Data logger / EASYBus

Size: px
Start display at page:

Download "Data logger / EASYBus"

Transcription

1 Logger / EASYBus Application: Standard signal Data logger (compatible to USB) Data logger / EASYBus EL-USB-2-LCD EL-USB-TC-LCD T-Logg T-Logg T-Logg 160 Temperature Humidity USB-Connection direct direct USB 100 Datenlogger (compatible to EASYBus) Handheld instrument Display / Controller Logger / EASYBus Transmitter Application: Standard signal EASYLog 40 K.. EASYLog 40IMP/.. EASYLog 24 RFT.. EASYLog 40NS.. Temperature Humidity Pressure (abs.) Pulse State EASYLog 40 BIN EASYBus-load EASYLog 80 CL Temperature probe Alarm / Protection Software information on Logger / EASYBus p.r.t. page

2 Handheld instrument USB Data Logger with display T-Logg The logger series for stand-alone applications Temperature-Logger Alarm / Protection Temperature probe Transmitter Logger / EASYBus Display / Controller FOR EXTERNAL THERMOCOUPLES (J, K AND T) OR HUMIDITY / TEMPERATURE AND DEW POINT EL-USB-2-LCD Product-ID: (device + software) USB Data Logger for Humidity / Temperature and Dew Point EL-USB-TC-LCD Product-ID: (device + software) USB Data Logger for external Thermocouples (J, K and T) Description: Direct connection to USB interface 2 programmable alarm limits LED for indication of low battery power Data logger with display red, green and orange LED for system status Protection class IP67 incl. software Specification EL-USB-2-LCD: Measuring Range: Temperature: C % RH Dew Point via software Resolution: 0.5 C / 0.5 % RH Accuracy: Temperature (typ): ± 1 C ± 3,5 % RH (in the range % RH) Dew Point: ± 2 C (in the range % RH / 25 C) Memory: recordings per humidity and temperature Logging Interval: 10 s, 1 min, 5 min, 30 min, 1 h, 6 h, 12 h programmable via software Serial USB 3.6 V lithium battery, size 1/2 AA, Dimensions housing: 103 x 26.4 mm (L X W), Ø 27 mm Scope of supply: 1 device incl. lithium battery 3.6 V, 1 software, 1 protection cap, 1 operating manual (on CD-ROM), 1 clip Specification EL-USB-TC-LCD: Measuring Range: Type J: C, Type K: C Type T: C Resolution: 0.5 C Accuracy (typ.): ± 1.0 C (at nominal temperature 25 C) Thermocouple Connectors: Memory: Thermoelement socket in miniature size, suitable for fl at-pin plugs data Logging Interval: 1 s, 10 s, 1 min, 5 min, 30 min, 1 h, 6 h, 12 h, adjustable via software Operating Temperature: C Serial USB 3.6 V Lithium battery, size 1/2 AA Dimensions: x 26.8 mm (L X W), Ø 27 mm Scope of supply: 1 device incl. 3.6 V lithium battery, 1 software, 1 protection cap, 1 operating manual (on CD-ROM), 1 clip, 1 wire temperature probe Special EL-USB-2-LCD and EL-USB-TC-LCE are neither BUS- nor E.A.S.Y.Bus compatible. T-Logg 100 E T-Logg 100 DIN EN T-Logg 100 Product-ID: Temperature data logger ( measurement values) for any application T-Logg 100 E Product-ID: Temperature data logger ( measurement values) for any application Starter kit T-Logg 100 SET Product-ID: Complete set: T-Logg USB 100 (incl. software) FREE SOFTWARE FOR SETTING, READING-OUT SAVING AND ANALYZING Measuring range: T-Logg 100: C T-Logg 100 E: C Resolution: 0,1 C Accuracy (at nominal temperature = 25 C) T-Logg 100: ±0.5 C T-Logg 100 E: ±0.2 % of measuring value ±0.5 C Sensor: T-Logg 100: integrated in device T-Logg 100 E: sensor tube made of stain-less steel, Ø 5 mm, approx. 50 mm long, approx. 1 m silicone cable. Cable with anti-buckling glanding to housing. LCD-display, 10 mm high from 2 s... 5 h, free programmable via software capacity: measuring values time: 166 days (if interval is 15 min.) Working C C CR 2032, exchangeable Battery service over 3 years Approvals: DIN EN serial interface, 3-pin miniature integral plug. Housing: 48.5 x 48.5 x 35.5 mm (L x W x D) plugs, sensor connection,... are not included, Housing made of shock resistant plastic, transparent front made of polycarbonate. splash water-proof: IP 65. the T-Logg 100 have been manufactured in accordance with the regulations concerning EMC (2004/108/EG). The device meets EN (table 2, class B), additional error: < 0.5 % (< 1 % at T-Logg 100 E) The T-Logg 100 is not suitable for bus operation and is not E.A.S.Y.Bus compatibel. 98 further informationen on

3 Logger / EASYBus T-Logg The logger series for stand-alone applications Standard signal-logger T-Logg 120 W T-Logg The logger series for stand-alone applications Humidity- / Temperature-Logger Handheld instrument T-Logg 120 K T-Logg 120 W -... Standard signal data logger ( measuring values) for transducers etc. (with elbow type plug) T-Logg 120 K -... Standard signal data logger ( measuring values) for transducers etc. (with PG glanding and cable) FREE SOFTWARE FOR SETTING, READING-OUT SAVING AND ANALYZING please specify standard signal desired when ordering (i.e.: T-Logg 120 K - 0-1V) Display range: digit, freely programmable Decimal point: any position Input signal: only one signal! 0-1 V, 0-2 V, 0-10 V, 0-20 ma or 4-20 ma other input signals upon request (input is not isolated from interface) Accuracy: ±0.5 % FS (at nominal temperature) 10 mm high LCD-display from 2 s... 5 h, freely programmable via software capacity: measuring values time: 166 days (if interval is 15 min.) Working C C CR 2032, exchangeable Battery service over 3 years Electric connection: (for input signals) W -..: elbow-plug in accordance with EN /A for connection to an existing transmitter K -..: approx. 0.5 m connection cable serial interface, 3-pin miniature integral plug Housing: 48.5 x 48.5 x 35.5 mm (L x W x D) plugs, sensor connection,... are not included, Housing made of shock resistant plastic, transparent front made of polycarbonate. splash water-proof: IP 65. The T-Logg 100 have been manufactured in accordance with the regulations concerning EMC (2004/108/EG). The device meets EN (table 2, class B), additional error: < 0.5 % The T-Logg 100 is not suitable for bus operation and is not E.A.S.Y.Bus compatibel. FREE SOFTWARE FOR SETTING, READING-OUT SAVING AND ANALYZING T-Logg 160 Product-ID: Humidity- / Temperature- Data-Logger ( meas. values) for any application Starter kit T-Logg 160 SET Product-ID: Complete set with T-Logg 100 and interface converter USB 100 (incl. MINISOFT) Measuring ranges, display ranges: % RH Temperature: C Resolution: 0.1 C / 0.1 % RH Accuracy (at nominal temperature = 25 C): ±3 % in range % Temperature: ± 0.3 C ± * (T - 25 C) Sensors: mounted in sensor tube Sensor tube: approx. Ø 15 mm made of polyamide with screw-type plastic protection cap 10 mm high LCD-display from 4 s... 5 h, freely programmable via software capacity: measuring values each time: 166 days (if interval is 15 min.) Nominal 25 C Working C C CR 2032, exchangeable Battery service over 3 years serial interface, 3-pin miniature integral plug Housing: 48.5 x 48.5 x 35.5 mm (L x W x D) plugs, sensor connection,... are not included, Housing made of shock resistant plastic, transparent front made of polycarbonate. splash water-proof: IP 65. (except filter cap of T-Logg 160). The T-Logg 100 have been manufactured in accordance with the regulations concerning EMC (2004/108/EG). The device meets EN (table 2, class B), additional error: < 0.5 % The T-Logg 100 is not suitable for bus operation and is not E.A.S.Y.Bus compatibel. Temperature probe Transmitter Logger / EASYBus Display / Controller Software: MINISOFT Read-out software for the T-Logg. Further information p.r.t. page 78. the T-Logg can also be controlled by the software GSOFT40K. Accessories and spare parts: USB 100 interface converter, for direct connection of one T-Logg to the USB-interface of a PC. GWH 40K Wall suspension with lock against theft (picture: see page 104) suitable for e.g. T-Logg 100, T-Logg 120 K -... and T-Logg 160. GWH 10 Simple wall suspension, made of stainless steel (picture: see page 104) Mount wall suspension at the monitoring point, logger may now be easily put in. CR 2032 spare battery for T-loggs Alarm / Protection Software information on Logger / EASYBus p.r.t. page

