IT solutions. News 2003 Additions to the IT Catalogue

Size: px
Start display at page:

Download "IT solutions. News 2003 Additions to the IT Catalogue"

Transcription

1 IT solutions News 2003 Additions to the IT Catalogue R

2 Looking for success? We offer fresh power Rittal IT solutions: Worthwhile innovations For all segments of the IT market, Rittal offers fresh opportunities with enhanced customer benefits, by serving new markets, securing future options and minimising the risk of plant downtime. Benefits which are really worthwhile. This is the philosophy behind Rittal s innovative strength. New concepts, new application areas, new opportunities For the booming market of interactive terminal systems: Complete, ready-to-use packages for POI and POS applications in the indoor and outdoor sectors. From page 44. Minimising operating costs through security management CMC-TC: Never before has rack security been so individual, simple and cost-effective! Individual, holistic security concepts are achieved quickly and easily via system modules for access control, climate control and power distribution. From page 28. flexrack (i) : New range of benefits, flexible use, lower costs The system enclosure for easy integration of cable management, innovative power distribution and water-based climate control in the frame section, without loss of enclosure volume. For high-performance computer systems. From page 8. Rittal IT News 2003

3 Direct solutions Network enclosures based on Rittal TS 8, pre-configured Network enclosures based on Rittal flexrack (i), pre-configured Server enclosures based on Rittal flexrack (i), 1000 mm deep, pre-configured Networking Network/electronic enclosures based on Rittal flexrack (i) Servers Server enclosures based on Rittal QuickRack, 1000 mm deep Telecommunications RNC enclosure TelcoBox Accessories for TelcoBox Slim-Box rack-mounted system, 1 U 4 U for CPCI CS Toptec IT controlling Security management with Rittal CMC-TC Concept-based risk minimisation Sensor units CMC-TC Processing unit monitoring system CMC-TC Master monitoring system CMC-TC Accessories for the CMC-TC system Speed regulated/controlled fan system Interactive terminal systems Overview of ITS systems ITS Opti-Line II ITS Opti-Desk ITS Opti-Wall ITS Alpha-Line ITS Arc-Line ITS Out-Line Pro Accessories for ITS Outstanding value for money New pre-configured solutions for the server and network enclosure sector. Available off-the-shelf and ready to use. This cuts order and delivery times, whilst also saving assembly work and warehousing costs. From page 10. Accessories Power System Rack Accessories for flexrack (i) /TS Monitor/keyboard unit, 1 U General accessories Rittal IT News

4 Our achievements are your advantages The Rittal value-added package In choosing Rittal, you are making the right decision. We meet all your requirements in terms of flexibility, security, cost-cutting and problem-solving expertise. Everything is spot-on: the platform, the range, the timing, the planning, the quality and the security. Solution diversity through system platforms Our successful platform strategy forms the basis for our comprehensive standard range. Perfect solutions for various applications and to suit individual customer requirements are configured costeffectively from mass production. Pre-configuration saves time Need a solution fast? The IT solutions immediate delivery range offers practical, pre-assembled configurations. This cuts assembly and ordering time, as well as saving warehousing costs. Complete, thanks to system integration You tell us your requirements, and we supply you with an complete individual solution, e.g. with co-ordinated climate control, power supply and security management up to system integration Level 4. All from Rittal, all from a single source. Global proximity with a local presence We translate our experience in international markets into holistic customer solutions. The same goes for your market. 4 Rittal IT News 2003

5 Secure your competitive lead with a quality advantage International approvals and our own accredited laboratories the result? A guaranteed standard of quality available to customers worldwide. Perfect solutions through planning expertise Rittal s expert advisers know their stuff be it EMC protection, earthquake protection, climate control or electronic components, all technical questions relating to a customer s specific requirements are expertly answered. Eliminate the risks with a security advantage Cut operating costs and administration, and ensure simple monitoring of all security-relevant parameters with comprehensive rack security concepts: climate control, power management, access control. Switch to perfection Benefit from our product portfolio Rittal offers a wide range of specialist solutions available off-the-shelf for immediate delivery, for all segments of the IT industry. Further details can be found in our IT Catalogue. Rittal IT News

6 Power System Rack PSR The system rack of the future Create more scope for your core competencies. The Power System Rack PSR is the key. Thanks to total system integration, the rack becomes a functional unit for the installed equipment: In the frame section, without loss of enclosure volume, integral cable management, power management and water cooling supply. Complete plug & play installation ensures easier servicing and installation work, even with the sytem operational, whilst at the same time cutting operating costs. Power management with the plug & play compatibility system Power supply integrated into the frame section without loss of enclosure volume. Minimisation of operating costs by retro-fitting whilst the system is operational. Reduction of installation costs based on the plug & play principle. 3-phase power infeed, additional infeed via the UPS is also supported. Up to 42 slots per 2 m section height. Combined configuration is no problem (e.g. earthing-pin and IEC connectors). Complete contact hazard protection and a high level of operational reliability, thanks to individual fusing. Short cable routes, thanks to flexible module positioning. Cable management included With no additional costs, no loss of volume and fast, flexible assembly. Cost cutting, thanks to effective space utilisation and clip-in cable management modules. Height-variable mounting allows flexible laying of the cables. The supporting enclosure section offers a variety of different cabling options, such as the twin-level concept. 6

7 High performance with liquid cooling The cost-effective, reliable way to achieve a significant increase in the output of your highperformance computer systems. Fluid distribution integrated into the frame section. Direct, effective cooling at the heat source (CPUs, transformers, drives). Fully modular assembly. Supply lines in cable format and drip-free quick-release couplings ensure a high level of operational reliability, simple handling, and connection/disconnection on demand. A recooling system cost-effectively supplies the required cooling fluid. 7

8 You want more performance flexrack (i) : Look to the future and cut costs with Rittal power The new flexrack (i) generation offers an incredibly broad spectrum of benefits: Innovative cable management facilities Integral systems for water cooling supply and power Whether in the office, computer centre, network sector or for server applications, the flexrack (i) is the ideal combination of design and function, aesthetics and ergonomics. That s the flexrack (i). management in the frame section without loss of enclosure volume Ideas for optimum use of the internal enclosure volume Inspiration for a complete plug & play system tailored to customer requirements The design: Innovative, flexible, powerful Very stable multi-functional profile with system duct for cabling, power supply and water cooling supply. Enclosure system may be dismantled because the vertical sections are screw-fastened to the roof and base frame. Vertical variability thanks to infinitely variable attachment on the flexrack (i). Complete compatibility with existing system accessories. Pole position in every time for flexrack (i) For servers and electronics with a width of 600 mm. At the front, the enclosure and mm (19 ) section form a solid line. The rear mounting level is a depth-variable mm (19 ) support frame. This achieves an optimum installation depth. For the network sector and for multi-functional solutions with a width of 800 mm. The new mm (19 ) support system offers maximum stability and flexibility in interior installation. For high-performance computer systems, e.g. with water cooling supply or new power supply and distribution concept. The hollow chamber section may be used for cable management. 8 Rittal IT News 2003

9 Individual requirements solved The complete range of enclosures, from the smallest applications through to complex computer centres, offers the ultimate in flexibility, providing a platform for the most diverse applications. Ideal for a growing network, because it is bayable and stackable. Integral cable management (vertically in the frame section, horizontally via the rear door spacing using adaptors). Rittal IT News

