspectors Numerous PV Systems Pose Issues by John Wiles 76 IAEI NEWS March. April 2012 www.iaei.org Photovoltaic (PV) systems prices continue to drop and inspectors

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe

More information

MFJ-1164B AC Line RFI Filter

MFJ-1164B AC Line RFI Filter Introduction MFJ-1164B AC Line RFI Filter Thank you for purchasing the MFJ-1164B AC Line RFI Filter. This is a versatile AC Filter that can be used with all types of sensitive equipment that needs AC line

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

Avanti HP Series Centrifuges Preinstallation

Avanti HP Series Centrifuges Preinstallation J3HP-TB-001AC May 2009 Avanti HP Series Centrifuges Preinstallation INTRODUCTION Purchase of an Avanti HP series high performance centrifuge includes installation and Basic Instrument Training for two

More information

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing Understanding SCCR What is SCCR? When it comes to industrial machinery, it s critical to ensure that electrical panels are designed and built with the proper SCCR to maintain the system, eliminate downtime

More information

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2 The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results

More information

Instruction Manual HPH-8

Instruction Manual HPH-8 Specifications HPH-8 Trigger cable 120-volt, Nema 1-15 Main Power 50-amps @ 240-volt AC Power receptacles (4) Nema 5-15 or 6-15 Maximum HID wattage 8000 watts (on 240-volt) 4800 watts (on 120-volt) Maximum

More information

File E Project 05NK Issued: Revised: REPORT CLASSIFIED FOR USE WITH SPECIFIED EQUIPMENT (XUPD)

File E Project 05NK Issued: Revised: REPORT CLASSIFIED FOR USE WITH SPECIFIED EQUIPMENT (XUPD) File E248748 Project 05NK27956 Issued: 2007-11-01 Revised: 2009-12-04 REPORT on SURGE PROTECTIVE DEVICES/PANELBOARD EXTENSION MODULES, CLASSIFIED FOR USE WITH SPECIFIED EQUIPMENT (XUPD) GE ZENITH CONTROLS

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North

More information

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC. [Refer to Engineering Notes at End of Spec] Section [16XXX] [264XXX] - SURGE PROTECTIVE DEVICES (SPDs) PART 1 - GENERAL 1.1 SCOPE A. This section includes Surge Protective Devices (SPDs) for low-voltage

More information

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS SECTION 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Nameplates. 2. Labels. 3. Wire markers. 4. Conduit markers. 5. Underground Warning Tape. 6. Lockout

More information

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits Course Details Date: January 28 January 31, 2019 Time: 8:00 A.M. - 4:30 P.M. Capacity: 12 attendees Provider: National Technology

More information

E-Series General Specifications

E-Series General Specifications -Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire

More information

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158 Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70

More information

1. Coordination of series-rated devices is permitted where indicated on Drawings.

1. Coordination of series-rated devices is permitted where indicated on Drawings. SECTION 16055 - OVERCURRENT PROTECTIVE DEVICE COORDINATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

IEC H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and

IEC H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and IEC 60309 H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and amperage to prevent interchangeability of voltages Watertight

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation SECTION 26 24 16 PANELBOARDS PART 1 -GENERAL 1.1 SUMMARY A. Section includes distribution and branch circuit panelboards, electronic grade branch circuit panelboards, [and load centers]. 1.2 REFERENCES

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase

More information

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.

More information

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC. [Refer to Engineering Notes at End of Spec] Section [16XXX] [264XXX] - SURGE PROTECTIVE DEVICES (SPDs) PART 1 - GENERAL 1.1 SCOPE A. This section includes Surge Protective Devices (SPDs) for low-voltage

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors

More information

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC The PCI Series Phase Angle Fired SCR Power Controls 25-1200 AMPS 120-600 VAC Precise power control for complex SCR applications. ROBICON 1996 Distributed Worldwide by www.mcgoff-bethune.com Applications

More information

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see

More information

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SED2 VFD NEMA Type 3R Bypass/Air Conditioner SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications

More information

APL/UPL, 205/295 Series Magnetic Circuit Protectors

APL/UPL, 205/295 Series Magnetic Circuit Protectors APL/UPL, 205/295 APL/UPL, 205/295 Series Magnetic Circuit Protectors Introduction 68 Single & Multi-Pole 69 Barriers 7 Configurations 72 Operating Characteristics 74 Delay Curves 75 Specifications 80 Decision

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

Standards Update Notice (SUN) Issued: July 28, 2017

Standards Update Notice (SUN) Issued: July 28, 2017 Standard Information Standard Number: CSA C22.2 No. 107.1 Standard Name: Power conversion equipment Standard Edition and Issue Date: 4 th Edition Dated June 2016 Date of Issue: June 2016 Date of Previous

More information

File Ref: CP No.: CP1205 Rev. 0 Page: 1 of 25 CERTIFIED TEST REPORT. Cooper Power Systems. 28 kv Class 600 Amp 16.2 / 28.

