LS 5000 series Vibration Level Switch for liquids

Size: px
Start display at page:

Download "LS 5000 series Vibration Level Switch for liquids"

Transcription

1 Vibration Level Switch for liquids Set-up without adjustment Integrated fault monitoring Unaffected by product variations in density, conductivity, dielectric constant or viscosity Insensitive to foam, pressure and temperatures variations Insensitive to external vibrations Operating temperature up to 250 C (optional) Status: 10/99

2 Vibration Level Switch for liquid Overfill or dry-run protection Suitable for applications in confined spaces (fork length only 40mm) Electronics replaceable under process conditions Operating Principle The tuning fork is piezoelectrically energised and vibrates at its mechanical resonance frequency of approx Hz. The piezoelectric elements are fastened mechanically and are therfore not subject to temperature shock limitations. When the tuning fork is immersed in the product, the frequency changes. This change is detected by the integrated oscillator and converted into a switching command. The models LS 5100 and LS 5150 are short versions without extension, whereas LS 5200 and LS 5250 can be ordered with extension tubes. The level switches LS 5150 and LS 5250 have a polished surface especially suitable for applications in hygienic industries. Housing Aluminium (plastic coated) plastic Process connection Thread G 3 /4 A, 3/4 NPT, G 1 A and 1 NPT Flanges from DN 25 or ANSI 1 Hygienic fittings LS 5200/5250 Electronics Non-contact switch Floating relay output Floating transistor output Two-wire current output Two-wire current output acc. to NAMUR LS 5100/5150 Tube extension up to 4000 mm length Tuning fork material Stainless steel (316L) also polished up to Ra 0,5 µm Hastelloy C4 (2.4610) ECTFE coated Enamelled 2

3 The responsibility as to the suitability, intended use and corrosion-resistance of the materials used in their construction rests solely with the purchaser. Technical data Process conditions Product temperature ( / Hastelloy C4) C ( F) Product temperature with temp. adapter of (option) LS 5000 series of / Hastelloy C C ( F) LS 5000 series enamelled C ( F) LS 5000 series ECTFE coated C ( F) Operating pressure max 64 bar (928 psi) Dep. on mechanical connection Product viscosity (dynamic) mpas Product density g/cm 3 Materials Housing PBT (Polyester), Aluminium (plastic coated) Tuning fork (316L) or (Hastelloy C4), Hastelloy C4 enamelled, with ECTFE coated Flanges , with Hastelloy C4 plated, enamelled steel, ECTFE coated Extension tube (316L) or (Hastelloy C4), Hastelloy C4 enamelled, with ECTFE coated Adapters Temperature adapter Gastight leadthrough (option) / glass (not ExD) Length Tuning fork 40 mm Extension tube (LS 5200 / 5250) Steeel , (Hastelloy C4) mm Hastelloy C4 enamelled mm ECTFE coated mm Surface quality (option) Standard (LS 5100 / 5200) Ra approx. 3.0 µm Polished (LS 5150 / 5250) Ra 1.5 µm Hygienic version (3A/FDA) (LS 5150 / 5250) Ra 0.5 µm Process connection Thread G 3 /4 A, 3 /4 NPT, G1A or 1 NPT PN 64 Flange DIN DN 25, ANSI 1 Hygienic fittings Bolting DN 40 PN 40 Tri-Clamp 1, 1 1 /2 PN 10 Cone DN 25 PN 40 Tuchenhagen Varivent DN 50 PN 10 Electronics SW E60N (EX) Supply For connection to separator acc. to NAMUR, approx. 8.2 V Open circuit voltage Approx. 8.2 V Short-circuit current Approx. 8.2 ma Output Two-wire NAMUR output Current consumption Characteristics falling 2.2 ma uncovered/ 1 ma covered Characteristics rising 1 ma uncovered/ 2.2 ma covered Fault signal 1 ma SW E60Z (EX) Supply voltage V DC (via signal conditioning instrument SU 501) Output Two-wire output Current consumption Approx. 8 ma empty/ approx. 16 ma full SW E60C,R,T (EX) Supply voltage V AC, 50/ 60 Hz or V DC Output Contactless electronic switch Internal current Requirement approx. 3 ma (via load circuit) Load current Min. 10 ma; max. 400 ma Protection class DIN IP 66 / IP 67 Approvals As overfill protection in conformity with WHG (Germany) Accessories Welding socket For thread of with O-ring in front, optionally with welding mark for defined fork alignment. 3

