VIPA Accessories. Teleservice module 900-2E651 Manual

Size: px
Start display at page:

Download "VIPA Accessories. Teleservice module 900-2E651 Manual"

Transcription

1 VIPA Accessories Teleservice module 900-2E651 Manual HB39E_TM RE_900-2E651 Rev. 10/16 April 2010

2 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed or used except in accordance with applicable agreements. This material is protected by the copyright laws. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to VIPA), except in accordance with applicable agreements, contracts or licensing, without the express written consent of VIPA and the business management owner of the material. For permission to reproduce or distribute, please contact: VIPA, Gesellschaft für Visualisierung und Prozessautomatisierung mbh Ohmstraße 4, D Herzogenaurach, Germany Tel.: +49 (91 32) Fax.: Note Every effort has been made to ensure that the information contained in this document was complete and accurate at the time of publishing. Nevertheless, the authors retain the right to modify the information. This customer document describes all the hardware units and functions known at the present time. Descriptions may be included for units which are not present at the customer site. The exact scope of delivery is described in the respective purchase contract. CE Conformity Hereby, VIPA GmbH declares that the products and systems are in compliance with the essential requirements and other relevant provisions of the following directives: 2004/108/EC Electromagnetic Compatibility Directive 2006/95/EC Low Voltage Directive Conformity is indicated by the CE marking affixed to the product. Conformity Information For more information regarding CE marking and Declaration of Conformity (DoC), please contact your local VIPA customer service organization. Trademarks VIPA, SLIO, System 100V, System 200V, System 300V, System 300S, System 400V, System 500S and Commander Compact are registered trademarks of VIPA Gesellschaft für Visualisierung und Prozessautomatisierung mbh. SPEED7 is a registered trademark of profichip GmbH. SIMATIC, STEP, SINEC, S7-300 and S7-400 are registered trademarks of Siemens AG. Microsoft und Windows are registered trademarks of Microsoft Inc., USA. Portable Document Format (PDF) and Postscript are registered trademarks of Adobe Systems, Inc. All other trademarks, logos and service or product marks specified herein are owned by their respective companies. Information product support Contact your local VIPA Customer Service Organization representative if you wish to report errors or questions regarding the contents of this document. If you are unable to locate a customer service center, contact VIPA as follows: VIPA GmbH, Ohmstraße 4, Herzogenaurach, Germany Telefax: documentation@vipa.de Technical support Contact your local VIPA Customer Service Organization representative if you encounter problems with the product or have questions regarding the product. If you are unable to locate a customer service center, contact VIPA as follows: VIPA GmbH, Ohmstraße 4, Herzogenaurach, Germany Telephone: /1180 (Hotline) support@vipa.de

3 Contents Contents About this manual... 1 Safety information... 2 Chapter 1 Assembly and installation guidelines Safety information for Users Installation of the SIM card Installation dimensions Assembly Cabling Installation guidelines Chapter 2 Hardware description Properties Structure Technical Data Chapter 3 Deployment TM Fast introduction Assembly Cabling TM - Configuration - ebuddy TM - Reset TM - Web page TM - PLC linking TM - Project integration - PG/PC interface via NetPro TM - Project integration - PG/PC interface via evcom Installation of the SIM card Deployment of Tags Teleservice via telephone with MPI gateway Teleservice via Callback function Teleservice via SMS Appendix...A-1 Index...A-1 HB39E - TM - RE_900-2E651 - Rev. 10/16 i

4 Contents ii HB39E - TM - RE_900-2E651 - Rev. 10/16

5 About this manual About this manual Important note! The information in this manual should simplify you the deployment of remote controlling VIPA PLCs. More information concerning this may be found in German and English at: support.ewon.biz This Teleservice module TM-E from VIPA is constructed in the same way as the module "ewon2001". Overview Chapter 1: Assembly and installation guidelines In this chapter you will find all information, required for assembly and installation of the Teleservice module (TM). Chapter 2: Hardware description Here the hardware components of the Teleservice module (TM) are more described. The technical data are at the end of this chapter. Chapter 3: Deployment This chapter concerns on the deployment of the Teleservice module (TM) from VIPA with a PLC. With the fast introduction you will get an overview about the possibilities of the Teleservice module. Another part of this chapter is the configuration of the TM by means of the integrated Web page. This chapter ends with the possibilities of the teleservice functions. HB39E - TM - RE_900-2E651 - Rev. 10/16 1

6 About this manual Objective and contents This manual describes the Teleservice module TM-E GSM/GPRS Router Quadband from VIPA. It contains a description of the construction, project implementation and usage. This manual is part of the documentation package with order number VIPA HB39E_TM and relevant for: Product Order number as of state: TM-FW TM-E GSM/GPRS Router Quadband VIPA 900-2E Target audience The manual is targeted at users who have a background in automation technology. Structure of the manual The manual consists of chapters. Every chapter provides a self-contained description of a specific topic. Guide to the document The following guides are available in the manual: an overall table of contents at the beginning of the manual an overview of the topics for every chapter an index at the end of the manual. Availability The manual is available in: printed form, on paper in electronic form as PDF-file (Adobe Acrobat Reader) Icons Headings Important passages in the text are highlighted by following icons and headings: Danger! Immediate or likely danger. Personal injury is possible. Attention! Damages to property is likely if these warnings are not heeded. Note! Supplementary information and useful tips 2 HB39E - TM - RE_900-2E651 - Rev. 10/16

7 Safety information Safety information Applications conforming with specifications The Teleservice module is constructed and produced for: communication and process control general control and automation applications industrial applications operation within the environmental conditions specified in the technical data installation into a cubicle Danger! This device is not certified for applications in in explosive environments (EX-zone) Documentation The manual must be available to all personnel in the project design department installation department commissioning operation The following conditions must be met before using or commissioning the components described in this manual: Modification to the process control system should only be carried out when the system has been disconnected from power! Installation and modifications only by properly trained personnel The national rules and regulations of the respective country must be satisfied (installation, safety, EMC...) Disposal National rules and regulations apply to the disposal of the unit! HB39E - TM - RE_900-2E651 - Rev. 10/16 3

8 Safety information 4 HB39E - TM - RE_900-2E651 - Rev. 10/16

9 Chapter 1 Assembly and installation guidelines Chapter 1 Assembly and installation guidelines Overview In this chapter you will find all information, required for assembly and installation of the Teleservice module (TM). Content Topic Page Chapter 1 Assembly and installation guidelines Safety information for Users Installation of the SIM card Installation dimensions Assembly Cabling Installation guidelines HB39E - TM - RE_900-2E651 - Rev. 10/16 1-1

10 Chapter 1 Assembly and installation guidelines Safety information for Users Handling of electrostatic sensitive modules VIPA modules make use of highly integrated components in MOS- Technology. These components are extremely sensitive to over-voltages that can occur during electrostatic discharges. The following symbol is attached to modules that can be destroyed by electrostatic discharges. The Symbol is located on the module, the module rack or on packing material and it indicates the presence of electrostatic sensitive equipment. It is possible that electrostatic sensitive equipment is destroyed by energies and voltages that are far less than the human threshold of perception. These voltages can occur where persons do not discharge themselves before handling electrostatic sensitive modules and they can damage components thereby, causing the module to become inoperable or unusable. Modules that have been damaged by electrostatic discharges can fail after a temperature change, mechanical shock or changes in the electrical load. Only the consequent implementation of protection devices and meticulous attention to the applicable rules and regulations for handling the respective equipment can prevent failures of electrostatic sensitive modules. Shipping of electrostatic sensitive modules Measurements and alterations on electrostatic sensitive modules Modules must be shipped in the original packing material. When you are conducting measurements on electrostatic sensitive modules you should take the following precautions: Floating instruments must be discharged before use. Instruments must be grounded. Modifying electrostatic sensitive modules you should only use soldering irons with grounded tips. Attention! Personnel and instruments should be grounded when working on electrostatic sensitive modules. 1-2 HB39E - TM - RE_900-2E651 - Rev. 10/16

11 Chapter 1 Assembly and installation guidelines Installation of the SIM card Caution! Please regard the SIM card may only be plugged if you have configured it at the TM Web page, before. Else your SIM card may be blocked! Preconditions For the further approach it is precondition that you have access to the Web page of the TM and you have a valid GSM SIM card with PIN. Configuration at the Web page Open the Web page of the Teleservice module. Navigate via Configuration > System setup to the page "Communication". Open at the navigation tree Interfaces the page "Modem". At "GSM PIN" type in the pin number, which is delivered with your SIM card. Leave every values at default setting and click at [Update]. Installing the SIM card The slot for the SIM card is located at the rear-side of the module. The SIM card should be installed before the assembly. The installation happens with the following approach: Switch off the power supply of the Teleservice module. Insert the SIM card as shown to the SIM card slot. Please regard here the correct positioning! For taking the SIM cart push the eject button with a pointed object. The eject button may be found above the card slot. HB39E - TM - RE_900-2E651 - Rev. 10/16 1-3

12 Chapter 1 Assembly and installation guidelines Commissioning with SIM card Connect if not just happened a suited antenna. The Teleservice module has a an antenna jack. Here a GSM dual band antenna may be connected. The TM is delivered without any antenna. You may get a suited antenna from VIPA. You find the order numbers in this manual under "Properties". Switch-on again the power supply of the TM. With a cold restart it may last up to 2 minutes until the GSM modem is been rebooted and initialized. Open the Web page of the Teleservice module. Navigate via Configuration > System setup to the page "Communication". Open in the navigation tree Interfaces the page "Modem". If you have made everything correctly and your GSM modem is connected to a mobile network, the following parameters are listed: Modem detected This parameter shows you the type of the internal modem. Here the text "internal Multiband GSM" should be shown. Signal level Here the signal level is shown. This value is determined once a minute. For a communication connection this value should be higher than 17. A value of 25 corresponds to a good connection. If a value is higher than 30 this correspond to an excellent connection. A signal level of 0 indicates a non existing mobile network. Network "Home Network" is shown if the SIM card is operated in the country of which the SIM card is from. If the Teleservice module is operated in an other country, "Roaming" is shown. Otherwise the following error messages may be displayed with his parameter: - "SIM card error!" if SIM card is missing - "PIN code error!" if PIN is faulty - "in operation..." the modem tries to connect to a mobile network. Operator Here the name of your mobile network provider is listed. 1-4 HB39E - TM - RE_900-2E651 - Rev. 10/16

13 Chapter 1 Assembly and installation guidelines Installation dimensions Dimensions Make sure that a clearance of at least 100mm exists above and 70mm below the middle of the bus rail. 138 mm 150 mm 64 mm 70 mm 100 mm Dimensions assembled mm 89 mm 132 mm HB39E - TM - RE_900-2E651 - Rev. 10/16 1-5

14 Chapter 1 Assembly and installation guidelines Assembly General The modules are installed on a profile rail. You may use the following standard 35mm profile rail: 35 mm 1 mm 7,5 mm 35 mm 1,5 mm 15 mm 27 mm 27 mm Assembly procedure The following sequence represents the assembly procedure as viewed from the side. Install the profile rail. Make sure that a clearance of at least 100mm exists above and 70mm below the middle of the profile rail. 70 mm 100 mm Clack Insert the module that you are installing into the profile rail at an angle of about 45 degrees from the top and rotate the module into place until it clicks into the profile rail with an audible click. 1-6 HB39E - TM - RE_900-2E651 - Rev. 10/16

15 Chapter 1 Assembly and installation guidelines Removal procedure The following sequence shows the steps required for the removal of modules in a side view. For the removal take the module at the bottom and pull it forward with a strong jerk. Now withdraw the module with a slight rotation to the top. HB39E - TM - RE_900-2E651 - Rev. 10/16 1-7

16 Chapter 1 Assembly and installation guidelines Cabling Overview At the upper side of the Teleservice module there are connectors for power supply and digital inputs/outputs. The output is designed as low-side output and may be configured. The connectors are plugs with screw contacts. If connected the plugs may be fixed with screws. The I/Os are controlled by Tags. An example may be found at the chapter "Deployment" at "Deployment of Tags". Power supply The Teleservice module is to be supplied by DC V ±20%. 2 1 Pin Name Meaning V DC DC V ±20% 1 GND Ground power supply DI/DO connection The output is designed as low-side output and may be configured Pin Name Meaning 5 DI Digital input DC 0/24V "0": V DC "1": 10V... 30V DC 4 DI_GND DI ground (isolated) 3 DO_VDC DO load voltage DC 24V 2 DO Digital output DC 24V, 0.2A Low-side output 1 DO_GND DO ground DI/DO wiring schematic diagram DI 5 DI_GND 4 + DC 24V - Output DO 3 DO_VDC DO_VDC 3 Optocoupler 2 DO_OC + DC 24V DO 2 DO_GND 1 + DC 24V - 1 DO_GND HB39E - TM - RE_900-2E651 - Rev. 10/16

