1 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1 Table Of Contents Section Description Page # 3. Multispense 2000 W/Touchscreen Controller Module Description Front Panel Controls & Indicators Rear Panel Detail Operation Control Touchscreen PLC Interface Operating Modes Operating Parameters Status Information Installation Options PLC Interface With Independent Channel Ready PLC Interface With Independent Channel Trigger Touchscreen Maintenance Assembly/Disassembly Procedures Problem Guide Optically Isolated Serial Interface Specifications Model Number Illustrated Parts Breakdown April, 2013 IVEK Corp. P03L008K

2 Page 3-2 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE 3. MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE 3.1 DESCRIPTION The Multispense 2000 W/Touchscreen Controller Module, hereafter referred to as the Controller Module, contains all the control, monitoring, and interface components for the dispensing operations. The operator controls and interface connections are located on the front and rear panels Front Panel Controls & Indicators (Figure 3.1) The front panel of the Controller Module is largely made up of the individual front panels of the Multispense Master Plug-In PCB (printed circuit board), hereafter referred to as the Master Plug-In and the Multispense 2000 Channel Plug-In PCB, hereafter referred to as the Channel Plug-In. Based on the customer s preference, the main power switch, main power fuse and power cord may be on the front or rear panel Touchscreen (Figure 3.1 Item 1) The touchscreen is the operator interface for controlling the system. Multiple screens are provided for setting and monitoring system parameters. With a touch of the screen, parameters can be viewed and changed to meet specific requirements Master Plug-In (Figure 3.1 Item 3) Serial Interface data Indicators (2) - A red LED (Light Emitting Diode) indicates data being received by the Master Card, a green LED indicates data being transmitted by the Master Card Channel Plug-In (Figure 3.1 Item 4) Enabled Indicator (5) - (green) illuminates while this channel is enabled for operation. Disabled Indicator (6) - (red) illuminates while this channel is NOT enabled for operation. Enable Switch (7) - This switch allows this channel to be enabled or disabled without using the serial interface. The normal position will be the middle (maintained) position where the channel can be enabled or disabled via the serial interface. Moving the switch to the top (SELECT momentary) position will toggle the state between ENABLE and DISABLE. The bottom (LOCKOUT maintained) position will disable the channel and will not allow the serial interface to enable the channel. The lockout position is used to insure a particular Motor/Base Module will not be operated. If the channel is attempted to be enabled, a warning message will indicate the lockout condition Refer to Figure 3.20 for Touchscreen dimensions Figure 3.1 Multispense 2000 Controller Module Front Panel P03L008K IVEK Corp. 10 April, 2013

3 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-3 Active Indicator (8) - (green) illuminates while pump is operating. Idle Indicator (9) - (red) illuminates while pump is not operating. Load Indicator (10) (yellow) - This indicator illuminates while the pump requires a load cycle or while the pump is loading. Fault Indicator (11) - (red) illuminates when there is any system or pump fault. Actuator Module Connector (12) - A Channel Plug-In for an Actuator Module will have a 14 pin female connector. A Channel Plug-In for an Actuator Module with the encoder option will have a 16 pin male connector. (Refer to the Title section of this manual to see if the encoder option was purchased.) Rear Panel Detail (Figure 3.2) The rear panel contains the PLC connector and either a power entry module or a power cord with a separate system fuse. The PLC connector provides connections to the customer's PLC. The power entry module and power cord provide an entry point for power coming into the Controller Module. The power cord and separate system fuse are used for large multiple channel systems Power Entry Module (Figure 3.2 Item 1) The power entry module contains a receptacle for a standard IEC power cord, a voltage selector switch and main fuse holder. CAUTION Before plugging in the system, insure the line voltage setting appearing in the window agrees with the available line voltage. Damage to the equipment could result if the two voltages do not match. Refer to the Title Page section of this manual to determine the power connection and fuse specifications for this Controller Module. The design of the power entry module requires the line cord be disconnected before either the voltage select switch is changed or a line fuse is removed. Perform the following steps if it is necessary to change the setting of the line voltage select switch. 1. Disconnect the line cord at the power entry module and open its cover. 2. Remove the selection cam from the unit and replace it oriented so the desired voltage will appear in the window when the cover is closed. CAUTION Rotating the voltage select cam while it is in the module may damage the module. 3. With the voltage select cam in the proper position, close the cover and replace the line cord. If the cover does not completely close, open the cover and slightly reposition the voltage select cam IEC Connector (If Power Entry Module Not Supplied) The IEC Connector is provided with medium size multiple channel systems. A separate system fuse is located near the power cord. The system is factory configured for the line voltage specified in the Title Page section of this manual. Refer to the Title Page section of this manual to determine the power connection and fuse specifications for this Controller Module Power Cord (If Power Entry Module or IEC Connector Not Supplied) 1 2 The power cord is provided with large multiple channel systems. A separate system fuse is located near the power cord. The system is factory configured for the line voltage specified in the Title Page section of this manual. Refer to the Title Page section of this manual to determine the power connection and fuse specifications for this Controller Module. Figure 3.2 Multispense 2000 Controller Module Rear Panel 10 April, 2013 IVEK Corp. P03L008K

4 Page 3-4 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE PLC Connector (Figure 3.2 Item 2) Introduction The PLC connector (Amp Series One CPC 9 pin) is used for making the electrical connection to the PLC Interface Device. A PLC Connector Kit (Part Number ) is supplied with the unit. 3.2 OPERATION The Controller Module provides the controls for producing liquid flow via a positive displacement pumping mechanism. The systems utilize solid-state electronics, stepping motor drives, and precision machined ceramic pump heads. These components combine to provide exceptional accuracy and precision, high reliability, and low maintenance. IVEK units have custom designed stepping motors and pumps sized to the specific dispensing application to provide the proper torque and speed Control All operational parameters on the Controller Module are programmed through the touchscreen using an RS-232 interface to the Controller Module. Total electronic control allows for effortless, exacting calibration and full accountability of cumulative volumes dispensed. Software contained in the Controller Module's Master Plug-In allows configuration and operation on a system-wide or individual channel basis. NOTE Parameters are stored in the Touchscreen Memory. Changing a Channel Plug-In in the Controller Module will not change parameter settings. All volume and rate commands for the Controller Module use microliters or microliters per second Touchscreen The touchscreen provides an operator interface to all operating parameters in the Controller Module. New values can be entered and current values displayed for all the functions of the system. The touchscreen contains eleven different operator interface screens with each providing information to the operator. Start and Stop buttons appear on two screens for starting and stopping the system. Configurations A configuration is a collection of the operating parameters required to operate the system. The operating parameters include volume, rate, direction and drawback. For each configuration, the parameters are stored in the configuration database. NOTE All channels use the same value for a given parameter. Buttons A button initiates a command being sent to the IVEK Multispense 2000 Controller Module. The "Start" and "Stop" area in the Main screen (Figure 3.10) are examples of buttons. Boxes A box looks identical to a button, but provides information only. Pressing a box will have no effect on the system. The "CHANNEL" and "DESCRIPTION" area in the Fault Screen (Figure 3.15) are examples of boxes. Screens There are eleven screens used to setup, operate and exit the system as shown in Figure 3.3. Each screen contains information relating to operating the system. The screens and a brief description are as follows: Power-Up Screen The channels are referenced from this screen after power-up. Main Screen Volume, Rate and Dwell settings are viewed here. The system can be operated from this screen. Volume and Rate Screen Volume and Rate settings are viewed and changed here. The system can be operated from this screen. Configuration Screen Configurations are changed and stored with this screen. Any parameters changed outside the configuration will not be saved as a configuration. Params A Screen Displays Totalizer, Permission, Prime Duration and Ready Out information. Params B Screen Displays software versions, Pump Size and Controller serial number. P03L008K IVEK Corp. 10 April, 2013

5 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-5 POWER-UP SCREEN Reference Channels MAIN SCREEN Start Stop Ready Indicator View Parameters FAULT SCREEN View Faults Clear Faults Reference Channels Connection Status VOLUME & RATE SCREEN Start Volume Stop Disp/Meter Rate Direction Priming Rate Mode Ready Indicator CONFIGS SCREEN View/Edit Configurations DRAWBACK SCREEN Volume Dwell Rate Valving Speed CONFIGURATION HELP SCREEN View Pump Options PARAMS A SCREEN Totalizer Functions Change Permissions Prime Duration Ready Out Config CLEAR TOTALIZER SCREEN Clear Totalizers PARAMS B SCREEN Software Version Change Permissions Serial Number Pump Size EXIT SCREEN Exit Software Figure 3.3 Screen Information 10 April, 2013 IVEK Corp. P03L008K

6 Page 3-6 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Drawback Screen Drawback and Valving Speed settings are viewed and changed here. Configuration Help Screen Pump reference information is displayed here. Fault Screen Faults are displayed and cleared. Clear Totalizer Screen Clears all totalizer values. Exit Screen Exit the software. Figure 3.3 shows the screens and provides an overview of the function of each screen. Lines and arrows show accessibility for each screen. Another display, called the Keypad, only appears on the top of screens. The Keypad is used for changing the selected parameter and is shown in Figure Permission Levels There are three levels of permission; Operator, Manual and Supervisor. Each level allows access to selected items on the touchscreen. The permission level can be changed by using the "CHANGE PERMISSION" button in the Params A or Params B screen. Click on the button to display the Keypad then type in the password for the required level and press the "ENTER" key. The last values entered into the touchscreen before it was turned off will appear after the system has booted. The first screen displayed will be the Power-Up screen (Figure 3.7). This screen is displayed each time power is turned on. The "REFERENCE ALL CHANNELS" button must be pressed if the system is going to be operated. If the system is not going to be operated, press the "GO TO MAIN SCREEN" button. NOTE If the "REFERENCE ALL CHANNELS" button is not pressed, the system will not trigger and no fault messages will be displayed. The Next screen will be the Main screen containing the last parameter settings. Usually, the last parameter setting is either Dispense or Meter mode so it is a good idea to first go to the Configuration screen or enter the setting manually in the Volume & Rate and Drawback screens. If the touchscreen can not communicate with the Multispense 2000 Controller Module, a fault will occur. The fault can be cleared in the Fault screen. (section ) The communications flag shown in Figure 3.6 may also be displayed on the Touchscreen. The highest level is Supervisor. This level allows access to all items on all screens. The Manual level allows access to all items on all screens except changing values in the Configuration screen and access to the "EXIT" button on the Params B screen. The Operator level does not allow changing system parameters. Configurations can be selected and loaded, but not changed. If a button is not available because of the permission level, a security flag will be present over the button. Figure 3.5 shows the permission flag Getting Started Figure 3.5 Permission Flag The touchscreen will "Boot" when the power to the Controller Module is turned on. If the program is accidently exited, the Controller Module must be turned off and then back on. The "Boot" sequence will be visible on the Touchscreen and takes approximately one minute. Figure 3.6 Communications Flag Configuration Screen (Figure 3.8) The Configuration screen displays the parameter settings for each of the twenty five configurations. The system arrives with a few configurations preset and the remaining configurations set with default parameters. The current access level determines which buttons are currently available as shown in Figure 3.8. The configurations are the recommended method of changing operating parameters. Once a configuration has been created or changed it is available to use each time the system is used. Parameters not saved in configurations will be lost once the system is turned off. The twenty five configurations are named Configuration 1 through Configuration 25. The current configuration number is displayed in the Main screen. Each configuration can be programmed to perform a specific job function. All configuration parameters are numerical values and must be entered in the keypad as numbers. To use a preset configuration: P03L008K IVEK Corp. 10 April, 2013

