1. DB-9 interface pins Definition

Size: px
Start display at page:

Download "1. DB-9 interface pins Definition"

Transcription

1 1

2 I. unction description II. Dry contact card is UPS options, which is used to provide UPS internal status to the outside or control peripheral device according to UPS status in the form of dry contact. Card-insert dry contact adopts golden-finger interface, you can insert it into SNMP slot of the working UPS directly. Introduction of dry contact interface It mainly introduces DB9 interface pins definition and function of card-insert dry contact. 1. DB-9 interface pins Definition DB-9 pin No. Function description Input/output 1 UPS Failure output 2 UPS Summary Alarm output 3 GND 4 Remote Shutdown input 5 Common Source 6 Bypass Active output 7 Battery Low output 8 UPS ON output 9 Utility Failure output 2

3 2. DB-9 interface pins instruction Phenomena Function Description Reason PIN1, PIN5 ON UPS Failure UPS internal failure PIN2, PIN5 ON UPS Summary Alarm 1. UPS is on battery mode. 2. Battery low. 3. UPS internal failure. PIN3 PIN4 PIN5 GND Remote Shutdown Common source The outside input remote shutdown signal. PIN6, PIN5 ON Bypass Active Bypass powers the load. PIN6, PIN5 OFF UPS ON Inverter powers the load PIN7, PIN5 ON Battery Low Battery Low PIN8, PIN5 ON UPS ON Inverter powers the load PIN8, PIN5 OFF Bypass Active Bypass powers the load PIN9, PIN5 ON Utility Failure Utility failure 3. DB-9 internal interface Route 3

4 4. DB-9 interface electric parameter Diode Relay Parameter Symbol MAX UNIT Reverse Voltage VR 6 V Forward current IF 80 Ma Peak Forward current IF(peak) 1 A DC Voltage VDC 28 V DC Current IDC 7.0 A AC Voltage AC Current VAC IAC V V A A 5. Application instruction of dry contact card Peripheral monitoring device provides regular power to common terminal. Take the shown circuit for example, every signal terminal connects to relevant indicator and remote shutdown key, then it can achieve monitoring the UPS remotely. 4

5 6. Pins definition of connecting terminal on the board Terminal No. Terminal function Terminal No. Terminal function 1 UPS failure NC(normally closed) 9 Invert on NC 2 UPS failure NO(normally open) 10 Invert on NO 3 Bypass status NC 11 Utility failure NC 4 Bypass status NO 12 Utility failure NO 5 UPS alarm NC 13 Operation indication NC 6 UPS alarm NO 14 Operation indication NO 7 Battery low NC 15 Common source 8 Battery low NO 16 Common source For the function of connecting terminal on the board, you can refer to DB9 interface pins instruction. The wire connecting is also similar to DB9. It also provides normally open contact (even terminal pin) besides the normally closed contact (odd terminal pin). For function definition of connecting terminal, you can also get relevant information from the silk-print on the rear of the card. III. Product appearance 5

6 IV. Range of use It applies to high frequency on-line UPS with SNMP slot. V. Application field 1. IBM server, PC machine, work station and other device application. 2. Industry device automatic control and communication application. 3. Dry contact card only provides interface (dry contact), users make application software themselves. VI. Installation 1. Open the cover plate of SNMP SLOT on the rear panel of UPS. 2. Insert dry contact card directly along the gap of SNMP SLOT. 3. Insert dry contact card until the metal plate of DB9 interface clings closely to surface of UPS rear panel. It indicates the card insertion is OK. Then use the screw lock and fasten the dry contact card. 6

7 4. Connect with monitoring device by connecting wire of dry contact card. The monitoring device will display and control UPS operating status, to achieve remote monitoring of UPS operation. 7

8 VII. Trouble diagnosis and elimination When the UPS is working, install the dry contact card correctly, after the card getting the power, you will get operating status of the card by the status of operation indication terminal. If the card gets the power, but the communication connection with UPS is cut off, there will be tick 1 time per second in the card. If connect the indication circuit to pin 13/14 of the terminal block, you will get a 0.5Hz on-off signal. If the card operates all right, pin 14 of the terminal block will be connected to common terminal, and pin 13 is off. After confirmed that the UPS is working, and the card is installed correctly, if continuous once per second tick is heard in the card or the status of operation indication terminal is wrong, please contact the agency. 8

