2 What is Fluke Networks, Inc. today? A stand-alone company set apart from Fluke Corporation in May, 2000, to create an even more tightly aligned, customerneeds driven organization ~ $200M in annual revenues Over 500 associates worldwide Combines the best of Fluke s heritage for quality and reliability with network knowhow and a strong entrepreneurial spirit
3 What we provide Enterprise Networks Remote Enterprise Office Networks: Performance Analysis Router Monitoring & Troubleshooting Reporting & Documentation Moves, Adds, & Changes OSP/Telecom OSP/Telecom: Internet /Telephony Reporting Network Local Loop Recovery Documentation & DSL Qualification Troubleshooting Router House Switched Workgroup Servers Copper & Fiber Structured Cabling: Certification Documentation & Reporting Inspection Troubleshooting Shared Workgroup House House Copper and Fiber Structured Cabling House House
4 48 Countries 220 Sales Professionals 1800 Distribution Outlets 50% of our sales come from outside the US 75% of 2001 revenue was generated by new products introduced in 2000 and 2001 Profitable and Growing
5 What Does Fluke Networks Do? We deliver What is that supposed to mean?
6 We offer more ways to look at your network: Hardware Software Physical Application LAN WAN Portable Distributed
7
8
9 568-A Has Changed to 568-B 568-B.1 B.1 General Reqmts 568-A ANSI/TIA/EIA 568-A-1995 = ANSI/TIA/EIA 568-B-2001 = 568-B.2 B.2 Copper 568-B.3 B.3 Fiber
10 What s going away? TIA/EIA TSB67 TIA/EIA TSB72 TIA/EIA TSB75 TIA/EIA TSB95 ANSI/TIA/EIA568A1 ANSI/TIA/EIA568A2 ANSI/TIA/EIA568A3 ANSI/TIA/EIA568A4 ANSI/TIA/EIA568A5 TIA/EIA/IS B.1 B.1 General Reqmts 568-B.2 B.2 Copper 568-B.3 B.3 Fiber
11 TIA adopts the Permanent Link TIA harmonizes with ISO The revised TIA standards no longer specify Basic Link
12 Channel End Link Definition: Channel Two transitions at each end Channel End USER S PATCH CORD PATCH PANEL CP HORIZONTAL CABLE Telecom Outlet USER S PATCH CORD FLOOR DISTRIBUTOR CP: Consolidation Point WORK AREA
13 Link End Link Definition: Basic Link One transition at each end Tester patch cables max. 2 m long PATCH PANEL Telecom Outlet Link End TESTER PATCH CORD FLOOR DISTRIBUTOR HORIZONTAL CABLE TESTER PATCH CORD WORK AREA
14 We used to test the Basic Link The Basic Link starts and ends at the tester itself, and it includes the adapter cords Includes Tester Adapter Cords Basic Link Patch Panel Telecommunication Room 90 meter max Outlet Work Area
15 But the Basic Link is obsolete Per TIA/EIA-568-B, the Permanent Link model replaces the Basic Link model Includes Tester Adapter Cords Basic Link Patch Panel Telecommunication Room 90 meter max Outlet Work Area
16 Basic Link Weaknesses Developing new Cat 5e specifications revealed some new challenges Return Loss became a critical parameter that had not been considered before Stranded UTP used in patch cables (and cable tester cords) was found to be very unstable and major cause of poor Return Loss performance. The Basic Link definition included 4 meters of cable tester cords in the performance limits, test methods, and test results!
17 Link Definition: Permanent Link Patch Panel Test results do not include contributions by the tester patch cables Link End CP Link End Telecom Outlet TESTER PATCH CORD FLOOR DISTRIBUTOR HORIZONTAL CABLE CP: Consolidation Point TESTER PATCH CORD WORK AREA
18 What is a permanent link? The fixed cabling in the walls the permanent part of the building infrastructure The link model to be used for testing the fixed portion of a cabling installation This excludes users patch cables and equipment cords This excludes tester adapter cords, too
19 A detailed look at the Permanent Link The Permanent Link is the permanent cabling, and it does not include the adapter cords Does NOT include Tester Adapter Cords Permanent Link Patch Panel Telecommunication Room Consolidation Point (optional) Outlet Work Area
20 The purpose of field test Accurately characterize the fixed portion of the data cabling installation upon completion of the installation Network equipment, patch cables and equipment cables are changed many times during the life span of the fixed portion of the cabling (the infrastructure) Provide guarantee that the Channel meets the network s requirements by connecting good patch cords
21 Cat 5e and Cat 6 test problems There are two measured parameters that present serious accuracy problems that are very difficult for testers to correct Measured Wire map Propagation delay Attenuation NEXT (pair-to-pair) FEXT (pair-to-pair) Return Loss Calculated Length, Delay Skew PSNEXT, ACR, PSACR ELFEXT, PSELFEXT
22 Return Loss is a major challenge Measured separately from both ends, Return Loss is a measure of reflected signal (undesirable) The Return Loss that should be measured, which is attenuated by the link, is within the link: Permanent Link (Reflections occur wherever there are changes in impedance, such as bends, twist variations, terminations, connectors, etc.)
