CSL Product Brochure

Size: px
Start display at page:

Download "CSL Product Brochure"

Transcription

1 CSL Product Brochure

2 Controlled Systems Ltd have a long standing reputation as a leading supplier of Intrinsically Safe, high quality, robust, control and communication equipment for use in a wide range of safety critical industries, in the UK and overseas. CSL Product Brochure

3 Contents Intrinsically Safe HD IP Camera..4 RugiCAM-IP..4 LED Units...4 Intrinsically Safe Ethernet ET Range ET: IS Serial to Ethernet Gateway ET: IS Ethernet Media Converter ET: IS Ethernet Managed Switch ET: IS Ethernet Isolator ETplus: IS Ethernet Wireless Access Point/Bridge.7 OEM 8 CSL ExLAN.8 CSL BxLAN 9 947X Gigabit Ethernet Range ETG: 1Gb Media Converter/Switch ETRG: 4 Port 1Gb Redundant Switch ETG: 1Gb Broadband Modem ETG: 1Gb Ethernet Isolator.13 Intrinsically Safe Power Supplies PS PS PS-PLUS 15 PLUS PS PS-XXX Range I/O Modules PLC Intrinsically Safe PLC Serial Gateway Communication Module Digital Input Output Module Analogue Input Output Module Temperature Input Module Relay Output Module 19 Miscellaneous..20 RugiCAM IS CCTV System.21 TT420 Tilt Transducer.21 Hazardous Area Fuses 22 Machine Modem...22 Bespoke solutions..23 IS Radio Control System 24 HD Network Camera 24 MPT100 Module.25 IS Electronic Flowmeter 25 ES485 OEM Serial Communications to Wi-Fi.25 CSL Product Brochure Page 3 CONTENTS

4 Intrinsically Safe HD IP Camera RugiCAM - IP IS Camera Options Available: Part Number 9456-ET-AA 9459-ET-AA 9456-ET-CS 9459-ET-CS 9456-ET-SS 9456-ET-SS Description IP Camera - Aluminium Enclosre IP Camera (with Wi-Fi) - Aluminium Enclosure IP Camera - Steel Enclosure IP Camera (with Wi-Fi) - Steel Enclosure IP Camera - Stainless Steel Enclosure IP Camera (with Wi-Fi) - Stainless Steel Enclosure The RugiCAM-IP high definition (HD) IS Ethernet network camera enable plant managers across process industries worldwide to ensure they are operating safely in hazardous zone 1 and zone 2 areas. The first of its kind for the hazardous area market, the RugiCAM-IP camera monitors and provides enhanced visual safety to control and automation systems installed on site, and provides additional security and visibility to specific hazardous locations in plants so safe operation can be maintained. It is lightweight, connecting directly to compatible IS Ethernet systems up to 100 metres via a Cat5e cable or WiFi, and it allows for quick and easy maintenance, therefore enabling plants to save time and associated costs. LED Units A range of RugiCAM-IP LED Units are available to use in conjunction with the RugiCAM-IP Camera. Part Number 9457-IR-AA 9457-WH-AA 9457-GR-AA RD-AA 9457-IR-CS 9457-WH-CS 9457-GR-CS 9457-RD-CS 9457-IR-SS 9457-WH-SS 9457-GR-SS 9457-RD-SS Description IR LED Unit - Aluminium Enclosure White LED Unit - Aluminium Enclosure Green LED Unit - Aluminium Enclosure Red LED Unit - Aluminium Enclosure IR LED Unit - Steel Enclosure White LED Unit - Steel Enclosure Green LED Unit - Steel Enclosure Red LED Unit - Steel Enclosure IR LED Unit - Stainless Steel Enclosure White LED Unit - Stainless Steel Enclosure Green LED Unit - Stainless Steel Enclosure Red LED Unit - Stainless Steel Enclosure INTRINSICALLY SAFE HD IP CAMERA Page 4

5 Intrinsically Safe Ethernet Ethernet is now established as the preferred network for business and control layers in industry. In factory automation and the power industry it is rapidly being established as the device level network of choice. Page 5 INTRINSICALLY SAFE ETHERNET

6 9400 Ethernet Range The 9460-ET Series provides cost-effective Intrinsically Safe (IS) Ethernet equipment that can be installed and maintained easily in hazardous areas. The intrinsically safe hazardous area certification permits the components to be mounted in a Zone 1, or Division 1 hazardous area with connectivity into Zone 0 and the associated apparatus certification of the 9468-ET IS Ethernet isolator and 9491-PS IS power supply allow this equipment to be mounted in a Zone 2 hazardous area and connected to intrinsically safe equipment in a Zone 0 or 1, or Division 1 hazardous area ET: IS Serial to Ethernet Gateway The 9461-ET Ethernet Gateway gives existing Intrinsically Safe equipment Ethernet connectivity by allowing conventional serial communication port equipment to be connected to an Ethernet network. Two 9-way D-type serial ports are provided which are RS232/TTL compatible. In addition, the module s front panel screw terminals (T6 - T15) provide two RS485/RS422, 2- or 4- wire ports, giving a total of four serial ports. All ports can operate at speeds up to 115K2baud. Various protocols are available (e.g.: Serial Modbus, Modbus/TCP, Ethernet IP etc.) in addition to Serial Tunnelling ET: IS Ethernet Media Converter The 9465-ET 10/100Mbps Copper to Fibre Optic Media Converter allows an Ethernet network to be extended over a greater distance. A multi-mode fibre optic link may be up to 2km in length when running at 100Mbps and due to the use of 1300nm optics an extended distance of 5km is achievable at 10Mbps. Longer distances are achievable with single mode fibre. Longer distances are obtained by simply connecting a 9466 (10/100Mbps Ethernet Switch) between two 9465 media converters, effectively giving a 'repeater' function (This also provides 3x UTP ports available for local network connectivity), this can be repeated as required. The use of fibre optics gives exceptional immunity to noise and electrical interference, it is also used when connecting a Hazardous Area network to a Zone 2 / Safe Area network or device. Page ETHERNET RANGE

