MicroTech II BACnet Communication Module Ethernet/IP

Size: px
Start display at page:

Download "MicroTech II BACnet Communication Module Ethernet/IP"

Transcription

1 Installation & Maintenance Manual IM703-0 Group: McQuay Controls Date: October 2001 MicroTech II BACnet Communication Module Ethernet/IP ASHRAE 135, Annex J 10 BASE-T 1998 McQuay International

2 Contents Figures...2 Revision History...3 Reference Documents...3 General Information... 4 Description...5 Application...5 Component Data...6 Light Emitting Diodes (LEDs)...6 Headers...6 Installation... 7 Mounting...7 Installing a new MicroTech II BACnet Ethernet/IP Communications Module on the Main Control Board...7 Replacing a MicroTech II BACnet Ethernet/IP Communications Module on the Main Control Board...7 Integration Network Connection...11 BACnet/IP Addressing...11 Configuring the Unit Controller...12 Service Information...13 Test Procedures...13 Replaceable Parts List...13 Installation Kit...13 Figures Figure 1. BACnet Ethernet/IP Communications Module...5 Figure 2. Building Automation System...5 Figure 3. MicroTech II BACnet Ethernet/IP Communications Module Major Components...6 Figure 4. LonMark Communications Module Main Control Board...8 Figure 5. Mount BACnet Ethernet/IP Communications Module...9 Figure 6. BACnet Ethernet/IP Connection Schematic Diagram...9 Figure 7. BACnet Ethernet Network Cable Routing IM703-0

3 Revision History IM703-0 October 2, 2001 Preliminary release Reference Documents Number IM696 OM137 OM138 ED15060 ANSI/ASHRAE Title MicroTech II Applied Rooftop Unit Controller Installation Manual MicroTech II Applied Rooftop Discharge Air Controller Operation Manual MicroTech II Applied Rooftop Space Comfort Controller Operation Manual MicroTech II Protocol Information Data Applied Rooftop BACnet A Data Communication Protocol for Building Automation and Control Networks Notice Copyright 2001 McQuay International, Minneapolis MN All rights reserved throughout the world. McQuay International reserves the right to change any information contained herein without prior notice. No guarantees are given as to the accuracy of information provided. McQuay and MicroTech are registered trademarks of McQuay International. All other trademarks are the property of their respective owners. IM

4 General Information This manual contains the information you need to install this communications module, incorporate it into the network, and maintain it.! WARNING Electric shock hazard. Can cause personal injury or equipment damage. This equipment must be properly grounded. Connections and service to the MicroTech II control panel must be performed only by personnel that are knowledgeable in the operation of the equipment being controlled.! CAUTION Static sensitive components. Can cause equipment damage. Discharge any static electrical charge by touching the bare metal inside the control panel before performing any service work. Never unplug cables, circuit board terminal blocks, or power plugs while power is applied to the panel. NOTICE This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense. McQuay International disclaims any liability resulting from any interference or for the correction thereof. 4 IM703-0

5 2.60 in Description A MicroTech II BACnet Ethernet/IP Communications Module incorporates a MicroTech II unit controller into an Ethernet Local Area Network (LAN). It is the interface to the network to Building Automation Network using BACnet objects. The MicroTech II BACnet Ethernet/IP Communications Module is a printed circuit board that plugs onto the MicroTech II Main Control Board. Figure 1 shows an outline drawing of the BACnet Ethernet/IP Communications Module. Figure 1. BACnet Ethernet/IP Communications Module 4.00 in Application The MicroTech II BACnet Ethernet/IP Communications Module connects the MicroTech II unit controller to the building automation system (BAS) on a Ethernet Local Area Network. It is the interface adapter for the exchange of BACnet objects between the network and the unit controller. Figure 2 shows the communications module and unit controller integrated into a BAS. Figure 2. Building Automation System MicroTech II Main Control Board MicroTech II BACnet Ethernet I/P Communications Module Ethernet 10BASE-T Network MicroTech II Keypad IM

6 Component Data Figure 3 shows the major components of the communications module. Figure 3. MicroTech II BACnet Ethernet/IP Communications Module Major Components Light Emitting Diodes (LEDs) The MicroTech II BACnet Ethernet/IP Communications Module has three LEDs to indicate communication activity and status of the communication module. LED Function RX Lights when the communications module is receiving data TX Lights when the communications module is transmitting data COL Lights when there is a collision on the Ethernet network Headers The two headers on the component side of the communications module connect the unit controller to the BACnet Ethernet/IP Communications Module through two sets of connector pins on the main control board. 6 IM703-0

