1 Slide 1 Oracle <Insert Picture Here>

2 Slide 2 <Insert Picture Here> WZT-6509 version B Sun Fire Nehalem and Westmere Rack-Mount Server Installation and Replacement Welcome to the installation and replacement module. This content will cover the installation and replacement procedures of the X2270, X4170, X4270 and X4275 rack-mount servers and their M2 models.

3 Slide 3 Objectives Prepare the server for installation Prepare the server for component replacement Name the key steps of replacing the server or its components 3 Upon completion of this module, you should be able to: 1 Prepare the server for installation 2 Prepare the server for component replacement and 3 Name the key steps of replacing the server or its components

4 Slide 4 Additional Resources Sun Microsystems, Inc., Sun Fire X2270 Server Service Manual, Revision A, March 2009 Part Number xx. Sun Microsystems, Inc., Sun Fire X4170, X4270 and X4275 Servers Service Manual, Revision A, March 2009 Part Number xx. Sun Microsystems, Inc., Sun Fire X4170, X4270 and X4275 Servers Installation Guide, Revision A, March 2009, Part Number xx. Sun Microsystems, Inc., Sun Fire X4170, X4270 and X4275 Servers Solaris and Linux OS Installation Guide, Revision A, March 2009, Part Number xx. Sun Microsystems, Inc., Sun Fire X4170, X4270 and X4275 Servers Windows OS Installation Guide, Revision A, March 2009, Part Number xx. Press PLAY (4) to Continue 4 The following references provide additional information on the servers and their components. 1

5 Slide 5 Additional Resources Sun Microsystems, Inc., Sun Fire X2270 M2 Server Service Manual, Revision A, April 2010, Part Number xx. Sun Microsystems, Inc., Sun Fire X4170 M2 Servers Service Manual, Revision A, April 2010, Part Number xx. Sun Microsystems, Inc., Sun Fire X4270 M2 Servers Service Manual, Revision A, April 2010, Part Number xx Sun Microsystems, Inc., Sun Fire X4170 and X4270 M2 Servers Installation Guide, Revision A, April 2010, Part Number xx Sun Microsystems, Inc., Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for Sun Fire X4170 M2 and X4270 M2 Servers, Revision A, April 2010, Part Number xx Press PLAY (4) to Continue 5 The following references provide additional information on the M2 servers and their components 1 along with the links to the TOI presentations that served as the source information for this module. 2

6 Slide 6 1U Rack Mount Server Configurations Sun Fire X2270 and X2270 M2Server 1U Sun Fire X4170 and X4170 M2Server Sun Fire X4270 and X4270 M2Server 2U Sun Fire X4275 and X4275 M2 Server 2U Press PLAY (4) to Continue 6 This presentation will cover the installation and replacement procedures for the rack mount servers displayed here and their replaceable components. Any procedures that apply to a specific model or models will be noted in the presentation. 1

7 Slide 7 Rack Mounting the Server Key installation steps: Step 1: Inventory the components Dongle cable and adapter Rack mount server Rack mount Kit Getting Started Documentation Press PLAY (4) to Continue 7 Once you unpack the rack mount server, do an inventory to verify you have all the components listed here before you start any other tasks. 1

8 Slide 8 Rack Mounting the Server Key installation steps: Step 2. Register the server serial number on: Step 3. Install the optional components Step 4. Install rack mount kit Step 5. Install the rack mount server Step 6. Cable the power and data cables on the rack mount server CAUTION: For any unit that exceeds 60 lbs, consider using a mechanical lift or multiple personnel to lift the unit. NOTE: For the specific steps these procedures refer to: Service Manual for the X2270 and X4x7x and M2 models Installation Manual for the X2270 and X4x7x and M2 models Press PLAY (4) to Continue 8 Once all the components are accounted for, make sure you register the server serial number on the website listed here. 1 The next step is to install any optional components in the server, that were shipped separately. 2 The following step is to install the rack mount kit on the rack and on the sides of the server. 3 You can now mount the rack mount server 4 and connect its cables. 5 Caution, for any unit that exceeds 60 lbs, consider using a mechanical lift or multiple personnel to lift the unit. 6 Note, for the specific steps for these procedures refer to the documents listed here. 7

9 Slide 9 Replacing the HDDs and SSDs (X2270/X2270 M2) 9 If you are replacing an hard disk drive on the X2270 or X2270 M2 server all you need to do is 1 to push on the HDD handle button to pop out the handle then use the handle to pull the HDD out of its slot. 2 To install a replacement HDD, just slide the HDD into the open slot until it engages the disk backplane connector then secure the it to the slot by locking the handle against the front faceplate of the HDD.

10 Slide 10 Replacing the HDDs and SSDs (X4x7x/X4x7x M2) NOTE: This procedure is the same on any HDD or SSD on a X4170, X4270 or X4275 server or its M2 models Press PLAY (4) to Continue 10 On the X4170, X4270 and X4275 servers and the M2 models, after identifying the HDD or SSD to replace, 1 push on the disk handle button to pop the handle 2 and use the handle to remove the drive. 3 Following the opposite procedure, install the replacement disk and finish the installation by locking the disk drive handle against the drive. 4 Note, this procedure is the same on any HDD or SSD on these servers. Click on the attachment tab and select HDD Configurations Rules Table for these servers. 6

11 Slide 11 Replacing the Power Supplies (X4x7x/X4x7x M2) X4170 / X4170 M2 X427x / X427x M2 Can be HOT SWAPPED 11 The power supplies of all the servers, except for the X2270 and X2270 M2, can be hot swapped without disturbing the operation of the server if the redundant power supply is functioning. 1 The power supplies support a green Power OK LED, an amber Service Action Required LED and a green AC OK LED from top to bottom on the X4270, X4275 servers and their M2 models. 2 The X4170 and X4170 M2 servers have the same LEDs arranged in the opposite direction, from bottom to top. 3 To remove X4170 power supply you first need to release the cable management arm, if present. Then make sure that the redundant power supply is functional before unlatching and pulling the failed power supply out of its slot using its front handle. 4 The X4270 server has a sight difference in the handle lock, as you can see. 5 To replace the power supply, slide the replacement power supply into the open slot until it engages its slot connector and is flush with the chassis. Remember to re-engage the cable management arm.

12 Slide 12 Replacing Server Top Cover (X2270 / X2270 M2) NOTE: Before handling any of the internal components make sure that have an antistatic strap on for proper grounding. 12 After removing the X2270 or X2270 M2 server from the rack and placing it on an anti-static mat, you need to remove its top cover to access the internal components. To remove the top cover loosen the holding screw then just lift off its cover vertically. 1 Note, before handling any of the internal components, make sure that have an anti-static strap on for proper grounding.

13 Slide 13 Replacing Server Top Cover (X4170 / X4170 M2) NOTE: Before handling any of the internal components make sure that have an anti-static strap on for proper grounding. 13 After removing the X4170 or the X4170 M2 server from the rack and placing it on an anti-static mat, you need to remove its top cover to access its internal components. To remove the top cover 1 you need to unlatch the fan module door, 2 press the top cover release button 3 then lift the cover vertically off the server. 4 Note, before handling any of the internal components make sure that have an anti-static strap on for proper grounding.

14 Slide 14 Replacing Server Top Cover (X427x / X427x M2) NOTE: Before handling any of the internal components make sure that have an anti-static strap on for proper grounding. 14 After removing the X4270 or X4275 server or an M2 model from the rack and placing it on an anti-static mat, you need to remove its top cover to access its internal components. To remove the top cover 1 you need to unlatch the fan module door, 2 release the top cover by moving the green latch to the leftmost position 3 then slide the cover to the back of the server 4 and lift the cover vertically off the server. 5 Note, before handling any of the internal components make sure that have an anti-static strap on for proper grounding.

