UCS Engineering Details for the SAN Administrator

Size: px
Start display at page:

Download "UCS Engineering Details for the SAN Administrator"

Transcription

1

2 UCS Engineering Details for the SAN Administrator Craig Ashapa 2

3 First things first: debunking a myth Today (June 2012 UCS 2.02m) there is no FCoE northbound of UCS unless you really really really want to That s right, there is no FCoE on external Ethernet uplinks by default In other words, FCoE is used only at the access layer (Server to Fabric Interconnect) in a totally transparent manner You don t need to know anything about FCoE to understand how storage works with UCS Everything works as usual. Servers have HBAs that FLOGI into the SAN fabric, you use zoning and LUN masking just like you do with rackmounts today UCS release 1.4 introduced support for Direct Connect FCoE targets Today, this is the only case where you ll see FCoE traffic You ll have to go through explicit configuration steps to make this happen

4 Topics Introduction of Converged Network Adapters (CNAs) CNAs and Port WWNs Considerations UCS Storage modes of operation and recommendations End Host Mode - NPV (N_Port Virtualization) FC Switching Mode Upstream Connectivity F_Port Trunking / F_Port Channeling Direct Connectivity of Storage Port Types What works and what doesn t IP-Based Storage Appliance Ports iscsi

5 Introduction of Converged Network Adapters CNAs and Port WWNs Considerations

6 Unified Fabric with FCoE CNA: Converged Network Adapter Nexus Edge participates in both distinct FC and IP Core topologies CNA presents multiple PCI addresses to the Operating System (OS) OS loads two unique sets of drivers and manages two unique application topologies Server participates in both topologies since it has two stacks and thus two views of the same unified wire Host FC Multi-Pathing driver provides failover between two fabrics (SAN A and SAN B ) UCS hardware based Fabric Failover (preferred) or OS NIC Teaming provides Ethernet traffic failover FCF Unified Wire shared by both FC and IP topologies Ethernet Driver bound to Ethernet NIC PCI address 10GbE Ethernet Drivers Fibre Channel 10GbE Link PCIe Operating System Ethernet Fibre Channel Drivers FCF Nexus Unified Edge supports both FC and IP topologies FC Driver bound to FC HBA PCI address

7 CNA: Converged Network Adapter Operating System View Emulex / Qlogic / Cisco Standard drivers Same management Operating System sees: N port or Dual port (depending on hardware) 10 Gigabit Ethernet adapter N port or Dual Port (depending on hardware) Fibre Channel HBAs 7

8 vhbas: WWN assignment WWN assignment: just like Ethernet MAC addresses Either inherited from burnt-in WWN (not with M81KR!) Or manually set Or borrowed from a pool (recommended) Up to two HBAs (called vhbas) per server with non-m81kr CNAs Backplane path failover does not exist for HBAs! A vhba either goes through switch A or B at any given time OS-level multipathing provides path resiliency Same dynamic pinning concept as with 10GE NICs Manual override allowed by using SAN pin-groups

9 A word on World-Wide Name formats Avoid interop issues by choosing IEEE Extended Type 2 WW Names inside pools: Section 1 Section 2 Section 3 Section 4 2 0:00 00:25:B5 XX:XX:XX Section 1 identifies the WWN as an extended format WWN Section 2 is a vendor specific code and can be used to identify specific ports on a node or to extend the serial number (section 4) of the WWN Section 3 identifies the vendor (00:25:B5 = Cisco) Section 4 is the serial number for the device

10 Quick tip how do I determine my port WWNs? Determine the server s pwwn Assigned through the service profile Verify on the host it will match: Check local FLOGI for that pwwn on UCS and MDS: On Windows, use free fcinfo.exe utility

11 Fabric Interconnects Modes of Operation

12 What is NPV? N-Port Virtualizer (NPV) utilizes NPIV functionality to allow a switch to act like a server performing multiple logins through a single physical link Physical servers connected to the NPV switch login to the upstream NPIV core switch Physical uplink from NPV switch to FC NPIV core switch does actual FLOGI Subsequent logins are converted (proxy) to FDISC to login to upstream FC switch No local switching is done on an FC switch in NPV mode FC edge switch in NPV mode Does not take up a domain ID UCS Fabric Interconnect FC NPIV Core Switch F-Port Eth1/1 Server1 N_Port_ID 1 NP-Port F-Port Eth1/2 Server2 N_Port_ID 2 F_Port Eth1/3 Server3 N_Port_ID 3 N-Port

13 N-Port Virtualization (NPV) mode UCS FI works in NPV mode by default Server-facing ports are regular F ports Uplinks toward SAN core fabric are NP ports UCS distributes (relays) FCIDs to attached devices No domain ID to maintain locally Zoning, FSPF, DPVM, etc are not configured on the UCS Fabrics Domain Mgr, FSPF, Zone Server, Fabric Login Server, Name Server They do not run on UCS Fabrics No local switching All FC traffic routed via the core SAN switches

14 UCS Storage Defaults and Recommendations for FC Default (recommended) - N_Port Virtualization (NPV) Mode End Host Mode for FC, UCS functions as Node Port (initiator) Small to Large Scale Deployments of homogeneous or heterogeneous operating systems Extensive interoperability with SAN and array ecosystem Option - FC Switching Mode UCS FI has limited FC switching features, No Zoning Configuration Must still have upstream MDS or Nexus FC switch via FC Uplink Direct Connect from Fabric Interconnect to Storage Array FC target Designed for POD or Small scale Limited interoperability with Storage ecosystem

