HPE NonStop X Cluster Solution Manual

Size: px
Start display at page:

Download "HPE NonStop X Cluster Solution Manual"

Transcription

1 HPE NonStop X Cluster Solution Manual Part Number: b Published: April 2017 Edition: L15.08 and subsequent L-series RVUs

2 Contents About This Document...5 Supported Release Version Updates (RVUs)... 5 Intended Audience... 5 New and Changed Information for the Edition...5 Publishing History... 5 NonStop X Cluster Solution (NSXCS) Overview... 6 Hardware Requirements for NonStop X Cluster InfiniBand (IB) Solution... 8 Technical Document for NonStop X NS7 Systems Software Overview for NonStop X Cluster Solution OSM Package Expand and Message System Traffic...11 SCF Manageability for NonStop X Cluster Solution...12 NonStop Kernel Message System Software Requirements for NonStop X Cluster Solution Installation Tasks Related Documentation Prerequisites Service Provider Required Checklist for Nodes and Connections...18 SCF Commands Cluster Connectivity Subsystem SCF Commands...19 Summary of SCF Kernel Subsystem Commands to Manage CCMON and MSGMON Processes DCTMON Subsystem SCF Commands...20 Summary of SCF Kernel Subsystem Commands to Manage the DCTMON Processes...21 Checking Operations Checking the Operation of the NonStop X Cluster Solution Using OSM to Check Operations...22 Checking the External Fabric for All Nodes Checking the Operation of Each Node Checking That Automatic Line-Handler Generation is Enabled...23 Checking CCMON, MSGMON, and DCTMON Checking the Cluster Connectivity Subsystem Checking the NonStop X Cluster Solution Configuration...24 Checking the Internal X and Y Fabrics Checking the Operation of the Expand Processes and Lines...26 Checking $NCP, $ZEXP and $ZZWAN Checking the Status of Expand-Over-IB Line-Handler Processes...26 Checking the Status of An Expand-Over-IB Line Contents

3 Changing the NonStop X Cluster Solution Topology Using OSM to Add a Node to a NonStop X Cluster Solution...28 Prerequisites for InfiniBand Cable Installation Performing the OSM Adding a Node to a NonStop X Cluster Guided Procedure...29 Performing an RVU Upgrade on a Node...29 Removing a Node From a NonStop X Cluster Solution Replacing IB Cluster Switches in a NonStop X Cluster Topology...31 Starting and Stopping Cluster Connectivity Processes and Subsystems Stopping the Cluster Connectivity Subsystem Using SCF...32 Using the OSM Service Connection...32 Stopping Expand-Over-IB Lines Starting the Cluster Connectivity Subsystem...33 Starting the External IB Fabric Starting MSGMON Starting CCMON Starting DCTMON Starting the Expand-Over-IB Line-Handler Processes and Lines...34 Websites Support and other resources...36 Accessing Hewlett Packard Enterprise Support Accessing updates...36 Customer self repair...37 Remote support Warranty information...37 Regulatory information...38 Documentation feedback Troubleshooting Using OSM to Suppress NonStop X Cluster Solution Alarms Restoring Connectivity to a Node Switching the CCMON Primary and Backup Processes...40 Starting Required Processes and Subsystems...40 Accessing SCF Help for Error Messages Fallback Procedures Fallback to a Previous RVU Fallback to Previous SPRs...42 Collecting Required After Image (AI) Information for Diagnosing Problems...42 Required AI to Troubleshoot Cluster Connectivity Issues Required AI to Troubleshoot Perceived Performance Problems...43 Required AI to Troubleshoot Process Abends Required AI to Troubleshoot Processor Halts Cables Contents 3

4 Configuring MSGMON, CCMON, and DCTMON ZCMNCONF TACL Macro...45 Run the ZCMNCONF Macro ZDCTCONF TACL Macro Run the ZDCTCONF Macro...46 Alternatively Creating an SCF Command File Configure MSGMON Configure CCMON Configure DCTMON...48 Start CCMON, MSGMON, and DCTMON...49 Expand Lines Form Contents

5 About This Document This guide describes the HPE NonStop X Cluster Solution and provides planning, installation, operations, and troubleshooting information. Supported Release Version Updates (RVUs) This publication supports the L15.08 RVU and all subsequent L-series RVUs until otherwise indicated in a replacement publication. Intended Audience This guide is written for those responsible for planning, installing, and operating a NonStop X Cluster Solution. All installation and replacement procedures related to a cluster must be performed by authorized service providers who have completed Hewlett Packard Enterprise training courses. New and Changed Information for the Edition This edition contains new information about RoCE clustering for HPE Virtualized NonStop. Publishing History Part Number Product Version Publication Date N.A. August N.A. June N.A. March 2017 About This Document 5

6 NonStop X Cluster Solution (NSXCS) Overview The NonStop X Cluster Solution provides clustering to: HPE Integrity NonStop X NS7 systems (zones) in interconnected zone topologies. These interconnected zones use InfiniBand (IB) to pass information between nodes functioning as one large processing entity and topology. For optimal fault tolerance, each node is connected along each of two IB fabrics (X and Y). Virtualized NonStop in interconnected zone topologies. These interconnected zones use RDMA over Converged Ethernet (RoCE) for fabric connectivity of data traffic between Virtualized NonStops and Virtualized CLIMs. For optimal fault tolerance, each RoCE cluster is connected along each of two RoCE fabrics (X and Y). Table 1: Features of NonStop X System IB Clusters Supported system type Supported RVU Cluster Connectivity subsystem for cluster monitoring and operations Expand-over-IB clustering option Supported zone configurations Maximum total nodes for zone configurations NonStop X IB cluster switches per zone (a zone is comprised of node(s) and an HPE NonStop X IB cluster switch pair) Maximum distance between a node and an IB cluster switch Maximum distance between IB cluster switches without IB link extenders Maximum distance between NS7 nodes in same zone Maximum distance between NS7 nodes in different zones NS7 L15.08 and later for NS7 X1 and long-haul topology L16.05 and later for NS7 X2 Managed and monitored by the Cluster Connectivity monitor (CCMON) process Expand-over-IB coexists with Expand-over-IP 1 zone referred to as single-zone or 2 or 3 zones referred to as multi-zone 3 zones is the maximum 24 nodes maximum 24 nodes can be in 1, 2, or 3 zones Two are required for each zone; one switch for each IB fabric to ensure fault tolerance 30 meters 30 meters 60 meters (short-haul interzone) 90 meters (short-haul intrazone) Table Continued 6 NonStop X Cluster Solution (NSXCS) Overview

7 Maximum distance between NonStop X IB cluster switches with IB link extenders and DWDMs Provides parallel implementation of frequently used $ZNUP functionality 65 kilometers (long-haul topology) Via the Parallel Remote Destination Control Table Monitor (DCTMON) process Table 2: Features of Virtualized NonStop RoCE Clusters Supported system Supported RVUs for RoCE clustering Cluster Connectivity subsystem for cluster monitoring and operations Expand-over-IB clustering option Supported zone configurations Maximum total zones for zone configurations Maximum distance between a node and an RoCE switch Maximum distance between zones Virtualized NonStop L17.02 and later Managed and monitored by the Cluster Connectivity Monitor (CCMON) process Expand-over-IB coexists with Expand-over-IP Consult your HPE representative Consult your HPE representative 100 meters (at a 406 bps data rate) Consult your HPE representative Long haul support Not supported for L17.02 Provides parallel implementation of frequently used $ZNUP functionality Monitor (DCTMON) process NOTE: For information about clustering the HPE Integrity NonStop NS7 CG X2 system, contact your HPE representative. That topology is not documented in this manual. NonStop X Cluster Solution (NSXCS) Overview 7

8 CAUTION: All procedures in this manual must be performed by authorized service providers. Hardware Requirements for NonStop X Cluster InfiniBand (IB) Solution HPE NonStop X IB Cluster Switch The NonStop X IB Cluster switch is an InfiniBand FDR 36-port managed switch. A pair of NonStop X IB cluster switches is required and form the foundation of each zone in the topology. These NonStop X IB cluster switches connect each node within a zone along one fabric. Every node connects to the NonStop X Cluster Solution through a pair of 4X FDR InfiniBand links (one link per fabric). Each node has up to 56 Gbps bidirectional bandwidth per fabric. The connections are through copper cables or active optical cables with QSFP transceiver. NS7 System Internal Blade IB Switch Ports 1-8 and ports 9-16 in the internal Blade IB switch are used for Cluster I/O Module (CLIM) direct connections. Port 17 is reserved for NonStop Application Direct Interface (NSADI). Port 18 is used for IB clustering with NonStop X IB cluster switches. More information Technical Document for NonStop X NS7 Systems on page 10 Replacing a NonStop Blade IB Switch, NonStop IO Expansion IB Switch, or NonStop IB Cluster Switch in a NonStop X System (service providers only) NonStop X NS7 Planning Guide IB Link Extenders for Long-Haul Topology The NonStop X Cluster long-haul topology requires customer-supplied, third-party IB link extenders. Link extenders implement the appropriate buffering and credit extension logic for long-haul links. An example topology is shown below. For information about link extenders, refer to the third-party documentation that comes with the product. 8 Hardware Requirements for NonStop X Cluster InfiniBand (IB) Solution

9 Dense Wavelength Division Multiplexers (DWDM) for Long-Haul Topology If one or more of these conditions apply, the NonStop X Cluster long-haul topology requires third-party DWDMs or optical multiplexers: Distance between cluster zones is greater than what is supported by the link extender WAN optical transceivers. Access to long-haul is through DWDM channels leased from a telecommunications provider. Desire to use optical multiplexing to lower costs (for example, share long-haul links with other data traffic such as Ethernet or Fibre Channel). For information about the DWDMs, refer to the third-party documentation that comes with the product. An example topology is shown below. NonStop X Cluster Solution (NSXCS) Overview 9