15 Slide 15 Replacing the Power Supply (X2270 / X2270 M2) 15 The replacement of the X2270 and X2270 M2 server power supply requires the server powered down, removed from its slot and placed on an anti-static mat with its cover removed. The power supply removal process requires 1 the three power supply cables disconnected from the motherboard, with the disk drive power cable disconnected and threaded out of the chassis metal cutout. 2 Then with the removal of the mounting screw, you can lift the power supply out of the chassis. 3 The installation of the replacement power supply uses the opposite procedure making sure that all three cables are routed and connected properly and that the mounting screw is replaced.

16 Slide 16 Replacing the Blowers (X2270 / X2270 M2) 16 The blowers on the X2270 and X2270 M2 servers can be replaced 1 by simply disconnecting the power cable 2 and lifting the blower vertically our of the chassis while making sure that the cable does not get caught within the chassis metal cutout. 3 To replace the blower just thread the replacement s cable through the metal cutout on the chassis, connect the power cable and then install the blower in the open slot.

17 Slide 17 Replacing the Fan Module (X4170 / X4170 M2) X4170 X4170 M2 17 Each fan module on the X4170 server has two LEDs located on top of each fan module. 1 One amber Service Action Required LED that lights when either of the fan pair have failed and one green Power OK LED that is lit when the fans are operating correctly. The X4170 M2 server, on the other hand, 2 has one bi-color LED that can display either an amber or green color. 3 In either case, to replace the fan module just lift the fan module vertically out of its slot. Note, X4170 M2 server has a latch that you need to release. 4 To install a replacement just slide a replacement module vertically into the open slot.

18 Slide 18 Replacing the Fans (X427x / X427x M2) X4270 M2 X Each fan module on the X4270 and X4275 servers have two LEDs located on top of each fan module. 1 One amber Service Action Required LED that lights when either of the fan pair have failed and one green Power OK LED that is lit when the fans are operating correctly. The X4270 M2 and X4275 M2 servers, on the other hand, 2 have one bi-color LED per fan model that can display either an amber or green color. These LEDs are located on the edge of the chassis as you see here. 3 In either case, to remove the fan module just lift the fan module vertically out of its slot. 4 To install a replacement just slide a replacement module vertically into the open slot.

19 Slide 19 Replacing the Air Duct (X2270 / X2270 M2) 19 The X2270 and X2270 M2 servers have an air duct that routes the cool air over the CPUs and DIMMs and out the rear of the server. This air duct can be removed by lifting it off the motherboard to access the components like the CPUs and DIMMs that are underneath. 1 Replacement is just as easy, just lay it back on the motherboard as you see here.

20 Slide 20 Replacing the Air Baffle (X427x) NOTE: The X4270 M2 and X4275 M2 do not have air baffles. 20 The X4270 and X4275 servers have an air baffle that routes the cool air over the CPUs and DIMMs and out the rear of the server blade. 1 This air baffle can be removed by pressing the air baffle connectors outward and lifting it off the motherboard to access the components like the CPUs and DIMMs that are underneath. Replacement is just as easy, just engage it to the motherboard as you see here. 2 Note, the X4270 M2 and X4275 M2 do not have air baffles.

21 Slide 21 Locations of Memory DIMMs (X2270 / X2270 M2) CPU0 NOTE: There is no fault remind button on the X2270 or X2270 M2 server and the DIMM and CPU amber fault LEDs are controlled by ILOM. CPU1 21 After removing the top cover of the X2270 or X2270 M2 server blade, you can see 6 memory DIMM slots associated with each CPU. A failed DIMM may be identified within an error message which contains a CPU and DIMM slot number. Notice that DIMM slot D0 is closest to the CPU it corresponds to. 1 Note, there is no fault remind button on the X2270 or X2270 M2 server and the DIMM and CPU amber fault LEDs are controlled by ILOM.

22 Slide 22 Locations of Memory DIMMs (X4x7x / X4x7x M2) NOTE: DIMM slot D0 is closest to the CPU it corresponds to and that each set of 3 DIMM slots corresponds to memory channel. 22 After removing the top cover of the X4170, X4270 or X4275 server or any of the M2 models, you can see 9 memory DIMM slots associated with each CPU. A failed DIMM may be identified within an error message by the CPU and DIMM slot number or by pressing the fault remind button to see which DIMM fault LED displays. 1 Note, DIMM slot D0 is closest to the CPU it corresponds to and each set of 3 DIMM slots corresponds to memory channel.

23 Slide 23 Replacing a Memory DIMM (X2270 / X2270 M2) CPU1 CPU0 Press PLAY (4) to Continue 23 When you go to replace a failed DIMM or add new DIMMs, make sure you follow the DIMM population rules to avoid configuring the memory incorrectly and to maintain the highest possible performance. Once this slide completes, select the X2270 DIMM Population Rules entry on the attachments tab to view the correct method of populating the memory. 1 To remove a DIMM push down on the two side handles to disengage the DIMM then lift it out of its socket. 2 Reverse the process to install a replacement DIMM making sure the side handles lock the DIMM into the socket. 3

24 Slide 24 Replacing a Memory DIMM (X4x7x / X4x7x M2) Press PLAY (4) to Continue 24 On the X4170, X4270, X4275 servers or any of the M2 models, when you go to replace the failed DIMM or add new DIMMs, make sure you follow the DIMM population rules to avoid configuring the memory incorrectly and to maintain the highest possible performance. Once this slide completes, select X4x7x DIMM Population Rules entry to view the correct method of populating the memory. 1 To remove a DIMM push down on the two side handles to disengage the DIMM then lift it out of its socket. 2 Reverse the process to install a replacement DIMM making sure the side handles lock the DIMM into the socket. 3

25 Slide 25 Replacing a CPU (X2270, X4x7x and M2 models) NOTE: The X2270 server has four heat sink screws while the other servers have only two. 25 This CPU replacement procedure applies to all the server models so we are using the X4170 server diagrams as an example. 1 The first step is to make sure you are replacing the correct CPU by confirming the CPU ID in the error message or pressing the fault remind button and to see which CPU fault LED lights. 2 Now using a Phillips #2 screwdriver, remove the heat sink s two screws and springs then twist the heat sink slightly to break the adhesion before removing the heat sink. 3 Unlock the socket cover and open the cover so that you can remove the CPU. 4 Note, the X2270 server has four heat sink screws while the other servers have only two.

26 Slide 26 Replacing a CPU (X2270, X4x7x and M2 models) 26 Now, align and install the replacement CPU in the socket, then install the CPU in the socket 1 and secure it by closing the socket cover over the CPU and locking it using the socket lever. Remember to apply the thermal grease in as an X on top of the CPU before 2 you replace the heat sink and tighten the heat sink screws.

27 Slide 27 Replacing the SP Module (X2270 and X2270 M2) 27 The service processor module is an optional card, on the X2270 and X2270 M2 servers, that contains the server management hardware and software. To access the card, the air duct needs to be removed from the chassis and SP cables need to disconnected from the SP card. 1 To remove the SP card, loosen the holding screw 2 then disengage its motherboard connector by lifting the card up. Make sure to slide the card forward before lifting it out of the chassis. 3 To install the SP card, first install the alignment pin on the screw hole then install the card, making sure that the card s connectors are oriented towards the rear chassis openings. Finally, secure the card by tightening the holding screw.

