1 Open System Architecture Selecting the Right Cable and Connectivity for Your Application Kenneth Cornelison Industry Consultant Wire and Cable Technology Engineering Resources
2 Key Discussion Points TIA system structure overview Component Ratings rated and verified Interoperability testing across different connectivity solutions Survey to evaluate performance across connectivity solutions Information valuable for system warranty content and scope Manufacturer system warranties - Key elements and attributes Summary
3 TIA and Standards Structure TIA Family of documents ranging from system to components Component, system, installation guidance and requirements IEC has similar set of documents for cables and structured cabling systems BICSI accreditation, ti standards d and document structure t
4 TIA Standards Overview Common standards - TIA 568; 569; 606; etc. Cover building, installation, administration Premise Standards - TIA 570; 758; 942; etc. Premises standards - Infrastructure Component Standards - TIA 568 Copper and Fiber
5 Rapidly Growing Technical Requirements TIA Cabling Standards Category 3: Cables and outlets up to 16 MHz. Category 5e: Cables and outlets up to 100 MHz with enhanced characteristics over cat 5. Category 6 : Cables and outlets up to 250 MHz. Category 6a : Cables and outlets up to 500MHz for 10Gbit Ethernet operation. ISO/IEC Cabling Classes - Similar structure to the TIA Class C Up to 16 MHz Category 3 Class D Up to 100 MHz Category 5e Class E Up to 250 MHz Category 6 Class Ea Up to 500MHz Category 6a (amend 1&2) Class F Up to 600 MHz Class Fa Up to 1000MHz (amend 1&2) NEXTGEN Category 8 Up to 2000MHz over 30m New Proposed Applications 2.5Gb, 5Gb and others
6 A Key Why to Standards Many reasons why for standards Common system and component characteristics facilitate system cost and ease of installation Interoperability for components and systems is one of the key reasons A basic premise of the Structured Cable System Encourages mass production, economies of scale, and broader applications Facilitates implementation of open system warranties Customer confidence Consistent and reliable performance
7 Compliant vs Verified Component Verification Third party vs internal testing and qualification Choosing components that t are independently d verified Warranties rely on verified components to assure performance
8 Structured Cabling Warranties and Performance Warranties are enhanced (and even enabled) by the standards and accreditation structure of TIA, IEC, BICSI and other organizations Warranty success depends on both the hardware performance and the installation skills of the installer Warranties available through certified installers An important result of having standards is the confidence in the market provided by standard components and installer skills
9 Project to Assess Link Performance Project initiated from a cable manufacturer s need to survey performance with recognized connectivity manufacturers Selection of widely used cable types and connectivity solutions Testing in Permanent link configuration
10 Testing Across Connectivity Manufacturers Purpose of Testing Cable manufacturers offer an open warranty on installed systems A need for an overall assessment of link performance for a range of approved connectivity solutions A way to confirm that the connectivity approval lists are appropriate for warranty coverage A snapshot verification of the open system architecture performance
11 90 Length of Category cable Cable test Establishing a Baseline Cable without connectors tested with automatic Network Analyzer (VNA) based test hardware as a baseline Key electrical parameters captured, including balance performance Good margin to both Cable and Permanent Link requirements
12 Conditions for Link Testing Permanent Link tested at 90m length Field tester used for testing All frequency sweep data exported and analyzed Performance margin and comparison to cable measurements summarized Permanent Link with two connections Terminal Outlet (TO) and Cross-connect (C1) Optional consolidation point (CP) not included
13 Testing Outline Multiple manufacturers of connectivity 6 for Category 6 UTP 6 for Category 6A UTP 3 for Category 6A FUTP Multiple tests for each combination Same length of cable used for all tests within Category family Cables listed and verified to TIA 568C.2 Limited number of operators following good practices Laboratory test environment
14 Category 6 Cable Baseline Results - NEXT (tested to 500MHz)
15 Category 6 RL and TCL Baseline Results (tested to 500MHz)
16 Cable vs Cable + Connector Electrical performance curves do change appearance when adding connectivity Split Pair Effects Connectivity design and circuitry Interaction with cable design
17 Cable and Cable + Connector A to Permanent Link Typical occurrence from all connectivity suppliers of an outlier NEXT response Overall, NEXT was the most variable across multiple connectors of the same supplier
18 Cat 6 Connector A Test Result Examples
19 Cat 6 Cable and Connector A Return Loss
20 Cat 6 Cable and Connector A TCL
21 NEXT Margin Data Overview Key Takeaway More variability than expected Main Remote
22 Return Loss Margin Data Example Consistency within a connector type
23 TCL Margin Data Example Consistency within a connector type
24 NEXT Permanent Link Performance Variability All connector types had variations from test to test But not all connector types had the same variation characteristics No one connector stood out across all combinations
25 Cat 6 NEXT Margin Variation Across 6 different manufacturers
26 Cat 6 NEXT Margin Variation Across 6 different manufacturers
27 Cat 6 NEXT Margin Variation Across 6 different manufacturers