Connecting a Cisco Output Module

Connecting a Cisco Output Module CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which

More information

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit MBP68300 SERIES AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters Modular Construction AC-distribution 3pcs of MCBs Manual bypass switch BPU69000 Dual External static switch

More information

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range MSR 2400W Multi purpose Power System for Telecom and Industrial Applications 2400 W modular system All voltages available 0 144VDC per module U and I adjustable from 0 to max value Hot-swap plug-in modules

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER On-line UPS-system according to DIN EN 62040-3 (VFI-SS-111) with sinus soidal output voltage in each operation mode, RS232 interface and Shutdown-Software for Windows NT/2000/XP/2003/Vista, Novell and

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Quick Start Guide. SEB-710 I/O Expansion board. Introduction SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay

More information

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications MSR 2400R Rugged Power System for Military and Heavy Duty Applications 2400 W modular power system Power supply or battery charging systems Parallel n+1 connection, up to 90A Series connection, up to 360VDC

More information

DIGITAL PROCESS CONTROLLER

DIGITAL PROCESS CONTROLLER 1 DPC 965 M R1 R2 R3 R4 TX RX PROG [OPERATOR S MANUAL] 2 Contents Section 1 specification.page 4 Section 2 system Programming Page 4 to 11 Section 3 Precautions..Page 11 Section 4 Connection Diagram.Page

More information

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance. INTRODUCTION Thank you for choosing our product. The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance. This manual

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer)

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer) Version: 2016-08-18 Multi-IQ Firmware: (Serial Number / Seriennummer) RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable User manual MANUAL ENGLISH... 2 GENERAL PROPERTIES:... 2

More information

Power supplies CP-E, CP-S and CP-C range NEW! CP-E Range

Power supplies CP-E, CP-S and CP-C range NEW! CP-E Range Power supplies CP-E, CP-S and CP-C range CP-E Range The new CP-E range power supplies M odern switch mode AC to DC power supplies are a vital component in most information gathering systems, energy management,

More information

Installation Instructions (KF-2000)

Installation Instructions (KF-2000) VERSION 2005. 10 Installation Instructions (KF-2000) Keico Hightech, Inc. Installation Instructions KF-2000 Keico Hightech Ace Twin Tower I 12 th FL 212-1, Guro-Dong, Guro-Gu Phone +82-2-853-9000 Fax +82-2-830-7809

More information

OPERATING INSTRUCTIONS. Programmable relay card

OPERATING INSTRUCTIONS. Programmable relay card OPERATING INSTRUCTIONS Programmable relay card EN 3 CONTENTS Information about these operation instructions... 4 General Information... 5 1.1 specification... 5 1.2 detailed view... 7 1.3 Contacts ex

More information

The accessory described in this manual is a high quality product that has been carefully designed and manufactured to guarantee optimal performance.

The accessory described in this manual is a high quality product that has been carefully designed and manufactured to guarantee optimal performance. INTRODUCTION Thank you for choosing our product. The accessory described in this manual is a high quality product that has been carefully designed and manufactured to guarantee optimal performance. This

More information

Connecting a Cisco Input Module

Connecting a Cisco Input Module CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each

More information

Product Specifications

Product Specifications Product Specifications Models: USC-10001, USC-10002 USC-20001, USC-20002 USC-30001, USC-30002 Guide Specification for UniStar C Series Rack/Universal 1, 2, 3Kva Single-Phase, On-Line Double Conversoin

More information

Quick Guide. Extra Communication Card

Quick Guide. Extra Communication Card Quick Guide Extra Communication Card Uninterruptible Power Supply System Version: 1.0 Table of Contents 1. Product Outlook... 3 2. Product Introduction... 3 2.2. RS232 port... 4 2.3. COMM. Slot... 4 2.4.

