UCS Supported Storage Architectures and Best Practices with Storage

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "UCS Supported Storage Architectures and Best Practices with Storage"

Transcription

1

2 UCS Supported Storage Architectures and Best Practices with Storage

3 First Things First: Debunking a Myth Today (June 2012 UCS 2.01x) there is no FCoE northbound of UCS unless you really, really, really want to That s right, there is no FCoE on external Ethernet uplinks by default In other words, FCoE is used only at the access layer (Server to Fabric Interconnect) in a totally transparent manner You don t need to know anything about FCoE to understand how storage works with UCS Everything works as usual. Servers have HBAs that FLOGI into the SAN fabric, you use zoning and LUN masking just like you do with rackmounts today UCS release 1.4 introduced support for Direct Connect FCoE targets Today, this is the only case where you ll see FCoE traffic You ll have to go through explicit configuration steps to make this happen 3

4 Exec Summary: UCS 1.4 Storage Features New Direct Connect Topologies Introduced Allows lower cost point for small UCS Pod like deployments Remote Location scenarios Use of FCoE Storage Targets with UCS FC Port Channeling and VSAN Trunking More flexibility in engineering FC traffic vs. 1 VSAN per uplink Aggregate Uplinks transparent to host Multi-path drivers Requires MDS or N5K to Work (both features) 4

5 Exec Summary: UCS 2.0 Storage Features iscsi Boot Support Integrated boot policies, stateless support iscsi HBA modeling (identifiers, equipment view, etc) M81KR (Palo) and Broadcom Support Hard Disk Drive (HDD) Monitoring without an OS agent Use of LSI interfaces and exposed metrics 5

6 Topics Introduction of Converged Network Adapters (CNAs) CNAs and Port WWNs Considerations UCS Storage modes of operation and recommendations End Host Mode - NPV (N_Port Virtualization) FC Switching Mode Upstream Connectivity F_Port Trunking / F_Port Channeling Direct Connectivity of Storage Port Types What works and what doesn t IP-Based Storage Appliance Ports iscsi Troubleshooting 6

7 Introduction of Converged Network Adapters CNAs and Port WWNs Considerations

8 Unified Fabric with FCoE CNA: Converged Network Adapter Nexus Edge participates in both distinct FC and IP Core topologies CNA presents multiple PCI addresses to the Operating System (OS) OS loads two unique sets of drivers and manages two unique application topologies Server participates in both topologies since it has two stacks and thus two views of the same unified wire Host FC Multi-Pathing driver provides failover between two fabrics (SAN A and SAN B ) UCS hardware based Fabric Failover (preferred) or OS NIC Teaming provides Ethernet traffic failover FCF Unified Wire shared by both FC and IP topologies Ethernet Driver bound to Ethernet NIC PCI address 10GbE Ethernet Drivers Fibre Channel 10GbE Link PCIe Operating System Ethernet Fibre Channel Drivers FCF Nexus Unified Edge supports both FC and IP topologies FC Driver bound to FC HBA PCI address 8

9 CNA: Converged Network Adapter Operating System View Emulex / Qlogic Standard drivers Same management Operating System sees: N port or Dual port (depending on hardware) 10 Gigabit Ethernet adapter N port or Dual Port (depending on hardware) Fibre Channel HBAs 9 9

10 CNA: Converged Network Adapter Operating System View Cisco M81KR (Palo) Standard drivers Same management Operating System sees: N port or Dual port (depending on hardware) 10 Gigabit Ethernet adapter N port or Dual Port (depending on hardware) Fibre Channel HBAs 10

11 vhbas: WWN Assignment WWN assignment: just like Ethernet MAC addresses Either inherited from burnt-in WWN (not with M81KR!) Or manually set Or borrowed from a pool (recommended) Up to two HBAs (called vhbas) per server with non-m81kr CNAs Backplane path failover does not exist for HBAs! A vhba either goes through switch A or B at any given time OS-level multipathing provides path resiliency Same dynamic pinning concept as with 10GE NICs Manual override allowed by using SAN pin-groups 11

12 A word on World-Wide Name Formats Avoid interop issues by choosing IEEE Extended Type 2 WW Names inside pools: Section 1 Section 2 Section 3 Section 4 2 0:00 00:25:B5 XX:XX:XX Section 1 identifies the WWN as an extended format WWN Section 2 is a vendor specific code and can be used to identify specific ports on a node or to extend the serial number (section 4) of the WWN Section 3 identifies the vendor (00:25:B5 = Cisco) Section 4 is the serial number for the device 12

13 Best Practice for WWN Pools Cisco MDS switches will not let just any random port WWN FLOGI! Diagnostic is not trivial. If your vfc (server-side) interface does not come up, check for malformed WWNs on the upstream MDS using show flogi internal eventhistory errors Event:E_DEBUG, length:146, at usecs after Fri Sep 4 17:55: [102] Err(NAA=5 and IEEE Company ID is zero)invalid node name 50:00:00:00:00:00:00:07 from interface fc1/9; nport name is 20:00:00:00:00:00:04:02. As stated on the previous slide, prefer IEEE Type 2 WWNs 13

14 Quick Tip How Do I Determine My Port WWNs? Determine the server s pwwn Assigned through the service profile Verify on the host it will match: Check local FLOGI for that pwwn on UCS and MDS: On Windows, use free fcinfo.exe utility 14

15 Fabric Interconnects Modes of Operation

16 What is NPV? N-Port Virtualizer (NPV) utilizes NPIV functionality to allow a switch to act like a server performing multiple logins through a single physical link Physical servers connected to the NPV switch login to the upstream NPIV core switch Physical uplink from NPV switch to FC NPIV core switch does actual FLOGI Subsequent logins are converted (proxy) to FDISC to login to upstream FC switch No local switching is done on an FC switch in NPV mode FC edge switch in NPV mode Does not take up a domain ID UCS Fabric Interconnect FC NPIV Core Switch F-Port Eth1/1 Server1 N_Port_ID 1 NP-Port F-Port Eth1/2 Server2 N_Port_ID 2 F_Port Eth1/3 Server3 N_Port_ID 3 N-Port 16

17 N-Port Virtualization (NPV) Mode UCS FI works in NPV mode by default Server-facing ports are regular F ports Uplinks toward SAN core fabric are NP ports UCS distributes (relays) FCIDs to attached devices No domain ID to maintain locally Zoning, FSPF, DPVM, etc are not configured on the UCS Fabrics Domain Mgr, FSPF, Zone Server, Fabric Login Server, Name Server They do not run on UCS Fabrics No local switching All FC traffic routed via the core SAN switches 17

18 N-Port Virtualization (NPV): An Overview 1) FI FLOGIs to NPV Core 2) Server FLOGIs to FI 3) NPV Converts Server FLOGIs to FDISCs NPV-Core Switch (MDS or 3 rd party switch with NPIV support) FC F-port NP-port F-ports N-ports chassis chassis chassis Can have multiple uplinks one VSAN per uplink Two uplinks can be in the same VSAN Port channel or trunking optional UCS FI A & B Relays FCIDs to servers no domain ID to configure on UCS! Servers log in (FLOGI) locally 18