28 Category 6 Testing Summary Even with the same cable from test to test, NEXT had the most variability from test to test Other parameters, such as TCL and RL were more consistent All tests met Permanent link requirements with margin Variability did not seem to differ whether at main or remote end of the cable
29 Category 6A UTP and FUTP Testing The same test procedure was followed for Category 6A components 90m baseline test on cable 90m links tested in a 2 connector arrangement Consistent operator and termination techniques
30 6A Permanent Link NEXT Margins Connector A
31 Cat 6A UTP More consistent NEXT, but not always the same
32 Category 6A UTP Testing Summary Overall, more NEXT consistency between tests, and between connectivity solutions than with Category 6 Consistency in the other electrical parameters (RL, TCL) among the different connectivity solutions Key attribute for 6A UTP links is Alien crosstalk, which may lead to more consistent results
33 Category 6A FUTP NEXT Summary
34 Category 6A FUTP FUTP data similar to the Category 6 UTP data Variable NEXT results from test to test Consistent data for RL, IL, TCL, and other tests
35 Permanent Link Data Summary All connectivity combinations pass the industry permanent link standards Good electrical performance allows the user the option of selecting connectivity across other key parameters with assured performance Ease of installation; cost; availability; manufacturer support Data supports warranties from cable maker across a range of connectivity options
36 Key Warranty System Attributes Requires industry standard component compliance and verification Provides guaranteed performance levels for installed system Supplier resources system support, technology, capabilities Establishes chain of communication for system performance, maintenance Establishes responsible parties for problem resolution Establishes a set of components and systems with reliable performance 3 rd party location for system test data retention Warranted channels can support multiple and new applications
37 Access to product specific information Training Resources Scope of covered products Hands-on opportunities
38 Open and Closed System Warranties Advantages of an open system warranty Choosing components to suit installation needs Flexibility for installers, system integrators Backed by Industry standard specifications and structure Closed solutions have advantages, but some drawbacks Some closed solutions are a specific example of an open solution available elsewhere There are fewer closed solutions from one manufacturer than closed solutions that use at least two different manufacturers Closed solutions that are multi-company can and do come and go over time Limited product/performance options Warranty restrictions out of network products risk the entire project warranty
39 Accredited Installations Move, add, change documentation?
40 Read the warranty first Does it have Warranty Fine Print Limited time (even a few days) to notify warranty provider of problems? Ability to transfer warranties? Void if components are more than a few months old? A choice of components to best meet the user overall needs Provider training resources providing BICSI credits? A milestone date when the warranty starts? Availability of support resources Installer, component manufacturers, etc Coverage for permanent link portion or end to end?
41 Summary Survey test results confirm performance meeting requirements There are differences among the components in the testing, but all meet requirements Variability from test to test observed even with relatively controlled testing environment Variability with both Category 6 and 6A links All components tested from a 3 rd party verified supplier Warranty decisions Knowledge of warranty coverage, details, and requirements Limitations within warranty for timing of key events, warranty scope, etc Use of components with 3 rd party verification services Flexibility in choosing components and installers
42 Thank You
CERTIFICATION PLUS SM
CERTIFICATION PLUS SM SYSTEM WARRANTY PROGRAM Panduit Warranty Guide PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction & Installation
More informationPANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY
PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents
More informationPANGEN SYSTEM WARRANTY. Warranty Guide
PANGEN SYSTEM WARRANTY Warranty Guide C2-10270 PANGEN SYSTEMWARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction &
More informationISO/IEC TR Guidance on 40GBASE-T T Cabling
1 ISO/IEC TR 11801-99 99-1 Guidance on 40GBASE-T T Cabling - a tutorial - Alan Flatman Principal Consultant LAN Technologies Email: a_flatman@tiscali.co.uk 2 Content 1. introduction to ISO/IEC SC25 WG3
More informationCategory 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope
Category 8 paves the way for IEEE 40GBASE-T David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope Agenda Market need for 40 G over balanced twisted pair cabling Standards ISO/IEC 11801-99-1
More informationEnterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India
Enterprise Network Test Strategies for Network Availability and Performance A Sitaramaiah Director Fluke Networks India 1 Why is Enterprise Network Testing becoming increasingly important? IT is increasingly
More informationDatasheet: DSX CableAnalyzer Series
Datasheet: DSX CableAnalyzer Series Datasheet: DSX CableAnalyzer Series The DSX CableAnalyzer Series is the copper certification solution of the Versiv cabling certification product family. The DSX Series
More informationCertification for 10G copper cabling
Certification for 10G copper cabling Presented by Eric Lie, Sales Manager 1 Introduction This presentation is intended to provide an overview of the 10GBASE-T requirements for cabling The applicable standards
More informationISO/IEC SC25 WG3. Who are they & what can they do for 802.3cg? Alan Flatman. Principal Consultant LAN Technologies.
