Manual of Electrical Installation for Pressure Probes

Size: px
Start display at page:

Download "Manual of Electrical Installation for Pressure Probes"

Transcription

1 Manual of Electrical Installation for Pressure Probes Edition 0/0 Index. General precautions page. Transmitters with digital output page Standard installation page Electrical connections (series M / W / K / I / IJ) page 3. Transmitters with amplified analog output page 3 Standard installation page 3 Electrical connections (series TK / TPS / TS) page 3 Electrical connections (series TPF / TPH / TPS / TK) page 4 Electrical connections (series M / W / K / I) page 5 4. Transducers with nonamplified analog output page 8 Standard installation page 8 Electrical connections (series M / W / K / I) page 8 Electrical connections (series TPS) page 9 Electrical connections (series TPF / TPH) page 9 5. Protection for outdoor installations of analog sensors page 0 6. Standard reference page Manual of Electrical Installationfor Pressure Probes_00_ENG

2 . General Precautions The system must be used only in accordance with the required protection level. The sensor must be protected against accidental knocks and used in accordance with the instrument s ambient characteristics and performance levels. The sensors must be powered with nondistributed networks and always at lengths of less than 30 mt. In case of outdoor installations, follow the instructions in paragraph 5. Transducers: Series M / W / K / I / IJ Outputs: Nopen P404. Transmitters with digital output Installation notes The transducer must be grounded (normally through the machine body or equipment it is installed on). Use a shielded cable only. The braiding must be connected to the case of the 5pin connector. On instrument/pl side, we advise you connect the braiding without power supply (0V GN). To prevent interference, separate the power cables from the signal cables. Standard installation (recommended) raiding connected to connector case Machine Press Equipment M / W transducer PL / Instrument Rod / Pressure intake Ground able connector Shielded cable raiding connected to 0V GN of PL / Instrument Electrical connections Seriess M / W / K / I / IJ N US P404 digital output ontroller Power supply Power supply 5pin 3 an Output an H an L 4 5 M IN EN pin connector Manual of Electrical Installationfor Pressure Probes_00_ENG

3 3. Transmitters with amplified analog output Transducers: Series M / Series K / Series I / TK / TK / TPS / TPS / TS / TPF / TPH Outputs: 0...0V, 0...5V, 0,...0,V, V, 0,...5V, V, 4...0m, ecc... mv/v Installation notes The transducer must be grounded (normally through the machine body or equipment it is installed on). Use a shielded cable only. The braiding must be connected to the connector case. The braiding on instrument / PL side must be left floating. To prevent interference, separate the power cables from the signal cables Standard installation (recommended) raiding connected to connector case Machine Press Equipment Transducer PL / Instrument Rod / Pressure intake Ground able connector Floating braiding Shielded cable Electrical connections Series TK / TPS / TS urrent amplified output (mod. E) LO IGRM (urrent output) ONTROLLER MPL/ONV POWER SUPPLY SIGNL cod. V cod. P cod. F cod. E/M cod. Z 3 4 Yellow or lack LO RESISTNE RL RE OF POSSILE USE ase ase Shield ase POWER SUPPLY Voltage amplified output (mod. //M/N/P/Q/R) ONTROLLER POWER SUPPLY POWER SUPPLY OUTPUT cod. V cod. P cod. F cod. E/M cod. Z 3 White Green 4 Yellow or lack ase ase Shield 3 3 ase Manual of Electrical Installationfor Pressure Probes_00_ENG 3

4 Series TPF / TPS / TK / TPH Output amplified in current (mod. E) The cable sheathing is connected to the transducer body Output amplified in voltage (mod. //M/N/P/Q/R) The cable sheathing is connected to the transducer body LO IGRM (urrent output) Ω LO RESISTNE RL RE OF POSSILE USE Note: The igital utospan function is activated by means of the alibration contacts shown in the above diagram. For operation and complete functions, see the user manual (downloadable on POWER SUPPLY P 7 pole connector V 6 pole connector Z 4 pole male connector M x E EN Type M EN Type ind 3 4 Male connector Protection IP67 Male connector VPT006PT Protection IP66 4 pin Male connector serie 73 Protection IP67 4 Pin IN Type 4 Pin MicroIN Tipo industrial Shield F pole cable Yellow or lack Shielded cable x0,5 m. (output E) Shield F 4 pole cable Orange lue lack Shielded cable 4x0,5 m. (output E) Shield F 6 pole cable lack White Green lue Orange Shielded cable 6x0,5 m 4 Manual of Electrical Installationfor Pressure Probes_00_ENG