More information

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It

More information

Switched Mode Power Supply Operating manual PAP800

Switched Mode Power Supply Operating manual PAP800 Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA The SR series on line double conversion UPS with full time Digital Signal Processor control technology is the perfect solution for mission critical users who demand high reliability, availability and performance

More information

Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430. Operation Manual

Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430. Operation Manual Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430 Operation Manual INDEX 1 Specifications 2 Assembly and installation 2.1 Precautions for installation 2.2 Installation of controller

More information

12V POWER SUPPLY / BATTERY CHARGER

12V POWER SUPPLY / BATTERY CHARGER Power Supply Power supplies are designed and manufactured by EDS to perform efficiently in a wide range of applications such as CCTV, Intrusion detection, Access control and Fire alarm systems. 12V / BATTERY

More information

Installation manual CF8-W-Disp-AL

Installation manual CF8-W-Disp-AL Installation manual CF8-W-Disp-AL CO 2 transmitter with two relays mounted in industrial housing prepared for Modbus communication protocol 4 7 8 8 6 3 2 5 Wall plate 5 Snap-in lid 2 PCB (Factory supplied

More information

Defining the Future in Motion Control

Defining the Future in Motion Control Defining the Future in Motion Control USER S MANUAL 1 DINIO7 user s manual Overview The DINIO7 is a DIN-rail mounted peripheral for the SmartMotor versions 3 and 4 product lines Hereafter, the SmartMotor

More information

Model (DRS-54V) Ver. 2.0 August. Dongah Rectifier System Operating Manual

Model (DRS-54V) Ver. 2.0 August. Dongah Rectifier System Operating Manual 2011 Model (DRS-54V) Ver. 2.0 August DRS-54V Dongah Rectifier System AC 240V 1Phase 3WIRE Input -54VDC Output 55A per Shelf 18.5Amps per Module DONGAHELECOMM.LTD _ Proprietary This document contains proprietary

More information

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA) POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA) A55-00017 SEC PLUS 8-10 KVA MAREKTING SPECS REV. A 9/10 8kVA, 10kVA POWERVAR Isolated On-Line UPS Specifications Index 1.0 General

More information

DSP Control. 0.9 Output Power Factor. Wide Input Range. High Efficiency Mode(ECO) Frequency Converter Mode. Input THDi<5% Output THDv<2%

DSP Control. 0.9 Output Power Factor. Wide Input Range. High Efficiency Mode(ECO) Frequency Converter Mode. Input THDi<5% Output THDv<2% NEW LINE Polaris RT 1-10 KVA UPS HIGH POWER DENSITY RACK-TOWER 2-IN-1 TRUE DOUBLE CONVERSION ONLINE UPS DSP Control 0.9 Output Power Factor Wide Input Range High Efficiency Mode(ECO) Frequency Converter

More information

Uninterruptible Power Supplies

Uninterruptible Power Supplies Xi Series 1-6kVA True On-Line UPS Features Rack-Mount/Standalone Format Universal Battery Design (Optional 10 year batteries) Dual Mains Input Dual Position Backlit LCD LCD Load Segment Control 2.5kVA

More information

1. Introduction External description Front and Rear Panel The LCD screen Alarm Conditions...6

1. Introduction External description Front and Rear Panel The LCD screen Alarm Conditions...6 Product Description LanPro 31 Contents: 1. Introduction...2 2. Functional explanation...2 2.1 Principles of Operation...2 2.2 Normal Conditions...3 2.3 Mains Failure...3 2.4 Bypass operation...4 3. External

More information

Please comply with all warnings and operating. instructions in this manual strictly. Save this. manual properly and read carefully the following

Please comply with all warnings and operating. instructions in this manual strictly. Save this. manual properly and read carefully the following Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this

More information

ADDENDUM FOR 20, 27, & 28 OPTIONS

ADDENDUM FOR 20, 27, & 28 OPTIONS ADDENDUM FOR 20, OPTIONS GENERAL The 20, 27, and 28 option provides for an alarm contact OR an AC transfer switch on EXELTECH XP Series inverters. The alarm relay monitors the inverter s AC output and

More information

Installation and Hardware Guide

Installation and Hardware Guide Helios W.E.S. 1000 & 2000 (Wireless Emergency Stop) Installation and Hardware Guide E5, Version 1.3 Helios Global Tech Ltd. Contact Information Helios Global Technologies 1920 Windsor Rd Kelowna BC V1Y

