32MP Gateway. Overview and Configuration Manual

Size: px
Start display at page:

Download "32MP Gateway. Overview and Configuration Manual"

Transcription

1 32MP Gateway Overview and Configuration Manual

2 32MP Gateway Overview and Configuration Manual

3 This document is the property of Carrier Corporation and is delivered on the express condition that it is not to be disclosed, reproduced in whole or in part, or used for manufacture by anyone other than Carrier Corporation without its written consent, and that no right is granted to disclose or so use any information contained in said document. Carrier reserves the right to change or modify the information or product described without prior notice and without incurring any liability. 1993, Carrier Corporation

4 Manual Revisions The 32MP Gateway Overview and Configuration Manual is catalog number Rev. 11/93. This manual replaces the 32MP Gateway Overview and Configuration Manual ( ) 9/92. The following changes were made since the last revision. Section/Chapter Overview Changes On Pages 5 and 10 under the topics BEST Program Access, added the following: BEST IV can write data to only those points that are accessible to the Data Tranfer function. To see the list of point names that Data Transfer can access, refer to Table 1 on Page 9. Configuration 1. Modified the last paragraph on Page 11 of the Points Screen section to read: The commands can come from an operator, or from other devices on the CCN, such as the CHILLERVISOR System Manager, Data Transfer, or BEST IV. 2. In the Points Screen section, stated that the following points could be used in conjunction with BEST IV: Chiller Start/Stop LCW Control Point Demand Limit Compressor Ontime Remote Contacts Input Spare Sensor 2, Spare Sensor 3, Spare Sensor 4 BEST Program Access In the General Information section, deleted the following sentence from the first paragraph: BEST cannot write to data in the Gateway. iii

5 iv

6 Contents Overview... 1 About this Manual... 1 Introduction MP Gateway Hardware MP Gateway Functions... 4 Program Enable/Disable... 4 Elapsed On-time Tracking... 4 Remote Contact Start/Stop... 4 Shutdown and Communication Alarms... 5 BEST Program Access... 5 CHILLERVISOR System Manager Support... 5 Operator Interface... 5 Network Functions... 8 Data Collection... 8 Data Transfer... 8 BEST Program Access... 9 Configuration General Information Points Screen Service Configuration Screen Configuration Screen Maintenance Screen Alarm Configuration Screen BEST Program Access General Information v

7 Configuration Sheets Tables Table 1 Point Names and Types for Data Collection and Transfer... 9 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Points Screen (Single Compressor) Points Screen (Dual Compressor) Service Configuration Screen (Single Compressor) Service Configuration Screen (Dual Compressor) Configuration Screen (Single Compressor) Configuration Screen (Dual Compressor) Maintenance Screen (Single Compressor) Maintenance Screen (Dual Compressor) Figures Figure 1 32MP Gateway... 3 Figure 2 32MP Gateway Points Screen (Single Compressor) Figure 3 Figure 4 Figure 5 32MP Gateway Points Screen (Dual Compressor) MP Gateway Service Configuration Screen (Single Compressor) MP Gateway Service Configuration Screen (Dual Compressor) vi

8 Figure 6 Figure 7 Figure 8 Figure 9 32MP Gateway Configuration Screen (Single Compressor) MP Gateway Configuration Screen (Dual Compressor) MP Gateway Maintenance Screen (Single Compressor) MP Gateway Maintenance Screen (Dual Compressor) Figure 10 Alarm Configuration Screen vii

9 viii

10 Overview

11 Overview About this Manual The purpose of this manual is to provide information on the 32MP Gateway s hardware, functions, and configuration. This manual is divided into four sections. The Overview section gives a detailed description of the 32MP Gateway hardware and functions. The Configuration section presents 32MP Gateway screens as they are displayed at the Building Supervisor and gives specific information about each item on the screen. This section provides a crossreference between Building Supervisor displays and the 3200MP Controller information contained in the following start-up, operation and maintenance instructions available through Carrier Literature Distribution: 19DK ( ) 19DM ( ) 19DR with DM Compressor ( ) 19DR with DK Compressor ( ) 19EB ( ) 17DK ( ) 17DM ( ) 17DR with DM Compressor ( ) 17DR with DK Compressor ( ) 3200MP Controller Retrofit ( ) 3200MP Expanded Services Panel II Start-up, Operation and Maintenance Instructions ( ) also applies to the listed equipment. The BEST Program Access section provides a list of table, point, and decision numbers that can be used in BEST programs. The Configuration Sheets section provides a copy of the 32MP configuration sheets. 1

12 Introduction The 32MP Gateway is a component of the Carrier Comfort Network (CCN) CHILLERVISOR system. The 32MP Gateway integrates a centrifugal chiller into the Carrier Comfort Network (CCN). The chiller must be equipped with a 3200MP Controller and an ESP-II Expanded Services Panel. The 32MP Gateway can be used with both single and dual compressor chillers. A single 32MP Gateway provides interface functions for one chiller. A CCN Building Supervisor communicating through a 32MP Gateway can be used to configure certain ESP-II and 3200MP Controller parameters, and to display current operating conditions of the chiller connected to them. The Building Supervisor also annunciates alarms and displays alarm messages generated by the 32MP Gateway. BEST, Carrier s custom programming language, can access points and decisions in a 32MP Gateway. BEST programs, which reside in a FID, can read data from 32MP Gateway parameters displayed on the points, service configuration, configuration, and maintenance screens. 32MP Gateway Hardware The 32MP Gateway is a CCN CIO (Communications Input/Output) Module equipped with specialized software that enables it to perform its interface functions. The 32MP Gateway is shown in Figure 1. COMM1 is the 32MP Gateway s connection to the CCN Communication Bus. The bus can operate at 1200, 2400, 4800, or 9600 bits per second (bps). It typically operates at 9600 bps. A 32MP Gateway can reside on any CCN Communication Bus, 0-239, and can be assigned any system element number, The 32MP Gateway s default address is Bus 0, System Element 85. COMM2 is the Gateway s connection to the 3200MP Controller Communication Bus. The 3200MP Controller Communication Bus operates at 1200 bps. For this reason, COMM2 also operates at 1200 bps. 2

13 The Network Configuration Tool (NCT) may be used to change the 32MP Gateway s bus and system element numbers and the baud rate of COMM1 if necessary. Figure 1 32MP Gateway 3

14 32MP Gateway Functions The 32MP Gateway s primary function is to integrate a centrifugal chiller equipped with a 3200MP Controller and an ESP-II panel into the Carrier Comfort Network II. Other 32MP Gateway functions include: Program enable/disable Elapsed on-time tracking Remote Contacts Start/Stop Shutdown and communication alarms BEST program access CHILLERVISOR System Manager (CSM) support Each function is described in detail below. Program Enable/ Disable On initial power up, the 32MP Gateway automatically determines whether it is connected to a single or dual compressor chiller. Because of this, a Building Supervisor cannot display 32MP Gateway data if the gateway is not connected to a functional 3200MP Controller Communication Bus. Two switches on the 3200MP Controller allow the user to enable and disable the 32MP Gateway manually. The two switches are the Local/Remote switch on the 3200MP s Setpoint/Display Board, and the Panel/Remote switch on the ESP-II panel. The 32MP Gateway s ability to write to the 3200MP/ESP-II software is disabled when either switch is not in the Remote position. If the switches are in the Local or Panel modes, chiller parameters can be displayed, but configuration changes cannot be made. Elapsed On-time Tracking Remote Contact Start/Stop The 32MP Gateway accumulates up to 32,767 hours of elapsed ontime for its chiller. The accumulated on-time value is displayed on the Building Supervisor s points screen, and may be modified by an operator using the Building Supervisor. The 32MP Gateway and the ESP-II panel each include a remote contact option that, when enabled, allows the chiller to be stopped and started by contact closure input from a field-installed remote start relay. Because the gateway supercedes the ESP-II panel in initiating the chiller's starts and stops, it automatically disables the panel's remote contacts option. The panel's option can be enabled, 4

15 but it will be disabled by the gateway as soon as the panel is returned to remote mode. Because of this, when enabling, disabling, or checking the status of the remote contact option the user should do so at the 32MP Gateway, not at the ESP-II panel. Shutdown and Communication Alarms BEST Program Access CHILLERVISOR System Manager Support The 32MP Gateway generates two types of alarms. A CHILFAIL alarm is generated if a 3200MP Controller shutdown fault occurs. The 3200MP status code is included in this alarm message. A CHILCOMM communication error alarm is generated in the event of a communication failure between the 32MP Gateway and the 3200MP Controller/ESP-II. If the communication failure is with the 3200MP within the chiller or with the cable from the chiller to the 32MP Gateway, a code value of 1 is included with this alarm message. If the communication failure is with the ESP-II within the chiller, a code value of 2 is included with this alarm message. When alarms occur, they are annunciated at the Building Supervisor and the alarm messages are placed into its alarm file. BEST programs, which reside in a FID, can access 32MP Gateway points and decisions. BEST can read data from 32MP Gateway parameters displayed on the points, service configuration, configuration, and maintenance screens through the appropriate tables. BEST IV can write data only to those points that are accessible by the Data Transfer function. To see the list of point names that are accessible by Data Transfer, refer to Table #1 on Page 9. The CHILLERVISOR System Manager (CSM) is a device that coordinates chillers equipped with 32MP Gateways. It can coordinate the operation of up to eight centrifugal chillers. The 32MP Gateway contains a dedicated internal data structure that can be accessed by the CSM. For specific information regarding the CSM, refer to the CSM Overview and Configuration Manual ( ). Operator Interface The Building Supervisor is the primary operator interface to the 32MP Gateway. Once a 32MP Gateway is connected to a 3200MP Controller Communication Bus and a CCN Communication Bus, an operator at a Building Supervisor can add it to the Carrier Controls List and upload the data from the 32MP Gateway to the Building Supervisor s database. 5

16 An operator working at a Building Supervisor can then: display a list of 32MP Gateway points that shows current conditions at the chiller and the last five shutdown codes. modify selected points and return them to local control. display configuration and maintenance screens and change 3200MP Controller configuration data. create graphics. There are eight screens associated with the 32MP Gateway: Points screen Service configuration screen Configuration screen (CONFIG1) Maintenance screen Alarm configuration screen (ALRM-CFG) Runtime Equipment Part Configuration screen (RUN-POC1) Consumable Equipment Part Configuration screen (CONS- POC1) Controller Identification screen (CTLR-ID) The Points screen displays the current status of chiller parameters such as status codes, setpoints, and operating temperatures. The status of selected points can be modified by the operator using the Building Supervisor s Force function. The force can be removed using the Auto function. Note that the Auto function removes only the SUPVSR force message from the Building Supervisor screen. The value entered remains in effect at the 3200MP/ ESP-II. From the Points screen, an operator can modify the values of the following points: Chiller Start/Stop Leaving Chilled Water (LCW) Control Point Demand Limit Compressor On-time Remote Contact Input 6