15 UCS Storage Defaults and Recommendations for FCoE Default FCoE Traffic is internal to UCS system (blade to Fabric Interconnect) FCoE packets are terminated at the fabric interconnect, no northbound FCoE packets transmitted from UCS Options FC Switching Mode UCS FI has limited FC switching features, no zoning configuration Must still have upstream MDS or Nexus FC switch via FC Uplink Direct Connect from Fabric Interconnect to Storage Array(s) FCoE target Use of FCoE Storage Targets with UCS Limited interoperability with Storage ecosystem

16 UCS Storage Defaults and Recommendations for NAS Default (recommended) - End Host Mode Superior traffic engineering - Native L2 multipathing; no spanning-tree Easier integration into network 1.4 Introduced Appliance Ports which allow direct connect NAS filers Options - Ethernet Switching Mode As of 1.4 no storage based reasons to use this mode Previous releases required switching mode for direct connect NAS

17 UCS Connectivity Summary LAN CLOUD SAN Switch Upstream Switch in NPIV Mode FC STORAGE NAS STORAGE LAN Switch UCS Ethernet in EHM UCS FC in NPV Mode UCS Fabric Interconnect Access Layer LAN & SAN Unified Fabric (FCoE)

18 Upstream Connectivity SAN Uplinks, Port Channels and Trunks

19 FC Uplink VSAN Membership Default SAN integration is very straightforward: Connect UCS to external SAN switch (MDS / Brocade) Make FC uplink member of one and only one VSAN No F_Port or NP_Port trunking by default

20 FC Port Trunking (Multiple VSANs per Link) Provide isolation to SAN traffic over the same physical FC link Help consolidate FC infrastructure vhbas can be on different VSANs Uplink FC ports will be in NPV mode (N- Port) by default All VSANs will be trunked on every uplink FC port Selecting a subset of VSANs for individual uplink ports not supported Scalability: Max of 32 VSANs per UCS system VSAN trunking supported in FC switch mode as well VSAN Trunking is not available for direct connect FC (or FCoE) Storage Port types SAN A SAN B vfcs VSAN 100 VSAN 200 VSAN 300 VSAN 400

21 FC Port Channels Aggregate and maximize available bandwidth while maintaining isolation Increases resiliency and guard against port failures Up to 16 FC ports can be aggregated together for a single port channel Different combination of FC ports from different expansion modules on the FI can be placed on the same port channel vfcs In case of port speed mismatch port channel forces port speed to highest commonly supported speed VSANs can be trunked over the port channel Port Channel VSAN 100 VSAN 200 VSAN 300 VSAN trunking and port channel supported for both NPV and switch mode FI operation FC Port channeling is not available for direct connect FC Storage Port types SAN A SAN B VSAN 400

22 How FC Trunking Is Enabled (Global) Global Setting for both FIs Default is Not enabled

23 Creation and Management of FC Port Channels

24 Fabric Interconnects FC and Direct Storage Connectivity Options

25 FC SAN Boot Create Service Profile Configure Storage (simple or expert) Create vhba s (1, 2, or more (M81KR)) Assign Initiator WWPN (manual or pool) Assign VSAN to vhba s Assign vhba Placement Select or Create Boot Policy Assign Target WWPN and LUNID Associate Server Zone Mask Boot to vmedia Install Drivers and OS

26 Enable Direct Connection of FC/FCOE Storage Customer benefits Support to directly connect FC/ FCoE storage to 6100 End to end FCoE topologies possible Lower cost point for small deployments (no access layer FC switches) FCoE Storage FC Storage Feature details Support for NetApp and EMC direct attached storage Ability to turn On/Off Fibre Channel switching mode Zoning configuration not exposed with UCS Manager Zoning must be inherited from upstream switch Ethernet and FC switching modes are independent UCS 6100 UCS 6100 UCS B-Series

27 UCS Direct Connect Storage Three UCS port types related to direct storage capability Storage FC Port direct connect this port to FC port on array Storage FCoE Port direct connect this port to FCoE port on array Appliance Port - direct connect this port to 10G Ethernet port on array

28 UCS Manager View of New Ports

29 Hybrid Topology with Direct-Attach and SAN SAN Fabric Storage Arrays Fibre Channel Direct Attach Fabric A Core Fabric B Ethernet Unified I/O FC Storage FCoE Storage FCoE SAN Edge A SAN Edge B UCS 6100 UCS 6100 Security via Zoneset Merge AND Security via LUN Masking LUN Masking Always Used to Some Extent UCS B-Series

30 How to Place FI into FC Switching Mode This operation results in both FIs going into reboot cycles which takes 15 min or so, system wide downtime, by design When FC switch mode is turned on, all the FC ports come up in TE mode

31 Configuring an FC Storage Port To connect an FC storage device directly into one of the 6100 s FC port, the user must configure the port as an FC storage port The VSAN is configured under the Storage Cloud object Internally, the port is configured as follows: As a F_Port As an access port The speed is kept as auto The user is also allowed to select a named VSAN for that port.

