Level Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview.

Size: px
Start display at page:

Download "Level Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview."

Transcription

1 SITRANS LU and LU Siemens AG Overview Overview The SITRANS LU is an ultrasonic long-range level controller for liquids and solids in a single vessel up to 6 m ( ft). Handheld programmer shown is an accessory and must be ordered separately. Benefits Single point, long-range level monitoring Easy to install; easy to program using removable infrared keypad ompatible with all Echomax transducers Backlit LD display with reading in standard engineering units Automatic level-to-volume conversion for standard or custom tank shapes Dolphin lus and SmartLinx compatible High/low alarms Application Application The system consists of a SITRANS LU monitor linked to a noncontacting ultrasonic transducer that can be mounted up to 36 m ( ft) away. The SITRANS LU will measure distance, level or volume, and it features patented Sonic Intelligence echo processing software for superior reliability. Readings are displayed in user-selectable linear engineering units on the backlit LD. An on-board communications port automatically configures for, RS-8 or bi-polar current loop. The SITRANS LU will connect to a DS or L using Siemens SmartLinx interface modules, giving you remote -way communication and full parameter access. Modules for popular industrial buses can be factory installed or added later to meet changing needs. No external gateway is required, reducing hardware and cabling costs. Key Applications: chemical storage, liquid storage, bulk solids storage (gravel, flour bins, grains, cereals), plastic pellets The SITRANS LU is a dual point ultrasonic long-range level controller for liquids and solids in one or two vessels up to 6 m ( ft). Handheld programmer shown is an accessory and must be ordered separately. Benefits Dual point, long-range level monitoring Easy to install; easy to program using removable infrared keypad ompatible with all Echomax transducers Backlit LD display with reading in standard engineering units Automatic level-to-volume conversion for standard or custom tank shapes Dolphin lus and SmartLinx compatible High/low alarms SITRANS LU will measure liquids, solids or a combination of both in one or two vessels of different sizes, shapes and configurations up to 6 m ( ft). The system uses ultrasonic technology to measure level, space, distance, volume or average/differential. It features patented Sonic Intelligence echo processing software for superior reliability. Transducers can be mounted up to 36 m ( ft) from the monitor. Readings are displayed in user-selectable linear engineering units on the backlit LD. It features an onboard communications port that automatically configures for, RS-8 or bi-polar current loop. It will connect to a DS or L using Siemens SmartLinx interface modules, giving you remote -way communication and full parameter access. Modules for popular industrial buses can be factory installed or added later to meet changing needs. No external gateway is required, reducing hardware and cabling costs. Key Applications: chemical storage, liquid storage, bulk solids storage (gravel, flour bins, grains, cereals), plastic pellets, tripper car /6 Siemens FI

2 Siemens AG Level Measurement SITRANS LU and LU Technical specifications Mode of operation Measuring principle Measuring range Measuring points Output signal Ultrasonic transducer s output Max. load Resolution Ultrasonic level measurement m (... ft) SITRANS LU: Max. one point; SITRANS LU Max. two points Echomax series, ST-H transducers SDT Form relays, rated at A at V A, resistive load /..., optically isolated 7 Ω, isolated, 3 V. of range SITRANS LU: Max. output SITRANS LU: Max. outputs Accuracy Error in measurement. of range or 6 mm (."), whichever is greater Resolution. of measuring range or mm (.8"), whichever is greater Temperature compensation º ( ºF) Integral temperature sensor External TS-3 temperature sensor rogrammable fixed temperature Rated operating conditions Ambient conditions Ambient temperature for enclosure º ( ºF) Design Weight.7 kg (6 lbs) Material (enclosure) olycarbonate Degree of protection (wall mount) I6 Electrical connection Ultrasonic transducer cable extension output signal Electrical connection and relay connection Synchronization RG6-A/U coaxial cable with low capacitance -core copper conductor, twisted, shielded, mm² (... 8 AWG), Belden 876 or equivalent is acceptable opper conductor according to local requirements, rated V A Up to 6 LU/LU units can be synchronized together ower supply A model ///3 V A ±, /6 Hz, 3 VA D model V D, W Displays and controls x 7 mm ( x ") graphics LD with backlighting Memory EEROM (non-volatile), no backup battery required rogramming Using removable programmer (ordered separately) or Dolphin lus (option) ertificates and approvals E, SA US/, FM, ATEX II 3D Lloyd s register of Shipping (ategories ENV, ENV, ENV3 and ENV) Options External temperature sensor TS-3 ommunications SmartLinx: protocol-specific modules as interface for popular industrial fieldbus systems Dolphin lus: Siemens Windows -compatible interface and omverter link (infrared) Siemens FI /7

