Float Switches with Permanent Magnet For Vertical Installation Model RSM

Size: px
Start display at page:

Download "Float Switches with Permanent Magnet For Vertical Installation Model RSM"

Transcription

1 Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM Applications Level measurement for almost all liquid media Pump/level control and monitoring for defined filling levels Chemical industry, petrochemical industry, natural gas, offshore, shipbuilding, machine building, power generating equipment, power stations Process water and drinking water treatment, food and beverage industry Special Features Large scope of application due to the simple, proven functional principle For harsh operating conditions, long service life Operating limits: - Operating temperature: T = C - Working pressure: P = vacuum to 100 bar - Limit S. G.: ρ 400 kg/m 3 Wide variety of different electrical connections, process connections and materials Explosion-protected versions Description A float with a permanent magnet moves reliably along with the liquid level on a guide tube. Within the guide tube is fitted a reed contact (inert gas contact), which is energised, through the non-magnetic walls of the float and guide tube, by the approach of the float magnet. By using a magnet and reed contact the switching operation is non-contact, free from wear and needs no power supply. The contacts are potential-free. WIKA float switches with permanent magnets are also available with several switch points. Float Switches with Permanent Magnet, for vertical installation, Model RSM Fig. left: Stainless steel version, mounting thread Fig. right: Plastic version, flange connection The switch functions always refer to a rising liquid level: normally open / normally closed / change-over contacts. Through the use of a float for a max. of switch points a bistable switch operation can be achieved, meaning that the switching status also remains available, when the filling level continues to rise above or drop below the switch point. The float switch is simple to mount and maintenance-free, so the costs of mounting, coissioning and operation are low. WIKA Data Sheet LM /010 Page 1 of 14 Data Sheets showing similar devices: Float Switches with Permanent Magnet, horizontal installation; Model HIF; see data sheet LM 30.0 Float Switches with Permanent Magnet, lateral mounting; Model RSB; see data sheet LM 30.03

2 Further special features Process connection, guide tube material and float made of stainless steel or plastic Universal signal processing: connection direct to a PLC is possible, NAMUR connection, signal amplification / contact protection relays Works independently of foaming, conductivity, dielectricity, pressure, vacuum, temperature, steam, condensation, blistering, boiling effects and vibrations Multiple functionality in a single instrument - up to 8 potential-free contacts Exact repeatability of the switch points Float switches with permanent magnets qualify as passive electrical equipment in accordance with DIN IEC and can be installed in 'Zone 1' hazardous areas without certification, so long as the equipment is operated in a certified intrinsically safe circuit with a minimum explosion protection of EEx ib Options Customer-specific solutions Specific designs for interface layer detection -ρ 50 kg / m 3 Process connection, guide tube material and float made of stainless steel , , titanium, Hastelloy (others on request) Page of 14 WIKA Data Sheet LM /010

3 Application examples Level switch (EEx i) Intrinsically safe Intrinsically safe Intrinsically safe relay e.g.: KR 4 Ex Intrinsically safe relay e.g.: KR 4 Ex Ex zone non Ex zone Ex zone non Ex zone Level control (min.-max. control) Contact protection relay e.g.: KR 30 Contact protection relay e.g.: KR 4 Product prograe Selection of process connection, material and design further information on the indicated pages. Process connection Material Explosion-protected Material Stainless steel version PVC / PP / PVDF (without terminal box) G 1/8"... G " Page 4 Page 5 (adjustable guide tube) Page 7 (Mini float) - Page 8 G 1/"... G " Page 4 Page 5 (adjustable guide tube) Page 7 (Mini float) Page 6 Page 8 Flange DN DN 00 PN 6... PN 100 Page 4 Page 5 (adjustable guide tube) Page 9 (E-CTFE coated) Page 6 Page 8 Float versions: page 10 and 11 Contact protection measures: page 1 Connection diagrams: page 13 and 14 WIKA Data Sheet LM /010 Page 3 of 14