7 Installation Mounting The MicroTech II BACnet Ethernet/IP Communications Module can be installed in the field or it can be installed in the factory. The module mounts on connector pins and is held in place with four plastic locking standoffs. The Ethernet network cable connects to an RJ45 jack on the main control board. Installing a new MicroTech II BACnet Ethernet/IP Communications Module on the Main Control Board You can add a new MicroTech II BACnet Ethernet/IP Communications Module to the system in order to incorporate it into an existing Ethernet network. The MicroTech II BACnet Ethernet/IP Communications Module is included in a kit (Part number ) along with a cable harness and this manual. To install a new MicroTech II BACnet Ethernet/IP Communications Module on the MicroTech II Main Control Board 1. Remove power from the Main Control Board. 2. Locate the two empty connectors and four standoffs for the MicroTech II BACnet Ethernet/IP Communications Module on the Main Control Board. See Figure Orient the communications module so that the circuit side faces out (i.e., the component side faces down). Align the communications module so that the connector pins on the Main Control Board can penetrate the headers on the component side of the communications module. See Figure Push the MicroTech II BACnet Ethernet/IP Communications Module onto the connector pins and standoffs until you hear the faint click of the locking standoffs securing the module in place. 5. Connect the communications module to the network. See Figure 6. a. Route the network cable through an opening in the bottom of the cabinet, up the cable raceway, across the shelf below the Main Control Board, and up to the Main Control Board. See Figure 7. b. Plug the network cable into the RJ45 jack on the Main Control Board. 6. Apply power to the Main Control Board. Replacing a MicroTech II BACnet Ethernet/IP Communications Module on the Main Control Board You can replace a MicroTech II BACnet Ethernet/IP Communications Module on the Main Control Board. To replace a MicroTech II BACnet Ethernet/IP Communications Module on the MicroTech II Main Control Board 1. Remove power from the Main Control Board. 2. Locate the four standoffs for the communications module on the Main Control Board. See Figure Use a pliers or screwdriver to depress the barb on one standoff and gently pull the corner of the communications module over the barb. Be careful to not bend the communications module or misalign the connector pins. 4. Proceed to the other three corners, remove the communications module from each standoff, and pull the module over the standoffs. 5. Gently lift the communications module from the Main Control Board. IM

8 6. Orient the replacement communications module so that the circuit side faces out (i.e., the component side faces down). Align the communications module so that the connector pins on the Main Control Board can penetrate the headers on the component side of the communications module. See Figure Push the communications module onto the connector pins and standoffs until you hear the faint click of the locking standoffs securing the module in place. 8. Connect the communications module to the network. See Figure 6. c. Ensure that the network cable is plugged into the RJ45 jack on the Main Control Board. 9. Apply power to the Main Control Board. Figure 4. LonMark Communications Module Main Control Board Location for LonWorks and MSTP BACnet Communications Modules LEDs Locking Standoff (4 places) RJ45 Jack BACnet Ethernet Network Connector 8 IM703-0

9 Figure 5. Mount BACnet Ethernet/IP Communications Module Figure 6. BACnet Ethernet/IP Connection Schematic Diagram Main Control Board (MCB) BACnet Ethernet Network RJ45 Modular Jack MicroTech II BACnet Ethernet Communications Module IM

10 Figure 7. BACnet Ethernet Network Cable Routing Main Control Board BACnet Ethernet Comunications Module Cable Shelf Network Cable RJ45 Jack BACnet Ethernet Network Connection Cable Raceway Terminal Block TB2 Opening in the floor 10 IM703-0

11 Integration Network Connection BACnet/IP Addressing The BACnet/IP (B/IP) address of the MicroTech II Applied Rooftop Unit Controller in a BACnet/IP network consists of the four-octet IP address followed by the two-octet UDP (User Datagram Protocol) port number. The BACnet/IP address is a six-octet value analogous to a MAC address. The IP address portion of the BACnet/IP address must be unique in the BACnet/IP network segment. The default UDP port number in the MicroTech II Applied Rooftop Unit Controller is (BAC0 in hexadecimal). The device object of the MicroTech II Applied Rooftop Unit Controller contains an IP Subnet Mask (Default subnet mask is ) and a unique IP address. The controller does not support DHCP (Dynamic Host Configuration Protocol) IP addressing. The MicroTech II Applied Rooftop Unit Controller can be incorporated into an Ethernet network dedicated to BACnet devices only or an Ethernet network shared with BACnet devices and other devices. Dedicated BACnet Networks For an Ethernet network dedicated to BACnet devices only, the default IP address and IP Subnet Mask in the MicroTech II Applied Rooftop Unit Controller device object may be used. The default IP Address of the controller is written in the device object and can be determined in one of two ways: 1. Construct the IP Address from the MAC Address of the controller (the MAC address is the 18- digit [six-octet] number on the label affixed to the Main Control Board): IP Address Octet Method Range 1 (Most Significant) 172 (this value is fixed) (this value is fixed) 16 3 Either 64 + Logical AND of the Fifth Octet of the MAC Address and 63 or 64 + (Fifth Octet of the MAC Address) Mod (Least Significant) Sixth Octet of the MAC Address The method you use to find the third octet requires further explanation. Either method gives the same answer for this modulus (64). The first method requires that you convert the Fifth Octet of the MAC Address to a binary number and logically AND it bit-by-corresponding-bit with 63 (3F in hex or in binary) and then convert the result to a decimal value and add it to 64. The second method adds 64 to the Fifth Octet of the MAC Address Modulus 64. The result of the Modulus operation is the remainder only (ignore the quotient) of dividing the fifth octet by 64. For example 20 mod 64 is 20 and 65 mod 64 is 1. For example, for a MicroTech II Applied Rooftop Unit Controller with a MAC Address of , the IP address would be = ; ( AND = =.54); = mod 64 = 54; = 118 IM