19 NPV: Internal Logins (FLOGIs) When an NP port comes up, UCS itself first FLOGIs into the core Pod UCS rtp-6100-a F VSAN 100 NP fc2/1 P1 P2 fwwn of Port P1 19

20 NPV: Logins from Servers (FDISCs) Server HBAs log into the npv-core as follows: Pod F P1 UCS rtp-6100-a VSAN 100 NP fc2/1 vfc688 P2 F P3 fwwn of Port P2 fwwn of Port P1 N P4 Server 1/3 NPV converts FLOGI to FDISC CSCO8000 FCID 0xe

21 UCS Storage Defaults and Recommendations for FC Default (recommended) - N_Port Virtualization (NPV) Mode End Host Mode for FC, UCS functions as Node Port (initiator) Small to Large Scale Deployments of homogeneous or heterogeneous operating systems Extensive interoperability with SAN and array ecosystem Option - FC Switching Mode UCS FI has limited FC switching features, No Zoning Configuration Must still have upstream MDS or Nexus FC switch via FC Uplink Direct Connect from Fabric Interconnect to Storage Array FC target Designed for POD or Small scale Limited interoperability with Storage ecosystem 21

22 UCS Storage Defaults and Recommendations for FCoE Default FCoE Traffic is internal to UCS system (blade to Fabric Interconnect) FCoE packets are terminated at the fabric interconnect, no northbound FCoE packets transmitted from UCS Options FC Switching Mode UCS FI has limited FC switching features, no zoning configuration Must still have upstream MDS or Nexus FC switch via FC Uplink Direct Connect from Fabric Interconnect to Storage Array(s) FCoE target Use of FCoE Storage Targets with UCS Limited interoperability with Storage ecosystem 22

23 UCS Storage Defaults and Recommendations for NAS Default (recommended) - End Host Mode Superior traffic engineering - Native L2 multipathing; no spanning-tree Easier integration into network 1.4 Introduced Appliance Ports which allow direct connect NAS filers Options - Ethernet Switching Mode As of 1.4 no storage based reasons to use this mode Previous releases required switching mode for direct connect NAS 23

24 UCS Connectivity Summary LAN CLOUD SAN Switch Upstream Switch in NPIV Mode FC STORAGE NAS STORAGE LAN Switch UCS Ethernet in EHM UCS FC in NPV Mode UCS Fabric Interconnect Access Layer LAN & SAN Unified Fabric (FCoE) 24

25 Upstream Connectivity SAN Uplinks, Port Channels and Trunks

26 FC Uplink VSAN Membership Default SAN integration is very straightforward: Connect UCS to external SAN switch (MDS / Brocade) Make FC uplink member of one and only one VSAN No F_Port or NP_Port trunking by default 26

27 FC Port Trunking (Multiple VSANs per Link) Provide isolation to SAN traffic over the same physical FC link Help consolidate FC infrastructure vhbas can be on different VSANs Uplink FC ports will be in NPV mode (N- Port) by default All VSANs will be trunked on every uplink FC port vfcs Selecting a subset of VSANs for individual uplink ports not supported Scalability: Max of 32 VSANs per UCS system VSAN trunking supported in FC switch mode as well VSAN 100 VSAN 200 VSAN 300 VSAN 400 VSAN Trunking is not available for direct connect FC (or FCoE) Storage Port types SAN A SAN B 27

28 FC Port Channels Aggregate and maximize available bandwidth while maintaining isolation Increases resiliency and guard against port failures Up to 16 FC ports can be aggregated together for a single port channel Different combination of FC ports from different expansion modules on the FI can be placed on the same port channel vfcs In case of port speed mismatch port channel forces port speed to highest commonly supported speed VSANs can be trunked over the port channel Port Channel VSAN 100 VSAN 200 VSAN 300 VSAN trunking and port channel supported for both NPV and switch mode FI operation FC Port channeling is not available for direct connect FC Storage Port types SAN A SAN B VSAN

29 How FC Trunking is Enabled (Global) Global Setting for both FIs Default is Not enabled 29

30 Creation and Management of FC Port Channels 30

31 FC Port Channeling Requirements and Defaults Must activate the channel (like Ethernet) Can work in NPV or FC switch mode MDS and N5K only Load Balancing algorithm same as N5K Load balancing is based on the source ID, destination ID, and exchange ID (OX ID). Storage FC ports cannot be channeled or trunked SJ2-151-B26-A(nxos)# show interface fc 2/1 fc2/1 is up Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN) Port WWN is 20:41:00:05:73:a2:b3:00 Admin port mode is F, trunk mode is off 31

32 FC Port Channel and Trunking Interoperability Caveats If the UCS system has VSAN configured in the range of and an attempt is made to enable Port Channel or Trunk, a dialog will indicate configured VSANs in that range will go disabled. This is due to those VSANs being reserved starting with NX-OS 4.1 in order to support port-channel/trunk features. This will cause those VSANs to stop switching traffic on those VSANs. NOTE: MDS and UCS FI restricted VSAN ranges are not identical. 32

33 Fabric Interconnects FC and Direct Storage Connectivity Options

34 FC SAN Boot Create Service Profile Configure Storage (simple or expert) Create vhba s (1, 2, or more (M81KR)) Assign Initiator WWPN (manual or pool) Assign VSAN to vhba s Assign vhba Placement Select or Create Boot Policy Assign Target WWPN and LUNID Associate Server Zone Mask Boot to vmedia Install Drivers and OS 34

35 Enable Direct Connection of FC/FCOE Storage Customer benefits Support to directly connect FC/ FCoE storage to 6100 End to end FCoE topologies possible Lower cost point for small deployments (no access layer FC switches) FCoE Storage FC Storage Feature details Support for NetApp and EMC direct attached storage Ability to turn On/Off Fibre Channel switching mode Zoning configuration not exposed with UCS Manager Zoning must be inherited from upstream switch Ethernet and FC switching modes are independent UCS 6100 UCS 6100 UCS B-Series 35

36 Key Considerations of FC Direct Connect. No FC Zoning without upstream connection to MDS or N5K Upstream MDS/N5K allows zoneset merges but no zoning configuration exposed on UCS Software. As of April 2011 Cisco requires the use of upstream MDS/N5K to allow zoneset merges External SAN Management Software N5K MIBs are all exposed but READ ONLY 6xxx can be added to Fabric Manager (FM) but the manageability through FM is limited 36

37 UCS Direct Connect Storage Three UCS port types related to direct storage capability Storage FC Port direct connect this port to FC port on array Storage FCoE Port direct connect this port to FCoE port on array Appliance Port - direct connect this port to 10G Ethernet port on array 37

38 UCS Manager View of New Ports 38

39 Port Types vs. FI Operating Mode (Green Means Valid in Mode of Operation) 39

40 Hybrid Topology with Direct-Attach and SAN SAN Fabric Storage Arrays Fibre Channel Direct Attach Fabric A Core Fabric B Ethernet Unified I/O FC Storage FCoE Storage FCoE SAN Edge A SAN Edge B Security via Zoneset Merge UCS 6100 UCS 6100 AND Security via LUN Masking LUN Masking Always Used to Some Extent UCS B-Series 40

