DPC Warning. ! Do not pull the cable. Water Pump Digital Pressure Controller Installation and Operation Manual.

Size: px
Start display at page:

Download "DPC Warning. ! Do not pull the cable. Water Pump Digital Pressure Controller Installation and Operation Manual."

Transcription

1 11.Warning Assemble tool! Do not pull the cable! Do not poke the port! WARNING Wire conductors must not be exposed to avoid any shortage from the conductor end. DPC-10 Water Pump Digital ure Controller Installation and Operation Manual EVAK PUMP TECHNOLOGY CORP. No. 551, Zhongshan Rd., Qingshui Dist., Taichung City 436, Taiwan. TEL: Fax: Vol.PMDPC R2-2IN2OUT

2 1.DPC-10 Panel introduction Model Number LED Light LCD Display Dry Running Over ure Digital ure Controller DPC-10 bar kg/cm 2 psi ure Unit Button Technical Data Power : Vac±10% 50/60HZ Max :12A / Max :10bar / IP55 2.Technical data» Supply voltage: 110~230Vac ± 10% 50/60HZ» Maximum ambient temperature: +40» Maximum liquid temperature: +65» Maximum system pressure: 10bar» Maximum contact load AMP: 12A» Ingress Protection Rating: IP55» Relay Capacity: 1HP in 110V or 2HP in 230V» The digital pressure controller can control pump with higher output through a contactor with control circuit voltage of 110Vac or 230Vac, in the other hand, the supply voltage to DPC is 110Vac or 230Vac 50/60hz, please refer to the wiring diagram for requirement. 02

3 3.Wiring diagram! WARNING Incorrect wiring could cause damage to the pressure controller, confirm the color of the wires with the operation manual before wiring. a. Single phase wiring connection c. Three phase wiring connection-380v 3 4W AC 380V! WARNING R S T N NFB (MCCB) Beware of any connection to the contactor. Please add a R.C. capacitor (spark eliminator) to reduce the possible electromagnetic interference. Note: If the voltage is over 250V, please add transformer by yourself. 220V( <250V) Brown Blue 1 AC 110V,230V L NFB (MCCB) Brown N Blue M1 U V W 3 phase PUMP AC 230V M1 Coil Black Controller DPC-10 Gray b. Three phase wiring connection-230v 3 3W AC 230V R S T! WARNING NFB (MCCB) M1 U V W 3 phase PUMP Black Controller AC 230V M1 Coil DPC-10 1 phase PUMP Gray Any connection to the contactor, please add a R.C capacitor (spark eliminator) to reduce the possible electromagnetic interference. Black Brown Controller DPC-10 Gray Blue If installing DPC-10 with a varistor, please connect varistor wire in parralled with * thin Brown and Blue wires of the DPC-10.! WARNING If connecting to a pump driven by 3ph/380V pump (Please note the power voltage must not exceed 400V.), the blue wire must not connect to R or S wire, otherwise the DPC-10 controller will be burned out. 4.Button Function Introduction Button Icon Function Possible with Button Browsing original pressure value. Long press for 6 seconds to Lock/Unlock the SET button for privacy. Downward adjustment of the parameter value. Short press once: Switch to Basic parameter setting Hold down the botton for 3 seconds: Switch to Advance parameter setting After entering the parameter setting,short press once again: Switch to next setting mode and enter the set value Pump start and stop operation Upward adjustment of the parameter value. 04

4 5.The status of LED lights Item Light Message indication Pump status 1 Non Control loop off from the system Pump off 2 Green Control loop is loaded into the system Pump standby 3 4 Orange Red Control loop commands the system pump to start running Warning message to shut down the system temporarily Pump on Pump auto stop and display the fault message (Dry running or Over pressure) 6.Parameter display and settings (ure value display) Item Parameter Display Code Default Unit 1 Max. ure P-max kg/cm² setting display 2 3 Min. ure setting display ure of water shortage setting display (Dry running) Lock/Unlock Setting function P-min kg/cm² P-Dry kg/cm²» once: To see the Max. pressure setting value.» Or stay on this screen for 5 seconds it will automatically return to the current pressure status display.» again: To see the Min. pressure setting value.» Or stay on this screen for 5 seconds it will automatically return to the current pressure status display.» again: To see the pressure of water shortage setting value.» Or stay on this screen for 5 seconds it will automatically return to the current pressure status display. Long press for 6 seconds (Lock/Unlock the SET button) kg/cm² (Restart or stop the pump running) Item Parameter Pump action Light 1 Restart (ON) Pump on Orange once to restart the pump running. 2 Stop (OFF) Pump off Non Hold down for 3 seconds to stop the pump running. (Short press once to enter Basic Setting Mode) Setting procedure : Max. pressure Min. start pressure Time-Delay Item Parameters Display Code Max. pressure setting (high pressure) Min. start pressure setting (low pressure) Time-Delay setting when reaching the Max. ure Load for 3 seconds to store setting value Default Unit P-max kg/cm² P-min kg/cm² Delay load sec Data Range 0.01~ ~ ~ a.select to modify Max. ure, press the left or right button to adjust the value, after finishing the setting, press the SET button once and go to Min. start pressure setting. c.choose not to modify the pressure, press the SET button, and go to next parameter setting. a.select to modify Min. start pressure, press the left or right button to adjust the value, after finishing the setting, press the SET button once and go to Time-Delay setting. c. Choose not to modify the pressure, press the SET button, and go to next parameter setting. a.select to modify the Time-delay setting when reaching the Max. ure, press the left or right button to adjust the value, after finishing the setting, press the SET button and go to " load " display. c.choose not to modify the delay time, press the SET button, and LCD display " load " The above setting value is stored and after 3 seconds will automatically return to the current pressure value. 06

