Uniflo 1200 GVEC Accessories Uniwire to RS232 converter

Size: px
Start display at page:

Download "Uniflo 1200 GVEC Accessories Uniwire to RS232 converter"

Transcription

1 Uniflo 1200 GVEC Accessories Uniwire to converter Product number : Manual M/06180XX/51 Rev Please look at our homepage that you have the newest version of the document.

2 CONTENT 1.0 Functionality Mounting Installation type 1, Uniwire to converter for EX installation: Installation type 2, to Uniwire converter installation: Installation type 3, to optical isolated port at communication controller installation: Installation type 4, to optical isolated port at communication controller EX installation: Ex description General ATEX and intrinsic safety (Installation type 1 and 4 only): Installation, inspection and maintenance in hazardous environment Technical data Dimensions Common specifications Markings... 7 Page 2 of 8

3 1.0 Functionality The Uniwire to converter is used between data signal and either Uniwire or opto isolated port on communication interface for Uniflo 1100 or Uniflo Reference to Uniflo 1100 Installation Manual for general information. Reference to Uniflo 1200 Installation Manual for general information. Definitions Technicians are qualified persons educated or trained to mount, operate, and also troubleshoot technically correct and in accordance with safety regulations. Limitations This manual only applies to the following Product numbers: Uniwire to converter and only for mounting in non-hazardous area. Repair of the unit and replacement of components must be done by Flonidan only. 2.0 Mounting Only technicians who are familiar with the technical terms, warnings, and instructions in the manual and who are able to follow these should connect the module. Should there be any doubt as to the correct handling of the module, please contact your local distributor or, alternatively, Flonidan DC A/S - Islandsvej 29 - DK-8700 Horsens Tel Fax mail@flonidan.dk Mounting and connection of the module should comply with national legislation for mounting of electric materials, i.a. wire cross-section, protective fuse, and location. Descriptions of input / output and supply connections will follow in this paper. When mounting the option board please also observe the guidelines in the paper "ESD correct handling". 2.1 Installation type 1, Uniwire to converter for EX installation: To be connected between an port and Uniwire (going into hazardous area) with a serial data communication isolator (type MTL5051) in between. See chapter 3 for additional EX limitations. safe area (Blue terminals) hazard area DB9 2 RX Uniwire B 10 6 RX 6 1 Uniwire B 3 TX Uniwire A 12 Isolated 5 TX 4 3 Uniwire A 5 GND 11 Barrier 2 12V 5 Uniwire to 1 GND 2 +V 24VDC 14 MTL5051 converter -V 13 Setting switches at MTL a = off. 1b = on. 2a = off. 2b = on. Setting jumper inside. Jumper must be short circuit. The MTL5051 need additional power supply 24VDC. Page 3 of 8

4 2.2 Installation type 2, to Uniwire converter installation: As above but with no serial data communication isolator. DB9 2 RX 6 1 Uniwire B 3 TX 4 Uniwire to 3 Uniwire A 4 DTR # 5 5 GND # 2 converter Setting jumper inside. Jumper must be short circuit. 2.3 Installation type 3, to optical isolated port at communication controller installation: To connect a port to the optical isolated port at communication controller for Uniflo 1100 & DB9 2 RX T 3 TX R Uniwire to 4 DTR # 5 5 GND # 2 converter 2 3 C x-yyy Communicationcontroller terminals x-yyy is wildcard Setting jumper inside. Jumper must be open circuit. 2.4 Installation type 4, to optical isolated port at communication controller EX installation: To connect a port to the optical isolated port at a communication controller for Uniflo 1100 & 1200 (placed in hazardous area), with a serial data communication isolator (type MTL5051) and zener barrier in between. Only receiving data: safe area hazard area (Blue terminals) Zener barrier 2 RX 10 Isolated 6 RX 8 PEPPERL & 1 6 Uniwire to 1 1 T 5 GND R Barrier FUCHS 3 TX V C +V 24V 14 MTL GND 7 Z converter -V 0V 13 Setting switches at MTL a = off. 1b = off. 2a = off. 2b = on. Two way communication: safe area hazard area (Blue terminals) Zener barrier 2 RX 10 Isolated 6 RX 6 1 RX T Uniwire to 5 GND 11 5 TX 4 3 TX R Barrier 3 TX V 5 2 GND 7 FUCHS 2 3 C +V 24V 14 MTL GND 2 converter -V 0V 13 Z961 Setting switches at MTL a = off. 1b = on. 2a = off. 2b = on. PEPPERL & Zener barrier: The intrinsic safety does not depend on the earth connections on the Zener barrier. Therefore it s not needed to connect the earth terminals on the Zener barrier. See in chapter 3 for additional EX limitations. Page 4 of 8