41 Unsupported Storage Topologies in UCS As of June 2012 Direct connect without zoning (no upstream MDS/N5K) Multi-Hop FCoE or FCoE northbound on Ethernet Uplinks 6100 to N5K for FC to FCoE bridging is still valid with 1.4 in NPV mode FC connections between the two Fabric Interconnects running in FC switch mode (ISL) Connecting any other L2 based object off of the Appliance Ports Untested, unsupported until further notice 41

42 How to Place FI into FC Switching Mode This operation results in both FIs going into reboot cycles which takes 15 min or so, system wide downtime, by design When FC switch mode is turned on, all the FC ports come up in TE mode 42

43 Configuring an FC Storage Port To connect an FC storage device directly into one of the 6100 s FC port, the user must configure the port as an FC storage port The VSAN is configured under the Storage Cloud object Internally, the port is configured as follows: As a F_Port As an access port The speed is kept as auto The user is also allowed to select a named VSAN for that port. 43

44 Configuring an FC Storage Port (GUI) 44

45 Configuring a VSAN on an FC Port (GUI) 45

46 Configuring an FCoE Storage Port (GUI) 46

47 Configuring an FCoE Storage Port (Cont.) Since the Ethernet port is configured as trunk, a native VLAN must be configured on that port. The FCoE VLAN ID can not be the same as the native VLAN ID User is not requested to provide a native VLAN value. An arbitrary VLAN (4048) was chosen and is always used as the native VLAN for FCoE storage ports unless changed 47

48 FCoE Port Must Be Assigned to a VSAN 48

49 IP-based Storage Appliance Ports and iscsi

50 UCS Manager Appliance Ports What is an Ethernet Appliance A specialized device for use on a Ethernet network, for example Network Attached Storage, iscsi, security appliances, Nexus 1010 What qualifies to be an appliance An Appliance is a specialized external host, does not run STP (today only NetApp and EMC IP storage devices qualified) Purpose of Appliance Port Connect Ethernet appliances only! Do Not to use this port type for switch connectivity to avoid traffic loops 50

51 Appliance Ports How to Configure 51

52 Appliance Port Exposed Settings QoS per port settings, normal UCS QoS constructs Manual (static) pinning using pin groups for border port selection Select which VLANs can traverse this port Optionally specify the destination MAC address of the filer. Some Filers do not broadcast their MAC address 52

53 VLANs and Appliance Ports Similar to VSAN concept, there are two scopes Traditional, LAN Cloud Appliance Cloud with scope restricted to appliance ports and associated VLANs Use the same VLAN ID in both scopes 53

54 Appliance Ports Have Uplink Ports Appliance ports like server ports have an uplink or border port assigned either via static or dynamic pinning Loss of last uplink port will result in the appliance port being taken down in UCS Same behavior as current network control policy 54

55 Storage Controller Ethernet Port High Availability Both NetApp and EMC have similar technologies for aggregating ports on their controllers and providing failure handling. An In-depth comparison of these technologies is beyond the scope of this document Storage Vendor documentation should be consulted for details of their feature set It is important to understand the core behavior of these technologies as they relate to UCS Appliance Ports in failure cases For additional information: 55

56 Storage Vendor Ethernet Port Aggregation and Failover Terminology EMC Fail Safe Network (FSN), layered availability of interfaces UCS needs active/passive Member links can be individual links or consist of port channels Etherchannel is Port channel but ON only Link Aggregation is LACP based NetApp Multi-Level Virtual Interface (VIF) interface groups UCS needs active/passive Member links can be individual links or consist of port channels Multi-mode Static is Port channel but ON only Multi-mode dynamic is LACP based. 56

57 iscsi Boot 1.3: Not supported 1.4: Supported via manual configuration of Adapter Broadcom Mezzanine Card Only Not productized to any extent by UCSM Not stateless, user configures manually, and UCS Manager is totally unaware of changes to mezzanine card configuration. 2.0 (June/July 2011) Fully Supported in UCS Manager Fully productized by UCS Manager boot polices Support for Broadcom and Cisco M81KR VIC 57

58 iscsi Feature Overview Primary purpose is to support booting via iscsi iscsi Hardware Offload is not a requirement to support booting, only supporting iscsi Boot Firmware Table (ibft) in the option ROM First release that UCS manager represents an iscsi device in the model and GUI New object called an iscsi vnic is created as a child object to the standard parent vnic New pools and policies to support iscsi vnic attributes in the LAN tab 58

59 iscsi Boot Flow Create iscsi vnics Create iscsi boot policy Provide UCSM with iscsi boot information Target ip, iqn Initiator ip/mask/gw, iqn vmedia map the OS and drivers Adapter successfully initializes Install OS and Drivers (if required) 59

60 iscsi and Appliance Port Redundancy Host Multi-pathing drivers are used in lieu of link aggregation network technology MS does not support using s/w iscsi and port channels for iscsi failover Best practice is to use MPIO drivers Failure semantics look like FC in this regard 60

61 Storage Vendor Support UCS 1.4 Direct Connect only support EMC and NetApp for all topologies (FC, FCoE, NAS) We may add more vendors as a function of time given business case justifications iscsi Boot will only support EMC and NetApp Arrays We may add more vendors as a function of time given business case justifications Please Consult the these resources B_rel2.02.pdf 61

62 Useful Troubleshooting and Diagnostic Commands

63 Troubleshooting (Inconsistent Interface) What if a port is configured as a FC/FCoE storage port but the FC mode is end-host? An error message pops up in the GUI (See next slide) The interface is created but its configstate property is set to Inconsistent. The admin state of the associated physical port is also disabled. The interface gets out of this state automatically (its configstate is changed to Applied ) if the mode is changed to FC switch. 63

64 Troubleshooting (Inconsistent Interface) Error message when a storage port is configured in end-host mode: 64

65 FC NPV Mode. Are vhbas Logging in and Where, Which FC Uplink? ucstestfi-a(nxos)# show npv flogi-table Which WWPN In Service Profile Which FC Uplink SERVER EXTERNAL INTERFACE VSAN FCID PORT NAME NODE NAME INTERFACE vfc x01000e 20:00:00:25:b5:01:00:bf 20:00:00:25:b5:0a:00:8f fc2/5 vfc x01000f 20:00:00:25:b5:01:00:df 20:00:00:25:b5:0a:00:8f fc3/5 vfc x01000c 20:00:00:25:b5:01:00:9f 20:00:00:25:b5:0a:00:9f fc2/5 vfc x01000d 20:00:00:25:b5:01:00:af 20:00:00:25:b5:0a:00:9f fc3/5 vfc x :00:00:25:b5:01:00:1f 20:00:00:25:b5:0a:00:7f fc2/5 vfc x :00:00:25:b5:01:00:3f 20:00:00:25:b5:0a:00:7f fc3/5 vfc x :00:00:25:b5:01:00:be 20:00:00:25:b5:0a:00:4f fc2/5 65