7 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-7 Displays the value being entered. Displays minimum and maximum settings. Numerical Keypad. "Enter" loads the value into the selected parameter. "BS" deletes the last digit entered. Moves the keypad left and right on the screen. Deletes any entered value in the display and removes the keypad screen. Figure 3.4 Keypad Display 1. Use the "CONFIG ->" and "<- CONFIG" buttons to move to the desired configuration. 2. Press the "USE CONFIG" button to load the parameters into the Controller Module. To change a configuration; 1. Use the "CONFIG ->" and "<- CONFIG" buttons to move to the desired configuration. 2. Use the "PREV ITEM" and "NEXT ITEM" buttons to select the parameter. 3. Press the "EDIT ITEM" button. 4. The keypad appears with the minimum and maximum settings displayed. 5. Type the new parameter number. NOTE If a number smaller than the minimum is entered, a message will appear stating the minimum number which can be entered. If a number larger than the maximum is entered, a message will appear stating the maximum number which can be entered. 6. When all parameters are entered, press "SAVE CHANGES" or "IGNORE CHANGES". 7. To start using the new configuration press the "USE CONFIG" button. This will load the parameters into the Controller Module. An * appears in front of edited items until the changes are saved or ignored. When changing configurations, remember volumes are in "steps" (not microliters) and flow rates are in "steps per second" (not microliters per second). The chart on the Configuration Help screen can be used to assist with unit conversions. The correct value for "pump size" must be entered for the Pump Module being used. NOTE If an item has been edited and not saved and the "HELP" button is pressed, the edit will be lost. Always press the "SAVE CHANGES" button before pressing the "HELP" button Configuration Help Screen (Figure 3.9) The Configuration Help screen provides a quick reference for configuration setting information. This screen only provides information pertaining to the Configuration settings. The Configuration screen is accessible from this screen Main Screen (Figure 3.10) The Main screen displays the parameter settings for the configuration selected in the Configuration screen. The Main screen is normally used to operate the system. The Fault, Configuration and Vol & Rate screens are accessible from this screen. All the buttons on this screen are accessible by all permission levels. NOTE If a configuration has been selected and the parameters changed in the Volume & Rate or Drawback screens the Main screen will display the changed parameters. 10 April, 2013 IVEK Corp. P03L008K

8 Page 3-8 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE The Power-Up screen references all channels at power-up (See below for a description of each section) References all channels. (Must be pressed prior to operating the system.) Switches to the Main screen. Figure 3.7 Power-Up Screen The Configuration Help screen provides a quick reference for Configuration settings Switches to the Configuration screen. Figure 3.9 Configuration Help Screen P03L008K IVEK Corp. 10 April, 2013

9 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-9 The Configuration screens allow generating, changing and using preset parameters (See below for a description of each section) Operator Manual Supervisor Moves the cursor to the parameter above. Moves the cursor to the parameter below. Switches to the Help screen. Displays the keypad screen for making changes to the highlighted parameter. Switches to the Main screen. Lists the parameter settings for each configuration. (1-25) A * in left column indicates edited parameter. All parameters are not visible, use "NEXT ITEM" to view end of list. Switches to the next configuration. Switches to the previous configuration. Loads the selected configuration for use. Saves any changes made to the current configuration. Cancels any changes made to the current configuration. Figure 3.8 Configuration Screen 10 April, 2013 IVEK Corp. P03L008K

10 Page 3-10 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE The Main screen controls the system and displays the operating parameters (See below for a description of each section) Displays the current Volume setting in microliters. Displays the current Dispense/Meter Rate setting in microliters per second. Displays the current Priming Rate setting in microliters per second. Displays the current mode (Prime / Dispense / Meter) Displays the current direction (Forward/ Reverse) Displays the current Drawback Volume setting in microliters. Displays the current Drawback Rate setting in microliters per second. Displays the current Drawback Dwell setting in seconds. Displays the current configuration (1-25) or "MODIFIED". Displays the current permission level. Starts the current mode of operation. Stops the current mode of operation. Indicates the state of the READY output in the PLC Interface. Switches to the Fault screen. Switches to the Configuration screen. Switches to the Volume & Rate screen. Figure 3.10 Main Screen P03L008K IVEK Corp. 10 April, 2013

11 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-11 The "START" button will start the system using the current parameters. The system will operate until the cycle is completed or the "STOP" button is pressed. The "READY" box indicates the state of the READY output in the PLC Interface. If the system is not Ready, the icon will change color and display "BUSY". The current configuration and permission level are displayed. The Configuration number will normally be a number from 1 to 25 indicating the current configuration. "MODIFIED" will be displayed when the access level was Manual or Supervisor and was then changed to Operator without a configuration being selected. This indicates the parameters displayed may not be the same as one of the 25 configurations Volume & Rate Screen (Figure 3.11) The Volume & Rate screen displays the primary operating parameters for the configuration selected in the Configuration screen. This screen is used to change parameters for custom dispenses. The current permission level determines which buttons are currently available as shown in Figure NOTE Parameters changed in this screen will not be saved if a different configuration is selected. The system can be operated from this screen. The Fault, Drawback and Main screens are accessible from this screen. Volume Volume (in microliters) is the amount of liquid pumped for one dispense operation. To change the Volume value; 1. Press the "SET" button. 2. The keypad appears with the minimum and maximum settings displayed. 3. Enter the value using the number keypad. 4. Press the "ENTER" button. Disp/Meter Rate The Disp/Meter rate (in microliters per second) is the amount of liquid pumped per second during the dispense and meter operations. To change the Disp/Meter Rate value; 1. Press the "SET" button. 2. The keypad appears with the minimum and maximum settings displayed. 3. Enter the value using the number keypad. 4. Press the "ENTER" button. Priming Rate The Priming rate (in microliters per second) is the amount of liquid pumped per second during the priming operations. To change the Priming Rate value; 1. Press the "SET" button. 2. The keypad appears with the minimum and maximum settings displayed. 3. Enter the value using the number keypad. 4. Press the "ENTER" button. Operating Mode The "PRIME / DISPENSE / METER / BUBBLE CLEAR" button indicates the current mode of operation. The button will display only the current mode. Prime mode produces a continuous cycle to pump fluid in one direction. Prime is used to fill the system with fluid in preparation for actual operation, empty the system of fluid, and flush the system for cleaning. Dispense mode is used to deliver a specific volume of fluid at a specific rate. The current settings for the fluid direction determine the direction of fluid flow. Meter mode is used to deliver fluid at a specific rate for the period of time the system is active. Bubble Clear mode is a sequence of volume displacement and valving used to dislodge air bubbles in the pump chamber. To change the Operating Mode; 1. Press the button displaying the current mode. 2. The button will cycle through PRIME / DISPENSE / METER / BUBBLE CLEAR. 3. Stop at the desired mode. Liquid Direction The "FORWARD / REVERSE" button indicates the current liquid direction. The button only displays the current direction. To change the Liquid Direction; 1. Press the button displaying the current direction. 2. The direction button will change to display the new direction Drawback Screen (Figure 3.12) The Drawback screen displays parameters which control Drawback operation settings for the configuration selected in 10 April, 2013 IVEK Corp. P03L008K

12 Page 3-12 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE The Volume and Rate screen is used to set volume and rate parameters (See below for a description of each section) Operator Manual Supervisor Displays the current Volume setting in microliters. Pressing enables the entry keypad for changing the setting. Displays the current Dispense and Meter Rate setting in microliters per second. Pressing enables the entry keypad for changing the setting. Displays the current Priming Rate setting in microliters per second. Pressing changing the setting. Displays the current operating mode. When pressed toggles between Prime, Dispense, Meter and Bubble Clear. Starts the current mode of operation. Stops the current mode of operation. enables the entry keypad for Indicates the state of the PLC Interface READY output. Loads all channels. Indicates current selected pump size. Indicates a current fault condition and when pressed switches to the Fault Screen. Switches to the Drawback screen. Switches to the Main screen. Displays the current direction. When pressed toggles between Forward and Reverse. Figure 3.11 Volume And Rate Screen P03L008K IVEK Corp. 10 April, 2013

13 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-13 The Drawback screen is used to set drawback and configuration parameters (See below for a description of each section) Operator Manual Supervisor Displays the current Drawback Volume setting in microliters. Pressing enables the entry keypad for changing the setting. Displays the current Drawback Rate setting in microliters per second. Pressing enables the entry keypad for changing the setting. Displays the current Drawback Dwell setting in seconds Pressing enables the entry keypad for changing the setting. Displays the Load parameter. When pressed toggles between Load Empty, Load Every, Load Manual. Displays the Porting setting. When pressed toggles between Port A and Port B. Displays the current Valving Speed setting in steps per second. Pressing enables the entry keypad for changing the setting. Switches to the Params A screen. Switches to the Volume and Rate screen. Figure 3.12 Drawback Screen 10 April, 2013 IVEK Corp. P03L008K