3 SITRANS LU and LU Siemens AG Selection and Ordering data Order No. SITRANS LU/LU Single or dual point ultrasonic long-range level monitoring system for liquids and solids, and ranges ) 7 M L up to 6 m ( ft). Number of measuring points LU version, point LU version, points Input voltage ///3 V A, voltage selector switch A V D B Feature software Standard A Application software Standard Data communications No module (SmartLinx ready) SmartLinx Allen-Bradley Remote I/O module SmartLinx ROFIBUS D module SmartLinx Modbus RTU module 3 Enclosure Wall mount Wall mount, drilled, 6 x M 3 Approvals E, SA US/, FM ) A E ) B ATEX II 3D ) ) Available with enclosure option only ) Available with enclosure option 3 only ) Subject to export regulations AL: N, EN: EAR99 Selection and Ordering data Order code Further designs lease add "-Z" to Order No. and specify Order code(s). Stainless steel tag [69 x mm (.7 x.97")]: Y Measuring-point number/identification (max. 6 characters) specify in plain text Operating Instructions Order No. SITRANS LU English ) 7ML998-BE French ) 7ML998-BE German ) 7ML998-BE3 SITRANS LU English ) 7ML998-BD French ) 7ML998-BD German ) 7ML998-BD3 Note: The Operating Instructions should be ordered as a separate line item. This device is shipped with the Siemens Milltronics manual D containing the complete ATEX Quick Start and Operating Instructions library. Other Operating Instructions SmartLinx Allen-Bradley Remote I/O, English ) 7ML998-A3 SmartLinx ROFIBUS D, English ) 7ML998-AQ3 SmartLinx ROFIBUS D, German ) 7ML998-AQ33 SmartLinx ROFIBUS D, French ) 7ML998-AQ SmartLinx Modbus, English ) 7ML998-BF SmartLinx Modbus, German ) 7ML998-BF3 SmartLinx Modem, English ) 7ML998-BG Note: The appropriate SmartLinx Operating Instructions should be ordered as a seperate line on the order. Accessories Handheld programmer 7ML83-AN Tag, stainless steel, x mm (.7 x.77"), 7ML93-A one text line, suitable for enclosures M cable gland kit (6 M cable glands, 7ML83-GM 6 M nuts, 3 stop plugs) TS-3 Temperature Sensor - 7ML83-AN see TS-3 on page /9 Spare parts ard, LU mother main, A, comm ready )7ML83-KX ard, LU mother main, A, comm ready )7ML83-MA ard, LU daughter, comm ready )7ML83-L ard, LU daughter, comm ready )7ML83-LN ard, display )7ML83-LQ See SmartLinx product page /3 for more information. ) Subject to export regulations AL: N, EN: EAR99 Modbus is a registered trademark of Schneider Electric. Allen-Bradley is a registered trademark of Rockwell Automation. TM DeviceNet is a trademark of Open DeviceNet Vendor Association (ODVA). /8 Siemens FI

4 3 X X 3 X X Siemens AG Level Measurement SITRANS LU and LU Dimensional drawings 8 (.) 6 (.) 67 (.) 9 (3.6) 8 (.) 6 (.) 67 (.) 9 (3.6) 9 (8.) 7 (6.8) (8.) 7 (6.8) SITRANS LU SITRANS LU Suitable location for conduit entrances. Use water-tight conduit hubs to maintain enclosure rating. Mounting hole.3 (.7) diameter access under lid ( places) Suitable location for conduit entrances. Use water-tight conduit hubs to maintain enclosure rating. Mounting hole.3 (.7) diameter access under lid ( places) Dimensional drawings for SITRANS LU (left) and SITRANS LU (right), dimensions in mm (inch) Siemens FI /9

