Nexus 1000v ERSPAN. - Original version

Size: px
Start display at page:

Download "Nexus 1000v ERSPAN. - Original version"

Transcription

1 Document Number Based on Template Created By EDCS-XXXXXX EDCS-XXXX Rev X Matthew Wronkowski mwronkow@cisco.com Nexus 1000v ERSPAN This document describes the configuration for ERSPAN sessions created on Nexus 1000v and terminated on N7k or 6500 devices. Please let me know if your topology is not covered by the examples in this document. Modification History Rev. Date Originator Release Comment /6/11 Matthew Wronkowski - Original version Table of Contents Nexus 1000v ERSPAN...1 Limitations...2 Topology...2 Nexus 1000v configuration...2 Nexus 7000 configuration...3 N1k ERSPAN to Catalyst Verification of ERSPAN...4 References:...5

2 Limitations N7k only supports 1 source IP per ERSPAN-DESTINATION. This means each ESX host needs a separate monitor session. Due to this limitation this is not a scalable solution for ongoing host monitoring. A scalable solution would be NetFlow with NAM. Topology Testing was completed under Nexus 1000v SV1(4a) and Nexus (4). Nexus 1000v configuration ERSPAN requires a vmkernel interface which is used as the GRE tunnel source. This vmkernel can be the same as the management vmk or it can be a dedicated interface. The port-profile capability l3control command indicates this interface will be used for Layer 3 communication. Create a new vmkernel and port-profile or add the capability command to an existing port-profile. Note this command cannot be removed from the port-profile while it is assigned to vethernet interfaces. Best practice would be to define a port-profile specifically for monitor sessions. The monitor session only requires the source traffic type and a destination IP configured. All other parameters are optional. The source can be an interface, port-channel, or vlan. The destination IP is the address of the target device. For Nexus 7000 or 6500 this is typically an SVI(interface vlan) and not the supervisor management address. Although the IP addresses used in the examples reside in the same subnet, this is not required. If a destination device will be receiving traffic from multiple sources it may be necessary to configure an ERSPAN-ID. This configuration is the same regardless of the ERSPAN destination device. Remember to the monitor session.

3 # VSM configuration port-profile type vethernet ERSPAN_SC capability l3control vmware port-group switchport mode access switchport access vlan 119 system vlan 119 description ESX vmk state enabled monitor session 2 type erspan-source source vlan 119 rx destination ip <- NAM/N7k/6500 IP ip ttl 64 ip prec 0 ip dscp 0 mtu 1500 header-type 2 Nexus 7000 configuration Begin by defining a target IP for the ERSPAN. This can be any IP address reachable by the ESX vmkernel interface in port-profile ERSPAN_SC. Next create an ERSPAN-DESTINATION monitor session. The source IP will be the vmkernel in the ERSPAN_SC port-profile. One limitation of N7k is only a single source IP per monitor session is allowed. Finally configure the destination of the ERSPAN. In this example we send traffic to a physical interface with a probe attached. interface Vlan119 ip address /24 <- Termination of ERSPAN tunnel interface Ethernet2/1 description incoming GRE tunnel switchport switchport mode trunk interface Ethernet2/3 description Monitor - connect to PC switchport switchport monitor spanning-tree port type edge trunk

4 monitor session 1 type erspan-destination description ERSPAN from N1k-VEM <- Optional SPAN-ID vrf default source ip <- ESX host vmk destination interface Ethernet2/3 N1k ERSPAN to Catalyst 6500 Begin by defining a target IP for the ERSPAN. This can be any IP address reachable by the ESX vmkernel interface in port-profile ERSPAN_SC. Next create an ERSPAN-DESTINATION monitor session. The source IP will be the SVI interface on the This may not be intuitive that SVI IP is used instead of the ESX vmk. Essentially we are telling the 6500 to listen on the SVI for incoming ERSPAN sessions. interface Vlan119 ip address /24 <- Termination of ERSPAN tunnel monitor session 1 type erspan-destination description ERSPAN from N1k-VEM destination interface Gi2/3 source <- Optional SPAN-ID ip address < SVI Verification of ERSPAN SV14# show monitor session 2 session type : erspan-source state : up source intf : rx : source VLANs : rx : 119 source port-profile : rx : filter VLANs : filter not specified destination IP : ERSPAN ID : 111 ERSPAN TTL : 64