4 Standard version Process connection, guide tube material and float made of stainless steel Connection cable (without terminal box) Flange Electrical connection Process connection Connection cable PVC grey PVC blue Silicone PUR upwards G 3/8" (others on request) G 1/" (others on request) downwards G 1 1/" or G " Aluminium 64 x 58 x 34, with 1 contact Aluminium 80 x 75 x 57, or more contacts Option: Polypropylene, polyester, stainless steel Mounting flange DIN DN DN 00, PN 6... PN 100 ANSI "... 8", Class Guide tube diameter 1 or or or Guide tube length L max Float Temperature range standard Material stainless steel (Option: Buna, titanium) Float diameter from Float selection depending on guide tube diameter and process conditions (see page 10 and 11) PVC / PUR cable C Silicone cable C C Option: High temperature version: C Option: Low temperature version: C Switch function Max. number of contacts Switch position Distance between switch points Optionally contact makes S, contact breaks O or change-over U - at increasing level PVC cable 6 x S or O, or 4 x U Silicone cable 5 x S or O, or 3 x U 6 x S or O, or 4 x U Dimensions L 1, L, L 3... (from sealing face, starting from top) Minimum 0 (depending on the selection of the float and the contacts, see page 10 and 11) Contact rating Contact makes 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Contact breaks 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 30 V AC; 40 VA; 1 A 30 V DC; 0 W; 0.5 A Mounting position Vertical ± 30 Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Ingress protection IP 65 per EN / lec 59 Page 4 of 14 WIKA Data Sheet LM /010

5 Version with adjustable guide tube Process connection, guide tube material and float made of stainless steel guide tube adjustable by loosening union nut Connection cable 7 flats guide tube adjustable by loosening union nut 7 flats guide tube adjustable by loosening union nut 7 flats 14 G 1/" (without terminal box) Flange Electrical connection Process connection Guide tube diameter Guide tube length L max. Float Nominal pressure Temperature range standard Switch function Max. number of contacts Switch position Distance between switch points Connection cable PVC grey PVC blue Silicone PUR upwards G 1/" (others on request) Aluminium 64 x 58 x 34, with 1 contact Aluminium 80 x 75 x 57, or more contacts Option: Polypropylene, polyester, stainless steel downwards G 1 1/" or G " (others on request) Material stainless steel (Option: Buna, titanium) Float diameter from Float selection depending on guide tube diameter and process conditions (see page 10 and 11) 5 bar PVC / PUR cable C Silicone cable C C Optionally contact makes S, contact breaks O or change-over U - at increasing level PVC cable 6 x S or O, or 4 x U Silicone cable 5 x S or O, or 3 x U 6 x S or O, resp. 4 x U Dimensions L 1, L, L 3... (from sealing face, starting from top) Minimum 0 (depending on the selection of the float and the contacts, see page 10 and 11) Mounting flange DIN DN DN 00, PN 6... PN 100 ANSI "... 8", Class Contact rating Contact makes 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Contact breaks 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 30 V AC; 40 VA; 1 A 30 V DC; 0 W; 0.5 A Mounting position Vertical ± 30 Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Ingress protection IP 54 per EN / lec 59 IP 65 per EN / lec 59 WIKA Data Sheet LM /010 Page 5 of 14

6 Explosion-protected version, intrinsically safe II 1/G EEx ia IIC T3-T6 KEMA 09 ATEX 018X II D T80 C IP6X Process connection, guide tube material and float made of stainless steel X X Process temperature Raised terminal box X < 60 C 0 < 135 C 60 < 180 C 80 Flange Electrical connection Aluminium 80 x 75 x 57 Option: Polyester, stainless steel Process connection downwards G 1 1/" or G " (others on request) Mounting flange DIN DN DN 150, PN 6... PN 64 ANSI "... 6", Class Guide tube diameter 1 or or Guide tube length L max Float Temperature class Process temperature Ambient temperature at terminal box Material stainless steel (Option: Buna, titanium) Float diameter from Float selection depending on guide tube diameter and process conditions (see page 10 and 11) T3 T4 T5 T6 Max. 180 C 130 C 95 C 80 C Max. 60 C 60 C 60 C 60 C Switch function Max. number of contacts Switch position Distance between switch points Contact rating Optionally contact makes S, contact breaks O or change-over U - at increasing level 6 x S or O, or 4 x U Dimensions L 1, L, L 3... (from sealing face, starting from top) Minimum 0 (depending on the selection of the float and the contacts, see page 10 and 11) Only for connection to a certified intrinsically safe circuit with U max 36 V, I max 100 ma Mounting position Vertical ± 30 Ingress protection IP 65 per EN / lec 59 Options Temperature resistance Pt100 or Pt1000 Bimetal thermal contact C (in 5 degree steps) Page 6 of 14 WIKA Data Sheet LM /010