17 Note: Due to the nature of communications between the 32MP Gateway and the 3200MP Controller/ESP-II combination, it can take up to thirty seconds for the modified value to be displayed on the Building Supervisor screen. The Service configuration screen displays service parameters read by the 32MP Gateway from the configuration (DIP) switches located on the 3200MP Controller. Service parameters include machine, starter, and sensor types. The Configuration screen allows an operator to enter data used by the 3200MP s reset, restart, and remote contacts options. The table named CONFIG1 is selected to display this screen. The Maintenance screen displays the current status of the 3200MP Controller s inputs and outputs. The Alarm configuration screen is displayed by selecting the table named ALRM-CFG. This screen is a listing of 32MP Gateway alarm configuration decisions such as Alarm System Name and Re- Alarm Time. Specific information on each item displayed on the Points, Service Configuration, Configuration, Maintenance, and Alarm Configuration screens is provided in the Configuration section beginning on Page 11. The Runtime and Consumable Equipment Part Configuration screens are displayed by selecting the tables named RUN-POC1 and CONS-POC1. If 32MP Gateway points are to be used in conjunction with the Runtime and Consumable supervisory parts of a CCN Data Collection Option, this is where the point names and types of those points are entered. See Page 8 for more information on Data Collection. The Controller Identification screen lists 32MP Gateway controller parameters such as device name, description and location, and software and assembly part numbers. The table named CTLR-ID is selected to display this screen. 7

18 The 32MP Gateway can display units in either imperial or metric format when used with the Building Supervisor III. Data from gateways used with the Building Supervisor II can be displayed in imperial units only. Network Functions Data Collection The CCN network functions that are relevant to a 32MP Gateway are the Data Collection and Data Transfer Options, and BEST programs. The CCN Data Collection Option can be used to collect data from the 32MP Gateway points listed in Table 1. Points must be specified by name and type when configuring the Data Collection Option s supervisory part. Consumable and Runtime point names and types must also be configured in the 32MP Gateway s equipment parts (CONS-POC1 and RUN-POC1). For more information on the Data Collection Option, refer to the Data Collection Option Overview and Configuration Manual ( ). Consumable and Runtime equipment part configuration sheets can also be found in that manual. Data Transfer The CCN Data Transfer Option can be used to transfer data from or to the 32MP Gateway points listed in Table 1. To transfer data from the 32MP Gateway, the point names given in Table 1 must be configured in the Source Variable Name decisions at the Data Transfer Option. These point names must also be used when transferring data to the Gateway. A data transfer to a point results in a controller force on that point. For this reason, it is recommended that caution be used when transferring data to the 32MP Gateway. Data should not be transferred to the spare sensor points. For more information on the Data Collection Option, refer to the Data Transfer Option Overview and Configuration Manual ( ). 8

19 Table 1 Point Names and Types for Data Collection and Transfer Description Type Point Name Point Chiller Start/Stop CHIL_S_S Discrete LCW Control Point LCW_STPT Analog Demand Limit DEM_LIM Analog Compressor Ontime ONTIME Analog Remote Contacts Input REM_CON Discrete Spare Sensor 2 SPARE2 Analog Spare Sensor 3 SPARE3 Analog Spare Sensor 4 SPARE4 Analog BEST Program Access BEST programs, which reside in a FID, can access 32MP Gateway points and decisions. BEST can read data from 32MP Gateway parameters displayed on the points, service configuration, configuration, and maintenance screens. Each item displayed is indexed by a table number corresponding to the screen on which it appears, and by point or decision number. Section 3 of this manual contains a complete list of table, point, and decision numbers. Note: With the exception of the points listed in Table 1 above, the points listed in Section 3 can only be accessed by table and index number. In BEST programs the CONNECT statement is used to access 32MP Gateway parameters. Use the following format to read any 32MP Gateway point or decision: CONNECT var AS A DECISION TO table, index IN number where var is a user-defined name for the point or decision. table is a number corresponding to the 32MP Gateway screen on which the point or decision appears. index is a number corresponding to the 32MP Gateway point or decision. 9

20 number is a 32MP Gateway s system element number on a CCN Communication Bus. BEST IV can write data to only those points that are accessible to the Data Transfer function. To see the list of point names that Data Transfer can access, refer to Table 1 on Page 9. When using BEST IV to write to points, use this statement format to connect to variables: CONNECT var AS A type TO point IN element USING SAFETY LIMITS low, high Note: The format shown above can only be used for the points listed in Table 1. All other points must use the format shown on the previous page. Remember that the other points can only be read by BEST, not written to by BEST. For more information on BEST, refer to the CCN BEST IV Programmer's Reference Manual ( ). 10

21 Configuration

22 Configuration General Information This section shows single and dual compressor 32MP Gateway screens displayed at the Building Supervisor. Specific information regarding individual parameters is given following each screen. Wherever possible, this section provides cross-reference to related Carrier documentation: 3200MP Controller Retrofit Startup, Operation, and Maintenance Manual 3200MP Expanded Services Panel Start-up, Operation and Maintenance Instructions 17-series and 19-series Startup, Operation and Maintenance Manuals Title and catalog numbers for these documents are listed on Page 1 of this manual. Points Screen The Points menu item is used to select the Points screen. The Points screen displays current conditions at the chiller and the last five shutdown codes. The Building Supervisor or Service Tool s force operation can be used to modify the values of selected 32MP Gateway points. Transmitting a force command to one of these points causes its value to change and the SUPVSR force message to be displayed on screen with the point. Using the Auto operation removes the SUPVSR force message from the screen. The point does not return to the value it had before being forced. Of the 32MP Gateway points that can be modified, only Compressor On-time displays a dynamic value. The other modifiable points only change their values when commanded to. The commands can come from an operator, or from other devices on the CCN, such as CHILLERVISOR System Manager, Data Transfer, or BEST IV. 11

23 12 Figure 2 32MP Gateway Points Screen (Single Compressor)

24 Figure 3 32MP Gateway Points Screen (Dual Compressor) 13

25 The points screen for a 32MP Gateway installed on a single compressor chiller is shown in Figure 2. The points screen for a 32MP Gateway installed on a dual compressor chiller is shown in Figure 3. Specific point information follows. Chiller Status Code Lead Compressor Status Code Lag Compressor Status Code Maintenance Manual: Diagnostic Codes These points display current status code numbers. The Chiller Status Code point appears on the single compressor points screen only. The Lead and Lag Compressor Status Code points appear on the dual compressor points screen only. Note: When the operator uses the ESP panel to place a chiller in its local test mode, a status code of 164 appears on the Building Supervisor screen. The ESP panel screen, however, displays the test mode information. Display Units Diagnostic code numbers Chiller Start/Stop The function of this point is analogous to that of the manual start/stop switch located on the 3200MP Controller s Setpoint/Display panel. This allows an operator (or external software such as the CSM or writing to this variable with the Data Transfer Option) to start and stop the chiller. This point also provides an indication of the chiller s current commanded status for the operator. This point can be modified by the operator, and can be used in conjunction with the Data Collection and Data Transfer Options, and BEST IV. For information on Data Transfer, refer to the Data Transfer Option Overview and Configuration Manual ( ). The Remote Contact option is disabled when this point is forced. Display Units Stop Start 14

26 LCW Control Point Reference: 3200MP Expanded Services Panel Start-up, Operation and Maintenance Instructions: Displaying ESP Chilled Water Control Point This point displays the value of the Leaving Chilled Water Control Point currently in effect at the 3200MP Controller. This value defaults to the one entered by means of the Thermostat control on the Setpoint/Display panel, unless that value is overwritten either from the ESP-II panel or by the Chilled Water Reset option. This point can be modified by the operator, and can be used in conjunction with the Data Collection and Data Transfer Options and BEST IV. Display Units Degrees Demand Limit Reference: 3200MP Expanded Services Panel Start-up, Operation and Maintenance Instructions: Displaying Basic 3200MP Demand Limit Setpoint This decision displays the value of the Demand Limit setpoint. This value will be the same as the one entered by means of the Electrical Demand control on the 3200MP Controller s Setpoint/ Display panel, unless that value has been overwritten from the ESP-II panel. This point can be modified by the operator, and can be used in conjunction with the Data Collection and Data Transfer Options, and BEST IV. Display Units Percent kw Leaving Chilled Water Reference: 3200MP Expanded Services Panel Start-up, Operation and Maintenance Instructions: Displaying Machine Operating Parameters This is the current Leaving Chilled Water temperature. Display Units Degrees 15

27 Evaporator Refrigerant Trippoint Maintenance Manual: Safety Controls Analog Safety Control Limits; Capacity Overrides The chiller will shut down if the evaporator refrigerant temperature goes below the value displayed. This provides freeze protection for the chiller barrel. Display Units Degrees Evaporator Refrigerant Condenser Refrigerant Maintenance Manual: Safety Controls Analog Safety Control Limits; Capacity Overrides Reference: 3200MP Expanded Services Panel Start-up, Operation and Maintenance Instructions: Displaying Machine Operating Parameters These are the current evaporator and condenser refrigerant temperatures. Display Units Degrees Compressor Ontime At the time of installation the value of this point should be modified using the Building Supervisor s Force operation to correspond to the value displayed by the ontime indicator mounted on the chiller control panel. The Auto operation should then be used to remove the Force, allowing the point s value to increment. This value will increment up to 32,767 hours, then reset to 0 and continue. This point can be used in conjunction with the Data Collection and Data Transfer Options, and BEST IV. Display Units Hours 16