28 Slide 28 Replacing the RTC Battery (X2270, X4x7x and M2 models) X2270 CR2032 X2270 M2 CR2032 X4x7x and X4x7x M2 CR Every server covered in this presentation has a real time clock that is used to maintain the system clock running when the server is not powered. The differences are in the location of the RTC battery and whether the battery stands vertically or lays flat on the motherboard. 1 The vertical real time clock battery can be removed by pushing the disc away from the socket wall and against the metal lead then lifting it vertically out of the socket. 2 The horizontal real time clock battery can be removed by pulling then quickly releasing the battery retaining click to pop the battery out if its socket, then just lift the battery out of the socket. 3 The installation of the RTC battery is performed by orienting the disc s positive side away from the socket back wall while the disc is slid vertically or placed horizontally into the socket, depending on the socket type.

29 Slide 29 Replacing the PCIe Riser (X2270 / X2270 M2) 29 On the X2270 and X2270 M2 server, the PCIe riser card plugs into a motherboard connector. To remove the riser card, assuming there is no PCIe board installed, all you need to do is pull the riser card vertically out of the motherboard socket. 1 To install a replacement riser card plug the riser card into the motherboard socket.

30 Slide 30 Replacing the PCIe Riser (X4170 / X4170 M2) 30 There are 3 single slot riser cards on the X4170 and X4170 M2 servers so their replacement is different than the dual slot riser cards on the X4270 and X4275 servers and their M2 models. To replace a PCIe riser card, assuming the server blade is already on an anti-static mat with its cover off, 1 you need to loosen the two captive screws of the back panel crossbar 2 then lift it out of the chassis. 3 Now, disconnect any internal cables to the PCIe board, if present, disengage the PCIe card from the riser and lift it out of the chassis. 4 Now, loosen the riser card s holding screw, disengage the riser card and lift it of the chassis. 5 The installation of a replacement riser card follows the reverse of this procedure making sure the riser card is properly secured by tightening the holding screw and returning the PCIe card to the riser, if one was present.

31 Slide 31 Replacing the PCIe Riser (X427x / X427x M2) 31 The riser cards on the X4270 and X4275 server and the M2 models are dual slot riser cards. Before removing the PCIe riser card, the server needs to be powered off and on an anti-static mat with its cover removed. 1 Once inside the chassis make sure that all internal cables to the riser card or its PCIe boards are disconnected. Now remove the 2 captive Phillips screws on the ends of the PCI crossbar and lift the crossbar out of the chassis. 2 Remove the captive Phillips screws that holds the riser card to the motherboard. You can now remove the riser card from the motherboard. 3 To install a replacement riser card, install the riser card on the motherboard connector and secure it with Phillips screws. 4 Now install the crossbar and secure it with two screws on the ends of the crossbar.

32 Slide 32 Replacing a PCIe Card (X2270 / X2270 M2) 32 On the X2270 and X2270 M2 server there is only one PCIe slot available. To remove a PCIe board from this slot, disconnect any cables that care connected to the PCIe board, unlatch the PCIe card and slide the card from PCIe slot in the back panel of the server chassis. 1 Then disengage the PCIe card from the riser card connector and lift it out of the chassis. 2 Reverse the procedure to install a replacement PCIe card, making sure you re-engage the latch.

33 Slide 33 Replacing a PCIe Card (X4170 / X4170 M2) 33 The PCIe cards on the X4170 and X4170 M2 servers can be installed into three possible PCIe slots off of 3 separate riser cards. 1 First, unplug all cables connected to the PCIe card. Then loosen the Phillips screws to the riser card and lift the riser card along with the PCIe card off the chassis. 2 Now disengage the PCIe card from the riser card. To install a replacement PCIe board, just reverse the procedure. 3 If no PCIe board replacement will be performed make sure to install a filler panel in the open chassis slot.

34 Slide 34 Replacing a PCIe Card (X4270 / X4270 M2) The PCIe cards on the X4270 and X4275 servers and the M2 models can be installed into six possible PCIe slots off of three dual slot riser cards. 1 First, unplug all cables connected to the PCIe card, then remove the two Phillips screws to the PCI crossbar and lift the crossbar out of the chassis. 2 Now, loosen the captive screw on the riser card and lift the riser card and PCIe card out of the chassis. 3 Finally, disengage the PCIe card from the riser card. To install a replacement PCIe board, just reverse the procedure. 4 If no PCIe board replacement will be performed make sure to install a filler panel in the open chassis slot.

35 Slide 35 Replacing the Front I/O Board (X2270 / X2270 M2) 35 The I/O board on the X2270 and X2270 M2 servers can be removed from its chassis by first removing the three screws securing the I/O board to the HDD cage then lifting the I/O board out of the chassis and disconnecting any cables attached to the I/O board. 1 To install the replacement I/O board, connect the internal cables, slide the I/O board forward until the front connectors are flush with their chassis cutout then align the I/O board screw holes with their corresponding standoffs. Finally, fasten the three screws to secure the I/O board.

36 Slide 36 Replacing the Disk Backplane (X2270 / X2270 M2) NOTE: Record which drive slot each disk drive came out of. 36 The disk backplane on the X2270 and X2270 M2 servers can be replaced once its disks are removed. 1 Note, make sure to record which drive slot each disk drive came out of. 2 First, remove all power and data cables from the disk backplane, 3 then remove the 8 Phillips screws that fasten the disk backplane to the motherboard. You can now lift the disk backplane out of the chassis. 4 Reverse this process to install a replacement disk backplane.

37 Slide 37 Replacing the Disk Backplane (X4170 / X4170 M2) NOTE: Record which drive slot each disk drive came out of. Remove: disks DVD storage drive cage 37 The disk backplane on the X4170 and X4170 M2 servers can be replaced once its disks, DVD and storage drive cage along with the disk backplane are removed from the chassis. 1 Note, make sure to record which drive slot each disk drive came out of. 2 To separate the disk backplane from the storage drive cage, remove the two Phillips screws holding the backplane to the cage then slide the disk backplane off the storage drive cage retention hooks. 3 To install a replacement disk backplane, reverse the procedure and reinstall the assembly in the chassis then return the disks and DVD.

38 Slide 38 Replacing the Disk Backplane (X427x / X427x M2) NOTE: Record which drive slot each disk drive came out of. 38 To access the disk backplane on the X4270 and X4275 servers as well as the M2 models, you need to remove the fan module, the SAS expander board and the disk drives. 1 Note, make sure to record which disk slots each drive came out of. 2 In addition, the disk backplane two power cables, signal cable and light pipe cable need to be disconnected. 3 To remove the disk backplane from the storage drive cage, remove the two Phillips screw holding the backplane to the cage then use the backplane handles to remove the disk backplane from the storage drive cage. 4 To install a replacement disk backplane, reverse the procedure and reinstall cables, SAS expander board and fan modules.

39 Slide 39 Replacing a Flash Module (X2270 / X2270 M2) NOTE: The X2270 does not support FMODs but does support flash cards. CAUTION: Do not attempt a replacement procedure while the flash module green power LED, on the motherboard located next to the slot, is lit. 39 The X2270 and X2270 M2 servers have a pair of flash modules referred to as FMODs. 1 Note, the X2270 does not support FMODs but does support flash cards. 2 Caution, do not attempt a replacement procedure while the flash module slot LED, located on the motherboard next to the slot, is lit. After the server is powered down it should take approximately 10 seconds for the flash module slot LED to turn off. 3 To remove a flash module push down its two handles which will disengage the module from its socket then lift it vertically out of its socket. 4 To install a replacement flash module, seat the device in the socket and push down on it until its handles lock it in.

