1 Extend your DB2 purescale cluster to another city- Geographically Dispersed purescale Cluster Roy Cecil IBM Session Code: 5 16 April 2014, 16:00 Platform: LUW

2 2 Agenda Introduction Disaster Recovery & High Availability Key Concepts Geographically Dispersed purescale Cluster How to build?

3 3 Data Center

4 4 Business Continuity A disaster Recovery plan should be in place to help ensure business continuity!

5 Building a DR Site -Distance is the Key Campus ( 0-10 ) Km Fire Vandalism/Terrorism Power Outages Metro ( ) Km Global Flood Hurricane Earthquakes

6 6 DR Solutions in DB2 HADR Active/Passive HA & DR solution Available in purescale from version 10.1 FP2 Both Synchronous and asynchronous operation Standby is not contributing to transaction processing until there is a need to take over. Q-Rep/CDC Active/Active or Active/Passive. Can be unidirectional or Bidirectional In the event of a site failure there might be a need for a conflict resolution GDPC - Active/Active HA & DR Solution. Both side contribute to productive work on the cluster. No loss of transaction. Fairly quick recovery times from site failures.

7 7 Types of Standby in a DR solution. Cold Standby needs to be bootstrapped and periodically synced with the Active system. Eg. DB2 backup/restore. Warm Data is replicated to the standby but data replication is not synchronous. Eg. HADR in asynchronous mode. Hot -Data is replicated to the standby synchronously Eg. HADR in synchronous mode. Active-Active Both Primary and Secondary site processes data and changes are synchronously replicated bi-directionally.

8 8 Fault Tolerance High Availability ( HA ) The ability of a system to continue operating even in the event of single or multiple component failures. Achieved by eliminating Single Point of Failures ( SPOF) - Redundancy DB2 purescale is the Gold standard for HA.

9 DB2 purescale An overview CS 2nd-ary Clients Single Database View Member Member Member Member CS CS CS CS Cluster Interconnect CS Log Log Log Log Shared Storage Access Database Primary Clients connect anywhere, see single database Clients connect into any member Automatic load balancing and client reroute may change underlying physical member to which client is connected DB2 engine runs on several host computers Co-operate with each other to provide coherent access to the database from any member Integrated cluster services Failure detection, recovery automation, cluster file system In partnership with STG (GPFS,RSCT) and Tivoli (SA MP) Low latency, high speed interconnect Special optimizations provide significant advantages on RDMA-capable interconnects like Infiniband or 10G Ethernet. Cluster Caching Facility (CF) technology Efficient global locking and buffer management Synchronous duplexing to secondary ensures availability Data sharing architecture Shared access to database Members write to their own logs Logs accessible from another host (used during recovery)

10 Active Active Disaster Recovery via Stretch cluster. A stretch or Geographically Dispersed purescale Cluster ( GDPC ) spans two sites A & B at distances of tens of Kilometers. Goal : Provide active-active access to one or more shared databases across the cluster To provide a DR plan for many types of Disasters. DB2 purescale is the Gold standard for HA. Inspired by DB2 /z Geographically Dispersed parallel Sysplex. #IDUG 10 N km M1 M3 CFP CFS M2 M4 Site A Site B

11 11 Agenda Introduction Disaster Recovery & High Availability Key Concepts Geographically Dispersed purescale Cluster How to build?

12 12 Synchronous Vs Asynchronous replication db2sysc Log buffer commit returns Storage Primary Site Secondary Site Storage db2sysc

13 13 Synchronous Vs Asynchronous replication db2sysc Log buffer commit returns Storage Primary Site Secondary Site Storage db2sysc

14 14 GDPC Uses Synchronous GPFS Replication

15 Disk storage in GDPC Mbr Mbr Member Mbr Mbr Member GPFS Shared Storage (logical view) Log Log Database Log Log Physical Storage site 'A' GPFS replication between sites Physical Storage site 'B' GPFS replication coordinates synchronous writes across sites Any write to the cluster storage from either site is replicated to the storage at the other site All storage is connected to purescale hosts at both sites via zoned SANs GPFS daemons on each server write to both site replicas directly not by passing updated pages between GPFS daemons Replication of writes and site-to-site distance causes some increase in write times for both transaction logs and containers Reads are optimized to use the local copy for best performance

16 16 Design Goals RPO / RTO / Availability RPO ( Recovery Point Objective )-Maximum tolerable period within which data loss is acceptable to the business. RTO ( Recovery Time Objective ) The time in which the system availability must be restored after a disaster. Restor e/ Sync From Backu p Disaster Time Restor e/ Sync From Backu p Operational Window RPO RTO For GDPC RPO = 0 RTO <3 min

17 17 MTBF ( Mean Time Between Failure ) calculations Mean time between failures is related to the probability of failure by the formula 1 -e -t/mtbf where t = time period where the probability is computed If the MTBF of a switch ( For eg IBM BNT G8264 ) is 18 years, the probability that the switch will fail this year is only 5%. If you have two switches then the probability that one of the switch will fail this year is 10%. In the Event of a failure ( say because of a switch failure) lets say the outage of the purescale cluster is 30 seconds. The availability of our cluster because of an outage due to a switch failure this year is calculated as»contd..

18 18 MTBF ( Mean Time Between Failure ) calculations Availability = 100 -Probability of failure * Unavailability taking into account the outage due to failure Probability of failure = 1 -e -t/mtbf In our example Probability of switch failure = 1 e -1/18 = Unavailability taking into account the outage due to switch failure = ( 30s/ s * 100 * = % ) Availability = = %

19 19 Don't forget MTBF in your Availability Calculations!

20 20 Latency Vs Bandwidth Latency is the time taken for a message to be delivered from the primary site to the secondary site. Latency is a property of the medium. Bandwidth is the rate at which data can be transferred from the primary site to the secondary site.