4 Alarm / Protection Temperature probe Transmitter Logger / EASYBus Display / Controller Handheld instrument Temperature Logger for watching production and server-rooms EASYLOG 40K EASYLOG 40K Product-ID: Temperature Data Logger ( meas. values) for any application, sensor tube are attached on the device EASYLOG 40KH Product-ID: Temperature Data Logger ( meas. values) for any application, sensor tube are connected via 1 m cable EASYLOG 40KH-E300 Product-ID: Temperature Data Logger ( meas. values) for any application, tube connected via cable, increased measuring range (0.1 C) EASYLOG 40KH-E600 Product-ID: Temperature Data Logger ( meas. values) for any application, tube connected via cable, increased measuring range (1 C) EASYLOG 40KH-GOF Product-ID: Temperature Data Logger ( meas. values) for any application, with surface probe for pipe mounting Measuring ranges: EASYLOG 40K: C EASYLOG 40KH: C EASYLOG 40KH-E300: C EASYLOG 40KH-E600: C EASYLOG 40KH-GOF: C For special measuring ranges refer to options Working range C (electronic): Resolution display 0.1 C or 1 C and memory: (corresponding type) Accuracy: (at nominal temperature = 25 C) EASYLOG 40K: ±0.5 C EASYLOG 40KH: ±0.5 C EASYLOG 40KH-E300: ±0.5 C ±0.2 % of m.v. EASYLOG 40KH-E600: ±1 C ±0.2 % of m.v. EASYLOG 40KH-GOF: ±0.5 C ±0.2 % of m.v. Sensor: Pt1000 (2-wire) - Design 40K: (refer upper - Design 40KH: (refer upper - Design 40KH-E300: (without sensor tube made of plastic, Ø 7 mm, approx. 30 mm long, attached on the device. ( at certifi cate: stainless steel tube, Ø 5 mm, approx. 60 mm long) sensor tube made of stainless steel, Ø 5 mm, approx. 50 mm long, approx. 1 m silicone cable. Cable with antibuckling glanding to housing. sensor tube made of stainless steel, Ø 3 mm, approx. 100 mm long, sleeve Ø 5 x 50 mm, approx. 1 m glass silk cable. Cable with anti-buckling glanding to housing. DIN EN AS WELL AS COOLING CHAMBERS ACCORDING ASSIGNATION OF FROZEN FOOD 92/1/EWG - Design 40KH-E600: (without - Design 40KH-GOF: (without EASYLOG 40KH sensor tube made of stainless steel, Ø 3 mm, approx. 100 mm long, sleeve Ø 5 x 50 mm, flexible coating-element, approx. 1 m silicone cable. Cable with anti-buckling glanding to housing. self-adhesive surface temperature probe with moulded silicone design (type GOF 115 Pt p.r.t. p. 140), approx. 2 m PFA-insulated cable. Cable with anti-buckling glanding to housing. Special design types upon request 10 mm high LCD-display 2 s... 5 h, free programmable via software GSOFT 40K capacity: measuring values time: 500 days, Battery service approx. 6 years Working temperature (electronic): C C EASYBus-interface, 3-pin mini-integral plug. Needed connection-cable EBSK01 not included in delivery (see accessories page 104) With an according interface converter you can connect 120 logger without having any problems. Housing: 48.5 x 48.5 x 35.5 mm (W x W x D) sensor and plug not included, IP65. Approvals: DIN EN The EASYLOG have been manufactured concerning EMC (2004/108/EG). The device meets EN (table 2, class B) additional error: < 0.5 % double battery capacity recommended for high measurerates additional alarm-output open-collector output via 4-pole miniature mounting connector (IP65) including 1 m cable. Max. switching power: 28 V, 50 ma - AFK: plugable probe-cable, 4-pole (IP65) miniature mounting connector including assembling of the temperature-probe to the corresponding connection socket - SMB: extra measuring range, freely selectable between C. The essential probe-adjustment is not included in this price. at a measuring span <400 C (e.g. ± 200 C) a resolution of 0.1 C is possible. Taller ranges have a resolution of 1 C - WPT3 Certificate of calibration (not available at..40kh-gof) (measuring points: -20 C / 0 C / +60 C (at... 40K) or -20 C / 0 C / +70 C (at... 40KH)) EASYLOG 40IMP/S Product-ID: Pulse Data Logger (48000 measuring values) for individual use (type switching contact - with PG-glanding and cable) EASYLOG 40IMP/T Product-ID: Pulse Data Logger (48000 measuring values) for individual use (type TTL-signal - with PG-glanding and cable) Measuring range: pulses/cycle Resolution: 1 pulse Cycle: 2 s... 5 h, free programmable via software GSOFT 40K Display range: digit free programmable Decimal point: any position Input signals: EASYLOG passive volt-free switching contact 40IMP/S: EASYLOG active TTL-signal 40IMP/T: (input is not isolated for EASYBus) Resolution display and memory: 1 digit Accuracy: cycle time ±50 ms 10 mm high LCD-display equal to cycle capacity: measuring values time: 500 days, Battery service Working approx. 6 years (without switching current, at 15 min) C C EASYBus-interface, 3-pin mini-integral plug. Needed connection-cable EBSK01 not included in delivery (see accessories page 104) Housing: 48.5 x 48.5 x 35.5 mm (L x W x D) plug and cable not included, IP65 Electric connection: Pulse-Logger FOR CONSUMPTION AND FLOW RATE MEASURING, PIECE COUNTING ETC. (for input signals) approx. 0.5 m connection cable, flying leads concerning EMC (2004/108/ EG). The device meets EN (table 2, class B) additional error: < 0.5 % double battery capacity recommended for high measure-rates additional alarm-output, open-collector output via 4-pole miniature mounting connector (IP65) including 1 m cable. Max. switching power: 28 V, 50 ma 100 further informationen on

