UCS Networking Deep Dive. Neehal Dass - Customer Support Engineer
|
|
- Lee Robertson
- 6 years ago
- Views:
Transcription
1
2 UCS Networking Deep Dive Neehal Dass - Customer Support Engineer
3 Agenda Chassis Connectivity Server Connectivity Fabric Forwarding M-Series Q & A
4 Cisco Unified Computing System (UCS) Single Point of Management Logical Building Blocks Stateless Compute (Service Profiles)
5 UCS Components LAN MGMT SAN Fabric Interconnect UCS Chassis Heartbeat link (No Data)
6 UCS Components LAN MGMT SAN Fabric Interconnect UCS Chassis Heartbeat link (No Data) IO Module
7 UCS Components LAN MGMT SAN Fabric Interconnect 4 x 10G KR lanes to each half width blade slot. UCS Chassis IO Module Heartbeat link (No Data)
8 UCS Components Fabric Interconnect Cisco VIC IO Module Heartbeat link (No Data) UCS Blade
9 UCS Mini: 6324 Fabric Interconnect UCS B UCS 5108 Chassis Supports existing and future blades + IO Modules or 6296 Fabric Fabric Interconnects UCS Mini Fabric Interconnect UCS 5108 Chassis Supports existing and future blades
10 3 rd Generation Fabric Interconnect and IOM
11 UCS FI & IOM Models FI 6300 Series and IOM 2304 FI x 40GbE QSFP+ ports 2.56Tbps switching performance 1RU fixed form factor, two power supplies & four fans FI UP 24 x 40GbE QSFP+ & 16 x UP ports (1/10GbE or 4/8/16G FC) 2.43Tbps switching performance 1RU fixed form factor, two power supplies & four fans IOM x 40GbE server links & 4 x 40GbE QSFP+ uplinks 960Gbps switching performance Modular IOM for UCS 5108
12 FI 6300 Series Hardware Overview FI 6332 (Ethernet Only) FI UP (Unified) L1 & L2 High avail ports 26 x 40G QSFP+ * or 98 x 10G SFP+ ** 6 x 40G QSFP+ L1 & L2 High avail ports 16 x UP 16 x 1/10G SFP+ or 16 x 4/8/16G FC 18 x 40G QSFP+ Or 72 x 10G SFP+ * 6 x 40G QSFP Series (Rear View) * QSA module required on ports to provide 10G support ** Requires QSFP to 4xSFP breakout cable 4 x Fans 2 x Power Supplies Serial Ports
13 Chassis Connectivity
14 UCS Fabric Topologies Chassis Bandwidth Options 2208XP only 2x 1 Link 20 Gbps per Chassis 2x 2 Link 40 Gbps per Chassis 2x 4 Link 80 Gbps per Chassis 2x 8 Links 160 Gbps per Chassis 80 Gbps per Chassis (IOM-2304) 160 Gbps per Chassis (IOM-2304) 320 Gbps per Chassis (IOM-2304)
15 UCS 2200 IO Module (FEX) UCS-IOM-2204XP UCS-IOM-2208XP 40G to the Network 160G to the Hosts 2x10G Half width slot 4x10G Full width slot 80G to the Network 320G to the Hosts 4x10G Half width slot 8x10G Full width slot
16 UCS-IOM-2304 Interface NIF 4 x 40G QSFP Connects only to FI63xx HIF 32 Interfaces Supports 10G or 4 ports can be combined to a single 40G HIF
17 VN-TAG: Pre-Standard IEEE 802.1BR FEX architecture Switch FEX LAN Frame VNTAG Frame Application Payload TCP IP VN-TAG Ethernet VN-TAG Ethertype d p destination virtual interface l r ver source virtual interface
18 UCS IOM 220x Architecture Fabric Ports to FI Network Interfaces (NIFs) FLASH DRAM EEPROM Feature 2204-XP 2208-XP Chassis Management Controller Control IO CIMC Switch Woodside ASIC ASIC Woodside Woodside Fabric Ports (NIF) Host Ports (HIF) Chassis Signals Latency ~ 500ns ~ 500ns Internal backplane ports to blades Host Interfaces (HIFs)
19 IOM Fabric & Backplane Interfaces Backplane port to blade 1/3 UCSB-2-A# connect nxos UCSB-2-A(nxos)# show fex detail FEX: 1 Description: FEX0001 state: Online Extender Model: UCS-IOM-2204XP, Part No: pinning-mode: static Max-links: 1 Fabric interface state: Eth1/3 - Interface Up. State: Active Eth1/4 - Interface Up. State: Active Fex Port State Fabric Port Eth1/1/1 Down Eth1/3 Eth1/1/2 Down None Eth1/1/3 Up Eth1/4 Eth1/1/4 Down None Eth1/1/5 Up Eth1/3 Eth1/1/6 Up Eth1/3 Eth1/1/7 Up Eth1/4 Eth1/1/8 Down None Eth1/1/9 Up Eth1/3 Eth1/1/10 Down None Eth1/1/11 Up Eth1/4 Eth1/1/12 Up Eth1/4 Eth1/1/13 Up Eth1/3 Eth1/1/14 Down None Eth1/1/15 Up Eth1/4 Eth1/1/16 Down None Eth1/1/17 Up Eth1/4 FI ports IOM connects to Backplane to FI pinning 1G link to CIMC switch.