14 Page 3-14 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE the Configuration screen. This screen is used to change drawback parameters for custom dispenses. Drawback is a controlled reverse flow at the end of a dispense to improve volume repeatability when 'stringy' liquids are being dispensed. At the end of the dispense cycle, the motor will reverse pulling the liquid back into the liquid line. The Controller Module will automatically compensate for the drawback volume, the dispense volume value must not be adjusted. The current permission level determines which buttons are currently available as shown in Figure NOTE Parameters changed in this screen will not be saved if a different configuration is selected. The Params A and Vol & Rate screens are accessible from this screen. Drawback Volume Drawback Volume (in microliters) is the amount of liquid pulled back into the Pump Module for one Drawback operation. To change the Drawback Volume value; 1. Press the "SET" button. 2. The keypad appears with the minimum and maximum settings displayed. 3. Enter the value using the number keypad. 4. Press the "ENTER" button. Drawback Rate The Drawback Rate (in microliters per second) is the speed the liquid is drawn back into the Pump Module. To change the Drawback Rate value; 1. Press the "SET" button. 2. The keypad appears with the minimum and maximum settings displayed. 3. Enter the value using the number keypad. 4. Press the "ENTER" button. Drawback Dwell The Drawback Dwell (in seconds) is the amount of time between the end of the Dispense or Meter operation and the start of the Drawback operation. To change the Dwell value; 1. Press the "SET" button. 2. The keypad appears with the minimum and maximum settings displayed. 3. Enter the value using the number keypad. 4. Press the "ENTER" button. NOTE The remaining items are not related to drawback. Valving Speed Valving Speed (in steps per second) is the rotational speed of the piston during valving. To change the Valving Speed; 1. Press the "SET" button. 2. The keypad appears with the minimum and maximum settings displayed. 3. Enter the value using the number keypad. 4. Press the "ENTER" button. Load The "LOAD" button indicates the current Load setting (Load Empty, Load Every, Load Manual, refer to section for a description). The button only displays the current setting. To change the Load setting; 1. Press the button displaying the current setting. 2. The button will change to display the new setting. Port The "PORT" button indicates the current Port setting (Port A, Port B, refer to section for a description). The button only displays the current setting. To change the Port setting; 1. Press the button displaying the current setting. 2. The button will change to display the new setting Params A Screen (Figure 3.13) The Params A screen displays certain system parameters and user information. This screen is used to clear the totalizer and change the permission level. The current permission level determines which buttons are currently available as shown in Figure The Clear Totalizer, Params B, and Main screens are accessible from this screen. Totalizer The "TOTALIZER" box displays the volume dispensed (in microliters) for the channel indicated in the "CHANNEL" box. P03L008K IVEK Corp. 10 April, 2013

15 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-15 The Params A screen displays system parameters and user information (See below for a description of each section) Operator Manual Supervisor Displays the total volume dispensed in microliters for the selected channel. Displays the selected channel for viewing the Totalizer value. Pressing enables the entry keypad to change channels. Pressing selects the previous channel. Pressing selects the next channel. Switches to the Clear Totalizer screen. When pressed, clears the selected channels totalizer value. Displays the current permission level. Displays the current Prime Duration setting in sec. Pressing enables the entry keypad to change the setting. Displays the current Ready Out Configuration setting. Pressing enables the entry keypad to change the setting. Switches to the Params B screen. Switches to the Main screen. Changes the permission level. Figure 3.13 Params A Screen 10 April, 2013 IVEK Corp. P03L008K

16 Page 3-16 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE To clear the Totalizer for the selected channel; 1. Press the "CLEAR SELECTED TOTALIZER" button. To clear the Totalizer for all channels; 1. Press the "CLEAR ALL TOTALIZERS" button. 2. The Clear Totalizer screen is displayed. 3. Press the "CLEAR TOTALIZERS FOR ALL CHAN- NELS" button to clear the totalizer or press the "PARAMS A SCREEN" button to cancel. Change Permission The "CHANGE PERMISSION" button displays the keypad for changing the permission level to the software. There are three levels; Supervisor, Manual, and Operator (Refer to section ). To change the Permission level; 1. Press the "CHANGE PERMISSION" button. 2. The keypad will appear. 3. Enter the password code for the desired access level. 4. Confirm the display shows the desired level. Prime Duration The Prime Duration (in seconds) is the maximum amount of time the system will operate during one Prime operation. To change the Prime Duration; 1. Press the "SET" button. 2. The keypad appears with the minimum and maximum settings displayed. 3. Enter the value using the number keypad. 4. Press the "ENTER" button. Ready Out Config The ready Out Configuration determines when the Ready Out signal will be false. The signal is always false during dispense and meter operations. Both the "System Ready" and optional "Independent Channel Ready" signals are configured with this value. The following optional settings are available: System/Channel Description 2 Priming (System Ready also false) System System 8 Any fault true, reference required (System Ready also false) 32 Priming (Channel Ready also false) Channel 128 Any fault true, reference required (Channel Channel Default Ready also false) 138 System not ready if in Prime, fault or reference required. Channel not ready if fault or reference required. Add the desired values listed above to determine the correct value for the "Ready Out Config" parameter. To change the Ready Out Config; 1. Press the "SET" button. 2. The keypad appears with the minimum and maximum settings displayed. 3. Enter the value using the number keypad. 4. Press the "ENTER" button Params B Screen (Figure 3.14) The Params B screen displays additional parameters not displayed in the Params A screen. This screen is used to change the permission level and exit the software. The current permission level determines which buttons are available as shown in Figure Information is displayed which may be requested by IVEK's Technical Service Department when locating the source of problems. The software version of the Master Plug-In, Channel Plug-In(s) and Touchscreen are displayed. The serial number of the Controller Module is stored in the Touchscreen (entered during manufacture at IVEK Corporation). The Exit and Main screens are accessible from this screen. Exit NOTE There is no need to exit the Touchscreen program before powering down the Controller Module. IVEK Technical Service may have you exit the program for calibration or troubleshooting. The "EXIT" button is the only way to exit the software. To exit the software; 1. Press the "EXIT" button. 2. The Exit screen will appear. 3. Press "EXIT" to exit the software or "DON'T EXIT GO TO MAIN SCREEN" to cancel. Change Permission The "CHANGE PERMISSION" button displays the keypad for changing the permission level to the software. There are three P03L008K IVEK Corp. 10 April, 2013

17 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-17 The Params B screen displays additional system parameters and user information (See below for a description of each section) Operator Manual Supervisor Displays the software version for the Master and Channel 1 boards. Displays the current user access level. Switches to the Main screen. Displays the Controller Module serial number. Displays the software version for the touchscreen. Displays the current Pump Size. When pressed toggles between AAAA, AAA, AA, A, B, C and D. Displays the Increment Volume, Maximum Volume and Maximum Rate in microliters for the selected Pump Size. Changes the user permission level. Switches to the Exit screen. Figure 3.14 Params B Screen 10 April, 2013 IVEK Corp. P03L008K

18 Page 3-18 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE levels; Supervisor, Manual, and Operator. (Refer to section ) To change the Permission level; 1. Press the "CHANGE PERMISSION" button. 2. The keypad will appear. 3. Enter the password code for the desired access level. Pump Size The "PUMP SIZE" button indicates the current pump size selection. The button will display only the current size. To change the Pump Size; 1. Press the button displaying the current size. 2. The button will cycle through AAAA / AAA / AA / A / B / C / D. 3. Stop at the desired size Faults Screen (Figure 3.15) The Faults screen displays fault information and is used to reference the system. All the buttons on this screen are accessible by all permission levels. The Main screen is accessible from this screen. Faults When the Fault screen is displayed, the fault on one channel will be displayed. The "CHANNEL" box displays the faulted channel and the "DESCRIPTION" box displays the fault message. If no faults exist, the "CHANNEL" box will be "0" and the "DESCRIPTION" box will be empty. Press "CLEAR AND REFERENCE" to clear the fault and reference the pump. The next fault (if one exists) and associated channel will then be displayed in the "CHANNEL" and "DESCRIPTION" boxes. To clear all the faults and reference the pumps press the "CLEAR FAULTS AND REFERENCE ALL CHANNELS" button. NOTE Faulted channels must be referenced after the fault is cleared. Stop the "System Trigger In" signal in the PLC Interface before referencing using either "CLEAR AND REFERENCE' or the "CLEAR FAULTS AND REFERENCE ALL CHANNELS" buttons. Communication Box The communication box displays the status of the electrical connection between the Touchscreen and the Master Circuit Card. When the Touchscreen is communicating with the Master Plug-In the message "GOOD COMMUNICATION TO MAS- TER CIRCUIT BOARD" is displayed. When there is no communication the message "CONNECTION TO MASTER PLUG-IN IS INTERRUPTED" is displayed Clear Totalizer Screen (Figure 3.16) The Clear Totalizer screen is a backup screen in case the "CLEAR ALL TOTALIZERS" button on the Params A screen was accidently pressed. All the buttons on this screen are accessible by all permission levels. To clear the totalizers press the "CLEAR TOTALIZERS FOR ALL CHANNELS" button. Press the "PARAMS A SCREEN" button to return without clearing the totalizers or after all totalizers have been cleared Exit Screen (Figure 3.17) NOTE There is no need to exit the Touchscreen program before powering down the Controller Module. IVEK Technical Service may have you exit the program for calibration or troubleshooting. The Exit screen is a backup screen in case the "EXIT" button on the Params B screen was accidently pressed. All the buttons on this screen are accessible by all access levels. To exit the software press the "EXIT" button. Press the "DON'T EXIT GO TO THE MAIN SCREEN" button to escape without exiting PLC Interface The PLC interface provides connections between the Controller Module and the customer's PLC. Trigger Input, Ready Out and Fault Out signals are communicated to and from the PLC Signal Functions System Trigger In - The 'System Trigger In' signal initiates a cycle. The trigger signal has no effect in Prime mode. P03L008K IVEK Corp. 10 April, 2013