5 Hold down for 3 seconds (Advanced setting Mode) Item Parameters Display Code Default Data Unit Range Switch the display working pressure unit Detection time setting of water shortage ure of water shortage setting (Dry running) Unit - - P-Dry sec 1~120 P-Dry kg/cm² 0.01~ a.select to switch the Unit of working pressure, press the right button to change the pressure unit (Cycle : kg/cm² Psi bar kg/cm²), then press the SET button once and go to next parameter setting. c.choose not to modify the working pressure unit, press the SET button once, and go to next parameter setting. a.select to modify the detection time after reaching the pressure setting of water shortage (Dry running), press the left or right button to adjust the value, after finishing the setting, press the SET button and go to next parameter setting. c.choose not to modify P-Dry detection time setting, press the SET button once, and go to next parameter setting. a.select to modify the ure of water shortage, press the left or right button to adjust the value, after finishing the setting, press the SET button and go to next parameter setting. c.choose not to modify the pressure of water shortage, press the SET button, and go to next parameter setting. Item Parameters Display Code Default Data Unit Range 4 5 Time setting of automatic re-start running after warning Auto shutdown (Dry Reset running or Over pressure) (α value) Auto shutdown setting after continuous running Auto sec hour 0~600 St-0 St-.5 St-1 ~ St-5 a.select to modify automatic re-start time, press the left or right button to adjust the value, after finishing the setting, press the SET button, and go to next parameter setting. The time of automatic re-start = (automatic time setting) x (trip times)³ (Cumulative trip times is up to 10 times, if pressing the right button to re-start, then the trip times can be re-calculated.) c.choose not to modify the automatic re-start time, press the SET button, and go to next parameter setting. a.select to modify the auto shutdown setting after continuous running, press the left or right button to adjust the value, after finishing the setting, press the SET button and go to next parameter setting. St-0: ure controller keeps running and won t shut down automatically. St-.5: ure controller will auto shut down after continuously running 0.5 hours and won t auto restart after the shutdown. St-1~5: ure controller will auto shut down after continuously running 1~5 hours and won t auto restart after the shutdown. c.choose not to modify the automatic re-start time, press the SET button, and go to next parameter setting. 08

6 Item Parameters Display Code Default Data Unit Range 6 7 Restore to default value setting LCD screen display load or ---- for 3 seconds to store and finish the setting df-n df-y or load a.select to restore default value settings (df-y), press the right button and adjust the parameter value from df-n to df-y. After finishing the setting, press the SET button, then all the advanced value settings are returned to default value. LCD screen will display " " for 3 seconds and return to the current pressure conditions. c.choose not to return to default value settings (df-n), select df-n and press the SET button again, LCD screen display "load" for 3 seconds and will return to the current pressure conditions automatically. After LCD screen displaying load or ---- for 3 seconds, above setting value is stored and it will automatically return to the current pressure value. 9.The current operating parameters display a-1. once to browse original pressure value 1).Max. pressure setting display (high pressure) (Show code P-max) once 2).Min. start pressure setting display (low pressure) (Show code P-min) 7.Standard default value (Factory preset settings) a. Max. pressure value : 2.5 kg/cm² b. Min. pressure value : 1.5 kg/cm² c. Delay Time when reaching the Max. ure : 15 seconds d. The pressure unit : kg/cm² e. Detection time of water shortage : 30 seconds f. ure of water shortage : 0.5 kg/cm² g. Time of automatic re-start running after warning shutdown (α value) : 60 seconds h. Auto shutdown setting after continuous running : St-0 i. Over pressure value is fixed in 10bar and cannot modify 8.Setting value range a. ure setting range : 0.01 ~ 10.00bar b. Time-Delay setting range : 0 ~ 60 seconds c. Detection time after Dry-running setting range: 1~120 seconds d. Time of automatic re-start running after warning shutdown (α value) setting range : 0 ~ 600 seconds e. Auto shutdown setting range: None and 0.5~5Hours once 3).ure of water shortage setting display (Dry running) (Show code P-Dry) again 10

