1 Open System Architecture Selecting the Right Cable and Connectivity for Your Application Kenneth Cornelison Industry Consultant Wire and Cable Technology Engineering Resources

2 Key Discussion Points TIA system structure overview Component Ratings rated and verified Interoperability testing across different connectivity solutions Survey to evaluate performance across connectivity solutions Information valuable for system warranty content and scope Manufacturer system warranties - Key elements and attributes Summary

3 TIA and Standards Structure TIA Family of documents ranging from system to components Component, system, installation guidance and requirements IEC has similar set of documents for cables and structured cabling systems BICSI accreditation, ti standards d and document structure t

4 TIA Standards Overview Common standards - TIA 568; 569; 606; etc. Cover building, installation, administration Premise Standards - TIA 570; 758; 942; etc. Premises standards - Infrastructure Component Standards - TIA 568 Copper and Fiber

5 Rapidly Growing Technical Requirements TIA Cabling Standards Category 3: Cables and outlets up to 16 MHz. Category 5e: Cables and outlets up to 100 MHz with enhanced characteristics over cat 5. Category 6 : Cables and outlets up to 250 MHz. Category 6a : Cables and outlets up to 500MHz for 10Gbit Ethernet operation. ISO/IEC Cabling Classes - Similar structure to the TIA Class C Up to 16 MHz Category 3 Class D Up to 100 MHz Category 5e Class E Up to 250 MHz Category 6 Class Ea Up to 500MHz Category 6a (amend 1&2) Class F Up to 600 MHz Class Fa Up to 1000MHz (amend 1&2) NEXTGEN Category 8 Up to 2000MHz over 30m New Proposed Applications 2.5Gb, 5Gb and others

6 A Key Why to Standards Many reasons why for standards Common system and component characteristics facilitate system cost and ease of installation Interoperability for components and systems is one of the key reasons A basic premise of the Structured Cable System Encourages mass production, economies of scale, and broader applications Facilitates implementation of open system warranties Customer confidence Consistent and reliable performance

7 Compliant vs Verified Component Verification Third party vs internal testing and qualification Choosing components that t are independently d verified Warranties rely on verified components to assure performance

8 Structured Cabling Warranties and Performance Warranties are enhanced (and even enabled) by the standards and accreditation structure of TIA, IEC, BICSI and other organizations Warranty success depends on both the hardware performance and the installation skills of the installer Warranties available through certified installers An important result of having standards is the confidence in the market provided by standard components and installer skills

9 Project to Assess Link Performance Project initiated from a cable manufacturer s need to survey performance with recognized connectivity manufacturers Selection of widely used cable types and connectivity solutions Testing in Permanent link configuration

10 Testing Across Connectivity Manufacturers Purpose of Testing Cable manufacturers offer an open warranty on installed systems A need for an overall assessment of link performance for a range of approved connectivity solutions A way to confirm that the connectivity approval lists are appropriate for warranty coverage A snapshot verification of the open system architecture performance

11 90 Length of Category cable Cable test Establishing a Baseline Cable without connectors tested with automatic Network Analyzer (VNA) based test hardware as a baseline Key electrical parameters captured, including balance performance Good margin to both Cable and Permanent Link requirements

12 Conditions for Link Testing Permanent Link tested at 90m length Field tester used for testing All frequency sweep data exported and analyzed Performance margin and comparison to cable measurements summarized Permanent Link with two connections Terminal Outlet (TO) and Cross-connect (C1) Optional consolidation point (CP) not included

13 Testing Outline Multiple manufacturers of connectivity 6 for Category 6 UTP 6 for Category 6A UTP 3 for Category 6A FUTP Multiple tests for each combination Same length of cable used for all tests within Category family Cables listed and verified to TIA 568C.2 Limited number of operators following good practices Laboratory test environment

14 Category 6 Cable Baseline Results - NEXT (tested to 500MHz)

15 Category 6 RL and TCL Baseline Results (tested to 500MHz)

16 Cable vs Cable + Connector Electrical performance curves do change appearance when adding connectivity Split Pair Effects Connectivity design and circuitry Interaction with cable design

17 Cable and Cable + Connector A to Permanent Link Typical occurrence from all connectivity suppliers of an outlier NEXT response Overall, NEXT was the most variable across multiple connectors of the same supplier

18 Cat 6 Connector A Test Result Examples

19 Cat 6 Cable and Connector A Return Loss

20 Cat 6 Cable and Connector A TCL

21 NEXT Margin Data Overview Key Takeaway More variability than expected Main Remote

22 Return Loss Margin Data Example Consistency within a connector type

23 TCL Margin Data Example Consistency within a connector type

24 NEXT Permanent Link Performance Variability All connector types had variations from test to test But not all connector types had the same variation characteristics No one connector stood out across all combinations

25 Cat 6 NEXT Margin Variation Across 6 different manufacturers

26 Cat 6 NEXT Margin Variation Across 6 different manufacturers

27 Cat 6 NEXT Margin Variation Across 6 different manufacturers

28 Category 6 Testing Summary Even with the same cable from test to test, NEXT had the most variability from test to test Other parameters, such as TCL and RL were more consistent All tests met Permanent link requirements with margin Variability did not seem to differ whether at main or remote end of the cable

29 Category 6A UTP and FUTP Testing The same test procedure was followed for Category 6A components 90m baseline test on cable 90m links tested in a 2 connector arrangement Consistent operator and termination techniques