1 ISO/IEC SC25 WG3 Who are they & what can they do for 802.3cg? Alan Flatman Principal Consultant LAN Technologies Email: a_flatman@tiscali.co.uk 2 Who are ISO/IEC SC25 WG3? Ø International systems group
More informationCopper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only
1 Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only Gautier Humbert, RCDD Standards Coordinator Digital Infrastructures Legrand District Chair Mainland Europe BICSI 2 Agenda
More informationThe High Cost of a Low-Cost Cable Certification Tester
The High Cost of a Low-Cost Cable Certification Tester Our thanks to Fluke Networks for allowing us to reprint the following article. How much does it cost? That is typically the first question a cabling
More informationPerformance specification for the Fluke DSP Fluke Corporation
Performance specification for the Fluke Fluke Corporation 1. Summary This document contains the performance specifications in terms of requirements per draft TIA and IEC specifications. Since requirements
More informationCopper Cabling Standards
Copper Cabling Standards White paper White Paper Copper Cabling Standards v2.0 EN 1 Introduction Standard specifications are the foundation upon which most cabling and networking projects are built. Professionals
More informationLANmark-6 10G LANmark-6 A
Field-testing procedure of LANmark-6 10G LANmark-6 A Cabling System Technical Paper Nexans Cabling Solutions March 2006 - Revision 1.1 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction
More informationSingle-pair cabling channel specifications
Single-pair cabling channel specifications IEEE P802.3cg 10SPE Task Force October 25, 2017 Dave Hess, CORD DATA 10/25/2017 hess_10spe_01_1025 1 Overview JMTG organization and scope JMTG projects related
More informationField-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4
Field-testing procedure of LANmark-6 10G Cabling System Technical Paper Nexans Cabling Solutions June 2007 - Revision 1.4 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent
More informationWhite paper. Field Testing of Direct Attach Modified Permanent Links. occfiber.com
The dramatic growth of high-bandwidth wireless access points and other IP-enabled devices, such as surveillance cameras and building automation equipment has resulted in the practice of installing direct
More informationIndustry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"
Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print" Gautier Humbert, RCDD Standards Coordinator Legrand Digital Infrastructures Gautier Humbert, RCDD BICSI District Chair Mainland
More informationThe Impact of Internet of Things (IoT) on Cable Certification
The Impact of Internet of Things (IoT) on Cable Certification Simon Harrison General Manager Softing Singapore Pte Ltd November 2017 Agenda Review of traditional structured cabling configurations Special
More informationPsiber Data WireXpert P R O F E S S I O N A L N E T W O R K T E S T I N G & P R O T O C O L A N A L Y S I S
Psiber Data WireXpert Agenda Psiber Data WireXpert Introduction Company Presentation Why Cable Certification? Universal Structured Cabling or The Network Standards The WireXpert Page 2 Psiber Data Company
More informationANSI/TIA-568-C Cat 6 Field Test Specifications
This document has been prepared to aid consultants or engineers in developing contractual specifications covering the certification of Category 6 Permanent Links. It is offered as a general guide. Suitability
More informationDesign Guidelines. LANmark-6A Cabling System. January 2015 Revision 2.0. Nexans LANmark-6A Design Guidelines Ver January Page 1
Design Guidelines LANmark-6A Cabling System January 2015 Revision 2.0 Nexans LANmark-6A Design Guidelines Ver 2.0 - January 2015 - Page 1 This document is intended to provide general guidance on LAN cabling
More informationConformity Assessment Schemes and Interoperability Testing (1) Keith Mainwaring ITU Telecommunication Standardization Bureau (TSB) Consultant
Conformity Assessment Schemes and Interoperability Testing (1) Keith Mainwaring ITU Standardization Bureau (TSB) Consultant Moscow, 9-11 november 2011 Contents The benefits of conformity assessment Conformity
