MOTOR & CIRCUIT PROTECTION

Size: px
Start display at page:

Download "MOTOR & CIRCUIT PROTECTION"

Transcription

1 2 MOTOR & CIRCUIT PROTECTION Motor Protection Circuit Breakers p2-1 Motor Protection Relays p2-13 Thermistor Protection Relay p2-18 Fuse Holders p2-20 Miniature Circuit Breakers p2-23 Residual Current Circuit Breakers p2-31 Surge Protection Devices p2-35 Perth (08) Sydney (02) Melbourne (03) Adelaide (08) Brisbane (07) PAGE 2-0

2 Motor Protection Circuit Breakers Motor protection circuit breakers SM1 up to 40A. Magnetic and thermal protection SM1P... SM1R... Motor protection circuit breakers SM1RM up to 40A. Magnetic protection SM1RM... Order code Thermal Short circuit Qty Wt trip breaking per adjustment capacity pack range at 400V Icu Ics Button control. [A] [ka] [ka] n [kg] SM1P SM1P SM1P SM1P SM1P SM1P SM1P SM1P SM1P SM1P SM1P SM1P SM1P SM1P SM1P SM1P Rotating type. SM1R SM1R SM1R SM1R SM1R SM1R SM1R SM1R SM1R SM1R SM1R SM1R SM1R SM1R SM1R SM1R Order code Rated and Short circuit Qty Wt magnetic breaking per trip current capacity pack at 400V Rat. Trip. Icu Ics [A] [A] [ka] [ka] n [kg] Rotating type. SM1RM SM1RM SM1RM SM1RM SM1RM SM1RM SM1RM SM1RM SM1RM SM1RM SM1RM SM1RM SM1RM SM1RM SM1RM SM1RM See page 2-9 for dimensions. General characteristics SM1P... and SM1R... are modern circuit breakers with thermal and magnetic trip releases and high breaking capacity. Motor control and protection of up to 22kW (400V) are possible by choosing the suitable adjustment range, from 0.1 to 40A. The dimensions of SM1P breakers are compliant with the DIN43880 standard, allowing them to be mounted in all modular enclosures on the market. A magnetic trip indicator integrated on the SM1R breakers avoids dangerous closing operations during shortcircuit conditions, previously disconnected by the breaker. SM1R breakers are Type E-certified according to UL508. SM1P and SM1R motor protection circuit breakers are suitable for isolation in accordance with IEC/EN standards and can be padlocked in OFF position without using accessories. Their high breaking capacity permits the elimination of protection fuses on the majority of installations. Operational characteristics IEC rated insulation voltage Ui: 690V IEC rated impulse withstand voltage: 6kV Rated frequency: 50/60Hz Rated maximum current: 40A Adjustment ranges: 16 IEC breaking capacity: see Heat dissipation per phase: W Magnetic tripping: 13In max. Tripping class: 10A Phase failure sensitive Mechanical endurance: 100,000 cycles Electrical endurance: 100,000 cycles Mounting on 35mm DIN rail (IEC/EN 60715) Mounting position: any IEC utilisation category: A Padlocking in OFF: Ø4mm/0.16 Protection rating: IP20. Certifications and compliance Certifications obtained: culus, EAC, CCC. SM1R breakers are Type E-certified (Self-Protected Combination Motor Controllers) according to UL508. Compliant with standards: IEC/EN , IEC/EN , IEC/EN , UL508, CSA C22.2 n 14. Plastic materials compliant with standards: IEC/EN and EN General characteristics SM1RM are motor protection circuit breakers with magnetic tripping only and high breaking capacity. They are typically used to protect starters where there is a thermal relay or other overload protection. Starter control and protection of up to 22kW (400V) are possible by choosing the suitable adjustment range, from 0.1 to 40A. Operational characteristics IEC rated insulation voltage Ui: 690V IEC rated impulse withstand voltage: 6kV Rated frequency: 50/60Hz Rated maximum current: 40A IEC breaking capacity: see Heat dissipation per phase: W Magnetic tripping: 13In max. Mechanical endurance: 100,000 cycles Electrical endurance: 100,000 cycles Mounting on 35mm DIN rail (IEC/EN 60715) Mounting position: any IEC utilisation category: A Padlocking in OFF: Ø4mm Protection rating: IP20. Certifications and compliance Certifications obtained: culus, EAC, CCC. Compliant with standards: IEC/EN , IEC/EN , IEC/EN , UL508, CSA C22.2 n 14. Plastic materials compliant with standards: IEC/EN and EN PAGE 2-1

3 Motor Protection Circuit Breakers Motor protection circuit breakers SM2... and SM3... up to 100A. Magnetic and thermal protection SM2R... SM3R... Order code Thermal Short circuit Qty Wt trip breaking per adjustment capacity pack range at 400V Icu Ics [A] [ka] [ka] n [kg] Rotating type. SM2R SM2R Rotating type. SM3R SM3R SM3R General characteristics SM2R... and SM3R... are modern circuit breakers with thermal and magnetic trip releases and high breaking capacity. Motor control and protection of up to 45kW (400V) are possible by choosing the suitable adjustment range, up to 100A. SM2R and SM3R breakers are Type E-certified according to UL508. The SM2R and SM3R types are suitable for isolation according to IEC/EN standards and can be padlocked in OFF position without using accessories. SM3 has a trip function which indicates thermal and magnetic tripping. Their high breaking capacity permits the elimination of protection fuses on the majority of installations. Operational characteristics IEC rated insulation voltage Ui: 1000V IEC rated impulse withstand voltage: 8kV Rated frequency: 50/60Hz Rated maximum current: 63A (for SM2...); 100A (for SM3...) Adjustment ranges: 2 (for SM2...); 3 (for SM3...) IEC breaking capacity: see Max. heat dissipation per phase: 7W Magnetic tripping: 13In max. Tripping class: 10A Phase failure sensitive Mechanical endurance: 50,000 cycles Electrical endurance: 25,000 cycles Mounting on 35mm DIN rail (IEC/EN 60715) Mounting position: any IEC utilisation category: A Padlocking in OFF: Ø4mm/0.16 Protection rating: IP20 on front. Certifications and compliance Certifications obtained: culus, EAC, CCC. SM2 and SM3 circuit breakers (only with accessory SM3X90 00R) are Type E-certified (Self-Protected Combination Motor Controllers) according to UL508. Compliant with standards: IEC/EN , IEC/EN , IEC/EN , UL508, CSA C22.2 n 14. SM1PF... circuit breakers Fuse monitoring function SM1PF... Order code Fixed Short circuit Qty Wt thermal breaking per release capacity pack current at 400V Icu Ics [A] [ka] [ka] n [kg] Button control. SM1PF L1 L2 L3 T1 T2 T3 General characteristics SM1PF are breakers with magneto-thermal tripping intended specifically for monitoring the status of fuses. By connecting every phase of the breaker to a fuse, when it blows, the motor protection breaks. Through the auxiliary contacts fitted on the engine protection, the blown fuses are signalled electrically. Operational characteristics IEC rated insulation voltage Ui: 690V IEC rated impulse withstand voltage: 6kV Rated frequency: 50/60Hz Rated current: 0.2A Magnetic tripping: 1.2A. Mechanical endurance: 100,000 cycles Electrical endurance: 100,000 cycles Mounting on 35mm DIN rail (IEC/EN 60715) Mounting position: any IEC utilisation category: A Padlocking in OFF: Ø4mm/0.16 Protection rating: IP20. Certifications and compliance Certifications obtained: culus, EAC, CCC. Compliant with standards: IEC/EN , IEC/EN , IEC/EN , UL508, CSA C22.2 n 14. Plastic materials compliant with standards: IEC/EN and EN See page 2-9 for dimensions. PAGE 2-2

4 Motor Protection Circuit Breakers Add-on blocks and accessories for SM1 SM1X11... SM1X12... SM1X14... SM1X15... SM1X18 200R SM1X18B 200R SM1X18 S SM1X13... SM1X16... SM1X89 02 BFX89 01 Order Characteristics Qty Wt code per pack Add-on auxiliary contacts. n [kg] SM1X11 20 Front mount 2NO SM1X11 11 Front mount 1NO+1NC SM1X12 20 Side mount 2NO SM1X12 11 Side mount 1NO+1NC SM1X12 02 Side mount 2NC SM1X13 11 Side mount. Contacts for thermal and magnetic tripping indication 1NO+1NC SM1X13 11M Side mount. Contacts for magnetic tripping indication 1NO+1NC Undervoltage trip releases. SM1X VAC 50/60Hz SM1X VAC 50/60Hz SM1X VAC 50/60Hz SM1X15 110R With early-make contacts VAC 50/60Hz SM1X15 230R With early-make contacts VAC 50/60Hz SM1X15 400R With early-make contacts VAC 50/60Hz Shunt trip releases. SM1X VAC 50/60Hz SM1X VAC 50/60Hz SM1X VAC 50/60Hz SM1X VAC 50/60Hz Adjuster sealing kit. SM1X18 12 With wire and lead included IP65 padlockable door coupling handle for SM1R... SM1X18 200R Red/yellow complete with rod length 200mm/7.87 SM1X18B 200R Black complete with rod length 200mm/7.87 SM1X18 S Support for rod >145mm/5.71 Phase separation barriers for SM1R SM1X9000R For Type E as per UL Three-phase connection busbars 45mm/1.77 spacing. 11 SMX90 32 For 2 breakers SMX90 33 For 3 breakers SMX90 34 For 4 breakers SMX90 35 For 5 breakers Three-phase connection busbars 54mm/2.13 spacing. 11 SMX90 42 For 2 breakers SMX90 43 For 3 breakers SMX90 44 For 4 breakers SMX90 45 For 5 breakers Terminal block for busbar supply. 11 SMX90 30 For all busbar types SM1X90 50 For all busbar types Type E as per UL508 Safety cover. 11 SMX90 31 For unused terminals Accessories for screw-fixing motor protection. SM1X89 02 Metal brackets for fixing SM1 motor protection with screws BFX89 01 Universal plastic base for screw-fixing SM1 motor protection Only suitable for SM1R... motor protection circuit breakers General and operational characteristics ADD-ON AUXILIARY CONTACTS Connectable to the left side of the breaker or on the front Maximum combinations: 3 SM1X blocks with 6 auxiliary contacts in total of which 1 front block and 2 side blocks IEC conventional free air thermal current Ith: 10A (5A for SM1X11...) IEC rated insulation voltage Ui: 690V (300V for SM1X11...) Rated impulse withstand voltage Uimp 6kV (4kV for SM1X11...) IEC/EN designation: A600 - Q600 (B300 - R300 for SM1X11...) Maximum tightening torque: 1Nm / 9lbin Conductor cross section minimum-maximum (1 or 2 wires): mm 2 or AWG. Screw tightening tool: Phillips 2 Maximum tightening torque: 1Nm / 9lbin Width of side-mount auxiliary contacts equal to 0.5 DIN modules. UNDERVOLTAGE TRIP RELEASES Snap on to the right side of the breaker Consumption inrush/holding: 12/3.5VA Release voltage: Us Operating voltage: Us Maximum tightening torque: 1Nm / 9lbin Conductor cross section minimum-maximum (1 or 2 wires): mm 2 or AWG. Screw tightening tool: Phillips 2 Maximum tightening torque: 1Nm / 9lbin Width of side-mount auxiliary contacts equal to 1 DIN module. SHUNT TRIP RELEASES Snap on to the right side of the breaker Inrush consumption: 20VA Operating voltage: Us Conductor cross section minimum-maximum (1 or 2 wires): mm 2 or AWG. Screw tightening tool: Phillips 2 Maximum tightening torque: 1Nm / 9lbin Width of side-mount auxiliary contacts equal to 1 standard DIN module. TERMINAL BLOCKS FOR BUSBAR SUPPLY Imax 63A Screw tightening tool: Phillips 2 Maximum tightening torque: 2.3Nm / 20lbin Conductor cross section minimum-maximum: mm 2 or AWG. THREE-PHASE CONNECTION BUSBARS Imax 63A SMX mm/1.77 spacing to reduce the width to the minimum SMX mm/2.13 spacing to consent to fit one side mount auxiliary contact block on the breakers. Certifications and compliance Certifications obtained: culus, EAC, CCC. Compliant with standards: IEC/EN , IEC/EN , UL508, CSA C22.2 n 14. PAGE 2-3