5 Series M / W / K urrent output (4...0m, wires) MGNETI UTOZERO EXTERNL UTOZERO 6pin 8pin 6pin 8pin ONTROLLER MPL./ONV. Power supply (0...30Vdc) (4...0m) alibration Shunt Power supply (0...30Vdc) (4...0m) utozero Shield drain wire is tied to connector via cable clamp G H G H Series I urrent output Shield drain wire is tied to connector via cable clamp RELY OUTPUT (68 pin connector) Shield drain wire is tied to connector via cable clamp LO IGRM 600 R (ohm) Vcc (Volt) The diagram shows the optimum ratio between load and power supply for transmitters with 4 0m output. For correct function, use a combination of load resistance and voltage that falls within the two lines in the graph above. Manual of Electrical Installationfor Pressure Probes_00_ENG 5

6 Series M W K VOLTGE OUTPUT (M, N,, ) Supply 5..30Vdc MGNETI UTOZERO 6pin Shield drain wire is tied to connector via cable clamp EXTERNL UTOZERO 6pin ONTROLLER Supply Supply Siupply Supply MPLIF. Segnale alibration Shunt utozero Voltage output (H, L) Power supply 5..5Vdc (*) (*) The Pin of the connector must be connected to the common of the ± 5Vdc supply 8pin connector E F G H onnector P0688 (SR) onnect the cable sheathing to the side of the instrument Ral No connection E Power supply S E Power supply S Magnetic utozero version = Excitation (white) = (red) = Excitation (green) = (black) E = Ral (blue) F = Ral (brown) G = no connection H = no connection External utozero version = Excitation (white) = (red) = Excitation (green) = (black) E = utozero (blue) F = utozero (brown) G = no connection H = no connection Series I VOLTGE OUTPUT (M, N,, ) Supply 5..30Vdc 6 Manual of Electrical Installationfor Pressure Probes_00_ENG

7 Series I7 VOLTGE OUTPUT Shield drain wire is tied to connector via cable clamp RELY OUTPUT (68 pin connector) 6pin connector VPT07R06PT (PT006P) 8pin connector P0E8P endix 8 pin connector (inder) M6 IN/EN4536 ( ) Manual of Electrical Installationfor Pressure Probes_00_ENG 7

8 4. Transducers with nonamplified analog output Transducers: Series M / Series W / Series K / Series I / TPS / TPF / TPH Output: mv/v Installation notes The transducer must be grounded (normally through the machine body or equipment it is installed on). Use a shielded cable only. The braiding on connector side must be left floating. The braiding on instrument / PL side must be connected to the power supply GN. To prevent interference, separate the power cables from the signal cables Standard installation (recommended) Floating braiding (not connected) Machine Press Equipment PL / Instrument Rod / Pressure intake Ground able connector Shielded cable Electrical connections Series M / W / K 6pin 8pin mv/v output Supply Supply alibration Shunt Series I Ral G H mv/v OUTPUT Shield drain wire is tied to connector via cable clamp 6pin connector VPT07R06PT (PT006P) 8pin connector P0E8P endix 8 Manual of Electrical Installationfor Pressure Probes_00_ENG

9 Series TPS / TPF / TPH mv/v output P 7 pole connector V 6 pole connector F 6 pole cable Shield Male connector Protection IP67 Male connector VPT006PT Protection IP66 Shielded cable 6x0,5 m lack White Green lue Orange Z 4 pole male connector M x E EN Type M EN Type ind pin Male connector serie 73 Protection IP67 4 Pin IN Type 4 Pin MicroIN Tipo industrial Manual of Electrical Installationfor Pressure Probes_00_ENG 9

10 5. Protection for outdoor installations of analog sensors Pressure / nalog Melt current output L signals if any do not require protection J J PL side 4Vdc 3 Transducer side 4Vdc 70S50K0 70S50K0 PL ground J J machine ground PL side IN Transducer side OUT 70S50K0 J PL side Ground Pressure / nalog Melt voltage output L signals if any do not require protection J J PL side 4Vdc Transducer side 4Vdc 70S50K0 70S50K0 PL ground J J machine ground PL side IN 3 Transducer side OUT 70S50K0 J J PL side GN 4 Transducer side GN 70S50K0 J PL side Ground 0 Manual of Electrical Installationfor Pressure Probes_00_ENG