21 21 Can't beat the speed of light!! The fastest we can send a piece of information is if we use photons to carry the message! The speed of light is a constant in a medium. ( * 10 8 meters per second in vacuum ) The latency of a light signal in vacuum is hence 3.3 μs per Km. The latency of light signal in fiber optic medium is 5μs per Km. ( 3.3 * refractive index of glass ) We have to live with this latency!!

22 22 Remote Direct Memory Access. ( RDMA ) User Buffer Process User Buffer Process User User Kernel Buffer Kernel Buffer NIC NIC Switched Fabric

23 23 10GE or Infiniband? OR 10 GE Network Infiniband Network DB2 purescale supports both 10GE & Infiniband GDPC can be deployed on both 10GE and Infiniband over WAN/dark-fiber Does it really matter much? -No!

24 Long Distance IB. Typical Infiniband connectivity reaches at most m Specialized cables allow up to a few hundred meters DB2/z GDPS achieves long distances with specialized HCA2-O LR optical coupling adapter + repeaters DB2 purescale GDPC uses IBTA-compliant range extenders For example, Obsidian Longbow extenders Used in pairs, appear in network as a 2-port IB switch Convert duplex IB traffic to dark fiber or 10 GE WAN traffic Other vendors in this space include Bay Microsystems & Mellanox Longbow C-103 Longbow E-100

25 Long Distance RoCE RoCE is compatible with 10GE WAN and hence would not require special range extenders like Infiniband. We would still require transceivers at both endpoints to be able to extend the reach of the RDMA traffic ( SFP LR or ER transceivers depending on the distance)

26 AIX or Linux? GDPC is supported on both AIX/Linux. Current support Matrix is purely based on customer demand Support Matrix as of DB2 LUW 10.5 FP3 AIX RHEL SLES 10GE Infiniband

27 27 You are in control! You have choice!

28 The 'sweet spot' of GDPC 40% Portion of UPDATE / INSERT / DELETE in workload 30% 20% 10% 0% Best candidate workloads / configurations for GDPC Better candidates for HADR,QRep, CDC or storage replication between sites 10km 20km 30km 40km 50km 60km Site-to-site distance

29 29 Dark Fiber or 10GE WAN? Dark fiber refers to unlit fiber that can be leased from an ISP and provides point-to-point connectivity between two sites. 10GE WAN can also be used to connect the two sites. Require sufficient bandwidth to carry 10GE traffic ( 10GE or IB QDR ) eg. OC-192 The exact bandwidth requirement for your installation can be measured by looking at the switch statistics.

30 30 SAN traffic Each site needs to have zoned access to the storage on the other site. SAN traffic can go on its own link or can be multiplexed into a single link using DWDM switches.

31 Improving Availability- Quorum Considerations. DB2 purescale is built on two clustering technologies. GPFS for storage TSA/RSCT to automate the resources in a purescale cluster. #IDUG Both of these clusters can be operated when there is a majority of nodes active in the cluster. If an equal number of nodes are distributed across two sites, then in the event of a failure there is a loss of quorum. Since a site outage brings a surviving site one vote shy of quorum a third node is added to ensure that single site outage still do not cause the surviving site to go down. This node is added in a third site ( Tiebreaker) and only require Ethernet connectivity 31

32 32 Tiebreaker site. Tiebreaker site do not run members or CF but is part of RSCT peer-domain and GPFS cluster. The tie-breaker hosts a storage with one disk per file-system to provide disk descriptor quorum to the GPFS replicated filesystem. If SCSI-3PR is not enabled ( ie. Fast fencing is not required) the tiebreaker site do not need direct access to disks of the other two sites. If SCSI-3PR is required, each site including the tie-breaker needs to have direct access to the disks on the other two sites. Tiebreaker site do not mount any of the filesystems.

33 33 Putting it all together!

34 Comparing single-site & GDPC configurations. Infiniband Infiniband switch Single-site purescale configuration Mbr 1 Ethernet Mbr 3 CF pri CF sec Mbr 2 Fiber Channel Mbr 4 Log Log Log Log GPFS Shared Storage (logical view) Database Physical Storage Infiniband + IPoIB N km Dark Fiber or WAN IB range extender GDPC purescale configuration Mbr 1 Ethernet Mbr 3 CF pri 3 rd Site tie-breaker Database CF sec GPFS Shared Storage (logical view) Log Log Log Log Mbr 2 Mbr 4 Fiber Channel Physical Storage site 'A' GPFS replication between sites Physical Storage site 'B'

35 Failure Detection Cluster Services ( TSA )- RSCT Heartbeats Single Node Multiple Node RSCT ( RMC framework ) Adapter Failures Storage Failures ( GPFS ) Inter Site Link / Longbow ( GPFS )

36 Target Scenario in the event of a site failure. Client Client Client Client Client Applications Application Application Application #IDUG Both sites are active and available during normal operation. In the event of failure, client connections are automatically redirected to the surviving site by Workload Balancing ( WLB ) and Automatic client Reroute ( ACR ) Applies to both individual members within site and total site failure Connections balanced with Workload Balancing N km M1 M3 CFP CFS M2 M4 Site A Site B

37 What do I need for a GDPC deployment? Existing dark fiber (DWDM) or WAN connection between sites A & B With required infrastructure (e.g. repeaters) for the distance involved A third tie-breaker site with Ethernet connectivity to sites A & B Enables automatic recovery from complete failure of either site One pair of Infiniband extenders or LR Trancievers SAN infrastructure to support GPFS replication between sites A & B All storage must be 'visible' at both sites for access in the event of site failure See GPFS redbook for additional details on GPFS replication Client connectivity to sites A & B Interested? Please contact go_db2@ca.ibm.com for more information on deployment and next steps.

38 More information about GDPC configurations & services 2Fcom.ibm.db2.luw.licensing.doc%2Fdoc%2Fc html Concepts Comparisons with single-site purescale cluster configurations Setup procedure

39 Questions? #IDUG

40 Roy Cecil IBM Session 5 Title Extend your DB2 purescale cluster to another city- Geographically Dispersed purescale Cluster Please fill out your session evaluation before leaving!