12 Note: You can use the scientific version of the Windows calculator on you computer to make either of these calculations. 2. Read IP Address property from the device object using a service tool or another BACnet device. To set the IP Address of other BACnet IP devices (workstations, routers, controllers) in the dedicated BACnet Ethernet network select IP Addresses with the first two octets the same as the IP Address of the controller (the default subnet mask is ), and the third and fourth octets close to the third and fourth octets of the MicroTech II Applied Rooftop Unit Controller IP Address. For example, assign the IP Address of the workstation to for the controller in the previous example. Use the same IP Mask in the workstation as in the controller ( ). Shared BACnet Networks Integrating the MicroTech II Applied Rooftop Unit Controller into a shared Ethernet LAN requires close cooperation with the network administrator of the shared Ethernet network. First, obtain the IP Subnet Mask of the shared network from the network administrator. Then, obtain static IP Addresses for all MicroTech II Applied Rooftop Unit Controllers you are integrating into the shared network. Finally obtain the address of an IP Router to use for sending IP messages to and from the BACnet IP subnets. Once you have these, write them to the IP Address, IP Mask, and IP Router Address properties of the device object in the MicroTech II Applied Rooftop Unit Controller. The default BACnet/IP Network Address in the MicroTech II controller is The Network Address must be unique for each BACnet network segment. All BACnet/IP devices on all Ethernet segments must have the same BACnet/IP Network Address. This is the Network Address property of the device object of the MicroTech II Applied Rooftop Unit Controller. Finally, the Communication Option property of the MicroTech II Applied Rooftop Unit Controller device object must be set to NONE for BACnet IP communications to take place. NONE is the default value for this property. Configuring the Unit Controller The MicroTech II Main Control Board and BACnet Ethernet/IP Communications Module are loaded with software, programmed, and configured at the factory as a unit controller. The unit is ready to operate with the default values of the various parameters set at the factory. Default values may be changed with the unit s keypad or via the network. See the appropriate operation manual for default values and keypad operating instructions and see the appropriate MicroTech II Protocol Information Data for descriptions of the network variables. See Reference Documents for part numbers. 12 IM703-0

13 Service Information Test Procedures Replaceable Parts List If you can control the unit from its keypad, but you are not able to communicate with unit via the network: Check the network wiring Check communications Use the standard TCP/IP suite of protocols to check your connectivity with other devices. For example, type ping <IP address of the MicroTech II BACnet Ethernet/IP Communications Module>. If you get a response from that IP address, you are connected to the BACnet Ethernet/IP Communications Module. Use the Transmit LED to determine whether data is reaching the output connector; use the Receive LED to determine whether any responses are being received. If the MicroTech II BACnet Ethernet/IP Communications Module still does not respond, replace the communications module with a new one. Installation Kit Component Description Part No. Kit, Ethernet Installation Kit for BACnet Ethernet/IP Communications Module IM

14 13600 Industrial Park Boulevard, P.O. Box 1551, Minneapolis, MN USA (612)

MicroTech II BACnet Communication Module Ethernet/IP

MicroTech II BACnet Communication Module Ethernet/IP Installation & Maintenance Manual IM703-1 Group: McQuay Controls Date: November 2001 MicroTech II BACnet Communication Module Ethernet/IP ASHRAE 135, Annex J 10 BASE-T 2001 McQuay International Contents

More information

MicroTech II Applied Rooftop Unit Controller and Self-Contained Unit Controller BACnet Communication Module BACnet/IP

MicroTech II Applied Rooftop Unit Controller and Self-Contained Unit Controller BACnet Communication Module BACnet/IP Installation and Maintenance Manual IM703-2 Group: McQuay Controls Date: February 2002 MicroTech II Applied Rooftop Unit Controller and Self-Contained Unit Controller BACnet Communication Module BACnet/IP

More information

MicroTech II TM Applied Rooftop Unit Controller and Self-Contained Unit Controller BACnet TM Communication Module BACnet/IP

MicroTech II TM Applied Rooftop Unit Controller and Self-Contained Unit Controller BACnet TM Communication Module BACnet/IP Installation and Maintenance Manual IM 703-3 Group: Controls Part Number: IM 703-3 Date: November 2004 Supersedes: IM 703-2 MicroTech II TM Applied Rooftop Unit Controller and Self-Contained Unit Controller

More information

MicroTech II Applied Rooftop Unit Controller and Self-Contained Unit Controller BACnet Communication Module MS/TP

MicroTech II Applied Rooftop Unit Controller and Self-Contained Unit Controller BACnet Communication Module MS/TP Installation and Maintenance Manual IM 704-4 Group: Controls Part Number: IM 704 Date: August 2007 Supersedes: IM 704-3 MicroTech II Applied Rooftop Unit Controller and Self-Contained Unit Controller BACnet

More information

MicroTech II Applied TM Rooftop Unit Controller and Self-Contained Unit Controller BACnet TM MSTP Communication Module

MicroTech II Applied TM Rooftop Unit Controller and Self-Contained Unit Controller BACnet TM MSTP Communication Module Installation and Maintenance Manual IM 704-3 Group: Controls Part Number: IM 704-3 Date: November 2004 Supersedes: IM 704-2 MicroTech II Applied TM Rooftop Unit Controller and Self-Contained Unit Controller

More information

MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module

MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module Installation and Maintenance Manual IM 928- Group: Controls Part Number: 66920770 Date: July 2009 Supersedes: IM 928 MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module NOTICE Use this

More information

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module, Ethernet or IP

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module, Ethernet or IP Installation and Maintenance Manual IM 853 Group: Controls Part Number: IM 853 Date: June 2007 Supercedes: New MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module, Ethernet

More information

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module Installation and Maintenance Manual IM 928-2 Group: Controls Part Number: 669207702 Date: March 2011 Supersedes: IM 928-1 MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module NOTICE

More information

MicroTech III Rooftop and Self Contained Unit Controller BACnet IP Communication Module

MicroTech III Rooftop and Self Contained Unit Controller BACnet IP Communication Module Installation and Maintenance Manual IM 916-2 Group: Controls Part Number: IM 916 Date: October 2009 Supercedes: IM 916-1 MicroTech III Rooftop and Self Contained Unit Controller BACnet IP Communication