More information

Extra Communication Card Quick Start Guide

Extra Communication Card Quick Start Guide Extra Communication Card Quick Start Guide www.xpcc.com 2018. All rights reserved. (Rev 2/23/18) 1. Product Outlook... 3 2. Product Introduction... 3 2.2. RS232 port... 4 2.3. COMM. Slot... 4 2.4. Dry

More information

SmartLogger1000 Quick Guide. Issue: 10 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SmartLogger1000 Quick Guide. Issue: 10 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD. SmartLogger1000 Quick Guide Issue: 10 Part Number: 31505707 Date: 2017-06-13 HUAWEI TECHNOLOGIES CO., LTD. 1. The information in this document is subject to change without notice. Every effort has been

More information

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN

More information

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0 170 ADM 850 10 10 to 60 VDC Module Base / 170 ADO 830 30 6 Pt. Relay Out Module Base Version 1.0 31005197 00 Safety Information NOTICE Read these instructions carefully, and look at the equipment to become

More information

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1 PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits

More information

SNMP Web Management. User s Manual

SNMP Web Management. User s Manual SNMP Web Management User s Manual Suitable Product: SNMP Web Card SNMP Web Box Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2

More information

MAJOR VA Power Inverter

MAJOR VA Power Inverter MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in

More information

MODBUS-IN. Modbus Card. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

MODBUS-IN. Modbus Card. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved. MODBUS-IN User & Installation Manual www.xpcc.com 2014. All rights reserved. (Rev 12/17/14) Thank you for purchasing. This manual contains instructions and warnings that should be followed during the installation,

More information

Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control

Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control D1551A D1551B D1551P D1553B D1553C D1553P D1555B D1555C D1555P D155X Series Part Numbers 1A 12 volts in A box 1A

More information

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK TARGHA 200 A/200N AGATA C200 UK Installation Manual AGATAKIT C 200 UK 24806770/28-05-2013 AGK200C03UK HPC/1 AGATA C200 UK AG2K200C03UK HPC/2 HA/200 HBP AG3K200C03UK HPC/3 A/200N AGK200C03HNA HPC/1+HNA

More information

GXT 2U Configuration Program

GXT 2U Configuration Program POWER AVAILABILITY GXT 2U Configuration Program USER MANUAL Version 1.6 Table Of Contents TABLE OF CONTENTS Introduction and Requirements...3 Configuration Program Installation...4 Establishing Communication

More information

Allen-Bradley Drives

Allen-Bradley Drives Installation Data This document provides information on: important pre installation considerations power supply requirements installing the module installing and connecting the wiring using the module

More information

Installation Manual for D244X Series 24-volt Power Supplies

Installation Manual for D244X Series 24-volt Power Supplies Installation Manual for D244X Series 24-volt Power Supplies D2441-B D2441-C D2443-B D2443-C D2445-B D2445-C D2400 Series 1A 24 volts 1A 24 volts 3A 24 volts 3A 24 volts 5A 24 volts 5A 24 volts Dycon Power

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current Quattro-Relais Quattro Relay 4 Quattro Relay 4A4 Standard type / With LED and protection diode on request Quattro-Relais Order Code Order Code Quattro Relay 4 A 4 4 V DC N Type of relay Quattro Relay 4

More information

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions F7_F707_F708 Access Control Terminal Installation Instructions Revised May 2008 About this Guide This guide provides installation instructions only. For information regarding actual operation and configuration

More information

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet Digital Process Meters Digital Process Meter for analog Sensors Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does not form part

More information

EXPRESS SETUP. PanelMate 1700 Series PanelMate Power Pro. Cutler-Hammer

EXPRESS SETUP. PanelMate 1700 Series PanelMate Power Pro. Cutler-Hammer EXPRESS SETUP PanelMate 1700 Series PanelMate Power Pro Cutler-Hammer Installation Unpacking Carefully remove all equipment from the packing cartons and inspect all parts for damage in shipment. Check