4 Mounting instructions Vertical installation from top, from bottom Horizontal installation Switching point Switching point with lower density Switching point approx. 13 mm Switching point with higher density Switching point recommended installation position for adhesive products: Switching point Top marking Vibrations Lateral load Extreme vibrations and shocks can cause the extension tube to vibrate. Therefore provide a fastening or straining directly above the tuning fork to fasten the extension tube. Make sure that the vibrating element is not subjected to lateral forces. Mount the instrument at a location in the vessel where no interfering effects can occur. The surface of the tuning fork should be parallel to the product movement. Moisture Turn the cable entries of horizontally mounted instruments downwards to avoid moisture ingress. For this purpose the plastic housing can be rotated by approx For vertically installed instruments, loop the cable connected to the instrument housing downwards so that rain and condensation water can drain off. Marking of welded socket Marking Thread starting point is defined. Remove therefore the supplied seal from the thread. This seal is not required when using a welded socket. Screw the level switch into the welded socket. The welded socket has a notch. Weld this socket with the notch facing upwards, or in the case of pipelines, aligned with the direction of flow. 4

5 Electrical connection Two-wire NAMUR output (SW E60N) SW E60N Ex Two-wire output (SW E60Z) SW E60Z Ex NAMUR (IEC ) + 0,5 g / cm V DC 0,5 g / cm ,7 g / cm ,7 g / cm Switching ampfifier acc. to NAMUR (IEC ) 1 A Contactless electrical switch (SW E60C) Floating realy output (SW E60R) SW E60C SW E60R + L V AC/DC max 400mA + L N N A 12 0,5 g / cm V DC V AC + L N A B 0,5 g / cm 3 0,7 g / cm B 0,7 g / cm Power supply: V AC, 50/60 Hz V DC (for further information, see installation manual) Power supply: V AC, 50/60 Hz V DC (for further information, see technical data) 1 2 5

6 Floating transistor output (SW E60T) V DC SW E60T PNP NPN + + out max 400mA A 0,5 g / cm 3 The responsibility as to the suitability, intended use and corrosion-resistance of the materials used in their construction rests solely with the purchaser. Power supply: V DC (for further information see the following connection examples as well as the technical data) B 0,7 g / cm 3 For direct control of relays, contactors, magnet valves, warning lights, horn, as well al PLC inputs Connection examples NPN action PNP action NPN action PNP action NPN action PNP action The transistor switches the supply voltage of the oscillator to the binary input of a PLC or to an electrical load. Trough different connection of the cunsumer (load). PNP or NPN action can be preset. Control of alternating current loads The transistor switches a second, galvanically isolated voltage source to the binary input of a PLC or to an electrical load. Trough different connection of the cunsumer (load). PNP or NPN action can be preset. The transistor switches a second voltage source with the same reference potential to the binary input of a PLC or to an electrical load. Trough different connection of the cunsumer (load). PNP or NPN action can be preset. The transistor switches a galvanically separated alternating voltage V AC to a load. 6

7 Dimensions LS 5000 series 7

8 Dimensions LS 5000 series 8

9 Dimensions LS 5000 series 9

10 Ordering Code LS 5100/5200 Vibrating level switch for liquids for LS 5100 for LS

11 Length of the extended probe for the LS 5200 only Total length in mm Length (L) mm (min. 150 mm; max mm) Table: Process Connection Type / Process Connection Size / Process Connection and fork material for LS 5100/

12 Ordering Code LS 5150/5250 Vibrating level switch for liquids and for hygienic applications Fork surface roughness : Ra < 1.5 µm or RA < 0.5 µm for LS 5150 for LS

13 Length of the extended probe for the LS 5250 only Total length in mm Length (L) mm (min. 150 mm; max mm) Table 1: Process Connection Type / Process Connection Size / Process Connection and fork material for LS 5150/

Operating Instruction

Operating Instruction Level and Pressure Operating Instruction VEGASWING 71 A Contents Contents Safety information... 2 1 Product description 1.1 Function and configuration... 3 1.2 Functional principle... 3 1.3 Technical data...

