1 VERSION Installation Instructions (KF-2000) Keico Hightech, Inc.

2 Installation Instructions KF-2000 Keico Hightech Ace Twin Tower I 12 th FL 212-1, Guro-Dong, Guro-Gu Phone Fax

3 Contents 1. KF KF-2000 Contents KF-2000 Wall screw position KF-2000 Base (Rear) KF-2000 Description KF-2000 Connections (Power) KF-2000 PC Connections (RS-232) KF-2000 PC Connections (RS-422) KF-2000 Com Server RS-232 Connection KF-2000 Com Server RS-422 Connection KF-2000 Wiegand Output KF-2000 R/F Card Reader Conection KF-2000 Finger Reader Connection KF-2000 Sensor KF-2000 Relay KF-2000 Address KF-2000 Lock Connection KF-2000 Stand Alone

4 KF ) KF-2000 model 2) Fix plate 3) Screw Fixplate screw : 4ea Main unit screw : 6ea 4) Harness (7 pin: 2, 6 pin: 1, 5 pin: 1, 2 pin: 1)

5 Wall side fixation screw locations Fix KF-2000 on wall

6 KF-2000 base (back)

7 Tips before wiring (terms) 1) Connection points for power and weigand communication -This connection point is where 12V supplies the product from a power supply. User ID s are outputted as wiegand data. (in the case of connecting this product on a different main controller) 2) Sensor - Point to connect various sensors such as door contacts, security sensors or an exit button 3) Relay1, 2 -Point to connect door locks, or alarm devices 4) Serial Port -232,422 communication lines 5) Tamper Switch -Will sound an alarm when product is forced off a wall 6) Dummy Load -Set Dummy Load when connecting jumper 7) Controller Address Switch -This switch assigns each controller to separate address when several controllers (KF- 2000) are connected to a computer in order to differentiate

8 Line Connections (Power) On the back of the KF-2000 connect a DC 12V (1A) (8~24V) on the 7 pin connector as shown in the picture. Warning - Do not connect to a AC power supply. -Low power currents may effect operation - Make sure there are no problems with power before connecting

9 Line Connections (Power 2) - For the event of a power failure, a backup battery should be installed. - On the back of the circuit board, connect a DC 12V onto the connect power supply - Ground (GND) and Power supply line (VCC) are shown in the picture below. The pin left of the connector is VCC and the pin on the right is GND

10 RS-232 connection to the KF-2000 and Computer

11 Connection of the KF-2000 to the PC using the RS-232 -When connecting this product to a main computer within 15 meters, connect to the series port. -RS-232 only support single connection

12 RS-422 connection to the KF-2000 and Computer -As shown in the picture, it is possible to connect several KF-2000s on the line connecting the KF-2000 and PC. - However, one series port can support up to a maximum of 16 KF-2000

13 Tips before wiring (WAN) -As shown in the picture, when a main computer controls more than a maximum of 17 KF-2000s, you must connect the KF-2000s to more than one port -The number of ports needed to connect a certain number of KF-2000s are shown in the chart on the right

14 Connecting the KF-2000 to a PC using RS-422 This instruction is when controlling several controllers from a main computer that is more than 15 meters away. - Multiple lines coming from multiple controllers can be connected to the RS422 converter as shown below. (Maximum 16 controllers for one converter)

15 Connecting the KF-2000 to a PC using RS-422 As shown in the picture, this method is used when controlling several controllers that are more than 15 meters away from the main computer. - Multiple lines coming from multiple controllers can be connected to the RS422 converter as shown below. (Maximum 16 controllers for one converter)

16 Connecting the KF-2000 to a Com Server using an RS-232 -This wiring diagram shows how the KF-2000 communicates with a Hub using TCP/IP

17 Connecting the KF-2000 to a Com Server using an RS This wiring diagram shows how the KF-2000 communicates with a Hub using TCP/IP

18 Line Connections - Wiegand Output - The picture shown shows when connected to a different product, only that the KF-2000 will act as a reader. - This is not usually done only in special circumstances.