23 Return Loss is a major challenge Measured separately from both ends, Return Loss is a measure of reflected signal (undesirable) The Return Loss that should be measured, which is attenuated by the link, is within the link: Permanent Link But Return Loss in the tester s adapter cords adds measurement error and must be eliminated and there is only one solution the DSP-LIA101S!
24 The impact of twisted-pair adapters Twisted-pair adapters degrade with handling and use in the field Return Loss margin can drop significantly Permanent links that are good but close to the limit can produce false failures Permanent links that are very good can still yield poor test results because twisted-pair tester adapters contribute to Return Loss! Use the DSP-LIA101S to PASS!
25 Return Loss of twisted-pair adapter Impact of handling and aging - Sample Return Loss (db) CAT6 BL BL +12dB Initial 50 cyc 100 cyc 200 cyc Cable Lim 26-12*LOG(f/100) 21-7*LOG(f/20) BL + 12 db Basic Link Frequency (MHz)
26 Correction for adapter cable Test parameter Attenuation Length Propagation delay NEXT & FEXT Return Loss Effect of tester patch cable Stable Corrected Stable Corrected High Quality patch cord (PiMF or SSTP) has negligible crosstalk Unpredictable!!
27 Requirements for accurate Return Loss The tester s permanent link interface cable itself must have very good return loss characteristics 1. Impedance very close to 100 Ω 2. Very good Return Loss performance 3. Stability: very stable impedance characteristic over time (after repeated uncoiling, testing, and recoiling to pack with tester)
28 What is necessary for return loss Measurement? Direction of measurement Cable with stable properties! Permanent link starts This requires a high quality interconnect! Calibrate here! Permanent link ends Use cable with best possible return loss! Impact from return loss is reduced by the round trip insertion loss (attenuation)!
29 What is necessary for return loss Measurement? Measure in opposite direction! Use cable with best possible return loss! Permanent link ends This requires a high quality interconnect! Calibrate here! Cable w/ stable properties! Permanent link starts Direction of measurement
30 DSP-LIA101S Permanent Link Interface Adapter A rugged, highperformance link interface adapter for the DSP-4000 Series testers Very accurately measures the performance of an installed twisted-pair cabling system A major improvement! N E T W O R K S U P E R V I S I O N
31 Cat 6 Return Loss Accuracy Level III Less Accurate More Accurate Measurement Accuracy in db Permanent Link Level III per Standard (with adapter attached to tester) This is what tester manufacturers try to meet! Tester Baseline Level III per Standard (no adapter attached) But how accurate is the DSP-LIA101S Permanent Link Adapter? Frequency in MHz
32 Cat 6 Return Loss Accuracy Level III Less Accurate More Accurate Measurement Accuracy in db Permanent Link Level III per Standard (with adapter attached to tester) This is what tester manufacturers try to meet! Tester Baseline Level III per Standard (no adapter attached) DSP-4000 Series with DSP-LIA101S Out-of-the-box, our Permanent Link Adapter solution is far more accurate than any other tester with a twisted-pair adapter! Frequency in MHz
33 But you can do better yet... Field Calibration of the Permanent Link Interface Adapter
34 A simple calibration of the adapter cable Apply a technique used in the laboratory: one-port calibration The Personality Module is simply replaced with Calibration Artifacts : Open, Short, and 100 Ω Load SHORT OPEN LOAD DSP-PLCAL Calibration Artifacts This is a Network Analyzer Calibration.
35 Overview of adapter calibration process Main and remote units are originally calibrated Calibration for Return Loss can be executed by customer with DSP-PLCAL kit (optional equip.) A highly automated process takes only minutes Cal constants are stored in the adapter Flash EPROM The adapters must be used with the DSP-4X00 with which they have been calibrated Calibrate only twice a year for better-than-new performance...
36 Cat 6 Return Loss Accuracy Level III Less Accurate More Accurate Measurement Accuracy in db Permanent Link Level III per Standard (with adapter attached to tester) This is what tester manufacturers try to meet! Tester Baseline Level III per Standard (no adapter attached) DSP-4000 Series with DSP-LIA101S DSP-4000 Series with DSP-LIA101S AFTER FIELD CAL Frequency in MHz This is exceptional performance!
37 Advantages of DSP-LIA101 with calibration Extend the life of the DSP-LIA101S indefinitely Restore the measurement performance of the adapter to better than new Any aging effect due to coiling and uncoiling is compensated The last adapter you ll ever buy Increase the accuracy of the RL measurement Much lower probability of any false failures More accuracy = more PASS results
38 NEXT Interoperability is a challenge Cat 6 plugs and jacks remain proprietary designs The jack compensates the electrical performance of the plug NEXT performance Vendors have implemented unique combinations to achieve Cat 6 performance for the connection Many combinations from different vendors perform worse than vendor-matched components This is the reason for the many Cat 6 Basic Link Adapters in use
39 The DSP-LIA101S solution for NEXT The Permanent Link Adapter plug is modular The removable 8-pin plug can be replaced with different Personality Modules You need only one adapter set
40 NETWORKSUPERVISION What is in the Personality Module? A small circuit board connecting to leads to the 8pin modular plug. A PROM to identify the probe tip. The location of the reference plane of calibration is as close as practically possible near the plug.