11 6. Standard reference Gefran products, described in this manual, are compliant to the European irective 004/08/E. They are tested according to the standard EN 636 Electrical equipment for measurement, control and laboratory use EM requirements, Part general requirements and EN 6363 Electrical equipment for measurement, control and laboratory use EM requirements, Part 3: Particular requirements Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning. Electromagnetic ompatibility (EM) requirements are classified in two types: Emission requirements, Immunity requirements Emission requirements For class equipment the limits, the measuring methods and the provisions given in ISPR, EN and EN apply. Equipment classification and choice of respective limits shall be determined after taking into account the intended environment and emission requirement in the areas of use Immunity requirements The immunity test requirements are given in table. The tests shall be conducted in accordance with the basic standards. The tests shall be carried out one at time. Table Immunity test requirements for equipment intended for use in industrial locations Port Phenomenon asic Test value Performance Performance standard criteria criteria requested applied by Gefran Enclosure Electrostatic discharge (ES) EN kv / 8 kv contact/air EM field EN V/m (80 MHz to GHz) 3 V/m (,4 GHz to GHz) V/m (,0 GHz to,7 GHz) Rated power frequency EN /m (@ 400 /m) magnetic field Power supply g) urst EN kv (5/50 ns, 5 khz) Surge EN kv a) / kv b) onducted RF EN V (50 khz to 80 MHz) (@ 0V) I/O signal/control urst EN kv (5/50 ns, 5 khz) d) (including functional Surge EN kv b), c) earth lines) onducted RF EN V (0 khz to 80 MHz) (@ 0V) a) Line to line b) Line to ground c) Only in the case of longdistance lines d) Only in the case of lines > 3 m g) connections between parts of equipment/system which are not connected to a d.c. distribution network are treated as I/O signal/ control ports Performance criterion uring testing, normal performance within the specification limits. Example If electronic equipment is required to work with high reliability, the EUT shall operate without any apparent degradation from the manufacturer s specification. Performance criterion uring testing, temporary degradation, or loss of function or performance which is selfrecovering. Example uring testing, an analogue function value may deviate. fter the test, the deviation vanishes. Performance criterion uring testing, temporary degradation, or loss of function or performance which requires operator intervention or system reset occurs. Example In the case of an interruption in the mains longer than the specified buffer time, the power supply unit of the equipment is switched off. The switchon may be automatic or carried out by the operator. opy of the conformity declaration is available for download on the Gefran web site Sensorik Messtechnik 800 Graz, Riesstraße 46 Tel.: , Fax: Handelsgesellschaft m.b.h. Manual of Electrical Installationfor Pressure Probes_00_ENG

Manual of Electrical Installation for Pressure Probes

Manual of Electrical Installation for Pressure Probes Manual of Electrical Installation for Pressure Probes ode 85306 Edition 07/07 Index. General precautions page. Transmitters with digital output page Standard installation page Electrical connections (series

More information

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series GEFRAN SAFETY GUARANTEE Code 8594A Edition 2/204 Contents. General precautions pag 2 2. Transmitters with amplified analog output

More information

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1 Characteristics pressure sensor XMLK - 0..6bar - G 1/4A - 4..20mA - DIN - set of 1 Complementary Pressure setting range Maximum permissible accidental pressure Destruction pressure Materials in contact

More information

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12 Characteristics Pressure sensors XMLR 400bar - G 1/4-24VDC - 4..20 ma - PNP - M12 Complementary Current consumption Electrical connection Type of output signal Analogue output function Discrete output

More information

XXA18P1AM12 Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12

XXA18P1AM12 Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12 Characteristics Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12 Complementary Enclosure material Front material Supply voltage limits Function available [Sa] assured operating

More information

TM3TI8T module TM3-8 inputs temperature

TM3TI8T module TM3-8 inputs temperature Characteristics module TM3-8 inputs temperature Main Range of product Product or component type Range compatibility Analogue input number 8 Analogue input type Complementary Analogue input resolution Input

More information

TM3TI4 module TM3-4 inputs temperature

TM3TI4 module TM3-4 inputs temperature Characteristics module TM3-4 inputs temperature Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible

More information

MELT PRESSURE TRANSMITTERS KE SERIES PERFORMANCE LEVEL c

MELT PRESSURE TRANSMITTERS KE SERIES PERFORMANCE LEVEL c MELT PRESSURE TRANSMITTERS KE SERIES PERFORMANE LEVEL c Output 4...20mA The KE Performance Level c series of Gefran are pressure transmitters for using in high temperature environment. The main characteristic

More information

TM3AI4 module TM3-4 analog inputs

TM3AI4 module TM3-4 analog inputs Characteristics module TM3-4 analog inputs Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible

More information

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Characteristics Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Main Range of product Product or component type Complementary Supply [Us] rated supply voltage Immunity to microbreaks