40 Slide 40 Replacing a Flash Module (X4x7x / X4x7x M2) CAUTION: Do not attempt a replacement procedure while the flash module slot LED, on the motherboard located next to the slot, is lit. 40 The X4170, X4270 and X4275 servers and its M2 models have a pair of flash modules referred to as FMODs. To locate a failed FMOD press the fault remind button, then determine if the FMOD s amber fault LED, pointed out by the white arrow, is lit. 1 Caution, do not attempt a replacement procedure while the flash module slot LED, located on the motherboard next to the slot, is lit. After a server is powered down it should take approximately 10 seconds for the flash module slot LED to turn off. 2 To remove a flash module push down its two handles which will disengage the module from its socket then lift it vertically out of its socket. 3 To install a replacement flash module, seat the device in the socket and push down on it until its handles lock it in.

41 Slide 41 Replacing an ESM and Riser (X4170 / X4170 M2) 41 The ESM and its riser, on the X4170 and X4170 M2 servers, are located 1 between the DIMM slots and the PCIe slots next to the power supplies. To remove the ESM and riser, 2 remove the three Phillips screws that secure the assembly to the motherboard then lift the assembly out of the chassis. To remove the ESM, 3 disconnect the ESM power cable, lift off the ESM plastic case cover, 4 then lift the ESM out of its plastic casing. To install the ESM and its riser, 5 just reverse the procedure making sure you 6 secure it using the three Phillips screws.

42 Slide 42 Replacing an ESM Riser (X427x / X427x M2) 42 The ESM and its riser, on the X4270 and X4275 servers and the M2 models, are located 1 between the DIMM slots and the PCIe slots next to the power supplies. To remove the ESM and riser, 2 remove the three Phillips screws that secure the assembly to the motherboard then lift the assembly out of the chassis. To remove the ESM, 3 disconnect the ESM power cable, lift off the ESM plastic case cover, 4 then lift the ESM out of its plastic casing. To install the ESM and its riser, 5 just reverse the procedure making sure you secure the ESM and its riser using the three Phillips screws.

43 Slide 43 Replacing the Light Pipe Assembly (X4170 / X4170 M2) Remove: Install: storage disk backplane drive cage disk storage backplane drive cage 43 To remove the light pipe assembly from the X4170 and X4170 M2 servers you first need to remove the storage drive cage and disk backplane. 1 Once these components have been removed, remove the two Phillips screws that secures the light pipe assembly to the storage drive cage. 2 Then slide the light pipe assembly out of the storage drive cage. 3 To install a replacement light pipe assembly, secure it in the storage drive cage using the two Phillips screws. 4 Then install the disk backplane and storage drive cage back in the chassis.

44 Slide 44 Replacing the Light Pipe Assembly (X427x / X427x M2) 44 The light pipe assembly on the X4270 and X4275 servers and the M2 models does not require the removal of any components prior to its removal. 1 First, remove the Phillips screw that secures the light pipe assembly to the server front panel. 2 Then disconnect light pipe assembly cable from the disk backplane and pull the cable gently through the side wall of the chassis. Now remove the light pipe assembly from the server front panel. To install a replacement light pipe assembly, reverse this procedure making sure 3 you carefully pull the assembly s cable through the chassis side wall 4 and secure the assembly using the Phillips screw.

45 Slide 45 Replacing the Paddle Board (X4170 / X4170 M2) Remove: motherboard disk backplane Install: disk backplane motherboard 45 The paddle board, on the X4170 and X4170 M2 servers, is an infrastructure board that is powered once AC power is applied to the server. 1 To access the paddle board, remove the motherboard, the power distribution board and the fan module next to the paddle board. Start the paddle board removal 2 by disconnecting its fan power and signal cables. Remove the two screws holding the board and its support bracket to the chassis mid wall. 3 Slide the assembly towards the rear of the chassis to disengage the paddle board edge connector from the disk backplane and lift it out of the chassis. To separate the paddle board from the support bracket, remove its two supporting screws. 4 To install a replacement paddle board, connect the paddle board to its support bracket using the two Phillips screws, install the assembly into the chassis, connect the fan power and signal cables and secure the assembly using the other two Phillips screws. 5 You can now reinstall the disk backplane and motherboard.

46 Slide 46 Replacing the Paddle Board (X427x / X427x M2) Remove: PDB and fan modules 1. Disk backplane power cable 2. Fan board power cable 3. Fan board ribbon cable 4. Disk backplane ribbon cable Install: PDB and fan modules 46 The paddle board, on the X4270 and X4275 servers and the M2 models, is an infrastructure board that is powered once AC power is applied to the server. 1 To access the paddle board remove the power distribution board and the two fan modules next to the paddle board. Start the paddle board removal 2 by labeling and disconnecting all of the cables from the paddle board. 3 Remove the two Phillips screws holding the paddle board and bracket to the chassis mid wall, slide the paddle board and bracket towards the rear of the chassis and lift it out of the chassis. Separate the paddle board from its support bracket by removing the two holding screws. 4 To install a replacement paddle board, install the paddle board to its support bracket using the two Phillips screws, install the assembly into the chassis, connect the disk and fan cables and secure the assembly using the other two Phillips screws. 5 You can now reinstall the power distribution board and fan modules.

47 Slide 47 Replacing Internal Cables (X2270 / X2270 M2) blower power cables (3) SATA cable harness front I/O cable motherboard power cable blower main power cable SATA backplane power cable 47 On the X2270 and X2270 M2 servers there are six cable types. 1 The blower power cables need to be routed from one of three blowers through the mid wall cut out to the motherboard power connector. 2 The front I/O cable follow a similar route from the front I/O board through the mid wall to the motherboard. 3 The SATA cable harness routs the SATA signals from the disk backplane connectors through the mid wall cut outs to the designated motherboard connectors. 4 The motherboard power cable and blower main power cable are connected directly from the power supply to the motherboard. 5 The SATA backplane power cable is routed from the power supply through the mid wall cutout to the disk backplane.

48 Slide 48 Configuring SAS/SATA Cables (X4x7x / X4x7x M2) HDD cables in SATA configuration PCIe HBA 4 5 HDD cables in SAS configuration NOTE: Review either the corresponding Service Manual for the individual steps of the replacement procedure. 48 The SAS interfaces for the X4170, X4270 and X4275 servers and M2 models are supported through a PCIe SAS HBA 1 while SATA interfaces are supported through the ICH SouthBridge chip. So for the SAS connections, the HDDs are connected 2 to PCIe HBA ports, while the SATA connections to the HDDs are connected 3 to SATA port 4 and 5 on the motherboard. 4 Note, review the corresponding Service Manual for the individual steps of the replacement procedure.

49 Slide 49 Replacing the DVD (X4x70 / X4x70 M2) 49 A DVD drive is supported on the X4170 and X4270 servers and the M2 models. To access the DVD drive, 1 first remove the disk or filler in the bottom right slot. 2 Now, pull out the release tab below the DVD drive as you disengage the DVD drive from the backplane connector and slide the drive out. 3 To install a replacement DVD drive, slide it into the slot until it engages the disk backplane connector. Keep sliding the DVD drive in until the release tab locks. Now return either the disk drive or filler into the bottom right slot.

50 Slide 50 Replacing the Storage Drive Cage (X4170 / X4170 M2) Remove: disk drives (record their slot positions) DVD 50 To access the storage drive cage, you first have to remove all the disk drives and the DVD from the cage recording the slot positions of each disk drive. 1 Now you can start the removal of the storage drive cage 2 by removing the four Phillips screws that holds the cage and backplane assembly in the chassis and disconnecting all the disk backplane cables. 3 Slide the cage assembly forward to disengage the it from the paddle board then lift it out of the chassis. Refer to the disk backplane procedure to separate the backplane from the storage drive cage. To install a replacement storage drive cage, 4 reverse the procedure by sliding in the cage assembly, engaging it to the paddle board, 5 reconnecting all the disk backplane cables 6 and securing it using the four Phillips screws. Now return all the disk drives and the DVD.