66 Useful Troubleshooting CLI in FC Switch Mode 66

67 Check on Zoneset Merge (Hybrid Topology) Checking that the zoning configuration has been merged There is no GUI equivalent to sh zoneset active. You need to run an NXOS CLI: Panther-A(nxos)# show zoneset active vsan 300 zoneset name fabric-a-panther vsan 300 zone name ls1-netapp1-4b vsan 300 pwwn 50:0a:09:83:97:b9:4c:e4 pwwn 20:01:00:25:b5:71:a0:01 zone name ls1-netapp2-4b vsan 300 * fcid 0x [pwwn 50:0a:09:83:87:b9:4c:e4] pwwn 20:01:00:25:b5:71:a0:01 zone name ls2-netapp1-4b vsan 300 pwwn 50:0a:09:83:97:b9:4c:e4 * fcid 0x [pwwn 20:01:00:25:b5:71:a0:02] 67

68 Troubleshooting CLI Zoneset Merge How to verify that switches were merged in the same fabric Principal vs. Local in domain context Panther-A(nxos)# show fcdomain domain-list vsan 300 Number of domains: 3 Domain ID WWN x45(69) 21:2c:00:0d:ec:a3:9c:01 [Principal] 0x17(23) 21:2c:00:0d:ec:d2:ce:01 [Local] 0x7f(127) 21:2c:00:0d:ec:d0:9c:81 68

69 iscsi Boot Troubleshooting M81KR (Palo) Disable quiet boot for your blade models, This makes troubleshooting so much easier If your SP and iscsi config is correct, you will see this during POST Palo Initialization cae-sj-ca1-a# conn adapter 1/8/1 adapter 1/8/1 # connect adapter 1/8/1 (top):1# attach-mcp adapter 1/8/1 (mcp):1# iscsi_get_config vnic iscsi Configuration: vnic_id: 5 link_state: Up Initiator Cfg: initiator_state: ISCSI_INITIATOR_READY initiator_error_code: ISCSI_BOOT_NIC_NO_ERROR vlan: 0 dhcp status: false IQN: eui abcdabcd IP Addr: Subnet Mask: Gateway: Target Cfg: Target Idx: 0 State: ISCSI_TARGET_READY Prev State: ISCSI_TARGET_DISABLED Target Error: ISCSI_TARGET_NO_ERROR IQN:iqn com.netapp:sn IP Addr: Port: 3260 Boot Lun: 0 Ping Stats: Success (9.698ms) Session Info: session_id: 0 host_number: 0 bus_number: 0 target_id: 0 69

70 FC Boot Troubleshooting M81KR (Palo) Using LUNLIST to Troubleshoot Looking Good Assigned Service Policy can see Target LUN on Boot FIELD-TME# connect adapter 3/1/1 adapter 3/1/1 # connect adapter 3/1/1 (top):1# attach-fls adapter 3/1/1 (fls):1# vnic vnic ecpu type state lif fc active fc active 5 adapter 3/1/1 (fls):2# lunlist 7 vnic : 7 lifid: 4 - FLOGI State : flogi est (fc_id 0x050a02) - PLOGI Sessions - WWNN 26:02:00:01:55:35:0f:0e fc_id 0x LUN's configured (SCSI Type, Version, Vendor, Serial No.) LUN ID : 0x (0x0, 0x5, Promise, B2D58130F35E1) - REPORT LUNs Query Response - Nameserver Query Response - WWPN : 26:02:00:01:55:35:0f:0e 70

71 M72KR (E/Q) CNA Considerations Qlogic and Emulex gen2 card, the FCoE ID: cannot be the same as VLAN ID:1. Any vfcs that have their vsan s FCoE ID: 1 is in conflict with VLAN ID:1 they will remain in the DOWN state Solution: Change the default vsan1 s FCoE ID from 1 to 10 (or something else that is not conflict) 71

72 Complete Your Online Session Evaluation Give us your feedback and you could win fabulous prizes. Winners announced daily. Receive 20 Passport points for each session evaluation you complete. Complete your session evaluation online now (open a browser through our wireless network to access our portal) or visit one of the Internet stations throughout the Convention Center. Don t forget to activate your Cisco Live Virtual account for access to all session material, communities, and on-demand and live activities throughout the year. Activate your account at the Cisco booth in the World of Solutions or visit 72

73 Final Thoughts Get hands-on experience with the Walk-in Labs located in World of Solutions, booth 1042 Come see demos of many key solutions and products in the main Cisco booth 2924 Visit after the event for updated PDFs, ondemand session videos, networking, and more! Follow Cisco Live! using social media: Facebook: Twitter: LinkedIn Group: 73

74

UCS Engineering Details for the SAN Administrator

UCS Engineering Details for the SAN Administrator UCS Engineering Details for the SAN Administrator Craig Ashapa 2 First things first: debunking a myth Today (June 2012 UCS 2.02m) there is no FCoE northbound of UCS unless you really really really want

More information

UCS SAN Deployment Models and Best Practices

UCS SAN Deployment Models and Best Practices UCS SAN Deployment Models and Best Practices Craig Ashapa, Technical Marketing Engineer Topics Introduction of Converged Network Adapters (CNAs) CNAs and Port WWNs Considerations UCS Storage Modes of Operation

More information

UCS Technical Deep Dive: Getting to the Heart of the Matter

UCS Technical Deep Dive: Getting to the Heart of the Matter UCS Technical Deep Dive: Getting to the Heart of the Matter Session ID Agenda Introductions UCS Architecture, Innovations, Topology Physical Building Blocks Logical Building Blocks Typical Use Cases (Live

More information

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group 2 UCS Bundled Upgrades Useful for Staging, Labs, and Non Productions This does a very quick fast upgrade

More information

Troubleshooting the Cisco UCS Compute Deployment BRKCOM Cisco and/or its affiliates. All rights reserved.

Troubleshooting the Cisco UCS Compute Deployment BRKCOM Cisco and/or its affiliates. All rights reserved. Troubleshooting the Cisco UCS Compute Deployment 2 Agenda Troubleshooting Cisco UCS Overview Physical Setup Software Setup Configuration Path Tracing Maintenance Key Takeaways Q & A 3 Overview UCS Building

More information

UCS Direct Attached Storage and FC Zoning Configuration Example

UCS Direct Attached Storage and FC Zoning Configuration Example UCS Direct Attached Storage and FC Zoning Configuration Example Document ID: 116082 May 23, 2013 Contents Introduction Prerequisites Requirements Components Used Conventions Background Information UCS

More information

Design and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems

Design and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems Design and Implementations of FCoE for the DataCenter Mike Frase, Cisco Systems SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies

More information

UCS Networking Deep Dive. Neehal Dass - Customer Support Engineer

UCS Networking Deep Dive. Neehal Dass - Customer Support Engineer UCS Networking Deep Dive Neehal Dass - Customer Support Engineer Agenda Chassis Connectivity Server Connectivity Fabric Forwarding M-Series Q & A Cisco Unified Computing System (UCS) Single Point of Management

More information

UCS Fabric Fundamentals

UCS Fabric Fundamentals UCS Fabric Fundamentals Hardware State Abstraction MAC Address NIC Firmware NIC Settings UUID BIOS Firmware BIOS Settings Boot Order BMC Firmware Drive Controller F/W Drive Firmware State abstracted from

More information

FCoE Cookbook for HP Virtual Connect

FCoE Cookbook for HP Virtual Connect Technical whitepaper FCoE Cookbook for HP Virtual Connect Version 4.45 Firmware Enhancements August 2015 Table of contents Change History 6 Purpose 7 Overview 7 Requirements and support 7 Supported Designs

More information

Cisco UCS Local Zoning

Cisco UCS Local Zoning Configuration Guide Cisco UCS Local Zoning Configuration Guide May 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 30 Contents Overview...

