Data and Voice Network Infrastructure

Size: px
Start display at page:

Download "Data and Voice Network Infrastructure"

Transcription

1 Data and Voice Network Infrastructure Denis Levesque Mike Milne Sponsored By Data and Voice Network Infrastructure Page 1 Copyright APPA 2009

2 Published by APPA: APPA is the association of choice serving educational facilities professionals. APPA's mission is to support educational excellence with quality leadership and professional management through education, research, and recognition. Reprint Statement: Except as permitted under copyright law, no part of this chapter may be reproduced, stored in a retrieval system, distributed, or transmitted in any form or by any means - electronic, mechanical, photocopying, recording, or otherwise - without the prior written permission of APPA. From APPA Body of Knowledge APPA: Leadership in Educational Facilities, Alexandria, Virginia, 2009 This BOK is constantly being updated. For the latest version of this chapter, please visit This chapter is made possible by APPA 1643 Prince Street Alexandria, Virginia Copyright 2009 by APPA. All rights reserved. Data and Voice Network Infrastructure Page 2 Copyright APPA 2009

3 Data and Voice Network Infrastructure Introduction Networking technologies serve as the telecommunications backbone of most universities and colleges, and have a critical role in their operations. The design, installation, and operation of network systems was initially treated as an administrative overhead function and was not typically considered a priority function. The following factors have caused an evolution in how network technologies are used and how academia relies on them: Distribution of data. Most end-user workstations do not have a local copy of all necessary data required by the end user. Institutions commonly use a network operating system to mount virtual disks. Although this solves many problems, such as the ability to archive data, an network outage removes the ability of the user to access this data, and poor network performance, such as congestion and latency, will adversely affect users. Distribution of applications. End users rely heavily on , and business systems are typically architected using a client-server model, or more recently, a web-based model. All such applications require a functional network. Convergence of data, voice, and video services. Many universities and colleges have deployed VoIP (Voice over Internet Protocol) systems to replace legacy telephony systems, and the use of video technologies is growing. Integration of stovepipe networks. Most core infrastructure systems that previously operated on a private stovepipe network are being migrated onto the converged networks. These systems include building automation, access control, intrusion, and fire alarms. Reliance on Internet connectivity. In addition to the factors detailed, organizations increasingly rely on the Internet. Reliable and robust communications must now exist both internal and external to the organization. VoIP as a Driver of Converged Networks Traditionally, large organizations such as colleges and universities have operated dual different network infrastructures, one that provides traditional POTS (Plain Old Telephone Service) and another that provides traditional data-networking services. The POTS network typically used lesser quality wiring such as EIA/TIA Category 3, and connected POTS telephone sets in the user environment to one or more PBX (Private Branch Exchange) systems. Cabling to support data networking was usually installed as an afterthought. Before the widespread availability of commercial-grade VoIP systems, this separation resulted in the expense of installing and operating two different networks. Today, VoIP is the main factor driving converged networks. For new buildings in the planning phases, the major benefit is that both voice and traditional data traffic can be supported over the single physical cable plant designed to carry data traffic. As existing POTS voice equipment reaches its end of life, many organizations are replacing their existing POTS systems with VoIP. In addition to the reduced capital cost building wiring, additional features are present in VoIP Data and Voice Network Infrastructure Page 3 Copyright APPA 2009

4 systems, such as integration with campus directory services and advanced ACD (Automatic Call Distribution). Many VoIP systems also have a programmatic interface that allows organizations to integrate their own applications into the telephony world. Network Architectural Model Networks tend to grow through "osmosis," and, as additional requirements develop, the network is expanded with whatever technologies are "kicking around" or whatever can be purchased at the lowest cost. Although this approach may meet immediate requirements, the net result is that over time, the overall topology of the network will resemble spaghetti. Suboptimal routing paths and congestion are likely to occur, and the ability to sustainably grow the network will diminish. These problems can be avoided by designing and adhering to a network architectural model. Although this may seem like additional work, in the long term it will allow better growth potential, as well as reduce installation and support costs. The "Classic" Network Architectural Model The "classic" model has three distinct layers: Access layer. The purpose of the access layer is to serve as a point of connection for end-user systems. Network switches are typically used to provide connectivity using 100 Mbps Ethernet over UTP (Unshielded Twisted Pair) wiring, but 1,000 Mbps (Gigabit Ethernet) is also used and is likely to grow over time. The access layer is typically located in a TR (telecommunications room), and there is usually at least one TR on each floor in a building. UTP cables run horizontally from the TR out to the end-user workstations. Uplink cables from the access layer to the distribution layer run vertically through the building, and can use either UTP or fiber-optic cables, depending on the distances and speeds involved. Distribution layer. The purpose of the distribution layer is to serve as a connection point to aggregate connections from all of the access layers, as well as to link them to the core layer. There is usually one distribution layer per building. Uplink cables from the distribution layer to the core layer typically use fiber-optic cables, as the distance and speed requirements typically exceed the capabilities of UTP wiring. Core layer. The purpose of the core layer is to serve as the network "backbone" by interconnecting all distribution layers together. Interconnect cables between core layer components typically use fiber-optic cables. Devices that form the core layer are usually connected to each other in a fully meshed topology to provide fault tolerance. Data and Voice Network Infrastructure Page 4 Copyright APPA 2009

5 In the design in Figure 1, Figure 1. An Example of a "Classic" Network Architecture The failure of a core device or connection between the core and distribution devices will not cause a network outage. The failure of a distribution device will cause an outage to the whole building served by the failed device. The failure of an access layer will result in an outage to the floor served by the failed device. Resiliency Improvements Network fault tolerance can be improved by pairing adjacent buildings (i.e., buildings 1 and 3), and adding resilient connections from the access layer of building 1 to the distribution layer of building 3 and vice versa. In the diagram in Figure 2, buildings 1 and 3 use a dual-homed access layer that now protects both buildings against a failure of the distribution layer. The resilient connections are shown in magenta. Network path selection would be done by the IEEE Spanning Tree Protocol, and in the event of a failure, a failover to the alternate path would occur. Note that building 2 has not had this improvement made and its distribution layer is still a single point of failure. Data and Voice Network Infrastructure Page 5 Copyright APPA 2009

