Section 6. Surge Protective Devices (SPDs) Table of Contents. Externally Mounted Surge Protective Devices
|
|
- Meredith McBride
- 5 years ago
- Views:
Transcription
1 Table of Contents Section (SPDs) Commercial Applications EMA/EBA SPDs, pages -2, -3, & -4 Externally Mounted External Modular SPDs EMA SPDs -2 External Modular L-L Enhanced SPDs -3 External Brick Assembly SPDs EBA SPDs -3 Replacement Modules -4 Internally Mounted SPDs New Construction/Factory Assembled Panelboards & Switchboards, page -7 Retrofit, page -7 Panelboards Refer to 9-1 Switchboards and Switchgear Refer to 11-1 Model Motor Control Centers Refer to 17-1 IPaCS Refer to 10-1 Busway 12-1 Internally Mounted SPDs Retrofit/Ready to Install Internally Mounted SPD Retrofit -7 Surgelogic SurgeLoc for NQ Panelboards -8 OEM/Assembler Kits -8 Nipple-Mounted SDSA350 SPDs -5 HWA SPDs -5 SDSA1175 SPDs - Mounting Brackets and Flush Mount Kits -5 XR SPDs -5 Surgelogic SurgeLoc, page -8 Residential & Light Commercial Applications Residential Whole House Whole House SPDs -9 Whole House Accessories -9 QO, NQ, and Homeline Loadcenter SPDs -9 Nipple Mounted SPDs, page -5 Whole House SPDs, page -9 QO/HOM SPDs, page Schneider Electric -1
2 Externally Mounted Class 1310 / Refer to Catalog 1310CT Externally Mounted Surgelogic offers a full range of externally mounted SPDs. These units are designed to provide surge suppression from service entrance panels to point-of-use equipment. US and Canadian UL Listed to UL rd Edition and UL th Edition. Complies with requirements of NEC Article 285 and CSA 22.2 No. 8-M198 as appropriate. Complies with UL 9A 12th Edition Master Label requirements for Lightning Protection Systems. 10 year product warranty 10 modes of protection 200 ka SCCR EMI/RFI filtering Audible alarm with enable/disable switch, dry contacts, and surge counter standard Indicator LEDs; normal (green) and fault condition (red) for each phase UL 1449 Type 2 (or Type 1 with optional suffix in catalog number) External SPD Options: Sine Wave Tracking Module. Sine Wave Tracking (SWT) circuitry provides enhanced EMI/RFI filtering of -54 db at 100 khz and establishes the power surge clamping window relative to the sine wave voltage to increase performance at distribution and branch panel applications. Type 1. UL 1449 Type 1 SPDs can be located at any point in the electrical system, on the line or load side of the equipment overcurrent device. Integral Switch. The integral switch provides a mechanical means to electrically isolate the entire surge suppressor before opening the enclosure door to facilitate servicing of the unit s components. Remote Monitor. This option displays the alarm status of the surge protective device up to 1000 feet from the unit. Flush Mount Kits. Flush mounting kits can be used on ka EMA and EBA series devices. with integral switch require a 20 inch flush mounting collar. External Modular Assembly (EMA) SPDs EMA SPD products feature a design based on individual phase modules for a flexible, cost effective way to achieve superior surge suppression at every level of the electrical distribution system. Modularity results in lower life cycle costs and fast, easy service or replacement. External Modular SPD with Integral Switch External Modular SPD with Sine Wave Tracking Module External Modular High-Resistance Ground SPD Table.1: EMA SPDs Service Current Rating per Phase (ka) d 4-wire + ground abd 4-wire + groundd High-leg 240 V, 3-phase, 4-wire + ground bcd d High-Resistance Ground 480 V, 3-phase,, 4-wire + ground bd d High-Resistance Ground NEMA 3R NEMA 4X Stainless Steel 120 TVS1EMA12A( ) TVS1EMA12S( ) TVS1EMA1A( ) TVS1EMA1S( ) TVS1EMA24A( ) TVS1EMA24S( ) TVS1EMA32A( ) TVS1EMA32S( ) TVS1EMA48A( ) TVS1EMA48S( ) TVS2EMA12A( ) TVS2EMA12S( ) TVS2EMA1A( ) TVS2EMA1S( ) TVS2EMA24A( ) TVS2EMA24S( ) TVS2EMA32A( ) TVS2EMA32S( ) TVS2EMA48A( ) TVS2EMA48S( ) TVS3EMA12A( ) TVS3EMA12S( ) TVS3EMA1A( ) TVS3EMA1S( ) TVS3EMA24A( ) TVS3EMA24S( ) TVS3EMA32A( ) TVS3EMA48A( ) TVSEMA10A( ) TVSEMA10S( ) TVSEMA12A( ) TVSEMA12S( ) TVSEMA1A( ) TVSEMA1S( ) TVSEMA20A( ) TVSEMA20S( ) TVSEMA24A( ) TVSEMA24S( ) TVSEMA32A( ) TVSEMA32S( ) TVSEMA48A( ) TVSEMA48S( ) TVS4EMA12A( ) TVS4EMA12S( ) TVS4EMA1A( ) TVS4EMA1S( ) TVS4EMA24A( ) TVS4EMA24S( ) TVS4EMA32A( ) TVS4EMA32S( ) TVS4EMA48A( ) TVS4EMA48S( ) TVS4HEMA10A( ) TVS4HEMA10S( ) TVS4HEMA12A( ) TVS4HEMA12S( ) TVS4HEMA1A( ) TVS4HEMA1S( ) TVS4HEMA20A( ) TVS4HEMA20S( ) TVS4HEMA24A( ) TVS4HEMA24S( ) TVS4HEMA32A( ) TVS4HEMA32S( ) TVS4HEMA48A( ) TVS4HEMA48S( ) TVS5EMA10A( ) TVS5EMA10S( ) TVS5EMA12A( ) TVS5EMA12S( ) TVS5EMA1A( ) TVS5EMA1S( ) TVS5EMA20A( ) TVS5EMA20S( ) TVS5EMA24A( ) TVS5EMA24S( ) TVS5EMA32A( ) TVS5EMA32S( ) TVS5EMA48A( ) TVS5EMA48S( ) TVS8EMA12A( ) TVS8EMA12S( ) TVS8EMA1A( ) TVS8EMA1S( ) TVS8EMA24A( ) TVS8EMA24S( ) TVS8EMA32A( ) TVS8EMA32S( ) TVS8EMA48A( ) TVS8EMA48S( ) TVS8HEMA10A( ) TVS8HEMA10S( ) TVS8HEMA12A( ) TVS8HEMA12S( ) TVS8HEMA1A( ) TVS8HEMA1S( ) TVS8HEMA18A( ) TVS8HEMA18S( ) TVS8HEMA20A( ) TVS8HEMA20S( ) TVS8HEMA24A( ) TVS8HEMA24S( ) TVS8HEMA32A( ) TVS8HEMA32S( ) TVS9EMA10A( ) TVS9EMA10S( ) TVS9EMA12A( ) TVS9EMA12S( ) V, 3-phase, 10 TVS9EMA1A( ) TVS9EMA1S( ) , 180 TVS9EMA18A( ) TVS9EMA18S( ) TVS9EMA20A( ) TVS9EMA20S( ) TVS9EMA24A( ) TVS9EMA24S( ) TVS9EMA32A( ) TVS9EMA32S( ) a 208Y/120 series also applies to the following voltage 220Y/127. b Can be used on 4-wire or 3-wire grounded neutral system. c 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240. d Do not use on ungrounded systems. Systems must be solidly grounded. External Modular Options ( ) (1) UL 1449 Type (I) e Integral Switch (SWT) Sine Wave Tracking Module (not applicable for or HRG) (I1) e UL 1449 Type 1 and Integral Switch (SWT1) UL 1449 Type 1 and Sine Wave Tracking Module (not applicable for or HRG) (ISWT) e Integral Switch and Sine Wave Tracking Module (not applicable for or HRG) (ISWT1) e UL 1449 Type 1, Integral Switch and Sine Wave Tracking Module (not applicable for or HRG) Accessory Description Remote Monitor TVS12RMU inch Flush Mount Kit TVS12FMK inch Flush Mount Kit TVS20FMK e Not available in stainless steel for 320 and 480 ka Schneider Electric DE1B Discount