More information

UCS Management Architecture Deep Dive

UCS Management Architecture Deep Dive UCS Management Architecture Deep Dive Agenda Introductions UCS Architecture, Innovations, Topology Physical Building Blocks Logical Building Blocks Typical Use Cases (Live UCS Demo) Programmable Infrastructure

More information

Configuring Cisco UCS Server Pools and Policies

Configuring Cisco UCS Server Pools and Policies This chapter contains the following sections: Global Equipment Policies, page 1 UUID Pools, page 3 Server Pools, page 5 Management IP Pool, page 7 Boot Policy, page 8 Local Disk Configuration Policy, page

More information

Windows 2012 NPIV on UCS Configuration Example

Windows 2012 NPIV on UCS Configuration Example Windows 2012 NPIV on UCS Configuration Example Document ID: 116471 Contributed by Felipe de Mello and Marcin Latosiewicz, Cisco TAC Engineers. Jul 21, 2014 Contents Introduction Prerequisites Requirements

More information

Configuring Cisco UCS Server Pools and Policies

Configuring Cisco UCS Server Pools and Policies This chapter contains the following sections: Global Equipment Policies, page 1 UUID Pools, page 4 Server Pools, page 5 Management IP Pool, page 7 Boot Policy, page 8 Local Disk Configuration Policy, page

More information

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Document ID: 116248 Contributed by Jim Hicks and Shelley Bhalla, Cisco TAC Engineers. May 01, 2014 Contents Introduction Prerequisites

More information

"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary

Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary Description Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary v6.0 is a five-day instructor-led course that is designed to help students prepare for the Cisco CCNP Data Center

More information

Configuring Server Boot

Configuring Server Boot This chapter includes the following sections: Boot Policy, page 1 UEFI Boot Mode, page 2 UEFI Secure Boot, page 3 CIMC Secure Boot, page 3 Creating a Boot Policy, page 5 SAN Boot, page 6 iscsi Boot, page

More information

Fibre Channel Zoning

Fibre Channel Zoning Information About, page 1 Support for in Cisco UCS Manager, page 2 Guidelines and recommendations for Cisco UCS Manager-Based, page 4 Configuring, page 4 Creating a VSAN for, page 6 Creating a New Fibre

More information

Cisco UCS Manager Storage Management Guide, Release 3.1

Cisco UCS Manager Storage Management Guide, Release 3.1 First Published: 2016-01-20 Last Modified: 2017-04-27 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387)

More information

CCIE Data Center Written Exam ( ) version 1.0

CCIE Data Center Written Exam ( ) version 1.0 CCIE Data Center Written Exam (350-080) version 1.0 Exam Description: The Cisco CCIE Data Center Written Exam (350-080) version 1.0 is a 2-hour test with 80 110 questions that will validate that a data

More information

LAN Ports and Port Channels

LAN Ports and Port Channels Port Modes, page 2 Port Types, page 2 UCS 6300 Breakout 40 GB Ethernet Ports, page 3 Unified Ports, page 7 Changing Port Modes, page 10 Server Ports, page 16 Uplink Ethernet Ports, page 17 Appliance Ports,

More information

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F. Dell Networking Solutions Engineering March 2012

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F. Dell Networking Solutions Engineering March 2012 Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F Dell Networking Solutions Engineering March 2012 Revisions Date Description Authors March 2012 Rev. Kevin Locklear

More information

CCIE Data Center Lab Exam Version 1.0

CCIE Data Center Lab Exam Version 1.0 CCIE Data Center Lab Exam Version 1.0 CCIE Data Center Sky rocketing Popularity should not come as any surprise As per Cisco Global Cloud index, published in 2012, gave prediction that by 2016 nearly two

More information

Configuring PortChannels

Configuring PortChannels This chapter provides information about PortChannels and how to configure the PortChannels. Finding Feature Information, page 1 Information About PortChannels, page 1 Prerequisites for PortChannels, page

More information

Configuring Server Boot

Configuring Server Boot This chapter includes the following sections: Boot Policy, page 1 UEFI Boot Mode, page 2 UEFI Secure Boot, page 3 CIMC Secure Boot, page 3 Creating a Boot Policy, page 5 SAN Boot, page 8 iscsi Boot, page

More information

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5 Technical Marketing Solutions Guide Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5 Document Revision Date Revision Description (author) 5/16/2014 1. 0 Draft release (mmclaughlin)

More information

CISCO EXAM QUESTIONS & ANSWERS

CISCO EXAM QUESTIONS & ANSWERS CISCO 642-999 EXAM QUESTIONS & ANSWERS Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 32.5 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot CISCO 642-999

More information

Host and storage system rules

Host and storage system rules Host and storage system rules Host and storage system rules are presented in these chapters: Heterogeneous server rules on page 185 MSA storage system rules on page 235 HPE StoreVirtual storage system

More information

UCS SAN Troubleshooting

UCS SAN Troubleshooting UCS SAN Troubleshooting Document ID: 115764 Contributed by Michael Tao, Cisco TAC Engineer. Jan 15, 2013 Contents Introduction Prerequisites Requirements Components Used Conventions Troubleshooting Tips

More information

N-Port Virtualization in the Data Center

N-Port Virtualization in the Data Center N-Port Virtualization in the Data Center What You Will Learn N-Port virtualization is a feature that has growing importance in the data center. This document addresses the design requirements for designing

More information

Next Generation Computing Architectures for Cloud Scale Applications

Next Generation Computing Architectures for Cloud Scale Applications Next Generation Computing Architectures for Cloud Scale Applications Steve McQuerry, CCIE #6108, Manager Technical Marketing #clmel Agenda Introduction Cloud Scale Architectures System Link Technology

More information

SAN Configuration Guide

SAN Configuration Guide ONTAP 9 SAN Configuration Guide November 2017 215-11168_G0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Considerations for iscsi configurations... 5 Ways to configure iscsi

More information

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide Technical white paper vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide Updated: 4/30/2015 Hongjun Ma, HP DCA Table of contents Introduction...