DB2 purescale: High Performance with High-Speed Fabrics. Author: Steve Rees Date: April 5, 2011

DB2 purescale: High Performance with High-Speed Fabrics. Author: Steve Rees Date: April 5, 2011 DB2 purescale: High Performance with High-Speed Fabrics Author: Steve Rees Date: April 5, 2011 www.openfabrics.org IBM 2011 Copyright 1 Agenda Quick DB2 purescale recap DB2 purescale comes to Linux DB2

More information

Session: Oracle RAC vs DB2 LUW purescale. Udo Brede Quest Software. 22 nd November :30 Platform: DB2 LUW

Session: Oracle RAC vs DB2 LUW purescale. Udo Brede Quest Software. 22 nd November :30 Platform: DB2 LUW Session: Oracle RAC vs DB2 LUW purescale Udo Brede Quest Software 22 nd November 2011 10:30 Platform: DB2 LUW 1 Agenda Marketing Message Clustering/Scalability Technology Overview Basic Components Available

More information

DB2 LUW HADR and purescale demystified Cristian Molaro MConsulting Bvba

DB2 LUW HADR and purescale demystified Cristian Molaro MConsulting Bvba #IDUG DB2 LUW HADR and purescale demystified Cristian Molaro MConsulting Bvba Session Code: 16 April 2014 Platform: LUW About the speaker Cristian Molaro, MConsulting Bvba, Belgium Independent DB2 specialist

More information

EMC VPLEX Geo with Quantum StorNext

EMC VPLEX Geo with Quantum StorNext White Paper Application Enabled Collaboration Abstract The EMC VPLEX Geo storage federation solution, together with Quantum StorNext file system, enables a global clustered File System solution where remote

More information

Achieve Breakthrough Performance and Availability with DB2 purescale

Achieve Breakthrough Performance and Availability with DB2 purescale Achieve Breakthrough Performance and Availability with DB2 purescale Philip K. Gunning Gunning Technology Solutions, LLC Session Code: D01 May 3, 2011 12:45 1:45 PM Platform: LUW Building the case for

More information

High Availability for Linux on IBM System z Servers

High Availability for Linux on IBM System z Servers High Availability for Linux on IBM System z s Scott Loveland IBM Systems and Technology Group Poughkeepsie, NY d10swl1@us.ibm.com May 28, 2008 Trademarks The following are trademarks of the International

More information

Network Layer Flow Control via Credit Buffering

Network Layer Flow Control via Credit Buffering Network Layer Flow Control via Credit Buffering Fibre Channel maintains throughput in the data center by using flow control via buffer to buffer credits Nominally switches provide credit buffering up to

More information

StarWind Virtual SAN Windows Geo-Clustering: SQL Server

StarWind Virtual SAN Windows Geo-Clustering: SQL Server #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Windows Geo-Clustering: SQL Server FEBRUARY 2016 TECHNICAL PAPER EDWIN SARMIENTO, Microsoft SQL Server MVP, Microsoft Certified Master

More information

Business Continuity and Disaster Recovery. Ed Crowley Ch 12

Business Continuity and Disaster Recovery. Ed Crowley Ch 12 Business Continuity and Disaster Recovery Ed Crowley Ch 12 Topics Disaster Recovery Business Impact Analysis MTBF and MTTR RTO and RPO Redundancy Failover Backup Sites Load Balancing Mirror Sites Disaster

More information

DB2 PureScale SAS Grid -in a Risk environment. Philip Källander, Patric Hamilton, Rickard Linck

DB2 PureScale SAS Grid -in a Risk environment. Philip Källander, Patric Hamilton, Rickard Linck DB2 PureScale SAS Grid -in a Risk environment Philip Källander, Patric Hamilton, Rickard Linck Background RICI Project initiated 2009 The system went live 2011 First year focus was on sourcing data Since

More information

High Availability for Highly Reliable Systems

High Availability for Highly Reliable Systems High Availability for Highly Reliable Systems Mike Friesenegger SUSE Wednesday, February 6, 2013 Session: 12367 Agenda What is a high availability (HA) cluster? What is required to build a HA cluster using

More information

Extending InfiniBand Globally

Extending InfiniBand Globally Extending InfiniBand Globally Eric Dube (eric@baymicrosystems.com) com) Senior Product Manager of Systems November 2010 Bay Microsystems Overview About Bay Founded in 2000 to provide high performance networking

More information

EMC VPLEX with Quantum Stornext

EMC VPLEX with Quantum Stornext White Paper Application Enabled Collaboration Abstract The EMC VPLEX storage federation solution together with Quantum StorNext file system enables a stretched cluster solution where hosts has simultaneous

More information

iscsi Target Usage Guide December 15, 2017

iscsi Target Usage Guide December 15, 2017 December 15, 2017 1 Table of Contents 1. Native VMware Availability Options for vsan 1.1.Native VMware Availability Options for vsan 1.2.Application Clustering Solutions 1.3.Third party solutions 2. Security

More information

Disaster Recovery (DR) Planning with the Cloud Desktop

Disaster Recovery (DR) Planning with the Cloud Desktop with the Cloud Desktop Info@RIAWorkSpace.com 877.361.3499 www.riaworkspace.com In preparing for the unexpected, most companies put specific disaster recovery plans in place. Without planning, recovering

More information

White Paper. How to select a cloud disaster recovery method that meets your requirements.