More information

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM3TM3 module TM3-2 temperature inputs and 1 analog output Characteristics module TM3-2 temperature inputs and 1 analog output Main Range of product Product or component type Range compatibility Analogue input number 2 Analogue input type Analogue output number

More information

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/418NPT V - M12 - set 1 Characteristics pressure transmitter - XMLP - 200psi - 1/4"18NPT - 0..10V - M12 - set 1 Complementary Pressure setting range Maximum permissible accidental pressure Destruction pressure Materials in contact

More information

mv/v Output IMPACT MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS

mv/v Output IMPACT MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS IMPACT MELT PRESSURE TRANSMITTERS I3 SERIES mv/v Output The IMPACT series of Gefran, are pressure transmitters, without transmission fluid, for using in High temperature environment (350 C). Medium pressure

More information

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS MELT PRESSURE TRANSMITTERS I3 SERIES mv/v Output D The IMPACT series of Gefran, are pressure transmitters, without transmission fluid, for using in High temperature environment (350 C). Medium pressure

More information

MELT PRESSURE TRANSMITTERS IE SERIES WITH CURRENT OUTPUT AND PLc VERSION

MELT PRESSURE TRANSMITTERS IE SERIES WITH CURRENT OUTPUT AND PLc VERSION MELT PRESSURE TRANSMITTERS IE SERIES WITH CURRENT OUTPUT AND PLc VERSION 4-20mA Output The IMPACT series of Gefran, are pressure transmitters, without transmission fluid, for using in High temperature

More information

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB Strain gauge Measuring Amplifier GSV-A8 Instruction manual GSV-A8, GSV-A8USB, GSV-A6USB GSV-A8USB SubD5 (front side) GSV-A8USB M2 (front side) GSV-A6USB (rear side) GSV-A8USB K6D (front side) Version:

More information

PRESSURE TRANSMITTER

PRESSURE TRANSMITTER KS PRESSURE TRANSMITTER GEFRAN SAFETY GUARANTEE Main Features Ranges: from 1 to 1000 bar Nominal Output Signal: 4...20mA (2 wires) 0...10Vdc / 0.1...5.1Vdc / 0.1...10.1Vdc / 0...5Vdc / 1...5Vdc / 1...6Vdc

More information

Voltage Output IMPACT MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS

Voltage Output IMPACT MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS IMPACT MELT PRESSURE TRANSMITTERS IN SERIES Voltage Output The IMPACT series of Gefran, are pressure transmitters, without transmission fluid, for using in High temperature environment (350 C). Medium

More information

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Product data sheet Characteristics HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Main Range of product Product or component type Device presentation Complementary Supply

More information

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing The TSR10 is a 10 kw, 3-phase input voltage 360-440 VAC power supply with an adjustable DC output voltage between 0.5 V and 50 V and output current between 0.5 A and 200 A. The power supply has been designed

More information

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO Characteristics compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO Main Range of product Product or component type Complementary Enclosure material Colour Input/Output number

More information

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)

More information

MELT PRESSURE TRANSMITTERS KE SERIES PERFORMANCE LEVEL c

MELT PRESSURE TRANSMITTERS KE SERIES PERFORMANCE LEVEL c MELT PRESSURE TRANSMITTERS KE SERIES PERFORMANE LEVEL c Output 4...20mA The KE Performance Level c series of Gefran are pressure transmitters for using in high temperature environment. The main characteristic

More information

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box Product datasheet Characteristics TM7BDM8B Main Range of product Product or component type Range compatibility Enclosure material Bus type System Voltage Input/output number 8 Input/output number of splitter

More information

TM3TI4 module TM3-4 inputs temperature

TM3TI4 module TM3-4 inputs temperature Characteristics module TM3-4 inputs temperature Complementary Analogue input resolution Permissible continuous overload Input impedance LSB value Conversion time Sampling duration Main Range of product

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector Characteristics expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus type [Ue] rated operational

More information

IK4A (with ONDA technology)

IK4A (with ONDA technology) IK4A (with ONDA technology) CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (ANALOG OUTPUT) Main characteristics ONDA technology Optimized mechanical structure Strokes from 50 to 4000 Wide range

More information

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Characteristics 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Main Range of product Product or component type Display size Display type Pixel resolution Touch panel Offer Sustainability

More information

Voltage Output MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS

Voltage Output MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS MELT PRESSURE TRANSMITTERS IN SERIES Voltage Output The IMPACT series of Gefran, are pressure transmitters, without transmission fluid, for using in High temperature environment (350 C). Medium pressure