7 a-2. Long for 6 seconds to Lock/Unlock the SET button b. once to enter basic setting 1).Lock the SET button after long press (Show code ) for 6 seconds 1).Max. pressure setting (high pressure) (Show code P-max) 2).Unlock SET button after long press (Show code UnL) again for 6 seconds once 2).Min. Start pressure setting (low pressure) (Show code P-min) once 12

8 3).Time-Delay setting after reaching the Max. ure (Show code Delay) 5).After finishing above setting, 3 seconds later will return to the current pressure status display automatically. once c. for 3 seconds to enter advanced setting 4).All parameter settings is stored (Show code load) 1).Change the display working pressure unit (Show code Unit) 3 seconds later to set up unit Cycle of working pressure unit: kg/cm² psi bar kg/cm² once 14

9 2).Detection time setting of water shortage (Show code P-Dry & sec) 4).Time setting of automatic re-start running after warning shutdown (Dry running or Over pressure) (α value) (Show code Auto reset) once 3).ure of water shortage setting (Show code P-Dry) once 5). Auto shutdown setting after continuous running (Show code Auto)» St-0: ure controller keeps running and will not automatically shut down.» St-.5&St-1~5: ure controller will auto shut down after continuously running 0.5 or 1~5 hours and will not automatically restart after the shutdown. once once 16

10 6).Restore to default value setting or not» To restore default value settings (show code df-y) 10.Fault Display a).eeee When the pressure controller displays "EEEE" the pressure sensor has failed. to adjust the value to df-y once and restore to default value (Show code ----)» Not to restore default value settings (show code df-n) b).ffff When the pressure controller displays "FFFF" the temperature sensor has failed. c).eeff to set the value to df-n once then all settings are stored. (Show code load) 7).After finishing above settings, LCD screen display load or seconds later, above setting value is stored and it will automatically return to the current pressure value. When the pressure controller displays "EEFF" the pressure and temperature sensor have failed. 18

IPS INTELLIGENT PUMP STARTER

IPS INTELLIGENT PUMP STARTER IPS INTELLIGENT PUMP STARTER The IPS Intelligent Pump Starter features SMARTSTART motor protection, integrated electronic pump protection overload, and power metering and data logging options. Ø & Ø, 0/60

More information

Series Pressure Sensor Instruction Sheet

Series Pressure Sensor Instruction Sheet 2018/05/10 Series ure Sensor Instruction Sheet Thank you very much for choosing Delta DPA series pressure sensor. Please read this instruction sheet carefully before using your DPA. Keep this instruction

More information

Series Pressure Sensor Instruction Sheet

Series Pressure Sensor Instruction Sheet Series ure Sensor Instruction Sheet Thank you very much for choosing Delta DPB series pressure sensor. Please read this instruction sheet carefully before using your DPB. Keep this instruction sheet handy

More information

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02 pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02 pco 3 Controller User Manual Introduction The Airstack Chiller is a modular air-cooled chiller composed of

More information

VLT 2800 DRIVE SPECIFICATIONS

VLT 2800 DRIVE SPECIFICATIONS VLT 2800 DRIVE SPECIFICATIONS Drive Input Power Input voltage 3 phase... 200 through 240, or 380 through 460; 3-phase all ratings 200 through 240, 1-phase through 2 HP Input voltage range for full output...

More information

Installation and Operation Manual SPC1

Installation and Operation Manual SPC1 Installation and Operation Manual SPC1 BIA-SPC1 rev 5 Page 1 TABLE OF CONTENTS Page QUICK GUIDE DRAINAGE PUMP FLOATS CONNECTED TO PANEL 4-5 QUICK GUIDE DRAINAGE PUMP FLOAT CONNECTED TO PUMP 6-7 QUICK GUIDE

More information

AE R6 July 2018 Electronic Unit Controller

AE R6 July 2018 Electronic Unit Controller July 2018 Electronic Unit Controller TABLE OF CONTENTS Safety... 3 Safety Instructions... 3 Safety Icon Explanation... 3 Instructions Pertaining to Risk of Electrical Shock, Fire, or Injury to Persons...