More information

MicroTech III Chiller Unit Controller BACnet IP Communication Module

MicroTech III Chiller Unit Controller BACnet IP Communication Module Installation and Maintenance Manual IM 966 Group: Controls Part Number: IM 966 Date: October 2009 Supercedes: New MicroTech III Chiller Unit Controller BACnet IP Communication Module Pathfinder Chiller,

More information

Magnitude TM Chiller Unit Controller BACnet Communication Module (MS/TP, IP, Ethernet)

Magnitude TM Chiller Unit Controller BACnet Communication Module (MS/TP, IP, Ethernet) Installation and Maintenance Manual IM 963 Group: Controls Part Number: IM 963 Date: April 2010 Supercedes: New Magnitude TM Chiller Unit Controller BACnet Communication Module (MS/TP, IP, Ethernet) Daikin

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BACnet Communication Card RXRX-AY01 RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION! WARNING THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED

More information

MicroTech III McQuay Chiller Unit Controller BACnet Communication Module (MS/TP)

MicroTech III McQuay Chiller Unit Controller BACnet Communication Module (MS/TP) Installation and Maintenance Manual IM 967 Group: Controls Part Number: IM 967 Date: October 2009 Supercedes: New MicroTech III McQuay Chiller Unit Controller BACnet Communication Module (MS/TP) Pathfinder

More information

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP) Installation and Maintenance Manual IM 852-2 Group: Controls Part Number: IM 852 Date: January 2008 Supercedes: IM 852-1 MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module

More information

BCM. MicroTech II Chiller Unit Controller BACnet Communication Module. Installation and Maintenance Manual IM ASHRAE 135, MCQ Rev.

BCM. MicroTech II Chiller Unit Controller BACnet Communication Module. Installation and Maintenance Manual IM ASHRAE 135, MCQ Rev. Installation and Maintenance Manual IM 736-0 Part No: 736015423 Group: McQuay Controls Date: January 2003 MicroTech II Chiller Unit Controller BACnet Communication Module ASHRAE 135, 2001 WSC Water-Cooled

More information

Installation and Maintenance Manual IM 966-3

Installation and Maintenance Manual IM 966-3 Installation and Maintenance Manual IM 966-3 Group: Controls Part Number: IM 966 Date: March 2017 MicroTech III Chiller BACnet IP Communication Module Models AGZ and AMZ Trailblazer Air-Cooled Scroll Chiller

More information

MicroTech II Alerton BACtalk Integration Information for MicroTech II Applied Rooftop and Self-Contained Unit Controllers

MicroTech II Alerton BACtalk Integration Information for MicroTech II Applied Rooftop and Self-Contained Unit Controllers Engineering Data ED15080-1 Group: Controls Date: June 2002 MicroTech II Alerton BACtalk Integration Information for MicroTech II Applied Rooftop and Self-Contained Unit Controllers Alerton BACtalk Building

More information

LONWORKS Plug-In Software

LONWORKS Plug-In Software Installation and Maintenance Manual IM 933 Group: McQuay Controls Part Number: IM 933 Date: September 2008 Supercedes: New LONWORKS Plug-In Software For use with the MicroTech III Unitary Controller -

More information

Installation and Maintenance Manual IM 966-4

Installation and Maintenance Manual IM 966-4 Installation and Maintenance Manual IM 966-4 Group: Controls Part Number: IM 966 Date: January 2018 MicroTech III Chiller Unit Controller BACnet IP Communication Module Models AGZ and AMZ Trailblazer Air-cooled

More information

MicroTech II Alerton BACtalk Integration Information for MicroTech II Applied Rooftop and Self-Contained Unit Controllers

MicroTech II Alerton BACtalk Integration Information for MicroTech II Applied Rooftop and Self-Contained Unit Controllers Engineering Data ED 15080-2 Group: Controls Part Number: ED 15080 Date: April 2006 Supercedes: ED 15080-1 MicroTech II Alerton BACtalk Integration Information for MicroTech II Applied Rooftop and Self-Contained

More information

MicroTech II Chiller Unit Controller BACnet Communication Module

MicroTech II Chiller Unit Controller BACnet Communication Module Installation and Maintenance Manual IM 736-2 Group: Controls Part Number: IM 736 Date: November 2005 Supercedes: IM 736-1 MicroTech II Chiller Unit Controller BACnet Communication Module WSC WDC WPV HSC

More information

MicroTech Modem Kit. Installation & Maintenance Data IM 682. Group: Controls Part Number: Date: October, 1996.

MicroTech Modem Kit. Installation & Maintenance Data IM 682. Group: Controls Part Number: Date: October, 1996. Installation & Maintenance Data IM 682 Group: Controls Part Number: 629976 Date: October, 1996 MicroTech Modem Kit Telephone Line Modem Controller cns no. a0006 1996 McQuay International Contents Contents...2

More information

Installation and Maintenance Manual IM 963-2

Installation and Maintenance Manual IM 963-2 Installation and Maintenance Manual IM 963-2 Group: Controls Part Number: IM 963 Date: March 2017 Daikin Magnitude Chiller BACnet Networks (MS/TP, IP, Ethernet) Communication Module Model WME Magnetic

More information

Installation and Maintenance Manual IM 928-5

Installation and Maintenance Manual IM 928-5 Installation and Maintenance Manual IM 928-5 MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module Group: Controls Part Number: IM 928 Date: February 2016 Table of Contents Introduction....