19 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-19 The Fault screen Displays and clears faults (See below for a description of each section) Displays the fault description for the indicated channel. Blank if no faults are present. Displays the channel with the fault. Will be "0" if none are faulted. Clear and References indicated channel. Clears all faults. Clear Faults and Reference all channels. Displays Master Board communications status. Switches to the Main screen. Figure 3.15 Fault Screen 10 April, 2013 IVEK Corp. P03L008K

20 Page 3-20 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE The Clear Totalizer screen clears all channels values (See below for a description of each section) Clears all totalizer values. Switches to the Params A screen. Figure 3.16 Clear Totalizer Screen P03L008K IVEK Corp. 10 April, 2013

21 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-21 The Exit screen allows returning to the Main screen or exiting the software (See below for a description of each section) Returns to the main screen. Operator Manual Supervisor Exits the Touchscreen software. NOTE There is no need to exit the Touchscreen program before powering down the Controller Module. IVEK Technical Service may have you exit the program for calibration or troubleshooting. Figure 3.17 Exit Screen 10 April, 2013 IVEK Corp. P03L008K

22 Page 3-22 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Dispense Mode - When the Controller Module is properly configured for Dispense mode, all channels are triggered at the transition when a signal is applied to the system trigger. If a channel is disabled, faulted, requires a reference, that channel is not triggered. (see section ) Meter Mode - When the Controller Module is properly configured for Meter mode, all channels are triggered as long as a signal is applied to the system trigger (until the pump chamber empties). If a channel is disabled, faulted, requires a reference, that channel is not triggered. (see section ) System Ready Out - The 'System Ready Out' signal indicates the active/idle state of the Controller Module. All channels must be ready for this output to be "true". This output is false if any channel is not 'ready'. The Params A screen "READY OUT CONFIG" button (refer to section ) is used to define ready for both the system ready and optional independent channel ready outputs. System Fault Out - The 'System Fault Out' signal indicates that a fault has been detected in the operation of an Motor/ Base Module. This output is complemented, i.e., the output is true when no fault exists on any channel, and is false when one or more channels are faulted. System Load Required Out - The 'System Load Required Out' signal indicates if any channel requires a load cycle. This output is 'true' when no enabled channels require a load. This output is complemented i.e., the output is false if any enabled channel requires a load or is in the process of loading (negative true logic) Signal Levels All signals are optically isolated. The power for all signals is provided by the customer s equipment. All inputs accept a 24 VDC signal and require 20 ma. All outputs conduct when the signal is true and do not conduct when the signal is false (see FAULT OUT). Outputs can switch a signal of up to 24 VDC and 50 ma. The output consists of the emitter and collector connections to an IC opto-isolator Connections All connections are through a 9-pin circular plastic connector, with the mating connector and pins supplied with the unit. The connector on the Controller Module is an AMP CPC Series The connector has the pin layout as shown in Table 3.1. Table 3.1 PLC Interface PIN SIGNAL PIN SIGNAL 1 TRIGGER IN + 6 FAULT OUT - 2 TRIGGER IN - 7 LOAD REQ + 3 READY OUT + 8 LOAD REQ - 4 READY OUT - 9 not used 5 FAULT OUT Operating Modes There are several different modes of operation which provide the Controller Module with its vast functional flexibility. Volume commands for the Multispense 2000 use microliters. Rate commands are in microliters per second Prime Prime mode produces a continuous cycle to pump fluid in one direction. The current setting for the liquid direction determines the direction of the fluid flow. The operating mode and liquid direction setting can be viewed in the Main screen (Figure 3.10). Pumping is started using the "START" button in the Main or Volume & Rate screens (Figures 3.9 or 3.11). The pumping will continue until the "STOP" Button is pressed or until the maximum time set with the "PRIME DURATION" button in the Params A screen (Figure 3.13) is reached. The time-out insures a communications problem won t result in the pumps operating forever. Prime is used to fill the system with fluid in preparation for actual operation, empty the system of fluid, and flush the system for cleaning. The flow rate for priming is set in the Volume & Rate screen (Figure 3.11) and is separate from the Dispense and Meter rate. Generate a new configuration if the Priming parameters will remain constant. Volume pumped during prime operation does not accumulate on the totalizer viewed in the Params A screen (Figure 3.13) Dispense Dispense mode is used to deliver a specific volume of fluid at a specific rate. The current setting for the liquid direction determines the direction of the fluid flow. The operating mode and liquid direction setting can be viewed in the Main screen (Figure 3.10). Pumping can be started "START" button in the Main or Volume & Rate screens (Figures 3.10 or 3.11). The dispense cycle will continue until the volume set using the "VOLUME Strokes button in the Volume & Rate screen P03L008K IVEK Corp. 10 April, 2013

23 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-23 (Figure 3.11) has been delivered, unless the "STOP" button is pressed. The flow rate and volume for dispensing are set in the Volume & Rate screen (Figure 3.11) and is separate from the Prime rate. Generate a new configuration if the Dispense parameters will remain constant. Volume pumped during dispense operation accumulates on the totalizer which is viewed Params A screen (Figure 3.13) Meter Meter mode is used to deliver fluid at a specific rate for a period of time determined by hardwired input signals or through the Touchscreen. The operating mode and liquid direction setting can be viewed in the Main screen (Figure 3.10). The most accurate and repeatable method to control metering operation uses the hardwired inputs. Pumping will start when the hardwired signal is present and will stop when the hardwired signal stops. Pumping can also be operated with the "START" and "STOP" buttons in the Main or Volume & Rate screens (Figures 3.10 or 3.11). In meter mode, the pump will stop as soon as possible without regard to the reference position of the pump. If switching from Meter to Dispense mode, the first dispense must be wasted. This will align the pump to the reference position. The flow rate and metering is set in the Volume & Rate screen (Figure 3.11) and is separate from the Prime rate. Generate a new configuration if the Meter parameters will remain constant. Volume pumped during dispense operation accumulates on the totalizer which is viewed Params A screen (Figure 3.13). Volume is limited to the available volume in the pump chamber Bubble Clear Bubble clear mode is a sequence of volume displacement and valving used to dislodge air bubbles in the pump chamber and move them out through the discharge port. This is used when initially priming the system to aid in eliminating air bubbles which have a detrimental effect on accuracy and repeatability. The bubble clear cycle can only be operated with the "START" and "STOP" buttons in the Main or Volume & Rate screens (Figures 3.10 or 3.11). Bubble Clear cannot be started with the PLC inputs. If the Load parameter is set to Load Empty or Load Every, a load cycle will automatically be initiated at the end of a bubble clear cycle. The flow rate for Bubble Clear is set in the Volume & Rate screen (Figure 3.11) using the PRIMING RATE button and is separate from the Dispense and Meter rate. Generate a new configuration if the Bubble Clear parameters will remain constant Other Operating Sequences Reference - Under certain conditions the controller may require a reference cycle when a fault occurs because it does not sense the rotary position of the piston. When the "CLEAR AND REFERENCE" or "REF ALL" buttons (Figure 3.15) are pressed, the piston will find the rotary home and stop at this position. A reference cycle may be required after any fault before a command resulting in motion of the pump is accepted. Drawback - Drawback is a controlled reverse flow at the end of a dispense or meter operation to improve volume repeatability when stringy fluids are being dispensed. If no drawback is required, the drawback volume is simply set to 0. The Drawback settings are done in the Drawback screen (Figure 3.12). When drawback is used, the "VOLUME" button specifies the net fluid displaced, the actual forward motion is the sum of the specified dispense volume and the drawback volume. The flow rate during drawback as well as the dwell (time between the forward and reverse portions of the cycle) are specified with the "DRAWBACK RATE" and "DRAW- BACK DWELL" buttons respectively. Load - The load cycle is used to refill the pumping chamber with fluid after dispensing or metering. The piston will valve to the inlet port, fill the pump chamber with fluid, and valve back to the discharge port. The system can be configured to start a load cycle on either of three conditions; empty, every or manual. When the system is configured for load empty, a load cycle will start when the pump is idle and the remaining volume in the pump chamber is less than the volume required for the next dispense. When the system is configured for load every, a load cycle will start at the completion of every dispense or meter operation. When the system is configured for 'load manual', a load cycle will only be initiated when the "LOAD ALL" button in the Volume And Rate screen is pressed. 10 April, 2013 IVEK Corp. P03L008K

24 Page 3-24 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Operating Parameters Status Information Parameters are divided into a number of categories. This section provides a description of each command in the parameter that best fits its description Pump Control The following parameters control the specific operation of the Motor/Base Module. All of the following parameters are set for the individual channel of each Motor/Base Module. The channels can have the same or different values for each parameter. Rate For Dispense And Meter Operation - One parameter command is used to control the fluid flow rate for both dispense and meter mode. A two parameter version of the rate command is available to allow changes in the rate to take effect while the Motor/Base Module is in motion. Dispense Volume - This parameter is used to specify the volume of fluid dispensed during dispense operation. The dispense volume indicates full revolutions of the pump. Rate For Prime, Load, And Bubble Clear Operation - One parameter is used to control the fluid flow rate for prime mode, Bubble Clear mode and during load operations. Direction - The direction of the fluid flow is normally forward, but can be reversed to empty fluid back into the supply. Port - The selected port (normally considered the discharge port) can be changed to allow desired fluid flow direction for different mounting orientations of the Actuator Module. Drawback - Three parameters are specified to describe drawback operation. These are the drawback volume, the fluid flow rate during drawback, and the dwell (time delay) between the dispense and drawback portions of the cycle. Keylock - Operation of the channel in any mode can be controlled using the ENABLE switch on the front panel of the Channel Plug-In. If the ENABLE switch is in the LOCKOUT position, the serial interface command will not be allowed to enable the channel. Time Limit For Prime - In order to prevent the system from continually running if the communications are interrupted during a prime operation, priming is limited to a duration specified by a parameter. Valving Speed - The rotational speed of the piston during valving can be lowered if required to pump highly viscous fluids Faults The response to all commands to a particular channel will respond with fault or warning information if applicable. The fault will be indicated until faults are cleared on that particular channel. A fault present on a channel other than the one addressed by the current command will be indicated, but neither the faulted channel address nor the exact type of fault will be indicated. A fault is the result of improper operation of the Motor/Base Module being detected. Warnings indicate an error in the command, or a condition which requires attention before operation can be initiated. Clear Faults - After a fault, the clear faults command and reference command must be issued prior to any commands which would cause motion in the Motor/Base Module. The clear faults command responds with the identity of the fault being cleared and additional information for certain faults. NOTE After a fault is cleared, a reference MUST BE issued to insure proper operation of the channel that was faulted. The channel that was faulted WILL NOT respond to any motion command until the reference command has successfully. 3.3 INSTALLATION General operating practices provide the best guidelines for locating the components of the system. The Controller Module should be located for ease of use during all phases of operation and maintenance. If both 20-pitch and 40-pitch Actuator Modules are used on a single Controller Module, insure the Actuator Module is connected to the correct Channel Plug-In. Refer to Figure 3.20 for the Channel Plug-In and Chapter 5 for the Actuator (or Chapter 6 if custom) identification information. 3.4 OPTIONS IVEK Corporation offers a variety of options to best meet the customers needs. Following is a list and description of available options for the Controller Module. Refer to the Title Section of this manual for the list of options provided with this system. P03L008K IVEK Corp. 10 April, 2013