5 ERSPAN IP Prec. : 0 ERSPAN DSCP : 0 ERSPAN MTU : 1500 ERSPAN Header Type: 2 SV14# module vem 5 execute vemcmd show span VEM SOURCE IP: HW SSN ID ERSPAN ID HDR VER DST LTL/IP SV14# show monitor internal info session 2 SV14# show monitor internal event-history session 2 References: Configuring Local SPAN and ERSPAN 6500: Configuring ERSPAN

Implementing the ERSPAN Analytics Feature on Cisco Nexus 6000 Series and 5600 Platform Switches

Implementing the ERSPAN Analytics Feature on Cisco Nexus 6000 Series and 5600 Platform Switches White Paper Implementing the ERSPAN Analytics Feature on Cisco Nexus 6000 Series and 5600 Platform Switches White Paper October 2014 2014 Cisco and/or its affiliates. All rights reserved. This document

More information

Configuring System Port Profiles

Configuring System Port Profiles 4 CHAPTER This chapter describes system port profiles and how to configure them. This chapter includes the following sections: Information About System Port Profiles, page 4-1 Guidelines and Limitations

More information

Nexus 1000v Port-Channel Best Practices

Nexus 1000v Port-Channel Best Practices Document Number Based on Template Created By EDCS-XXXXXX EDCS-XXXX Rev X Matthew mwronkow@cisco.com Nexus 1000v Port-Channel Best Practices The Nexus 1000v requires port-channels for port-profiles containing

More information

Configuring Local SPAN and ERSPAN

Configuring Local SPAN and ERSPAN This chapter contains the following sections: Information About ERSPAN, page 1 Licensing Requirements for ERSPAN, page 5 Prerequisites for ERSPAN, page 5 Guidelines and Limitations for ERSPAN, page 5 Guidelines

More information

Configuring NetFlow. Information About NetFlow. What is a Flow. This chapter contains the following sections:

Configuring NetFlow. Information About NetFlow. What is a Flow. This chapter contains the following sections: This chapter contains the following sections: Information About NetFlow, page 1 Guidelines and Limitations for NetFlow, page 9 Default Settings for NetFlow, page 10 Enabling the NetFlow Feature, page 11

More information

Send document comments to name List name. The range of valid values is 1 to 64.

Send document comments to name List name. The range of valid values is 1 to 64. This chapter describes the Cisco Nexus 1000V commands that begin with the letter M. mac access-list To create a MAC ACL, use the mac access-list command. To remove the MAC ACL, use the no form of this

More information

Configuring Virtual Ethernet Interfaces

Configuring Virtual Ethernet Interfaces CHAPTER 4 This chapter describes how to configure virtual Ethernet (vethernet or veth) interfaces. This chapter includes the following sections: Information About vethernet Interfaces, page 4-1 Guidelines

More information

Cisco HyperFlex Systems

Cisco HyperFlex Systems White Paper Cisco HyperFlex Systems Converting to Cisco Nexus 1000V Distributed Switches for Cisco HyperFlex Virtual Machine Guest and VMware vmotion Networks Author: Hui Chen October 2016 2016 Cisco and/or

More information

Chapter 5: Inter-VLAN Routing. Routing & Switching

Chapter 5: Inter-VLAN Routing. Routing & Switching Chapter 5: Inter-VLAN Routing Routing & Switching What is Inter-VLAN routing? Layer 2 switches cannot forward traffic between VLANs without the assistance of a router. Inter-VLAN routing is a process for

More information

Configuring an IP ACL

Configuring an IP ACL 9 CHAPTER This chapter describes how to configure IP access control lists (ACLs). This chapter includes the following sections: Information About ACLs, page 9-1 Prerequisites for IP ACLs, page 9-5 Guidelines

More information

Send document comments to Information About Layer 2 Ethernet Switching

Send document comments to Information About Layer 2 Ethernet Switching CHAPTER 8 This chapter describes how to identify and resolve problems that relate to Layer 2 switching. This chapter includes the following sections: Information About Layer 2 Ethernet Switching, page

More information

Cisco Virtual Security Gateway Deployment Guide VSG 1.4

Cisco Virtual Security Gateway Deployment Guide VSG 1.4 Deployment Guide Cisco Virtual Security Gateway Deployment Guide VSG 1.4 Deployment Guide 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 33

More information

Verified Scalability Limits

Verified Scalability Limits This chapter describes the Cisco NX-OS configuration limits for the Cisco Nexus 9000 Series switches. Introduction, page 1, page 1 Deployment Case Studies, page Introduction The values provided in this

More information

Security and Virtualization in the Data Center. BRKSEC Cisco Systems, Inc. All rights reserved. Cisco Public