5 Motor Protection Circuit Breakers Add-on blocks and accessories for SM1 SM1X30... SM1X31... SM1X32... SM1Z17 01P SM1Z17 05P SM1X17 40P SM1X17 46P SM1Z17 02P SM1Z17 15R SM1X17 45P 11 SMX SMX90 12 Order code Characteristics Qty Wt per pack Rigid SM1 breaker-contactor connections. n [kg] SM1X30 40P For motor protection breaker SM1P... with BG mini-contactors SM1X31 41P For motor protection breaker SM1P... with BF09..25A contactors SM1X32 41P For motor protection breaker SM1P... with BF26..38A contactors SM1X30 40R For motor protection breaker SM1R... with BG mini-contactors SM1X31 41R For motor protection breaker SM1R... with BF09..25A contactors SM1X31 42R For motor protection breaker SM1R... with contactors BF09..25D and BF09 25L SM1X32 41R For motor protection breaker SM1R... with contactors BF26..38A Surface mount enclosures IP65 for SM1P... SM1Z17 01P Width 80mm/ SM1Z17 02P Width 80mm/3.15. With button for emergency stop SM1Z17 11P Width 100mm/ SM1Z17 12P Width 100mm/3.94. With button for emergency stop Flush mount enclosure IP65 for SM1P... SM1Z17 05P Width 87mm/ Surface mount enclosures IP65 for SM1R... SM1Z17 15R With rotary actuator red/yellow. Width 100mm/3.94 SM1Z17 10R With black rotary actuator Width 100mm/3.94 ENCLOSURE ACCESSORIES AND SPARE PARTS. For SM1Z...P enclosures. SM1X17 40P Emergency stop button. IP65 SM1X17 45P Rubber membrane with rim. IP65 SM1X17 46P Lockable block. IP Pilot lights. 23 NEONV V Green NEONV R Red Plastic M25 to ½ NPT entry adapter. 11 LM M25 PG16 For enclosures SM1Z17 01P and SM1Z17 02P Starter assembly adapter plates. 11 SMX90 10 Adapter plate for direct starter comprising breaker SM1... and contactor BG..., BF09A...BF38A 11 SMX90 12 Adapter plate for reversing switch comprising breaker for motor protection SM1 contactors BG..., BF09A...BF38A 11 SMX90 14 Adapter plate for starter star-delta comprising motor protection breaker SM1... and contactors BF09A...BF38A 11 SMX mm rail for passage of wires underneath to contactor; for SMX SMX90 19 DIN rail extension mm/1.38 Complete with required voltage. Available voltages: AC 50/60Hz 24/110/ VAC (indicate 220)/ VAC (indicate 380). General and operational characteristics RIGID SM1 BREAKER-CONTACTOR CONNECTIONS The SM1X3 connections electrically and mechanically fasten the motor protection breaker together with the contactor. This forms a highly compact single-unit starter for quick installation on a single 35mm DIN rail. The SM1X3 connections can also be mounted in combination with reversing switches and star-delta starters made with the rigid connections indicated in section 1. SURFACE MOUNT ENCLOSURES Top or bottom entry: SM1Z17 01P and SM1Z17 02P 4 M25-threaded knockouts SM1Z17 11P e SM1Z17 11P 4 threaded knockout with Ø20.5mm/0.81 or Ø26.5mm/1.04 SM1Z17 10R e SM1Z17 15R 4 threaded knockout with Ø20.5mm/0.81 or Ø26.5mm/1.04 Possibility of rear entry too Protection rating: IP65 (UL Type 4X) Holds a breaker, one front-mount auxiliary contact block and either one shunt or undervoltage release; only for SM1Z17 10R and SM1Z17 15R, 2 side-mount auxiliary contact blocks can be fitted as well The SM1Z17 10R and SM1Z17 15R rotary actuators can be padlocked with a maximum of 3 padlocks Ø4...8mm/ Earth/ground terminal included Operating temperature: C Storage temperature: C. FLUSH MOUNT ENCLOSURES Holds a breaker, one front-mount auxiliary contact block and either one shunt or undervoltage release Protection rating: IP65 (UL Type 4X) Earth/ground terminal included 70x115mm/2.76x4.53 cutout Operating temperature: C Storage temperature: C. ACCESSORIES FOR ENCLOSURES Emergency stop button: Turn to release Red button Ø35mm/1.38. Lockable block: Prevents closing operation; 3 padlocks maximum Ø4...8mm/ STARTER ASSEMBLY ADAPTER PLATES These accessories permit the assembly of starters, making trim and compact equipment that s easy and quick to install. The starter adapter plates install on DIN rail 35mm/1.38. Certifications and compliance Certifications obtained: culus, EAC, CCC for rigid connections and enclosures. Compliant with standards: IEC/EN , IEC/EN , UL508, CSA C22.2 n 141. See page 2-10 for dimensions. 11 SMX90 14 PAGE 2-4

6 Motor Protection Circuit Breakers Add-on blocks and accessories for SM2... and SM3... SM2X11... SM2X12... SM2X13 11 SM2X14... SM2X16... SM2X18... Order Characteristics Qty Wt code per pack n [kg] Add-on auxiliary contacts. SM2X11 20 Front mount 2NO SM2X11 11 Front mount 1NO+1NC SM2X11 02 Front mount 2NC SM2X12 20 Side mount 2NO SM2X12 11 Side mount 1NO+1NC SM2X12 02 Side mount 2NC SM2X13 11 Side mount Indicator contacts for thermal and magnetic tripping 1NO+1NC Undervoltage trip releases. SM2X VAC 50/60Hz SM2X VAC 50/60Hz SM2X VAC 50/60Hz Shunt trip releases. SM2X VAC 50/60Hz SM2X VAC 50/60Hz SM2X VAC 50/60Hz SM2X VAC 50/60Hz SM2X VAC 50/60Hz Padlockable IP65 door coupling handle. SM2X18 200R Red/yellow complete with rod length 200mm/7.87 SM2X18 B200R Black complete with rod with rod length 200mm/7.87 Phase separation barriers for SM2R SM3X90 00R For Type E as per UL General and operational characteristics ADD-ON AUXILIARY CONTACTS Insert on the top front or snap on the left side of the breaker Maximum combinations: 3 SM1X blocks with 6 auxiliary contacts in total of which 1 front block and 2 side blocks IEC conventional free air thermal current Ith: 10A (5A for SM2X11...) IEC rated insulation voltage Ui: 690V (250V for SM2X11...) IEC/EN designation: A600 Q300 (B300 - R300 for SM1X11...) Maximum tightening torque: 1.2Nm / 9lbin Conductor cross section minimum-maximum (1 or 2 wires): m or AWG Screw tightening tool: Pz 2 Maximum tightening torque: 1.2Nm / 10bin Width of side-mount auxiliary contacts equal to 0.5 DIN modules. UNDERVOLTAGE TIP RLEASES Snap on to the right side of the breaker for motor protection Consumption inrush/holding: 8.5/3VA Release voltage: Us Operating voltage: Us Maximum tightening torque: 1Nm / 9lbin Conductor cross section minimum-maximum (1 or 2 wires): mm 2 or AWG Sscrew tightening tool: Pz 2 Maximum tightening torque: 1.2Nm / 10lbin Width of side-mount auxiliary contacts equal to 1 DIN module. SHUNT TRIP RELEASES Snap on to the right side of the breaker for motor protection Inrush consumption: 20VA Operating voltage: Us Conductor cross section minimum-maximum (1 or 2 wires): mm 2 or AWG Screw tightening tool: Pz 2 Maximum tightening torque: 1.2Nm / 10lbin Width of side-mount auxiliary contacts equal to 1 standard DIN module. Certifications and compliance Certifications obtained: culus, EAC. Compliant with standards: IEC/EN , IEC/EN , UL508, CSA C22.2 n 14. PAGE 2-5

7 MOTOR & CIRCUIT PROTECTION Motor Protection Circuit Breakers Add-on blocks and accessories for SM1 Combinations SM1X14... SM1X15... SM1X12... SM1R... SM1X12... SM1X11... SM1X12... SM1X16... SM1X13 11 SM1X12... SM1X13 11M SM1P... SM1X11... Only suitable for SM1R... motor protection circuit breakers SM1X13 11 SM1X13 11M SM1X13 11M Three-phase connection busbars. SMX90 30 SMX90 35 SMX90 31 SMX90 34 Three-phase connection busbar, 45mm/1.77 spacing (breakers without add-on blocks). SMX90 32 SMX90 33 SMX90 45 SMX90 30 SMX90 31 SMX90 44 SMX90 43 SMX90 42 Three-phase connection busbar, 54mm/2.13 spacing (breakers with add-on blocks) Perth (08) Sydney (02) Melbourne (03) Adelaide (08) Brisbane (07) PAGE 2-6

8 Motor Protection Circuit Breakers Add-on blocks and accessories for SM1 Combinations Rigid SM1P... breaker - contactor connections. SM1P... SM1P... SM1P... SM1X30 40P SM1X31 41P SM1X32 41P BG... BF09A...BF25A BF26A...BF38A Rigid SM1R... breaker - contactor connections. SM1R... SM1R... SM1R... SM1X30 40R SM1X31 41R SM1X31 42R SM1X32 41R BG... BF09...BF25 BF26A...BF38A For BF09A...BF25A contactors. For BF09D BF25D and BF09L BF25L contactors. Padlockable door coupling handle. SM1R... SM1X18 S SM1X18 200R SM1X18B 200R PAGE 2-7

9 L MOTOR & CIRCUIT PROTECTION Motor Protection Circuit Breakers Add-on blocks and accessories for SM1, SM2A... and SM3A... Combinations Surface mount enclosures for SM1P... Width 80mm. Surface mount enclosures for SM1P... Width 100mm. SM1Z17 02P SM1Z SM1X14... SM1X16... SM1Z17 01P SM1P... SM1X14... SM1X11... Surface mount enclosures for SM1R... Width 100mm. SM1Z17 10R SM1Z17 15R SM1X14... SM1X15... SM1X16... Combinations of SM2... and SM3... motor protection circuit breakers SM1X1... SM1X14... SM1R... SM1X11... SM1X1... Padlockable door coupling handle. SM2X14... SM2X16... Lovato SM2... SM3... SM2X11... L Lovato SM2X13 11 SM2X12... SM2X12... SM2X12... PAGE 2-8

10 Motor Protection Circuit Breakers Dimensions [mm (in)] SM1P... with side-mount auxiliary contacts 9 (0.35 ) 80.8 (3.18 ) 18 (0.71 ) SM1R... with side-mount auxiliary contacts 9 (0.35 ) 80.8 (3.18 ) 18 (0.71 ) 90 (3.54 ) 96.6 (3.92 ) 90 (3.54 ) 37.5 (1.48 ) 44.4 (1.75) 44.8 (1.76 ) SM1X12... SM1X13... SM1X14... SM1X15... SM1X (0.22 ) 43.6 (1.72 ) 62.2 (2.45 ) 69.6 (2.74 ) 49 (1.93 ) 74.5 (2.93) 85.6 (3.37 ) SM1P... with BG mini-contactors and connection SM1X30 40P 44.8 (1.76 ) 75.1 (2.96 ) SM1P... with BF09 A...BF25 A... contactors and connection SM1X31 41P SM1P... with BF26 A...BF38 A... contactors and connection SM1X32 41P (6.36 ) SM1X30 40P (7.44 ) SM1X31 41P (7.80 ) SM1X32 41P 45 (1.77 ) 80.4 (3.16 ) 45 (1.77 ) 89.8 (3.53 ) SM1R... with BG mini-contactors and connection SM1X30 40R 44.8 (1.76 ) 91.1 (3.59 ) SM1R... with BF09 A...BF25 A... contactors and connection SM1X31 41R 44.8 (1.76 ) 91.1 (3.59 ) SM1R... with BF09 D...BF25 D... contactors BF09 L...BF25 L... and connection SM1X31 42R (6.36 ) SM1X30 40R (7.44 ) SM1X31 41R (7.45 ) SM1X31 42R 45 (1.77 ) 98.5 (3.88 ) SM1R... with BF26 A...BF38 A... contactors and connection SM1X32 41R SM1R... padlockable door coupling handle SM1X18 200R or SM1X18B 200R 91.1 (3.59 ) SM1X18 200R SM1X18B 200R 94.6 (3.72 ) 90 (3.54 ) 96.6 (3.92 ) 90 (3.54 ) 37.5 (1.48 ) 44 (1.73 ) 44.8 (1.76 ) SM1X12... SM1X13... SM1X14... SM1X15... SM1X (0.22 ) (7.80 ) SM1X32 41R 44.8 (1.76 ) 5.5 (0.22 ) 74.5 (2.93 ) min. 48 (1.89 ) / max. 212 (8.35 ) 36 (1.42 ) 45 (1.77 ) PAGE 2-9