5 Setting jumper inside. Jumper must be open circuit. The MTL5051 need additional power supply 24VDC. Notes: # Instead of supply from terminal 4 DTR it is possible to use external supply. Then connect: 0V at terminal 2 and +7-12VDC at terminal 5 on to Uniwire converter. Page 5 of 8

6 3.0 Ex description 3.1 General The Uniwire to converter cannot be placed in hazardous environment, but it can be connected to Uniflo 1200 in hazardous area via Uniwire or the communication controller. 3.2 ATEX and intrinsic safety (Installation type 1 and 4 only): The product is a simple apparatus Only to be connected in the intrinsic safe circuit between communication isolator MTL5051 manufactured by Measurement technology LTD and Flonidan intrinsic safe Uniwire circuit. The MTL5051 isolators don t need protective ground. Or by using MTL5051 and zener barrier PEPPERL & FUCHS Z961 to reduce EX data signals from MTL5051 to fit opto output at communication controller. Zener barrier: The intrinsic safety does not depend on the earth connections on the Zener barrier. Therefore it s not needed to connect the earth terminals on the Zener barrier. Keep the intrinsic safe terminals at MTL5010, converter and Uniwire terminals away from other not safe signals. A creepage distance of 50mm is adequate. Placement in safe area only! 3.3 Installation, inspection and maintenance in hazardous environment Repair of the unit and replacement of components must be done by Flonidan only. For Installation, inspection and maintenance it s recommended to follow the standards: EN Electrical apparatus for explosive gas atmospheres Part 14. Electrical installations in hazardous area (other than mines). EN Electrical apparatus for explosive gas atmospheres Part 17. Inspection and maintenance of electrical installations in hazardous area (other than mines). It s also recommended to follow the guidelines in DS-Håndbog 144. Page 6 of 8

7 4.0 Technical data 4.1 Dimensions 4.2 Common specifications Operating temperature: -30 C 60 C 4.3 Markings The Analogue Input board has the following markings Description Marking Explanation Example Product name Uniwire to converter Product number Flonidan stock no.: Terminal description Terminals: 1: Data in (Uniwire B) 2: COM 3: Data out (Uniwire A) 4: input 5: V+ power (5-12VDC) 6: output ATEX information ATEX and intrinsic safety: See chapter 3. This product is a simple apparatus. Refering to installation manual for safe use. Placement in safe area only! Flonidan logo CE marking WEEE marking Page 7 of 8

8 Revision history Rev. Init Comment TF Document created TF Two way communication added for Installation type 4 Flonidan DC A/S - Islandsvej 29 - DK-8700 Horsens Tel Fax mail@flonidan.dk Page 8 of 8

gavc 1200 EVCD Accessories GSM board Product number : 94042

gavc 1200 EVCD Accessories GSM board Product number : 94042 gavc 1200 EVCD Accessories GSM board Product number : 94042 Former item no: 0618650-000 Manual M/94042 Please look at our homepage www.gavilar.nl for the newest version of the document. CONTENT 1.0 Introduction...

More information

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5 EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications. EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier

More information

How to calculate an Intrinsically Safe loop approval.

