Two Door Controller GEN-045

Size: px
Start display at page:

Download "Two Door Controller GEN-045"

Transcription

1 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd Distributed by: Genesis reserves the right to change or modify products without notice. This manual assumes installers of this product are professionals within the electronic security, access control and automation industry. As such, knowledge of these industries on the part of the installer is assumed. Genesis takes no responsibility for any damage, financial loss or injury caused to any equipment, property or persons resulting from the correct or incorrect use of any Genesis Electronics devices. genesis The very latest innovation in security and access Page 16 Revision 2.07 September 2002 TECHNICAL MANUAL Revision 2.07 September 2002 Genesis Electronics Australia Pty Ltd

2 Table of Contents Notes TABLE OF CONTENTS 2 PARTS CHECKLIST 3 SPECIFICATIONS 3 FEATURES AND BENEFITS 4 TERMINAL BLOCK MOUNTING 5 TWO DOOR CONTROLLER LAYOUT 6 MOUNTING 11 GENESIS LAN 12 POINTS TO NOTE 14 Page 2 Revision 2.07 September 2002 Version 2.7 September 2002 Page 15

3 Points to Note: It is recommended to use a separate power supply, located near the Two Door Controller. DO NOT common the 0V DC, or +12V DC, of power supplies and Genesis devices. When using the Two Door Controller to control an electric strike or magnetic lock, it is recommended to use separate power supplies for both the Two Door Controller power and for the locking device power. Removal of the Serial Number from any Genesis device will immediately void any warranty applicable to it, or any interconnected Genesis device. Caution: When connecting an electric strike, relay or other inductive load to the Two Door Controller, it is important to insert a protection diode in parallel with the load. This is to prevent any back EMF generated by the inductive load, from effecting or damaging any equipment connected to the power supply. Power Supply + - C NO NC Door Strike + - Diode type 1N-4004 to be fitted as close to strike as possible Page 14 Revision 2.07 September 2002 Parts Checklist: 1 x Two Door Controller (GEN-045) 8 x 2 pin terminal blocks 2 x 3 pin terminal blocks 3 x 2 pin jumpers 1 x 2 pin header 4 x mounting screws 1 x Two Door Controller Technical Manual (this manual) Specifications: Dimensions (H x W x D): Input Voltage: Standby Current Draw: Processor: Memory: Door Controllers: Inputs Egress: Door Monitoring: Outputs Door Outputs: Open Collector Outputs: Buzzer: 140 x 80x 30 mm 11-16V DC 35mA 16 bit microprocessor 256k ROM and 20k RAM 2 x Wiegand Readers 2 x Normally Open 2 x Normally Closed 2 x Change Over Contact Relays 4 x technician programmable open collector outputs Programmable Piezo Buzzer Caution: All Genesis devices are electrostatic sensitive devices. As such, all care should be taken to ensure appropriate procedures are in place when handling and installing Genesis devices. This may include, but is not limited to wearing an appropriately earthed, conductive wrist strap to limit electrostatic discharge into Genesis devices. Version 2.7 September 2002 Page 3