17 Chapter 1 Assembly and installation guidelines Installation guidelines General The installation guidelines contain information about the possible interference causes. Here we describe possible ways of interference that may disturb the controlling system and how you have to approach shielding and screening issues to ensure the electromagnetic compatibility (EMC). What is EMC? Electromagnetic digestibility (EMC) means the ability of an electrical device, to function error free in an electromagnetic environment without being interferenced res. without interferencing the environment. The Teleservice module is developed for applications in harsh industrial environments and they comply with EMC requirements to a large degree. In spite of this you should implement an EMC strategy before installing your SPS and the Teleservice module, which should include any possible source of interference. Possible interference causes Electromagnetic interferences may interfere your control via different ways: Fields I/O signal conductors Bus system Current supply Protected earth conductor Depending on the spreading medium (lead bound or lead free) and the distance to the interference cause, interferences to your control occur by means of different coupling mechanisms. One differs: galvanic coupling capacitive coupling inductive coupling radiant coupling HB39E - TM - RE_900-2E651 - Rev. 10/16 1-9

18 Chapter 1 Assembly and installation guidelines Basic rules for EMC In the most times it is enough to take care of some elementary rules to guarantee the EMC. Please regard the following basic rules when installing your PLC. Take care of a correct area-wide grounding of the inactive metal parts when installing your components. - Install a central connection between the ground and the protected earth conductor system. - Connect all inactive metal extensive and impedance-low. - Please try not to use aluminum parts. Aluminum is easily oxidizing and is therefore less suitable for grounding. When cabling, take care of the correct line routing. - Organize your cabling in line groups (high voltage, current supply, signal and data lines). - Always lay your high voltage lines and signal res. data lines in separate channels or bundles. - Route the signal and data lines as near as possible beside ground areas (e.g. suspension bars, metal rails, tin cabinet). Proof the correct fixing of the lead isolation. - Data lines must be laid isolated. - Analog lines must be laid isolated. When transmitting signals with small amplitudes the one sided laying of the isolation may be favorable. - Lay the line isolation extensively on an isolation/protected earth conductor rail directly after the cabinet entry and fix the isolation with cable clamps. - Make sure that the isolation/protected earth conductor rail is connected impedance-low with the cabinet. - Use metallic or metalized plug cases for isolated data lines. In special use cases you should appoint special EMC actions. - Wire all inductivities with erase links, which are addressed by your PLC. - For lightening cabinets you should prefer incandescent lamps and avoid luminescent lamps. Create a homogeneous reference potential and ground all electrical operating supplies when possible. - Please take care for the targeted employment of the grounding actions. The grounding of the PLC is a protection and functionality activity. - Connect installation parts and cabinets with your PLC in star topology with the isolation/protected earth conductor system. So you avoid ground loops. - If potential differences between installation parts and cabinets occur, lay sufficiently dimensioned potential compensation lines HB39E - TM - RE_900-2E651 - Rev. 10/16

19 Chapter 1 Assembly and installation guidelines Isolation of conductors Electrical, magnetic and electromagnetic interference fields are weakened by means of an isolation, one talks of absorption. Via the isolation rail, that is connected conductive with the rack, interference currents are shunt via cable isolation to the ground. Hereby you have to make sure, that the connection to the protected earth conductor is impedance-low, because otherwise the interference currents may appear as interference cause. When isolating cables you have to regard the following: If possible, use only cables with isolation tangle. The hiding power of the isolation should be higher than 80%. Normally you should always lay the isolation of cables on both sides. Only by means of the both-sided connection of the isolation you achieve high quality interference suppression in the higher frequency area. Only as exception you may also lay the isolation one-sided. Then you only achieve the absorption of the lower frequencies. A one-sided isolation connection may be convenient, if: - the conduction of a potential compensating line is not possible - analog signals (some mv res. µa) are transferred - foil isolations (static isolations) are used. With data lines always use metallic or metalized plugs for serial couplings. Fix the isolation of the data line at the plug rack. Do not lay the isolation on the PIN 1 of the plug bar! At stationary operation it is convenient to strip the insulated cable interruption free and lay it on the isolation/protected earth conductor line. To fix the isolation tangles use cable clamps out of metal. The clamps must clasp the isolation extensively and have well contact. Lay the isolation on an isolation rail directly after the entry of the cable in the cabinet. Lead the isolation further on to the PLC and don't lay it on there again! Please regard at installation! At potential differences between the grounding points, there may be a compensation current via the isolation connected at both sides. Remedy: Potential compensation line HB39E - TM - RE_900-2E651 - Rev. 10/

20 Chapter 1 Assembly and installation guidelines 1-12 HB39E - TM - RE_900-2E651 - Rev. 10/16

21 Chapter 2 Hardware description Chapter 2 Hardware description Overview Here the hardware components of the Teleservice module (TM) are more described. The technical data are at the end of this chapter. Content Topic Page Chapter 2 Hardware description Properties Structure Technical Data HB39E - TM - RE_900-2E651 - Rev. 10/16 2-1

22 Chapter 2 Hardware description Properties Overview Properties The TM-E is an intelligent Teleservice module. This module makes simple and safe communication with your machines and plants possible via telephone respectively internet. Values of your plant may be observed and appropriate reactions to limit exceeds may be configured. Here e.g. plant data may be collected and sent via mail. Due to the integrated Web page, for configuration there is no additional software necessary. Due to the predefined server the embedding to a VIPA PLC may be established problem-free. The TM may be integrated as PG/OP interface to the Siemens SIMATIC manager by means of a station file. Transparent Ethernet-Gateway with TCP/IP Router Sending alarms by and SMS (only via free SMS provider) up to 20 Ethernet sessions simultaneous Programmable gateway by BASIC fully customizable web pages (in HTML) integrated alarm management RS485 MPI/Profibus DP interface RJ45 Ethernet interface integrated GSM/GPRS Quadband-Modem - GSM 900MHz / DCS 1800MHz and GSM 850MHz / PCS 1900MHz Slot for SIM card PWR MPI DI VIPA 900-2E651 USER MODEM DO ETHERNET LAN MPI LINE WAN/PPP Order data Type Order number Description TM-E GSM/GPRS VIPA 900-2E651 DC V, GSM/GPRS, MPI/Profibus DP, Ethernet Router Quadband RJ45, router functions, DI 1xDC 24V, DO 1xDC 24V 0.2A TM-Antenna VIPA 900-0AA00 Dipole antenna with SMA plug TM-Antenna VIPA 900-0AB50 Mobile antenna incl. 5m cable and SMA plug TM-Antenna VIPA 900-0AQ50 Rod antenna incl. 5m cable and SMA plug 2-2 HB39E - TM - RE_900-2E651 - Rev. 10/16

23 Chapter 2 Hardware description Structure TM-E GSM/GPRS Router Quadband PWR MPI DI LAN 1 2 VIPA 900-2E651 USER MODEM DO ETHERNET [1] SMA antenna jack with male thread [2] Connector for digital I/O [3] Connector for DC V power supply [4] Earthing screw [5] LEDs [6] Reset button [7] Slot for SIM card [8] LAN RJ45 Ethernet interface [9] RS485 MPI/Profibus DP interface [10] not connected 9 MPI 10 WAN/PPP LINE Components LEDs At the front-side of the Teleservice module there are two rows of LEDs. The following table shows you the usage of the LEDs and the according colors: PWR MPI DI USER MODEM DO Label Color Meaning PWR green Power supply is active. USER green blinks: The TM module is ready for communication (ca. 20s after PowerOn). red red/green blinks: IP address not valid (just exist). blinks alternating: The TM module is just waiting for an IP address during boot-up. The LED is also used with the Reset. More about this may be found at "TM - Reset". MPI green blinks: The TM module is communicating with the PLC via MPI. MODEM green on: The modem of the TM module is active. DI green on: The digital input of the TM module is "1". DO green on: The digital output of the TM module is "1". HB39E - TM - RE_900-2E651 - Rev. 10/16 2-3

24 Chapter 2 Hardware description RJ45 Ethernet interface You may connect your Teleservice module to Ethernet by the RJ45 interface. Via Ethernet the integrated Web page of the TM may be accessed for according configurations. The interface is automatically adapting to the transfer rate 10 or 100Mbit/s. The jack has the following assignment: LINK ACT 8-pole RJ45 jack: Pin Assignment 1 Transmit + 2 Transmit - 3 Receive Receive Linking to Ethernet Connect your PC to your TM via Ethernet. Here either a crossed cable or a switch may be used. An active link via Ethernet is shown by the Teleservice module with the upper green "LINK" led. Blinks the lower green "ACT" led the TM module communicates via Ethernet (activity). The TM is delivered with the following IP address parameters: IP address: Subnet mask: To change the IP address parameters the configuration tool "ebuddy" from VIPA may be used. 2-4 HB39E - TM - RE_900-2E651 - Rev. 10/16

25 Chapter 2 Hardware description MPI/Profibus DP interface The Teleservice module is connected to your PLC CPU via this interface. The interface is designed as RS485 jack and has the following assignment: pole SubD jack: Pin Assignment 1 n.c. 2 n.c. 3 RxD/TxD (line B) 4 n.c. 5 GND 6 n.c. 7 n.c. 8 RxD/TxD (line A) 9 n.c. Reset PWR MPI DI VIPA 900-2E6x1 USER MODEM DO A reset at the Teleservice module may be initiated by the Reset button. The Reset button is allocated below the LEDs behind an opening. Please use for operation a pointed object. With the reset (user reset) extra created Web pages and Tag configurations are erased. Here the communication settings are still remaining. LAN MPI WAN/PPP ETHERNET LINE For a complete reset please contact the VIPA support. More about the deployment of the Reset button may be found at "TM - Reset". Caution! An unauthorized complete reset, which possibly was not carefully executed, leads automatically to the expiring of the warranty! Then the device must be sent back to VIPA for reprogramming HB39E - TM - RE_900-2E651 - Rev. 10/16 2-5

26 Chapter 2 Hardware description Connector power supply 2 1 The Teleservice module is to be power supplied by DC V ±20%. Here the power consumption amounts to W. For power supply there is a 2-pin connector at the upper side of the TM module. The connector is a plug with screw contacts. If connected the plugs may be fixed with screws. The connector has the following assignment: Pin Name Meaning V DC DC V ±20% 1 GND Ground power supply Connector digital I/O For the digital inputs/outputs there is a connector at the upper side of the Teleservice module. The output is designed as low-side output and may accordingly be configured. The connector is a plug with screw contacts. If connected the plugs may be fixed with screws. The I/Os are controlled by Tags. An example may be found at the chapter "Deployment" at "Deployment of Tags" Pin Name Meaning 5 DI Digital input DC 0/24V "0": V DC "1": 10V... 30V DC 4 DI_GND DI ground (isolated) 3 DO_VDC DO load voltage DC 24V 2 DO Digital output DC 24V, 0.2A Low-side output 1 DO_GND DO ground DI/DO wiring schematic diagram DI 5 DI_GND 4 + DC 24V - Output DO 3 DO_VDC DO_VDC 3 Optocoupler 2 DO_OC + DC 24V DO 2 DO_GND 1 + DC 24V - 1 DO_GND HB39E - TM - RE_900-2E651 - Rev. 10/16

27 Chapter 2 Hardware description Antenna jack Portable antenna The Teleservice module has an antenna jack. Here antennas of the type GSM 900MHz / DCS 1800MHz respectively GSM 850MHz / PCS 1900MHz, dual band or quad band may be connected. The consignment of the TM does not include an antenna. A suited antenna may be ordered by VIPA. The antenna is provided with a SMA plug. The coaxial built SMA plug (straight medium adaptor) is a miniature HF plug with a threaded connector that excels by high HF denseness. In the standard version the plug has a swivel nut with female thread and a pin. The SMA jack at the TM is with its male thread and the calyx the complement for assembly. The portable antenna is a short rod antenna that is mounted without cable directly at the module via the SMA plug. The antenna may be angled and turned into any direction. 240 mm Slot for the SIM card The slot for a cellular mobile telephony SIM card is located at the rear-side of the module. Caution! Please regard the SIM card may only be plugged if you have configured it at the Teleservice module Web page, before. Else your SIM card may be blocked! More about the installation of a SIM card may be found in the chapter "Deployment" at "Installation of the SIM card". HB39E - TM - RE_900-2E651 - Rev. 10/16 2-7