More information

TM221CE40R controller M IO relay Ethernet

TM221CE40R controller M IO relay Ethernet Characteristics controller M221 40 IO relay Ethernet Main Range of product Product or component type [Us] rated supply voltage Jan 6, 2019 Modicon M221 Logic controller 100...240 V AC Discrete input number

More information

GSV-3USBx2 3,5mV/V 4,2V

GSV-3USBx2 3,5mV/V 4,2V x2 3,5mV/V 4,2V Highlights Powered via USB port Sampling rate 10 khz Data rate 1...1000 Hz straingage quarter, half, full bridges Built-in bridge supplement 350 Ohm Optionally also for displacement transducers

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

PDD-300 pulsed diode driver

PDD-300 pulsed diode driver rev 1.08 / 2019 02 13 PDD-300 pulsed diode driver User manual Warning! This equipment may be dangerous. Please read user manual before starting operations. Important note. Please measure output with adequate

More information

TM221CE24T controller M IO transistor PNP Ethernet

TM221CE24T controller M IO transistor PNP Ethernet Characteristics controller M221 24 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type

More information

HMISCU6B5. Main. 60 right 40 top 60 bottom

HMISCU6B5. Main. 60 right 40 top 60 bottom Product datasheet Characteristics HMISCU6B5 Main Range of product Product or component type Display size Display type Touch panel Device presentation Magelis SCU Small touch HMI controller 3.5 inch With

More information

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS MELT PRESSURE TRANSMITTERS I3 SERIES mv/v Output D The IMPACT series of Gefran, are pressure transmitters, without transmission fluid, for using in High temperature environment (350 C). Medium pressure

More information

XPSMCMDO Digital output pairs expansion modules with screw term

XPSMCMDO Digital output pairs expansion modules with screw term Characteristics 2 Digital output pairs expansion modules with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs

More information

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Linearized RTD Input 5B34 FEATURES Amplifies, Protects, Filters, and Isolates Analog Input. Linearize a wide variety of 2 & 3 wire RTDs. (True 4-wire RTD measurements are provided by the 5B35).

More information

XGCS491B201 Standalone panel smart antenna

XGCS491B201 Standalone panel smart antenna Characteristics Standalone panel smart antenna Complementary Operating mode Type of output signal Discrete output function Discrete output type Switching capacity in ma Associated tag type Supply voltage

More information

TM221M16TG controller M IO transistor PNP spring

TM221M16TG controller M IO transistor PNP spring Characteristics controller M221 16 IO transistor PNP spring Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type Discrete

More information

TM221CE24R controller M IO relay Ethernet

TM221CE24R controller M IO relay Ethernet Product data sheet Characteristics TM221CE24R controller M221 24 IO relay Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Network frequency Inrush

More information

XPSMCMDI Input expansion module with screw term

XPSMCMDI Input expansion module with screw term Characteristics 16 Input expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs Number of outputs

More information

TM221M32TK controller M IO transistor PNP

TM221M32TK controller M IO transistor PNP Characteristics controller M221 32 IO transistor PNP Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type Discrete

More information

TM221CE40R controller M IO relay Ethernet

TM221CE40R controller M IO relay Ethernet Product datasheet Characteristics TM221CE40R controller M221 40 IO relay Ethernet Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete

More information

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box Product datasheet Characteristics TM7BDI16B Main Range of product Product or component type Range compatibility Enclosure material Bus type System Voltage Input/output number 16 Input/output number of

More information

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Voltage or Current Input 7B41 FEATURES Interfaces, amplifies and filters unipolar and bipolar voltage inputs. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V. All 7B41

More information

TM221CE40T controller M IO transistor PNP Ethernet

TM221CE40T controller M IO transistor PNP Ethernet Product data sheet Characteristics TM221CE40T controller M221 40 IO transistor PNP Ethernet Complementary Main Discrete I/O number 40 Number of I/O expansion module Supply voltage limits Inrush current

More information

Flexible temperature transmitter and sensor

Flexible temperature transmitter and sensor / processing unit without display senso a mperature senso TT/TC series TT/TC ser Flexible temperature transmitter and sensor The of the TT/TC series detect temperature with a Pt100 4-wire probe. Available

More information

TM221ME16T controller M IO transistor PNP Ethernet

TM221ME16T controller M IO transistor PNP Ethernet Characteristics controller M221 16 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type

More information

TM221CE24T. Main. Discrete output logic. Discrete input current. <= 7 relay output

TM221CE24T. Main. Discrete output logic. Discrete input current. <= 7 relay output Product datasheet Characteristics TM221CE24T Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type Discrete output number