7 Mini float version Process connection and guide tube material made of stainless steel Coupler connector ASC4 M1 x 1 Connection cable 1 G 1/8" 7 flats (without terminal box) Electrical connection Connection cable PVC grey PVC blue Silicone PUR Aluminium 64 x 58 x 34 Coupler connector ASC4, C F-4P Coupler connector M1 x 1 Process connection upwards G 1/8" (others on request) downwards oder G 1" (others on request) Guide tube diameter 8 Guide tube length L max. 500 Float Temperature range Switch function Max. number of contacts Material stainless steel (Option: Buna, polypropylene, titanium) Float diameter from Float selection depending on guide tube diameter and process conditions (see page 10 and 11) C (Float material stainless steel or titanium) C (Float material Buna or polypropylene) Optionally contact makes S, contact breaks O or change over U - at increasing level 3 x S or O, or 1 x U Contact rating Contact makes 50 V AC; 10 VA; 0.5 A 50 V DC; 5 W; 0.5 A Contact breaks 50 V AC; 10 VA; 0.5 A 50 V DC; 5 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 8 V AC; 6 VA; 0.6 A 8 V DC; 3 W; 0.3 A Mounting position Vertical ± 30 Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Ingress protection IP 54 per EN / lec 59 IP 65 per EN / lec 59 WIKA Data Sheet LM /010 Page 7 of 14

8 Plastic version Process connection, guide tube material and float made of PVC, polypropylene or PVDF Guide tube Ø 1 Connection cable 1 G 3/8" flats M0 x 1.5 M0 x 1.5 Guide tube Ø 16 Connection cable 14 G 1/" 7 flats Guide tube Ø 0 Connection cable 4 G 1" 3 flats (without terminal box) Flange Electrical connection Process connection Guide tube diameter Guide tube length L max. Connection cable PVC grey PVC blue PUR, upwards G 3/8" (Guide tube Ø 1 ) G 1/" (Guide tube Ø 16 ) G 1" (Guide tube Ø 0 ) (others on request) Polypropylene 80 x 8 x 55, downwards G 1 1/" or G " (others on request) 1, 16 or 0 (16 and 0 : strengthened with a metallic inner tube) 500 (Guide tube Ø 1 ) 3000 (Guide tube Ø 16 ) 5000 (Guide tube Ø 0 ) Mounting flange DIN DN DN 15, PN 10, Form A ANSI "... 5", Class 150 FF Float Material PVC Polypropylene PVDF Float diameter from Float selection depending on guide tube diameter and process conditions (see page 11) Temperature range PVC C Polypropylene C PVDF C Switch function Optionally contact makes S, contact breaks O or change-over U - at increasing level Max. number of 4 x S or O (PP max. 3) resp. 3 x U (PP max. ) contacts Switch position Dimensions L 1, L, L 3... (from sealing face, starting from top) Distance between Minimum 0 (depending on the selection of the float and the contacts, see page 11) switch points Contact rating Contact makes 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Contact breaks 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 30 V AC; 40 VA; 1 A 30 V DC; 0 W; 0.5 A Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Mounting position Vertical ± 30 Ingress protection IP 54 per EN / lec 59 IP 65 per EN / lec 59 Page 8 of 14 WIKA Data Sheet LM /010

9 Stainless steel version, E-CTFE coated Process connection, guide tube material and float made of stainless steel , E-CTFE coated Flange (Guide tube diameter 1 ) Flange (Guide tube diameter 18 ) Electrical connection Aluminium 64 x 58 x 34, with 1 contact Aluminium 80 x 75 x 57, or more contacts Option: Polypropylene, polyester, stainless steel Process connections Mounting flange DIN DN DN 00, PN 6... PN 40 ANSI "... 8", Class Guide tube diameter 1 18 Guide tube length L max Float Temperature range Switch function Max. number of contacts Switch position Distance between switch points Material stainless steel (E-CTFE coated) Float diameter from Float selection depending on guide tube diameter and process conditions (see page 10) Depending on medium Optionally contact makes S, contact breaks O or change-over U - at increasing level 3 x S or O, resp. x U Dimensions L 1, L, L 3... (from sealing face, starting from top) Minimum 0 (depending on the selection of the float and the contacts, see page 10) Contact rating Contact makes 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Contact breaks 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 30 V AC; 40 VA; 1 A 30 V DC; 0 W; 0.5 A Mounting position Vertical ± 30 Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Ingress protection IP 65 per EN / lec 59 WIKA Data Sheet LM /010 Page 9 of 14