5 Logger / EASYBus EASYLOG 24RFT EASYLOG 24RFT Product-ID: Humidity-/Temperature-Data-Logger ( measuring values each) for individual use. EASYLOG 24RFT-E Product-ID: Humidity-/Temperature-Data-Logger ( measuring values each) for individual use. Measuring range, Display ranges: % RH Temperature: C Resolution 0.1 C and 0.1 % RH display and memory: Accuracy (at nominal temperature = 25 C): ±3 % in range % Temperature: ±0.5 C Sensors: high-quality capacitive polymer humidity sensor and Pt1000 temperature sensor Sensor tube: EASYLOG 24RFT: approx. Ø 15 mm made of polyamide EASYLOG 24RFT-E: Protection cap: capacity: time: Battery service Working Humidity-/Temperature-Logger approx. Ø 14 x 68 mm made of PVDF, connected to logger via 1 m teflon cable screw-type plastic protection cap for quick responses LCD-display, 10 mm high 4 s... 5 h free programmable via software GSOFT 40K measuring values each channel 500 days, approx. 6 years C C EASYBus-interface 3-pin mini-integral plug. Needed connection-cable EBSK01 not included in delivery (see accessories page 104) With an according interface converter you can connect 120 logger without having any problems. FOR MUSEUMS, GREENHOUSES, MEDICINE TECHNOLOGY ETC. EASYLOG 24RFT-E Housing: 48.5 x 48.5 x 35.5 mm (H x W x D) sensor and plug not included. Housing made of shock resistant plastic, transparent front made of polycarbonate, splash water-proof: IP 65 (excl. protection cap) concerning EMC (2004/108/ EG). The device meets EN (table 2, class B), additional error: < 0.5 % double battery capacity, recommended for high measure-rates additional alarm-output, open-collector output via 4-pole miniature mounting connector (IP65) including 1 m cable. Max. switching power: 28 V, 50 ma - WPF4 Certificate of calibration humidity (measuring points: approx. 20 / 40 / 60 / 80 %) Accessories and spare parts: EBW 1 Level converter for connection of up to 9 EASY- Bus data logger to the RS232-interface of a PC. (Power supply: 230 V/50 Hz) EBW 3 Level converter for connection of one EASYBus data logger to the USB-interface of a PC. (Power supply: via USB) GSOFT 40K incl. EBSK01 (connection cable in scope of supply) Windows software for setting of device, data readout and printing of the stored data. (for further description p.r.t. page 78) EBSK 01 Special connector with approx. 1 m cable for the connection of one EASYLOG. (note: cable is in scope of supply of the software GSOFT 40K Standard Signal Logger EASYLOG 40NS W REPLACES FOR EXPENSIVE RECORDERS Attention: Our software GSOFT40K as well as a level converter (EBW1, EBW3 or EBW64) are required for all EASYLOG devices for configuration and to read-out logger data. (p.r.t. p. 78 and 104) EASYLOG 40NS W -... Standard Signal Data Logger ( meas. values) for transducers etc. (with elbow type plug) EASYLOG 40NS K -... Standard Signal Data Logger ( meas. values) for transducers etc. (with PG glanding and cable) please specify standard signal desired when ordering Display range: digit free programmable Decimal point: any position Input signals: one signal only! 0-2 V, 0-10 V, 0-20 ma or 4-20 ma, other input signals upon request (input is not isolated for EASYBus) Accuracy: ±0.5 % (at nominal temperature) 10 mm high LCD-display 2 s... 5 h free programmable via software GSOFT 40K capacity: measuring values time: 500 days, Battery service approx. 6 years (at 15 min) Working C C EASYBus-interface 3-pin mini-integral plug. Needed connection-cable EBSK01 not included in delivery (see accessories page 104) Housing: 48.5 x 48.5 x 35.5 mm (L x W x D) (with elbow-plug: 50.5 x 90 x 39.5 mm), splash water-proof IP65 Electric connection: (for input signals)... 40NS W: elbow-plug in accordance with EN /A for connection to an existing transmitter NS K: approx. 0.5 m connection cable concerning EMC (2004/108/ EG). The device meets EN (table 2, class B), additional error: < 0.5 % double battery capacity recommended for high measure-rates additional alarm-output open-collector output via 4-pole miniature mounting connector (IP65) including 1 m cable. Max. switching power: 28 V, 50 ma Alarm / Protection Temperature probe Transmitter Logger / EASYBus Display / Controller Handheld instrument Software information on Logger / EASYBus p.r.t. page