6 Figure 2. An Example of a Resilient Network Architecture Resiliency is not normally designed into the access layer, as most end-user workstations have only a single network interface card. The "Collapsed Backbone" Approach Organizations that do not have a large number of buildings or users may benefit from a "collapsed backbone" design, which contains only access and core layers. Figure 3. An Example of a "Collapsed Backbone" Network Architecture Data and Voice Network Infrastructure Page 6 Copyright APPA 2009

7 The primary benefit is the reduced cost, as a distribution layer is not required for each building. The access layers in each building are dual homed to two different core layers for resiliency. This design can also be easily modified to be a classic three-tiered design in the future by simply adding a distribution layer to each building. Structured Cabling Systems Structured cable systems were introduced in the 1980s in an attempt to standardize how building wiring was installed. This standard model keeps cables neat and tidy, prevents them from accidental damage, and creates design-once, build-many model that can be easily replicated as new buildings are constructed. Access Layer to Workstation Figure 4. Structured Cabling Access Layer to Workstation Both the 100- and 1,000-Mbps Ethernet standards, as well as the evolving 10-Gbps Ethernet standard, specify that the maximum length of a cable run from the switch port to the end-user computer cannot exceed 100 meters (325 feet). This cable run length is inclusive of all patch cables. Cables longer than the 100-meter standard will cause excessive signal attenuation and degradation, and ultimately will result in data transmission errors. UTP Wiring Selection Without exception, the common standard used for end-user workstations is Ethernet delivered over UTP wiring; 100 Mbps is the most commonly used speed, and a small and growing amount of 1,000-Mbps workstations are used. UTP cable selection must consider both existing speeds, as well as potential growth and new technologies. EIA/TIA Category 5 wiring will support speeds up to 100 Mbps Ethernet EIA/TIA Category 5e wiring will support speeds up to 1,000 Mbps EIA/TIA Category 6 wiring will support speeds up to 1,000 Mbps Wiring is usually installed during the construction of a building and rewiring a building is possible only with a major renovation. Logic would dictate that any new installations should consider Category 5e wiring as a minimum, as it can support Gigabit Ethernet to the desktop. The standards for 10-Gbps Ethernet are still evolving, but it is unlikely that it will support Category 6 wiring. Adherence to Local Building and Fire Codes The correct cable jacket composition type must be used in accordance with local fire regulations. Cables are designated with a FT rating that indicates its ability to withstand fire. Cables that run through plenum spaces designed for air movement within a building are normally required to use an Data and Voice Network Infrastructure Page 7 Copyright APPA 2009

8 FT-6 fire-rated jacket, whereas nonplenum cables can generally use a lesser FT-4 rating. In addition to the ability to withstand fire, cables with a higher FT rating are less susceptible to act as combustible material that would cause a fire to spread, and may emit a lower level of toxic materials when burned. Readers are cautioned that this information is for example purposes only, and they should consult their local fire and building codes for definitive information. Termination at the Workstation End The cable run is normally terminated at the workstation end in the end-user space with an RJ-45 Jack. These jacks can be wall mounted into drywall/sheetrock walls, mounted against baseboards, installed in Jiffy Poles, or perhaps installed in modular cubicle furniture. The end-user workstation is normally connected to the jack with a patch cable. A jack-numbering and -labeling nomenclature should be developed, and each cable run should be clearly labeled both at the user connection as well as in the telecommunications room (TR). Commercial database software products exist that can assist in accurate record keeping. Termination in the Telecom Room Cable runs are normally terminated in the TR onto a patch panel. Patch cords are then used to connect individual cable runs to the switch ports. Numerous patch panel standards exist, including the following: Those based on BIX patch frames traditionally used by telephone systems Patch panels that terminate the cable run in a standard RJ-45 connector Proprietary methods such as AT&T Systemax. Protection of the Cable Run Cable runs from the TR to the end-user workstation should be as protected as possible, within reason. If the environment is susceptible to vandalism, enclosed cable trays or conduits should be used. Care must be taken to avoid routing UTP cables near sources of electromagnetic or radio frequency interference, and cables should not be close to AC power cables, transformers, electric motors, photocopiers, and the like. Wiring testers from companies such as Fluke Instruments or Tektronix can determine if external interference is causing data errors. Cable Plant Certification Some organizations find it desirable to adhere to an industry or vendor standard such as NORDX/IBDN or AT&T Systemax and build their cable plants to achieve these vendor certifications. If this certification is desired, additional precautions must be taken. This certification can be used to provide a high degree of faith in your physical cable plant, but the cost of achieving this certification can outweigh the benefits. Location of the Telecom Rooms Several items should be considered when deciding where to locate TRs: The TR should be located such that all horizontal cable runs do not exceed the 100-meter length restriction. In large buildings, this may not be possible and may require the creation of more than one TR per floor. The TR footprint should be sized based on the number of end users that will be connected. Consideration should be given to provide additional space to allow for growth. In general, conduits that run vertically in a building are usually located in the center of the building near elevator shafts or stairwells. Ideally, the TRs should be located such that the vertical building conduit runs through the TR. In addition, it is advantageous to stack the TRs such that they are vertically aligned. Data and Voice Network Infrastructure Page 8 Copyright APPA 2009