19 Line Connections RF Reader Connect the lines from the card reader to the connector on the main unit, when using the RF card reader. - The following picture shows the connection for KF-10 (Connections are the same for KP-20. (Connections can be different by each product. Refer to specific manuals.) - KF-2000 has Independent Card Reader Function (Optional). If this reader is used only 1 card reader can be connected. (If enabled card reader is not used, 2 external readers can be used independently)

20 Line Connections Finger Reader If connecting the KF-2000 with a fingerprint reader, refer to the picture shown. - Since the KF-2000 already has a fingerprint reader, only one fingerprint reader can be connected.

21 Connecting the KF-2000 Sensor 1 The KF-2000 can be connected to control different kinds of sensors other than controllers. - The picture shown displays a door contact connected to an exit button. - Wires from the door contact and exit button are connected as shown in the picture.

22 Line Connections Sensor 2 The picture shown displays how the KF-2000 controls a automatic sliding door and all devices related. - All lines that come from door contacts, sensors, exit buttons and infared sensors should be connected like the picture shown.

23 Line Connections Relay 1 KF-2000 uses the various signals received from the sensors (mentioned above) with other devices to physically control access events. - Devices such as electric strikes or alarms should be connected and activated via CN2 - Relay 1 can be used for signal alarms

24 Line Connections Relay 2 For additional security, use relay interface PCB for installation. (recommended installation) - Wiring installation is as follows. 1) Choose between DC12V or DC24V and connect. (the dotted lines indicate possible connect options) 2) When the door lock is unlocked in normal circumstances connect to NO on the PCB. Connect to NC when the door lock is locked in normal circumstances. 3) The connect methods of the Electric Strike differ case to case, please refer to the manual.

25 Line Connections Relay 3 Different from the previous page, the relay consists of one power supply - In case of a blackout, connect power through UPS -Connect the power with a DC 12V located in the back of the circuit board.

26 Alarm Relay Connection

27 KF-2000 Address setup Address switch - When setting up several KF-2000 s to a PC, this address is used so that the PC can recognize each KF-2000 that is connected individually (Mechanical method) - This can be setup in the KF-2000 program mode. (Logical method) - Priority is given to the logical method (Logical method) than the mechanical method (Mechanical method) (H/W). For example, if a switch is used for 3 and the same KF-2000 sets the address as 9 from a program, the program will recognize the address as 9 instead of 3-1 through F(16) is available.

28 Lock Connection

29 Lock Connection

30 KF-1000 Stand Alone Connection

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER Table of contents 1 PRODUCT INTRODUCTION... 2 1.1 NAME AND FUNCTION OF EACH PART... 2 1.2 CABLE COLOR TABLE... 4 1.3 CABLE SELECTION... 6 2 IDENTIFYING

More information

GENERAL QUICK START GUIDE

GENERAL QUICK START GUIDE GENERAL QUICK START GUIDE 2.8InchPalm & Fingerprint Time Attendance & Access Terminal Version: 1.0 Date: May., 2017 Note: The picture and function presented in this manual are only for reference. The following

More information

721EX Access Controller Installation

721EX Access Controller Installation 721EX Access Controller Installation 721EX Controller Standalone Controller Specifications Max Card Capacity: 3000 What is included in the box B-Id 721EX controller board RS485/Serial converter USB/Serial

More information

User Manual. Before using this device, read and follow all instructions for safety

User Manual. Before using this device, read and follow all instructions for safety User Manual Before using this device, read and follow all instructions for safety Copyrightc 2014 KJTECH Co., Ltd. All rights reserved. It is provided for informational purposes only in this manual. All

More information

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014 SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions

More information

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers NetGen Hardware Installation Guide for NetGen Ethernet Door Controllers 0613 Table of Contents BLUEWAVE SYSTEM OVERVIEW...2 THE WI-FI LOCK AND SECURITY COMPANY...2 NETGEN DOOR CONTROLLERS...2 INSTALLATION

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work

More information

Fingerprint Access Control F1. User Manual

Fingerprint Access Control F1. User Manual Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.

