1 GRAVIMETRIC GATEWAY PRE-SALES SUPPORT DOCUMENT December 3, 2003 Computer Communications Maguire Products Inc. 11 Crozerville Road Aston PA, COPYRIGHT MAGUIRE PRODUCTS, INC. 2003

2 Table of Contents: Introduction 3 G2 Server / G2 Client System Requirements 4 Part List Overview 5 MLAN Network Parts Diagram 6 Startup Quick Overview 7 Wiring Your Own MLAN 8 Advanced Network Options Using Ethernet 11 General Contact Information 14

3 Introduction Gravimetric Gateway Software and the MLAN *** Communications Network Pre-Sales Support Document This document is intended to provide you with the information you will need to set up the Gravimetric Gateway program s communication network in the field. The Gravimetric Gateway program or referred to as G2, was designed to provide enhanced access and control of the Maguire Weigh Scale Blenders with material usage tracking reports and monitoring, remote access of the basic control settings, such as recipes (materials and settings), work order numbers, and operator numbers as well as advanced features like Advanced Inventory Management (AIMS) and Extrusion Control. Before the Gravimetric Gateway can connect to the Maguire Weigh Scale Blenders, a communication network must be installed and tested. This document will outline your options in the layout of this communication network. For additional information on the Gravimetric Gateway software see or call Weigh Scale Blender (WSB) controllers can communicate over two different protocols, MLAN and RS232. Both are available at the DB9 port on the WSB controller. In a typical installation MLAN should be used in all factory installations. RS-232 may be used in lab testing; limited applications or short distances to Serial to Ethernet converters (G2-ES) but is NOT recommended for factory installations. If you are communicating over a distance greater than 50 feet or with more than one WSB then you must use the G2 Signal Amplifier (G2-SA). It utilizes optically isolated couplers for all communication lines to reduce the potential of noise and other electrical interference from entering the computer circuitry. The G2-SA also converts RS-232 communications to MLAN. The G2-SA also serves as a licensing security key and is required to be connected The Gravimetric Gateway Server can communicate to the Maguire weigh scale blenders either through serial using an available COM port on the G2 Server computer, and/or through Ethernet. Ethernet communications to the WSBs require either the use of an Ethernet to Serial converter (G2-ES-x) located at the controller(s) or the use of the Satellite COM Server, which uses a shared COM port of a computer other than the G2 Server PC. *** MLAN refers to Maguire Local Area Network. MLAN is one of two communication protocols used to communication with the Maguire Weigh Scale Blenders. In this document, MLAN does not refer to MLAN for Windows, which is an earlier version of communications software for use with the Maguire Weigh Scale Blenders.

4 G2 Server / G2 Client System Requirements Hardware and operating system requirements for the installation of the G2 Server and the G2 Client Software Computer System Requirements IBM-PC or Compatible (Pentium 233 or faster). We recommend that the G2 Server computer be dedicated to the purpose of collecting data for G2. Constant COM port communication between the G2 Server and the Maguire Weigh Scale Blenders may cause a noticeable lag in the processor when using the G2 Server computer for additional functions while the G2 Server is collecting data. Minimal HD Space 6 Gigabyte Hard Drive or larger for long term data collection Video Super VGA 1024 x 768 resolution recommended, 800 x 600 acceptable Memory Minimum 64 MB, preferably 128 MB or more Ports 2 available serial ports (1 port for mouse if no PS2 port available, 1 port for MLAN), 1 available printer port if printing reports is desired. Mouse PS2 preferable Operating System Recommendations G2 Server Windows NT/2000/XP G2 Clients Windows 95/98/ME/NT/2000/XP Windows NT, Windows 2000 and Windows XP are recommended for G2 Server Installations. Windows 95/98/ME not recommended for the G2 Server. G2 Clients can be installed on Windows 95/98/ME providing they are connecting to a G2 Server that is running on a Windows NT, 2000, or XP operating system. These recommendations are recommended but not required. G2 Server will run under Windows 95, 98, or ME however problems may arise due to the lack of long term stability of Windows 95, 98, and ME. If the G2 Server will run constantly for prolonged periods of time without a computer shutdown or re-boot, we recommend that the G2 Server be installed on a Windows NT, Windows 2000 or Windows XP system.

5 Parts list overview for implementing the G2 Server and the Maguire Local Area Network (MLAN) Please see diagrams below for details on what parts you may need to assemble your network. Part Number G2-SK G2-SA G2-SL G2-SLU MLAN-SE G2-SE G2-IR G2-D G2-C G2-CA G2-CB G2-ES-11 G2-ES-12 G2-DEMO G2-MR G2-SU G2-WU G2-PC Description G2 Starter Kit This consists of the following items: G2-SA, one G2-SL (single blender license), Latest available version of the G2 Installation CD-ROM and a G2 manual (also available on the installation CD-ROM). See below for explanation of each item in the G2-SK. Signal Amplifier for G2 communication. The G2-SA Includes a built-in security key. The security key can be re-programmable for additional licenses (seats) and added features through use of a Certificate License purchased from Maguire Products or your Maguire representative. Software License for addition WSBs. If the customer already has a G2-SA, a Certificate will be issued to enable communication to additional blenders. The certificate number can be entered into the G2 Client software to apply the update of additional licensed blenders. Software License UNLIMITED WSB COUNT Single Extender (may be referred to as a G2-SE) Used to boost the signal strength, may be placed in-line on the communication network at a distance of several hundred feet from the G2 Server 100' Initial Cable Run w/db9 Connector 20' Cable Drop w/db9 Connector Cable per foot (for run through ceiling) sold by the foot Cable Adapter for single blender communication or testing (includes G2 Lite) See Foot Note Connector Box for G2 network Ethernet to Serial converter Single COM port, 110 volt Ethernet to Serial converter Single COM port, 220 volt G2 Installation CD-ROM - May be used for G2 version updates, Demonstration or full installations. Maintenance Release CD-ROM Software Version Update CD-ROM MLAN to G2 License Upgrade converts MLAN licenses to G2 (includes starter kit). Upgrades WSB license count only, Not Data Conversion Pre-configured Desktop or rack mount G2 computer (call for quote, please specify desktop, rack mount, or other computer requirements)