9 To protect against equipment theft, tampering, and unauthorized connections, TR locations should be lockable with restricted access. Intrusion alarms should be considered if the value of the equipment is high or if a history of theft or vandalism exists. An electrical supply adequate to power all installed equipment must be present. Overcapacity should be considered to account for growth as well as allow for equipment that may be used during troubleshooting. Sufficient ventilation and/or cooling must be present to ensure the room temperature does not exceed the environmental capabilities of the equipment. Both electrical-consumption and heat-generation statistics can be obtained from data sheets provided by the equipment manufacturers. Generally speaking, TRs containing only access layer equipment require only air movement and ventilation, whereas the equipment comprising the distribution and/or core layers will require air-conditioning. If necessary, the use of UPS (Uninterruptable Power Supplies) systems should also be considered to ensure the equipment remains powered in the event of a loss of building power. Telecom rooms do not normally house equipment other than network switches or routers, and once a room is built only small incremental growth (i.e., the addition of a new switch for additional port capacity) is typically experienced. If the rooms will also be used to house servers or other equipment then both the electrical supply and cooling capacities must be sized to accommodate all equipment. The design should also consider potential future growth in terms of rack mounting space, as well as electrical and cooling capacity. Location of Telecom Rooms Containing Core Layer Equipment As outages caused by power failure, construction damage, and natural disasters tend to be localized, TRs containing core layer equipment should be located in different buildings. Uplink Cables Between Access and Distribution Layers Cables between the TRs on each floor and the distribution layer can use either UTP or fiber-optic cables. With existing technologies, if UTP cables are used, the maximum length is 100 meters and speeds exceeding Gigabit Ethernet are not possible. In most cases, links between the access and distribution layers operate as Layer 2 switched trunks, with routing functions being performed by the distribution devices. This allows different VLANS to be deployed in each access layer TR without incurring the expense of Layer 3 routing capabilities in the access layer. Most organizations use fiber-optic cables to link the access layers to the distribution layer. This allows cable lengths to exceed the 100-meter restriction and also provides the ability to migrate to a higher-speed interconnect link such as 10-Gbps Ethernet in the future. Two types of fiber-optic cables exist. Multimode fiber can usually operate up to 2,000 meters in length, whereas singlemode fiber can operate up to 10,000 meters in length. The specific maximum distance requirements that can be used with either type of fiber-optic cable are different depending on the manufacturer. Regardless of the type of cables installed, the cable runs should be clearly labeled at both ends. The fiber-optic cables are typically terminated on patch panels at either end, and patch cords are used to connect the equipment. Location of Telecom Rooms for Distribution and Core Layers The same general considerations apply in the selection of Telecom Rooms for the Distribution and Core Layers as for the Access layer. It is common practice within one building to have the Distribution Layer for a building and the access layer for the floor in the same room. In addition, a Core layer could also be resident in the same room. Data and Voice Network Infrastructure Page 9 Copyright APPA 2009

10 Uplink Cables Between Distribution and Core Layers As the distribution and core layers are typically in different buildings, fiber-optic cables are typically used. To maximize future flexibility in terms of length and speed, singlemode fiber is commonly used. In large campus environments, consideration should also be given to the physical cable layout interconnecting the buildings. Rather than creating a full-mesh connection (running cables from every room directly to every other room), it is common practice to create two or more interconnect junction points, and then connect each building to these common locations. With the appropriate number of patch cords, a full any-to-any connection is easily constructed if necessary. The two distribution uplink cables from each building should also take a diverse physical path to protect against cable cuts. Network Management Considerations Although network management is a large topic, most organizations find that at minimum they need the following knowledge about their networks to deliver reliable service: Knowledge of what network components are functioning properly (i.e., up or down) Knowledge of the traffic levels at key connection points in the network Real-time alerts to inform staff when a device failure occurs or when traffic levels exceed performance thresholds. Most network devices (i.e., switches and routers) support the SNMP (Simple Network Management Protocol). The SNMP is enabled on all network devices, and an SNMP network management workstation then periodically polls the status of each device to determine its availability and performance levels. Many software applications exist for availability monitoring, ranging from open-source (free) tools, to fairly low cost commercial products such as What's Up Gold or Intermapper, through to high-end packages, such as Hewlett Packard Openview. The same wide range of tools exists for traffic and performance monitoring, and most academic organizations use open-source tools such as MRTG (Multi Router Traffic Grapher, or CACTI ( An example screen from a CACTI system is shown in Figure 5. Figure 5. An example screen from a CACTI system Data and Voice Network Infrastructure Page 10 Copyright APPA 2009

11 Thanks to CACTI for use of system. Readers are encouraged to visit for more information on this product. For more information These technologies continue to evolve at a fairly rapid pace and readers are encouraged to consult industry standards. Wiring standards for both copper and fibre based wiring are maintained by TIA/EIA and are available at Standards for Ethernet technologies are maintained by the IEEE and can be obtained at Summary It is highly recommended that APPA members at universities and colleges develop a solid relationship with the information technology organizations that provide computing and communications services to their respective campuses. Clearly, convergence of data, voice, and video services is under way. Relationships with other campus organizations that are responsible for building automation or access control in fact, any communications connectivity should also be nurtured. Facilities organizations need to keep abreast of emerging trends and their impact on the campus physical plant infrastructure. Data and Voice Network Infrastructure Page 11 Copyright APPA 2009

Cabling a Data Center to TIA-942 Standard

Cabling a Data Center to TIA-942 Standard Cabling a Data Center to TIA-942 Standard BICSI 2006 Winter Conference Wednesday, January 25 th 2006 at 9:15 am Gary J. Bernstein, RCDD HellermannTyton Corporation Agenda Overview of TIA-942 Data Center

More information

Enterprise Network Design

Enterprise Network Design Chapter 4 Enterprise Network Design Topics covered: Enterprise Network Design Model. Backbone design concepts. Network security and firewalls. Structured cabling systems. Case studies. Definition An enterprise

More information

ANSI/TIA/EIA-568-B Cabling Standard

ANSI/TIA/EIA-568-B Cabling Standard 83 Pair Numbers and Color Coding The conductors in a UTP cable are twisted in pairs and color coded so that each pair of wires can be easily identified and quickly terminated to the appropriate pin on