More information

Configuring Cisco Unified FEX Nexus 2348UPQ with Fiber Channel Interfaces

Configuring Cisco Unified FEX Nexus 2348UPQ with Fiber Channel Interfaces Configuring Cisco Unified FEX Nexus 2348UPQ with Fiber Channel Interfaces This chapter provides details about configuring native fiber channels on Cisco Nexus 2348UPQ FEX, and contains the following sections:

More information

CISCO EXAM QUESTIONS & ANSWERS

CISCO EXAM QUESTIONS & ANSWERS CISCO 642-999 EXAM QUESTIONS & ANSWERS Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 32.5 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot CISCO 642-999

More information

UCS Manager Configuration Best Practices (and Quick Start)

UCS Manager Configuration Best Practices (and Quick Start) UCS Manager Configuration Best Practices (and Quick Start) UCS TME White Paper by Jeff Silberman Version 0.85 What You Will Learn The UCS Manager (UCSM) presents a new paradigm for server management. Among

More information

Fibre Channel Networking for the IP Network Engineer and SAN Core Edge Design Best Practices Chad Hintz Technical Solutions Architect BRKVIR-1121

Fibre Channel Networking for the IP Network Engineer and SAN Core Edge Design Best Practices Chad Hintz Technical Solutions Architect BRKVIR-1121 Fibre Channel Networking for the IP Network Engineer and SAN Core Edge Design Best Practices Chad Hintz Technical Solutions Architect BRKVIR-1121 Session BRKVIR-1121 Abstract Fibre Channel Networking for

More information

Traffic Monitoring. Traffic Monitoring

Traffic Monitoring. Traffic Monitoring , page 1 Creating a Session, page 6 Editing an Existing Session, page 7 Activating or Deactivating a Session, page 7 Deleting a Session, page 8 Traffic monitoring copies traffic, from one or more source

More information

HP 6125XLG Blade Switch

HP 6125XLG Blade Switch HP 6125XLG Blade Switch FCoE Configuration Guide Part number: 5998-3726 Software version: Release 2306 Document version: 6W100-20130912 Legal and notice information Copyright 2013 Hewlett-Packard Development

More information

Service Profiles and Templates

Service Profiles and Templates Service Profile Templates, page 1 Service Profiles, page 3 Service Profile Templates Service profile templates enable you to quickly create several service profiles with the same basic parameters, such

More information

ECE Enterprise Storage Architecture. Fall 2016

ECE Enterprise Storage Architecture. Fall 2016 ECE590-03 Enterprise Storage Architecture Fall 2016 Storage Area Network (SAN) Tyler Bletsch Duke University Adapted from the course Information Storage and Management v2 (module 5-6), published by EMC

More information

Large SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors

Large SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors White Paper Large SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors What You Will Learn As SANs continue to grow in size, many factors need to be considered to help scale

More information

Overview of Cisco Unified Computing System

Overview of Cisco Unified Computing System Overview of Cisco Unified Computing System This chapter includes the following sections: About Cisco Unified Computing System, page 1 Unified Fabric, page 2 Server Architecture and Connectivity, page 4

More information

Question No : 3 Which is the maximum number of active zone sets on Cisco MDS 9500 Series Fibre Channel Switches?

Question No : 3 Which is the maximum number of active zone sets on Cisco MDS 9500 Series Fibre Channel Switches? Volume: 182 Questions Question No : 1 A network architecture team is looking for a technology on Cisco Nexus switches that significantly simplifies extending Layer 2 applications across distributed data

More information

Global Pools. Server Pools. Creating a Server Pool. This chapter includes the following sections:

Global Pools. Server Pools. Creating a Server Pool. This chapter includes the following sections: This chapter includes the following sections: Server Pools, page 1 IP Pools, page 3 IQN Pools, page 4 UUID Suffix Pools, page 6 MAC Pools, page 7 WWN Pools, page 9 Server Pools A server pool contains a

More information

Evolution with End-to-End Data Center Virtualization

Evolution with End-to-End Data Center Virtualization Evolution with End-to-End Data Center Virtualization Yves Louis DC Virtualisation Technical Solution Architect Agenda Data Center Virtualization Overview Front-End Data Center Virtualization Core Layer

More information

Jake Howering. Director, Product Management

Jake Howering. Director, Product Management Jake Howering Director, Product Management Solution and Technical Leadership Keys The Market, Position and Message Extreme Integration and Technology 2 Market Opportunity for Converged Infrastructure The

More information

Cisco MDS 9000 Family Blade Switch Solutions Guide

Cisco MDS 9000 Family Blade Switch Solutions Guide . Solutions Guide Cisco MDS 9000 Family Blade Switch Solutions Guide Introduction This document provides design and configuration guidance for administrators implementing large-scale blade server deployments

More information

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect Vblock Architecture Andrew Smallridge DC Technology Solutions Architect asmallri@cisco.com Vblock Design Governance It s an architecture! Requirements: Pretested Fully Integrated Ready to Go Ready to Grow

More information

Reference Architecture. DataStream. UCS Direct Connect. For DataStream OS 2.6 or later Document # NA Version 1.08 April

Reference Architecture. DataStream. UCS Direct Connect. For DataStream OS 2.6 or later Document # NA Version 1.08 April DataStream For DataStream OS 2.6 or later Document # 310-0026NA Version 1.08 April 2017 www.cohodata.com Abstract This reference architecture describes how to connect DataStream switches to Cisco Unified

More information

Virtual Networks: For Storage and Data

Virtual Networks: For Storage and Data Virtual Networks: For Storage and Data or Untangling the Virtual Server Spaghetti Pile Howard Marks Chief Scientist hmarks@deepstorage.net Our Agenda Today s Virtual Server I/O problem Why Bandwidth alone

More information

Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets

Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets CLI Config Sheets Dell Networking Engineering November 2013 A Dell Deployment and Configuration Guide

More information

Designing Cisco Data Center Unified Computing

Designing Cisco Data Center Unified Computing Designing Cisco Data Center Unified Computing Number: 642-998 Passing Score: 800 Time Limit: 120 min File Version: 1.1 http://www.gratisexam.com/ Sections 1. Drag and Drop 2. Questions 3. Hot Spot CISCO

More information

Citrix XenServer with Dell SC Series Storage Configuration and Deployment

Citrix XenServer with Dell SC Series Storage Configuration and Deployment Citrix XenServer with Dell SC Series Storage Configuration and Deployment Dell Storage Engineering January 2017 A Dell EMC Deployment and Configuration Guide Revisions Date January 2016 Description Initial

More information

UCS Firmware Management Architecture

UCS Firmware Management Architecture UCS Firmware Management Architecture 2 Legal Disclaimer Many products and features described herein remain in varying stages of development and will be offered on a when-and-ifavailable basis. This roadmap

More information

Oracle Database Consolidation on FlashStack

Oracle Database Consolidation on FlashStack White Paper Oracle Database Consolidation on FlashStack with VMware 2017 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 1 of 18 Contents Executive Summary Introduction

More information

Cisco UCS and NetApp Solution for Oracle Real Application Clusters (RAC)

Cisco UCS and NetApp Solution for Oracle Real Application Clusters (RAC) Cisco UCS and NetApp Solution for Oracle Real Application Clusters (RAC) Last Updated: May 18, 2011 Building Architectures to Solve Business Problems 2 Cisco Validated Design About the Authors About the

More information

Dell Networking MXL / PowerEdge I/O Aggregator with Cisco Nexus 5000 series NPV mode and Cisco MDS 9100 fabric switch Config Sheets