5 SITRANS LU and LU Schematics Siemens AG A Model Note WHT/ WHT/ WHT/ WHT/ 3 RS-8 L/N L osition SW for // /3 VA Operation (/6 Hz 3 VA) D Model Note WHT/ WHT/ WHT/ WHT/ 3 RS-8 + V Notes:. Optically isolated, 7 Ω max. load. Use RG6-A/U coaxial (or equivalent) for extensions up to 36 m ( ft). Run in grounded metal conduit, separate from other wiring. 3. Each relay has set of Form '' (SDT) contacts, relay rated at A V A, non-inductive, when equal or lower rated limiting fuses are installed.. Required if mounted adjacent to other SITRANS LU units or other specified Siemens Milltronics devices. Interconnect all '' terminals with a single 8 AWG (.mm ) wire. SITRANS LU connections A Model Note WHT/ WHT/ WHT/ WHT/ 3 RS-8 L/N L osition SW for // /3 VA operation (/6 Hz 3 VA) D Model Note: Note WHT/ WHT/ WHT/ WHT/ 3. Optically isolated, 7 Ω max. load. Use RG6-A/U coaxial (or equivalent) for extensions up to 36 m ( ft). Run in grounded metal conduit, separate from other wiring. 3. Each relay has set of Form '' (SDT) contacts, relay rated at A V A, non-inductive, when equal or lower rated limiting fuses are installed.. Required if mounted adjacent to other SITRANS LU units or other specified Siemens Milltronics devices. Interconnect all '' terminals with a single 8 AWG (.mm ) wire. RS-8 + V SITRANS LU connections /6 Siemens FI

Level instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI

Level instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI SITRANS LUC00 Siemens AG 009 Overview SITRANS LUC00 is a complete ultrasonic level controller for monitoring and control of water distribution and wastewater collection systems, with energy-saving algorithms.

More information

SITRANS L Level instruments

SITRANS L Level instruments Overview Technical specifications Mode of Operation Measuring principle Ultrasonic level measurement Measuring range 0.3 to 1 m (1 to 0 ft), transducer dependent Measuring points 1 or 2 Input Analog 0

More information

Continuous level measurement Ultrasonic controllers

Continuous level measurement Ultrasonic controllers Siemens AG 0 Overview is a complete ultrasonic level controller for monitoring and control of water distribution and wastewater collection systems, with energy-saving algorithms. Benefits Monitoring and

More information

Level Measurement Continuous level measurement - Ultrasonic controllers

Level Measurement Continuous level measurement - Ultrasonic controllers Continuous level measurement Ultrasonic controllers Overview is a versatile short to mediumrange ultrasonic single and multivessel level monitor/controller for virtually any application in a wide range

More information

Level Measurement Continuous level measurement Ultrasonic controllers

Level Measurement Continuous level measurement Ultrasonic controllers Overview is a versatile short to mediumrange ultrasonic single and multivessel level monitor/controller for virtually any application in a wide range of industries. Application can be used with various

More information

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview Overview The is a universal input, panel mount remote digital display for process instrumentation. Benefits Easy setup and programming via front panel buttons or remotely using RD software Display readable

More information

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min. Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

AiRanger DPL Plus. Dual-Point Ultrasonic Level Measurement System

AiRanger DPL Plus. Dual-Point Ultrasonic Level Measurement System AiRanger DPL Plus Dual-Point Ultrasonic Level Measurement System Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic dual-point level scanner controller with transceiver

More information

Level Measurement Continuous level measurement Ultrasonic controllers

Level Measurement Continuous level measurement Ultrasonic controllers Overview The Siemens controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, and solids, and high accuracy monitoring of

More information

Level Measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series 5/337. Overview

Level Measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series 5/337. Overview Overview The Siemens controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, and solids, and high accuracy monitoring of

More information

Level Measurement Continuous level measurement - Ultrasonic controllers

Level Measurement Continuous level measurement - Ultrasonic controllers SITRANS LUT00 series Overview The SITRANS LUT00 series controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, solids,

More information

Level Measurement Continuous level measurement - Ultrasonic controllers

Level Measurement Continuous level measurement - Ultrasonic controllers SITRANS LUT00 series Overview The SITRANS LUT00 series controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, solids,

More information

Siemens AG Continuous level measurement Ultrasonic controllers

Siemens AG Continuous level measurement Ultrasonic controllers Overview The Siemens controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, and solids, and high accuracy monitoring of

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and

More information

Level measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series. 4/146 Siemens FI Overview