10 Spherical floats (K) Ø C D E B D = Limit S. G. of the medium iersed float volume 85 % E = Nominal S. G. of the medium iersed float volume 50 % Ø A Material Suits guide tube Ø Ø A B Ø C Max. working pressure bar Max. operating temperature C Limit S. G. 85 % kg/m 3 Nominal S. G. 50 % kg/m 3 Stainless steel Titanium Stainless steel depending on medium E-CTFE coated depending on medium depending on medium depending on medium depending on medium depending on medium depending on medium Note: The optimum float will be selected after a feasibility test carried out by WIKA. Page 10 of 14 WIKA Data Sheet LM /010

11 Cylindrical floats (Z) Ø C D E B D = Limit S. G. of the medium iersed float volume 85 % E = Nominal S. G. of the medium iersed float volume 50 % Ø A Material Suits guide tube Ø Ø A B Ø C Max. working pressure bar Max. operating temperature C Limit S. G. 85 % kg/m 3 Nominal S. G. 50 % kg/m 3 Stainless steel Titanium Buna PVC Polypropylene PVDF Stainless steel E-CTFE coated depending on medium Note: The optimum float will be selected after a feasibility test carried out by WIKA. WIKA Data Sheet LM /010 Page 11 of 14

12 Contact protection measures To ensure reliable operation of sensors with reed switches and highest possible service life, we recoend using one of the following circuits. Inductive load AC S1 Surge current measurement with oscilloscope S1 C R E 4-30V AC R C RC modules depending on operating voltage see table Example: C = 0.33 µf/4 V DC 4 V DC R M Inductive load DC V DC S1 Shunt diode e.g. 1N4007 I (A) without current limitation with current limitation not allowed allowed Current limitation with capacitive load e.g. PLC, DCS and cables > 50 m Protective RC modules t (? µ s) + 4 V DC S1 R S C 1 SPS Rs = Ohm (47 Ohm with 0 VA contacts) C 1 = internal capacitance RC modules are, depending on the operating voltage, to be used exclusively according to the table below. D L D = Ø 16 - Ø 5 L = 6-58 Current limitation with electronic timers 00 wire + 30 V AC S1 R S C 1 time Zeitrelais relay Rs = 0 Ohm (30 V AC) C 1 = internal capacitance For inert gas contacts from VA Capacitance Resistance Voltage 0.33 µf 100 Ohm 4 V AC 0.33 µf 0 Ohm 48 V AC 0.33 µf 470 Ohm 115 V AC 0.33 µf 1500 Ohm 30 V AC For inert gas contacts from VA Capacitance Resistance Voltage 0.33 µf 47 Ohm 4 V AC 0.33 µf 100 Ohm 48 V AC 0.33 µf 470 Ohm 115 V AC 0.33 µf 1000 Ohm 30 V AC Other types than the RC modules specified here might lead to destruction of the reed contact. Page 1 of 14 WIKA Data Sheet LM /010

13 Connection diagrams Colour coding per IEC 757 PVC cable Silicone cable Contact makes or breaks Change-over Contact makes or breaks Change-over Contact makes or breaks Change-over switch points 3 switch points 4 switch points L4 5 switch points VT L4 L5 switch points 3 switch points / 4 switch points / VT / L4 switch points 3 switch points switch points 1 switch points switch points switch points L4 8 5 switch points L4 8 VT 9 L5 CLEAR switch points switch points 1 OG switch points 1 OG VT 11 L4 CLEAR 1 6 switch points 6 switch points / / VT L4 L5 L VT 9 CLEAR OG 1 L4 L5 L6 WIKA Data Sheet LM /010 Page 13 of 14