More information

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2 W Series Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2 W1 & W2 Features * Standard 2.8-inch TFT LCD, 512MB Flash, industrial high speed CPU * Touch keypad & touch active sensor

More information

Single Door Standalone Access Control User Manual

Single Door Standalone Access Control User Manual Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self

More information

Connecting a Cisco Output Module

Connecting a Cisco Output Module CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which

More information

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot Overview Fingerprint & Finger Vein Device Front Left Side: Finger Vein Device Touch screen Card reader Fingerprint reader Finger vein reader Finger vein sensor: During registration, after finger touches

More information

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web: ACCESS CONTROL QUICK INSTALL GUIDE tel: +44 (0)1457 874 999 fax: +44 (0)1457 829 201 email: sales@cop-eu.com web: www.cop-eu.com WIRING CONFIGURATION - ACS CONTROLLERS CONNECTIONS Dahua access controllers

More information

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode -Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add

More information

iface Series Installation Guide

iface Series Installation Guide iface Series Installation Guide Version:1.0 Date:Sep 2009 About this Guide This guide provides actual installation instructions only. For information regarding user instructions, please refer to iface

More information

To Contact Us. c Copyright , NITGEN Co., Ltd. All rights reserved

To Contact Us. c Copyright , NITGEN Co., Ltd. All rights reserved c Copyright 2003-2009, NITGEN Co., Ltd. All rights reserved Features and specifications are subject to change without notice. No part of this guide may be copied or reproduced for any purpose without the

More information

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating 1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without

More information

5.5 AS Layout. GeoVision Technical Handbook 77

5.5 AS Layout. GeoVision Technical Handbook 77 5.5 AS400 5.5.1 Layout GeoVision Technical Handbook 77 5.5.2 Wiegand Reader Connection AS400 supports up to eight Wiegand 26 ~ 64bit readers Wiegand connection has a distance limitation of 30m (~ 100ft)

More information

Connecting a Cisco Input Module

Connecting a Cisco Input Module CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each

More information

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed F18 Features: 1. 2.4 TFT LCD color screen 2. Standard Wiegand Input and Output interfaces are compatible with most all 3 rd party 26 bit Wiegand readers and access control panels. 3. USB HOST port makes

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

Connecting a Cisco Reader Module

Connecting a Cisco Reader Module CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco

More information

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud

More information

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It

More information

Quick Start Guide. GV-AS / EV Controller

Quick Start Guide. GV-AS / EV Controller Quick Start Guide GV-AS / EV Controller Thank you for purchasing GV-AS / EV Controller (GV-AS100 / AS110 / AS120 / AS210 / AS400 / AS410 / AS810 and GV-EV48). This guide is designed to assist the new user

More information

GV-AS200 Controller. Hardware Installation Guide

GV-AS200 Controller. Hardware Installation Guide GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.

More information

Secrure door control and I/O expansion. Installation Guide. (ver 1.0)

Secrure door control and I/O expansion. Installation Guide. (ver 1.0) Secrure door control and I/O expansion Installation Guide (ver 1.0) www.supremainc.com Contents Product Contents 3 Front Panel Description 4 Rear Panel Description 5 Connectors for External Interfaces

More information

Installation & User Manual V2.08

Installation & User Manual V2.08 YOUR SECURITY IS OUR PRIORITY Other products from GSD Contents Installation Instructions Installation Diagrams System Overview Wiring Diagrams Network Diagrams Operation Instructions Fingerprint Enrollment