More information

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Tags: P-8 1800RPM Premium Efficient Motor 460/3/60 Pump and Motor Weight: 183lbs

More information

IS -680PD8. Switching Power Supply 680W) SPECIFICATION. Revision: 1.0

IS -680PD8. Switching Power Supply 680W) SPECIFICATION. Revision: 1.0 IS-680PD8 IS -680PD8 Switching Power Supply ( EPS- 680W) SPECIFICATION Revision: 1.0 727,. Phillips Drive City of Industry. CA 91748. USA http:// www.xeal.com.tw TEL: 626-3038885 FAX: 626-3010588 TABLE

More information

Installation and Operation Manual DPC1

Installation and Operation Manual DPC1 Installation and Operation Manual DPC1 BIA-DPC1 rev 5 Page 1 TABLE OF CONTENTS Page QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PANEL 4-5 QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PUMPS 6-7 QUICK

More information

SMARTSTART MOTOR STARTERS

SMARTSTART MOTOR STARTERS SMARTSTART MOTOR STARTERS MCG WWW.MCG-USA.COM 1 AT A GLANCE Covers all line voltages from 200-600V AC, single or three phase Transformer supplies a 24V AC coil voltage, no matter the line voltage 12V AC/DC

More information

FX 2 Instruction Manual

FX 2 Instruction Manual FX 2 Instruction Manual Climma Compact Version Annapolis MD USA 301 352 6962 info@veco-na.com Introduction: The FX2-DX digital controller operates onboard air conditioning equipment to provide room temperature

More information

CM-500 SK 500 USER CODES KEYPAD

CM-500 SK 500 USER CODES KEYPAD CM-500 SK 500 USER CODES KEYPAD Wiring diagram PCB front view ST2 1 3 1 3 N/C contact RL1 (magnet) N/O contact RL1 (strike) ST1 3 2 1 ST2 1 3 RL2 RL1 Strike 2 1 E M B 3 5 T C O 12 V V1 PB2 PB1 Input voltage

More information

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017 APPLICATION CONTROL GUIDELINES IntelliROL Power Supply PN 1176718 Revision Date: March 15, 2017 Table of Contents List of Tables...3 TGW Safety Recommendation...4 Warnings and Safety Instructions...5 Introduction...6

More information

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display. NEW product No, NPPDF 6-01E Large digital sensor 31series SEU-31 Easily viewable LCD dual displays. igh level visibility with 3-color display 2-Color indications depending on output. Main display : Pressure

More information

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved. R & D SPECIALTIES 2004, by R & D Specialties, Inc. All Rights Reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written permission of R & D Specialties.

More information

GFC114. Low Power Flow Computer FEATURES

GFC114. Low Power Flow Computer FEATURES Low Power Flow Computer FEATURES l UNIVERSAL INPUT, 5 khz, CAN POWER THE l SIMPLIFIED MENUS AND PROGRAMMING l NO NEED OF AMPLIFIERS OR LINEARIZERS l SEVEN DIGIT RATE WITH PROGRAMMABLE DECIMAL PLACES l

More information

User Manual. Solar Inverter for Water Pump

User Manual. Solar Inverter for Water Pump User Manual Solar Inverter for Water Pump SP Revival Series Version: 1.2 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...

More information

NFC110. Flow Computer For Low Pulses FEATURES

NFC110. Flow Computer For Low Pulses FEATURES Flow Computer For Low Pulses FEATURES l STABLE READING WITH PULSES DOWN TO ONE PULSE EVERY 5 MINUTES l PULSE FLOW INPUT UP TO 100 Hz, CAN POWER THE SENSOR l WORKS WITH OPTO-COUPLER FLOW METERS l SEVEN

More information

icon Series Controls

icon Series Controls icon Series Controls icon Series Controls Introducing the Bianco icon range of intelligent controllers. The icon range of intelligent controllers are suitable for installation in various Industrial and

More information

SPECIFICATION. Model: OP650 Switching Power Supply With Active PFC PS/2 650W

SPECIFICATION. Model: OP650 Switching Power Supply With Active PFC PS/2 650W SPECIFICATION Model: OP650 Switching Power Supply With Active PFC PS/2 650W 1. General This is the specification of Model OP650; it is intended to describe the functions and performance of the subject

More information

PowerFlex 400 AC Drive Guide Specification

PowerFlex 400 AC Drive Guide Specification PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

Digital Control Panel 240V AC Swing Gates Model : DCP 242 REMOTE TIMER PROGRAM FUNCTION FORCE. Jumpers. Photo Sensor LED