32 Configuring an FC Storage Port (GUI)

33 Configuring a VSAN on an FC Port (GUI)

34 Configuring an FCoE Storage Port (GUI)

35 Configuring an FCoE Storage Port (Cont.) Since the Ethernet port is configured as trunk, a native VLAN must be configured on that port. The FCoE VLAN ID can not be the same as the native VLAN ID User is not requested to provide a native VLAN value. An arbitrary VLAN (4048) was chosen and is always used as the native VLAN for FCoE storage ports unless changed

36 FCoE Port Must Be Assigned to a VSAN

37 IP-based Storage Appliance Ports and iscsi

38 UCS Manager Appliance Ports What is an Ethernet Appliance A specialized device for use on a Ethernet network, for example Network Attached Storage, iscsi, security appliances, Nexus 1010 What qualifies to be an appliance An Appliance is a specialized external host, does not run STP (today only NetApp and EMC IP storage devices qualified) Purpose of Appliance Port Connect Ethernet appliances only! Do Not to use this port type for switch connectivity to avoid traffic loops

39 Appliance Ports How to Configure

40 Appliance Port Exposed Settings QoS per port settings, normal UCS QoS constructs Manual (static) pinning using pin groups for border port selection Select which VLANs can traverse this port Optionally specify the destination MAC address of the filer. Some Filers do not broadcast their MAC address

41 VLANs and Appliance Ports Similar to VSAN concept, there are two scopes Traditional, LAN Cloud Appliance Cloud with scope restricted to appliance ports and associated VLANs Use the same VLAN ID in both scopes

42 iscsi Feature Overview

43 iscsi Boot Flow Create iscsi vnics Create iscsi boot policy Provide UCSM with iscsi boot information Target ip, iqn Initiator ip/mask/gw, iqn vmedia map the OS and drivers Adapter successfully initializes Install OS and Drivers (if required) 43

44 Storage Vendor Support UCS 1.4 Direct Connect only support EMC and NetApp for all topologies (FC, FCoE, NAS) We may add more vendors as a function of time given business case justifications iscsi Boot will only support EMC and NetApp Arrays We may add more vendors as a function of time given business case justifications Please Consult the these resources B_rel2.02.pdf

45 Complete Your Online Session Evaluation Give us your feedback and you could win fabulous prizes. Winners announced daily. Receive 20 Passport points for each session evaluation you complete. Complete your session evaluation online now (open a browser through our wireless network to access our portal) or visit one of the Internet stations throughout the Convention Center. Don t forget to activate your Cisco Live Virtual account for access to all session material, communities, and on-demand and live activities throughout the year. Activate your account at the Cisco booth in the World of Solutions or visit 45

46 Presentation_ID

UCS Supported Storage Architectures and Best Practices with Storage

UCS Supported Storage Architectures and Best Practices with Storage UCS Supported Storage Architectures and Best Practices with Storage First Things First: Debunking a Myth Today (June 2012 UCS 2.01x) there is no FCoE northbound of UCS unless you really, really, really

More information

UCS Technical Deep Dive: Getting to the Heart of the Matter

UCS Technical Deep Dive: Getting to the Heart of the Matter UCS Technical Deep Dive: Getting to the Heart of the Matter Session ID Agenda Introductions UCS Architecture, Innovations, Topology Physical Building Blocks Logical Building Blocks Typical Use Cases (Live

More information

UCS Networking 201 Deep Dive

UCS Networking 201 Deep Dive UCS Networking 20 Deep Dive BRKCOM-2003 Brad Hedlund bhedlund@cisco.com Manish Tandon mtandon@cisco.com Agenda Overview / System Architecture Physical Architecture Logical Architecture Switching Modes

More information

UCS Direct Attached Storage and FC Zoning Configuration Example

UCS Direct Attached Storage and FC Zoning Configuration Example UCS Direct Attached Storage and FC Zoning Configuration Example Document ID: 116082 May 23, 2013 Contents Introduction Prerequisites Requirements Components Used Conventions Background Information UCS

More information

UCS SAN Deployment Models and Best Practices

UCS SAN Deployment Models and Best Practices UCS SAN Deployment Models and Best Practices Craig Ashapa, Technical Marketing Engineer Topics Introduction of Converged Network Adapters (CNAs) CNAs and Port WWNs Considerations UCS Storage Modes of Operation

More information

UCS Fabric Fundamentals

UCS Fabric Fundamentals UCS Fabric Fundamentals Hardware State Abstraction MAC Address NIC Firmware NIC Settings UUID BIOS Firmware BIOS Settings Boot Order BMC Firmware Drive Controller F/W Drive Firmware State abstracted from

More information

Direct Attached Storage

Direct Attached Storage , page 1 Fibre Channel Switching Mode, page 1 Configuring Fibre Channel Switching Mode, page 2 Creating a Storage VSAN, page 3 Creating a VSAN for Fibre Channel Zoning, page 4 Configuring a Fibre Channel

More information

FCoE Cookbook for HP Virtual Connect

FCoE Cookbook for HP Virtual Connect Technical whitepaper FCoE Cookbook for HP Virtual Connect Version 4.45 Firmware Enhancements August 2015 Table of contents Change History 6 Purpose 7 Overview 7 Requirements and support 7 Supported Designs

More information

Design and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems

Design and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems Design and Implementations of FCoE for the DataCenter Mike Frase, Cisco Systems SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies

More information

UCS Networking Deep Dive

UCS Networking Deep Dive UCS Networking Deep Dive BRKCOM-2003 www.ciscolivevirtual.com Agenda Overview / System Architecture Physical Architecture Logical Architecture Switching Modes of the Fabric Interconnect Fabric Failover

More information

Fibre Channel Zoning

Fibre Channel Zoning Information About, page 1 Support for in Cisco UCS Manager, page 2 Guidelines and recommendations for Cisco UCS Manager-Based, page 4 Configuring, page 4 Creating a VSAN for, page 6 Creating a New Fibre

More information

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2.