White Paper. How to select a cloud disaster recovery method that meets your requirements. How to select a cloud disaster recovery method that meets your requirements. VS Table of contents Table of contents Page 2 Executive Summary Page 3 Introduction Page 3 Disaster Recovery Methodologies Page

More information

IBM DB2 Analytics Accelerator High Availability and Disaster Recovery

IBM DB2 Analytics Accelerator High Availability and Disaster Recovery Redpaper Patric Becker Frank Neumann IBM Analytics Accelerator High Availability and Disaster Recovery Introduction With the introduction of IBM Analytics Accelerator, IBM enhanced for z/os capabilities

More information

The Right Choice for DR: Data Guard, Stretch Clusters, or Remote Mirroring. Ashish Ray Group Product Manager Oracle Corporation

The Right Choice for DR: Data Guard, Stretch Clusters, or Remote Mirroring. Ashish Ray Group Product Manager Oracle Corporation The Right Choice for DR: Data Guard, Stretch Clusters, or Remote Mirroring Ashish Ray Group Product Manager Oracle Corporation Causes of Downtime Unplanned Downtime Planned Downtime System Failures Data

More information

Cisco Virtualized Workload Mobility Introduction

Cisco Virtualized Workload Mobility Introduction CHAPTER 1 The ability to move workloads between physical locations within the virtualized Data Center (one or more physical Data Centers used to share IT assets and resources) has been a goal of progressive

More information

PURE STORAGE PURITY ACTIVECLUSTER

PURE STORAGE PURITY ACTIVECLUSTER PURE STORAGE PURITY ACTIVECLUSTER Contents Overview... 4 Introduction... 4 Core Components... 5 Administration... 6 Deployment Options... 6 Uniform Storage Access... 6 Optimizing Performance in Uniform

More information

Agenda. What is Replication?

Agenda. What is Replication? !"#$%% "#&'( Agenda What is Replication? Why Replicate? Approaches to Replication Master/Slave Disconnected Repositories (Git / Bitkeeper / Mercurial / Bazaar) Active/Active Master/Slave vs Active/Active

More information

VPLEX Networking. Implementation Planning and Best Practices

VPLEX Networking. Implementation Planning and Best Practices VPLEX Networking Implementation Planning and Best Practices Internal Networks Management Network Management VPN (Metro/Witness) Cluster to Cluster communication (WAN COM for Metro) Updated for GeoSynchrony

More information

High Availability Scenarios for Oracle Databases on IBM z Systems

High Availability Scenarios for Oracle Databases on IBM z Systems High Availability Scenarios for Oracle Databases on IBM z Systems Sam Amsavelu Oracle on z Architect IBM ISV & Channels Technical Sales Oracle samvelu@us.ibm.com 29 th Annual International Oracle on IBM

More information

Exam Name: Midrange Storage Technical Support V2

Exam Name: Midrange Storage Technical Support V2 Vendor: IBM Exam Code: 000-118 Exam Name: Midrange Storage Technical Support V2 Version: 12.39 QUESTION 1 A customer has an IBM System Storage DS5000 and needs to add more disk drives to the unit. There

More information

Exam : S Title : Snia Storage Network Management/Administration. Version : Demo

Exam : S Title : Snia Storage Network Management/Administration. Version : Demo Exam : S10-200 Title : Snia Storage Network Management/Administration Version : Demo 1. A SAN architect is asked to implement an infrastructure for a production and a test environment using Fibre Channel

More information

DB2 purescale Active/Active High Availability is Here!

DB2 purescale Active/Active High Availability is Here! purescale Active/Active High Availability is Here! Session C04, for LUW Aamer Sachedina STSM, IBM Toronto Lab November 9, 2010, 8:30am 0 purescale is state of the art for LUW technology which offers active/active

More information

HUAWEI OceanStor Enterprise Unified Storage System. HyperReplication Technical White Paper. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI OceanStor Enterprise Unified Storage System. HyperReplication Technical White Paper. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OceanStor Enterprise Unified Storage System HyperReplication Technical White Paper Issue 01 Date 2014-03-20 HUAWEI TECHNOLOGIES CO., LTD. 2014. All rights reserved. No part of this document may

More information

Module 2 Storage Network Architecture

Module 2 Storage Network Architecture Module 2 Storage Network Architecture 1. SCSI 2. FC Protocol Stack 3. SAN:FC SAN 4. IP Storage 5. Infiniband and Virtual Interfaces FIBRE CHANNEL SAN 1. First consider the three FC topologies pointto-point,

More information

Best Practices. The DB2 purescale Feature on SUSE Linux Enterprise Server; A best-ofbreed Solution Stack for SAP Business Applications

Best Practices. The DB2 purescale Feature on SUSE Linux Enterprise Server; A best-ofbreed Solution Stack for SAP Business Applications IBM DB2 for Linux, UNIX, and Windows Best Practices The DB2 purescale Feature on SUSE Linux Enterprise Server; A best-ofbreed Solution Stack for SAP Business Applications Issued April 2011 The DB2 purescale

More information

Storage System. David Southwell, Ph.D President & CEO Obsidian Strategics Inc. BB:(+1)

Storage System. David Southwell, Ph.D President & CEO Obsidian Strategics Inc. BB:(+1) Storage InfiniBand Area Networks System David Southwell, Ph.D President & CEO Obsidian Strategics Inc. BB:(+1) 780.964.3283 dsouthwell@obsidianstrategics.com Agenda System Area Networks and Storage Pertinent

More information

EBOOK. FROM DISASTER RECOVERY TO ACTIVE-ACTIVE: NuoDB AND MULTI-DATA CENTER DEPLOYMENTS

EBOOK. FROM DISASTER RECOVERY TO ACTIVE-ACTIVE: NuoDB AND MULTI-DATA CENTER DEPLOYMENTS FROM DISASTER RECOVERY TO ACTIVE-ACTIVE: NuoDB AND MULTI-DATA CENTER DEPLOYMENTS INTRODUCTION Traditionally, multi-data center strategies were deployed primarily to address disaster recovery scenarios.