30 6A Permanent Link NEXT Margins Connector A

31 Cat 6A UTP More consistent NEXT, but not always the same

32 Category 6A UTP Testing Summary Overall, more NEXT consistency between tests, and between connectivity solutions than with Category 6 Consistency in the other electrical parameters (RL, TCL) among the different connectivity solutions Key attribute for 6A UTP links is Alien crosstalk, which may lead to more consistent results

33 Category 6A FUTP NEXT Summary

34 Category 6A FUTP FUTP data similar to the Category 6 UTP data Variable NEXT results from test to test Consistent data for RL, IL, TCL, and other tests

35 Permanent Link Data Summary All connectivity combinations pass the industry permanent link standards Good electrical performance allows the user the option of selecting connectivity across other key parameters with assured performance Ease of installation; cost; availability; manufacturer support Data supports warranties from cable maker across a range of connectivity options

36 Key Warranty System Attributes Requires industry standard component compliance and verification Provides guaranteed performance levels for installed system Supplier resources system support, technology, capabilities Establishes chain of communication for system performance, maintenance Establishes responsible parties for problem resolution Establishes a set of components and systems with reliable performance 3 rd party location for system test data retention Warranted channels can support multiple and new applications

37 Access to product specific information Training Resources Scope of covered products Hands-on opportunities

38 Open and Closed System Warranties Advantages of an open system warranty Choosing components to suit installation needs Flexibility for installers, system integrators Backed by Industry standard specifications and structure Closed solutions have advantages, but some drawbacks Some closed solutions are a specific example of an open solution available elsewhere There are fewer closed solutions from one manufacturer than closed solutions that use at least two different manufacturers Closed solutions that are multi-company can and do come and go over time Limited product/performance options Warranty restrictions out of network products risk the entire project warranty

39 Accredited Installations Move, add, change documentation?

40 Read the warranty first Does it have Warranty Fine Print Limited time (even a few days) to notify warranty provider of problems? Ability to transfer warranties? Void if components are more than a few months old? A choice of components to best meet the user overall needs Provider training resources providing BICSI credits? A milestone date when the warranty starts? Availability of support resources Installer, component manufacturers, etc Coverage for permanent link portion or end to end?

41 Summary Survey test results confirm performance meeting requirements There are differences among the components in the testing, but all meet requirements Variability from test to test observed even with relatively controlled testing environment Variability with both Category 6 and 6A links All components tested from a 3 rd party verified supplier Warranty decisions Knowledge of warranty coverage, details, and requirements Limitations within warranty for timing of key events, warranty scope, etc Use of components with 3 rd party verification services Flexibility in choosing components and installers

42 Thank You

ISO/IEC TR Guidance on 40GBASE-T T Cabling

ISO/IEC TR Guidance on 40GBASE-T T Cabling 1 ISO/IEC TR 11801-99 99-1 Guidance on 40GBASE-T T Cabling - a tutorial - Alan Flatman Principal Consultant LAN Technologies Email: a_flatman@tiscali.co.uk 2 Content 1. introduction to ISO/IEC SC25 WG3

More information

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India Enterprise Network Test Strategies for Network Availability and Performance A Sitaramaiah Director Fluke Networks India 1 Why is Enterprise Network Testing becoming increasingly important? IT is increasingly

More information

Single-pair cabling channel specifications

Single-pair cabling channel specifications Single-pair cabling channel specifications IEEE P802.3cg 10SPE Task Force October 25, 2017 Dave Hess, CORD DATA 10/25/2017 hess_10spe_01_1025 1 Overview JMTG organization and scope JMTG projects related

More information

Conformity Assessment Schemes and Interoperability Testing (1) Keith Mainwaring ITU Telecommunication Standardization Bureau (TSB) Consultant

Conformity Assessment Schemes and Interoperability Testing (1) Keith Mainwaring ITU Telecommunication Standardization Bureau (TSB) Consultant Conformity Assessment Schemes and Interoperability Testing (1) Keith Mainwaring ITU Standardization Bureau (TSB) Consultant Moscow, 9-11 november 2011 Contents The benefits of conformity assessment Conformity

More information

Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant

Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant Is Cable Balancing Efficient i Enough for EMI Mitigation in Data Centers? Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant What are You going to Learn? What are the potential sources

More information

Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS.

Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS. Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications Broadband High-Speed LAN Voice Robert Y. Faber Jr., RCDD/NTS Minimum Port Recommendations TIA/EIA-568-B.1 2 outlets

More information

Field-testing procedure. LANmark-6

Field-testing procedure. LANmark-6 Field-testing procedure LANmark-6 Technical Paper Nexans Cabling Solutions September 2006 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent link testing vs. Channel

More information

How new testing standards affect you Singapore, Nov 2009

How new testing standards affect you Singapore, Nov 2009 How new testing standards affect you Singapore, Nov 2009 Adrian Young Sr. Customer Support Engineer In this presentation, we will cover How ANSI/TIA-568-C.2 has consolidated all the different test plugs

More information

USDA ISO Guide 65 Program Accreditation for Certification Bodies

USDA ISO Guide 65 Program Accreditation for Certification Bodies Page 1 of 6 USDA ISO Guide 65 Program Accreditation for Certification Bodies 1 Purpose This document provides the requirements to be met in designing a USDA ISO Guide 65 Program. It also provides the requirements

More information

O p e A n rchitecture

O p e A n rchitecture Open Architecture What is Open Architecture? If you are installing a network infrastructure utilizing fiber optic, Category 5e, 6 or 6A components, there is a sizable selection of well known products available.