51 Slide 51 Replacing the PDB (X4170 / X4170 M2) 51 On the X4170 and X4170 M2 servers, to access the Power Distribution Board you need to first remove the power supplies and the motherboard. To remove the PDB, 1 disconnect the top cover chassis intrusion switch cable from the PDB 2 then remove the Phillips screw that holds the PDB to the chassis. 3 Now disengage the PDB edge connector from the paddle board by pulling the assembly to the right using the bus bar and lift it out of the chassis. 4 To install a replacement PDB, reverse the procedure placing the PDB in the chassis, 5 sliding it to engage its edge connector with the paddle board 6 then reconnecting the intrusion cable and securing the PDB with the Phillips screw.

52 Slide 52 Replacing the PDB (X427x / X427x M2) 52 On the X4270 and X4275 servers and the M2 models, to remove the power distribution board from the chassis you need to 1 disconnect the power supply ribbon cable, 2 the top cover interlock and the motherboard ribbon cable from the PDB. Now you can 3 remove the 4 Phillip screws securing the PDB to the chassis and the 5 Phillip screws securing the PDB to the bus bar. 4 The PDB is then disengaged from the paddle board by sliding the PDB away from the chassis wall and lifted out of the chassis. To install a replacement PDB, reverse the procedure 5 placing the PDB in the chassis, sliding it to engage its edge connector with the paddle board, 6 securing the PDB in the chassis 7 and reconnecting all the cables.

53 Slide 53 Replacing the Motherboard (X2270 / X2270 M2) Remove: air duct SP module PCIe cards PCIe riser assembly FMODs, DIMMs CPU and heat sink assemblies All cables attached to the motherboard 53 To access the motherboard on the X2270 and X2270 M2 servers, you need to remove the air duct, the SP module, any PCIe cards, the PCIe riser assembly, the FMODs, the DIMMs and the CPU and heat sink assemblies. In addition, you need to disconnect all cables attached to the motherboard and keep them clear of the motherboard. 1 Now to remove the motherboard 2 remove the eight screws that secure the motherboard to the chassis then lift the motherboard straight up and out of the chassis. 3 To install a replacement motherboard, place it in the chassis with eight screw holes aligned then secure the motherboard in the chassis. Now replace all the components you removed to access the original motherboard.

54 Slide 54 Replacing the Motherboard (X4170 / X4170 M2) Remove: SAS cables DIMMs CPUs FMODs PCIe riser and card ESM 54 To access the motherboard on the X4170 and X4170 M2 servers, you need to disconnect the SAS cables from the SAS PCIe card or the on-board SATA connectors on the motherboard. Then remove the DIMMs, the CPUs, the FMODs, PCIe risers, the PCIe cards, and the ESM. To remove the motherboard, 1 disconnect the power distribution board ribbon cable, 2 remove the four screws that secure the motherboard to the bus bar, loosen the captive screw on the front of the motherboard that secures the motherboard to the chassis. 3 Then using the finger loop just below the four screws that secure the motherboard to the bus bar, carefully slide the motherboard to the rear of the chassis and lift it out of the chassis. 4 Also, remove the screw that secures the finger loop/air plenum to the motherboard and set the it aside. 5 To install a replacement motherboard, reverse the procedure starting with the finger loop/air plenum. 6 Slide in the motherboard into the chassis 7 and secure it to the bus bar using the 4 screws 8 then reinstall the PDB ribbon cable.

55 Slide 55 Replacing the Motherboard (X427x / X427x M2) Remove: Air Baffle SAS cables DIMMs CPUs FMODs PCIe riser and card ESM 55 To access the motherboard on the X4270 and X4275 servers and the M2 models, you need to remove the plastic air baffle, disconnect the SAS storage drive cables from the SAS PCIe card or the on-board SATA connectors located on the motherboard, the DIMMs, the CPUs, the FMODs, the PCIe risers and attached PCIe cards, and the ESM. To install a replacement motherboard, 1 disconnect the power distribution board ribbon cable, 2 remove the four screws that secure the motherboard to the bus bar and loosen the captive screw on the front of the motherboard that secures the motherboard to the chassis. Now using the finger loop just below the four screws that secures the motherboard to the bus bar, carefully slide the motherboard to the rear of the chassis and lift it out of the chassis. 3 To install a replacement motherboard, reverse the procedure by sliding the motherboard into the chassis and secure it to the bus bar using the 4 screws 4 then reinstall the PDB ribbon cable.

56 Slide 56 PROPERTIES On passing, 'Finish' button: Goes to Next Slide On failing, 'Finish' button: Goes to Next Slide Allow user to leave quiz: At any time User may view slides after quiz: At any time User may attempt quiz: Unlimited times

57 Slide 57 Summary Prepare the server for installation Prepare the server for component replacement Name the key steps of replacing the server or its components 57 Now that you completed this module, you should be able to 1 prepare the server and its components for replacement and name the key steps in the replacement of its components. This completes this module.

58 Slide 58 Oracle is the Information Company 58

59 Slide 59 Oracle 59

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

HP ProLiant DL165 G7 Server

HP ProLiant DL165 G7 Server HP ProLiant DL165 G7 Server Installation Instructions Part Number 601464-003 Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 LFF HDD Item Description 1 Thumbscrews

More information

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:

More information

Installing imac Intel 27" EMC 2390 Dual HDD or

Installing imac Intel 27 EMC 2390 Dual HDD or Installing imac Intel 27" EMC 2390 Dual HDD or SSD Drive Installing a secondary HDD or SSD in the mid 2010 27" imac EMC 2390. Written By: Brett Hartt ifixit CC BY-NC-SA www.ifixit.com Page 1 of 23 INTRODUCTION

More information

Dell Inspiron XPS and Inspiron 9100 Service Manual

Dell Inspiron XPS and Inspiron 9100 Service Manual Dell Inspiron XPS and Inspiron 9100 Service Manual Dell Inspiron XPS and Inspiron 9100 Service Manual Before You Begin Memory Module, Mini PCI Card, and Devices System Components Subwoofer Bluetooth Card

More information

Chassis (FRU) Replacement Guide

Chassis (FRU) Replacement Guide SIEM9750 Release 1.0 Chassis (FRU) Replacement Guide Issue: 02 Date: 2011-11-07 Page 1 of 26 This document is intended for Symantec support personnel, IBM, or other authorized Symantec Service Partners.

More information

Removing and Replacing Parts

Removing and Replacing Parts Removing and Replacing Parts Preparing to Work Inside the Computer Recommended Tools Screw Identification System Components Hard Drive Fixed Optical Drive Media Bay Devices Memory Modules Mini PCI Card

More information

Wiwynn SV Maintenance User Manual

Wiwynn SV Maintenance User Manual Wiwynn SV7220-2 Maintenance User Manual Version 1.1 Published Sept. 2014 Copyright 2014 Wiwynn. All rights reserved Copyright Copyright 2014 by Wiwynn Corporation. All rights reserved. No part of this

More information

E4233. English. P-Series. ASUS PC (Desktop Barebone) Installation manual. Download the latest manual from the ASUS website:

E4233. English. P-Series. ASUS PC (Desktop Barebone) Installation manual. Download the latest manual from the ASUS website: E P-Series ASUS PC (Desktop Barebone) Installation manual P P Download the latest manual from the ASUS website: www.asus.com Front/Rear panel features P Front (Close) P Front (Close) Front (Open) Rear

More information

Contivity Extranet Switch Installing Hardware Options Guide

Contivity Extranet Switch Installing Hardware Options Guide Contivity Extranet Switch Installing Hardware Options Guide Part Number 302283-B Rev.00 Installing LAN and WAN Option Cards...2 System Board Layouts... 2 Removing the 4500 Option Card Tray... 5 4500 Option