More information

THOR Battery Backed DC Power Supply Reference Manual

THOR Battery Backed DC Power Supply Reference Manual THOR Battery Backed DC Power Supply Reference Manual Revision A Firmware Compatibility: V1.03 P/N 60098001 Revised: 4/26/2012 INDUSTRIAL CONTROL LINKS, INC. 12840 Earhart Avenue Auburn, CA 95602 Tel: (800)

More information

PowerMust Office Uninterruptible Power System

PowerMust Office Uninterruptible Power System USER MANUAL E PowerMust Office Uninterruptible Power System 614-05737-05 28-2PRO000001 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for Models PowerMust

More information

Installing Keypad and Backplate

Installing Keypad and Backplate Installing Keypad and Backplate Fig.1 Positioning of Fixing Holes and Cable Outlet Cable Outlet, Drill Diameter 10mm for Cable Access Remove the back plate, which is fitted to rear of the keypad, using

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

INSTALLATION & OPERATION MANUAL MODELS: RM RM IRM RM IRM RM RM

INSTALLATION & OPERATION MANUAL MODELS: RM RM IRM RM IRM RM RM INSTALLATION & OPERATION MANUAL MODELS: 24-1000RM 48-1000RM 48-1000IRM 48-2000RM 48-2000IRM 125-1000RM 125-2000RM Newmar 15272 Newsboy Circle Huntington Beach, CA 92649 Tel: 714.751.0488 www.poweringthenetwork.com

More information

KUUMIC OY DATA TRANSFER FALLBACK SWITCH KU113. Technical Reference

KUUMIC OY DATA TRANSFER FALLBACK SWITCH KU113. Technical Reference FALLBACK SWITCH Technical Reference CONTENTS 1. GENERAL...1 1.1. INTRODUCTION...1 1.1.1. Basic functions...1 1.2. TECHNICAL SPECIFICATIONS...3 1.2.1. CONNECTORS...3 1.2.2. LED INDICATORS...5 1.2.3. JUMPERS

More information

HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL

HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL DVS772HD HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL IB6445-01 DESCRIPTION The DVS772HD high definition DIGITAL VIDEO SWITCH is a high isolation high frequency relay used to switch digital signals

More information

02/11/2015

02/11/2015 24 x 48 Hour CTR24 non-backlit model Part number 87622162 Display : 8-digit LCD, height 8 mm Built-in module for voltage inputs 10 260 VAC/DC () 4 timing ranges : 99,999.99 hrs - 99,999.59 hrs - 999,999.9

More information

CompactPCI SYSTEM POWER SUPPLIES. CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input FEATURES:

CompactPCI SYSTEM POWER SUPPLIES. CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input FEATURES: CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input FEATURES: EXECUTIVE MEMBER 150 W and 200 W in 3U x 8HP, 350 W in 6U x 8HP Fully compliant with PICMG CompactPCI

More information

EMS467 Monitoring System. Installation and Operations Manual Section 40

EMS467 Monitoring System. Installation and Operations Manual Section 40 EMS467 Monitoring System Installation and Operations Manual 00-02-0672 01-26-10 Section 40 In order to consistently bring you the highest quality, full featured products, we reserve the right to change

More information

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control 1. INTRODUCTION User Manual This family of efficient, upgraded SMPS with small form factor,

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.: Technical Documentation VISY-Output 8 8-Channel relay output module Version: 3 Edition: 2016-09 Art. no.: 350072 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Germany Tel.: +49 / 40 / 39 82 07 0 Fax:

More information

User Manual. Solar Inverter for Water Pump

User Manual. Solar Inverter for Water Pump User Manual Solar Inverter for Water Pump SP Revival Series Version: 1.2 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...