More information

White Paper: Installing Data Networks Using LinkWare Live SaaS

White Paper: Installing Data Networks Using LinkWare Live SaaS White Paper: Installing Data Networks Using LinkWare Live SaaS White Paper: Installing Data Networks Using LinkWare Live SaaS Software as a Service (SaaS) continues to grow in popularity across a wide

More information

NGBASE-T Cabling Requirements

NGBASE-T Cabling Requirements NGBASE-T Cabling Requirements Dr. T. C. Tan, DMTS, CommScope Labs B.Sc (Eng), DIC, PhD, CEng, FIET White paper www.commscope.com Contents Contents Contents 2 1.0 Introduction 3 2.0 IEEE 802.3 NGBASE-T

More information

ANSI/TIA/EIA-568-B Cabling Standard

ANSI/TIA/EIA-568-B Cabling Standard 73 ANSI/TIA/EIA-568-B Cabling Standard In the mid-1980s, consumers, contractors, vendors, and manufacturers became concerned about the lack of specifications relating to telecommunications cabling. Before

More information

Leveraging the Structured Cabling System for Security Applications. Mark Dearing, RCDD Leviton Network Solutions

Leveraging the Structured Cabling System for Security Applications. Mark Dearing, RCDD Leviton Network Solutions Leveraging the Structured Cabling System for Security Applications Mark Dearing, RCDD Leviton Network Solutions Trends - Cable Category Mix Source: Leviton projections based on market growth rates Over

More information

IEEE Conformity Assessment Program (ICAP) June12, 2013

IEEE Conformity Assessment Program (ICAP) June12, 2013 IEEE Conformity Assessment Program (ICAP) June12, 2013 Understanding Conformity Assessment Understanding Conformity Assessment What is Conformity Assessment? Conformity Assessment is defined as the process

More information

"IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI TRASMISSIVI FINO A 250 MHZ"

IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI TRASMISSIVI FINO A 250 MHZ "IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI TRASMISSIVI FINO A 250 MHZ" Gli standard per la categoria 6 e i nuovi strumenti di misura maurizio.malinconi@flukenetworks.com

More information

SPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING

SPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING PART 1: GENERAL 1.01 SCOPE OF WORK A. The Designer and Contractor are responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable to the

More information

40 Gigabit over copper - Thorsten Punke Marketing Manager ANZ TE Connectivity

40 Gigabit over copper - Thorsten Punke Marketing Manager ANZ TE Connectivity 40 Gigabit over copper - 40GBase-T Thorsten Punke Marketing Manager ANZ TE Connectivity IEEE 802.3 Ethernet Update 40GBase-T The history The technical truth The technical history More speed equals to more

More information

Get ready to overachieve.

Get ready to overachieve. Datasheet: DSX-5000 CableAnalyzer The DSX-5000 CableAnalyzer is the copper certification solution and is part of the Versiv cabling certification product family. The Versiv line also includes fiber OLTS

More information

Provided by

Provided by Provided by www.aaatesters.com Datasheet: DSX-5000 CableAnalyzer The DSX-5000 CableAnalyzer is the copper certification solution and is part of the Versiv cabling certification product family. The Versiv

More information

10 GIGABIT ETHERNET. 10GBASE-T Physical Layer Interoperability Test Suite Version 1.0. Technical Document. Last Updated: October 3, :30 PM

10 GIGABIT ETHERNET. 10GBASE-T Physical Layer Interoperability Test Suite Version 1.0. Technical Document. Last Updated: October 3, :30 PM . 10 GIGABIT ETHERNET 10GBASE-T Physical Layer Interoperability Test Suite Version 1.0 Technical Document Last Updated: October 3, 2008 2:30 PM 10 Gigabit Ethernet Consortium 121 Technology Drive, Suite

More information

CERTIFICATION ISSUES IN AUTOMOTIVE SOFTWARE

CERTIFICATION ISSUES IN AUTOMOTIVE SOFTWARE CERTIFICATION ISSUES IN AUTOMOTIVE SOFTWARE Speaker: Mario Fusani Systems and Software Evaluation Centre ISTI CNR, Pisa, Italy mario.fusani@isti.cnr.it 1 CONTENTS Certification What is certification? Definitions

More information

AMP-TWIST* 6S Series SL Jack

AMP-TWIST* 6S Series SL Jack Product Specification 108-93003 16/Mar/2011 Rev E AMP-TWIST* 6S Series SL Jack 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, AMP- TWIST*

More information

ALM120 Application Lifecycle Management 12.0 Essentials Gold Package

ALM120 Application Lifecycle Management 12.0 Essentials Gold Package Course Data Sheet ALM120 Application Lifecycle Management 12.0 Essentials Gold Package Course No: ALM120-120 For software version(s): Software version used in the labs: 12.0 Delivery formats: Instructor

More information

MOLEX PREMISE NETWORKS

MOLEX PREMISE NETWORKS MOLEX PREMISE NETWORKS Training Catalog Version 2.2 Bringing Advanced Physical Layer Lifecycle Management to Enterprises Worldwide Copper Fiber Wireless Advanced Physical Layer Management Advanced Physical

More information

Deploying NBASE-TTM 2.5G/5GBASE-T Technologies

Deploying NBASE-TTM 2.5G/5GBASE-T Technologies Deploying NBASE-TTM 2.5G/5GBASE-T Technologies George A. Zimmerman, Ph.D., CME Consulting Board of Directors, NBASE-T Alliance Peter Jones, Cisco Systems Chairman, NBASE-T Alliance Masood Shariff, CommScope

More information

Sources of Test Reports for TUV SUD BABT Product Certification BABT766. TUV SUD BABT is a certification body of. TUV SUD BABT 2015 Issue 7

Sources of Test Reports for TUV SUD BABT Product Certification BABT766. TUV SUD BABT is a certification body of. TUV SUD BABT 2015 Issue 7 BABT766 Sources of Test Reports for TUV SUD BABT Product Certification TUV SUD BABT is a certification body of TUV SUD BABT 2015 Page 1 of 5 Contents 1 Introduction... 2 2 Background... 2 3 General...