25 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page PLC Interface With Independent Channel Ready Ready output logic signals for each of the channels are added to the PLC interface. The ready output signals for each channel permit independent monitoring of the ready versus busy status of an individual channel using a logic signal rather than a command through the serial interface. This section describes the differences between the standard PLC Interface and this option Signal Functions Channel <n> Ready Out - The 'Channel <n> Ready Out' signal indicates the active/idle state of each channel. The "READY OUT CONFIG" button in the Params A screen (Figure 3.13) is used to define ready for both the system ready and channel ready outputs Connections Different connections are used based on the number of channels. See Chapter 4 for information specific to your Controller Module PLC Interface With Independent Channel Trigger Input trigger signals for each channel are added to the PLC interface. The trigger input signals for each channel permit independent triggering of an individual channel using a logic signal rather than a command through the serial interface. This section describes the differences between the standard PLC Interface and this option Signal Functions Channel <n> Trigger In - The 'Channel <n> Trigger In' signal initiates a cycle for each channel. A signal applied to this input will trigger the selected channel if the channel has Dispense or Meter mode selected. A channel will not be triggered if it is in Prime, is faulted, or requires a reference Connections Different connections are used based on the number of channels. See Chapter 4 for information specific to your Controller Module Touchscreen The touchscreen may either be in an enclosure or available for remote mounting. Refer to Figure 3.20 for Enclosure and Touchscreen dimension. The touchscreen weighs approximately 1.86 kilograms (4.1 pounds). Connections between the external touchscreen and Controller Module are with connectors. The addition of the external touchscreen adds an optically isolated serial interface which reduces problems from electrical noise Touchscreen Without Enclosure The system comes with a cable for connecting the Controller Module to the Touchscreen. The cable end with one connector connects to the "TOUCHSCREEN" connector on the rear of the Controller Module. The end with two connectors connects to the COM1 and Power connectors on the Touchscreen. Secure the COM1 connector with #4-40 x 1/8" retaining screws. Secure the Power connector with the retaining screws supplied on the connector. Do not connect to any other connectors on the rear of the Touchscreen. Make sure the ON/OFF slide power switch is in the "ON" position prior to use. The touchscreen must be mounted in a grounded metal enclosure to meet EMC requirements for CE. A grounded metal enclosure may also be required to meet other EMC requirements. For electrical safety considerations, be aware that the power supplied to the touchscreen by the Multispense controller is 24 volts DC. The touchscreen s faceplate is designed to the NEMA 4 (IP65 European standard) rating. You must mount the touchscreen in a similarly rated enclosure and use the supplied gasket to maintain this rating after installation. Route the cable between the touchscreen and the Multispense enclosure away from AC and high-noise DC wiring. You can safely operate the touchscreen at ambient air temperatures from 0 to 45 deg C (32 to 113 deg F). However, the temperature outside a protective enclosure is generally lower than the internal temperature. Thus, if the touchscreen is operating inside an enclosure at temperature levels above its rated ambient temperature, you will need to cool the enclosure. Select an enclosure that is large enough to allow free airflow in and around the touchscreen. You should allow a minimum of a 51mm (2") gap between the enclosure and the top, bottom, and sides of the touchscreen. Also, make sure that the surface of the enclosure on which the touchscreen is mounted is flat and free of raised or depressed areas. 10 April, 2013 IVEK Corp. P03L008K

26 Page 3-26 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE If the screen still appears to be blank or very dim, and the unit has been in operation continuously for a long time, the backlight bulb may need replacing. Refer to the Parker CTC User's Guide for detailed mounting instructions including a template for the enclosure cutout Touchscreen With Enclosure The system comes with a cable for connecting the Controller Module to the Touchscreen enclosure. The cable end with the male connector attaches to the "TOUCHSCREEN" connector on the rear of the Controller Module. The end with the female connector attaches to the connector on the Touchscreen cabinet. 3.5 MAINTENANCE No periodic maintenance is required on the Controller Module, beyond standard practices for electronic equipment. For Touchscreen maintenance, refer to Chapter 5 in the Computer Technology Corporation "POWERSTATION Model P1 User Guide" Assembly/Disassembly Procedures The Controller Module contains the following replaceable parts. Master Plug-In Main Power Fuse Channel Plug-In Master Plug-In (Figure 3.19 Item 1) CAUTION This is an electrostatic sensitive device. Electrostatic discharge can damage the board if not handled properly. Disassembly 1. Turn power OFF. 2. Remove the serial interface cable from the connector. 3. Loosen two captive screws securing the Master Plug- In to the chassis. 4. Grab the handle and slide the Master Plug-In straight out. Assembly 1. Slide the Master Plug-In into the chassis making sure it goes into the rear connector and secure with the two captive screws. 2. Connect the cable to the connector Channel Plug-In (Figure 3.19 Item 2) CAUTION This is an electrostatic sensitive device. Electrostatic discharge can damage the board if not handled properly. If both 20-pitch and 40-pitch Actuator Modules are used on a single Controller Module, insure the correct Channel Plug-In is used. Refer to the specification section following the Table of Contents for the Channel Plug-In Actuator Module identification chart. Disassembly 1. Turn power OFF. 2. Remove the cable from the connector. 3. Loosen four captive screws securing the Channel Plug- In to the chassis. 4. Grab the handle and slide the Channel Plug-In straight out. Assembly 1. Slide the Channel Plug-In into the chassis making sure it goes into the rear connector. Secure with the four captive screws. 2. Connect the cable to the connector Main Power Fuse (Figure 3.18) The main power fuse, located in either the Power Entry Module or the system fuse holder on the rear panel is replaceable. The proper fuse value is described in the Title Page section of this manual. Fuse holders for the Power Entry Module are available from IVEK Corporation for conversion to 5mm by 20mm fuses. For the system fuse holder, simply remove the old fuse and install a new one. For the Power Entry Module, use the following disassembly/assembly instructions. Disassembly 1. Turn power OFF. 2. Remove the power cord. P03L008K IVEK Corp. 10 April, 2013

27 MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page Using a small flat blade screwdriver, open the power entry module's cover. 4. Slide the fuse tray out and remove the fuse. Assembly 1. Install the new fuse into the fuse tray and slide the tray in. The arrow on the fuse holder should point to the right. 2. Close the power entry module's cover. 3. Connect the power cord Touchscreen (Figure 3.19) The Touchscreen is available in two configurations; either mounted in an IVEK Touchscreen enclosure or shipped without an enclosure for customer mounting. The following disassembly/assembly procedure is for the IVEK mounted configuration. This procedure may need to be altered for customer mounted configurations. Selection Cam Fuse Holder Disassembly 1. Turn power OFF. 2. Gain access to the rear of the touchscreen by removing the front panel of the enclosure which contains the touchscreen. After loosening the four captive screws that secure the front of the enclosure, be sure to support the front panel to avoid stress on the wiring. 3. Disconnect power cable connector (1) from Touchscreen (2) by pulling downward on cable connector (1). NOTE Do not remove the wires going into the connector. 4. Disconnect communications cable connector (5) from the COM1 port on Touchscreen (2). Do not pull on the wires to remove the connector. 5. Remove Touchscreen (2) from the enclosure by turning four screws (4) counter-clockwise about four turns, pushing bracket (3) forward (towards the front of the enclosure) pulling bracket (3) and screw (4) away from touchscreen (2). NOTE Make sure you hold the front of Touchscreen (2) to prevent it from falling out of the enclosure when the last bracket (3) is removed. 6. Slide Touchscreen (2) out the front of the enclosure. Figure 3.18 Power Entry Module Figure 3.19 Touchscreen Rear View 10 April, 2013 IVEK Corp. P03L008K

MULTISPENSE 900 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1. Table Of Contents. Section Description Page #

MULTISPENSE 900 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1. Table Of Contents. Section Description Page # MULTISPENSE 900 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1 Table Of Contents Section Description Page # 3. Multispense 900 W/Touchscreen Controller Module... 3-2 3.1 Description... 3-2 3.1.1 Front Panel

More information

MULTISPENSE 900 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1. Table Of Contents. Section Description Page #

MULTISPENSE 900 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1. Table Of Contents. Section Description Page # MULTISPENSE 900 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1 Table Of Contents Section Description Page # 3. Multispense 900 W/Touchscreen Controller Module... 3-2 3.1 Description... 3-2 3.1.1 Front Panel

More information

MULTISPENSE 2000 STYLE B CONTROLLER MODULE Page 3-1. Table Of Contents. Section Description Page #

MULTISPENSE 2000 STYLE B CONTROLLER MODULE Page 3-1. Table Of Contents. Section Description Page # MULTISPENSE 2000 STYLE B CONTROLLER MODULE Page 3-1 Table Of Contents Section Description Page # 3. MULTISPENSE 2000 STYLE B CONTROLLER MODULE...3 3.1 Description...3 3.1.1 Front Panel Controls & Indicators...3

More information

Table Of Contents. Section Description Page #

Table Of Contents. Section Description Page # DIGIFEEDER 2002 STYLE B CONTROLLER MODULE Page 3-1 Table Of Contents Section Description Page # 3. Digifeeder 2002 Style B Controller Module... 2 3.1 Description... 2 3.1.1 Front Panel Controls & Indicators...