41 Personality Module interoperability matrix NEXT performance is excellent Each Personality Module covers many vendors Other modules are under development Check the website for the latest matrix update!!
42 Advantages of Personality Modules You only need one set of Link Interface Adapters: the DSP-LIA101S The standard module DSP-PM01 delivers Cat 6 performance with at least 10 types of Cat 6 jacks The modules meet all of the requirements for Cat 6 and Cat 5e (and Cat 3) Easy to store and carry A set costs only half as much as a Basic Link Adapter set
43 Standards for field test N E T W O R K S U P E R V I S I O N Level of Performance Applicable Standards Level I and II TIA TSB-67 (*) TIA category 5 Level IIe TIA TSB-95 (*) Level III Cabling System to be tested Minimum Gigabit Ethernet (TIA category 5 with RL, ELFEXT and PSELFEXT) TIA/EIA-568-A-5 TIA Enhanced category 5 TIA/EIA-568-B.2 IEC ISO/IEC Class D TIA/EIA-568-B Addendum 1 TIA category 6 Rev. 1 to IEC ISO/IEC Class E (*) These TSB documents will be obsolete with the approval of TIA-568-B Entries in red are draft specification
44
45
46 DSP-LIA101S Benefits for End-Users Get an accurate picture of performance of the Permanent Link configuration Only the cabling that is part of the infrastructure fixed and permanent. Get assurance that investment in cabling infrastructure will deliver reliable long-term service Add good patch cords and/or equipment cords to obtain high performance channels Certify the cabling installation in perfect compliance with the new industry standard
47 Benefits for Contractors and Installers Carry only one set of tester interface adapters that will last virtually indefinitely Save time and money by measuring NEXT and Return Loss with the accuracy of lab equipment Get more PASS results; reduce false failures If the plug is damaged, replace only a Personality Module Restore the performance to better than new condition with a simple calibration procedure
48 Which tests must be execute?
49 CAT 5e / 6 Cable Certification WALL OUTLET PATCH PANEL HORIZONTAL CABLE Smart Remote WORK AREA DSP-4300 Just Push Test! WIRING CLOSET
50 Autotest Results Indication of overall pass or fail Summary of all tests performed and required by the chosen standard Remember to push SAVE Push the View Result button to review individual tests
51 Unique Digital Test Technology Automated Fault Info Time Domain X-Talk Analyzer If the tests fail Push Fault Info Find the fault and then analyze the fault
52 Test Results Management -- Removable Memory Card Utilizes standard Sandisk MMC s Standard card: 16 Mbytes, 300 complete tests Optional card: 32 Mbytes, 600 complete tests Separate card reader included in package -- Keep the DSP in the field, not the office! Eliminate the need to re-test! Store every measurement value for every applicable test parameter with the DSP
53 Test Results Management -- Cable Manager TM Software CableManager shareware allows you to quickly and easily: Organize Merge (append) Sort up to 5000 Reports Find Edit Export Print Works in Windows 95, 98, NT4.0, and Windows 2000
54 Test Results Management -- Printed Reports DSP Cable Management Software supports several alternatives to provide test results information to your customer: Graphical color report with measured test points over full frequency range (1-350 Mhz) Text format with worst case and worst value data Summary report which provides a list of the cabling links tested and key information N E T W O R K S U P E R V I S I O N
55 Fiber Optic Test Adapters Productivity: Automatic and Fast Test two fibers in a link at two wave-lengths Automatically calculates pass/fail limits based on fiber test standards Provides documented certification of test results
56 Fiber Test Adapters N E T W O R K S U P E R V I S I O N Fiber Application Standard Sources Test Tool 100BaseFX 10 BaseFL LED 850 Multi FDDI LED 1300 DSP-FTA420S mode ATM Token Ring Demand Priority 1000BaseSX (GbE) ATM VCSEL 850nm Fibre Channel (GbFC) DSP-FTA440S Single mode FP Laser 1310nm 1000BaseLX (GbE) Fibre Channel (GbFC) FP Laser 1310nm FP Laser 1550nm NEW! DSP-FTA430S
57 Fiber Optic Test Adapters N E T W O R K S U P E R V I S I O N DSP-FTA440S Green Band VCSEL 850nm 1310nm Laser DSP-FTA430S Yellow Band 1310nm Laser 1550nm Laser DSP-FTA420S Solid Grey 850 nm LED 1300 nm LED
58 N E T W O R K S U P E R V IS IO N We have our eye on the future for you. for more info : maurizio.malinconi@flukenetworks.com Thank you!