More information

AMP-TWIST* Modular Jack, UTP, Category 6A

AMP-TWIST* Modular Jack, UTP, Category 6A Product Specification 5 July 13 Rev A AMP-TWIST* Modular Jack, UTP, Category 6A 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for TE Connectivity*, 6A UTP AMP-

More information

ITU Asia-Pacific Centres of Excellence Training on Conformity and Interoperability. Session 2: Conformity Assessment Principles

ITU Asia-Pacific Centres of Excellence Training on Conformity and Interoperability. Session 2: Conformity Assessment Principles ITU Asia-Pacific Centres of Excellence Training on Conformity and Interoperability Session 2: Conformity Assessment Principles 12-16 October 2015 Beijing, China Keith Mainwaring ITU Expert Agenda 1. Context

More information

Global Specification Protocol for Organisations Certifying to an ISO Standard related to Market, Opinion and Social Research.

Global Specification Protocol for Organisations Certifying to an ISO Standard related to Market, Opinion and Social Research. CONTENTS i. INTRODUCTION 3 ii. OVERVIEW SPECIFICATION PROTOCOL DOCUMENT DEVELOPMENT PROCESS 4 1. SCOPE 5 2. DEFINITIONS 5 3. REFERENCES 6 4. MANAGEMENT STANDARDS FOR APPROVED CERTIFICATION BODIES 6 4.1

More information

BPS Suite and the OCEG Capability Model. Mapping the OCEG Capability Model to the BPS Suite s product capability.

BPS Suite and the OCEG Capability Model. Mapping the OCEG Capability Model to the BPS Suite s product capability. BPS Suite and the OCEG Capability Model Mapping the OCEG Capability Model to the BPS Suite s product capability. BPS Contents Introduction... 2 GRC activities... 2 BPS and the Capability Model for GRC...

More information

CLi Overview. CLi Program Highlights

CLi Overview. CLi Program Highlights CLi Overview AFL is an industry leader in the development and manufacturing of fiber optic products and services. AFL is the first telecommunications company to offer a lifetime warranty* on end-to-end

More information

LANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S

LANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S LANmark-7A High-Speed COPPER Solution For 40 Gigabit Applications LANmark-7A High-Speed Copper Solution For 40 Gigabit and Beyond LANmark-7A copper cabling is able to support higher bandwidths and faster

More information

Requirements for Certification Bodies operating Certification against the PEFC International Chain of Custody Standard

Requirements for Certification Bodies operating Certification against the PEFC International Chain of Custody Standard PEFC INTERNATIONAL STANDARD Requirements for certification users PEFC ST 2003:2012 2012-07-16 Requirements for Certification Bodies operating Certification against the PEFC International Chain of Custody

More information

SAP PartnerEdge Program Guide for Authorized Resellers

SAP PartnerEdge Program Guide for Authorized Resellers SAP PartnerEdge Program Guide for Authorized Resellers Table of Contents 3 SAP PartnerEdge Program: Accelerating Your Growth Gain an Edge on Your Competition 5 Program Requirements: How to Become an Authorized

More information

COPPER COMMUNICATION CABLE MEASUREMENT

COPPER COMMUNICATION CABLE MEASUREMENT MEASURE HF/LF PARAMETERS OF INCREASINGLY COMPLEX COPPER COMMUNICATION CABLES IN A TRANSPARENT AND EFFICIENT WAY, WHILE ENSURING FULL TRACEABILITY OUR SOLUTION Automatic Test Equipment (ATE) must be used

More information

BABT766. Sources of Test Reports for TUV SUD BABT Product Certification. TUV SUD BABT is a certification body of

BABT766. Sources of Test Reports for TUV SUD BABT Product Certification. TUV SUD BABT is a certification body of BABT766 Sources of Test Reports for TUV SUD BABT Product Certification TUV SUD BABT is a certification body of Page 1 of 5 Contents 1 Introduction...2 2 Background...2 3 General...2 4 Laboratories within

More information

Cabling to Maximize n Wireless Performance

Cabling to Maximize n Wireless Performance Cabling to Maximize 802.11n Wireless Performance New IEEE 802.11n wireless networking products offer faster data rates and improved coverage, addressing the drawbacks of legacy wireless networking products.