More informationANSI/TIA-568-C Cat 6A Field Test Specifications
This document has been prepared to aid consultants or engineers in developing contractual specifications covering the certification of Category 6A Permanent Links. It is offered as a general guide. Suitability
More informationDr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant
Is Cable Balancing Efficient i Enough for EMI Mitigation in Data Centers? Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant What are You going to Learn? What are the potential sources
More information[0.057] 5.8 [0.23]
Product Specification 7 March 13 Rev A1 SL Series Jacks, Category 6 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, Category 6 SL Jacks used
More informationEthernet and PoE Operation Over Single Pair Twisted-Pair Copper Cabling (SPE) Chris DiMinico AEM Technical Sales Test and Measurement
Ethernet and PoE Operation Over Single Pair Twisted-Pair Copper Cabling (SPE) Chris DiMinico AEM Technical Sales Test and Measurement Overview SPE is poised to enable a new class of low power devices that
More informationCable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS.
Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications Broadband High-Speed LAN Voice Robert Y. Faber Jr., RCDD/NTS Minimum Port Recommendations TIA/EIA-568-B.1 2 outlets
More informationField-testing procedure. LANmark-6
Field-testing procedure LANmark-6 Technical Paper Nexans Cabling Solutions September 2006 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent link testing vs. Channel
More informationMutual Recognition Agreement/Arrangement: General Introduction, Framework and Benefits
Conformity and Interoperability Training for SADC Region on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance Mutual Recognition Agreement/Arrangement: General
More informationS. Scholz / K. Meyer / J.E. Nielsen / Harald Drück/J.Fernández/E.Prado/L.Nelson Page 1 of 7
Global Solar Certification Network Working Rules Annex A. Requirements for Certification Bodies and their subcontracted laboratories, inspection bodies and inspectors Date: 2017/03/07 Document number:
More informationJoint ITU-UNIDO Forum on Sustainable Conformity Assessment for Asia-Pacific Region (Yangon City, Republic of Union of Myanmar November 2013)
Joint ITU-UNIDO Forum on Sustainable Conformity Assessment for Asia-Pacific Region (Yangon City, Republic of Union of Myanmar 25-27 November 2013) Mark Amos Business Manager, IECEx Secretariat, IEC mark.amos@iecex.com
More informationUSDA ISO Guide 65 Program Accreditation for Certification Bodies
Page 1 of 6 USDA ISO Guide 65 Program Accreditation for Certification Bodies 1 Purpose This document provides the requirements to be met in designing a USDA ISO Guide 65 Program. It also provides the requirements
More informationHow new testing standards affect you Singapore, Nov 2009
How new testing standards affect you Singapore, Nov 2009 Adrian Young Sr. Customer Support Engineer In this presentation, we will cover How ANSI/TIA-568-C.2 has consolidated all the different test plugs
More information[0.057] 5.8 [0.23]
Product Specification 7 June 13 Rev B SL Series Jacks, Category 6 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, Category 6 SL Jacks used
More informationAppendix 1 to the R&Mfreenet Warranty Program
Appendix 1 to the R&Mfreenet Warranty Program 1 R&M Certification Process The R&Mfreenet certification process is three pillars: a) Adherence to applicable standards, both for products and installations;
More informationMeeting updated ISO/IEC Your professional partner of structured cabling system
Meeting updated ISO/IEC11801 Premium Line Systems Group Premium Line Systems GmbH, Based in Germany, it is the worldwide headquarter 25 Years experience in Cabling and Networking products End-to-End comprehensive
More informationO p e A n rchitecture
Open Architecture What is Open Architecture? If you are installing a network infrastructure utilizing fiber optic, Category 5e, 6 or 6A components, there is a sizable selection of well known products available.