More information

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com. Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com. Please check out our ebay auctions for more great deals on Factory Service Manuals: servicemanuals4u Dell Latitude

More information

Wiwynn SV320 Maintenance User Manual

Wiwynn SV320 Maintenance User Manual Wiwynn SV30 Maintenance User Manual Version. Published Apr. 03 Copyright 0 Wiwynn. All rights reserved Content System Upgrades...5 Opening the Server...5 Removing the Top Cover... 5 Installing the Top

More information

S E R V I C E N O T E

S E R V I C E N O T E IINFORMATIION ONLY S E R V I C E N O T E Supersedes: MSO8104A-05 MSO8104A Digitizing Oscilloscope Serial Numbers: MY00000000-MY46001900 SG00000000-SG46001900 The original scopes motherboard is no longer

More information

Oracle <Insert Picture Here>

Oracle <Insert Picture Here> Slide 1 Oracle Slide 2 WZT-5160 SPARC T3 Based Servers Architecture and Features Welcome to the SPARC T3 Based Servers Architecture and Features module. This

More information

Reflowing Xbox 360 Motherboard

Reflowing Xbox 360 Motherboard Reflowing Xbox 360 Motherboard Reflow the solder on your Xbox 360's motherboard. Written By: Andrew Bookholt ifixit CC BY-NC-SA www.ifixit.com Page 1 of 31 INTRODUCTION Use this guide to reflow the solder

More information

Dell Latitude C800 Service Manual

Dell Latitude C800 Service Manual Dell Latitude C800 Service Manual Dell Latitude C800 Service Manual Before You Begin Preparing to Work Inside the Computer Recommended Tools Screw Identification Removing and Replacing Parts System Components

More information

Field Service Guide Supplement for the NS 7000/030

Field Service Guide Supplement for the NS 7000/030 AUSPEX Field Service Guide Supplement for the NS 7000/030 Copyright 1998, Auspex Systems, Inc. All rights reserved. Part number 850550. Important Notice The installation or replacement procedures in this

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not

More information

HP ProLiant SL160z G6 Server

HP ProLiant SL160z G6 Server HP ProLiant SL160z G6 Server Installation Instructions Part Number 571291-004 Item Description 7 UID LED/SW 8 PCI Slot 9 Health LED 10 Power Button Rear Panel Components Figure 2 Rear panel components

More information

To connect the AC adapter:

To connect the AC adapter: Replacing the AC Adapter Replacing the AC Adapter 3 Plug the power cord into a wall outlet. The power indicator turns on. To connect the AC adapter: Connect the power cord to the AC adapter. Power indicator

More information

Replacing the SATA PCI Controller Card

Replacing the SATA PCI Controller Card Replacing the internal controller PCI card may be performed by a single administrator; no tools are necessary. Caution There are static-sensitive electronics inside the unit. Before you handle any parts,

More information

Installation Guide. Copyright 2005 MSI Computer Corp.

Installation Guide. Copyright 2005 MSI Computer Corp. Installation Guide Copyright 2005 MSI Computer Corp. Overview: 1013 is shipped out as a barebone. Some of the components are equipped while some are not. This installation guide provides you with the information

More information

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems. DNS-2670 User Manual Version Dec. 2015 DataON Storage, storage division of Area Data Systems. Contents 1 Introduction... 1 1.1 System Overview... 3 1.1.1 System Top View...3 1.1.2 Front View...4 1.1.3

More information

imac Intel 27" EMC 2429 SSD Dual Drive

imac Intel 27 EMC 2429 SSD Dual Drive imac Intel 27" EMC 2429 SSD Dual Drive Installation Install the dual hard drive kit in an imac Intel 27" EMC 2429. Written By: Dozuki System 2017 guides.crucial.com Page 1 of 22 INTRODUCTION This guide

More information

Written By: Walter Galan

Written By: Walter Galan PlayStation 3 Motherboard Replacement Replace your PS3's motherboard. Written By: Walter Galan ifixit CC BY-NC-SA www.ifixit.com Page 1 of 24 INTRODUCTION Use this guide to replace a blown motherboard.

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

PC9/P9 CPU Card Replacement

PC9/P9 CPU Card Replacement Introduction These instructions explain how to replace the CPU card in the PC9 Industrial PC or the P9 PowerStation. They include steps for disassembling the unit, removing the old CPU card, installing

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

Servicing a Blade Server

Servicing a Blade Server This chapter contains the following sections: Replacing a Drive, page 1 Removing a Blade Server Cover, page 4 Air Baffles, page 5 Internal Components, page 6 Diagnostics Button and LEDs, page 7 Installing

More information

Dell Inspiron 660 Owner s Manual

Dell Inspiron 660 Owner s Manual Dell Inspiron 660 Owner s Manual Computer model: Inspiron 660 Regulatory model: D11M Regulatory type: D11M002 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

Dell Latitude V710/V740 Service Manual

Dell Latitude V710/V740 Service Manual Dell Latitude V710/V740 Service Manual Dell Latitude V710/V740 Service Manual Before You Begin Preparing to Work Inside the Computer Recommended Tools Computer Orientation Screw Identification System Components

More information

Installing System Board Options

Installing System Board Options CHAPTER 8 Installing System Board Options This section describes how to install the following options: Expansion cards Memory modules Microprocessor This section also includes instructions for replacing

More information

Written By: John Sutton

Written By: John Sutton Replacing the fan on your HP g7-2275 dx. Written By: John Sutton ifixit CC BY-NC-SA www.ifixit.com Page 1 of 20 INTRODUCTION Laptop cooking your lap? This guide will walk you through replacing your fan.

More information

Replacing/Upgrading Mac Pro Processors (Early 2008)

Replacing/Upgrading Mac Pro Processors (Early 2008) Replacing/Upgrading Mac Pro Processors (Early 2008) The steps in this procedure illustrate how to remove the lower processor (CPU B). The instructions are the same for removing the upper processor (CPU

More information

Replacement Instructions. Backplane PCA for the HP Router 650

Replacement Instructions. Backplane PCA for the HP Router 650 Replacement Instructions Backplane PCA for the HP Router 650 Copyright Hewlett-Packard Company 1994. All rights reserved. Publication Number 5962-8369 Edition 1, August 1994 Printed in USA This guide provides

More information

Gateway Profile 4 service guide

Gateway Profile 4 service guide Gateway Profile 4 service guide Customizing Troubleshooting Contents Replacing Components in Your Gateway Profile 4.................. 1 About this guide.....................................................

More information

Installing and Upgrading Memory and Virtual Private Network Modules

Installing and Upgrading Memory and Virtual Private Network Modules APPENDIX C Installing and Upgrading Memory and Virtual Private Network Modules This chapter tells how to install or upgrade memory and how to install a Virtual Private Network (VPN) module in your Cisco

More information

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Assembly Introduction The Replacement Kit provides a replacement backlight for the PanelMate Power Pro 1785 Series,

More information

ALIENWARE AURORA SERVICE MANUAL 01/

ALIENWARE AURORA SERVICE MANUAL 01/ ALIENWARE AURORA SERVICE MANUAL 01/ 01 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential

More information

120Ra-1 Pentium III Processor Installation Insert

120Ra-1 Pentium III Processor Installation Insert 120Ra-1 Pentium III Processor Installation Insert PN: 455-01614-000 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide Quick Start Guide Upgrade kit contents The table below shows the contents of the V5420 Host Card Upgrade Kit (components are not shown to scale). Part Function Pieces V5420 Host Card 1 Host card bracket

More information

How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit

How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit Instructional Video Series How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit Skill Level: Challenging Time to Complete: Approximately 45 Minutes Required

More information

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com. Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com. Please check out our ebay auctions for more great deals on Factory Service Manuals: servicemanuals4u Dell Inspiron