10 Hardware Requirements for RoCE Clustering for Virtualized NonStop The requirements for RoCE clustering are: RoCE clustering on Virtualized NonStop requires the use of 40 Gpbs RDMA over Converged Ethernet (RoCE) switches. For L17.02, switches used for RoCE clustering do not support a long-haul topology. Technical Document for NonStop X NS7 Systems Each new NS7 system includes a detailed Technical Document that provides information about the nodes in the NonStop X Cluster Solution topology such as: Rack included with the system and each enclosure installed in the rack Rack U location at the bottom edge of each enclosure Each cable with source, destination, connector type, cable part number, and connection labels 10 Technical Document for NonStop X NS7 Systems

11 TIP: It is important to retain all NS7 system records in an Installation Document Packet, including the Technical Document for your system and any configurations forms. To add CLIM configuration forms to the packet, ask your service provider to copy and complete the forms in the CLuster I/O Module (CLIM) Installation and Configuration Manual (L15.02+) Technical Document for Virtualized NonStop RoCE Cluster Switches NOTE: There is no technical document for Virtualized NonStop system hardware, including RoCE switches. Software Overview for NonStop X Cluster Solution OSM Package on page 11 Expand and Message System Traffic on page 11 SCF Manageability for NonStop X Cluster Solution on page 12 Cluster Connectivity Subsystem on page 12 NonStop Kernel Message System on page 14 Software Requirements for NonStop X Cluster Solution on page 14 OSM Package The HPE Open System Management (OSM) product is the primary manageability tool for the NonStop X Cluster Solution. OSM works together with the Cluster Connectivity subsystem and the Cluster Endpoint Database (CEPDB) to manage the topology. Once your service provider has verified your NonStop X Cluster Solution topology using Prerequisites on page 16, the service provider will log onto the OSM Service Connection and use the Adding a Node to NonStop X Cluster guided procedure and its online help to create your configuration. Expand and Message System Traffic In a NonStop X Cluster Solution, Message-System traffic flows directly between processors by way of the Message System but under the control of Expand. As of the L15.08 RVU, the Expand product supports the option called Expand-over-IB for NS7 systems participating in a NonStop X Cluster Solution topology. Beginning with the L17.02 RVU, the Expand-over-IB line handler applies to both NonStop X IB clusters and Virtualized NonStop RoCE clusters. This option provides high-performance inter-node communication with minimal processor cost and message latencies. This illustration diagrams the Message System traffic. Note that for L17.02 and later, Expand-over-IP is needed to connect NonStop X InfiniBand clusters with Virtualized NonStop RoCE clusters. Software Overview for NonStop X Cluster Solution 11

12 Secure Message System traffic between processes on different nodes travels through the Expand-over-IB line handlers, and through the local message system between the communicating processes and the line handlers. Nonsecure message-system traffic flows directly between processors through the intersystem Message System connections as directed by the Network Routing Table (NRT) under the control of Expand. The intersystem Message System connections are not used if the appropriate settings are not made in the NRT. SCF Manageability for NonStop X Cluster Solution You can use the Subsystem Control Facility (SCF) to configure, control, and display information about configured objects within each subsystem. Each subsystem responds to and processes SCF commands that affect that subsystem. For more information about the SCF commands refer to SCF Commands on page 19. The NonStop X Cluster Solution uses the new Cluster Connectivity Subsystem on page 12 and also introduces the DCTMON subsystem on the L-series RVUs. Both are configured and controlled using SCF commands. Note, however, that OSM is the primary manageability tool for the NonStop X Cluster Solution. Cluster Connectivity Subsystem The Cluster Connectivity subsystem manages and monitors NonStop X Cluster Solution operations on each node. Nodes join and leave the NonStop X Cluster when you start and stop Cluster Connectivity services on the nodes. Each node monitors its own connectivity with other nodes in the NonStop X Cluster. The identifiers for the subsystem are: Cluster Connectivity Subsystem Identifiers CMN ZCMN Function CMN is the mnemonic name for the subsystem and appears in event identifiers such as: TANDEM.CMN.L01. Appears at the beginning of EMS event token names such as: ZCMN-EVT-NODISCOVERY. Table Continued 12 SCF Manageability for NonStop X Cluster Solution

13 Cluster Connectivity Subsystem Identifiers $ZZCMN $ZZKRN.#ZZCMN Function Process name for the CCMON process pair (see CCMON following). $ZZCMN is the Cluster Connectivity subsystem monitor process. Generic process name of the Cluster Connectivity subsystem monitor process as configured under $ZZKRN. CCMON, MSGMON, and DCTMON Descriptions This table describes the NonStop X Cluster Solution processes supported on L15.08 and later. If these processes are started on L15.02, they generate a version mismatch EMS message and gracefully terminate. For information on configuring and starting these processes, refer to Configuring MSGMON, CCMON, and DCTMON on page 45. CCMON CCMON is a persistent process pair and is the focal point for NonStop X Cluster Solution management and monitoring. Function Subsystem Programmatic Interface (SPI) server for subsystem management commands. Monitors and responds to cluster-related events. Exists on every node in a NonStop X cluster. Can be replaced without requiring a system load. If it fails on a system with two processors or more, a new CCMON process pair is immediately started by the Persistence Manager process ($ZPM). Supports PTRACE for analysis of internal CCMON and MSGMON traces. MSGMON is bundled with CCMON. CCMON must be configured and started before adding a node to the NonStop X Cluster Solution. MSGMON The Message System Monitor (MSGMON) process is a monitor process that resides in each processor and executes various cluster-related functions required by the Message System. Function Helper for the CCMON subsystem monitor Handles communications between the primary CCMON and individual processors Can be replaced without requiring a system load Runs with a process name of $ZIMnn in each CPU, where nn is the CPU number. MSGMON must be configured and started before adding a node to the NonStop X Cluster Solution. Table Continued NonStop X Cluster Solution (NSXCS) Overview 13

14 DCTMON 1 The Parallel Remote Destination Control Table Monitor process (DCTMON) improves the performance of remote DCT access operations. These operations typically precede remote file open operations. Function Implements a subset of the remote DCT access operations supported by the Network Utility Process ($ZNUP). Provides a parallel implementation of frequently used $ZNUP functionality. Handles incoming remote DCT access requests sent directly via the NonStop X Cluster Solution without involving Expandover-IB line handlers. Runs with a process name of $ZDMnn in each CPU, where nn is the CPU number. 1 Unlike CCMON and MSGMON, DCTMON processes are not required to establish connectivity among nodes in a NonStop X Cluster Solution. DCTMON processes implement an optimization that improves the performance of certain cluster operations such as remote file opens. NonStop Kernel Message System The Message System provides the same set of privileged Application Programming Interfaces (APIs) for inter-processor communication between processes residing on the same or on a different node. The Message System implements a common communication protocol stack to exchange messages between processors in the same node or between different nodes connected via the NonStop X Cluster Solution. Software Requirements for NonStop X Cluster Solution The software products below are required and must have these minimum release levels. Table 3: Software for NonStop X Cluster Solution (L15.08 and later L-Series RVUs) Software Component Software Required Minimum Expand-over-IB profile T0958 T0958 L02 CCMON/MSGMON T0942 T0942 L01 DCTMON T1000 T1000 L02 OSM Service Connection Suite T0682 T0682 L02 InfiniBand (IB) Cluster License T0953 T0953 L T0953L01 is required for L15.08 and L16.05 only. For L17.02 and later L-series RVUs, cluster licensing is consolidated in the core license and T0953L02 is required. Refer to the NonStop Core Licensing Guide for details. 14 NonStop Kernel Message System

15 Table 4: Software for RoCE Cluster on Virtualized NonStop (L17.02 and later RVUs only) Software Component Software Required Minimum Expand-over-IP profile T0958 T0958 L02 CCMON/MSGMON T0942 T0942 L01^AAB DCTMON T1000 T1000 L02 OSM Service Connection Suite T0682 T0682 L02^BAI NOTE: For information about NonStop core licensing for NonStop X systems and Virtualized NonStop systems, see the latest edition of the NonStop Core Licensing Guide. In addition to the products above: The NonStop X Cluster Solution must be enabled in the core license. T0953 with a minimum version T0953L02 must be installed for Virtualized NonStop and RoCE clusters. NonStop X Cluster Solution (NSXCS) Overview 15

16 Installation Tasks CAUTION: Only HPE authorized service providers can perform the procedures described in this manual. Related Documentation OSM Adding a Node to a NonStop X Cluster Guided Procedure online help or the PDF version of this online help available on Servce Access Workbench (SAW) NonStop X NS7 Planning Guide Virtualized NonStop Deployment and Configuration Guide Prerequisites Service providers, before adding the first node or subsequent nodes to a NonStop X Cluster Solution zone, you must verify these pre-requisites are met. Service Providers must verify that all nodes that are being added meet these prerequisites In L17.02 and later L-series RVUs: NonStop X Cluster Solution must be enabled in the core license. In lieu of clustering enablement in the core license, each node may use the T0953 license described below. If clustering is not enabled in the core license, contact the license manager help desk (license.manager@hpe.com) to request a new license. In L15.08 and L16.05, each node requires an installed NonStop X Cluster license file (T0953). The license file is in either of these subvolumes: $SYSTEM.SYSTEM or $SYSTEM.SYSnn If the NonStop X Cluster license file is not installed, it must be ordered from QMS, and copied to either of the above subvolumes. Software Requirements for NonStop X Cluster Solution on page 14 must be met. If software installation is required on any nodes, follow all the installation instructions in each SPR's softdoc to install the SPR on the nodes. L15.08 or later is required for InfiniBand clustering. L17.02 is required for Virtualized NonStop RoCE clustering. Table Continued 16 Installation Tasks