More information

SAN for Business Continuity

SAN for Business Continuity SAN for Business Continuity How Cisco IT Achieves Subminute Recovery Point Objective A Cisco on Cisco Case Study: Inside Cisco IT 1 Overview Challenge Improve recovery point objective (RPO) and recovery

More information

Datacenter replication solution with quasardb

Datacenter replication solution with quasardb Datacenter replication solution with quasardb Technical positioning paper April 2017 Release v1.3 www.quasardb.net Contact: sales@quasardb.net Quasardb A datacenter survival guide quasardb INTRODUCTION

More information

How To Make Databases on Linux on System z Highly Available

How To Make Databases on Linux on System z Highly Available How To Make Databases on Linux on System z Highly Available Mike Friesenegger (mikef@suse.com) SUSE Wednesday, August 14, 2013 Session Number 13437 Agenda Clarify the term "Availability" What is High Availability

More information

HIGH-AVAILABILITY & D/R OPTIONS FOR MICROSOFT SQL SERVER

HIGH-AVAILABILITY & D/R OPTIONS FOR MICROSOFT SQL SERVER SQL SATURDAY # 91 - OMAHA HIGH-AVAILABILITY & D/R OPTIONS FOR MICROSOFT SQL SERVER 8/27/11 Tim Plas, Virteva tim.plas@virteva.com 1 The Presenter Tim Plas, Principal Consultant at Virteva (Mpls) Operational

More information

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme STO1297BE Stretched Clusters or VMware Site Recovery Manager? We Say Both! Jeff Hunter, VMware, @jhuntervmware GS Khalsa, VMware, @gurusimran #VMworld Disclaimer This presentation may contain product features

More information

InfiniBand and Next Generation Enterprise Networks

InfiniBand and Next Generation Enterprise Networks InfiniBand and Next Generation Enterprise Networks Paul Morkel and Brian Savory ADVA Optical Networking The pace of technical innovation is accelerating Adoption of new technologies are taking hold at

More information

Security+ Guide to Network Security Fundamentals, Third Edition. Chapter 13 Business Continuity

Security+ Guide to Network Security Fundamentals, Third Edition. Chapter 13 Business Continuity Security+ Guide to Network Security Fundamentals, Third Edition Chapter 13 Business Continuity Objectives Define business continuity Describe the components of redundancy planning List disaster recovery

More information

Exam Questions P

Exam Questions P Exam Questions P2090-054 IBM Information Management DB2 10.5 purescale Technical Mastery Test v3 https://www.2passeasy.com/dumps/p2090-054/ 1. Which of the following memory heaps is NOT configurable on

More information

Snia S Storage Networking Management/Administration.

Snia S Storage Networking Management/Administration. Snia S10-200 Storage Networking Management/Administration http://killexams.com/exam-detail/s10-200 QUESTION: 85 What are two advantages of over-subscription? (Choose two.) A. saves on ISL links B. decreases

More information

New Storage Architectures

New Storage Architectures New Storage Architectures OpenFabrics Software User Group Workshop Replacing LNET routers with IB routers #OFSUserGroup Lustre Basics Lustre is a clustered file-system for supercomputing Architecture consists

More information

MQ High Availability and Disaster Recovery Implementation scenarios

MQ High Availability and Disaster Recovery Implementation scenarios MQ High Availability and Disaster Recovery Implementation scenarios Sandeep Chellingi Head of Hybrid Cloud Integration Prolifics Agenda MQ Availability Message Availability Service Availability HA vs DR

More information

High Availability for Cisco Unified Communications on the Cisco Unified Computing System (UC on UCS)

High Availability for Cisco Unified Communications on the Cisco Unified Computing System (UC on UCS) White Paper High Availability for Cisco Unified Communications on the Cisco Unified Computing System (UC on UCS) Updated January 2013 2012 Cisco and/or its affiliates. All rights reserved. This document

More information

Virtualization And High Availability. Howard Chow Microsoft MVP

Virtualization And High Availability. Howard Chow Microsoft MVP Virtualization And High Availability Howard Chow Microsoft MVP Session Objectives And Agenda Virtualization and High Availability Types of high availability enabled by virtualization Enabling a highly

More information

Data Center Interconnect Solution Overview

Data Center Interconnect Solution Overview CHAPTER 2 The term DCI (Data Center Interconnect) is relevant in all scenarios where different levels of connectivity are required between two or more data center locations in order to provide flexibility

More information

Business Continuity & Disaster Recovery

Business Continuity & Disaster Recovery Business Continuity & Disaster Recovery Technology and Process Alessio Di Benedetto Presales Manager Roma, 7 th of May 2010 1 Objectives The objective of this workshop is to provide: an overview of the

More information

Windows Clustering 101

Windows Clustering 101 Windows Clustering 101 Dave Bermingham, Microsoft Clustering MVP, Senior Technical Evangelist, SIOS Technology Corp. Dave Bermingham Microsoft Cluster MVP (2010-current) Founder of www.clusteringformeremortals.com

More information

Azure Webinar. Resilient Solutions March Sander van den Hoven Principal Technical Evangelist Microsoft

Azure Webinar. Resilient Solutions March Sander van den Hoven Principal Technical Evangelist Microsoft Azure Webinar Resilient Solutions March 2017 Sander van den Hoven Principal Technical Evangelist Microsoft DX @svandenhoven 1 What is resilience? Client Client API FrontEnd Client Client Client Loadbalancer

More information

vsan Disaster Recovery November 19, 2017

vsan Disaster Recovery November 19, 2017 November 19, 2017 1 Table of Contents 1. Disaster Recovery 1.1.Overview 1.2.vSAN Stretched Clusters and Site Recovery Manager 1.3.vSAN Performance 1.4.Summary 2 1. Disaster Recovery According to the United

More information

A Continuous Availability Solution for Virtual Infrastructure

A Continuous Availability Solution for Virtual Infrastructure Technical Report A Continuous Availability Solution for Virtual Infrastructure NetApp and VMware Inc. September 2009 TR-3788 EXECUTIVE SUMMARY As enterprise customers look to virtualization as a cost-effective

More information

Power Systems High Availability & Disaster Recovery

Power Systems High Availability & Disaster Recovery Power Systems High Availability & Disaster Recovery Solutions Comparison of various HA & DR solutions for Power Systems Authors: Carl Burnett, Joe Cropper, Ravi Shankar Table of Contents 1 Abstract...