More information

GSV-1A4 M12/2 M12/2. Highlights

GSV-1A4 M12/2 M12/2. Highlights GSV-1A4 M12/2 M12/2 Highlights Input sensitivity: 2mV/V; 4mV/V, 2 mv/v, 1mV/V, 0.5mV/V configurable via jumpers Output signals ±10V AND 12mA+-8mA on 15 pin Sub-D Integrated half and quarter bridge completion

More information

DENISON HYDRAULICS Jupiter Power Supply Accessory Series S

DENISON HYDRAULICS Jupiter Power Supply Accessory Series S DENISON HYDRAULICS Jupiter Power Supply Accessory Series S20-11715-0 Jupiter Power Supply Accessory S20-11715-0 Jupiter Power Supply Accessory w/ Driver Card S20-11712 Publ. 9-AM686 E-Mail: denison@denisonhydraulics.com

More information

U10M. Data Sheet. Force transducers. Special features. Mounting dimensions of the connection variants in mm [inch] B en

U10M. Data Sheet. Force transducers. Special features. Mounting dimensions of the connection variants in mm [inch] B en U10M Force transducers Data Sheet Special features - Tensile/compressive force transducer - For dynamic and static applications - High endurance at high vibration bandwidths - Electronic bending moment

More information

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A... Electronics & Software MiniAmp Type 5030A... Miniature Charge Amplifier The MiniAmp Type 5030A is a single channel, industrial charge amplifier, which converts the charge signal from piezoelectric sensors

More information

TM221ME32TK controller M IO transistor PNP Ethernet

TM221ME32TK controller M IO transistor PNP Ethernet Product data sheet Characteristics TM221ME32TK controller M221 32 IO transistor PNP Ethernet Complementary Main Discrete I/O number 32 Number of I/O expansion module Supply voltage limits Inrush current

More information

XGCS RFID compact smart antenna MHz - flat form 40x40x15 - M12 - cable 0.2m

XGCS RFID compact smart antenna MHz - flat form 40x40x15 - M12 - cable 0.2m Characteristics RFID compact smart antenna - 13.56MHz - flat form 40x40x15 - M12 - cable 0.2m Complementary Communication port protocol Communication port support Associated tag type Supply voltage limits

More information

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs Characteristics 3 5 color touch controller panel - Dig 16 inputs/10 outputs Main Range of product Product or component type Display size Display type Pixel resolution Touch panel Offer Sustainability Sustainable

More information

RK-5 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED CONNECTION. Main features

RK-5 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED CONNECTION. Main features RK-5 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED CONNECTION (ANALOG OUTPUT) Main features Absolute transducer Stroke: 50 to 2500mm Direct analog output (RK-5 N/K/E) Inverse analog

More information

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs Characteristics 5 7 color touch controller panel - Dig 16 inputs/10 outputs Main Range of product Product or component type Display size Display type Pixel resolution Touch panel Complementary Backlight

More information

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E... Operating Instructions for Low Volume Rotating Vane Flow Meter Model: DPL-1P... DPL-1V... DPL-1E... 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating

More information

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term Characteristics Modbus TCPIP diagnostic expansion module with screw term Main Range of product Product or component type Device short name [Us] rated supply voltage Complementary Power dissipation in W

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is

More information

GEN series G070A. Data sheet. Torque/RPM adapter. Special features

GEN series G070A. Data sheet. Torque/RPM adapter. Special features GEN series G070A Torque/RPM adapter Data sheet Special features - Connect up to two torque transducers - Connect to T12/T40B using standard cables - RS422 differential input signals for highest immunity

More information

Technical specifications

Technical specifications Technical specifications General information Operating temperature -25 to 60 C Storage temperature -40 to 70 C Enclosure type Panel installation (DIN IEC 61554) Enclosure fixing Screw-type clamping technology

More information

TM3DI16 module TM3-16 inputs

TM3DI16 module TM3-16 inputs Characteristics module TM3-16 inputs Main Range of product Product or component type Range compatibility Jun 30, 2018 Modicon TM3 Discrete input module Modicon M241 Modicon M251 Modicon M221 Discrete input

More information

XPSMCMMX inputs 2 output pairs expansion module with screw term

XPSMCMMX inputs 2 output pairs expansion module with screw term Characteristics 8 inputs 2 output pairs expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs

More information

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector Characteristics expansion block - TM7 - IP67-16 DI/DO - 24V DC - 0.5 A - M12 connector Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 753.00 USD Main Range of