3 External Device Refer to Catalog 71CT9701 External Modular L-L Enhanced SPDs External modular Line-to-Line (L-L) Enhanced SPDs are parallel systems that provide 10 modes of protection and enhanced, discrete L-L suppression paths. Table.2: Service L-L Enhanced SPDs Current Rating per Phase (ka) NEMA 3R NEMA 4X Stainless Steel 120 TVS2MEMA12A( ) TVS2MEMA12S( ) wire + ground fh 180 TVS2MEMA18A( ) TVS2MEMA18S( ) TVS2MEMA27A( ) TVS2MEMA27S( ) TVS2MEMA3A( ) TVS2MEMA3S( ) TVS4MEMA12A( ) TVS4MEMA12S( ) wire + ground gh 180 TVS4MEMA18A( ) TVS4MEMA18S( ) TVS4MEMA27A( ) TVS4MEMA27S( ) TVS4MEMA3A( ) TVS4MEMA3S( ) f 208Y/120 series also applies to the following voltage 220Y/127. g 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240. h Do not use on ungrounded systems. Systems must be solidly grounded. External Modular L-L Enhanced SPD with Sine Wave Tracking Module External Brick Assembly SPD with Integral Switch External Modular L-L Enhanced Options ( ) (1) UL 1449 Type (SWT) Sine Wave Tracking Module (SWT1) UL 1449 Type 1 and Sine Wave Tracking Module Accessory Description Remote Monitor TVS12RMU inch Flush Mount Kit TVS20FMK External Brick Assembly SPDs External Brick Assembly (EBA) SPD products consist of a consolidation of phase modules into one solid brick casting and offered at a competitive price for those who want superior surge suppression on a limited budget. Table.3: Service 120/240 V,1-phase, d 4-wire + ground abd 4-wire + ground d High-leg 4-wire + ground bcd EBA SPDs Current Rating per Phase (ka) NEMA 3R NEMA 4X Stainless Steel 120 TVS1EBA12A( ) TVS1EBA12S( ) TVS1EBA1A( ) TVS1EBA1S( ) TVS1EBA24A( ) TVS1EBA24S( ) TVS2EBA12A( ) TVS2EBA12S( ) TVS2EBA1A( ) TVS2EBA1S( ) TVS2EBA24A( ) TVS2EBA24S( ) TVS3EBA12A( ) TVS3EBA12S( ) TVS3EBA1A( ) TVS3EBA1S( ) TVS3EBA24A( ) TVS3EBA24S( ) TVS4EBA12A( ) TVS4EBA12S( ) TVS4EBA1A( ) TVS4EBA1S( ) TVS4EBA24A( ) TVS4EBA24S( ) TVS8EBA12A( ) TVS8EBA12S( ) wire + ground bd 10 TVS8EBA1A( ) TVS8EBA1S( ) TVS8EBA24A( ) TVS8EBA24S( ) a 208Y/120 series also applies to the following voltage 220Y/127. b Can be used on 4-wire or 3-wire grounded neutral system. c 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240. d Do not use on ungrounded systems. Systems mst be solidly grounded. Remote Monitor External Brick Assembly Options ( ) (1) UL 1449 Type (I) Integral Switch (SWT) Sine Wave Tracking Module (not applicable for ) (I1) UL 1449 Type 1 and Integral Switch (SWT1) UL 1449 Type 1 and Sine Wave Tracking Module (not applicable for ) (ISWT) Integral Switch and Sine Wave Tracking Module (not applicable for ) 1, (ISWT1) UL 1449 Type 1, Integral Switch and Sine Wave Tracking Module (not applicable for ) 1, Accessory Description Remote Monitor TVS12RMU inch Flush Mount Kit TVS12FMK inch Flush Mount Kit TVS20FMK Schneider Electric PE4 PE7 PE1A Discount -3
4 Replacement Modules All modules and brick assemblies are US and Canadian UL Recognized to UL rd Edition and UL th Edition. Complies with requirements of NEC Article 285 and CSA C22.2 No. 8-M198 as appropriate. e For UL 1449 Type 1 Modules, add suffix (1). Example: MA1IMA121 MA Replacement Module Replacement Module HRG Replacement Module EBA Replacement Module MA Replacement Module L-L Enhanced Replacement Module Table.4: a b System 4-wire + ground a 120/240 V, 3-phase, 4-wire + ground b High-Leg 240 V, 3-phase, 4-wire + ground c c High-Resistance Ground 480 V, 3-phase, 4-wire + ground High-Resistance Ground EMA Replacement Modules Replacement Modules Refer to Catalog 71CT Catalog Numbers Current Rating (ka) Phase A Phase B Phase C 120 MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA3IMA MA1IMA MA1IMA MA3IMA MA1IMA MA1IMA MA3IMA MA1IMA MAIMA MAIMA MAIMA MAIMA MAIMA MAIMA MAIMA MAIMA MAIMA MAIMA MAIMA MAIMA MAIMA MAIMA MAIMA MA4IMA MA4IMA MA4IMA MA4IMA MA4IMA MA4IMA MA4IMA MA4IMA MA4IMA MA4IMA10H MA4IMA10H MA4IMA10H MA4IMA12H MA4IMA12H MA4IMA12H MA4IMA1H MA4IMA1H MA4IMA1H MA4IMA20H MA4IMA20H MA4IMA20H MA4IMA24H MA4IMA24H MA4IMA24H MA5IMA MA5IMA MA5IMA MA5IMA MA5IMA MA5IMA MA5IMA MA5IMA MA5IMA MA5IMA MA5IMA MA5IMA MA5IMA MA5IMA MA5IMA MA8IMA MA8IMA MA8IMA MA8IMA MA8IMA MA8IMA MA8IMA MA8IMA MA8IMA MA8IMA10H MA8IMA10H MA8IMA10H MA8IMA12H MA8IMA12H MA8IMA12H MA8IMA1H MA8IMA1H MA8IMA1H MA8IMA18H MA8IMA18H MA8IMA18H MA9IMA MA9IMA MA9IMA MA9IMA MA9IMA MA9IMA MA9IMA MA9IMA MA9IMA V, 3-phase, 180 MA9IMA MA9IMA MA9IMA a 208Y/120 series also applies to the following voltage 220Y/127. b High-leg delta (Phase B modules are different than Phase A and Phase C modules). c 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240. Table.5: EBA Replacement Modules System Current Rating (ka) Catalog