11 Motor Protection Circuit Breakers Dimensions [mm (in)] These elements mounted with SM1... breakers with no auxiliary contacts 29 (1.14 ) 13.5 (0.53 ) SMX90 30 SMX (0.53 ) 29 (1.14 ) These elements mounted with SM1... breakers with auxiliary contacts SMX12... or SMX (1.14 ) 13.5 (0.53 ) SMX90 30 SMX (0.53 ) 29 (1.14 ) SMX90 31 SMX90 31 Connection busbars 54mm/2.13 spacing SMX SMX SMX SMX90 45 Connection busbars 45mm/1.77 spacing SMX SMX SMX SMX90 35 Terminal block for busbar supply SMX90 30 Safety cover SMX (2.13 ) 45 (1.77 ) Enclosures SM1Z17 01P and SM1Z17 02P 80 (3.15 ) (6.37 ) Enclosures SM1Z17 05P 87 (3.42 ) 18 (0.71 ) 70.5 (2.77 ) 86 (3.38 ) 135 (5.31 ) 126 (4.96 ) (5.22 ) (4.54 ) M2542 (1.65 ) Cutout 22 (0.87 ) 101 (3.98 ) Enclosures SM1Z17 11P and SM1Z17 12P 100 (3.94 ) (6.92 ) Enclosures SM1Z17 15R and SM1Z17 10R 100 (3.94 ) 115 (4.53 ) 54 (2.12 ) (5.42 ) 23.3 (0.92 ) 154 (6.06 ) 159 (6.26 ) 54 (2.12 ) 115 (4.53 ) 23.3 (0.92 ) 154 (6.06 ) PAGE 2-10

12 Motor Protection Circuit Breakers Dimensions [mm (in)] SM2... with side-mount auxiliary contacts SM3... with side-mount auxiliary contacts SM2X11... SM2X (0.39 ) 17 (0.67 ) 20 (0.79 ) SM2X14... SM2X (4.81 ) (4.04 ) 54.5 (2.14 ) SM2X12... SM2X13 11 SM2X11... SM2X (0.49 ) SM2X (0.88 ) SM2X (5.84 ) 138 (5.43 ) (5.07 ) 77 (3.03 ) SM2X11... SM2X12... SM2X (4.92 ) 89 (3.50 ) 45 (1.77 ) 75.5 (2.97 ) 130 (5.12 ) 140 (5.51 ) 165 (6.50 ) 155 (6.10 ) 89 (3.50 ) 45 (1.77 ) 116 (4.57 ) 150 (5.90 ) 9 30 (0.35 ) (1.18 ) 55 (2.16 ) SM2X (0.71 ) (0.29 ) SM2... and SM3... padlockable door coupling handle SM1X18 200R or SM1X18B 200R (4.42 ) (4.97 ) (5.13 ) (5.69 ) 9 30 (0.35 ) (1.18 ) 70 (2.75 ) SMX (0.71 ) 8 (0.31 ) 138 (5.43 ) (6.01 ) 169 (6.65 ) SM1X18 200R SM1X18B 200R 65 (2.56 ) min. 48 (1.89 ) / max. 212 (8.35 ) 36 (1.42 ) 65 (2.56 ) WIRING DIAGRAMS Motor protection circuit breakers SM1P... SM1R... - SM2R... - SM3R... SM1RM... Circuit breakers SM1PF... For all motor protection circuit breakers Three-phase LINE L1 L2 L3 Three-phase LINE L1 L2 L3 Three-phase LINE L1 L2 L3 Three-phase LINE L1 L2 L3 Single-phase and DC LINE L1 L2 T1 T2 LOAD T3 T1 T2 LOAD T3 T1 T2 LOAD T3 T1 T2 LOAD T3 T1 T2 LOAD Add-on blocks For SM1 types Front mount auxiliary contacts SM1X11 20 SM1X11 11 Side-mount auxiliary contacts SM1X12 11 SM1X12 20 SM1X12 02 SM1X13 11 SM1X13 11M Side mount undervoltage trip releases SM1X14... SM1X15... Side mount shunt trip release SM1X D1 D1 O7 C1 U< U< D2 D2 O8 C2 For SM2R and SM3R types Front mount auxiliary contacts SM2X11 20 SM2X11 11 SM2X11 02 Side-mount auxiliary contacts SM2X12 11 SM2X12 20 SM2X12 02 SM2X13 11 Side mount undervoltage trip release SM2X14... Side mount shunt trip release SM2X D1 C1 U< D2 C2 PAGE 2-11

13 Motor Protection Circuit Breakers Technical characteristics TYPE SM1P... SM1R... SM2R... SM3R... Rated insulation voltage Ui V 690 Rated impulse withstand voltage kv 6 Rated frequency: 50/60Hz Maximum rated current A Number of adjustment ranges No Total power dissipation W Magnetic tripping A 13 x In 13 x In 13 x In 13 x In Mechanical life cycles 100, ,000 50,000 50,000 Electrical life (Ie max AC3) cycles 100, ,000 25,000 25,000 Maximum terminal tightening torque Nm lbin Tool PH2 PH2 PZ2 Hex 4mm Conductor section minimum and maximum (1 or 2 wires) AWG No /0 Flexible without lug mm AMBIENT CONDITIONS Temperature operating C storage C compensation C Maximum altitude m 3000 Mounting position Any Fixing On 35mm DIN rail On 35mm DIN rail or screw via accessory or screw N.B. PH = Phillips; PZ = Pozidriv. SM1PF00 20 has a single 0.2A thermal adjustment and magnetic tripping at 6 x In (1.2A). When more than one breaker are mounted, side by side, without leaving space between each to consent free air circulation on the breaker sides, and have simultaneous operation, the thermal trip adjuster must be positioned at a value 15% greater than the rated motor current. THERMAL TRIPPING CURVE (AVERAGE TIMES) Balanced operation on 3 phases Opening time [s] h 1h 30min min 5min 2min 100 1min Operation on 2 phases (phase failure) Opening time [s] h 1h 30min min 5min 2min 100 1min 10 COLD 10 COLD HOT HOT x Ie [A] x Ie [A] Trip times have a ±20% dispersion with respect to the average curve indicated in the graph. PAGE 2-12

14 Thermal Overload Relays for BG Series Mini-contactors Phase failure / single phase sensitive Three poles (three phase) 11 RF9 11 RFA9 Order code Adjustment Protection Qty Wt range fuses per am gg pkg [A] [A] [A] n [kg] MANUAL RESETTING. Direct mounting on BG06, BG09, BG12 mini-contactors. 11 RF RF RF RF RF RF RF9 1V RF9 2V RF RF RF RF RF AUTOMATIC RESETTING. Direct mounting on BG06, BG09, BG12 mini-contactors. 11 RFA RFA RFA RFA RFA RFA RFA9 1V RFA9 2V RFA RFA RFA RFA RFA The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. Three-phase motor powers 230V 400V 415V 440V 500V 690V [kw] [kw] [kw] [kw] [kw] [kw] The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. No standard powers ratings exist; select relay according to current consumption. NOTE: To facilitate connection between the auxiliary NC contact of the RF...9 thermal relay and terminal A2 of the contactor, insert the conductor into the appropriate conduit as shown. RF9... RFA9... Certifications and compliance Certifications obtained: Type RF RFA9... c U G L C O C u S S C s A T C Certified products. Compliant with standards: IEC/EN , IEC/EN , UL508, CSA C22.2 n 14. PAGE 2-13

15 Thermal Overload Relays for BF Series Contactors Phase failure / single phase sensitive Three poles (three phase) RF38 Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg pkg [A] [A] [A] [A] n [kg] MANUAL OR AUTOMATIC RESETTING. Direct mounting on BF09...BF38 contactors. Independent mounting with RFX38 04 base. RF RF RF RF RF RF RF RF RF RF RF RF RF RF RF RF UL RK5 fuse class for RF38 types and UL K5 fuse class for RF 95 types. NOTE: Two pole (single phase) versions are available on request. Add the letter S in the order code e.g. RF is three pole; RFS two pole. The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. Three-phase IEC motor powers 230V 400V 415V 440V 500V 690V [kw] [kw] [kw] [kw] [kw] [kw] No standard powers ratings exist; select relay according to current consumption. The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. Certifications and compliance Certifications obtained: Register of c shipping U L L C E C R u S A C O Tipo s A C C S RF38 Certified products. culus UL Listed for USA and Canada (culus - File E93601) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating up to 82A FLA range and Amps RMS for 95A and 110A FLA range; the trip current is 120% FLA. CSA CSA certified for Canada only (File 54332) as Auxiliary Devices for use with magnetic contactors. Compliant with standards: IEC/EN , IEC/EN , UL508, CSA C22.2 n 14. FIXING EASE OF THE THERMAL OVERLOAD RELAY While the thermal overload relay is being linked to the contactor, its auxiliary contact fits on and connects to the coil terminal by rigid terminal. Complete relay fixing is done in a single operation, with no need of other connections. PAGE 2-14

16 Thermal Overload Relays for BF Series Contactors Phase failure / single phase sensitive Three poles (three phase) RF82 11 RF RFA82 11 RFA Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg pkg [A] [A] [A] [A] n [kg] MANUAL RESETTING. Direct mounting on BF40...BF80 contactors (BF80...A... and...e... type). Complete with G261 links. Independent mounting with G270 base. RF RF RF RF RF MANUAL RESETTING. Direct mounting on BF95...BF110 contactors. Complete with G261 links. Independent mounting with G270 base. 11 RF RF RF AUTOMATIC RESETTING. Direct mounting on BF40...BF80 contactors (BF80...A... and...e... type). Complete with G261 links. Independent mounting with G270 base. RFA RFA RFA RFA RFA AUTOMATIC RESETTING. Direct mounting on BF95...BF110 contactors. Complete with G261 links. Independent mounting with G270 base. 11 RFA RFA RFA UL RK5 fuse class for RF38 types and UL K5 fuse class for RF 95 types. NOTE: Two pole (single phase) versions are available on request. Add the letter S in the order code e.g. RF is three pole; RFS two pole. The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. Three-phase IEC motor powers 230V 400V 415V 440V 500V 690V [kw] [kw] [kw] [kw] [kw] [kw] The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. Certifications and compliance Certifications obtained: Register of c shipping U L L C E C R u S A C O Tipo s A C C S RF82 RFNA82 RF95 RFA95 Certified products. culus UL Listed for USA and Canada (culus - File E93601) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating up to 82A FLA range and Amps RMS for 95A and 110A FLA range; the trip current is 120% FLA. CSA CSA certified for Canada only (File 54332) as Auxiliary Devices for use with magnetic contactors. Compliant with standards: IEC/EN , IEC/EN , UL508, CSA C22.2 n 14. PAGE 2-15