28 Chapter 2 Hardware description Technical Data TM-E GSM/GPRS Router Quadband Electrical Data VIPA 900-2E651 Power supply (rated value) DC V ±20% Power consumption W Nominal current max. 300mA Mark of conformity and certification CE Hardware Memory 8Mbyte SDRAM, 8Mbyte Flash Real time clock Manual setting by Webinterface or automatically by NTP Server, without Battery Environment conditions Position of installation horizontal/vertical Operating temperature C Relative humidity 80% (no condensation) Storage /Transport temperature -20 up to +60 C Interfaces Ethernet Isolation tested with RJ45 Ethernet 10/100 BaseTX; 1.5kV MPI/Profibus-DP RS485 isolated Slot for SIM card Integrated GSM/GPRS modem Bands Quad band: GSM 900MHz / DCS 1800MHz and GSM 850MHz / PCS 1900MHz GPS Class Class 10 Baud rate max bit/s Antenna connector SMA-F Digital I/Os Input 1xDI 0/24V DC Output (Low side) 1xDO DC 24V, 0.2A Isolation tested with 3.5kV Data record Protocols Modbus RS485, Modbus TCP, Unitelway, DF1, PPI MPI (on board) and serial ASCII Dimensions and weight Dimension front (WxHxD) 39 x 129 x 108mm Weight 300g 2-8 HB39E - TM - RE_900-2E651 - Rev. 10/16

29 Chapter 4 Deployment TM Chapter 3 Deployment TM Overview This chapter concerns on the deployment of the Teleservice module (TM) from VIPA with a PLC. With the fast introduction you will get an overview about the possibilities of Teleservice. Another part of this chapter is the configuration of the TM module by means of the integrated Web page. This chapter ends with the possibilities of the teleservice functions. Content Topic Page Chapter 3 Deployment TM Fast introduction Assembly Cabling TM - Configuration - ebuddy TM - Reset TM - Web page TM - PLC linking TM - Project integration - PG/PC interface via NetPro TM - Project integration - PG/PC interface via evcom Installation of the SIM card Deployment of Tags Teleservice via telephone with MPI gateway Teleservice via Callback function Teleservice via SMS HB39E - TM - RE_900-2E651 - Rev. 10/16 3-1

30 Chapter 4 Deployment TM Fast introduction Important note! The information in this manual should simplify you the deployment of remote controlling VIPA PLCs. More information concerning this may be found in German and English at: support.ewon.biz Power supply The Teleservice module is to be supplied with DC V ±20%. The connection is established by a plug. This may be found at the upper side of the module and has the following allocation: Pin Name Meaning V DC DC V ±20% 1 1 GND Ground power supply IP address parameters on delivery For the access to the TM valid IP address parameters are necessary. The IP addresses are assigned by the network administrator and must be coordinated with him. The TM is delivered with the following IP address parameters: IP address: Subnet mask: To change the IP address parameters the configuration tool "ebuddy" from VIPA may be used. Caution! For every Teleservice module is delivered with the IP address you must not connect more than one new TM module at one time. First commissioning: Connect the new TM with the network, assign TCP/IP address parameters. Now you may connect the next new TM and so on... Linking to Ethernet Connect your PC to your TM module via Ethernet. Here either a crossed cable or a switch may be used. An active link via Ethernet is shown by the TM module with the upper green led on the Ethernet interface. 3-2 HB39E - TM - RE_900-2E651 - Rev. 10/16

31 Chapter 4 Deployment TM Access via ebuddy The software tool "ebuddy" may be found at the download area of For installation execute ebuddysetup.exe and follow the instructions. Start ebuddy. Switch to the list view with "Switch to list mode". Here every TM available in you network is listed. By selecting the corresponding TM at the list, the following functions are available by the context menu (right click): - Changing respectively entering the IP address parameters - Loading respectively executing a firmware update - Backup respectively restoring of an application - Access to the integrated web page of the Teleservice module Access to the Web page Open the Web page of the corresponding TM. After entering User name and Password the web page of the corresponding TM is opened. Access parameters User name: Password: adm adm HB39E - TM - RE_900-2E651 - Rev. 10/16 3-3

32 Chapter 4 Deployment TM Access to the VIPA PLC Connect your CPU to the TM via MPI. Switch on the power supply of the CPU and switch the CPU to RUN. Open the Web page of the corresponding TM. Open with Configuration > I/O server config. the page for adjusting an I/O server. Set as I/O server "S73&400". To access the VIPA PLC enter the following parameters: MPI destination node: 2 (standard) Baud rate: Reply timeout: 3000 (Standard) MPI address: 0 (Standard) Highest MPI station address: 31 (Standard) Topic A: enabled Global device address: MPI, # (with #: MPI address CPU) Poll rate: 2000 MS (Standard) To confirm click at [Update config]. Now the CPU may be accessed via the TM. Establish a Tag In a Tag the storage areas of you PLC may be defined. These storage areas may R/W accessed by the Tag. To establish a Tag open at the Web page the page "Tag setup" and click at "Create new Tag...". Enter the following parameters: Tag name: Test Server name: S73&400 Topic name: A Address: MW0 Type: Boolean Otherwise leave the standard setting and click at [Add/Update...]. Switch with Main menu > View I/O to the Tag list. Enter a new value for the Tag "Test" and click at [Update]. Now this value is set and may be transferred to the CPU with clicking to [Update] in the head line. If the new value is accepted by the CPU, so the communication between the TM module and the CPU is secured. Caution! Please regard the SIM card may only be plugged if you have configured it at the TM Web page, before. Else your SIM card may be blocked! These steps are more described at the following pages. 3-4 HB39E - TM - RE_900-2E651 - Rev. 10/16

33 Chapter 4 Deployment TM Assembly General The modules are installed on a profile rail. You may use the following standard 35mm profile rail: 35 mm 1 mm 7,5 mm 35 mm 1,5 mm 15 mm 27 mm 27 mm Assembly procedure The following sequence represents the assembly procedure as viewed from the side. Install the profile rail. Make sure that a clearance of at least 100mm exists above and 70mm below the middle of the profile rail. 70 mm 100 mm Clack Insert the module that you are installing into the profile rail at an angle of about 45 degrees from the top and rotate the module into place until it clicks into the profile rail with an audible click. HB39E - TM - RE_900-2E651 - Rev. 10/16 3-5

34 Chapter 4 Deployment TM Cabling Overview At the upper side of the Teleservice module there are connectors for power supply and digital inputs/outputs. The output is designed as low-side output and may be configured. The connectors are plugs with screw contacts. If connected the plugs may be fixed with screws. The I/Os are controlled by Tags. An example may be found at the chapter "Deployment" at "Deployment of Tags". Power supply The Teleservice module is to be supplied by DC V ±20%. 2 1 Pin Name Meaning V DC DC V ±20% 1 GND Ground power supply DI/DO connection The output is designed as low-side output and may be configured Pin Name Meaning 5 DI Digital input DC 0/24V "0": V DC "1": 10V... 30V DC 4 DI_GND DI ground (isolated) 3 DO_VDC DO load voltage DC 24V 2 DO Digital output DC 24V, 0.2A Low-side output 1 DO_GND DO ground DI/DO wiring schematic diagram DI 5 DI_GND 4 + DC 24V - Output DO 3 DO_VDC DO_VDC 3 Optocoupler 2 DO_OC + DC 24V DO 2 DO_GND 1 + DC 24V - 1 DO_GND HB39E - TM - RE_900-2E651 - Rev. 10/16

35 Chapter 4 Deployment TM TM - Configuration - ebuddy Overview To deploy the Teleservice module, the VIPA software tool "ebuddy" is necessary. With this new IP address parameters may be assigned to the TM; you may load and transfer new firmware, backup/restore applications and access the integrated web page of the TM. Installation The software tool "ebuddy" may be found at the download area of For installation execute ebuddysetup.exe and follow the instructions. Wizard mode List mode Connect the Teleservice module via Ethernet and switch on its power supply. Start ebuddy. This always starts in the last used mode. Wizard mode Here the following functions are available: Set or modify the IP address parameters Load or execute a firmware update Backup or restore of an application List mode To change to the List mode from the Wizard Mode click to the link "Switch to list mode". In the List mode every TM module available in you network is listed. By selecting the corresponding TM in the list, there are the same functions available by context menu (right click), which were listed above. Additionally the Web page integrated to the Teleservice module may directly be accessed by "Open in browser" HB39E - TM - RE_900-2E651 - Rev. 10/16 3-7

36 Chapter 4 Deployment TM Basics IP address and subnet Industrial Ethernet exclusively supports IPv4. At IPv4 the IP address is a 32Bit address that must be unique within the network and consists of 4 numbers that are separated by a dot. Every IP address is a combination of a Net-ID and a Host-ID and its structure is as follows: xxx.xxx.xxx.xxx Range: to The network administrator also defines IP addresses. Net-ID Host-ID The Network-ID identifies a network res. a network controller that administrates the network. The Host-ID marks the network connections of a participant (host) to this network. Subnet mask The Host-ID can be further divided into a Subnet-ID and a new Host-ID by using a bit for bit AND assignment with the Subnet mask. The area of the original Host-ID that is overwritten by 1 of the Subnet mask becomes the Subnet-ID, the rest is the new Host-ID. Subnet mask binary all "1" binary all "0" IPv4 address Net-ID Host-ID Subnet mask and IPv4 address Net-ID Subnet-ID new Host-ID Subnet A TCP-based communication via point-to-point, hub or switch connection is only possible between stations with identical Network-ID and Subnet-ID! Different area must be connected with a router. The subnet mask allows you to sort the resources following your needs. This means e.g. that every department gets an own subnet and thus does not interfere another department. Address at first start-up At the first start-up the TM has the following IP address: IP address: Subnet mask: Attention! For every Teleservice module is delivered with the IP address you must not connect more than one new Teleservice module at one time. First commissioning: Connect the new TM with the network, assign TCP/IP address parameters. Now you may connect the next new TM and so on HB39E - TM - RE_900-2E651 - Rev. 10/16

37 Chapter 4 Deployment TM Address classes For IPv4 addresses there are five address formats (class A to class E) that are all of a length of 4byte = 32bit. Class A 0 Network-ID (1+7bit) Host-ID (24bit) Class B 10 Network-ID (2+14bit) Host-ID (16bit) Class C 110 Network-ID (3+21bit) Host-ID (8bit) Class D 1110 Multicast group Class E Reserved The classes A, B and C are used for individual addresses, class D for multicast addresses and class E is reserved for special purposes. The address formats of the 3 classes A, B, C are only differing in the length of Network-ID and Host-ID. Private IP networks To build up private IP-Networks within the Internet, RFC1597/1918 reserves the following address areas: Network Start IP End IP Standard subnet mask class A B C (The Host-ID is underlined.) These addresses can be used as net-id by several organizations without causing conflicts, for these IP addresses are neither assigned in the Internet nor are routed in the Internet. Reserved Host-IDs Some Host-IDs are reserved for special purposes. Host-ID = 0 Identifier of this network, reserved! Host-ID = maximum (binary complete 1) Broadcast address of this network Note! Never choose an IP address with Host-ID=0 or Host-ID=maximum! (e.g. for class B with subnet mask = , the " " is reserved and the " " is occupied as local broadcast address for this network.) HB39E - TM - RE_900-2E651 - Rev. 10/16 3-9

38 Chapter 4 Deployment TM Changing the IP address For the access to the Teleservice module valid IP address parameters are necessary. The IP addresses are assigned by the network administrator. Per default the Teleservice module is delivered with the IP address You may switch to the IP address parameter wizard with "Set IP address". By clicking to [Browse...] each TM of the network is listed. Choose the TM, which corresponds to the serial number. Confirm your input and click to [Continue >]. The dialog window to enter IP address data is opened. Enter the new IP address parameters. By clicking to [Continue >] the new IP address parameters are transferred to the TM. The TM module is started new. After a certain waiting period and during successful transmissions this is reported. [Finish >] closes the dialog. Symbolic name instead of IP address With each new dial-in of the Teleservice module, this is assigned automatically with a new IP address. This is called dynamic address allocation. Usually the TM sends an containing the current valid IP address. By this IP address the TM may be accessed. With the service of a DNS service provider like e.g. there is the possibility to directly access the TM by a name instead by the IP address. Here usually a free user account is to be established. The corresponding DNS service provider may be selected on the Web page of the TM at "Networking config" with the page "Publish IP address". Here the user data may be entered. During communication the dynamic IP address is submitted to the service provider and there transformed to the symbolic name HB39E - TM - RE_900-2E651 - Rev. 10/16