4 Features and Benefits: The Genesis Two Door Controller unit is not just a simple two door interface. The Genesis Two Door Controller provides two Wiegand inputs for proximity readers, two door inputs for door status monitoring and two request to exit inputs for door release. The Two Door Controller also includes two high current, change over contact relays for electric lock release and four open collector outputs for LED or buzzer indication at the reader. The Genesis Two Door Controller gives you flexibility you can build upon. Flexible input allocation allows you to easily convert unused egress button inputs into standard zone inputs, from the Genesis Technician Software. Two wire RS-485 LAN communication allows the Two Door Controller to be mounted up to 1500 metres from the master unit. An integrated, 100 card user cache allows the last 100 card users through each door to continue using that door in case of communication failure with the master unit. As an installation grows in size, you can install up to 192 access doors utilizing either Two Door Controllers, or Genesis Remote Access Stations. Genesis LAN (cont.): Connect to Communications Earth Master Unit GEN001 Remote Access Station GEN030 Expander Unit GEN010 SHD B A SHD B A SHD B A The Master Unit must always be the first device on the LAN. This device is factory fitted with a 180Ω LAN Termination Resistor. The shield from the LAN cable should run the length of the LAN, and should be connected to a communications earth, at the Master Unit only. The shield terminals on each device are for connection of shield cables, and do not connect to the device proper in any way Up to 127 additional Genesis devices in total can be connected to the Genesis LAN, across a total LAN length of up to 1500 meters. The last device on the Genesis LAN must be fitted with its termination link. This link fits a 180Ω resistor to the last device on the LAN. No other devices should have a termination link fitted. If connected as described above, the LAN should have an impedance of approximately 90Ω, plus the resistance of the LAN cable. *Don t test LAN impedance with any devices powered up. The Genesis Two Door Controller includes an on board RS-232 interface, aswell as an integrated tamper monitoring input and low voltage monitoring. The built in piezo buzzer can be used for system indications, or be used to simply assist security technicians in finding devices. Two Door Controller GEN045 SHD B A Ensure the cable shield is not connected to any ground or to any voltage on any device and that the cable shield is only connected to a communications earth at the Master. Correct LAN configuration Correct LAN Configuration Page 4 Revision 2.07 September 2002 Version 2.7 September 2002 Page 13

5 Genesis LAN: Genesis uses industry standard RS-485 LAN communication to ensure fast efficient network communication between devices. The Genesis LAN operates at a communication speed of 19,200 baud between up to 128 devices over a total LAN distance of up to 1500 meters. In order to ensure that a high level of performance is achieved, it is necessary to connect the Genesis LAN in the recommended method. To this end, it must be twisted pair data cable that is used for the Genesis LAN. Belden 8723 (RS-485) cable, or equivalent is recommended. A standard must be applied when wiring from one LAN leg to another. For example, the A leg on a Master Unit must always be connected to the A legs on other Genesis devices, while the B leg must always be connected to the B legs on other Genesis devices. A very common communication problem is where the A and B lines are reversed. If this occurs, then some devices may appear on-line, while others are off-line. Terminal block mounting: Door input terminals 12V DC Power input terminals The Genesis LAN is an industry standard multi-drop RS-485 configuration. Do Not Tee Off, or Star configure your LAN. While the LAN may function in these configurations, Genesis cannot guarantee proper LAN performance. X X Improper Star Configuration Improper Tee Off Configuration Relay output terminals LAN terminals Page 12 Revision 2.07 September 2002 Version 2.7 September 2002 Page 5

6 Two Door Controller layout: Door 1 Prox 1 Door 1 Reader Input: This terminal allows for connection of a wiegand or genesis format reader, in the following layout: 0V Black Data 1 White Data 0 Green +12V DC Red Door 1 - Door Monitoring Input: This terminal allows for connection of a reed switch or other door monitoring device, to provide Door Open To Long, or Door Forced alarm functionality. Mounting: The Two Door Controller is designed to mount within the GEN-130, metal equipment cabinet. Using this cabinet, it is possible to mount up to 5 Two Door Controllers within the one cabinet, or any other combination of Genesis equipment may also be mounted with the Two Door Controller. - The four screws supplied with the Two Door Controller are for securing the controller to the stand-offs on the GEN Avoid installing the Two Door Controller outdoors. - Avoid installing the Two Door Controller where it may be exposed to moisture, either directly (Rain, Sprinklers, Hoses), or by condensation. Exit 1 Egress Button Input: This terminal allows for connection of an egress button to release the Door 1 Relay. Door 1 Door 1 Relay Contact: This terminal provides a N/O and N/C relay contact, to allow switching control of a door release, or door locking mechanism. C Relay Common NO Normally Open Contact NC Normally Closed Contact As default the relay is dry contact only, however it is possible to source and sink 12V DC at up to 100mA, by fitting a jumper to link H19. This provides 12V DC to the common terminal of the relay. Page 6 Revision 2.07 September 2002 Version 2.7 September 2002 Page 11