More information

TSM Paper Replicating TSM

TSM Paper Replicating TSM TSM Paper Replicating TSM (Primarily to enable faster time to recoverability using an alternative instance) Deon George, 23/02/2015 Index INDEX 2 PREFACE 3 BACKGROUND 3 OBJECTIVE 4 AVAILABLE COPY DATA

More information

Simplified and Consolidated Parallel Media File System Solution

Simplified and Consolidated Parallel Media File System Solution Simplified and Consolidated Parallel Media File System Solution Presenters : Dr. M. K. Jibbe, Technical Director NetApp ESG Joey Parnell, Software Architect NetApp, ESG 2018 Storage Developer Conference.

More information

DATA PROTECTION IN A ROBO ENVIRONMENT

DATA PROTECTION IN A ROBO ENVIRONMENT Reference Architecture DATA PROTECTION IN A ROBO ENVIRONMENT EMC VNX Series EMC VNXe Series EMC Solutions Group April 2012 Copyright 2012 EMC Corporation. All Rights Reserved. EMC believes the information

More information

IBM EXAM QUESTIONS & ANSWERS

IBM EXAM QUESTIONS & ANSWERS IBM 000-452 EXAM QUESTIONS & ANSWERS Number: 000-452 Passing Score: 800 Time Limit: 120 min File Version: 68.8 http://www.gratisexam.com/ IBM 000-452 EXAM QUESTIONS & ANSWERS Exam Name: IBM Storwize V7000

More information

IBM DB2 purescale Feature for Enterprise Server Edition Version 9 Release 8. DB2 purescale Feature Installation and Upgrade Guide

IBM DB2 purescale Feature for Enterprise Server Edition Version 9 Release 8. DB2 purescale Feature Installation and Upgrade Guide IBM DB2 purescale Feature for Enterprise Serer Edition Version 9 Release 8 DB2 purescale Feature Installation and Upgrade Guide IBM DB2 purescale Feature for Enterprise Serer Edition Version 9 Release

More information

New England Data Camp v2.0 It is all about the data! Caregroup Healthcare System. Ayad Shammout Lead Technical DBA

New England Data Camp v2.0 It is all about the data! Caregroup Healthcare System. Ayad Shammout Lead Technical DBA New England Data Camp v2.0 It is all about the data! Caregroup Healthcare System Ayad Shammout Lead Technical DBA ashammou@caregroup.harvard.edu About Caregroup SQL Server Database Mirroring Selected SQL

More information

Cisco I/O Accelerator Deployment Guide

Cisco I/O Accelerator Deployment Guide Cisco I/O Accelerator Deployment Guide Introduction This document provides design and configuration guidance for deploying the Cisco MDS 9000 Family I/O Accelerator (IOA) feature, which significantly improves

More information

Dale McInnis STSM / NA Data Server Tech Sales IBM Canada Ltd. The 5 W s of HADR IBM Corporation

Dale McInnis STSM / NA Data Server Tech Sales IBM Canada Ltd. The 5 W s of HADR IBM Corporation Dale McInnis STSM / NA Data Server Tech Sales IBM Canada Ltd. The 5 W s of HADR Please note IBM Corporation 2017. All rights reserved. U.S. Government Users Restricted Rights - use, duplication, or disclosure

More information

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange 2007

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange 2007 Enterprise Solutions for Microsoft Exchange 2007 EMC CLARiiON CX3-40 Metropolitan Exchange Recovery (MER) for Exchange Server Enabled by MirrorView/S and Replication Manager Reference Architecture EMC

More information

DELL EMC UNITY: REPLICATION TECHNOLOGIES

DELL EMC UNITY: REPLICATION TECHNOLOGIES DELL EMC UNITY: REPLICATION TECHNOLOGIES A Detailed Review ABSTRACT This white paper explains the replication solutions for Dell EMC Unity systems. This paper outlines the native and non-native options

More information

Managing Copy Services

Managing Copy Services This chapter contains the following sections: Copy Services, page 1 Consistency Groups, page 10 Copy Services Both IBM Storwize and IBM SAN Volume Controllers provide Copy Services functions that enable

More information

iscsi Technology Brief Storage Area Network using Gbit Ethernet The iscsi Standard

iscsi Technology Brief Storage Area Network using Gbit Ethernet The iscsi Standard iscsi Technology Brief Storage Area Network using Gbit Ethernet The iscsi Standard On February 11 th 2003, the Internet Engineering Task Force (IETF) ratified the iscsi standard. The IETF was made up of

More information

Enabling Fast Recovery of Your Virtual Environments: NetBackup, Backup Exec & VCS for VMware

Enabling Fast Recovery of Your Virtual Environments: NetBackup, Backup Exec & VCS for VMware Enabling Fast Recovery of Your Environments: NetBackup, Backup Exec & VCS for VMware Agenda 1 Symantec and ization 2 NetBackup 6.5 for VMWare 3 Backup Exec & Backup Exec System Recovery for VMWare 4 Veritas

More information

IBM TotalStorage SAN Switch F08

IBM TotalStorage SAN Switch F08 Entry workgroup fabric connectivity, scalable with core/edge fabrics to large enterprise SANs IBM TotalStorage SAN Switch F08 Entry fabric switch with high performance and advanced fabric services Highlights

More information

SRX Services Gateway Cluster Deployments Across Layer Two Networks. Deployment requirements for SRX cluster connectivity across layer two networks

SRX Services Gateway Cluster Deployments Across Layer Two Networks. Deployment requirements for SRX cluster connectivity across layer two networks SRX Services Gateway Cluster Deployments Across Layer Two Networks Deployment requirements for SRX cluster connectivity across layer two networks Introduction Stateful firewall clustering has traditionally