6 Alarm / Protection Temperature probe Transmitter Logger / EASYBus Display / Controller Handheld instrument State-Logger EASYLOG 40BIN Product-ID: State Data-Logger (48000 measuring values) for individual use Input signal: passive volt-free switching contact (input is not isolated for EASYBus) Measuring values: Cycle: Resolution display and memory: 1 = contact is closed (R < 50 Ohm) 0 = contact is open (R > 20 kohm) 2 s... 5 h, free programmable via software GSOFT 40K 1 digit 10 mm high LCD-display equal to cycle capacity: measuring values time: 500 days, Battery service Working approx. 6 years (without switching current, if recording interval is 15 min.) C C EASYBus-interface 3-pin mini-integral plug Needed connection-cable EBSK01 not included in delivery (see accessories page 104) With an according interface converter you can connect 120 logger without having any problems. Housing: 48.5 x 48.5 x 35.5 mm (L x W x D) plug and cable not included, IP65 Electric connection: FOR STATE MONITORING ETC. (for input signals) approx. 0.5 m connection cable, fl ying leads concerning EMC (2004/108/ EG). The device meets EN (table 2, class B) additional error: < 0.5 % Optionen: double battery capacity recommended for high measure-rates additional alarm-output open-collector output via 4-pole miniature mounting connector (IP65) including 1 m cable. Max. switching power: 28 V, 50 ma Humidity-/Temperature-/Air pressure Logger FOR CLIMATE MONITORING ETC. Description: The EASYLOG 80CL can be confi gured, started and stopped by its buttons. It is possible to record max. 64 recording sequences (=start/stop processes) with max data sets (humidity/temperature/air pressure). The device can also be confi gured and handled by the comfortable software GSOFT40K. There is the possibility to block the stopping of the logger by the buttons to protect the logger of unauthorised handling. The device supports the display of units relevant for the air conditioning technology: wet bulb temperature, dew point temperature, enthalpy, atmospheric humidity or absolute humidity. The EASYLOG 80CL provides a big variety of additional functions: SeaLevel correction: instead of the barometric air pressure the pressure at sea level can be displayed (input of height above sea level needed). Min-/max- value memory: callable by the buttons, the highest and lowest value since the start (or reset) of the logger is saved here. Min-/max- alarm function: the exceeding of adjustable min-/max- alarm boundaries by the displayed value is monitored. Optional: alarm output for alarm message of the logger available! Measuring range, Display ranges: % RH Temperature: C Air pressure: hpa Additional available display ranges: Wet bulb C Dewpoint C Enthalpy: kj/kg Atmospheric g/kg humidity: Absolute g/cm³ humidity: Resolution display and memory: Accuracy: 0.1 C, 0.1 % RH and 0.1 hpa or 1 digit ± 2 % in range % Temperature: ± 0.3 C ± * (T - 25 C) Air pressure: ± 1.0 hpa (typ., at 0-60 C) HIGHLIGHTS: double display up to 64 recording sequences can be saved big storage for up to measuring values for each unit (humidity, temperature, air pressure,...) = values for all Various additional measurement categories are available: dew point temperature, wet bulb temperature, enthalpy, atmospheric humidity or absolute humidity EASYLOG 80CL Product-ID: Humidity-/Temperature-/Air pressure Data-Logger (each measured values) for climatic applications. Sensors: Humidity/ Temperature: Air pressure: Sensor tube: Protection cap: capacity: time: Battery service Working Attention: Our software GSOFT40K as well as a level converter (EBW1, EBW3 or EBW64) are required for all EASYLOG devices for configuration and to read-out logger data. (p.r.t. p. 78 and 104) sensor mounted in sensor tube (sensor is exchangeable) sensor integrated in housing approx. Ø 15 mm made of polyamide screw-type plastic protection cap for quick responses two 4½-digit LCD-displays 4 s... 5 h, free programmable via buttons on the device or via the software GSOFT 40K data sets (humidity, temperature, air pressure) in max. 64 recording sequences 7 years (at 15 min. interval) approx. 5 years (at 15 min) C C EASYBus-interface 3-pin mini-integral plug. Needed connection-cable EBSK01 not included in delivery (see accessories page 104) With an according interface converter you can connect 60 logger without having any problems. Housing: 48.5 x 48.5 x 35.5 mm (H x W x D) sensor and plug not included. Housing made of shock resistant plastic, transparent front made of polycarbonate, splash water-proof: IP 65 (excl. protection cap) in accordance with the regulations concerning EMC (2004/108/EG). The device meets EN (table 2, class B) additional error: < 0.5 % additional alarm-output open-collector output via 4-pole miniature mounting connector (IP65) including 1 m cable. Max. switching power: 28 V, 50 ma - WPF4 Certifi cate of calibration humidity (measuring points: approx. 20 / 40 / 60 / 80 %) - WPD5 Certifi cate of calibration pressure (measuring points 300 / 500 / 700 / 900 / 1100 hpa) 102 further informationen on

7 Company / GHM brands Logger / EASYBus PRINCIPLE OVERVIEW Characteristics of the EASYBus system Low-cost wiring by using a twisted 2-pin connection line in either bus or tree design (polarity-free); can be used in any combination Bus line for simultaneous power supply and signal transmission Bus length up to 1000 m, extensible by using a repeater Fully automatic start-up installation via software Sensor modules can be changed, removed or added during operation at any time Connection of up to 240 sensor modules Optimum transmission reliability by means of CRC check Bus system is able to process data up to 20 measuring values per second Response time inside the EASYBus-system approx. 1 s; but approx. 20 ms by using a local controlling system E.A.S.Y.Bus System Temperature monitoring and regulation: Cooling chambers Laboratory + utility rooms rooms Relative humidity / dew point / temperature monitoring: rooms, Heating systems / air condition, Museums / exhibition rooms / Libraries, Laboratories / utility rooms Relative humidity / atmospheric pressure, CO 2 monitoring: Manufacturing rooms / storage rooms, Offi ce rooms (to condition the air of the room), Greenhouses Handheld instrument Display / Controller Measurement data acquisition systems for applications ranging from test stands to climate control monitoring Made in Germany CO monitoring: Underground garages / Parking garages Motorcar garage / car repair Indoor go-kart tracks Further information you find in our brochure Measurement data acquisition systems Logger / EASYBus and on EBW 1 EBW 3 EBW 64 EBW 240 according to choice EBW for max. 14 bus loads USB interface converter for max. 2 bus loads for max. 64 bus loads for max. 240 bus loads EASYBus Central data acquisition Display / regulating and monitoring device (4 limit values), without interface converter, max. 20 channels addressable / max. 30 bus loads EB 3000 Option Sensor modules with measured value buffer (logger function) Temperature logger Humidity / temperature logger Air conditioning logger (humidity / temperature / air pressure) EASYBus Sensor modules without measured value buffer Temperature module Humidity / temperature module CO2 module CO module Transmitter Temperature probe Pressure sensor + Standard signal module PC Direct query system Remote query system Alarms Computer with software or PLC Standard signal logger Pulse logger Status logger Any standard signal + Standard signal module Local regulation system For quick regulating times (approx. 20 ms), we recommend local regulation within an EASYBus system (e. g. with GIA 20 EB, GIR 2002, etc.) Alarm / Protection Software information on Logger / EASYBus p.r.t. page