Numbers 120 MA1IBA MA1IBA MA1IBA MA2IBA MA2IBA wire + ground a 240 MA2IBA MA3IBA wire + ground b 10 MA3IBA High-leg 240 MA3IBA MA4IBA wire + ground c 10 MA4IBA MA4IBA MA8IBA wire + ground 10 MA8IBA MA8IBA a 208Y/120 series also applies to the following voltage 220Y/127. b High-leg delta (Phase B modules are different than Phase A and Phase C modules). c 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240. Table.: L-L Enhanced MA (L-N, L-G) Replacement Modules System Catalog Numbers Current Rating (ka) Phase A Phase B Phase C 4-wire + ground a 120 MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA1IMA MA4IMA MA4IMA MA4IMA MA4IMA MA4IMA MA4IMA MA4IMA MA4IMA MA4IMA wire + ground b 30 MA4IMA MA4IMA MA4IMA a 208Y/120 series also applies to the following voltage 220Y/127. b 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240. Table.7: L-L Enhanced (L-L) Replacement Modules System Catalog Numbers Current Rating (ka) Phase A Phase B Phase C 4-wire + ground a 120 MA2IMA40LL MA2IMA40LL MA2IMA40LL MA2IMA0LL MA2IMA0LL MA2IMA0LL MA2IMA90LL MA2IMA90LL MA2IMA90LL MA2IMA12LL MA2IMA12LL MA2IMA12LL MA4IMA40LL MA4IMA40LL MA4IMA40LL MA4IMA0LL MA4IMA0LL MA4IMA0LL MA4IMA90LL MA4IMA90LL MA4IMA90LL wire + ground b 30 MA4IMA12LL MA4IMA12LL MA4IMA12LL Y/120 series also applies to the following voltage 220Y/ Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/ Schneider Electric PE4 PE7 PE1A Discount
5 HWA Series Nipple Mounted SPDs Class 71 / Refer to Catalog 71CT9701 HWA Surgelogic HWA surge protective devices are compact, nipple-mounted parallel-connected surge suppressors that come in a variety of voltage configurations, including. A surge suppression path is provided for each mode, and the product is rated NEMA Type 4X. Internal diagnostics continuously monitor the device status. US and Canadian UL Listed as a Type 2 SPD to UL rd Edition and UL th Edition. Complies with requirements of NEC Article 285 and CSA C22.2 No. 8-M198 as appropriate. Complies with UL 9A 12th Edition Master Label requirements for Lightning Protection Systems. LEDs indicate operational status Short circuit current rating 200 ka Suitable for indoor and outdoor applications (NEMA Type 4X rated) Convenient side-nipple mounting Compact design provides easy mounting inside or outside the equipment cabinets -54 db EMI/RFI filtering Sine wave tracking Audible alarm indicates loss of suppression (does not contain alarm enable/disable switch) Dry contacts Optional flush-mount kit TVSHWAFMK Table.8: HWA Service Current Rating per Phase (ka) NEMA 4X 50 TVS1HWA50X d 80 TVS1HWA80X TVS1HWA10X TVS2HWA50X wire + ground abd 80 TVS2HWA80X TVS2HWA10X TVS3HWA50X wire + groundd 80 TVS3HWA80X High-leg 100 TVS3HWA10X V, 3-phase, 50 TVSHWA50X TVSHWA80X TVSHWA10X TVS4HWA50X wire + ground acd 80 TVS4HWA80X TVS4HWA10X V, 3-phase, 50 TVS5HWA50X TVS5HWA80X TVS5HWA10X TVS8HWA50X wire + groundd 80 TVS8HWA80X TVS8HWA10X V, 3-phase, 50 TVS9HWA50X TVS9HWA80X TVS9HWA10X a Can be used on 4-wire or 3-wire grounded neutral system. b 208Y/120 series also applies to the following voltage 220Y/127. c 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240. d Do not use on ungrounded systems. Systems must be solidly grounded. Nipple-Mounted XR The XR SPD provides high-quality surge suppression in a compact and versatile package. This product is ideal for panel builders as well as manufacturers and integrators of instrumentation cabinets for industrial, commercial, and residential applications for single-phase power systems. US and Canadian UL Listed as Type 1 SPD to UL rd Edition. Complies with requirements of NEC Article 285, CSA , and CSA C22.2 No. 8-M198 as appropriate. XR Series LEDs indicate operational status Short circuit current rating 25 ka Convenient side nipple mounting Suitable for indoor and outdoor applications (NEMA Type 4X rated) Optional flush mount kit TVSXRFMK Table.9: XR Nipple-Mounted System Current Rating per Phase (ka) 50 TVS120XR50S TVS120XR80S QOSAMK TVSXRFMK Mounting Brackets and Flush Mount Kits The nipple products shown in this catalog provide a convenient means of incorporating surge suppression within a new or existing cabinet. The mounting bracket and flush-mount kits are designed for easy mounting of nipple products. Table.10: Mounting Bracket for Enclosures Description Mounting bracket for QO and Homeline load centers and other enclosures QOSAMK Flush-mount kit for XR SPDs TVSXRFMK Flush-mount kif for HWA SPDs TVSHWAFMK Schneider Electric DE1B Discount -5
6 SDSA1175 and SDSA350 SPDs Class 71 / Refer to Catalog 71CT SDSA1175 SDSA1175 and SDSA350 SDSA1175 are designed and listed for indoor or outdoor installation and surge suppression for single-phase three-wire 120/240 Vac or two-wire 120 Vac 0 Hz electrical services. This product is ideal for panel builders as well as manufacturers and integrators of instrumentation cabinets for industrial, commercial, and residential applications for single-phase power systems. Two SDSA1175 surge protection devices can be installed to provide suppression for 208Y/120 Vac three-phase four-wire services. SDSA350 SPDs are designed and listed for indoor or outdoor installation and surge suppression for threephase grounded electrical services up to 00 Vac, including delta services (SDSA350D). The SDSA350 series is used extensively in service entrance panels to provide an efficient and economical means of surge suppression. US and Canadian UL Listed as Type 1 SPD to UL rd Edition. Complies with requirements of NEC Article 285, CSA , and CSA C22.2 No. 8-M198 as appropriate. LED indicates operational status Short circuit current rating 25 ka Suitable for indoor and outdoor applications (NEMA Type 4X rated) Convenient back-nipple mounting SDSA350 SDSA350D Table.11: SDSA1175 and SDSA350 System Current Rating per Phase (ka) SDSA wire 3 SDSA1175a V, 1-phase, 2-wire 3 SDSA1175T a SDSA Vac Maximum, 3-phase, 4-wireb 40 SDSA350 c Vac Maximum, 3-phase, 3-wire 40 SDSA350D c a See Table.10 for QOSAMK mounting kit for installation in QO load centers. b Do not use on ungrounded systems. Systems must be solidly grounded. c See Table.10 for QOSAMK mounting kit for installation in QO load centers Schneider Electric