17 Thermal Overload Relays for B Series Contactors Phase failure / single phase sensitive Three poles (three phase) RF200 - RF420 B115-B400 G372 G373 G375 G376 Order code Adjustment Protection Qty Wt range fuses per am gg pkg [A] [A] [A] n [kg] MANUAL OR AUTOMATIC RESETTING. Independent screw fixing or direct mounting on contactors: B115-B145-B180 using G372 links B250-B310-B400 using G373 links RF RF RF RF Independent screw fixing or direct mounting on contactors: B145-B180 using G375 links B250-B310-B400 using G376 links RF RF RF NOTE: The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. RELAYS FOR B500 AND B630 CONTACTORS MANUAL OR AUTOMATIC RESETTING. Contact our Customer Service or sales@mechtric.com.au for the relative order codes and detailed information. Three-phase motor powers 230V 400V 415V 440V 550V 690V [kw] [kw] [kw] [kw] [kw] [kw] NOTE: For 1000V powers, contact our Customer Service or sales@mechtric.com.au The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. Certifications and compliance Certifications obtained: Type RF200 RF420 Certified products. c U L u s G O S T Compliant with standards: IEC/EN , IEC/EN , UL508, CSA C22.2 n 14. RF200 RF420 PAGE 2-16

18 Add-on blocks and accessories for thermal overload relays RFX38 02 RFX G262 RFX38 04 Order code For relay Qty Wt per pkg n [kg] Set of links for direct contactor mounting. 11 G372 RF on B115-B145-B G373 contactor B250-B310-B G375 RF on B145-B G376 contactor B250-B310-B Protection cover for thermal overload relay-contactor assembly. RFX38 02 RF38 on contactor BF BF12 - BF18 - BF25 RFX38 03 RF38 on contactor BF BF32 - BF38 Protection shrouds for power terminals. 11 G262 For RF G361 RF G363 RF Independent mounting. Screw fixing or 35mm DIN rail (IEC/EN 60715) mounting. RFX38 04 RF G270 RF Electrical reset. 11 G228 RF RF Sealing device. RFX38 01 RF RF RF G233 RF RF Electric button NO. 11 G244 RF RF Marking element. 11 RB6 RF RF Set of 100 alphanumeric symbol RF RF Front IP20 protection is warranted to contactor-thermal relay connections. Independent mounting base for any RF95 relay. Remove the links fixed on RF...95 and use those supplied with the base. Replace with voltage digit. Standard voltages are: AC 50/60Hz 24V / 48V / V / V / V. Replace with the required alphanumeric symbol. Each package contains 100 pieces of the same symbol. Electrical reset (G228) operational characteristics Control circuit voltage AC (50/60Hz) V Power consumption in AC VA 300 Minimum reset time ms 20 NOTE: Coils can remain supplied for a maximum interval of 500ms; 3 consecutive operations are allowed, followed by a 5 minute interval. To see the recommended wiring diagram, refer to Certifications and compliance Certifications obtained: c U G L C O u S S Tipo G361 G363 s A T G372 G373 G375 G376 G270 RFX38 04 Certified products. Recognised. Products having this type of marking are intended for use as components of complete workshop-assembled equipment. Compliant with standards: IEC/EN , IEC/EN , UL508, CSA C22.2 n G G244 Combinations G262 (per RF ) G372 G373 G375 G376 G270 G361 G363 RF RF RFX38 01 RFX38 04 RF G233 G228 RF...9 RB G244 RF...38 RFX38 01 PAGE 2-17

19 Add-on blocks and accessories for thermal relays Electronic relay and accessory Protection cover for thermal overload relay-contactor assembly BF09-BF25 BF26-BF38 RFX38 02 RFX38 03 RF...38 RF...38 Thermistor protection relay 31 DRPT Order code Rated auxiliary Qty Wt. supply voltage per pkg [V] DC supply (version for 35 mm DIN rail IEC/EN 60715). n [kg] 31 DRPTC 24 24VDC AC supply (version for 35 mm DIN rail IEC/EN 60715). 31 DRPT 24 24VAC DRPT VAC DRPT VAC ACCESSORY Order code Description Qty Wt per pkg n [kg] 31 CE106 Adapter for screw fixing of DRPT relay on mounting plate. Galvanic isolation between supply and internal circuit does not exist. General characteristics The DRPT is a thermal protection relay of motors equipped with thermistor PTC sensors immersed in the winding heads. The maximum number of thermistors to be used is limited by the resistance of all the sensors connected in series; total ohmic value is not to exceed 1.5kΩ at 25 C. The DRPT type has fail-safe operation: the protective feature trips even in the case the PTC circuit is disconnected or there is a lack of voltage. Operational characteristics Supply circuit Rated frequency: 50-60Hz for AC types only Operational limits: Us Maximum heat dissipation: 2.5W Connection: permanent. Measuring circuit Type of connectable PTC sensor: According to DIN Total PTC resistance at 25 C: 1.5kΩ Tripping resistance: kΩ Resetting resistance: kΩ Voltage at PTC terminals: 2.5VDC. Remote resetting Control: NC contact opening Contact voltage: 5VDC Current consumption: about 1mA. Output relay Arrangement: 1 relay with 2 changeover contacts Rated operational voltage Ue: 250VAC Conventional free air thermal current Ith: 5A Designation to IEC/EN : B300 Mechanical life: 50x10 6 cycles Electrical life (with rated load): 2x10 5 cycles. Indications Green LED indicator for power ON Red LED indicator for relay state TRIP Ambient conditions Operating temperature: C Storage temperature: C. Housing Snap on 35mm DIN rail (IEC/EN 60715) For screw fixing, use CE106 adapter Degree of protection IP40 housing IP20 terminals. Certifications and compliance Certifications obtained: GOST. Compliant with standards: IEC/EN PAGE 2-18

20 Thermal Overload Relays Dimensions [mm (in)] ACCESSORIES FOR THERMAL OVERLOAD RELAYS RFX38 04 base c/w RF...38 thermal relay 7.9 (0.31 ) 45 (1.77 ) 14.6 (0.57 ) 34 (1.34 ) Ø4.2 (0.16 ) 88.4 (3.48 ) 83 (3.27 ) G270 base c/w RF...82 and RF...95 thermal relay 9.7 (0.38 ) 55 (2.16 ) 16.5 (0.65 ) 43 (1.69 ) Ø4.2 (0.16 ) 102 (4.01 ) 95.4 (3.75 ) 70.3 (2.77 ) 73.5 (2.89 ) 79 (3.11 ) 85 (3.35 ) 7.9 (0.31 ) 14.6 (0.57 ) THERMAL RELAYS WITH LINKS RF with G372 and G (0.43 ) 16.5 (0.65 ) 23.8 (0.94 ) (5.02 ) 40 (1.57 ) 40 (1.57 ) (6.54 ) 122 (4.80 ) G372 G (4.46 ) 74 (2.91 ) 172 (6.77 ) 38.6 (1.52 ) Ø5.4 (0.21 ) 20 (0.79 ) 40 (1.57 ) 40 (1.57 ) M (2.22 ) RF with G375 and G (0.98 ) 145 (5.71 ) 47.5 (1.57 ) 47.5 (1.57 ) (6.51 ) (6.03 ) G375 G376 Ø5.4 (0.21 ) (4.77 ) 74 (2.91 ) (7.46 ) 44.8 (1.76 ) 25 (0.98 ) 47.5 (1.57 ) 47.5 (1.57 ) M (2.24 ) ADD-ON BLOCKS FOR THERMAL OVERLOAD RELAYS RF...9, RF...82 and RF...95 G reset G244 button 19 (0.75 ) 13.3 (0.52 ) 10 (0.39 ) 35.8 (1.41 ) 35.8 (1.41 ) 26.7 (1.05 ) THERMISTOR PROTECTION RELAY DRPT 45 (1.77 ) 100 (3.94 ) CE106 adapter 22.5 (0.88 ) 10 (0.39 ) 79 (3.11 ) 84 (3.30 ) 94 (3.70 ) Ø4.5 (0.18 ) PAGE 2-19

21 AC Fuse Holders Fuse holders UL Recognised and CSA certified FB01 A FB02 A FB03 A FB01 A 1PL FB02 A 1PL FB03 A 1PL Order Pole Status DIN Qty Wt code arrange- indicator size per ment pkg n n [kg] For 10x38mm fuses. IEC 32A rated current at 690VAC. FB01 F 1P 1P FB01 F 1PL 1P YES FB01 A 1M 1P+N FB01 F 1N 1P+N FB01 F 2P 2P FB01 F 3P 3P FB01 F 3N 3P+N For 14x51mm fuses. IEC 50A rated current at 690VAC. FB02 A 1P 1P FB02 A 1PL 1P YES FB02 A 1N 1P+N FB02 A 2P 2P FB02 A 3P 3P FB02 A 3N 3P+N For 22x58mm fuses. IEC 125A rated current at 690VAC. FB03 A 1P 1P FB03 A 1PL 1P YES FB03 A 1N 1P+N FB03 A 2P 2P FB03 A 3P 3P FB03 A 3N 3P+N Use with gg/am class 125A fuses, not dissipating more than 12W power. NOTE: For FB01 F type: UL Recognized as Fuseholders - Component. Current rating: 30A. Voltage rating: 750V max. CSA certified as Fuseholder Assemblies. Current rating: 30A. Voltage rating: 600V max. For FB02 A type: UL Recognized as Fuseholders - Component. Current rating: 50A. Voltage rating: 750V max. For FB03 A type: UL Recognized as Fuseholders - Component. Current rating: 100A. Voltage rating: 750V max. Operational characteristics IEC rated voltage Ue: 690VAC (FB01 A 1M excluded) 400VAC (FB01 A 1M only) IEC rated current Ie: FB01 A 1M: 32A FB01 F: 32A FB02 A: 50A FB03 A: 125A IEC utilisation category: FB01 A 1M: AC22B 400V FB01 F: AC22B 500V, AC21B 690V FB02 A: AC22B 500V, AC21B 690V FB03 A: AC21B 690V Suitable for IEC fuse class: gg and am IEC degree of protection: IP20. Certifications and compliance Certifications obtained: CSA certified (File class 6255) Type FB01 F... FB02 A... FB03 A... Certification obtained. UL Recognized : Products having this type of marking are intended for use as components of complete workshop-assembled equipment. Compliant with standards: IEC/EN , IEC/EN , IEC/EN , IEC/EN , UL , UL , CSA C22.2 n , CSA C22.2 n UL Recognized for USA and Canada (culus - File E343395) Fuse holders FB01 B FB01 B 1PL Order Pole Status DIN Qty Wt code arrange- indicator size per ment pkg n n [kg] For 10x38mm fuses. IEC 32A rated current at 690VAC. FB01 B 1P 1P FB01 B 1PL 1P YES FB01 B 1N 1P+N FB01 B 2P 2P FB01 B 3P 3P FB01 B 3N 3P+N Operational characteristics IEC rated voltage Ue: 690VAC IEC rated current Ie: 32A IEC utilisation category: AC22B 500V, AC21B 690V Suitable for IEC fuse class: gg and am IEC degree of protection IP20. Reference standards Compliant with standards: IEC/EN , IEC/EN , IEC/EN , IEC/EN PAGE 2-20