28 Remote Contacts Input Maintenance Manual: Remote Start/Stop Controls This decision displays the current status of the remote start contacts input. If the Remote Contacts Option is enabled on the Configuration screen and the status of this point is on, the chiller will start. When Chiller Start/Stop is forced, the Remote Contacts Option is disabled. This point can be modified by the operator, and can be used in conjunction with the Data Collection and Data Transfer Options, and BEST IV. Display Units Open = Remote start contacts open Closed = Remote start contacts closed Compressor Motor Load Compressor A Motor Load Compressor B Motor Load Maintenance Manual: Capacity Overrides The values displayed here are internally calculated values that the 3200MP Controller uses to correct differences in motor power factors at various loads. Compressor Motor Load is calculated by multiplying Compressor Motor Current by Amps Correction Factor. The Compressor Motor Load point appears on the single compressor points screen only. The Compressor A and B Motor Load points appear on the dual compressor points screen only. Display Units Percent Compressor Motor Current Compressor A Motor Current Compressor B Motor Current Reference: 3200MP Expanded Services Panel Start-up, Operation and Maintenance Instructions: Displaying Machine Operating Parameters These are compressor motor currents expressed as a percentage of RLA (Rated Load Amps). 17

29 The Compressor Motor Current point appears on the single compressor points screen only. The Compressor A and B Motor Current points appear on the dual compressor points screen only. Display Units Percent Motor Winding Motor A Winding Motor B Winding Maintenance Manual: Capacity Overrides Reference: 3200MP Expanded Services Panel Start-up, Operation and Maintenance Instructions: Displaying Machine Operating Parameters These are the current motor winding temperatures. The Motor Winding point appears on the single compressor points screen only. The Motor A and B Winding points appear on the dual compressor points screen only. Display Units Degrees Compressor Discharge Compressor A Discharge Compressor B Discharge Maintenance Manual: Analog Safety Control Limits Reference: 3200MP Expanded Services Panel Start-up, Operation and Maintenance Instructions: Displaying Machine Operating Parameters These are the current compressor discharge temperatures. The Compressor Discharge point appears on the single compressor points screen only. The Compressor A and B Discharge points appear on the dual compressor points screen only. Display Units Degrees 18

30 Thrust Bearing Thrust Bearing A Thrust Bearing B Maintenance Manual: Analog Safety Control Limits Reference: 3200MP Expanded Services Panel Start-up, Operation and Maintenance Instructions: Displaying Machine Operating Parameters These are the current thrust bearing temperatures. The Thrust Bearing point appears on the single compressor points screen only. The Thrust Bearing A and B points appear on the dual compressor points screen only. Display Units Degrees Spare Sensor 1 Maintenance Manual: Control Wiring Schematic Optional Sensor #1 Display Units Degrees Spare Sensor 2 Spare Sensor 3 Spare Sensor 4 Maintenance Manual: Control Wiring Schematic Optional Sensors #2, #3, #4 These spare points are provided as options and could be used to read any 5K thermistor sensor. Possible uses could be for condensor water or chilled water header supply and return temperatures. These points can be used in conjunction with the Data Collection and Data Transfer Options, and BEST IV. Note: Display Units Exercise care if using Data Transfer to transfer data into these points, as the Data Transfer Option only updates data once per minute. Degrees 19

31 Shutdown Code 1 Shutdown Code 2 Shutdown Code 3 Shutdown Code 4 Shutdown Code 5 Reference: 3200MP Expanded Services Panel Start-up, Operation and Maintenance Instructions: Displaying Stored Shutdown Status Codes Shutdown Code 1 shows the most recent shutdown code, Shutdown Code 2 the next most recent, Shutdown Code 3 the next, etc. The codes are explained in the 3200MP Expanded Services Panel Startup, Operation and Maintenance Instructions. Display Units Shutdown code number Control Voltage Reference: 3200MP Expanded Services Panel Start-up, Operation and Maintenance Instructions: Displaying Machine Operating Parameters This point displays the present control voltage. Display Units Volts (Vac) Starts In 6 Hours Maintenance Manual: Compressor Starts Reminder This is the number of times that the chiller has been commanded to start in the last six hours. Display Units Number of starts Compressor B Is Lead Reference: 17-series and 19-series Startup, Operation and Maintenance Manuals: Analog Expansion Board This point indicates the status of the Lead Compressor Selection switch on the Analog Expansion Board mounted inside the 3200MP Controller. This point appears on the dual compressor points screen only. Display Units No = Compressor B is lag Yes = Compressor B is lead 20

32 Remote Mode Enabled Maintenance Manual: Setpoint/Display Board This indicates the current status of the Local/Remote switch on the Setpoint/Display panel. Both the Local/Remote on the Setpoint/Display panel and the Panel/ Remote switch on the ESP-II panel must be set to the Remote position for the 32MP Gateway to process configuration changes. Display Units No = Local Yes = Remote Lag Disable Switch Set Reference: 17-series and 19-series Startup, Operation and Maintenance Manuals: Configuration (DIP) Switch Settings - Lag Compressor Enable/Disable This indicates the current position of the Lag Compressor Enable/ Disable switch, located at the 3200MP Controller. This point appears on the dual compressor points screen only. Display Units No = Lag enabled Yes = Lag disabled Service Configuration Screen The service configuration screen is selected by the operator at a Building Supervisor to display chiller service parameters, set by configuration (DIP) switches located on the 3200MP Controller s processor board. Service parameters cannot be changed from the Building Supervisor. The Service-Config menu item is used to select this screen. The service configuration screen for a 32MP Gateway installed on a single compressor chiller is shown in Figure 4. The service configuration screen for a 32MP Gateway installed on a dual compressor chiller is shown in Figure 5. Specific decision information follows. 21

33 22 Figure 4 32MP Gateway Service Configuration Screen (Single Compressor)

34 Figure 5 32MP Gateway Service Configuration Screen (Dual Compressor) 23

35 DM Compressor Maintenance Manual: Compressor Type Display Units No = not DM Yes = DM Machine Type Is CB Maintenance Manual: Machine Type This decision appears on the single compressor Service Configuration screen only. Display Units No = not CB (gear driven chiller) Yes = CB (non-gear driven chiller) Leaving Chilled Water (LCW) Deadband Maintenance Manual: LCW Deadband Display Units Degrees Leaving Chilled Water (LCW) Proportional Band Maintenance Manual: LCW Proportional Band Display Units Degrees Line Frequency Maintenance Manual: Line Frequency Display Units Hz Full Voltage Starter Type Maintenance Manual: Starter Type Display Units No = reduced voltage Yes = full voltage 24

36 Motor Sensor Type Maintenance Manual: Motor Winding Sensor Type Display Units Analog Discrete Thrust Sensor Type Maintenance Manual: Thrust Bearing Sensor Type This decision appears on the single compressor service configuration screen only. Display Units Analog Discrete Brine Medium Maintenance Manual: Chilled Medium Display Units No = Water Yes = Brine Fahrenheit Temperature Maintenance Manual: LCD Temperature Readout Display Units No = Degrees C Yes = Degrees F Chiller Controller ID Maintenance Manual: Controller Identification Number Display Units Chiller numbers 25

37 Compressor A Capacity Reference: 17-series and 19-series Startup, Operation and Maintenance Manuals: Relative Capacity of Compressor A This decision appears on the dual compressor service configuration screen only. Display Units Percent Y Degrees Selection Reference: 17-series and 19-series Startup, Operation and Maintenance Manuals: Y (degrees) This decision appears on the dual compressor service configuration screen only. Display Units Degrees X Minutes Selection Reference: 17-series and 19-series Startup, Operation and Maintenance Manuals: X (minutes) This decision appears on the dual compressor service configuration screen only. Display Units Minutes Local Ramp Rate Maintenance Manual: Ramp Loading Rate Display Units Degrees per minute Impeller Diameter Impeller Diameter A Impeller Diameter B Maintenance Manual: DM Compressor Identification Code Impeller Diameter decision is on the single compressor service configuration screen only. Impeller Diameter A and B decisions are on the dual compressor service configuration screen only. Display Units Inches 26

38 Switch Bank 3, Switch Positions: = Off Off Off Off = On Off Off Off = Off On Off Off = On On Off Off = Off Off On Off = On Off On Off = Off On On Off = On On On Off = Off Off Off On = On Off Off On = Off On Off On = On On Off On = Off Off On On = On Off On On Diffuser Width Diffuser Width A Diffuser Width B The values displayed in these decisions indicate the diffuser wall widths, in inches. The Diffuser Width decision appears on the single compressor service configuration screen only. The Diffuser Width A and B decisions appear on the dual compressor service configuration screen only. Display Units Inches 27

39 Switch Switch Function Switch Width Bank Position Settings (Inches) Diffuser Width Diffuser Width A Diffuser Width B Diffuser Width B 6 7 Off On Off On Off Off.44 On On Off On Off Off.45 Off Off On On Off Off.46 On Off On On Off Off.47 Off Off Off Off Off Off.48 Off On On On Off Off.49 On On On On Off Off.50 Off Off Off Off On Off.51 On Off Off Off On Off.52 Off On Off Off On Off.53 On On Off Off On Off.54 On Off Off Off Off Off.55 Off Off On Off On Off.56 On Off On Off On Off.57 Off On On Off On Off.58 On On On Off On Off.59 Off On Off Off Off Off.60 Off Off On Off Off Off.61 Off Off Off On On Off.62 On Off Off On On Off.63 Off On Off On On Off.64 On On Off On On Off.65 On On Off Off Off Off.66 Off Off On On On Off.67 On Off On On Off On.68 On Off On Off Off Off.69 Off On On On On Off.70 On On On On On Off.71 Off Off Off On Off Off.72 Off Off Off Off Off On.73 On Off Off Off Off On.74 (continued) 28

40 Switch Switch Function Switch Width Bank Position Settings (Inches) Diffuser Width Diffuser Width A Diffuser Width B Diffuser Width B 6 7 Off On Off Off Off On.75 Off On On Off Off Off.76 On On Off Off Off On.77 Off Off On Off Off On.78 On Off On Off Off On.79 Off On On Off Off On.80 On On On Off Off On.81 Off Off Off On Off On.82 On On On Off Off Off.83 On Off Off On Off On.84 Off On Off On Off On.85 On On Off On Off On.86 Off Off On On Off On.87 On Off On On Off On.88 Off On On On Off On.89 On On On On Off On.90 On Off Off On Off Off.91 Off Off Off Off On On.92 On Off Off Off On On.93 Off On Off Off On On.94 On On Off Off On On.95 Off Off On Off On On.96 On Off On Off On On.97 Off On On Off On On.98 On On On Off On On.99 Off Off Off On On On 1.0 On Off Off On On On 1.01 Off On Off On On On 1.02 On On Off On On On 1.03 Off Off On On On On 1.04 On Off On On On On 1.05 Off On On On On On 1.06 On On On On On On