More information

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID 17 March 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc. All rights reserved. Overview Xserve RAID

More information

Maintaining the Avaya S8800 Server for Avaya Aura SIP Enablement Services

Maintaining the Avaya S8800 Server for Avaya Aura SIP Enablement Services Maintaining the Avaya S8800 Server for Avaya Aura SIP Enablement Services 03-603448 Issue 1 November 2009 2011 Avaya Inc. All Rights Reserved. is 1-800-242-2121 in the United States. For additional support

More information

After completing this chapter, you will meet these objectives:

After completing this chapter, you will meet these objectives: 3.0 Introduction Assembling computers is a large part of a technician's job. As a technician, you will need to work in a logical, methodical manner when working with computer components. As with any learned

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing

More information

Written By: Walter Galan

Written By: Walter Galan imac Intel 21.5" EMC 2428 CPU Replacement Replace the CPU in your imac Intel 21.5" EMC 2428. Written By: Walter Galan ifixit CC BY-NC-SA www.ifixit.com Page 1 of 33 INTRODUCTION Use this guide to upgrade

More information

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

Chapter 4 Replacement Procedures

Chapter 4 Replacement Procedures Chapter 4 Replacement Procedures 4 4-ii Satellite P30 Series Maintenance Manual Chapter 4 Contents 4.1 General... 4-1 4.2 Battery... 4-7 4.3 PC Card... 4-8 4.4 HDD... 4-10 4.5 Optical Drive Module... 4-12

More information

The Fone Works. Written By: The Foneworks. This a teardown guide of the PlayStation 3. PlayStation 3 Motherboard Teardown

The Fone Works. Written By: The Foneworks. This a teardown guide of the PlayStation 3. PlayStation 3 Motherboard Teardown The Fone Works PlayStation 3 Motherboard Teardown This a teardown guide of the PlayStation 3. Written By: The Foneworks 2017 thefoneworks.dozuki.com Page 1 of 23 INTRODUCTION This is a teardown guide based

More information

Installing and Removing SDRAM and DRAM

Installing and Removing SDRAM and DRAM CHAPTER 4 This chapter explains how to remove and replace the main memory modules on the network processing engine or network services engine. For the location of the memory module you are replacing, find

More information

Hardware Replacement Guide

Hardware Replacement Guide Hardware Replacement Guide Types 6491, 8013, 8702, 8706 Types 8716, 8970, 8972, 8976 Types 8980, 8982, 8986, 8992 Types 8994, 9266, 9276, 9278 Types 9282, 9286, 9288, 9374 Types 9378, 9380, 9384, 9628

More information

Dell SC5020 and SC5020F Storage System Owner s Manual

Dell SC5020 and SC5020F Storage System Owner s Manual Dell SC5020 and SC5020F Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

Xbox 360 Motherboard Replacement

Xbox 360 Motherboard Replacement Xbox 360 Motherboard Replacement Motherboard replacement. Redigido por: Walter Galan ifixit CC BY-NC-SA pt.ifixit.com Página 1 de 29 INTRODUÇÃO Use this guide to completely strip down your motherboard.

More information

Adding or Replacing a PCI Card

Adding or Replacing a PCI Card Caution There are static-sensitive electronics inside the unit. Before you handle any parts, make sure you are working at a static-controlled workstation and that you are properly grounded. Three PCI cards

More information

System Storage DS3950 Quick Start Guide

System Storage DS3950 Quick Start Guide System Storage DS3950 Quick Start Guide This Quick Start Guide describes the basic procedure for installing, cabling, and configuring the IBM System Storage DS3950 storage subsystem (Machine Types 1814-94H

More information

4.1 General. 4 Replacement Procedures

4.1 General. 4 Replacement Procedures 4.1 General This chapter explains how to disassemble the computer and replace Field Replaceable Units (FRUs). It may not be necessary to remove all the FRUs in order to replace one. The chart below is

More information

Dell Inspiron N5110 Service Manual

Dell Inspiron N5110 Service Manual Dell Inspiron N5110 Service Manual Regulatory model: P17F Regulatory type: P17F001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

SCv3000 and SCv3020 Storage System. Owner s Manual

SCv3000 and SCv3020 Storage System. Owner s Manual SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not

More information

Installing the NVR Connectivity and 2nd CPU Kits 1

Installing the NVR Connectivity and 2nd CPU Kits 1 Installing the NVR Connectivity and 2 nd CPU Kits Avigilon provides two optional kits for network video recorders (NVR): NVR Connectivity Kit (HD-NVR3-PRMEXP-DAS-CONNECT-KIT) provides all the components

More information

Managing Individual Components

Managing Individual Components CHAPTER 3 This chapter describes how to install the Field Replaceable Units (FRUs) in the Cisco SFS 7008P system. About the Field Replaceable Units The following Field Replaceable Units (FRUs) are a part

More information

Maintaining the Cisco Catalyst 5500 Multiswitch Router

Maintaining the Cisco Catalyst 5500 Multiswitch Router 7 CHAPTER Maintaining the Cisco Catalyst 5500 Multiswitch Router Revised: December 3, 2009, This chapter contains recommended hardware maintenance procedures for the Cisco Catalyst 5500 Multiswitch Routers

More information

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide Intel NUC Kit DN2820FYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety

More information

HP Pavilion dv7-6c90us Cooling fan Replacement

HP Pavilion dv7-6c90us Cooling fan Replacement HP Pavilion dv7-6c90us Cooling fan Replacement This guide will walk you through the process of replacing the cooling fan in an HP Pavilion dv7 laptop. Written By: Angelina Clayton ifixit CC BY-NC-SA www.ifixit.com

More information

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com. Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com. Please check out our ebay auctions for more great deals on Factory Service Manuals: servicemanuals4u Dell Inspiron

More information

Installation & Replacement

Installation & Replacement Installation & Replacement Follow the individual procedures to perform the notebook s installation and replacement of various major components. Z70N Series Notebook is a fusion of flexibility, style and

More information

Figure 4-29 Removing the CPU compartment cover

Figure 4-29 Removing the CPU compartment cover 4 Replacement Procedures 4.9 CPU 4 4.9 CPU Removing the CPU To remove the CPU, follow the steps below. 1. Turn the computer upside down and remove two M2.5 4 security screws securing the CPU compartment

More information

HP ProLiant MicroServer

HP ProLiant MicroServer HP ProLiant MicroServer Installation Sheet Part Number 615715-004 Panel door components Item Component 1 16 screws for HDD installation 2 4 screws for ODD installation 3 Screw driver Rear panel components

More information

SCSI Cable Installation Instructions

SCSI Cable Installation Instructions Identifying the SCSI Cable Parts SCSI Cable Installation Instructions for HP ProLiant DL100 Series Generation 2 Servers Item Description 1 Connector end 2 240 mm location 3 Terminator end Read instructions

More information

imac Intel 21.5" EMC 2389 Stand Replacement

imac Intel 21.5 EMC 2389 Stand Replacement imac Intel 21.5" EMC 2389 Stand Replacement Replace a broken or cosmetically unappealing stand on the imac 2389 21.5 Written By: Aaron Cooke ifixit CC BY-NC-SA www.ifixit.com Page 1 of 30 INTRODUCTION

More information

ThinkCentre. Hardware Removal and Replacement Guide Types 8143, 8144, 8146 Types 8422, 8423, 8427

ThinkCentre. Hardware Removal and Replacement Guide Types 8143, 8144, 8146 Types 8422, 8423, 8427 ThinkCentre Hardware Remoal and Replacement Guide Types 8143, 8144, 8146 Types 8422, 8423, 8427 ThinkCentre Hardware Remoal and Replacement Guide Types 8143, 8144, 8146 Types 8422, 8423, 8427 First Edition

More information

MacBook Pro 13" Unibody Mid 2010 SSD Dual Drive Installation

MacBook Pro 13 Unibody Mid 2010 SSD Dual Drive Installation MacBook Pro 13" Unibody Mid 2010 SSD Dual Drive Installation Use this guide to install a second SSD in place of the optical drive. Written By: Dozuki System 2017 guides.crucial.com Page 1 of 13 INTRODUCTION

More information

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May 2004 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc.