More information

Innovative Fingerprint Terminal Installation Guide

Innovative Fingerprint Terminal Installation Guide www.supremainc.com Innovative Fingerprint Terminal Installation Guide EN 101.00.BST (ver V1.31 1.1) Contents Product Contents 3 Connectors for External Interfaces 5 Cable and Connector Pinout 6 Installation

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Quick Start Guide. SEB-710 I/O Expansion board. Introduction SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay

More information

CP150B Vandal & Weather Resistant Keypad Security Systems

CP150B Vandal & Weather Resistant Keypad Security Systems Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected

More information

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate www.zkaccess.com Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate Power Connection Ethernet Connection

More information

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual RD-SR2 Proximity Card Reader with Remote Control User Manual INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control

More information

NS1 Connection Unit Guide

NS1 Connection Unit Guide PURPOSE AND APPLICATION Connection Unit Guide The connection unit is an installation friendly device, which makes it possible to use all features from a central unit. The CU can also be used to connect

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated: Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact

More information

Installation & User Manual

Installation & User Manual Contents Installation Instructions 3 Installation Diagrams 4 System Overview 6 Wiring Diagrams 8 Network Diagrams 9 Operation Instructions Fingerprint Enrollment 12 21 Wi-Enterprise Controller www.transmittersolutionssmart.com

More information

GV-AS Controller. Installation Guide

GV-AS Controller. Installation Guide GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information

Stand-alone Proximity Access Control

Stand-alone Proximity Access Control Stand-alone Proximity Access Control User Manual INTRODUCTION VIDI-AC-1C is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. It uses

More information

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad

More information

Comfort, the Intelligent Home System. Comfort Fingerprint Reader Interface FPR01

Comfort, the Intelligent Home System. Comfort Fingerprint Reader Interface FPR01 Comfort, the Intelligent Home System Comfort Fingerprint Reader Interface FPR01 Introduction to the Comfort Fingerprint Reader Interface... 1 Specifications... 2 Equipment... 2 Settings... 2 Connections...

More information

IPM500 Series QuickStart Manual

IPM500 Series QuickStart Manual IPM500 Series QuickStart Manual The Force of Innovation 10 Thomas Irvine, CA 92618 USA (949) 465-0900 FAX: (949) 465-0905 E-Mail: HTUfutek@futek.comUTH www.futek.com Manufacturer of Load Cells, Pressure

More information

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. ASEV-H 2016 GeoVision, Inc. All rights

More information

Access Control System

Access Control System Access Control System Version 3.0 Hardware and Software Installation Guide Long Range RFID (UHF) Readers and Tags Specialist Smart Key Access Control System Installation Guide i Smart Key Contact Information

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

Fingerprint Identification Proximity Reader. Quick Installation Guide

Fingerprint Identification Proximity Reader. Quick Installation Guide Fingerprint Identification Proximity Reader Quick Installation Guide 1. WHAT S INCLUDED Please unpack and check the contents of the box. If any of these parts are missing, please contact a nearby distributor

More information

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01 Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation

More information

Installation Guide. UHF RFID Integrated Machine: U1000E, U1000F, U2000E, U2000F. Version: 1.0 Date:

Installation Guide. UHF RFID Integrated Machine: U1000E, U1000F, U2000E, U2000F. Version: 1.0 Date: Installation Guide UHF RFID Integrated Machine: U1000E, U1000F, U2000E, U2000F Version: 1.0 Date: 2017.09 1. Overview Front View Antenna Working Frequency: 902MHz 928MHz 865MHz 868MHz Read Range: U1000E/F

More information

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

genesis TECHNICAL MANUAL Two-Door Controller GEN-045 Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4

More information

SETUP GUIDE INSTALLATION HANDBOOK. For Integrators, Installers and Administrators. Everything on how to get Kisi up and running. getkisi.