Standards Update. by Paul Kish NORDX/CDT
Standards Update by Paul Kish NORDX/CDT Standards overview Category 5e cabling new transmission parameters patch cord return loss Category 6 cabling cable choices backwards compatibility Summary Outline
More informationSECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION
SECTION 17045 TELECOMMUNICATIONS TESTING AND DOCUMENTATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including Facilities Management Design and Construction
More informationCertification for 10G copper cabling
Certification for 10G copper cabling Presented by Eric Lie, Sales Manager 1 Introduction This presentation is intended to provide an overview of the 10GBASE-T requirements for cabling The applicable standards
More informationThe AMP NETCONNECT Category 6 Cabling System
The AMP NETCONNECT Category 6 Cabling System 2 Table of Contents TABLE OF CONTENTS...3 PERSPECTIVE...4 WHY INSTALL NEXT GENERATION CABLING SYSTEMS?...4 MEGAHERTZ VS. MEGABITS...4 PLANNING FOR THE FUTURE...5
More informationEnterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India
Enterprise Network Test Strategies for Network Availability and Performance A Sitaramaiah Director Fluke Networks India 1 Why is Enterprise Network Testing becoming increasingly important? IT is increasingly
More informationQualified Partner Programme QPP. Cat.6 Channel Meassurement Issues Felice Guarna
Qualified Partner Programme QPP Cat.6 Channel Meassurement Issues Felice Guarna Agenda Channel and link definitions Why measure a channel? Patch cord affects on link performance The challenge of channel
More informationChapter 3 Certifying Twisted Pair Cabling
Chapter 3 Certifying Twisted Pair Cabling Setting the Reference The reference procedure sets a baseline for insertion loss, ELFEXT, and dc resistance measurements. Run the tester s reference procedure
More informationThe AMP NETCONNECT Category 6 Cabling System
The AMP NETCONNECT Category 6 Cabling System Table of Contents TABLE OF CONTENTS... 3 PERSPECTIVE... 4 WHY INSTALL NEXT GENERATION CABLING SYSTEMS?... 4 MEGAHERTZ VS. MEGABITS... 4 PLANNING FOR THE FUTURE...
More informationANSI/TIA/EIA-568-B Cabling Standard
73 ANSI/TIA/EIA-568-B Cabling Standard In the mid-1980s, consumers, contractors, vendors, and manufacturers became concerned about the lack of specifications relating to telecommunications cabling. Before
More informationPerformance specification for the Fluke DSP Fluke Corporation
Performance specification for the Fluke Fluke Corporation 1. Summary This document contains the performance specifications in terms of requirements per draft TIA and IEC specifications. Since requirements
More informationCable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment F Cable Certification
General Testing Criteria (Applies to all cable certification testing) 1. RCIT reserves the right to be present during any or all cable testing procedures. The Contractor shall obtain authorization from
More informationWireScope 155 SCOPE. Agilent Wirescope 155 Specs Provided by The Performance Leader in Hand-Held Network Tools
Agilent Wirescope 155 Specs Provided by www.aaatesters.com WireScope 155 Tests installed cabling for compliance with TIA 568A Category 5 and ISO 11801 Class D specifications. Fully implements TIA TSB-67
More informationJamey Calloway, RCDD Product Management Specialist Optical Cable Corporation
Testing and deployment of direct attach and the impact of category 8 Thursday, 10 August 2017, 3:50-4:40 P.M. Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation Overview Traditional
More informationCategory 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope
Category 8 paves the way for IEEE 40GBASE-T David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope Agenda Market need for 40 G over balanced twisted pair cabling Standards ISO/IEC 11801-99-1
More informationCabling Infrastructure
Introduction Ethernet Banking on Structured Cabling Technology Drivers Classification of Cables Fibre-optic cable Cables in building Cabling Infrastructure Cabling systems address the networking requirements
More informationA FLUKE networks DTX 1800 Cable Analyzer és DTX Fiber Modules
A FLUKE networks DTX 1800 Cable Analyzer és DTX Fiber Modules Rövidített leírás és kezelési utasítás The DTX Series CableAnalyzers are rugged, hand-held instruments used to certify, troubleshoot, and document
More informationPsiber Data WireXpert P R O F E S S I O N A L N E T W O R K T E S T I N G & P R O T O C O L A N A L Y S I S
Psiber Data WireXpert Agenda Psiber Data WireXpert Introduction Company Presentation Why Cable Certification? Universal Structured Cabling or The Network Standards The WireXpert Page 2 Psiber Data Company
More informationANSI/TIA-568-C Cat 6A Field Test Specifications
This document has been prepared to aid consultants or engineers in developing contractual specifications covering the certification of Category 6A Permanent Links. It is offered as a general guide. Suitability
More informationAppendix 1 to the R&Mfreenet Warranty Program
Appendix 1 to the R&Mfreenet Warranty Program 1 R&M Certification Process The R&Mfreenet certification process is three pillars: a) Adherence to applicable standards, both for products and installations;
More informationField-testing procedure. LANmark-6
Field-testing procedure LANmark-6 Technical Paper Nexans Cabling Solutions September 2006 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent link testing vs. Channel
More informationWhite paper. Field Testing of Direct Attach Modified Permanent Links. occfiber.com