6 Notes on Parts Listing: Depending on the layout you choose to use, some of the parts listed below are not required. You, the customer, may assemble the communication network to the blenders using off the shelf cable, junctions and DB-9 cable ends. It is recommended that you use available parts and cable equal to the specifications within this document. Refer to the wiring diagram at the end of this manual for a wiring example and the pin configuration. Otherwise you may purchase pre-terminated cables listed in the parts list to assemble the communications network. MLAN Network Parts Diagram This diagram outlines a typical MLAN structure. Use this diagram in conjunction with the parts listing above to help map out cable length (MLAN-IR, MLAN-C), number of connector boxes (MLAN-CB) and drops (MLAN-C) you will require for your application before placing your order.

7 Startup Quick Overview Basic Configuration - What You Need The basic layout of a MLAN communications network will depend on the distance from the G2 Server to the Blender(s) and the number of blenders. The basic requirements are as follows: 1. G2 Starter Kit (G2-SK, includes one G2-SL) 2. One G2-SL per each additional blender 3. One initial run (G2-IR) 4. One 20 drop per blender (G2-D) 5. Enough MLAN cable to wire everything together (G2-C) 6. One connector box per blender (G2-CB) Basic G2 Communication Network Layout

8 Wiring your own Maguire Local Area Network (MLAN) For those of you that would like to make up your own cables follow these instructions: MLAN TO CONTROLLER CABLE PINOUT MLAN-IR DB9 Connector pin (or terminal strip) Wire Color MLAN-D DB9 Connector pin 1 Black 1 4 Red 4 6 White 6 7 Green 7 5 Shield connected to hood The shield is connected at all points including at the controller. At the controller the shield should be connected to the housing of the controller. This shield is intended to tie all external noise to ground at the MLAN-SA or the computer, while minimizing the chance of noise entering the WSB controllers. The shield is not connected to pin 5 of the controller; however, it is connected at the computer. MLAN requires four (4) conductor cable with a shield for conveying information. Wire size should be 18 to 22 gauge. Use 18 gauge for the long runs (especially over 500 feet). Twentytwo (22) gauge is recommended for the drops to each controller. Twenty-two (22) gauge wire is used at each controller termination because it solders more easily to the DB9 connector required at each WSB controller location. We recommend: CAROL WIRE, Part #C2555 or BELDON WIRE, Part #9402 Conductors are Black, Red, White, and Green, plus a shield. Black is the positive power supply (16 to 24 volts) Red is the neutral from the power supply White is communication from PC to WSB controller Green is communication from WSB controller to PC Wiring generally requires a single cable run through the ceiling over all the process machines with drops to each controller. This main wire may T off to other locations if required for more efficient wiring. RS-232 Communication (for limited applications) RS-232 uses a direct connection from the computer to the WSB controller. This type of communication is reliable for short runs where little or no noise or static interference is present. This may be the case in a lab or another closely controlled environment. A low noise environment is not common in a factory and we do NOT recommend RS-232 for factory installation. Other restrictions are that the computer must be close (less than 50 feet) to the WSB controller and can only communicate with a few units (maximum of three). If all three conditions are met, then you may cable directly to the RS-232 serial port on your computer without any other

9 hardware interface. Under these circumstances, the MLAN-SA is not required. The proper pin connections are as follows: RS-232 TO WSB CONTROLLER CABLE PINOUT WSB DB9 Connector Computer Connector pin # DB9 or DB and 1 6, 7, 8 4, 5, 6 pins tied together Do NOT use a standard off-the-shelf cable. Standard cables have ALL pins connected, or at least more than just those listed above. ALL pins connected will NOT work. You must wire a special cable according to the diagram provided. Wiring Consideration The wiring of your communication lines is very important for reliable operation. To minimize problems, consider the following: 1. Communication lines are low voltage lines. Be sure that these lines are not bundled to any high voltage lines. If you run them in conduit, do not run high and low voltage lines together. 2. It is not necessary to run this wire in conduit. If you do run cables without conduit, do not wire tie these lines to material conveying lines or other conduit containing high voltage or high amperage electrical lines. 3. Keep all communication lines away from all vacuum loader-conveying lines. Conveying plastic produces extreme static charges. An electrical line, even in conduit that runs next to a vacuum line can introduce extreme static pulses into the processor. Keep these lines separated from conveying lines.