SETUP GUIDE INSTALLATION HANDBOOK. For Integrators, Installers and Administrators. Everything on how to get Kisi up and running. getkisi. SETUP GUIDE INSTALLATION HANDBOOK For Integrators, Installers and Administrators Everything on how to get Kisi up and running getkisi.com 1 TABLE OF CONTENT 13 14 INSTALLING KISI AS A STAND-ALONE SYSTEM

More information

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1 15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...

More information

Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules

Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules This guide supplements the Synergis Master Controller Configuration Guide and explains how to configure Axis interface modules

More information

A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address

A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address Requirements A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address Power Up A Reader with an Ethernet adaptor installed and the network cable

More information

Fingerprint and Card Reader User Manual

Fingerprint and Card Reader User Manual Fingerprint and Card Reader User Manual UD01679N User Manual This Manual is applicable to Card Reader. The Manual includes instructions for using and managing the product. Pictures, charts, images and

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

Wiring Inside the card reader you will see a circuit board. The connections are as follows: Power Adaptor (12VDC, Max. Current: 1A) If you purchased the Cardlock Series power supply cut the head of the adaptor and strip the insulation. If your locking mechanism, electric strike or magnetic lock

More information

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated: Wiring Guide EP.L3800 Version 1.03 Last Updated: 13-10-2014 1 Note: L3800 is the serial enabled lift controller. L3800 will ship with a HIO board in a package which can cater up to 8 floors. It can connect

More information

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver

More information

Two-door Access Controller

Two-door Access Controller Two-door Access Controller Quick Start Guide V1.0.0 Preface Overview This document elaborates on structure, installation, interface and wiring of two-door access controller. Symbol Definition The following

More information

MS-7000: SuperStar Reader

MS-7000: SuperStar Reader The MS-7000 SuperStar Reader The MS-7000 SuperStar Reader is intended for installation in proximity applications where an extended read range is required. The reader provides an audio beeper and a multi

More information

Bewator Granta Controller Installation Handbook

Bewator Granta Controller Installation Handbook Bewator Granta 4101-2 Controller Installation Handbook Copyright 2004 Bewator AB, Solna. This handbook is based on the best information available to Bewator Cotag at the time of publication. Although every

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-C

More information

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection LAN Connection RS485 Connection Relay Connection Digital

More information

Quick Start Guide. GV-CS1320 Camera Access Controller

Quick Start Guide. GV-CS1320 Camera Access Controller Quick Start Guide GV-CS1320 Camera Access Controller Thank you for purchasing GV-CS1320 Camera Access Controller. This guide is designed to assist the new user in getting immediate results from the controllers.

More information

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions F7_F707_F708 Access Control Terminal Installation Instructions Revised May 2008 About this Guide This guide provides installation instructions only. For information regarding actual operation and configuration

More information

smartentry Wireless Video Doorphone User Manual

smartentry Wireless Video Doorphone User Manual smartentry Wireless Video Doorphone User Manual Designed & Engineered Version 1.2 in the United Kingdom Contents Precautions... 3 1. Product Overview... 4 1.1. Product Features... 4 1.2. Contents... 4

More information

BIOC3 V1 USER S MANUAL. Biometric Reader v. b1

BIOC3 V1 USER S MANUAL. Biometric Reader v. b1 BIOC3 V1 EN Biometric Reader USER S MANUAL v. b1 www.xprgroup.com 1 Contents 1. DESCRIPTION 2. SPECIFICATIONS 3. MOUNTING 4. WIRING 5. CONNECTING BIOMETRIC READERS TO EWS CONTROLLER 5.1 CONNECTING BIOMETRIC

More information

iclock serial Time & Attendance and Access Control Terminal Installation Instructions

iclock serial Time & Attendance and Access Control Terminal Installation Instructions iclock serial Time & Attendance and Access Control Terminal Installation Instructions About this Guide This guide provides installation instructions only. For information regarding actual operation and