17 Service Providers must verify that all nodes that are being added meet these prerequisites The hardware requirements described in Hardware Requirements for NonStop X Cluster InfiniBand (IB) Solution on page 8 or Hardware Requirements for RoCE Clustering on page 11 for Virtualized NonStop must be met. All required cables for the customer s cluster configuration must be on hand. If necessary, order the required switches and cables. Service providers: Refer to the QMS tech doc for specific details of the customer s configuration including connections and cable types. CAUTION: For InfiniBand clusters only, do not connect any InfiniBand cables. To avoid outages, InfiniBand cabling steps must be followed very carefully under the guidance of the OSM Add Note to NonStop X Cluster guided procedure. Expand manager process ($ZEXP) and the network control process ($NCP) must be started in the nodes. Check the status of these processes by using TACL commands: STATUS $ZEXP STATUS $NCP Ensure that $ZZWAN is running. You can check the $ZZWAN process status by using this TACL command: STATUS $ZZWAN TIP: This prerequisite only applies if you are manually configuring Expand-over-IB lines. Skip this if you prefer to use OSM Automatic Line Handler Configuration. Expand-over-IB lines are planned for each node to be added. When planning these lines, make sure that these defaults are appropriate for your installation: The default prefix used to name the line-handler processes The default CPU assignment for each line-handler process Proceed to Service Provider Required Checklist for Nodes and Connections on page 18 Installation Tasks 17

18 Service Provider Required Checklist for Nodes and Connections CAUTION: For InfiniBand clusters only, the service provider must review important documentation and carefully follow InfiniBand cabling instructions prior to adding nodes to an InfiniBand cluster. Review Checking the Operation of Each Node on page 22 before adding nodes and after adding nodes to an InfiniBand cluster. To ensure cluster connectivity, service providers need to review the online help within the OSM Adding a Node to a NonStop X Cluster guided procedure or the PDF version of this online help available on SAW, Adding a Node to a NonStop X Cluster Guided Procedure. CAUTION: For InfiniBand clusters only, do not connect the InfiniBand fiber-optic cables until the Adding a Node to a NonStop X Cluster guide procedure instructs you to do so. All connections must be made one fabric at a time. Failure to adhere to these cautions could result in serious InfiniBand cluster problems. Perform the Adding a Node to a NonStop X Cluster guided procedure and then return to this manual as needed. Determine if the automatic line-handler configuration is enabled in the nodes: Check for the presence of $ZZKRN.#OSM-CONFLH-RD. If it is present, the automatic line-handler configuration is enabled. Check the status of the routing distributor ($ZOLHD). If this process is running, automatic linehandler configuration is enabled. Although the routing distributor is running, the #OSM- CONFLH-RD process remains in a STOPPED state. 18 Service Provider Required Checklist for Nodes and Connections

19 SCF Commands This chapter describes the SCF commands for three separate subsystems: Cluster Connectivity Subsystem SCF Commands on page 19 Summary of SCF Kernel Subsystem Commands to Manage CCMON and MSGMON Processes on page 19 for managing the CCMON and MSGMON processes DCTMON Subsystem SCF Commands on page 20 Cluster Connectivity Subsystem SCF Commands You can use SCF to manage the Cluster Connectivity subsystem. The SCF command interface for the Cluster Connectivity subsystem is simpler with fewer options than in cluster subsystems found in RVUs prior to L-series RVUs. You can also use the OSM Service Connection to manage the Cluster Connectivity subsystem. For DCTMON subsystem commands, refer to DCTMON Subsystem SCF Commands on page 20. You must be running the L15.08 RVU or later to access Cluster Connectivity SCF commands. To access the help for Cluster Connectivity SCF commands, type SCF HELP CMN. This tables lists the supported commands for the Cluster Connectivity subsystem. Table 5: Supported SCF Commands for Cluster Connectivity Subsystem Command \ Object Type NULL PROCESS SUBNET SUBSYS CONN ALTER INFO X X PRIMARY X START X STATUS X X X STOP X TRACE X VERSION X X X X X X = The command currently supports this object type. Summary of SCF Kernel Subsystem Commands to Manage CCMON and MSGMON Processes This table summarizes the commands by the action performed and the command s syntax. Type SCF HELP KERNEL PROCESS for more information on NonStop Kernel subsystem commands. SCF Commands 19

20 If you want to View the configuration attributes of the $ZZCMN process pair Alter the configuration attributes of the $ZZCMN process pair Start the $ZZCMN process pair Stop the $ZZCMN process pair View the configuration attributes of the MSGMON process Alter the configuration attributes of the MSGMON process Start the $ZIMnn MSGMON processes Stop the $ZIMnn MSGMON processes Use this command SCF INFO PROCESS $ZZKRN.#ZZCMN,DETAIL SCF ALTER PROCESS $ZZKRN.#ZZCMN SCF START PROCESS $ZZKRN.#ZZCMN SCF ABORT PROCESS $ZZKRN.#ZZCMN SCF INFO PROCESS $ZZKRN.#MSGMON,DETAIL SCF ALTER PROCESS $ZZKRN.#MSGMON SCF START PROCESS $ZZKRN.#MSGMON SCF ABORT PROCESS $ZZKRN.#MSGMON For information on configuring the $ZZCMN and $ZIMnn processes using the preferred TACL macro method, refer to Configuring MSGMON, CCMON, and DCTMON on page 45. DCTMON Subsystem SCF Commands NOTE: For more details on the DCTMON functionality, refer to Support Note S14037: Introduction of Product T1000 DCTMON. DCTMON is also supported on J- and H-series RVUs. The DCTMON processes ($ZDMnn) must be started before DCTMON SCF commands can be processed. To access the help for DCTMON SCF commands, type SCF HELP DCT. This table lists the supported DCTMON subsystem SCF commands. Table 6: Supported SCF Commands for DCTMON Subsystem Command \ Object Type NULL PROCESS STATS TRACE X X VERSION X X X = The command currently supports this object type. 20 DCTMON Subsystem SCF Commands

21 Summary of SCF Kernel Subsystem Commands to Manage the DCTMON Processes This table summarizes the commands by the action performed and the command s syntax. Type SCF HELP KERNEL PROCESS for more information on NonStop Kernel subsystem commands. If you want to View the configuration attributes of the DCTMON process Alter the configuration attributes of the DCTMON process Start the $ZDMnn DCTMON processes Stop the $ZDMnn DCTMON processes Use this command SCF INFO PROCESS $ZZKRN.#DCTMON,DETAIL SCF ALTER PROCESS $ZZKRN.#DCTMON SCF START PROCESS $ZZKRN.#DCTMON SCF ABORT PROCESS $ZZKRN.#DCTMON For information on configuring the $ZDMnn process using the preferred TACL macro method, refer to Configuring MSGMON, CCMON, and DCTMON on page 45. Summary of SCF Kernel Subsystem Commands to Manage the DCTMON Processes 21

22 Checking Operations This chapter provides procedures for checking the operations of the NonStop X Cluster Solution in a NonStop X InfiniBand cluster or a Virtualized NonStop RoCE cluster. Checking the Operation of the NonStop X Cluster Solution From each node in a NonStop X InfiniBand cluster or Virtualized NonStop RoCE cluster, check the operation of the NonStop X Cluster Solution as soon as you complete any of these procedures: Installing a node Replacing a NonStop X Cluster IB switch or Virtualized NonStop RoCE switch Replacing a switch within a node Using OSM to Check Operations You can use the OSM Service Connection and associated online help to quickly check the health of each switch and node in the NonStop X Cluster Solution. If you find problems with a node, resolve the problems before adding additional nodes to the NonStop X Cluster Solution. Checking the External Fabric for All Nodes Perform this procedure after: Installing a node in an InfiniBand or RoCE cluster Replacing a NonStop X Cluster IB switch or Virtualized NonStop RoCE switch Replacing a switch within a node NOTE: You must configure remote passwords before you can use the STATUS SUBNET $ZZCMN, PROBLEMS command to gather information about remote nodes. Use SCF to check if direct communication is possible on both fabrics between all nodes in the cluster. This command queries the CCMON processes in all nodes, and displays whether connectivity along the X and Y fabrics is up for each node. You do not have to issue separate commands for each node. 1. Log on to any node and check for connectivity problems in the cluster: STATUS SUBNET $ZZCMN, PROBLEMS 2. For each node that should be active, verify that the display shows No connectivity problems detected. 3. If the display shows a list of nodes next to a particular node, a problem has occurred with the connection between that node and the nodes in the list. In that case, issue SCF STATUS SUBNET $ZZCMN in each problem node to get more details about the connectivity issues affecting those nodes. For more details on SCF STATUS SUBNET $ZZCMN command options, type SCF HELP CMN STATUS SUBNET. Checking the Operation of Each Node The topics in this section describe operation tasks before and after a node installation. Checking That Automatic Line-Handler Generation is Enabled on page 23 Checking CCMON, MSGMON, and DCTMON on page 23 Checking the Cluster Connectivity Subsystem on page Checking Operations