7 9466-ET: IS Ethernet Managed Switch The 9466-ET 10/100Mbps, Layer 2, Ethernet switch allows the Interconnection of CSL 9400-ET series networking modules via its 5 ports. It also enables an Ethernet network to cover a greater distance using either Cat5e cable or fibre-optic for longer spans. This capability is due to the low latency 'store and forward' mechanism integral to the switch, which ensures that the stringent timing associated with Ethernet is maintained ET: IS Ethernet Isolator The 9468-ET 10/100Mbps, Isolating Ethernet Barrier allows the interconnection of a Zone 2 or un-certified safe area device to the intrinsically safe 9400-ET series of Ethernet networking products, operating in the hazardous area. The isolating barrier provides a compact alternative solution to fibre optic cable and media converters and for when it is desirable to use Cat5e cables in preference to fibre ET ETplus plus: : IS Ethernet Wireless Access Point/Bridge The 9469-ETplus is a multi-functional module that can be used as an Access Point, Wireless Bridge (Client) or Wireless Repeater. When used in the Access Point (AP) mode, it allows wireless devices to connect through it and onto the wired Ethernet network, either in AD-HOC or Infrastructure modes. When used as a Bridge, it makes it possible to turn any 10/100 Ethernet device into a wireless device, or to connect two network segments together to make a single network (without the interconnecting wire or fibre optic). Additionally the module may also be used in its Wireless Repeater (WDS) mode to extend the range covered by a wireless network. Page ETHERNET RANGE

8 OEM CSL ExLAN The CSL ExLAN is an Intrinsically Safe (IS) 10/100Mbps Ethernet Interface incorporating CSL's patented technology. Dimensions : 40 x 40 x 8 mm. Connection to users PCB are via 2.54mm (0.1") pitch headers. This module is intended to simplify OEM product design and certification. It ensures full IS compatibility of interconnected devices including the current range of 9400 IS Ethernet modules and future product ranges. As well as providing the essential network LAN interface, the module also voltage clamps the equipment s main supply rail (typically 5V or 3V3) together these ensure the Ethernet signals generated are limited to low Intrinsically Safe levels. It is fully compatible with PoExTM (12VDC Power over Ethernet for Hazardous Areas). Page 8 OEM

9 CSL BxLAN The CSL BxLAN acts as a barrier so that an unsafe Ethernet Cable can be used in Zone 0, Zone1 and Zone 2 areas as well as Underground Coal Mines. Features The BxLAN is an I.S. Interface that allows a Zone 2, uncertified safe area device, or an Ex d device to connect to other IS 9400 Series Ethernet Equipment in the Hazardous Area It uses the same CSL Patented circuits as the ExLAN for I.S. Devices. But uses an enhanced Voltage Clamping circuit to give non-is Devices Ethernet connectivity. The two ports support speeds of 10/100Mb. It is designed to allow OEMs to integrate I.S. Ethernet into an uncertified safe area device. The figure below illustrates the differences between the CSL ExLAN for use within existing or planned I.S. Equipment and the CSL BxLAN being applied to non-i.s. Equipment: Page 9 OEM

10 947X Gigabit Range 9475-ETG 1Gb Media Converter/Switch The 9475-ETG Gigabit Copper to Fibre Optic Media Converter allows an Ethernet network to be extended over a greater distance. Longer distances are obtained by simply connecting a 9476-ETRG (Gigabit Ethernet Switch) between two 9475-ETG media converters, effectively giving a 'repeater' function (This also provides 3x UTP ports available for local network connectivity), this can be repeated as required. The use of fibre optics gives exceptional immunity to noise and electrical interference, it is also used when connecting a Hazardous Area network to a Zone 2 / Safe Area network or device. When mounted in a safe area the converter may be powered by a 12V dc general-purpose power supply and the 'IS op' approval allows connection of the fibre optic cable into the hazardous area. Page X GIGABIT RANGE

11 9476-ETRG 4 Port 1Gb Redundant Switch A High-availability Seamless Redundancy (HSR) and Parallel Redundancy Protocol (PRP) Gigabit Ethernet switch. Features: Conforms to PRP IEC (Clause 4) Conforms to HSR IEC (Clause 5) All the frame duplication/removal is done in hardware using a Link Redundancy Entity (LRE) usually by a Field Programmable Gate Array (FPGA). 0mS switch Over Time. 4 Port Managed Switch configured via Web Page 2 Ports can be configured for Fibre or Copper RJ45 Connection IEEE 1588v2 PTP Precision Time Protocol Default, Power Profile and IEC IEEE 802.1Q for VLAN based Ethernet Priorities SNMP RFC 1157/RFC 3410 SNTP RFC 4330 HSR & PRP Combined Configuration PRP protocol uses standard Ethernet Frames and non PRP equipment can be attached to the network. Only HSR nodes can be connected to a HSR Network. The function of the Ethernet redundancy links is done in a Xilinx Zync Field Programmable Gate Array (FPGA) that includes Dual Arm Core processors. Page X GIGABIT RANGE

12 9477-ETG 1Gb Broadband Modem The CSL 9477-ETG is an Intrinsically Safe (IS) Broadband Modem incorporating CSLs patented technology. This module features two IS Gigabit Ethernet ports that support 10/100/1000 speeds, this is compatible with existing 9400 IS Ethernet, future 9470 Gigabit IS Ethernet and any products containing the CSL ExLAN IS Ethernet Interface including the CSL RugiCAM-IP Network Camera. A pair of these units connected together using a 2-wire twisted pair cable will enable Ethernet networks to span distances of up to 2Km without using fibre optic cables. Actual link speed between units is up to 200Mbps depending on cable length and quality. Additional units may be added along the cable length in a multi-drop type configuration if required. An Industrial (non-is) version is also available having a line isolation voltage in excess of 1KV (2mm solid insulation) using a separate toroid line coupling unit. This allows the transmission line to be either directly coupled or by passing a core of the transmission line through the toroid coupler to achieve non-contact inductive coupling typically onto either power or pilot cores in mining machinery trailing cables. Features: Dimensions : 140 x 120 x 40 mm. DIN Rail Module Intrinsically Safe ATEX / IECEx Certification (pending) Ex ia IIB T4 Ga; Ex ia IIIC T135 C Da (non-mining), Ex ia I Ma (M1 mining). Ta = -40ºC to +70ºC 10/100/1000 BASE-T IS Ethernet Interface for standard Cat5e/Cat6 Ethernet Cabling Systems 12V IS Power supply (or 10-30Vdc on Industrial version) Ethernet over single twisted pair at up to 2Km with speeds of up to 200Mbps Simple Plug-and-Play or Configured Security modes available Optional Inductive coupler for non-contact connection to the transmission line. DIN rail mounting module Page X GIGABIT RANGE