7 Two Door Controller layout: 12V DC POWER INPUT TERMINALS Supplied for connection of 12V DC to power the module. Genesis recommends only using factory recommended power supplies with Genesis devices. RS-232 PORT Use to allow connection to User Interface Software, or other third party device driven by RS-232. Only available for use if enabled in Genesis Technician Software. Two Door Controller layout: Door 2 Prox 2 Door 2 Reader Input: This terminal allows for connection of a wiegand or genesis format reader, in the following layout: 0V Black Data 1 White Data 0 Green +12V DC Red Door 2 - Door Monitoring Input: This terminal allows for connection of a reed switch or other door monitoring device, to provide Door Open To Long, or Door Forced alarm functionality. Exit 2 Egress Button Input: This terminal allows for connection of an egress button to release the Door 1 Relay. Door 2 Door 2 Relay Contact: This terminal provides a N/O and N/C relay contact, to allow switching control of a door release, or door locking mechanism. C Relay Common NO Normally Open Contact NC Normally Closed Contact ON BOARD PIEZO BUZZER Supplied to allow audible indication from the Genesis device, this Piezo Buzzer is fully programmable and controllable from within the Genesis Technician Software. As default the relay is dry contact only, however it is possible to source and sink 12V DC at up to 100mA, by fitting a jumper to link H20. This provides 12V DC to the common terminal of the relay. Page 10 Revision 2.07 September 2002 Version 2.7 September 2002 Page 7

8 Two Door Controller layout: OPEN COLLECTORS: 4 fully programmable open collector outputs are supplied, capable of sinking up to 100mA each. As displayed the terminals are: +12VDC H3 LAN TERMINATION LINK: The LAN Termination Link should only be fitted on the last device on the Genesis LAN. Please refer to page 12 for further information on the Genesis LAN. TAMPER INPUT: Provided to allow normally closed connection of a cabinet tamper to this device. LAN TERMINALS: The A and B LAN terminals are designed for the Genesis LAN to be terminated into. The A and B lines must always be connected to the A and B terminals on other Genesis devices. The shield (SHLD) terminal has been supplied to secure the cable shield only. Please refer to page 12 for further information on the Genesis LAN. H19 and H20 pins: These supply 12V DC to the common terminals of the relays when shorted. These pins can source a maximum of 100mA each. Two Door Controller layout: ALIVE and NET LED s Provides a quick indication as to system status. Flashing ALIVE LED = Device Processor OK. Flashing NET LED = LAN Comms OK SWIPE 1 and SWIPE 2 Reserved for future use. PROGRAMMING HEADER The programming header is supplied to allow easy flash upgrading to any future Genesis features. Please contact your distributor for more details. RESET BUTTON Used when generating a hardware reset to the device processor. Use only under instruction from your Genesis Distributor. SERIAL NUMBER Each Genesis device is fitted with it s own unique Serial Number. This number will need to be entered into the Genesis Master Unit, via the technician software, before the device will come on line. Removal of Serial Number will void Warranty LINK 1 Reserved for future use. Do NOT fit a jumper to this link Page 8 Revision 2.07 September 2002 Version 2.7 September 2002 Page 9

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

genesis TECHNICAL MANUAL Two-Door Controller GEN-045 Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010 Australian Owned, Designed and Manufactured Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products

More information

genesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured

genesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Australian Owned, Designed and Manufactured Master Unit GEN-001 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products

More information

genesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010

genesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010 16-Input Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

genesis genesis I/O Expander - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured I/O Expander GEN-020

genesis genesis I/O Expander - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured I/O Expander GEN-020 Australian Owned, Designed and Manufactured I/O Expander GEN-020 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09 CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

DG-800 Stand-Alone Proximity Reader Instruction Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual P/N MAINST-867/869 REV 07 ISS 26NOV13 Copyright Trademarks and patents Manufacturer ACMA compliance Contact information 2013 UTC Fire

More information

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1 15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...