More information

Cabling Infrastructure

Cabling Infrastructure Introduction Ethernet Banking on Structured Cabling Technology Drivers Classification of Cables Fibre-optic cable Cables in building Cabling Infrastructure Cabling systems address the networking requirements

More information

Passive optical LAN explained

Passive optical LAN explained Understanding the technology for a more advanced enterprise network Strategic White Paper Network architects have used local area network (LAN) switches to manage the volume of traffic in enterprise networks

More information

ANSI/TIA/EIA-568-B Cabling Standard

ANSI/TIA/EIA-568-B Cabling Standard 73 ANSI/TIA/EIA-568-B Cabling Standard In the mid-1980s, consumers, contractors, vendors, and manufacturers became concerned about the lack of specifications relating to telecommunications cabling. Before

More information

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO Cabling Standards Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO 1. Purpose CABLING STANDARDS This technical note

More information

LACCD IT Design Standards

LACCD IT Design Standards LACCD IT Design Standards March 1 2009 This document establishes a uniform standard for the design of IT Structured Cabling for LACCD. It ensures a secure, consistent, robust system with physical and low-voltage

More information

Newark, Delaware Architectural Engineering Senior Thesis Portfolio

Newark, Delaware Architectural Engineering Senior Thesis Portfolio Telecommunications System Design The represents the advancement of solar design in our world today. The building itself is an example of this. A Headquarters this dedicated to moving into the future should

More information

The following pages contain a guide for the installation

The following pages contain a guide for the installation INDEX The goal of this section is to illustrate how Siemon Company products can be used to support some of the most popular and emerging networks on the market. Section Contents 100Base-T....................................

More information

THE INTERCONNECTED NETWORK

THE INTERCONNECTED NETWORK THE INTERCONNECTED NETWORK The Interconnected Network The number of applications / Services on a network increases from year to year. New applications are permanently in preparation. Server and Server

More information

FTTE Revisited for New Technologies

FTTE Revisited for New Technologies FTTE Revisited for New Technologies A new look into FTTE design to allow great flexibility as well as compliance to the latest 40G and 100G. Gautier Humbert, RCDD, CDCDP Business Development Manager Eastern

More information

Chapter 10: Planning and Cabling Networks

Chapter 10: Planning and Cabling Networks Chapter 10: Planning and Cabling Networks Before using an IP phone, accessing instant messaging, or conducting any number of other interactions over a data network, we must connect end devices and intermediary

More information

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches Product Overview The Cisco Catalyst 2950 Series of fixed configuration, wire-speed Fast Ethernet desktop switches delivers premium

More information

Performance Evaluation of FDDI, ATM, and Gigabit Ethernet as Backbone Technologies Using Simulation

Performance Evaluation of FDDI, ATM, and Gigabit Ethernet as Backbone Technologies Using Simulation Performance Evaluation of FDDI, ATM, and Gigabit Ethernet as Backbone Technologies Using Simulation Sanjay P. Ahuja, Kyle Hegeman, Cheryl Daucher Department of Computer and Information Sciences University

More information

The Conversion Technology Experts. Choosing a Fast Ethernet Media Converter

The Conversion Technology Experts. Choosing a Fast Ethernet Media Converter The Conversion Technology Experts Choosing a Fast Ethernet Media Converter Table of Contents Introduction................................ 3 Extend Distance in a Full-Duplex Environment....... 4 Extend

More information

Enterprise Network Design

Enterprise Network Design Chapter 4 Enterprise Network Design Topics covered: Enterprise Network Design Model. Backbone design concepts. Network security and firewalls. Structured cabling systems. Case studies. Definition An enterprise

More information

GSW-2453 Gigabit Chassis switch. User Guide

GSW-2453 Gigabit Chassis switch. User Guide GSW-2453 Gigabit Chassis switch User Guide Contents 1. INTRODUCTION... 1 Features... 1 Package Contents... 2 Ethernet Switching Technology... 2 2. HARDWARE DESCRIPTION... 4 Physical Dimension... 4 Front

More information

Tarleton State University. Specifications

Tarleton State University. Specifications Tarleton State University Campus Communication Infrastructure Specifications Cabling Standards Summary This document identifies Tarleton State University communication infrastructure standards. The communication

More information

Communication

Communication 27 00 00 Communication 1.01 Scope of Standard A. These guidelines identify and define Texas State University requirements and policies for designing and installing telecommunications infrastructure and

More information

D-Link Switch User Manual. Table of Contents

D-Link Switch User Manual. Table of Contents Table of Contents About This Guide... 1 Terms/Usage... 1 Copyright and Trademarks... 1 Product Introduction... 2 Package Contents... 2 Product Overview... 2 Front Panel... 2 Rear Panel... 2 Indicator LEDs...

More information

Passive Optical LAN Executive Summary. Overview

Passive Optical LAN Executive Summary. Overview Passive Optical LAN Executive Summary Overview Passive Optical LAN (POL) is a solution that provides a great option for enterprises interested in significant capital and operational cost savings. Savings

More information

FIBER OPTIC HARDWARE STEVE PAULOV

FIBER OPTIC HARDWARE STEVE PAULOV C H A P T E R 7 FIBER OPTIC HARDWARE STEVE PAULOV The main purpose for hardware is to protect and organize splice and termination points. Hardware can be divided into two categories; indoor and outdoor.