10 Network enclosure Front view, glazed door Network enclosure Front view, glazed door, vented Network enclosure Rear views Server enclosure Front/rear view B B 425 A A H 2102 H a Other pre-configured variants in the most practical sizes are available ex-stock. Network/server enclosures, 800 mm wide, pre-configured Server enclosures, 600 mm wide, pre-configured U Width (B) mm Height (H) mm Depth (T) mm Model No. DK including two plug-in side panels, with security lock 3524 E Model No. DK as bayed enclosure without side panels, network enclosures including baying kit * * * * * * Supply includes Enclosure frame based on TS 8, with inner and outer mounting level Enclosure frame based on TS 8, with outer mounting level 1 glazed door front, frame made from extruded aluminium section, 3 mm single-pane safety glass, comfort handle for semi-cylinder with security lock 3524 E, 180 hinging for stand-alone siting 1 vented glazed door at the front, sheet steel with vent slots and 3 mm single-pane safety glass, comfort handle for semi-cylinder with security lock 3524 E, 180 hinging for stand-alone siting 1 vented sheet steel door front and rear, including comfort handle for semi-cylinders and security lock, 130 hinge 1 rear door made from sheet steel, with swivel handle and security lock 3524 E, 130 hinge for stand-alone siting 1 vented rear door made from sheet steel, with swivel handle and security lock 3524 E, 130 hinge for stand-alone siting 1 roof plate for cable entry at the rear, removable 1 roof plate for cable entry in the corners 1 gland plate at the front, fitted as an infill panel, rear section open 1 one-piece gland plate, vented, with cable entry at the rear Multi-piece gland plate for cable entry with vented base module integrated at the front 1 base/plinth, 100 mm high, vented trim panels for front and rear supplied loose, solid side trim panels fitted mm (19 ) mounting level front and rear Cranked mounting angles L-shaped mounting angles Mounting angles attached to depth stays Mounting angles screw-fastened to installation brackets Earthing of all enclosure panels on the enclosure frame Central earthing point fitted at the rear of the base frame 2 TS punched sections with mounting flanges for network enclosures fitted as a shipping brace on the inner mounting level 4 levelling feet (including base/plinth adaptor), supplied loose 4 spacers, 20 mm, for raising the roof, supplied loose 4 cable clamp rails for use on the inner level in the enclosure depth (width) 10 cable shunting rings made of plastic, 105 x 70 mm, supplied loose 50 captive nuts, M6, conductive, supplied loose 50 Torx screws, M6, with plastic washers, supplied loose * For version in RAL 9005 (deep black), please refer to IT Catalogue 2002, page Rittal IT News 2003

11 Network / server enclosures Based on Rittal TS 8, pre-configured Sheet steel Surface finish: Enclosure frame: Dipcoat primed in RAL 7044 Doors, roof, base/plinth and side panels: Dipcoat primed in RAL 7044 and additionally powdercoated in RAL 7035 Gland plates, punched sections with mounting flanges and mounting angles: Zinc plated, passivated Stabiliser bracket for base/ plinth mounting for added stability, see page 66. Pull-out stabiliser for server enclosures for mounting on the TS 8/FR (i) base frame, see page 67. Server enclosure with vented sheet steel door front and rear. Supports horizontal air routing. Rittal IT News

12 Front view Side view Rear view B T T H 769/969 Roof view Top view (cross-section) Based on the system platform of the new FR (i), this enclosure system offers extensive opportunities for enclosure design. The broad selection of mounting parts and accessories ensure that there are no limits to individual configuration. Optimum space utilisation of the enclosure volume is ensured, thanks to the innovative, multi-functional profile, thereby offering a high degree of flexibility, as well as a high level of investment protection thanks to its modular extendibility. Network enclosures FR (i), pre-configured U Width (B) mm Height (H) mm Depth (T) mm Model No. FR (i) Supply includes 1 multi-platform frame FR (i) 1 designer glazed door front, including 130 hinge, single-point cam lock including security lock 3524 E, may be exchanged for semi-cylinder 1 sheet steel rear door solid, including 130 hinge, with single-point cam lock including security lock 3524 E, may be exchanged for semi-cylinder 2 designer side panels, including security lock 3524 E 1 roof plate, two-piece, for cable entry 1 enclosed roof plate, solid, passive ventilation by raising the roof plate 1 designer base/plinth, vented 1 gland plate, front, fitted as an infill panel, rear section open 1 gland plate, one-piece, vented with cable entry mm (19 ) mounting angles fitted in the front of the enclosure mm (19 ) mounting frame front, fitted with varying depth mm (19 ) mounting frame rear, fitted with varying depth Earthing of all enclosure panels on the enclosure frame Central earthing point mounted on the rear of the base frame 4 hammer-head rails including system adaptor supplied loose, for cable clamping in the enclosure depth 10 cable shunting rings 105 x 70 mm, supplied loose 50 captive nuts and Torx screws supplied loose 1 set of baying clamps supplied loose 4 levelling feet (including base/plinth adaptor), supplied loose 12 Rittal IT News 2003

13 Network enclosures Based on Rittal flexrack (i), pre-configured Vertical frame sections: Extruded aluminium section Base, roof frame, panel: Sheet steel Surface finish: Enclosure panels: Spray finished in RAL 7035 Frame sections, doors: RAL 9006 Lock panels: RAL 7035 Viewing window: Tinted, parasol grey Gland plates, mm (19 ) mounting angles: Zinc-plated, passivated The interchangeable lock panel may also be conveniently exchanged retrospectively for electric lock systems. See page 40. Power management integrated directly into the frame section, three-phase infeed based on the plug & play system, with no loss of enclosure volume. See page 60. The mm (19 ) mounting frame facilitates configuration with particularly heavy loads. See page 66. Rittal IT News

14 Ø 112 Front view without door, with mm (19 ) mounting angles Front view with door B Side view (cross-section) 1050 Rear view with door H Top view cross-section Roof view for FR Roof view for FR T 45 1 = Maximum distance between levels 829 mm Based on the system platform of the new FR (i), this rack meets very high demands in terms of stability, design and system integration. The enclosure depth of 1050 mm provides sufficient space for the installation of standard server types attached to the front mm (19 ) mounting angles and the rear mm (19 ) frame. The mm (19 ) frame is fully depth-variable and therefore ensures flexible installation in the depth. The vented (designer) doors with a free space in the perforated plate section of 64% ensure the required air throughput. The integral, pull-out stabiliser ensures additional safety during maintenance work. The new aluminium section offers additional functions for optimum cable management. Fibre-optic and copper cables may be routed in the frame section of the enclosure. This ensures significantly better handling during cable management. What is more, the FR (i) aluminium section offers additional opportunities for system integration such as the accommodation of power management and/or liquid cooling components. FR (i) server enclosures, pre-configured U Width (W) mm Height (H) mm Depth (T) mm Model No. FR (i) Supply includes 1 system frame section FR (i) * 1 designer door at the front, vented, 1 sheet steel door at the rear, vented, with 130 hinges, with free surface in the perforated plate section of 64%, with single-point cam lock including security lock 3524 E, may be exchanged for semi-cylinder 1 roof plate, solid 1 roof plate with cable entry openings in the corners 1 pair of mm (19 ) mounting angles, front, attached to the frame mm (19 ) frame at the rear, infinitely depth-variable Earthing of all enclosure panels via the enclosure frame to VDE central earthing point mounted on the rear of the base frame 4 levelling feet 1 stabiliser with 2 integral levelling feet, integrated into the base frame Accessories 2 designer side panels with beading, including security lock 3524 E Transport kit, 4 castors including assembly parts * The system frame FR (i) is generally suitable for the installation of TS 8 accessories. For further accessories, please refer to IT Catalogue under Server integration (page 106 onwards) and TS 8 accessories (page 348 onwards). 14 Rittal IT News 2003