Security and Virtualization in the Data Center. BRKSEC Cisco Systems, Inc. All rights reserved. Cisco Public Security and Virtualization in the Data Center 1 What We ll Cover Areas of Interest Security for Data Center Layers Device Virtualization & Security Services Security Considerations for Server Virtualization

More information

Implementing Inter-VLAN Routing. 2003, Cisco Systems, Inc. All rights reserved. 2-1

Implementing Inter-VLAN Routing. 2003, Cisco Systems, Inc. All rights reserved. 2-1 Implementing Inter-VLAN Routing 2003, Cisco Systems, Inc. All rights reserved. 2-1 Internetwork Communications C:>ping 172.16.30.100 Can two hosts on different subnets communicate without a router? No

More information

Table of Contents HOL-PRT-1305

Table of Contents HOL-PRT-1305 Table of Contents Lab Overview... 2 - Abstract... 3 Overview of Cisco Nexus 1000V series Enhanced-VXLAN... 5 vcloud Director Networking and Cisco Nexus 1000V... 7 Solution Architecture... 9 Verify Cisco

More information

Verified Scalability Limits

Verified Scalability Limits This chapter describes the Cisco NX-OS configuration limits for the Cisco Nexus 9000 Series switches. Introduction, page 1, page 1 Deployment Case Studies, page 6 Introduction The values provided in this

More information

Configure RSPAN with VMware

Configure RSPAN with VMware Configure RSPAN with VMware Published: 2019-01-07 The Remote Switched Port Analyzer (RSPAN) enables you to monitor traffic on one switch through a device on another switch and then send the monitored traffic

More information

VSB Backup and Recovery

VSB Backup and Recovery CHAPTER 6 This chapter describes how to backup and recover a VSB, and includes the following sections: Information About, page 6-1 Guidelines and Limitations, page 6-1 Configuring VSB Backup and Restoration,

More information

Implementing Inter-VLAN Routing

Implementing Inter-VLAN Routing Internetwork Communications C:>ping 72.6.30.00 Implementing Inter-VLN Routing Can two hosts on different subnets communicate without a router? No What would happen if a host tried to ping another host?

More information

Cisco Prime Network Analysis Module (Cisco Prime NAM) for Nexus 1110 Installation and Configuration Guide

Cisco Prime Network Analysis Module (Cisco Prime NAM) for Nexus 1110 Installation and Configuration Guide Cisco Prime Network Analysis Module (Cisco Prime NAM) for Nexus 1110 Installation and Configuration Guide Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com

More information

Cisco Nexus 1000V System Management Configuration Guide, Release 4.2(1)SV2(2.2)

Cisco Nexus 1000V System Management Configuration Guide, Release 4.2(1)SV2(2.2) Cisco Nexus 1000V System Management Configuration Guide, Release 4.2(1)SV2(2.2) First Published: January 30, 2014 Last Modified: October 20, 2014 Americas Headquarters Cisco Systems, Inc. 170 West Tasman

More information

Configuring Web Cache Services By Using WCCP

Configuring Web Cache Services By Using WCCP CHAPTER 44 Configuring Web Cache Services By Using WCCP This chapter describes how to configure your Catalyst 3560 switch to redirect traffic to wide-area application engines (such as the Cisco Cache Engine

More information

This chapter describes how to configure the NetFlow feature on Cisco NX-OS devices.

This chapter describes how to configure the NetFlow feature on Cisco NX-OS devices. This chapter describes how to configure the NetFlow feature on Cisco NX-OS devices. Finding Feature Information, page 1 NetFlow, page 2 Licensing Requirements for NetFlow, page 6 Prerequisites for NetFlow,

More information

Troubleshooting Licensing Issues

Troubleshooting Licensing Issues CHAPTER 4 This chapter describes how to identify and resolve problems related to firewall licensing on the Virtual Supervisor Module (VSM). This chapter includes the following sections: Information about

More information

Configuring Traffic Mirroring

Configuring Traffic Mirroring This module describes the configuration of the traffic mirroring feature. Traffic mirroring is sometimes called port mirroring, or switched port analyzer (SPAN). Feature History for Traffic Mirroring Release

More information

Hypervisors networking: best practices for interconnecting with Cisco switches

Hypervisors networking: best practices for interconnecting with Cisco switches Hypervisors networking: best practices for interconnecting with Cisco switches Ramses Smeyers Customer Support Engineer Agenda What is this session about? Networking virtualization concepts Hypervisor

More information

Cisco Nexus 1000V Installation and Upgrade Guide, Release 5.2(1)SV3(1.4)

Cisco Nexus 1000V Installation and Upgrade Guide, Release 5.2(1)SV3(1.4) Cisco Nexus 1000V Installation and Upgrade Guide, Release 5.2(1)SV3(1.4) First Published: April 17, 2015 Last Modified: August 27, 2015 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San

More information

Configuring NetFlow. About NetFlow. This chapter describes how to configure the NetFlow feature on Cisco NX-OS devices.