More information

PDS100 Programmable Dispensing System SAFETY INSTRUCTIONS

PDS100 Programmable Dispensing System SAFETY INSTRUCTIONS PDS100 Programmable Dispensing System INSTRUCTION MANUAL SAFETY INSTRUCTIONS Before using any Fluid Metering, Inc. product read the following safety instructions as well as specific product specifications

More information

DIGITAL GEAR PUMP DRIVE OPERATING MANUAL: Model No.

DIGITAL GEAR PUMP DRIVE OPERATING MANUAL: Model No. OPERATING MANUAL: DIGITAL GEAR PUMP DRIVE Model No. 75211-70 Digital Gear Pump Drive 75211-70 A-1299-1142 Edition 01 Cole-Parmer 1-800-323-4340 ((U.S. and Canada only) 11 (847) 549-7600 (Outside U.S.)

More information

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data: Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

PDS-100 Programmable Dispensing System

PDS-100 Programmable Dispensing System PDS-100 Programmable Dispensing System INSTRUCTION MANUAL OVERVIEW The PDS-100 is a precision system capable of dispensing or pumping fluids ranging from 2.5 ul per dispense or 8 ul/min continuous (Single

More information

GOLANDER PUMP. Operation Manual. For Microflow Variable-Speed Peristaltic Pump BT50S/BT102S.

GOLANDER PUMP. Operation Manual. For Microflow Variable-Speed Peristaltic Pump BT50S/BT102S. GOLANDER PUMP Operation Manual For Microflow Variable-Speed Peristaltic Pump BT50S/BT102S info@golanderpump.com http://golanderpump.com 1-678-587-8806 Contents Safety Cautions... 1 1 Description... 1 2

More information

Sidewinder Pumps Inc. AC Timer/Controller

Sidewinder Pumps Inc. AC Timer/Controller Sidewinder Pumps Inc. AC Timer/Controller Page 1 of 12 Rev 032417 Table of Contents 1. Warnings-------------------------------------------------------------------------------------------------- 3 1.1.

More information

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE... TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE... 2 1.0 General Information... 3 1.1 System Components... 3 1.2 Specifications... 3 1.2.1 Torque Ranges... 3 1.2.2 Electrical Specifications...

More information

Instruction Manual. ROYTRONIC EXCEL Series AD9 Programming Guide Electronic Metering Pumps

Instruction Manual. ROYTRONIC EXCEL Series AD9 Programming Guide Electronic Metering Pumps Instruction Manual ROYTRONIC EXCEL Series AD9 Programming Guide Electronic Metering Pumps For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location:

More information

Automated Analytical Syringe User Manual

Automated Analytical Syringe User Manual XR Every One an Expert Automated Analytical Syringe User Manual WARNING Only trained laboratory personnel that have read this manual and the warnings and cautions contained in it should operate the evol.

More information

Installation and operation manual ReciFlow Gas

Installation and operation manual ReciFlow Gas Installation and operation manual ReciFlow Gas 1 1. Measurement principle... 3 2. Installation... 5 3. Operation... 7 4. Electrical interfaces... 11 5. Communication protocol... 14 6. Software update and

More information

DMX 2X1 / 3X1 MERGER USER GUIDE Pg 1

DMX 2X1 / 3X1 MERGER USER GUIDE Pg 1 DMX 2X1 / 3X1 MERGER USER GUIDE Pg 1 DMG OVERVIEW The DMG is a 1~3 input 1 output merger with versatile uses. Combines two or more signals or universes into one universe, by a selected mode type; HTP (Highest

More information

NETRONICS HS3500 CONTROLLER

NETRONICS HS3500 CONTROLLER NETRONICS HS3500 CONTROLLER CUSTOMER NAME CONTROLLER SERIAL # CONTROLLER PART # PERSONALITY SWITCH SETTINGS BULLET PRESS CONFIGURATION DELIVERY DATE Contact the factory for help setting up your application.

More information

MODEL 801R REMOTE CONTROL MICROPHONE PREAMPLIFIER

MODEL 801R REMOTE CONTROL MICROPHONE PREAMPLIFIER OWNERS MANUAL MODEL 801R REMOTE CONTROL MICROPHONE PREAMPLIFIER Software version 1.4 PO Box 204 Boulder, CO 80306 tel:303.443.7454 fax: 303.444.4634 http://www.gracedesign.com Revision B January, 2000

More information

LC-110/H. Reference Manual

LC-110/H. Reference Manual LC-110/H Reference Manual 1. Introduction...1 1.1 Customer Service...1 1.2 Standard Equipment...2 1.3 Safety information...2 2. Calibrator Interface and Operation...5 2.1 Milliamp Source...6 2.2 Milliamp

More information

Integrated Stepper Drive & Motor

Integrated Stepper Drive & Motor SMD23 Integrated Stepper Drive & Motor Manual #: 940-0S050 User Manual AMCI Motion Control Products Important User Information The products and application data described in this manual are useful in a

More information

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000 GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000 Instruction Manual D2-3342-2 The information in this manual is subject to change without notice. Throughout this manual, the

More information

Quick Start Guide. January EAZ0081L02A Rev. A

Quick Start Guide. January EAZ0081L02A Rev. A Quick Start Guide January 2014 EAZ0081L02A Rev. A Trademarks Snap-on and Vantage Ultra are trademarks of Snap-on Incorporated. All other marks are trademarks or registered trademarks of their respective

More information

FLOW MONITOR. Sage Design Corporation 65A Mall Drive Commack, N.Y (631) Pn. (631) Fax. Models SFM 3 and 4

FLOW MONITOR. Sage Design Corporation 65A Mall Drive Commack, N.Y (631) Pn. (631) Fax. Models SFM 3 and 4 FLOW MONITOR Sage Design Corporation 65A Mall Drive Commack, N.Y. 11725 (631) 499 4111 Pn. (631) 499 1888 Fax Models SFM 3 and 4 Paragraph CONTENTS Page Introduction I-1 Section 1 Installation 1-1 1.1

More information

Commercial and Residential Turntables. Motion Control User Manual Model MC-2

Commercial and Residential Turntables. Motion Control User Manual Model MC-2 Commercial and Residential Turntables Motion Control User Manual Model MC-2 Introduction The control system for the Carousel Turntables offers four modes of operation: 1. Manual 2. Camera 3. Preset 4.

More information

OPERATING MANUAL: L/S MODULAR DIGITAL PUMP DRIVES Model Nos. MASTERFLEX L/S 77301-40 77301-50 77301-60 77301-70 A-1299-1155 Edition 01 (US & Canada only) Toll Free 1-800-MASTERFLEX 1-800-637-3739 (Outside

More information

Removal and Installation8

Removal and Installation8 8 Screw Types 8-4 Top Cover Assembly 8-5 Left Hand Cover 8-6 Right Hand Cover 8-10 Front Panel Assembly 8-14 Left Rear Cover 8-15 Right Rear Cover 8-16 Extension Cover (60" Model only) 8-17 Media Lever

More information

SS2200 Remote Controller

SS2200 Remote Controller SS2200 Remote Controller General Purpose, DC Voltage General The SS2200 Remote Controller is a microprocessor-based programmable controller specifically designed to control single line and dual line centralized

More information

Monitored Power Supply INSTRUCTION MANUAL

Monitored Power Supply INSTRUCTION MANUAL Monitored Power Supply INSTRUCTION MANUAL C.E. Electronics Inc. 2107 Industrial Drive Bryan, OH 43506 (419) 636-6705 E-mail: sales@ceelectronics.com www.ceelectronics.com 2 i TABLE OF CONTENTS Quick Start

More information

S Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions

S Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions Cooper Power Systems Service Information S0-6- Applicable to VXE5 reclosers serial number 006

More information

GOLANDER PUMP BQ80S Microflow Variable-Speed Peristaltic Pump Operation Manual

GOLANDER PUMP BQ80S Microflow Variable-Speed Peristaltic Pump Operation Manual GOLANDER PUMP BQ80S Microflow Variable-Speed Peristaltic Pump Operation Manual info@golanderpump.com http://golanderpump.com 1-678-587-8806 Contents 1 Safety Cautions... 1 2 Introduction... 1 3 Functions

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

ABM International, Inc. Lightning Stitch Checklist 9/13/2013 ABM International, Inc. Lightning Stitch Checklist 9/13/2013 1) Piggy backed board assembly (1) Piggy back board assembly tested? Yes No 24v passed XB passed XA passed YB passed YA passed SAFE passed S/S

More information

ECLIPSE. Online and Downloadable Product Manuals and Quick Start Guides are available at

ECLIPSE. Online and Downloadable Product Manuals and Quick Start Guides are available at ECLIPSE LAUNDRY DISPENSER CONTROLLER Reference Manual Programming and Operation Online and Downloadable Product Manuals and Quick Start Guides are available at www.novacontrols.com/instructions.htm. Don't

More information

Peristaltic Cased Tube Pump

Peristaltic Cased Tube Pump Peristaltic Cased Tube Pump Selectable Output Control Functionality and Setup Version 1.0v-11/2016 Print-No. 01 Table of Contents 1. Introduction 2. Powering the Input/Output Port 2.1 Wiring for Local

More information

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

Sidewinder Pumps Inc. AC C1D2 Timer/Controller Sidewinder Pumps Inc. AC C1D2 Timer/Controller Page 1 of 14 Rev 4/26/17 Table of Contents 1. Warnings --------------------------------------------------------------------------------------------------

More information

PUMP DRIVE OPERA TING MANUAL: A Edition 01

PUMP DRIVE OPERA TING MANUAL: A Edition 01 OPERA TING MANUAL: PUMP DRIVE 77420-00 Pump Drive, shown with 77600-62 High Performance I/P Pump Head. 77420-00 A-1288-0990 Edition 01 1-800-637-3739 (U.S. and Canada only) 11 (847) 381-7050 (Outside U.S.)