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2. UCS-ABC Why Firefly Length: 5 Days Format: Lecture/Lab Course Version: 5.0 Product Version: 2.1 This special course focuses on UCS Administration and Troubleshooting UCS Manager 2.0 and provides additional

More information

UCS Fabric Fundamentals

UCS Fabric Fundamentals UCS Fabric Fundamentals Hardware State Abstraction MAC Address NIC Firmware NIC Settings UUID BIOS Firmware BIOS Settings Boot Order BMC Firmware Drive Controller F/W Drive Firmware State abstracted from

More information

UCS Management Deep Dive

UCS Management Deep Dive UCS Management Deep Dive Jeff Silberman UCS Technical Marketing Engineer 2 Agenda Introductions UCS Architecture, Innovations, Topology Physical Building Blocks Logical Building Blocks Typical Use Cases

More information

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch Document ID: 117280 Contributed by Padmanabhan, Cisco TAC Engineer. Mar 25, 2014 Contents Introduction Prerequisites Requirements

More information

UCS Networking Deep Dive. Neehal Dass - Customer Support Engineer

UCS Networking Deep Dive. Neehal Dass - Customer Support Engineer UCS Networking Deep Dive Neehal Dass - Customer Support Engineer Agenda Chassis Connectivity Server Connectivity Fabric Forwarding M-Series Q & A Cisco Unified Computing System (UCS) Single Point of Management

More information

Designing and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches

Designing and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches Designing and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches What You Will Learn The Cisco Unified Computing System helps address today s business challenges by streamlining

More information

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group 2 UCS Bundled Upgrades Useful for Staging, Labs, and Non Productions This does a very quick fast upgrade

More information

Cisco UCS Local Zoning

Cisco UCS Local Zoning Configuration Guide Cisco UCS Local Zoning Configuration Guide May 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 30 Contents Overview...

More information

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Document ID: 116248 Contributed by Jim Hicks and Shelley Bhalla, Cisco TAC Engineers. May 01, 2014 Contents Introduction Prerequisites

More information

Cisco CCIE Data Center Written (Beta) Download Full Version :

Cisco CCIE Data Center Written (Beta) Download Full Version : Cisco 351-080 CCIE Data Center Written (Beta) Download Full Version : https://killexams.com/pass4sure/exam-detail/351-080 Answer: A QUESTION: 105 What is the function of the WWPN pool? A. to assign WWPNs

More information

Traffic Monitoring. Traffic Monitoring

Traffic Monitoring. Traffic Monitoring , page 1 Creating a Session, page 6 Editing an Existing Session, page 7 Activating or Deactivating a Session, page 7 Deleting a Session, page 8 Traffic monitoring copies traffic, from one or more source

More information

N-Port Virtualization in the Data Center

N-Port Virtualization in the Data Center N-Port Virtualization in the Data Center What You Will Learn N-Port virtualization is a feature that has growing importance in the data center. This document addresses the design requirements for designing

More information

Troubleshooting the Cisco UCS Compute Deployment BRKCOM Cisco and/or its affiliates. All rights reserved.

Troubleshooting the Cisco UCS Compute Deployment BRKCOM Cisco and/or its affiliates. All rights reserved. Troubleshooting the Cisco UCS Compute Deployment 2 Agenda Troubleshooting Cisco UCS Overview Physical Setup Software Setup Configuration Path Tracing Maintenance Key Takeaways Q & A 3 Overview UCS Building

More information

CCIE Data Center Written Exam ( ) version 1.0

CCIE Data Center Written Exam ( ) version 1.0 CCIE Data Center Written Exam (350-080) version 1.0 Exam Description: The Cisco CCIE Data Center Written Exam (350-080) version 1.0 is a 2-hour test with 80 110 questions that will validate that a data

More information

Deployment Guide: Network Convergence with Emulex OneConnect FCoE CNA and Windows Server Platform

Deployment Guide: Network Convergence with Emulex OneConnect FCoE CNA and Windows Server Platform W h i t e p a p e r Deployment Guide: Network Convergence with Emulex OneConnect FCoE CNA and Windows Server Platform How to Deploy Converged Networking with a Windows Server Platform Using Emulex OneConnect

More information

DCNX5K: Configuring Cisco Nexus 5000 Switches

DCNX5K: Configuring Cisco Nexus 5000 Switches Course Outline Module 1: Cisco Nexus 5000 Series Switch Product Overview Lesson 1: Introducing the Cisco Nexus 5000 Series Switches Topic 1: Cisco Nexus 5000 Series Switch Product Overview Topic 2: Cisco

More information

LAN Ports and Port Channels

LAN Ports and Port Channels Port Modes, page 2 Port Types, page 2 UCS 6300 Breakout 40 GB Ethernet Ports, page 3 Unified Ports, page 7 Changing Port Modes, page 10 Server Ports, page 16 Uplink Ethernet Ports, page 17 Appliance Ports,