13 9478-ETG 1Gb Ethernet IS Isolator The 9478-ETG is a Isolating Barrier that allows a Zone 2 or uncertified safe area device to connect to the Intrinsically Safe (IS) 2 port to allow connection to other 9400 Series of products in the hazardous area. The 9478-ETG is designed for Zone 2 hazardous area mounting inside a suitable enclosure. Status LEDs are provided on the front panel. The two ports support speeds of 10/100/1000Mb. The module operates from a single supply 20 to 30Vdc at approximately 350mA. Dimensions : 140 x 120 x 40 mm. DIN Rail Module Features: Zone 2 mountable for connections to Zone 0 and 1 Galvanically isolated RJ45 Ports Compact alternative solution to fibre optics and media convertors Intrinsically Safe ATEX /IECEx Certification (pending) Ex ia IIB T4 Ga; Ex ia IIIc T135 C Da (non-mining), Ex ia I (M1 mining). Ta = -40 C to 70 C 10/100/1000 Base-T IS Ethernet Interfaces for Standard Cat5e/Cat6e Ethernet Cabling Systems Part of the range of 947X Series IS Ethernet Modules Page X GIGABIT RANGE

14 Intrinsically Safe Power Supplies The 949x-PS range of CSL intrinsically safe (IS) isolated power supplies are ideal for providing power to instru- mentation in hazardous process areas. They offer a wide range of different IS output voltages, ranging from 4.8V V, offering flexibility of options to best suit a variety of applications. Page 14 INTRINSICALLY SAFE POWER SUPPLIES

15 Intrinsically Safe Power Supplies The 949x-PS range of CSL intrinsically safe (IS) isolated power supplies are ideal for providing power to instrumentation in hazardous process areas. They offer a wide range of different IS output voltages, ranging from 4.8V V, offering flexibility of options to best suit a variety of applications. The 9492-PS-PLUS is the preferred method for supplying the 9400 range of CSL IS Ethernet devices to provide direct power or IS Power over Ethernet (PoExTM), a method which allows a single cable to provide both the data connection and electrical power to devices, in turn, reducing installation costs PS The 9491-PS Power Supply is the preferred method for supplying the 9460-ET series of intrinsically safe Ethernet modules and is based on an isolating power supply. It takes a 24V DC safe area / Zone 2 / Division 2 supply and produces an intrinsically Safe, 12V DC nominal output capable of powering the Ethernet modules mounted in a Zone 1 / Division 1 hazardous area. The 9491-PS maybe mounted in a safe area, Zone 2 or Division 2 hazardous area. Each 9491-PS can power a single Ethernet module. In order to provide multiple outputs required for several Ethernet modules, the 9491-PS power supply module is ganged up to the required number of ways, either DIN rail mounted or using the power distribution backplane to simplify the 24VDC input connection to the modules PS PS-PLUS PLUS The 9492-PS-PLUS is part of CSL s range of next generation power supplies, providing an increased temperature range and output current. The 9492-PS-PLUS power supply is the preferred method for supplying the 9460-ET series of intrinsically safe Ethernet modules and the RugiCAM-IP, and is based on an isolating power supply. It takes a 24V DC safe area / Zone 2 supply and produces an intrinsically safe, 12V DC nominal output capable of powering the Ethernet modules mounted in a Zone 1 hazardous area. The 9492-PS-PLUS may be mounted in a safe area or Zone 2 hazardous area. The output can be from either the Ex ia IIB or Ex ib IIB output connectors depending upon application. The ib IIB output providing a higher usable output power where the Gas Group and Zone allows. Page 15 INTRINSICALLY SAFE POWER SUPPLIES

16 9493-PS PS-XXX RANGE The 9493-PS-XXX Power Supply is a general purpose Intrinsically Safe power supply unit. It takes a 24V DC safe area or Zone 2 supply and produces an Intrinsically Safe output available in a range of different DC voltages. The 9493-PS-XXX may be mounted in a safe area or Zone 2 hazardous area. Standard Stock Range P/N Gas Group Uo Nominal Output Voltage Nominal Output Current Custom Range (Build to Order) 9493-PS-C5 IIC 5.4V 4.8V V 180mA 9493-PS-B5 IIB 5.4V 4.8V V 250mA 9493-PS-C6 IIC 7V 5.7V V 300mA 9493-PS-C9 IIC 10V 8.4V V 300mA 9493-PS-C11 IIC 12V 9.9V V 300mA 9493-PS-C12 IIC 13V 10.8V V 250mA 9493-PS-C14 IIC 15V 12.4V V 120mA 9493-PS-B14 IIB 15V 12.4V V 250mA 9493-PS-C17 IIC 18V 15.0V V 60mA 9493-PS-B17 IIB 18V 15.0V V 160mA P/N Gas Group Uo Nominal Output Voltage Nominal Output Current 9493-PS-C7 IIC 8V 6.6V V 300mA 9493-PS-C8 IIC 9V 7.6V V 300mA 9493-PS-C10 IIC 11V 9.1V V 300mA 9493-PS-A13 IIA 14V 11.3V V 470mA 9493-PS-B13 IIB 14V 11.3V V 380mA 9493-PS-C13 IIC 14V 11.3V V 160mA 9493-PS-M14 I 15V 12.4V V 460mA 9493-PS-A14 IIA 15V 12.4V V 410mA 9493-PS-M15 I 16V 13.2V V 440mA 9493-PS-A15 IIA 16V 13.2V V 300mA 9493-PS-B15 IIB 16V 13.2V V 230mA 9493-PS-C15 IIC 16V 13.2V V 100mA 9493-PS-M16 I 17V 14.1V V 300mA 9493-PS-A16 IIA 17V 14.1V V 270mA 9493-PS-B16 IIB 17V 14.1V V 190mA 9493-PS-C16 IIC 17V 14.1V V 70mA 9493-PS-M17 I 18V 15.0V V 300mA 9493-PS-A17 IIA 18V 15.0V V 210mA INTRINSICALLY SAFE POWER SUPPLIES Page 16