10

11 Advanced Network Options Using Ethernet for Blender Communications An option for communications to the network of blenders is the use of Ethernet to Serial converters. Ethernet to Serial converters can be purchased through Maguire Products as G2- ES-11 (110 volt) and G2-ES-12 (220 volt). The G2-ES is used to convert the RS-232 serial communications port of the Weigh Scale Blender to Ethernet. Communications between the G2 Server and the Weigh Scale Blenders is then achieved through the TCP/IP protocol, over the Ethernet network. Installing an Ethernet network is more complex than a simple RS-232 network and requires knowledge of Ethernet wiring and the use of specialized tools and wiring configuration standards. For that reason, a qualified network technician with an understanding of computer networks and the installation of the TCP/IP protocol may be required. Detailed instructions for G2-ES setup are supplied with each G2-ES unit. REQUIREMENTS: Use of an Ethernet network for G2 communications to one or more Maguire Weigh Scale Blenders requires the following: Each Weigh Scale Blender requires a G2-ES. The G2-ES will be mounted within 6 feet of the Weigh Scale Blender and requires a source of power (110v or 220v) within 6 feet. Models available through Maguire Products are: G2-ES-11 G2-ES-12 Ethernet to Serial converter Single COM port, 110 volt Ethernet to Serial converter Single COM port, 220 volt Recommended Ethernet cable for G2 communications is: Cat5e STP (shielded, twisted pair), 24AGW solid cable. Cat5 is acceptable but has a shorter maximum distance; CAT5 is rated to 100 meters, CAT5e is rated to 350 meters. The Cat5e Ethernet cable must be run from each blender s G2-ES back to the G2 Server. If two or more blenders are in use requiring more than one G2-ES, an Ethernet hub or switch is required as a central junction for all Ethernet cables. All Ethernet cables, including the G2 Server s Ethernet cable, each blender s G2-ES, and any optional G2 Client computers, will be plugged into the Ethernet hub or switch. If only a single blender is in use requiring one G2-ES and one run of Ethernet cable from the G2 Server PC to the G2-ES, a hub or switch is not require however the Ethernet cable must be configured as a crossover type cable. See crossover cable diagram at the end of this document. Each Cat5e cable run should not exceed 350 meters (Cat5 100 meters). If longer lengths are required, use of a repeater may be necessary to maintain signal strength. Stranded cable should not be used due to its significantly limited maximum distance (10 meters, 33 feet). When installing the Ethernet cable, avoid sources of Electro- Magnetic interference (EMI) such as vacuum loader lines, transformers, high voltage lines, florescence lighting, etc.

12 The G2 Server PC must be configured to use the TCP/IP protocol. A Static I.P. address must be assigned to the G2 Server PC if the Server is to be accessed from other PCs on the network using the G2 Client software. Each G2-ES will be assigned a static I.P. address and specific serial settings. Configuration instructions are provided with each G2-ES and are also available online at Each Maguire Weigh Scale Blender must be assigned a unique ID number between 001 and 254 using the *66 function. See your Weigh Scale Blender manual for further instructions on how to set the ID number. Example diagram of a G2 Ethernet Network Key points in the diagram above: Each Maguire Weigh Scale Blender is connected directly to it s own G2-ES through a special Null Modem serial cable (provided with the G2-ES). Each G2-ES includes its own 12-volt transformer and must be supplied power within 6 feet of the G2-ES. All Ethernet cables (Cat5e recommended) are run back to a central location and plugged into an Ethernet hub or switch. The G2 Server PC is also connected to the Hub as well as any optional G2 Client PCs. Connected to the G2 Server s COM Port is the G2-SA. The G2-SA contains the security key, which is required for licensing of more than a single Weigh Scale Blender. The G2-SA is also a signal amplifier, which is used in serial communication applications. In Ethernet applications, the G2-SA is only used as a security key. It is possible to use both a serial and Ethernet network at the same time for G2 communications. Although it is generally not configured in this way, the serial output to Blenders port on the G2-SA can communicate with some blenders while the Ethernet network can communicate with other blenders.

13 Client Only PCs communicate directly with the G2 Server over the Ethernet network via the TCP/IP protocol. Each cable is terminated at both ends with RJ-45 modular connectors designed for shielded, solid cable. Wiring configurations typically are T568B wiring patterns. Note: Ethernet network parts and accessories are not included in the MLAN parts listing but may be special ordered through the developers of G2, Green Bridge Station Technologies. See contact information at the end of this document. Below is a diagram for a crossover type cable that would be used for a direct run from the G2 Server PC s network interface card (NIC), to the G2-ES. This would only be used in a single blender setup where an Ethernet hub or switch would not be necessary.

14 For more information or for additional documents and manuals, visit our web site at the following addresses: General Product information: G2 Server Software: General Contact Information: Maguire Products, Inc. 11 Crozerville Road Aston, PA USA Tel: Fax: If additional G2 support is needed contact: Green Bridge Station Technologies Website: Phone: Fax:

COMPUTER COMMUNICATIONS MLAN Pre-Sales

COMPUTER COMMUNICATIONS MLAN Pre-Sales MAGUIRE Products, Inc. 11 Crozerville Road Aston, PA 19014 tel: 610-459-4300 fax: 610-459-2700 MLAN PRE-SALES SUPPORT DOCUMENT October 15, 1999 Computer Communications MLAN Maguire Local Area Network COMPUTER

More information

G2-ES Configuration Instructions

G2-ES Configuration Instructions G2-ES Configuration Instructions This instructional support document is written for the G2-ES (Gravimetric Gateway Ethernet to Serial Converter), which in this case, is the MOXA NPort Express DE-211 Ethernet

More information

MAGUIRE G2-ES Configuration Instructions for Ethernet to Serial Converter Model: Moxa NPort 5110 Serial Device Server

MAGUIRE G2-ES Configuration Instructions for Ethernet to Serial Converter Model: Moxa NPort 5110 Serial Device Server TECHNICAL INSTRUCTIONS MAGUIRE G2-ES Configuration Instructions for Ethernet to Serial Converter Model: Moxa NPort 5110 Serial Device Server This instructional support document is written for the MOXA

More information

Increasing MLAN Communications Speed Changing Baud Rate

Increasing MLAN Communications Speed Changing Baud Rate Increasing MLAN Communications Speed Changing Baud Rate Maguire Products Inc. March 14, 2003 Increasing the Maguire Weigh Scale Blenders Communication Speed The G2 Server communicates with the Maguire

More information

Gravimetric Gateway Materials Management System. Maguire Products Inc. April 16, Computer Communications for the Maguire Local Area Network