39 Chapter 4 Deployment TM Update firmware A firmware update happens in 2 steps: Update ebuddy Update firmware Update ebuddy With "Update ebuddy" the firmware files may directly be stored at you PC. This is necessary to update the firmware of you TM. As source the Internet or a local directory may be selected. With [Continue >] the available firmware language versions are listed. Select the corresponding version and download it with [Continue >] to your PC. Update firmware With "Update firmware" a dialog window is opened to request the login data. By selecting the corresponding TM and by entering the login data, the firmware versions at your PC and at the Teleservice module are listed. Choose the concerning firmware version at your PC. The update procedure is started by [Continue >]. Attention! When installing a new firmware you have to be extremely careful. Under certain circumstances you may destroy the TM, for example if the voltage supply is interrupted during transfer or if the firmware file is defective. In this case, please call the VIPA-Hotline! The proceeding of the update is shown as a proceeding bar. Wait here until the bar is at 100%. A successful update is reported by a status report. HB39E - TM - RE_900-2E651 - Rev. 10/

40 Chapter 4 Deployment TM Backup / restore application With this function the configuration of a Teleservice module may be stored and uploaded to the TM module. Each modification on the configuration of the TM should be stored. Backup Open the dialog window with clicking to "Backup/restore application". Select "Backup". Even if you want to forward the backup to the VIPA support the files relevant to the support should also be saved. Here activate the option "Include support files". Click to [Continue >]. Select the corresponding Teleservice module, enter your login data and click to [Continue >]. Navigate to the concerning directory and enter a file name. With [Continue >] the backup is stored with the file name in the concerning directory. The proceeding of the write procedure is shown as a proceeding bar. Wait here until the bar is at 100%. As soon as the backup is finished, you get a feedback. Restore Open the dialog window with clicking to "Backup/restore application". Select "Restore" and click to [Continue >]. Select the corresponding TM, enter your login data and click to [Continue >]. Navigate to the concerning directory and enter a file name of the backup. With [Continue >] the data are transferred to the TM. The proceeding of the write procedure is shown as a proceeding bar. Wait here until the bar is at 100%. As soon as the restore is finished, you get a feedback HB39E - TM - RE_900-2E651 - Rev. 10/16

41 Chapter 4 Deployment TM TM - Reset Overview At the front-side of the Teleservice module there is a Reset button. This may be located below the LEDs and may be operated by a pointed object. With the Reset (user reset) extra created Web pages and Tag configurations are erased. Here the communication settings are still remaining. For a complete reset please contact the VIPA support. Caution! An unauthorized complete reset, which possibly was not carefully executed, leads automatically to the expiring of the warranty! Then the device must be sent back to VIPA for reprogramming. User-Reset There is the following proceeding for the user reset: Switch-off the Teleservice module. Press the Reset button. Switch-on the Teleservice module and leave the reset button pressed as long as the "USER"-LED is blinking red. Release the Reset button now. Now the Teleservice module executes a restart. Wait until the "USER"-LED blinks green. HB39E - TM - RE_900-2E651 - Rev. 10/

42 Chapter 4 Deployment TM TM - Web page Access to the Web page Start the VIPA configuration tool "ebuddy". Switch to the list view with "Switch to list mode". Here every TM available in your network is listed. Click to the concerning TM and select in the context menu "Open in browser". Your Web browser is opened with the request of User name and Password. Per default the TM is delivered with the following user data: User name: Password: adm adm After entering User name and Password the web page of the corresponding Teleservice module is opened HB39E - TM - RE_900-2E651 - Rev. 10/16

43 Chapter 4 Deployment TM Structure Main menu View I/O Alarm Summary Alarm History Diagnostic File transfer Configuration Tag Setup System Setup IO Server Config Script Setup User Setup Pages List The functionalities of your Teleservice module are separated to the areas Main menu and Configuration with the following structure. Each information of the Teleservice module may be accessed by the Main menu. The Information are separated to the following pages: Shows a list of the configured Tags. Here PLC value may be preset and evaluated. At this page the current alarms are listed. Here the alarms may be acknowledged. Here each alarm and history arte listed. This page serves several possibilities for diagnostics of the TM module by means of sub pages. Here each information may be downloaded from the Teleservice module as lists. Every setting of the Teleservice module may be established by this page. Here the main functionalities are separated to the following pages: Here Tags may be configured, which were listed at "View I/O" and may be controlled there. Via this page the basic parameters of the Teleservice module may be accessed. Depending on the functionality these are assigned to the pages General (general settings, net services and diagnosis), Communication (Interfaces and network) and Storage (administration storage memory). There are pre-defined servers for several communication protocols and systems inside the Teleservice module. By selecting the corresponding server this may be configured. To expand the functionalities, scripts may be programmed by means of a BASIC language. Scripts may be transferred and maintained by this page. Here users may be applied and administrated. To increase the structure, Tags may be assigned to several pages. The administration of these pages happens by this page. HB39E - TM - RE_900-2E651 - Rev. 10/

44 Chapter 4 Deployment TM TM - PLC linking Preconditions For the further approach there is condition your Teleservice module has valid IP address parameters and the Web page of the TM may be accessed. Connect VIPA PLC via MPI To get access to the VIPA PLC, the VIPA CPU is to be connected to the MPI jack of the Teleservice module via a suited MPI cable. If there is an Ethernet CP within your PLC, for TM access you may connect it to Ethernet instead to MPI. Switch-on the power supply of the CPU and switch the CPU to RUN. Configure VIPA PLC in TM Open the concerning Web page of the Teleservice module. Now you are requested for access parameters. Per default the TM has the following access parameters: Access parameters User name: adm Password: adm After entering of User name and Password the Web page of the Teleservice module is opened. Open with Configuration > IO Server Config the page to preset I/O server HB39E - TM - RE_900-2E651 - Rev. 10/16

45 Chapter 4 Deployment TM I/O server configuration For the VIPA PLC select as I/O server "S73&400". The following dialog window is opened: At "Gateway Configuration" and "MPI/Profibus Setup" the values are preset, which are to be used per default. - Destination node (Address of the destination node) - Protocol type (standard: MPI) - Baud rate (standard: ) - Reply Timeout (standard: 3000ms) - MPI/Profibus Address (Address of the TM module, standard: 0) - Highest MPI/Profibus Address (standard: 31) At Topic... access paths to your PLC may be defined, assigned to a corresponding Topic character and activated. By presetting the key words MPI, PROFIBUS respectively ISOTCP and adding an address, a corresponding access path may be defined. Access via Profibus: PROFIBUS, # (with # corresponds to the Profibus address of your connected PLC) Example: PROFIBUS, 5 Access via MPI: MPI, # (with # corresponds to the MPI address of your PLC) Example: MPI, 2 Access via IP address: ISOTCP,IP address,00.02 Enter each without spaces and always add to the IP address ",00.02". Example: ISOTCP, ,00.02 Enter at Poll Rate the standard value 2000ms and click at [Update config]. HB39E - TM - RE_900-2E651 - Rev. 10/

46 Chapter 4 Deployment TM Test PLC connection To test the MPI connection a Tag is to be created. In a Tag memory areas of you PLC are defined. These storage areas may R/W accessed by the Tag. To establish a Tag open at the Web page the page "Tag setup" and click at "Create new Tag...". Enter the following parameters: Tag name: Test Server name: S73&400 Topic name: A Address: MW0 Type: Boolean Otherwise leave the standard setting and click at [Add/Update...]. Access via View I/O Switch with Main menu > View I/O to the Tag list. Enter a new value for the Tag "Test" and click at [Update]. Now this value is set and may be transferred to the CPU with clicking to [Update] in the headline. If the new value is accepted by the CPU, so the communication between the TM and the CPU is secured HB39E - TM - RE_900-2E651 - Rev. 10/16

47 Chapter 4 Deployment TM TM - Project integration - PG/PC interface via NetPro Precondition For the further approach it is precondition that you have access to the Web page of the Teleservice module and your CPU is connected to the Teleservice module via MPI and is accordingly configured (see "TM - PLC linking"). For the project engineering, a thorough knowledge of the Siemens SIMATIC manager the hardware configurator and NetPro is required. IP address and subnet mask of your PC are known. Teleservice With the teleservice the Teleservice module works as gateway. As gateway via the served communication connections you have access to the VIPA PLC, which is connected via MPI to the TM. So that the TM can work as gateway, you have to integrate this to your hardware configuration. Load TM-E.cfg station file For the deployment of the Teleservice module in the Siemens SIMATIC manager, the installation of the station file TM-E.cfg is necessary. This file may be found in the download area at Download this file to your PC. Later this file is to be imported to the PG/PC interface. De-activate the automatic IP address assignment Since in the Teleservice module predefined IP address data for the PPP server are used, in your project you have to de-activate the automatic address assignment. Start the Siemens SIMATIC manager with your project. Your project should contain your CPU, which is connected via MPI to the MPI bus. Open via Options > Set PG/PC interface the properties dialog. Select the interface parameter assignment "TCP/IP(Auto)...", which corresponds to your network card and click to [Properties]. Select the Register "IE-PG Access" and activate the parameter "Do not assign IP address automatically". Confirm your setting with [OK]. HB39E - TM - RE_900-2E651 - Rev. 10/

48 Chapter 4 Deployment TM Integrate the TM to the Siemens SIMATIC manager The integration of the Teleservice module to your project happens as PG/PC interface. After the configuration this may be defined as access path for the PLC functions. The configuration happens with the following approach: Start the software NetPro, by clicking to. For example you see the following structure: Add PG/PC station Add the station "PG/PC" from Network, by double-clicking to the station "PG/PC" HB39E - TM - RE_900-2E651 - Rev. 10/16

49 Chapter 4 Deployment TM Properties PG/PC station Open the properties of the PG/PC station. Access the register "Interfaces" and click to [New...]. Select the type "Industrial Ethernet" and click to [OK]. De-activate "Set MAC address..." Enter at "IP address" and "Subnet mask" the IP address parameters of you PC determined before. To establish a new subnet click at [New...]. Confirm the properties with [OK]. Select if not happened the new established subnet and click at [OK]. Now you are back in the properties dialog. Call the register "Assignment". Highlight at "Configured Interfaces" your Ethernet interface and select at "Interface parameter assignments in the PG/PC" the parameter, which starts with "TCP/IP(Auto) ->..." and corresponds to your network card. Click at [Assign]. Ignore the warn messages and close the "properties" dialog with [OK]. HB39E - TM - RE_900-2E651 - Rev. 10/

50 Chapter 4 Deployment TM Now your graphical net view should show the following structure: Import the TM via station file To import the Teleservice module to your project the first downloaded station file is necessary. Start in NetPro the import via Edit > Import. Activate the parameter "Export file of a station". Enter path and name of the station file TM-E.cfg and click to [OK]. Possibly appearing warnings may be ignored by [Close]. Now your graphical net view should show the following structure: Open the properties dialog of the communication component "IE General" of the station "TM-E". Click in the area "Interface" at [Properties...]. A dialog window for IP address data settings is opened HB39E - TM - RE_900-2E651 - Rev. 10/16

51 Chapter 4 Deployment TM Define access via IP address Depending on the access modes to your Teleservice module, there are the following possibilities to preset IP address parameters: Access via Ethernet Enter here IP address and subnet mask of your TM. The IP address parameters must correspond to the IP address parameters, which were preset with the software tool "ebuddy". Access via PPP connection If you want to access your TM via dial connection (PPP connection), the following preset IP address parameters are to be used: IP address: Subnet mask: Set the MPI address Open the properties dialog of the communication component "MPI/DP" of "TM-E". Enter the MPI address. This must correspond to the MPI address preset by the software tool "ebuddy". NetPro should now show the following structure. Transfer the project to the CPU Click in the graphical net view at the CPU and transfer your project with Download > Selected stations. Now your CPU may be accessed via this connection from the Siemens SIMATIC manager. HB39E - TM - RE_900-2E651 - Rev. 10/