20 NIFs HIFs
21 NIFs HIFs
22 IOM Traffic Rate Monitoring Statistics from perspective of IOM!
23 UCS Mini: 6324 Fabric Interconnect UCS B UCS 5108 Chassis Supports existing and future blades + IO Modules or 6296 Fabric Fabric Interconnects UCS Mini Fabric Interconnect UCS 5108 Chassis Supports existing and future blades
24 UCS Mini Secondary Chassis A secondary chassis can be added to an existing UCS Mini Cluster This can be achieved by connected the secondary chassis through the Scalability Ports on the UCS Mini Fabric Interconnect The secondary chassis requires a UCS-2204 or a UCS-2208 IOM Only one secondary chassis can be connected FEX based Rack Server connectivity is not supported
25 UCS Mini Secondary Chassis
26 UCS Mini Secondary Chassis
27 Fabric Link Connectivity
28 Chassis Connectivity Policy
29 IO Module HIF to NIF Pinning 2208XP 1 Link NIF1 HIF1-4 HIF5-8 Slot 1 Slot 2 HIF1-4 HIF5-8 NIF1 HIF9-12 HIF13-16 HIF17-20 HIF21-24 HIF25-28 HIF29-32 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 HIF9-12 HIF13-16 HIF17-20 HIF21-24 HIF25-28 HIF29-32
30 IO Module HIF to NIF Pinning 2208XP 2 Links NIF1 HIF1-4 HIF5-8 Slot 1 Slot 2 HIF1-4 HIF5-8 NIF1 NIF2 HIF9-12 HIF13-16 HIF17-20 HIF21-24 HIF25-28 HIF29-32 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 HIF9-12 HIF13-16 HIF17-20 HIF21-24 HIF25-28 HIF29-32 NIF2
31 IO Module HIF to NIF Pinning 2208XP 4 Links NIF1 HIF1-4 HIF5-8 Slot 1 Slot 2 HIF1-4 HIF5-8 NIF1 NIF2 NIF3 NIF4 HIF9-12 HIF13-16 HIF17-20 HIF21-24 HIF25-28 HIF29-32 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 HIF9-12 HIF13-16 HIF17-20 HIF21-24 HIF25-28 HIF29-32 NIF2 NIF3 NIF4
32 IO Module HIF to NIF Pinning 2208XP 8 Links Slot 1 HIF1-4 HIF1-4 NIF1 HIF5-8 Slot 2 HIF5-8 NIF1 NIF2 NIF3 NIF4 HIF9-12 HIF13-16 Slot 3 Slot 4 HIF9-12 HIF13-16 NIF2 NIF3 NIF4 NIF5 Slot 5 NIF5 NIF6 NIF7 NIF8 HIF17-20 HIF21-24 HIF25-28 Slot 6 Slot 7 Slot 8 HIF17-20 HIF21-24 HIF25-28 NIF6 NIF7 NIF8 HIF29-32 HIF29-32
33 IOM Link Failure Scenario Link Failure HIF1-4 NIF1 HIF5-8 NIF2 NIF3 HIF9-12 NIF4 HIF13-16 HIF17-20 HIF21-24 HIF25-28 HIF29-32 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 HIF1-4 HIF5-8 HIF9-12 HIF13-16 HIF17-20 HIF21-24 HIF25-28 HIF29-32 NIF1 NIF2 NIF3 NIF4
34 IOM Link Failure Scenario HIF1-4 NIF1 HIF5-8 NIF2 NIF3 HIF9-12 NIF4 HIF13-16 HIF17-20 HIF21-24 HIF25-28 HIF29-32 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 HIF1-4 HIF5-8 HIF9-12 HIF13-16 HIF17-20 HIF21-24 HIF25-28 HIF29-32 NIF1 NIF2 NIF3 NIF4
35 IOM Link Failure Scenario NIF1 HIF1-4 HIF5-8 Slot 1 Slot 2 HIF1-4 HIF5-8 NIF1 NIF2 NIF3 HIF9-12 HIF13-16 HIF17-20 HIF21-24 HIF25-28 HIF29-32 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 HIF9-12 HIF13-16 HIF17-20 HIF21-24 HIF25-28 HIF29-32 NIF2 NIF3 NIF4
36 Port-channel Pinning VIC 1200/1300 adaptor with DCE links in Port-Channel HIFs 2200-IOM Pinned to Po NIF Gen-1 adaptor with single 10G link HIF
37 Increased Bandwidth Access to Blades 4 links, Discrete - Today 8 links, Discrete Up to 8 links, Port-channel slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X Fabric Interconnect slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X Fabric Interconnect F E X Fabric Interconnect Available bandwidth per blade 10Gb Statically pinned to individual fabric links Deterministic Path Available bandwidth per blade 20Gb Statically pinned to individual fabric links Deterministic Path Guaranteed 10Gb to each blade Available bandwidth per blade up to 160Gb Statically pinned to Portchannel Increased and shared bandwidth Higher Availability
38 Server Connectivity
39 Cisco Virtual Interface Cards (VIC) 1 st Gen (Palo) 2 nd Gen (Sereno) 3 rd Gen (Cruz) M81KR, P81E 128 PCIe devices Dual 10Gb 16x PCIe Gen1 1240, 1280, 12xx 256 PCIe Device Dual 40Gb (4 x 10Gb) 16x PCIe Gen , 1380 Dual 8x PCIe Gen 3 VXLAN & NVGRE Native 40Gb Support RoCE
40 Fabric Extender Evolution Virtual Interfaces VN-TAG/IEEE 802.1BR allows cascading FEXs LIF FEX Cisco VIC is an extension of FEX VN-TAG associates the Logical Interface (LIF) to a Virtual Interface (VIF) VIF Adapter FEX
41 VIC 1240/ Port Expander Card Base option supports dual 2x10Gb Port Expander = passive connector device Port Expander fits in Mezzanine slot mlom vs Mezzanine Sereno Modular LOM (mlom) 1340 Cruz
42 VIC 1240/1340 to IOM Connectivity MLOM only Fabric Interconnects UCS x SFP+ 16x SFP+ Expansion Module 16x SFP+ 16x SFP+ UCS 6248 Expansion Module IO Modules 2208XP 2208XP Midplane Adapter 1340 VIC Empty Dual 2x10 Gb port-channel from VIC 1240/1340 to 2208 IO Modules x8 Gen 3 x8 Gen 3 Server Blade CPU 0 CPU 1 QPI Link B200 M3/M4 UCS Blade Chassis
43 VIC 1240/1340 to IOM Connectivity MLOM plus Port Expander UCS 6248 UCS 6248 Fabric Interconnects 16x SFP+ 16x SFP+ Expansion Module 16x SFP+ 16x SFP+ Expansion Module IO Modules 2208XP 2208XP Midplane Port Channel 1 Port Channel 2 Adapter 1340 VIC x8 Gen 3 Port Exp x8 Gen 3 Port Expander Passive Increase BW to 80Gbps Dual 4x10Gbps Port-channel Server Blade CPU 0 QPI Link CPU 1 B200 M3/M4 UCS Blade Chassis