More information

Product Overview. Switch Features. Catalyst 4503 Switch Features CHAPTER

Product Overview. Switch Features. Catalyst 4503 Switch Features CHAPTER CHAPTER This chapter provides an overview of the features and components of the Catalyst 4500 series switches. The Catalyst 4500 series switches are the Catalyst 4503 switch, the Catalyst 4506 switch,

More information

Fiber backbone cabling in buildings

Fiber backbone cabling in buildings White paper Fiber backbone cabling in buildings www.commscope.com 1 Contents Introduction 3 Backbone cabling speeds 3 Optical fiber in the backbone 3 10 Gbps optical fiber backbone 3 Migrating to 40 Gbps

More information

TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide

TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch User s Guide FCC Warning This equipment has been tested and found to comply with the regulations for a Class A digital device, pursuant to Part 15 of the

More information

Ethernet: Convergence, Choices, Complexities

Ethernet: Convergence, Choices, Complexities Ethernet: Convergence, Choices, Complexities By: Shawn Adams, PANDUIT Global Solutions Manager Introduction Ethernet is penetrating ever deeper into distributed control systems to provide real-time control

More information

THE INVISIBLE UPGRADE: MOVING TO 1Gbps

THE INVISIBLE UPGRADE: MOVING TO 1Gbps READ ABOUT: Decreasing power consumption by upgrading from older 24-port 1U switches to 48-port 1U switches Monitoring Gigabit Ethernet for error rates and link speeds More access points with lower power

More information

Network+ Guide to Networks 7 th Edition

Network+ Guide to Networks 7 th Edition Network+ Guide to Networks 7 th Edition Chapter 4 Structured Cabling and Networking Elements 2016 Cengage Learning. May not be scanned, copied or duplicated, or posted to a publicly accessible website,

More information

Fiber or Copper Which Costs More? Daniel Harman Aug 2006

Fiber or Copper Which Costs More? Daniel Harman Aug 2006 Fiber or Copper Which Costs More? Daniel Harman Aug 2006 LAN Infrastructure Choices Hierarchical Star (Traditional) Centralized Fiber (Fiber to the Desk) FTTE (Fiber to the Telecom Enclosure) Why Compare

More information

Data Center Design and the ANSI/TIA-942 Standard

Data Center Design and the ANSI/TIA-942 Standard Data Center Design and the BICSI Regional Meeting Ellicott, MD Rick Foster RCDD,TLT Communications Infrastructure Group July 27, 2006 What is ANSI/TIA-942? Published by TIA in April 2005 Telecommunications

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

Saving Critical Space. Cable Management Solutions

Saving Critical Space. Cable Management Solutions Saving Critical Space Cable Management Solutions Cable Management Innovation that Saves Space where You Need It Most Enterprise telecom rooms have traditionally housed telecommunications equipment, cable

More information

Leveraging the Structured Cabling System for Security Applications. Mark Dearing, RCDD Leviton Network Solutions

Leveraging the Structured Cabling System for Security Applications. Mark Dearing, RCDD Leviton Network Solutions Leveraging the Structured Cabling System for Security Applications Mark Dearing, RCDD Leviton Network Solutions Trends - Cable Category Mix Source: Leviton projections based on market growth rates Over

More information

Frequently Asked Questions (FAQs) Siemon 10G ip Solutions

Frequently Asked Questions (FAQs) Siemon 10G ip Solutions Frequently Asked Questions (FAQs) Siemon 10G ip Solutions The world of enterprise cabling is evolving rapidly. Emerging, high-bandwidth services and the adoption of higher speed Ethernet standards, like

More information

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch SEL-2730M Managed 24-Port Ethernet Switch Reliably Control and Monitor Your Substation and Plant Networks Features and Benefits Tough Designed, built, and tested for trouble-free operation in extreme conditions,

More information

How You Can Optimize Passive Optical LAN Through Structured Cabling

How You Can Optimize Passive Optical LAN Through Structured Cabling How You Can Optimize Passive Optical LAN Through Structured Cabling Author: Stephane Bourgeois Director Technology Strategy Table of Contents Overview 1 What is POLAN? 1, 2 Deploying a POLAN 2 The Benefits

More information

User Guide. FSW-1641TX/2441TX 16/24 10/100Base-TX Web Smart Switch. FSW-1641TX 16 port 10/100Base-TX Web Smart Switch

User Guide. FSW-1641TX/2441TX 16/24 10/100Base-TX Web Smart Switch. FSW-1641TX 16 port 10/100Base-TX Web Smart Switch FSW-1641TX/2441TX 16/24 10/100Base-TX Web Smart Switch User Guide FSW-1641TX 16 port 10/100Base-TX Web Smart Switch FSW-2441TX 24 port 10/100Base-TX Web Smart Switch Contents 1. PRODUCT INTRODUCTION...1

More information

INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES

INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES University of California, Riverside Computing and Communications April XX, 2001 R1V6 TABLE OF CONTENTS Introduction and Background...3 Outside

More information

4 PWR XL: Catalyst 3524 PWR XL Stackable 10/100 Ethernet

4 PWR XL: Catalyst 3524 PWR XL Stackable 10/100 Ethernet 4 PWR XL: Catalyst 3524 PWR XL Stackable 10/100 Ethernet Table of Contents...1 Contents...1 Introduction...1 Ordering Information...1 Key Features/Benefits...2 Flexible and Scalable Switch Clustering Architecture...3

More information

Physical Layer V What does the physical layer provide?

Physical Layer V What does the physical layer provide? SEMESTER 1 Chapter 8 Physical Layer V 4.0 90 Points 8.1.1 What does the physical layer provide? What are the four elements of delivering frames across the media? 8.1.2 What are the three basic forms of

More information

Peter Sharp RCDD IBI Group

Peter Sharp RCDD IBI Group Peter Sharp RCDD IBI Group Who am I? Presenter Credentials Electrical Engineering Consultant Specialties in communications, electronics and computer sciences, In practice for more than 40 years Member

More information

Cisco EtherSwitch Modules for the Integrated Services Routers Routers

Cisco EtherSwitch Modules for the Integrated Services Routers Routers Cisco EtherSwitch Modules for the Integrated Services Routers Routers 16- and 36-Port 10/100 Ethernet Modules for Cisco 2600/2800/2900/3600/3700/3800/3900 Series Routers Figure 1. Cisco 16-Port and 36-Port

More information

Addressing issues in the local area network

Addressing issues in the local area network Addressing issues in the local area network Enabling the digital enterprise with passive optical LAN Strategic White Paper For more than 30 years, the local area networks (LANs) that enable enterprise