How to calculate an Intrinsically Safe loop approval. MIE TALK - October 2016 How to calculate an Intrinsically Safe loop approval. EXPLOSIVE ATMOSPHERES Compile by: Gary Friend BSc PrEng, CEng MIET, Sales DirectorExtech Safety Systems (MTL, Beka Associates,

More information

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W Title INTRINSICALLY SAFE Ex ia PSU TYPE AC36W USER MANUAL Document Number 66-184-12 Issue 10 10 Update new logo and address 2017.10.18 CW CW PC 09 Added Um as 265V, Io up to 3.3A & IIB data 2017.08.21

More information

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

M E M O R A N D U M I.S.

M E M O R A N D U M I.S. Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,

More information

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU) Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU) Rev. 2 September 2012 Part No. 4417552 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax :

More information

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.1.S - 0 CMU 100 / 7.1.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.1.S - 0 User manual CMUMU11S

More information

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ NanoServ Thin System/Ultra-Thin System Setup Guide 1.0 What s included with the NanoServ The following items are included with the NanoServ : 1. NanoServ 2. AC Power Adaptor 3. CD-ROM with User s Manual

More information

Enclosure TS-530 User Manual

Enclosure TS-530 User Manual Enclosure TS-530 User Manual 16525 East Laser Drive Fountain Hills, AZ 85268 TEL 480.837.5200 FAX 480.837.5300 info@embeddedx86.com http://www.embeddedx86.com/ Technologic Systems, Inc. COPYRIGHT 1998-200

More information

Operating Instructions

Operating Instructions Operating Instructions KBDi-DS102W-xxx R. STAHL HMI Systems GmbH Adolf-Grimme-Allee 8 D 50829 Köln Operating Instructions Version: 01.00.05 Issue date: 19.09.2018 Disclaimer Disclaimer Publisher and copyright

More information

DC Power Considerations for Intrinsically Safe Applications

DC Power Considerations for Intrinsically Safe Applications Chapter 3 Intrinsically Safe Fieldbus Applications This chapter provides information about fieldbus applications that provide Intrinsically Safe (IS) power to fieldbus devices located in hazardous areas.

More information

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-022 2017A-0330 4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System SYSTEM INSTALLATION INFORMATION Description The 4 Channel

More information

R507 I.S. Interface Module User Manual

R507 I.S. Interface Module User Manual R507 I.S. Interface Module R507 I.S. Interface Module User Manual Contact Mercury HMI Ltd George House Derwent Road Malton North Yorkshire YO17 6YB Page 2 of 14 Tel: +44 (0) 1653 697200 Fax: +44 (0) 8700

More information

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001 PROCESS AUTOMATION MANUAL Z-System Zener Barriers ISO9001 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and

More information

Safety instructions Overvoltage protection B81-35

Safety instructions Overvoltage protection B81-35 Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application

More information

USB COMMUNICATIONS INTERFACE LOOP LINK Contents. Side 1. Page 15. Page 29. Seite 43

USB COMMUNICATIONS INTERFACE LOOP LINK Contents. Side 1. Page 15. Page 29. Seite 43 USB COMMUNICATIONS INTERFACE LOOP LINK 5909 DK Side 1 Contents 5 9 0 9 L o o p L i n k U S B C o m m u n i c a t i o n s I n t e r f a c e N o. 5 9 0 9 V 1 0 1 - I N ( 1 0 0 7 ) F r o m s e r. n o. 0 4

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

Operating Manual Extension for Vane Anemometer MiniAir6/60/64-Ex

Operating Manual Extension for Vane Anemometer MiniAir6/60/64-Ex Operating Manual Extension for Vane Anemometer MiniAir6/60/64-Ex Article no.: 93.xxxx Type: g.641.6xs-yyy Micro g.642.6xs-yyy Mini g.648.6xs-yyy Macro II (1/2) G [Ex ia] IIC Issue date: June 2008 For Sensor

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor with analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection

More information

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas technical datasheet technical datasheet MTL0 Displays Loop-powered indicators for hazardous areas Loop powered -0mA Field and panel mounting Environmental protection to IP7 Easy to configure Number of

More information

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor.   Operating Instructions: EN. EN/2017-04-03 Design and specifications subject to change without notice English page 1 8 Field of application CombiTemp TFRx is a temperature sensor, based on RTD technology, which is designed and produced