Configuring NetFlow. About NetFlow. This chapter describes how to configure the NetFlow feature on Cisco NX-OS devices. This chapter describes how to configure the NetFlow feature on Cisco NX-OS devices. About NetFlow, page 1 Licensing Requirements for NetFlow, page 4 Prerequisites for NetFlow, page 4 Guidelines and Limitations

More information

LAN Switching Configuration Guide

LAN Switching Configuration Guide Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 THE SPECIFICATIONS AND INFORMATION

More information

Verified Scalability Limits

Verified Scalability Limits This chapter describes the Cisco NX-OS configuration limits for the Cisco Nexus 316Q switch. Introduction, page 1 (Unidimensional), page 1 Introduction The values provided in this guide should not be interpreted

More information

Virtual Security Gateway Overview

Virtual Security Gateway Overview This chapter contains the following sections: Information About the Cisco Virtual Security Gateway, page 1 Cisco Virtual Security Gateway Configuration for the Network, page 10 Feature History for Overview,

More information

ANALYSIS OF VIRTUAL NETWORKS IN DATA CENTERS.

ANALYSIS OF VIRTUAL NETWORKS IN DATA CENTERS. ANALYSIS OF VIRTUAL NETWORKS IN DATA CENTERS. Ionka Gancheva, PhD student 45 Abstract: The article contains an analysis of virtual networks and technologies that are used at data centers nowadays. Many

More information

Configuring Traffic Mirroring

Configuring Traffic Mirroring This module describes the configuration of the traffic mirroring feature. Traffic mirroring is sometimes called port mirroring, or switched port analyzer (SPAN). Feature History for Traffic Mirroring Release

More information

Configure RSPAN with VMware

Configure RSPAN with VMware Configure RSPAN with VMware Published: 2018-04-19 The Remote Switched Port Analyzer (RSPAN) enables you to monitor traffic on one switch through a device on another switch and then send the monitored traffic

More information

Understanding PVLANs in UCS

Understanding PVLANs in UCS Understanding PVLANs in UCS Introduction This document explains the PVLAN support in UCS - a feature which is introduced in the Balboa (1.4) release. This document explains the feature, the caveats and

More information

Configuring Voice VLAN

Configuring Voice VLAN CHAPTER 15 This chapter describes how to configure the voice VLAN feature on the Catalyst 3750 switch. Unless otherwise noted, the term switch refers to a standalone switch and a switch stack. Voice VLAN

More information

Migrating Hosts to the Cisco Nexus 1000V Using Cisco Virtual Switch Update Manager, page 3

Migrating Hosts to the Cisco Nexus 1000V Using Cisco Virtual Switch Update Manager, page 3 Migrating Hosts to Cisco Nexus 1000V Using Cisco Virtual Switch Update Manager This chapter contains the following sections: Information About Migrating Hosts to the Cisco Nexus 1000V Switch Using Cisco

More information

Verifying the Port Profile Configuration

Verifying the Port Profile Configuration CHAPTER 7 This chapter describes the commands used to verify port profile configurations and includes the following sections:, page 7-1 Feature History for Port Profile Verification, page 7-5 You can use

More information

Configuring VLANs. Understanding VLANs CHAPTER

Configuring VLANs. Understanding VLANs CHAPTER CHAPTER 11 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on the Cisco ME 3400 Ethernet Access switch. It includes information

More information

Configuring SPAN. About SPAN. SPAN Sources

Configuring SPAN. About SPAN. SPAN Sources This chapter describes how to configure an Ethernet switched port analyzer (SPAN) to analyze traffic between ports on Cisco NX-OS devices. This chapter contains the following sections: About SPAN, page

More information

On the Cisco Nexus 5548 Switch, Fibre Channel ports and VSAN ports cannot be configured as ingress source ports in a SPAN session.