14 Connection diagrams Colour coding per IEC 757 Coupler connector ASC4 Coupler connector M1 Contact makes or breaks Change-over switch points PE 1 4 Float switches with thermal contacts PVC or silicone cable or terminal box PVC cable Silicone cable or terminal box PVC or silicone cable or terminal box PVC cable 1 Thermal contact Thermal contacts Thermal contacts 1 Thermal contact Thermal contacts Thermal contacts ϑ ϑ 55 C ϑ 75 C ϑ 55 C ϑ 75 C ϑ / ϑ 55 C ϑ 75 C 1 OG ϑ 55 C ϑ 75 C Coupler connector ASC4 Coupler connector M1 Coupler connector M1 1 Thermal contact 1 3 ϑ 1 Thermal contact ϑ 1 Thermal contact ϑ Ordering information Model / Version / Electrical connection / Process connection / Guide tube diameter / Guide tube length L / Information about contact (switch function, number of switch points, switch position) / Process details (operating temperature and pressure, Limit S. G.) / Options Modifications may take place and materials specified may be replaced by others without prior notice. Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Page 14 of 14 WIKA Data Sheet LM /010 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße Klingenberg/Germany Tel. (+49) 937/13-0 Fax (+49) 937/ info@wika.de 01/010 GB

Float Switches with Permanent Magnet For Horizontal Installation Model HIF

Float Switches with Permanent Magnet For Horizontal Installation Model HIF Level Measurement Float Switches with Permanent Magnet For Horizontal Installation Model HIF WIKA Data Sheet LM 30.02 Applications Level measurement for almost all liquid media Pump/level control Chemical

More information

Magnetic float switch For vertical installation Model FLS

Magnetic float switch For vertical installation Model FLS Level measurement Magnetic float switch For vertical installation Model FLS WIKA data sheet LM 30.01 for further approvals see page 3 Applications Level measurement for almost all liquid media Pump and

More information

Float switch For the process industry

Float switch For the process industry Level measurement Float switch For the process industry Model FLS (models with E approval: 60, AL-ADF) KSR data sheet LM 30.01 for further approvals see page 3 Applications Level measurement for almost

More information

Float switch For the process industry, lateral installation with external chamber Model ELS

Float switch For the process industry, lateral installation with external chamber Model ELS Level measurement Float switch For the process industry, lateral installation with external chamber Model ELS KSR data sheet LM 30.03 for further approvals see page 2 Applications Mounting on engines,

More information

Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H

Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H Level measurement Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H KSR data sheet FFG-P, FFG-T, FFG-TP, FLM-H Applications High-accuracy level measurement

More information

Level sensor with reed measuring chain Model FLR, for the process industry

Level sensor with reed measuring chain Model FLR, for the process industry Level measurement Level sensor with reed measuring chain Model FLR, for the process industry WIKA data sheet LM 20.02 for further approvals see page 3 Applications Level measurement for almost all liquid

More information

Float switch For industrial applications Model RLS-1000

Float switch For industrial applications Model RLS-1000 Level measurement Float switch For industrial applications Model RLS-000 WIKA data sheet LM 50.0 Applications Level measurement of liquids in machine building Control and monitoring tasks for hydraulic

More information

Level sensor for monitoring the level of liquid media

Level sensor for monitoring the level of liquid media Level sensor MG Level sensor for monitoring the level of liquid media Characteristics Level sensor output 4 20mA or Resistance output in three-wire potentiometer circuit Temperature range: -30 C to 150

More information

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Level sensor Stainless steel version Model RLT-1000, for industrial applications Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring

More information

Reed sensor For bypass level indicators Model BLR

Reed sensor For bypass level indicators Model BLR Level measurement Reed sensor For bypass level indicators Model BLR WIKA data sheet LM 10.04 for further approvals see page 3 Applications Sensor for the continuous level measurement of liquids in bypass

More information

Level measurement. Applications. Special features. Description

Level measurement. Applications. Special features. Description Level measurement Optoelectronic level switch Model OLS-S, for the process industry (with Ex i approval: KSR-OPTO.21*06XX) Model OSA-S, switching amplifier (with Ex i approval: KSR-OPTO.2502.XX) KSR data

More information

Gas-actuated thermometer Stainless steel version Model 73

Gas-actuated thermometer Stainless steel version Model 73 Temperature Gas-actuated thermometer Stainless steel version Model 73 WIKA data sheet TM 73.01 for further approvals see page 15 Applications General process instrumentation in the chemical and petrochemical

More information

Thermocouples Model TC200, for Additional Thermowell

Thermocouples Model TC200, for Additional Thermowell Electrical Temperature Measurement Thermocouples Model TC200, for Additional Thermowell WIKA Data Sheet TE 65.10 Applications T Machinery, plant and tank construction T Energy and power plant technology