Dell Networking MXL / PowerEdge I/O Aggregator with Cisco Nexus 5000 series NPV mode and Cisco MDS 9100 fabric switch Config Sheets Dell Networking MXL / PowerEdge I/O Aggregator with Cisco Nexus 5000 series NPV mode and Cisco MDS 9100 fabric switch Config Sheets CLI Config Sheets Dell Networking Engineering November 2013 A Dell Deployment

More information

Expert Reference Series of White Papers. Cisco UCS B Series Uplink Strategies

Expert Reference Series of White Papers. Cisco UCS B Series Uplink Strategies Expert Reference Series of White Papers Cisco UCS B Series Uplink Strategies 1-800-COURSES www.globalknowledge.com Cisco UCS B Series Uplink Strategies Chris Olsen, Global Knowledge Instructor, Author,

More information

UCS Nirvana. Lee Burleson Network and Systems Engineer Iowa National Guard. Cisco ARNG Training Event March 2011

UCS Nirvana. Lee Burleson Network and Systems Engineer Iowa National Guard. Cisco ARNG Training Event March 2011 UCS Nirvana I A N G S JOURNEY FROM LEGACY BLADE S E R V E R S T O C I S C O U N I F I E D C O M P U T I N G S Y S T E M, W I T H N O ( N O T I C E A B L E ) V M W A R E D O W N T I M E Lee Burleson Network

More information

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES I. Executive Summary Superior Court of California, County of Orange (Court) is in the process of conducting a large enterprise hardware refresh. This

More information

PowerEdge FX2 - Upgrading from 10GbE Pass-through Modules to FN410S I/O Modules

PowerEdge FX2 - Upgrading from 10GbE Pass-through Modules to FN410S I/O Modules PowerEdge FX - Upgrading from 0GbE Pass-through Modules to FN40S I/O Modules Dell Networking Solutions Engineering June 06 A Dell EMC Deployment and Configuration Guide Revisions Date Revision Description

More information

FC Cookbook for HP Virtual Connect

FC Cookbook for HP Virtual Connect Technical white paper FC Cookbook for HP Virtual Connect Version 4.45 Firmware Enhancements January 206 Table of contents Change History 7 Abstract 8 Considerations and concepts 9 VC SAN module descriptions

More information

Fibre Channel and iscsi Configuration Guide for the Data ONTAP 8.0 Release Family

Fibre Channel and iscsi Configuration Guide for the Data ONTAP 8.0 Release Family IBM System Storage N series Fibre Channel and iscsi Configuration Guide for the Data ONTAP 8.0 Release Family GA32-0783-03 Table of Contents 3 Contents Preface... 7 Supported features... 7 Websites...

More information

Cisco UCS Director UCS Central Management Guide, Release 6.5

Cisco UCS Director UCS Central Management Guide, Release 6.5 First Published: 2017-07-11 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 THE

More information

Implementing Cisco Data Center Infrastructure v6.0 (DCII)

Implementing Cisco Data Center Infrastructure v6.0 (DCII) Implementing Cisco Data Center Infrastructure v6.0 (DCII) COURSE OVERVIEW: Implementing Cisco Data Center Infrastructure (DCII) v6.0 is a five-day instructor-led course that is designed to help students

More information

F port channel trunk from MDS 9148 (NPV) to MDS 9509 (NPIV) Configuration Example

F port channel trunk from MDS 9148 (NPV) to MDS 9509 (NPIV) Configuration Example F port channel trunk from MDS 9148 (NPV) to MDS 9509 (NPIV) Configuration Example Document ID: 117781 Contributed by Edward Mazurek, Cisco TAC Engineer. Sep 05, 2014 Contents Introduction Prerequisites

More information

Cisco Nexus B22HP. Design and Deployment Guide. September, For further information, questions and comments please contact

Cisco Nexus B22HP. Design and Deployment Guide. September, For further information, questions and comments please contact Design and Deployment Guide Cisco Nexus B22HP Design and Deployment Guide September, 2011 For further information, questions and comments please contact ccbu-pricing@cisco.com 2011 Cisco and/or its affiliates.

More information

HPE Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.60

HPE Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.60 HPE Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.60 Abstract This document contains setup, installation, and configuration information for HPE Virtual Connect. This document

More information

Configuring Virtual Port Channels

Configuring Virtual Port Channels Configuring Virtual Port Channels This chapter describes how to configure virtual port channels (vpcs) on Cisco Nexus 5000 Series switches. It contains the following sections: Information About vpcs, page

More information

STORAGE CONSOLIDATION WITH IP STORAGE. David Dale, NetApp

STORAGE CONSOLIDATION WITH IP STORAGE. David Dale, NetApp STORAGE CONSOLIDATION WITH IP STORAGE David Dale, NetApp SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies and individuals may use this material in

More information

Deployment of VMware Infrastructure 3 on Dell PowerEdge Blade Servers

Deployment of VMware Infrastructure 3 on Dell PowerEdge Blade Servers Deployment of VMware Infrastructure 3 on Dell PowerEdge Blade Servers The purpose of this document is to provide best practices for deploying VMware Infrastructure 3.x on Dell PowerEdge Blade Servers.

More information

Data Center 3.0 Technology Evolution. Session ID 20PT

Data Center 3.0 Technology Evolution. Session ID 20PT Data Center 3.0 Technology Evolution Session ID 20PT Session Goal The focus of this seminar is on the latest technologies some of which can already be used in today's deployments and some that will become

More information

Configuring and Managing Zones

Configuring and Managing Zones Send documentation comments to mdsfeedback-doc@cisco.com CHAPTER 30 Zoning enables you to set up access control between storage devices or user groups. If you have administrator privileges in your fabric,

More information

Configuring the Fibre Channel Gateway

Configuring the Fibre Channel Gateway CHAPTER 6 This chapter describes Fibre Channel gateway configuration and includes the following sections: Before You Begin, page 6-1 Administering the Fibre Channel Gateway, page 6-1 Pre-configuration

More information

USING ISCSI AND VERITAS BACKUP EXEC 9.0 FOR WINDOWS SERVERS BENEFITS AND TEST CONFIGURATION

USING ISCSI AND VERITAS BACKUP EXEC 9.0 FOR WINDOWS SERVERS BENEFITS AND TEST CONFIGURATION WHITE PAPER Maximize Storage Networks with iscsi USING ISCSI AND VERITAS BACKUP EXEC 9.0 FOR WINDOWS SERVERS BENEFITS AND TEST CONFIGURATION For use with Windows 2000 VERITAS Software Corporation 03/05/2003

More information

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode)

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode) Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode) Dell Networking Solutions Engineering July 2011 A Dell EMC Deployment and Configuration Guide Revisions Date Description

More information

MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1)

MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) 5 CHAPTER MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) This chapter describes how to set up a basic dual-core topology with an MDS 9000 switch configured for interop mode 1 and a McData

More information

HP StorageWorks Fabric OS 6.1.2_cee1 release notes

HP StorageWorks Fabric OS 6.1.2_cee1 release notes HP StorageWorks Fabric OS 6.1.2_cee1 release notes Part number: 5697-0045 First edition: June 2009 Legal and notice information Copyright 2009 Hewlett-Packard Development Company, L.P. Copyright 2009 Brocade