More information

OPTISWITCH 4000 C 5100 C, 5150 C 5200 C, 5250 C

OPTISWITCH 4000 C 5100 C, 5150 C 5200 C, 5250 C Level detection in liquids Vibration OPTISWITCH 4000 C 500 C, 550 C 500 C, 550 C Data Sheet Contents Contents Description of the measuring principle.... Type overview.... 6 Mounting information... 8 4

More information

Technical Data Sheet. OPTISWITCH 5000 series Vibration Level Switch. for liquids

Technical Data Sheet. OPTISWITCH 5000 series Vibration Level Switch. for liquids Technical Data Sheet KROHNE 01/2006 7.02395.26.00 CMD OPTISWITCH 5000 series Vibration Level Switch for liquids Integrated fault monitoring Unaffected by product variations in density, conductivity, dielectric

More information

Operating Instructions OPTISWITCH 5200 C, 5250 C with relay output

Operating Instructions OPTISWITCH 5200 C, 5250 C with relay output Operating Instructions OPTISWITCH 5200 C, 5250 C with relay output Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety 2.1 Authorised

More information

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free

More information

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES For liquids and solids NIVOSWITCH VIBRATING FORK LEVEL SWITCHES OUR PROFESSION IS YOUR LEVEL LEVEL SWITCHES O U R P R O F E S S I O N I S NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini

More information

Technical Data Sheet. OPTISWITCH 3000 series Vibration level switch. for solids

Technical Data Sheet. OPTISWITCH 3000 series Vibration level switch. for solids Technical Data Sheet KROHNE 04/2005 7.02541.21.00 GR OPTISWITCH 3000 series Vibration level switch for solids Highly robust tuning fork Insensitive to build-up Set-up without filling Detection of solids

More information

FOR LIQUIDS AND SOLIDS

FOR LIQUIDS AND SOLIDS FOR LIQUIDS AND SOLIDS LEVEL SWITCHES VIBRATING FORK LEVEL SWITCHES O U R P R O F E S S I O N NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini compact type Rod extension up to 3 meters (10

More information

Technical Data Sheet. OPTISWITCH 3000 series Vibration level switch. for solids

Technical Data Sheet. OPTISWITCH 3000 series Vibration level switch. for solids Technical Data Sheet KROHNE 04/2005 7.02541.21.00 GR OPTISWITCH 3000 series Vibration level switch for solids Highly robust tuning fork Insensitive to build-up Set-up without filling Detection of solids

More information

Liquiphant T FTL20. Technical Information. Level limit switch for liquids

Liquiphant T FTL20. Technical Information. Level limit switch for liquids Technical Information Liquiphant T FTL0 Level limit switch for liquids Application The Liquiphant T FTL0 is a level limit switch for all kinds of fluids and is used in tanks, containers and pipelines.

More information

Operating Instructions April 2008 SITRANS LVL200S

Operating Instructions April 2008 SITRANS LVL200S Operating Instructions April 2008 SITRANS LVL200S Content Content 1 About this document 1.1 Function............................. 4 1.2 Target group.......................... 4 1.3 Symbolism used.......................

More information

Operating Instructions April 2008 SITRANS LVL200E

Operating Instructions April 2008 SITRANS LVL200E Operating Instructions April 2008 SITRANS LVL200E Content Content 1 About this document 1.1 Function............................. 4 1.2 Target group.......................... 4 1.3 Symbolism used.......................

More information

Level. Conductive. Level detection. Overview Page 142 VEGAKON series 60 Page 144 EL 1 EL 8 Page 148 Limit switches VEGATOR Page 157

Level. Conductive. Level detection. Overview Page 142 VEGAKON series 60 Page 144 EL 1 EL 8 Page 148 Limit switches VEGATOR Page 157 Conductive Level detection Level Overview Page 142 VEGAKON series 60 Page 144 EL 1 EL 8 Page 148 Limit switches VEGATOR Page 157 141 VEGAKON Proven compact limit switches Measuring principle and applications

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Vibration. Level detection

Vibration. Level detection Vibration Level detection 5 Overview Page 116 VEGASWING 51 Page 120 VEGASWING series 60 Page 122 VEGAVIB series 60 Page 128 VEGAWAVE series 60 Page 134 Accessory Page 140 Level switches VEGATOR Page 144

More information

Capacitance level switches LS 210 LS 220

Capacitance level switches LS 210 LS 220 KROHNE 03/2001 7.02374.31.00 GR/PRINTO Capacitance level switches Compact switches for liquids, solids, slurry, foam and interface; outstanding performance for a low price Easy to install, no moving parts,