23 Checking the NonStop X Cluster Solution Configuration on page 24 Checking the Internal X and Y Fabrics on page 25 Checking the Operation of the Expand Processes and Lines on page 26 Checking the Status of Expand-Over-IB Line-Handler Processes on page 26 Checking the Status of An Expand-Over-IB Line on page 27 Checking That Automatic Line-Handler Generation is Enabled Use one of these methods to determine if the automatic line-handler generation is enabled in the nodes: Check for the presence of $ZZKRN.#OSM-CONFLH-RD by entering SCF INFO PROCESS $ZZKRN.#OSM-CONFLH-RD. If it is present, the automatic line-handler configuration is enabled. Check the status of the routing distributor ($ZOLHD). If this process is running (but in a STOPPED state), automatic line-handler configuration is enabled. Although the routing distributor is running, the #OSM-CONFLH-RD process remains in a STOPPED state. Checking CCMON, MSGMON, and DCTMON NOTE: Unlike CCMON and MSGMON, DCTMON processes are not required to establish connectivity among nodes in a NonStop X Cluster Solution. DCTMON processes implement an optimization that improves the performance of certain cluster operations such as remote file opens. For more information about DCTMON, refer to CCMON, MSGMON, and DCTMON Descriptions on page 13. Perform this procedure: Before adding a node to a NonStop X Cluster Solution If you cannot start the Cluster Connectivity subsystem If you cannot connect to a remote node If you cannot display information about the NonStop X Cluster Solution in the OSM Service Connection To avoid conflicts with OSM and the guided procedures, you must configure $ZZKRN.#ZZCMN, $ZZKRN.#MSGMON, and $ZZKRN.#DCTMON to be the symbolic names for CCMON, MSGMON, and DCTMON, respectively. Use the SCF interface to the Kernel subsystem to check that these processes are configured correctly and in the STARTED state: 1. Display a list of all currently configured generic processes: INFO PROCESS $ZZKRN.* 2. Check that the CCMON, MSGMON, and DCTMON processes are displayed in the *Name column with these required SCF symbolic names: Checking That Automatic Line-Handler Generation is Enabled 23

24 Program File Name Process Name Required SCF Symbolic Name CCMON $ZZCMN $ZZKRN.#ZZCMN MSGMON $ZIMnn $ZZKRN.#MSGMON DCTMON $ZDMnn $ZZKRN.#DCTMON 3. If the processes are not configured with the required names, configure each process as described in Configuring MSGMON, CCMON, and DCTMON on page Check that CCMON, MSGMON, and DCTMON are configured correctly: INFO PROCESS $ZZKRN.#ZZCMN, DETAIL INFO PROCESS $ZZKRN.#MSGMON, DETAIL INFO PROCESS $ZZKRN.#DCTMON, DETAIL Compare the configured modifiers for CCMON, MSGMON, and DCTMON with the recommended modifiers shown in Configuring MSGMON, CCMON, and DCTMON on page Check that the processes are started: STATUS PROCESS $ZZKRN.#ZZCMN STATUS PROCESS $ZZKRN.#MSGMON STATUS PROCESS $ZZKRN.#DCTMON 6. If any of these are not started, refer to Starting and Stopping Cluster Connectivity Processes and Subsystems on page 32. Checking the Cluster Connectivity Subsystem At an SCF prompt, type the following command to check if the Cluster Connectivity subsystem is started on the node: STATUS SUBSYS $ZZCMN If necessary, issue the SCF START SUBSYS $ZZCMN command to start the Cluster Connectivity subsystem in the node. Checking the NonStop X Cluster Solution Configuration The SCF STATUS CONN $ZZCMN command displays the status of the local node's connections to the IB cluster fabrics and displays the same values whether or not the DETAIL option is specified. At an SCF prompt, type the following command to check the configuration of the NonStop X Cluster Solution: SCF STATUS CONN $ZZCMN An example display of this command for a NonStop X system node using the L-series RVUs L15.08 through L16.05 is as follows: \TEST.$SYSTEM.SYSTEM> SCF STATUS CONN $ZZCMN STATUS CONNECTION IB Cluster Configured Expand Node Number 101 IB Cluster License File 24 Checking the Cluster Connectivity Subsystem

25 $SYSTEM.SYS01.ZLT953IB The status fields for the STATUS CONN display are: IB Cluster Indicates if the local node is configured for connectivity to a cluster. Expand Node Number Identifies the Expand node number of the node. IB Cluster License File Lists the location of the T0953 license file on the local node that authorizes clustering. This cluster licensing method has been supported since the L15.08 RVU. However, beginning with L17.02, it is preferred that cluster licensing be provided through core licensing. An example display of this command for those using the L17.02 RVU or later is as follows: \TEST.$SYSTEM.SYSTEM> SCF STATUS CONN $ZZCMN STATUS CONNECTION Clustering Configured Expand Node Number 63 Cluster License File $SYSTEM.SYS01.ZLT953IB Cluster Enablement in Core License Yes The status fields for the STATUS CONN display are: Clustering Indicates if the local node is configured for connectivity to a cluster. Expand Node Number Identifies the Expand node number of the node. Cluster License File Lists the location of the T0953 license file on the local node that authorizes clustering. This cluster licensing method has been supported since the L15.08 RVU. However, beginning with L17.02, it is preferred that cluster licensing be provided through core licensing. Cluster Enablement in Core License Indicates whether clustering is enabled in the core license. This cluster licensing method is first supported starting with the L17.02 RVU. Checking the Internal X and Y Fabrics If a problem occurs on an internal fabric on any node in a NonStop X IB cluster, check if OSM shows any alarms on internal Blade IB switches and NonStop X system processors on the problem node. To check the fabric s status, you can use the SCF STATUS FABRIC $ZFAB command. Checking the Internal X and Y Fabrics 25

26 Checking the Operation of the Expand Processes and Lines NOTE: Expand over-ib line-handler processes and lines are used in both IB and RoCE clusters. $NCP, $ZEXP, and $ZZWAN must be running before you add a node to a NonStop X Cluster Solution topology. The Expand-over-IB line-handler processes and lines are configured and started after the node is added. Checking $NCP, $ZEXP and $ZZWAN Perform this procedure before running the OSM Adding a Node to a NonStop X Cluster guided procedure. Process TACL Name Required SCF Symbolic Name Expand manager $ZEXP $ZZKRN.#ZEXP Network control process $NCP Not applicable WAN subsystem manager process $ZZWAN $ZZKRN.#ZZWAN 1. Check that $ZEXP, $NCP, and $ZZWAN are started. At a TACL prompt: STATUS $ZEXP STATUS $NCP STATUS $ZZWAN 2. Check that the $NCP ALGORITHM modifier is set to the same value on all nodes and on all Expand nodes that communicate with the NonStop X Cluster Solution. At an SCF prompt: INFO PROCESS $NCP, DETAIL If these processes are not properly configured or not started, refer to the Expand Configuration and Management Manual. Checking the Status of Expand-Over-IB Line-Handler Processes Perform this procedure after you have added a node to a NonStop X Cluster Solution or if you cannot start an Expand-over-IB line. NOTE: Expand-over-IB applies to both NonStop X IB Clusters and RoCE clusters. To check the status of the line-handler processes, either: At an SCF prompt, type: STATUS DEVICE $ZZWAN.* Perform the Add Node to NonStop X Cluster action to determine if lines are configured and the state of the lines. For more information, see the Adding a Node to a NonStop X Cluster Guided Procedure online help. 26 Checking the Operation of the Expand Processes and Lines

27 Checking the Status of An Expand-Over-IB Line NOTE: You can also check the status of an Expand-over-IB line using OSM. For details, see the OSM online help. Perform this procedure after you have added a node or if you are having problems with an Expand-over- IB line. NOTE: Expand-over-IB applies to both NonStop X IB clusters and RoCE clusters. 1. To list the Expand-over-IB lines: LISTDEV TYPE 63,7 The naming convention for Expand-over-IB lines is $IB<Expand node number>. For example, $IB035 is the Expand-over-IB line to Expand node number Check that the line is started and ready: STATUS LINE $IB035, DETAIL 3. Check that the path is started: STATUS PATH $IB035, DETAIL 4. For additional information about the lines: INFO PROCESS $NCP, NETMAP 5. If a line is STOPPED, NOT READY, or not in a STARTED state, issue SCF STATUS SUBNET $ZZCMN to verify if connectivity to the remote node is up, and then start the line. For example: START LINE $IB035 Checking the Status of An Expand-Over-IB Line 27

28 Changing the NonStop X Cluster Solution Topology CAUTION: Only authorized service providers can perform the procedures described in this manual. Service providers can use these procedures to make changes to an already installed NonStop X Cluster Solution: Using OSM to Add a Node to a NonStop X Cluster Solution on page 28 Performing an RVU Upgrade on a Node on page 29 Removing a Node From a NonStop X Cluster Solution on page 30 Replacing IB Cluster Switches in a NonStop X Cluster Topology on page 31 Using OSM to Add a Node to a NonStop X Cluster Solution This table describes the OSM action that is used for adding a node to a NonStop X Cluster. OSM Action Add Node to NonStop X Cluster 1 Function Launches the Adding a NonStop X Cluster guided procedure. Indicates whether or not line-handler processes are configured between the local node and remote nodes and shows the line states. Allows you to configure and start Expand-over-IB line-handler processes and Expand-over-IB lines from the local node to all remote nodes. Indicates when to connect the fiber-optic cables between the nodes and the NonStop X IB Cluster switches. Prompts you to start Cluster Connectivity cluster services by placing the NonStop X Cluster Solution SUBSYS object in the STARTED state and collects cluster information. Configures the Cluster Endpoint Database (CEPDB) in each node in the cluster. 1 IMPORTANT: This OSM action has required Prerequisites for InfiniBand Cable Installation on page Changing the NonStop X Cluster Solution Topology

29 Prerequisites for InfiniBand Cable Installation Service providers must ensure these prerequisites are met: All required planning tasks for adding a node are met. Refer to Prerequisites on page 16 and Service Provider Required Checklist for Nodes and Connections on page 18. Install the InfiniBand cabling one fabric at a time, after the Tech Doc has been carefully reviewed. CAUTION: Do not connect the InfiniBand fiber-optic cables until the guided procedure instructs you to do so. You have carefully reviewed the instructions in the Adding a Node to a NonStop X Cluster Guided Procedure online help or the PDF version of this help, Adding a Node to a NonStop X Cluster Guided Procedure, located on SAW. It is also advised that you have the online help or the PDF open during the procedure. Once all these prerequisites are met, proceed to Performing the OSM Adding a Node to a NonStop X Cluster Guided Procedure on page 29. Performing the OSM Adding a Node to a NonStop X Cluster Guided Procedure 1. In the tree pane of the OSM Service Connection, select the System object. Right-click and select Actions. 2. From the available actions drop-down list, select the Add Node to NonStop X Cluster. 3. Click Perform Action. Ensure you are using the documentation referred to in Prerequisites for InfiniBand Cable Installation on page 29. CAUTION: Do not connect the InfiniBand fiber-optic cables until the Adding a Node to a NonStop X Clusterguided procedure instructs you to do so. 4. In the guided procedure, click Start. Performing an RVU Upgrade on a Node This procedure describes the steps for an RVU upgrade in a node connected to the NonStop X Cluster Solution. TIP: Besides the RVU upgrade itself, this procedure: Minimizes EMS error messages on other nodes connected to the same cluster. Minimizes error-handling software overhead in other nodes connected to the same cluster, such as message retries to the node receiving the RVU upgrade. Allows for a graceful communication shut down to/from the node receiving the RVU upgrade. To perform an RVU upgrade on a node: Prerequisites for InfiniBand Cable Installation 29