Gravimetric Gateway Materials Management System. Maguire Products Inc. April 16, Computer Communications for the Maguire Local Area Network Gravimetric Gateway Materials Management System Computer Communications for the Maguire Local Area Network Maguire Products Inc. April 16, 2004 This manual has been updated for G2 Version 3.2 Copyright

More information

Gravimetric Gateway Quick Start Tutorial Manual

Gravimetric Gateway Quick Start Tutorial Manual MAGUIRE PRODUCTS INC. GRAVIMETRIC GATEWAY SOFTWARE Gravimetric Gateway Quick Start Tutorial Manual Computer Communications Software for the Maguire Weigh Scale Blenders INSTALLATION OPERATION MAINTENANCE

More information

MAGUIRE PRODUCTS, INC. 11 Crozerville Road Aston, PA tel: fax:

MAGUIRE PRODUCTS, INC. 11 Crozerville Road Aston, PA tel: fax: MAGUIRE PRODUCTS, INC. 11 Crozerville Road Aston, PA 19014 tel: 610-459-4300 fax: 610-459-2700 http://www.maguire.com/ MLAN For Windows Version 1.5 May 8, 1999 Computer Communications for MLAN Maguire

More information

Gravimetric Gateway Materials Management System. Maguire Products Inc. Computer Communications for the Maguire Local Area Network

Gravimetric Gateway Materials Management System. Maguire Products Inc. Computer Communications for the Maguire Local Area Network Gravimetric Gateway Materials Management System Computer Communications for the Maguire Local Area Network Maguire Products Inc. Copyright 2012 Maguire Products Inc. 2 Contents of this Manual How To Use

More information

MLAN Protocol Manual WSB, WST, LIW, MGF, LPD. Maguire Local Area Network MLAN COMMUNICATIONS PROTOCOL. Communications Protocol for

MLAN Protocol Manual WSB, WST, LIW, MGF, LPD. Maguire Local Area Network MLAN COMMUNICATIONS PROTOCOL. Communications Protocol for MAGUIRE PRODUCTS INC. MLAN COMMUNICATIONS PROTOCOL MLAN Protocol Manual Maguire Local Area Network Communications Protocol for WSB, WST, LIW, MGF, LPD Copyright Maguire Products, Inc. 2017 Revision: August

More information

MAGUIRE PRODUCTS, INC. 11 Crozerville Road Aston, PA tel: fax:

MAGUIRE PRODUCTS, INC. 11 Crozerville Road Aston, PA tel: fax: MAGUIRE PRODUCTS, INC. 11 Crozerville Road Aston, PA 1914 tel: 61-459-43 fax: 61-459-27 www.maguire.com BAR CODE DOCUMENTATION Communications Between Maguire MLAN equipment and a Bar Code Scanner BAR CODE

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

CAT5 1500HD EXT-CAT5-1500HD USER MANUAL.

CAT5 1500HD EXT-CAT5-1500HD USER MANUAL. CAT5 1500HD EXT-CAT5-1500HD USER MANUAL www.gefen.com Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday thru Friday PST Write

More information

Cat5 5500HD EXT-CAT5-5500HD USER MANUAL.

Cat5 5500HD EXT-CAT5-5500HD USER MANUAL. Cat5 5500HD EXT-CAT5-5500HD USER MANUAL www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday

More information

LineMaster Loss-In-Weigh

LineMaster Loss-In-Weigh MAGUIRE PRODUCTS INC. EXTRUSION & YIELD CONTROL LineMaster Loss-In-Weigh EXTRUSION CONTROL & YIELD CONTROL INSTALLATION OPERATION Copyright 2007 Edition: February 15, 2007 2 Maguire LineMaster Loss-in-Weigh

More information

CNE301 Network I Lab 04 Building a cross-over cable and configuring back2back network.

CNE301 Network I Lab 04 Building a cross-over cable and configuring back2back network. CNE301 Network I Lab 04 Building a cross-over cable and configuring back2back network. # Student ID Student Name Grade (10) 1-1 / 10 - Build a Crossover Cable Objective Build a Category 5 or Category 5e

More information

NOVATEC/MAGUIRE Blender Selection Guide

NOVATEC/MAGUIRE Blender Selection Guide NOVATEC/MAGUIRE Blender Selection Guide The most popular blenders worldwide Three out of four gravimetric blenders purchased are manufactured by Maguire Products and NOVATEC is proud to be the world's

More information

Cat.8 Shielded Field Termination Plug Description

Cat.8 Shielded Field Termination Plug Description Description RiT s CAT8 Shielded field termination plug are cost-effective building blocks for your cabling system. Meticulously engineered to deliver exceptional performance while streamlining installations.

More information

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): Power Series / 5401

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): Power Series / 5401 Manufacturer: DSC Integration Note Model Number(s): Power Series / 5401 Core Module Version: 4.0 (all builds) Comments: Document Revision Date: 1/30/2013 OVERVIEW AND SUPPORTED FEATURES The DSC Power Series

More information

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): DSC POWER SERIES / IT-100

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): DSC POWER SERIES / IT-100 Manufacturer: DSC Integration Note Model Number(s): DSC POWER SERIES / IT-100 Core Module Version: 6.4.209 Comments: Document Revision Date: 9/11/2013 OVERVIEW AND SUPPORTED FEATURES The DSC Power Series

More information

Cables and Connectors

Cables and Connectors Module 2 Cables and Connectors Twisted Pair Two wires that carry the data signals (one conductor carries a positive signal; one carries a negative signal). Two wires are twisted to reduce the effects of

More information

Mini USB-2 Extender EXT-USB-MINI2N USER MANUAL

Mini USB-2 Extender EXT-USB-MINI2N USER MANUAL Mini USB-2 Extender EXT-USB-MINI2N USER MANUAL Congratulations on your purchase of the Mini USB-2 Extender. Your complete satisfaction is very important to us. Gefen Gefen delivers innovative, progressive