7 Internally Mounted Refer to Catalog 71CT9701 Internally Mounted Internally mounted surge protective devices are installed integrally to systems for service entrance and branch panel surge suppression. Internally mounted SPDs installed next to supply busses provide maximum performance inside Square D systems. Built-in performance is the best way to ensure cost effective power quality (especially important for critical power facilities). US and Canadian UL Recognized as a Type 2 (or 1 with optional suffix in catalog number) SPD Component Assembly to UL rd Edition and UL th Edition. Complies with requirements of NEC Article 285 and CSA C22.2 No. 8-M198 as appropriate. Complies with UL 9A 12th Edition Master Label requirements for Lightning Protection Systems. Internally Mounted New Construction / Factory Assembled Factory installed integral/internal Surgelogic SPD products make adding surge suppression to new construction projects easy. Refer to the sections listed below to identify the correct product for your application or contact Surgelogic TAG at for assistance. Panelboards Refer to Section 9 Switchboards and Switchgear Refer to Section 11 Motor Control Centers Refer to Section 17 Integrated Power and Control Centers Refer to Section 10 NF NQ PZ4 QED MCC IPAC2 Busway Refer to Section 12 I-Line Surgelogic SPD Unit QMB Surgelogic SPD Unit Busway Surgelogic SPD Unit MCC Surgelogic SPD Unit Internally Mounted Retrofit/Ready to Install To ensure high-performance surge suppression at critical power locations, a variety of Surgelogic products have been designed specifically for retrofitting into commonly used Square D systems. The QMB fusible switch, in. MCC bucket, I-Line and Busway plug-on units come with the SPD factory-installed. Retrofitting SPD units into I-Line, QMB, MCC, and Busway applications is simple. Audible alarm with enable/disable switch, dry contacts, and surge counter standard. 200 ka SCCR Indicator LEDs EMI/RFI filtering Table.12: Internally Mounted Retrofit / Ready To Install 4-wire + ground fg 4-wire + ground High-leg 240 V, 3-phase,, 4-wire + ground fh Surge Current I-Line Branch Units a QMB Branch Units b Busway Units Model MCC Units c Rating e d 120 ka HL1IMA12C( ) HR1IMA12C( ) QMB1IMA ka HL1IMA1C( ) HR1IMA1C( ) QMB1IMA ka HL1IMA24C( ) HR1IMA24C( ) QMB1IMA ka HL2IMA12C( ) HR2IMA12C( ) QMB2IMA MCC2IMA ka HL2IMA1C( ) HR2IMA1C( ) QMB2IMA PIU2IMA MCC2IMA ka HL2IMA24C( ) HR2IMA24C( ) QMB2IMA PIU2IMA MCC2IMA ka HL3IMA12C( ) HR3IMA12C( ) QMB3IMA MCC3IMA ka HL3IMA1C( ) HR3IMA1C( ) QMB3IMA PIU3IMA MCC3IMA ka HL3IMA24C( ) HR3IMA24C( ) QMB3IMA PIU3IMA MCC3IMA ka HLIMA12C( ) HRIMA12C( ) ka HLIMA1C( ) HRIMA1C( ) ka HLIMA24C( ) HRIMA24C( ) ka HL4IMA12C( ) HR4IMA12C( ) QMB4IMA MCC4IMA ka HL4IMA1C( ) HR4IMA1C( ) QMB4IMA PIU4IMA MCC4IMA ka HL4IMA24C( ) HR4IMA24C( ) QMB4IMA PIU4IMA MCC4IMA ka HL4HIMA12C( ) HR4HIMA12C( ) h 10 ka HL4HIMA1C( ) HR4HIMA1C( ) High-Resistance Ground 240 ka HL4HIMA24C( ) HR4HIMA24C( ) V, 3-phase,, 4-wire + ground f 120 ka HL5IMA12C( ) HR5IMA12C( ) ka HL5IMA1C( ) HR5IMA1C( ) ka HL5IMA24C( ) HR5IMA24C( ) ka HR8IMA12C( ) QMB8IMA MCC8IMA ka HR8IMA1C( ) QMB8IMA PIU8IMA MCC8IMA ka HR8IMA24C( ) QMB8IMA PIU8IMA MCC8IMA ka HR8HIMA12C( ) , 10 ka HR8HIMA1C( ) High-Resistance Ground 180 ka HR8HIMA18C( ) V, 3-phase,, a b c 120 ka HR9IMA12C( ) ka HR9IMA1C( ) ka HR9IMA18C( ) d PE4 Discount. g 208Y/120 series also applies to the following e PE7 Discount. voltage 220Y/127. f Can be used on 4-wire or 3-wire grounded h 480Y/277 series applies to the following voltages neutral system. 380Y/220, 400Y/230, and 415Y/240. Requires 13.5-inch mounting height. Requires 9-inch mounting height. Requires -inch mounting height. ( ) For a Type 1 SPD, add a 1 suffix to the catalog number Schneider Electric PE4 PE7 PE1A Discount -7