More information

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017. Changes in v2.6: v2.5 was updated May 10, 2016. v2.6 is an updated copy from March 1, 2017. Modifications to 4. Horizontal Pathways section with feedback incorporated from UofA Facilities and Operations

More information

Ether-FSH2400C 24-port 10/100Base-TX Switch

Ether-FSH2400C 24-port 10/100Base-TX Switch Ether-FSH2400C 24-port 10/100Base-TX Switch User s Manual FCC STATEMENT This equipment has been tested and found to comply with the limits for a class A device, pursuant to part 15 of the FCC rules. These

More information

Lecture (07) Media & Switching III Ethernet Protocol & Network Hardware Components

Lecture (07) Media & Switching III Ethernet Protocol & Network Hardware Components Lecture (07) Media & Switching III Ethernet Protocol & Network Hardware Components By: Dr. Ahmed ElShafee ١ Agenda Ethernet Protocol Physical layer Physical layer devices The Data Link Layer ٢ Ethernet

More information

Summer Webinar Series

Summer Webinar Series Summer Webinar Series High-Level Overview of Campus Network Design and Operation. Christopher Rose Sr. Client Network Engineer crose@mcnc.org Webinar Links: www.mcnc.org/cne-webinars Agenda 1. What is

More information

Mellanox Virtual Modular Switch

Mellanox Virtual Modular Switch WHITE PAPER July 2015 Mellanox Virtual Modular Switch Introduction...1 Considerations for Data Center Aggregation Switching...1 Virtual Modular Switch Architecture - Dual-Tier 40/56/100GbE Aggregation...2

More information

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120 DESIGN GUIDELINES PRESTO INSTALLATION & CONNECTIVITY PAGE 1 of 4 ELECTRICAL CONNECTIVITY AND WIRING Communications Conduits Conduits designated for Presto equipment data wiring shall be clearly identified

More information

Technical Document. What You Need to Know About Ethernet Audio

Technical Document. What You Need to Know About Ethernet Audio Technical Document What You Need to Know About Ethernet Audio Overview Designing and implementing an IP-Audio Network can be a daunting task. The purpose of this paper is to help make some of these decisions

More information

Connected & Efficient Building. Field Application Engineer - Kutlugün Sürmeli CommScope

Connected & Efficient Building. Field Application Engineer - Kutlugün Sürmeli CommScope Connected & Efficient Building Field Application Engineer - Kutlugün Sürmeli CommScope Low Voltage Over Twisted Pair Revolution Desktop Voice and Data WiFi Access Control Security Cameras Occupancy Sensors

More information

The six major components of a structured wiring system are:

The six major components of a structured wiring system are: OBJECTIVES 1. Describe various ANSI/TIA/EIA standards for commercial buildings and residential settings. 2. Discuss the specific Technical Systems Bulletins that can affect telecommunications installations.

More information

The Riser as a Contract Document. Peter Sharp, RCDD

The Riser as a Contract Document. Peter Sharp, RCDD The Riser as a Contract Document Peter Sharp, RCDD IBI Group 1 1 Who am I? Presenter Credentials Electrical Engineer Specialties in communications, electronics and computer sciences, In practice for 40

More information

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

Passive Optical LAN - Game Changer: An Integrator s Perspective. Para Munaweera BSc,MSc,MBA

Passive Optical LAN - Game Changer: An Integrator s Perspective. Para Munaweera BSc,MSc,MBA I Passive Optical LAN - Game Changer: An Integrator s Perspective Para Munaweera BSc,MSc,MBA 1 Today's Session Intelligent Buildings and Network Infrastructure Legacy vs POLAN Network Architecture Case

More information

A+ Guide to Managing & Maintaining Your PC, 8th Edition. Chapter 16 Networking Types, Devices, and Cabling

A+ Guide to Managing & Maintaining Your PC, 8th Edition. Chapter 16 Networking Types, Devices, and Cabling A+ Guide to Managing & Maintaining Your PC, Chapter 16 Networking Types, Devices, and Cabling Objectives Learn about network types and topologies Learn about the hardware used to build local networks Learn

More information

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards Anticipating Cat 8 Agenda Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards What is Cat 8? Next Generation Copper Cabling 25G and 40G data rates over twisted pair copper

More information

Checklist for building an edge data center

Checklist for building an edge data center Checklist for building an edge data center Building an edge data center to provide a cloud computing environment within a service provider central office can be a complex endeavor. It requires lots of

More information

Delivered the Way Yo u Want

Delivered the Way Yo u Want SENSAPHONE IMS-4000 Infrastructure Monitoring System Mo nito r What Yo u Want Delivered the Way Yo u Want THE SENSAPHONE IMS-4000 MONITORS AND REPORTS THE INFORMATION THAT YOU NEED TO KNOW: Get critical

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

Fiber Backbone Cabling in Buildings

Fiber Backbone Cabling in Buildings White Paper Fiber Backbone Cabling in Buildings www.commscope.com Contents Introduction 3 Backbone Cabling Speeds 3 Optical Fiber in the Backbone 4 b/s Optical Fiber Backbone 4 Migrating to 40 Gbps and

More information

BT Connect Networks that think Optical Connect UK

BT Connect Networks that think Optical Connect UK BT Connect Networks that think Optical Connect UK Fast, reliable, secure and affordable Connecting the heart of your organisation Your organisation and its people rely on its applications email, databases,

More information

Tellabs Optical Network Terminals

Tellabs Optical Network Terminals TELLABS Tellabs Optical Network A broad portfolio of choices to best result in lowest costs and optimize energy and space savings Overview With explosive demand for high bandwidth in the access network

More information

Zone Cabling for Cost Savings: Plenum Environments

Zone Cabling for Cost Savings: Plenum Environments Zone Cabling for Cost Savings: Plenum Environments Workspaces are becoming increasingly social and flexible and are constantly being re-arranged and updated. To determine how structured cabling can best