15 Server enclosures Based on Rittal flexrack (i), 1050 mm deep, pre-configured Vertical frame sections: Extruded aluminium section Roof/base frame, panels: Sheet steel Surface finish: Enclosure panels/door trim panel: Spray finished in RAL 7035 Frame sections, perforated plate of door: RAL mm (19 ) mounting angles: Zinc plated, passivated The new designer door combines function with aesthetics. Robust mm (19 ) mounting frame. Integral stabiliser for optimum operational safety. Rittal IT News

16 Front view Side view Rear view B T T H Roof view Top view (cross-section) The benefits of various system platforms form the basis for the new FR (i) frame sections and their multifunctional applications. The optional integration of vertical system adaptors facilitates perfect adaptation and hence enables the use of additional installation potential within the extensive range of Rittal accessories. The new hollow chamber profiles of the FR (i) generation additionally support convenient cable routing, as well as the integration of power management and intelligent climate control within the frame section itself. Supply includes 1 multi-platform frame FR (i) 1 designer glazed door front, including 130 hinge, single-point cam lock including security lock 3524 E, may be exchanged for semi-cylinder 1 sheet steel rear door solid, including 130 hinge, single-point cam lock including security lock 3524 E, may be exchanged for semi-cylinder 1 roof plate, solid, enclosed roof plate up to 1200 mm enclosure height Multi-piece gland plate, slide-mounted in the base frame for cable entry 4 levelling feet supplied loose U Width (B) mm Height (H) mm Depth (T) mm Model No. FR (i) Rittal IT News 2003

17 Network / electronic enclosures Based on Rittal flexrack (i) Vertical frame sections: Extruded aluminium section Base, roof frame, panels: Sheet steel Surface finish: Enclosure panels: Spray finished in RAL 7035 Frame sections: RAL 9006 Lock panel: RAL 7035 Viewing window: Tinted, parasol grey Gland plates: Zinc plated, passivated mm (19 ) mounting angles for front installation with electronic components and subracks. Cables may be routed and system accessories integrated within the hollow chamber of the frame section. Accessory components may be attached both to the frame section and between the mm (19 ) mounting frames. Rittal IT News

18 Front view Side view Rear view (1242) Cross-sectional view from below Cross-sectional view from above approx With the new enclosure depth of 1000 mm, the server enclosure based on QuickRack offers plenty of space for installing most standard server types with mm (19 ) front and rear attachment. Other installation options may be achieved with the universal server installation kit from our range of accessories. This server enclosure offers a high level of stability and load capacity but is nevertheless easily transported, thanks to the integral mobile base on castors with pull-out stabilisers, coupled with the fact that its overall height is less than 2 m. The new sheet steel doors with full-surface ventilation and free space in the perforated plate section of 64% ensure optimum ventilation of the servers. The modular configuration of the roof and base frame support solutions adapted to suit every required application. Interior installation of the server enclosure is via fully depthvariable attachment of the two mm (19 ) levels or by various component shelves. The side panels (see table below) are plugtype and have a security lock. Server enclosures QR, 1000 mm deep U Width mm Height mm Depth mm Model No. QR Supply includes QuickRack server enclosure, with firmly linked frame Front and rear door made from sheet steel, vented area 64% with 130 hinges 1 roof frame for module panels 1 base frame for module panels 6 levelling feet for stability, mounted on the built-in base/plinth 4 transport castors, pre-integrated into the base/plinth 1 pull-out stabiliser, integrated into the base/plinth at the front 2 pairs of mm (19 ) mounting angles, mounted depth-variably at the front and rear on 2 depth stays each side 2 pairs of mm (19 ) mounting angles, mounted depth-variably at the front and rear on 3 depth stays each side Accessories Side panels with security lock, spray finished in RAL 7035 (packs of 2) Module panel*, solid, 450 x 650 mm for roof frame Slide rail 1 U, depth-variable within the range from mm, load capacity 80 kg Component shelf mounting kit, heavy-duty, load capacity 100 kg Heavy-duty component shelf for mounting kit, RAL 7035, 500 mm deep Heavy-duty component shelf for mounting kit, RAL 7035, 700 mm deep cable clamp rails for the enclosure depth, for cable routing with cable ties combination rails for the enclosure width, for cable clamping with cable ties or clamps Ergoform-S handle for semi-cylinder, to replace the existing handle system Lock insert for Ergoform-S, lock 3524 E with 2 keys Baying kit Complete earthing kit for QR * Module plate combinations, see IT Catalogue, page 422 Recommended accessories: Universal server installation kit, see IT Catalogue pages 467 and 418 onwards. 18 Rittal IT News 2003

19 Server enclosures Based on Rittal QuickRack, 1000 mm deep Enclosure: Sheet steel, spray finished Mounting angles, depth stays: Sheet steel, zinc plated, passivated Colour: RAL 7035 Modular roof configuration with module plates for active and passive ventilation and for cable entry. Mobile base on castors with integral, pull-out stabiliser and levelling feet for stability. Upon request, own locks with semi-cyclinders may be replaced by Ergoform-S handle QR Rittal IT News

20 A A Without side panel Structures for ADSL, the smart solution for office environments... The ideal rack to accommodate telecommunications equipment for ADSL technology, consisting of a splitter (BBAE), modem (NTBBA), optional router and/or ISDN telephone technology, consisting of a network terminator basic access (NTBA) and optional telephone system. Just as it should be: Every device has its designated place. All cables are laid in a structured way. Every connector is easily accessible. Options for extensions are provided. Unrestricted mobility with location changes. A smart design which is at home in any modern office environment. Rittal sets new levels in multi-media applications for the small office/home office sector! The RNC TelcoBox is the central junction for communications via ISDN and/ or ADSL in small networks. TelcoBox Design 42 HP ( 1 / 2 19 ) U 6 Width mm 342 Height mm 390 Depth mm 350 Model No. DK Page Supply includes 1 component shelf 3 mounting plates, slotted, for equipment attachment and cable management Cable entry in the base and rear panel, covered with brush strip Vent slots for passive climate control in the side panels Glazed door, tinted, lockable Rear panel, removable, with quick-release fastener Assembly parts for installed equipment Accessories Model No. DK 3-way socket strip way socket strip with switch Component shelf for static installation, 1 U, 42 HP ( 1 / 2 19 ) Wall console Base/plinth with levelling feet and cable clamp strap Cable management panel 1 U, 42 HP ( 1 / 2 19 ) Rittal IT News 2003