More information

Assembly. Function 41

Assembly. Function 41 Capacitive limit switch Features Assembly Limit switch for liquids and bulk solids Device with rod probe Complete unit consisting of the probe and electronic insert Integrated active build-up compensation:

More information

Magnetic float switch For vertical installation Model FLS

Magnetic float switch For vertical installation Model FLS Level measurement Magnetic float switch For vertical installation Model FLS WIKA data sheet LM 30.01 for further approvals see page 3 Applications Level measurement for almost all liquid media Pump and

More information

TECHNICAL INFORMATION Vibracon LVL-A7

TECHNICAL INFORMATION Vibracon LVL-A7 PROCESS AUTOMATION TECHNICAL INFORMATION Vibracon LVL-A7 Vibration Limit Switch Limit Switch for Liquids ISO900 With regard to the supply of products, the current issue of the following document is applicable:

More information

Float switch For the process industry

Float switch For the process industry Level measurement Float switch For the process industry Model FLS (models with E approval: 60, AL-ADF) KSR data sheet LM 30.01 for further approvals see page 3 Applications Level measurement for almost

More information

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids Technical Information Level limit switch for multiple point detection in conductive liquids Applications The Liquipoint T sensors are used in conductive liquids (down to 0 µs/cm) for determining level

More information

A TECHNOLOGY FOR EVERY LEVEL APPLICATION

A TECHNOLOGY FOR EVERY LEVEL APPLICATION INSTRUCTION MANUAL A TECHNOLOGY FOR EVERY LEVEL APPLICATION NIVOSWITCH R0/R500 VIBRATION FORK LEVEL SWITCHES Dual purpose level switch with intelligent electronics applicable for: almost all liquids light,

More information

Capacitive. Overview 116 VEGACAP series VEGACAP 27, 35, Capacitive VEGACAP

Capacitive. Overview 116 VEGACAP series VEGACAP 27, 35, Capacitive VEGACAP Capacitive Overview 116 VEGACAP series 60 120 VEGACAP 27, 35, 98 132 Capacitive VEGACAP 115 VEGACAP Level detection in bulk solids and liquids Measuring principle Sensor and vessel form the two electrodes

More information

Liquipoint T FTW31, FTW32

Liquipoint T FTW31, FTW32 TI00375F/00/EN/14.16 71336942 Products Solutions Services Technical Information Liquipoint T FTW31, FTW32 Conductive Point level switch for multiple point detection in conductive liquids Applications The

More information

LS 6600 Technical Datasheet

LS 6600 Technical Datasheet Technical Datasheet Switch for level detection and dry-run protection Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Small and compact KROHNE 06/2011-4001367301

More information

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing Vane wheel probe BFA25 for flow measurement of gases and liquids with egrated, configurable transducer UFA in Ex-d housing Drawing 5 Vane wheel flow probe BFA25 (Dimensions see Page 3) Measurable variables

More information

Technical Information Liquiphant FTL31

Technical Information Liquiphant FTL31 TI047F/00/EN/0.6 7589 Products Solutions Services Technical Information Liquiphant FTL Vibronic Point level switch for liquids Application The Liquiphant FTL is a point level switch for liquids and is

More information

Float Switches with Permanent Magnet For Horizontal Installation Model HIF

Float Switches with Permanent Magnet For Horizontal Installation Model HIF Level Measurement Float Switches with Permanent Magnet For Horizontal Installation Model HIF WIKA Data Sheet LM 30.02 Applications Level measurement for almost all liquid media Pump/level control Chemical

More information

OPTISWITCH 6600 C Technical Datasheet

OPTISWITCH 6600 C Technical Datasheet Technical Datasheet Microwave Level Switch for standard hygienic applications Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Small and compact KROHNE CONTENTS

More information

TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2

TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2 PROCESS AUTOMATION TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2 Vibration Limit Switch Limit Switch for Bulk Solids ISO9001 With regard to the supply of products, the current issue of the following document

More information

Temperature Measurement SITRANS TS300

Temperature Measurement SITRANS TS300 Siemens AG 018 For food, pharmaceuticals and biotechnology modular design Dimensional drawings Cable gland M1x1.5 for cable Ø 3... 6.5 (0.1... 0.6) Ø 60 (.36) Ø d = N + H 1 Ø 50.5 (1.99) U X H 1 N H Ø