17 9600 Series I/O Modules Features: Software to monitor all Voltage Rails of the module. Communication to be Standard Ethernet Modbus TCP/IP. Support for Ethernet Dual UTP. The inbuilt switch allows for I/O Modules to link with each other without the need for an external switch. The two ports support speeds of 10/100Mb. Wireless option instead of LAN (Wi-Fi n 2.4 & 5 GHz). Option IEEE 1588 Time Stamp of Ethernet Packets to be considered. LED status indication for all channels. Configured via Web Page SERIES I/O MODULES Page 17

18 9600 Series I/O Modules 9660-PLC Intrinsically Safe PLC The 9660-PLC is designed for hazardous-area mounting inside a suitable enclosure with Intrinsically Safe Zone 1, ATEX and IECEx certification and Division 1 FM USA and Canada approvals. The ATEX and IECEx approvals cover both surface industry and mining application. Certified for use in Group 1 and Group II (Zone 1 &2). The PLC can be operated in a wide temperature range of 20 C to +70 C. Hardware ARM9 RISC 32 bit processor 155MHz, 32 Mb Ram, 1MB Flash, 10/100Mb Ethernet Port. The PLC may be powered by an intrinsically safe power supply or by Power over IS Ethernet (PoEx) providing intrinsically safe power and Ethernet communications over a single Cat5e cable. Soft PLC Isagraf V5, PLC loop times fixed at 25mSecs, PLC to PLC communication, Download and Upload PLC configuration, Remote Debugging from Safe Area via Ethernet to a PC. Soft PLC supports the following programming languages: The I/O connection to the PLC is achieved by interfacing to other 9600 series I/O Modules via an Ethernet communication fail safe link. Four Serial Communication Ports are available for serial remote I/O connection. Two 9-way D-type serial ports are provided which are RS232/TTL compatible. In addition, the module s front panel screw terminals (T6 - T15) provide two RS485/ RS422, 2- or 4- wire ports, giving a total of four serial ports. All ports can operate at speeds up to 115K baud rate has been used in Over 100 Applications worldwide. These include the control and monitoring of the following applications: Conveyors, Pumps, Tripper Drives, Booster Fans, Man and Standby Ventilation Fans, Methane Drainage Plants, Switchgear Control. Ladder Logic, Function Block, Sequential Function Chart, Structured Text, Instruction List, Flow Chart Serial Gateway Communication Module Serial to Ethernet Communications Module. Features: 4 Communication Ports - RS232/485(2&4W) Serial Modbus Protocol Bluetooth V4.0 Dual Mode Wi-Fi n (2.4 & 5 GHz) Micro Access Point Dual Port Switch 10/100Mb LAN (gives in/out capability) Serial to LAN Serial to Bluetooth Serial to WIFI Bluetooth to LAN WI-FI to LAN WI-FI, Bluetooth & LAN co-existence Modbus TCP/IP Protocol Page SERIES I/O MODULES

19 9620 Digital Input Output Module Features: 8 channels configured by software either input or output Duplicate non-equivalent circuits (SIL2) Detection of open and short circuit Output monitoring circuits (SIL2) LED status indication for all channels (Flashing Red with cable fault) Software Noise Filtering Number of operations recorded of the last 24 hours Channel Name and State Name Configurable NAMUR Input / Output support 9630 Analogue Input / Output Module Features: 8 Channels can be individually configured by software for Voltage or Current (4 20mA) Input. Connected to a 24 Bit Analogue to Digital Convertor. Short and open circuit detection. Modem fitted for Hart Communications. LED status indication for all channels. Log inputs for last 15 minutes 250mSecs between recordings in a ring buffer. Min/Max/Actual analogue values to be shown with ability to reset max/min values. Channel Name and measurement unit configurable Temperature Input Module Features: 8 Channels can be individually configured by software for Thermocouples, RTDs and Thermistor. Connected to a 24 Bit Analogue to Digital Convertor. Automatic Thermocouple Cold Junction Compensation. Configurable by software for 2,3 or 4 Wire RTDs. Can measure virtually all standard Thermocouples (type B,E,J,K,N,S,R,T). LED status indication for all channels. Log last 15 minutes 250mSecs between recordings in a ring buffer. Min/Max/Actual analogue values to be shown with ability to reset max/min values. Channel Name and measurement unit configurable Relay Output Module Features: 8 Channels 250Vac / 48Vdc / 5A SPCO contact output. Duplicate non-equivalent circuits (SIL2). Output monitoring circuits (SIL2). LED status indication for all channels. Number of operations recorded for the last 24 hours. Channel Name and State Name Configurable. Page SERIES I/O MODULES

20 Miscellaneous Products Additional high quality products available for use in a wide range of safety critical industries and Hazardous Areas. Page 20 MISCELLANEOUS PRODUCTS