On the Cisco Nexus 5548 Switch, Fibre Channel ports and VSAN ports cannot be configured as ingress source ports in a SPAN session. This chapter includes the following sections:, page 1 SPAN Sources The Switched Port Analyzer (SPAN) feature (sometimes called port mirroring or port monitoring) selects network traffic for analysis by

More information

UCS C Series Rack Servers VIC Connectivity Options

UCS C Series Rack Servers VIC Connectivity Options UCS C Series Rack Servers VIC Connectivity Options Document ID: 117637 Contributed by Shankar Prasath, Cisco TAC Engineer. Apr 25, 2014 Contents Introduction Prerequisites Requirements Components Used

More information

Configuring Port Channels

Configuring Port Channels This chapter contains the following sections: Information About Port Channels, page 1, page 11 Verifying Port Channel Configuration, page 19 Triggering the Port Channel Membership Consistency Checker,

More information

Implementing Inter-VLAN Routing

Implementing Inter-VLAN Routing Internetwork Communications C:>ping 172.16.30.100 Implementing Inter-VLAN Routing Can two hosts on different subnets communicate without a router? No What would happen if a host tried to ping another host?

More information

Configuring SPAN. Finding Feature Information. About SPAN. SPAN Sources

Configuring SPAN. Finding Feature Information. About SPAN. SPAN Sources This chapter describes how to configure an Ethernet switched port analyzer (SPAN) to analyze traffic between ports on Cisco NX-OS devices. Finding Feature Information, on page 1 About SPAN, on page 1 Licensing

More information

Deploy the ExtraHop Discover Appliance with VMware

Deploy the ExtraHop Discover Appliance with VMware Deploy the ExtraHop Discover Appliance with VMware Published: 2018-07-16 The ExtraHop virtual appliance can help you to monitor the performance of your applications across internal networks, the public

More information

CCIE Data Center Written Exam ( ) version 1.0

CCIE Data Center Written Exam ( ) version 1.0 CCIE Data Center Written Exam (350-080) version 1.0 Exam Description: The Cisco CCIE Data Center Written Exam (350-080) version 1.0 is a 2-hour test with 80 110 questions that will validate that a data

More information

Configuring NetFlow. NetFlow Overview

Configuring NetFlow. NetFlow Overview NetFlow Overview NetFlow identifies packet flows for ingress IP packets and provides statistics based on these packet flows. NetFlow does not require any change to either the packets themselves or to any

More information

Configuring SPAN. Configuring SPAN. SPAN Sources. This chapter includes the following sections: Configuring SPAN, page 1

Configuring SPAN. Configuring SPAN. SPAN Sources. This chapter includes the following sections: Configuring SPAN, page 1 This chapter includes the following sections:, page 1 SPAN Sources The Switched Port Analyzer (SPAN) feature (sometimes called port mirroring or port monitoring) selects network traffic for analysis by

More information

Cisco Nexus 1000V Switch for Microsoft Hyper-V

Cisco Nexus 1000V Switch for Microsoft Hyper-V Q&A Cisco Nexus 1000V Switch for Microsoft Hyper-V Overview Q. What are Cisco Nexus 1000V Switches? A. Cisco Nexus 1000V Switches provide a comprehensive and extensible architectural platform for virtual

More information

Configuring SPAN and RSPAN

Configuring SPAN and RSPAN 34 CHAPTER This chapter describes how to configure the Switched Port Analyzer (SPAN) and Remote SPAN (RSPAN) on the Catalyst 4500 series switches. SPAN selects network traffic for analysis by a network

More information

Installing and Configuring VXLAN Gateway

Installing and Configuring VXLAN Gateway Installing and Configuring VXLAN Gateway This chapter contains the following sections: Information About the VXLAN Gateway Deployment, page 1 Guidelines and Limitations, page 2 Configuring VSMs, page 3

More information

Cisco Nexus 1000V Software Upgrade Guide, Release 4.0(4)SV1(3d)

Cisco Nexus 1000V Software Upgrade Guide, Release 4.0(4)SV1(3d) Cisco Nexus 1000V Software Upgrade Guide, Release 4.0(4)SV1(3d) Revised: May 21, 2011 This document describes how to upgrade the Cisco Nexus 1000V software on a Virtual Supervisor Module (VSM) virtual

More information

Enterprise. Nexus 1000V. L2/L3 Fabric WAN/PE. Customer VRF. MPLS Backbone. Service Provider Data Center-1 Customer VRF WAN/PE OTV OTV.