More informationThe International Laboratory Accreditation Cooperation (ILAC) & The International Accreditation Forum (IAF)
The International Laboratory Accreditation Cooperation (ILAC) & The International Accreditation Forum (IAF) Perspectives on ILAC & IAF Multilateral Mutual Recognition Arrangements Peter Unger, ILAC Chair
More informationWhite Paper: Installing Data Networks Using LinkWare Live SaaS
White Paper: Installing Data Networks Using LinkWare Live SaaS White Paper: Installing Data Networks Using LinkWare Live SaaS Software as a Service (SaaS) continues to grow in popularity across a wide
More informationTelecommunications Equipment Certification Scheme FEBRUARY 2017
Telecommunications Equipment Certification Scheme FEBRUARY 2017 Canberra Red Building Benjamin Offices Chan Street Belconnen ACT PO Box 78 Belconnen ACT 2616 T +61 2 6219 5555 F +61 2 6219 5353 Melbourne
More informationNGBASE-T Cabling Requirements
NGBASE-T Cabling Requirements Dr. T. C. Tan, DMTS, CommScope Labs B.Sc (Eng), DIC, PhD, CEng, FIET White paper www.commscope.com Contents Contents Contents 2 1.0 Introduction 3 2.0 IEEE 802.3 NGBASE-T
More informationPlumbing Product Certification WaterMark Level 2
NCSI Recognition Booklet Addendum Plumbing Product Certification WaterMark Level 2 1. General In Australia most of the plumbing and drainage products and materials are required to be certified under the
More informationPhysical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks
Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks Agenda New ISO/IEC 11801 Standard New Fibre standards and encoding methods Higher speeds,
More informationANSI/TIA/EIA-568-B Cabling Standard
73 ANSI/TIA/EIA-568-B Cabling Standard In the mid-1980s, consumers, contractors, vendors, and manufacturers became concerned about the lack of specifications relating to telecommunications cabling. Before
More informationMORE ETHERNET ON THE HORIZON WHO NEEDS 2.5G AND 5G ETHERNET? Krzysztof Ojdana, Product Manager WHITE PAPER. Molex Connected Enterprise Solutions
MORE ETHERNET ON THE HORIZON WHO NEEDS 2.5G AND 5G ETHERNET? Krzysztof Ojdana, Product Manager WHITE PAPER Molex Connected Enterprise Solutions EXECUTIVE SUMMARY Ethernet seems to be one of the fastest
More informationAnticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards
Anticipating Cat 8 Agenda Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards What is Cat 8? Next Generation Copper Cabling 25G and 40G data rates over twisted pair copper
More informationLeveraging the Structured Cabling System for Security Applications. Mark Dearing, RCDD Leviton Network Solutions
Leveraging the Structured Cabling System for Security Applications Mark Dearing, RCDD Leviton Network Solutions Trends - Cable Category Mix Source: Leviton projections based on market growth rates Over
More informationTraining Offer. Catalogue
Training Offer Catalogue docnr. 3.0 rev.date: 04 August 2008 2/13 Introduction, "The transmission quality of a cabling installation depends on the cabling system used, as well as the installation itself."
More informationIntroduction. Standards
Introduction LAN cable certifiers have been the go-to method of testing twisted pair cabling for nearly a quarter century, since the advent of 10Base-T on Class C/category 3 cabling to 10 MHz. This article
More informationThe Value of ANSI Accreditation. Top 10 Advantages. of accredited third-party conformity assessment
The Value of ANSI Accreditation Top 10 Advantages of accredited third-party conformity assessment The American National Standards Institute (ANSI) offers highly recognized accreditation programs globally
More informationHistory of Standards
History of Standards From 10Mbps to 100Gbps Ethernet 12 th May 2014 Gautier Humbert, RCDD Business Development Manager Legrand East and Central Europe Agenda 1- Current standards and their structures
More information40G BASE-T Cabling Infrastructure. Allan Nielsen Standards Manager
40G BASE-T Cabling Infrastructure Allan Nielsen Standards Manager 40GBASE-T Transmission with bi-directional 4x10G nearby cable Switch 40GBASE-T signal spectrum up to 1.600 MHz Alien Crosstalk (AXT) Shield