More information

Instrument Configuration Software March dolphin PLUS

Instrument Configuration Software March dolphin PLUS Instrument Configuration Software March 2004 dolphin PLUS Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected

More information

RS485 Network Cabling Standard

RS485 Network Cabling Standard ROLLEASE ACMEDA RS485 Network Cabling Standard August 2017 CONTENTS August 2017 SECTION NO. DESCRIPTION PAGE NO. Section 1 RS485 BUS OVERVIEW 3 Section 2 NETWORK TOPOLOGIES 4 Section 3 DIMENSIONAL LIMITATIONS

More information

Audisey REM-PACK-8. by Intelix

Audisey REM-PACK-8. by Intelix Audisey REM-PACK-8 by Intelix Table of Contents Overview... 3 REM-PACK-8 Contents...3 Wiring the REM-PACK-8... 4 Determing the Cabling Schematic...4 Wiring with Twisted Pair and 18 Gauge Cable...5 Preparing

More information

CAT5 4X Extender. EXT-HDMI-CAT5-4X User Manual.

CAT5 4X Extender. EXT-HDMI-CAT5-4X User Manual. CAT5 4X Extender EXT-HDMI-CAT5-4X User Manual www.gefen.com Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday thru Friday.

More information

USB to Serial Quick Installation Guide

USB to Serial Quick Installation Guide USB to Serial Quick Installation Guide Introducing the USB to Serial The USB to Serial adapter converts one USB port to multiple 9-pin (DB9) serial ports. Features and Benefits Full support for Windows-based

More information

CAT EXT-CAT USER MANUAL.

CAT EXT-CAT USER MANUAL. CAT5 7500 EXT-CAT5-7500 USER MANUAL www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (88) 772-900 (800) 545-6900 Fax (88) 772-920 Technical Support Hours: 8:00 AM to 5:00 PM Monday thru

More information

Chapter 6 Cubix SP1 Blade Server

Chapter 6 Cubix SP1 Blade Server Chapter 6 Cubix SP1 Blade Server Introduction Cubix designed the SP1 Blade Server to fit inside a BladePoint or BladeStation enclosure. The Blade Server features the Intel Pentium 4 processor, the Intel

More information

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual page 2 of 15 Contents: Overview... 2 Models... 3 Power... 4 Probes... 4 Connector identification... 5 Pin-out diagrams... 6

More information

DVI CAT5 4X Extender. EXT-DVI-CAT5-4X User Manual.

DVI CAT5 4X Extender. EXT-DVI-CAT5-4X User Manual. DVI CAT5 4X Extender EXT-DVI-CAT5-4X User Manual www.gefen.com Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday thru Friday.

More information

ADAPTER CARDS TRADITIONAL STANDALONE. DATA SHEET page 1/14. Description

ADAPTER CARDS TRADITIONAL STANDALONE. DATA SHEET page 1/14. Description ADAPTER CARDS DATA SHEET page 1/14 Description Part Numbers AC38A Description High Speed RS485 Repeater 120 VAC The AC38 is an optically-isolated RS-485 repeater. AC38 can operate at up to 115.2K baud

More information

User s Manual Hub444. Motion Control Network Hub

User s Manual Hub444. Motion Control Network Hub 8/23/02 JK User s Manual Motion Control Network Hub Applied Motion Products, Inc. 404 Westridge Drive Watsonville, CA 95076 Tel (831) 761-6555 (800) 525-1609 Fax (831) 761-6544 motors drives controls -2-

More information

CAT U S E R M A N U A L

CAT U S E R M A N U A L CAT5 7500 U S E R M A N U A L www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 884-6294 (800) 545-6900 Fax (818) 884-3108 Technical Support Hours: 8:00 AM to 5:00 PM Monday thru

More information

Model CFA-24 Transparent Cable Farm Automation Switch

Model CFA-24 Transparent Cable Farm Automation Switch Model CFA-24 Transparent Cable Farm Automation Switch Ideal for Broadband Forum s ID-337 Gfast Certification and TR-249 VDSL2 Vectoring Testing High performance transparent solution designed to automate

More information

LGate 120 Installation Guide - Appendix

LGate 120 Installation Guide - Appendix LGate 120 Installation Guide - Appendix This guide contains information on RS485 and Ethernet connections to the LGate 120 3GY Version 1.1 Table of Contents Important Product Information 3 The LGate 120

More information

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F We make no warranties with respect to this documentation and disclaim any implied warranties of merchantability,

More information

ASKING FOR ASSISTANCE

ASKING FOR ASSISTANCE ASKING FOR ASSISTANCE Technical Support: Telephone (88) 77-900 (800) 545-6900 Fax (88) 77-90 Technical Support Hours: 8:00 am to 5:00 pm Monday to Friday Write to: Gefen, Inc. c/o Customer Service 0600

More information

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly. Revised Sept-28-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Instructions CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Kit

More information

Installing the Cisco 2524 and Cisco 2525 Routers

Installing the Cisco 2524 and Cisco 2525 Routers CHAPTER 3 Installing the Cisco 2524 and Cisco 2525 Routers This chapter guides you through the installation of the Cisco 2524 and Cisco 2525 routers and includes the following sections: Required Tools

More information

48-Port 10/100/1000Base-T with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

48-Port 10/100/1000Base-T with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide 48-Port 10/100/1000Base-T with 4 Shared SFP Managed Gigabit Switch WGSW-48000 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5 4. Logon to

More information

Quick Start Guide. 2-Port 10/100 Device Server RS-232/422/485 DB9 M. Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network.