More information

Cisco Exam Questions & Answers

Cisco Exam Questions & Answers Cisco 642-995 Exam Questions & Answers Number: 642-995 Passing Score: 800 Time Limit: 120 min File Version: 36.9 http://www.gratisexam.com/ Exam Code: 642-995 Exam Name: Unified Computing Troubleshoot

More information

Configuring Fibre Channel Interfaces

Configuring Fibre Channel Interfaces This chapter contains the following sections:, page 1 Information About Fibre Channel Interfaces Licensing Requirements for Fibre Channel On Cisco Nexus 3000 Series switches, Fibre Channel capability is

More information

Configuring Cisco UCS Server Pools and Policies

Configuring Cisco UCS Server Pools and Policies This chapter contains the following sections: Global Equipment Policies, page 1 UUID Pools, page 3 Server Pools, page 5 Management IP Pool, page 7 Boot Policy, page 8 Local Disk Configuration Policy, page

More information

Cisco UCS Manager Storage Management Guide, Release 3.1

Cisco UCS Manager Storage Management Guide, Release 3.1 First Published: 2016-01-20 Last Modified: 2017-04-27 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387)

More information

Troubleshooting N-Port Virtualization

Troubleshooting N-Port Virtualization CHAPTER 9 This chapter describes how to identify and resolve problems that can occur with N-Port virtualization. It includes the following sections: Overview, page 9-1 Initial Troubleshooting Checklist,

More information

Host and storage system rules

Host and storage system rules Host and storage system rules Host and storage system rules are presented in these chapters: Heterogeneous server rules on page 185 MSA storage system rules on page 235 HPE StoreVirtual storage system

More information

CCIE Data Center Storage Networking. Fibre Channel Switching

CCIE Data Center Storage Networking. Fibre Channel Switching CCIE Data Center Storage Networking Fibre Channel Switching What is Fibre Channel? From a high level, replaces SCSI disk cable with a network From this To this What is Fibre Channel? Protocol stack primarily

More information

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects? Volume: 327 Questions Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects? A. primary first, and then secondary

More information

UCS Networking Deep Dive

UCS Networking Deep Dive UCS Networking Deep Dive Steve McQuerry, CCIE # 6108, UCS Technical Marketing @smcquerry 2 UCS LAN Deep Dive Agenda High-level system overview review of different Fabric Interconnects, IOM and Cisco adapters

More information

UCS deployment guide for Nimble Storage

UCS deployment guide for Nimble Storage Summary This article is intended as a how to guide to allow for successful deployment of Nimble Storage iscsi connectivity to Cisco UCS. Nimble Storage / Cisco UCS connectivity checklist: 1) Determine

More information

UCS Management Architecture Deep Dive

UCS Management Architecture Deep Dive UCS Management Architecture Deep Dive Agenda Introductions UCS Architecture, Innovations, Topology Physical Building Blocks Logical Building Blocks Typical Use Cases (Live UCS Demo) Programmable Infrastructure

More information

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections:

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections: This chapter contains the following sections: Information About FCoE NPV, page 1 FCoE NPV Model, page 3 Mapping Requirements, page 4 Port Requirements, page 5 NPV Features, page 5 vpc Topologies, page

More information

Configuring Cisco UCS Server Pools and Policies

Configuring Cisco UCS Server Pools and Policies This chapter contains the following sections: Global Equipment Policies, page 1 UUID Pools, page 4 Server Pools, page 5 Management IP Pool, page 7 Boot Policy, page 8 Local Disk Configuration Policy, page

More information

www.passforsure.co 642-999 www.passforsure.co QUESTION: 1 When upgrading a standalone Cisco UCS C-Series server, which method is correct? A. direct upgrade on all components B. Cisco Hardware Upgrade Utility

More information

Windows 2012 NPIV on UCS Configuration Example

Windows 2012 NPIV on UCS Configuration Example Windows 2012 NPIV on UCS Configuration Example Document ID: 116471 Contributed by Felipe de Mello and Marcin Latosiewicz, Cisco TAC Engineers. Jul 21, 2014 Contents Introduction Prerequisites Requirements

More information

Configuring Service Profiles

Configuring Service Profiles Configuring Service Profiles This chapter includes the following sections: Service Profiles that Override Server Identity, page 1 Service Profiles that Inherit Server Identity, page 2 Service Profile Templates,

More information

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide Technical white paper vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide Updated: 4/30/2015 Hongjun Ma, HP DCA Table of contents Introduction...

More information

Inter-VSAN Routing Configuration

Inter-VSAN Routing Configuration CHAPTER 16 This chapter explains the inter-vsan routing (IVR) feature and provides details on sharing resources across VSANs using IVR management interfaces provided in the switch. This chapter includes

More information

Cisco MDS 9000 Family Blade Switch Solutions Guide

Cisco MDS 9000 Family Blade Switch Solutions Guide . Solutions Guide Cisco MDS 9000 Family Blade Switch Solutions Guide Introduction This document provides design and configuration guidance for administrators implementing large-scale blade server deployments

More information

Unified Storage Access Design

Unified Storage Access Design Unified Storage Access Design Unified Storage Access Design Agenda Why Unified Fabric? 101 The Storage Basics SAN iscsi & NAS Storage Design Essentials Understanding FCoE Quality of Service At The Edge