21 RugiCAM Intrinsically Safe CCTV System The CSL RugiCAM is an Intrinsically Safe (IS) Camera and LCD monitoring system. It is designed and manufactured for use in harsh mining and tunnelling environments, including Hazardous Areas such as underground coal mines. Application - Mining and Tunnelling - Road Headers, Continuous Miners, Locomotives.. It features advanced technology that provides quality full colour video pictures from one or two miniature cameras, these can be switched manually or automatically (e.g.:- when vehicle is reversing). Each camera is connected to the main LCD display unit with a single cable that powers the camera from the display end and returns the video signal back to the display screen Ideal for applications needing a compact size in harsh environments, e.g.:- In mining and tunnelling when fitted to Free Steered Vehicles (FSVs) gives the driver better visibility of what were previously blind spots both in front and at the rear of the vehicle, especially when large loads are being transported, enhancing the heath and safety of the workforce. TT420 Tilt Transducer Features Rugged stainless steel housing suitable for machine mounting in harsh environments (e.g. mining) Solid-state, no moving parts for high reliability +/- 90deg range 4-20mA signal outputs (16-bit DAC) with HART (future option) RS485 communications - Modbus RTU Operating Temperature: -40ºC to +70ºC Hardware Low Pass Filter (LPF) on sensor signals 16-bit ADC with 64x oversampling and software digital filtering algorithms Intrinsically Safe ia Group I Mining M1 and Group IIB ATEX and IECEx Certified. MISCELLANEOUS PRODUCTS Page 21

22 Hazardous Area Fuses The CSL ExFuse series is a range of encapsulated fuses for use in Intrinsically Safe Apparatus for Hazardous Areas where there is a risk of explosion of gas and/or dust. CSL ExFuse Series of Values Available: Rated Current Voltage 1.0 x In (max) mv Melting Integral I²t 10 x In (min) A²Sec 63mA mA mA mA mA mA mA mA mA mA A A A Intelligent Machine Modem The Intelligent Machine Modem has been designed specifically for installation into mining machinery which is subjected to high vibration, shock and temperatures allowing reliable data transmission to another point e.g.- HVAC, switchgear or surface control room. The rugged steel enclosure houses proven custom built electronics. Each unit is operationally soak tested for 80ºC in the factory to ensure reliable operation in use. Manufacturers worldwide have been specifying CSL modems as standard in their machines for many years, providing trouble free operation and enhancing their own products. Page 22 MISCELLANEOUS PRODUCTS

23 Bespoke Solutions Controlled Systems Ltd. have a great reputation of providing high quality bespoke solutions that meet the specific needs of individual companies. This section provides examples of these customised products supplied by CSL to a variety of companies that are then sold around the world. Page 23 BESPOKE SOLUTIONS

24 Intrinsically Safe Radio Control System The system features Bi-Directional Radio, with backup wire-bound handsets that as well as giving the operator total flexibility of machine control and the (optional) display version also enables them to access important operational information such as cutting speeds, boom heights, motor temperatures, outbye conveyor status etc. whilst still maintaining a safe distance from the operational machine. The Radio Handsets integral Li-ion battery is charged in the Safe Area using the 7.5V Charger Unit, or Charging/Diagnostic Station connected to the handsets antenna socket, the handset s internal charging and protection circuitry allow fully automatic charging. The handsets are designed and certified to meet the ATEX Directive (94/9/EC) and relevant IECEx requirements. They are for use in a Hazardous Area and may remain energised when an explosive atmosphere is present. The handsets are available in five versions: Radio Handset Radio Handset with built-in AMOLED Display Wirebound Handset Display Navigation Handsets Mouse Handsets HD Network Camera CSL was approached by an existing customer to develop a specialised HD Network Camera to be used to assist in the operation of a coal cutting machine. Specific dimension restraints for the HD Network Camera had to met by CSL in order that it could be mounted within the constraints of the machine. Page 24 BESPOKE SOLUTIONS

25 Intrinsically Safe Electronic Flowmeter 4-20mA Flow Transducer CSL aided in the design and development of the Conflow Code 5050A Electronic Flowmeter. The Flowmeter is manufactured by CSL and supplied to Parker Hannifin Manufacturing Ltd group who in turn sell the Flowmeters around the world. The Flowmeter gives a linear electrical signal corresponding to the volume rate of flow of fluid in the pipeline or system. The moving magnet causes a Hall Effect Diode to produce a signal dependent on the strength of the magnetic flux around it. In this way the flow of fluid through the meter is transduced to a directly proportional electronic signal. The unit incorporates an on board LCD display showing rate, pressure and temperature. The transducer is also compatible with a wide range of instruments, data loggers, display devices and outstations to provide remote display of fluid flow, fluid temperature and totalisation of flow with respect to time. PT100 Motor Protection Module A CANBUS temperature and vibration monitoring unit for use in FLP enclosures for High Power Motors used in the Coal Mining Industry. Features: Rugged stainless steel enclosure suitable for mounting in harsh environments 6x 2 Wire PT100 Channels 2x Digital Input Channels 2x 4-20mA Inputs Channels Relay Output Channel Operating Temperature: -20ºC to +80ºC 24-bit ADC 12V / 24V Supply 180mA / 100mA (10VDC 29VDC) ES485 OEM Serial Communications to Wi-Fi CSL have developed a serial communications to Wi-Fi module so that a Hazardous Area Environmental Monitoring Company could interface their transducer onto a WIFI network. Page 25 Features: Allows any certified transducer in a Hazardous Area that uses a serial communications port WIFI, Bluetooth or Ethernet Copper Communication capability. Configuration of the transducer can be done by accessing the web page. Serial Communications Baud rate is done by a switch. Bluetooth V4.0 Dual Mode Wi-Fi a/b/g/n 2.4 GHz Channels GHz Channels Micro Access Point BESPOKE SOLUTIONS

26

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel. February 23, 2018 Annexe to: IECEx CML 15.0097X Issue 4 Applicant: Apparatus: HMI Elements Limited 470-Z1 Module Description of Equipment The 470-Z1 is a mains supplied, transportable hazardous area

More information

Intrinsically Safe Barriers

Intrinsically Safe Barriers Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

The iwap107 supports 100/1000Base-T, offering a significant increase in speed over the older fast Ethernet standard.