More information

Increase Network Reliability and Reduce Costs with Cabling Management Software and Services Designed Especially for SYSTIMAX Installations

Increase Network Reliability and Reduce Costs with Cabling Management Software and Services Designed Especially for SYSTIMAX Installations Here s Why You Need a Cable Management System You ve made a substantial investment in your cabling infrastructure. A cable management system protects that investment by allowing you to: Maximize network

More information

HITEC 2003 Produced by Hospitality Financial and Technology Professionals

HITEC 2003 Produced by Hospitality Financial and Technology Professionals Infrastructure of a Hotel Dan Phillips Bob Stoutenburgh David Hostetter Presenters Dan Phillips Founding partner and COO of ITS Inc., Dan manages and organizes telecommunications and data projects for

More information

TEG-S224TX 26-Port 10/100/1000Mbps Gigabit & Fast Ethernet Switch

TEG-S224TX 26-Port 10/100/1000Mbps Gigabit & Fast Ethernet Switch TEG-S224TX 26-Port 10/100/1000Mbps Gigabit & Fast Ethernet Switch with 2 1000BASE-T plus 24 10/100BASE-T ports User s Guide FCC Warning This equipment has been tested and found to comply with the regulations

More information

User Manual & Modem Installation Guide

User Manual & Modem Installation Guide ..... digital July 2005 Draft Version 07012005 whirlwind 99 Ling Road Rochester, NY 14612 Telephone: 888.733.4396 Fax: 585.865.8930 Email: sales@whirlwindusa.com Technical Support: techsupport@whirlwindusa.com

More information

Overview. Features CHAPTER

Overview. Features CHAPTER CHAPTER 2 This chapter provides these topics that describe the Catalyst 2955 switch, hereafter referred to as the switch. Features, page 2-1 Front-Panel Description, page 2-3 Rear-Panel Description, page

More information

Uniprise Structured Cabling Solutions Guide

Uniprise Structured Cabling Solutions Guide Uniprise Structured Cabling Solutions Guide Exceptional value, proven reliability You re not unrealistic. You re simply looking for a reliable and affordable structured cabling solution; a single portfolio

More information

f) Telecommunications Equipment Rooms

f) Telecommunications Equipment Rooms SECTION 270000 - COMMUNICATIONS PART 1 - GENERAL 1.1 GENERAL REQUIREMENTS A. The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification

More information

Navigating the Pros and Cons of Structured Cabling vs. Top of Rack in the Data Center

Navigating the Pros and Cons of Structured Cabling vs. Top of Rack in the Data Center Navigating the Pros and Cons of Structured Cabling vs. Top of Rack in the Data Center Executive Summary There is no single end-all cabling configuration for every data center, and CIOs, data center professionals

More information

Lecture (03) Ethernet Protocol & Network Hardware Components

Lecture (03) Ethernet Protocol & Network Hardware Components Lecture (03) Ethernet Protocol & Network Hardware Components Dr. Ahmed M. ElShafee 1 Agenda Ethernet Protocol/ and cable types Network interface card Network nodes Servers Clients Storage area network

More information

Network Infrastructure and Services for the Alcoa Building

Network Infrastructure and Services for the Alcoa Building Network Infrastructure and Services for the Alcoa Building Preliminary proposal to the Southwestern Pennsylvania Commission Submitted by Information Renaissance Robert D. Carlitz, Executive Director 600

More information

Information Systems Infrastructure. Learning Objectives. Components of Campus Telecommunications Infrastructure

Information Systems Infrastructure. Learning Objectives. Components of Campus Telecommunications Infrastructure Information Systems Infrastructure APPA-Institute for Facilities Management J. Craig Klimczak, D.V.M., M.S. Chief Information Officer Community College of Baltimore County 800 S Rolling Road Baltimore,

More information

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX KGC-352 Series Installation Guide DOC.070820-KGC-352-1- (C) 2007 KTI Networks Inc. All rights reserved. No part of this documentation

More information

FSW-1610TX FSW-2410TX

FSW-1610TX FSW-2410TX LevelOne FSW-1610TX FSW-2410TX 16/24-Port Fast Ethernet Switch User Manual Version 1.1-0609 FCC Warning This equipment has been tested and found to comply with the regulations for a Class A digital device,

More information

or go home GO SMALL SEPTEMBER 2015 FOR PROFESSIONALS MANAGING THE CABLE AND WIRELESS SYSTEMS THAT ENABLE CRITICAL COMMUNICATIONS STANDARDS

or go home GO SMALL SEPTEMBER 2015 FOR PROFESSIONALS MANAGING THE CABLE AND WIRELESS SYSTEMS THAT ENABLE CRITICAL COMMUNICATIONS STANDARDS SEPTEMBER 2015 FOR PROFESSIONALS MANAGING THE CABLE AND WIRELESS SYSTEMS THAT ENABLE CRITICAL COMMUNICATIONS GO SMALL or go home STANDARDS PAGE 17 WBMMF on the fast track NETWORK MANAGEMENT PAGE 31 Quicken

More information

Capacity Planning for Next Generation Utility Networks (PART 1) An analysis of utility applications, capacity drivers and demands

Capacity Planning for Next Generation Utility Networks (PART 1) An analysis of utility applications, capacity drivers and demands Capacity Planning for Next Generation Utility Networks (PART 1) An analysis of utility applications, capacity drivers and demands Utility networks are going through massive transformations towards next

More information

Design Guidelines for Facilities Construction:

Design Guidelines for Facilities Construction: Western Michigan University Office of Information Technology & Campus Planning, Design & Construction Design Guidelines for Facilities Construction: DESIGN GUIDELINE DG17-12 System Terminology, Definitions,

More information

Transmission Media. Criteria for selection of media. Criteria for selection of media 2/17/2016. Chapter 3: Transmission Media.