22 DC Fuse Holders for Photovoltaic Applications Accessories Fuse holders for photovolatic applications UL Listed / CSA certified FB01 D FB01 D 1PL Fuse for photovoltaic applications FE01 D Accessories FBX 00 FBX 01 FBX 02 FBX 03 P1X P1X P1X P1X Order Pole Status DIN Qty Wt code arrange- indicator size per ment pkg n n [kg] For 10x38mm fuses. IEC 32A rated current at 1000VDC. FB01 D 1P 1P FB01 D 1PL 1P YES FB01 D 2P 2P FB01 D 2PL 2P YES NOTE: UL Listed and CSA certified as Photovoltaic fuseholders for use with Photovoltaic Fuses. Interrupting rating 30,000 DC Amps. Voltage rating 1000V. Current rating 30A. Order Rated current Qty Wt code In per pkg [A] n [kg] For 10x38mm fuses. IEC 30kA breaking capacity at 1000VDC. FE01 D FE01 D FE01 D FE01 D FE01 D FE01 D FE01 D FE01 D Order Description Qty Wt code per pkg [A] n [kg] FBX 00 Coupling clip for 10x38, x51 and 22x58mm sizes FBX 01 Coupling pin for x38mm size type FB01 A1M, FB01 B1P and FB01 B1PL only FBX 02 Coupling pin for 14x and 22x58mm sizes FBX 03 Coupling pin for 10x38mm size types FB01 F, FB01 G, FB01 D only For FB01 F, FB01 A1M, FB01 B and FB01 G types, AC duty. P1X phase connection busbar for 57 modules in total, 996mm/39.2 long P1X phase connection busbar for 60 modules in total, 1060mm/41.7 long P1X Kit of 5 isolating covers for unused busbar terminals P1X End cap for 1-phase P1X9031 busbar P1X End cap for 3-phase P1X9033 busbar P1X pole terminal for busbar supply, 25mm²max conductor P1X pole terminal for busbar supply, 50mm²max conductor See technical characteristics under derating factor of FB01 type for operating conditions. Operational characteristics IEC rated voltage Ue: 1000VDC IEC rated current Ie: 32A IEC utilisation category: DC20B 1000VDC Suitable for IEC fuse class: gpv IEC degree of protection: IP20. Certifications and compliance Certifications obtained: UL Listed for USA (UL - File E366062) and CSA certified for Canada (file ref. not available at time of catalogue printing). Compliant with standards: IEC/EN , IEC/EN , IEC/EN , IEC/EN , UL , UL , CSA C22.2 n , CSA C22.2 n Operational characteristics IEC rated voltage Ue: 1000VDC IEC rated current Ie: 2-20A IEC fuse class: gpv. Reference standards Compliant with standards: IEC/EN General and operational characteristics SUPPLY CONNECTION BUSBARS Central point of power supply: 100A max Side point of power supply: 63A max Pitch: 18mm/0.7 Busbar section: 10mm 2 For paralleling connection Length can be cut in shorter sections. Fuse holder combinations FB01... FBX 00 FB01... FBX 00 FBX 00 FB02... FB02... FB03... FBX 03 FBX 01 FBX 02 FBX 02 FB03... PAGE 2-21

23 Fuse Holders Technical characteristics TYPE FB01 A... FB01 B... FB02 A... FB03 A... FB01 C... FB01 D... Range AC Class CC (AC) DC IEC maximum rated current In 32A 50A 125A 30A 32A IEC maximum rated voltage Un 690VAC; 690VAC 600VAC 1000VDC 400VAC IEC utilisation category AC22B 500V; AC21B 690V; AC21B 690V AC22B 500V; DC20B 1000VDC AC22B 400V AC21B 690V Maximum power dissipation 3W 5W 9.5W 3W 4W Derating factor of current In 20 C 1 for different ambient temperatures 30 C C C C C 0.5 Derating factor of current In for side-by-side fuse holders number of poles Voltage for status indicator VAC VAC VAC VDC CONNECTIONS Maximum tightening torque 2.5Nm; 2Nm / 22lbin 3Nm / 26lbin 4Nm / 35lbin 2.5Nm / 22lbin Maximum conductor flexible/stranded 1x16mm 2 ; 1-16mm 2 / 8AWG 1x25mm 2 / 6AWG 1x35mm 2 / 2AWG 1x16mm 2 / 8AWG 1x16mm 2 / 6AWG cross section rigid/solid 1x25mm 2 ; 1-10mm 2 / 8AWG 1x35mm 2 / 8AWG 1x50mm 2 / 1AWG 1x25mm 2 / 10AWG 1x25mm 2 / 4AWG AMBIENT CONDITIONS Operating temperature C Storage temperature C Maximum altitude 3,000m Operation position Any Fixing On 35mm DIN rail (IEC/EN 60715) Values valid only for FB01 A 1M type. Use with gg/am class 125A fuses, not dissipating more than 12W power. TECHNICAL CHARACTERISTICS FOR FE01 D... FUSES TYPE Rated current Power consumption at 0.7 In Power consumption at In Prearcing I 2 t Total I 2 t at 1000VDC [A] [W] [W] [A 2 s] [A 2 s] FE01 D FE01 D FE01 D FE01 D FE01 D FE01 D FE01 D FE01 D TIME-CURRENT CHARACTERISTICS FOR FE01 D... FUSES A 4A 6A 8A 10A 12A 16A 20A PREARCING TIME [s] PROSPECTIVE CURRENT [A rms] PAGE 2-22

24 Miniature Circuit Breakers 1 to 63A MCB 6KA ETIMAT 6kA 1P 1 pole, 1 pole + N and 3 pole Trip characteristics B and C curve (optional D curve) Accessories for remote indication and release IEC rated current In 1 to 63A 18mm wide module Auxiliary contacts and shunt trip release options Fixing on 35mm DIN rail (IEC/EN 60715) 1 pole B curve Order Code Curve IEC In IEC Icn No. of DIN modules Weight Type (A) (ka) (kg) ETI B ETI B ETI B ETI B ETI B ETI B ETI B ETI B ETI B ETI B pole C curve ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C General characteristics These devices are used to protect against short circuits and overloads of wiring installations and loads in panel boards, office buildings, stores, and similar applications. Their purpose is circuit protection, circuit isolation and load operation controls. They have instantaneous trip characteristics defined as follows: B-type: Instantaneous trip 3-5 times In For non-inductive or low inductive loads (heating resistors, generators, very long wire lines) C-type: Instantaneous trip 5-10 times In For inductive loads (mixed loads, resistive and inductive with low inrush current) D-type: Instantaneous trip times In For highly inductive loads (loads with high inrush and current such as motors). Specifications Rated voltage: 230/440VAC, max. 60VDC Rated current: B: 6-63A, C: 1-63A Rated frequency: 50/60Hz Rated short circuit capacity: 6kA Energy limiting class: 3; B, C Tripping characteristics: B, C and (D optional) Terminals: 1-25mm 2, max. 3 Nm Module width: 18mm/pole Sealing possibility: On/Off Electrical life: 4,000 operations Mechanical life: 10,000 operations Operating Temp.: -40 to +70 C For detailed tripping curves see the information on our web site Compliance and standards Certifications obtained: CE, VDE, KEMA, SAA Certificate No. SAA EA Compliant with standards: IEC 60898, EN60898, AS/NZS :2004 PAGE 2-23

25 Miniature Circuit Breakers 1 to 63A MCB 6KA ETIMAT 6kA 1P+N ETIMAT 6kA 3P 1 pole +N C curve Order Code Curve IEC In IEC Icn No. of DIN modules Weight Type (A) (ka) (kg) ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C pole C curve ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C Specifications Rated voltage: 230/440VAC, max. 60VDC Rated current: B: 6-63A, C: 1-63A Rated frequency: 50/60Hz Rated short circuit capacity: 6kA Energy limiting class: 3; B, C Tripping characteristics: B, C and (D) Terminals: 1-25mm 2, max. 3 Nm Module width: 18mm/pole Sealing possibility: On/Off Electrical life: 4,000 operations Mechanical life: 10,000 operations Operating Temp.: -40 to +70 C For detailed tripping curves see the information on our web site Compliance and standards Certifications obtained: CE, VDE, KEMA, SAA Certificate No. SAA EA Compliant with standards: IEC 60898, EN60898, AS/NZS :2004 Accessories Auxiliary Switch Order Code Contact No. of DIN Weight modules (kg) ETI NO+NC ETI x NC ETI x NO Shunt Trip Release Auxiliary Switch Shunt Trip Release Order Code Voltage No. of DIN Weight modules (kg) ETI VAC ETI VAC/DC PAGE 2-24

26 Miniature Circuit Breakers 1 to 63A MCB 10KA P2 MB 1P... 1 pole, 2 pole, 3 pole and 4 pole Thermal and magnetic trip Trip characteristics B, C and D curve Accessories for remote indication and release IEC rated current In 1 to 63A 17.5mm wide module Auxiliary contacts and shunt trip release options Fixing on 35mm DIN rail (IEC/EN 60715) 1 pole B curve Order Code Curve IEC In IEC Icn No. of DIN modules Weight Type (A) (ka) (kg) P1 MB 1P B01 B P1 MB 1P B02 B P1 MB 1P B04 B P1 MB 1P B06 B P1 MB 1P B10 B P1 MB 1P B16 B P1 MB 1P B20 B P1 MB 1P B25 B P1 MB 1P B32 B P1 MB 1P B40 B P1 MB 1P B50 B P1 MB 1P B63 B pole C curve P1 MB 1P C01 C P1 MB 1P C02 C P1 MB 1P C04 C P1 MB 1P C06 C P1 MB 1P C10 C P1 MB 1P C16 C P1 MB 1P C20 C P1 MB 1P C25 C P1 MB 1P C32 C P1 MB 1P C40 C P1 MB 1P C50 C P1 MB 1P C63 C pole D curve P1 MB 1P D01 D P1 MB 1P D02 D P1 MB 1P D04 D P1 MB 1P D06 D P1 MB 1P D10 D P1 MB 1P D16 D P1 MB 1P D20 D P1 MB 1P D25 D P1 MB 1P D32 D P1 MB 1P D40 D P1 MB 1P D50 D P1 MB 1P D63 D See page 2-26 for add on blocks and accessories. General characteristics These devices are used to protect against short circuits and overloads of wiring installations and loads in panel boards, office buildings, stores, and similar applications. Their purpose is circuit protection, circuit isolation and load operation controls. They have instantaneous trip characteristics defined as follows: B-type: Instantaneous trip 3-5 times In For non-inductive or low inductive loads (heating resistors, generators, very long wire lines) C-type: Instantaneous trip 5-10 times In For inductive loads (mixed loads, resistive and inductive with low inrush current) D-type: Instantaneous trip times In For highly inductive loads (loads with high inrush and current such as motors). Specifications Rated voltage: 230/440VAC, max. 60VDC Rated current: 1-63A Rated frequency: 50/60Hz Rated short circuit capacity: 10kA Impulse withstand voltage: 4kV Tripping characteristics: B, C and D Terminals: 1-16mm 2, max. 2 Nm Module width: 17.5mm/pole Dissipation per pole: 3-13W Electrical life: 4,000 operations Mechanical life: 20,000 operations Operating Temp.: -35 to +75 C For detailed tripping curves see the information on our web site Compliance and standards Certifications obtained: TÜV Rheinland; UL Recognised for USA and Canada (curus File E359585) as Supplementary Protectors, designated as Overcurrent type, for general industrial use, suitable for factory wiring only with % tripping current of amp rating. Products having this type of marking are intended for use as components of complete workshop- assembled equipment. Compliant with standards: IEC/EN , IEC/EN , UL 1077, CSA C22.2 n 235. PAGE 2-25

27 Miniature Circuit Breakers 1 to 63A MCB 10KA P1 MB 2P... 2 pole B curve Order Code Curve IEC In IEC Icn No. of DIN modules Weight Type (A) (ka) (kg) P1 MB 2P B01 B P1 MB 2P B02 B P1 MB 2P B04 B P1 MB 2P B06 B P1 MB 2P B10 B P1 MB 2P B16 B P1 MB 2P B20 B P1 MB 2P B25 B P1 MB 2P B32 B P1 MB 2P B40 B P1 MB 2P B50 B P1 MB 2P B63 B pole C curve P1 MB 2P C01 C P1 MB 2P C02 C P1 MB 2P C04 C P1 MB 2P C06 C P1 MB 2P C10 C P1 MB 2P C16 C P1 MB 2P C20 C P1 MB 2P C25 C P1 MB 2P C32 C P1 MB 2P C40 C P1 MB 2P C50 C P1 MB 2P C63 C pole D curve P1 MB 2P D01 D P1 MB 2P D02 D P1 MB 2P D04 D P1 MB 2P D06 D P1 MB 2P D10 D P1 MB 2P D16 D P1 MB 2P D20 D P1 MB 2P D25 D P1 MB 2P D32 D P1 MB 2P D40 D P1 MB 2P D50 D P1 MB 2P D63 D See page 2-26 for add on blocks and accessories. Specifications Rated voltage: 230/440VAC, max. 60VDC Rated current: 1-63A Rated frequency: 50/60Hz Rated short circuit capacity: 10kA Impulse withstand voltage: 4kV Tripping characteristics: B, C and D Terminals: 1-16mm 2, max. 2 Nm Module width: 17.5mm/pole Dissipation per pole: 3-13W Electrical life: 4,000 operations Mechanical life: 20,000 operations Operating Temp.: -35 to +75 C For detailed tripping curves see the information on our web site Compliance and standards Certifications obtained: TÜV Rheinland; UL Recognised for USA and Canada (curus File E359585) as Supplementary Protectors, designated as Overcurrent type, for general industrial use, suitable for factory wiring only with % tripping current of amp rating. Products having this type of marking are intended for use as components of complete workshop- assembled equipment. Compliant with standards: IEC/EN , IEC/EN , UL 1077, CSA C22.2 n 235. PAGE 2-26