More information

UCS C Series Rack Servers VIC Connectivity Options

UCS C Series Rack Servers VIC Connectivity Options UCS C Series Rack Servers VIC Connectivity Options Document ID: 117637 Contributed by Shankar Prasath, Cisco TAC Engineer. Apr 25, 2014 Contents Introduction Prerequisites Requirements Components Used

More information

Configuring and Managing Zones

Configuring and Managing Zones CHAPTER 19 Zoning enables you to set up access control between storage devices or user groups. If you have administrator privileges in your fabric, you can create zones to increase network security and

More information

Dell Networking FC Flex IOM: Deployment of FCoE with Dell FC Flex IOM, Brocade FC switches and Dell Compellent Storage Array

Dell Networking FC Flex IOM: Deployment of FCoE with Dell FC Flex IOM, Brocade FC switches and Dell Compellent Storage Array Dell Networking FC Flex IOM: Deployment of FCoE with Dell FC Flex IOM, Brocade FC switches and Dell Compellent Storage Array Dell Networking Solutions Engineering January 2014 Revisions Date Version Description

More information

Compute and Storage Implementation

Compute and Storage Implementation 2 CHAPTER The Virtualized Multiservice Data Center (VMDC) 2.3 solution uses modular blocks for Compute and Storage, generically referred to as Integrated Compute and Storage (ICS) stacks. A number of these

More information

Cisco UCS-Mini with B200 M4 Blade Servers High Capacity/High Performance Citrix Virtual Desktop and App Solutions

Cisco UCS-Mini with B200 M4 Blade Servers High Capacity/High Performance Citrix Virtual Desktop and App Solutions In Collaboration with Intel May 2015 Cisco UCS-Mini with B200 M4 Blade Servers High Capacity/High Performance Citrix Virtual Desktop and App Solutions Presenters: Frank Anderson Desktop Virtualization

More information

FlashStack Virtual Server Infrastructure Deployment Guide: Cisco PowerTool Addendum

FlashStack Virtual Server Infrastructure Deployment Guide: Cisco PowerTool Addendum White Paper FlashStack Virtual Server Infrastructure Deployment Guide: Cisco PowerTool Addendum February 2017 2017 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page

More information

Oracle E-Business Suite R12 on Cisco UCS with EMC VNX 5500

Oracle E-Business Suite R12 on Cisco UCS with EMC VNX 5500 White Paper Oracle E-Business Suite R12 on Cisco UCS with EMC VNX 5500 Contents Introduction... 3 Leadership from Cisco... 3 Introducing Cisco UCS... 3 Overview of Cisco UCS... 4 Cisco Nexus 5548UP Switch...

More information

VersaStack Solution for Data Protection with an Integrated IBM Tape Library

VersaStack Solution for Data Protection with an Integrated IBM Tape Library VersaStack Solution for Data Protection with an Integrated IBM Tape Library This document describes how to configure a VersaStack data protection solution using the Cisco Unified Computing System (Cisco

More information

UCS with VMware ESXi End to End Jumbo MTU Configuration Example

UCS with VMware ESXi End to End Jumbo MTU Configuration Example UCS with VMware ESXi End to End Jumbo MTU Configuration Example Document ID: 117601 Contributed by Vishal Mehta, Cisco TAC Engineer. Apr 09, 2014 Contents Introduction Prerequisites Requirements Components

More information

Configuring and Managing Virtual Storage

Configuring and Managing Virtual Storage Configuring and Managing Virtual Storage Module 6 You Are Here Course Introduction Introduction to Virtualization Creating Virtual Machines VMware vcenter Server Configuring and Managing Virtual Networks

More information

Brocade 20-port 8Gb SAN Switch Modules for BladeCenter

Brocade 20-port 8Gb SAN Switch Modules for BladeCenter Brocade 20-port 8Gb SAN Switch Modules for BladeCenter Product Guide The Brocade Enterprise 20-port, 20-port, and 10-port 8 Gb SAN Switch Modules for BladeCenter deliver embedded Fibre Channel switching

More information

On-Site 911 Notification Using Cisco Unified Communications BRKUCC-2012

On-Site 911 Notification Using Cisco Unified Communications BRKUCC-2012 On-Site 911 Notification Using Cisco Unified Communications Session Objective This session will illustrate different methods by which an enterprise can enhance the emergency call handling At the end of

More information

HPE Smart SAN for 3PAR 2.0 User Guide

HPE Smart SAN for 3PAR 2.0 User Guide HPE Smart SAN for 3PAR 2.0 User Guide Abstract This user guide provides information about configuring and using HPE Smart SAN for 3PAR. HPE Smart SAN for 3PAR is a target driven orchestration that provides

More information

Service Oriented Virtual DC Design

Service Oriented Virtual DC Design Dubrovnik, Croatia, South East Europe 20-22 May, 2013 Service Oriented Virtual DC Design Višnja Milovanović Consulting Systems Engineer Data Center & Virtualization 2011 2012 Cisco and/or its affiliates.

More information

Dell EMC Storage Compatibility Matrix for SC, PS and FS Series Arrays

Dell EMC Storage Compatibility Matrix for SC, PS and FS Series Arrays Dell EMC Storage Compatibility Matrix for SC, PS and FS Series Arrays Dell EMC Midrange Storage November, 2017 A Dell EMC Deployment and Configuration Guide The information in this publication is provided

More information

Cisco UCS and Cisco MDS 9000 Family: Better Together

Cisco UCS and Cisco MDS 9000 Family: Better Together White Paper Cisco UCS and Cisco MDS 9000 Family: Better Together What You Will Learn The Cisco Unified Computing System (Cisco UCS ) brings unique capabilities that help scale and simplify x86 server deployments.

More information

You can monitor or use SPAN on port channels only for ingress traffic.

You can monitor or use SPAN on port channels only for ingress traffic. This chapter includes the following sections: Traffic Monitoring, page 1 Guidelines and Recommendations for Traffic Monitoring, page 2 Creating an Ethernet Traffic Monitoring Session, page 3 Creating a

More information

SwitchX Virtual Protocol Interconnect (VPI) Switch Architecture

SwitchX Virtual Protocol Interconnect (VPI) Switch Architecture SwitchX Virtual Protocol Interconnect (VPI) Switch Architecture 2012 MELLANOX TECHNOLOGIES 1 SwitchX - Virtual Protocol Interconnect Solutions Server / Compute Switch / Gateway Virtual Protocol Interconnect

More information

Overview. Cisco UCS Manager User Documentation

Overview. Cisco UCS Manager User Documentation Cisco UCS Manager User Documentation, page 1 Infrastructure Management Guide, page 2 Cisco Unified Computing System, page 3 Cisco UCS Building Blocks and Connectivity, page 5 Cisco UCS Manager User Documentation

More information

FIBRE CHANNEL OVER ETHERNET

FIBRE CHANNEL OVER ETHERNET FIBRE CHANNEL OVER ETHERNET A Review of FCoE Today Abstract Fibre Channel over Ethernet (FcoE) is a storage networking option, based on industry standards. This white paper provides an overview of FCoE,

More information