More information

How to cable n Wireless Access Points

How to cable n Wireless Access Points How to cable 802.11n Wireless Access Points The 802.11n standard is an important advance in wireless Local Area Networks (LANs). In 2007, residential consumers began installing 802.11n products and in

More information

BICSI NxtGEN & Global Data Center Standards Update

BICSI NxtGEN & Global Data Center Standards Update BICSI NxtGEN & Global Data Center Standards Update Bob Faber, RCDD/NTS Siemon Global Accounts Manager Chair NEMA High Performance Wire & Cable Chair BICSI Standards Committee Vice Chair BICSI TI&M Committee

More information

SYSTIMAX SCS Power Sum Solution

SYSTIMAX SCS Power Sum Solution SYSTIMAX SCS Power Sum Solution Superior Performance for CAT 5 Networks Realize the Full Potential of Your CAT 5 Network... You ve made a significant investment in your data network. Every component meets

More information

The AMP NETCONNECT Category 6 Cabling System

The AMP NETCONNECT Category 6 Cabling System The AMP NETCONNECT Category 6 Cabling System 2 Table of Contents TABLE OF CONTENTS...3 PERSPECTIVE...4 WHY INSTALL NEXT GENERATION CABLING SYSTEMS?...4 MEGAHERTZ VS. MEGABITS...4 PLANNING FOR THE FUTURE...5

More information

CPD ACTIVITY GUIDELINES AND REQUIREMENTS

CPD ACTIVITY GUIDELINES AND REQUIREMENTS Introduction After obtaining the Internal Audit Technician (IAT) and / or Professional Internal Auditor (PIA)* designations, members must maintain their knowledge and skills and stay abreast of improvements

More information

InstaPATCH Cu Cabling Solutions for Data Centers

InstaPATCH Cu Cabling Solutions for Data Centers SYSTIMAX Solutions InstaPATCH Cu Cabling Solutions for Data Centers Design Guidelines August 2008 www.commscope.com Contents Overview 1 InstaPATCH Cu Solution Specification 2 Harness Assembly Design 3

More information

SCS FSC Chain-of-Custody Guidance for Certification of Multiple Sites FSC-STD V2-1

SCS FSC Chain-of-Custody Guidance for Certification of Multiple Sites FSC-STD V2-1 2000 Powell Street, Ste. 600 Emeryville, CA 94608 USA +1.510.452.8000 main +1.510.452.8001 fax www.scsglobalservices.com SCS FSC Chain-of-Custody Guidance for Certification of Multiple Sites FSC-STD-40-003

More information

Atras Network Communications

Atras Network Communications Atras Network Communications Guide to Information and Communications Technology (ICT) Standards developed and published by the Telecommunications Industry Association (TIA) The Telecommunications Industry

More information

Certification Requirements Competency-based Environmental Management Systems (EMS) Certification Program

Certification Requirements Competency-based Environmental Management Systems (EMS) Certification Program Certification Requirements Competency-based Environmental Management Systems (EMS) Certification Program Exemplar Global Personnel Certification Programs Exemplar Global is accredited by the Joint Accreditation

More information

Summary of PIC/S Guidance Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments

Summary of PIC/S Guidance Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments www.rx-360.org Summary of PIC/S Guidance Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments Draft Published August 2016 This summary was prepared by the Rx-360 Monitoring

More information

Copper Riser And Intrabuilding Cabling

Copper Riser And Intrabuilding Cabling Copper Riser And Intrabuilding Cabling PART 1: GENERAL The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable

More information

Accelerate GDPR compliance with the Microsoft Cloud

Accelerate GDPR compliance with the Microsoft Cloud Regional Forum on Cybersecurity in the Era of Emerging Technologies & the Second Meeting of the Successful Administrative Practices -2017 Cairo, Egypt 28-29 November 2017 Accelerate GDPR compliance with

More information

IEEE GBASE-T Study Group Closing Plenary Meeting Report

IEEE GBASE-T Study Group Closing Plenary Meeting Report IEEE 802.3 10GBASE-T Study Group Closing Plenary Meeting Report San Francisco, CA July 24, 2003 Brad Booth, Chair bbooth@ieee.org Presentations AbuGhazaleh; Alien NEXT, IL Effect on Channel Capacity Bohbot;

More information

Ethernet Cable Testing, Certifying & Diagnostics Jim Ralston Director of Sales

Ethernet Cable Testing, Certifying & Diagnostics Jim Ralston Director of Sales Softing Industrial Automation Data Exchange & Network Diagnostic Solutions Ethernet Cable Testing, Certifying & Diagnostics Jim Ralston Director of Sales Topics Softing Introduction Industrial Network

More information

Benefits of Accredited Conformity Assessment and the Supply Chain

Benefits of Accredited Conformity Assessment and the Supply Chain Benefits of Accredited Conformity Assessment and the Supply Chain By Sheronda Jeffries and Carmine Reda Companies purchase lots of things. They purchase tangible goods, such as raw materials and equipment;

More information

ITIL Intermediate Continual Service Improvement (CSI) Certification Boot Camp - Brochure

ITIL Intermediate Continual Service Improvement (CSI) Certification Boot Camp - Brochure ITIL Intermediate Continual Service Improvement (CSI) Certification Boot Camp - Brochure Gain Knowledge to Align IT Services to Business Needs US Course Name : CISSP Version : INVL_CISSP_BR_02_089_1.2

More information

This qualification has been reviewed. The last date to meet the requirements is 31 December 2018.