28 Miniature Circuit Breakers 1 to 63A MCB 10KA P1 MB 3P... 3 pole B curve Order Code Curve IEC In IEC Icn No. of DIN modules Weight Type (A) (ka) (kg) P1 MB 3P B01 B P1 MB 3P B02 B P1 MB 3P B04 B P1 MB 3P B06 B P1 MB 3P B10 B P1 MB 3P B16 B P1 MB 3P B20 B P1 MB 3P B25 B P1 MB 3P B32 B P1 MB 3P B40 B P1 MB 3P B50 B P1 MB 3P B63 B pole C curve P1 MB 3P C01 C P1 MB 3P C02 C P1 MB 3P C04 C P1 MB 3P C06 C P1 MB 3P C10 C P1 MB 3P C16 C P1 MB 3P C20 C P1 MB 3P C25 C P1 MB 3P C32 C P1 MB 3P C40 C P1 MB 3P C50 C P1 MB 3P C63 C pole D curve P1 MB 3P D01 D P1 MB 3P D02 D P1 MB 3P D04 D P1 MB 3P D06 D P1 MB 3P D10 D P1 MB 3P D16 D P1 MB 3P D20 D P1 MB 3P D25 D P1 MB 3P D32 D P1 MB 3P D40 D P1 MB 3P D50 D P1 MB 3P D63 D See page 2-26 for add on blocks and accessories. Specifications Rated voltage: 230/440VAC, max. 60VDC Rated current: 1-63A Rated frequency: 50/60Hz Rated short circuit capacity: 10kA Impulse withstand voltage: 4kV Tripping characteristics: B, C and D Terminals: 1-16mm 2, max. 2 Nm Module width: 17.5mm/pole Dissipation per pole: 3-13W Electrical life: 4,000 operations Mechanical life: 20,000 operations Operating Temp.: -35 to +75 C For detailed tripping curves see the information on our web site Compliance and standards Certifications obtained: TÜV Rheinland; UL Recognised for USA and Canada (curus File E359585) as Supplementary Protectors, designated as Overcurrent type, for general industrial use, suitable for factory wiring only with % tripping current of amp rating. Products having this type of marking are intended for use as components of complete workshop- assembled equipment. Compliant with standards: IEC/EN , IEC/EN , UL 1077, CSA C22.2 n 235. PAGE 2-27

29 Miniature Circuit Breakers 1 to 63A MCB 10KA P1 MB 4P... 4 pole B curve Order Code Curve IEC In IEC Icn No. of DIN modules Weight Type (A) (ka) (kg) P1 MB 4P B01 B P1 MB 4P B02 B P1 MB 4P B04 B P1 MB 4P B06 B P1 MB 4P B10 B P1 MB 4P B16 B P1 MB 4P B20 B P1 MB 4P B25 B P1 MB 4P B32 B P1 MB 4P B40 B P1 MB 4P B50 B P1 MB 4P B63 B pole C curve P1 MB 4P C01 C P1 MB 4P C02 C P1 MB 4P C04 C P1 MB 4P C06 C P1 MB 4P C10 C P1 MB 4P C16 C P1 MB 4P C20 C P1 MB 4P C25 C P1 MB 4P C32 C P1 MB 4P C40 C P1 MB 4P C50 C P1 MB 4P C63 C pole D curve P1 MB 4P D01 D P1 MB 4P D02 D P1 MB 4P D04 D P1 MB 4P D06 D P1 MB 4P D10 D P1 MB 4P D16 D P1 MB 4P D20 D P1 MB 4P D25 D P1 MB 4P D32 D P1 MB 4P D40 D P1 MB 4P D50 D P1 MB 4P D63 D See page 2-26 for add on blocks and accessories. Specifications Rated voltage: 230/440VAC, max. 60VDC Rated current: 1-63A Rated frequency: 50/60Hz Rated short circuit capacity: 10kA Impulse withstand voltage: 4kV Tripping characteristics: B, C and D Terminals: 1-16mm 2, max. 2 Nm Module width: 17.5mm/pole Dissipation per pole: 3-13W Electrical life: 4,000 operations Mechanical life: 20,000 operations Operating Temp.: -35 to +75 C For detailed tripping curves see the information on our web site Compliance and standards Certifications obtained: TÜV Rheinland; UL Recognised for USA and Canada (curus File E359585) as Supplementary Protectors, designated as Overcurrent type, for general industrial use, suitable for factory wiring only with % tripping current of amp rating. Products having this type of marking are intended for use as components of complete workshop- assembled equipment. Compliant with standards: IEC/EN , IEC/EN , UL 1077, CSA C22.2 n 235. PAGE 2-28

30 Miniature Circuit Breakers 80 to 125A MCB 10KA P2 MB 1P... P2 MB 2P... 1 pole, 2 pole, 3 pole and 4 pole Thermal and magnetic trip Trip characteristics C and D curve Accessories for remote indication and release IEC rated current In 80 to 125A 27mm wide module Auxiliary contacts and shunt trip release options Fixing on 35mm DIN rail (IEC/EN 60715) 1 pole C curve Order Code Curve IEC In IEC Icn No. of DIN modules Weight Type (A) (ka) (kg) P2 MB 1P C080 C P2 MB 1P C100 C P2 MB 1P C125 C pole C curve P2 MB 2P C080 C P2 MB 2P C100 C P2 MB 2P C125 C pole C curve P2 MB 3P C080 C P2 MB 3P C100 C P2 MB 3P C125 C pole D curve P2 MB 3P D080 D P2 MB 3P D100 D P2 MB 3P D125 D pole C curve P2 MB 4P C080 C P2 MB 4P C100 C P2 MB 4P C125 C pole D curve P2 MB 4P D080 D P2 MB 4P D100 D P2 MB 4P D125 D See page 2-26 for add on blocks and accessories. General characteristics These devices are used to protect against short circuits and overloads of wiring installations and loads in industrial applications. Their purpose is circuit protection, circuit isolation and load operation controls. They have instantaneous trip characteristics defined as follows: C-type: Instantaneous trip 5-10 times In For inductive loads (mixed loads, resistive and inductive with low inrush current) D-type: Instantaneous trip times In For highly inductive loads (loads with high inrush and current such as motors). Specifications Rated voltage: 230/440VAC, max. 60VDC Rated current: 1-63A Rated frequency: 50/60Hz Rated short circuit capacity: 10kA Impulse withstand voltage: 4kV Tripping characteristics: C and D Terminals: mm 2, max. 3 Nm Module width: 27mm/pole Dissipation per pole: 15-20W Electrical life: 4,000 operations Mechanical life: 10,000 operations Operating Temp.: -35 to +75 C For detailed tripping curves see the information on our web site Compliance and standards Certifications obtained: TÜV Rheinland; UL Recognised for USA and Canada (curus File E359585) as Supplementary Protectors, designated as Overcurrent type, for general industrial use, suitable for factory wiring only with % tripping current of amp rating. Products having this type of marking are intended for use as components of complete workshop- assembled equipment. Compliant with standards: IEC/EN , IEC/EN , UL 1077, CSA C22.2 n 235. P2 MB 3P... P2 MB 4P... PAGE 2-29

31 Miniature and Residual Circuit Breakers Add-on blocks and accessories Add-on blocks for P1MB miniature circuit breakers 1-63A P1X 1011 P1X Order code Characteristics Qty Qty Wt per per MCB pkg n n [kg] Auxiliary contact. P1X 1011 One changeover (SPDT), side mount Indicator contact for thermal-magnetic trip. P1X 1311 One changeover (SPDT), side mount Undervoltage trip release. P1X V 50/60Hz, side mount Shunt trip release. P1X V /60Hz, side mount General characteristics Auxiliary and indicator contact width: 9mm / 0.35 (0.5 module) Undervoltage and shunt trip release width: 17.5mm / 0.69 Maximum combination: 3 add-on blocks on MCB left side only of which 1 undervoltage or shunt release directly on MCB side and then 2 contacts of which 1 auxiliary and 1 indicator. Operational characteristics IEC rated impulse voltage Uimp: 4kA IEC rated operational current in AC: 6A 230V for releases; 3A 400V for auxiliary contacts. Certifications and compliance Certifications obtained: UL Recognized for USA and Canada (curus File E359585) as Accessories for supplementary protectors. Products having this type of marking are intended for use as components of complete workshop- assembled equipment. Compliant with standards: IEC/EN Add-on blocks for P2MB miniature circuit breakers A Order code Characteristics Qty Qty Wt per per MCB pkg n n [kg] Auxiliary contact. P2X 1011 One changeover (SPDT), side mount Indicator contact for thermal-magnetic trip. P2X 1311 One changeover (SPDT), side mount Undervoltage trip release. P2X V 50/60Hz, side mount General characteristics Auxiliary and indicator contact width: 9mm / 0.35 (0.5 module) Undervoltage and shunt trip release width: 17.5mm / 0.69 Maximum combination: 3 add-on blocks on MCB sides of which 1 undervoltage or shunt release on MCB right side and 2 contacts on the left of which 1 auxiliary and 1 indicator. Operational characteristics IEC rated impulse voltage Uimp: 4kA IEC rated operational current in AC: 6A 230V for releases; 3A 400V for auxiliary contacts. Reference standards Compliant with standards: IEC/EN P2X 1011 P2X 1311 Accessories for P1MB types P1X P1X Order code Description Qty Wt per pkg n [kg] P1X phase connection busbar for 55 1P modules (55 1P MCBs in total), 966mm/39.2 long P1X phase connection busbar for 60 modules (20 3P MCBs in total), 1060mm/41.7 long P1X Kit of 5 isolating covers for unused busbar terminals P1X End cap for 1-phase P1X9031 busbar P1X End cap for 3-phase P1X9033 busbar P1X pole terminal for busbar supply, 25mm² max conductor P1X pole terminal for busbar supply, 50mm² max conductor General and operational characteristics SINGLE-PHASE SUPPLY BUSBAR Central point of power supply: 100A max Side point of power supply: 63A max Pitch: 17.5mm / 0.69 Busbar section: 10mm² Number of modules/poles: 55 For paralleling connection Standard-supplied length: 966mm/39.2 which can be cut in shorter sections. THREE-PHASE SUPPLY BUSBAR Central point of power supply: 100A max Side point of power supply: 63A max Pitch: 17.5mm / 0.69 Busbar section: 10mm² Number of modules/poles: 60 (20pcs 3P MCBs) For paralleling connection Standard-supplied length: 1060mm/41.7 which can be cut in shorter sections. P1X P1X PAGE 2-30