More information

Torque Control Verifier

Torque Control Verifier Torque Control Verifier Instruction Manual Revision 1.2 September 2002 Please Read and Understand Instructions Before Attempting Installation Torque Control Verifier Contents: Quick Start Introduction

More information

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444 Product Manual 01504 (Revision B) Original Instructions RVDT Setup and Polarity Checking Tool for EG Governors T87444 Operation and Calibration Manual General Precautions Read this entire manual and all

More information

Dash HF Family High Speed Data Acquisition Recorder

Dash HF Family High Speed Data Acquisition Recorder Dash HF Family High Speed Data Acquisition Recorder QUICK START GUIDE (1) Introduction (2) Getting Started (3) Hardware Overview (4) Menus & Icons (5) Using the Dash HF (6) Setting Up the Display Appearance

More information

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR LC1 MANUAL 062114 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features Dimensions WIRING

More information

TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE...

TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... 3 1.0 General Information... 5 1.1 System Components... 5 1.2 Specifications... 5 1.2.1 Torque Ranges...

More information

Two Wire Back Flush Controller Installation and Operating Instructions Hit Products Corporation Lindsay, CA.

Two Wire Back Flush Controller Installation and Operating Instructions   Hit Products Corporation Lindsay, CA. Two Wire Back Flush Controller Installation and Operating Instructions Manufactured by: Hit Products Corporation Lindsay, CA. USA TABLE OF CONTENTS Specifi cations... 4 Wiring Connection... 5 Getting

More information

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process Answers to Chapter 2 Review Questions 1. To accept signals from the machine or process devices and to convert them into signals that can be used by the controller 2. To convert controller signals into

More information

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4 Table of Contents 1 ABOUT THIS GUIDE... 3 1.1 CONTACT INFORMATION... 3 2 ANTENNA INSTALLATION... 4 2.1 GENERAL INFORMATION... 4 2.2 SPECIFIC MOUNTING EXAMPLES... 5 2.3 CONNECTOR MOISTURE PROTECTION...

More information

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc. DLA DMX512 Analyzer DLA DLA-HH 1 Table Of Contents IMPORTANT SAFEGUARDS... 2 DLA OVERVIEW... 3 CONNECTION... 3 OPERATION... 3 HARDWARE SETUP... 4 DLA-HH (PORTABLE) LAYOUT... 4 CHASSIS LAYOUT... 4 DLA MENU

More information

DYNASCAN D-250 2D+ Ø DRO

DYNASCAN D-250 2D+ Ø DRO DYNASCAN D-250 2D+ Ø DRO The D-250 is an advanced digital readout system for performing three axes (two linear and one angular) geometrical measurement at very high level of precision and accuracy. Its

More information

2 in 1 LAN Tester and Multimeter Model:

2 in 1 LAN Tester and Multimeter Model: 2 in 1 LAN Tester and Multimeter Model: 72-8495 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This instrument is designed and manufactured

More information

OFP401P0189. Color Sensor. Operating Instructions

OFP401P0189. Color Sensor. Operating Instructions OFP401P0189 Color Sensor Operating Instructions Last update: 23 May 2013 2 Table of contents 1. Proper Use 4 2. Safety Precautions 4 3. EC Declaration of Conformity 4 4. Technical Data 5 4.1. Connection

More information

OPERATING MANUAL: L/S PUMP DRIVES Model Nos. MASTERFLEX L/S 07523-80 07523-80 07523-90 07551-00 07551-10 07575-10 A-1299-5151 Edition 01 Cole-Parmer 1-800-MASTERFLEX (627-8373) (U.S. and Canada only) 11

More information

2-PHASE STEPPING MOTOR DRIVER FE Z4 TRANSFER

2-PHASE STEPPING MOTOR DRIVER FE Z4 TRANSFER 2-PHASE STEPPING MOTOR DRIVER FE Z4 TRANSFER For Diaphragm Dosing Pumps FEM 1.02 / FEM 1.09 Controller board package, without pump: ID 157870 Operating and Installation Manual It is important to read and

More information

GOLANDER PUMP. Operation Manual. For Intelligent Flow Peristaltic Pump BT100L, BT300L, BT600L.

GOLANDER PUMP. Operation Manual. For Intelligent Flow Peristaltic Pump BT100L, BT300L, BT600L. GOLANDER PUMP Operation Manual For Intelligent Flow Peristaltic Pump BT100L, BT300L, BT600L info@golanderpump.com http://golanderpump.com 1-678-587-8806 Contents Safety Cautions... 1 1 Description... 1

More information

INTRODUCTION CT87E FEATURES AND CONTROLS

INTRODUCTION CT87E FEATURES AND CONTROLS INTRODUCTION The CT87E is a precision instrument used to monitor and record the presence or absence of voltage, light, or sound level such as what would be produced by an operating electric motor or compressor.

More information

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual The Flomatic FDHC-100 is a high performance Digital positioner intended to control AC actuators, providing 450 points of resolution with quarter turn actuators ranging from 2 sec to 120 sec and rated for

More information

User s Manual Pulse Encoder Interface Module OTAC-01

User s Manual Pulse Encoder Interface Module OTAC-01 Drive IT Low Voltage AC Drives User s Manual Pulse Encoder Interface Module OTAC-01 2 Safety WARNING! All electrical installation and maintenance work on the drive should be carried out by qualified electricians

More information

Time Mark Corporation Model 42A Pump Controller User s Guide

Time Mark Corporation Model 42A Pump Controller User s Guide Time Mark Corporation Model 42A Pump Controller User s Guide Graphic display User friendly Expandable Communications capable 2009 Time Mark Corporation. All rights reserved. Made in the U.S.A. Time Mark

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314 Instruction Manual 2in1 LAN Tester & Multimeter Model: 57314 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview Feature rich J+J multi-voltage smart electric actuator with LED status light and function conversion kits. J3C-S20 Overview The J3C-S20 multi-voltage smart electric valve actuator from the European electric

More information

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,

More information

AFCS Fluid Guard 2 Model

AFCS Fluid Guard 2 Model 671108 SRVIC GUID AFCS Fluid Guard 2 Model 343596 Alemite, LLC 167 Roweland Drive, Johnson City, Tennessee 37601 www.alemite.com Copyright 2016 by Alemite, LLC FORM: 671108 Version 1 Contents xplanation

More information

AD-7830 Servo Amplifier

AD-7830 Servo Amplifier Instruction Manual IM-0606 AD-7830 Servo Amplifier Table of Contents General Information... 2 Introduction... 2 Receiving/Inspection... 2 Storage... 2 Equipment Return... 2 Abbreviations Used in This Manual...

More information

GOLANDER PUMP Operation Manual For Intelligent Dispensing Peristaltic Pump BT100F-1

GOLANDER PUMP Operation Manual For Intelligent Dispensing Peristaltic Pump BT100F-1 GOLANDER PUMP Operation Manual For Intelligent Dispensing Peristaltic Pump BT100F-1 info@golanderpump.com http://golanderpump.com 1-678-587-8806 Contents Safety Cautions... 1 1 Description... 1 2 Functions

More information

Lightning Stitch Assembly

Lightning Stitch Assembly ABM International, Inc. 1 1.0: Parts List Lightning stitch motor and drive assembly (Qty. 1) Lightning stitch piggy backed controller board assembly (Qty. 1) Touchscreen (Qty. 1) 2 9-pin Serial cable (Qty.

More information

What s in the Box? REAR VIEW SAFETY

What s in the Box? REAR VIEW SAFETY TM 1 What s in the Box? 1 Full HD Color Infra-red Weather Proof Camera 1 Full HD 7" TFT LCD Color Monitor w/monitor Mount 1 Power Harness 1 66 Camera Cable 1 Power Connection Wire 1 Screw Kit for installation

More information

DIGITAL PUMP DRIVES OPERATING MANUAL: Model Nos.

DIGITAL PUMP DRIVES OPERATING MANUAL: Model Nos. OPERATING MANUAL: DIGITAL PUMP DRIVES Model Nos. 77922-18 77922-38 A-1299-7349 Edition 01 Argos Technologies (US only) Toll Free 1-800-866-8675 (Outside US & Canada) 1-800-622-0456 E-mail: info@argos-tech.com

More information

3000 Series Instructions Read Instructions Carefully!

3000 Series Instructions Read Instructions Carefully! Series Instructions Read Instructions Carefully! With buttons Without buttons CURTIS INSTRUMENTS, INC. Kisco Avenue, Mt. Kisco, NY 9 Tel. (9) 9 www.curtisinst.com. Technical Specifications. Electrical

More information

HI-POT TESTER. User s Manual

HI-POT TESTER. User s Manual HI-POT TESTER 7620 User s Manual Contents 1. Before Use... 1.1Electric Shock Avoidance... 4 1.2 Grounding... 4 1.3 AC Power Supply... 4 1.4 Connecting Test Leads... 4 1.5 Warm Up... 4 1.6 External Control...

More information

Pegasus Astro Dual Motor Focus Controller v3.0. Thank you for choosing our Dual Motor Focus Controller v3.0 (DMFCv3)

Pegasus Astro Dual Motor Focus Controller v3.0. Thank you for choosing our Dual Motor Focus Controller v3.0 (DMFCv3) Pegasus Astro Dual Motor Focus Controller v3.0 Thank you for choosing our Dual Motor Focus Controller v3.0 (DMFCv3) Pegasus Astro Copyright 2016 Documentation: Dec/16 Introduction The evolution of technology

More information

SNAP-IT-1U Installation Guide

SNAP-IT-1U Installation Guide Chapter 1 SNAP-IT-1U Installation Guide Introduction The SNAP-IT rack-mount unit is a packaged solution for attaching electrical, electronic, and mechanical devices to an Ethernet network. Once attached

More information

Data Sheet MEM 22. Absolute Encoder Multiturn

Data Sheet MEM 22. Absolute Encoder Multiturn Absolute Encoder Multiturn Features Resolution: Singleturn: up to 16,384 (14 Bit) steps per revolution Multiturn: up to 16,777,216 (24 Bit) revolutions Interface: SSI (synchron serial interface) or BiSS

More information

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A PMDX-105 I/O Option Riser Board User s Manual Date: 7 September 2004 PMDX Web: http://www.pmdx.com 7432 Alban Station Blvd., A105 Phone: +1 (703) 912-4991 Springfield, VA 22150-2321 USA FAX: +1 (703) 912-5849

More information

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual K0 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual Pneumatic Connection Single Acting Actuator (Spring Return): For single acting actuators Outlet Port 2 is to be plugged. Outlet Port