30 1. Record the Expand-over-IB lines to be stopped. Refer to Expand Lines Form on page Shut down any applications using Expand-over-IB connections between the node and the rest of the cluster. 3. Stop the Expand-over-IB lines. Refer to Stopping Expand-Over-IB Lines on page On the node that will receive the RVU upgrade, stop the Cluster Connectivity subsystem. Refer to Stopping the Cluster Connectivity Subsystem on page Perform the RVU upgrade. 6. After the system load of the new RVU, issue these SCF commands to verify the $ZZCMN, $ZIMnn, and $ZDMnn (if present) processes are started: STATUS PROCESS $ZZKRN.#ZZCMN STATUS PROCESS $ZZKRN.#MSGMON STATUS PROCESS $ZZKRN.#DCTMON The above processes should start automatically after system load if they were configured as described in Configuring MSGMON, CCMON, and DCTMON on page 45. Otherwise, you can start these processes manually as described in Starting MSGMON on page 34, Starting CCMON on page 34, and Starting DCTMON on page To confirm that the Cluster Connectivity subsystem is started on the node that received the RVU upgrade, issue the SCF command: STATUS SUBSYS $ZZCMN 8. The Cluster Connectivity subsystem should start automatically after a system load, assuming the STARTSTATE attribute is configured as STARTED. For details on the STARTSTATE attribute, refer to the SCF Reference Manual for the Kernel Subsystem or type SCF HELP CMN ALTER SUBSYS. a. If necessary, display the STARTSTATE attribute by issuing the SCF command: INFO SUBSYS $ZZCMN b. If necessary, manually start the Cluster Connectivity subsystem by issuing the SCF command: START SUBSYS $ZZCMN 9. To confirm that connectivity between the node that received the RVU upgrade and all other nodes in the NonStop X Cluster has been restored, issue the SCF command: STATUS SUBNET $ZZCMN NOTE: It might take a few minutes for the node that received the RVU upgrade to restore Cluster Connectivity subsystem connectivity to all other nodes. a. The STATUS SUBNET $ZZCMN command also shows the state of the Expand-over-IB lines to/from the node receiving the RVU upgrade. The Expand-over-IB lines should restart automatically if the OSM Automatic Line Handler generation feature is enabled as described in Checking That Automatic Line-Handler Generation is Enabled on page 23. b. If necessary, you can restart the previously stopped Expand-over-IB lines. Refer to Starting the Expand-Over-IB Line-Handler Processes and Lines on page 34. Removing a Node From a NonStop X Cluster Solution To remove a node from a NonStop X Cluster Solution in a NonStop X IB cluster or Virtualized Nonstop RoCE cluster: 30 Removing a Node From a NonStop X Cluster Solution

31 1. Record the Expand-over-IB lines to be stopped. Refer to Expand Lines Form on page Shut down any applications using Expand-over-IB connections between the node and the rest of the cluster. 3. From the OSM Service Connection, perform the Place Local Node in Service action on the Cluster object. This will suppress dialouts from the other nodes while the node is being removed from the cluster. 4. From the OSM Service Connection, issue the Remove Node from Cluster action on the Local Node object. This will remove the node from the Cluster Endpoint Database (CEPDB) configuration on each node in the cluster. 5. Stop the Expand-over-IB lines. Refer to Stopping Expand-Over-IB Lines on page On the node you are removing, stop the Cluster Connectivity subsystem. Refer to Stopping the Cluster Connectivity Subsystem on page Stop the $ZZCMN, $ZIMnn, and $ZDMnn processes on the node you are removing: SCF ABORT PROCESS $ZZKRN.#ZZCMN SCF ABORT PROCESS $ZZKRN.#MSGMON SCF ABORT PROCESS $ZZKRN.#DCTMON 8. Delete the $ZZCMN, $ZIMnn, and $ZDMnn processes on the node you are removing: SCF DELETE PROCESS $ZZKRN.#ZZCMN SCF DELETE PROCESS $ZZKRN.#MSGMON SCF DELETE PROCESS $ZZKRN.#DCTMON 9. Stop and delete Expand-over-IB line handler processes on the node you are removing. 10. From SCF, issue the commands WAN STOP DEVICE and HELP WAN DELETE DEVICE for more information. 11. You must disconnect the cables one fabric at a time. a. Disconnect the cable from the X fabric cluster switch. b. For a NonStop X IB cluster only, wait 1 minute before disconnecting the other cable. c. Disconnect the other cable from the Y fabric cluster switch. Replacing IB Cluster Switches in a NonStop X Cluster Topology Service providers should refer to the replacement instructions in the Replacing a NonStop Blade IB Switch, NonStop IO Expansion IB Switch, or NonStop IB Cluster Switch in a NonStop X System service procedure. Replacing IB Cluster Switches in a NonStop X Cluster Topology 31

32 Starting and Stopping Cluster Connectivity Processes and Subsystems When the Cluster Connectivity subsystem is stopped on a node, the node informs other nodes that it is leaving the NonStop X Cluster. Stopping the Cluster Connectivity subsystem destroys internode connectivity between the node that receives the command and all other nodes over both external fabrics. The NonStop X cluster monitor process $ZZCMN itself does not stop but remains an active process. Stopping the Cluster Connectivity Subsystem NOTE: Hewlett Packard Enterprise recommends that you do not stop and restart the Cluster Connectivity subsystem as a method to repair cluster connectivity. Stopping the Cluster Connectivity subsystem is normally used prior to: Physically disconnecting a node Halting the processors on a node The DSM/SCM ZPHIRNM step when installing a new release version update (RVU) Aborting the CCMON process pair for the purpose of upgrading the CCMON software, unless recommended otherwise by Hewlett Packard Enterprise Using SCF 1. At an SCF prompt, stop the Cluster Connectivity subsystem: STOP SUBSYS $ZZCMN 2. Confirm that the Cluster Connectivity subsystem is stopped: STATUS SUBSYS $ZZCMN Using the OSM Service Connection 1. Right-click the OSM Cluster object, and select Actions. 2. From the Available Actions drop-down list, select Set Cluster Subsys State. 3. Click Perform Action. 4. From the drop-down list of NonStop X cluster states, select Stopped. 5. Click OK. The Action Status window shows the progress of the action. 6. Click Close to close the Actions dialog box. 7. From the details pane, select the Attributes tab. 8. From the Attributes tab, check that the state is stopped. Stopping Expand-Over-IB Lines Stopping Expand-over-IB lines is required when you add, move, or remove a node, or when you perform an RVU upgrade on a node. Use these SCF commands to identify and stop Expand-over-IB lines and also refer to the Expand Lines Form on page For the affected node, identify the currently configured Expand-over-IB lines. For example: 32 Starting and Stopping Cluster Connectivity Processes and Subsystems

HP Certified Professional

HP Certified Professional HP Certified Professional NonStop Advanced and Communications Level 2 Exam # HP0-761 Exam Preparation Guide Check the web site for course descriptions and prerequisites at: http://education.hp.com/curr-nonstop.htm

More information

IBM Europe Announcement ZG , dated February 13, 2007

IBM Europe Announcement ZG , dated February 13, 2007 IBM Europe Announcement ZG07-0221, dated February 13, 2007 Cisco MDS 9200 for IBM System Storage switches, models 9216i and 9216A, offer enhanced performance, scalability, multiprotocol capabilities, and

More information

HPE 3PAR Remote Copy Extension Software Suite Implementation Service

HPE 3PAR Remote Copy Extension Software Suite Implementation Service Data sheet HPE 3PAR Remote Copy Extension Software Suite Implementation Service HPE Lifecycle Event Services HPE 3PAR Remote Copy Extension Software Suite Implementation Service provides customized deployment

More information

Install ISE on a VMware Virtual Machine

Install ISE on a VMware Virtual Machine Supported VMware Versions, page 1 Support for VMware vmotion, page 1 Support for Open Virtualization Format, page 2 Virtual Machine Requirements, page 3 Virtual Machine Resource and Performance Checks,

More information

Introduction to High-Speed InfiniBand Interconnect

Introduction to High-Speed InfiniBand Interconnect Introduction to High-Speed InfiniBand Interconnect 2 What is InfiniBand? Industry standard defined by the InfiniBand Trade Association Originated in 1999 InfiniBand specification defines an input/output

More information

VPLEX Networking. Implementation Planning and Best Practices

VPLEX Networking. Implementation Planning and Best Practices VPLEX Networking Implementation Planning and Best Practices Internal Networks Management Network Management VPN (Metro/Witness) Cluster to Cluster communication (WAN COM for Metro) Updated for GeoSynchrony

More information

Product Overview. Send documentation comments to CHAPTER

Product Overview. Send documentation comments to CHAPTER Send documentation comments to mdsfeedback-doc@cisco.com CHAPTER 1 The Cisco MDS 9100 Series Multilayer Fabric Switches provide an intelligent, cost-effective, and small-profile switching platform for

More information

Data Migration from Dell PS Series or PowerVault MD3 to Dell EMC SC Series Storage using Thin Import