More information

Resistance thermometer With spring-loaded tip Model TR55

Resistance thermometer With spring-loaded tip Model TR55 Temperature Resistance thermometer With spring-loaded tip Model TR55 WIKA data sheet TE 60.55 for further approvals see page 2 Applications Bearing temperature measurement on: Pumps Gears Motors Special

More information

Threaded resistance thermometer Miniature design Model TR10-D

Threaded resistance thermometer Miniature design Model TR10-D Temperature Threaded resistance thermometer Miniature design Model TR10-D WIKA data sheet TE 60.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion

More information

Threaded thermocouple Miniature design Model TC10-D

Threaded thermocouple Miniature design Model TC10-D Temperature Threaded thermocouple Miniature design Model TC10-D WIKA data sheet TE 65.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion technology

More information

LS 5000 series Vibration Level Switch for liquids

LS 5000 series Vibration Level Switch for liquids Vibration Level Switch for liquids Set-up without adjustment Integrated fault monitoring Unaffected by product variations in density, conductivity, dielectric constant or viscosity Insensitive to foam,

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Electronic pressure switch with display For sanitary applications Model PSA-31

Electronic pressure switch with display For sanitary applications Model PSA-31 Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES For liquids and solids NIVOSWITCH VIBRATING FORK LEVEL SWITCHES OUR PROFESSION IS YOUR LEVEL LEVEL SWITCHES O U R P R O F E S S I O N I S NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini

More information

Level gauges Series LS Level indicator, switch and transmitter for liquids

Level gauges Series LS Level indicator, switch and transmitter for liquids Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm

More information

Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063

Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063 Mechatronic pressure measurement Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063 WIKA data sheet PV 12.03 for further approvals see page

More information

Electronic pressure switch with display For sanitary applications Model PSA-31

Electronic pressure switch with display For sanitary applications Model PSA-31 Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm Electronic pressure measurement Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm WIKA data sheet PE 81.25 for further approvals see page 5 MicroTronic

More information

Inductive sensor BI5-EM18-Y1X-H1141

Inductive sensor BI5-EM18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75 Level Transmitter Construction The GEMÜ level transmitter has an immersion tube with reed contacts and a chain of resistors which are triggered by a float with an integrated permanent magnet. A threaded

More information

Adapter system for measuring instruments with G1 hygienic connection Model process adapter

Adapter system for measuring instruments with G1 hygienic connection Model process adapter Accessories Adapter system for measuring instruments with G1 hygienic connection Model 910.61 process adapter WIKA data sheet AC 09.20 Applications Food, beverage and pharmaceutical industry Cosmetics

More information

Precision digital pressure gauge Model CPG1500

Precision digital pressure gauge Model CPG1500 Calibration technology Precision digital pressure gauge Model CPG1500 WIKA data sheet CT 10.51 for further approvals see page 4 Applications Oil and gas industry Maintenance and service facilities Calibration

More information

Electronic pressure switch with display Model PSD-4

Electronic pressure switch with display Model PSD-4 Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

ProcessCalibrator Model CPH6000

ProcessCalibrator Model CPH6000 Calibration technology ProcessCalibrator Model CPH6000 WIKA data sheet CT 15.01 Applications Calibration service companies/service industry Maintenance facilities Measurement and control laboratories Quality

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52 Pressure Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52 WIKA data sheet PE 88.03 for further approvals see page 5 Applications For monitoring air, non-inflammable and

More information

FOR LIQUIDS AND SOLIDS

FOR LIQUIDS AND SOLIDS FOR LIQUIDS AND SOLIDS LEVEL SWITCHES VIBRATING FORK LEVEL SWITCHES O U R P R O F E S S I O N NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini compact type Rod extension up to 3 meters (10

More information

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 Pressure Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 WIKA data sheet PE 81.53 for further approvals see page 6 Applications Test bench construction Water jet cutting High-pressure

More information

General Specifications

General Specifications General Specifications Model RAGH Rotameter 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com This type of Rotameter is designed

More information

Micro calibration bath Models CTB , CTB

Micro calibration bath Models CTB , CTB Calibration technology Micro calibration bath Models CTB9100-165, CTB9100-225 WIKA data sheet CT 46.30 for further approvals see page 3 Applications Calibration in the pharmaceutical industry and in the

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

General Specifications

General Specifications General Specifications Model RAGH Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. The mounting position is