Digital Control Panel 240V AC Swing Gates Model : DCP 242 REMOTE TIMER PROGRAM FUNCTION FORCE. Jumpers. Photo Sensor LED DGTAL COMPUTERZED CONTROL PANEL for 240V ac SWNG GATE MOTORS Model: DCP-242V1 The DCP-242V1 is a universal Control Panel (CP) that can replace any 240V AC control panel for swing gates. t is very simple

More information

Smartstart Control Module

Smartstart Control Module Smartstart TECHNOLOGY What is Smartstart? The patented Smartstart control module is an integrated, seamless solution that incorporates operator control, superior motor protection, and automation system

More information

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display. NEW product No, NPPDF 6-01E-3 Large digital sensor 31series SEU-31 Easily viewable LCD dual displays. igh level visibility with 3-color display 2-Color indications depending on output. Main display : Pressure

More information

RPX Series USER S MANUAL

RPX Series USER S MANUAL RPX Series USER S MANUAL INDEX 1.1 Introduction page 1 1.2 Packing page 1 1.3 Drawing page 2~16 1.4 Features page 17 1.5 Specification page 18~21 1.6 Installation & Testing page 22~23 1.7 Hot-Swap Procedures

More information

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation: DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated

More information

FX2-CHILLER. Digital Control. Operations Manual

FX2-CHILLER. Digital Control. Operations Manual FX2-CHILLER Digital Control Operations Manual Micro Air Corporation Phone (609) 259-2636 124 Route 526 www.microair.net Allentown NJ 08501 Fax (609) 259-6601 Introduction: The FX2-CHILLER digital control

More information

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Table of Contents Introduction...

More information

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703 SC2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Operating Program Revision: 10 Revision Date: 1-9-12 STATION

More information

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,

More information

Pure sine wave inverter. Product Manual

Pure sine wave inverter. Product Manual Product Manual The inverter Installer must be professional, for the high pressure in the inverter, no-professional person please do not open it. The inverter should be installed at a dry, well ventilated

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION Part Name: 91.50012.H01 Model No: HPC-500-H12S Document Version: A0 PRODUCT SPECIFICATION Release Date: 2010/6/30 Approved by : Checked by : Prepared by : HIGH POWER ELECTRONIC CO., LTD SIRFA International

More information

Multi-Range DC Power Supply

Multi-Range DC Power Supply Multi-Range DC Power Supply PSB-1000 Series QUICK START GUIDE GW INSTEK PART NO. 82SB-18000M01 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright.

More information

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8 User Manual 2.2KW/7.5KW/11KW Solar Inverter for Water Pump Version: 1.8 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...

More information

LC-1 Level Controller & Flow Monitor

LC-1 Level Controller & Flow Monitor The Level Controller and Flow Monitor provides a fully integrated Duplex Controller. The unit allows collecting 'rate of flow' information and the verification of the run time characteristics of the external

More information

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Table of Contents Introduction...

More information

GPLS-25 DATASHEET Março 2012

GPLS-25 DATASHEET Março 2012 GPLS-25 DATASHEET Março 2012 THRU-WALL LEVEL SWITCHES GPLS 25 For liquids limit level sensing on non-conductive (glass or plastic) gauge-pipes, tubes and tank walls Miniature performance in plastic housing

More information

REEKBOX.com Thank you for choosing Shenzhen Sundeu Technology Please read the user manual carefully before using the product for any purpose

REEKBOX.com Thank you for choosing Shenzhen Sundeu Technology Please read the user manual carefully before using the product for any purpose User Manual REEKBOX.com Thank you for choosing Shenzhen Sundeu Technology Please read the user manual carefully before using the product for any purpose Product introduction The REEBOX V1.2 is a electronic

More information

TPI (Turbine Pump Interface) Guide

TPI (Turbine Pump Interface) Guide (Turbine Pump Interface) Guide Using Franklin Fueling Systems Series Fuel Management System Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838

More information

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index

More information

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any MCTRL R5 Independent Controller Product Version: Document Number: V1.0.1 NS110100550 Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced,

More information

Owner s Manual. Digital Player Addendum. For Heat Siphon Swimming Pool Heat Pumps

Owner s Manual. Digital Player Addendum. For Heat Siphon Swimming Pool Heat Pumps Made in Latrobe Since 1983 Pennsylvania U.S.A. Owner s Manual Digital Player Addendum For Heat Siphon Swimming Pool Heat Pumps Heating Only Models: Z250HP, Z375HP, Z575HP & Z700HP Z250HP50, Z375HP50, Z575HP50

More information

Top Microsystems Proprietary Specification P/N: P6301H N1F SK SPECIFICATION P/N: P6301H N1F