44 What Does The OS See?
45 Connectivity IOM to Adapter 2208 IOM 2208 IOM Implicit Port-channel Flows hashed across port-channel Side A vnic1 VM Side B UCS 1200/1300 VIC VM Flows Gb FTP traffic Gb UDP traffic UCSB-2-A# connect nxos UCSB-2-A(nxos)# show port-channel summary Group Port- Type Protocol Member Ports Channel Po11(SD) Eth LACP Eth1/11(D) 88 Po88(SD) Eth LACP Eth1/20(D) Po1314(SU) Eth NONE Eth1/1/5(P) 1315 Po1315(SU) Eth NONE Eth1/1/6(P) UCSB-2-A(nxos)# 50
46 VIC 1x40 & 1x80 to IOM Connectivity UCS 6248 UCS 6248 Fabric Interconnects 16x SFP+ 16x SFP+ Expansion Module 16x SFP+ 16x SFP+ Expansion Module IO Modules Midplane 2208XP 2208XP No mixing of 12xx/13xx. Adapter Server Blade 1340 VIC VIC1380 x8 Gen 3 x8 Gen 3 CPU 0 CPU 1 QPI Link Adapter Redundancy Split vnic across adapters 4 2x10 Gb Port-channels B200 M3/M4 UCS Blade Chassis
47 Full Width Blade to IOM Connectivity MLOM, Port Expander, VIC1x80 UCS 6248 UCS 6248 Fabric Interconnects 16x SFP+ 16x SFP+ Expansion Module 16x SFP+ 16x SFP+ Expansion Module IO Modules 2208XP 2208XP Midplane Port Channel 1 Port Channel 2 Adapter 1340 VIC Port Exp 4x10 4x10 VIC1380 Total BW is 160G Four 40G port-channels x8 Gen 3 x8 Gen 3 x8 Gen 3 Server Blade CPU QPI Link CPU B260 M4 UCS Blade Chassis
48 23XX-A 23XX-B IOM 2304 and Adapter Connection VIC1340 Only 20G (2x10G) Active KR Lane Passive KR Lane Mezz 1 (empty) VIC1340 ` PCIe Lanes PCIe Lanes Blade Server QPI CPU # 1 CPU # 0
49 23XX-A 23XX-B 2304 IOM and Adapter Connection VIC1340 Plus Port Expander 40G (native) Port Expander Card VIC1340 ` PCIe Lanes PCIe Lanes Blade Server QPI CPU # 1 CPU # 0
50 23XX-A 23XX-B 2304 IOM and Adapter Connection VIC1340 Plus VIC1380 Adapter Resiliency 2 independent Adapters vcon placement 4 20G connections 20G are 2x10 VIC1380 VIC1340 ` PCIe Lanes PCIe Lanes QPI Blade Server CPU # 1 CPU # 0
51 UCS Mini: Fabric to Server Connectivity Same server-side connectivity as the 2204XP IOM 40G per half width blade
52 Fabric Forwarding - Ethernet
53 Ethernet Fabric Forwarding Mode of Operations LAN Switch mode: FI acts like regular Ethernet switch VLAN/Mac based forwarding End-host mode (EHM): No spanning-tree protocol (STP) Active/Active for all links & VLANs Policy based forwarding
54 End Host Mode Spanning Tree LAN Learn MAC addresses only from server interfaces vnics are pinned to uplink interfaces FI A Fabric A veth 3 veth 1 VLAN 10 L2 Switching MAC Learning MAC Learning VNIC 0 Server 2 VNIC 0 Server 1
55 End Host Mode: Unicast Forwarding FI Uplink Ports LAN VLAN 10 Deja-Vu veth 1 veth 3 Server 2 RPF Policies to prevent packet looping 1. No uplink to uplink forwarding 2. Déjà Vu check 3. RPF No unknown unicast. Silent VM? FI Mac Aging vs. Router ARP Timeout VNIC 0 Server 2 VNIC 0 Server 1
56 End Host Mode: Broadcast Forwarding Uplink Ports FI B LAN Broadcast Listener per VLAN veth 1 veth 3 B Broadcast traffic for a VLAN is pinned to one uplink port only Broadcast Listener prevents duplicate packets Server to server broadcast traffic is locally switched RPF and Déjà Vu check also applies for broadcast traffic. B VNIC 0 Server 2 VNIC 0 Server 1
57 Designated Receiver - Broadcast Uplinks Carrying VLAN 511 Uplink which is the DR for VLAN 511
58 End Host Mode: Disjointed L2 Domains Broadcast Link UCSM by default assumes all uplinks are part of all VLANs Prod (vlans 10,20,30) DMZ (vlans 40,50,60) EHM 6200 A 6200 B EHM Cannot see DMZ 2 Broadcasts Prod Server DMZ Server
59
60 Switch Mode VLAN 10 L2 Switching Root LAN veth 3 veth 1 MAC Learning Fabric Interconnect behaves like a normal L2 switch Rapid-STP+ to prevent loops Server vnic traffic follows STP forwarding states MAC address learning on both uplinks and server links VNIC 0 Server 2 VNIC 0 Server 1
61 Uplink Pinning
62 End Host Mode - Dynamic Pinning FI A vlan10 LAN veth 2 veth 3 veth 1 vlan20,30 Pinning Switching UCSM manages the veth pinning to the uplink Pinned uplink must pass VLAN used by vnic UCSM periodically redistributes the veths vlan10 vlan20 vlan30 VNIC 0 Server 2 VNIC 0 Server 3 VNIC 0 Server 1
63 End Host Mode Individual Uplinks Dynamic Re-pinning of failed uplinks FI-A Fabric A veth 3 Sub-second re-pinning veth 1 Pinning Switching GARP aided upstream convergence Sub-second re-pinning L2 Switching VNIC 0 VNIC stays up VNIC 0 MAC A Server 2 vswitch / N1K ESX HOST 1 VM 1 VM 2 MAC B MAC C
64 End Host Mode Port Channel Uplinks No disruption No GARPs needed More Bandwidth per Uplink No Server NIC disruption Fewer GARPs needed Fewer moving parts RECOMMENDED FI-A Fabric A veth 3 Sub-second convergence VNIC 0 veth 1 NIC stays up VNIC 0 MAC A Server 2 Pinning Switching vswitch / N1K ESX HOST 1 VM 1 VM 2 MAC B MAC C
65 End Host Mode Static Pinning (LAN Pin Group) FI A VNIC 0 Server 2 LAN veth 2 veth 3 veth 1 VNIC 0 Server 3 VNIC 0 Server 1 Pinning Switching Administrator Pinning Definition veth Interfaces veth 1 veth 2 veth 3 Administrator controls the veth pinning Deterministic traffic flow Uplink Blue Blue Purple No re-pinning with in the same FI Static and dynamic pinning can co-exist
66 Which uplink is the servers vnic pinned to? Uplink vnic
67 Fabric Forwarding - Storage
68 SAN End Host NPV Mode N-Port Virtualisation Forwarding NPV FLOGI FDISC SAN A N_Proxy 6200-A 6200-B Server 1 VSAN 1 SAN B N_Proxy vfc 1 vfc 3 vfc 2 vfc 4 vhba 0 NPIV VSAN 10 F_Proxy N_Port F_Port vhba 1 NPIV F_Proxy vhba 0 F_Port VSAN 20 N_Port vhba 1 Server 2 VSAN 1 NPV vhbas are pinned to SAN uplinks FI proxies FC messages to NPIV switch FI in NPV mode means: Uplinks connect to F port No domain ID consumption Multi-vendor interoperability Zoning performed upstream