8 Handheld instrument Display / Controller Logger / EASYBus EBW 1 Product-ID: General: for connection of max. 7 EASYBus-modules to the RS232-interface (9-pin Dsub) of your PC. Voltage supply: 230 V AC / 50Hz, 12 / 24 V DC on request Power consumption: approx. 5 W Max. permissible sensor 7 (depending on type of the used sensor modules) modules: Permissible cable length: 200 m (depending on type of cable and wiring) Baud rate: 4800 Baud Serial connection: RS232 Electrical isolated: yes Overload display: no Short-circuit proof: yes (limited: 30 s) Operating C % RH, non-condensing C Dimensions (H x W x D): 112 x 80 x 45 mm Bit-Recovery no Scope of supply: interface converter, 9-pin Dsub extension cable Accessories and spare parts: USB-Adapter for connection of an interface converter to the USB-interface of yout PC GSA 9S-25B connection-adapter: 9-pin Dsub-plug <=> 25-pin Dsub-socket Assessories EBW 64 Product-ID: General: For connection of max. 64 EASYBus-modules to the RS232-interface of your PC. Voltage supply: 230 V AC / 50Hz Power consumption: approx. 15 W Max. permissible sensor 64 (depending on type of the used sensor modules) modules: Permissible cable length: 1000 m (depending on type of cable and wiring) Baud rate: 4800 Baud Serial connection: RS232 Electrical isolated: yes Overload display: yes Short-circuit proof: yes (passiv) Operating C % RH, non-condensing C Dimensions (H x W x D): 100 x 75 x 110 mm Bit-Recovery yes Scope of supply: interface converter, 9-pin Dsub extension cable Accessories and spare parts: USB-Adapter for connection of an interface converter to the USB-interface of yout PC GSA 9S-25B connection-adapter: 9-pin Dsub-plug <=> 25-pin Dsub-socket Transmitter Temperature probe Alarm / Protection EBW 3 Product-ID: General: for connection of one EASYBus-module (e.g. EASYLOG ) to the USBinterface of your PC. (Power supply: via USB) Voltage supply: not necessary Power consumption: max. 0.5 W Max. permissible sensor 1 (depending on type of the used sensor modules) modules: Permissible cable length: 10 m (depending on type of cable and wiring) Baud rate: 4800 Baud Serial connection: USB Electrical isolated: yes Overload display: no Short-circuit proof: no Operating C % RH, non-condensing C Dimensions (H x W x D): 56 x 31 x 24 mm Bit-Recovery no Scope of supply: interface converter GWH 40K GWH 10 LAN 3100 GWH 40K Product-ID: wall suspension with lock as protection against theft suitable for all EASYLOG (except EASYLOG 40NS W), EBN/K -..., GIA0420 and GRA0420 GWH 10 Product-ID: simple wall suspension, made of stainless steel, suitable for all EASYLOG (except EASYLOG 40NS W). LAN 3100 Gigabit Ethernet to USB converter For inquiring EASYBus modules, GMH handheld devices with interface or GDUSB 1000 via network. 2 USB ports for direct connection of EBW 3, USB 3100N or GDUSB 1000 (up to 15 with USB hub). Connection of EBW 1, EBW 64 or EBW 240 via USB adapter (included to scope of delivery) Accessories: power supply unit, USB adapter, operation manual, driver CD EBSK 01 special plug with approx. 1 m of cable for connection of one EASYLOG, EBN... to the EASYBus 104 further informationen on

E.A.S.Y.Bus. Characteristics. Applications. Temperature monitoring and regulating cold storage houses / storage rooms / laboratory+technology.

E.A.S.Y.Bus. Characteristics. Applications. Temperature monitoring and regulating cold storage houses / storage rooms / laboratory+technology. GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 www.ghm-group.de info@ghm-group.de E.A.S.Y.Bus System E.A.S.Y.Bus System Sensor

More information

E.A.S.Y.Bus. GREISINGER electronic GmbH. Measuring Controlling Monitoring Recording. The intelligent, universal and economic solution

E.A.S.Y.Bus. GREISINGER electronic GmbH. Measuring Controlling Monitoring Recording. The intelligent, universal and economic solution GREISINGER electronic GmbH Measuring Controlling Monitoring Recording E.A.S.Y.Bus The intelligent, universal and economic solution GREISINGER electronic GmbH D - 93128 Regenstauf Hans-Sachs-Straße 26 Temperature

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E E39.0.0X.6C-03 Data logger for temperature as of version V1.3 Operating Manual T-Logg 100 T-Logg 100 T-Logg 100 E GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -... E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 E39.0.31.6C-02 Data logger for humidity temperature as of version V1.0 Operating Manual T-Logg 160 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0 +49 (0) 9402

More information

Precision Hand-held Thermometer

Precision Hand-held Thermometer Precision Hand-held Thermometer measuring monitoring analysing Measuring range from -220 C... +1768 C Measuring accuracy starting with ±0.03% MV Large selection of temperature probes PT 100 or thermocouple

More information

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310 High-End Humidity and Temperature Transmitter for Demanding Process Control is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative

More information

Hand-Held Thermometer Model CTH 6200

Hand-Held Thermometer Model CTH 6200 Testing and Calibration Technology Hand-Held Thermometer Model CTH 6200 WIKA Data Sheet CT 51.01 Applications Service industry Measurement and and control laboratories Industry (laboratory, workshop and

More information

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield. Humidity and Temperature Transmitter for High-end Meteorological Applications E33-M is optimized for reliable measurement under demanding weather conditions. Besides accurate measurement of relative humidity

More information

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310 is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative humidity (RH) and temperature (T), the transmitter also calculates parameters

More information

PRESSURE. Handheld instrument. Handheld instrument. Display / Controller. Logger / EASYBus. Transmitter. Temperature probe. Alarm / Protection

PRESSURE. Handheld instrument. Handheld instrument. Display / Controller. Logger / EASYBus. Transmitter. Temperature probe. Alarm / Protection PRESSURE Logger / EASYBus Handheld instrument Display / Controller Application: GMH 5130 GMH 5150 GMH 5155 GMH 3111 GMH 3151 GMH 3156 GMH 3161-12 GMH 3181-12 Relative pressure meas. (over, under- and pressure

More information

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates 1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for

More information

The industrial humidity transmitter

The industrial humidity transmitter The industrial humidity transmitter + probe series testo 661x Optimum adjustment concept thanks to adjustability of the entire signal chain incl. analog adjustment Ethernet, relay and analog outputs allow

More information

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175 We measure it. Next Generation! With the professional Testo data loggers, a new age begins for you Logger series testo 174 Logger series testo 175 Logger series testo 176 testo 174, testo 175, testo 176

More information

Humidity transmitter for critical climate applications

Humidity transmitter for critical climate applications Humidity transmitter for critical climate applications testo 6651 Optimum adjustment concept thanks to adjustability of the entire signal chain incl. analog adjustment Ethernet, relay and analog outputs

More information

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175 We measure it. Next Generation! With the professional Testo data loggers, a new age begins for you Logger series testo 174 Logger series testo 175 Logger series testo 176 We measure it. The right logger

More information

Immersion Temperature Sensors

Immersion Temperature Sensors 1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or

More information

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) Calibratable temperature measuring transducer THERMASGARD with eight switchable measuring ranges, continuous linear output, enclosure

More information

Hand-held thermometer Model CTH6200

Hand-held thermometer Model CTH6200 Calibration technology Hand-held thermometer Model CTH6200 WIKA data sheet CT 51.01 Applications Calibration service companies and service industry Measurement and control laboratories Industry (laboratory,

More information

testo Probe series testo 661x The industrial humidity transmitter We measure it. SPECIFICATIONS testo Probe series testo 661x

testo Probe series testo 661x The industrial humidity transmitter We measure it. SPECIFICATIONS testo Probe series testo 661x + Probe series testo 661x SPECIFICATIONS Optimum adjustment concept thanks to adjustment of the entire signal chain incl. analog adjustment Profibus, Ethernet, relay and analog outputs allow optimum integration

More information

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211 Humidity and Temperature Transmitter for Continuous High Humidity The is dedicated for accurate and long term stable measurement under continuous high humidity (>85 % RH) and condensing conditions in demanding

More information

GMH to 1300 mbar absolute Version 4.7

GMH to 1300 mbar absolute Version 4.7 H31.0.03.6C-09 User s Manual Handheld Digital Vacuum- and Barometer GMH3160-12 0 to 1300 absolute Version 4.7 H31.0.03.6C-09 User s Manual GMH3160-12 page 2 CONTENTS 1 GENERAL...2 1.1 SAFETY REQUIREMENTS...2