The dramatic growth of high-bandwidth wireless access points and other IP-enabled devices, such as surveillance cameras and building automation equipment has resulted in the practice of installing direct
More informationISO/IEC 11801: (E)
ISO/IEC 11801:2002-09 (E) Information technology_- Generic cabling for customer premises CONTENTS FOREWORD...10 INTRODUCTION...11 1 Scope...13 2 Normative references...13 3 Definitions, abbreviations and
More informationThe High Cost of a Low-Cost Cable Certification Tester
The High Cost of a Low-Cost Cable Certification Tester Our thanks to Fluke Networks for allowing us to reprint the following article. How much does it cost? That is typically the first question a cabling
More informationANSI/TIA/EIA-568-B Cabling Standard
83 Pair Numbers and Color Coding The conductors in a UTP cable are twisted in pairs and color coded so that each pair of wires can be easily identified and quickly terminated to the appropriate pin on
More informationQualified Partner Programme QPP. Warranty Felice Guarna
Qualified Partner Programme QPP Warranty Felice Guarna Overview Why a warranty? R&M warranties at a glance Prerequisites Product warranty System warranty Application warranty Procedure Summary Warranty
More informationTIA TR-42 Liaison to IEEE
TIA TR-42 Liaison to IEEE Val Rybinski Vice-Chair, TR-42.7 May 2005 Austin, TX Impact of PHY Capabilities Extended frequency characterization required Alien crosstalk limits and test methods required Strategies
More informationLanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance
LanTEK III FiberTEK III Certifier for Copper and Fibre Cabling Proof of Performance LanTEK III FiberTEK III The LanTEK III is an easy to use cable certifier that meets existing TIA and ISO/IEC performance
More informationOpen System Architecture Selecting the Right Cable and Connectivity for Your Application
Open System Architecture Selecting the Right Cable and Connectivity for Your Application Kenneth Cornelison Industry Consultant Wire and Cable Technology Engineering Resources Key Discussion Points TIA
More information[0.057] 5.8 [0.23]
Product Specification 7 March 13 Rev A1 SL Series Jacks, Category 6 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, Category 6 SL Jacks used
More informationLanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance
LanTEK III FiberTEK III Certifier for Copper and Fibre Cabling Proof of Performance LanTEK III FiberTEK III The LanTEK III is an easy to use cable certifier that meets existing TIA and ISO/IEC performance
More informationFrequently Asked Questions (FAQs) Siemon 10G ip Solutions
Frequently Asked Questions (FAQs) Siemon 10G ip Solutions The world of enterprise cabling is evolving rapidly. Emerging, high-bandwidth services and the adoption of higher speed Ethernet standards, like
More informationLANcat System 6 with C5e Performance Module. User Manual Addendum
LANcat System 6 with C5e Performance Module User Manual Addendum Datacom Textron may make improvements or additions to this publication or their products at any time without notice. Datacom Textron shall
More informationField-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4
Field-testing procedure of LANmark-6 10G Cabling System Technical Paper Nexans Cabling Solutions June 2007 - Revision 1.4 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent
More informationTesting Considerations for Beyond 10Gigabit Ethernet. Erin Hallett
Testing Considerations for Beyond 10Gigabit Ethernet Erin Hallett JDSU Agenda Intro Need for Speed Growth of IP traffic Fiber vs. Copper Fiber Tightening requirements Testing considerations and practices
More informationHow new testing standards affect you Singapore, Nov 2009
How new testing standards affect you Singapore, Nov 2009 Adrian Young Sr. Customer Support Engineer In this presentation, we will cover How ANSI/TIA-568-C.2 has consolidated all the different test plugs
More informationLANmark-6 10G LANmark-6 A
Field-testing procedure of LANmark-6 10G LANmark-6 A Cabling System Technical Paper Nexans Cabling Solutions March 2006 - Revision 1.1 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction
More informationNGEAB-T Use Cases. Berlin, Germany February Chris DiMinico MC Communications/Panduit
NGEAB-T Use Cases Berlin, Germany February 2015 Chris DiMinico MC Communications/Panduit cdiminico@ieee.org 1 Scope Next Generation Enterprise Access BASE-T PHY Study Group to define use cases and deployment
More information[0.057] 5.8 [0.23]
Product Specification 7 June 13 Rev B SL Series Jacks, Category 6 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, Category 6 SL Jacks used
More informationThe Cabling Partnership
The author Mike Gilmore, Senior Partner of The Cabling Partnership, is involved at the highest level in UK and European cabling standardisation. Mike is Chairman of the BSI Premises Cabling Experts Panels
More informationDTX CableAnalyzerTM Accessories Guide
NETWORKSUPERVISION DTX CableAnalyzerTM Accessories Guide See how Fluke Networks options and accessories can easily enhance your investment. Smart Remotes Contents Smart Remotes................. 2 DTX 10
More informationThe Impact of Internet of Things on Cable Certification
The Impact of Internet of Things on Cable Certification Softing IT Networks ---Philippe PATINOTE --- Agenda Short introduction Softing IT Networks Brief review on traditional office cabling configurations
More informationDatasheet: CableIQ Qualification Tester - The network tech s vision into cabling bandwidth.