Enterprise. Nexus 1000V. L2/L3 Fabric WAN/PE. Customer VRF. MPLS Backbone. Service Provider Data Center-1 Customer VRF WAN/PE OTV OTV. 2 CHAPTER Cisco's Disaster Recovery as a Service (DRaaS) architecture supports virtual data centers that consist of a collection of geographically-dispersed data center locations. Since data centers are

More information

Cisco Nexus 1000V for VMware vsphere VDP Configuration Guide, Release 5.x

Cisco Nexus 1000V for VMware vsphere VDP Configuration Guide, Release 5.x Cisco Nexus 1000V for VMware vsphere VDP Configuration Guide, Release 5.x First Published: August 12, 2014 Last Modified: November 10, 2014 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive

More information

Cisco Nexus 1000V Getting Started Guide, Release 4.2(1) SV1(4a)

Cisco Nexus 1000V Getting Started Guide, Release 4.2(1) SV1(4a) Cisco Nexus 1000V Getting Started Guide, Release 4.2(1) SV1(4a) October 18, 2011 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408

More information

Configuring SPAN and RSPAN

Configuring SPAN and RSPAN 41 CHAPTER This chapter describes how to configure the Switched Port Analyzer (SPAN) and Remote SPAN (RSPAN) on the Catalyst 4500 series switches. SPAN selects network traffic for analysis by a network

More information

Configuring Devices for Flow Collection

Configuring Devices for Flow Collection This PDF is no longer being maintained. See the SolarWinds Success Center for more information. SolarWinds Technical Reference Configuring Devices for Flow Collection Introduction... 3 Cisco... 3 Cisco

More information

Configuring VLANs. Understanding VLANs CHAPTER

Configuring VLANs. Understanding VLANs CHAPTER CHAPTER 14 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on the Catalyst 3750 switch. It includes information about VLAN

More information

The following steps should be used when configuring a VLAN on the EdgeXOS platform:

The following steps should be used when configuring a VLAN on the EdgeXOS platform: EdgeXOS VLANs VLAN Overview This document provides an overview of what a VLAN is and how it is configured on the EdgeXOS platform. Use the step-by-step guide below to configure a VLAN on the Edge appliance

More information

WCCP Network Integration with Cisco Catalyst 6500: Best Practice Recommendations for Successful Deployments

WCCP Network Integration with Cisco Catalyst 6500: Best Practice Recommendations for Successful Deployments WCCP Network Integration with Cisco Catalyst 6500: Best Practice Recommendations for Successful Deployments What You Will Learn This document is intended for network engineers deploying the Cisco Catalyst

More information

Cisco Nexus 1000V InterCloud

Cisco Nexus 1000V InterCloud Deployment Guide Cisco Nexus 1000V InterCloud Deployment Guide (Draft) June 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 49 Contents

More information

VLAN Configuration. Understanding VLANs CHAPTER

VLAN Configuration. Understanding VLANs CHAPTER CHAPTER 11 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on the CGR 2010 ESM. It includes information about VLAN membership

More information

Troubleshooting Licensing Issues

Troubleshooting Licensing Issues 4 CHAPTER This chapter describes how to troubleshoot issues that are related to firewall licensing on the Virtual Supervisor Module (VSM). This chapter includes the following sections: Information About

More information

Virtualized Access Layer. Petr Grygárek

Virtualized Access Layer. Petr Grygárek Virtualized Access Layer Petr Grygárek Goals Integrate physical network with virtualized access layer switches Hypervisor vswitch Handle logical network connection of multiple (migrating) OS images hosted

More information

Network Virtualization

Network Virtualization Network Virtualization Petr Grygárek 1 Traditional Virtualization Techniques Network Virtualization Implementation of separate logical network environments (Virtual Networks, VNs) for multiple groups on

More information

Configuring Virtual Service Blades

Configuring Virtual Service Blades CHAPTER 4 This chapter describes how to create and configure virtual service blades and includes the following sections: Information About Virtual Service Blades, page 4-1 Guidelines and Limitations, page

More information

Configuring Q-in-Q VLAN Tunnels

Configuring Q-in-Q VLAN Tunnels Information About Q-in-Q Tunnels, page 1 Licensing Requirements for Interfaces, page 7 Guidelines and Limitations, page 7 Configuring Q-in-Q Tunnels and Layer 2 Protocol Tunneling, page 8 Configuring Q-in-Q

More information

Cisco Nexus 1000V System Management Configuration Guide, Release 4.2(1)SV1(5.1)

Cisco Nexus 1000V System Management Configuration Guide, Release 4.2(1)SV1(5.1) Cisco Nexus 1000V System Management Configuration Guide, Release 4.2(1)SV1(5.1) January 14, 2014 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com

More information

Configuring NetFlow. NetFlow Overview

Configuring NetFlow. NetFlow Overview NetFlow identifies packet flows for ingress IP packets and provides statistics based on these packet flows. NetFlow does not require any change to either the packets themselves or to any networking device.