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 H20.0.24.6C1-07 EASYBus-Sensor module for humidity temperature with option: selectable humidity display from version V3.2 Operating Manual EBHT 2R / UNI Content 1 INTENDED USE 2 2 GENERAL ADVICE 2 3 SAFETY

More information

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates 1 859 1859P01 1859P02 1859P04 QFA4160 QFA41 D AQF4150 AQF3153 Symaro Room sensors for relative humidity and temperature with calibration certificates QFA41 Operating voltage AC 24 V / DC 13.5...3 Signal

More information

The industrial humidity transmitter

The industrial humidity transmitter The industrial humidity transmitter + probe series testo 661x Optimum adjustment concept thanks to adjustment of the entire signal chain incl. analog adjustment Profibus, Ethernet, relay and analog outputs

More information

ENVIRONMENTAL MONITORING & CONTROL

ENVIRONMENTAL MONITORING & CONTROL ENVIRONMENTAL MONITORING & CONTROL TRANSMITTER DISPLAY METER CONTROLLER in one ProSens is a new line of modern industrial devices, which integrates transmitters, displays, meters and controllers functionalities.

More information

Next Generation! Committing to the future. With the professional Testo data loggers, a new age begins for you. Logger series testo 174

Next Generation! Committing to the future. With the professional Testo data loggers, a new age begins for you. Logger series testo 174 Committing to the future Next Generation! With the professional Testo data loggers, a new age begins for you Logger series testo 174 Logger series testo 175 Logger series testo 176 The new generation of

More information

PI 500 Hand-held instrument for industry

PI 500 Hand-held instrument for industry PI 500 Hand-held instrument for industry The new PI 500 is an all-purpose hand-held measuring instrument for many applications in industry like e. g.: Flow measurement Pressure/vacuum measurement Temperature

More information

ProcessCalibrator Model CPH6000

ProcessCalibrator Model CPH6000 Calibration technology ProcessCalibrator Model CPH6000 WIKA data sheet CT 15.01 Applications Calibration service companies/service industry Maintenance facilities Measurement and control laboratories Quality

More information

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B. Series The precise and reliable measurement of humidity in industrial processes is gaining more and more importance. The multifunctional transmitters series offer the ideal solution. The result of many

More information

PTU300 Combined Pressure, Humidity and Temperature Transmitter

PTU300 Combined Pressure, Humidity and Temperature Transmitter PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface

More information

DMT345 and DMT346 Dewpoint Transmitters

DMT345 and DMT346 Dewpoint Transmitters DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662

More information

Hand-held thermometer Model CTH6200

Hand-held thermometer Model CTH6200 Calibration technology Hand-held thermometer Model CTH6200 WIKA data sheet CT 51.01 for further approvals see page 3 Applications Calibration service companies and service industry Measurement and control

More information

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers Product highlights 3-A fulfillment without elastomers Front-flush or immersed types Accurate reading independent on ambient temperature Fast response time Hermetically sealed towards process Capable of

More information

Operating Manual Digital Quick Response Thermometer GMH 3210 For Thermocouple Probes Type J, K, N, S, T from Version 1.0

Operating Manual Digital Quick Response Thermometer GMH 3210 For Thermocouple Probes Type J, K, N, S, T from Version 1.0 H54.0.01.6C-02 Operating Manual Digital Quick Response Thermometer GMH 3210 For Thermocouple Probes Type J, K, N, S, T from Version 1.0 1 IN GENERAL... 1 1.1 SAFETY INSTRUCTIONS... 1 1.2 HOW TO OPERATE

More information

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KMF 720 Constant climate chambers with expanded temperature / humidity range Model KMF 720 Constant climate chambers with expanded temperature / humidity range The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this constant

More information

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34) is dedicated for reliable monitoring of lubrication, hydraulic and insulation oils as well as diesel fuel. In addition to highly accurate measurement of water activity (a w ) and temperature (T), calculates

More information

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210 Humidity and Temperature Transmitter for Demanding Climate Control The transmitter by E+E Elektronik meets the highest requirements in demanding climate control applications. Besides the accurate measurement

More information

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values Technical Information Minilog RDL10 Measured value collector with 2 input channels for storing analog and digital values Application Data storage for termperature, humidity, pressure, flow, level, and

More information

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated

More information

Measurement data monitoring system

Measurement data monitoring system Data sheet testo Saveris Measurement data monitoring system testo Saveris Automated and uninterrupted measurement data recording Flexible system set-up with wireless or Ethernet probes in many probe versions

More information

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Front View KEY FEATURES SIL1 / IEC 61508:2010 compliant Dual Channel Speed and Ratio Monitor with

More information

Measurement data monitoring system

Measurement data monitoring system We measure it. Measurement data monitoring system testo Saveris Automated and uninterrupted measurement data recording Flexible system set-up with wireless or Ethernet probes in many probe versions C %RH

More information

WiFi data logger system

WiFi data logger system WiFi data logger system Saveris 2 temperature and humidity monitoring re-thought Data transfer by WiFi All measurement data always available, anywhere, on any instrument C %RH Alarms when limit values

More information

CAEL-DP Series Dew Point Transmitter for Industrial Control

CAEL-DP Series Dew Point Transmitter for Industrial Control CAEL-DP Series Dew Point Transmitter for Industrial Control SERIAL's latest CAEL series Dew Point transmitter meets the harsh environmental requirements for Dew Point measurement. Via temperature and relative

More information

Stand-Alone, Low-Cost Data Loggers and Accessories. USB-500/600 Series Comparison Chart

Stand-Alone, Low-Cost Data Loggers and Accessories. USB-500/600 Series Comparison Chart Stand-Alone, Low-Cost Data Loggers and Accessories Features Stand-alone remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels

More information

Display GTH2448/1. Controller GIR SW GIR 2002 PID GIR 2002

Display GTH2448/1. Controller GIR SW GIR 2002 PID GIR 2002 3.G.01.130-E-140714 page 1/16 Display Application: Device GIA... N GIA... N - ex Dimensions 24 x 48 24 x 48 24 x 48 24 x 48 24 x 48 24 x 48 48 x 96 GIA 2448 GTH2448/1 Measuring input normalized signal

More information

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low

More information

Millenium II +: general characteristics

Millenium II +: general characteristics Millenium II +: general characteristics Starter kit Blind Temperature sensors Special starter kits Bare board Power supply Level detection Local extensions Accessories Standard Expandable Adjacent extensions

More information

ENVIRONMENTAL MONITORING & CONTROL

ENVIRONMENTAL MONITORING & CONTROL ENVIRONMENTAL MONITORING & CONTROL TRANSMITTER DISPLAY METER CONTROLLER in one ProSens is a new series of modern industrial devices, which integrates sensors, converters, meters and controllers functionalities.