More information

Installation and Maintenance Manual IM

Installation and Maintenance Manual IM Installation and Maintenance Manual IM 1013-1 MicroTech III Fan Coil BACnet MS/TP Communication Module Group: Controls Part Number: IM 1013 Date: February 2016 Table of Contents Introduction.... 3 Revision

More information

MicroTech II Chiller Unit Controller LonWorks Communication Module

MicroTech II Chiller Unit Controller LonWorks Communication Module Installation and Maintenance IM 735-1 Group: Controls Part Number: IM 735 Date: May 2005 Supersedes: IM735-0 MicroTech II Chiller Unit Controller LonWorks Communication Module WSC Water-Cooled Centrifugal,

More information

Installation and Maintenance Manual IM Replacement Intelligent Equipment Gateway

Installation and Maintenance Manual IM Replacement Intelligent Equipment Gateway Installation and Maintenance Manual IM 1229 Group: Controls Replacement Intelligent Equipment Gateway Commercial Rooftop Models: DPS and MPS Applied Rooftop Models: RDS and RPS Part Number: 910159718 Date:

More information

MicroTech II Chiller Unit Controller BACnet Communication Module, Ethernet or IP

MicroTech II Chiller Unit Controller BACnet Communication Module, Ethernet or IP Installation and Maintenance Manual IM 837 Group: Controls Part Number: IM 837 Date: June 2006 Supercedes: New MicroTech II Chiller Unit Controller BACnet Communication Module, Ethernet or IP WSC Water-Cooled

More information

Installation and Maintenance Manual IM

Installation and Maintenance Manual IM Installation and Maintenance Manual IM 1229-1 Group: Controls Replacement Intelligent Equipment Gateway Commercial Rooftop Models: DPS and MPS Applied Rooftop Models: RDS and RPS Part Number: 910159718

More information

BACnet VAV Actuator Start-up Guide IM 1040

BACnet VAV Actuator Start-up Guide IM 1040 BACnet VAV Actuator Start-up Guide IM 1040 Group: Controls Part Number: IM 1040 Date: 3/4/2010 Supersedes: New BACnet VAV Actuator--Electronic Output Start-up Procedures 2010 McQuay International Table

More information

Installation and Maintenance Manual IM 969-5

Installation and Maintenance Manual IM 969-5 Installation and Maintenance Manual IM 969-5 Group: Controls Part Number: IM 969 Date: January 2018 MicroTech III Chiller Unit Controller Modbus Communication Module Models AGZ and AMZ Trailblazer Air-cooled

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS LonWorks Communication Card RXRX-AY02 RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION! WARNING THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED

More information

MicroTech II McQuay Chiller Unit Controller BACnet Communication Module (MS/TP)

MicroTech II McQuay Chiller Unit Controller BACnet Communication Module (MS/TP) Installation and Maintenance Manual IM 906 Group: Controls Part Number: IM 906 Date: February 2008 Supersedes: New MicroTech II McQuay Chiller Unit Controller BACnet Communication Module (MS/TP) WSC WDC

More information

Installation and Operation Manual IM

Installation and Operation Manual IM Installation and Operation Manual IM 1005-4 MicroTech III Unit Controller Remote User Interface Group: Controls Part Number: IM 1005 Date: January 2018 RoofPak Singlezone Heating and Cooling Units, Models

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

Bluetooth Shielding Instructions

Bluetooth Shielding Instructions Mac mini 2012 Bluetooth Shielding Instructions 1 INTRODUCTION 1.1 STATIC PRECAUTIONS 1.2 TOOLS REQUIRED 2 DISASSEMBLY 3 SHIELDING 4 FAQ 4.1 FAQ 5 CUSTOMER SERVICE 5.1 Before Contacting Customer Service

More information

Installation and Maintenance Manual IM 837-3

Installation and Maintenance Manual IM 837-3 Installation and Maintenance Manual IM 837-3 Group: Controls Part Number: IM 837 Date: December 2017 MicroTech II Chiller BACnet IP/Ethernet Communication Module ACZ Air-Cooled Scroll Condensing Unit AGS

More information

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3 2. MFP SERVER INSTALLATION...5 PREPARATION...5 CONFIGURATION SOLUTION TABLE...5

More information

Longshine Technologie Europe GmbH

Longshine Technologie Europe GmbH Longshine Technologie Europe GmbH www.longshine.de TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3 2. MFP SERVER INSTALLATION...5

More information

MicroTech II Daikin Chiller Unit Controller BACnet Communication Module (MS/TP)

MicroTech II Daikin Chiller Unit Controller BACnet Communication Module (MS/TP) Installation and Maintenance Manual IM 906-2 Group: Controls Part Number: IM 906 Date: December 2010 Supersedes: IM 906-1 MicroTech II Daikin Chiller Unit Controller BACnet Communication Module (MS/TP)

More information

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin: Phase Loss Protection Upgrade In this bulletin: Introduction... 2 Purpose... 2 General... 2 Applicability... 2 HD3070 Phase Loss Protection Upgrade Kit Parts... 2 Preparation... 4 Install the Phase Loss

More information

BACnet /IP to MS/TP Adapter User Guide

BACnet /IP to MS/TP Adapter User Guide BACnet /IP to MS/TP Adapter User Guide Document Revision History: Version 1.0 - Initial Release February, 2010 BACnet/IP to MS/TP Adapter - User Guide 1.0 05DI-UGBRTPB-10 Copyright Distech Controls Inc.