More information

Temperature Converters

Temperature Converters TURCK Interface Technology Temperature measurement is a very common application, even in hazardous areas. The IM34 temperature converting device provides advanced diagnostics, versatility and convenience

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Emergency power supply NV2.1-12iaE

Emergency power supply NV2.1-12iaE Ordering Data Designation Type Item no. 372 100 04 AX Supply of consumers even in case of failure or shutdown of the input / charging current circuit NiCd as energy store Intrinsically safe input voltage

More information

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus Safety Instructions PMC71, PMP71, PMP75 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex ia IIC T6 Ga/Gb IECEx KEM06.0011 0 XA00696P-D Safety instructions for electrical apparatus for explosion-hazardous

More information

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505 Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation IV-30 Operating Manual for Pulse Distributor Cassette with potential separation Edition-/Rev.-Date: 09/08/2006 Document-/Rev.-No.: TR - EAK - BA - GB - 0093-02 Software version: - File name: TR-EAK-BA-GB-0093-02.DOC

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069 D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according

More information

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Universal Safety IO System board for Honeywell Universal Process IO For 6-channel cards USIO and UPIO For 6 modules Recommended modules: HiC8R (DI), HiC85R

More information

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.6.S - 0 CMU 100 / 7.6.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.6.S - 0 User

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

Manual Mouse Module CHALLENGER Mi-PS2 / Mi-PS2-B

Manual Mouse Module CHALLENGER Mi-PS2 / Mi-PS2-B Manual Mouse Module CHALLENGER Mi-PS2 / Mi-PS2-B GECMA.COMPONENTS GMBH WWW.GECMA.COM TEL. +49 2237 6996-0 FAX -99 MANUAL MI_PS2_B REV 1.3 EN.DOC 31.01.07 A. J. 1 List of contents List of contents... 2

More information

Installation Instruction. HART Add-On Module

Installation Instruction. HART Add-On Module - Translation Typs 17-A1Z0-0005, B7-A2Z0-0033 and G7-A0Z0-0007 Version for: Non hazardous areas ATEX/IECEx Zone 1 and Zone 2 UL Class I Division 1 and Division 2 Document No.: B1-A2Z0-7N0001 / 400570 Revision

More information

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous

More information

Features and Benefits. Certifications

Features and Benefits. Certifications NPort IA5000 Series 1 and 2-port serial device servers for industrial automation Features and Benefits Socket modes: TCP server, TCP client, UDP Patented ADDC (Automatic Data Direction Control) for 2-wire

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas.

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas. Industrial Opto-Isolated RS-232 to RS-422/485 Converter Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas. Rugged IP30-rated metal case for panel mounting. Quick Start Guide Customer

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology 485DRCI RS-232 RS-485 2-Wrie RS-422/485 4-Wire RS-232 CON. RS-422/485 CON. Data Rate Isolation Surge Protection Industrial Bus Source Input Voltage Power Consumption Connector p/n 7207r3 485DRCI-4108ds

More information

GT- IRDM-9603 Product description Rev. 2 17/06/2014

GT- IRDM-9603 Product description Rev. 2 17/06/2014 GT- IRDM-9603 Product description Rev. 2 17/06/2014 1 1. Overview The GT- IRDM- 9603 is a complete Satellite Terminal solution for Satellite applications. Based on IRIDIUM 9603 module. 2. Hardware Interface

More information

HMCom. Modem GSM/GPRS. Edition 0.4

HMCom. Modem GSM/GPRS. Edition 0.4 Modem GSM/GPRS Edition 0.4 User manual Date 25/02/2016 Edition 0 Revision 4 Date 2/25/2016 Index 1. Introduction... 2 1.1 Description 2 1.2 Safety Information 2 1.3 Block Diagram/external connections 3

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

Split2.8 RDM. 2 input DMX/RDM Splitter. User guide Split2.8 RDM 2 input DMX/RDM Splitter User guide Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be installed

More information

UIM Series Flowmeter Field Wiring Guide

UIM Series Flowmeter Field Wiring Guide UIM Series Flowmeter Field Wiring Guide DATE 1 OF 13 TI2_UIM_GEN21_FIELD_WIRING_GUIDE.DOCX Table of contents 1 Contents of this document... 4 1.1 Conventions... 4 1.2 Related documents... 4 Abbreviations...