Datasheet: CableIQ Qualification Tester - The network tech s vision into cabling bandwidth. CableIQ, the first cabling bandwidth tester for network technicians As an IT professional, you have a tough balancing
More informationTO THE BID PACKAGE FOR COUNTY OF INYO NETWORK PROJECT. This addendum is being issued to modify portions of the Bid Package for the Project entitled:
ADDENDUM NO. 2 TO THE BID PACKAGE FOR February 6, 2006 This addendum is being issued to modify portions of the Bid Package for the Project entitled: Receipt of this Addendum should be acknowledged by inserting
More informationAMP-TWIST* 6S Series SL Jack
Product Specification 108-93003 16/Mar/2011 Rev E AMP-TWIST* 6S Series SL Jack 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, AMP- TWIST*
More informationREPORT INTERTEK TESTING SERVICES, INC.
REPORT INTERTEK TESTING SERVICES, INC. 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 ORDER NO.: J20042193-406 DATE: March 19, 2001 REPORT NO.: J20042193-004 RENDERED TO: Tyco Electronics 3700 Reidsville Rd.
More informationAdvanced Test Equipment Rentals ATEC (2832) OMNIScanner TM. featuring OMNIFiber TM
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMNIScanner TM featuring OMNIFiber TM the future of network testing OMNIScanner2 TM OMNIScanner LT TM OMNIFiber TM User
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationANSI/TIA-568-C Cat 6 Field Test Specifications
This document has been prepared to aid consultants or engineers in developing contractual specifications covering the certification of Category 6 Permanent Links. It is offered as a general guide. Suitability
More informationApplication & Electrical Performance. Category 5e Silver Solution
Application & Electrical Performance Category 5e Silver Solution CONTENTS Page No. Scope 3 Executive Summary 4 Transmission Test Method and Results 5-7 Electrical Test Method and Results 8-11 Definitions
More informationSYSTIMAX SCS Power Sum Solution
SYSTIMAX SCS Power Sum Solution Superior Performance for CAT 5 Networks Realize the Full Potential of Your CAT 5 Network... You ve made a significant investment in your data network. Every component meets
More informationThe following pages contain a guide for the installation
INDEX The goal of this section is to illustrate how Siemon Company products can be used to support some of the most popular and emerging networks on the market. Section Contents 100Base-T....................................
More informationThe Impact of Internet of Things (IoT) on Cable Certification
The Impact of Internet of Things (IoT) on Cable Certification Simon Harrison General Manager Softing Singapore Pte Ltd November 2017 Agenda Review of traditional structured cabling configurations Special
More informationFamily of Cords SYSTIMAX. Structured Cabling Systems. Quality Stranded and Solid Cords That Connect Data and Voice Circuits
SYSTIMAX Structured Cabling Systems Family of Cords Quality Stranded and Solid Cords That Connect Data and Voice Circuits Lucent Technologies Family of Stranded Cords includes 110 patch, modular and adapter
More informationDatasheet: DSX CableAnalyzer Series
Datasheet: DSX CableAnalyzer Series Datasheet: DSX CableAnalyzer Series The DSX CableAnalyzer Series is the copper certification solution of the Versiv cabling certification product family. The DSX Series
More informationCopper Cabling Standards
Copper Cabling Standards White paper White Paper Copper Cabling Standards v2.0 EN 1 Introduction Standard specifications are the foundation upon which most cabling and networking projects are built. Professionals
More informationNGBASE-T Cabling Requirements
NGBASE-T Cabling Requirements Dr. T. C. Tan, DMTS, CommScope Labs B.Sc (Eng), DIC, PhD, CEng, FIET White paper www.commscope.com Contents Contents Contents 2 1.0 Introduction 3 2.0 IEEE 802.3 NGBASE-T
More informationLargest Cat 6A Installation in Midwest Pushes Frontiers of Networking Technology
Largest Cat 6A Installation in Midwest Pushes Frontiers of Networking Technology At a Glance Customer: Terrance Electric and Technology Company for HSBC Industry: Banking/Finance Location: Mettawa, Illinois
More informationFTTE Revisited for New Technologies
FTTE Revisited for New Technologies A new look into FTTE design to allow great flexibility as well as compliance to the latest 40G and 100G. Gautier Humbert, RCDD, CDCDP Business Development Manager Eastern
More informationDesign Guidelines. LANmark-6A Cabling System. January 2015 Revision 2.0. Nexans LANmark-6A Design Guidelines Ver January Page 1
Design Guidelines LANmark-6A Cabling System January 2015 Revision 2.0 Nexans LANmark-6A Design Guidelines Ver 2.0 - January 2015 - Page 1 This document is intended to provide general guidance on LAN cabling
More informationCopper Certification Testing Best Practices Pocket Guide
Copper Certification Testing Best Practices Pocket Guide Cabling certification is a best practice of world class installers because it shows the true quality of the installation and reduces the risk of
More informationAnixter Standards Reference Guide
Anixter: The Cabling System Experts Anixter is a leading global supplier of communications and security products, electrical and electronic wire and cable, fasteners and other small components. We help
More informationWhite Paper: Installing Data Networks Using LinkWare Live SaaS
White Paper: Installing Data Networks Using LinkWare Live SaaS White Paper: Installing Data Networks Using LinkWare Live SaaS Software as a Service (SaaS) continues to grow in popularity across a wide
More information1 of 5 12/31/2008 8:41 AM
1 of 5 12/31/2008 8:41 AM SAVE THIS EMAIL THIS Close All multimode fiber is not created equal By Robert Reid Bandwidth, reach, and cost are among the key factors you ll need to weigh. Multimode fiber cabling
More informationDeviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved.