More information

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It

More information

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Quick Start Guide. SEB-710 I/O Expansion board. Introduction SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay

More information

180 Series Keypad. Handbook. Revision 2.1

180 Series Keypad. Handbook. Revision 2.1 180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

CP150B Vandal & Weather Resistant Keypad Security Systems

CP150B Vandal & Weather Resistant Keypad Security Systems Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected

More information

Suprex RS-485 SPX-7500 Wired Reader-Extender

Suprex RS-485 SPX-7500 Wired Reader-Extender Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778

More information

Waterproof. Keypad/Reader/Controller

Waterproof. Keypad/Reader/Controller Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing

More information

PR602LCD v1.0 Installer Manual Rev. A

PR602LCD v1.0 Installer Manual Rev. A PR602LCD v1.0 Installer Manual Rev. A Introduction This document contents minimum information required for electrical connections and installation of the PR602LCD access controller in Roger Access Control

More information

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014 SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions

More information

MR52 READER INTERFACE

MR52 READER INTERFACE IN IN2 IN3 IN4 INPUTS IN5 IN6 IN7 IN8 C www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 9085-755, (562)986-905 FAX (562) 986-9205 MR52 READER INTERFACE Installation and Specifications: This

More information

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work

More information

istar Pro Installation Guide

istar Pro Installation Guide istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general

More information

CM-500 SK 500 USER CODES KEYPAD

CM-500 SK 500 USER CODES KEYPAD CM-500 SK 500 USER CODES KEYPAD Wiring diagram PCB front view ST2 1 3 1 3 N/C contact RL1 (magnet) N/O contact RL1 (strike) ST1 3 2 1 ST2 1 3 RL2 RL1 Strike 2 1 E M B 3 5 T C O 12 V V1 PB2 PB1 Input voltage

More information

FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS:

FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS: FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS: 233CARDREADER DOOR-GARD SELF-CONTAINED ACCESS CONTROL SYSTEMS offer field proven reliability and cost effective solutions for residential,

More information

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual RD-SR2 Proximity Card Reader with Remote Control User Manual INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control

More information

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated: Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact

More information

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader Features: Rugged construction heavy-duty stainless steel faceplate with coated steel housing Built-in proximity card reader 12~24

More information

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL Revision 2.1 July. 2014 1 Integriti 8 32 Zone LAN Expander Module Kit P/N: 996005PCB&K For Rev. B PCB. INSTALLATION MANUAL Overview The Integriti 8 Zone Expander Module provides an additional 8 Zone inputs,

More information

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4

More information

SINGLE READER EXPANSION MODULE

SINGLE READER EXPANSION MODULE SINGLE READER EXPANSION MODULE INSTALLATION GUIDE A D C - A C X 1 TR- SINGLE READER EXPANSION MODULE The ADC-ACX1 Single Reader Expansion Module provides a solution for interfacing to a one Wiegand reader

More information

Single Door Standalone Access Control User Manual

Single Door Standalone Access Control User Manual Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

RFID/Digital Access Control Keypad

RFID/Digital Access Control Keypad R Luminous/ RFID/Digital Access Control Keypad Model:YK-368L-R Germany EMC tested FEATURES AND FUNCTIONS Simple Programming, Easy Operation 3-Operation Mode: ID Card Operation, User Code Operation, ID

More information

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Introduction This document contains minimum information that is necessary to properly install the device and to perform its

More information

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

W3-H Waterproof Keypad/Reader/Controller

W3-H Waterproof Keypad/Reader/Controller W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark

More information

User Manual. PCKeypad Wireless Keypad

User Manual. PCKeypad Wireless Keypad User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option

More information

Access Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64

Access Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64 Essential Essential Plus Elite 36 Elite 64 Access Control System Document Number: 620-100239, Rev. D Installation Guide USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800)

More information

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

Installation Manual. Contents

Installation Manual. Contents CONCEPT IQ. Combined Installation Manual Rev 1.0 05/03 p1 Installation Manual Contents Section One: Concept IQ Hardware Overview 1.1 Typical Installation 1.2 Concept IQ Lockable Cabinet 1.3 Connecting