More information

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L.

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L. CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / 1.5.9 CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / 7.5.9 CMU 100 / 7.M.9 CMU 100 / 7.L.9-0 0 0 0 0 0 CMU 100 - RS485 to Ethernet Converter Content

More information

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S D109S INSTRUCTION MANUAL SIL Relay Output Module with Line and diagnostics DINRail Model D109S D109 SIL Relay Output Module with Line and diagnostics ISM0096 SIL Applications For Safety Related System

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL Operating Instructions 12/2010 MN04802006Z-EN MICRO PANEL 2 Device description 2.3 Device versions 2.3 Device versions Fig. 1 MICRO PANELs are available in the following versions: Basic device Display

More information

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Safety instructions. IECEx TUN Ex ia IIC T6 Gb Safety instructions ÜSB62-36G.C_* and ÜSB62-30W.C_* IECEx TUN 07.0002 Ex [ia Ga] IIC T6 Gb Ex ia IIC T6 Gb 0044 39878 Content 1 Area of applicability 3 2 General 3 3 Electrical data 3 3.1 Application conditions

More information

KBMG MULTI-SPEED BOARD

KBMG MULTI-SPEED BOARD TM INSTALLATION AND OPERATION MANUAL KBMG MULTI-SPEED BOARD KB Part No. 8833 Multi-Speed Board for KBMG Series Regenerative Drive Pending! See Safety Warning on Page 1 The information contained in this

More information

Interface and Supply module. IPC 3x0i / PSC 3x0i

Interface and Supply module. IPC 3x0i / PSC 3x0i Interface and Supply module IPC 3x0i / PSC 3x0i Installation Guide Version 10 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.: +49 2241 9199801 53925 Kall Fax.: +49 2241 9199871 Germany www.ibs-batchcontrol.com

More information

Digital Proximity System Installation Manual

Digital Proximity System Installation Manual Digital Proximity System Installation Manual 1180 The DPS (Digital Proximity System) family consists of two devices, the MX2033 and MX2034. The MX2033 is a conventional 3-wire driver while the MX2034 is

More information

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detecting angular positions of 0 to 360 P1-Ri-DSU35 positioning element included in delivery

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

INTRINSICALLY SAFE ACOUSTIC EMISSION TRANSDUCERS

INTRINSICALLY SAFE ACOUSTIC EMISSION TRANSDUCERS Abstract INTRINSICALLY SAFE ACOUSTIC EMISSION TRANSDUCERS RAN ZHOU and STAN HALE Score Atlanta Inc., 975 Cobb Place Blvd. Suite 202, Kennesaw GA, 30144 Intrinsic safety (IS) is a signaling technique that

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology 485DRCI Industrial RS-232 to RS-422/485 Converter p/n 7207r5 485DRCI-2212ds page 1/5 Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

Black Box Tech Support: FREE! Live. 24/7.

Black Box Tech Support: FREE! Live. 24/7. Black Box Tech Support: FREE! Live. 24/7. Tech support the way it should be. Great tech support is just 30 seconds away at 724-746-5500 or blackbox.com. About Black Box Black Box Network Services is your

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor BI5-EM18-Y1X-H1141

Inductive sensor BI5-EM18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

IPC/USB485D-101E. user documentation. Document Ordercode: DOC/IPC_USB485D-E. Revision Date Author Modification S. Mutter First Release

IPC/USB485D-101E. user documentation. Document Ordercode: DOC/IPC_USB485D-E. Revision Date Author Modification S. Mutter First Release user documentation IPC/USB485D-101E Document Ordercode: DOC/IPC_USB485D-E Revision Date Author Modification 1.0 02.08.2017 S. Mutter First Release ipc_usb485e.docx Page 1 of 15 Contents 1 Introduction

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

This installation guide provides instructions for installing the SPARTAN HP Highbay/ Floodlight series of explosion protected floodlights.