More information

Cisco Actualtests Questions & Answers

Cisco Actualtests Questions & Answers Cisco Actualtests 642-999 Questions & Answers Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 22.8 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot Cisco

More information

Overview of Cisco Unified Computing System

Overview of Cisco Unified Computing System Overview of Cisco Unified Computing System This chapter includes the following sections: About Cisco Unified Computing System, page 1 Unified Fabric, page 2 Server Architecture and Connectivity, page 4

More information

The Virtual Machine Aware SAN

The Virtual Machine Aware SAN The Virtual Machine Aware SAN What You Will Learn Virtualization of the data center, which includes servers, storage, and networks, has addressed some of the challenges related to consolidation, space

More information

Reference Architecture. DataStream. UCS Direct Connect. For DataStream OS 2.6 or later Document # NA Version 1.08 April

Reference Architecture. DataStream. UCS Direct Connect. For DataStream OS 2.6 or later Document # NA Version 1.08 April DataStream For DataStream OS 2.6 or later Document # 310-0026NA Version 1.08 April 2017 www.cohodata.com Abstract This reference architecture describes how to connect DataStream switches to Cisco Unified

More information

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5 Technical Marketing Solutions Guide Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5 Document Revision Date Revision Description (author) 5/16/2014 1. 0 Draft release (mmclaughlin)

More information

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F. Dell Networking Solutions Engineering March 2012

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F. Dell Networking Solutions Engineering March 2012 Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F Dell Networking Solutions Engineering March 2012 Revisions Date Description Authors March 2012 Rev. Kevin Locklear

More information

UCS Networking Deep Dive

UCS Networking Deep Dive UCS Networking Deep Dive Sarva Chakravarthi Cisco Services UCS LAN Deep Dive - Agenda High-level System Overview Fabric Forwarding Mode of Operations Uplink Pinning Chassis / Fabric Extender Server Connectivity

More information

Next Generation Computing Architectures for Cloud Scale Applications

Next Generation Computing Architectures for Cloud Scale Applications Next Generation Computing Architectures for Cloud Scale Applications Steve McQuerry, CCIE #6108, Manager Technical Marketing #clmel Agenda Introduction Cloud Scale Architectures System Link Technology

More information

Configuring PortChannels

Configuring PortChannels This chapter provides information about PortChannels and how to configure the PortChannels. Finding Feature Information, page 1 Information About PortChannels, page 1 Prerequisites for PortChannels, page

More information

Large SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors

Large SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors White Paper Large SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors What You Will Learn As SANs continue to grow in size, many factors need to be considered to help scale

More information

Vendor: EMC. Exam Code: E Exam Name: Cloud Infrastructure and Services Exam. Version: Demo

Vendor: EMC. Exam Code: E Exam Name: Cloud Infrastructure and Services Exam. Version: Demo Vendor: EMC Exam Code: E20-002 Exam Name: Cloud Infrastructure and Services Exam Version: Demo QUESTION NO: 1 In which Cloud deployment model would an organization see operational expenditures grow in

More information

HP 6125XLG Blade Switch

HP 6125XLG Blade Switch HP 6125XLG Blade Switch FCoE Configuration Guide Part number: 5998-3726 Software version: Release 2306 Document version: 6W100-20130912 Legal and notice information Copyright 2013 Hewlett-Packard Development

More information

CCIE Data Center Lab Exam Version 1.0

CCIE Data Center Lab Exam Version 1.0 CCIE Data Center Lab Exam Version 1.0 CCIE Data Center Sky rocketing Popularity should not come as any surprise As per Cisco Global Cloud index, published in 2012, gave prediction that by 2016 nearly two

More information

ITBraindumps. Latest IT Braindumps study guide

ITBraindumps.   Latest IT Braindumps study guide ITBraindumps http://www.itbraindumps.com Latest IT Braindumps study guide Exam : 300-460 Title : Implementing and Troubleshooting the Cisco Cloud Infrastructure Vendor : Cisco Version : DEMO Get Latest

More information

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES I. Executive Summary Superior Court of California, County of Orange (Court) is in the process of conducting a large enterprise hardware refresh. This

More information

Active System Manager Release 8.2 Compatibility Matrix

Active System Manager Release 8.2 Compatibility Matrix Active System Manager Release 8.2 Compatibility Matrix Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Midmarket Data Center Architecture: Cisco Unified Computing System with the Cisco Nexus 1000V Switch

Midmarket Data Center Architecture: Cisco Unified Computing System with the Cisco Nexus 1000V Switch White Paper Midmarket Data Center Architecture: Cisco Unified Computing System with the Cisco Nexus 1000V Switch Abstract The Cisco midmarket architecture is designed to meet the needs of businesses with

More information

Question No : 3 Which is the maximum number of active zone sets on Cisco MDS 9500 Series Fibre Channel Switches?