TC500 Ethernet Cabling Certifier Operation Manual Version 1.13 Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved. Warranty This instrument is guaranteed for a period of 2 years
More informationMORE ETHERNET ON THE HORIZON WHO NEEDS 2.5G AND 5G ETHERNET? Krzysztof Ojdana, Product Manager WHITE PAPER. Molex Connected Enterprise Solutions
MORE ETHERNET ON THE HORIZON WHO NEEDS 2.5G AND 5G ETHERNET? Krzysztof Ojdana, Product Manager WHITE PAPER Molex Connected Enterprise Solutions EXECUTIVE SUMMARY Ethernet seems to be one of the fastest
More informationTraining Offer. Catalogue
Training Offer Catalogue docnr. 3.0 rev.date: 04 August 2008 2/13 Introduction, "The transmission quality of a cabling installation depends on the cabling system used, as well as the installation itself."
More information3M Telecommunications. Solutions for Networks. Volition 10G Copper Solutions. Innovation
3M Telecommunications Solutions for Networks Volition 10G Copper Solutions Innovation Volition 10G Copper Solutions In less than 10 years, the speed of local area networks (LAN) has gone from less than
More informationCommon Mistakes Made in Certification Specifications and Testing. Jim Davis Regional Marketing Engineer Fluke Networks
Common Mistakes Made in Certification Specifications and Testing Jim Davis Regional Marketing Engineer Fluke Networks Common Mistake #1 Failing to specify a Permanent Link test #1 Permanent Link or Channel?
More informationSolution. GigaSPEED SYSTIMAX. Evolutionary Design, Revolutionary Performance
SYSTIMAX GigaSPEED Solution Evolutionary Design, Revolutionary Performance A Proven Structured Connectivity Solution With Gigabit Power and Performance You re planning for the long run. And you can t afford
More informationThe six major components of a structured wiring system are:
OBJECTIVES 1. Describe various ANSI/TIA/EIA standards for commercial buildings and residential settings. 2. Discuss the specific Technical Systems Bulletins that can affect telecommunications installations.
More informationEthernet Cable Testing, Certifying & Diagnostics Jim Ralston Director of Sales
Softing Industrial Automation Data Exchange & Network Diagnostic Solutions Ethernet Cable Testing, Certifying & Diagnostics Jim Ralston Director of Sales Topics Softing Introduction Industrial Network
More informationA+ Guide to Managing & Maintaining Your PC, 8th Edition. Chapter 16 Networking Types, Devices, and Cabling
A+ Guide to Managing & Maintaining Your PC, Chapter 16 Networking Types, Devices, and Cabling Objectives Learn about network types and topologies Learn about the hardware used to build local networks Learn
More informationPhysical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks
Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks Agenda New ISO/IEC 11801 Standard New Fibre standards and encoding methods Higher speeds,
More informationScopeData Pro User s Guide
ScopeData Pro User s Guide Part Number N2605A-071 Version 3.0 Print Date: July 2002 Copyright 1999, 2000, 2001, 2002 Agilent Technologies. All rights reserved. Trademarks FrameScope and WireScope are registered
More informationPANGEN SYSTEM WARRANTY. Warranty Guide
PANGEN SYSTEM WARRANTY Warranty Guide C2-10270 PANGEN SYSTEMWARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction &
More informationOptical Fiber for Today s Premises Applications
Optical Fiber for Today s Premises Applications Tony Irujo Customer Technical Support Mgr. OFS Optical Fiber Division 508-347-8582 tirujo@ofsoptics.com 1 Copyright 2006 Fitel USA Corp., All rights reserved.
More informationOptiFiber Certifying OTDR Accessories Guide. See how Fluke Networks options and accessories can enhance your investment.