More information

GR Reference Models. GR Reference Models. Without Session Replication

GR Reference Models. GR Reference Models. Without Session Replication , page 1 Advantages and Disadvantages of GR Models, page 6 SPR/Balance Considerations, page 7 Data Synchronization, page 8 CPS GR Dimensions, page 9 Network Diagrams, page 12 The CPS solution stores session

More information

Disaster Recovery Options

Disaster Recovery Options Disaster Recovery Options Balancing Pros and Cons, Objectives and Cost This ebook is written for both technology and non-technology executives who want to know their options and create a plan that appropriately

More information

Transport is now key for extended SAN applications. Main factors required in SAN interconnect transport solutions are:

Transport is now key for extended SAN applications. Main factors required in SAN interconnect transport solutions are: E Transport is now key for extended SAN applications. Main factors required in SAN interconnect transport solutions are: Native support for all SAN protocols including ESCON, Fibre Channel and Gigabit

More information

What's in this guide... 4 Documents related to NetBackup in highly available environments... 5

What's in this guide... 4 Documents related to NetBackup in highly available environments... 5 Contents Chapter 1 About in this guide... 4 What's in this guide... 4 Documents related to NetBackup in highly available environments... 5 Chapter 2 NetBackup protection against single points of failure...

More information

Consolidated Disaster Recovery. Paul Kangro Applied Technology Strategiest

Consolidated Disaster Recovery. Paul Kangro Applied Technology Strategiest Consolidated Disaster Recovery Paul Kangro Applied Technology Strategiest 2008.10.22 Presentation Overview About PlateSpin Technology Overview State of Disaster Recovery Introducing PlateSpin Forge Product

More information

Module 4 STORAGE NETWORK BACKUP & RECOVERY

Module 4 STORAGE NETWORK BACKUP & RECOVERY Module 4 STORAGE NETWORK BACKUP & RECOVERY BC Terminology, BC Planning Lifecycle General Conditions for Backup, Recovery Considerations Network Backup, Services Performance Bottlenecks of Network Backup,

More information

Clustering In A SAN For High Availability

Clustering In A SAN For High Availability Clustering In A SAN For High Availability Steve Dalton, President and CEO Gadzoox Networks September 2002 Agenda What is High Availability? The differences between High Availability, System Availability

More information

<Insert Picture Here> Exadata Hardware Configurations and Environmental Information

<Insert Picture Here> Exadata Hardware Configurations and Environmental Information Exadata Hardware Configurations and Environmental Information Revised July 1, 2011 Agenda Exadata Hardware Overview Environmental Information Power InfiniBand Network Ethernet Network

More information

How to license Oracle Database programs in DR environments

How to license Oracle Database programs in DR environments How to license Oracle Database programs in DR environments Author: Andra Tarata It is commonly known that the use of almost any Oracle software program requires a license. But how does that work when you

More information

Information Storage and Management TM Volume 2 of 2 Student Guide. EMC Education Services

Information Storage and Management TM Volume 2 of 2 Student Guide. EMC Education Services Information Storage and Management TM Volume 2 of 2 Student Guide EMC Education Services July 2009 1 2 Business Continuity Section 3 2009 EMC Corporation. All rights reserved. Introduction to Business

More information

SvSAN Data Sheet - StorMagic

SvSAN Data Sheet - StorMagic SvSAN Data Sheet - StorMagic A Virtual SAN for distributed multi-site environments StorMagic SvSAN is a software storage solution that enables enterprises to eliminate downtime of business critical applications

More information

BUILDING A BLOCK STORAGE APPLICATION ON OFED - CHALLENGES

BUILDING A BLOCK STORAGE APPLICATION ON OFED - CHALLENGES 3rd ANNUAL STORAGE DEVELOPER CONFERENCE 2017 BUILDING A BLOCK STORAGE APPLICATION ON OFED - CHALLENGES Subhojit Roy, Tej Parkash, Lokesh Arora, Storage Engineering [May 26th, 2017 ] AGENDA Introduction

More information

1 BRIEF / Oracle Solaris Cluster Features and Benefits

1 BRIEF / Oracle Solaris Cluster Features and Benefits Oracle Solaris Cluster is a comprehensive high availability (HA) and disaster recovery (DR) solution for Oracle SPARC and x86 environments that is based on Oracle Solaris. It combines extreme service availability

More information

From an open storage solution to a clustered NAS appliance

From an open storage solution to a clustered NAS appliance From an open storage solution to a clustered NAS appliance Dr.-Ing. Jens-Peter Akelbein Manager Storage Systems Architecture IBM Deutschland R&D GmbH 1 IBM SONAS Overview Enterprise class network attached

More information

VERITAS Cluster Server Disaster Recovery Architectures Explained

VERITAS Cluster Server Disaster Recovery Architectures Explained V ERITAS Solution Guide VERITAS Cluster Server Disaster Recovery Architectures Explained Authored by: Michelle M. Mol; Product Marketing Manager Jim Senicka; Technical Product Manager Revised for VERITAS

More information

SAP HANA Disaster Recovery with Asynchronous Storage Replication

SAP HANA Disaster Recovery with Asynchronous Storage Replication Technical Report SAP HANA Disaster Recovery with Asynchronous Storage Replication Using SnapCenter 4.0 SAP HANA Plug-In Nils Bauer, Bernd Herth, NetApp April 2018 TR-4646 Abstract This document provides

More information

Compute - 36 PCPUs (72 vcpus) - Intel Xeon E5 2686 v4 (Broadwell) - 512GB RAM - 8 x 2TB NVMe local SSD - Dedicated Host vsphere Features - vsphere HA - vmotion - DRS - Elastic DRS Storage - ESXi boot-from-ebs

More information

It also performs many parallelization operations like, data loading and query processing.