More information

212iL Rev. 1.1

212iL Rev. 1.1 212iL 1 International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iL (illuminated Luxury) Keypad Single Unit Keypad- Control Installation Manual Features: 120 User Capability Illuminated

More information

SmartLock Pro INSTALLATION MANUAL

SmartLock Pro INSTALLATION MANUAL SmartLock Pro INSTALLATI MANUAL July 2010 Cutting edge simplicity Table of Contents INTRODUCTI... 3 Diodes... 3 Power Supply Notice... 3 Terminal Strips and Cable... 4 SPECIFICATIS... 5 SMARTLOCK CTROLLER

More information

SmartLock Controller INSTALLATION MANUAL

SmartLock Controller INSTALLATION MANUAL SmartLock Controller INSTALLATI MANUAL November 2015 Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting...

More information

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL PAD Programming & Installation Manual An Innovative Product Developed By: PROTECT - ON SYSTEMS LTD. MANUFACTURED BY: 20 R SINCE 1979 ADVANCED ELECTRONICS

More information

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating 1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without

More information

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated: Wiring Guide EP.L3800 Version 1.03 Last Updated: 13-10-2014 1 Note: L3800 is the serial enabled lift controller. L3800 will ship with a HIO board in a package which can cater up to 8 floors. It can connect

More information

W3-M. Metal waterproof standalone access control/reader. User Manual

W3-M. Metal waterproof standalone access control/reader. User Manual W3M Metal waterproof standalone access control/reader User Manual Name Digital Keypad W3M User Manual Screw driver Rubber bungs Selftapping screws Diode 1. Packing List Quantity 1 1 1 4 4 1 Remark 6*27mm,

More information

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

Wiring Guide EP.NMINI. Version 1.02 Last Updated: Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass

More information

MR50 READER INTERFACE

MR50 READER INTERFACE 2.75 [69.9] 2.35 [59.7] U1 MR50 READER INTERFAE Installation and Specifications: 1. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEAH, A 90815-1755, (562)986-9105 FAX (562) 986-9205 This device

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

Cardax FT Controller 3000

Cardax FT Controller 3000 Installation Note Cardax FT Controller 000 CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any

More information

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode -Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add

More information

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description. SL2000E Electronic Code Lock Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming/disarming

More information

PR402 v2.0 Installer Manual Rev.C

PR402 v2.0 Installer Manual Rev.C PR402 v2.0 Installer Manual Rev.C Introduction This document contents minimum information required for electrical connections, installation and initial tests of PR402 access controller. Installation The

More information

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3 INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: June, 2016 Version: 1.3 2 What s in the Box 2 Screws & Anchors 2 Screwdriver 4 Diode CONTENT Contents What s in the Box...2 Optional accessories...4

More information

MR51e Reader Interface

MR51e Reader Interface J4 J TB6 TB5 TB4 TB3 VIN VO TB2 TB J7 2.75 [69.85] 0.2 [5.08] 2.35 [59.69] J3 MR5e Reader Interface Installation and Specifications. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA

More information

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board *P516-097* P516-097 PIB300 and PIB301 User Guide Installation and operation instructions for Panel Interface Board Para el idioma español, navegue hacia www.schlage.com/support Pour la portion française,

More information

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

Wiring Inside the card reader you will see a circuit board. The connections are as follows: Power Adaptor (12VDC, Max. Current: 1A) If you purchased the Cardlock Series power supply cut the head of the adaptor and strip the insulation. If your locking mechanism, electric strike or magnetic lock

More information

RBR-SB-KTZ001 LAR 2. User Manual

RBR-SB-KTZ001 LAR 2. User Manual RBR-SB-KTZ001 LAR 2 User Manual INTRODUCTION KTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. Read both EM and HID card.

More information

IPassan Installation guide

IPassan Installation guide IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...