69 SAN End Host NPV Mode N-Port Virtualisation Forwarding with MDS, Nexus 5000 F_ Port Channel & Trunk SAN A N_Proxy 6200-A 6200-B Server 1 VSAN 1 SAN B vfc 1 vfc 3 vfc 2 vfc 4 vhba 0 NPIV VSAN 1,2 F_Proxy N_Port vhba 1 F_Port NPIV VSAN 1,2 vhba 0 vhba 1 Server 2 VSAN 2 Port channel support Increased Bandwidth Redundancy VSAN Trunking support UCSB-2-B(nxos)# show vsan vsan 1 information name:vsan0001 state:active interoperability mode:default loadbalancing:src-id/dst-id/oxid operational state:up
70 SAN FC Switch Mode Direct Attach FC & FCoE Storage to UCS FC FCoE SAN Optional UCS acts like an FC SAN switch Local or Remote Zoning Direct attached storage MDS MDS N_Port VSAN 1 VSAN 2 TE_Port F_Port 6200-A FC Switch 6200-B FC Switch vfc 1 vfc 3 vfc 2 vfc 4 F_Port vhba 0 N_Port vhba 1 Server 1 VSAN 1 vhba 0 vhba 1 Server 2 VSAN 2
71 3 rd Generation FI Port Allocation Unified Ethernet 40G only UP 6332 Ethernet 40G Only
72 FC Port Configurations Slider bar Left to right Contiguous ports System Reboot 3 blocks Block 1: 6 FC ports (1/1-6) Block 2: 12 FC ports (1/1-12) Block 3: 16 FC ports (1/1-16) FC ports are enable by default
73 Operation Mode vs. Features Operation Mode for FC/FCoE End-Host (NPV) Mode UCS Functions as Node Port (initiator) Required for Connecting FC to Non-MDS FC Switches FC Switching Mode Upstream MDS or Nexus FC Switch Required Required for UCS Local Zoning Feature Direct Connect from Fabric Interconnect to FC/FCoE Storage Target Operation Mode for Ethernet/iSCSI/NAS End-Host Mode Appliance Ports which allow Direct Connect Ethernet/iSCSI/NAS Storage Targets Ethernet Switch No Storage Based Reasons to use this Mode
74 M-Series
75 UCS M-Series Architecture Shared Power & Cooling 2 x 40 Gb Uplinks Shared Resources Independent Server Management Virtual Network Virtual Storage 8 x Cartridge Slots 4 PCIe Gen3 Lanes per Slot Flexible compute and memory
76 System Link Technology Overview System Link Technology is built on proven Cisco Virtual Interface Card (VIC) technologies VIC technologies use standard PCIe architecture to present an endpoint device to the compute resources VIC technology is a key component to the UCS converged infrastructure In the M-Series platform this technology has been extended to provide access to PCIe resources local to the chassis like storage eth0 eth1 operating system eth0 eth1 eth2 eth3 operating system
77 System Link Technology System Link technology provides the same capabilities as a VIC to configure PCIe devices for use by the server The difference with System Link is that it is an ASIC within the chassis and not a PCIe card The ASIC is core to the M-Series platform and provides access to I/O resources The ASIC connects devices to the compute resource through the system mid plane System Link provides the ability to access network and storage shared resources SCSI Commands Virtual Drive
78 System Link Technology Same ASIC used in the 3 rd Generation VIC Cartridges Network M-Series takes advantage of additional features which include: Gen3 PCIe root complex for connectivity to Chassis PCIe cards (e.g Storage) 32 Gen3 PCIe lanes connected to cartridges CPUs 2 x 40Gbps uplinks 32 Lanes Gen3 PCIe 40Gbps QSFP x2 Scale to 1024 PCIe devices created on ASIC (e.g. vnic) Storage
79 / Mapping Network resources to the M-Series Servers The System Link Technology provides the network interface connectivity for all of the servers Virtual NICs (vnic) are created for each server and are mapped to the appropriate fabric through the service profile on UCS Manager Servers can have up to 8 vnics. The operating system sees each vnic as a 40Gbps Ethernet Interface but they can be rate limited and provide hardware QoS marking. Interfaces are 802.1Q capable Fabric Failover is supported, so in the event of a failure traffic is automatically moved to the second fabric Host PCIe Interface eth0 eth1 eth0 eth 1 Fabric Interconnect A Fabric Interconnect B
80 Networking Capabilities The System Link ASIC supports 1024 virtual devices. Current scale limits are 8 vnics per server. All network forwarding is provided by the fabric interconnects, there is no forwarding local to the chassis Currently the network uplinks for the M-Series chassis supports Ethernet traffic only. The M-Series devices can connect to external IP storage volumes like NFS, CIFS, HTTPS, or iscsi. FCoE connectivity will be supported in a future release. iscsi boot is supported see the UCS Interoperability Matrix for details.
81 Typical UCS Deployment
82 Recommended Topology for Upstream Connectivity Access/Aggregation Layer vpc/vss FI-A FI-B
83 UCS VM Traffic Flow All VMs in same VLAN VM1 to VM2 L2 Switching VM1 to VM3 VM1 to VM4 EHM FI-A EHM FI-B VNIC 0 ESX HOST 1 VNIC 1 VNIC 0 ESX HOST 2 VNIC 1 vswitch / N1K Mac Pinning vswitch / N1K Mac Pinning VM1 VM2 VM3 VM4
84 Summary Chassis Connectivity Server Connectivity Fabric Forwarding M-Series
85 Q & A
86 Complete Your Online Session Evaluation Give us your feedback and receive a Cisco 2016 T-Shirt by completing the Overall Event Survey and 5 Session Evaluations. Directly from your mobile device on the Cisco Live Mobile App By visiting the Cisco Live Mobile Site Visit any Cisco Live Internet Station located throughout the venue T-Shirts can be collected Friday 11 March at Registration Learn online with Cisco Live! Visit us online after the conference for full access to session videos and presentations.