41 Lag Shutdown Table Reference:17-series and 19-series Startup, Operation and Maintenance Manuals: Lag Turn-Off % Corrected Amps The Lag A and B Shutdown Table decisions (on the configuration screen) can be used to override the value entered at the 3200MP Controller s configuration switches. Refer to Page 38 of this manual for information regarding those decisions. This decision appears on the dual compressor service configuration screen only. Display Units 0 = Lag turn-off correction disabled 1 = Turn off lag sooner = Normal setting = Turn off lag later Amps Correction Factor Amps Correction Factor A Amps Correction Factor B Reference: 17-series and 19-series Startup, Operation and Maintenance Manuals: Compressor Motor Amps Correction Factor The Amps Correction Factor decision appears on the single compressor service configuration screen only. The Amps Correction Factor A and B decisions appear on the dual compressor service configuration screen only. Display Units 1 = Increase = Decrease 30

42 Compressor Selection Factor Reference: 17-series and 19-series Startup, Operation and Maintenance Manuals: Compressor Selection Factor Display Units Switch Bank 4, Switch Positions: = Off Off Off 2 = On Off Off 3 = Off On Off 4 = On On Off 5 = Off Off On 6 = On Off On 7 = Off On On 8 = On On On Configuration Screen The configuration screen is displayed by the operator at a Building Supervisor to configure reset and demand limit types, and chiller options. The table named CONFIG-1 is selected to display this screen. The configuration screen for a 32MP Gateway installed on a single compressor chiller is shown in Figure 6. The configuration screen for a 32MP Gateway installed on a dual compressor chiller is shown in Figure 7. Specific decision information follows. 31

43 32 Figure 6 32MP Gateway Configuration Screen (Single Compressor)

44 Figure 7 32MP Gateway Configuration Screen (Dual Compressor) 33

45 Temperature Reset Type Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Leaving Chilled Water Temperature Reset Allowable Entries 0 = chilled water reset options disabled 1 = reset based on cooler temperature difference 2 = reset based on a 4-20 ma input signal 3 = reset based on a remote temperature sensor input 4 = return chilled water temperature control Degrees Reset for Temperature 1 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Chilled Water Reset Based on Cooler Temperature Difference Reset Temperature A This decision is used when the Temperature Reset Type decision is set to 1. Allowable Entries -30 to 30 degrees F (-34 to -1 degrees C) Reset 1 Temperature 1 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Chilled Water Reset Based on Cooler Temperature Difference Delta-T for Reset Temperature A This decision is used when the Temperature Reset Type decision is set to 1. Allowable Entries 0 to 20 degrees F (-18 to -7 degrees C) 34

46 Degrees Reset for Temperature 2 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Chilled Water Reset Based on Cooler Temperature Difference Reset Temperature B This decision is used when the Temperature Reset Type decision is set to 1. Allowable Entries -30 to 30 degrees F (-34 to -1 degrees C) Reset 1 Temperature 2 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Chilled Water Reset Based on Cooler Temperature Difference Delta-T for Reset Temperature B This decision is used when the Temperature Reset Type decision is set to 1. Allowable Entries 0 to 20 degrees F (-18 to -7 degrees C) Reset 2 Degrees for ma 1 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Chilled Water Reset Based on a 4-20 ma Input Signal Reset Temperature A This decision is used when the Temperature Reset Type decision is set to 2. Allowable Entries -30 to 30 degrees F (-34 to -1 degrees C) 4-20 ma Point 1 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Chilled Water Reset Based on a 4-20 ma Input Signal Input Signal A This decision is used when the Temperature Reset Type decision is set to 2. Allowable Entries 4 to 20 ma (dc) 35

47 Reset 2 Degrees for ma 2 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Chilled Water Reset Based on a 4-20 ma Input Signal Reset Temperature B This decision is used when the Temperature Reset Type decision is set to 2. Allowable Entries -30 to 30 degrees F (-34 to -1 degrees C) 4-20 ma Point 2 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Chilled Water Reset Based on a 4-20 ma Input Signal Input Signal B This decision is used when the Temperature Reset Type decision is set to 2. Allowable Entries 4 to 20 ma (dc) Reset 3 Degrees for RT1 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Chilled Water Reset Based on a Remote Temperature Sensor Input Reset Temperature A The decision is used when the Temperature Reset Type decision is set to 3. Allowable Entries -30 to 30 degrees F (-34 to -1 degrees C) Remote Temperature Point 1 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Chilled Water Reset Based on a Remote Temperature Sensor Input Remote Temperature A This decision is used when the Temperature Reset Type decision is set to 3. Allowable Entries -20 to 240 degrees F (-29 to 116 degrees C) 36

48 Reset 3 Degrees for RT2 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Chilled Water Reset Based on a Remote Temperature Sensor Input Reset Temperature B This decision is used when the Temperature Reset Type decision is set to 3. Allowable Entries -30 to 30 degrees F (-34 to -1 degrees C) Remote Temperature Point 2 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Chilled Water Reset Based on a Remote Temperature Sensor Input Remote Temperature B This decision is used when the Temperature Reset Type decision is set to 3. Allowable Entries -20 to 240 degrees F (-29 to 116 degrees C) Reset 4 ECW Setpoint Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Return Chilled Water Temperature Control Entering Temperature Control Point This decision is used when the Temperature Reset Type decision is set to 4. Allowable Entries 0 to 120 degrees F (-18 to 49 degrees C) Demand Limit Type Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Power Demand Limit Allowable Entries 0 = demand limit options disabled 1 = demand limit based on contact closure 2 = demand limit based on a 4-20 ma input signal 37

49 Demand 1 for Contact 1 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Power Demand Limit Based on Contact Closure Switch A Demand Limit This decision is used when the Demand Limit Type decision is set to 1. Allowable Entries 40 to 100 percent Demand 1 for Contact 2 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Power Demand Limit Based on Contact Closure Switch B Demand Limit This decision is used when the Demand Limit Type decision is set to 1. Allowable Entries 40 to 100 percent Demand 1 for Contact 3 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Power Demand Limit Based on Contact Closure Switch C Demand Limit This decision is used when the Demand Limit Type decision is set to 1. Allowable Entries 40 to 100 percent Demand 2 for Milliamp 1 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Power Demand Limit Based on 4-20 ma Input Signal Demand Limit A This decision is used when the Demand Limit Type decision is set to 2. Allowable Entries 40 to 100 percent 38

50 4-20 Milliamp Point 1 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Power Demand Limit Based on 4-20 ma Input Signal Input Signal A This decision is used when the Demand Limit Type decision is set to 2. Allowable Entries 4 to 20 ma (dc) Demand 2 for Milliamp 2 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Power Demand Limit Based on 4-20 ma Input Signal Demand Limit B This decision is used when the Demand Limit Type decision is set to 2. Allowable Entries 40 to 100 percent 4-20 Milliamp Point 2 Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Power Demand Limit Based on 4-20 ma Input Signal Input Signal B This decision is used when the Demand Limit Type decision is set to 2. Allowable Entries 4 to 20 ma (dc) Automatic Restart Option Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Automatic Restart After Power Failure Allowable Entries Disable Enable Remote Contacts Option Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Remote Contact Start/Stop The 32MP Gateway and the ESP-II panel each include a remote contacts option that, when enabled, allows the chiller to be stopped 39

51 and started by contact closure input from a field-installed remote start relay. Because the gateway supercedes the ESP-II panel in initiating the chiller's starts and stops, it automatically disables the panel's remote contacts option. The panel's option can be enabled, but it will be disabled by the gateway as soon as the panel is returned to remote mode. Because of that, when enabling, disabling, or checking the status of the remote contacts option the user should do so at the 32MP Gateway, not at the ESP-II panel. Allowable Entries Disable Enable Remote Ramp Rate Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Ramp Loading Rate Adjustment Allowable Entries 0 to 8 (code numbers) Lag A Shutdown Table Lag B Shutdown Table Reference: 3200MP Expanded Services Panel Start-up, Operation, and Maintenance Instructions: Dual Compressor Chiller Lag Compressor Turn-Off Correction This decision allows the 32MP Gateway to override 3200MP Controller DIP switch settings. An entry of 0 here allows the DIP switch configuration to be used. These decisions appear on the dual compressor configuration screen only. Allowable Entries 0 = Correction override disabled (DIP switch settings enabled) 1 = Turn lag off sooner = Normal setting = Turn lag off later 40

52 Maintenance Screen The maintenance screen is displayed by the operator at a Building Supervisor to display the status of inputs and outputs wired to the 3200MP Controller and diffuser wall position (DM machines only). The Maintenance menu item is used to select this screen. The maintenance screen for a 32MP Gateway installed on a single compressor chiller is shown in Figure 8. The maintenance screen for a 32MP Gateway installed on a dual compressor chiller is shown in Figure 9. Specific decision information follows. Figure 8 32MP Gateway Maintenance Screen (Single Compressor) 41

53 42 Figure 9 32MP Gateway Maintenance Screen (Dual Compressor)

54 Oil Pressure Switch Input Maintenance Manual: Start-up Sequence Oil Pressure Switch; Control Wiring Schematic Oil Pressure Display Units Close = pressure Open = no pressure Condenser Pump Relay Output Maintenance Manual: Start-up Sequence Condenser Water Pump Relay; Control Wiring Schematic CDW Pump Start Display Units Off = de-energized On = energized Condenser Flow Switch Input Maintenance Manual: Start-up Sequence Condenser Flow Switch; Control Wiring Schematic CDW Flow Display Units Close = flow Open = no flow Tower Fan Relay Output Maintenance Manual: Start-up Sequence Tower Fan Relay; Control Wiring Schematic Tower Fan Enable Display Units Off = de-energized On = energized Purge Pump Relay Output Maintenance Manual: Excessive Purge Pump Run Time; Control Wiring Schematic Purge Pump Display Units Off = de-energized On = energized 43

55 Purge Switch Input Maintenance Manual: Excessive Purge Pump Run Time; Control Wiring Schematic Purge Display Units Close = pump on Open = pump off Alarm Relay Output Maintenance Manual: Control Wiring Schematic Alarm Display Units On = alarm limits exceeded Off = normal operation Spare Protection Limit Input Maintenance Manual: Spare Safety Inputs; Control Wiring Schematic Spare Display Units Close = normal operation Open = alarm limits exceeded Compressor 1CR Output Compressor A 1CR Output Compressor B 1CR Output Maintenance Manual: Start-up Sequence 1CR Relay; Control Wiring Schematic Compressor Start Output The Compressor Start Relay Output decision appears on the single compressor maintenance screen only. The Compressor A and B Start Relay Output Decisions appear on the dual compressor maintenance screen only. Display Units Off = de-energized On = energized 44