More information

Hand-Held Pressure Indicator Model CPH6200-S1 Model CPH6200-S2 (2-channel version)

Hand-Held Pressure Indicator Model CPH6200-S1 Model CPH6200-S2 (2-channel version) Testing and Calibration Technology Hand-Held Pressure Indicator Model CPH6200-S1 Model CPH6200-S2 (2-channel version) WIKA Data Sheet CT 11.01 Applications Calibration service companies/service industry

More information

2YL-T15-4M & 2YL-T16-4M Thermocouple Loggers. 2YL-M36-4M & 2YL-M37-4M Multi Terminal Input Loggers. 2YL-M61-4M & 2YL-M62-4M Lux Loggers

2YL-T15-4M & 2YL-T16-4M Thermocouple Loggers. 2YL-M36-4M & 2YL-M37-4M Multi Terminal Input Loggers. 2YL-M61-4M & 2YL-M62-4M Lux Loggers 6 Yoyo Data Loggers 2YL-T10-4M & 2YL-T10E-4M Temperature Loggers 2YL-T11-4M & 2YL-12-4M Multi Loggers 2YL-T15-4M & 2YL-T16-4M Thermocouple Loggers 2YL-T14-4M, 2YL-T14E-4M, 2YL-RH24-4M & 2YL-RH24E-4M PEEK

More information

F %RH. %rf CO 2. g/m 3. inch H₂O. hpa. Measure. Record. Monitor. Choose the right data loggers for your application now.

F %RH. %rf CO 2. g/m 3. inch H₂O. hpa. Measure. Record. Monitor. Choose the right data loggers for your application now. F %RH g C %rf CO 2 g/m 3 hpa inch H₂O td Measure. Record. Monitor. Choose the right for your application now. 1 You know your requirements - we have the right. How do you want to record your measurement?

More information

Hand-Held Pressure Indicator

Hand-Held Pressure Indicator Hand-Held Pressure Indicator Model CPH 6200 Model CPH 6200-S2 (2-channel version) Model CPH 62I0 (intrinsically safe version) WIKA Data Sheet CT 11.01 Applications Calibration service companies / service

More information

Precision hand-held pressure indicator Model CPH6400

Precision hand-held pressure indicator Model CPH6400 Calibration technology Precision hand-held pressure indicator Model CPH6400 WIKA data sheet CT 14.01 Applications Calibration service companies and service industry Measurement and control laboratories

More information

Portable Multi-Function Calibrator Model CEP6000

Portable Multi-Function Calibrator Model CEP6000 Calibration Technology Portable Multi-Function Calibrator Model CEP6000 WIKA Data Sheet CT 83.01 Applications Calibration service companies/service industry Instrument and control workshops Industry (Laboratories,

More information

MEASURING AND TESTING INSTRUMENTS

MEASURING AND TESTING INSTRUMENTS MEASURING AND TESTING INSTRUMENTS Whether measuring temperature, current or voltage testing the right measuring tool can facilitate the everyday work. If one wants to perform several measuring tasks at

More information

Multi-range pressure and differential pressure transmitter

Multi-range pressure and differential pressure transmitter Page 1/6 Multi-range pressure and differential pressure transmitter Type 402005 Applications Ventilation Air conditioning Clean-room technology Flue draft mechanisms Filter monitoring Brief description

More information

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Product Selection Guide Industrial Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Laboratory and Field Benchtop Meters 5 Field Meters 5 Benchtop Controllers 7 Pocket Meters & Testers 9 Accessories

More information

JUMO TDA-300 and JUMO TDA-3000 Handheld Thermometer with data logger

JUMO TDA-300 and JUMO TDA-3000 Handheld Thermometer with data logger JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Supplied with. Calibration certificate. HD 200 Hygrometer

Supplied with. Calibration certificate. HD 200 Hygrometer Supplied with Calibration certificate HD 200 Hygrometer Table of contents 3 I Technical specifications...4 Technical features......4 Specifications......4 II Introduction......5 Description......5 Connections......6

More information

Data logger systems from ROTRONIC

Data logger systems from ROTRONIC Data logger systems from ROTRONIC RS-485 Logger, power supply via RS-485 network RS-485 Logger, power supply via RS-485 network RS-485 Logger, power supply via RS-485 network Logger with power supply RS-485

More information

ph electrodes ph C ph C

ph electrodes ph C ph C PH / REDOX / O 2 dissolved Logger / EASYBus Display / Controller Transmitter ph / Redox GMH 5530 GMH 5550 GMH 3511 Waters measuring, fish-keeping, aquafarming Drinking water-, process monitoring, ground

More information

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature Page 1/7 JUMO ecotrans 03 Microprocessor transmitter/ switching device for /Redox voltage and temperature with a 2-line LCD for mounting on a 35 mm DIN rail Brief description Depending on the configuration,

More information

Precision digital measuring device PHYSICS 51

Precision digital measuring device PHYSICS 51 Precision digital measuring device PHYSICS 51 Digital measuring device for thermocouples, NTC resistance thermometers, infrared temperature probes, capacitive humidity probes. Technical data PHYSICS 51

More information

PCD DIGITAL Differential pressure probe

PCD DIGITAL Differential pressure probe Differential pressure probe 2016 ROTRONIC AG Bassersdorf Switzerland Contents 1 Overview... 3 1.1 Hardware and software compatibility... 3 2 Variants... 4 3 General information... 6 3.1 Power supply...

More information

ProcessCalibrator Model CPH6000

ProcessCalibrator Model CPH6000 Calibration technology ProcessCalibrator Model CPH6000 WIKA data sheet CT 15.01 Applications Calibration service companies/service industry Maintenance facilities Measurement and control laboratories Quality

More information

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured values.

More information

EE32/33 Series. Humidity / Temperature Transmitter for High Humidity and Chemical Applications. Typical Applications. Features

EE32/33 Series. Humidity / Temperature Transmitter for High Humidity and Chemical Applications. Typical Applications. Features EE32/33 Series Humidity / Temperature Transmitter for High Humidity and Chemical Applications The highly accurate EE32/33 series are designed for fast and reliable measurement of relative humidity / dew

More information

TR-7 Series. Network / USB Data Loggers TR-7wf/nw Series Infrared / USB Data Loggers. TR-7Ui Series

TR-7 Series. Network / USB Data Loggers TR-7wf/nw Series Infrared / USB Data Loggers. TR-7Ui Series TR-7 Series Network / USB Data Loggers TR-7wf/nw Series Infrared / USB Data Loggers TR-7Ui Series TR-7wf/nw Series Next Generation Data LoggersT&D Cloud Service Free of Charge! Automatic Data Upload Access

More information

Multi-functional precision thermometer CTR3000

Multi-functional precision thermometer CTR3000 Calibration technology Multi-functional precision thermometer CTR3000 WIKA data sheet CT 60.15 Applications Pharmaceutical industry Industry (laboratory, workshop and production) Temperature sensor and

More information

Measurement data monitoring system

Measurement data monitoring system We measure it. Measurement data monitoring system testo Saveris Automated and uninterrupted measurement data recording C Stationary and mobile data monitoring in one system Flexible system set-up with

More information

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual T0210 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual Instruction manual for use of T0210 transmitter

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Easy Analog RNB130. Technical Information. Primary switched-mode power supply Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power