21 RNC enclosure TelcoBox The new RNC TelcoBox combines: Broadband technology (ADSL) Telephone systems and distribution Routing Small ISDN systems Structured cabling Sheet steel/aluminium, spray finished Acrylic glazing, tinted Colour: Enclosure panels: RAL 7035 Corner sections: RAL 7030 With component shelf to accommodate e.g. a telephone system; with vent slots for optimum climate control. With slotted mounting plates for equipment attachment and cable management. With 6 U mm ( 1 / 2 19 ) level for the installation of patch panels etc. Rittal IT News

22 Accessories for TelcoBox Base/plinth, 60 mm high To accommodate a maximum of 2 socket strips and as a cable storing space. Sheet steel Colour: RAL 7035 Supply includes: Base/plinth, levelling feet, cable clamp strap. Base/plinth for TelcoBox Model No. Width mm Depth mm DK Console for wall mounting System-compatible wall bracket, with space for optimum cable routing in the wall area. Sheet steel Colour: RAL 7035 Supply includes: Console, assembly parts. Wall console for TelcoBox Model No. Width mm Depth mm DK Rittal IT News 2003

23 Accessories for TelcoBox Component shelf 1 U, 42 HP mm ( 1 / 2 19 ), static installation For mounting on a pair of mm ( 1 / 2 19 ) mounting angles. The 140 mm deep component shelf is the ideal support surface for small active components such as modems or mini-hubs. Sheet steel Colour: RAL 7035 Depth mm Packs of Model No. DK Cable management panel 1 U, 42 HP mm ( 1 / 2 19 ) For optimum horizontal cable routing, with tray and 5 routing lugs. Sheet steel Colour: RAL 7035 Packs of Model No. DK way socket strip (without switch) The socket strip can be mounted in the base/plinth and on the frame of RNC enclosures. The arrangement of the sockets at a 45 angle allows unrestricted use of angular connectors. Technical specifications: Rated voltage: 250 V Rated current: 16 A Connection cable: 2 m, grey, without connector, H05VV-F3G1.5 Dimensions L x W x H: x 44.2 x 44 mm DIN Aluminium section, natural anodised, polycarbonate sockets. Supply includes: Socket strip, 2 angle brackets, assembly parts. Model No. DK way socket strip (with switch) For mounting on the frame of RNC enclosures (base/plinth mounting is not possible), illuminated, 2-pole switch, safety bars prevent unintentional contact. Technical specifications: Design as above, except dimensions L x W x H: x 44.2 x 44 mm Model No. DK Rittal IT News

24 Technical specifications, 1 U and 2 U: 1 or 2 U rack-mounted enclosures with mm (19 ) mounting brackets (offset by approximately 100 mm to the rear) 2 or 4 slots for CPCI cards at the front and rear Enclosure cooling from left to right EMC and ESD-compatible design Integral Monolithic CPCI backplane 64 bits/66 MHz with H.110 bus on J4 Mains input module Including fan: for 1 U: 12 V DC, 21 m 3 /h, for 2 U: 12 V DC, 74 m 3 /h Optional: Hot-swap-compatible power supplies with current splitting for redundant operation (2 U) Other versions available on request Conforms to IEEE /10/11, CompactPCI Spec. 2.0 Technical specifications, 3 U and 4 U: 3 or 4 U rack-mounted enclosures with mm (19 ) mounting brackets (offset by approximately 100 mm to the rear) 6 or 8 slots for CPCI cards at the front and rear Enclosure cooling from left to right EMC and ESD-compatible design Integral Monolithic CPCI backplane 64 bits/33 MHz with H.110 bus on J4 Mains input module Including fan: for 3 U: 12 V DC, 195 m 3 /h or 74 m 3 /h, for 4 U: 12 V DC, 74 m 3 /h Optional: Hot-swap-compatible power supplies with current splitting for redundant operation Other versions available on request Conforms to IEEE /10/11, CompactPCI Spec. 2.0 Slim-Box rack-mounted system 1 U, 2 U, 3 U, 4 U U Depth mm For PCB depth mm front rear Model No. RP MPS system Mechanical supply includes Description Material mm (19 ) rack-mounted enclosure Sheet steel, with front/rear slots for board spray finished with front slots for PSU Guide rails, keyable Polycarbonate Electrical/electronic supply includes Technical specifications Monolithic backplane CPCI 64 bit/66 MHz and H Monolithic backplane CPCI 64 bit/33 MHz and H Mains input module with power switch, line filter and fuse DC fan left see above DC fan right see above Accessories AC power supply 175 W AC power supply 200 W AC power supply 250 W EMC front panel 6 U, 4 HP EMC front panel 6 U, 8 HP EMC front panel 6 U, 12 HP EMC front panel 6 U, 16 HP EMC front panel 3 U, 4 HP EMC front panel 3 U, 8 HP EMC front panel 3 U, 12 HP EMC front panel 3 U, 16 HP H.110, 48 V connection cable Rittal IT News 2003

25 Slim-Box Rack-mounted system 1 U, 2 U, 3 U, 4 U for CPCI Sheet steel, spray finished Power supply 175 W, hot-swap-compatible. Model No. see Electronics catalogue, page 116/117. Monolithic CPCI backplane with H.110 bus (from 2 U). Mains input module Rittal IT News

26 894 (744) (594) A 1600 (1200) 1645 (1245) A 800 (650) 850 (700) (500) 700 (550) Section A A 562 (412) 608 (458) 653 (503) 712 (562) 758 (608) 803 (653) Technical description/supply includes: Outdoor enclosure fully preconfigured. Door front and rear, side panels left and right. Walls and doors doubled on the outside by 25 mm, doors hinged on the right, with Ergoform-S handle and security lock, all-round roof projection, screw-fastened from above with security screws. Roof additionally protected by the door, cannot be removed from the locked enclosure even after loosening the eyebolt. Eyebolts on the roof for transportation by crane may be exchanged for security screws. Side panels vented, inner side panel screw-fastened to the enclosure frame from the outside, outer panel suspended, protected against dismantling by the roof projection. Base/plinth including two screw-fastened gland plates for cable entry, screwfastened base/plinth trim panels at the front and rear. Design with heat exchanger/cooling unit: Door with integral climate control unit, for technical specifications please refer to CS Outdoor Solutions, page 66. Climate control unit attached to the mounting frame in the door. The mounting frame offers three attachment positions. Supplied as a built-in unit inside the enclosure, minimum exterior projection. The enclosure dimensions correspond to IEC EN CS Toptec Without climate control module With heat exchanger CS With cooling unit CS Model No. CS Width mm Height mm Depth mm Base/plinth height mm Rain canopy height mm Overall height mm Roof projection mm Overall width mm Supply includes 1 enclosure frame Doors front and rear Side panel left and right 1 base/plinth 1 roof For technical specifications please refer to CS Outdoor Solutions, page Rittal IT News 2003

27 Telecommunications CS Toptec Enclosure frame: Stainless steel , 1.5 mm Doors, side panel, base/plinth, roof: Aluminium, AlMg3, 2.0 mm Surface finish: Doors, side panel, base/plinth, roof: Powder coated in RAL 7035 Protection category: IP 55 to EN /10.91 Complies with NEMA 12. Rittal IT News 2003 Depth stays to accommodate metric and mm (19 ) mounting angles, see CS Outdoor Solutions, page 67. TS punched sections with mounting flanges with 5 rows of holes, for variable interior installation, see CS Outdoor Solutions, page 71. Cooling units Air/air heat exchanger and cooling units integrated into the door. For technical specifications, please refer to CS Outdoor Solutions, page