Level measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series. 4/146 Siemens FI Overview Level measurement SITRNS LUT00 series Siemens G 2013 Overview pplication The SITRNS LUT00 comes in three different models, depending on the application, level of performance and functionality required:

More information

Level Measurement. Continuous level measurement Ultrasonic controller. SITRANS LUT400 series 5/337. Overview

Level Measurement. Continuous level measurement Ultrasonic controller. SITRANS LUT400 series 5/337. Overview Overview The Siemens controllers are compact, single point, long-range ultrasonic controllers for continuous level measurement of liquids, slurries, and solids, and high accuracy monitoring of open channel

More information

Weighing Electronics Stand-alone integrators

Weighing Electronics Stand-alone integrators Overview pplication operates with any solids flowmeter with up to two strain gauge load cells or LVDT sensor. The SF500 processes sensor signals for accurate flow rate and totalized weight of bulk solids.

More information

Engineering Specifications HydroRanger 200. Multi-Functional Level Control System

Engineering Specifications HydroRanger 200. Multi-Functional Level Control System General Engineering Specifications HydroRanger 200 Multi-Functional Level Control System Scope This section describes the requirements for a multi-functional level controller system. Under this item, the

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Level Measurement Continuous level measurement - Ultrasonic transducers

Level Measurement Continuous level measurement - Ultrasonic transducers Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance Optional foam

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. This general purpose, 2-wire, to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials in open

More information

Weighing Electronics Stand-alone integrators

Weighing Electronics Stand-alone integrators Siemens AG 017 Overview Benefits Automatic zero and electronic span calibration Alarms for rate, load, speed, or diagnostic error On-board Modbus, optional PROFIBUS DP, PROFINET, Modbus TCP/IP, EtherNet/IP,

More information

Continuous level measurement Ultrasonic transducers

Continuous level measurement Ultrasonic transducers Siemens G 2013 Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221 Siemens AG 2011 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)

More information

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview.

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview. Overview onfiguration 2-wire, 78 GHz FMW radar level transmitter for continuous monitoring of solids in silos to a range of 100 m (329 ft). enefits rugged stainless steel design for industrial applications

More information

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER Datasheet ECHOMX XPS-10 ULTRSONIC TRNSDUCER Supplied by.com Call us on + (0)118 916 920 Email info@27able.com Overview transducers use ultrasonic technology to measure level in a wide range of liquids

More information

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31 Level instruments Overview The unique modular design of the provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific

More information

Process Instrumentation. Ultrasonic level. Solutions for a world of applications. usa.siemens.com/level

Process Instrumentation. Ultrasonic level. Solutions for a world of applications. usa.siemens.com/level Process Instrumentation Ultrasonic level Solutions for a world of applications usa.siemens.com/level 3 2 Since the early 1970s... Siemens has been your partner in ultrasonic level measurement. This experience

More information

Weighing Electronics

Weighing Electronics Siemens AG 011 Weighing Electronics / Stand-alone Integrators / Introduction /3 Milltronics BW100 /7 Milltronics BW500 /11 Milltronics SF500 /15 Accessories /15 Dolphin Plus Software /16 SITRANS RD100

More information

Instruction Manual September sitrans LU 02

Instruction Manual September sitrans LU 02 Instruction Manual September 2005 sitrans LU 02 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.

More information

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic

More information

Continuous level measurement Ultrasonic transducers

Continuous level measurement Ultrasonic transducers Siemens G 2012 Level measurement Overview EchoMax XPS/XCT transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing

More information

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195 Overview MASS 6000 is based on the latest developments within digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against

More information

Level Measurement Products Ultrasonic Level Products

Level Measurement Products Ultrasonic Level Products Siemens Industry, Inc / IA / Process Instruments Level Measurement Products Ultrasonic Level Products Restricted Siemens Industry, Inc. 2015 All rights reserved. Answers for industry. SITRANS Probe LU

More information

Continuous level measurement Ultrasonic transducers

Continuous level measurement Ultrasonic transducers Siemens G 2012 Level Measurement Overview Echomax XPS/XCT transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing

More information

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter A trademark of Spirax Sarco, Inc. Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter Description Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive,

More information

Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters Overview Configuration Installation Note: Beam angle is the width of the cone where the energy density is half of the peak energy density Emission The peak energy density cone is directly in front of and

More information

SITRANS LU 02. Instruction Manual January 2002

SITRANS LU 02. Instruction Manual January 2002 SITRANS LU 02 Instruction Manual January 2002 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.