Top Microsystems Proprietary Specification P/N: P6301H N1F SK SPECIFICATION P/N: P6301H N1F SPECIFICATION P/N: P6301H N1F Industrial Quality 1U Mini 300W ATX Power Supply (81.5x150x40.3 mm) Active PFC 100V-264V AC Input *** Specification Approval *** This specification (total 10 pages including

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章 S150,S300 Series Pure Sine Wave Inverter User s Manual List of contents 1. IMPORTANT safety Information... 1 1-1 General Safety Precautions.. 1 1-2 Battery Precautions 1 2. Features. 2 2-1 Electrical Performance

More information

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available

More information

(ATX12V) Uninterrupted Switching Power Supply Technical Specification

(ATX12V) Uninterrupted Switching Power Supply Technical Specification AUP-X-400-V4 (ATX12V) Uninterrupted Switching Power Supply Technical Specification Part No. REVISION HISTORY VERSION RELEASE DATE NOTES DATE 1. MAR-2011 IMPROVE THE EFFICIENCY NOT LESS THAN 80% AND COMPLAIN

More information

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function. Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Application Examples Detecting slackness in sheet materials Detecting liquid levels Remotely detecting

More information

ATS CONTROLLER [ ACD-III ], [ ACD-III-C ] User s Manual. O-Sung Electric Machinery Co., Ltd.

ATS CONTROLLER [ ACD-III ], [ ACD-III-C ] User s Manual. O-Sung Electric Machinery Co., Ltd. ATS CONTROLLER [ ACD-III ], [ ACD-III-C ] User s Manual O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea Tel : (031) 944-3521 / Fax : (031) 944-3525 http://www.osemco.com

More information

DG-800 Stand-Alone Proximity Reader Instruction Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity

More information

JOCKEY FIRE PUMP CONTROL MODEL: FPC Series

JOCKEY FIRE PUMP CONTROL MODEL: FPC Series JOCKEY FIRE PUMP CONTROL MODEL: FPC-70010 Series INTRODUCING The Jockey/Jacking pump controller is for the control and status display of a Jockey/Jacking pump. The intuitive design and functions of this

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS CONTENT: 1. Important safety instructions 2. Specifications and main dimensions 3. Parts included 4. Control box 5. Installation 6. Adjusting the stroke length of the lift 7.

More information

Telephony Multi-Taps. 9000T-TP Series

Telephony Multi-Taps. 9000T-TP Series 9000T-TP Series The 9000T-TP series 1 GHz twisted-pair power multi-tap taps off part of its input RF and AC, but lets the rest pass through. It divides the tapped-off signal and power into multiple outputs,

More information

Automatic Transfer Switch OTM_C_20D. Installation and Operation Instructions

Automatic Transfer Switch OTM_C_20D. Installation and Operation Instructions Automatic Transfer Switch OTM_C_20D Installation and Operation Instructions Contents 1 SYMBOLS & TERMS... 1 1.1 USE OF SYMBOLS... 1 1.2 EXPLANATIONS OF ABBREVIATIONS AND TERMS... 1 2 PRODUCT OVERVIEW...

More information

DALI Professional Controller-4. Control unit Operating instructions

DALI Professional Controller-4. Control unit Operating instructions LI Professional Controller-4 Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Configuration 5 Design 5 Connections

More information

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions GRUNDFOS INSTRUCTIONS Control MPC Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions CONTENTS Page

More information

Installation Instructions

Installation Instructions Please read all instructions before installing RS-350 PIR Dual Relay Universal Application Wall Switch Vacancy Sensor with Manual ON/OFF Lens Lighted Switch ON/OFF button for Relay 1 ON/OFF button for

More information

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review... TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...

More information

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch ZSE3A(F)/E3A Series RoHS Can copy to up to 1 switches simultaneously. setting labor Minimizing ZSE3 E3 ZSE4 E4 The settings of the master sensor can

More information

SED2 Variable Frequency Drives

SED2 Variable Frequency Drives SED2 Variable Frequency Drives Startup Procedure and Checklist Document No. 155-718 Table of Contents Prerequisites...1 Preparing for SED2 VFD Startup...1 HVAC Startup Procedure for SED2 with Bypass Option...4

More information

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015 ESC 201 Installation and Operating Instructions Manual SG-0002-03 Jan 2015 Table of Contents 1.0 FUNCTIONS... 5 2.0 FEATURES... 5 3.0 ESC 201 DESCRIPTION... 6 4.0 GENERAL OPERATIONS... 6 4.1 MANUAL MODE