This qualification has been reviewed. The last date to meet the requirements is 31 December 2018. NZQF NQ Ref 1498 Version 2 Page 1 of 18 National Diploma in Business (Level 5) with optional strands in Accounting, Finance, Finance - Māori, Health and Safety, Human Resource, Māori Business and, Marketing,

More information

Softing PROFINET Diagnostic Tools

Softing PROFINET Diagnostic Tools Industrial Automation Softing PROFINET Diagnostic Tools Written by Dave Tomlin, Automation Specialist, Hitex (UK) Ltd Softing is one of the leading manufacturers of PROFINET diagnosis tools. Their tools

More information

ISO Certification For Laboratory Accreditation. Dr Amadou TALL Consultation

ISO Certification For Laboratory Accreditation. Dr Amadou TALL Consultation ISO 17025 Certification For Laboratory Accreditation Dr Amadou TALL Consultation ISO 17025 Certification ISO/IEC 17025 Global quality standard for testing and calibration laboratories. It is the basis

More information

Key Items: - Customer Premises Cabling - 1 ISO/IEC SC25/WG3 Meeting Milan: Sep 2015

Key Items: - Customer Premises Cabling - 1 ISO/IEC SC25/WG3 Meeting Milan: Sep 2015 1 ISO/IEC SC25/WG3 Meeting Milan: 07-10 Sep 2015 - Customer Premises Cabling - Key Items: 1. ISO/IEC 11801 Ed.3 major revision - 1 st CD has had a thorough review & has been re-issued as 2 nd CD 2. ISO/IEC

More information

Screened vs Unscreened Cabling

Screened vs Unscreened Cabling Screened vs Unscreened Cabling White paper White Paper Screened vs Unscreened Cabling v1.0 1 Introduction A global standard since the 1980s, screened and shielded twisted-pair copper cabling varieties

More information

2010/SOM3/CTI/WKSP/015rev1 Authorized Economic Operator Pilot Programme of Hong Kong, China

2010/SOM3/CTI/WKSP/015rev1 Authorized Economic Operator Pilot Programme of Hong Kong, China 2010/SOM3/CTI/WKSP/015rev1 Authorized Economic Operator Pilot Programme of Hong Kong, China Submitted by: Hong Kong, China Ease of Doing Business Workshop on Trading Across Borders Sendai, Japan 18-19

More information

Security Secure Information Sharing

Security Secure Information Sharing ASD Convention Workshop 6 e-standards: a Strategic Asset across the Value Chain Security Secure Information Sharing Steve SHEPHERD Executive Director UK CeB Istanbul, 6 October 2011 1 Information security

More information

EXAM PREPARATION GUIDE

EXAM PREPARATION GUIDE When Recognition Matters EXAM PREPARATION GUIDE PECB Certified ISO/IEC 27002 Manager www.pecb.com The objective of the PECB Certified ISO/IEC 27002 Manager examination is to ensure that the candidate has

More information

ENSURING INTEROPERABILITY FOR OPEN NETWORKING SYSTEMS WHITE PAPER. March 10, 2016

ENSURING INTEROPERABILITY FOR OPEN NETWORKING SYSTEMS WHITE PAPER. March 10, 2016 March 10, 2016 ENSURING INTEROPERABILITY FOR OPEN NETWORKING SYSTEMS WHITE PAPER PRESENTED BY: CHRISTINA DUBE (UNH-CRC), DANIEL GRAY (UNH-IOL), DAVID WOOLF (UNH-IOL) 21 MADBURY RD, SUITE 2 DURHAM, NH 03824

More information

SYSTIMAX GigaSPEED Xpress Solution Design Guidelines

SYSTIMAX GigaSPEED Xpress Solution Design Guidelines Design Guidelines Issue 2 August 2010 Contents 1.0 Overview 3 2.0 Power Separation 4 3.0 Bonding and Grounding 4 4.0 Administration and Labeling 5 5.0 General Cable Guidelines 5 6.0 Bundling and Alien

More information

ISO/IEC INTERNATIONAL STANDARD. Conformity assessment Requirements for bodies certifying products, processes and services

ISO/IEC INTERNATIONAL STANDARD. Conformity assessment Requirements for bodies certifying products, processes and services INTERNATIONAL STANDARD ISO/IEC 17065 First edition 2012-09-15 Conformity assessment Requirements for bodies certifying products, processes and services Évaluation de la conformité Exigences pour les organismes

More information

LAN Standards, News & Trends Update 2017 June 15, 2017

LAN Standards, News & Trends Update 2017 June 15, 2017 LAN Standards, News & Trends Update 2017 June 15, 2017 Greg Olson Jtech Systems, Inc Infrastructure Specialist Greg@jtechreps.com 425-437-1962 Our Objectives Review new & ongoing applications work in IEEE

More information

Hitachi Cable America and Optical Cable Corporation STRUCTURED CABLING SOLUTIONS. MOving data

Hitachi Cable America and Optical Cable Corporation STRUCTURED CABLING SOLUTIONS. MOving data Hitachi Cable America and Optical Cable Corporation STRUCTURED CABLING SOLUTIONS TM MOving data TM MOving data Just as a water infrastructure is essential to modern life, information is critical to the

More information

Advanced Security Tester Course Outline

Advanced Security Tester Course Outline Advanced Security Tester Course Outline General Description This course provides test engineers with advanced skills in security test analysis, design, and execution. In a hands-on, interactive fashion,

More information

Certification Report

Certification Report Certification Report Symantec Security Information Manager 4.8.1 Issued by: Communications Security Establishment Certification Body Canadian Common Criteria Evaluation and Certification Scheme Government

More information

Structured Cabling Organizations and Standards

Structured Cabling Organizations and Standards since 1976 Structured Cabling Organizations and Standards Key cabling infrastructure standards ANSI/TIA ISO/IEC 724-746-5500 blackbox.com IEEE Introduction Table of Contents The importance of standards...

More information

An Overview of ISO/IEC family of Information Security Management System Standards

An Overview of ISO/IEC family of Information Security Management System Standards What is ISO/IEC 27001? The ISO/IEC 27001 standard, published by the International Organization for Standardization (ISO) and the International Electrotechnical Commission (IEC), is known as Information

More information

NZQF Ref 1499 Version 3 Page 1 of 14. This qualification has been reviewed. The last date to meet the requirements is 31 December 2019.