More information

Toshiba Satellite A210 Motherboard

Toshiba Satellite A210 Motherboard Toshiba Satellite A210 Motherboard Replacement In this guide you will learn how to properly remove the Motherboard. Written By: Devin ifixit CC BY-NC-SA www.ifixit.com Page 1 of 12 INTRODUCTION Before

More information

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211 Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211 Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215,

More information

imac Intel 20" EMC 2105 and 2118 SSD

imac Intel 20 EMC 2105 and 2118 SSD imac Intel 20" EMC 2105 and 2118 SSD Installation Replace the hard drive in your imac Intel 20" EMC 2105 and 2118. Written By: Dozuki System 2017 guides.crucial.com Page 1 of 15 INTRODUCTION Upgrade your

More information

Megatouch FORCE Monitor Chassis Board Replacement

Megatouch FORCE Monitor Chassis Board Replacement Megatouch FORCE Monitor Chassis Board Replacement Visit the Merit Industries, Inc. Web site http://www.meritind.com merit industries, inc. PM0337-01 Rev C Table of Contents FORCE Classic Monitor Chassis

More information

Dell Latitude E6500 Teardown

Dell Latitude E6500 Teardown Dell Latitude E6500 Teardown Disassembling the Dell Latitude E6500. Step by Step. I disassemble it down to the base assembly. Written By: Luis Gomez ifixit CC BY-NC-SA www.ifixit.com Page 1 of 16 INTRODUCTION

More information

Removing and Replacing FRUs from the Cisco ASR 1001-X Router

Removing and Replacing FRUs from the Cisco ASR 1001-X Router Removing and Replacing FRUs from the Cisco ASR 1001-X Router This chapter describes procedures for removing and replacing field-replaceable units (FRUs) from Cisco ASR 1001-X Routers. This chapter contains

More information

CRESCENDO /7200 G3. Quick Start Guide for Crescendo /7200. Processor Upgrade Card for Power Macintosh 7200/8200 Computers

CRESCENDO /7200 G3. Quick Start Guide for Crescendo /7200. Processor Upgrade Card for Power Macintosh 7200/8200 Computers CRESCENDO /7200 G3 Processor Upgrade Card for Power Macintosh 7200/8200 Computers Quick Start Guide for Crescendo /7200 System Compatibility At this printing, processor upgrade cards are compatible with

More information

TravelMate 6493 Series Disassembly Instruction

TravelMate 6493 Series Disassembly Instruction TravelMate 6493 Series Disassembly Instruction please refer to http://csd.acer.com.tw PRINTED IN TAIWAN Chapter 3 Machine Disassembly and Replacement This chapter contains step-by-step procedures on how

More information

Series 3700 Screw Terminal Assemblies Installation Instructions

Series 3700 Screw Terminal Assemblies Installation Instructions Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Series 3700 Screw Terminal Assemblies Installation Instructions Introduction This document contains handling

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing

More information

Inspiron 22. Service Manual Series. Regulatory Model: W17B Regulatory Type: W17B001

Inspiron 22. Service Manual Series. Regulatory Model: W17B Regulatory Type: W17B001 Inspiron 22 3000 Series Service Manual Regulatory Model: W17B Regulatory Type: W17B001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Dell XPS M1730 Service Manual

Dell XPS M1730 Service Manual Dell XPS M1730 Service Manual Model PP06XA www.dell.com support.dell.com Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE:

More information

Written By: Brett Hartt

Written By: Brett Hartt Yellow Light of Death Repair Fix consoles plagued with the infamous "Yellow Light of Death". Written By: Brett Hartt ifixit CC BY-NC-SA www.ifixit.com Page 1 of 32 INTRODUCTION [video: http://www.youtube.com/watch?v=umg-6rbanly]

More information

Removal and Installation8

Removal and Installation8 8 Screw Types 8-4 Top Cover Assembly 8-5 Left Hand Cover 8-6 Right Hand Cover 8-10 Front Panel Assembly 8-14 Left Rear Cover 8-15 Right Rear Cover 8-16 Extension Cover (60" Model only) 8-17 Media Lever

More information

Written By: Walter Galan

Written By: Walter Galan imac Intel 17" Power Supply Replacement Written By: Walter Galan ifixit CC BY-NC-SA www.ifixit.com Page 1 of 18 INTRODUCTION Power hungry? Keep those electrons flowing by replacing your power supply. TOOLS:

More information

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE Intel NUC Kit DC53427HYE User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety

More information

Samsung Galaxy Tab Speaker

Samsung Galaxy Tab Speaker Samsung Galaxy Tab 2 10.1 Speaker Replacement This guide will show you how to replace a broken speaker in your tablet. Written By: Matthew Weeman ifixit CC BY-NC-SA www.ifixit.com Page 1 of 11 INTRODUCTION

More information

System Storage EXP3000 Rack Installation Instructions

System Storage EXP3000 Rack Installation Instructions System Storage EXP3000 Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When you install the IBM System Storage EXP3000 in a

More information

Installing MacBook Pro 15" Unibody Mid 2009 Dual Hard Drive

Installing MacBook Pro 15 Unibody Mid 2009 Dual Hard Drive Installing MacBook Pro 15" Unibody Mid 2009 Dual Hard Drive Use this guide to install a second hard drive in place of the optical drive. Written By: Brittany McCrigler ifixit CC BY-NC-SA www.ifixit.com

More information

Le Disassembly. Required Tools Disassembly Instructions Reassembly Instructions

Le Disassembly. Required Tools Disassembly Instructions Reassembly Instructions Le Div@ Disassembly Required Tools Disassembly Instructions Reassembly Instructions Required Tools All Le Div@ maintenance procedures can be performed using the following tools: Tweezers Small flat-head

More information

imac Intel 20" EMC 2105 and 2118 Hard Drive

imac Intel 20 EMC 2105 and 2118 Hard Drive imac Intel 20" EMC 2105 and 2118 Hard Drive Replacement Replace the hard drive in your imac Intel 20" EMC 2105 and 2118. Written By: Walter Galan ifixit CC BY-NC-SA www.ifixit.com Page 1 of 16 INTRODUCTION

More information

Dell Latitude C800 SERVICE MANUAL. support.dell.com

Dell Latitude C800 SERVICE MANUAL.  support.dell.com Dell Latitude C800 SERVICE MANUAL www.dell.com support.dell.com Dell Latitude C800 SERVICE MANUAL www.dell.com support.dell.com Notes, Notices, and Cautions NOTE: A NOTE indicates important information

More information

2 To display the Administration Home page, click the Administration link. (You may need to provide the Administrator password.)

2 To display the Administration Home page, click the Administration link. (You may need to provide the Administrator password.) The Disk Drive Snap Server 4100 To install the new disk drive properly, follow the procedure carefully. Failure to follow instructions puts your data at risk. These preparatory steps assist you in completing

More information

Codonics Virtua Virtua-2 Optical Drive Replacement

Codonics Virtua Virtua-2 Optical Drive Replacement Codonics Virtua Virtua-2 Optical Drive Replacement Technical Brief Overview This document describes the procedure for replacing an optical drive on a Codonics Virtua Medical Disc Publisher, Virtua-2 model.

More information