More information

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous

More information

Level measurement. Applications. Special features. Description

Level measurement. Applications. Special features. Description Level measurement Optoelectronic level switch Model OLS-S, for the process industry (with Ex i approval: KSR-OPTO.21*06XX) Model OSA-S, switching amplifier (with Ex i approval: KSR-OPTO.2502.XX) KSR data

More information

Level measurement CleverLevel LBFI Point level detection

Level measurement CleverLevel LBFI Point level detection User Product benefits highlights Safe detection of liquids, bulk solids and powders Short immersion length Capable of differentiation between foam and liquid Insensitive to adherent or sticky media Status

More information

Technical Information Liquipoint FTW23

Technical Information Liquipoint FTW23 TI0202F/00/EN/04.6 736230 Products Solutions Services Technical Information Capacitance point level measurement Point level switch for liquids in the food and beverage industry Application The is a point

More information

Level measurement CleverLevel LBFH Point level detection

Level measurement CleverLevel LBFH Point level detection Product highlights User benefi ts Safe detection of liquids, bulk solids and powders Short immersion length Ecellent cleanability Capable of differentiation between foam and liquid Insensitive to adherent

More information

Assembly. Connection FEL 52 (E5) 3-wire DC connection (example) FEL 52 (E5) 0.5 A U V DC V DC

Assembly. Connection FEL 52 (E5) 3-wire DC connection (example) FEL 52 (E5) 0.5 A U V DC V DC Vibration Limit Switch Features Assembly Level limit switch for liquids Large selection of process connections: universal use Wide variety of electronic modules (e. g., relay, thyristor signal output):

More information

Level sensor for monitoring the level of liquid media

Level sensor for monitoring the level of liquid media Level sensor MG Level sensor for monitoring the level of liquid media Characteristics Level sensor output 4 20mA or Resistance output in three-wire potentiometer circuit Temperature range: -30 C to 150

More information

Technical Information Liquipoint FTW33

Technical Information Liquipoint FTW33 TI008F/00/EN/0.5 78677 Products Solutions Services Technical Information Liquipoint FTW Conductive and capacitance point level measurement Point level switch for liquid and pasty media in the food and

More information

Level sensor with reed measuring chain Model FLR, for the process industry

Level sensor with reed measuring chain Model FLR, for the process industry Level measurement Level sensor with reed measuring chain Model FLR, for the process industry WIKA data sheet LM 20.02 for further approvals see page 3 Applications Level measurement for almost all liquid

More information

Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H

Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H Level measurement Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H KSR data sheet FFG-P, FFG-T, FFG-TP, FLM-H Applications High-accuracy level measurement

More information

Rosemount 2110 Compact Vibrating Fork Liquid Level Switch

Rosemount 2110 Compact Vibrating Fork Liquid Level Switch Product Data Sheet Rosemount 2110 Rosemount 2110 Compact Vibrating Fork Liquid Level Switch Function virtually unaffected by flow, turbulence, bubbles, foam, vibration, solids content, coating, properties

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

Level measurement CleverLevel LBFI Point level detection

Level measurement CleverLevel LBFI Point level detection Product highlights User benefi ts Safe detection of liquids, bulk solids and powders Short immersion length Capable of differentiation between foam and liquid Insensitive to adherent or sticky media Status

More information

Level switch NS 10/NS 25..-AM

Level switch NS 10/NS 25..-AM Level switch NS 10/NS 25..-AM Fluidcontrol Oil tanks in lubrication and oil supply systems are often under overpressure compared to the ambient atmosphere. All oil moistened parts of devices mounted externally

More information

Temperature Switches

Temperature Switches ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,

More information

Pressure transmitter/pressure switch PASCAL CS

Pressure transmitter/pressure switch PASCAL CS Pressure transmitter/pressure switch PASCAL CS for food/pharmaceutical/biotechnology,type series CS2110 Features Multifunctional pressure transmitter/pressure switch Hygienic case with no notches or indentations

More information

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Level sensor Stainless steel version Model RLT-1000, for industrial applications Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring

More information

Float switch For the process industry, lateral installation with external chamber Model ELS

Float switch For the process industry, lateral installation with external chamber Model ELS Level measurement Float switch For the process industry, lateral installation with external chamber Model ELS KSR data sheet LM 30.03 for further approvals see page 2 Applications Mounting on engines,

More information

Soliphant M FTM50, FTM51, FTM52

Soliphant M FTM50, FTM51, FTM52 Technical Information Soliphant M FTM50, FTM51, FTM52 Level limit switch Universal vibration limit switch for powder and fine-grained bulk solids, also for explosion-hazardous areas Application The Soliphant