More information

Configuring VLANs. Understanding VLANs CHAPTER

Configuring VLANs. Understanding VLANs CHAPTER 7 CHAPTER This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on the Cisco MWR 2941 router. It includes information about VLAN

More information

Configuring VLANs. Understanding VLANs CHAPTER

Configuring VLANs. Understanding VLANs CHAPTER CHAPTER 12 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on the switch. It includes information about VLAN membership

More information

Configuring Layer 3 Interfaces

Configuring Layer 3 Interfaces This chapter contains the following sections: Information About Layer 3 Interfaces, page 1 Licensing Requirements for Layer 3 Interfaces, page 4 Guidelines and Limitations for Layer 3 Interfaces, page

More information

Nexus 1000V in Context of SDN. Martin Divis, CSE,

Nexus 1000V in Context of SDN. Martin Divis, CSE, Nexus 1000V in Context of SDN Martin Divis, CSE, mdivis@cisco.com Why Cisco Nexus 1000V Losing the Edge Server Admin Host Host Host Host Server Admin manages virtual switching! vswitch vswitch vswitch

More information

Inside the Nexus 1000V Virtual Switch

Inside the Nexus 1000V Virtual Switch Inside the Nexus 1000V Virtual Switch BRKVIR-2012 www.ciscolivevirtual.com Agenda Nexus 1000V Why Nexus 1000V? VSMs, VEMs, and Port Profiles VMotion Physical Host Connectivity Port Channels and Upstream

More information

Architecting Scalable Clouds using VXLAN and Nexus 1000V

Architecting Scalable Clouds using VXLAN and Nexus 1000V Architecting Scalable Clouds using VXLAN and Nexus 1000V Lawrence Kreeger Principal Engineer Agenda Session Is Broken Into 3 Main Parts Part 1: VXLAN Overview What is a VXLAN? Why VXLANs? What is VMware

More information

monitor event-trace (EXEC)

monitor event-trace (EXEC) monitor event-trace (EXEC) monitor event-trace (EXEC) To monitor and control the event trace function for a specified Cisco IOS software subsystem component, use the monitor event-trace command in privileged

More information

Configuring VLANs. Understanding VLANs CHAPTER

Configuring VLANs. Understanding VLANs CHAPTER CHAPTER 9 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094). It includes information about VLAN membership modes, VLAN configuration

More information

Configuring IP Tunnels

Configuring IP Tunnels This chapter describes how to configure IP tunnels using Generic Route Encapsulation (GRE) on Cisco NX-OS devices. Information About IP Tunnels, page 1 Licensing Requirements for IP Tunnels, page 3 Prerequisites

More information

Configuring Cache Services Using the Web Cache Communication Protocol

Configuring Cache Services Using the Web Cache Communication Protocol Configuring Cache Services Using the Web Cache Communication Protocol Finding Feature Information, page 1 Prerequisites for WCCP, page 1 Restrictions for WCCP, page 2 Information About WCCP, page 3 How

More information

Configuring SPAN. Understanding SPAN CHAPTER. This chapter describes how to configure Switched Port Analyzer (SPAN) and on the Catalyst 2960 switch.

Configuring SPAN. Understanding SPAN CHAPTER. This chapter describes how to configure Switched Port Analyzer (SPAN) and on the Catalyst 2960 switch. CHAPTER 23 This chapter describes how to configure Switched Port Analyzer (SPAN) and on the Catalyst 2960 switch. Note For complete syntax and usage information for the commands used in this chapter, see

More information

Installing and Configuring Licenses

Installing and Configuring Licenses This chapter contains the following sections: Information About Installing and Upgrading s, page 1 Licensing Guidelines and Limitations, page 2 Default Configuration Settings, page 3 Obtaining and Installing

More information

Configuring the Software Using the GUI

Configuring the Software Using the GUI CHAPTER 3 This chapter describes how to use the GUI application to complete the Cisco Nexus 1000V configuration, and includes the following sections. GUI Software Configuration Process, page 3-2 Guidelines

More information

What s New in VMware vsphere 4: Virtual Networking W H I T E P A P E R

What s New in VMware vsphere 4: Virtual Networking W H I T E P A P E R What s New in ware vsphere 4: W H I T E P A P E R What s New in ware vsphere 4: Table of Contents Introduction................................................................ 3 ware vnetwork: Summary of

More information

Configuring NetFlow. Information About NetFlow. Send document comments to CHAPTER