More information

C4 SAFETY CHARGE PUMP BOARD Rev. 6.2

C4 SAFETY CHARGE PUMP BOARD Rev. 6.2 C4 SAFETY CHARGE PUMP BOARD Rev. 6.2 User manual Rev. 1 1. Overview. This board takes advantage of Mach ability to send a specific frequency through one of the pins of the parallel port when the program

More information

Liebert IntelliSlot Relay Card

Liebert IntelliSlot Relay Card Infrastructure Management & Monitoring For Business-Critical Continuity Liebert IntelliSlot Relay Card User Manual TABLE OF CONTENTS 1.0 INTRODUCTION............................... 1 Inspecting Shipment

More information

midon design A 1-Wire Multi-purpose Sensor 1WIO Figure 1 MD2083 As-Shipped August 23, WIO User Guide Version 1.

midon design A 1-Wire Multi-purpose Sensor 1WIO Figure 1 MD2083 As-Shipped August 23, WIO User Guide Version 1. A 1-Wire Multi-purpose Sensor 1WIO Figure 1 MD2083 As-Shipped August 23, 2009 1WIO User Guide Version 1.7 Page 1 of 14 1WIO User Guide Version 1.7 1. Table of Contents 1. Table of Contents...2 1.1. List

More information

UPS Emergency Bed Power Unit

UPS Emergency Bed Power Unit UPS Emergency Bed Power Unit Ergonomic Design with extending Carry Handle Wide Input Voltage Range Compatible with Generators Optional LED Light Audible Alarm Functions Full-time Surge Protection Protection

More information

Foreword: The purpose of this document is to describe how to install and configure Neets 2 relay box with build-in power supply.

Foreword: The purpose of this document is to describe how to install and configure Neets 2 relay box with build-in power supply. Foreword: The purpose of this document is to describe how to install and configure Neets 2 relay box with build-in power supply. COPYRIGHT - All information contained in this manual is the intellectual

More information

SER-4485-SI-M USER S MANUAL

SER-4485-SI-M USER S MANUAL SER-4485-SI-M USER S MANUAL 2017 May Edition Titan Electronics Inc. Web: www.titan.tw The computer programs provided with the hardware are supplied under a license. The software provided should be used

More information

USER S MANUAL. C4 SAFETY CHARGE PUMP BOARD Rev. 6.2

USER S MANUAL. C4 SAFETY CHARGE PUMP BOARD Rev. 6.2 USER S MANUAL C4 SAFETY CHARGE PUMP BOARD Rev. 6.2 March 2013 USER'S MANUAL TABLE OF CONTENTS Page # Contents 1.0 OVERVIEW... 1 2.0 FEATURES... 1 3.0 SPECIFICATIONS... 2 4.0 SIMPLIFIED SCHEMAT... 2 5.0

More information

Hardware User s Manual. Digital Video Motion Detector DVMD1-X

Hardware User s Manual. Digital Video Motion Detector DVMD1-X Hardware User s Manual Digital Video Motion Detector DVMD1-X Version 010 Revision A July, 2004 2395 Kenwood Drive Boulder, CO 80303 (303) 543-0440 TECHNICAL SPECIFICATIONS VENDOR Radiant Inc. http://www.dvmd.com

More information

SCR100 User Manual. Version:1.1 Date:Dec 2009

SCR100 User Manual. Version:1.1 Date:Dec 2009 SCR100 User Manual Version:1.1 Date:Dec 2009 Introduction: This document mainly introduces the installations and connections of SCR100 products, and the brief operations about attendance software. Important

More information

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

Wiring Inside the card reader you will see a circuit board. The connections are as follows: Power Adaptor (12VDC, Max. Current: 1A) If you purchased the Cardlock Series power supply cut the head of the adaptor and strip the insulation. If your locking mechanism, electric strike or magnetic lock

More information

Ocean Controls KTA-224 Modbus IO Module

Ocean Controls KTA-224 Modbus IO Module Ocean Controls Ocean Controls 8 Relay outputs (5A, 250VAC contacts) 4 Opto-Isolated Inputs with counters 3 Analog Inputs (10 bit) jumperselectable for 0-5V or 0-20mA 4 Input Counters RS485 or USB (virtual

More information

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014 SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions

More information

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual AC-015 Single- Access Control Programmer Hardware Installation and Programming Manual Copyright 2014 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to

More information

7.6 DI Technical Data. 140 DI135 Chapter 3. General Information

7.6 DI Technical Data. 140 DI135 Chapter 3. General Information 7.6 DI135 7.6.1 Technical Data Module ID General Information Model Number Short Description C-UL-US Listed DI135 7DI135.70 2003 digital input module, 4 inputs 24 VDC, sink, incremental encoder operation:

More information

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications 12 Universal Expander Module. Installation Notes. Revision 1.2 August. 2003. 1 Reporting Reporting with most Contact ID maps will treat the Mini Expander, Exp32 and Exp16 as the same. (With the exception

More information

AirTest Model CN9000 Series Sensor Controller

AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

SitePORTAL Lite TA-SPL32-R48

SitePORTAL Lite TA-SPL32-R48 SitePORTAL Lite TA-SPL32-R48 Quick Connect Guide The TA-SPL32-R48 is a 19 inch, 2 RU rack mountable siteportal Lite (spl). It comes with 8 analog inputs, 8 temperature inputs (sensors sold separately),

More information

Ohm Metrics. Instruction Manual. Dual Footwear Wrist Strap Tester Model PDT800K

Ohm Metrics. Instruction Manual. Dual Footwear Wrist Strap Tester Model PDT800K T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L Ohm Metrics Dual Footwear Wrist Strap Tester Model PDT800K Instruction

More information

Intelligent Channel Bank Shelf

Intelligent Channel Bank Shelf Telecommunications Group Section 360-080-204 Equipment Issue 4 Third Printing, August 2006 360-80 Intelligent Channel Bank Shelf CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

A0750 AC-DC POWER MODULE

A0750 AC-DC POWER MODULE FEATURES High power density, 7.7W / in³ Net Weight:< 2.2 KG Low profile : 40.8mm (fit 1U 19 shelf R2250 series) Efficiency: 77% ~ 86 % typical Power factor correction (meet IEC1000-3-2 requirements) Overvoltage

More information

PC2004 PRESSURE CONTROLLER

PC2004 PRESSURE CONTROLLER PC CTROLLER FRT PANEL Digital Display & Display Selector Switch The Display Selector Switch has five positions: PRESS Displays the pressure sensed at the transducer. INT SP Displays the INTERNAL SETPOINT

More information

Fingerprint Access Control F1. User Manual

Fingerprint Access Control F1. User Manual Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.

More information

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL Copyright 1997-2005, Audio Technologies Incorporated - Printed in USA DESCRIPTION Your L200 Dual Line/Buffer Amplifier is an inexpensive, high

More information

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication. 3-3 Wiring NQ-Series models have, besides one power connector, a number of communication ports. Please refer to Table 2.2: Common specifications for NQ-Series and Table 2.3: Specifications per NQ-Series

More information

UP200-GSM Intercom and access control unit operating on mobile GSM network

UP200-GSM Intercom and access control unit operating on mobile GSM network UP200-GSM Intercom and access control unit operating on mobile GSM network INTRODUCTION The UP200-GSM is an intercom unit which as a cell phone can call the owner s mobile or landline phone. By pressing

More information

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A Table of Contents 1. Important Safety Instructions... 2 2. Overview... 3 3. Product Functional Description... 4 3.1. Front Panel... 4 3.2. LCD Display Description... 5 3.3. Rear Panel... 6 3.4. Communication

More information

FEATURES DESCRIPTION FEATURES

FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs 24 Sinking or Sourcing Inputs 16 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate

More information

2-Way Wireless I/O Expander Installation Guide

2-Way Wireless I/O Expander Installation Guide 2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...

More information

Communi-Cell Communicator Nokia Version

Communi-Cell Communicator Nokia Version Communi-Cell Communicator Nokia Version Jan 2007 Instruction Manual 1 ABOUT THE COMMUNI-CELL COMMUNICATOR SYSTEM The Communi-Cell Communicator system is based on GSM SMS technology. It uses a standard

More information

GENERAL QUICK START GUIDE

GENERAL QUICK START GUIDE GENERAL QUICK START GUIDE 2.8InchPalm & Fingerprint Time Attendance & Access Terminal Version: 1.0 Date: May., 2017 Note: The picture and function presented in this manual are only for reference. The following

More information

smartentry Wireless Video Doorphone User Manual

smartentry Wireless Video Doorphone User Manual smartentry Wireless Video Doorphone User Manual Designed & Engineered Version 1.2 in the United Kingdom Contents Precautions... 3 1. Product Overview... 4 1.1. Product Features... 4 1.2. Contents... 4

More information