More information

Threaded resistance thermometer Model TR10-C, with protection tube

Threaded resistance thermometer Model TR10-C, with protection tube Electrical temperature measurement Threaded resistance thermometer Model TR10-C, with protection tube WIKA data sheet TE 60.03 for further approvals see page 2 Applications Machine building, plant and

More information

Threaded resistance thermometer With protection tube Model TR10-C

Threaded resistance thermometer With protection tube Model TR10-C Temperature Threaded resistance thermometer With protection tube Model TR10-C WIKA data sheet TE 60.03 for further approvals see page 2 Applications Machine building, plant and vessel construction Energy

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Resistance thermometer For additional thermowell Model TR10-B

Resistance thermometer For additional thermowell Model TR10-B Temperature Resistance thermometer For additional thermowell Model TR10-B WIKA data sheet TE 60.02 for further approvals see page 2 Applications Machine building, plant and vessel construction Energy and

More information

Bayonet resistance thermometer Model TR53

Bayonet resistance thermometer Model TR53 Temperature Bayonet resistance thermometer Model TR53 WIKA data sheet TE 60.53 for further approvals see page 2 Applications Plastics processing machinery Injection moulding machinery Cylinder heads and

More information

Capacitance level switches LS 210 LS 220

Capacitance level switches LS 210 LS 220 KROHNE 03/2001 7.02374.31.00 GR/PRINTO Capacitance level switches Compact switches for liquids, solids, slurry, foam and interface; outstanding performance for a low price Easy to install, no moving parts,

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

Differential pressure sensor For ventilation and air-conditioning Model A2G-50 Electronic pressure measurement Differential pressure sensor For ventilation and air-conditioning Model A2G-50 WIKA data sheet PE 88.02 for further approvals see page 5 Applications For measuring differential

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Operating Instructions

Operating Instructions Operating Instructions t i SPAN NOT USED - - 4...20mA DISPLAY t i SPAN END POINT DISPLAY Ð - 4...20mA p Safety information, Note Ex area Safety information Please read this manual carefully, and also take

More information

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing Vane wheel probe BFA25 for flow measurement of gases and liquids with egrated, configurable transducer UFA in Ex-d housing Drawing 5 Vane wheel flow probe BFA25 (Dimensions see Page 3) Measurable variables

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0. LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mh O up to 0... 50 mh O Output signals -wire: 4... 0 ma -wire: 0...

More information

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0. Pressure Port With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: 0. % FSO Nominal pressure from 0... 60 bar up to 00 bar Contacts, or independent PNP contacts, freely configurable

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure Indication and Adjustment Product Information VEGADIS 61 Level Switching Pressure 2 VEGADIS 61 Contents Contents 1 Product description...4 1.1 Configuration... 4 1.2 Principle of operation... 4 1.3 Adjustment...

More information

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >

More information

Standard reference resistor Model CER6000

Standard reference resistor Model CER6000 Calibration Standard reference resistor Model CER6000 WIKA data sheet CT 70.30 Applications Primary standards for voltage and resistance in calibration laboratories worldwide Calibration reference for

More information

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor with analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection

More information

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mho up to 0... 00 mho Output signals wire:... 0 ma wire: 0... 0 V others

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

Precision thermometer Model CTR5000

Precision thermometer Model CTR5000 Calibration technology Precision thermometer Model CTR5000 WIKA data sheet CT 60.20 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference

More information

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 Electronic pressure measurement Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 WIKA data sheet PE 81.53 Applications Test bench construction Water jet

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

standard, short, preferential, top

standard, short, preferential, top ipf electronic gmbh Kalver Straße 27 standard design short design preferential series top series standard, short, preferential, top norm sensing ranges, increased sensing ranges 1100 1 2 1100 norm sensing

More information

Precision hand-held pressure indicator Model CPH6400

Precision hand-held pressure indicator Model CPH6400 Calibration technology Precision hand-held pressure indicator Model CPH6400 WIKA data sheet CT 14.01 Applications Calibration service companies and service industry Measurement and control laboratories

More information

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO. LMP 08i Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mh O up to 0... 00 mh O Output signals wire:... 0 ma wire:

More information

Electronic pressure switch with display For sanitary applications Model PSA-31

Electronic pressure switch with display For sanitary applications Model PSA-31 Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 for further approvals see page 8 Applications Food and beverage industry