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL PHASETRONICS Specialists EP1 Series Power Control Single Phase SCR 10-50 Amps OPERATION & SERVICE MANUAL Phasetronics, Inc. P.O. Box 5988 1600 Sunshine Drive Clearwater, FL 33765 (727)573-1900 FAX(727)573-1803

More information

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

INSTALLATION INSTRUCTIONS Model 930 EntryCheck SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 930 EntryCheck

More information

Delta Multifunction Pressure Sensor DPA Series

Delta Multifunction Pressure Sensor DPA Series Automation for a Changing World Delta Multifunction Pressure Sensor DPA Series www.deltaww.com Multifunction Pressure Sensor DPA Series Energy-saving mode Various unit conversion function Various output

More information

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

Sidewinder Pumps Inc. AC C1D2 Timer/Controller Sidewinder Pumps Inc. AC C1D2 Timer/Controller Page 1 of 14 Rev 4/26/17 Table of Contents 1. Warnings --------------------------------------------------------------------------------------------------

More information

USER S MANUAL. DAS-G01 The Power of Tomorrow

USER S MANUAL. DAS-G01 The Power of Tomorrow USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 0 USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 Page 1 USER'S MANUAL TABLE OF CONTENTS Page # 1.0 GENERAL INFORMATION...

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 850 Pressure English *850.090* 850.090 Rev. H /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.

More information

Central Controller Operation & Installation Manual

Central Controller Operation & Installation Manual Central Controller Operation & Installation Manual YCZ-A004 CONTENT Function introduction of central controller... 1 Part info for central controller... 2 Page & Key Explanation... 4 Address Setting When

More information

IS-900R2UPD8G. Redundant Power Supply. Active PFC 900W + 900W. 80+ Gold Efficiency SPECIFICATION. Revision: 1.0

IS-900R2UPD8G. Redundant Power Supply. Active PFC 900W + 900W. 80+ Gold Efficiency SPECIFICATION. Revision: 1.0 IS-900R2UPD8G IS-900R2UPD8G Redundant Power Supply Active PFC 900W + 900W 80+ Gold Efficiency SPECIFICATION Revision: 1.0 727,. Phillips Drive City of Industry. CA 91748. USA http:// www.xeal.com TEL:

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

ATS-PLC Ver1.0 PROGRAMMABLE TOUCH-SCREEN AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

ATS-PLC Ver1.0 PROGRAMMABLE TOUCH-SCREEN AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL ATS-PLC Ver1.0 PROGRAMMABLE TOUCH-SCREEN AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL Headquarters : No.3, Lane 201, Chien Fu St., Chyan Jenn Dist., Kaohsiung, TAIWAN Tel : + 886-7-8121771

More information

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER SERIES CMT CARBON MONOXIDE GAS TRANSMITTER INSTALLATION OPERATION AND MAINTENANCE MANUAL DWYER INTRUMENTS, INC. PO BOX 373, MICHIGAN CITY, IN. 46360 USA PHONE: 800-872-9141 FAX: 219-872-9057 Web: www.dwyer-inst.com

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

SMART SHOT CONTROLLER FLUID USERS GUIDE

SMART SHOT CONTROLLER FLUID USERS GUIDE SMART SHOT CONTROLLER FLUID USERS GUIDE Pg. 2 SMART SHOT CONTROLLER FEATURES 3 SMART SHOT CONTROLLER FEATURES 3 SMART SHOT CONTROLLER CONFIGURATIONS 4 FLOAT/SENSOR WIRING 5 TOP AND BOTTOM FLOAT/SENSOR

More information

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website: SC2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision: 12 Revision Date: 8-27-14

More information

High Pressure E/P Regulator. ITVH Series

High Pressure E/P Regulator. ITVH Series Doc. No. DIQ-69200-OM002-A P R O D U C T N A M E High Pressure E/P Regulator MODEL/ Series/ Product Number ITVH Series Install and operate the product only after reading the Operation Manual carefully

More information

Table of Contents. Safety. Attention. Warnings

Table of Contents. Safety. Attention. Warnings Solstart Miniature Soft Starter 8-58A, 220-600V Instruction Manual Ver. 21.2. 2002 Table of Contents Page Subject 3 Starter Selection 4 Installation Notes 5 Wiring 6 Starter Settings & Start-up Procedure

More information

Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430. Operation Manual

Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430. Operation Manual Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430 Operation Manual INDEX 1 Specifications 2 Assembly and installation 2.1 Precautions for installation 2.2 Installation of controller

More information

Automation Interface Requirements for System I/O Interface of a DPC I Welding System

Automation Interface Requirements for System I/O Interface of a DPC I Welding System - 1 - Automation Interface Requirements for System I/O Interface of a DPC I Welding System The DPC I welding system offer several features that are intended to communicate with automation. These features