More information

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL v 1.0 Thanks for choosing the Intelligent temperature and humidity controller

More information

Zenith DS9000 Dispensing System

Zenith DS9000 Dispensing System Page Date: 04/2009 Zenith DS9000 Dispensing System Installation & Operation Manual Page 2 Table of Content Introduction... 3 Control Specification... 4 Wiring Diagram... 5 Wiring Instructions... 6 Field

More information

PFCS/Qualifier Interface

PFCS/Qualifier Interface PFCS/Qualifier Interface INSTRUCTION MANUAL CE Electronics Inc. 2107 Industrial Drive Bryan, OH 43506 (419) 636-6705 E-mail: sales@ceelectronics.com www.ceelectronics.com PFCS/Qualifier Interface PFCS/Qualifier

More information

A Issue A Original. Instruction Manual. nxds Serial Comms Interface

A Issue A Original. Instruction Manual. nxds Serial Comms Interface Instruction Manual A735-01-860 Issue A Original nxds Serial Comms Interface Description nxds6i nxds10i nxds15i nxds20i Item Number A735-01-983 A736-01-983 A737-01-983 A738-01-983 nxds6ic nxds10ic nxds15ic

More information

Pegasus Astro Dual Motor Focus Controller v2.0

Pegasus Astro Dual Motor Focus Controller v2.0 Pegasus Astro Dual Motor Focus Controller v2.0 Thank you for choosing Pegasus Astro - Dual Motor Focus Controller v2.0 (DMFC) Introduction The evolution of technology in astronomy requires a system which

More information

Silent Sentinel Solar Powered Advanced Warning Vehicle Mounted. Arrow Panels. Installation, Operation and Maintenance Manual (P/N )

Silent Sentinel Solar Powered Advanced Warning Vehicle Mounted. Arrow Panels. Installation, Operation and Maintenance Manual (P/N ) Silent Sentinel Solar Powered Advanced Warning Vehicle Mounted Arrow Panels Installation, Operation and Maintenance Manual (P/N 550-125-100) Harness Harness the the Power of of the Sun! 7620 Cetronia Road,

More information

PLC 23 DUAL MEDIA FILTERS 5 AND 6 SCADA SYSTEM OPERATION MANUAL. Revision 1.0 April 18, 2006

PLC 23 DUAL MEDIA FILTERS 5 AND 6 SCADA SYSTEM OPERATION MANUAL. Revision 1.0 April 18, 2006 PLC 23 DUAL MEDIA FILTERS 5 AND 6 SCADA SYSTEM OPERATION MANUAL Revision 1.0 April 18, 2006 PLC 23 DUAL MEDIA FILTERS 5 AND 6 SCADA SYSTEM OPERATION MANUAL Revision 1.0 April 18, 2006 Table of Contents

More information

Automation Interface Requirements for System I/O Interface of a DPC I Welding System

Automation Interface Requirements for System I/O Interface of a DPC I Welding System - 1 - Automation Interface Requirements for System I/O Interface of a DPC I Welding System The DPC I welding system offer several features that are intended to communicate with automation. These features

More information

Introduction to the FTA4000

Introduction to the FTA4000 Introduction to the FTA4000 This document will help you get started with your new FTA4000. The FTA4000 is optimized for contact angle measurements using very small droplets on small samples. It uses a

More information

RAIN BIRD RC-4Bi, RC-7Bi, RC-1260Bi SERIES INSTRUCTION MANUAL

RAIN BIRD RC-4Bi, RC-7Bi, RC-1260Bi SERIES INSTRUCTION MANUAL RAIN BIRD RC-4Bi, RC-7Bi, RC-1260Bi SERIES INSTRUCTION MANUAL DESCRIPTION OF CONTROLS Refer to Figure 1 Figure 1 A. HOUR DIAL with 23 CYCLE START PINS The HOUR dial contains 23 pins for rescheduling automatic

More information

G3 Series DeviceNet TM Technical Manual

G3 Series DeviceNet TM Technical Manual G3 Series DeviceNet TM Technical Manual Table of Contents G3 Series DeviceNet Technical Manual PAGE About DeviceNet... 3 Overview... 3 G3 DeviceNet Features... 3 Cabling and Drop Line Lengths (as defined

More information

VGC-3 Operating, Customizing And Troubleshooting

VGC-3 Operating, Customizing And Troubleshooting VGC-3 Operating, Customizing And Troubleshooting This manual covers operator instructions for operating the VGC-3 gate from the Operator Control. It assumes the gate has been installed, wired and setup

More information

SI3300. user and installation manual. 4-20mA/DC-Digital Display

SI3300. user and installation manual. 4-20mA/DC-Digital Display SI3300 4-20mA/DC-Digital Display The SI3300 is a member of the SI3000 Readout Family. All members of the family are marked SI3000 on the front panel. This manual is specifically for the SI3300 Model with

More information

SMD Series Integrated Stepper Driver and Motor Revision 1.3

SMD Series Integrated Stepper Driver and Motor Revision 1.3 The AMCI Integrated Stepper Motor and Microstepping Drive Combination represents the future of Stepper Motor Control applications. The SMD is a self-contained stepper motor and driver package, capable

More information

Operating Instructions ND 287

Operating Instructions ND 287 Operating Instructions ND 287 English (en) 8/2008 ND 287 Screen 1 2 3 4 5 ND 287 Front Panel 7 6 Controls and Displays 1 Status bar Current operating mode: Actual Value, Distance-To-Go. Current display

More information

DMX 2X1 / 3X1 MERGER USER GUIDE Pg 1

DMX 2X1 / 3X1 MERGER USER GUIDE Pg 1 DMX 2X1 / 3X1 MERGER USER GUIDE Pg 1 DMG OVERVIEW The DMG is a 1~3 input 1 output DMX merger with versatile uses. Combines two or more DMX signals or universes into one universe, by a selected mode type;

More information

GOLANDER PUMP. Operation Manual. For Intelligent Dispensing Peristaltic Pump BT101F, BT301F, BT601F.

GOLANDER PUMP. Operation Manual. For Intelligent Dispensing Peristaltic Pump BT101F, BT301F, BT601F. GOLANDER PUMP Operation Manual For Intelligent Dispensing Peristaltic Pump BT101F, BT301F, BT601F info@golanderpump.com http://golanderpump.com 1-678-587-8806 Contents Safety Cautions... 1 1 Description...

More information

Series B9 and C9 Electronic Metering Pumps. Instruction Manual. Manual No : 1796 Rev. : D Rev. Date : 11/2015

Series B9 and C9 Electronic Metering Pumps. Instruction Manual. Manual No : 1796 Rev. : D Rev. Date : 11/2015 Series B9 and C9 Electronic Metering Pumps Manual No : 1796 Rev. : D Rev. Date : 11/2015 sales@novatech-usa.com www.novatech-usa.com Tel: (866) 433-6682 Fax: (866) 433-6684 Tel: (281) 359-8538 Fax: (281)

More information

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set A board set has been developed that can be incorporated into an AIU for an RC2500 antenna controller. This board set is the basis of RC2500

More information

Uno International Ltd. 20 Belsize Avenue London NW3 4AU/England Co Reg No VAT No Stepper Control Board Manual ISS 8 June 2013

Uno International Ltd. 20 Belsize Avenue London NW3 4AU/England Co Reg No VAT No Stepper Control Board Manual ISS 8 June 2013 BOXER PUMPS 20 Belsize Avenue London NW3 4AU/England Co Reg No 4694961 VAT No. 858 3837 74 USA Clark Solutions 10 Brent Drive Hudson, MA 01749 Tel: 978-568-3400 sales@clarksol.com Stepper Control Board

More information

DCN0114 ATS Remote Annunciator Operation Manual. Automatic Transfer Switch Annunciator. Operation Manual. DCN0114 Rev 1

DCN0114 ATS Remote Annunciator Operation Manual. Automatic Transfer Switch Annunciator. Operation Manual. DCN0114 Rev 1 DCN0114 ATS Remote Annunciator Operation Manual Automatic Transfer Switch Annunciator Operation Manual 1 DCN0114 Rev 1 DOCUMENTATION This publication may have been revised or updated since this copy was

More information

PCL451. Manual Preset Indexer. User s Guide E Landon Drive, Anaheim, CA

PCL451. Manual Preset Indexer. User s Guide E Landon Drive, Anaheim, CA PCL451 Manual Preset Indexer User s Guide A N A H E I M A U T O M A T I O N 4985 E Landon Drive, Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V130 COM Modules: V100-17-CAN, V100-17-RS4/X, V100-17-ET2 This guide shows you how to install an additional communication module in a V130 controller. Instructions and technical specifications

More information

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL GENERAL DETAIL The AVC2 will control a stereo channel to a preset maximum output level allowing the maximum sound level of a system to be controlled. The AVC2

More information

RibEye Multi-Point Deflection Measurement System 3-Axis Version for the SIDIIs ATD Hardware Manual for Model January 2010

RibEye Multi-Point Deflection Measurement System 3-Axis Version for the SIDIIs ATD Hardware Manual for Model January 2010 USER S MANUAL RibEye Multi-Point Deflection Measurement System 3-Axis Version for the SIDIIs ATD Hardware Manual for Model 7715 15 January 2010 Boxboro Systems, LLC 978-257-2219 www.boxborosystems.com

More information

T4HD: Installation Supplement R8.1.13

T4HD: Installation Supplement R8.1.13 THD: Installation Supplement R8.. Smartscan Incorporated 08 Eight Mile Road Livonia MI 8 Tel: (8)77-900 Fax: (8) 77-7 Web: www.smartscaninc.com Smartscan Incorporated Livonia, Michigan THD The use of this

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

ES-362U PRESETTABLE MASTER TIMER

ES-362U PRESETTABLE MASTER TIMER 142 SIERRA ST., EL SEGUNDO, CA 90245 USA (310)322-2136 FAX (310)322-8127 www.ese-web.com ES-362U PRESETTABLE MASTER TIMER OPERATION AND MAINTENANCE MANUAL The ES-362U is a four digit, presettable 100 minute

More information

ASI Systems ML5740A Series

ASI Systems ML5740A Series ML5740A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5740A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information