Quick Start Guide. 2-Port 10/100 Device Server RS-232/422/485 DB9 M. Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network. LES302A LES302A-KIT LES302AE-KIT 2-Port 10/100 Device Server RS-232/422/485 DB9 M Quick Start Guide Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network. Customer Support Information

More information

Copyright Black Box Corporation. All rights reserved.

Copyright Black Box Corporation. All rights reserved. Copyright 2000. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 JUNE 2000 SP141A SP501A SP508A SP515A-R2 SP523A-R2 SP604A SP350A-R2 SP502A

More information

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP AX3000 Platine Terminal Ethernet TCP/IP Model 80 Installation Guide January 2012 - Ref: I80E0922-2 Model AX3000/M80 Type EA The reproduction of this material, in part or whole, is strictly prohibited.

More information

Twisted Pair Cable Testers Int l Phone

Twisted Pair Cable Testers Int l Phone Twisted Pair Cable Testers Int l Phone 001.804.550.1121 Main LAN ProNavigator Tester & Remote If you re a technician on the go, you need the LAN ProNavigator from Paladin Tools! Two-piece tester includes

More information

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03 Digital Lighting Systems, Inc. PD26 Two Channel Dimmer and Switch Packs PROTOCOL PD26 S2 S USER'S MANUAL PD26-UM Rev. E - 02/03 Digital Lighting Systems PD26 User's Manual - Page GENERAL DESCRIPTION The

More information

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network

More information

ipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide

ipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide ipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications 2003 Control Technology

More information

I need to protect my equipment against damaging power surges and spikes.

I need to protect my equipment against damaging power surges and spikes. Complex Problems I need a fail safe way to distribute clean power to my system. I need to protect my equipment against damaging power surges and spikes. I need a way to both monitor my electrical system

More information

A+ Guide to Managing & Maintaining Your PC, 8th Edition. Chapter 16 Networking Types, Devices, and Cabling

A+ Guide to Managing & Maintaining Your PC, 8th Edition. Chapter 16 Networking Types, Devices, and Cabling A+ Guide to Managing & Maintaining Your PC, Chapter 16 Networking Types, Devices, and Cabling Objectives Learn about network types and topologies Learn about the hardware used to build local networks Learn

More information

8-Port 10/100Mbps + 2G TP/SFP Combo. Managed Industrial Switch ISW-1022M / ISW-1022MT / ISW-1022MP / ISW-1022MPT / ISW-1033MT

8-Port 10/100Mbps + 2G TP/SFP Combo. Managed Industrial Switch ISW-1022M / ISW-1022MT / ISW-1022MP / ISW-1022MPT / ISW-1033MT 8-Port 10/100Mbps + 2G TP/SFP Combo Managed Industrial Switch ISW-1022M / ISW-1022MT / ISW-1022MP / ISW-1022MPT / ISW-1033MT Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements...

More information

3 Chapter Introduction. 3.2 Copper Cable

3 Chapter Introduction. 3.2 Copper Cable 3 Chapter 3 3.1 Introduction The Network Media is the device that physically carries the data from computer to computer. The three major types of network media are: Copper Cable Fiber-Optic Cable Wireless

More information

WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM Revised 4/30/ Electrical Systems

WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM Revised 4/30/ Electrical Systems SECTION 26 09 13 WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. This section describes the metering, communications, and visualization requirements for a modular, scalable

More information

MGate MB3170/MB3270 Quick Installation Guide

MGate MB3170/MB3270 Quick Installation Guide MGate MB3170/MB3270 Quick Installation Guide Edition 7.1, February 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Serial Communication Converters & Adapters Instruction Manual

Serial Communication Converters & Adapters Instruction Manual Serial Communication Converters & Adapters Instruction Manual RS-232 to RS-422/485 Converter Isolated RS-232 to RS-422/485 Converter USB to RS-232 Converter USB to RS-422/485 Converter Isolated USB to

More information

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA SELECTION AND APPLICATIONS OF PROGRAMMABLE LOGIC CONTROLLERS UNIT 25 - NQF LEVEL 3

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA SELECTION AND APPLICATIONS OF PROGRAMMABLE LOGIC CONTROLLERS UNIT 25 - NQF LEVEL 3 EDEXCEL NATIONAL CERTIFICATE/DIPLOMA SELECTION AND APPLICATIONS OF PROGRAMMABLE LOGIC CONTROLLERS UNIT 25 - NQF LEVEL 3 OUTCOME 4 - COMMUNICATION MEDIUM CONTENT Understand data communications media and

More information

Code Dynamics, Inc. Port Splitter

Code Dynamics, Inc. Port Splitter Code Dynamics, Inc. Port Splitter Thank you for purchasing the Port Splitter. With this product, you can utilize a single Andover port for both the modem and PC connections. This device connects to the

More information

Cat.8 Shielded Keystone Jack Description

Cat.8 Shielded Keystone Jack Description Description RiT s CAT8 Shielded Keystone Jacks are cost-effective building blocks for your cabling system. Meticulously engineered to deliver exceptional performance while streamlining installations. Phosphor

More information

Home Automation Systems Installation Guide for FFI Actuator & Control Projects

Home Automation Systems Installation Guide for FFI Actuator & Control Projects Home Automation Systems Installation Guide for FFI Actuator & Control Projects This installation guide is for home automation systems such as Crestron, Lutron and others which communicate with FFI controllers

More information

Unleashing the Power of DCC

Unleashing the Power of DCC Command Station LZ100 1 Unleashing the Power of DCC LZ100 Command Station Operations Manual Version 3.2 art. no. 20101 revised February 2001 Version 3.2 2 Command Station LZ100 Getting started To get started

More information

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Hypercable injecteur HPOE -  Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail : Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