8 OEM Kit Surgelogic Refer to Catalog 71CT9701 Surgelogic SurgeLoc for NQ Panelboards Table.13: Internally Mounted Retrofit / Ready to Install a b c 4-wire + groundab 240Y/120 V, 3-phase, 4-wire + ground High-leg Can be used on 4-wire or 3-wire grounded neutral system. 208/120 series also applies to the following voltage 220Y/127. Requires 12 circuit positions ( adjacent mounting spaces per side). NQ Panelboard Units SurgLocc Surge Current Rating 80 ka SSP01BIA08PBQ ka SSP01BIA10PBQ ka SSP01BIA12PBQ ka SSP01BIA1PBQ ka SSP01BIA20PBQ ka SSP01BIA24PBQ ka SSP02BIA08PBQ ka SSP02BIA10PBQ ka SSP02BIA12PBQ ka SSP02BIA1PBQ ka SSP02BIA20PBQ ka SSP02BIA24PBQ ka SSP03BIA08PBQ ka SSP03BIA10PBQ ka SSP03BIA12PBQ ka SSP03BIA1PBQ ka SSP03BIA20PBQ ka SSP03BIA24PBQ OEM/Assembler Kits Surgelogic OEM/assembler kits allow manufacturers to add industry-leading surge suppression directly to customized equipment. Manufacturers benefit from shorter wire lengths that optimize the clamping voltage of the SPD. Products come with a backplanemounted SPD, mounting hardware and diagnostic display with 3-inch cables. Audible alarm, silence switch, remote monitoring contacts, and surge counter are standard. Available as UL 1449 Type 2 (or 1 with optional suffix in catalog number). US and Canadian UL Recognized to UL rd Edition and UL th Edition. Complies with requirements of NEC Article 285 and CSA 22.2 No. 8-M198 as appropriate. Complies with UL 9A 12th Edition Master Label requirements for Lightning Protection Systems. Table.14: OEM/Assembler Kits Service Current Rating per Phase (ka) 4-wire + ground bc 4-wire + ground High-leg 240 V, 3-phase, bd 4-wire + ground bd bd High-Resistance Ground 480 V, 3-phase, 4-wire + ground b b High Resistance Ground a 120 TVS1IMA12O( ) TVS1IMA1O( ) TVS1IMA24O( ) TVS2IMA12O( ) TVS2IMA1O( ) TVS2IMA24O( ) TVS3IMA12O( ) TVS3IMA1O( ) TVS3IMA24O( ) TVSIMA12O( ) TVSIMA1O( ) TVSIMA24O( ) TVS4IMA12O( ) TVS4IMA1O( ) TVS4IMA24O( ) TVS4HIMA12O( ) TVS4HIMA1O( ) TVS4HIMA24O( ) TVS5IMA12O( ) TVS5IMA1O( ) TVS5IMA24O( ) TVS8IMA12O( ) TVS8IMA1O( ) TVS8IMA24O( ) TVS8HIMA12O( ) TVS8HIMA1O( ) TVS8HIMA18O( ) TVS9IMA12O( ) TVS9IMA1O( ) V, 3-phase, 180 TVS9IMA18O( ) ( ) For a Type 1 SPD, add a 1 suffix to the catalog number. a Note the last character of the catalog number is the letter O, not a zero. b Can be used on 4-wire or 3-wire grounded neutral system. c 208Y/120 series also applies to the following voltage 220Y/127. d 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/ Schneider Electric OE1A Discount
9 Residential SPDs Class 71 Refer to Catalog 71CT9701 Residential Whole House Surge Protective HEPD80MKF SDSB80111 HEPD80 Whole House Whole House devices are designed to deliver surge suppression that addresses the entire home. AC modules are connected to the circuit breaker load center and provide suppression for all equipment connected to the power system. Whole House systems incorporate AC modules as well as modules for other metallic lines coming into the home including telephone/dsl and coaxial video/data. US and Canadian UL Listed as Type 2 SPD to UL rd Edition. Complies with requirements of NEC Article 285, CSA , and CSA C22.2 No. 8-M198 as appropriate. Telephone and coaxial video modules US and Canadian UL Recognized to UL 497A 4th Edition and UL 497B 4th Edition. 120/240 Vac, 80 ka/phase AC surge suppression LED status indicators for AC surge suppression Telephone surge suppression module supports four lines with tool-less Insulation Displacement Connectors (IDC) Coaxial surge suppression module supports one line of video/data Table.15: Whole House Description Included Modules Whole House NEMA 1 AC, Telephone, Coax SDSB Home Electronics Protective Device AC HEPD Whole House Accessories Add additional surge suppression or replace existing modules in Whole House products. Coaxial and telephone modules: US and Canadian UL Recognized to UL 497A 4th Edition and UL 497B 4th Edition. AC Module: US and Canadian UL Listed as Type 1 SPD to UL rd Edition. Complies with requirements of NEC Article 285, CSA , and CSA C22.2 No. 8-M198 as appropriate. Table.1: Accessories Description Flush Mount Kit for HEPD80 HEPD80MKF QO, NQ, and Homeline Load Center Square D load center surge protective devices are easy to install plug-in units that install as quickly as a standard circuit breaker. The surge suppressors use two pole spaces in a QO or Homeline load center, or NQ panelboard. US and Canadian UL Listed as Type 2 SPD to UL rd Edition. Complies with requirements of NEC Article 285, CSA , and CSA C22.2 No. 8-M198 as appropriate. QO2175SB for QO load centers, combination devices, and NQ panelboards HOM2175SB for Homeline load centers and combination devices Plug-on design requires two pole spaces LED indicates operational status 22.5 ka per phase Table.17: QO, NQ, and Homeline Load Center Description QO Surgebreaker for QO and NQ QO2175SB Homeline Surgebreaker HOM2175SB QO2175SB HOM2175SB 2012 Schneider Electric DE1B Discount -9
10 Residential SPDs Class 71 Refer to Catalog 71CT Schneider Electric DE1B Discount
Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/
Surgelogic Surge Protective Devices (SPDs) Residential Catalog 6671CT9701R08/12 2012 CONTENTS Whole House Surge Protective Devices (SPDs).................... 3 SDSB1175C / SDSB1175CB Whole House SPDs..................4
More informationInternal Modular SPDs
Internal Modular SPDs Square D Internally Mounted Protective Devices Square D TM brand logic TM internal modular Protective Devices (SPDs) deliver specification grade performance for service entrance or
More informationI-Line SPDs Square D TM Internally Mounted Surge Protective Devices
Square D TM Internally Mounted Protective Devices Square D TM brand logic TM I-Line Protective Devices (SPDs) deliver specification grade performance for service entrance or critical branch panel applications.
More informationSurgelogic Surge Protective Devices LC, XR, and XW Series
Surgelogic Surge Protective Devices LC, XR, and XW Series Catalog 1311CT0101R6/07 2007 Class 1311 CONTENTS Description..............................................Page Product Description...........................................