Data Migration from Dell PS Series or PowerVault MD3 to Dell EMC SC Series Storage using Thin Import Data Migration from Dell PS Series or PowerVault MD3 to Dell EMC SC Series Storage using Thin Import Abstract The Thin Import feature of Dell Storage Center Operating System offers solutions for data migration

More information

HPE SIM for NonStop Manageability

HPE SIM for NonStop Manageability HPE SIM for NonStop Manageability Part Number: 575075-005R Published: January 2016 Edition: J06.03 and subsequent J-series RVUs, H06.03 and subsequent H-series RVUs, and G06.15 and subsequent G-series

More information

ISILON ETHERNET BACKEND NETWORK OVERVIEW

ISILON ETHERNET BACKEND NETWORK OVERVIEW WHITE PAPER ISILON ETHERNET BACKEND NETWORK OVERVIEW Abstract This white paper provides an introduction to the Ethernet backend network for Dell EMC Isilon scale-out NAS. August 2017 Isilon 1 Isilon Ethernet

More information

Using the Certificate Authority Proxy Function

Using the Certificate Authority Proxy Function CHAPTER 10 This chapter provides information on the following topics: Certificate Authority Proxy Function Overview, page 10-1 Cisco Unified IP Phone and CAPF Interaction, page 10-2 CAPF Interaction with

More information

IBM. PDF file of IBM Knowledge Center topics. IBM Operations Analytics for z Systems. Version 2 Release 2

IBM. PDF file of IBM Knowledge Center topics. IBM Operations Analytics for z Systems. Version 2 Release 2 IBM Operations Analytics for z Systems IBM PDF file of IBM Knowledge Center topics Version 2 Release 2 IBM Operations Analytics for z Systems IBM PDF file of IBM Knowledge Center topics Version 2 Release

More information

HPE NonStop Development Environment for Eclipse 6.0 Debugging Supplement

HPE NonStop Development Environment for Eclipse 6.0 Debugging Supplement HPE NonStop Development Environment for Eclipse 6.0 Debugging Supplement Part Number: 831776-001 Published: June 2016 Edition: L16.05 and subsequent L-series RVUs, J06.20 and subsequent J-series RVUs Copyright

More information

OceanStor 9000 InfiniBand Technical White Paper. Issue V1.01 Date HUAWEI TECHNOLOGIES CO., LTD.

OceanStor 9000 InfiniBand Technical White Paper. Issue V1.01 Date HUAWEI TECHNOLOGIES CO., LTD. OceanStor 9000 Issue V1.01 Date 2014-03-29 HUAWEI TECHNOLOGIES CO., LTD. Copyright Huawei Technologies Co., Ltd. 2014. All rights reserved. No part of this document may be reproduced or transmitted in

More information

OSM Service Connection User's Guide

OSM Service Connection User's Guide OSM Service Connection User's Guide Part Number: 879519-001 Published: March 017 Edition: J06.03 and subsequent J-series RVUs and H06.03 and subsequent H-series RVUs. Copyright 016, 017 Hewlett Packard

More information

InfiniBand and Mellanox UFM Fundamentals

InfiniBand and Mellanox UFM Fundamentals InfiniBand and Mellanox UFM Fundamentals Part Number: MTR-IB-UFM-OST-A Duration: 3 Days What's in it for me? Where do I start learning about InfiniBand? How can I gain the tools to manage this fabric?

More information

vcenter Server Appliance Configuration Update 1 Modified on 04 OCT 2017 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

vcenter Server Appliance Configuration Update 1 Modified on 04 OCT 2017 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 Update 1 Modified on 04 OCT 2017 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 You can find the most up-to-date technical documentation on the VMware Web site at: https://docs.vmware.com/ The VMware

More information

HP Virtual Connect for c-class BladeSystem Setup and Installation Guide

HP Virtual Connect for c-class BladeSystem Setup and Installation Guide HP Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.01 Abstract This document contains setup, installation, and configuration information for HP Virtual Connect. This document

More information

HPE IMC DBA User Database to IMC User Database Restoration Configuration Examples

HPE IMC DBA User Database to IMC User Database Restoration Configuration Examples HPE IMC DBA User Database to IMC User Database Restoration Configuration Examples Part number: 5200-1335 Software version: IMC PLAT 7.2 (E0403) The information in this document is subject to change without

More information

Cisco SFS 7008 InfiniBand Server Switch (96-port)

Cisco SFS 7008 InfiniBand Server Switch (96-port) Q&A Cisco SFS 7000 Series Infiniband Server Switches Q. What are the Cisco SFS 7000 Series InfiniBand switches? A. The Cisco SFS 7000 Series InfiniBand switches are a new series of high-performance InfiniBand

More information

Install ISE on a VMware Virtual Machine

Install ISE on a VMware Virtual Machine Supported VMware Versions, page 1 Support for VMware vmotion, page 1 Support for Open Virtualization Format, page 2 Virtual Machine Requirements, page 2 Virtual Machine Resource and Performance Checks,

More information

HPE ilo Federation User Guide for ilo 5

HPE ilo Federation User Guide for ilo 5 HPE ilo Federation User Guide for ilo 5 Abstract This guide explains how to configure and use the HPE ilo Federation features. It is intended for system administrators, Hewlett Packard Enterprise representatives,

More information

Add and Remove Nodes

Add and Remove Nodes 14 CHAPTER The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration.

More information

Pass-Through Technology

Pass-Through Technology CHAPTER 3 This chapter provides best design practices for deploying blade servers using pass-through technology within the Cisco Data Center Networking Architecture, describes blade server architecture,

More information

HPE Integrity NonStop i BladeSystem Planning Guide

HPE Integrity NonStop i BladeSystem Planning Guide HPE Integrity NonStop i BladeSystem Planning Guide Part Number: 545740-024 Published: May 207 Edition: J06.3 and subsequent J-series RVUs Copyright 203, 207 Hewlett Packard Enterprise Development LP The

More information

Overview. Cisco UCS Manager User Documentation

Overview. Cisco UCS Manager User Documentation Cisco UCS Manager User Documentation, page 1 Infrastructure Management Guide, page 2 Cisco Unified Computing System, page 3 Cisco UCS Building Blocks and Connectivity, page 5 Cisco UCS Manager User Documentation

More information

Designing SAN Using Cisco MDS 9000 Series Fabric Switches

Designing SAN Using Cisco MDS 9000 Series Fabric Switches White Paper Designing SAN Using Cisco MDS 9000 Series Fabric Switches September 2016 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 1 of 15 Contents What You

More information

Module 2 Storage Network Architecture

Module 2 Storage Network Architecture Module 2 Storage Network Architecture 1. SCSI 2. FC Protocol Stack 3. SAN:FC SAN 4. IP Storage 5. Infiniband and Virtual Interfaces FIBRE CHANNEL SAN 1. First consider the three FC topologies pointto-point,

More information

Add and Remove Nodes

Add and Remove Nodes CHAPTER 12 The terms Unidirectional Path Switched Ring and UPSR may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration.

More information

SAP BusinessObjects Profitability and Cost Management Upgrade Guide

SAP BusinessObjects Profitability and Cost Management Upgrade Guide PUBLIC SAP BusinessObjects Profitability and Cost Management Document Version: 10.0 2019-04-09 SAP BusinessObjects Profitability and Cost Management Upgrade Guide 2019 SAP SE or an SAP affiliate company.

More information

vrealize Operations Management Pack for NSX for Multi-Hypervisor

vrealize Operations Management Pack for NSX for Multi-Hypervisor vrealize Operations Management Pack for This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more

More information

HP Data Protector Integration with Autonomy IDOL Server

HP Data Protector Integration with Autonomy IDOL Server Technical white paper HP Data Protector Integration with Autonomy IDOL Server Introducing e-discovery for HP Data Protector environments Table of contents Summary 2 Introduction 2 Integration concepts

More information

vrealize Operations Management Pack for NSX for vsphere 2.0

vrealize Operations Management Pack for NSX for vsphere 2.0 vrealize Operations Management Pack for NSX for vsphere 2.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition.

More information

VMware vrealize Operations for Horizon Administration

VMware vrealize Operations for Horizon Administration VMware vrealize Operations for Horizon Administration vrealize Operations for Horizon 6.3 This document supports the version of each product listed and supports all subsequent versions until the document

More information

Extend your DB2 purescale cluster to another city- Geographically Dispersed purescale Cluster

Extend your DB2 purescale cluster to another city- Geographically Dispersed purescale Cluster Extend your DB2 purescale cluster to another city- Geographically Dispersed purescale Cluster Roy Cecil IBM Session Code: 5 16 April 2014, 16:00 Platform: LUW 2 Agenda Introduction Disaster Recovery &

More information

HPE ConvergedSystem 700 for Hyper-V Deployment Accelerator Service

HPE ConvergedSystem 700 for Hyper-V Deployment Accelerator Service Data sheet HPE ConvergedSystem 700 for Hyper-V Deployment Accelerator Service HPE Technology Consulting HPE ConvergedSystem 700 for Hyper-V is a solution that allows you to acquire and deploy a virtualization

More information

Unable to Connect to the Master Service Processors (MSPs) Over a Low-Level Link

Unable to Connect to the Master Service Processors (MSPs) Over a Low-Level Link Unable to Connect to the Master Service Processors (MSPs) Over a Low-Level Link Symptom Version Problem Fix Unable to connect to a master service processor (MSP) using either the OSM or TSM Low-Level Link,

More information

Upgrading Firmware through Auto Install

Upgrading Firmware through Auto Install This chapter includes the following sections: Firmware Upgrades through Auto Install, page 1 Required Order of Steps for Auto Install, page 3 Upgrading the Infrastructure Firmware with Auto Install, page