52 Chapter 4 Deployment TM TM - Project integration - PG/PC interface via evcom Overview As another version here the project integration is to be shown by means of a virtual MPI interface. To do this on the PC side the driver "evcom" from VIPA is to be installed. Contrary to "Project integration via NetPro" no adjustment is necessary on the PLC side. This version is easy to use but slower than "Project integration via NetPro". With this functionality HMI devices may be accessed, which were configured via MPI. With the teleservice the Teleservice module works as gateway. As gateway via the served communication connections you have access to the PLC, which is connected via MPI to the TM. Precondition For the further approach it is precondition that you have access to the Web page of the Teleservice module and your CPU respectively your HMI device is connected to the Teleservice module via MPI and is accordingly configured (see "TM - PLC linking"). Installation The driver file "evcom" may be found in the download area For installation start evcomsetup.exe and follow the instructions. Establish virtual interface Start evcom. In the Dialog window click at [Add Port] Select a free COM port of your PC and choose "MPI ISO TCP" for MPI communication. Confirm your settings with [OK]. Enter at Gateway address a valid IP address (see below). Do not change the Gateway port "102". Confirm you settings and click at [Enable Port]. The virtual MPI interface is now activated. This is shown by the symbol in the list HB39E - TM - RE_900-2E651 - Rev. 10/16

53 Chapter 4 Deployment TM Define access via IP address Depending on the access mode to your Teleservice module, there are the following possibilities to preset the IP address: Access via Ethernet The IP address must be the same as the IP address, which was preset by the software tool "ebuddy". Access via PPP connection If you want to access your TM via dial connection (PPP connection), the IP address is to be used. Settings in the Siemens SIMATIC Manager Load your project in the SIMATIC manager from Siemens. Choose in the menu Options > Set PG/PC interface. Select in the according list the "PC Adapter (MPI)"; if appropriate you have to add it first, the click at [Properties]. Switch to the register MPI. Set the transfer parameters of your MPI net and type in an unused address. Switch to the register Local connection. Select the COM port, which you have configured at evcom and set the transfer rate to 38400baud. Confirm you settings with [OK]. Now your CPU may be accessed with the TM via MPI by means of the PLC functions. HB39E - TM - RE_900-2E651 - Rev. 10/

54 Chapter 4 Deployment TM Installation of the SIM card Caution! Please regard the SIM card may only be plugged if you have configured it at the TM Web page, before. Else your SIM card may be blocked! Preconditions For the further approach it is precondition that you have access to the Web page of the TM and you have a valid GSM SIM card with PIN. Configuration at the Web page Open the Web page of the Teleservice module. Navigate via Configuration > System setup to the page "Communication". Open at the navigation tree Interfaces the page "Modem". At "GSM PIN" type in the pin number, which is delivered with your SIM card. Leave every values at default setting and click at [Update]. Installing the SIM card The slot for the SIM card is located at the rear-side of the module. The SIM card should be installed before the assembly. The installation happens with the following approach: Switch off the power supply of the Teleservice module. Insert the SIM card as shown to the SIM card slot. Please regard here the correct positioning! For taking the SIM cart push the eject button with a pointed object. The eject button may be found above the card slot HB39E - TM - RE_900-2E651 - Rev. 10/16

55 Chapter 4 Deployment TM Commissioning with SIM card Connect if not just happened a suited antenna. The Teleservice module has a an antenna jack. Here a GSM dual band antenna may be connected. The TM is delivered without any antenna. You may get a suited antenna from VIPA. You find the order numbers in this manual under "Properties". Switch-on again the power supply of the TM. With a cold restart it may last up to 2 minutes until the GSM modem is been rebooted and initialized. Open the Web page of the Teleservice module. Navigate via Configuration > System setup to the page "Communication". Open in the navigation tree Interfaces the page "Modem". If you have made everything correctly and your GSM modem is connected to a mobile network, the following parameters are listed: Modem detected This parameter shows you the type of the internal modem. Here the text "internal Multiband GSM" should be shown. Signal level Here the signal level is shown. This value is determined once a minute. For a communication connection this value should be higher than 17. A value of 25 corresponds to a good connection. If a value is higher than 30 this correspond to an excellent connection. A signal level of 0 indicates a non existing mobile network. Network "Home Network" is shown if the SIM card is operated in the country of which the SIM card is from. If the Teleservice module is operated in an other country, "Roaming" is shown. Otherwise the following error messages may be displayed with his parameter: - "SIM card error!" if SIM card is missing - "PIN code error!" if PIN is faulty - "in operation..." the modem tries to connect to a mobile network. Operator Here the name of your mobile network provider is listed. HB39E - TM - RE_900-2E651 - Rev. 10/

56 Chapter 4 Deployment TM Deployment of Tags Precondition For the further approach it is precondition that you have access to the Web page of the Teleservice module, your PLC may be reached via the TM and the corresponding Topics are configured. The access paths to your PLC are defined by Topics. More about the configuration of Topics may be found at "TM - PLC linking". What is a Tag? A Tag is a digital respectively analog value, which is assigned to a data source. For example the data source could be a flag word of your PLC. To a Tag you have reading and writing access (configurable). So the directly assigned data source may be accessed by the Tag. By presetting of limit values for a Tag, the TM has the possibility for limit monitoring and appropriate alerting via SMS respectively . Establishing a Tag Open the Web page of the TM to establish a Tag. Navigate via Configuration > Tag setup to the page "Create New Tag...". Here the following parameters may be entered: Identification Tag name: Page: Tag description: Name with which the Tag is listed. The Tag name may maximally consist of 64 characters and must not include the following characters: space, $ " Let the value at "Standard" Give a comment to the Tag I/O server setup Server name: Topic name: Address: For VIPA PLCs select "S73&400" Devices within an I/O server are grouped by Topic name. Enter A, if you have defined your MPI interface as Topic A, as described at "TM-E - PLC linking". Enter a value from your PLC, which is to be assigned to the Topic (see the following table). Type: Here define as Type boolean or analog depending on the parameter Address. Alarm setup If you wish an alerting, you may enter limit values here for alert messages HB39E - TM - RE_900-2E651 - Rev. 10/16

57 Chapter 4 Deployment TM Name conventions for Address The following symbolic names may be used on deployment together with a VIPA PLC by selecting "S73&400" server: Symbol Symbol Memory type Modificator Address DBx Data block with No. x B, C, W, S, D, L, F Byte offset M Internal memory (flag) B, C, W, S, D, L, F Byte offset C Counter W, S Counter No. T Timer W, S Timer No. I Process inputs B, C, W, S, D, L, F Byte offset Q Process outputs B, C, W, S, D, L, F Byte offset PI Peripheral inputs B, C, W, S, D, L, F Byte offset PQ Peripheral outputs B, C, W, S, D, L, F Byte offset Modificator Modificator Type Range of values B Byte C Byte with sign W Word (default) S Word with sign D DWord L DWord with sign F Float +/- 3.4E38 Bit access via # With each memory type there is the possibility to access a bit. Here add a # and the bit no. to the Address name. For the bit no. the values may be used. Note! If you do not enter a Modificator automatically the type "Word" is used. With data blocks a Modificator is always to be entered. Example Address Description MW4 Flag word 4 CS1 Counter 1, read as word with sign TS7 Timer 7, read as word with sign DB2L5 DWord at address 5 (in bytes) in data block 2 IB3 Byte at address 3 (in bytes) in the input area I5#2 Input I5.2 Q10#6 Output Q10.6 HB39E - TM - RE_900-2E651 - Rev. 10/

58 Chapter 4 Deployment TM Examples For the further approach it is precondition that you have access to the Web page of the Teleservice module, your PLC may be reached via the TM and the corresponding Topics are configured. Accessing data in the PLC Open the Web page of the Teleservice module. Navigate via Configuration > Tag setup to the page "Create new Tag...". Enter the following parameters: Tag name: Test Server name: S73&400 Topic name: A Address: MW0 Type: Boolean Otherwise leave the standard setting and click at [Add/Update...]. Access via View I/O Switch with Main menu > View I/O to the Tag list. Enter a new value for the Tag "Test" and click at [Update]. Now this value is set and may be transferred to the CPU with clicking to [Update] in the headline. If the new value is accepted by the CPU, so the communication between the TM and the CPU is secured. Accessing the I/Os of the TM Open the Web page of the Teleservice module. Navigate via Configuration > Tag setup to the page "Create new Tag...". Enter the following parameters: Tag Name: TM_Input res. TM_Output Server Name: TM TM Topic Name: remains free remains free Adresse: DI1 DO1 Typ: Digital Digital Otherwise leave the standard setting and click at [Add/Update...]. Access via View I/O Here also the input may be read respectively the output may be written by means of the Tag list HB39E - TM - RE_900-2E651 - Rev. 10/16

59 PWR MPI DI VIPA 900-2E631 USER MODEM DO Chapter 4 Deployment TM Teleservice via telephone with MPI gateway Overview With the teleservice via telephone with MPI gateway, a connection via telephone (PPP connection) is directly established from your PC to the TM. Here the CPU is linked to the Teleservice module by MPI. To be able to react to the calling, to authenticate the user and to assign the IP address, the TM is to be configured as PPP server. The following picture shows the network topology on an example: PC PC TM SPS PPP connection LAN MPI WAN/PPP ETHERNET LINE MPI: 0 MPI: 2 In the configuration above there are 2 various networks: is the network of your PC is the temporary network, which is to be used for the PPP connection. This network is only active during PPP connection. Precondition For the further proceeding it is precondition you have access to the Web page of the Teleservice module and your CPU is connected to the TM module via MPI and accordingly configured. Further it is precondition that a SIM card installed and your TM module is connected to the mobile network. HB39E - TM - RE_900-2E651 - Rev. 10/

60 Chapter 4 Deployment TM Configuration of the direct telephone connection To access the Teleservice module via PPP connection the server for incoming PPP connections is to be configured. Here open the Web page of the Teleservice module. Navigate to the "Communication" page via Configuration > System setup. Open the page "Incoming" in the navigation tree Network Connection > Modem. Activate the option "Server enabled". Here enter the following parameters: - "TM-E PPP server IP address": "PPP client IP address": Accept the remaining default settings and click at [Update]. Configure your PC modem so that it may establish a connection to the TM module. Here establish a DFÜ connection. More about this may be found in the manual of your PC operating system. Here please regard that User name and Password are identical to the access data in you Teleservice module. Test the telephone connection Call your Teleservice module via the PC modem. Open as soon as the TM reacts a DOS command window and send a ping to the IP address You should now get a response. Else check your settings HB39E - TM - RE_900-2E651 - Rev. 10/16

61 Chapter 4 Deployment TM Configure routing in PLC project Information how to integrate your TM to your PLC may be found at "TM - Project integration - PG/PC interface". If you have just integrated your TM into your PLC project, at the TM station of NetPro the routing is accordingly be adapted. Open NetPro with your project. Open the properties dialog of the communication component "IE General" of the station "TM-E". Click at "Interface" at [Properties]. A dialog window for presetting the IP address data is opened. Access defined by IP address For the access via PPP dial connection the following predefined IP address data are to be used: IP address: Subnet mask: Set MPI address Open the properties dialog of the communication component "MPI/DP" of "TM-E". Enter the MPI address. This must be the same as the MPI address configured with the software tool "ebuddy". Please regard that your CPU is connected via MPI and the MPI address is accordingly assigned. VIPA CPUs are delivered with MPI address 2. HB39E - TM - RE_900-2E651 - Rev. 10/

62 Chapter 4 Deployment TM NetPro should now show the following structure. Transfer the project to the CPU Click in the graphical net view at the CPU and transfer your project with Download > Selected stations HB39E - TM - RE_900-2E651 - Rev. 10/16