More information

_ Access control SISTEMAS DE SEGURIDAD

_ Access control SISTEMAS DE SEGURIDAD _ Access control SISTEMAS DE SEGURIDAD SECURITY SYSTEMS Access control 01 Concept 02 Product 03 Characteristics 04 Compatibility 05 New functions 06 New software 07 References, accessories and diagrams

More information

ImproX IXP20 Controller INSTALLATION MANUAL

ImproX IXP20 Controller INSTALLATION MANUAL MODEL NUMBER: ISC920-0-0-GB-XX ISC921-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series One Door TCP/IP Web Server Controller. Model: ACP-DXEL1 to ExitPushAccessAccessBoard PWR-

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series One Door TCP/IP Web Server Controller. Model: ACP-DXEL1 to ExitPushAccessAccessBoard PWR- QUICK START GUIDE FOR ACCESS CONTROL BOARDS DX Series One Door TCP/IP Web Server Controller Model: ACP-DXEL1 to ExitPushAccessAccessBoard PWR- Table of Contents 3 01- Introduction 4 02 - Overview 4 02.1

More information

Waterproof. Keypad/Reader/Controller

Waterproof. Keypad/Reader/Controller Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing

More information

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,

More information

TFT screen Fingerprint Machine

TFT screen Fingerprint Machine TFT screen Fingerprint Machine Installation Instruction V1.1 TFT screen Fingerprint Machine Installation Instruction Contents About this Guide The TFT screen Fingerprint Machine User guide is designed

More information

F & SC Serial Access Control Station. Installation Guide

F & SC Serial Access Control Station. Installation Guide F & SC Serial Access Control Station Installation Guide About this Guide The F&SC Access Control Station User guide is designed to provide information to install the F& SC serial Access Control Station,

More information

Installation manual CF8-W-Disp-AL

Installation manual CF8-W-Disp-AL Installation manual CF8-W-Disp-AL CO 2 transmitter with two relays mounted in industrial housing prepared for Modbus communication protocol 4 7 8 8 6 3 2 5 Wall plate 5 Snap-in lid 2 PCB (Factory supplied

More information

icam7000s SERIES HARDWARE GUIDE Packing List CONTACTLESS CARD READER RECESS MOUNT (Optional) ISO/ANSI COMPLIANT EASY INSTALLATION What s in the Box

icam7000s SERIES HARDWARE GUIDE Packing List CONTACTLESS CARD READER RECESS MOUNT (Optional) ISO/ANSI COMPLIANT EASY INSTALLATION What s in the Box icam7000s SERIES HARDWARE GUIDE ADVANCED MULTIFACTOR BIOMETRIC IRIS READER VERSION 1.0 icam7000s-t (Titanium Color) icam7000s-b (Black Color) DUAL IRIS ISO/ANSI COMPLIANT FACE CAMERA EASY INSTALLATION

More information

Installation Guide (ver 1.0)

Installation Guide (ver 1.0) IP based Fingerprint Access Control Installation Guide (ver 1.0) www.supremainc.com Contents Safety precautions 3 Basics of fingerprint recognition 5 How to place a finger 6 Product Contents 8 Front Side

More information

Lab 5: Access Control Training Station

Lab 5: Access Control Training Station Lab 5: Access Control Training Station Learning Objectives At the end of the lab, trainees should be able to: 1. Understand the functional block and hardware of an access control system. 2. Understand

More information

IP based Fingerprint Access Control. Installation Guide.

IP based Fingerprint Access Control. Installation Guide. IP based Fingerprint Access Control Installation Guide EN 101.00.BEP (ver V1.30 1.2) www.supremainc.com Contents Safety precautions 3 Basics of fingerprint recognition 5 How to place a finger 6 Product

More information

IPassan Installation guide

IPassan Installation guide IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...

More information

1. DB-9 interface pins Definition

1. DB-9 interface pins Definition 1 I. unction description II. Dry contact card is UPS options, which is used to provide UPS internal status to the outside or control peripheral device according to UPS status in the form of dry contact.