More information

Install ISE on a VMware Virtual Machine

Install ISE on a VMware Virtual Machine Supported VMware Versions, page 1 Support for VMware vmotion, page 1 Support for Open Virtualization Format, page 2 Virtual Machine Requirements, page 3 Virtual Machine Resource and Performance Checks,

More information

HP P6000 Cluster Extension Software Installation Guide

HP P6000 Cluster Extension Software Installation Guide HP P6000 Cluster Extension Software Installation Guide This guide contains detailed instructions for installing and removing HP P6000 Cluster Extension Software in Windows and Linux environments. The intended

More information

Turn Up a Node. Before You Begin CHAPTER

Turn Up a Node. Before You Begin CHAPTER CHAPTER 4 Turn Up a Node This chapter explains how to provision a single Cisco ONS 15600 node and turn it up for service, including node name, date and time, timing references, network attributes such

More information

Dell FluidFS Version 6.0 FS8600 Appliance Deployment Guide

Dell FluidFS Version 6.0 FS8600 Appliance Deployment Guide Dell FluidFS Version 6.0 FS8600 Appliance Deployment Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION

More information

VMware Mirage Getting Started Guide

VMware Mirage Getting Started Guide Mirage 5.8 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions of this document,

More information

LAN Ports and Port Channels

LAN Ports and Port Channels Port Modes, page 2 Port Types, page 2 UCS 6300 Breakout 40 GB Ethernet Ports, page 3 Unified Ports, page 7 Changing Port Modes, page 10 Server Ports, page 16 Uplink Ethernet Ports, page 17 Appliance Ports,

More information

UCS Uplink Ethernet Connection Configuration Example

UCS Uplink Ethernet Connection Configuration Example UCS Uplink Ethernet Connection Configuration Example Document ID: 110267 Contents Introduction Prerequisites Requirements Components Used Conventions Configure Network Diagram 1. Configure Uplink Ethernet

More information

vcenter Server Appliance Configuration Modified on 17 APR 2018 VMware vsphere 6.7 VMware ESXi 6.7 vcenter Server 6.7

vcenter Server Appliance Configuration Modified on 17 APR 2018 VMware vsphere 6.7 VMware ESXi 6.7 vcenter Server 6.7 vcenter Server Appliance Configuration Modified on 17 APR 2018 VMware vsphere 6.7 VMware ESXi 6.7 vcenter Server 6.7 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/

More information

Amazon Relational Database Service. Getting Started Guide API Version

Amazon Relational Database Service. Getting Started Guide API Version Amazon Relational Database Service Getting Started Amazon Relational Database Service: Getting Started Copyright 2010 Amazon Web Services LLC or its affiliates. All rights reserved. Table of Contents Get

More information

M8801A / M8802A ACL Tape Library Installation and User s Guide

M8801A / M8802A ACL Tape Library Installation and User s Guide M8801A / M8802A ACL Tape Library Installation and User s Guide Abstract This guide provides information about installing, operating, and maintaining the M8801A and M8802A on HP NonStop Integrity NS-series

More information

Install ISE on a VMware Virtual Machine

Install ISE on a VMware Virtual Machine ISE Features Not Supported in a Virtual Machine, page 1 Supported VMware Versions, page 1 Support for VMware vmotion, page 2 Support for Open Virtualization Format, page 2 Virtual Machine Requirements,

More information

Messaging Overview. Introduction. Gen-Z Messaging

Messaging Overview. Introduction. Gen-Z Messaging Page 1 of 6 Messaging Overview Introduction Gen-Z is a new data access technology that not only enhances memory and data storage solutions, but also provides a framework for both optimized and traditional

More information

Nighthawk S8000 Gaming & Streaming Advanced 8-Port Gigabit Ethernet Switch User Manual

Nighthawk S8000 Gaming & Streaming Advanced 8-Port Gigabit Ethernet Switch User Manual Nighthawk S8000 Gaming & Streaming Advanced 8-Port Gigabit Ethernet Switch User Manual Model GS808E March 2017 202-11732-01 350 E. Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing

More information

ProSAFE 8-Port and 16-Port 10-Gigabit Ethernet Web Managed Switch Models XS708Ev2 and XS716E User Manual

ProSAFE 8-Port and 16-Port 10-Gigabit Ethernet Web Managed Switch Models XS708Ev2 and XS716E User Manual ProSAFE 8-Port and 16-Port 10-Gigabit Ethernet Web Managed Switch Models XS708Ev2 and XS716E User Manual March 2017 202-11656-03 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing

More information

ISILON ETHERNET BACKEND NETWORK OVERVIEW

ISILON ETHERNET BACKEND NETWORK OVERVIEW WHITE PAPER ISILON ETHERNET BACKEND NETWORK OVERVIEW Abstract This white paper provides an introduction to the Ethernet backend network for Dell EMC Isilon scale-out NAS. November 2018 Isilon 1 Isilon

More information

HPE StoreVirtual OS v13.5 Release Notes

HPE StoreVirtual OS v13.5 Release Notes HPE StoreVirtual OS v13.5 Release Notes Part Number: 865552-006 Published: May 2017 Edition: 2 Contents Release notes...4 Description... 4 Platforms supported for this release... 4 Update recommendation...4

More information

HP Converged Network Switches and Adapters. HP StorageWorks 2408 Converged Network Switch

HP Converged Network Switches and Adapters. HP StorageWorks 2408 Converged Network Switch HP Converged Network Switches and Adapters Family Data sheet Realise the advantages of Converged Infrastructure with HP Converged Network Switches and Adapters Data centres are increasingly being filled

More information

VMware vrealize Operations for Horizon Installation

VMware vrealize Operations for Horizon Installation VMware vrealize Operations for Horizon Installation vrealize Operations for Horizon 6.4 Installation vrealize Operations for Horizon 6.4 This document supports the version of each product listed and supports

More information

BITUG 2013 NonStop Big Sig HP NonStop update

BITUG 2013 NonStop Big Sig HP NonStop update BITUG 2013 NonStop Big Sig HP NonStop update Mark Pollans Sr. Worldwide Product Manager, HP December 2013 Forward-looking statements This is a rolling (up to three year) roadmap and is subject to change

More information

Add and Remove Nodes

Add and Remove Nodes CHAPTER 14 Add and Remove Nodes This chapter explains how to add and remove Cisco ONS 15454 SDH nodes from multiplex section-shared protection rings (MS-SPRings), subnetwork connection protection (SNCP)

More information

EASYHA SQL SERVER V1.0

EASYHA SQL SERVER V1.0 EASYHA SQL SERVER V1.0 CONTENTS 1 Introduction... 2 2 Install SQL 2016 in Azure... 3 3 Windows Failover Cluster Feature Installation... 7 4 Windows Failover Clustering Configuration... 9 4.1 Configure

More information

Installation. Installation Overview. Installation and Configuration Taskflows CHAPTER

Installation. Installation Overview. Installation and Configuration Taskflows CHAPTER CHAPTER 4 Overview, page 4-1 Navigate the Wizard, page 4-7 Install and Configure Cisco Unified Presence, page 4-7 Perform a Fresh Multi-Node, page 4-15 Overview Cisco Unified Presence supports the following

More information

Technical Brief: Titan & Alacritech iscsi Accelerator on Microsoft Windows

Technical Brief: Titan & Alacritech iscsi Accelerator on Microsoft Windows Technical Brief: Titan & Alacritech iscsi Accelerator on Microsoft Windows Abstract In today s information age, enterprise business processing & information systems are growing at an incredibly fast pace

More information

IBM TotalStorage SAN Switch F08

IBM TotalStorage SAN Switch F08 Entry workgroup fabric connectivity, scalable with core/edge fabrics to large enterprise SANs IBM TotalStorage SAN Switch F08 Entry fabric switch with high performance and advanced fabric services Highlights

More information

CA Spectrum. Remote Operations Suite User Guide. Release 9.3

CA Spectrum. Remote Operations Suite User Guide. Release 9.3 CA Spectrum Remote Operations Suite User Guide Release 9.3 This Documentation, which includes embedded help systems and electronically distributed materials, (hereinafter referred to as the Documentation

More information

3.1. Storage. Direct Attached Storage (DAS)

3.1. Storage. Direct Attached Storage (DAS) 3.1. Storage Data storage and access is a primary function of a network and selection of the right storage strategy is critical. The following table describes the options for server and network storage.

More information

Troubleshooting Cisco APIC-EM Single and Multi-Host

Troubleshooting Cisco APIC-EM Single and Multi-Host Troubleshooting Cisco APIC-EM Single and Multi-Host The following information may be used to troubleshoot Cisco APIC-EM single and multi-host: Recovery Procedures for Cisco APIC-EM Node Failures, page

More information

QuickSpecs. StorageWorks Fibre Channel SAN Switch 16-EL by Compaq M ODELS O VERVIEW

QuickSpecs. StorageWorks Fibre Channel SAN Switch 16-EL by Compaq M ODELS O VERVIEW M ODELS Fibre Channel Switch 16-EL 212776-B21 253740-001 Fibre Channel Switch 16-EL - Bundle What is New This model is the only Compaq Switch that comes with a set of rack mounting rails, allowing the

More information

Add and Remove Nodes

Add and Remove Nodes 13 CHAPTER The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration.