More information

HMISCU8B5 5 7 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

HMISCU8B5 5 7 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Characteristics 5 7 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Product availability : Stock - Normally stocked in distribution facility Price* : 1,359.56 USD Main Range of product

More information

REPORT OF ELECTROMAGNETIC SUSCEPTIBILITY TESTS PERFORMED ON GPS ANTENNA PART NUMBER 42G1215A-XT-1-N PREPARED FOR:

REPORT OF ELECTROMAGNETIC SUSCEPTIBILITY TESTS PERFORMED ON GPS ANTENNA PART NUMBER 42G1215A-XT-1-N PREPARED FOR: Page 1 of 64 National 1536 East Valencia Drive Technical Fullerton, California 92831 Systems Tel: 714-879-6110 Fax: 714-879-6117 www.ntscorp.com REPORT OF ELECTROMAGNETIC SUSCEPTIBILITY TESTS PERFORMED

More information

TM241CEC24R controller M IO relay Ethernet CAN master

TM241CEC24R controller M IO relay Ethernet CAN master Characteristics controller M241 24 IO relay Ethernet CAN master Main Range of product Product or component type [Us] rated supply voltage Nov 28, 2017 Modicon M241 Logic controller 100...240 V AC Discrete

More information

TM221M16R controller M IO relay

TM221M16R controller M IO relay Product data sheet Characteristics TM221M16R controller M221 16 IO relay Complementary Main Discrete I/O number 16 Number of I/O expansion module Supply voltage limits Inrush current Power consumption

More information

TM221ME16T controller M IO transistor PNP Ethernet

TM221ME16T controller M IO transistor PNP Ethernet Product datasheet Characteristics TM221ME16T controller M221 16 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage Modicon M221 Logic controller 24 V DC

More information

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Level sensor Stainless steel version Model RLT-1000, for industrial applications Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring

More information

REPORT OF ELECTROMAGNETIC SUSCEPTIBILITY TESTS PERFORMED ON GPS ANTENNA PART NUMBER 42G1215A-XT-1-N PREPARED FOR:

REPORT OF ELECTROMAGNETIC SUSCEPTIBILITY TESTS PERFORMED ON GPS ANTENNA PART NUMBER 42G1215A-XT-1-N PREPARED FOR: Page 1 of 40 National 1536 East Valencia Drive Technical Fullerton, California 92831 Systems Tel: 714-879-6110 Fax: 714-879-6117 www.ntscorp.com REPORT OF ELECTROMAGNETIC SUSCEPTIBILITY TESTS PERFORMED

More information

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW Isolated Current Output 5B39 FEATURES Converts a High-level analog input voltage into a floating proportional output current. Output current of 4 to 20 ma or 0 to 20 ma across loads from 0Ω to 750Ω. High

More information

AccuStar Electronic Clinometer

AccuStar Electronic Clinometer AccuStar Electronic Clinometer Single Axis ± 60 Range The AccuStar Electronic Clinometer is an extremely accurate angle measurement device. This compact and rugged sensor is ideal where space is critical

More information

Measuring Amplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges

Measuring Amplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges +49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Measuring mplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges Features M Bridge sensitivity

More information

TMT470L Temperature Transmitter

TMT470L Temperature Transmitter Technical information TMT470L Temperature Transmitter OEM components for compact thermometer/cable transmitter. 2/3 or 4-wire Pt100 can be connected. 4 to 20 ma transmitter, programmable via PC. Application

More information

RT300 Series Crane & Hoist Joystick. RunnTech. Potentiometer: ±32, Hall sensor: ±20

RT300 Series Crane & Hoist Joystick. RunnTech. Potentiometer: ±32, Hall sensor: ±20 Electronics (Changzhou) Corp. RT00 Series Crane & Hoist Joystick RT00 Series Crane & Hoist Joystick Product Features Single axis or dual axis control; Pure silver contacts to ensure durable; Spring return

More information

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES INSTRUCTION MANUAL KEPCO An ISO 9001 Company. 300 WATT, PFC, OPEN FRAME POWER SUPPLIES RMW 300W SERIES I INTRODUCTION SCOPE OF MANUAL. This instruction manual covers the installation and operation of the

More information

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O Product datasheet Characteristics RM22LA32MR Level control relay RM22-L - 24..240 V AC/DC - 2 C/O Main Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay

More information

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 Manual PCD3.C90 Revision History Date Modification Asked by: Version 14.09.09 E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 22.09.09 Added E/A Bus Connector PCD3.K116 Müller.R 1.2 06.01.10