More information

Installation and Maintenance Manual IM 968-4

Installation and Maintenance Manual IM 968-4 Installation and Maintenance Manual IM 968-4 Group: Controls Part Number: IM 968 Date: January 2018 MicroTech III Chiller Unit Controller LonWorks Communication Module Models AGZ and AMZ Trailblazer Air-cooled

More information

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver www.longshine.de TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3

More information

BACnet Router Start-up Guide

BACnet Router Start-up Guide BACnet Router Start-up Guide BAS Router (BACnet Multi-Network Router) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after October 2014 Kernel Version: 6.15 Document Revision: 3 QuickServer

More information

MicroTech II BACnet Communication Module Configuration Tool for McQuay Maverick II Rooftop Unit Controllers

MicroTech II BACnet Communication Module Configuration Tool for McQuay Maverick II Rooftop Unit Controllers Users Manual UM 855 Group: Controls Part Number: UM 855 Date: June 2007 Supersedes: New MicroTech II BACnet Communication Module Configuration Tool for McQuay Maverick II Rooftop Unit Controllers Commercial

More information

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date: Installation- and Operating instructions for CU8880-0010 Ethernet Controller with USB Input Version: 1.4 Date: 2018-04-12 Table of contents Table of contents 1. 2. 3. 4. 5. General instructions 2 Notes

More information

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number:

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number: Minarik Variable Speed AC Motor Drives AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY INSTALLATION INSTRUCTIONS Document Number: 250-0297 These instructions apply to models rated: 7.5 25

More information

AURA SSD FOR MAC PRO. Installation Guide

AURA SSD FOR MAC PRO. Installation Guide AURA SSD FOR MAC PRO Installation Guide CONTENTS Introduction... 1 1.1 System Requirements 1.2 Package Contents 1.3 About This Manual Installation... 2 2.1 Preparing the Mac Pro 2.2 Installing the Aura

More information

BACnet Router Start-up Guide

BACnet Router Start-up Guide BACnet Router Start-up Guide BAS Router (BACnet Multi-Network Router) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after January 2015 Kernel Version: Application Version: Document

More information

2 Mesa Ethernet Dock User s Manual

2 Mesa Ethernet Dock User s Manual owner s manual Mesa Ethernet Dock The Mesa Ethernet Dock is an optional accessory that provides an ethernet port for networking, power input jack, USB client port, and a mounting station for the Mesa Rugged

More information

YSOFT SAFEQ TERMINAL PROFESSIONAL 3.8 USER S GUIDE 1

YSOFT SAFEQ TERMINAL PROFESSIONAL 3.8 USER S GUIDE 1 YSOFT SAFEQ TERMINAL PROFESSIONAL 3.8 USER S GUIDE 1 Copyright 2014 Y Soft Corporation. All rights reserved. Edition 2.0 [EN] Date: 5 October 2014 YSoft SafeQ, the YSoft SafeQ logo, and the Y Soft logo

More information

1-channel MPEG-4 Video Encoder ACD-2100T. Ver User s Manual 0-0

1-channel MPEG-4 Video Encoder ACD-2100T. Ver User s Manual 0-0 1-channel MPEG-4 Video Encoder ACD-2100T Ver. 080619+ User s Manual 0-0 0 0 PRECAUTIONS 1. Read these instructions All the safety and operating instructions should be read before the product is operated.

More information

GPIB-232CT-A IBCL EPROM Installation Guide

GPIB-232CT-A IBCL EPROM Installation Guide NATIONAL INSTRUMENTS The Software is the Instrument Installation Guide GPIB-232CT-A IBCL EPROM Installation Guide This guide describes how to replace the factory-installed EPROM that comes with your GPIB-232CT-A.

More information

CubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions

CubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions CubePro Prosumer 3D Printer Main PCB Replacement Guide Original Instructions 1 INTRODUCTION COPYRIGHT 2014 by All rights reserved. This document is subject to change without notice. This document is copyrighted

More information

OM Operation and Maintenance Manual. Intelligent Equipment for Daikin Applied Trailblazer Air-cooled Scroll Chiller. Models: AGZ-D and AGZ-E

OM Operation and Maintenance Manual. Intelligent Equipment for Daikin Applied Trailblazer Air-cooled Scroll Chiller. Models: AGZ-D and AGZ-E Operation and Maintenance Manual Intelligent Equipment for Daikin Applied Trailblazer Air-cooled Scroll Chiller OM 1241 Group: Controls Part Number: 910166134 Date: June 2015 Models: AGZ-D and AGZ-E Table

More information

MicroTech II Remote I/O Panel Installation Manual

MicroTech II Remote I/O Panel Installation Manual MicroTech II Remote I/O Panel Installation Manual Installation Manual IM 783-2 Group: Controls Part Number: IM 783 Date: November 2006 Supersedes: IM 783-1 Table of Contents Notice... 3 Reference Documents...

More information

Chapter 2. Installing the Chapter 2. Contents

Chapter 2. Installing the Chapter 2. Contents Contents Chapter 2 Installing the 3512 Overview... 2-2 Unpacking... 2-2 Telephone Equipment... 2-3 Customer-Provided Telephone Equipment... 2-3 Telephone Company Procedures and Regulatory Requirements...