56 Compressor 1CR Aux Contact Compressor A 1CR Aux Contact Compressor B 1CR Aux Contact Maintenance Manual: Start-up Sequence 1CR Auxiliary Contact; Control Wiring Schematic Compressor Start Input The Compressor 1CR Start Input decision appears on the single compressor maintenance screen only. The Compressor A and B 1CR Start Input decisions appear on the dual compressor maintenance screen only. Display Units Close = not starting Open = start-up in progress Compressor Aux Run Contact Compressor A Aux Run Contact Compressor B Aux Run Contact Maintenance Manual: Control Wiring Schematic Compressor Run The Compressor 1CR Run Input decision appears on the single compressor maintenance screen only. The Compressor A and B 1CR Run Input decisions appear on the dual compressor maintenance screen only. Display Units Close = running Open = not running Compressor Start Circuit Volt Compressor A Start Circuit Volt Compressor B Start Circuit Volt Maintenance Manual: Control Wiring Schematic Compressor Run The Compressor High Pressure Input decision appears on the single compressor maintenance screen only. The Compressor A and B High Pressure Input decisions appear on the dual compressor maintenance screen only. Display Units Yes = normal operation No = alarm limits exceeded when running 45

57 Motor Temperature Switch Input Motor A Temperature Switch Input Motor B Temperature Switch Input Maintenance Manual: Control Wiring Schematic Motor (Discrete) The Compressor Winding Temperature Input decision appears on the single compressor maintenance screen only. The Compressor A and B Winding Temperature Input decisions appear on the dual compressor maintenance screen only. Display Units Close = normal operation Open = alarm limits exceeded Guide Vane Increase Guide Vane A Increase Guide Vane B Increase Maintenance Manual: Control Wiring Schematic Vane Open The Guide Vane Increase decision appears on the single compressor maintenance screen only. The Guide Vane A and B Increase decisions appear on the dual compressor maintenance screen only. Display Units Off = guide vane stationary On = guide vane opening Guide Vane Decrease Guide Vane A Decrease Guide Vane B Decrease Maintenance Manual: Control Wiring Schematic Vane Close The Guide Vane Decrease decision appears on the single compressor maintenance screen only. The Guide Vane A and B Decrease decisions appear on the dual compressor maintenance screen only. Display Units Off = guide vane stationary On = guide vane closing 46

58 Diffuser Wall Increase Diffuser Wall A Increase Diffuser Wall B Increase Maintenance Manual: Control Wiring Schematic Diffuser Wall The Diffuser Wall Increase decision appears on the single compressor maintenance screen only. The Diffuser Wall A and B Increase decisions appear on the dual compressor maintenance screen only. Display Units Off = diffuser wall stationary On = diffuser wall opening Diffuser Wall Decrease Diffuser Wall A Decrease Diffuser Wall B Decrease Maintenance Manual: Control Wiring Schematic Diffuser Wall The Diffuser Wall Decrease decision appears on the single compressor maintenance screen only. The Diffuser Wall A and B Decrease decisions appear on the dual compressor maintenance screen only. Display Units Off = diffuser wall stationary On = diffuser wall closing Impeller Displacement Input Maintenance Manual: Control Wiring Schematic Impeller Displacement This decision appears on the single compressor maintenance screen only. Display Units Close = normal operation Open = alarm limits exceeded 47

59 Figure 10 Alarm Configuration Screen Alarm Configuration Screen The alarm configuration screen is displayed by the operator at a Building Supervisor to configure alarm parameters such as system names and re-alarm times. The table named ALARM-CFG is selected to display this screen. The alarm configuration screen is shown in Figure 10. Specific decision information follows. Alarm Control This decision defines the CCN system elements that will process 32MP Gateway alarms. Allowable Entries 0 = Alarm processing disabled 64 = Autodial Gateways 128 = Local Building Supervisors 192 = Local Building Supervisors and Autodial Gateways 208 = Local Building Supervisors, Autodial Gateways, and Alarm Printer Interface Module 48

60 Alarm Equipment Priority This is used to define the priority of 32MP Gateway alarms. A priority of 0 is the highest priority and a priority of 7 is the lowest priority. A priority of 4 is reserved for chiller alarms. It is therefore recommended that you do not change the value of this decision. Allowable Entries 0 to 7 priority numbers Communication Failure Retry Time This decision defines the interval between alarm retries. If an alarm sent by the 32MP Gateway is not acknowledged by a network alarm acknowledger, the same alarm will be sent again following the amount of time entered in this decision. Allowable Entries 1 to 240 minutes Re-alarm Time This is the interval between re-alarms sent by the 32MP Gateway. As long as the alarm condition that initially caused an alarm exists, the 32MP Gateway will continue to retransmit the alarm at regular intervals. The interval between retransmissions is the amount of time entered in this decision. Re-alarming will stop when the alarm condition returns to normal. Allowable Entries 1 to 255 minutes Alarm System Name This decision is used to identify the system element generating an alarm. In the case of the 32MP Gateway, the default name 32MPGTWY will appear in the alarm message displayed at Building Supervisors. In a multiple chiller system this name can be changed to identify the gateway serving each individual chiller. 32MPGW-1 and 32MPGW-2 might be used, for example. Allowable Entries Up to 8 alphanumeric characters 49

61 50

62 BEST Program Access

63 BEST Program Access General Information BEST programs can read data from each item displayed on the 32MP Gateway s points, service configuration, configuration, and maintenance screens through the appropriate tables. This section provides a list of table, point, and decision numbers used in BEST programs. Further information regarding a BEST program s access to 32MP Gateway parameters can be found on Pages 5 and 9 of this manual. Table 2 Points Screen (Single Compressor) Description Index Range Table Number Chiller Status Code Chiller Start/Stop 2 0,1 17 LCW Control Point Demand Limit Leaving Chilled Water Evaporator Ref. Trippoint Evaporator Refrigerant Condenser Refrigerant Compressor Ontime , Remote Contacts Input 10 0,1 17 Compressor Motor Load Compressor Motor Current Motor Winding Compressor Discharge Motor Thrust Bearing Spare Sensor Spare Sensor Spare Sensor Spare Sensor Shutdown Code Shutdown Code Shutdown Code Shutdown Code Shutdown Code Control Voltage Starts in 6 Hours Remote Mode Enabled 27 0,

64 Table 3 Points Screen (Dual Compressor) Description Index Range Table Number Lead Compressor Status Code Lag Compressor Status Code Chiller Start/Stop 3 0,1 17 LCW Control Point Demand Limit Leaving Chilled Water Evaporator Ref. Trippoint Evaporator Refrigerant Condenser Refrigerant Compressor Ontime Remote Contacts Input 11 0,1 17 Compressor A Motor Load Compressor B Motor Load Compressor A Motor Current Compressor B Motor Current Motor A Winding Motor B Winding Compressor A Discharge Compressor B Discharge Thrust Bearing A Thrust Bearing B Spare Sensor Spare Sensor Spare Sensor Spare Sensor Shutdown Code Shutdown Code Shutdown Code Shutdown Code Shutdown Code Control Voltage Starts in 6 Hours Compressor B Is Lead 33 0, Remote Mode Enabled 34 0,1 17 Lag Disable Switch Set 35 0,

65 Table 4 Service Configuration Screen (Single Compressor) Description Index Range Table Number DM Compressor 1 0, Machine Type Is CB 2 0, LCW Deadband 3 1,2 19 LCW Proportional Band 4 5,15 19 Line Frequency 5 60,50 19 Full Voltage Starter Type 6 0, Motor Sensor Type 7 255,0 19 Thrust Sensor Type 8 255,0 19 Brine Medium 9 0, Fahrenheit Temperature 10 0, Chiller Controller ID Local Ramp Rate Impeller Diameter 13 0, Diffuser Width Amps Correction Factor Compressor Selection Factor

66 Table 5 Service Configuration Screen (Dual Compressor) Description Index Range Table Number DM Compressor 1 0, LCW Deadband 2 1,2 19 LCW Proportional Band 3 5,15 19 Line Frequency 4 60/50 19 Full Voltage Starter Type 5 0, Motor Sensor Type 6 255,0 19 Brine Medium 7 0, Fahrenheit Temperature 8 0, Chiller Controller ID Compressor A Capacity Y Degrees Selection X Minutes Selection Local Ramp Rate Impeller Diameter A Diffuser Width A Impeller Diameter B 16 0, Diffuser Width B Lag Shutdown Table Amps Correction Factor A Amps Correction Factor B Compressor Selection Factor

67 Table 6 Configuration Screen (Single Compressor) Description Index Range Table Number Temperature Reset Type Reset 1 Temperature Degrees Reset for Temp Reset 2 Temperature Degrees Reset for Temp Reset 2 Degrees for ma ma Point Reset 2 Degrees for ma ma Point Reset 3 Degrees for RT Remote Temperature Point Reset 3 Degrees for RT Remote Temperature Point Reset 4 ECW Setpoint Demand Limit Type Demand 1 Contact Demand 1 Contact Demand 1 Contact Demand 2 for ma ma Point Demand 2 for ma ma Point Auto Restart Option 23 0,1 16 Remote Contacts Option 24 0,1 16 Remote Ramp Rate

68 Table 7 Configuration Screen (Dual Compressor) Description Index Range Table Number Temperature Reset Type Reset 1 Temperature Degrees Reset for Temp Reset 2 Temperature Degrees Reset for Temp Reset 2 Degrees for ma ma Point Reset 2 Degrees for ma ma Point Reset 3 Degrees for RT Remote Temperature Point Reset 3 Degrees for RT Remote Temperature Point Reset 4 ECW Setpoint Demand Limit Type Demand 1 Contact Demand 1 Contact Demand 1 Contact Demand 2 for ma ma Point Demand 2 for ma ma Point Auto Restart Option 23 0,1 16 Remote Contacts Option 24 0,1 16 Remote Ramp Rate Lag A Shutdown Table Lag B Shutdown Table