More information

Installation & Configuration manual. InduBox GSM IV

Installation & Configuration manual. InduBox GSM IV Installation & Configuration manual InduBox GSM IV 2008 / 02 / 19 2 ! CAUTION! ELECTRIC SHOCK HAZARD IF COVER REMOVED SERVICE BY QUALIFIED PERSONEL ONLY Document History Date Version Auteur 02/10/2006

More information

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2. Product datasheet Characteristics TM241CEC24T Main Range of product Product or component type [Us] rated supply voltage Discrete input number Discrete output type Discrete output number Discrete output

More information

Installation Requirements for Conformance to Standards

Installation Requirements for Conformance to Standards User Manual for Industrial Control Products Installation Requirements for Conformance to Standards Fourth Edition 26 September 2000 MAN0005-04 MAN0005-04 26 SEP 2000 PAGE 3 PREFACE This manual explains

More information

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Process Current Input 7B32 FEATURES Interfaces, amplifies and filters a process-current input. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V, linear with temperature.

More information

EAM 58 B / C - 63 A / D / E BIT PARALLEL - SSI

EAM 58 B / C - 63 A / D / E BIT PARALLEL - SSI EAM 58 B / C - 63 A / D / E BIT PARALLEL - SSI SOLID SHAFT MULTITURN ABSOLUTE ENCODER MAIN FEATURES Industry standard multiturn absolute encoder for factory automation applications. Optical sensor technology

More information

KOBOLD TDA Series Digital Temperature Transmitter

KOBOLD TDA Series Digital Temperature Transmitter KOBOLD TDA Series Digital Temperature Transmitter TDA-15 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com

More information

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES Interfaces, amplifies, protects& filters wide-bandwidth (h0 khz) single-channel analog voltage inputs. Module provides simultaneous precision voltage

More information

Number of optical axis

Number of optical axis Ultra-flat multi-beam sensor for elevators F3E Ultra-flat 9 mm shape for easy design-in in elevator constructions Highest ambient light immunity (200,000 lux) for installations with direct sunlight exposition

More information

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient Features Regulated Converter Description Household, medically and ITE certified Class II installations (without FG) IP68 waterproof encapsulation Long life components, rugged module Energy Efficiency Level

More information

TM221ME16RG. Main. Discrete output number. Discrete input current

TM221ME16RG. Main. Discrete output number. Discrete input current Product datasheet Characteristics TM221ME16RG Main Range of product Product or component type [Us] rated supply voltage Modicon M221 Logic controller 24 V DC Discrete input number 8 discrete input conforming

More information

Installation Instructions

Installation Instructions Installation Instructions (Catalog Number 1771-IR Series D) Use this document as a guide when installing the 1771-IR/D input module. The RTD input module is sensitive to electrostatic discharge. ATTENTION:

More information

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/ DC - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type Time

More information

MODEL ITMA - INTELLIGENT THERMOCOUPLE MODULE WITH ANALOG OUTPUT

MODEL ITMA - INTELLIGENT THERMOCOUPLE MODULE WITH ANALOG OUTPUT Bulletin No. ITMA-D Drawing No. LP082 Released 1/07 Tel +1 (717) 767-6511 Fax +1 (717) 764-089 www.redlion.net MODEL ITMA - INTELLIGENT THERMOCOUPLE MODULE WITH ANALOG OUTPUT USER PROGRAMMABLE INPUT (Thermocouple

More information

RT02 Series Robust Industrial Joystick. RunnTech

RT02 Series Robust Industrial Joystick. RunnTech Electronics (Changzhou) Corp. RT0 Series Robust Industrial Joystick RT0 Series Robust Industrial Joystick Product Features Potentiometer sensor or Hall sensor; Single axis, dual axis or axis control; Resistant

More information

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Voltage Input 7B31 FEATURES Interfaces, amplifies, and filters unipolar and bipolar voltage inputs. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V, linear with temperature.

More information

TM3DI16G module TM3-16 inputs spring

TM3DI16G module TM3-16 inputs spring Characteristics module TM3-16 inputs spring Main Range of product Product or component type Range compatibility Modicon TM3 Discrete input module Modicon M221 Modicon M241 Modicon M251 Discrete input number

More information

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN Highlights & Features Full corrosion resistant Aluminium chassis Suitable for 24V system up to 40A Built-in diagnostic monitoring for DC OK, Discharge and Battery Fail by relay contacts LED indicator for

More information

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment TR No. 176002 1.1.EDITION April 1st, 2015 Nippon Telegraph and Telephone Corporation Introduction This document describes

More information