32 Residual Current Circuit Breakers EFI-2 RCCB EFI A 2 pole (1P + N) Instantaneous break time (short time delayed and selective optional) Rated residual current 30mA (100mA and 300mA optional) Type A (sinusoidal AC and pulsating DC) IEC rated current In 16 to 100A 36mm wide module Fixing on 35mm DIN rail (IEC/EN 60715) 2 pole 30mA Type A Order Code IEC In (A) No. of DIN modules Weight (kg) ETI ETI ETI ETI ETI ETI General characteristics The EFI-2 residual current circuit breakers detect and trip in the event of residual current. Used for the protection against indirect or direct contact with live conductors or parts in network systems where the neutral and earth conductors are separated. They have instantaneous trip characteristics with maximum break time of 40ms. Specifications Rated voltage: 230V/415 AC Rated current: A Rated frequency: 50/60Hz Conditional short circuit current: 10kA Rated making and breaking capacity: 800A Rated residual current: 30mA (100mA and 300mA optional) Residual current sensitivity: A Terminals: 1-25mm 2, (1-35mm 2 100A) max. 1.5 Nm Module width: 36mm / 72mm Electrical life: 2,000 operations Mechanical life: 4,000 operations Operating Temp.: - 25 to +55 C Compliance and standards Certifications obtained: CE, VDE, KEMA, SAA Certificate No. SAA EA Compliant with standards: IEC 61008, AS/NZS :2011 EFI-2 100A EFI-4 RCCB 4 pole (3P + N) Instantaneous break time (short time delayed and selective optional) Rated residual current 30mA (100mA and 300mA optional) Type A (sinusoidal AC and pulsating DC) IEC rated current In 16 to 100A 72mm wide module Fixing on 35mm DIN rail (IEC/EN 60715) EFI A 4 pole 30mA Type A Order Code IEC In (A) No. of DIN modules Weight (kg) ETI ETI ETI ETI ETI ETI EFI-4 100A PAGE 2-31

33 Residual Current Circuit Breakers with Overcurrent Protection KZS-1M RCBO 6KA KZS-1M 2 pole (L+N) Trip characteristics B and C curve Rated residual current 30mA (10mA and 100mA optional) Type A (sinusoidal AC and pulsating DC) IEC rated current In 6 to 25A 18mm wide module Fixing on 35mm DIN rail (IEC/EN 60715) 2 pole B curve 30mA Order Code Curve IEC In IEC Icn No. of DIN modules Weight Type (A) (ka) (kg) ETI B ETI B ETI B ETI B ETI B ETI B pole C curve 30mA ETI C ETI C ETI C ETI C ETI C ETI C General characteristics The KZS-1M residual current circuit breakers with integral over-current protection, detect and trip in the event of residual current and protect circuits in the case of short circuits and overcurrent. From a practical point of view, RCBOs integrate both functions of MCB and of RCCB, functionally dependant on the line voltage (min 90V). Used for the protection against indirect or direct contact with live conductors or parts in network systems where the neutral and earth conductors are separated. They have instantaneous trip characteristics defined as follows: B-type: Instantaneous trip 3-5 times In For non-inductive or low inductive loads (heating resistors, generators, very long wire lines) C-type: Instantaneous trip 5-10 times In For inductive loads (mixed loads, resistive and inductive with low inrush current) Specifications Rated voltage: 230V AC Min. supply voltage: 90V Rated current: 6-25A Rated frequency: 50/60Hz Rated short circuit capacity: 6kA Rated residual current: 30mA (10mA and 100mA optional) Tripping characteristics: B and C Terminals: 1-10mm 2, max. 1.5 Nm Module width: 18mm Electrical life: 2,000 operations Mechanical life: 4,000 operations Operating Temp.: -25 to +55 C For detailed tripping curves see the information on our web site Compliance and standards Certifications obtained: CE, VDE, KEMA, SAA Certificate No. SAA EA Compliant with standards: IEC 61009, AS/NZS :2011 PAGE 2-32

34 Residual Current Circuit Breakers with Overcurrent Protection KZS-2M RCBO 10KA KZS-2M 2 pole (L+N) Trip characteristics C curve (B curve optional) Rated residual current 30mA (10mA and 300mA optional) Type AC (pure sinusoidal current) and type A (sinusoidal AC and pulsating DC) IEC rated current In 6 to 40A 36mm wide module Fixing on 35mm DIN rail (IEC/EN 60715) 2 pole C curve 30mA Type A Order Code Curve IEC In IEC Icn No. of DIN modules Weight Type (A) (ka) (kg) ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C pole C curve 30mA Type AC ETI C ETI C ETI C ETI C ETI C ETI C ETI C ETI C General characteristics The KZS-2M residual current circuit breakers with integral over-current protection, detect and trip in the event of residual current and protect circuits in the case of short circuits and overcurrent. From a practical point of view, RCBOs integrate both functions of MCB and of RCCB, functionally independent on the line voltage. Used for the protection against indirect or direct contact with live conductors or parts in network systems where the neutral and earth conductors are separated. They have instantaneous trip characteristics defined as follows: B-type: Instantaneous trip 3-5 times In For non-inductive or low inductive loads (heating resistors, generators, very long wire lines) C-type: Instantaneous trip 5-10 times In For inductive loads (mixed loads, resistive and inductive with low inrush current) Specifications Rated voltage: 230V AC Rated current: 6-40A Rated frequency: 50/60Hz Rated short circuit capacity: 6kA Rated residual current: 30mA (10mA and 300mA optional) Tripping characteristics: B and C Terminals: 1-25mm 2, max. 3 Nm Module width: 36mm Electrical life: 2,000 operations Mechanical life: 4,000 operations Operating Temp.: -25 to +55 C For detailed tripping curves see the information on our web site Compliance and standards Certifications obtained: CE, VDE, KEMA, SAA Certificate No. SAA EA Compliant with standards: IEC 61009, AS/NZS :2011 PAGE 2-33

35 Residual Current Circuit Breakers with Overcurrent Protection KZS-4M RCBO 6KA 3 pole +N Trip characteristics C curve (B curve optional) Rated residual current 30mA (10mA and 300mA optional) Type A (sinusoidal AC and pulsating DC) IEC rated current In 6 to 32A 72mm wide module Fixing on 35mm DIN rail (IEC/EN 60715) KZS-4M 3 pole +N C curve 30mA Type A Order Code Curve IEC In IEC Icn No. of DIN modules Weight Type (A) (ka) (kg) ETI C ETI C ETI C ETI C ETI C ETI C ETI C General characteristics The KZS-4M residual current circuit breakers with integral over-current protection, detect and trip in the event of residual current and protect circuits in the case of short circuits and overcurrent. From a practical point of view, RCBOs integrate both functions of MCB and of RCCB, functionally independent on the line voltage. Used for the protection against indirect or direct contact with live conductors or parts in network systems where the neutral and earth conductors are separated. They have instantaneous trip characteristics defined as follows: B-type: Instantaneous trip 3-5 times In For non-inductive or low inductive loads (heating resistors, generators, very long wire lines) C-type: Instantaneous trip 5-10 times In For inductive loads (mixed loads, resistive and inductive with low inrush current) Specifications Rated voltage: 415V AC Rated current: 6-32A Rated frequency: 50/60Hz Rated short circuit capacity: 6kA Rated residual current: 30mA (10mA and 300mA optional) Tripping characteristics: B and C Terminals: 25/35mm 2, max. 2.4 Nm Module width: 72mm Electrical life: 2,000 operations Mechanical life: 4,000 operations Operating Temp.: -25 to +55 C For detailed tripping curves see the information on our web site Compliance and standards Certifications obtained: CE, VDE, KEMA, SAA Certificate No. SAA EA Compliant with standards: IEC 61009, AS/NZS :2011 PAGE 2-34

36 Surge Protection Devices Surge protection devices Type 1 and 2 monoblock SA1 1P A320R SA1 3N A320R Surge protection devices Type 1 and 2 with plug-in cartridge SA0 1P A320R SA0 2P A320R Surge protection devices Type 2 with plug-in cartridge SA2 2P A320R SA2 3N A320R Order code Pole Relay Number Qty Wt arrange- output of DIN per ment modules pkg (SPDT) n [kg] MONOBLOCK VERSION. IEC impulse current Iimp (10/350µs) 25kA per pole. SA1 1P A320R 1P YES SA1 1N A320R 1P+N YES SA1 2P A320R 2P YES SA1 3P A320R 3P YES SA1 3N A320R 3P+N YES SA1 4P A320R 4P YES Characteristics Type IEC rated IEC voltage pro- Power voltage Un tection level Up installation [V] [kv] L-N system SA1 1P A320R 230 <1.3 TN-C, TN-S, TT SA1 1N A320R 230 <1.4 TT, TN-S SA1 2P A320R 230 <1.4 TN-S SA1 3P A320R 230/400 <1.4 TN-C SA1 3N A320R 230/400 <1.4 TT, TN-S SA1 4P A320R 230/400 <1.4 TN-S For L-PE only. Order code Pole Relay Number Qty Wt arrange- output of DIN per ment modules pkg (SPDT) n [kg] VERSION WITH PLUG-IN CARTRIDGE. IEC impulse current Iimp (10/350µs) 12.5kA per pole. SA0 1P A320R 1P YES SA0 1N A320R 1P+N YES SA0 2P A320R 2P YES SA0 3P A320R 3P YES SA0 3N A320R 3P+N YES SA0 4P A320R 4P YES Order code Pole Relay Number Qty Wt arrange- output of DIN per ment modules pkg (SPDT) n [kg] VERSION WITH PLUG-IN CARTRIDGE. IEC maximum discharge current Imax (8/20µs) 40kA per pole. SA2 1P A320 1P NO SA2 1P A320R 1P YES SA2 1N A320 1P+N NO SA2 1N A320R 1P+N YES SA2 2P A320 2P NO SA2 2P A320R 2P YES SA2 3P A320 3P NO SA2 3P A320R 3P YES SA2 3N A320 3P+N NO SA2 3N A320R 3P+N YES SA2 4P A320 4P NO SA2 4P A320R 4P YES Main characteristics The surge protection device type SA1 combines the performance of SPD type 1 and 2 into a single product. It protects against direct and indirect lightning strikes as well as induced overvoltage conditions. It can be installed in areas with a high risk of direct lightning strikes, inside main distribution boards or nearby sub-distribution boards. Operational characterstics IEC maximum continuous operating voltage Uc: 320VAC/420VDC IEC maximum discharge current Imax (8/20µs): 100kA per pole IEC rated discharge current In (8/20µs): 25kA per pole Version with relay output having changeover contact for remote status indication IEC degree of protection: IP20. Reference standards Comply with standards: IEC , EN Main characteristics SURGE PROTECTION DEVICES TYPE SA0 It has a plug-in cartridge and combines the performance of SPD type 1 and 2 into a single product. It is ideal in all those systems of reduced extent to protect the load side downstream of main circuit breaker to terminal equipment. It protects against direct and indirect lightning strikes as well as induced overvoltage conditions. It can be installed inside main distribution boards and nearby terminal equipment. The protection cartridges are plug-in and can be easily replaced for quick servicing. SURGE PROTECTION DEVICE SA2 It is suitable for installation in sub-distribution boards and nearby terminal equipment. It protects against indirect overvoltages. The protection cartridges are plug-in and can be easily replaced for quick servicing. Operational characteristics IEC maximum continuous operating voltage Uc: 320VAC/420VDC IEC maximum discharge current Imax (8/20µs) per pole: 60kA (SA0...); 40kA (SA2...) IEC rated discharge current In (8/20µs) per pole: 25kA (SA0...); 20kA (SA2...) Versions with or without relay output having changeover contact for remote status indication IEC degree of protection: IP20. Reference standards Comply with standards: IEC/EN Characteristics Type IEC rated IEC voltage Power voltage protection installation Un level Up Un Up [V] [kv] L-N SA0/SA2 1P A <1.5 TN-C, TN-S, TT SA0/SA2 1N A <1.5 TT, TN-S SA0/SA2 2P A <1.5 TN-S SA0/SA2 3P A /400 <1.5 TN-C SA0/SA2 3N A /400 <1.5 TT, TN-S SA0/SA2 4P A /400 <1.5 TN-S For L-PE only. PAGE 2-35