63 PWR MPI DI VIPA 900-2E631 USER MODEM DO Chapter 4 Deployment TM Teleservice via Callback function Overview With Callback there is the possibility to call the Teleservice module with a defined number of ring signals to initiate the callback mode. Now the module accesses the Internet and sends an , which contains in its text a dynamic PPP IP address. This address may be accessed as long as the TM module is online. So you may safe money for connection, if e.g. the plant to be observed is abroad. The configuration of the Callback mode happens on the Web page of the TM module with the following approach: Configuration of the direct telephone connection Configuration of the dial-up server Configuration of the mail server Activation of the Callback Precondition For the further proceeding it is precondition you have access to the Web page of the TM and your CPU is connected to the TM module and accordingly configured. Further it is precondition that a SIM card installed and your TM is connected to the mobile network. Configuration of the direct telephone connection If you have just established the Teleservice via telephone, please continue with the configuration of the dial-up server. With the Teleservice via telephone a connection via telephone (PPP connection) is directly established from your PC to the TM. To be able to react to the calling, to authenticate the user and to assign the IP address, the TM is to be configured as PPP server. The following picture shows the network topology on an example: PC PC TM SPS PPP connection LAN MPI WAN/PPP ETHERNET LINE In the configuration above there are 2 various networks: is the network of your PC is the temporary network, which is to be used for the PPP connection. This network is only active during PPP connection. HB39E - TM - RE_900-2E651 - Rev. 10/

64 Chapter 4 Deployment TM Configuration To access the TM via PPP connection the server for incoming PPP connections is to be configured. Here open the Web page of the Teleservice module. Navigate to the "Communication" page via Configuration > System setup. Open the page "Incoming" in the navigation tree Network Connection > Modem. Activate the option "Server enabled". Here enter the following parameters: - "TM-E PPP server IP address": "PPP client IP address": Accept the remaining default settings and click at [Update]. Configure your PC modem so that it may establish a connection to the TM. Here establish a DFÜ connection. More about this may be found in the manual of your PC operating system. Here please regard that User name and Password are identical to the access data in you TM. The default access parameters are: User name: Password: adm adm Test the telephone connection Call your Teleservice module via the PC modem. Open as soon as the TM reacts a DOS command window and send a ping to the IP address You should now get a response. Else check your settings HB39E - TM - RE_900-2E651 - Rev. 10/16

65 Chapter 4 Deployment TM Configuration of the dial-up server Activate the dial-up server for the dial-up to the Internet. Here open the Web page of the TM. Navigate via Configuration > System setup to the page "Communication". Open at the navigation tree Network connection > Modem > Outgoing the page "Global". Activate the option "PPP outgoing connection parameters". Leave every value at default setting and click at [Update]. Click at "Server1". For the dial-up via modem enter Server phone number, User name and Password and click at [Update]. HB39E - TM - RE_900-2E651 - Rev. 10/

66 Chapter 4 Deployment TM Configuration of the mail server To enter the SMTP server open the page "General" at "System setup". Navigate at the navigation tree to Net Services > SMTP (mails). Here enter the following parameters: - SMTP server address (may be an IP address or a domain) - SMTP server port (default: 25) - address (valid address) - User name and Password may only be entered if secure authentication was activated in the dial-up server configuration. Activation of the Callback To activate the Callback open the page "Communication" at "System setup. Navigate in the navigation tree to Network Config > Callback. Activate the option "Callback enabled". Accept the default settings and click at [Update]. Test the Callback For a test call the telephone number of your TM. Let it ring 5 times and then disconnect. After about 30 seconds the TM attempts now to dial-up to the Internet to establish a connection to the mail server to send you an . The contains an IP address. The TM may now be accessed by this address HB39E - TM - RE_900-2E651 - Rev. 10/16

67 Chapter 4 Deployment TM Teleservice via SMS Overview With the Teleservice module with GSM modem there is the possibility to remote control your connected PLC. Here a script language with a syntax similar to BASIC is used. In this part we cannot nearly describe the programming instructions. More information about this script language may be found in the programming guide in German an English at: support.ewon.biz This Teleservice module from VIPA is constructed in the same way as the module "ewon2001". Precondition For the further proceeding it is precondition you have access to the Web page of the TM module and your CPU is connected to the TM via MPI and accordingly configured. Further it is precondition that a SIM card installed and your TM is connected to the mobile network. Creating a script To create a script open the Web page of the TM. Open with Configuration > Script setup the "Script Section". The following dialog window is opened: Here the scripts may be programmed and administrated. Per default there are the scripts "Init Section" and "Cyclic Section", which are empty. The script processing should always be stopped with [STOP (currently running)], before a script is been created respectively edited. With [RUN (currently stopped)] the scripts processing may be started again after editing. Example At the following pages you may find scripts for the following applications: Reboot TM via SMS Acknowledge alarm via SMS Request an report via SMS HB39E - TM - RE_900-2E651 - Rev. 10/

68 Chapter 4 Deployment TM Reboot TM via SMS Open the Web page of the TM. Navigate to "Script setup". To be able to use the SMS services you have to create the scripts "SMS" and "Restart". For this click at [New section]. Enter "SMS" at Script Name and click at [Update]. Click at [New section]. Enter "Restart" and click at [Update]. The new created scripts are now listed in the Script list. Select in the list the script "SMS" and click at [Edit]. In the dialog window type in the following programming code: SMS: a%=getsys Prg,"SmsRead" If(a%<>0) Then s%=s%+1 PRINT "SMS Nr: ";s% f$=getsys Prg,"smsfrom" Print"From:";f$ Print Getsys Prg,"smsdate" a$=getsys Prg,"smsmsg" Print "Message: ";a$ b$=f$+",gsm,0" If(a$="Reboot") THEN c$="received message: "+a$ d$="reboot is started in 1 min." Sendsms b$,d$ ONTIMER 1, "goto restart" Else e$="wrong instruction" Sendsms b$,e$ Endif Goto SMS Endif End 3-40 HB39E - TM - RE_900-2E651 - Rev. 10/16

VIPA Accessories. Teleservice module 900-2H611 Manual

VIPA Accessories. Teleservice module 900-2H611 Manual VIPA Accessories Teleservice module 900-2H611 Manual HB39E_TM RE_900-2H611 Rev. 10/16 April 2010 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is

More information

VIPA Accessories. Teleservice module 900-2H681 Manual

VIPA Accessories. Teleservice module 900-2H681 Manual VIPA Accessories Teleservice module 900-2H681 Manual HB39E_TM RE_900-2H681 Rev. 10/16 April 2010 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is

More information

Manual. VIPA Accessories Teleservice module TM-E 900-1E630. Order-No.: VIPA HB39E_TME Reference: RE_900-1E630 Rev. 09/11

Manual. VIPA Accessories Teleservice module TM-E 900-1E630. Order-No.: VIPA HB39E_TME Reference: RE_900-1E630 Rev. 09/11 Manual VIPA Accessories Teleservice module TM-E 900-1E630 Order-No.: VIPA HB39E_TME Reference: RE_900-1E630 Rev. 09/11 This manual is part of the documentation package with order number VIPA HB39E_TME

More information

Manual. VIPA Accessories Teleservice module TM-E 900-1E650. Order-No.: VIPA HB39E_TME Reference: RE_900-1E650 Rev. 09/11

Manual. VIPA Accessories Teleservice module TM-E 900-1E650. Order-No.: VIPA HB39E_TME Reference: RE_900-1E650 Rev. 09/11 Manual VIPA Accessories Teleservice module TM-E 900-1E650 Order-No.: VIPA HB39E_TME Reference: RE_900-1E650 Rev. 09/11 This manual is part of the documentation package with order number VIPA HB39E_TME

More information

VIPA Accessories. Teleservice module 900-2C610 Manual

VIPA Accessories. Teleservice module 900-2C610 Manual VIPA Accessories Teleservice module 900-2C610 Manual HB39E_TM RE_900-2C610 Rev. 13/28 July 2013 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not

More information

Manual. VIPA Accessories USB-MPI adapter 950-0KB31. Order No.: VIPA HB158E_PC-AG Reference: RE_950-0KB31 Rev. 08/25

Manual. VIPA Accessories USB-MPI adapter 950-0KB31. Order No.: VIPA HB158E_PC-AG Reference: RE_950-0KB31 Rev. 08/25 Manual VIPA Accessories USB-MPI adapter 950-0KB31 Order No.: VIPA HB158E_PC-AG Reference: RE_950-0KB31 Rev. 08/25 This manual is relevant for: Product Order number as of state: HW SW USB-MPI adapter VIPA

More information

VIPA System 200V. IM Manual

VIPA System 200V. IM Manual VIPA System 00V IM Manual HB97E_IM RE_6x-xA00 Rev. /44 October 0 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed or used except

More information

VIPA Accessories UZ00 Manual

VIPA Accessories UZ00 Manual VIPA Accessories 306-1UZ00 Manual HB37E_IM RE_306-1UZ00 Rev. 15/22 May 2015 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed or

More information

VIPA System 300. PS 307-1xA00 Manual. HB130 PS 307-1xA00 en PS

VIPA System 300. PS 307-1xA00 Manual. HB130 PS 307-1xA00 en PS PS 307-1xA00 Manual HB130 PS 307-1xA00 en 18-01 PS 307 www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132 744-1864 Email: info@vipa.com

More information

VIPA System SLIO. PS-CM Manual. HB300 PS-CM en PS 007-1ABxx, CM 001-1BAxx.

VIPA System SLIO. PS-CM Manual. HB300 PS-CM en PS 007-1ABxx, CM 001-1BAxx. PS-CM Manual HB300 PS-CM en 17-16 PS 007-1ABxx, CM 001-1BAxx www.vipa.com/en/service-support/manual VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: 09132-744-0 Fax: 09132-744-1864 Email: info@vipa.com

More information

VIPA System SLIO CPU 015-CEFPR00 Manual

VIPA System SLIO CPU 015-CEFPR00 Manual VIPA System SLIO CPU 015-CEFPR00 Manual HB300 CPU 015-CEFPR00 GB 16-03 SPEED7 CPU 015 VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: 09132-744-0 Fax: 09132-744-1864 Email: info@vipa.com Internet:

More information

Manual. VIPA System 300S SPEED7 - CPU 317-2AJ12. Order No.: VIPA HB140E_CPU Reference: RE_317-2AJ12 Rev. 09/11

Manual. VIPA System 300S SPEED7 - CPU 317-2AJ12. Order No.: VIPA HB140E_CPU Reference: RE_317-2AJ12 Rev. 09/11 Manual VIPA System 300S SPEED7 - CPU 317-2AJ12 Order No.: VIPA HB140E_CPU Reference: RE_317-2AJ12 Rev. 09/11 This manual is part of the documentation package with order number VIPA HB140_CPU and relevant

More information

VIPA System SLIO. IM 06x-1xA00 Manual. HB300 IM 06x-1xA00 en Interface module Line extension - IM 06x.

VIPA System SLIO. IM 06x-1xA00 Manual. HB300 IM 06x-1xA00 en Interface module Line extension - IM 06x. IM 06x-1xA00 Manual HB300 IM 06x-1xA00 en 18-10 Interface module Line extension - IM 06x www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: 09132-744-0 Fax: 09132-744-1864

More information

Manual VIPA System 500S SPEED7 - CPU

Manual VIPA System 500S SPEED7 - CPU Manual VIPA System 500S SPEED7 - CPU Order No.: VIPA HB145E_CPU Rev. 06/47 Lerrzeichen Manual VIPA System 500S SPEED7 The information contained in this manual is supplied without warranties. Information

More information

VIPA System SLIO CPU 015-CEFPR00 Manual

VIPA System SLIO CPU 015-CEFPR00 Manual VIPA System SLIO CPU 015-CEFPR00 Manual HB300 CPU 015-CEFPR00 GB 14-04 VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: 09132-744-0 Fax: 09132-744-1864 email: info@vipa.com Internet: www.vipa.com 015_000_CPU

More information

System SLIO. IM 053-1DN00 Manual. HB300 IM 053-1DN00 en Interface module DeviceNet - IM 053DN.

System SLIO. IM 053-1DN00 Manual. HB300 IM 053-1DN00 en Interface module DeviceNet - IM 053DN. IM 053-1DN00 Manual HB300 IM 053-1DN00 en 18-10 Interface module DeviceNet - IM 053DN www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49

More information

VIPA System SLIO CPU 015-CEFNR00 Manual

VIPA System SLIO CPU 015-CEFNR00 Manual VIPA System SLIO CPU 015-CEFNR00 Manual HB300 CPU 015-CEFNR00 GB 16-03 SPEED7 CPU 015N VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: 09132-744-0 Fax: 09132-744-1864 Email: info@vipa.com Internet:

More information

VIPA System 200V. CPU Manual

VIPA System 200V. CPU Manual VIPA System 200V CPU Manual HB97E_CPU RE_21x-2BT13 Rev. 14/44 October 2014 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed or

More information

VIPA System 300S. SPEED7 - CP 342-1CA70 Manual

VIPA System 300S. SPEED7 - CP 342-1CA70 Manual VIPA System 300S SPEED7 - CP 342-1CA70 Manual HB140E_CP RE_342-1CA70 Rev. 09/46 November 2009 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not

More information

VIPA System SLIO. CPU 013-CCF0R00 Manual. HB300 CPU 013-CCF0R00 en SPEED7 CPU 013C.