NETWORKSUPERVISION OptiFiber Certifying OTDR Accessories Guide See how Fluke Networks options and accessories can enhance your investment. Singlemode and Multimode Modules Contents Singlemode and Multimode
More informationCHAPTER 7 Copper Cable Testing
CHAPTER 7 Copper Cable Testing Lesson Objective After completing this lesson, you should be able to: i. Explain the various terms and instruments used to test copper cabling system. Cable Testing Cables
More informationTarleton State University. Specifications
Tarleton State University Campus Communication Infrastructure Specifications Cabling Standards Summary This document identifies Tarleton State University communication infrastructure standards. The communication
More informationPassive Infrastructure Technical Specification. Version 1 / March 14
Passive Infrastructure Technical Specification Version 1 / March 14 Contents INTRODUCTION 3 SERVICE OVERVIEW 4 HIGH LEVEL DESIGN 4 OPTIONS 8 CONTACTS 12 2 HEATHROW Technical Specification Passive Infrastructure
More informationDTX-PCxxS. Users Manual. Patch Cord Test Adapters
DTX-PCxxS Patch Cord Test Adapters Users Manual January 2011 2011 Fluke Corporation. All rights reserved. Printed in USA. All product names are trademarks of their respective companies. LIMITED WARRANTY
More informationCopper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only
1 Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only Gautier Humbert, RCDD Standards Coordinator Digital Infrastructures Legrand District Chair Mainland Europe BICSI 2 Agenda
More informationCERTIFICATION PLUS SM
CERTIFICATION PLUS SM SYSTEM WARRANTY PROGRAM Panduit Warranty Guide PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction & Installation
More informationWhite Paper: Choosing the RIght OTDR for your Datacenter
White Paper: Choosing the RIght OTDR for your Datacenter To ensure that fiber in datacenters is reliable, network professionals need a more accurate, easier, and faster methodology for assessing the integrity
More informationAdvanced Test Equipment Rentals ATEC (2832) OMNIScanner 2 OMNIFiber
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMNIScanner 2 OMNIFiber OMNISCANNER2 TM OMNIFIBER TM User Guide ENGLISH A Guide to using the OMNISCANNER to install,
More informationPANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY
PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents
More informationIndustry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"
Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print" Gautier Humbert, RCDD Standards Coordinator Legrand Digital Infrastructures Gautier Humbert, RCDD BICSI District Chair Mainland
More information9/27/04 cci Cablecom Inc. 1
cci Cablecom Inc. 1 CCI Cablecom Inc. is a privately held, women owned corporation headquartered in Aurora, CO. We manufacture a variety of voice and datacom products. Cable applications Include: Local
More informationSTANDARDS REFERENCE GUIDE ANIXTER anixter.com. Products. Technology. Services. Delivered Globally.
ANSI/TIA-568-C.0 ANSI/TIA-568-C.1 ANSI/TIA-568-C.2 ANSI/TIA-568-C.3 ANSI/TIA-569-D ANSI/TIA-606-B ANSI/TIA-607-C ANSI/TIA-862-A ANSI/TIA-942-A ANSI/TIA-1005-A ANSI/TIA-1179 ISO/IEC 11801 IEEE 802.3af IEEE
More informationAgilent Technologies N2600A WireScope 350. User s Manual. Agilent Technologies. Version 3.0
Agilent Technologies N2600A WireScope 350 User s Manual Version 3.0 Agilent Technologies 1RWLFHV Notices No part of this manual may be reproduced in any form or by any means (including electronic storage
More informationDATA CABLING - CRAWLING OUT OF THE MELTING POT?
DATA CABLING - CRAWLING OUT OF THE MELTING POT? prepared and delivered ϕ by The Cabling Partnership BSI, Chiswick, London 24th February 1999 Mike Gilmore Senior Partner, INTERNATIONAL ISO/IEC Member JTC1
More informationPARKING. JDSU Solutions for Enterprise Structured Cabling
COMMUNICATIONS TEST AND MEASUREMENT SOLUTIONS JDSU Solutions for Enterprise Structured Cabling JDSU offers a complete range of communications test and measurement solutions to address the needs of cabling
More informationANSI/TIA/EIA-568-B A P P E N D I X TECHNICAL INFORMATION. Contents ANSI/TIA/EIA-568-B. anixter.com
A The urpose: stablish a generic telecommunications cabling standard that will support a multivendor environment nable the planning and installation of a structured cabling system for commercial buildings
More informationNew standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks
New standards that have led to higher speeds and new cable categories Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks Three Realities of Networking #1 - Networks Never Go Slower Plan for higher
More informationIncrease Network Reliability and Reduce Costs with Cabling Management Software and Services Designed Especially for SYSTIMAX Installations
Here s Why You Need a Cable Management System You ve made a substantial investment in your cabling infrastructure. A cable management system protects that investment by allowing you to: Maximize network
More informationHANDBOOK OF CABLE TESTING
Testing and Measurement Technology Fault Analysis Documentation and Reporting HANDBOOK OF CABLE TESTING Wire pert Cable Certifier WX4500 Best-in-Class Certifier for today and tomorrow. CAT 8 Ready! CAT8
More informationVF-45 TM (SG) Ferrule-Less Interconnect Proposal
VF-45 TM (SG) Ferrule-Less Interconnect Proposal IEEE 802.5 Token Ring. November 10-12, 1998 Tad Szostak - 3M Telecom Systems Division 512-984-3847; tszostak1@mmm.com www.3m.com/volition Plug and Socket
More informationNetwork SuperVision Solutions
NETWORKSUPERVISION Network SuperVision Solutions For the Copper and Fiber Cabling Infrastructure LEADING THE WAY Grow your business Fluke Networks is the leading provider of innovative copper and fiber
More informationTECHNICAL DATA SHEET Family code C2424SOLPCORD CAT 6 UTP Solid. version 1 LSNH PATCHCORD date page 1/5
page 1/5 Application: High Density Switch & Hub Working area cord and telecommunications equipment cord in Local Area Networking environments Support current and future Category 6 applications, such as:
More informationRonald Tellas, Technology and Applications Manager, Enterprise Networking
Direct Connect Testing Guidelines Ronald Tellas, Technology and Applications Manager, Enterprise Networking Introduction Direct Connect is a viable option for the Digital Building that is being deployed
More information