More informationSurgelogic Surge Protective Device I-Line Plug-On Unit Series
Surgelogic Surge Protective Device I-Line Plug-On Unit Series Catalog 1310CT0201R5/07 2007 Class 1310 CONTENTS Description Page Product Description.................................................. 2 Application
More informationSurgelogic Surge Protective Devices (SPDs)
1 Surgelogic Surge Protective Devices (SPDs) ANSI/IEEE C62.41.1, C62.41.2 & C62.45 Surge Performance Testing Test performance values contained within this document are representative of Square D brand
More informationSection 6. Surge Protective Devices. Table of Contents. Externally Mounted Surge Protective Devices
Tle of Contents Setion Surge Protetive Commeril Applitions Externlly Mounted Surge Protetive Externl Modulr SPDs EMA SPDs -2 Externl Modulr L-L Enhned SPDs -3 Externl Brik Assemly SPDs EBA SPDs -3 Replement
More informationSurge Protective Devices
Surge Protetive Devies Tle of Contents Commeril Applitions EMA/EBA SPDs Contents Desription Pge Externlly Mounted Surge Protetive Devies Externl Modulr SPDs EMA SPDs 2 Externl Modulr L-L Enhned SPDs 3
More informationPanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards
PanelFAST Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards Whether you planned ahead or have an unexpected project, why wait? You should expect
More informationSquare D Whole House Surge Protection. Advanced appliance and electronics protection from surge damage
Square D Whole House Surge Protection Advanced appliance and electronics protection from surge damage Surges come from many different sources and can cause thousands of dollars in damage. The cost of surge
More informationSECTION SURGE PROTECTIVE DEVICES
SECTION 16289 PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this
More informationEaton s SPD Series for integration into electrical distribution equipment
Technical Data TD01006E Supersedes August 2009 Eaton s SPD Series for integration into electrical distribution equipment Contents Description Page Introduction....2 Applications....2 Features....2 Standards
More informationInstruction Bulletin Boletín de instrucciones Directives d'utilisation , Rev. 02, 03/2016
Surgelogic EMA Series Surge Protective Devices (SPDs) Dispositivos de protección contra sobretensiones transitorias (SPD) Dispositifs de protection contre les surtensions transitoires (SPD) Instruction
More informationSurge Protection Devices (SPD)
TPS3 03 TPS3 03 is a UL 1449 3rd Edition, cul 50 ka Type 1 (Type cul) compact Surge Protective Device. For cul applications, the TPS3 03 can be used as a secondary surge or lighting arrestor alternative
More information2.1. SPD, Power Conditioning, PF Capacitors and Harmonic Filters. Contents Description. Introduction. Surge Protection and Power Conditioning
.1 Industrial and Commercial Surge Protection Introduction Industrial and Commercial Surge Protection SPD Series for Integration into Electrical Distribution Equipment SPD Series for Mounting External
More informationLiebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System
Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe
More informationSquare D Homeline Load Centers and Circuit Breakers. Engineered for value
Square D Homeline Load Centers and Circuit Breakers Engineered for value TM From the Square D brand you know and trust, Homeline Load Centers are engineered for value, reliability, and innovation. The
More informationPower-Style QED-2, Series 2 Low Voltage Switchboards
Power-Style QED-2, Series 2 Low Voltage Switchboards Catalog 2742CT1001 (Addendum to 2742CT9501R12/09) 2010 Class 2742 CONTENTS Description............................................. Page Features...................................................
More informationClipper Power System Visor Series
Clipper Power System Visor Series Technical Data Supersedes TD.37B.21.T.E pages 1-8 dated October 2001 Description Page Applications.................................................. 2 General Description............................................
More informationSURGELOGIC TM. Surge Protective Device Transient Voltage Surge Suppressor (TVSS) XGA, XT, XF, XP Series. Class Schneider Electric Brands
SURGELOGI TM Surge Protective Device Transient Voltage Surge Suppressor () XG, XT, XF, XP Series lass 1310 OTETS Description Page Product Descriptions..................................................
More informationBSPD Surge Protective Devices
BUSSMANN Supersedes December 2016 SERIES BSPD Surge Protective Devices High capacity Type 1 and Type 2 SPDs for overvoltage protection on Contents Description Page Introduction 2 Applications 2 Features
More informationSurge Protective Devices (SPD)
Surge Protective Devices (SPD) SPEEDFAX TM 2017 Section c o n t e n t s Scan to connect online to the most up-todate version of this Section of SPEEDFAX. Siemens TPS3 family of hardwired Surge Protective
More informationSECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.
SECTION 26 43 00 SURGE PROTECTION DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment. 1.2 DEFINITIONS A. ATS:
More informationHUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)
HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...
More informationGE TR7000 Series Wall Mounted Surge Protective Device (SPD)
Digital Energy Power Quality Product Specification GE TR7000 Series Wall Mounted Surge Protective Device (SPD) Medium Exposure - Rated 65kA to 100kA Per STANDARDS UL 1449 3rd Edition UL 1283 UL 96A CSA
More informationDIVISION 16 SECTION Surge Protective Device Submittal (SPD)
DIVISION 16 SECTION 16289 Surge Protective Device Submittal (SPD) PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary
More informationNEMA 1 / IP40 metal housing. Compact design
Main range & features VALVETRAB SQ... NEMA 4X / IP66 housing available VALVETRAB SQ SP Acoustic alarm VALVETRAB SQ CC Remote indication contact Universal installation options Exchangeable structure NEMA
More informationSquare D QO Load Centers and Circuit Breakers. The leader for safe, reliable, and innovative solutions
Square D QO Load Centers and Circuit Breakers The leader for safe, reliable, and innovative solutions TM QO Load Centers are built on the Square D reputation for reliability, innovation, and circuit protection
More informationSurg Sur e P ot r ection
Surge Protection Power Disturbances Lightning and fluctuations in utility power (caused by grid switching, for example) are often assumed to be the main sources of power disturbances. However, the overwhelming
More information1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.
SECTION 26 04 75 - SURGE PROTECTION DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Applicable provisions of the General Conditions, Supplementary General Conditions and Special Conditions shall govern work performed
More informationDTK-WH8PLUS. Premium Whole House Surge Protection General Product Specifications
DTK-WH8PLUS Premium Whole House Surge Protection DITEK s WH8PLUS Whole House surge protection kit is perfect for residential builders and contractors who desire to provide an additional, valuable service
More informationLiebert TVSS: The First Line of Defense - Product Overview. Jim Tiesi
Liebert TVSS: The First Line of Defense - Product Overview Jim Tiesi INTERCEPTOR SURGE SUPPRESSION Overall Design True modular design Low impedance copper conduction plates Best in class performance Real-time
More informationTHE SURGE PROTECTION SOLUTION
THE SOLUTION Unique product features and benefits never before offered in the surge protection industry POWER QUALITY INTERNATIONAL, LLC 2404 Merchant Ave., Odessa, Florida, USA 33556 (888) 539-7712 PowerQuality.net
More informationArchitecture - Engineering - Planning
Architecture - Engineering - Planning www.mkcinc.com Mansfield, Ohio New Philadelphia, Ohio Powell, Ohio 419-525-1102 - phone 330-364-8871 - phone 740-657-3202 - phone 419-525-1428 - fax 330-343-3075 -
More informationB. System Design and Performance Requirements
Change History Date Description of Change Pages / Sections Modified 6/15/16 Updated division section from 16289 to 26 35 00, removed references to other section numbers 10/14/14 Amend text in section B
More informationSECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS
SECTION 264313 - TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and
More informationApplication Techniques CENTERLINE 2100 Motor Control Centers
POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product
More informationFile E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7)
File E3456 Project 08NK10151 November 24,09 REPORT ON TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7) *********************************************************** Complementary Product Category ELECTROMAGNETIC
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase
More informationTDX Series. Transient Discriminating TM TVSS
TDX Series Transient Discriminating TM TVSS TDX Series TDX150 is ideal for service entrance protection. Best Value Engineered Protection With emphasis on efficiency and value, ERICO developed the TDX Series.