More information

Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration

Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration Level instruments Overview Configuration is a versatile inverse frequency shift capacitance level slurries, foam and interfaces. The digital version (with PROFIBUS PA) includes a display and provides additional

More information

Gladiator. Vibration Smart Switch Series. Data Sheet. Overview. A Higher Level of Performance. A level switch for liquids and solids

Gladiator. Vibration Smart Switch Series. Data Sheet. Overview. A Higher Level of Performance. A level switch for liquids and solids Gladiator Admittance Smart Switch Series A Higher Level of Performance Data Sheet Gladiator Vibration Smart Switch Series A level switch for liquids and solids For more information, please visit > www.hawkmeasure.com

More information

Gladiator. Vibration Smart Switch Series. Data Sheet. A Higher Level of Performance. A level switch for liquids and solids.

Gladiator. Vibration Smart Switch Series. Data Sheet. A Higher Level of Performance. A level switch for liquids and solids. A Higher Level of Performance Data Sheet Gladiator Vibration Smart Switch Series A level switch for liquids and solids For more information, please visit > www.hawkmeasure.com Overview The Gladiator Smart

More information

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on Overview SITRANS FUG1010 clamp-on non-intrusive ultrasonic flow transmitter is ideal for natural and process gas applications, including checkmetering, allocation, production, storage and gas fired power

More information

SITRANS F flowmeters SITRANS F US

SITRANS F flowmeters SITRANS F US SITRANS F flowmeters Siemens AG 2008 Overview Application SITRANS FUG1010 is ideal for most natural and process gas industry applications, including: Checkmetering Allocation Flow survey verification Lost

More information

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid The Echotouch, EchoSpan and EchoSwitch are innovative ultrasonic liquid level sensor families that replace float, conductance and pressure sensors that

More information

EnviroRanger ERS 500 Installation Guide PL-557 Nov 1999

EnviroRanger ERS 500 Installation Guide PL-557 Nov 1999 EnviroRanger ERS 500 Installation Guide PL-557 Nov 1999 33455570 Rev 2.0 Ultrasonic level Radar At Milltronics, we endeavour to design equipment that is simple to use and reliable in its operation, with

More information

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview Flow Measurement Siemens AG 2012 Overview Design The transmitter is designed as either IP67 NEMA 4X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack

More information

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview Overview The combination of sensor SONO 3300 sensor and FUS060 transmitter is ideal for applications within the general industry. Measurements are independent of liquid temperature, density, pressure and

More information

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid The Echotouch, EchoSpan and EchoSwitch are innovative ultrasonic liquid level sensor families that replace float, conductance and pressure sensors that

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview MASS 6 is based on digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against process noise, easy to install,

More information

ULTRASONIC LEVEL METERS ULM 53L

ULTRASONIC LEVEL METERS ULM 53L Preliminary data ULTRASONIC LEVEL METERS ULM 53L For continuous level measurement of liquids (even if polluted), mash and paste materials in open or closed vessels, sumps, open channels, etc. Customer

More information

Continuous level measuring system NB 3000 Selection list

Continuous level measuring system NB 3000 Selection list Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------

More information

Level-Lance Model 5400A

Level-Lance Model 5400A Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing

More information

MMT330 Series Moisture and Temperature Transmitters for Oil

MMT330 Series Moisture and Temperature Transmitters for Oil MMT330 Series Moisture and Temperature Transmitters for Oil Features Continuous online measurement of moisture in oil Ball-valve installation no need to shut down the process or drain the oil Proven Vaisala

More information

4110 HART Level Encoder

4110 HART Level Encoder 4110 HART Level Encoder Precision encoding instrument for transmission of level measurement from mechanical float gauges Features Universal connection - mounts to all standard float gauges Low maintenance

More information

SITRANS F flowmeters. SITRANS F C Transmitter MASS 6000 for 19" insert/19" wall mounting. 4/134 Siemens FI

SITRANS F flowmeters. SITRANS F C Transmitter MASS 6000 for 19 insert/19 wall mounting. 4/134 Siemens FI Overview MASS 6000 is based on the latest developments within digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against