VIPA System SLIO. CPU 013-CCF0R00 Manual. HB300 CPU 013-CCF0R00 en SPEED7 CPU 013C. VIPA System SLIO CPU 013-CCF0R00 Manual HB300 CPU 013-CCF0R00 en 18-50 SPEED7 CPU 013C www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: 09132-744-0 Fax: 09132-744-1864

More information

VIPA System 300S. SPEED7 - CP 343-1EX71 Manual

VIPA System 300S. SPEED7 - CP 343-1EX71 Manual VIPA System 300S SPEED7 - CP 343-1EX71 Manual HB140E_CP RE_343-1EX71 Rev. 09/46 November 2009 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not

More information

VIPA SPEED7 Library. OPL_SP7-LIB SW90HS0MA V Manual. HB00 OPL_SP7-LIB SW90HS0MA V en Block library - EtherCAT Communication

VIPA SPEED7 Library. OPL_SP7-LIB SW90HS0MA V Manual. HB00 OPL_SP7-LIB SW90HS0MA V en Block library - EtherCAT Communication VIPA SPEED7 Library OPL_SP7-LIB SW90HS0MA V10.001 Manual HB00 OPL_SP7-LIB SW90HS0MA V10.001 en 18-45 Block library - EtherCAT Communication www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074

More information

VIPA System SLIO. IM 053-1MT00 Manual. HB300 IM 053-1MT00 en IM 053MT.

VIPA System SLIO. IM 053-1MT00 Manual. HB300 IM 053-1MT00 en IM 053MT. IM 053-1MT00 Manual HB300 IM 053-1MT00 en 16-47 IM 053MT www.vipa.com/en/service-support/manual VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132 744-1864 Email: info@vipa.com

More information

VIPA HMI. Text Display TD 03 Manual

VIPA HMI. Text Display TD 03 Manual VIPA HMI Text Display TD 03 Manual HB116E_TD03 Rev. 15/04 January 2015 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed or used

More information

VIPA System 300S. SPEED7 - CPU 314-2AG13 Manual

VIPA System 300S. SPEED7 - CPU 314-2AG13 Manual VIPA System 300S SPEED7 - CPU 314-2AG13 Manual HB140E_CPU RE_314-2AG13 Rev. 12/47 November 2012 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not

More information

VIPA System 100V. CPU Manual

VIPA System 100V. CPU Manual VIPA System 100V CPU Manual HB100E_CPU Rev. 15/03 January 2015 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed or used except

More information

VIPA System 200V. CPU Manual

VIPA System 200V. CPU Manual VIPA System 00V CPU Manual HB97E_CPU RE_1x-BE03 Rev 14/44 October 014 Copyright VIPA GmbH All Rights Reserved This document contains proprietary information of VIPA and is not to be disclosed or used except

More information

VIPA System 300S. SPEED7 - CPU SC 314-6CG13 Manual

VIPA System 300S. SPEED7 - CPU SC 314-6CG13 Manual VIPA System 300S SPEED7 - CPU SC 314-6CG13 Manual HB140E_CPU-SC RE_314-6CG13 Rev 11/27 July 2011 Copyright VIPA GmbH All Rights Reserved This document contains proprietary information of VIPA and is not

More information

VIPA System 300S. CP 342-1DA70 Manual. HB140 CP 342-1DA70 en SPEED7 CP 342S-DP.

VIPA System 300S. CP 342-1DA70 Manual. HB140 CP 342-1DA70 en SPEED7 CP 342S-DP. VIPA System 300S CP 342-1DA70 Manual HB140 CP 342-1DA70 en 17-22 SPEED7 CP 342S-DP www.vipa.com/en/service-support/manual VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132

More information

VIPA System 300S CP 342-1DA70 Manual

VIPA System 300S CP 342-1DA70 Manual CP 342-1DA70 Manual HB140 CP 342-1DA70 GB 16-33 SPEED7 CP 342S-DP VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132 744-1864 Email: info@vipa.com Internet: www.vipa.com 342-1DA70_000_CP342S-DP,1,GB

More information

VIPA System SLIO. IM 053-1EC01 Manual. HB300 IM 053-1EC01 en Interface module EtherCAT - IM 053EC.

VIPA System SLIO. IM 053-1EC01 Manual. HB300 IM 053-1EC01 en Interface module EtherCAT - IM 053EC. VIPA System SLIO IM 053-1EC01 Manual HB300 IM 053-1EC01 en 18-45 Interface module EtherCAT - IM 053EC www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132

More information

MANUAL ELCO FS200 IM FS2-GW-PN00

MANUAL ELCO FS200 IM FS2-GW-PN00 MANUAL ELCO FS200 IM FS2-GW-PN00 Manual ELCO FS200 Contents Contents About this manual... 1 Safety information... 2 Chapter 1 Basics and Assembly... 1-1 Safety Information for Users... 1-2 System conception...

More information

VIPA System 200V. CPU Manual

VIPA System 200V. CPU Manual VIPA System 00V CPU Manual HB97E_CPU RE_1x-BP03 Rev. 14/44 October 014 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed or used

More information

VIPA System SLIO. IM 053-1PN00 Manual. HB300 IM 053-1PN00 en Interface module PROFINET - IM 053PN.

VIPA System SLIO. IM 053-1PN00 Manual. HB300 IM 053-1PN00 en Interface module PROFINET - IM 053PN. VIPA System SLIO IM 053-1PN00 Manual HB300 IM 053-1PN00 en 17-28 Interface module PROFINET - IM 053PN www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132

More information

Manual. VIPA System 300V CP 341-1AH01. Order No.: VIPA HB130E_CP Reference: RE_341-1AH01 Rev. 08/43

Manual. VIPA System 300V CP 341-1AH01. Order No.: VIPA HB130E_CP Reference: RE_341-1AH01 Rev. 08/43 Manual VIPA System 300V CP 341-1AH01 Order No.: VIPA HB130E_CP Reference: RE_341-1AH01 Rev. 08/43 This manual is part of the documentation package with order number VIPA HB130E_CP and relevant for: Product

More information

VIPA Networking Solutions

VIPA Networking Solutions VIPA Networking Solutions TM 900-2C5x0 Manual TM-C Router www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132 744-1864 Email: info@vipa.com

More information

VIPA System 200V CPU 215-2BT16 Manual

VIPA System 200V CPU 215-2BT16 Manual VIPA System 200V CPU 215-2BT16 Manual HB97 CPU 215-2BT16 GB 16-17 CPU 215NET VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132 744-1864 Email: info@vipa.com Internet: www.vipa.com

More information

ewon Flexy PSTN Extension Card FLA 3501

ewon Flexy PSTN Extension Card FLA 3501 Installation Guide IG 021 / Rev. 1.2 FLA 3501 This installation guide explains how to install the FLA 3501. support.ewon.biz Table of Contents 1. Product Summary... 3 2. Safety, Environmental & Regulatory

More information

VIPA System 200V. PS-CM Manual

VIPA System 200V. PS-CM Manual VIPA System 00V PS-CM Manual HB97E_PS-CM Rev. /7 November 0 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed or used except in

More information

VIPA HMI. Commander Compact CC 03 Manual

VIPA HMI. Commander Compact CC 03 Manual VIPA HMI Commander Compact CC 03 Manual HB116E_CC03 Rev. 15/04 January 2015 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed or

More information

Manual. VIPA System 300V CP 341-1CH01. Order No.: VIPA HB130E_CP Reference: RE_341-1CH01 Rev. 08/43

Manual. VIPA System 300V CP 341-1CH01. Order No.: VIPA HB130E_CP Reference: RE_341-1CH01 Rev. 08/43 Manual VIPA System 300V CP 341-1CH01 Order No.: VIPA HB130E_CP Reference: RE_341-1CH01 Rev. 08/43 This manual is part of the documentation package with order number VIPA HB130E_CP and relevant for: Product

More information

ewon Flexy PSTN Extension Card FLA P3501 Installation Guide

ewon Flexy PSTN Extension Card FLA P3501 Installation Guide ewon Installation Guide IG 021 / Rev 1.0 ewon Flexy PSTN Extension Card FLA P3501 Contents Installation Guide This installation guide explains how to install the ewon Flexy PSTN Extension Card FLA 3501.

More information

CPCI-PS24 24V-Power Supply

CPCI-PS24 24V-Power Supply 24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72

More information

VIPA System 300S CPU CPU 315-2AG12 Manual

VIPA System 300S CPU CPU 315-2AG12 Manual CPU 315-2AG12 Manual HB140 CPU 315-2AG12 GB 14-40 VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132 744-1864 email: info@vipa.com Internet: www.vipa.com 315-2AG12_000_CPU

More information

VIPA System 300S CPU 317-4PN12 Manual

VIPA System 300S CPU 317-4PN12 Manual CPU 317-4PN12 Manual HB140 CPU 317-4PN12 GB 14-29 VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: 09132-744-0 Fax: 09132-744-1864 email: info@vipa.com Internet: www.vipa.com 317-4PN12_000_CPU 317SN/PN,1,GB

More information

VIPA System 300S + CPU 314-6CF23 Manual. HB140 CPU 314-6CF23 en SPEED7 CPU 314ST.

VIPA System 300S + CPU 314-6CF23 Manual. HB140 CPU 314-6CF23 en SPEED7 CPU 314ST. VIPA System 300S + CPU 314-6CF23 Manual SPEED7 CPU 314ST www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132 744-1864 Email: info@vipa.com

More information

VIPA System 300S CPU CPU 314-2BG03 Manual

VIPA System 300S CPU CPU 314-2BG03 Manual CPU 314-2BG03 Manual HB140 CPU 314-2BG03 GB 14-40 VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132 744-1864 email: info@vipa.com Internet: www.vipa.com 314-2BG03_000_CPU

More information

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Operating Manual. English. Digital-Analog Converter DACON8-UMB. English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before

More information

VIPA System 300S. CP 341-1CH01 Manual. HB130 CP 341-1CH01 en CP 341 RS422/485.

VIPA System 300S. CP 341-1CH01 Manual. HB130 CP 341-1CH01 en CP 341 RS422/485. VIPA System 300S CP 341-1CH01 Manual HB130 CP 341-1CH01 en 18-40 CP 341 RS422/485 www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132

More information

PAS 300, PROFIBUS Slave Interface Module

PAS 300, PROFIBUS Slave Interface Module Catalog 08 PROFIBUS-Components 27 PAS 300, PROFIBUS Slave Interface Module PROFIBUS PROFIBUS slave interfaces PROFIBUS slave module The PROFIBUS slave interface module PAS 300 from the Systeme Helmholz

More information

User Manual Gateway component for EtherNet/IP

User Manual Gateway component for EtherNet/IP User Manual Gateway component for EtherNet/IP PR100066 1/7/2016 Table of Contents KUNBUS GmbH Table of Contents 1 General Information... 3 1.1 Disclaimer... 3 1.2 Notes Regarding this User Manual... 4

More information

Manual. VIPA System 300S SPEED7 - CPU SC 314-6CG03. Order No.: VIPA HB140E_CPU_SC Reference: RE_314-6CG03 Rev. 09/20

Manual. VIPA System 300S SPEED7 - CPU SC 314-6CG03. Order No.: VIPA HB140E_CPU_SC Reference: RE_314-6CG03 Rev. 09/20 Manual VIPA System 300S SPEED7 - CPU SC 314-6CG03 Order No: VIPA HB140E_CPU_SC Reference: RE_314-6CG03 Rev 09/20 This manual is part of the documentation package with order number VIPA HB140E_CPU_SC and

More information

VIPA System 300S CPU 315-4PN12 Manual

VIPA System 300S CPU 315-4PN12 Manual VIPA System 300S CPU 315-4PN12 Manual HB140 CPU 315-4PN12 GB 14-29 VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: 09132-744-0 Fax: 09132-744-1864 email: info@vipa.com Internet: www.vipa.com 315-4PN12_000_CPU

More information

Quick Start Guide NETL ink Ethernet Gateways

Quick Start Guide NETL ink Ethernet Gateways Version en as of FW. Quick Start Guide NETL ink Ethernet Gateways www.helmholz.com Content. Introduction. Checking the Network Situation. Preparing the NETL ink. IP Address Settings on the PG/PC Network

More information

VIPA SPEED7 Library. OPL_SP7-LIB SW90BS0MA Manual. HB00 OPL_SP7-LIB SW90BS0MA en Block library - Modbus Communication

VIPA SPEED7 Library. OPL_SP7-LIB SW90BS0MA Manual. HB00 OPL_SP7-LIB SW90BS0MA en Block library - Modbus Communication VIPA SPEED7 Library OPL_SP7-LIB SW90BS0MA Manual HB00 OPL_SP7-LIB SW90BS0MA en 17-35 Block library - Modbus Communication www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074 Herzogenaurach

More information

MultiModem rcell. Intelligent Wireless Router. Quick Start Guide

MultiModem rcell. Intelligent Wireless Router. Quick Start Guide MultiModem rcell Intelligent Wireless Router Quick Start Guide Copyright and Technical Support Quick Start Guide MultiModem rcell MTCBA-Xx-EN2 82100400L, Revision A Copyright 2009 by Multi-Tech Systems,

More information

VIPA System 300S CPU 317SN/PN

VIPA System 300S CPU 317SN/PN CPU 317-4PN12 Manual HB140 CPU 317-4PN12 GB 15-12 VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: 09132-744-0 Fax: 09132-744-1864 Email: info@vipa.com Internet: www.vipa.com 317-4PN12_000_CPU 317SN/PN,2,GB

More information

VIPA System 300S + CPU 315-2AG23 Manual. HB140 CPU 315-2AG23 en SPEED7 CPU 315SB.