More informationFrequently Asked Questions (FAQs) Siemon 10G ip Solutions
Frequently Asked Questions (FAQs) Siemon 10G ip Solutions The world of enterprise cabling is evolving rapidly. Emerging, high-bandwidth services and the adoption of higher speed Ethernet standards, like
More information"IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI TRASMISSIVI FINO A 250 MHZ"
"IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI TRASMISSIVI FINO A 250 MHZ" Gli standard per la categoria 6 e i nuovi strumenti di misura maurizio.malinconi@flukenetworks.com
More informationIEC Quality Assessment System for Electronic Components (IECQ System)
IECQ 03-4 Edition 2.0 2012-09 IECQ PUBLICATION IEC Quality Assessment System for Electronic Components (IECQ System) Rules of Procedure Part 4: IECQ ECMP Scheme Avionics Assessment Program Requirements
More informationCopper Certification Testing Best Practices Pocket Guide
Copper Certification Testing Best Practices Pocket Guide Cabling certification is a best practice of world class installers because it shows the true quality of the installation and reduces the risk of
More informationACCREDITATION COMMISSION FOR CONFORMITY ASSESSMENT BODIES
ACCREDITATION COMMISSION FOR CONFORMITY ASSESSMENT BODIES ACCREDITATION SCHEME MANUAL Document Title: Document Number: Various Accreditation Schemes ACCAB-ASM-7.0 CONTROLLED COPY Revision Number Revision
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO/IEC 15018 First edition 2004-06 Information technology Generic cabling for homes ISO/IEC 2004 All rights reserved. Unless otherwise specified, no part of this publication may
More informationThe Impact of Internet of Things on Cable Certification
The Impact of Internet of Things on Cable Certification Softing IT Networks ---Philippe PATINOTE --- Agenda Short introduction Softing IT Networks Brief review on traditional office cabling configurations
More informationIEEE Conformity Assessment Program (ICAP) June12, 2013
IEEE Conformity Assessment Program (ICAP) June12, 2013 Understanding Conformity Assessment Understanding Conformity Assessment What is Conformity Assessment? Conformity Assessment is defined as the process
More informationDemonstrate and apply knowledge of computer networking infrastructure principles
Demonstrate and apply knowledge of computer networking infrastructure principles 22713 version 1 Page 1 of 5 Level 4 Credits 15 Purpose This unit standard covers the necessary introductory skills required
More informationQualified Partner Programme QPP. Cat.6 Channel Meassurement Issues Felice Guarna
Qualified Partner Programme QPP Cat.6 Channel Meassurement Issues Felice Guarna Agenda Channel and link definitions Why measure a channel? Patch cord affects on link performance The challenge of channel
More informationCommon Mistakes Made in Certification Specifications and Testing. Jim Davis Regional Marketing Engineer Fluke Networks
Common Mistakes Made in Certification Specifications and Testing Jim Davis Regional Marketing Engineer Fluke Networks Common Mistake #1 Failing to specify a Permanent Link test #1 Permanent Link or Channel?
More informationMosaic TM LCS2 Cat. 6 RJ 45 socket
870 LIMOGES Cedex Telephone : + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Mosaic TM LCS2 Cat. 6 Page 765 61 765 44 765 94 1. General characteristics...1 2. Presentation...2 3. Installation....2 4.
More informationSECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION
SECTION 17045 TELECOMMUNICATIONS TESTING AND DOCUMENTATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including Facilities Management Design and Construction
More informationStandards Update. by Paul Kish NORDX/CDT
Standards Update by Paul Kish NORDX/CDT Standards overview Category 5e cabling new transmission parameters patch cord return loss Category 6 cabling cable choices backwards compatibility Summary Outline
More informationMosaic TM LCS2 Cat. 6 RJ 45 socket
870 LIMOGES Cedex Telephone : + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Mosaic TM LCS2 Cat. 6 Page 765 61 765 44 765 94 1. General characteristics....1 2. Presentation...2 3. Installation...2 4.
More informationncompass High Performance Cabling Systems connect. completely.