More information

Family of Water Cut Analyzers

Family of Water Cut Analyzers Phase Dynamics Technology for Precision Measurements Phase Dynamics, Inc. 1251 Columbia Drive Richardson, TX 75081 USA E-Mail sales@phasedynamics.com Tel: 972-680-1550 Fax: 972-680-3262 Family of Water

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview MASS 6 is based on digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against process noise, easy to install,

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview SITRNS F flowmeters Siemens G 2009 Overview SITRNS FUS1010 is the most versatile clamp-on ultrasonic flow display computer available today. It can operate in either Wide- Beam Transit-Time or Reflexor

More information

Configuration. Installation

Configuration. Installation Overview SITRANS LR20 measures superbly in small vessels and in tanks/vessels up to 10 m (32 ft) on materials with dk > 3. Key Applications: liquid bulk storage tanks, process vessels with agitators, vaporous

More information

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT A0-10 ANALOG OUTPUT Instruction Manual April 2001 NALOG OUTPUT Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the

More information

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on Overview SITRANS UE1010 is a highly accurate clamp-on non-intrusive ultrasonic flow transmitter for revenue grade thermal energy sub-metering and energy efficiency distribution monitoring, with a real

More information

PTU300 Combined Pressure, Humidity and Temperature Transmitter

PTU300 Combined Pressure, Humidity and Temperature Transmitter PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface

More information

Ground Monitoring Device Series 8485

Ground Monitoring Device Series 8485 www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with

More information

Ultrasonic Transmitters SITRANS LU150. Operating Instructions

Ultrasonic Transmitters SITRANS LU150. Operating Instructions Ultrasonic Transmitters Operating Instructions Edition 03/2016 Introduction 1 Description 2 Installing and mounting 3 Ultrasonic transmitters Operating Instructions Connecting 4 Commissioning 5 Operating

More information

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution DATA SHEET Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.:

More information

Clamp-On Ultrasonic Flow- and Energy Meter For Liquids

Clamp-On Ultrasonic Flow- and Energy Meter For Liquids ultrasonic flow and energy meters clamp onto the outside of pipes and do not contact the internal liquid. The technology has inherent advantages over alternate devices including: low-cost installation,

More information

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06... 1 2 BATTERY-OPERATED WATER METER MAG 8000 MAG 8000 is a comprehensive meter which intelligent information and high performance measurement as well as the easy to install concept take cost of ownership

More information

Digital Level Sensor. Consistent accuracy, unparalleled reliability. Answers for energy.

Digital Level Sensor. Consistent accuracy, unparalleled reliability. Answers for energy. Digital Level Sensor Consistent accuracy, unparalleled reliability Answers for energy. 2 Consistent accuracy Unparalleled reliability The Siemens Digital Level Sensor (DLS) is an engineered solution for

More information

Simplified information where and how you want it.

Simplified information where and how you want it. ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator

More information

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUE1010 (Energy) 4/317. Overview

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUE1010 (Energy) 4/317. Overview Siemens AG 2010 Flow Measurement Overview Application FUE1010 is ideally suited to thermal energy / power industry applications, including: hilled water sub-metering Hot water sub-metering ondenser water

More information

Instruction Manual March airanger XPL PLUS

Instruction Manual March airanger XPL PLUS Instruction Manual March 2005 airanger XPL PLUS Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 TABLE OF

More information

Level and Flow Measurement. IMP Range

Level and Flow Measurement. IMP Range Level and Flow Measurement IMP Range IMP IMP Standard 2/3 Wire IMP I.S. The IMP range offers a combined transducer and controller in one self contained unit. Non-contact level measurement of liquids or

More information

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel Series TFXB Ultra Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow measurement transmitter

More information

Remote monitoring and display solutions

Remote monitoring and display solutions siemens.com/sitransrd Remote monitoring and display solutions Instrumentation readings in any location including over the web for around-the-clock monitoring. Answers for industry. Get your instrumentation

More information

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution DATA SHEET Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.:

More information

PowerFlex 400 AC Drive Guide Specification

PowerFlex 400 AC Drive Guide Specification PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M low sensor MAG P Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage

More information

Instruction Manual April milltronics SF500

Instruction Manual April milltronics SF500 Instruction Manual April 2007 milltronics SF500 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.