The iwap107 supports 100/1000Base-T, offering a significant increase in speed over the older fast Ethernet standard. iwap107 Zone 1 Universal Access Point Enclosure Wireless access point enclosure system Intrinsically safe RF outputs Explosion proof ATEX / IECEx Zone 1 certified US & Canada Class I Div 1 / Zone 1 certified

More information

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS ET-306-FX

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS ET-306-FX Operator Interface Operator Station 10" display, 640 x 480 pixels with resistive foil touch screen 12 function keys, 10 soft keys, 30 alphanumeric keys Zone 1, 2, 21, 22 and Division 2, optional GMP- compliant

More information

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5 EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on

More information

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous

More information

HAZARDOUS AREA DAY/NIGHT PTZ HD CAMERA

HAZARDOUS AREA DAY/NIGHT PTZ HD CAMERA ZCAM4 HAZARDOUS AREA DAY/NIGHT PTZ HD CAMERA DS-023 Issue 02 ZIZCAM Ltd are a UK based manufacturer of CCTV Cameras for use in the Hazardous Oil, Gas and Petrochemical industries. Consequently our products

More information

General. Remote I/O A4/1.

General. Remote I/O A4/1. www.stahl.de > Intrinsically safe Ex ia IIC, Ex e, Ex na or Ex nl inputs and outputs > Fieldbus communication: Modbus RTU, Profibus DP V0 and DP V1 HART, Industrial Ethernet, Modbus TCP, EtherNet/IP, PROFINET

More information

Hazardous Area Protection

Hazardous Area Protection Hazardous Area Protection Global Solutions in Hazardous Area Surge and Lightning Protection Intrinsic Safety When instrumentation is installed in a potentially explosive environment steps must be taken

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

MTL830 SERIES. Cuts installation and cable costs for all IS hazardous-area circuits

MTL830 SERIES. Cuts installation and cable costs for all IS hazardous-area circuits 830 SERIES Cuts installation and cable costs for all IS hazardous-area circuits Reduce the cost of installing hazardous-area cabling Save installation time, space and weight Highlight problems quickly

More information

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX Operator Interface for panel mounting 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 2, 22 und Division 2, can be installed in hazardous areas without additional enclosure

More information

CLIPLINE complete. The modular terminal block system for all applications

CLIPLINE complete. The modular terminal block system for all applications CLIPLINE complete The modular terminal block system for all applications CLIPLINE complete All connection technologies, one system With CLIPLINE complete, the unique modular terminal block system from

More information

9460-ET SERIES. Intrinsically Safe Ethernet Products

9460-ET SERIES. Intrinsically Safe Ethernet Products Intrinsically Safe Ethernet Products 9460-ET SERIES Today in Process Automation many different methods are used to power and to communicate with end devices. Such methods may include 4-20mA; a variety

More information

Features and Benefits. Certifications

Features and Benefits. Certifications NPort IA5000 Series 1 and 2-port serial device servers for industrial automation Features and Benefits Socket modes: TCP server, TCP client, UDP Patented ADDC (Automatic Data Direction Control) for 2-wire

More information

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX Operator Interface Operator Station 10" display, 800 x 600 pixels with resistive foil touch screen 12 function keys Zone 2, 22 and Division 2, optional GMP- compliant enclosure Data is transmitted via

More information

Level-Lance Model 5400A

Level-Lance Model 5400A Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing

More information

Safety instructions Overvoltage protection B81-35

Safety instructions Overvoltage protection B81-35 Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application

More information

HAZARDOUS AREA PTZ IP NETWORK CAMERA

HAZARDOUS AREA PTZ IP NETWORK CAMERA ZCAM4-AX HAZARDOUS AREA PTZ IP NETWORK CAMERA DS-026 Issue 02 ZIZCAM Ltd are a UK based manufacturer of CCTV Cameras for use in the Hazardous Oil, Gas and Petrochemical industries. Consequently our products

More information

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications. Safety Barriers Description Safety barriers limit the energy fed to an intrinsically safe circuit so that neither sparks nor thermal effects (hot surfaces) can cause an explosion. CEAG safety barriers

More information

Industry. WiFi communication solutions for industrial applications

Industry. WiFi communication solutions for industrial applications Industry WiFi communication solutions for industrial applications Industry WiFi networks (AP, client 3G WLg-ABOARD WLn-ABOARD WLn-RailBox WLg-xROAD WLn-xROAD AIRTRACK-D2 Typical applications Harsh environment

More information

Supplementary Components WirelessHART products

Supplementary Components WirelessHART products Overview SITRANS AW200 WirelessHART adapter The SITRANS AW200 WirelessHART adapter is a batterypowered communication component, which integrates HART and 4 to 20 ma field devices into a WirelessHART network.

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069 D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according

More information

Supplementary Components WirelessHART products

Supplementary Components WirelessHART products Overview Application The connects wireless HART field devices by radio to the Ethernet. On the radio side, the supports the WirelessHART standard and on the Ethernet side the TCP/IP and Modbus TCP communication.

More information

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12 www.stahl.de > Fieldbus connection Industrial Ethernet PROFINET, Modbus TCP or EtherNet/IP with 100 MBit/s > Redundant Ethernet connection (Modbus TCP) is possible > Explosion protected, optical inherently

More information

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring

More information

MTL8000-2/x Series Modular I/O

MTL8000-2/x Series Modular I/O -2/x Series Modular Overview Modules Modules - Overview - 2/2 components Use this option for general purpose or nonhazardous applications, or where the equipment and/or field wiring has to be mounted in

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity

More information

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology Product Data Sheet PS-001094, Rev. C September 2009 Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology The Micro Motion Model 2200S 2-wire transmitter enables the use of reliable and accurate

More information

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES O U R P R O F E S S I O N MULTIFUNCTIONAL CURRENT CONTROLLED SWITCH MODULES MAIN FEATURES 4 20 ma input Relay output Rail mountable Intrinsically safe Associated

More information

Solutions for Fossil Fuel Energy

Solutions for Fossil Fuel Energy Solutions for Fossil Fuel nergy Solutions for power plant modernization Fossil fuel generation, power plant modernization, upgrades and new installations require a wide range of electrical connectivity

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

Sensors and Systems. Short Form. that protect your plant...