More information

Technical Information Minicap FTC260, FTC262

Technical Information Minicap FTC260, FTC262 TI00287F/00/EN/16.16 71312209 Products Solutions Services Technical Information Minicap FTC260, FTC262 Capacitive Point level switch with buildup compensation No calibration necessary Application The Minicap

More information

FlexBar HRT Pressure Transmitter

FlexBar HRT Pressure Transmitter FlexBar HRT Pressure Transmitter 4...0 ma, -wire transmitter, HART communication Some hygienic connections conform to -A standards, FDA demands and EHEDG guidelines Configurable span, unit and damping

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Gladiator. Vibration Smart Switch Series. Data Sheet. A Higher Level of Performance. A level switch for liquids and solids.

Gladiator. Vibration Smart Switch Series. Data Sheet. A Higher Level of Performance. A level switch for liquids and solids. A Higher Level of Performance Data Sheet Gladiator Vibration Smart Switch Series A level switch for liquids and solids For more information, please visit > www.hawkmeasure.com Overview The Gladiator Smart

More information

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers Product highlights 3-A fulfillment without elastomers Front-flush or immersed types Accurate reading independent on ambient temperature Fast response time Hermetically sealed towards process Capable of

More information

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage. Guided Level Radar Features Measurement independent of density, temperature, and dust Measurement also possible with foam on the surface Simple, menu-guided on-site operation with four-line plain text

More information

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Material pressure (bar) (Cv (US) kv x 1,2 Seat 00 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V Valves for safety systems up to SIL Solenoid valve also

More information

Electronic pressure switch with display For sanitary applications Model PSA-31

Electronic pressure switch with display For sanitary applications Model PSA-31 Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling

More information

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456 Supplementary instructions Plug connector Harting HAN 7D For point level sensors Document ID: 446 Contents Contents For your safety.... Appropriate use.... General safety instructions.... Safety instructions

More information

Installation Instructions Temperature transmitter TAA /00 06/2011

Installation Instructions Temperature transmitter TAA /00 06/2011 Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to

More information

02/11/2015

02/11/2015 DIN Rail Mount 35 mm HSV Part number 84874320 Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact

More information

Capacitive Limit Detection minicap FTC 260, FTC 262

Capacitive Limit Detection minicap FTC 260, FTC 262 Technical Information TI 287F/00/en Capacitive Limit Detection minicap FTC 260, FTC 262 Compact switch for limit detection with active build-up compensation No calibration necessary Version available for

More information

selection of special materials is available to handle almost any fluid.

selection of special materials is available to handle almost any fluid. For Pressure Transmitters and Bourdon Tube Pressure Gauges Types 839 X Chemical Seals for Various Applications Advantages / Benefits Separation of medium and measuring device in difficult applications

More information

Series 100. Mechanical Switches Contents. Series 100 Multiple Position Switches

Series 100. Mechanical Switches Contents. Series 100 Multiple Position Switches Contents Series 00 Multiple Position Switches Full size housing Full size switch elements DIN 43697 Up to 2 positions IO-Link Quick change plunger block Inductive Inductive with extended range 2 or 6 mm

More information

Installation, Operation & Maintenance Instructions / Technical Document

Installation, Operation & Maintenance Instructions / Technical Document Installation, Operation & Maintenance Instructions / Technical Document Model VHL Mini Vibrating Fork Point Level Sensor for Liquids Thank you for purchasing the Model VHL Mini Vibrating Fork Point Level

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

Flow measurement FlexFlow PF20S Flow sensor for industrial applications Product highlights Parallel measurement of flow and temperature Flow measurement independent of the mounting position Large measuring range up to 400 cm/s Measurement at high media temperatures up to 125

More information

Pressure transmitter/pressure switch PASCAL CS

Pressure transmitter/pressure switch PASCAL CS Pressure transmitter/pressure switch PASCAL CS for food/pharmaceutical/biotechnology, Type series CS2110 Features Multifunctional pressure transmitter/pressure switch Hygienic case with no notches or indentations

More information

Faults on the system Proximity switch connection technology:

Faults on the system Proximity switch connection technology: Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP Safety-Lock TM High rotational speed Temperature High IP High shaft load capacity Shock/vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection Reliable Increased ability