More information

Dupline Fieldbus Components

Dupline Fieldbus Components Dupline Fieldbus Components Channel Generators/Interfaces Types D390 G300 G396 G39 Standard channel generator. 77 x x 70 Controller and Modbus Interface with built-in GSM Modem (option) or external Radio

More information

Blackbox Controllers:

Blackbox Controllers: Blackbox Controllers: Level measurement made simple Compact low cost intelligent controllers Will operate on all db transducers up to 40m range Solids, powders and liquids level measurement Separation

More information

Supplementary Components WirelessHART products

Supplementary Components WirelessHART products Overview SITRANS AW200 WirelessHART adapter The SITRANS AW200 WirelessHART adapter is a batterypowered communication component, which integrates HART and 4 to 20 ma field devices into a WirelessHART network.

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II i2850 Series The i2850, i2851, and i2853 controllers provide cost-effective DDC control of individual terminal units (e.g. VAV boxes, fan-powered induction units, unit ventilators,

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Enclosures for Remote I/O System I.S. 1

Enclosures for Remote I/O System I.S. 1 STAINLESS STEEL (V2A) STAINLESS STEEL (V4A) POLYESTER RESIN IP66 For Installation in II 2 G EEx e II Increased safety protection Certified according to 94/9EG (ATEX) For Installation in Zone 2 Declaration

More information

Gladiator Admittance Smart Switch Series

Gladiator Admittance Smart Switch Series A Higher Level of Performance Data Sheet Gladiator Admittance Smart Switch Series An All-round Point Level Switch For more information, please visit > www.hawkmeasure.com The is a third generation, state-of-the-art

More information

Level and Flow Measurement. dbi Transducers. HART and Profibus PA Intelligent Transducers

Level and Flow Measurement. dbi Transducers. HART and Profibus PA Intelligent Transducers Level and Flow Measurement dbi Transducers HART and Profibus PA Intelligent Transducers dbi Series Transducers: HART and Profibus PA Ultrasonic Transducers for Level Measurement Features Self-contained

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on Overview SITRNS FUS1010 is the most versatile clamp-on ultrasonic flow display transmitter available today. It can operate in either Wide- Beam Transit time or Reflexor (Doppler) mode, making it suitable

More information

Capacitance level switches LS 210 LS 220

Capacitance level switches LS 210 LS 220 KROHNE 03/2001 7.02374.31.00 GR/PRINTO Capacitance level switches Compact switches for liquids, solids, slurry, foam and interface; outstanding performance for a low price Easy to install, no moving parts,

More information

Siemens AG Continuous level measurement Radar transmitters. Configuration. Installation

Siemens AG Continuous level measurement Radar transmitters. Configuration. Installation Siemens AG 201 Overview Configuration Installation SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including

More information

analytical bulk flow distance FLOW level pressure temperature industrial communication

analytical bulk flow distance FLOW level pressure temperature industrial communication analytical bulk flow distance FLOW level pressure temperature industrial communication LEVELWIZARD II OPEN CHANNEL FLOWMETER The LevelWizard II Open Channel Flowmeter is non-contacting and operates on

More information

Grounding Monitoring Device Series 8485

Grounding Monitoring Device Series 8485 www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI SITRNS F flowmeters Siemens G 2009 Overview Standard volume (net) or mass flowmeters ( standard volume / mass ) Exceptional repeatability is maintained, independent of changes in temperature, density or

More information

MINIRANGER PLUS. Instruction Manual PL-604 June Rev. 1.3

MINIRANGER PLUS. Instruction Manual PL-604 June Rev. 1.3 MINIRANGER PLUS Instruction Manual PL-604 June 2001 MA 33456040 Rev. 1.3 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product

More information

DMT345 and DMT346 Dewpoint Transmitters

DMT345 and DMT346 Dewpoint Transmitters DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662

More information

Gladiator Acoustic Switch Series

Gladiator Acoustic Switch Series A Higher Level of Performance Data Sheet Gladiator Acoustic Switch Series Non-contact Self Cleaning Blocked Chute Detection For more information, please visit > www.hawkmeasure.com Acoustic Cleaning Principle

More information

Technical specification FLUXUS F501. Ultrasonic measurement of water flow

Technical specification FLUXUS F501. Ultrasonic measurement of water flow Technical specification Ultrasonic measurement of water flow Permanently installed ultrasonic clamp-on system for flow measurement of water Features Non-invasive flow measurement with high measuring accuracy

More information