More informationInstallation and Operation Manual
Installation and Operation Manual APC 2X Series Hardwire Products PMP2X-A PMF2X-A PMG2X-A PMH2X-A APC hardwired products are designed to provide specification-grade performance at the service entrance,
More informationGENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.
[Refer to Engineering Notes at End of Spec] Section [16XXX] [264XXX] - SURGE PROTECTIVE DEVICES (SPDs) PART 1 - GENERAL 1.1 SCOPE A. This section includes Surge Protective Devices (SPDs) for low-voltage
More informationBUSSMANN. North American UL Type 1, 2 and 4, and data signal surge protective devices SERIES. Application note 3193
Application note 3193 Supersedes January 2015 BUSSMANN North American UL Type 1, 2 and 4, and data signal surge protective devices SERIES Application Note 3193 Application note for North American Contents
More informationSECTION SWITCHBOARDS
SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS
More informationMaximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches
Series 300 Power Transfer Switches Maximum Reliability & Excellent Value With a Series 300 Transfer Switch, you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually
More informationIPaCS Equipment Overview Modular Panelboard System Integrated Power Center Integrated Power Center
Table of Contents Section 0 Integrated Power and Control Solutions (IPaCS) Equipment IPaCS Equipment Overview 0- Modular Panelboard System 0-3 Integrated Power Center 0-3 Standby Power Connection Solutions
More informationINSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)
Surge-Trap STZ-R series Surge Protective Device (SPD) Danger Hazard of Electrical Shock, Explosion or Arc Flash Only qualified licensed electricians should install or service SPDs Verify that all power
More information1. This section describes the materials and installation requirements for surge protective devices (SPD) for the protection of all AC electrical
Spec Interpretation The purpose of this PowerPoint is to highlight the areas of the written spec and electrical drawings which contain the information required to determine a TPS part number for quoting
More informationGENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.
[Refer to Engineering Notes at End of Spec] Section [16XXX] [264XXX] - SURGE PROTECTIVE DEVICES (SPDs) PART 1 - GENERAL 1.1 SCOPE A. This section includes Surge Protective Devices (SPDs) for low-voltage
More informationInstallation and Operation Manual
Installation and Operation Manual APC Panel Mount Modular SPDs PMP3S-A PMP3DS-A PMP4S-A PMP4DS-A PMF3S-A PMF3DS-A PMF4S-A PMF4DS-A PMG3S-A PMG3DS-A PMG4S-A PMG4DS-A PML3S-A PML3DS-A PML4S-A PML4DS-A The
More informationDANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.
Installation/Operation Manual TABLE OF CONTENTS Page UNPACKING AND INSTALLATION Unpacking and Preliminary Inspection...2, 3 Model Number...9 LOCATION CONSIDERATIONS Environment, Equipment Performance,
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42
More informationProtecting the electronic world from surges
Protecting the electronic world from surges 2016 SPD PRODUCT CATALOG Surge Protective Devices www.aptsurge.com 1.800.237.4567 info@aptsurge.com Table of Contents SPD Sizing Chart...5 Type 1 and Type 2
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225 A, 8 to 42
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase
More informationSection 9 TVSS. Contents
Section Contents TPS General Information -2 Internal Equipment Mounted Unit Selection TPS 1, TPS 5, TPS 6-3 External or Remote Mounted Unit Selection TPS and TPS 10 TPS 11 and TPS 12-4 -5 - Transient Voltage
More informationSURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B
SURGE PROTECTION PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) USER MANUAL Surge Protection Device B 01 156 9000 This Surge Protection Device is intended for professional use only Read this
More informationPDI Modular Compact Remote Power Panel
Guide Specifications (Revision 000, 6/17/2016) 1 GENERAL 1.1 Summary These specifications describe requirements for a remote power panel (RPP) distributing power to sensitive loads. These specifications
More informationEaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289
PART 1 - GENERAL DIVISION 16 SECTION 16289 TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) 1 RELATED DOCUMENTS General: Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationSECTION DISTRIBUTION SWITCHBOARDS
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 26 24 11 This section specifies the furnishing, installation, and connection of the distribution switchboards. 1.2 RELATED WORK: A. Section 13 05 41, SEISMIC RESTRAINT
More informationEaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289
PART 1 - GENERAL DIVISION 16 SECTION 16289 TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) 1.1 RELATED DOCUMENTS General: Drawings and general provisions of the Contract, including General and Supplementary
More informationSINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA
SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA SUPRESOR PRINCIPAL DE 300 KA. ST-SMLA 3N4 TRANSIENT VOLTAGE SURGE SUPPRESSORS. PROTECTION AGAINST
More informationThe protection you rely on
Surge protective devices 13 Contents The protection you rely on Section page Description Type 1 SPDs Selecting Type 1 SPDs 2-3 SurgePOD PRO Type 1, NEMA 4 4-5 BSPA, Type 1 and 2, NEMA 4 6-9 BSPD high capacity
More informationPrevent Thousands of Dollars in Damage with Square D Whole Home Surge Protection
Block Your Shock Contact your certified electrical contractor to install Square D Whole Home Surge Protection today. Prevent Thousands of Dollars in Damage with Square D Whole Home Surge Protection FOR
More informationFrom houses to high-rises
ndustrial Solutions rom houses to high-rises Residential products and solutions More choices. exclusive options. continues to provide products and solutions for your residential installations that are
More informationKohler Generac (even new low voltage board).
Small footprint, typically a quarter of the size of 100 & 200 Amp contactors Magnetic toggle is virtually silent in operation, no heat, humming or buzzing and never electrically held in either position
More informationOVRH catalog Surge protective devices
OVRH catalog Surge protective devices 2 Product catalog OVRH series surge protective devices Table of contents SPDs IEC and UL SPD Test Standards Terminology...4 Fill in contents when all page content
More informationSurge Protection V1-T2-2 V1-T2-2 V1-T2-3 V1-T2-4. Learn Online
Surge Protection Surge Protection Devices.1 Product Description...................................... Application Description.................................... Standards and Certifications................................