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Multiturn absolute encoder

Multiturn absolute encoder Release date: 207-0-2 :0 Date of issue: 207-0-2 t79_eng.xml Model Number Features Industrial standard housing Ø58 mm PROFINET IRT 0 Bit multiturn Servo or clamping flange Network loop through by means

More information

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits RHM160 Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications Features Standard Pressure ratings up to 50bar (725 psi) Temperature ratings from -196 to 120 C (-320 to 248 F) Mass flow

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Contact Dial Thermometers

Contact Dial Thermometers Data sheet 6852 Page 1/11 Contact Dial Thermometers FL 21 Special features Class 1.5 Display range -4 C to +6 C Temperature controller with actual value display as built-in or add-on device in a stainless

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

Level gauges Series LS Level indicator, switch and transmitter for liquids

Level gauges Series LS Level indicator, switch and transmitter for liquids Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm

More information

SM9000. Magnetic-inductive flow meter. Made in Germany

SM9000. Magnetic-inductive flow meter. Made in Germany Made in Germany Application Application totaliser function; empty pipe detection; for industrial applications Installation connection to pipe by means of an adapter Media conductive liquids; water; hydrous

More information

... f l o w measurement & control...

... f l o w measurement & control... ... f l o w measurement & control... ELECTROMAGNETIC FLOWMETERS OPEN CHANNEL MAGNETIC FLOWMETER PARTLY FILLED PIPE MAGNETIC FLOWMETER VENTURI & PARSHALL FLUMES ULTRASONIC LEVEL MEASUREMENT ULTRASONIC OPEN

More information

Variable Area Flowmeters Installation Instructions G Series and M Series

Variable Area Flowmeters Installation Instructions G Series and M Series Variable Area Flowmeters Installation Instructions G Series and M Series Safety Definitions Potential danger to life or of serious injuries. Potential for personal injury from electrical shock. Safety

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

SM9000. Made in Germany

SM9000. Made in Germany Made in Germany Product characteristics Magnetic-inductive flow meter Connector Process connection: G2 flat seal connection to pipe by means of an adapter Function programmable Totaliser function Empty

More information

Operating Instructions for Level Switch for Liquids. Model: RFS

Operating Instructions for Level Switch for Liquids. Model: RFS Operating Instructions for Level Switch for Liquids Model: RFS 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Use in Hazardous

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

MANUAL Vibracon LVL-A7

MANUAL Vibracon LVL-A7 PROCESS AUTOMATION MANUAL Vibracon LVL-A7 Vibration Limit Switch Limit Switch for Liquids ISO900 With regard to the supply of products, the current issue of the following document is applicable: The General

More information

Electronic pressure switch with display For sanitary applications Model PSA-31

Electronic pressure switch with display For sanitary applications Model PSA-31 Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling

More information

MPreC - Pressure Relief Device Order specification sheet

MPreC - Pressure Relief Device Order specification sheet - Pressure Relief Device Order specification sheet -Series LARGE MESSKO PRESSURE RELIEF DEVICE Complete the Order-N o by choosing the specific add-on s: e.g.: LMPRD 685-08-22-N01-00 Order-N o : Parameter

More information

Immersion Temperature Sensors

Immersion Temperature Sensors 1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or

More information

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0 monitoring in conductive liquids 4 probe inputs for level monitoring Multifunction Adjustable sensor voltage Supply voltage 24-240V AC/DC Protective separation of measuring circuit 3 normally open contacts

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M low sensor MAG P Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

General Specifications

General Specifications General Specifications Model RAGH Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. The mounting position is

More information

Gladiator. Vibration Smart Switch Series. Data Sheet. Overview. A Higher Level of Performance. A level switch for liquids and solids

Gladiator. Vibration Smart Switch Series. Data Sheet. Overview. A Higher Level of Performance. A level switch for liquids and solids Gladiator Admittance Smart Switch Series A Higher Level of Performance Data Sheet Gladiator Vibration Smart Switch Series A level switch for liquids and solids For more information, please visit > www.hawkmeasure.com

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor.   Operating Instructions: EN. EN/2017-04-03 Design and specifications subject to change without notice English page 1 8 Field of application CombiTemp TFRx is a temperature sensor, based on RTD technology, which is designed and produced

More information

C-Flow Coriolis Mass Flow Meter

C-Flow Coriolis Mass Flow Meter Coriolis Mass Flow Meter Application and Features For fluids (e.g. PU components, paints) and gases of high density Suitable for aggressive and contaminated media Measurement of mass flow, density, temperature

More information