NZQF Ref 1499 Version 3 Page 1 of 14. This qualification has been reviewed. The last date to meet the requirements is 31 December 2019. NZQF Ref 1499 Version 3 Page 1 of 14 National Diploma in Business (Level 6) Level 6 Credits 120 This qualification has been reviewed. The last date to meet the requirements is 31 December 2019. Version

More information

Introduction to Conformity Assessment and ISO/CASCO Tool Box

Introduction to Conformity Assessment and ISO/CASCO Tool Box www.aeconformity.com Introduction to Conformity Assessment and ISO/CASCO Tool Box Alex Ezrakhovich Co-convener of APG & AAPG Sydney, Australia 5th International Conference on Quality Management October

More information

Using PXI, TestStand, LabVIEW and some ingenuity to create a high throughput solution

Using PXI, TestStand, LabVIEW and some ingenuity to create a high throughput solution Using PXI, TestStand, LabVIEW and some ingenuity to create a high throughput solution Presenter: Paul Attwell CEng. Customer Application Specialist, Circuit Check 1 Introduction Hardware Software Sum up

More information

Tarleton State University. Specifications

Tarleton State University. Specifications Tarleton State University Campus Communication Infrastructure Specifications Cabling Standards Summary This document identifies Tarleton State University communication infrastructure standards. The communication

More information

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit Optimization and Speed: Two Critical Standards Enabling Next Generation Networks Stephanie Montgomery, TIA Brett Lane, Panduit Structure of TIA Standards 2 A family of Standards ANSI/TIA-942-A Telecommunications

More information

An Introduction to the ISO Security Standards

An Introduction to the ISO Security Standards An Introduction to the ISO Security Standards Agenda Security vs Privacy Who or What is the ISO? ISO 27001:2013 ISO 27001/27002 domains Building Blocks of Security AVAILABILITY INTEGRITY CONFIDENTIALITY

More information

V-PWR Data Center Program Guide

V-PWR Data Center Program Guide V-PWR Data Center Program Guide P V-PWR Data Center Overview Virtualization remains a critical component of making the data center more efficient. Arrow s V-PWR Data Center program provides our NetApp

More information

IEEE RTPGE. Optimisation of physical layer components for RTPGE. Thomas Müller, Gunnar Armbrecht, Stephan Kunz (Rosenberger)

IEEE RTPGE. Optimisation of physical layer components for RTPGE. Thomas Müller, Gunnar Armbrecht, Stephan Kunz (Rosenberger) Optimisation of physical layer components for RTPGE Thomas Müller, Gunnar Armbrecht, Stephan Kunz (Rosenberger) Supporters: Mehmet Tazebay (Broadcom) Thomas Suermann (NXP) Rosenberger Hochfrequenztechnik

More information

Testing and Measurement Technology. Handbook of Cable Testing. Fault Analysis Documentation and Reporting. h ps://itnetworks.softing.

Testing and Measurement Technology. Handbook of Cable Testing. Fault Analysis Documentation and Reporting. h ps://itnetworks.softing. Testing and Measurement Technology Handbook of Cable Testing h ps://itnetworks.softing.com Fault Analysis Documentation and Reporting Editorial On the way to new frontiers High-quality copper wiring in

More information

eguide: Designing a Continuous Response Architecture 5 Steps to Reduce the Complexity of PCI Security Assessments

eguide: Designing a Continuous Response Architecture 5 Steps to Reduce the Complexity of PCI Security Assessments eguide: Designing a Continuous Response Architecture 5 Steps to Reduce the Complexity of PCI Security Assessments Today s PCI compliance landscape is one of continuing change and scrutiny. Given the number

More information

VOLUNTARY CERTIFICATION SCHEME FOR MEDICINAL PLANT PRODUCE REQUIREMENTS FOR CERTIFICATION BODIES

VOLUNTARY CERTIFICATION SCHEME FOR MEDICINAL PLANT PRODUCE REQUIREMENTS FOR CERTIFICATION BODIES VOLUNTARY CERTIFICATION SCHEME FOR MEDICINAL PLANT PRODUCE 1. Scope REQUIREMENTS FOR CERTIFICATION BODIES 1.1 This document describes the requirements the Certification Bodies (CBs) are expected to meet

More information

FOUNDATION CERTIFICATE IN INFORMATION SECURITY v2.0 INTRODUCING THE TOP 5 DISCIPLINES IN INFORMATION SECURITY SUMMARY

FOUNDATION CERTIFICATE IN INFORMATION SECURITY v2.0 INTRODUCING THE TOP 5 DISCIPLINES IN INFORMATION SECURITY SUMMARY FOUNDATION CERTIFICATE IN INFORMATION SECURITY v2.0 INTRODUCING THE TOP 5 DISCIPLINES IN INFORMATION SECURITY SUMMARY The Foundation Certificate in Information Security (FCIS) course is designed to provide

More information

COMMON CRITERIA CERTIFICATION REPORT

COMMON CRITERIA CERTIFICATION REPORT COMMON CRITERIA CERTIFICATION REPORT HP Service Manager v9.41 Patch 3 383-4-395 17 February 2017 v1.0 Government of Canada. This document is the property of the Government of Canada. It shall not be altered,

More information

IAF Mandatory Document KNOWLEDGE REQUIREMENTS FOR ACCREDITATION BODY PERSONNEL FOR INFORMATION SECURITY MANAGEMENT SYSTEMS (ISO/IEC 27001)