More information

EnerSure Installation Guide

EnerSure Installation Guide EnerSure Installation Guide Danger!!! The electrical components of this system may contain voltage and /or amperage sufficient to injure or kill. Installation is only to be performed by a licensed, bonded

More information

PRIMUX CAT5 KVM System Quick Start Guide

PRIMUX CAT5 KVM System Quick Start Guide PRIMUX Series PRIMUX CAT5 KVM System Quick Start Guide What's in the Box (Host Adapter sold separately) NTI PRIMUX-UZR User Station 120VAC or 240VAC @ 50 or 60Hz, 5VDC/2A AC Adapter Line cord, country

More information

Modular Connectors 75

Modular Connectors 75 75 Plug/Jack Compliant to Enhanced Category 5 standards Connector type Size Series Name Page plug connectors compliant to enhanced category 5 standards 8 TM21P 77 jack connectors for high-speed LAN transmission

More information

AMP NETCONNECT EtherSeal System Bringing Ethernet and Structured Cabling to Non-Office Environments.

AMP NETCONNECT EtherSeal System Bringing Ethernet and Structured Cabling to Non-Office Environments. EtherSeal System Bringing Ethernet and Structured Cabling to Non-Office Environments. From the factory floor to the hospital room, Ethernet is the network type of choice. More and more TCP/IP applications

More information

MODEL 8000MP LEVEL SENSOR

MODEL 8000MP LEVEL SENSOR 1 MODEL 8000MP LEVEL SENSOR INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE VISIT OUR WEBSITE SIGMACONTROLS.COM 2 SERIES 8000MP LEVEL SENSOR 1. DESCRIPTION The Model 8000MP Submersible Level Sensor

More information

ez80190 Development Kit Quick Start Guide

ez80190 Development Kit Quick Start Guide Introduction Follow this guide to install and begin using your new ez80190 Development Kit from ZiLOG. The setup procedure guides the user through: Software installation and online registration Hardware

More information

Domain 3000 Back Panel

Domain 3000 Back Panel Domain 3000 Back Panel The Domain 3000 has 25 I/O ports plus a connector for an external power supply (included) and an LED to indicate that the power is on. Typically, it is placed on a shelf or equipment

More information

DOLPHIN PLUS. Instrument configuration software OLPHIN PLUS

DOLPHIN PLUS. Instrument configuration software OLPHIN PLUS DOLPHIN PLUS Instrument configuration software OLPHIN PLUS Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected

More information

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VS-808TP 8x8 Twisted Pair Matrix Switcher. P/N: Rev 1

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VS-808TP 8x8 Twisted Pair Matrix Switcher. P/N: Rev 1 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VS-808TP 8x8 Twisted Pair Matrix Switcher P/N: 2900-300147 Rev 1 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Using

More information

Cable and Port Specifications

Cable and Port Specifications Send documentation comments to mdsfeedback-doc@cisco.com APPENDIXC This appendix includes the cables and connectors used with the Cisco MDS 9100 Series Fixed Configuration Fabric Switch, and it includes

More information

T-Monitor E-Monitor TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

T-Monitor E-Monitor TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5 T-Monitor E-Monitor TABLE OF CONTENTS SECTION - DESCRIPTION... SECTION - SPECIFICATIONS...3 SECTION 3 - INSTALLATION... SECTION - FRONT PANEL INDICATORS...7 SECTION - INTERFACE SIGNALS AND CABLES...8 SECTION

More information

VGA Extender LR. EXT-VGA-141LR User Manual.

VGA Extender LR. EXT-VGA-141LR User Manual. VGA Extender LR EXT-VGA-141LR User Manual www.gefen.com Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday thru Friday. Write

More information

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP AX3000 Platine Terminal Ethernet TCP/IP Model 80WMS Installation Guide January 2012 - Ref: I80ME0922-2 Model AX3000/M80M Type EA The reproduction of this material, in part or whole, is strictly prohibited.

More information

Management Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P. Quick Installation Guide

Management Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P. Quick Installation Guide Management Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5 4. Logon to the Console...

More information

Hardware User s Manual. Digital Video Motion Detector DVMD1-X

Hardware User s Manual. Digital Video Motion Detector DVMD1-X Hardware User s Manual Digital Video Motion Detector DVMD1-X Version 010 Revision A July, 2004 2395 Kenwood Drive Boulder, CO 80303 (303) 543-0440 TECHNICAL SPECIFICATIONS VENDOR Radiant Inc. http://www.dvmd.com

More information

RC-SV Configuration Guide Revision 3

RC-SV Configuration Guide Revision 3 Kramer Electronics, Ltd. RC-SV Configuration Guide Revision 3 Software Version 2.1.2.32 Intended for Kramer Technical Personnel or external System Integrators. To check that you have the latest version,

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

RSB RS-232 Serial Booster

RSB RS-232 Serial Booster RSB RS-232 Serial Booster Users Guide Revision 1.01 B y R y a n S h e l d o n Copyright 1996, 1997, 1998, 1999, 2000, National Control Devices Disclaimer: NCD will not be responsible for any personal injury

More information

H-UC232S USB Serial Converter

H-UC232S USB Serial Converter H-UC232S USB Serial Converter FCC Warning This equipment has been tested and found to comply with the regulations for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed

More information

Installation and Configuration Guide

Installation and Configuration Guide Installation and Configuration Guide Trademark Notices Comtrol, NS-Link, and DeviceMaster are trademarks of Comtrol Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation.