87 Thank you
88
UCS Networking Deep Dive
UCS Networking Deep Dive Sarva Chakravarthi Cisco Services UCS LAN Deep Dive - Agenda High-level System Overview Fabric Forwarding Mode of Operations Uplink Pinning Chassis / Fabric Extender Server Connectivity
More informationUCS Networking Deep Dive
UCS Networking Deep Dive BRKCOM-2003 www.ciscolivevirtual.com Agenda Overview / System Architecture Physical Architecture Logical Architecture Switching Modes of the Fabric Interconnect Fabric Failover
More informationUCS Networking 201 Deep Dive
UCS Networking 20 Deep Dive BRKCOM-2003 Brad Hedlund bhedlund@cisco.com Manish Tandon mtandon@cisco.com Agenda Overview / System Architecture Physical Architecture Logical Architecture Switching Modes
More informationUCS Networking Deep Dive
UCS Networking Deep Dive Michael Ciesla, Customer Support Engineer #clmel Agenda UCS Overview Chassis Connectivity Server Connectivity Fabric Forwarding Topologies Cisco Unified Computing System (UCS)
More informationUCS Networking Deep Dive
UCS Networking Deep Dive Steve McQuerry, CCIE # 6108, UCS Technical Marketing @smcquerry 2 UCS LAN Deep Dive Agenda High-level system overview review of different Fabric Interconnects, IOM and Cisco adapters
More informationUCS Fabric Fundamentals
UCS Fabric Fundamentals Hardware State Abstraction MAC Address NIC Firmware NIC Settings UUID BIOS Firmware BIOS Settings Boot Order BMC Firmware Drive Controller F/W Drive Firmware State abstracted from
More informationUCS Fabric Fundamentals
UCS Fabric Fundamentals Hardware State Abstraction MAC Address NIC Firmware NIC Settings UUID BIOS Firmware BIOS Settings Boot Order BMC Firmware Drive Controller F/W Drive Firmware State abstracted from
More informationNext Generation Computing Architectures for Cloud Scale Applications
Next Generation Computing Architectures for Cloud Scale Applications Steve McQuerry, CCIE #6108, Manager Technical Marketing #clmel Agenda Introduction Cloud Scale Architectures System Link Technology
More informationUCS Fundamentals Aaron Kerr, Consulting Systems Engineer
UCS Fundamentals Aaron Kerr, Consulting Systems Engineer Complementary UCS Sessions Check out www.ciscolive.com for previous session presentations and videos BRKCOM-2003 UCS Networking Deep Dive BRKCOM-2007
More informationUCS Fundamentals. Conor Murphy Partner Systems Engineer. #clmel BRKCOM-1001
UCS Fundamentals Conor Murphy Partner Systems Engineer #clmel Abstract This session provides an introduction to Cisco UCS. It does not assume previous UCS familiarity and is intended as a basic introduction
More informationUCS Engineering Details for the SAN Administrator
UCS Engineering Details for the SAN Administrator Craig Ashapa 2 First things first: debunking a myth Today (June 2012 UCS 2.02m) there is no FCoE northbound of UCS unless you really really really want
More informationUCS Fundamentals. Conor Murphy Partner Systems Engineer. #clmel BRKCOM-1001
UCS Fundamentals Conor Murphy Partner Systems Engineer #clmel Abstract This session provides an introduction to Cisco UCS. It does not assume previous UCS familiarity and is intended as a basic introduction
More informationTroubleshooting the Cisco UCS Compute Deployment BRKCOM Cisco and/or its affiliates. All rights reserved.
Troubleshooting the Cisco UCS Compute Deployment 2 Agenda Troubleshooting Cisco UCS Overview Physical Setup Software Setup Configuration Path Tracing Maintenance Key Takeaways Q & A 3 Overview UCS Building
More informationOverview. Cisco UCS Manager User Documentation
Cisco UCS Manager User Documentation, page 1 Infrastructure Management Guide, page 2 Cisco Unified Computing System, page 3 Cisco UCS Building Blocks and Connectivity, page 5 Cisco UCS Manager User Documentation
More informationCisco UCS Network Performance Optimisation and Best Practices for VMware
1 Cisco UCS Network Performance Optimisation and Best Practices for VMware Chris Dunk Technical Marketing Engineer, Cisco UCS #clmel Agenda Server to Server East West Traffic Flow Architecture Why it is
More informationLAN Ports and Port Channels
Port Modes, page 2 Port Types, page 2 UCS 6300 Breakout 40 GB Ethernet Ports, page 3 Unified Ports, page 7 Changing Port Modes, page 10 Server Ports, page 16 Uplink Ethernet Ports, page 17 Appliance Ports,
More informationUCS Technical Deep Dive: Getting to the Heart of the Matter
UCS Technical Deep Dive: Getting to the Heart of the Matter Session ID Agenda Introductions UCS Architecture, Innovations, Topology Physical Building Blocks Logical Building Blocks Typical Use Cases (Live
More informationUsing Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group
Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group 2 UCS Bundled Upgrades Useful for Staging, Labs, and Non Productions This does a very quick fast upgrade
More informationMaailman paras palvelinjärjestelmä. Tommi Salli Distinguished Engineer
Maailman paras palvelinjärjestelmä Tommi Salli Distinguished Engineer Cisco UCS Momentum $1.1B Annualized Run Rate 7,400 UCS Customers; 2,620 repeat customers with average 3.4 repeat buys 350 ATP Channel
More informationCisco Actualtests Questions & Answers
Cisco Actualtests 642-999 Questions & Answers Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 22.8 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot Cisco
More informationCloud Scale Architectures
Next Generation Computing Architectures for Cloud Scale Applications Steve McQuerry, CCIE #6108, Engineering Manager, Technical Marketing James Leach, Principle Engineer, Product Management BRKCOM-2028
More informationUCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2.
UCS-ABC Why Firefly Length: 5 Days Format: Lecture/Lab Course Version: 5.0 Product Version: 2.1 This special course focuses on UCS Administration and Troubleshooting UCS Manager 2.0 and provides additional
More informationEvolution with End-to-End Data Center Virtualization
Evolution with End-to-End Data Center Virtualization Yves Louis DC Virtualisation Technical Solution Architect Agenda Data Center Virtualization Overview Front-End Data Center Virtualization Core Layer
More informationCisco UCS Unified Fabric
Solution Overview Unified Fabric Third Generation of Connectivity and Management for Cisco Unified Computing System 2018 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public
More informationCisco Exam Questions & Answers
Cisco 642-995 Exam Questions & Answers Number: 642-995 Passing Score: 800 Time Limit: 120 min File Version: 36.9 http://www.gratisexam.com/ Exam Code: 642-995 Exam Name: Unified Computing Troubleshoot
More informationVendor: Cisco. Exam Code: Exam Name: DCID Designing Cisco Data Center Infrastructure. Version: Demo
Vendor: Cisco Exam Code: 300-160 Exam Name: DCID Designing Cisco Data Center Infrastructure Version: Demo Exam A QUESTION 1 Which three options are features of a Cisco Nexus 7700 Switch? (Choose three.)