More information

DS-K2600 Series Access Controller. Quick Setup Guide. Ness V1.0

DS-K2600 Series Access Controller. Quick Setup Guide. Ness V1.0 DS-K2600 Series Access Controller Quick Setup Guide Ness V1.0 This is a Quick Setup Guide for Ness Version of Hikvision DS-K2604 4 Door Access Controllers. For full details refer Ness Full User Manual

More information

-DTZ001- Stand-Alone Proximity Access Control. User Manual

-DTZ001- Stand-Alone Proximity Access Control. User Manual -DTZ001- Stand-Alone Proximity Access Control User Manual INTRODUCTION DTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users,

More information

SCR100 User Manual. Version:1.1 Date:Dec 2009

SCR100 User Manual. Version:1.1 Date:Dec 2009 SCR100 User Manual Version:1.1 Date:Dec 2009 Introduction: This document mainly introduces the installations and connections of SCR100 products, and the brief operations about attendance software. Important

More information

Installation and User Manual

Installation and User Manual S2 Metal Waterproof Access Control Unit Installation and User Manual (Ness Part No. 101-082) 1 Introduction Ness S2 is an advanced, waterproof (IP65 rated) proximity and PIN Access Controller. S2 can support

More information

F11 Installation Guide. Version: 1.0 Date: Jul. 2010

F11 Installation Guide. Version: 1.0 Date: Jul. 2010 F11 Installation Guide Version: 1.0 Date: Jul. 2010 Table of Contents Table of Contents 1. Before Installing... 1 1.1 Notice About Installing... 1 1.2 Operation Panel:... 3 2. System Configuration...

More information

4. We recommend that you install the ievo reader at the DDA height of approximately 1 metre. This will be the perfect height for finger placement.

4. We recommend that you install the ievo reader at the DDA height of approximately 1 metre. This will be the perfect height for finger placement. WELCOME ievo would like to thank you for purchasing our product. This manual is designed to make your installation of our superior biometric reader quick, easy and efficient. Please ensure you check all

More information

Operation Manual. Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller

Operation Manual. Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller Operation Manual Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller KEYKING GROUP Index Chapter 1: Summay...3 1.1 Outline...3

More information

ACCESS CONTROL SYSTEM

ACCESS CONTROL SYSTEM ACCESS CONTROL SYSTEM System versions Standalone controllers series based on integrated models KZ-400, 500, 600, 700, KZC-300,800, 900 KaDe Lite system based on integrated controllers KZ-1000 KaDe Premium

More information

Amano Nexus Lite Controller INSTALLATION MANUAL

Amano Nexus Lite Controller INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power NEXUS LITE Amano Nexus Lite Controller INSTALLATION MANUAL MODEL NUMBER: ISC920-0-0-AC-XX ISC921-5-0-AC-XX Designed to work in an indoor (dry)

More information

Manual er under oversettelse til norsk.

Manual er under oversettelse til norsk. Manual er under oversettelse til norsk. Suprema Inc. 16F Parkview Office Tower, Jeongja-dong, Bundang-gu, Seongnam, Gyeonggi, 463-863 Korea E-mail : support@supremainc.com Website : www.supremainc.com

More information

DOLXFD1000B. Waterproof Access Control/Reader

DOLXFD1000B. Waterproof Access Control/Reader DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to

More information

Installation Instruction

Installation Instruction Installation Instruction Version: 3.1.1 Date: June 2010 About This Manual This document describes the installation guide and wiring instruction. Installation InstructionV3. 1.1 Contents 1. Before Installing...1

More information

Wireless Key fob, Key pad & Receiver Range

Wireless Key fob, Key pad & Receiver Range Wireless Key fob, Key pad & Receiver Range 4Ch Wireless Receiver 4x Voltage Free relay outputs (NO + NC) 100m Transmission range Multiple user codes 2 Channel wireless control Clear hinge up lid 12V DC

More information