This installation guide provides instructions for installing the SPARTAN HP Highbay/ Floodlight series of explosion protected floodlights. SPX/SPZ SPARTAN HIGH POWER LUMINAIRE RANGE Installation Guide Zone 1 Variant - CML17ATEX1148 & IEC Ex CML17.0074 Zone 2 Variant - CML17ATEX4149 & IEC Ex CML17.0074 This installation guide provides instructions

More information

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215 Operating Instructions Power Supply & Isolation Relay for Switches Model: RL-5900 manual_rl-5900_0215 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

Language of the manual

Language of the manual USER S MANUAL INSTALLATION AND Language of the manual Product English Single-phase switching power supply: 24V @ 1.5A Description Contents: 1.0 Disclaimer 2.0 Description and General features Page 2 2

More information

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A Installation Guide Standalone/Spare V6 SDI QBox QBox-V6 Standalone/Spare V6 SDI QBox Part No. A9009-0004 EN www.autocue.com Copyright 2017 All rights reserved. Original Instructions: English All rights

More information

Moxa TCC-100 Series Hardware Installation Guide

Moxa TCC-100 Series Hardware Installation Guide Moxa TCC-100 Series Hardware Installation Guide Twelfth Edition, January 2015 www.moxa.com/product 2015 Moxa Inc. All rights reserved. P/N: 1802001000319 Moxa TCC-100 Series Hardware Installation Guide

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

RS-232 to RS-422/485 Converter with 3KV Isolation Protection

RS-232 to RS-422/485 Converter with 3KV Isolation Protection RS-232 to RS-422/485 Converter with 3KV Isolation Protection (ID-SC0E11-S1) User s Manual 04-0779A - 1 - Introduction The serial converter converts RS 232 signals to RS 422 or RS 485 and extends the communication

More information

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1 USER S MANUAL VER.1 C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1 MARCH 2018 User s Manual Page i USER'S MANUAL TABLE OF CONTENTS Contents Page # 1.0 OVERVIEW... iii 2.0 FEATURES... iii 3.0 SPECIFICATIONS...

More information

Installation Guide MODELS 522 / 526. Pressure Transducers TOLL FREE FAX Web Site.

Installation Guide MODELS 522 / 526. Pressure Transducers TOLL FREE FAX   Web Site. Installation Guide MODELS 522 / 526 Pressure Transducers 1-800-257-3872 TOLL FREE 1-978-264-0292 FAX www.setra.com Web Site 560550-0087 Rev A Setra offers a complete line of products for these industries:

More information

SoundwebTM. Installation Guide

SoundwebTM. Installation Guide 105 SoundwebTM Soundweb TM 9000 Installation Guide Soundweb TM Regulatory Information An example of this equipment has been tested and found to comply with the following European and international Standards

More information

NPort 5100 Series Quick Installation Guide

NPort 5100 Series Quick Installation Guide NPort 5100 Series Quick Installation Guide Edition 4.0, November 2015 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div. Termination Board HiCTB08-SCT-C-SC-RA Features Assembly For 8 modules V DC supply Supported signal types: DI/DO/AI/TI/AO Hazardous area: screw terminals, blue Safe area: screw terminals, black Function

More information

SMARTLINE RM76 Supplementary instructions

SMARTLINE RM76 Supplementary instructions SMARTLINE RM76 Supplementary instructions 2-wire / Guided Radar (TDR) Level Meter Supplementary Instructions for ATEX applications CONTENTS SMARTLINE RM76 1 General safety information 5 1.1 Scope of the

More information

EOS-6000 Series Optical A/B Switch User Manual DC Version

EOS-6000 Series Optical A/B Switch User Manual DC Version EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2

More information

DTM Distributed Transmitter Monitor

DTM Distributed Transmitter Monitor Distributed Transmitter Monitor 96 Communication Module The 96 functions as an RS232 to RS485 convertor and / or enables (32) modules to be networked together via Modbus. Combined with the -CFG configuration

More information