More information

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor.   Operating Instructions: EN. EN/2017-04-03 Design and specifications subject to change without notice English page 1 8 Field of application CombiTemp TFRx is a temperature sensor, based on RTD technology, which is designed and produced

More information

Safety instructions VEGATOR 121, 122

Safety instructions VEGATOR 121, 122 Safety instructions Intrinsic safety IECEx TUN 14.0005X Document ID: 47471 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Installation... 4 Supplementary documentation:

More information

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505 Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Series DiTemp Series SolarTemp. Digital Thermometers

Series DiTemp Series SolarTemp. Digital Thermometers JJ Series DiTemp JJ Series SolarTemp Digital Thermometers DS_Digital_thermometers /7 Without external power supply The SolarTemp and DiTemp series offers remarkable features and performance characteristics

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

M E M O R A N D U M I.S.

M E M O R A N D U M I.S. Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M

More information

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES O U R P R O F E S S I O N MULTIFUNCTIONAL CURRENT CONTROLLED SWITCH MODULES MAIN FEATURES 4 20 ma input Relay output Rail mountable Intrinsically safe Associated

More information

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7 90 NAMUR /, / and / directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT, G /, / NPT NAMUR-interface For single and double operated actuators

More information

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information Separating and protective instruments Separating and protective instruments VEGATRENN 149AEx Separator type KFDO Barrier type 9001 Product Information Content Content 1 Product description..........................................................................

More information

Float Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65

Float Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65 Float Flow Meter Flow measurement for translucent liquids and gases DN10 to DN65 mm If a medium sufficient flow rate flows from bottom to top through a vertically inserted measuring tube, then the floated

More information

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5 EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Pressure Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics and pneumatics Pumps and

More information

Hand-held thermometer, precision version Model CTH6500 Model CTH65I0, Ex version

Hand-held thermometer, precision version Model CTH6500 Model CTH65I0, Ex version Calibration technology Hand-held thermometer, precision version Model CTH6500 Model CTH65I0, Ex version WIKA data sheet CT 55.10 for further approvals see page 2-3 Applications Calibration of thermometers

More information

Variable Area Flowmeter DATASHEET

Variable Area Flowmeter DATASHEET Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength

More information

Hand-held thermometer, industrial version Model CTH6300 Model CTH63I0, Ex version

Hand-held thermometer, industrial version Model CTH6300 Model CTH63I0, Ex version Calibration technology Hand-held thermometer, industrial version Model CTH6300 Model CTH63I0, Ex version WIKA data sheet CT 51.05 for further approvals see page 2-3 Applications Calibration service companies

More information

Programming unit VIATOR HART modems Model PU-H

Programming unit VIATOR HART modems Model PU-H Accessories Programming unit VIATOR HART modems Model PU-H WIKA data sheet SP 10.12 for further approvals see page 5 Applications Personal computer HART modem Communicates with all registered s Operates

More information

Temperature dry-well calibrator Models CTD , CTD

Temperature dry-well calibrator Models CTD , CTD Calibration technology Temperature dry-well calibrator Models CTD9300-165, CTD9300-650 WIKA data sheet CT 41.38 for further approvals see page 3 Applications Bio and pharmaceutical industries Food industry

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure

More information

selection of special materials is available to handle almost any fluid.

selection of special materials is available to handle almost any fluid. For Pressure Transmitters and Bourdon Tube Pressure Gauges Types 839 X Chemical Seals for Various Applications Advantages / Benefits Separation of medium and measuring device in difficult applications

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

Precision digital pressure gauge Model CPG1500

Precision digital pressure gauge Model CPG1500 Calibration technology Precision digital pressure gauge Model CPG1500 WIKA data sheet CT 10.51 for further approvals see page 4 Applications Oil and gas industry Maintenance and service facilities Calibration

More information

HERION SERIES Indirect solenoid actuated spool valves

HERION SERIES Indirect solenoid actuated spool valves HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free

More information

Portable Multi-Function Calibrator Model CEP6000

Portable Multi-Function Calibrator Model CEP6000 Calibration Technology Portable Multi-Function Calibrator Model CEP6000 WIKA Data Sheet CT 83.01 Applications Calibration service companies/service industry Instrument and control workshops Industry (Laboratories,

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2 > For use in hazardous areas with gas group IIB+H 2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information