More information

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01 Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation

More information

Warning! It will cause malfunction if the monitor is operating with unspecified power supply adaptor or incorrect power voltage. Do not expose this

Warning! It will cause malfunction if the monitor is operating with unspecified power supply adaptor or incorrect power voltage. Do not expose this User Manual / Installation Guide Model No. P150VR/P150VG Warning! It will cause malfunction if the monitor is operating with unspecified power supply adaptor or incorrect power voltage. Do not expose this

More information

SELECTRONIX, INC. SUPERSTEP SERIES 4000 SEQUENCING STEP CONTROLLERS WOODINVILLE, WA INSTALLATION & OPERATING ADDENDUM LOAD LIMIT INPUT CONFIGURATIONS

SELECTRONIX, INC. SUPERSTEP SERIES 4000 SEQUENCING STEP CONTROLLERS WOODINVILLE, WA INSTALLATION & OPERATING ADDENDUM LOAD LIMIT INPUT CONFIGURATIONS SELECTRONIX, INC. WOODINVILLE, WA SUPERSTEP SERIES 4000 SEQUENCING STEP CONTROLLERS INSTALLATION & OPERATING ADDENDUM LOAD LIMIT INPUT CONFIGURATIONS Rev 03/10/19 2 1 Various DC Voltage - 100 % Load Limit

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

ATS CONTROLLER OPERATING MANUAL

ATS CONTROLLER OPERATING MANUAL HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER OPERATING MANUAL Smartgen Electronic CONTENT 1 SUMMARY... 4 2 PERFORMANCE AND CHARACTERISTICS... 4 3 SPECIFICATION... 5 4 OPERATING... 6 4.1

More information

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

METERING/DISPLAY MANUAL

METERING/DISPLAY MANUAL METERING/DISPLAY MANUAL 175W - 750W SINGLE PHASE Series LV EMERGENCY LIGHTING CENTRAL INVERTER Myers Power Products, Inc. 44 South Commerce Way, Bethlehem, PA 18017 1-800-526-5088 (610) 868-3500 Fax: (610)

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

120 WATT FLEX ATX TYPE WITH ACTIVE PFC

120 WATT FLEX ATX TYPE WITH ACTIVE PFC 120 WATT FLEX ATX TYPE WITH ACTIVE PFC FXA120-W-F SERIES GENERAL SPECIFICATION This specification describes the performance characteristics of a grounded, with active PFC function, single phase, 120 watts,

More information

Q9 ASD LOW VOLTAGE DRIVE

Q9 ASD LOW VOLTAGE DRIVE ASD LOW VOLTAGE DRIVE HVAC-MINDED, SYSTEM FRIENDLY RELIABLE Toshiba has manufactured pulse-width modulated drives since 1981 and is one of the few companies that manufactures both motors and drives in

More information

LC-5 Level Controller & Flow Monitor

LC-5 Level Controller & Flow Monitor The Level Controller and Flow Monitor provides a fully integrated Duplex Controller supporting both analog and discrete (float switch) level detection. The unit allows collecting 'rate of flow' information

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Operation Guide CT100

Operation Guide CT100 Operation Guide CT100 PG 1 The CT100 communicating Z-Wave thermostat operates via a high-quality, easy-to-use touch screen. To set or adjust your CT100, simply touch your finger firmly to the screen. The

More information

Compressor Controller MAM 890

Compressor Controller MAM 890 Compressor Controller MAM 890 OPERATION MANUAL Revision 1.0 04.08.2017 Notice Please read all the operation manual before operating the set and keep this manual for further reference. Installation of MAM

More information

VFD with Bypass package for HVAC Applications. Introducing the ABB E-Clipse Bypass

VFD with Bypass package for HVAC Applications. Introducing the ABB E-Clipse Bypass VFD with Bypass package for HVAC Applications Introducing the ABB E-Clipse Bypass ABB E-Clipse Bypass What Is It? ABB s Next Generation HVAC Bypass Replacement to the Current ABB E-Bypass Offering E-Clipse

More information

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD CONTENT 1 OVERVIEW... 5 2 PERFORMANCE AND CHARACTERISTICS... 6 3 SPECIFICATION... 8 4 OPERATING...

More information

Sidewinder Pumps Inc. AC Timer/Controller

Sidewinder Pumps Inc. AC Timer/Controller Sidewinder Pumps Inc. AC Timer/Controller Page 1 of 12 Rev 032417 Table of Contents 1. Warnings-------------------------------------------------------------------------------------------------- 3 1.1.

More information