It also performs many parallelization operations like, data loading and query processing. Introduction to Parallel Databases Companies need to handle huge amount of data with high data transfer rate. The client server and centralized system is not much efficient. The need to improve the efficiency

More information

Hyperconverged Infrastructure Use Cases and Buyer s Guide

Hyperconverged Infrastructure Use Cases and Buyer s Guide Hyperconverged Infrastructure Use Cases and Buyer s Guide Ibrahim Rahmani Director, Product Marketing DataCore Software San Mateo, CA USA June 2016 Agenda Introduction Market Trends Use Cases Buyer s guide

More information

Disaster Recovery Solutions for Oracle Database Standard Edition RAC. A Dbvisit White Paper By Anton Els

Disaster Recovery Solutions for Oracle Database Standard Edition RAC. A Dbvisit White Paper By Anton Els Disaster Recovery Solutions for Oracle Database Standard Edition RAC A Dbvisit White Paper By Anton Els Copyright 2017 Dbvisit Software Limited. All Rights Reserved V3, Oct 2017 Contents Executive Summary...

More information

Architecting a Hybrid Database Strategy with Microsoft SQL Server and the VMware Cloud Provider Program

Architecting a Hybrid Database Strategy with Microsoft SQL Server and the VMware Cloud Provider Program VMware vcloud Architecture Toolkit for Service Providers Architecting a Hybrid Database Strategy with Microsoft SQL Server and the VMware Cloud Provider Program Version 2.9 January 2018 Martin Hosken 2018

More information

Experiences in Clustering CIFS for IBM Scale Out Network Attached Storage (SONAS)

Experiences in Clustering CIFS for IBM Scale Out Network Attached Storage (SONAS) Experiences in Clustering CIFS for IBM Scale Out Network Attached Storage (SONAS) Dr. Jens-Peter Akelbein Mathias Dietz, Christian Ambach IBM Germany R&D 2011 Storage Developer Conference. Insert Your

More information

Understanding high availability with WebSphere MQ

Understanding high availability with WebSphere MQ Mark Hiscock Software Engineer IBM Hursley Park Lab United Kingdom Simon Gormley Software Engineer IBM Hursley Park Lab United Kingdom May 11, 2005 Copyright International Business Machines Corporation

More information

ECE Engineering Robust Server Software. Spring 2018

ECE Engineering Robust Server Software. Spring 2018 ECE590-02 Engineering Robust Server Software Spring 2018 Business Continuity: High Availability Tyler Bletsch Duke University Includes material adapted from the course Information Storage and Management

More information

Hands-On Wide Area Storage & Network Design WAN: Design - Deployment - Performance - Troubleshooting

Hands-On Wide Area Storage & Network Design WAN: Design - Deployment - Performance - Troubleshooting Hands-On WAN: Design - Deployment - Performance - Troubleshooting Course Description This highly intense, vendor neutral, Hands-On 5-day course provides an in depth exploration of Wide Area Networking

More information

A GPFS Primer October 2005

A GPFS Primer October 2005 A Primer October 2005 Overview This paper describes (General Parallel File System) Version 2, Release 3 for AIX 5L and Linux. It provides an overview of key concepts which should be understood by those

More information

Index. Peter A. Carter 2016 P.A. Carter, SQL Server AlwaysOn Revealed, DOI /

Index. Peter A. Carter 2016 P.A. Carter, SQL Server AlwaysOn Revealed, DOI / Index A Active node, 10 Advanced Encryption Standard (AES), 95 AlwaysOn administration Availability Group (see AlwaysOn Availability Groups) cluster maintenance, 149 Cluster Node Configuration page, 153

More information

CSE 444: Database Internals. Section 9: 2-Phase Commit and Replication

CSE 444: Database Internals. Section 9: 2-Phase Commit and Replication CSE 444: Database Internals Section 9: 2-Phase Commit and Replication 1 Today 2-Phase Commit Replication 2 Two-Phase Commit Protocol (2PC) One coordinator and many subordinates Phase 1: Prepare Phase 2:

More information

HUAWEI OceanStor VIS6600T Product Presales Training

HUAWEI OceanStor VIS6600T Product Presales Training HUAWEI OceanStor VIS6600T Product Presales Training Contents 1 2 Market Overview and Product Positioning Highlights 3 Product Comparison 4 5 Success Stories Ordering Guide 6 How to Obtain Resources 2 Market

More information

Veritas Storage Foundation and High Availability Solutions Microsoft Clustering Solutions Guide for Microsoft SQL 2008

Veritas Storage Foundation and High Availability Solutions Microsoft Clustering Solutions Guide for Microsoft SQL 2008 Veritas Storage Foundation and High Availability Solutions Microsoft Clustering Solutions Guide for Microsoft SQL 2008 Windows Server 2003 Windows Server 2008 5.1 Application Pack 1 Veritas Storage Foundation

More information

CIT 668: System Architecture

CIT 668: System Architecture CIT 668: System Architecture Availability Topics 1. What is availability? 2. Measuring Availability 3. Failover 4. Failover Configurations 5. Linux HA Availability Availability is the ratio of the time

More information

IBM. Combining DB2 HADR with Q Replication. IBM DB2 for Linux, UNIX, and Windows. Rich Briddell Replication Center of Competency.

IBM. Combining DB2 HADR with Q Replication. IBM DB2 for Linux, UNIX, and Windows. Rich Briddell Replication Center of Competency. IBM IBM DB2 for Linux, UNIX, and Windows Combining DB2 HADR with Q Replication November 2011 Rich Briddell Replication Center of Competency 2 Table of contents Combining DB2 HADR with Q Replication...1

More information

Data Center Applications and MRV Solutions

Data Center Applications and MRV Solutions Data Center Applications and MRV Solutions Introduction For more than 25 years MRV has supplied the optical transport needs of customers around the globe. Our solutions are powering access networks for

More information

Arista 7500E DWDM Solution and Use Cases

Arista 7500E DWDM Solution and Use Cases ARISTA WHITE PAPER Arista DWDM Solution and Use Cases The introduction of the Arista 7500E Series DWDM solution expands the capabilities of the Arista 7000 Series with a new, high-density, high-performance,

More information