69 Table 8 Maintenance Screen (Single Compressor) Description Index Range Table Number Diffuser Wall Position LCW Pump Relay Output 2 0, LCW Flow Input 3 0, Oil Pump Relay Output 4 0, Oil Pressure Switch Input 5 0, Cond. Pump Relay Output 6 0, Condenser Flow Switch Input 7 0, Tower Fan Relay Output 8 0, Purge Pump Relay Output 9 0, Purge Pump Switch Input 10 0, Alarm Relay Output 11 0, Spare Protection Limit Input 12 0, Compressor 1CR Output 13 0, Compressor 1CR Aux Contact14 0, Compressor Aux Run Contact 15 0, Comp. Start Circuit Volt 16 0, Motor Temp. Switch Input 17 0, Guide Vane Increase 18 0, Guide Vane Decrease 19 0, Diffuser Wall Increase 20 0, Diffuser Wall Decrease 21 0, Impeller Displacement Input 22 0,

70 Table 9 Maintenance Screen (Dual Compressor) Description Index Range Table Number Diffuser Wall A Position Diffuser Wall B Position LCW Pump Relay Output 3 0, LCW Flow Input 4 0, Oil Pump Relay Output 5 0, Oil Pressure Switch Input 6 0, Cond. Pump Relay Output 7 0, Cond. Flow Switch Input 8 0, Tower Fan Relay Output 9 0, Purge Pump Relay Output 10 0, Purge Switch Input 11 0, Alarm Relay Output 12 0, Spare Protection Limit Input 13 0, Comp. A 1CR Output 14 0, Comp. A 1CR Aux Contact 15 0, Comp. A Aux Run Contact 16 0, Comp. A Start Circuit Volt 17 0, Motor A Temp. Switch Input 18 0, Guide Vane A Increase 19 0, Guide Vane A Decrease 20 0, Diffuser Wall A Increase 21 0, Diffuser Wall A Decrease 22 0, Comp. B 1CR Output 23 0, Comp. B 1CR Aux Contact 24 0, Comp. B Aux Run Contact 25 0, Comp. B Start Circuit Volt 26 0, Motor B Temp. Switch Input 27 0, Guide Vane B Increase 28 0, Guide Vane B Decrease 29 0, Diffuser Wall B Increase 30 0, Diffuser Wall B Decrease 31 0,

71 Configuration Sheets

72 59

73 60

74 61

Product Data. Features/Benefits. 50RLP Water Source Heat Pumps System Control Panel

Product Data. Features/Benefits. 50RLP Water Source Heat Pumps System Control Panel Product Data 0RLP Water Source Heat Pumps System Control Panel TM Single packaged system control panel for use with Aquazone water source heat pumps in stand-alone or direct digital control applications

More information

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers Engineering Data SED: 8012 Group: Centrifugal Chiller Date: March 2002 Supercedes: New Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers Model WSC/WDC 2002 McQuay International

More information

What is the Carrier ChillerVu series counterflow application?

What is the Carrier ChillerVu series counterflow application? Carrier ChillerVu 23XRV Series Counterflow Application Guide CARRIER CORPORATION 2017 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-578-01 4/5/2017 Verify that

More information

ADDENDUM WCFX. Vision 2020i Touch Screen Controller. - a1 - Vision 2020i Controller

ADDENDUM WCFX. Vision 2020i Touch Screen Controller. - a1 - Vision 2020i Controller WCFX Vision 2020i Touch Screen Controller - a1 - 1.4 VISION 2020i CONTROLLER AND TERMINAL 1.4.1.1 The fourteen touch keys: Key Description MAIN Display the main screen Vision 2020i controller is equipped

More information

700 SERIES DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL

700 SERIES DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL 1 700 SERIES DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM 700 DPC MANUAL 072114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

FCU-4 FAN COIL CONTROLLER

FCU-4 FAN COIL CONTROLLER FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced

More information

WSHP-IOP-2 May Installation, Operation, and Programming. Tracer ZN510 Controller

WSHP-IOP-2 May Installation, Operation, and Programming. Tracer ZN510 Controller WSHP-IOP-2 May 1998 Installation, Operation, and Programming Tracer ZN510 Controller Literature History The Trane Company has a policy of continuous product improvement and it reserves the right to change

More information

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.

More information

4-step Chiller and Heat Pump Controller

4-step Chiller and Heat Pump Controller 4-step Chiller and Heat Pump Controller Technical Data Sheet GENERAL DESCRIPTION MODELS CODE MODEL DESCRIPTION MW324000 ECH 420 HEAT PUMP WITH 4 STEPS/ 2 CIRCUITS + MODBUS MW324005 ECH 420/V WITH SCREW

More information

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q AQUASNAP 30RB060-390 Air-Cooled Liquid Chillers with COMFORTLINK Controls 60 Hz Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q INDEX* POWER SCHEMATICS 30RB Unit Size Voltage Figure Number Label

More information

700 SERIES TPC TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

700 SERIES TPC TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL 1 700 SERIES TPC TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM 700SERIESTPCMANUAL071414 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features

More information

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number 30GXN,R Sizes 080-528 Air-Cooled Chillers with ComfortLink Controls 50/60 Hz Wiring Diagrams DIAGRAM INDEX POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number Label Diagram No. 30GX 080-178* ALL 1 505429

More information

FX2-CHILLER. Digital Control. Operations Manual

FX2-CHILLER. Digital Control. Operations Manual FX2-CHILLER Digital Control Operations Manual Micro Air Corporation Phone (609) 259-2636 124 Route 526 www.microair.net Allentown NJ 08501 Fax (609) 259-6601 Introduction: The FX2-CHILLER digital control

More information

Safety Instructions 1-1 Avoid unintended Start General Description 2-2

Safety Instructions 1-1 Avoid unintended Start General Description 2-2 Contents Contents 1 Safety and precautions 1-1 Safety Instructions 1-1 Avoid unintended Start. 1-1 2 Introduction 2-1 General Description 2-2 3 Supported Configuration 3-1 Introduction 3-1 Fixed-speed

More information

19XR CONTROLS UPGRADE with Optional VFD control

19XR CONTROLS UPGRADE with Optional VFD control MCS Total Solutions for all your HVAC/R Control Needs 19XR CONTROLS UPGRADE with Optional VFD control This brochure describes a standard upgrade package for the 19XR CHILLER. Each Control upgrade installation

More information

Operating Instructions Extended Cascade Controller MCO 101

Operating Instructions Extended Cascade Controller MCO 101 Operating Instructions Extended Cascade Controller MCO 101 VLT AQUA Drive FC 200 Extended Cascade Controller Option Contents Contents 1. Safety and precautions 3 Safety Instructions 3 Avoid unintended

More information

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,

More information

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling IBM Symposium 2008 Data Center Cooling EC Systems for HVAC architecture and Direct air Cabinet Cooling Presented by David J. Spofford Product Manager IT/Telecomm 1 Agenda Data Center trends for IT and

More information

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours! Data sheet MK 20 GR Customized solution or off-the-shelf: The choice is yours! MK20-GR data sheet Looking for a quick and reliable solution? Then rely on our standard products: Our universal controls provide

More information

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02 pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02 pco 3 Controller User Manual Introduction The Airstack Chiller is a modular air-cooled chiller composed of

More information

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015 ESC 201 Installation and Operating Instructions Manual SG-0002-03 Jan 2015 Table of Contents 1.0 FUNCTIONS... 5 2.0 FEATURES... 5 3.0 ESC 201 DESCRIPTION... 6 4.0 GENERAL OPERATIONS... 6 4.1 MANUAL MODE

More information

PEH-WSC CONTROLS UPGRADE with Optional VFD control

PEH-WSC CONTROLS UPGRADE with Optional VFD control MCS Total Solutions for all your HVAC/R Control Needs PEH-WSC CONTROLS UPGRADE with Optional VFD control This brochure describes a standard upgrade package for the PEH-WSC Chillers. Each Control upgrade

More information

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification. Assembly 025F0348

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification. Assembly 025F0348 Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification Assembly Revision History ECN # Date Rev Description By EC77363 03/15/17 A Initial Release K. Jones EC81620 11/15/17 B Added Agency

More information

GE Power Management. MMII Intelligent MCC Controller

GE Power Management. MMII Intelligent MCC Controller A concept that will offer reduced overall installed cost and production efficiency through information availability to operators and maintenance. Presentation Overview 6 Applications 6 Protection and Control

More information

Brushless DC Motor Controller Product Specification Assembly 025F0200

Brushless DC Motor Controller Product Specification Assembly 025F0200 Product Specification Assembly 025F0200 Revision History ECN # Date Rev Description By EC40382 071811 A Initial Release D. Stahl EC81620 11/15/17 B Added Agency Approval S. Lavey Page 1 of 11 Table Of

More information

Brushless DC Motor Controller Product Specification Assembly 025F0219

Brushless DC Motor Controller Product Specification Assembly 025F0219 Product Specification Assembly Revision History ECN # Date Rev Description By EC46310 6/14/12 A Initial Release Z. Sheu EC63683 01/27/15 B Correct interface connector part number D. Stahl EC81620 11/15/17

More information

A drive dedicated to variable speed control for HVAC applications

A drive dedicated to variable speed control for HVAC applications A drive dedicated to variable speed control for HVAC applications Designed for easy installation in mechanical fan and pump systems with reliable connectivity to building automation networks. VTAC 9 Drive

More information

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Table of Contents Introduction...