Transmission Media. Criteria for selection of media. Criteria for selection of media 2/17/2016. Chapter 3: Transmission Media. Chapter 3: Transmission Media Marks- 20 Transmission Media Transmission media carries the information from sender to receiver. Different types of cables or waves to transmit data. Data is transmitted through

More information

Intranets and Virtual Private Networks (VPNs)

Intranets and Virtual Private Networks (VPNs) Intranets and Virtual Private Networks (VPNs) Definition Private networking involves securely transmitting corporate data across multiple sites throughout an entire enterprise. Creating a truly private

More information

Communications. UNM IT/Telecommunications Guide Specification Communications

Communications. UNM IT/Telecommunications Guide Specification Communications The material below covers specific information we definitely want to be included in the contract documents and may not be a completed specification section. This material is to be highlighted in your preliminary

More information

The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress

The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress 36 Years of Experience CABLExpress is a manufacturer of

More information

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters KC-351 Series Installation Guide -1- DOC.070820-KC-351 (C) 2007 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

Y O UR BUS I N E SS IS ONL Y A S S TR ON G A S YO U R CONNEC T I O N T HE I M P ORTANCE OF R ELI ABLE CO NNECTIVITY W HAT S IN SIDE:

Y O UR BUS I N E SS IS ONL Y A S S TR ON G A S YO U R CONNEC T I O N T HE I M P ORTANCE OF R ELI ABLE CO NNECTIVITY W HAT S IN SIDE: W H I T E PA P E R C O N N E C T I V I T Y Y O UR BUS I N E SS IS ONL Y A S S TR ON G A S YO U R CONNEC T I O N T HE I M P ORTANCE OF R ELI ABLE CO NNECTIVITY W HAT S IN SIDE: The importance of connectivity

More information

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

AS1008-P AS1026-P AS2008-P AS2024-P User Manual Fast Ethernet and Gigabit Ethernet PoE+ Unmanaged Switches AS1008-P AS1026-P AS2008-P AS2024-P User Manual Version 1.0.0.1 Sep 2017 Contents Compliances and Safety Statements... 3 1. AS1000 Series Product

More information

ANSI/TIA/EIA-568-B Cabling Standard NOTE

ANSI/TIA/EIA-568-B Cabling Standard NOTE 95 ANSI/TIA/EIA-569-A Though the ANSI/TIA/EIA-568-B Standard describes the subsystems of a structured cabling system, the TIA has published a more thorough document called ANSI/TIA/EIA-569-A Commercial

More information

3 Chapter Introduction. 3.2 Copper Cable

3 Chapter Introduction. 3.2 Copper Cable 3 Chapter 3 3.1 Introduction The Network Media is the device that physically carries the data from computer to computer. The three major types of network media are: Copper Cable Fiber-Optic Cable Wireless

More information

Business Customer Demarcation Information

Business Customer Demarcation Information Business Customer Demarcation Information The intent of this document is to clearly define Communications terminology and deployment with reference to business data customers and services. 1. What is a

More information

MAN Architecture. How Cisco IT Architected Headquarters MAN. A Cisco on Cisco Case Study: Inside Cisco IT

MAN Architecture. How Cisco IT Architected Headquarters MAN. A Cisco on Cisco Case Study: Inside Cisco IT MAN Architecture How Cisco IT Architected Headquarters MAN A Cisco on Cisco Case Study: Inside Cisco IT 1 Overview Challenge: Rapid growth and IP telephony required a new standard platform for the Cisco

More information

Data and Computer Communications

Data and Computer Communications Data and Computer Communications CHAPTER 1 Tenth Edition by William Stallings Data Communications, Data Networks, and the Internet Data and Computer Communications, Tenth Edition by William Stallings,

More information

GSW-1657 GSW User's Guide. 16/24-port Gigabit Ethernet Switch. Ver

GSW-1657 GSW User's Guide. 16/24-port Gigabit Ethernet Switch. Ver GSW-1657 GSW-2457 User's Guide 16/24-port Gigabit Ethernet Switch Ver.1.0.0-0803 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. Level One is a registered trademark of Digital

More information

10/100/1000Mbps. Gigabit Ethernet Switch GSW-2401/GSW User's Manual

10/100/1000Mbps. Gigabit Ethernet Switch GSW-2401/GSW User's Manual 10/100/1000Mbps Gigabit Ethernet Switch GSW-2401/GSW-1601 User's Manual Trademarks Copyright PLANET Technology Corp. 2005. Content subjects to revision without prior notice. PLANET is a registered trademark

More information

Architecting the High Performance Storage Network

Architecting the High Performance Storage Network Architecting the High Performance Storage Network Jim Metzler Ashton, Metzler & Associates Table of Contents 1.0 Executive Summary...3 3.0 SAN Architectural Principals...5 4.0 The Current Best Practices

More information

User Guide TL-SG1005D TL-SG1008D. 5/8-Port Gigabit Desktop Switch. alarm shop. Rev:

User Guide TL-SG1005D TL-SG1008D. 5/8-Port Gigabit Desktop Switch. alarm shop. Rev: User Guide TL-SG1005D TL-SG1008D 5/8-Port Gigabit Desktop Switch Rev:2.0.2 7106503707 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES

More information

Deploying 10 Gigabit Ethernet with Cisco Nexus 5000 Series Switches

Deploying 10 Gigabit Ethernet with Cisco Nexus 5000 Series Switches Deploying 10 Gigabit Ethernet with Cisco Nexus 5000 Series Switches Introduction Today s data centers are being transformed as the most recent server technologies are deployed in them. Multisocket servers

More information

Meraki MS22 / MS42 Cloud Managed Gigabit PoE Switch Family

Meraki MS22 / MS42 Cloud Managed Gigabit PoE Switch Family DATASHEET Meraki MS22 / MS42 Cloud Managed Gigabit PoE Switch Family Overview The Meraki MS line of cloud-managed access switches bring the benefits of cloud computing, including management simplicity,

More information

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001 Installation Guide DOC.050523-EM400X -1- The information contained in this document is subject to change without prior notice. Copyright (C) All

More information