More informationCisco UCS Virtual Interface Card 1400 Series
Data Sheet Cisco UCS Virtual Interface Card 1400 Series Cisco Unified Computing System overview The Cisco Unified Computing System (Cisco UCS ) is a next-generation data center platform that unites computing,
More informationUCS Management Architecture Deep Dive
UCS Management Architecture Deep Dive Agenda Introductions UCS Architecture, Innovations, Topology Physical Building Blocks Logical Building Blocks Typical Use Cases (Live UCS Demo) Programmable Infrastructure
More informationCISCO EXAM QUESTIONS & ANSWERS
CISCO 642-999 EXAM QUESTIONS & ANSWERS Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 32.5 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot CISCO 642-999
More informationFabric Failover Scenarios in the Cisco Unified Computing System
White Paper Fabric Failover Scenarios in the Cisco Unified Computing System What you will Learn Fabric failover is a feature that is unique to the Cisco Unified Computing System (UCS) and is available
More informationOverview. About the Cisco UCS S3260 System
About the Cisco UCS S3260 System, on page 1 How to Use This Guide, on page 3 Cisco UCS S3260 System Architectural, on page 5 Connectivity Matrix, on page 7 Deployment Options, on page 7 Management Through
More informationData Center 3.0 Technology Evolution. Session ID 20PT
Data Center 3.0 Technology Evolution Session ID 20PT Session Goal The focus of this seminar is on the latest technologies some of which can already be used in today's deployments and some that will become
More informationwww.passforsure.co 642-999 www.passforsure.co QUESTION: 1 When upgrading a standalone Cisco UCS C-Series server, which method is correct? A. direct upgrade on all components B. Cisco Hardware Upgrade Utility
More informationActual4Test. Actual4test - actual test exam dumps-pass for IT exams
Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : 642-999 Title : Implementing Cisco Data Center Unified Computing Vendor : Cisco Version : DEMO Get Latest
More informationCisco Nexus 4000 Series Switches for IBM BladeCenter
Cisco Nexus 4000 Series Switches for IBM BladeCenter What You Will Learn This document is targeted at server, storage, and network administrators planning to deploy IBM BladeCenter servers with the unified
More informationTechtorial Datová Centra
Techtorial Datová Centra Sponsor Sponsor Sponsor Sponsor Logo Logo Logo Logo CIscoEXPO 2010 Cisco Systems, Inc. All rights reserved. Cisco Public 1 Vítejte na DC Techtoriálu 11:00-12:00 UCS deepdive 30"
More informationCISCO EXAM QUESTIONS & ANSWERS
CISCO 642-999 EXAM QUESTIONS & ANSWERS Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 32.5 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot CISCO 642-999
More informationQuestion: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?
Volume: 327 Questions Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects? A. primary first, and then secondary
More informationCisco UCS Manager Network Management Guide, Release 3.2
First Published: 2017-08-18 Last Modified: 2018-03-21 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387)
More informationUCS Firmware Management Architecture
UCS Firmware Management Architecture 2 Legal Disclaimer Many products and features described herein remain in varying stages of development and will be offered on a when-and-ifavailable basis. This roadmap
More informationDesigning and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches
Designing and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches What You Will Learn The Cisco Unified Computing System helps address today s business challenges by streamlining
More informationVblock Architecture. Andrew Smallridge DC Technology Solutions Architect
Vblock Architecture Andrew Smallridge DC Technology Solutions Architect asmallri@cisco.com Vblock Design Governance It s an architecture! Requirements: Pretested Fully Integrated Ready to Go Ready to Grow
More informationLayer 2 Implementation
CHAPTER 3 In the Virtualized Multiservice Data Center (VMDC) 2.3 solution, the goal is to minimize the use of Spanning Tree Protocol (STP) convergence and loop detection by the use of Virtual Port Channel
More informationFCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch
FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch Document ID: 117280 Contributed by Padmanabhan, Cisco TAC Engineer. Mar 25, 2014 Contents Introduction Prerequisites Requirements
More informationMidmarket Data Center Architecture: Cisco Unified Computing System with the Cisco Nexus 1000V Switch
White Paper Midmarket Data Center Architecture: Cisco Unified Computing System with the Cisco Nexus 1000V Switch Abstract The Cisco midmarket architecture is designed to meet the needs of businesses with
More information"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary
Description Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary v6.0 is a five-day instructor-led course that is designed to help students prepare for the Cisco CCNP Data Center
More informationVirtual Machine Fabric EXtension (VM-FEX) Extending the Network directly to the VM s
Virtual Machine Fabric EXtension (VM-FEX) Extending the Network directly to the VM s BRKCOM-2005 Follow us on Twitter for real time updates of the event: @ciscoliveeurope, #CLEUR Housekeeping We value
More informationDesign and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems
Design and Implementations of FCoE for the DataCenter Mike Frase, Cisco Systems SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies
More informationQuestions & Answers
642-999 Questions & Answers Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 36.6 http://www.gratisexam.com/ 642-999 Questions & Answers Exam Name: Implementing Cisco Data Center Unified
More informationCisco UCS-Mini with B200 M4 Blade Servers High Capacity/High Performance Citrix Virtual Desktop and App Solutions
In Collaboration with Intel May 2015 Cisco UCS-Mini with B200 M4 Blade Servers High Capacity/High Performance Citrix Virtual Desktop and App Solutions Presenters: Frank Anderson Desktop Virtualization
More informationUCS Management Deep Dive
UCS Management Deep Dive Jeff Silberman UCS Technical Marketing Engineer 2 Agenda Introductions UCS Architecture, Innovations, Topology Physical Building Blocks Logical Building Blocks Typical Use Cases
More informationCisco Nexus B22 Blade Fabric Extender for IBM
Cisco Nexus B22 Blade Fabric Extender for IBM Design and Deployment Guide 2014 Cisco IBM. All rights reserved. Page 1 Contents Introduction... 3 Network Diagram... 3 Hardware Installation... 5 Fabric Extender
More informationCisco CCIE Data Center Written (Beta) Download Full Version :
Cisco 351-080 CCIE Data Center Written (Beta) Download Full Version : https://killexams.com/pass4sure/exam-detail/351-080 Answer: A QUESTION: 105 What is the function of the WWPN pool? A. to assign WWPNs
More informationCisco UCS Virtual Interface Card 1227
Data Sheet Cisco UCS Virtual Interface Card 1227 Cisco Unified Computing System Overview The Cisco Unified Computing System (Cisco UCS ) is a next-generation data center platform that unites computing,
More informationCisco UCS Virtual Interface Card 1225
Data Sheet Cisco UCS Virtual Interface Card 1225 Cisco Unified Computing System Overview The Cisco Unified Computing System (Cisco UCS ) is a next-generation data center platform that unites compute, networking,
More informationEquipment Policies. Chassis/FEX Discovery Policy
/FEX, page 1 Connectivity, page 6 Rack Server, page 7 Aging Time for the MAC Address Table, page 8 /FEX The chassis/fex discovery policy determines how the system reacts when you add a new chassis or FEX.