28 IT Controlling Security management with Rittal CMC-TC a success factor Data losses and the failure of networks and production plant can entail enormous cost risks, and even threaten a company s very existence. For this reason, safeguard your company s life blood by ensuring a stable flow of information and secure production flows. As the manufacturer of the world s most comprehensive packaging and climate control ranges, Rittal now unveils the latest generation of monitoring technology: Rittal CMC Top Concept. Individual, simple, cost-effective rack security. Climate control Consistent low temperatures for electronics are a key safety factor in the network and in the production process. Monitoring of the internal rack temperature and the control of climate technology to reliably dissipate heat loss is provided by the Rittal CMC-TC security system to minimise operating costs. Power management Power requirements are on the increase, and there is a growing need for maximum availability of modern IT structures. Rittal addresses the associated additional requirement for redundant power supply with a new, intelligent power distribution system which may be integrated with no loss of enclosure internal volume. 28 Rittal IT News 2003

29 More compatibility The CMC-TC is capable of communicating via virtually all standard protocols. Further information and downloads can be found at: or in the CMC-TC brochure. More profitability The CMC-TC facilitates integration of the decentralised function blocks into your IT system, quickly and without incurring any unnecessary costs. More flexibility The modular layout and almost limitless extendibility means that the CMC-TC grows along with your requirements. More individuality The CMC-TC can be adapted in full to your requirements, from decentralised monitoring via individual processing units, through to control of the complete system by a master unit. Access Control Access authorisation is one of the most important security factors in any company. With the CMC-TC, this is registered for the entire network. In case of an unauthorised access attempt, the system will raise the alarm. For example, doors may be opened by authorised individuals via a numerical code, magnetic card, smartcard, or the latest transponder technology. Rack security Effective prevention, comprehensive security and central organisation of rack security. The new, modular CMC-TC facilitates the implementation of highly individualised security solutions, thanks to its modular plug & play system, and therefore affords a high level of protection for your investment. Rittal IT News

30 Concept-based risk minimisation The security centre Access authorisation With the CMC-TC, this is registered for the entire network. In case of an unauthorised access attempt, the system will raise the alarm. Smartcard readers, magnetic card readers or coded locks are combined with access sensors and electromagnetic locks. All security-related factors in or on an enclosure system or room are permanently monitored by the Rittal CMC-TC, and any potential risks are logged and indicated in good time. Appropriate counteractive action can either be initiated automatically, or by the central remote monitoring facility. Heat High temperatures and temperature fluctuations pose a major threat to modern microelectronics. By controlling the corresponding climate control components, the CMC-TC ensures a constant cool temperature. Any breaches of the limits are reported. Further information can be found in our CMC-TC brochure, available at Smoke Smoke generation always means a risk. The system raises the alarm. Vandalism Reportable: e.g. vibration caused by damage or the impermissible opening of enclosure surfaces. The information is supplied by the relevant sensors. Condensate Humidity causes incorrect flows. The hygro-sensor initiates preventive action via the CMC-TC. Sensor unit I/O unit Access unit Climate unit Sensors/actuators: Temperature sensor Humidity sensor Analog sensor input module ma Access sensor* Vandalism sensor Airflow monitor Smoke alarm Motion sensor Digital input module Digital relay output module Voltage monitor Latch/reader: Elec.-magn. Ergoform-S FR/PS/TC Electro-magnetic Ergoform-S QR Electro-magnetic TS 8 handle Universal latch Relay output module for room door Smart card reader Magnetic card reader Coded lock * Up to a maximum of 5 sensors may be connected in series. Signals Clear indication of danger: decentralised optical alarm signals on the smoke alarm or via signal lamps are provided in addition to centralised reporting via the CMC-TC. With the new CMC-TC system, all monitoring functions and sensors may be freely selected. The CMC-TC system allows users to configure a monitoring application costeffectively and in a targeted manner. The processing unit (PU) with network interface forms the basis. The sensor units are combined with sensors to connect the PU. This determines the function. The PU may optionally be operated via the CMC-TC master to provide superior performance. The package is rounded off by the plug & play concept with automatic sensor detection and configuration. Rittal IT News 2003

31 The sensor units Universal I/O unit The I/O unit is the measurement and alarm module. Alarm sensors may be connected (e.g. motion detector). Analog measurements can be transmitted and monitored (temperature, humidity, 4 20 ma). The system is capable of switching relay output modules. The unit has 4 universal ports for 4 sensors/actuators. The I/O unit must be connected to the PU. Data exchange and energy supply to the electronics are provided in this way. Access unit The access unit serves to control door systems. The doors can be opened remotely via the network. The doors can also be opened by selected individuals via a coded lock, magnetic card or smartcard. The doors of enclosures or rooms can be monitored and activated. The unit is designed for two separate door systems. The access unit must be connected to the PU. Data exchange and power supply to the electronics are provided in this way. Climate unit The climate unit serves to control the fans and hence regulate the temperature. The physical airflow of the fan is monitored with due regard for the controller. If no temperature sensor or airflow sensor is used, the two universal ports can also be fitted with other sensors (see table). Simple fan connection via IEC jacks and connectors. The unit is designed for one fan system. The climate unit must be connected to the PU. Data exchange and power supply to the electronics are provided in this way. Processing unit (PU) The processing unit (PU) forms the basis of the monitoring system. The system can be incorporated directly into the user network via the network interface 10BaseT, TCP/IP, SNMP. The system has an integral web server, through which the system can be configured. The system can optionally be linked to the CMC-TC master via the network interface. The monitoring functions are determined by the sensor units or sensors/actuators linked to the PU, and can therefore be flexibly selected. Up to 4 sensor units may be connected in any given combination (I/O, access, climate). Master unit The CMC-TC master is required in all situations where it is necessary to monitor large numbers of securityrelevant factors or where high demands are placed on the system. The CMC-TC master offers high performance and conserves IP resources. The PU with the sensor units is always required for monitoring. Up to 10 processing units (PUs) may be connected as slaves. The master offers a 10/100BaseT interface to the user network and comprises all monitoring variables on HTTP and SNMP. The system can be connected and operated directly via the Rittal SSC. Rittal IT News