ncompass TM High Performance Cabling Systems Sup eri or Ess ex complete support. complete efficiency. complete reliability. connect. completely. complete flexibility. To overcome the challenges of an ever-changing
More informationApplication Note: Mode Conversion Testing Prevents Your Network from Hanging in the Balance
Application Note: Mode Conversion Testing Prevents Your Network from Hanging in the Balance Application Note: Mode Conversion Testing Prevents Your Network from Hanging in the Balance There is a reason
More informationPRIOR LEARNING ASSESSMENT AND RECOGNITION (PLAR)
PRIOR LEARNING ASSESSMENT AND RECOGNITION (PLAR) 1. INTRODUCTION 1.1 Purpose of the Guidelines These guidelines have been developed by TVETA to guide TVET Providers on how to: (i) Prepare, plan, and implement
More informationHazardous Locations. Product Certification Solutions
Hazardous Locations Product Certification Solutions 2 Designing and manufacturing products for hazardous locations is a complex environment to navigate, with many requirements for certification. To achieve
More informationSPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING
PART 1: GENERAL 1.01 SCOPE OF WORK A. The Designer and Contractor are responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable to the
More informationSouth African Forestry Assurance Scheme SAFAS 6:2018. Certification and Accreditation Procedures. Issue SAFAS Council SAFAS
South African Forestry Assurance Scheme SAFAS 6:2018 Issue 1 2018-05-22 SAFAS 346 Burger Street Pietermaritzburg South Africa Tel: +27 33 897 5000 1 Document name: Document number: SAFAS 6:2018 Approved
More information40 Gigabit over copper - Thorsten Punke Marketing Manager ANZ TE Connectivity
40 Gigabit over copper - 40GBase-T Thorsten Punke Marketing Manager ANZ TE Connectivity IEEE 802.3 Ethernet Update 40GBase-T The history The technical truth The technical history More speed equals to more
More informationStandardkonforme Absicherung mit Model-Based Design
Standardkonforme Absicherung mit Model-Based Design MATLAB EXPO 2014 Dr. Marc Segelken Principal Application Engineer 2014 The MathWorks, Inc. 1 Safety Standards for Embedded Systems IEC 61508 ISO 26262
More informationMutual Recognition Agreement/Arrangement: General Introduction, Framework and Benefits
Workshop for Caribbean countries to promote the development and implementation of Conformity Assessment programmes St. Augustine (Trinidad and Tobago) 2-4 December 2014 Mutual Recognition Agreement/Arrangement:
More informationJamey Calloway, RCDD Product Management Specialist Optical Cable Corporation
Testing and deployment of direct attach and the impact of category 8 Thursday, 10 August 2017, 3:50-4:40 P.M. Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation Overview Traditional
More informationDatasheet: DSX-5000 CableAnalyzer
Datasheet: DSX-5000 CableAnalyzer The DSX-5000 CableAnalyzer is the copper certification solution and is part of the Versiv cabling certification product family. The Versiv line also includes fiber OLTS
More informationWireScope 155 SCOPE. Agilent Wirescope 155 Specs Provided by The Performance Leader in Hand-Held Network Tools
Agilent Wirescope 155 Specs Provided by www.aaatesters.com WireScope 155 Tests installed cabling for compliance with TIA 568A Category 5 and ISO 11801 Class D specifications. Fully implements TIA TSB-67
More informationHANDBOOK OF CABLE TESTING
Testing and Measurement Technology Fault Analysis Documentation and Reporting HANDBOOK OF CABLE TESTING Wire pert Cable Certifier WX4500 Best-in-Class Certifier for today and tomorrow. CAT 8 Ready! CAT8
More informationTesting Network Infrastructure
Testing Network Infrastructure February 2016 Dan Payerle IDEAL Networks Network Infrastructure The infrastructure of a network can be summarized into two categories, passive cabling and active equipment.
More informationCERTIFICATION ISSUES IN AUTOMOTIVE SOFTWARE
CERTIFICATION ISSUES IN AUTOMOTIVE SOFTWARE Speaker: Mario Fusani Systems and Software Evaluation Centre ISTI CNR, Pisa, Italy mario.fusani@isti.cnr.it 1 CONTENTS Certification What is certification? Definitions
More informationCNAS-RC02. Rules for Sanctions against the Accreditation of Certification Bodies
CNAS-RC02 Rules for Sanctions against the Accreditation of Certification Bodies CNAS CNAS-RC02:2014 Page 1 of 7 Foreword This document is developed by CNAS. This document specifies rules for sanctions
More informationGet ready to overachieve.
Datasheet: DSX-5000 CableAnalyzer The DSX-5000 CableAnalyzer is the copper certification solution and is part of the Versiv cabling certification product family. The Versiv line also includes fiber OLTS
More informationCreate the ideal conditions for your network to grow.