More information

D12. 1MP Cube with Fixed lens Hardware User s Manual. (PoE) Ver. 2013/05/07

D12. 1MP Cube with Fixed lens Hardware User s Manual. (PoE) Ver. 2013/05/07 D12 1MP Cube with Fixed lens Hardware User s Manual (PoE) Ver. 2013/05/07 Table of Contents Precautions 3 Safety Instructions... 4 Introduction 6 Features and Benefits... 6 Package Contents... 7 Physical

More information

8-port 10/100Base-TX Switch (INS-806) User s Guide

8-port 10/100Base-TX Switch (INS-806) User s Guide 8-port 10/100Base-TX Switch (INS-806) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means,

More information

Installing the Cisco SFS 3504 Server Switch

Installing the Cisco SFS 3504 Server Switch CHAPTER 3 This chapter describes how to mount your Cisco SFS 3504 Server Switch on a rack, boot the Cisco SFS 3504 Server Switch, and configure basic services. For advanced configuration information, see

More information

MT /12-Slot Digital MultiTasker

MT /12-Slot Digital MultiTasker /12-Slot Digital MultiTasker Welcome! We greatly appreciate your purchase of the MT302-121 12-Slot Digital MultiTasker Enclosure. We are sure you will find it reliable and simple to use. Superior performance

More information

4100/ VDC Converter Installation Instructions

4100/ VDC Converter Installation Instructions 4100/4120-0156 8 VDC Converter Installation Instructions Introduction This publication describes the installation procedure for the 8 VDC Converter. Related Documentation Field Wiring Diagram for 4100

More information

BACnet/IP to BACnet MS/TP Router

BACnet/IP to BACnet MS/TP Router BACnet/IP to BACnet MS/TP Router Features Compact Size Routes between BACnet /IP and BACnet MS/TP networks 10/100Mbps Ethernet Auto-MDIX port Optically isolated MS/TP communications port MS/TP baud rates:

More information

MicroTech II Vertical Self-contained Systems Unit Controller

MicroTech II Vertical Self-contained Systems Unit Controller Installation and Maintenance IM-710 Group: Applied Systems Part Number: IM710 Date: February 2002 MicroTech II Vertical Self-contained Systems Unit Controller Used with McQuay models: SWP and SWT BACK

More information

ELETICS Quickstart Installation Manual

ELETICS Quickstart Installation Manual ELETICS Quickstart Installation Manual Version 2.1 April 22 2016 www.teletics.com 1 Statement of Conformity FCC Class A Notice This device complies with Part 15 of the FCC Rules. Operation is subject to

More information

4170 POS System Installation Guide

4170 POS System Installation Guide 4170 POS System 4170 Installation Guide Thank you for selecting UTC RETAIL s innovative Model 4170 Point of Sale solution! This Installation Guide will help you efficiently install the 4170 POS. The document

More information

Revision History E F G H J K Revision Description: K > Allegion Rebranding.

Revision History E F G H J K Revision Description: K > Allegion Rebranding. Notes: Enter any notes here. These notes must include: how many sides of the paper are printed ink color (usually black, may also be one or two specific colors, such as a Pantone value, or 17.000 8.500

More information

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution! 1170 POS SYSTEM 1170 INSTALLATION GUIDE Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution! This Installation Guide will help you efficiently install the 1170 POS. The document

More information

Perle MCR200 Installation Guide

Perle MCR200 Installation Guide Perle MCR200 Installation Guide P/N 5500322-10 Introduction The Perle MCR200 Chassis is a 2 slot chassis able to accommodate up to 2 Perle Media Converter modules or 1 Media Converter Module and an MCR-MGT

More information

A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address

A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address Requirements A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address Power Up A Reader with an Ethernet adaptor installed and the network cable

More information

LED Maintenance Instructions

LED Maintenance Instructions Chapter 5 LED Maintenance Instructions This guide describes the maintenance procedures for the LED portion of your DayStar or TekStar sign. 1.800.237.3928 stewartsigns.com Rev1802 Intentionally Left Blank

More information

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09. Encoder Firmware V4.06.09 User s Manual Outdoor PTZ Camera Hardware Manual KCM-8211 2013/05/09 1 Table of Contents Precautions... 3 Introduction... 4 List of Models... 4 Package Contents... 5 Safety Instructions...

More information

Quick Installation Guide

Quick Installation Guide Quick Installation Guide For Network Attached Storage Ver.1.1.0.0517 Table of Contents Notices... 3 Safety Precautions... 4 1. Package Contents... 5 2. Hardware Installation Guide... 6 2.1. Hard Disk Installation...

More information

Voice Evacuation Control Panel Main Circuit Board Replacement Product Installation Document

Voice Evacuation Control Panel Main Circuit Board Replacement Product Installation Document Voice Evacuation Control Panel Main Circuit Board Replacement Product Installation Document Document 50795 Rev B 10/10/01 ECN 01-507 This Product Installation Document outlines the replacement of the Main

More information

Technical Manual SMART TRAC PS Card

Technical Manual SMART TRAC PS Card Technical Manual SMART TRAC PS Card Contents Important Safety and Warranty Information 1 Warnings, Cautions and Notes...1 General Safety Precautions - Warnings...2 Important Warranty Information...2 Smart

More information

Obsolete. BR Series USB Tech Kit. B l u e R i d g e. T e c h n o l o g i e s. User Guide. Page 1. Hardware and Software Instructions

Obsolete. BR Series USB Tech Kit. B l u e R i d g e. T e c h n o l o g i e s. User Guide. Page 1. Hardware and Software Instructions Hardware and Software Instructions Page 1 Attention Page 2 This section serves as a notice of the immediate or potential dangers involved when working with the equipment described throughout this manual.