32 There is a choice of 3 sensor units: I/O unit: The alarm and measurement module Access unit: For controlling door systems Climate unit: For fan control and monitoring Benefits: Choice of functions thanks to three sensor units Open to customer-specific sensors/ actuators Automatic sensor detection Simple installation based on the plug & play system No additional power pack required Choice of mounting on the enclosure frame or mm (19 ) mounting angles I/O unit: Freely selectable sensors/actuators Access unit: Personalised access detection Climate unit: Fan control with airflow monitoring Technical specifications: The sensors/actuators are set up via an automatic electronic ID system. Because it is installed using a flexible plug & play system, there is no need for time-consuming programming and wiring. Power is supplied centrally via the connection cable to the PU. Technical specifications: W x H x D: 136 mm x 44 mm (1 U) x 129 mm Temperature application range: +5 C to +45 C Humidity application range: 5% to 95% relative humidity, non-condensing IP protection category: IP 40 to EN CMC-TC sensor unit I/O unit This sensor unit allows alarm messages, status messages and measurements to be forwarded or remote actions to be executed via relay output modules. The I/O unit has 4 universal inputs/outputs. The sensors/actuators listed below can be operated here. The interface to the user network is via the PU (processing unit), which is always required to operate the system. C CMC-TC I/O unit I/O Interface for the sensor unit and processing unit connection. Used for data communication and power supply. Cable /.472 /.481. Just one press of the button, and the system automatically reconfigures itself. ➀ Control key for detection/set-up of the sensors/actuators ➁ Alarm LED signals alarms or configuration changes ➂ Mounting fixture for or ➀ RJ 12, 4 inputs for sensors/ actuators (see bottom list) ➁ RJ 45, connection to PU via connection cable /.472 /.481 (The unit is also supplied with power via this connection.) Sensor unit I/O unit Model No. DK 4 universal inputs or outputs Also required: Up to 3 systems may be integrated into the 1 U mounting unit: Model No Sensors/actuators max. Model No. DK Temperature sensor Humidity sensor Analog sensor input module 4 20 ma Access sensor* serial Vandalism sensor Airflow monitor Smoke alarm Motion sensor Digital input module Digital relay output module Voltage monitor * Up to a maximum of 5 sensors may be connected in series. 32 Rittal IT News 2003

33 CMC-TC sensor unit access unit CMC-TC sensor unit climate unit Sensor units CMC-Top Concept With this sensor unit, one or two doors may be released for access via the network, or personalised opening via a read system (e.g. smartcard reader) may be initiated. The system also monitors the status of the door, handle or latch. Authorised access codes can be set up via http. The sensors/actuators/readers listed below can be operated here. In order to operate the unit, at least one access sensor and at least one latch (e.g. handle) per door system must always be used. See below. A temperature control circuit is installed with this sensor unit. Temperature setpoints are set via the PU, and these are compared with the actual temperature. Depending on the evaluation, the fan system is activated. The function of the fans can also be monitored with an airflow sensor. Monitoring is only active whilst the fan is operational. Other sensors may optionally be connected to the unit. In order to operate the unit as a temperature fan control circuit, at least one temperature sensor must always be used. See below. C CMC-TC Access unit 1 2 C CMC-TC Climate unit ➀ Control key for detection/set-up of the sensors/actuators ➁ Alarm LED signals alarms or configuration changes ➂ Mounting fixture for or ➀ Inputs for access sensor, latch system 1 (see bottom list) ➁ Inputs for access sensor, latch system 2 (see bottom list) ➂ I 2 C bus for reader units, door system 1 and 2 (see bottom list) ➃ RJ 45 connection to PU via connection cable /.472 /.481 (The unit is also supplied with power via this connection.) ➀ Control key for detection/set-up of the sensors ➁ Alarm LED signals alarms or configuration changes ➂ Mounting fixture for or ➀ Input for fan supply 115/230 V AC, cable ➁ Output to fan with cable ➂ RJ 12, 2 inputs for sensors (see bottom list) ➃ RJ 45 connection to PU via connection cable /.472 /.481 (The unit is also supplied with power via this connection.) Sensor unit access unit Model No. DK Control of 2 door systems Sensor unit climate unit Model No. DK Control of a fan system Also required: Sensors/actuators max. Model No. DK Access sensor* 2 +2 serial Digital input module for door release Latch/reader Electro-magnetic Ergoform-S FR/PS/TC Electro-magnetic Ergoform-S QR Electro-magnetic TS 8 handle Universal latch Digital relay output module for room door Smartcard reader for door release Magnetic card reader for door release Coded lock for door release * Up to a maximum of 5 sensors may be connected in series. Also required: Sensors max. Model No. DK Temperature sensor Access sensor* 2 +2 serial Airflow monitor Smoke alarm Motion sensor Digital input module Voltage monitor * Up to a maximum of 5 sensors may be connected in series. Rittal IT News

34 C IOIOI CMC-TC Processing unit Control key The control key is used for sensor/actuator detection, set-up of the system and acknowledgement. Alarm LED The LED signals alarms or configuration changes. Link/Traffic LED The LED indicates the status of the 10BaseT network interface. RS 232 interface RJ 11 For programming via a serial PC interface LEDs channels of sensor units The LEDs indicate the status of the connected sensor units. Acoustic alarm There is an acoustic alarm signalling device integrated into the PU. Mounting attachment For attachment with nylon tape, individual bracket or 1 U mounting units P-I 2 C 3 4 IOIOI Power 24 VDC max. 2 A Inputs for the RJ 45 sensor units Up to 4 sensor units may be connected to the PU via the 4 inputs. The sensor units determine the function of the PU. There is a choice of 3 sensor units. Connection cable /.472 /.481. Power I 2 C bus RJ 45 Up to 2 voltage extension units may be connected via the power I 2 C bus. Up to three AC voltages may be monitored with every extension unit. Connection cable /.472 / Alarm relay RJ 12/ RS 232 RJ 12 The upper RJ 12 jack provides a change-over contact for the PU alarm relay. Connection cable The lower RJ 12 jack provides a serial interface (display unit/gsm module). Ethernet 10BaseT RJ 45 Integral Ethernet interface to IEEE via 10BaseT half-duplex 10 MBit/s. Voltage supply The rated voltage for the PU is 24 V DC. There is a choice of power packs with varying primary voltages. AC power pack CMC-TC processing unit (PU) The processing unit forms the basis of the CMC-TC system. This unit is required for every monitoring application. Interface to the customer: The PU can be incorporated directly into the user network via 10BaseT. The PU can also be linked to the master via this interface (TCP/IP, SNMP). Interface to the sensors/actuators: The PU provides 4 open ports for sensor units. The sensor units determine the function of the PU. There is a choice of 3 different sensor units (I/O, access, climate) with varying functions. In this way, the monitoring functions may be freely combined. Fast, easy programming and installation: The sensors/actuators are set up via an automatic electronic ID system. Installation is via a flexible plug & play system. This eliminates the need for timeconsuming programming and wiring. Power supply: Power is supplied centrally via a power pack in the PU. The connected sensor units and all connected sensors are supplied with power in this way. There is a choice of two input voltages (AC power pack and DC power pack ). Technical specifications W x H x D mm 136 x 44 (1 U) x 129 Rated voltage 24 V DC Network interface Ethernet to IEEE via 10BaseT half-duplex 10 Mbit/s Protocols TCP/IP, SNMP V1.0, TELNET, FTP, HTTP Serial interfaces RS 232 Ports for sensor units 4 jacks RJ 45, shielded Bus system Power I 2 C for extension unit voltage AC Relay output module Change-over contact max. 24 V DC 1 A Acoustic display Piezo signal generator Time function Real-time clock Temperature application range +5 C to +45 C Humidity application range 5% to 95% relative humidity, non-condensing IP protection category IP 40 to EN Ethernet TCP/IP SNMP monitoring system CMC-TC processing unit (PU) Model No. DK Also required: For selection aid, see CMC-Top Concept brochure, page 7, Rittal IT News 2003