More information

PAC1 Door Access Controller

PAC1 Door Access Controller PAC1 Door Access Controller Series 1 TABLE OF CONTENTS i PAGE Introduction...1 Features...1 Specifications...2 Terminal Descriptions...3 Programmable Features Description...5 Automatic Relock Function...5

More information

PRO3200 Professional Modular Access Control Hardware

PRO3200 Professional Modular Access Control Hardware PRO3200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO3200 professional modular access control hardware is an advanced access control panel capable of providing

More information

Stand-alone Proximity Access Control

Stand-alone Proximity Access Control Stand-alone Proximity Access Control User Manual INTRODUCTION VIDI-AC-1C is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. It uses

More information

PAC2 Dual Door Access Controller

PAC2 Dual Door Access Controller PAC2 Dual Door Access Controller Series 2 IMPORTANT DIFFERENCES FROM SERIES 1 1. All programming can only be done through devices attached to DTA1. 2. A PACDL data logger revision 4.0 or higher attached

More information

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.

More information

EL-ST100 KEYPAD CONTROLLER

EL-ST100 KEYPAD CONTROLLER WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6

More information

PAC1 Door Access Controller

PAC1 Door Access Controller PAC1 Door Access Controller Series 1 100% Designed and Manufactured by: NIDAC SECURITY PTY. LTD. 2 CROMWELL STREET BURWOOD, VICTORIA Tel: (03) 9808 6244 AUSTRALIA 3125 Fax: (03) 9808 9335 Revision 1.1

More information

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control STALLATION GUIDE.4 Inch TFT Terminal Time Attendance & Access Control Optional accessories Safety Precautions The following precautions are to keep user s safe and prevent any damage. Please read carefully

More information

Wiring Instructions v4

Wiring Instructions v4 Wiring Instructions v4 GateKeeper h4.2 Technical Support support@gymmastersoftware.com USA: 415 678 1270 Australia: 03 9111 0323 : 03 974 9169 Copyright 2018 Treshna Enterprises. All rights reserved. 15

More information

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch Finger Vein Terminal Time Attendance & Access Control Version: 1.0 Date: Apr., 2017 1 2.4-Inch TFT LCD USB Storage Device Port Keypad& Card Reader Doorbell & LED Indicator Fingerprint

More information

MS-3000 MicroStar Reader

MS-3000 MicroStar Reader MicroStar Reader The MicroStar Reader The MicroStar Reader is intended for installation on a window mullion or a door frame, on or off metal, in proximity applications where an unobtrusive reader is required.

More information

EP1501 Intelligent Controller

EP1501 Intelligent Controller J6 BT K K2 TB5 TB 2.35 [59.69] 2.75 [69.85] EP50 Intelligent Controller with Paired Reader Interface for One Physical Barrier Installation and Specifications: www.mercury-security.com 2355 MIRA MAR AVE.

More information

SCR100 User Manual. Version:1.1 Date:Dec 2009

SCR100 User Manual. Version:1.1 Date:Dec 2009 SCR100 User Manual Version:1.1 Date:Dec 2009 Introduction: This document mainly introduces the installations and connections of SCR100 products, and the brief operations about attendance software. Important

More information

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502 Suprex Fiber Optic Reader-Extender SPX-7400 SPX-7410 Product Manual Reader-Extender Manual SPX-7400 Series EXP-2000 Suprex_FiberOptic_MAN_170502 Cypress Integration Solutions 30+ Years of Access Control

More information

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology THE BRIDGE Make any Wiegand device wireless with the Surefi Bridge *Housing options sold separately. Keep your Wiegand system connected. Fix faulty Wiegand systems quickly and easily with our wireless

More information

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad

More information

Zodiac FR100 TM INSTALLATION MANUAL

Zodiac FR100 TM INSTALLATION MANUAL Zodiac FR100 TM INSTALLATION MANUAL June 2014 Table of Contents INTRODUCTION... 3 SPECIFICATIONS... 4 Diodes... 5 Terminal Strips and Cable... 5 READER LAYOUT... 6 READER INSTALLATION... 7 Mounting Plate...