Sensors and Systems. Short Form. that protect your plant... Sensors and Systems Short Form that protect your plant... About Us Who are Hansford Sensors? At Hansford Sensors, we design, develop and manufacture a wide range of high performance industrial accelerometers,

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Introduction Honeywell s STT 3000 family of microprocessor based smart temperature

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet Process Automation IS Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the problems associated with the

More information

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505 Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex

More information

Millenium II +: general characteristics

Millenium II +: general characteristics Millenium II +: general characteristics Starter kit Blind Temperature sensors Special starter kits Bare board Power supply Level detection Local extensions Accessories Standard Expandable Adjacent extensions

More information

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div. Termination Board HiCTB08-SCT-C-SC-RA Features Assembly For 8 modules V DC supply Supported signal types: DI/DO/AI/TI/AO Hazardous area: screw terminals, blue Safe area: screw terminals, black Function

More information

CPU module for zone 2 Series 9442/35

CPU module for zone 2 Series 9442/35 > Supports PROFIBUS DP, PROFINET, Modbus TCP and Ethernet/IP; incl. HART transmission > RS-485 (max. 12 Mbps) and Ethernet (max. 100 Mbps) interfaces > Extensive diagnostics based on NE 107 > Support of

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET WirelessHART components Gateway and accessories 2 Measurement made easy The ABB offering on WirelessHART accessories connect wireless sensors to the automation

More information

BA414DF Fieldbus indicator Single variable

BA414DF Fieldbus indicator Single variable FIELDBUS DISPLAYS BA4xx Series BA6xx Series Hazardous area Safe area NEW BA414DF indicator Single variable Shown with optional stainless legend plate Power Supply & Segment Coupler Host Intrinsically safe

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detecting angular positions of 0 to 360 P1-Ri-DSU35 positioning element included in delivery

More information

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET 1 Contents ETHERNET Switches ECO and Standard 3 4 SFP Modules Interface for Fiber-Optic 5 ETHERNET Switches Managed 6

More information

MC Toolkit Rugged & Intrinsically Safe models Model MCT404 Specification 34-ST , July 2017

MC Toolkit Rugged & Intrinsically Safe models Model MCT404 Specification 34-ST , July 2017 MC Toolkit Rugged & Intrinsically Safe models Model MCT404 Specification 34-ST-03-107, July 2017 Features - Configures any Honeywell DE device: SmartLine ST 3000, ST 800, ST 700 Pressure and STT 3000 Temperature

More information

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Sensors and Systems. Short Form. that protect your plant...

Sensors and Systems. Short Form. that protect your plant... Sensors and Systems Short Form that protect your plant... About us What is Hansford Sensors? At Hansford Sensors, we design, develop and manufacture a wide range of high performance industrial accelerometers,

More information

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX Panel PC for panel- mounting, quad core ATOM E3845 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 2, 22 und Division 2, can be installed in hazardous areas without

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

aentron Energy System 1 to 900 Vdc

aentron Energy System 1 to 900 Vdc aentron Energy System 1 to 900 Vdc The aentron lithium-ion energy system enables the realisation of a modular and scalable lithium-ion battery solution. The management of large lithium-ion batteries systems

More information

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2 Technical Data Communication Adapter Catalog Number 1719-AENTR I/O Module Catalog Numbers 1719-IJ, 1719-IBN8B, 1719-IF4HB, 1719-IR4B, 1719-IT4B, 1719-OB2, 1719-OB2L, 1719-CF4H Power Supply Catalog Number

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

TCS. Description. Features. IECEx. Temperature Concentrator System Multi-Channel Transmitter

TCS. Description. Features. IECEx. Temperature Concentrator System Multi-Channel Transmitter INPUT READY FAULT 1 FAULT 2 CONVERTER TCS System September 2010 Description The TCS System substantially reduces the cost of transmitting multiple temperature sensor measurements in general purpose and

More information

Conveyor Belt Alignment Switches from IDEM

Conveyor Belt Alignment Switches from IDEM Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are

More information

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S D109S INSTRUCTION MANUAL SIL Relay Output Module with Line and diagnostics DINRail Model D109S D109 SIL Relay Output Module with Line and diagnostics ISM0096 SIL Applications For Safety Related System

More information

Industrial Media Converters

Industrial Media Converters Wireless AP Industrial s Introduction & Features Fiber s Ethernet s Serial s s Distance Extension With Higher Immunity Introduction The media converters have incorporated SUNIX advanced technologies such

More information

MULTICHANNEL DATA RECORDERS

MULTICHANNEL DATA RECORDERS MULTICHANNEL DATA RECORDERS Introduction ma + V / mv RTD + - universal inputs + - TC universal inputs: RTD + TC or U + I (SRD-99) fixed inputs: RTD, TC, U, I (SRD-N16) 2 relay outputs memory up to 3 000

More information

Industrial IP67 Rated 8-Port 10/100Mbps M12 Fast Ethernet PoE Switch with Wide Operating Temperature

Industrial IP67 Rated 8-Port 10/100Mbps M12 Fast Ethernet PoE Switch with Wide Operating Temperature Industrial IP67 Rated 8-Port 10/100Mbps M12 Fast Ethernet Switch with Wide Operating Temperature In last few years, PLAET has launched various IP30 protected Industrial products which can deployed and

More information

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min. Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

SCADAPack. I/O Expansion & Communication Modules

SCADAPack. I/O Expansion & Communication Modules SCADAPack I/O Expansion & Communication Modules 1 Welcome to the SCADAPack family of I/O Expansion and Communication modules, providing flexible I/O and telemetry options. With the addition of I/O Expansion

More information

HAZARDOUS AREA DAY/NIGHT HD CAMERAS

HAZARDOUS AREA DAY/NIGHT HD CAMERAS ZCAM2 HAZARDOUS AREA DAY/NIGHT HD CAMERAS DS-021 Issue 01 ZIZCAM Ltd are a UK based manufacturer of CCTV Cameras for use in the Hazardous Oil, Gas and Petrochemical industries. Consequently our products