More informationTraffic Monitoring. Traffic Monitoring
, page 1 Creating a Session, page 6 Editing an Existing Session, page 7 Activating or Deactivating a Session, page 7 Deleting a Session, page 8 Traffic monitoring copies traffic, from one or more source
More informationCisco Nexus 7000 Series Connectivity Solutions for the Cisco Unified Computing System
Cisco Nexus 7000 Series Connectivity Solutions for the Cisco Unified Computing System About the Cisco Nexus 7000 Series Switches The Cisco Nexus 7000 Series Switches combine the highest level of scalability
More informationNexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example
Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Document ID: 116248 Contributed by Jim Hicks and Shelley Bhalla, Cisco TAC Engineers. May 01, 2014 Contents Introduction Prerequisites
More informationVirtual Machine Fabric Extension (VM-FEX)
Virtual Machine Fabric Extension (VM-FEX) Bringing the Virtual Machines Directly on the Network Dan Hanson, Technical Marketing Manager, Data Center Group, CCIE #4482 2 Agenda What This Session Will Cover
More informationImplementing Cisco Data Center Unified Computing (DCUCI)
Implementing Cisco Data Center Unified Computing (DCUCI) Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 3.0 http://www.gratisexam.com/ Exam Topics Implement C-Series stand alone Implementing
More informationCisco.Actualtests v by.Dragan.81q
Cisco.Actualtests.640-916.v2013-10-26.by.Dragan.81q Number: 640-916 Passing Score: 825 Time Limit: 120 min File Version: 12.5 http://www.gratisexam.com/ Exam Code: 640-916 Exam Name: Introducing Cisco
More informationImplementing Cisco Data Center Unified Computing (DCUCI)
Implementing Cisco Data Center Unified Computing (DCUCI) Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 3.0 http://www.gratisexam.com/ Exam Topics Implement C-Series stand alone Implementing
More informationSwitchX Virtual Protocol Interconnect (VPI) Switch Architecture
SwitchX Virtual Protocol Interconnect (VPI) Switch Architecture 2012 MELLANOX TECHNOLOGIES 1 SwitchX - Virtual Protocol Interconnect Solutions Server / Compute Switch / Gateway Virtual Protocol Interconnect
More informationUCS Supported Storage Architectures and Best Practices with Storage
UCS Supported Storage Architectures and Best Practices with Storage First Things First: Debunking a Myth Today (June 2012 UCS 2.01x) there is no FCoE northbound of UCS unless you really, really, really
More informationYou can monitor or use SPAN on port channels only for ingress traffic.
This chapter includes the following sections: Traffic Monitoring, page 1 Guidelines and Recommendations for Traffic Monitoring, page 2 Creating an Ethernet Traffic Monitoring Session, page 3 Creating a
More informationPass-Through Technology
CHAPTER 3 This chapter provides best design practices for deploying blade servers using pass-through technology within the Cisco Data Center Networking Architecture, describes blade server architecture,
More informationTraffic Monitoring and Engineering for UCS
Traffic Monitoring and Engineering for UCS Steve McQuerry, CCIE# 6108 Technical Marketing Engineer Agenda UCS Networking Overview Network Statistics in UCSM Understanding Collection Policies Hotspot Detection
More informationN-Port Virtualization in the Data Center
N-Port Virtualization in the Data Center What You Will Learn N-Port virtualization is a feature that has growing importance in the data center. This document addresses the design requirements for designing
More informationNexus DC Tec. Tomas Novak. BDM Sponsor. Sponsor. Sponsor Logo. Sponsor. Logo. Logo. Logo
Nexus DC Tec Tomas Novak BDM tomnovak@cisco.com Sponsor Sponsor Sponsor Sponsor Logo Logo Logo Logo CIscoEXPO 1 Agenda Nexus 2000 update FEX designs FCoE designs 2 Agenda Nexus 2000 update FEX designs
More informationExpert Reference Series of White Papers. Cisco UCS B Series Uplink Strategies
Expert Reference Series of White Papers Cisco UCS B Series Uplink Strategies 1-800-COURSES www.globalknowledge.com Cisco UCS B Series Uplink Strategies Chris Olsen, Global Knowledge Instructor, Author,
More informationUCS M-Series + Citrix XenApp Optimizing high density XenApp deployment at Scale
In Collaboration with Intel UCS M-Series + Citrix XenApp Optimizing high density XenApp deployment at Scale Aniket Patankar UCS Product Manager May 2015 Cisco UCS - Powering Applications at Every Scale
More informationUCS SAN Deployment Models and Best Practices
UCS SAN Deployment Models and Best Practices Craig Ashapa, Technical Marketing Engineer Topics Introduction of Converged Network Adapters (CNAs) CNAs and Port WWNs Considerations UCS Storage Modes of Operation
More informationVIRTUAL CLUSTER SWITCHING SWITCHES AS A CLOUD FOR THE VIRTUAL DATA CENTER. Emil Kacperek Systems Engineer Brocade Communication Systems.
VIRTUAL CLUSTER SWITCHING SWITCHES AS A CLOUD FOR THE VIRTUAL DATA CENTER Emil Kacperek Systems Engineer Brocade Communication Systems Mar, 2011 2010 Brocade Communications Systems, Inc. Company Proprietary
More informationUCS Direct Attached Storage and FC Zoning Configuration Example
UCS Direct Attached Storage and FC Zoning Configuration Example Document ID: 116082 May 23, 2013 Contents Introduction Prerequisites Requirements Components Used Conventions Background Information UCS
More informationUCS C-Series Deployment Options, Best Practice and UCSM Integration
UCS C-Series Deployment Options, Best Practice and UCSM Integration Steve McQuerry, Manager, Technical Marketing, CCIE #6108 #clmel Agenda Overview and Common Applications C-Series Integration Connectivity
More informationUCS C Series Rack Servers VIC Connectivity Options
UCS C Series Rack Servers VIC Connectivity Options Document ID: 117637 Contributed by Shankar Prasath, Cisco TAC Engineer. Apr 25, 2014 Contents Introduction Prerequisites Requirements Components Used
More informationCisco UCS Local Zoning
Configuration Guide Cisco UCS Local Zoning Configuration Guide May 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 30 Contents Overview...