More information

Common Issues With Two Fiber Bidirectional Line Switched Rings

Common Issues With Two Fiber Bidirectional Line Switched Rings Common Issues With Two Fiber Bidirectional Line Switched Rings Document ID: 13556 Contents Introduction Prerequisites Requirements Components Used Conventions Background Information Working and Protect

More information

Data collected by Trend Micro is subject to the conditions stated in the Trend Micro Privacy Policy:

Data collected by Trend Micro is subject to the conditions stated in the Trend Micro Privacy Policy: Privacy and Personal Data Collection Disclosure Certain features available in Trend Micro products collect and send feedback regarding product usage and detection information to Trend Micro. Some of this

More information

DEPLOYMENT GUIDE DEPLOYING F5 WITH ORACLE ACCESS MANAGER

DEPLOYMENT GUIDE DEPLOYING F5 WITH ORACLE ACCESS MANAGER DEPLOYMENT GUIDE DEPLOYING F5 WITH ORACLE ACCESS MANAGER Table of Contents Table of Contents Introducing the F5 and Oracle Access Manager configuration Prerequisites and configuration notes... 1 Configuration

More information

IBM PureFlex System: New features available

IBM PureFlex System: New features available IBM United States Hardware Announcement 112-182, dated November 13, 2012 IBM PureFlex System: New features available Table of contents 1 Overview 7 Publications 2 Key prerequisites 7 Technical information

More information

Installation Guide Release for Microsoft Windows

Installation Guide Release for Microsoft Windows [1]Oracle Fail Safe Installation Guide Release 4.1.1 for Microsoft Windows E57046-01 January 2015 Oracle Fail Safe Installation Guide, Release 4.1.1 for Microsoft Windows E57046-01 Copyright 1999, 2015,

More information

EMC Secure Remote Support Device Client for Symmetrix Release 2.00

EMC Secure Remote Support Device Client for Symmetrix Release 2.00 EMC Secure Remote Support Device Client for Symmetrix Release 2.00 Support Document P/N 300-012-112 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright

More information

HP EVA Cluster Extension Software Installation Guide

HP EVA Cluster Extension Software Installation Guide HP EVA Cluster Extension Software Installation Guide Abstract This guide contains detailed instructions for installing and removing HP EVA Cluster Extension Software in Windows and Linux environments.

More information

Migration. 22 AUG 2017 VMware Validated Design 4.1 VMware Validated Design for Software-Defined Data Center 4.1

Migration. 22 AUG 2017 VMware Validated Design 4.1 VMware Validated Design for Software-Defined Data Center 4.1 22 AUG 2017 VMware Validated Design 4.1 VMware Validated Design for Software-Defined Data Center 4.1 You can find the most up-to-date technical documentation on the VMware Web site at: https://docs.vmware.com/

More information

VMware Identity Manager Connector Installation and Configuration (Legacy Mode)

VMware Identity Manager Connector Installation and Configuration (Legacy Mode) VMware Identity Manager Connector Installation and Configuration (Legacy Mode) VMware Identity Manager This document supports the version of each product listed and supports all subsequent versions until

More information

Cisco TelePresence TelePresence Server MSE 8710

Cisco TelePresence TelePresence Server MSE 8710 Cisco TelePresence TelePresence Server MSE 8710 Installation Guide 61-0025-05 August 2013 Contents General information 3 About the Cisco TelePresence Server MSE 8710 3 Port and LED locations 3 LED behavior

More information

HPE Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.60

HPE Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.60 HPE Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.60 Abstract This document contains setup, installation, and configuration information for HPE Virtual Connect. This document

More information

NonStop Development Environment for Eclipse 4.0 Debugging Supplement

NonStop Development Environment for Eclipse 4.0 Debugging Supplement NonStop Development Environment for Eclipse 4.0 Debugging Supplement HP Part Number: 732675-001 Published: October 2013 Edition: NSDEE 4.0, J06.03 and subsequent J-series RVUs, H06.08 and subsequent H-series

More information

Platform Administration

Platform Administration CHAPTER 6 Cisco provides these tools to manage the Cisco MobilityManager server platform: Cisco IPT web pages that provide complete platform administration functions. Command Line Interface (CLI) that

More information

VMware vrealize Operations for Horizon Installation. VMware vrealize Operations for Horizon 6.5

VMware vrealize Operations for Horizon Installation. VMware vrealize Operations for Horizon 6.5 VMware vrealize Operations for Horizon Installation VMware vrealize Operations for Horizon 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/

More information

Managing Blade Servers

Managing Blade Servers This chapter includes the following sections: Blade Server Management, page 2 Guidelines for Removing and Decommissioning Blade Servers, page 2 Recommendations for Avoiding Unexpected Server Power Changes,

More information

Network-Level High Availability

Network-Level High Availability This chapter describes Cisco NX-OS network high availability and includes the following sections: Information About, page 1 Licensing Requirements, page 2 Spanning Tree Protocol, page 2 Virtual Port Channels,

More information

EventMaster PLUS! Version 4 Installation and Upgrade Guide. Workgroup Deployment Microsoft MSDE 2000

EventMaster PLUS! Version 4 Installation and Upgrade Guide. Workgroup Deployment Microsoft MSDE 2000 EventMaster PLUS! Version 4 Installation and Upgrade Guide Deployment Microsoft MSDE 2000 EventMaster4 PLUS! EventMaster4 PLUS! EventMaster4 PLUS! EventMaster4 PLUS! Please send any comments regarding

More information

Processor Halt Codes Manual

Processor Halt Codes Manual Processor Halt Codes Manual Part Number: 867523-004 Published: April 2018 Edition: L15.02 and J06.03 and all subsequent L-series and J-series RVUs. Copyright 2015, 2018 Hewlett Packard Enterprise Development

More information

HP Database and Middleware Automation

HP Database and Middleware Automation HP Database and Middleware Automation For Windows Software Version: 10.10 SQL Server Database Refresh User Guide Document Release Date: June 2013 Software Release Date: June 2013 Legal Notices Warranty

More information

Silk Performance Manager Installation and Setup Help

Silk Performance Manager Installation and Setup Help Silk Performance Manager 18.5 Installation and Setup Help Micro Focus The Lawn 22-30 Old Bath Road Newbury, Berkshire RG14 1QN UK http://www.microfocus.com Copyright 2004-2017 Micro Focus. All rights reserved.

More information

Cisco TelePresence MCU MSE 8510

Cisco TelePresence MCU MSE 8510 Cisco TelePresence MCU MSE 8510 Installation Guide 61-0021-04 August 2013 Contents General information 3 About the Cisco TelePresence MCU MSE 8510 3 Port and LED locations 3 LED behavior 3 Installing the

More information

Viewing System Status, page 404. Backing Up and Restoring a Configuration, page 416. Managing Certificates for Authentication, page 418

Viewing System Status, page 404. Backing Up and Restoring a Configuration, page 416. Managing Certificates for Authentication, page 418 This chapter describes how to maintain the configuration and firmware, reboot or reset the security appliance, manage the security license and digital certificates, and configure other features to help

More information

IBM TotalStorage SAN Switch F32

IBM TotalStorage SAN Switch F32 Intelligent fabric switch with enterprise performance for midrange and large storage networks IBM TotalStorage SAN Switch F32 High port density packaging helps save rack space Highlights Can be used as

More information

More on LANS. LAN Wiring, Interface

More on LANS. LAN Wiring, Interface More on LANS Chapters 10-11 LAN Wiring, Interface Mostly covered this material already NIC = Network Interface Card Separate processor, buffers incoming/outgoing data CPU might not be able to keep up network

More information

Version 1.4 Paribus Discovery for Microsoft Dynamics CRM User Guide

Version 1.4 Paribus Discovery for Microsoft Dynamics CRM User Guide Version 1.4 Paribus Discovery for Microsoft Dynamics CRM User Guide Document Version 1.3 Release Date: September 2011 QGate Software Limited D2 Fareham Heights, Standard Way, Fareham Hampshire, PO16 8XT

More information

HPE Data Replication Solution Service for HPE Business Copy for P9000 XP Disk Array Family

HPE Data Replication Solution Service for HPE Business Copy for P9000 XP Disk Array Family Data sheet HPE Data Replication Solution Service for HPE Business Copy for P9000 XP Disk Array Family HPE Lifecycle Event Services HPE Data Replication Solution Service provides implementation of the HPE

More information

QLogic InfiniBand Cluster Planning Guide

QLogic InfiniBand Cluster Planning Guide QLogic InfiniBand Guide D000051-001 Preliminary QLogic Guide Information furnished in this manual is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its

More information

Highest Levels of Scalability Simplified Network Manageability Maximum System Productivity

Highest Levels of Scalability Simplified Network Manageability Maximum System Productivity InfiniBand Brochure Highest Levels of Scalability Simplified Network Manageability Maximum System Productivity 40/56/100/200Gb/s InfiniBand Switch System Family MELLANOX SMART INFINIBAND SWITCH SYSTEMS

More information

HPE StoreVirtual Storage Application Aware Snapshot Manager Deployment Guide

HPE StoreVirtual Storage Application Aware Snapshot Manager Deployment Guide HPE StoreVirtual Storage Application Aware Snapshot Manager Deployment Guide Abstract This guide contains instructions for installing and deploying the StoreVirtual Application Aware Snapshot Manager to

More information

Cisco Prime Optical 9.5 Basic External Authentication

Cisco Prime Optical 9.5 Basic External Authentication Cisco Prime Optical 9.5 Basic External Authentication June 6, 2012 This document describes the basic external authentication functionality in Cisco Prime Optical 9.5 running on a Solaris server. External

More information

Mid-Range Library Media Manager Installation and User s Guide

Mid-Range Library Media Manager Installation and User s Guide Mid-Range Library Media Manager Installation and User s Guide Abstract This guide describes how to install and use the Mid-Range Library Media Manager software. It includes information about connection

More information

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information...

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information... Installation Checklist HP ProLiant Cluster F500 for Enterprise Virtual Array 4000/6000/8000 using Microsoft Windows Server 2003, Enterprise Edition Stretch Cluster May 2005 Table of Contents ProLiant Cluster

More information

Mellanox InfiniBand (IB) EDR Switches are supported to work with HPE InfiniBand Adapters to deliver high performance

Mellanox InfiniBand (IB) EDR Switches are supported to work with HPE InfiniBand Adapters to deliver high performance Overview Mellanox InfiniBand EDR Switch Series Mellanox InfiniBand (IB) EDR Switches are supported to work with HPE InfiniBand Adapters to deliver high performance connectivity for HPC clusters using HPE

More information