More information

MicroTech II TM Remote I/O Panel Installation Manual

MicroTech II TM Remote I/O Panel Installation Manual Installation Manual IM 783-0 MicroTech II TM Remote I/O Panel Installation Manual Group: Controls Part Number: IM 783-0 Date: February 2004 Supersedes: New 2004 McQuay International Page 2 IM-783 Table

More information

Ethernet Adapter Installation Instructions

Ethernet Adapter Installation Instructions Ethernet Adapter Installation Instructions DOC. #569040000 A 7/30/04 PRINTED IN U.S.A. Disclaimer Logic One is a registered trademark of Novar Controls Corporation. The material in this manual is for information

More information

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH 8 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH WITH 1 PORT 1000BASE-X UPLINK OR 1 PORT 100/1000BASE-X UPLINK 8 PORTS 10/100/1000BASE-T

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service.... 2 Disconnect Power Connections, CTs, and Modbus....

More information

2100 POS System User Guide

2100 POS System User Guide 2100 POS System 2100 User Guide Thank you for selecting UTC RETAIL s innovative Model 2100 Point of Sale solution! This guide is designed to acquaint you with the features and functionality of the 2100

More information

Model#: IN-DO3MIRF 3MP Outdoor Dome with True Day/Night, IR, Basic WDR, Fixed lens

Model#: IN-DO3MIRF 3MP Outdoor Dome with True Day/Night, IR, Basic WDR, Fixed lens Model#: IN-DO3MIRF 3MP Outdoor Dome with True Day/Night, IR, Basic WDR, Fixed lens Hardware User Manual (PoE) 2013/03/06 Table of Contents Precautions... 3 Introduction... 4 Package Contents... 4 Safety

More information

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

ALPHA Plus and A3 ALPHA Switchboard Meters with the CPS Power Supply

ALPHA Plus and A3 ALPHA Switchboard Meters with the CPS Power Supply October 2012 IL42-4031C ALPHA Plus and A3 ALPHA Switchboard Meters with the CPS Power Supply General This leaflet contains general installation instructions for ALPHA Plus and A3 ALPHA meters with the

More information

1. Package contents. 2. Connecting ADSL modem and wireless router

1. Package contents. 2. Connecting ADSL modem and wireless router 1. Package contents WL-500W wireless router x 1 Power adapter x 1 Utility CD x 1 RJ45 cable x 1 Quick Start Guide x 1 2. Connecting ADSL modem and wireless router 1) Cable connection Wall power outlet

More information

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual 5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800 User's Manual Trademarks Copyright PLANET Technology Corp. 2006. Contents subject to which revision without prior notice. PLANET is a registered

More information

MicroTech 2000 Water Source Heat Pump Unit Controller

MicroTech 2000 Water Source Heat Pump Unit Controller Installation Manual IM 660-4 Group: Controls Part Number: IM 660 Date: June 2012 Supersedes: IM 660-3 MicroTech 2000 Water Source Heat Pump Unit Controller NOTICE Use this manual to physically install

More information

FC-25/50DA Main Circuit Board Replacement Product Installation Document

FC-25/50DA Main Circuit Board Replacement Product Installation Document FC-25/50DA Main Circuit Board Replacement Product Installation Document Document 51875 Rev A 10/12/01 ECN 01-506 This Product Installation Document outlines the replacement of the Main Circuit Board for

More information

User s Manual. 8-channel MPEG-4 1U Video Encoder ACD Ver

User s Manual. 8-channel MPEG-4 1U Video Encoder ACD Ver 8-channel MPEG-4 1U Video Encoder ACD-2300 User s Manual Ver.080331 0 0 PRECAUTIONS 1. Read these instructions All the safety and operating instructions should be read before the product is operated.

More information

3G Cell Modem Upgrade

3G Cell Modem Upgrade 3G Cell Modem Upgrade For BaseStation 1000 Irrigation Controllers in Pedestal Enclosures October 7, 2014 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com Phone 208-323-1634 FAX 208-323-1834

More information

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC KPW-T2P25 Industrial IEEE 802.3at High Power PoE Splitter User s Manual DOC.121011-1- (C) 2012 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any

More information

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents. User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply

More information

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN Voltage Regulators MN225074EN Effective March 2017 Supersedes January 2012 (S225-40-7) RS-485 digital communications accessory board installation and operation instructions COOPER POWER SERIES DISCLAIMER

More information

Network USB over IP Server With 1-USB2.0 Port. User Manual V1.0

Network USB over IP Server With 1-USB2.0 Port. User Manual V1.0 Network USB over IP Server With 1-USB2.0 Port User Manual V1.0 1 2 TABLE OF CONTENTS COPYRIGHT...4 1. INTRODUCTION...5 PRODUCT OVERVIEW...5 COMPONENTS AND FEATURES...5 HARDWARE INSTALLATION...5 2. THE

More information

2190 POS System User Guide

2190 POS System User Guide 2190 POS System 2190 User Guide Thank you for selecting UTC RETAIL s innovative Model 2190 Point of Sale solution! This guide is designed to acquaint you with the features and functionality of the 2190

More information

MicroTech Series-100 Application Specific Controller

MicroTech Series-100 Application Specific Controller Installation & Maintenance Data IM 657-1 Group: Controls Part Number: 594861Y Date: March 1998 MicroTech Series-100 Application Specific Controller a0196 1998 McQuay International Contents Contents...2

More information

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery. ASTCPOEK PoE/FPR Kit for Auto-Sync Time Clock The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery. The ASTCPOEK Kit provides Power over Ethernet with Full Power

More information

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2

More information

For More Product Information On This Other Arcade and Amusment Products, Visit :

For More Product Information On This Other Arcade and Amusment Products, Visit : Table of Contents Contents General Remark...2 Table of Contents...3 Chapter 01 - Preface...4 Precaution for Game Operation... 4 Safety... 5 Environmental Conditions... 5 FCC Notices (United States)...

More information