VIPA System 300S + CPU 315-2AG23 Manual. HB140 CPU 315-2AG23 en SPEED7 CPU 315SB. VIPA System 300S + CPU 315-2AG23 Manual HB140 CPU 315-2AG23 en 18-01 SPEED7 CPU 315SB www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49

More information

VIPA System 300S + CPU 314-2BG23 Manual HB140 CPU 314-2BG23 GB SPEED7 CPU 314SE

VIPA System 300S + CPU 314-2BG23 Manual HB140 CPU 314-2BG23 GB SPEED7 CPU 314SE VIPA System 300S + CPU 314-2BG23 Manual HB140 CPU 314-2BG23 GB 16-36 SPEED7 CPU 314SE VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132 744-1864 Email: info@vipa.com Internet:

More information

VIPA System 300S CPU 315-4PN33 Manual

VIPA System 300S CPU 315-4PN33 Manual CPU 315-4PN33 Manual HB140 CPU 315-4PN33 GB 14-43 VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: 09132-744-0 Fax: 09132-744-1864 email: info@vipa.com Internet: www.vipa.com 315-4PN33_000_CPU 315SN/PN

More information

Manual Version: V1.00. Video Decoder Quick Guide

Manual Version: V1.00. Video Decoder Quick Guide Manual Version: V1.00 Video Decoder Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

VIPA System 300S. CP 343-1EX71 Manual. HB140 CP 343-1EX71 en SPEED7 CP 343S-NET.

VIPA System 300S. CP 343-1EX71 Manual. HB140 CP 343-1EX71 en SPEED7 CP 343S-NET. VIPA System 300S CP 343-1EX71 Manual HB140 CP 343-1EX71 en 17-15 SPEED7 CP 343S-NET www.vipa.com/en/service-support/manual VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132

More information

VIPA System 300S + CPU-SC 314-6CG23 Manual HB140 CPU-SC 314-6CG23 GB SPEED7 CPU 314SC/DPM

VIPA System 300S + CPU-SC 314-6CG23 Manual HB140 CPU-SC 314-6CG23 GB SPEED7 CPU 314SC/DPM CPU-SC 314-6CG23 Manual HB140 CPU-SC 314-6CG23 GB 16-30 SPEED7 CPU 314SC/DPM VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132 744-1864 Email: info@vipa.com Internet: www.vipa.com

More information

General Operating, Maintenance and Installation Manual

General Operating, Maintenance and Installation Manual General Operating, Maintenance and Installation Manual Hardware Platform for Protocol Converter Small Embedded Controller - SEC2-91056 Erlangen Telephone +49 9131 92076-0 Fax: +49 9131 92076-10 Internet:

More information

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013 Aarlogic TER-GX910 Product description Rev.9 17/03/2013 Contents 1 Overview... 3 2 Hardware Interface Description... 3 2.1 Main features of the TER-GX910... 3 2.2 Hardware block diagram... 4 3 Interface

More information

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional Setting up security in STEP 7 Professional SIMATIC NET Industrial Ethernet Security Setting up security in STEP 7 Professional Preface 1 User interface and menu commands 2 Basic configuration 3 Firewall

More information

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E Operating Instructions (Compact) 1 SIMATIC Industrial PC Release 11/2006 A5E00344128-04 Siemens Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety,

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information

PCAN-Router FD Universal, programmable Converter for CAN FD and CAN. User Manual. Document version ( )

PCAN-Router FD Universal, programmable Converter for CAN FD and CAN. User Manual. Document version ( ) PCAN-Router FD Universal, programmable Converter for CAN FD and CAN User Manual Document version 1.0.1 (2017-01-27) Relevant products Product Name Model Part number PCAN-Router FD 2 D-Sub connectors IPEH-002214

More information

ewon Flexy 2 Serial Ports Ext. Card FLA 3301

ewon Flexy 2 Serial Ports Ext. Card FLA 3301 Installation Guide IG 016 / Rev. 1.2 FLA 3301 This Installation Guide explains how to install the 2 Serial Ports Extension Card FLA 3301. support.ewon.biz Table of Contents 1. Product Summary... 3 2. Safety,

More information

Installation Instructions VIPA FM355 / R355. 4/8-Channel Controller Module for Siemens S7-300 and Vipa System 300V /10.

Installation Instructions VIPA FM355 / R355. 4/8-Channel Controller Module for Siemens S7-300 and Vipa System 300V /10. Installation Instructions VIPA FM355 / R355 4/8-Channel Controller Module for Siemens S7-300 and Vipa System 300V 3-349-355-29 6/10.09 Contents Page 1 Safety Precautions.....................................................

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

HEC. General Operating, Maintenance and Installation Manual

HEC. General Operating, Maintenance and Installation Manual HEC General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet : http://www.ipcomm.de Email: info@ipcomm.de Edition November 2005 Version

More information

Manual VIPA HMI CC 03

Manual VIPA HMI CC 03 Manual VIPA HMI CC 03 Order no.: VIPA HB116E_CC03 Rev. 07/50 Lerrzeichen Manual VIPA HMI About this manual The information in this manual is supplied without warranties. Information is subject to change

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

Installation Manual TH LINK PROFINET. Version: EN Copyright 2014 Softing Industrial Automation GmbH

Installation Manual TH LINK PROFINET. Version: EN Copyright 2014 Softing Industrial Automation GmbH Installation Manual TH LINK PROFINET Version: EN-201410-1.00 Copyright 2014 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds to the

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E Rev. 2 December 2011 PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service.... 2 Disconnect Power Connections,

More information

Network nodes with gateway

Network nodes with gateway 2 878 Siemeca AMR Network nodes with gateway WTX16.GSM WTX16.IP WTX16.MOD The WT 16 network nodes are used to receive and handle the data transmitted by consumption meters of the Siemeca AMR system. They

More information

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013 Aarlogic TER-GX910 Product description Rev.9 17/03/2013 Contents 1 Overview... 3 2 Hardware Interface Description... 3 2.1 Main features of the TER-GX910... 3 2.2 Hardware block diagram... 4 3 Interface

More information

S7-200 PPI Monomaster Remote connection How To

S7-200 PPI Monomaster Remote connection How To ewon Application User Guide AUG 017 / Rev 1.0 You Select, We Connect S7-200 PPI Monomaster Remote connection How To Content The purpose of this guide is to explain in a few steps how to configure your

More information

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview GT- HE910-EUD Product description Rev. 8 21/02/2013 1. Overview The GT-HE910-EUD is a complete Cellular Terminal solution for GSM/UMTS applications. Based on Telit HE910-EUD module. 1 Hardware Interface

More information

VIPA SPEED7 Library. OPL_SP7-LIB SW90ES0MA V Manual. HB00 OPL_SP7-LIB SW90ES0MA V en Block library - Building Control

VIPA SPEED7 Library. OPL_SP7-LIB SW90ES0MA V Manual. HB00 OPL_SP7-LIB SW90ES0MA V en Block library - Building Control VIPA SPEED7 Library OPL_SP7-LIB SW90ES0MA V10.003 Manual HB00 OPL_SP7-LIB SW90ES0MA V10.003 en 18-45 Block library - Building Control www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074 Herzogenaurach

More information

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11 Data Sheet Communication Unit 560CMD11 Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks.

More information

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4 Preface 1 Scope of Delivery 2 Product Characteristics 3 Industrial I/O-Node ION PROFIBUS DP SPY T001 Installation and Maintenance 4 6AT8000-1BA00-5XA0 Notes on the CE Mark 5 References 6 Appendix 7 Release

More information

Siemens Drives & PLCs

Siemens Drives & PLCs Automation System S7-300: Getting Started CPU 31xC: Commissioning Introduction 1 Preparation 2 SIMATIC S7-300 Automation System S7-300: Getting Started CPU 31xC: Commissioning Learning units 3 Further

More information

MultiModem rcell Intelligent Wireless Router. Quick Start Guide

MultiModem rcell Intelligent Wireless Router. Quick Start Guide MultiModem rcell Intelligent Wireless Router Quick Start Guide Copyright and Technical Support Quick Start Guide MultiModem rcell MTCBA-Xx-EN2, MTCBA-Xx-EN2-GP 82100511L, Revision A Copyright 2010 by Multi-Tech

More information

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11 Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service... 2 Disconnect Power Connections, CTs, and Modbus....

More information

EZmoto V4.1 Product description Rev. 2 30/07/2015

EZmoto V4.1 Product description Rev. 2 30/07/2015 EZmoto V4.1 Product description Rev. 2 30/07/2015 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware

More information

Manual Version: V1.00. Video Decoder User Manual

Manual Version: V1.00. Video Decoder User Manual Manual Version: V1.00 Video Decoder User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng IntesisBox Modbus Server KILSEN KSA-7xx User s Manual 08/2013 r1.2 eng Intesis Software S.L. 2013 All rights reserved. Information in this document is subject to change without notice. The software described

More information

CM597 Ethernet Communication Module

CM597 Ethernet Communication Module Ordering Data DATA SHEET CM597 Ethernet Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 700 R0001 1SAP 373 700 R0001 CM597-ETH, communication module Ethernet

More information

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date: Installation- and Operating instructions for CU8880-0010 Ethernet Controller with USB Input Version: 1.4 Date: 2018-04-12 Table of contents Table of contents 1. 2. 3. 4. 5. General instructions 2 Notes

More information

Product and Applications Description

Product and Applications Description IP N146/02 Product and Applications Description The IP N146/02 is a DIN rail mounted device. The device implements the KNXnet/IP standard and connects KNX/EIB lines via data networks using the Internet

More information

GPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher

GPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher GPRS ADAPTER INSTALLATION AND USER MANUAL for module version v2.24 and higher Table of contents 1 Main function of the Adapter...3 2 System operation...3 2.1 Transmission through GPRS...4 2.1.1 Router

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service.... 2 Disconnect Power Connections, CTs, and Modbus....

More information

Data sheet VIPA CPU 214PG (214-2BE03)

Data sheet VIPA CPU 214PG (214-2BE03) Data sheet VIPA CPU 214PG (214-2BE03) Technical data Order. General information Note - 214-2BE03 VIPA CPU 214PG Features Work memory [KB]: 96 Interface [RJ45]: Ethernet PG/OP communication Interface [RS485]:

More information

Data sheet VIPA CPU 214NET PG (214-2BT13)

Data sheet VIPA CPU 214NET PG (214-2BT13) Data sheet VIPA CPU 214NET PG (214-2BT13) Technical data Order. 214-2BT13 VIPA CPU 214NET PG General information Note - Features Work memory [KB]: 96 Integrated Ethernet CP 243 Interface [RJ45]: active

More information