More information

Carrier Hong Kong Limited. Carrier Comfort Network. - optimizes the performance of HVAC Systems & is the premier solution for Building Control

Carrier Hong Kong Limited. Carrier Comfort Network. - optimizes the performance of HVAC Systems & is the premier solution for Building Control Carrier Hong Kong Limited Carrier Comfort Network - optimizes the performance of HVAC Systems & is the premier solution for Building Control Carrier Comfort Network Fire Systems Lifts & Elevators Plumping

More information

JEFFERSON COLLEGE COURSE SYLLABUS HRA249 COMMERCIAL REFRIGERATION SYSTEMS. 5 Credit Hours. Prepared by William Kaune November 30, 2010

JEFFERSON COLLEGE COURSE SYLLABUS HRA249 COMMERCIAL REFRIGERATION SYSTEMS. 5 Credit Hours. Prepared by William Kaune November 30, 2010 JEFFERSON COLLEGE COURSE SYLLABUS HRA249 COMMERCIAL REFRIGERATION SYSTEMS 5 Credit Hours Prepared by William Kaune November 30, 2010 Revised by William Kaune April 25, 2012 Mary Beth Ottinger, Ph.D., Division

More information

YK CENTRIFUGAL LIQUID CHILLER

YK CENTRIFUGAL LIQUID CHILLER YK CENTRIFUGAL LIQUID CHILLER OptiView Control Panel OPERATION INSTRUCTION Effective from 11/00 GB i 160-54-OI-GB0 Contents 1 HOME SCREEN 4 2 SYSTEM SCREEN 5 3 EVAPORATOR SCREEN 6 4 CONDENSER SCREEN 8

More information

MICROCOMPUTER CONTROL CENTER PART NO. FOR

MICROCOMPUTER CONTROL CENTER PART NO. FOR RENEWAL PARTS CENTRIFUGAL LIQUID CHILLERS Supersedes: See Back Cover Form 160.48-RP3 (1197) MICROCOMPUTER CONTROL CENTER PART NO. FOR 371-01200-002 ELECTROMECHANICAL STARTER, SOLID STATE STARTER AND TURBO-MODULATOR

More information

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers. General Information CFW10 CFW100 CFW08 CFW500 CFW700 CFW701 CFW11 EDP11 CFW11M SSW05 SSW07 GPH2 TPH2 The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which

More information

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions GRUNDFOS INSTRUCTIONS Control MPC Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions CONTENTS Page

More information

RTAA CONTROLS UPGRADE

RTAA CONTROLS UPGRADE MCS Total Solutions for all your HVAC/R Control Needs RTAA CONTROLS UPGRADE This brochure describes a standard upgrade package for the RTAA Chiller. Each Control upgrade installation is unique. It may

More information

User Guide. FreeCool : Free Cooling unit V1.1 ENGY-SVU001A-GB

User Guide. FreeCool : Free Cooling unit V1.1 ENGY-SVU001A-GB User Guide FreeCool : Free Cooling unit V1.1 ENGY-SVU001A-GB Table of Contents Introduction...3 General features...4 User interface...5 Top display area... 5 Bottom display area... 5 Main display area...

More information

700 SERIES FLOAT OPERATED DUPLEX/TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

700 SERIES FLOAT OPERATED DUPLEX/TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL 1 700 SERIES FLOAT OPERATED DUPLEX/TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM 700 SERIES FLOAT OPERATED DUPLEX/TRIPLEX PUMP MANUAL 042814 TABLE OF CONTENTS 2 INTRODUCTION

More information

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

SED2 Variable Frequency Drives with Electronic (E) Bypass Options SED2 Variable Frequency Drives with Electronic (E) Options Description The E- Options are companion packages for the family of SED2 Variable Frequency Drives (s). For information on the family of SED2

More information

SSW06. Soft Starters.

SSW06. Soft Starters. The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which provide visibility and make programming easier. Integral bypass contacts eliminate heat dissipation

More information

Sierra 80 Volt Brushless DC Motor Controller Product Specification

Sierra 80 Volt Brushless DC Motor Controller Product Specification Sierra 80 Volt Brushless DC Motor Controller Product Specification Assembly 025F0135 600A0588 Rev. B January 29, 2010 025F0135 Brushless DC Motor Controller Page 1 Revision History ECN # Date Rev Description

More information

P216. Condenser fan speed controller. Product bulletin. Features

P216. Condenser fan speed controller. Product bulletin. Features P216 Condenser fan speed controller Product bulletin These controllers are designed for speed variation of single phase motors, especially for fan speed control on air cooled condensers. Head pressure

More information

Brushless DC Motor Controller Product Specification Assembly 025F0095

Brushless DC Motor Controller Product Specification Assembly 025F0095 Product Specification Assembly 025F0095 Revision History ECN # Date Rev Description By N/A 1/23/06 1 First issue A. Meeuwsen N/A 2/07/06 2 Added content A. Meeuwsen 06008 3/13/06 A Release for document

More information

BB5-Lite TECHNICAL MANUAL

BB5-Lite TECHNICAL MANUAL BB5-Lite TECHNICAL MANUAL Product Support 1800 354 434 CC - BB5 - LITE LITE with Plug & Play technology www.blackbox.net.au Designed by IAS in Brisbane Made in Australia Product Support 1800 354 434 www.ias.net.au

More information

310SV SINGLE VALVE GOVERNOR

310SV SINGLE VALVE GOVERNOR 310SV APPLICATION The 310SV is a fully integrated and configurable controller designed to startup, run, and protect single-valve steam turbines. The controller is designed to control steam turbines driving

More information

OpView Operator Interface for Woodward 505 and 505E Controls. Product Manual (Revision B) Original Instructions

OpView Operator Interface for Woodward 505 and 505E Controls. Product Manual (Revision B) Original Instructions Product Manual 85015 (Revision B) Original Instructions OpView Operator Interface for Woodward 505 and 505E Controls Installation and Operation Manual General Precautions Read this entire manual and all

More information

LC-1 Level Controller & Flow Monitor

LC-1 Level Controller & Flow Monitor The Level Controller and Flow Monitor provides a fully integrated Duplex Controller. The unit allows collecting 'rate of flow' information and the verification of the run time characteristics of the external

More information

Carrier ComfortChoice Touch ZigBee Certified Thermostat Technical Specifications

Carrier ComfortChoice Touch ZigBee Certified Thermostat Technical Specifications Carrier ComfortChoice Touch ZigBee Certified Thermostat Technical Specifications Physical & Operational Characteristics Height 4.75 Width 5.5 Thickness (Stacked) 1.3 Thickness (User Interface, Un-stacked)

More information

BACnet MS/TP Interface User s Guide

BACnet MS/TP Interface User s Guide PoolPak MPK with CommandPak Control System CPCS BACnet MS/TP Interface User s Guide DOCUMENT #: SVW07-BACNET-MSTP-20171020 UPDATED: OCTOBER 2017 INTRODUCTION PoolPak dehumidifiers equipped with an CommandPak

More information

PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner

PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION Revised Last Revised by Alex Messner This page was intentionally left blank. Table of Contents 1 Overview... 2 2 User Interface... 3 2.1 LEDs... 3 2.2 Buttons...

More information

DNP Points List and Implementation

DNP Points List and Implementation S&C IntelliCap Plus Automatic Capacitor Control DNP Points List and Implementation Table of Contents Section Page Section Page DNP Points List for IntelliCap Plus Controls...1 Status Points....2 Analog

More information

FRICK QUANTUM HD UNITY SYSTEM CONTROLLER

FRICK QUANTUM HD UNITY SYSTEM CONTROLLER Form 090.670-O (AUG 2015) OPERATION File: SERVICE MANUAL - Section 90 Replaces: NOTHING Dist: 3, 3a, 3b, 3c OPERATION FRICK QUANTUM HD UNITY SYSTEM CONTROLLER ENGINE ROOM CONDENSER VESSEL EVAPORATOR Version

More information

Quantum HD Release Notes

Quantum HD Release Notes Quantum HD Release Notes OS Version 10.17 Released 7-14-2014 To upgrade to OS version 10.17 directly the current OS version must be 10.13 through 10.16. To check the current OS version on the Quantum HD

More information

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SED2 VFD NEMA Type 3R Bypass/Air Conditioner SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications

More information

Temperature controller Ducted systems

Temperature controller Ducted systems 2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master

More information

Copyright: December 2017 Nidec Issue: E

Copyright: December 2017 Nidec Issue: E General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional parameters of the equipment

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

Athena Series RMC Hot Runner Controller Configuration and Operation Manual

Athena Series RMC Hot Runner Controller Configuration and Operation Manual Athena Series RMC Hot Runner Controller Configuration and Operation Manual Athena and CompuStep are registered trademarks, and Multi-Comm and SafeChange are trademarks of Athena Controls, Inc. MODBUS is

More information

90F Guy L Warden & Sons Thrush Model 720 4 X 2.5 Flow Guide 90F Guy L Warden & Sons 90F PART 1 GENERAL OVERVIEW Product Scope: SECTION 15 iqpump ENGINEERING SPECIFICATIONS VARIABLE FREQUENCY DRIVES The

More information

2301E ST Steam Turbine Control for Small Generator Applications

2301E ST Steam Turbine Control for Small Generator Applications 2301E ST Steam Turbine Control for Small Generator Applications Product Specification 03407 (Revision A, 12/2014) Applications The 2301E-ST is a steam turbine control with internal algorithms designed

More information

VILTech micro-controller. Operation and service manual

VILTech micro-controller. Operation and service manual VILTech micro-controller Operation and service manual 2 Important Note: Before applying power to the control panel, all wiring to the panel should be per NEC. Specifically check for proper voltage and

More information

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95 Part 1 - GENERAL ASEA BROWN BOVERI ABB Industrial Systems Inc. Standard Drives ACH500-06E Effective 6/1/95 Sample Specification for Adjustable Frequency Drives (2 to 400 HP) for Variable Torque Applications

More information

Installation and Operation Instructions

Installation and Operation Instructions 33ZC ComfortID Test and Balance Tool Software Installation and Operation Instructions Part Number 33ZCBAL-SA INSTALLATION The ComfortID Test and Balance Tool software requires no special installation.

More information

MICROCOMPUTER CONTROL CENTER

MICROCOMPUTER CONTROL CENTER OPERATION ROTARY SCREW LIQUID CHILLERS Supersedes: See Back Cover Form 160.47-O1.1 (197) MICROCOMPUTER CONTROL CENTER PART NO. 371-01112-001 or 371-01200-003 FOR MODEL YS BA BA S0 THRU YS FC FB S5 (STYLE

More information

FX 2 Instruction Manual

FX 2 Instruction Manual FX 2 Instruction Manual Climma Compact Version Annapolis MD USA 301 352 6962 info@veco-na.com Introduction: The FX2-DX digital controller operates onboard air conditioning equipment to provide room temperature

More information

User Guide. Tracer TD7 with UC 800 for CGAF chillers. CG-SVU010A-GB Original instructions

User Guide. Tracer TD7 with UC 800 for CGAF chillers. CG-SVU010A-GB Original instructions User Guide Tracer TD7 with UC 800 for CGAF chillers CG-SVU010A-GB Original instructions Copyright All rights reserved This document and the information in it are the property of Trane and may not be used

More information

INTRODUCTION. FX-1 Operations Manual. Standard Features. Optional Features. Read This Manual Completely Before Proceeding!