File Ref: CP No.: CP1205 Rev. 0 Page: 1 of 25 CERTIFIED TEST REPORT. Cooper Power Systems. 28 kv Class 600 Amp 16.2 / 28. CP No.: CP1205 Rev. 0 Page: 1 of 25 CERTIFIED TEST REPORT Cooper Power Systems 28 kv Class 600 Amp CLĒĒR TM LOADBREAK SEPARABLE CONNECTOR SYSTEM REV. 0 DATE May 3, 2012 ORIGINAL REPORT DATE: May 3, 2012

More information

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP Bulletin Control Circuit and Load Protection Product Overview Bulletin -MC -MCGA, -MCEA -SP Type Branch Ground Fault Detection Features /V, V & Y/V rating A interrupt / in. per pole wide... A @ UL Circuit

More information

The Real Impact of High Power PoE on Your IP Network

The Real Impact of High Power PoE on Your IP Network The Real Impact of High Power PoE on Your IP Network Jason Finnegan, Product Manager Copper Solutions, Legrand Cindy Montstream, Director of Technical Support & Training, Legrand Amir Sekhavat, Global

More information

Brasch Washdown Unit Heaters

Brasch Washdown Unit Heaters Brasch Washdown Unit Heaters Standard Features: Up to 48 KW Up to 400 Volts Disconnect switch with enclosure interlock Heavy-duty 304 stainless steel shroud Nema 4x non-metallic control panel 24-volt

More information

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection... .3 Product Description Drawout molded case circuit breaker switchboard Front accessible Front connected Through-the-door design drawout mechanism through 600A Insulated case UL 89 breakers up to 200A Visual

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225 A, 8 to 42

More information

8 Submersible Motors Standard

8 Submersible Motors Standard Applications These motors are built for dependable operation in vertical 8 diameter or larger water wells. Basic Features Double Flanged NEMA mounting design Stainless steel splined shaft StatorShield

More information

It is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template.

It is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template. 6. ENGINEERING SYSTEMS REQUIREMENTS G40 SITE ELECTRICAL UTILITIES SYSTEMS REQUIREMENTS SITE ELECTRICAL UTILITIES TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT

More information

UL 508 A standard-compliant design of industrial control panel

UL 508 A standard-compliant design of industrial control panel UL 508 A standard-compliant design of industrial control panel Axel Jöhnke System Architecture Expert 14-15 SEPTEMBER 2011, MUNICH Agenda www.infoplc.net Origin and Comprehension Organizations Certificates

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist TES A. Roads-Service, Lanes Common Items Trails and service roads provide adequate access to buildings for maintenance B. Testing Results-provided to the local government construction representative Data

More information

CITY OF BOISE SPECIFICATIONS FOR LIGHT EMITTING DIODE (LED) STREET LIGHTING Effective 1 Feb, 2018

CITY OF BOISE SPECIFICATIONS FOR LIGHT EMITTING DIODE (LED) STREET LIGHTING Effective 1 Feb, 2018 CITY OF BOISE SPECIFICATIONS FOR LIGHT EMITTING DIODE (LED) STREET LIGHTING Effective 1 Feb, 2018 1. LIGHT EMITTING DIODE (LED) LUMINAIRES FOR ROADWAY TYPE 3 ILLUMINATION A. Testing and Compliance I Manufacturer

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: Members of the NEC-Code Making Panel 3 FROM: Jean

More information

SECTION WIRING DEVICES

SECTION WIRING DEVICES SECTION 16141 WIRING DEVICES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

High Voltage terminations and splice combinations with installed GCA kits were performance tested for this evaluation.

High Voltage terminations and splice combinations with installed GCA kits were performance tested for this evaluation. I. OBJECTIVE To demonstrate the functional performance of Raychem's type GCA Ground Clamp Assembly when applied to copper tape shielded cables subjected to thermal cycling, shield short-circuit and tensile

More information

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A POWER DISTRIBUTION JK Series Solid State Starters Medium Voltage 200-400-600-720A SOLID STATE STARTER JKSSS4+ Series The JKSSS Series of motor starter is the result of extensive research and development.

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

ETAP PowerStation 4.0

ETAP PowerStation 4.0 ETAP PowerStation 4.0 User Guide Copyright 2001 Operation Technology, Inc. All Rights Reserved This manual has copyrights by Operation Technology, Inc. All rights reserved. Under the copyright laws, this

More information

NOTICE. Operating Instructions 150W Power Pack. How to Calculate Wattage Load for 150W Power Pack EXAMPLE

NOTICE. Operating Instructions 150W Power Pack. How to Calculate Wattage Load for 150W Power Pack EXAMPLE NOTICE Warning: Risk of Fire or Electrical Shock Install the power unit 5 feet (1.5 m) or more from a pool, spa, or fountain. Where the power unit is installed (a) indoors within 10 feet (3.0m) of a pool,

More information

File E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7)

File E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7) File E3456 Project 08NK10151 November 24,09 REPORT ON TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7) *********************************************************** Complementary Product Category ELECTROMAGNETIC

More information

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring User Manual JS-ICON 624 PACK Portable Dimmer Pack JOHNSON SYSTEMS INC. Spring 2007 Table of Contents JS-ICON 624 DMX JS-ICON 624 CC 6-2.4kW Dimming Strip JS-ICON 624 ND 6-2.4kW Relay Strip Introduction...3

More information