More informationI-Line Panelboards. Innovative design, smart bus technology, and simple installation
I-Line Panelboards Innovative design, smart bus technology, and simple installation TM Smart: designed for efficient installation Simple: Efficient Installation Process I-Line Breakers Main Lugs: Fixed-mounted
More informationPowering innovation. Powering efficiency. Powering home
Powering efficiency Powering home DISCONNECTS The best prices & selection in Siemens general, industrial & heavy duty safety switches for every application. Powering innovation Illustrating the diverse
More informationSurge Protection V1-T2-2 V1-T2-2 V1-T2-3 V1-T2-4. Learn Online
Surge Protection Surge Protection Devices.1 Product Description....................................... Application Description.................................... Standards and Certifications................................
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationInstruction Manual IM E Table of Contents
Instruction Manual IM01005031E Effective For Mounting External To Table of Contents 1.0 Introduction 2.0 Installation 3.0 Operating Features 4.0 Troubleshooting 5.0 Specifications 6.0 Ordering Guidelines
More informationEquipment level protection for AC/DC network cable, data and low voltage applications. Available in din-rail and direct inline installation.
Panel mount devices can be installed directly on the main electrical panel or equipment disconnect. Devices range from 100,000 to 400,000 surge Amp capacity and are available in 4, 7 and 10 mode configurations.
More informationFile E Project 08NK October 2, 2009 REPORT SURGE PROTECTIVE DEVICES (VZCA) GE Zenith Controls Bonham, TX
File E3456 Project 08NK10151 October 2, 9 REPORT ON SURGE PROTECTIVE DEVICES (VZCA) GE Zenith Controls Bonham, TX Copyright 9 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the
More informationProtect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Light Gray Housing
Protect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Housing MODEL NUMBER: STRIKER Highlights 7 NEMA 5-15R outlets one designed for a bulky transformer 1080-joule surge protection
More informationR-LB R-LX Series Installation, Operation & Maintenance Manual
Installation, Operation & Maintenance Manual WARNINGS Safety First Hazardous Voltage & Shock Hazard Only qualified licensed electricians should install or service SPDs Hazardous voltages exist within SPDs
More informationSurge Protection for Surveillance Systems
Surge Protection for Surveillance Systems 1-in-1 Protection for Network Cameras 2-in-1 Protection for Power and Audio/Video Signals 3-in-1 Protection for Power, Audio/Video and PTZ Control Signals Application:
More informationProtect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing
Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Housing MODEL NUMBER: TLP1008TEL Highlights 10 NEMA 5-15R outlets, including 4 for bulky transformers
More informationThe General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.
SECTION 16420 - ELECTRICAL EQUIPMENT PART 1 - GENERAL 1.01 RELATED DOCUMENTS The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified
More informationTST SERIES. Din Rail Surge Protective Device for SCADA Systems. Meter-Treater, Inc. Dimensions. Product Specifications. Notes
Utility Equipment Din Rail Surge Protective Device for SCADA Systems The TST Series of SPDs (surge protection devices) are designed to protect sensitive electronic equipment from the harmful effects of
More informationSquare D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions
Square D Meter Centers A Comprehensive Selection of Time-Saving, Reliable Solutions VERSATILITY. DESIGN SUPERIORITY. SELECTION. Installation simplicity. The largest selection of meter centers in the industry.
More informationDigest Changes and Updates
Digest s and Updates - 2011 Digest 175 s Revised through October 2011 Click here for links to Digest 175 product line sections revised or updated since printing in March, 2009. Included are changes related
More informationHubbell Surge Protective DeviceS
Hubbell Surge Protective DeviceS Hubbell Modular Panel Products Surge Protective Devices (SPD) The Hubbell Modular Panel Product Surge Protective Devices (SPD) are designed to provide protection at the
More informationGE Digital Energy. Power Quality
GE Digital Energy Power Quality INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Enhanced Thermal Protection (ETP) Series Wall Mounted Medium and High Exposure Surge Protective Devices (SPDs)
More informationFile E Project 05NK Issued: Revised: REPORT CLASSIFIED FOR USE WITH SPECIFIED EQUIPMENT (XUPD)
File E248748 Project 05NK27956 Issued: 2007-11-01 Revised: 2009-12-04 REPORT on SURGE PROTECTIVE DEVICES/PANELBOARD EXTENSION MODULES, CLASSIFIED FOR USE WITH SPECIFIED EQUIPMENT (XUPD) GE ZENITH CONTROLS
More informationProtect your facility from the destructive effects of power surges with a fully
Protect your facility from the destructive effects of power surges with a fully configurable panel protection solution from The Wiremold Company. The all new ZoneMaster Series is fully configurable with
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationProtect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing
Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Housing MODEL NUMBER: TLP1008TEL Highlights 10 NEMA 5-15R outlets, including 4 for bulky transformers
More informationWhite Paper Avoiding SPD Procurement Errors
White Paper Avoiding SPD Procurement Errors Avoiding SPD Procurement Errors Application Information and Manufacturer Support are Keys to Receiving Correct SPDs BACKGROUND INFORMATION Surge protection devices
More informationSECTION TRANSIENT VOLTAGE SURGE SUPPRESSION
SECTION 16709 TRANSIENT VOLTAGE SURGE SUPPRESSION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Transient Voltage Surge Suppression (TVSS) devices, also known as Surge Protective Devices (SPDs), for
More informationTPS3 09. Surge Protective Device. User Manual - USA
TPS3 09 Surge Protective Device User Manual - USA V WARNING - Hazardous Voltage & Shock Hazard Failure to Follow These Instructions Could Result in Death or Serious Injury Only qualified licensed electricians
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationSurge Protection Devices OVR series
PRODUCT CATALOGUE CANADA Surge Protection Devices OVR series UL / CSA range of SPDs Type 1 and Type 2 for main electrical distribution equipment and control panel applications Hardwired and DIN rail versions
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationApplication Description. Telephone and Cable Accessories. Type CHSP Surge Protection
February 2007 Description -3 Stage 1 Service Entrance Surge Protection Factory Installed Telephone and Cable Accessories Surge Panel Industry Breakthrough Eaton is the first to introduce a factory installed
More informationZoneMaster Series Surge Protection Devices
ZoneMaster Series Surge Protection Devices New Improved ZoneMaster Series Configurable Hard-Wired Surge Protection Devices Wiremold ZoneMaster Series Surge Protection Devices are fully configurable panel
More informationApril 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control
Section A6 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. 5-8-15 3 Removed model 1503. Added models 1509 / 1515 (Pg 15) to the TOC. 8-10-15
More informationSurge Protective Devices. Installation & Operation Manual. Model 420
Surge Protective Devices Installation & Operation Manual Model 420 CALIFORNIA CUSTOMERS - PROP 65 WARNING WARNING: This product can expose you to chemicals including DINP, which is known to the State of
More information