More information

Additional functions of the GMH3750:

Additional functions of the GMH3750: Product overview Service Calibration, DKD 4 HANDHELD INSTRUMENTS (with sensors and accessories) Temperature 5-11 Oxygen 30-31, 39 Air humidity 12-15 Conductivity 32-33 Flow, Anemometer 12-13, 40 ph, redox

More information

Environmental Conditions C - remote sensing probe up to 120 C (248 F)

Environmental Conditions C - remote sensing probe up to 120 C (248 F) EE33 Humidity / Temperature Transmitter for High Humidity and Chemical Applications The highly accurate EE33 series are designed for fast and reliable measurement of relative humidity / dew point temperature

More information

testostor 171 Instruction manual

testostor 171 Instruction manual testostor 171 Instruction manual en Contents Important information...4 Description...5 Connection instructions...7 Technical data...8 Requirements...12 Making backup copies...12 On the job... Installation...12

More information

MID approval no. DE-08-MI004-PTB004 Date of release

MID approval no. DE-08-MI004-PTB004 Date of release 1. Identification Energy and Flow Computer Flow rate and energy calculator for liquids, gases and water steam E-DB-1000-700-01 MID approval no. DE-08-MI004-PTB004 Date of release 04.01.08 2. Area of Application

More information

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual LOGGER S0541 Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual Instruction Manual for use of S0541 logger Instrument is designed for measurement and record of temperature

More information

Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual TRANSMITTER T3413, T3417 Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual Instruction Manual for use of temperature

More information

USER S GUIDE. EE211 - Heatead Humidity and Temperature Transmitter for High Humidity Applications GENERAL ASSEMBLY SCOPE OF SUPPLY CAUTION

USER S GUIDE. EE211 - Heatead Humidity and Temperature Transmitter for High Humidity Applications GENERAL ASSEMBLY SCOPE OF SUPPLY CAUTION USER S GUIDE EE211 - Heatead Humidity and Temperature Transmitter for High Humidity Applications GENERAL The EE211 is dedicated for accurate, long term stable measurement under high humidity and condensing

More information

Advantages high measuring dynamics Nv (up to 1 : 1000) measuring range from 0.2 m/s. low measuring uncertainty, even at lowest flow velocities

Advantages high measuring dynamics Nv (up to 1 : 1000) measuring range from 0.2 m/s. low measuring uncertainty, even at lowest flow velocities M E E T I N S T R U M E N T A T I E Turfschipper 114 2292 JB Wateringen Tel. 0174 272330 Fax. 0174 272340 info@catec.nl www.catec.nl Drawing 2b Sensor TA10... ZG2b with integrated transducer U10a/U10M

More information

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL 1 2 CONTENTS 1. APPLICATION... 5 2. BASIC REQUIREMENTS, OPERATIONAL SAFETY... 5 3. INSTALLATION... 5 3.1. Assembly...5 3.2. Electrical Connections...7

More information

EBI 3x0 USB Data Loggers

EBI 3x0 USB Data Loggers 60 EBI 3x0 USB Data Loggers Cold Chain Monitoring The easy to use data loggers with USB connection monitor the and/or humidity during transport and storage of sensitive goods like medicine, food, serums

More information

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4. CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. 4. Relays Power supply 2. Relays 8. Universal Inputs/ Process Bus (KNX) RS485 (Modbus) Tool (USB) Ethernet Tool (USB)/

More information

Miles Ahead of the Competition!

Miles Ahead of the Competition! 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com We measure it. Miles Ahead of the Competition! testo data loggers 174, 175 & 176

More information

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane Filter Caps for Humidity and Dewpoint Transmitters with probe 12 mm (0.47 ) The right choice of appropriate filter cap is essential for best long term performance in the application. For assistance please

More information

Class 220 KISTOCK. KT 220, KH 220 and KTT 220

Class 220 KISTOCK. KT 220, KH 220 and KTT 220 Class 220 KISTOCK KT 220, KH 220 and KTT 220 Table of contents 1 Safety instructions...4 1.1 Precautions for use...4 1.2 Symbols used...4 2 Presentation of the device...5 2.1 Use...5 2.2 Applications...5

More information

testo 176 Data loggers

testo 176 Data loggers 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo 176 Data loggers Instruction manual 1 Contents 1 Contents 1 Contents...31

More information

Controller. Applications. Characteristics. Extruder machines Heating control systems Facility engineering Wide range of instrumentation

Controller. Applications. Characteristics. Extruder machines Heating control systems Facility engineering Wide range of instrumentation GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Controller Characteristics System Output Case 2-point-controller, 3-point-controller,

More information

Hygro-/Thermometer. Operating Manual GFTH 95

Hygro-/Thermometer. Operating Manual GFTH 95 H53.0.X1.6C-07 Hygro-/Thermometer Operating Manual GFTH 95 WEEE-Reg.-No. DE93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0 +49 (0) 9402 / 9383-33

More information

Operating Instructions

Operating Instructions Operating Instructions t i SPAN NOT USED - - 4...20mA DISPLAY t i SPAN END POINT DISPLAY Ð - 4...20mA p Safety information, Note Ex area Safety information Please read this manual carefully, and also take

More information

Sensor for car parks and tunnels

Sensor for car parks and tunnels Page 1 Sep. 2017 system with exchangeable sensor element including digital value processing, temperature compensation and selfmonitoring algorithm for the continuous sensing and control of the ambient

More information

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W Duct Sensor Humidity / Temperature For measuring the relative or absolute humidity and temperature in duct applications. The measured values and absolute humidity, dewpoint and enthalpy are transmitted

More information

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track Electronic multiturn gear with intelligent sensing technology (IST) Integrative Technology Max. 4 programmable outputs* for the SSI version Programmable parameters include*: code type, resolution per revolution,

More information

Intrinsically safe Hand-Held Pressure Indicator (ATEX-version) Model CPH62I0

Intrinsically safe Hand-Held Pressure Indicator (ATEX-version) Model CPH62I0 Testing and Calibration Technology Intrinsically safe Hand-Held Pressure Indicator (ATEX-version) Model CPH62I0 WIKA Data Sheet CT 11.02 Applications Calibration service companies/service industry Instrument

More information

EBI 3x0 USB Data Loggers

EBI 3x0 USB Data Loggers 60 Cold Chain and Process Monitoring EBI 3x0 USB Data Loggers EBI 3x0 USB Data Loggers Cold Chain Monitoring The easy to use data loggers with USB connection monitor the and/or humidity during transport

More information

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773 APPLICATION Static compact energy meter using ultrasonic technology Highly accurate recording of all billing data in local and district heating and cooling systems FEATURES 1st. approval in Europe for

More information

We measure it. Everything under control: With testo Saveris TM, measurement data are under control everywhere.

We measure it. Everything under control: With testo Saveris TM, measurement data are under control everywhere. We measure it. Everything under control: With testo Saveris TM, measurement data are under control everywhere. Saveris testo Saveris TM : Easy, safe and efficient measurement data monitoring The data monitoring

More information