Question No : 3 Which is the maximum number of active zone sets on Cisco MDS 9500 Series Fibre Channel Switches? Volume: 182 Questions Question No : 1 A network architecture team is looking for a technology on Cisco Nexus switches that significantly simplifies extending Layer 2 applications across distributed data

More information

Service Profiles and Templates

Service Profiles and Templates Service Profile Templates, page 1 Service Profiles, page 3 Service Profile Templates Service profile templates enable you to quickly create several service profiles with the same basic parameters, such

More information

UCS Uplink Ethernet Connection Configuration Example

UCS Uplink Ethernet Connection Configuration Example UCS Uplink Ethernet Connection Configuration Example Document ID: 110267 Contents Introduction Prerequisites Requirements Components Used Conventions Configure Network Diagram 1. Configure Uplink Ethernet

More information

UCS Management Deep Dive

UCS Management Deep Dive UCS Management Deep Dive Jason Shaw Cisco UCS Technical Marketing Engineer Agenda Introductions UCS Architecture, Topology Physical Building Blocks Logical Building Blocks Policy Driven Management UCS

More information

Cisco Cisco Data Center Associate Level Accelerated - v1.0 (DCAA)

Cisco Cisco Data Center Associate Level Accelerated - v1.0 (DCAA) Course Overview DCAA v1.0 is an extended hours bootcamp class designed to convey the knowledge necessary to understand and work with Cisco data center technologies. Covering the architecture, components

More information

Cisco Nexus 4000 Series Switches for IBM BladeCenter

Cisco Nexus 4000 Series Switches for IBM BladeCenter Cisco Nexus 4000 Series Switches for IBM BladeCenter What You Will Learn This document is targeted at server, storage, and network administrators planning to deploy IBM BladeCenter servers with the unified

More information

Cisco UCS Virtual Interface Card 1225

Cisco UCS Virtual Interface Card 1225 Data Sheet Cisco UCS Virtual Interface Card 1225 Cisco Unified Computing System Overview The Cisco Unified Computing System (Cisco UCS ) is a next-generation data center platform that unites compute, networking,

More information

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect Vblock Architecture Andrew Smallridge DC Technology Solutions Architect asmallri@cisco.com Vblock Design Governance It s an architecture! Requirements: Pretested Fully Integrated Ready to Go Ready to Grow

More information

UCS Fundamentals Aaron Kerr, Consulting Systems Engineer

UCS Fundamentals Aaron Kerr, Consulting Systems Engineer UCS Fundamentals Aaron Kerr, Consulting Systems Engineer Complementary UCS Sessions Check out www.ciscolive.com for previous session presentations and videos BRKCOM-2003 UCS Networking Deep Dive BRKCOM-2007

More information

You can monitor or use SPAN on port channels only for ingress traffic.

You can monitor or use SPAN on port channels only for ingress traffic. This chapter includes the following sections: Traffic Monitoring, page 1 Guidelines and Recommendations for Traffic Monitoring, page 2 Creating an Ethernet Traffic Monitoring Session, page 3 Creating a

More information

VersaStack for Data Center Design & Implementation (VDCDI) 1.0

VersaStack for Data Center Design & Implementation (VDCDI) 1.0 VersaStack for Data Center Design & Implementation (VDCDI) 1.0 COURSE OVERVIEW: VersaStack for Data Center Design and Implementation (VDCDI) is a four-day training program. The Cisco-IBM VersaStack validated

More information

Cisco MDS NX-OS Release 6.2Configuration Limits 2

Cisco MDS NX-OS Release 6.2Configuration Limits 2 Cisco MDS NX-OS Release 6.2 Configuration Limits Cisco MDS NX-OS Release 6.2Configuration Limits 2 Switch Level Fibre Channel Configuration Limits for Cisco MDS 9000 Series Switches 2 Fabric Level Fibre

More information

Evolution with End-to-End Data Center Virtualization

Evolution with End-to-End Data Center Virtualization Evolution with End-to-End Data Center Virtualization Yves Louis DC Virtualisation Technical Solution Architect Agenda Data Center Virtualization Overview Front-End Data Center Virtualization Core Layer

More information

SAN Configuration Guide

SAN Configuration Guide ONTAP 9 SAN Configuration Guide November 2017 215-11168_G0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Considerations for iscsi configurations... 5 Ways to configure iscsi

More information

Fibre Channel Networking for the IP Network Engineer and SAN Core Edge Design Best Practices Chad Hintz Technical Solutions Architect BRKVIR-1121

Fibre Channel Networking for the IP Network Engineer and SAN Core Edge Design Best Practices Chad Hintz Technical Solutions Architect BRKVIR-1121 Fibre Channel Networking for the IP Network Engineer and SAN Core Edge Design Best Practices Chad Hintz Technical Solutions Architect BRKVIR-1121 Session BRKVIR-1121 Abstract Fibre Channel Networking for

More information

Using native UCSM and CLI tools for Troubleshooting and Configuration

Using native UCSM and CLI tools for Troubleshooting and Configuration Troubleshooting UCS SAN Boot Using native UCSM and CLI tools for Troubleshooting and Configuration Author: Karl Vietmeier Last Updated: December 7, 2012 CONTENTS INTRODUCTION... 4 1 LAB CONFIGURATION...