More information

WAC-IPMG200 IP Based Access Control System

WAC-IPMG200 IP Based Access Control System WAC-IPMG200 IP Based Access Control System 1. Technical Specifications 2 Door Controller Size (box) 350mm x 360mm x 85mm Temperature -5 C to +50 C Power Main Power : 220-240VAC, 50/50Hz, Power for main

More information

CA111x-series Arming Station

CA111x-series Arming Station GE Security CA111x-series Arming Station Installation and Programming Guide Contents Page Product Overview...1 Removing the Covers...2 Mounting the RAS...3 Tamper Switch...3 DIP Switch Settings...3 Connections...4

More information

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver

More information

Suprex Ethernet SPX-7200 Ethernet Reader-Extender

Suprex Ethernet SPX-7200 Ethernet Reader-Extender Suprex Ethernet SPX-7200 Ethernet Reader-Extender Product Manual 1 SPX-7200_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems

More information

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual secure open Keypad CT Art. No.:, (black) Art. No.:, (white) Installation Manual CT_installation_ENGmay Conlan ApS Speditorvej A DK- Aalborg Tel: + Fax: + www.conlan.eu info@conlan.eu Table of contents.

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,

More information

NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel.

NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel. Revised! see Protective Earthing Addendum cback NOTE: This equipment must only be installed and serviced by professional qualified personnel. The Network Concentrator Link is a fully self contained unit

More information

-DTZ001- Stand-Alone Proximity Access Control. User Manual

-DTZ001- Stand-Alone Proximity Access Control. User Manual -DTZ001- Stand-Alone Proximity Access Control User Manual INTRODUCTION DTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users,

More information

Installation and User Manual

Installation and User Manual S2 Metal Waterproof Access Control Unit Installation and User Manual (Ness Part No. 101-082) 1 Introduction Ness S2 is an advanced, waterproof (IP65 rated) proximity and PIN Access Controller. S2 can support

More information

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

CYPRESS   EXP SPX Expansion interface! modules EXP-2000_MAN_0314 CYPRESS EXP-2000 SPX Expansion interface! modules The EXP-2000 provides additional Door/Panel interface points to most SPX products. The EXP-2000 uses a local RS-485 network through an SPX gateway device.

More information

VIDI-AC-2CS Access Controller/ Reader

VIDI-AC-2CS Access Controller/ Reader VIDI-AC-2CS Access Controller/ Reader User Manual CONTENTS INTRODUCTION 2 INSTALLATION.4 STANDALONE MODE 6 CONTROLLER MODE.11 WIEGAND READER MODE.. 13 ADVANCE APPLICATION..14 1 INTRODUCTION The VIDI-AC-2CS

More information

Installation Guide. Avigilon ACM Embedded Controller

Installation Guide. Avigilon ACM Embedded Controller Installation Guide Avigilon ACM Embedded Controller 2016, Avigilon Corporation. Portions 2003-2014 HID Global Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER and ACM

More information

TAC I/NETTM 1284, 1280, Security Control Unit

TAC I/NETTM 1284, 1280, Security Control Unit TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring

More information

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications The MiniStar Reader The MiniStar Reader is intended for installation in a single gang electrical "J-Box," in proximity applications where an unobtrusive reader is required. It can also be mounted directly

More information

emerge Essential Access Control System

emerge Essential Access Control System emerge Essential Access ontrol System Document Number: 620-100239, Rev. Installation Guide Linear LL 1950 amino Vida Roble, Suite 150 arlsbad, A 92008-6517 www.linearcorp.com Notices All rights strictly

More information

Installation guide for PR612, PR622, PR312EM, PR312EM-BK, PR312MF and PR312MF-BK access controllers

Installation guide for PR612, PR622, PR312EM, PR312EM-BK, PR312MF and PR312MF-BK access controllers Roger Access Control System Installation guide for PR612, PR622, PR312EM, PR312EM-BK, PR312MF and PR312MF-BK access controllers Firmware version: 1.18.6 or newer Document version: Rev. G 2016 ROGER sp.

More information