More information

Smart CAT5 Switch 16 IP Installation Guide

Smart CAT5 Switch 16 IP Installation Guide Smart CAT5 Switch 16 IP Installation Guide International HQ Jerusalem, Israel Tel: + 972 2 535 9666 minicom@minicom.com North American HQ Linden, New Jersey Tel: + 1 908 4862100 info.usa@minicom.com European

More information

DAQ-System for DynoWare

DAQ-System for DynoWare Electronics & Software DAQ-System for DynoWare 5697A... Data Acquisition System for Force Measurement Data acquisition system for interfacing and controlling charge amplifiers and signal conditioners in

More information

Kramer Electronics, Ltd.

Kramer Electronics, Ltd. Kramer Electronics, Ltd. Preliminary USER MANUAL Model: FC-50 RS-232 Range Extender Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 3.1 About the Power Connect Feature

More information

RC-SV Configuration Guide (Rev 4)

RC-SV Configuration Guide (Rev 4) Kramer Electronics, Ltd. RC-SV Configuration Guide (Rev 4) Software Version 2.1.2.69 Intended for Kramer Technical Personnel or external System Integrators. To check that you have the latest version, go

More information

Modern Ethernet. Chapter 6

Modern Ethernet. Chapter 6 Modern Ethernet Chapter 6 Contents Define the characteristics, cabling, and connectors used in 10BaseT and 10BaseFL Explain how to connect multiple Ethernet segments Define the characteristics, cabling,

More information

SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with NOVA.16 (SK-MRCP) 16-Door Panel

SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with NOVA.16 (SK-MRCP) 16-Door Panel SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with (SK-MRCP) -Door Panel WITH RS- GATEWAY CONNECTED DIRECTLY TO A PC RS- GATEWAY POWER: EIGHT (8) SMART READERS EVENLY SPACED UP TO 000

More information

August DPX2213 VoIP Cable Modem User's Guide

August DPX2213 VoIP Cable Modem User's Guide August 2006 DPX2213 VoIP Cable Modem User's Guide Introduction In This Document What's In the Carton?... 5 Front Panel Description... 6 Back Panel Description... 8 Where Is the Best Location for My Cable

More information

HDMI Extender over Single CAT5/6 with IR/ RS-232 & Auto EDID Quick Installation Guide

HDMI Extender over Single CAT5/6 with IR/ RS-232 & Auto EDID Quick Installation Guide Introduction HDMI Extender over Single CAT5/6 with IR/ RS-232 & Auto EDID Quick Installation Guide The HDMI Extender over Single CAT5/6 with IR/RS-232 & Audio EDID supports is equipped with bi-directional

More information

Modular 8-Port Mid-span Power over Ethernet Injector

Modular 8-Port Mid-span Power over Ethernet Injector Modular 8-Port Mid-span Power over Ethernet Injector KPOE-800-1P KPOE-800-2P Installation Guide DOC.090201 1 (C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

FieldServer X-25 Start-Up Guide

FieldServer X-25 Start-Up Guide Sierra Monitor Company FieldServer X-25 Start-Up Guide APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after April 2013 Kernel Version: 6.10 Document Revision: 0 FieldServer FS-X25 Start-Up

More information

Artistic Licence. Net-Lynx I/P. User Guide. Net-Lynx I/P User Guide. Version 1-5

Artistic Licence. Net-Lynx I/P. User Guide. Net-Lynx I/P User Guide. Version 1-5 Artistic Licence Net-Lynx I/P User Guide Version 1-5 Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be

More information

modunet292: novanet-ethernet interface

modunet292: novanet-ethernet interface SAUTER EY-modulo 2 PDS 96.015 en Product Data Sheet EY-BU292 : - interface How energy efficiency is improved SAUTER EY-modulo 2 integrated into familiar IP technology Areas of application Parameterisation

More information

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3 INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: June, 2016 Version: 1.3 2 What s in the Box 2 Screws & Anchors 2 Screwdriver 4 Diode CONTENT Contents What s in the Box...2 Optional accessories...4

More information

Quick Start Installation Guide

Quick Start Installation Guide istar Pro Quick Start Installation Guide Version B0 Part Number UM-069 January 2005 OVERVIEW This guide defines all of the commonly used connection methods to the istar Pro. It outlines how to wire readers

More information

with its cables, connectors, Switches, Hubs and topologies

with its cables, connectors, Switches, Hubs and topologies Introduction to LAN www.mycsvtunotes.in with its cables, connectors, Switches, Hubs and topologies LAN Small interconnected computers or workstations within a building or small area up to 10 Kms. Small

More information

VGA Extender LR. EXT-VGA-141LR User Manual.

VGA Extender LR. EXT-VGA-141LR User Manual. VGA Extender LR EXT-VGA-141LR User Manual www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday

More information

Lecture (03) Ethernet Protocol & Network Hardware Components

Lecture (03) Ethernet Protocol & Network Hardware Components Lecture (03) Ethernet Protocol & Network Hardware Components Dr. Ahmed M. ElShafee 1 Agenda Ethernet Protocol/ and cable types Network interface card Network nodes Servers Clients Storage area network

More information

CO-485USB USB to RS-485 CONVERTER TECHNICAL REFERENCE

CO-485USB USB to RS-485 CONVERTER TECHNICAL REFERENCE TABLE OF CONTENTS CO-485USB USB to CONVERTER TECHNICAL REFERENCE Specifications, Description and Technical Support... page 1 Connection Diagram... page 2 Set-Up & Testing... page 3 & 4 Power Supply Shunts...

More information

Advanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units

Advanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units GE Energy Industrial Solutions GEH-704 Installation Instructions Advanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units

More information

Classic Brain Boards. Classic Brain Boards. Features. Description. Networking. Part Numbers

Classic Brain Boards. Classic Brain Boards. Features. Description. Networking. Part Numbers B2 Analog Brain Board Features Intelligent digital processors. Serial data link operates at selectable baud rates from 300 baud to 38.4 Kbaud Optomux units can be configured for either multidrop or repeat

More information