Configuring NetFlow. Information About NetFlow. Send document comments to CHAPTER CHAPTER 11 Use this chapter to configure NetFlow to characterize IP traffic based on its source, traffic destination, timing, and application information, giving visibility into traffic transiting the

More information

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme NET1350BUR Deploying NSX on a Cisco Infrastructure Jacob Rapp jrapp@vmware.com Paul A. Mancuso pmancuso@vmware.com #VMworld #NET1350BUR Disclaimer This presentation may contain product features that are

More information

What s New in VMware vsphere 4:

What s New in VMware vsphere 4: Written and Provided by Expert Reference Series of White Papers What s New in ware vsphere 4: Virtual Networking 1-800-COURSES www.globalknowledge.com What s New in ware vsphere 4: Virtual Networking Introduction

More information

Cisco Introducing Cisco Data Center Networking - DCICN. Download Full version :

Cisco Introducing Cisco Data Center Networking - DCICN. Download Full version : Cisco 640-911 Introducing Cisco Data Center Networking - DCICN Download Full version : http://killexams.com/pass4sure/exam-detail/640-911 There is a large amount of traffic inside a network segment with

More information

Using the REST API Plug-in

Using the REST API Plug-in This chapter contains the following sections: Supported Response Formats, page 1 Supported HTTP Methods, page 2 Cisco Nexus 1000V REST API Resources, page 3 Executing CLI via REST, page 12 Saving Resource

More information

Configuring MPLS and EoMPLS

Configuring MPLS and EoMPLS 37 CHAPTER This chapter describes how to configure multiprotocol label switching (MPLS) and Ethernet over MPLS (EoMPLS) on the Catalyst 3750 Metro switch. MPLS is a packet-switching technology that integrates

More information

W H I T E P A P E R. What s New in VMware vsphere 4: Virtual Networking

W H I T E P A P E R. What s New in VMware vsphere 4: Virtual Networking W H I T E P A P E R What s New in ware vsphere 4: Virtual Networking WARE WHITE PAPER Introduction................................................................... 3 ware vnetwork: Summary of Enhancements..................................

More information

Configuring Virtual Port Channels

Configuring Virtual Port Channels This chapter contains the following sections: Information About vpcs vpc Overview Information About vpcs, on page 1 Guidelines and Limitations for vpcs, on page 11 Verifying the vpc Configuration, on page

More information

This guide presents the instructions and other information concerning the lab activities for this course.

This guide presents the instructions and other information concerning the lab activities for this course. DCICT Lab Guide 11/03/2013 Overview Outline This guide presents the instructions and other information concerning the lab activities for this course. This guide includes these activities: Activity 1-1:

More information

Cisco Nexus 1000V Series Switches

Cisco Nexus 1000V Series Switches Cisco Nexus 1000V Series Switches Product Overview Cisco Nexus 1000V Series Switches are virtual machine access switches that are an intelligent software switch implementation for VMware vsphere environments

More information

Configuring OpenFlow. Information About OpenFlow. This chapter contains the following sections:

Configuring OpenFlow. Information About OpenFlow. This chapter contains the following sections: This chapter contains the following sections: Information About OpenFlow, page 1 OpenFlow Limitations, page 2 Supported Interface Types, page 2 Unsupported Interface Types, page 2 Supported Interface Modes,

More information

UCS with VMware ESXi End to End Jumbo MTU Configuration Example

UCS with VMware ESXi End to End Jumbo MTU Configuration Example UCS with VMware ESXi End to End Jumbo MTU Configuration Example Document ID: 117601 Contributed by Vishal Mehta, Cisco TAC Engineer. Apr 09, 2014 Contents Introduction Prerequisites Requirements Components

More information

Configuring SPAN and RSPAN

Configuring SPAN and RSPAN 24 CHAPTER This chapter describes how to configure Switched Port Analyzer (SPAN) and Remote SPAN (RSPAN) on your Catalyst 2950 or Catalyst 2955 switch. Note For complete syntax and usage information for

More information

Cisco Nexus 1100 Series Virtual Services Appliances

Cisco Nexus 1100 Series Virtual Services Appliances Deployment Guide Cisco Nexus 1100 Series Virtual Services Appliances Deployment Guide Version 1.0 June 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.

More information

Network Services in Virtualized Data Center

Network Services in Virtualized Data Center Network Services in Virtualized Data Center Tomáš Michaeli Consulting Systems Engineer, DCV Central / Czech republic 21 Mar 2012 2011 Cisco and/or its affiliates. All rights reserved. Cisco Public 1 Almost

More information