More information

Measurement Systems Datascan Installation and User Guide

Measurement Systems Datascan Installation and User Guide Measurement Systems Datascan Installation and User Guide Supplied By Contents Contents 1. INTRODUCTION... 1 1.1 GENERAL... 1 1.2 DATASCAN MODULE RANGE... 1 1.2.1 Measurement Processors... 1 1.2.2 Analog

More information

MGate 5102-PBM-PN Series

MGate 5102-PBM-PN Series MGate 5102-PBM-PN Series 1-port PROFIBUS-to-PROFINET gateways Features and Benefits Protocol conversion between PROFIBUS and PROFINET Supports PROFINET IO device Supports PROFIBUS DP V1 master Automatic

More information

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Data sheet 302040_en MTP300i-SIL-K Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Properties 2-wire temperature transmitter for DIN rails Galvanic isolated TC-input with cold-junction compensation

More information

Terminal Boxes Series 8118

Terminal Boxes Series 8118 > Enclosure made of glass fibre reinforced polyester resin > sizes available > Terminals and cable glands fitted to order > Enclosure design with integrated metal bracket for metal cable glands. > Degree

More information

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX Panel PC for panel- mounting, quad core ATOM E3845 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 1, 2, 21, 22 und Division 2, can be installed in hazardous areas

More information

Up to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs.

Up to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs. SA380TX-L Hardware The basic TX-L unit features: 4 digital inputs 2 analogue inputs 1 RS485 port 24v 2W auxiliary power supply GSM modem. An Ethernet port can be fitted as an option when ordering. Up to

More information

Threaded resistance thermometer Miniature design Model TR10-D

Threaded resistance thermometer Miniature design Model TR10-D Temperature Threaded resistance thermometer Miniature design Model TR10-D WIKA data sheet TE 60.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Status: Current Page 1 of 5 issue No.:1 Certificate

More information

SFY Functional Safety Frequency-to-DC Transmitter with Display

SFY Functional Safety Frequency-to-DC Transmitter with Display Functional Safety -to-dc March 2017 Description The SFY Functional Safety SIL 3 capable -to-dc is part of Moore Industries FS Functional Safety Series. It monitors frequency, period, high or low pulse

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

IOT-GATE-iMX7 Datasheet

IOT-GATE-iMX7 Datasheet IOT-GATE-iMX7 Datasheet Industrial Internet of Things Gateway Product Specification v.1.3 Capable, compact, affordable: i.mx7 Dual IoT-Gate has been designed to answer demanding IoT application requirements

More information

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch User-definable Modbus/TCP Slave addressing Supports EtherNet/IP* adapter mode Supports RESTful API for IIoT applications 2-port Ethernet

More information

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W Title INTRINSICALLY SAFE Ex ia PSU TYPE AC36W USER MANUAL Document Number 66-184-12 Issue 10 10 Update new logo and address 2017.10.18 CW CW PC 09 Added Um as 265V, Io up to 3.3A & IIB data 2017.08.21

More information

M-series Intrinsically Safe I/O

M-series Intrinsically Safe I/O DeltaV Distributed Control System Product Data Sheet M-series Intrinsically Safe I/O Features full system modularity Reduces system footprint Decreases installation time and expense Plug-and-play installation

More information

/8 DIN Universal Process Indicator

/8 DIN Universal Process Indicator Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission

More information

Stride Industrial Ethernet Switches

Stride Industrial Ethernet Switches 8-Port Ethernet Switch with Fiber Port STRIDE Industrial Ethernet Switch with eight 10/100BaseT RJ45 Ethernet ports and one 100BaseFX Fiber optic port (ST type multimode fiber connector for links up to

More information

APPLICATION GUIDE. Interface Modules IM Series.

APPLICATION GUIDE. Interface Modules IM Series. Interface Modules IM Series APPLICATION GUIDE www.turck.com Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to

More information

Backplane. System integration. Backplane

Backplane. System integration. Backplane Backplane System integration Backplane Backplanes designed for minimum overall life cycle costs Simple, reliable and professional design Using standard cost-optimised DIN-rail devices Flexible connection

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed. 2 The integrates position sensing, communication electronics, power outputs, auxiliary inputs and wire termination into a fully sealed compact package. The module also integrates a terminal strip directly

More information

10 & 18 port SNMP and Modbus/TCP Capable Ethernet Switches SEC310-2SFP-T, SEC318-2SFP-T

10 & 18 port SNMP and Modbus/TCP Capable Ethernet Switches SEC310-2SFP-T, SEC318-2SFP-T SEC310-2SFP-T SEC318-2SFP-T PRODUCT FEATURES Wide Temperature Range -40 to 75 C DIN Rail or Wall/Panel Mountable Dual 12 to 48VDC Power Inputs for Redundancy Energy Efficient Ethernet (EEE), IEEE 802.3az

More information

Backplane. Allen-Bradley. System integration. Backplane

Backplane. Allen-Bradley. System integration. Backplane Backplane System integration Allen-Bradley Backplane Backplanes designed for minimum overall life cycle costs Simple, reliable and professional design Using standard cost-optimised DIN-rail devices Flexible

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

List of Components Versions for Safetec SFT-9000 systems

List of Components Versions for Safetec SFT-9000 systems SAFETEC srl Certificate No.: 01/205/5591.00/17 Table 1a: SIL3-Certified HW Components Report-Number ST DIN-10 DIN-1007.00-XXXX ST DIN-11 DIN-1107.00-XXXX safety digital input card, 2x12 NAMUR inputs safety

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications. EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier

More information

BA448CF-F FOUNDATION fieldbus Intrinsically safe Panel mounting 8 variable Fieldbus Indicator Issue 3

BA448CF-F FOUNDATION fieldbus Intrinsically safe Panel mounting 8 variable Fieldbus Indicator Issue 3 BA448CF-F FOUNDATION fieldbus Intrinsically safe Panel mounting 8 variable Fieldbus Indicator Issue 3 Issue: 3 23 rd June 2011 2 CONTENTS 1. Description 1.1 Documentation 2. Operation 2.1 Error messages

More information