35 Monitoring system processing unit CMC-Top Concept Benefits Freely selectable monitoring functions Sensor/actuator ports extendible Network connection TCP/IP SNMP Integral web server for configuration Automatic menu generation Simple installation based on the plug & play system Alarm continues to record even in the event of a network failure Built-in real-time clock May be used via power supply unit for 115/230 V AC or 48 V DC Choice of mounting on the enclosure frame or mm (19 ) mounting angles The protocol for the master/ slave system is TCP/IP SNMP May be used for large computer centres or small individual applications The web server integrated into the PU indicates the status of the 4 sensor units with the connected sensors. The web server integrated into the PU automatically generates the graphical interface for configuring the sensors/ actuators. Links may also be created between the inputs and outputs. The web server integrated into the PU stores the alarm messages independently of the network. These can also be retrieved retrospectively via FTP or HTTP. Rittal IT News

36 CMC-TC Master Key Offset system reset key with contact hazard protection. Input for microphone 3.5 mm jack. Speaker output 3.5 mm jack. 4 5 Status LEDs LED 1 Alarm Alarm system message. LED 2 changeover 10/100 Mbit/s, network interface user network. LED 3 Link/Activity, network interface user network. LEDs for the 10 network inputs of the processing units IrDA Infrared interface. RJ 11 RS 232 interface for CMC-TC menu program. Acoustic alarm There is an acoustic alarm signalling device integrated into the master Voltage supply The IEC jack serves to supply the system Connection cable to.214. Alarm relay RJ 12 socket with changeover contact. Keyboard/mouse PS2 jacks for keyboard and mouse. RS 232 Two serial D-SUB 9 interfaces VGA interface HD15 Connection for monitor or Rittal SSC. USB interfaces Standard 1.1, for applications with Rittal camera. Ethernet 10/100BaseT RJ 45 jack network interface, user network Ethernet 10BaseT/100BaseT, IEEE (10/100 Mbit/s), TCP/IP. 8 9 Ethernet 10BaseT (internal) Ten RJ 45 jacks, network inputs for the processing units Ethernet 10BaseT, IEEE (10 Mbit/s), TCP/IP. PCMCIA Two PCMCIA ports for applications with the Rittal modem. CMC-TC master The master system may be connected between the processing unit and the user network. There are ten 10BaseT network inputs available for the processing units (PU). The PUs transmit all monitoringrelated data and messages to the master system via TCP/IP, SNMP. The master has a 10BaseT/100BaseT network interface for the user network. All monitoring data is provided in a separate MIB via TCP/IP, SNMP. The system may optionally be configured remotely, via the integral web server, or directly, via a local console. Basic settings can also be implemented serially via RS 232 or Telnet. A Telnet routing function to the individual processing units is also pre-integrated. This provides the user with a clear central monitoring facility. For example, up to 160 temperatures may be accessed or up to 80 enclosure doors may be monitored and activated via one IP address. Combined applications are also possible, and may be compiled individually from processing units and sensor units. Further functional scope for the CMC-TC master is available on request in the form of a software update. Technical specifications H x D mm 1 U x 200 Rated voltage V AC 50/60 Hz Network interface Ethernet to IEEE via 10BaseT/100BaseT, 10/100 Mbit/s Protocols TCP/IP, SNMP V1.0, TELNET, SSH, TFTP, HTTP Ports for processing unit 10 jacks RJ 45, shielded, 10BaseT, TCP/IP, SNMP Serial interfaces RJ 11 jack RS 232 menu program, 2 D-SUB 9 jacks RS 232 USB Standard 1.1 for Rittal web cameras Infrared interface IrDA 1.0 (SIR) on the front PCMCIA 2 x type I/II or 1 x type III for applications with Rittal modem Relay output module Change-over contact, max. load capacity 24 V DC, 1 A Time function Real-time clock Temperature application range +5 C to +40 C Monitoring system, Model No. master DK CMC-TC master Also required: For selection aid, see CMC-Top Concept brochure, page Rittal IT News 2003

37 Master monitoring system CMC-Top Concept Benefits Centralised administration Network connection 10/100BaseT Central web server for configuration Local administration via PS2/VGA console Logging function for alarm messages Link for USB camera Free function selection for monitoring Ideal for large computer centres Web access via SSL 3.0 Remote administration via SSH The access to the master system via the integral web server can only be achieved via a password and SSL 3.0 or 128 bit encryption. The graphical Web menu interface allows convenient monitoring of the system status. Settings can also be made here. The menu adapts automatically to the monitoring functions being operated. Rittal USB Web camera Highly sensitive areas may be monitored with the Web camera. JPEG data may be saved. Camera available upon request. Rittal IT News

38 Accessories for the CMC-TC system The basic system The processing unit (PU) is the basis of any CMC-TC application. Connectivity is offered by the network interface (10BaseT, TCP/IP, SNMP) which connects directly into the user network or to the CMC-TC master. The following products are required for each CMC-TC application: Connection cable for sensor units Programming cable Processing unit Power pack Processing unit ( ) Power pack V, 50/60 Hz ( ) or Power pack 48 V DC ( ) Connection cable for power pack, country-specific ( ) Connection cable, sensor unit ( /.472 /.481) At least one sensor unit ( /.220 /.230) Programming cable ( ) Up to 4 sensor units Connection cable for power pack Note: CMC-TC configurator The planning tool for the system and the brochure can be found on the Internet at: Model No. DK CMC-TC main products CMC-TC master CMC-TC processing unit CMC-TC I/O unit CMC-TC access unit CMC-TC climate unit Extension unit 3 x voltage V AC Model No. DK Connection cable/power pack Connection cable D/B/F/A Connection cable GB Connection cable CH Connection cable USA/CDN IEC 320 extension CMC-TC power pack 24 V, input V AC CMC-TC power pack 24 V, input 48 V AC Mechanical adaptor Model No. DK for the locking systems Adaptor for reader units VR (Packs of 10) Adaptor for reader units PC (Packs of 10) Adaptor for reader units PS (Packs of 10) Adaptor for reader units TS 8 designer door (Packs of 10) Locking rod PS 2000 mm Locking rod FR 2000 mm Installation kit, PS sheet steel door for U locking* Installation kit, PS glazed steel door for U locking* Installation kit, FR sheet steel door for U locking* Installation kit, FR glazed steel door for U locking* Installation kit, TS 8 sheet steel door for U locking* Installation kit, TS 8 glazed door door for U locking* Installation kit VR for U locking* * U = Universal Programming cable/mounting unit/ Model No. DK connection cable RJ Programming cable CMC-TC 1 U mounting unit CMC-TC individual mounting unit CMC-TC connection cable, sensor unit 0.5 m (Packs of 4) CMC-TC connection cable, sensor unit 2 m (Packs of 4) CMC-TC connection cable, sensor unit 10 m Model No. DK Cable RJ 11/RJ 12/miscellaneous Connection cable 5 m, CMC socket strip RJ 11 (Packs of 4) Connection cable 5 m, alarm relay PU/Master RJ 12 (Packs of 4) Extension cable 5 m, CMC socket strip RJ 11/ RJ 11 (Packs of 4) Connection cable 5 m sensors/actuators RJ 12/RJ 12 (Packs of 4) Interference-suppression capacitors (Packs of 20) Note: The Model No s. for the sensors, actuators and locking systems can be found directly with the sensor units on page Rittal IT News 2003