Create the ideal conditions for your network to grow. Create the ideal conditions for your network to grow. SBC PremierSERV SM Network Integration and Managed Services. Flexible, end-to-end solutions
More informationBalanced single-pair cabling channel specifications
Balanced single-pair cabling channel specifications IEEE P802.3cg 10SPE Task Force July 9, 2018 Dave Hess, CORD DATA 07/09/2018 hess_3cg_01_0718 1 Overview This contribution reflects the views of the presenter
More informationDATA INTEGRITY (EMA AUGUST 2016)
Data integrity Data integrity enables good decision-making by pharmaceutical manufacturers and regulatory authorities.it is a fundamental requirement of the pharmaceutical quality system described in EU
More information10 GIGABIT ETHERNET. 10GBASE-T Physical Layer Interoperability Test Suite Version 1.0. Technical Document. Last Updated: October 3, :30 PM
. 10 GIGABIT ETHERNET 10GBASE-T Physical Layer Interoperability Test Suite Version 1.0 Technical Document Last Updated: October 3, 2008 2:30 PM 10 Gigabit Ethernet Consortium 121 Technology Drive, Suite
More informationHighlights: ISO/IEC SC25/WG3 Meeting Madrid: 27 Feb - 01 Mar Customer Premises Cabling -
1 ISO/IEC SC25/WG3 Meeting Madrid: 27 Feb - 01 Mar 2012 - Customer Premises Cabling - Highlights: 1. ISO/IEC 14763-2 Planning/Installation published 2. ISO/IEC 14763-3 OF Testing Ed.2 CD April 2012 3.
More informationTelecommunication Cabling Standards to address IoT and power delivery. 5 October
Telecommunication Cabling Standards to address IoT and power delivery 1 5 October 2018 www.vti.net.au In a nut shell Out for comment NOW AS/NZS 11801.1 (General requirements) AS 11801.2 (Office) AS 11801.3
More informationIT Governance ISO/IEC 27001:2013 ISMS Implementation. Service description. Protect Comply Thrive
IT Governance ISO/IEC 27001:2013 ISMS Implementation Service description Protect Comply Thrive 100% guaranteed ISO 27001 certification with the global experts With the IT Governance ISO 27001 Implementation
More informationProvided by
Provided by www.aaatesters.com Datasheet: DSX-5000 CableAnalyzer The DSX-5000 CableAnalyzer is the copper certification solution and is part of the Versiv cabling certification product family. The Versiv
More informationSpillemyndigheden s requirements for accredited testing organisations. Version of 1 July 2012
Version 1.3.0 of 1 July 2012 Contents 1 Introduction... 3 1.1 Authority... 3 1.2 Objective... 3 1.3 Target audience... 3 1.4 Version... 3 1.5 Enquiries... 3 2 Certification... 4 2.1 Framework for certification...
More informationISO/ IEC (ITSM) Certification Roadmap
ISO/ IEC 20000 (ITSM) Certification Roadmap Rasheed Adegoke June 2013 Outline About First Bank Motivations Definitions ITIL, ISO/IEC 20000 & DIFFERENCES ISO/ IEC 20000 Certification Roadmap First Bank
More informationAMP-TWIST* 6S Series SL Jack
Product Specification 108-93003 16/Mar/2011 Rev E AMP-TWIST* 6S Series SL Jack 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, AMP- TWIST*
More information10 GB Ethernet: Copper or Fiber? Choosing the Right Media for the Application
10 GB Ethernet: Copper or Fiber? Choosing the Right Media for the Application Outline Why 10 GB Ethernet? Current Standards Copper Choices Fiber Choices Comparison Summary Why 10 GB Ethernet? Aggregation
More informationCreate a website for a stakeholder using a dedicated web-authoring tool
Page 1 of 5 Create a website for a stakeholder using a dedicated web-authoring tool Level 3 Credits 5 Purpose People credited with this unit standard are able to: plan design a website for a stakeholder;
More informationACCREDITATION COMMISSION FOR CONFORMITY ASSESSMENT BODIES
ACCREDITATION COMMISSION FOR CONFORMITY ASSESSMENT BODIES ACCREDITATION SCHEME MANUAL Document Title: Document Number: Various Accreditation Schemes ACCAB-ASM-7.0 CONTROLLED COPY Revision Number Revision
More informationIMPLEMENTATION COURSE (MODULE 1) (ISO 9001:2008 AVAILABLE ON REQUEST)
ISO 9001:2015 IMPLEMENTATION COURSE (MODULE 1) (ISO 9001:2008 AVAILABLE ON REQUEST) COURSE DURATION: 3 DAYS Course Summary: The implementation course provides the participant with an in-depth level of
More information