More informationDell EMC. VxBlock and Vblock Systems 540 Architecture Overview
Dell EMC VxBlock and Vblock Systems 540 Architecture Overview Document revision 1.16 July 2018 Revision history Date Document revision Description of changes July 2018 1.16 Updated Compute Connectivity
More informationConfiguring VM-FEX. Information About VM-FEX. VM-FEX Overview. VM-FEX Components. This chapter contains the following sections:
This chapter contains the following sections: Information About VM-FEX, page 1 Licensing Requirements for VM-FEX, page 3 Default Settings for VM-FEX, page 3, page 4 Verifying the VM-FEX Configuration,
More informationNávrh serverových farem
Návrh serverových farem DCTECH4 Martin Diviš Consulting Systems Engineer mdivis@cisco.com Sponsor Sponsor Sponsor Sponsor Logo Logo Logo Logo CIscoEXPO 1 Agenda Introduction 5k/2k update Basic Concepts
More informationConfiguring Enhanced Virtual Port Channels
This chapter contains the following sections: Information About Enhanced vpcs, page 2 Licensing Requirements for Enhanced vpc, page 4 Configuring Enhanced vpcs, page 4 Verifying Enhanced vpcs, page 5 Enhanced
More informationConfiguring Cisco UCS Server Pools and Policies
This chapter contains the following sections: Global Equipment Policies, page 1 UUID Pools, page 4 Server Pools, page 5 Management IP Pool, page 7 Boot Policy, page 8 Local Disk Configuration Policy, page
More informationAgenda Registration & Coffee
Agenda 09.15 Registration & Coffee 09:45 Welcome & Overview - Paul D'Cruz Data Centre Systems Engineering Manager 10:00 Unified Fabric - Virtualising the Network and Storage Domain - Gordon Hirst DC CSE
More informationManaging Network Adapters
Managing Network Adapters This chapter includes the following sections: Overview of the Cisco UCS C-Series Network Adapters, page 1 Viewing Network Adapter Properties, page 3 Configuring Network Adapter
More informationUCS deployment guide for Nimble Storage
Summary This article is intended as a how to guide to allow for successful deployment of Nimble Storage iscsi connectivity to Cisco UCS. Nimble Storage / Cisco UCS connectivity checklist: 1) Determine
More informationFCoE Cookbook for HP Virtual Connect
Technical whitepaper FCoE Cookbook for HP Virtual Connect Version 4.45 Firmware Enhancements August 2015 Table of contents Change History 6 Purpose 7 Overview 7 Requirements and support 7 Supported Designs
More informationDirect Attached Storage
, page 1 Fibre Channel Switching Mode, page 1 Configuring Fibre Channel Switching Mode, page 2 Creating a Storage VSAN, page 3 Creating a VSAN for Fibre Channel Zoning, page 4 Configuring a Fibre Channel
More informationDisjoint Layer2 Uplinks (DLU)
Disjoint Layer2 Uplinks (DLU) 1 Overview In UCS release 1.4, network facing interfaces are configured to support all VLANs in the system. There is no way to configure a subset of VLANs on a network facing
More informationConfiguring Network-Related Policies
This chapter includes the following sections: Configuring vnic Templates, page 1 Configuring Ethernet Adapter Policies, page 8 Configuring the Default vnic Behavior Policy, page 19 Configuring LAN Connectivity
More informationCisco. Exam Questions DCUCI Implementing Cisco Data Center Unified Computing (DCUCI)
Cisco Exam Questions 642-999 DCUCI Implementing Cisco Data Center Unified Computing (DCUCI) 1. Which two are true with respect to the unified ports on the Cisco Unified Computing System 62XX Fabric Interconnect?
More informationCCIE Data Center Written Exam ( ) version 1.0
CCIE Data Center Written Exam (350-080) version 1.0 Exam Description: The Cisco CCIE Data Center Written Exam (350-080) version 1.0 is a 2-hour test with 80 110 questions that will validate that a data
More informationQ&As. Troubleshooting Cisco Data Center Infrastructure. Pass Cisco Exam with 100% Guarantee
300-180Q&As Troubleshooting Cisco Data Center Infrastructure Pass Cisco 300-180 Exam with 100% Guarantee Free Download Real Questions & Answers PDF and VCE file from: 100% Passing Guarantee 100% Money
More informationConfiguring Cisco UCS Server Pools and Policies
This chapter contains the following sections: Global Equipment Policies, page 1 UUID Pools, page 3 Server Pools, page 5 Management IP Pool, page 7 Boot Policy, page 8 Local Disk Configuration Policy, page
More informationDCNX5K: Configuring Cisco Nexus 5000 Switches
Course Outline Module 1: Cisco Nexus 5000 Series Switch Product Overview Lesson 1: Introducing the Cisco Nexus 5000 Series Switches Topic 1: Cisco Nexus 5000 Series Switch Product Overview Topic 2: Cisco
More informationOverview of Cisco Unified Computing System
Overview of Cisco Unified Computing System This chapter includes the following sections: About Cisco Unified Computing System, page 1 Unified Fabric, page 2 Server Architecture and Connectivity, page 4
More informationUCS Nirvana. Lee Burleson Network and Systems Engineer Iowa National Guard. Cisco ARNG Training Event March 2011
UCS Nirvana I A N G S JOURNEY FROM LEGACY BLADE S E R V E R S T O C I S C O U N I F I E D C O M P U T I N G S Y S T E M, W I T H N O ( N O T I C E A B L E ) V M W A R E D O W N T I M E Lee Burleson Network
More informationService Oriented Virtual DC Design
Dubrovnik, Croatia, South East Europe 20-22 May, 2013 Service Oriented Virtual DC Design Višnja Milovanović Consulting Systems Engineer Data Center & Virtualization 2011 2012 Cisco and/or its affiliates.
More informationAll Roads Lead to Convergence
All Roads Lead to Convergence Greg Scherer VP, Server and Storage Strategy gscherer@broadcom.com Broadcom Corporation 2 Agenda The Trend Toward Convergence over Ethernet Reasons for Storage and Networking
More informationexamcollection.premium.exam.186q
640-916.examcollection.premium.exam.186q Number: 640-916 Passing Score: 800 Time Limit: 120 min File Version: 9.0 640-916 Introducing Cisco Data Center Technologies Version 9.0 Экзамен A QUESTION 1 Which
More information