More information

Cisco Designing Cisco Data Center Unified Fabric (DCUFD) v5.0. Download Full Version :

Cisco Designing Cisco Data Center Unified Fabric (DCUFD) v5.0. Download Full Version : Cisco 642-996 Designing Cisco Data Center Unified Fabric (DCUFD) v5.0 Download Full Version : https://killexams.com/pass4sure/exam-detail/642-996 Answer: A QUESTION: 156 Which three functions are provided

More information

ECE Enterprise Storage Architecture. Fall 2016

ECE Enterprise Storage Architecture. Fall 2016 ECE590-03 Enterprise Storage Architecture Fall 2016 Storage Area Network (SAN) Tyler Bletsch Duke University Adapted from the course Information Storage and Management v2 (module 5-6), published by EMC

More information

Fibre Channel Gateway Overview

Fibre Channel Gateway Overview CHAPTER 5 This chapter describes the Fibre Channel gateways and includes the following sections: About the Fibre Channel Gateway, page 5-1 Terms and Concepts, page 5-2 Cisco SFS 3500 Fibre Channel Gateway

More information

Configuring Server Boot

Configuring Server Boot This chapter includes the following sections: Boot Policy, page 1 UEFI Boot Mode, page 2 UEFI Secure Boot, page 3 CIMC Secure Boot, page 3 Creating a Boot Policy, page 5 SAN Boot, page 6 iscsi Boot, page

More information

Service Profiles. Service Profiles in UCS Manager

Service Profiles. Service Profiles in UCS Manager in UCS Manager, on page 1 that Override Server Identity, on page 2 that Inherit Server Identity, on page 2 Guidelines and Recommendations for, on page 3 Methods of Creating, on page 3 Inband, on page 7

More information

Jake Howering. Director, Product Management

Jake Howering. Director, Product Management Jake Howering Director, Product Management Solution and Technical Leadership Keys The Market, Position and Message Extreme Integration and Technology 2 Market Opportunity for Converged Infrastructure The

More information

Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets

Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets CLI Config Sheets Dell Networking Engineering November 2013 A Dell Deployment and Configuration Guide

More information

UCS Fundamentals. Conor Murphy Partner Systems Engineer. #clmel BRKCOM-1001

UCS Fundamentals. Conor Murphy Partner Systems Engineer. #clmel BRKCOM-1001 UCS Fundamentals Conor Murphy Partner Systems Engineer #clmel Abstract This session provides an introduction to Cisco UCS. It does not assume previous UCS familiarity and is intended as a basic introduction

More information

Virtual Networks: For Storage and Data

Virtual Networks: For Storage and Data Virtual Networks: For Storage and Data or Untangling the Virtual Server Spaghetti Pile Howard Marks Chief Scientist hmarks@deepstorage.net Our Agenda Today s Virtual Server I/O problem Why Bandwidth alone

More information

"Charting the Course... Designing Cisco Data Center Infrastructure (DCID) Course Summary

Charting the Course... Designing Cisco Data Center Infrastructure (DCID) Course Summary Course Summary Description v6.0 is a five-day instructor-led course that focuses on data center design based on Cisco solutions. The course includes theoretical content, as well as design oriented case

More information

Implementing Cisco Data Center Unified Computing (DCUCI)

Implementing Cisco Data Center Unified Computing (DCUCI) Implementing Cisco Data Center Unified Computing (DCUCI) Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 3.0 http://www.gratisexam.com/ Exam Topics Implement C-Series stand alone Implementing

More information

CISCO EXAM QUESTIONS & ANSWERS

CISCO EXAM QUESTIONS & ANSWERS CISCO 642-999 EXAM QUESTIONS & ANSWERS Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 32.5 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot CISCO 642-999

More information

"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary

Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary Description Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary v6.0 is a five-day instructor-led course that is designed to help students prepare for the Cisco CCNP Data Center

More information

CISCO EXAM QUESTIONS & ANSWERS

CISCO EXAM QUESTIONS & ANSWERS CISCO 642-999 EXAM QUESTIONS & ANSWERS Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 32.5 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot CISCO 642-999

More information

Course Description. Boot Camp Date and Hours: The class starts on Saturday 2 nd of April, 2016 Saturdays Only 8:00 AM 4:00 PM Central Standard Time

Course Description. Boot Camp Date and Hours: The class starts on Saturday 2 nd of April, 2016 Saturdays Only 8:00 AM 4:00 PM Central Standard Time Course Description Zero-to-Hero-UCS (Z2H-UCS) is a five-session workshop exploring the fundamentals of the Unified Computing System (UCS). The course teaches UCS LAN and SAN fundamentals, the physical

More information

Designing Cisco Data Center Unified Computing

Designing Cisco Data Center Unified Computing Designing Cisco Data Center Unified Computing Number: 642-998 Passing Score: 800 Time Limit: 120 min File Version: 1.1 http://www.gratisexam.com/ Sections 1. Drag and Drop 2. Questions 3. Hot Spot CISCO

More information

Expert Reference Series of White Papers. Cisco UCS B Series Uplink Strategies

Expert Reference Series of White Papers. Cisco UCS B Series Uplink Strategies Expert Reference Series of White Papers Cisco UCS B Series Uplink Strategies 1-800-COURSES www.globalknowledge.com Cisco UCS B Series Uplink Strategies Chris Olsen, Global Knowledge Instructor, Author,

More information

STORAGE CONSOLIDATION WITH IP STORAGE. David Dale, NetApp

STORAGE CONSOLIDATION WITH IP STORAGE. David Dale, NetApp STORAGE CONSOLIDATION WITH IP STORAGE David Dale, NetApp SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies and individuals may use this material in

More information

Configuring Service Profiles

Configuring Service Profiles This chapter includes the following sections: Service Profiles that Override Server Identity, page 1 Service Profiles that Inherit Server Identity, page 2 Guidelines and Recommendations for Service Profiles,

More information