37 Surge Protection Devices Surge protection devices Type 2 for photovoltaic applications with plug-in cartridge SA2 DG... Order code Pole Relay Number Qty Wt arrange- output of DIN per ment modules pkg (SPDT) n [kg] VERSION WITH PLUG-IN CARTRIDGE. EN short-circuit current rating Iscpv 100A. SA2 DG 600M2 +, -, PE NO SA2 DG 600M2R +, -, PE YES SA2 DG K00M3 +, -, PE NO SA2 DG K00M3R +, -, PE YES EN short-circuit current rating Iscpv 1000A. SA2 DF 600M2 +, -, PE NO SA2 DF 600M3 +, -, PE NO SA2 DF K00M2 +, -, PE NO SA2 DF K00M3 +, -, PE NO SA2 DF K20M3 +, -, PE NO Main characteristics The surge protection device type SA2 D with plug-in cartridge for photovoltaic applications is suitable for installation on the direct-current end of a photovoltaic installation and protects against induced overvoltage conditions. The protection cartridges are plug-in and can be easily replaced for quick servicing. Operational characteristics EN maximum continuous voltage Ucpv: 600VDC, 1000VDC, 1200VDC Versions with or without relay output having changeover contact for remote status indication EN degree of protection: IP20. Certifications and compliance Certifications obtained: UL Recognised for USA and Canada (curus File E352471), as Surge-protective Devices Component, Type 4 for use in SPD Type 2 photovoltaic applications only; for SA2DF600M2, SA2DFK00M2 and SA2DFK20M3 types. Products having this type of marking are intended for use as components of complete workshop-assembled equipment. Compliant with standards: EN for all; also UL 1449 and CSA C22.2 n 8 for curus certified types mentioned above. SA2 DF... Protection circuit for each module type SA2 DF Self-protected surge protection devices Current Limiter MOV GDT T/o relay In case of short but intense overvoltage conditions, both the spark gap element (GDT- Gas Discharge Tube) and the varistor (MOV Metal Oxide Varistor) simultaneously trigger. In case of weak but prolonged overvoltage conditions, the current limiter considerably reduces the current flowing through the varistor. This technological solution guarantees a longer varistor life. Ultimately, another particular mechanism of the surge arrester quickly extinguishes the electric arc during the thermal overload tripping phase. Characteristics Type EN EN EN voltage rated continuous protection voltage voltage level Un Ucpv Up [VDC] [kv] L-N [kv] SA2 DG 600M <1.9 SA2 DG K00M <3.6 SA2 DF 600M <2.0 SA2 DF 600M <3 SA2 DF K00M <4.0 SA2 DF K00M <4.0 SA2 DF K20M <4.0 Accessories and spare parts Plug-in cartridges SAX00 P A320 Order code Description Qty Wt per pkg n [kg] SAX00 P A320 For SA0... types SAX02 P A320 For SA2... types SAX02 DF 600M2 For SA2 DF 600M2 type SAX02 DF 600M3 For SA2 DF 600M3 type SAX02 DF K00M2 For SA2 DF K00M2 type SAX02 DF K00M3 For SA2 DF K00M3 type SAX02 DF K20M3 For SA2 DF K20M3 type SAX02 DG 600M2 For SA2 DG types SAX02 DG K00M3 For SA2 DG K00... types Reference standards Compliant with standards: IEC/EN for all; EN for types SAX02 DF... and SAX02 DG...; UL 1449, CSA C22.2 n 8 for SAX02 DF 600M2, SAX02 DF K00M2, SAX02 DF K20M3. SAX02 P A320 PAGE 2-36

Motor protection circuit breakers

Motor protection circuit breakers Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

Datasheet - SRB 301LC/B-24V

Datasheet - SRB 301LC/B-24V 27.01.2016-00:27:16h Datasheet - SRB 301LC/B-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301LC/B Fit

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

Datasheet SRB301ST 24V (V.2)

Datasheet SRB301ST 24V (V.2) 26.10.2016 05:03:31h Datasheet SRB301ST 24V (V.2) Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301ST Suitable

More information

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit

More information

CS8 Industrial Control Relays

CS8 Industrial Control Relays CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum

More information

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

TeSys contactors From 115 to 2750 A

TeSys contactors From 115 to 2750 A Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

Datasheet - SRB 402EM-24V

Datasheet - SRB 402EM-24V Print - Create PDF - Create EXCEL file 20.04.2011-18:31:35h Datasheet - SRB 402EM-24V Output expanders / SRB 402EM Expander module for contact expansion 4 safety contacts, STOP 0 2 Signalling outputs (Minor

More information

Push buttons and selectors

Push buttons and selectors Accessories and spare parts 8 LM2T A130 8 LM2T A140 8 LM2T A185 8 LM2T AL... Order code Description Qty per Wt 8 LM2T A12❶ Coloured diffuser for 10 0.001 double touch buttons 8 LM2T A130 Threaded plug

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................

More information

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary

More information

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit Safety module CS DM-01 Technical data Housing PA 6.6 polyamide housing, self-extinguishing, V0 acc. to UL 94 Protection degree IP40 (housing), IP20 (terminal strip) Dimensions see page 283, design A Two-hand

More information

Page 5-3. Page 5-2 Page 5-3

Page 5-3. Page 5-2 Page 5-3 Page -2 Page -3 Page -3 ADXC Two phase control IEC rated starter current Ie 12 to 4A IEC rated motor power.-22kw at 400VAC and 9-37kW at 600VAC UL/CSA ratings 3 to 2HP at 400VAC and 10 to 40HP at 600VAC

More information

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 MKING MODERN LIVING POSSIBLE Technical brochure CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit- and overload protection of motor applications

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

Supplementary Circuit Protectors Type GSB63

Supplementary Circuit Protectors Type GSB63 Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n Safety module CS AT 0 Module for emergency stops, end position monitoring for movable guards with delayed contacts at the opening of the input channels, semiconductor outputs (e.g. light barriers and magnetic

More information

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu) DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables

More information

SWITCH DISCONNECTORS 11

SWITCH DISCONNECTORS 11 SWITCH DISCONNECTORS 16A to 1600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 850A 1000VDC in DC21B duty

More information

SIRCO Load break switches for power distribution from 125 to 5000 A

SIRCO Load break switches for power distribution from 125 to 5000 A The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un): Safety module CS AR-91, according to EN 81 Safety modules for the lift automatic floor levelling operation according to EN 81 Main functions For safety applications up to SIL 3 / PL e Choice between automatic

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................

More information

Allen-Bradley Bulletin 100 Contactors

Allen-Bradley Bulletin 100 Contactors Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression

More information

RW-E. Overloads. Solid-State Overload Relays. Standard Features

RW-E. Overloads. Solid-State Overload Relays. Standard Features RW-E The new RW_E Solid State Overload relays are developed with cutting edge technology according to the most demanding standards worldwide. With its wide current/mp setting; the RW_E OL Relay can be

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW) Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW) Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

E1 Plus Electronic Overload Relay

E1 Plus Electronic Overload Relay ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION E1 Plus NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific installations

More information

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers .2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................

More information

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities. KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA

More information

Square D General Purpose Relays

Square D General Purpose Relays Square D General Purpose Relays Class 850R miniature control relays 850RS4 standard 850RS24 low level 850RS34 hermetically sealed Catalog 204 Contents Class 850R miniature control relays bbspecifications....................................................

More information

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

UL 489 Cable-In / Cable-Out Branch Circuit Breaker Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor

More information

WEG Contactors - CWM and CWME Series

WEG Contactors - CWM and CWME Series Inside (877) 789 Fax () 87 WEG Contactors CWM and CWME Series International () 07 The CWM generalpurpose contactor line has been designed taking into consideration industrial duty and reliability in mind.

More information

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

3RV1 Circuit-Breakers

3RV1 Circuit-Breakers SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a

More information

100% electricity. Automatic transfer switch controllers ATL series

100% electricity. Automatic transfer switch controllers ATL series 100% electricity Automatic transfer switch controllers ATL series Automatic transfer switch controllers Keep control around the clock General characteristics Rated auxiliary power supply: 220-230-240VAC

More information

Max. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2

Max. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2 Bulletin T Product Selection Thermal Overload Relays For Use With C C Setting Range [A] gl/gg Max. Backup fuse [A] UL Class K ka, V AC ka, V AC IEC/EN Coordination Type Type UL.. TAA.. TAA.. TAA.. TAA..

More information

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A

More information

Allen-Bradley 1492-RCDA4A40

Allen-Bradley 1492-RCDA4A40 Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps

More information

K-Line Mini - Contactors, Overload Relays and Accessories

K-Line Mini - Contactors, Overload Relays and Accessories K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information...............................................

More information

Motor protection circuit breakers

Motor protection circuit breakers R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,

More information

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary Characteristics voltage control relay RM35-U - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts Data sheet Electronic timer CT-SDD. Star-delta change-over with n/o contacts The CT-SDD. is an electronic time relay with star-delta change-over. It is from the CT-D range. With their MDRC profile and

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that representative samples of Motor Controllers, Magnetic (See following pages for additional

More information

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure MKING MODERN LIVING POSSIBLE CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M - 100 Technical brochure 2 IC.PD.C00.5.02-520B3595 Danfoss /S (R-MC/mr) 08-2009 Contents Page Circuit Breakers/

More information

RB60 RANGE. Miniature circuit breakers

RB60 RANGE. Miniature circuit breakers RB60 RANGE Miniature circuit breakers POWER 2015 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection

More information

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70. Characteristics voltage control relay RM17-U - range 9..15 V DC Price* : 70.64 GBP Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters

More information

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary Characteristics voltage control relay RM17-U - range 183..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay

More information

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW) Characteristics soft starter-ats22-control 220V-power 230V(15kW)/400...440V(30kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths DATASHEET - ESR5-NO-41-24VAC-DC Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths Part no. ESR5-NO-41-24VAC-DC Catalog No. 118701 EL-Nummer (Norway) 0004133317 Delivery program Product

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 10 11 18 19 0 04 05 Ø 8 mm Ø 1,7 mm external rubber stainless steel stainless steel glass fibre rod gasket sphere sphere 31 51 5 57 35 56 41 4 adjustable

More information

Safety switches for hinged doors

Safety switches for hinged doors C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO Characteristics Environment Conforming to standards IEC/EN 0947-1, 0947-5-1, NF C 3-140, VDE 00 Approvals UL, CSA, DEMKO, NEMKO, SEMKO Vertical axis Horizontal axis Operating position 180 Without derating

More information

194E FA 32 E P11 P11 6

194E FA 32 E P11 P11 6 Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure

More information

ic60n RCBO 30 ma IEC , IEC , AS/NZS

ic60n RCBO 30 ma IEC , IEC , AS/NZS ic60n RCBO 30 ma DB405571 Country approval pictograms IEC 61009-1, IEC 61009-2-2, AS/NZS 61009.1 PB110075-70 b The single-phase ic60n RCBO s self-contained residual current device provides protection of

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI otor Controllers AC Semiconductor otor Controller Type RSHR IDI Soft starting and stopping of 3-phase induction squirrel cage motors 2-phase control with integral bypassing of semiconductors Low inrush

More information

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a otor Controllers AC Semiconductor otor Controller Type RSHR 3-Phase Soft starting and stopping of 3-phase squirrel cage motors Control of all 3 phases In Line or In Delta motor connection Low inrush and

More information

Program B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320

Program B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320 Push Buttons Index Page Program B3 318 Ø 22,5mm Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320 Rotary Knobs and Swing Knobs 321 Illuminated Rotary Knobs and Swing Knobs 321

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 11 18 19 0 04 05 Ø 8 mm Ø 1, mm external rubber stainless steel stainless steel glass fibre rod gasket sphere sphere 51 5 5 5 56 41 4 adjustable lever

More information

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

K1D004ACH cam switch - 4-pole A - for Ø 22 mm Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam

More information

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches

More information

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery

More information

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:

More information

Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC

Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC 100% ity Automatic power factor regulators DCRK Digital programming 5 or 7 step configuration in 96x96mm housing 8 or 12 step configuration

More information

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options otor Controllers AC Semiconductor otor Controller Type RSHR 3-Phase Soft starting and stopping of 3-phase squirrel cage motors Control of all 3 phases In Line or In Delta motor connection Low inrush and

More information

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) 9 A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 90

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information