INTRODUCTION. FX-1 Operations Manual. Standard Features. Optional Features. Read This Manual Completely Before Proceeding! INTRODUCTION The FX-1 Control is designed for use with all direct expansion, reverse cycle air conditioning systems. FX-1 has a universal power supply that operates on 115, 230, 50 or 60 Hz AC power. FX-

More information

LC-5 Level Controller & Flow Monitor

LC-5 Level Controller & Flow Monitor The Level Controller and Flow Monitor provides a fully integrated Duplex Controller supporting both analog and discrete (float switch) level detection. The unit allows collecting 'rate of flow' information

More information

FCU-4 FAN COIL CONTROLLER

FCU-4 FAN COIL CONTROLLER FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced

More information

SECTION VARIABLE FREQUENCY DRIVES

SECTION VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 DESCRIPTION This specification section establishes the requirements for variable frequency motor drives. The associated motor(s) shall be specified separate from the drive and listed

More information

Custom Controller Installation Instructions

Custom Controller Installation Instructions MODEL CUSTOM CONTROLLER HARDWARE CODE MAX ALLOWABLE AMBIENT TEMP: 70 C (158 F) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1) THIS DEVICE MAY

More information

Application Engineering

Application Engineering Application Engineering Application Engineering Commercial Comfort Controller (543-0175-00) Installation Guide May 2012 Contents Mounting... 1 Connections and Wiring... 1 Wiring Considerations... 1 Input

More information

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification General The VT76xxW series is designed for single-stage and multi-stage control of water source heat pumps with dedicated

More information

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

M1000 INTELLIGENT ZONE CONTROL SYSTEM

M1000 INTELLIGENT ZONE CONTROL SYSTEM HARDWARE GUIDE DIMENSIONS & SPECIFICATIONS REV. 5.2 M1000 INTELLIGENT ZONE CONTROL SYSTEM ROOFTOP CONTROLLER 2 Table of Contents GENERAL INFORMATION... 3 PL-M1000 Rooftop Controller...3 Description...3

More information

SED2 Variable Frequency Drives

SED2 Variable Frequency Drives SED2 Variable Frequency Drives Startup Procedure and Checklist Document No. 155-718 Table of Contents Prerequisites...1 Preparing for SED2 VFD Startup...1 HVAC Startup Procedure for SED2 with Bypass Option...4

More information

Millennium Simplicity Elite Parameter Points and Quirks

Millennium Simplicity Elite Parameter Points and Quirks Millennium Simplicity Elite Parameter Points and Quirks How to access, view and change parameter settings Program Button Test Reset UP Alarms Change Data Address Down 1. Push the Program button once. The

More information

LC-3 Flow Monitor & Pump Run Verification

LC-3 Flow Monitor & Pump Run Verification The Flow Monitor and Pump Verification unit allows collecting 'rate of flow' information on existing Duplex Pump control systems and the verification of the run time characteristics of the external pumps.

More information

Installation and Operation Manual. OpView Operator Interface for Woodward 505 and 505E Controls. Manual (Revision B)

Installation and Operation Manual. OpView Operator Interface for Woodward 505 and 505E Controls. Manual (Revision B) Installation and Operation Manual OpView Operator Interface for Woodward 505 and 505E Controls Manual 85015 (Revision B) DEFINITIONS This is the safety alert symbol. It is used to alert you to potential

More information

Vertex Pro Motor Driven Compressor Control

Vertex Pro Motor Driven Compressor Control Product Specification 03364 (Rev. A) Description Vertex Pro Motor Driven Compressor Control The Vertex-Pro is an anti-surge controller, designed to control and protect industrial-sized motor-driven axial

More information

D/E Remote Relay Panel User Guide

D/E Remote Relay Panel User Guide D/E Remote Relay Panel User Guide This manual should remain with the unit. D/E Remote Relay Panel Detailed Specifications...2 Environmental Specs...2 Power Supply Requirements...2 Relay Outputs (8)...2

More information

Modbus Register Map: InRow ACRD60x / ACRC60x

Modbus Register Map: InRow ACRD60x / ACRC60x Modbus Map: InRow ACRD60x / ACRC60x Notes: 1. 16-bit registers (INT16, UINT16, ENUM) are transmitted MSB first (i.e., big-endian). 2. INT32 and UINT32 are most-significant word in n+0, least significant

More information

1 Extended and Advanced Cascade Controller Option 3

1 Extended and Advanced Cascade Controller Option 3 VLT Operating Instructions Contents Contents Extended and Advanced Cascade Controller 3 How to read these Operating Instructions 3 High Voltage Warning 3 Safety Instructions 3 Avoid unintended Start 3

More information

PF MODBUS REGISTER MAP. v1.4 Revised Nov 29, 2016

PF MODBUS REGISTER MAP. v1.4 Revised Nov 29, 2016 PF3107-00 MODBUS REGISTER MAP v1.4 Revised TRADEMARKS AND COPYRIGHT All content is subject to copyright and may not be reproduced in any form without the express written consent of the author. 2016 Profire

More information

SS2200 Remote Controller

SS2200 Remote Controller SS2200 Remote Controller General Purpose, DC Voltage General The SS2200 Remote Controller is a microprocessor-based programmable controller specifically designed to control single line and dual line centralized

More information

COND. A ENABLE RELAY CONTACT COOLA ENABLE 24 VAC. RATING IS 1 AMP COND. B ENABLE COOL B ENABLE.

COND. A ENABLE RELAY CONTACT COOLA ENABLE 24 VAC.   RATING IS 1 AMP COND. B ENABLE COOL B ENABLE. Factory Packaged Controls Coil Products Two Head Pressure Module Orion No.:OE370-23-HP2C 1 2 3 4 www.aaon.com www.orioncontrols.com Circuit A1 TRANSDUCER #1 Circuit A2 TRANSDUCER #2 Circuit B1 TRANSDUCER

More information

VLT 2800 DRIVE SPECIFICATIONS

VLT 2800 DRIVE SPECIFICATIONS VLT 2800 DRIVE SPECIFICATIONS Drive Input Power Input voltage 3 phase... 200 through 240, or 380 through 460; 3-phase all ratings 200 through 240, 1-phase through 2 HP Input voltage range for full output...

More information

Bell & Gossett. Technologic 500 Pump Controller. Bulletin D-125. The Most Reliable and Affordable Solution for Variable Speed Pumping Systems.

Bell & Gossett. Technologic 500 Pump Controller. Bulletin D-125. The Most Reliable and Affordable Solution for Variable Speed Pumping Systems. Bell & Gossett Bulletin D-125 Technologic 500 Pump Controller The Most Reliable and Affordable Solution for Variable Speed Pumping Systems. Integrated Pump Controller and Adjustable Frequency Drive. Controls

More information

PoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP

PoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP PoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP-20171020 UPDATED: OCTOBER 2017 INTRODUCTION PoolPak dehumidifiers equipped with an CommandPak Control

More information

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP. DIVERSIFIED HEAT TRANSFER SERIES 700 STEAM GENERATOR CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE AT SIGMACONTROLS.COM SERIES 700 DHT STEAM GENERATOR MANUAL 042514 2 TABLE OF CONTENTS INTRODUCTION.

More information

TECHNICAL MANUAL WATER 300 C 5300 CV/06-00 GB

TECHNICAL MANUAL WATER 300 C 5300 CV/06-00 GB T E C H N I C A L M A N U A L TECHNICAL MANUAL C 5300 CV/06-00 GB GB The information contained in this document may be modified without prior notice and is in no way binding, even implicitly, for CLIMAVENETA.

More information

Baltimore Aircoil Company

Baltimore Aircoil Company Baltimore Aircoil Company VFD Startup Guide TABLE OF CONTENTS: A. Verifying Power and Control Wiring...1 B. Setting the VFD Parameters...2 C. Reentering Startup Wizard After Initial Setup...5 D. Starting

More information

2301D ST Digital Load Sharing and Speed Control

2301D ST Digital Load Sharing and Speed Control Product Specification 03297 (Rev. E) 2301D ST Digital Load Sharing and Speed Control Applications The 2301D-ST is a field-configurable control designed for single-valve steam turbine applications. This

More information

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Table of Contents Introduction...

More information

Technologic 502 Variable Speed Pump Controller

Technologic 502 Variable Speed Pump Controller Qualify for Green Building Incentive Programs and Rebates Achieve LEED Certification Sustainable Water Conservation and Energy Efficiency Reduced Environmental Impact Lower Electric and Water Utility Costs

More information

CHILLER SYSTEM OPTIMIZER (CSO) User Manual TABLE OF CONTENTS. Section Description Page

CHILLER SYSTEM OPTIMIZER (CSO) User Manual TABLE OF CONTENTS. Section Description Page CSO User Manual CHILLER SYSTEM OPTIMIZER (CSO) User Manual TABLE OF CONTENTS Section Description Page I. Module Installation and Licensing 2 II. Chiller Plant Operations 5 III. General Status Main Page

More information

Drive inverter for asynchronous AC motors without encoder feedback. The units are not option capable.

Drive inverter for asynchronous AC motors without encoder feedback. The units are not option capable. MDX61B System overview MOVIDRIVE MDX60B/61B is the new generation of drive inverters from SEW EURODRIVE. The new series B MOVIDRIVE drive inverters, which feature a modular design, provide enhanced functions

More information

SELECTRONIX, INC. SUPERSTEP SERIES 4000 SEQUENCING STEP CONTROLLERS WOODINVILLE, WA INSTALLATION & OPERATING ADDENDUM LOAD LIMIT INPUT CONFIGURATIONS

SELECTRONIX, INC. SUPERSTEP SERIES 4000 SEQUENCING STEP CONTROLLERS WOODINVILLE, WA INSTALLATION & OPERATING ADDENDUM LOAD LIMIT INPUT CONFIGURATIONS SELECTRONIX, INC. WOODINVILLE, WA SUPERSTEP SERIES 4000 SEQUENCING STEP CONTROLLERS INSTALLATION & OPERATING ADDENDUM LOAD LIMIT INPUT CONFIGURATIONS Rev 03/10/19 2 1 Various DC Voltage - 100 % Load Limit

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. MCD Profibus Module Instructions Important User Information Installation Instruction: MCD Profibus Module Order Code: 175G9001 1. Important User Information Observe all necessary safety precautions when

More information

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter. www.sordselectric.com MA7200 Sensorless Vector AC Inverter Features and Benefits Sensorless Vector The MA7200 has precise speed and torque control for the most demanding system performance and simple set-up

More information

clarity 3 Programmable Controller

clarity 3 Programmable Controller clarity 3 Programmable Controller BACnet General Purpose Controllers (B-AAC) DESCRIPTION Taco Clarity 3 FPC series controllers are designed to control building systems and HVAC equipment. The integrated

More information