IAF Mandatory Document KNOWLEDGE REQUIREMENTS FOR ACCREDITATION BODY PERSONNEL FOR INFORMATION SECURITY MANAGEMENT SYSTEMS (ISO/IEC 27001) IAF Mandatory Document KNOWLEDGE REQUIREMENTS FOR ACCREDITATION BODY PERSONNEL FOR INFORMATION SECURITY MANAGEMENT SYSTEMS (ISO/IEC 27001) (IAF MD 13:2015) Issue 1 IAF MD - Knowledge Requirements for Accreditation

More information

MasterCard NFC Mobile Device Approval Guide v July 2015

MasterCard NFC Mobile Device Approval Guide v July 2015 MasterCard NFC Mobile Device Approval Guide v2.0 30 July 2015 Notices Following are policies pertaining to proprietary rights, trademarks, translations, and details about the availability of additional

More information

EXAM PREPARATION GUIDE

EXAM PREPARATION GUIDE When Recognition Matters EXAM PREPARATION GUIDE PECB Certified ISO 31000 Risk Manager www.pecb.com The objective of the PECB Certified ISO 31000 Risk Manager examination is to ensure that the candidate

More information

ISO/IEC Information technology Security techniques Code of practice for information security controls

ISO/IEC Information technology Security techniques Code of practice for information security controls INTERNATIONAL STANDARD ISO/IEC 27002 Second edition 2013-10-01 Information technology Security techniques Code of practice for information security controls Technologies de l information Techniques de

More information

SMA CERTIFICATION PROGRAM

SMA CERTIFICATION PROGRAM SMA CERTIFICATION PROGRAM SMA Education Committee Certified Company Education is the key, unlock your Future SMA Certification Vision: Provide education, and skill development by offering SMA members viable

More information

FIELD TESTER CAPABILITY FOR BALANCE MEASUREMENT

FIELD TESTER CAPABILITY FOR BALANCE MEASUREMENT FIELD TESTER CAPABILITY FOR BALANCE MEASUREMENT Everett, WA theo.brillhart@flukenetworks.com Brillhart 8.3bq NGBT Task Force Geneva, 3 INTRODUCTION Definitions of Balance measurements. Measurement Procedures

More information

Central Management System Equivalent Meter Test Specification

Central Management System Equivalent Meter Test Specification Guidance Central Management System Equivalent Meter Specification Purpose The purpose of this document is to specify the testing required for approval as a Central Management System Equivalent Meter. Contents

More information

ITIL Intermediate: Service Transition. Lesson Plan. Mock Exam: Duration: Language: Included in Course (x2) 21 hours, self-paced English

ITIL Intermediate: Service Transition. Lesson Plan. Mock Exam: Duration: Language: Included in Course (x2) 21 hours, self-paced English ITIL Intermediate: Lesson Plan Delivery: e-learning Certificate: Examination (included) Accredited By: EXIN Mock Exam: Duration: Language: Included in Course (x2) 21 hours, self-paced English This Lesson

More information

INFORMATION SECURITY & ISO 27001

INFORMATION SECURITY & ISO 27001 INFORMATION SECURITY & ISO 27001 AN INTRODUCTION January 2018 Protect Comply Thrive INFORMATION SECURITY & ISO 27001 Introduction Information security is one of the central concerns of the modern organisation.

More information

CCNA Discovery 4.0 Designing and Supporting Computer Networks

CCNA Discovery 4.0 Designing and Supporting Computer Networks CCNA Discovery 4.0 Designing and Supporting Computer Networks Characterizing Existing Network Chapter 3 1 Objectives 2 Creating a Network Diagram Typically, the first step in installing a new network is

More information

Procedure for Network and Network-related devices

Procedure for Network and Network-related devices Lloyd s Register Type Approval System Type Approval Requirements for components within Cyber Enabled Systems on board Ships Procedure for Network and Network-related devices September 2017 1 Reference:

More information

Candidate Manual Certified Commissioning Firm (CCF) Program

Candidate Manual Certified Commissioning Firm (CCF) Program Candidate Manual Certified Commissioning Firm (CCF) Program Building Commissioning Certification Board 1600 NW Compton Drive, Suite 200 Beaverton, OR 97006 Phone: 1-877-666-BCXA (2292) E-mail: certification@bcxa.org

More information

PacNOG-21. Migrating to IPv6 : Experiences from Asia-Pacific

PacNOG-21. Migrating to IPv6 : Experiences from Asia-Pacific PacNOG-21 Migrating to IPv6 : Experiences from Asia-Pacific Goals for a Sustainable Future : The SDGs 17 Sustainable Development Goals and 169 Targets Available for download at http://www.itu.int/en/itu-d/statistics/pages/publications/mis2017.aspx

More information

www.ipc.org/validation EMS & SUPPLIERS WIN When your company earns an IPC Validation Services certification, you ve proven that you are committed to delivering a higher level of quality. And that opens

More information

ITIL. Change Manager. ITSM Academy

ITIL. Change Manager. ITSM Academy ITIL V3 Roles and Responsibilities Change Manager 1 About ITSM Academy Certified Woman Owned Business Accredited ITSM Education Provider ITIL Foundation/Bridge, V3 Capability, V2 Practitioner, Service

More information

Siemon Interconnect Solutions

Siemon Interconnect Solutions Siemon Interconnect Solutions W W W. S I E M O N. C O M / S I S technology at work for you DESIGN ENGINEERING Our Product Development Engineers and R&D Lab combine state of the art tools and capabilities

More information