39 Accessories for the CMC-TC system CMC-TC display unit GSM unit for CMC-TC For the local representation of CMC alarm and status messages on the rack. The CMC-TC display unit is designed for connection to processing unit It comprises 2 lines each with 20 characters. The character height is 3 mm. The display is illuminated in order to ensure legibility even in poor light conditions. It is mounted in the 1 U component support or with the individual mounting unit Power supply is via the processing unit. The display is also ideal for use as a service tool for commissioning. Technical specifications: Plug & play installation via RJ 12 connector 2 x 20 characters Character height 3 mm Illuminated Supply includes: CMC-TC display module, connection cable for connection to the processing unit, instructions, assembly parts. Also required: CMC processing unit , see CMC-Top Concept brochure, page 12. In order to configure a redundant transmission channel or if there is no network infrastructure available, the unit may be used for alarm forwarding. The alarm signal is designed in SMS format. The GSM unit is linked to the processing unit via a serial interface. The power supply is likewise achieved via the connection cable. The only other thing needed to operate the module is a SIM card. This may either be a data only card or a conventional SIM card. The GSM unit operates in the 900/ 1800 MHz frequency range in other words GSM network cards may be used. Up to four target call numbers may be set and allocated to the various events. To activate CMC-TC switch outputs, an SMS message may be sent to the modem via any commercially available mobile phone, and actions executed via this route. The aerial is contained in the system. Power supply is via the processing unit. Other functions, where offered by the provider: Fax Voice mail CMC-TC Display C Power 24 VDC max. 2 A C CMC-TC GSM Modul Power 24 VDC max. 2 A ➀ LCD display, illuminated 2 x 20 characters ➁ Change /selection ➂ Enter to confirm ➃ Clear to delete/ acknowledge ➀ RJ 12 jack for connection to the serial interface of the PU ➁ The display may optionally be supplied with 24 V DC, 150 ma via this input. When used with the PU, this is not necessary. ➀ Clear to acknowledge ➁ Alarm LED ➀ SIM card rack mount ➁ Aerial system ➂ RJ 12 jack for connection to the serial interface of the PU ➃ The GSM unit may optionally be supplied with 24 V DC, 500 ma via this input. For applications with the PU this is not necessary. CMC-TC display unit Model No. DK Alarm text display Note: Note only one Display unit or one GSM unit, may be connected to one PU. GSM unit Model No. DK SMS function Note: Note only one GSM unit or one Display unit, may be connected to one PU. Also required: Components Model No. DK Processing unit A commercially available SIM card for GSM networks must be provided by the customer. Rittal IT News

40 Accessories for the CMC-TC system Voltage monitor with IEC switch output This sensor is used in conjunction with the CMC-TC to monitor voltage limits. These limits may be configured via the web interface or SNMP. As an additional option, this voltage may also be switched on and off via the module in order to reboot the connected equipment via Ethernet. It is connected via standard, commercially available IEC320 connectors as the input signal, and an IEC320 socket to connect the equipment. Technical specifications: Plug & play installation via IEC320 connector The switching operation may be initiated in a time- or event-based manner or via SNMP or WEB The maximum and minimum limits of voltage measurement are freely selectable Measurement range V AC, 50/60 Hz Max. switching load 250 V AC and 8 A at cos phi = 1 Supply includes: Sensor module, sensor cable for connection to the CMC, assembly parts. Model No. DK Voltage monitor Also required: Model No. DK CMC I/O unit Optionally available: IEC connection cable , German version, IEC extension cable for connecting the equipment. To fit sensor unit: I/O unit Access unit Climate unit Access door panels for FR (i) The access door panels contain an electromagnetic lock with a security lock. They may be exchanged for the existing trim panel of the FR (i) door. The door panel is easily linked to the CMC-TC monitoring system, allowing the FR (i) door to be remotely opened and monitored via the network. If a door trim panel variant with read system is selected, door release may also be implemented via the CMC-TC using the respective medium (smartcard, magnetic card or numerical code pad). The standard door panels of FR (i) doors are easily exchanged for access door panels. There are jacks provided for connection to the CMC-TC. This ensures plug & play exchange. The system may be connected to access unit To operate the system, an access sensor is additionally required. For the door panels with card reader systems, 3 cards are included with the supply. Technical specifications: Rated voltage: 24 V DC Interface: I 2 C Smartcard type: I 2 C chip Magnetic card type: Magnetic strip card with data on track 2. The read system is designed for cards with both a high and a low level of magneticism. Access door panels to exchange for standard trim panels in FR (i) doors Access door Enclosure height Electromagnetic Model No. Read system panel for mm lock system DK FR (i) ➀ FR (i) 2000 Smart card reader FR (i) 2000 Magnetic card reader FR (i) 2000 Coded lock Electromagnetic lock system for the CMC-TC monitoring system. All other height variants (FR (i) enclosure height 600, 1200, 1800 and 2200 mm) are available on request. ➀ The electromagnetic lock system is supplied without panel and can easily be mounted onto the enclosure frame (for FR (i) front and rear doors). 40 Rittal IT News 2003

41 Accessories for the CMC-TC system Handle system for universal installation with electromagnetic locking for the CMC-TC monitoring system The universal handle is equipped with a pitch pattern of mounting holes which will fit many existing door systems. This handle is ideal for retrofitting to projects with varying enclosure types and variants. The new handle may be connected to the CMC-TC system via plug & play. Additionally, an access sensor should always be used to enable polling of the door status. The handle is equipped wtih a connection cable and an RJ 12 connector, which may be plugged into the access unit of the CMC-TC system. The handle is equipped with a push-button insert which may be depressed when the electromagnetic lock is released. Technical specifications: Rated voltage: 24 V DC Rated current: max. 100 ma Connection cable: Length 5 m, RJ 12 connector Dimensions Mounting holes Handle system for TS 8 doors with integral transponder release system from Simons & Voss The electromagnetic TS 8 transponder handle may be retrofitted in the doors of TS 8 enclosures. The handle is equipped with an integral radio transponder solution. The transponder receiver with battery is integrated into the handle housing. Apart from the transponder transmitter, no additional accessories, such as additional electronics, cables, power pack etc., are required. The handle is easily exchanged without the need for wiring. If battery servicing is required, this is indicated acoustically. Door release with hand-held transmitter: The transponder transmitter is actuated from the handle, as a result of which the latter is unlatched for a specified time window and may be opened by pressing the push-button. Door release with the CMC-TC transmitter: The transponder transmitter is linked to the CMC-TC system via the room door output and the access unit. The transmitter is placed in the enclosure frame, near the handle. In this way, the door may be released via the CMC-TC system. Additionally, an access sensor should always be used to enable polling of the door status. Type Model No. DK Electromagnetic handle CMC-TC Extended delivery times. Electromagnetic handle Transponder transmitter Transponder transmitter Type Transponder stand-alone application Hand-held transmitter CMC-TC transmitter Extended delivery times. Model No. DK Benefits: No cables on the handle, because the electronics and battery are integrated into the handle. Several users may be set for one handle. Plug & play installation both mechanical and electrical. Individual control of the transponders and the set-up of each transponder is possible for up to 3 locking systems. With additional overlay to automatically block the old transponder in the event of reprogramming. Counterfeit-proof data communication is achieved via radio using crypto-codes. The challenge response procedure ensures protection against surveillance. The standard interface means that connections to other access and monitoring systems are not a problem. The lock and organisation sytem is graded in the highest category with respect to unlocking protection to BSI Systems with extra electronics and access control from Simons & Voss available on request. Rittal IT News

42 Speed monitored / controlled fan system Rittal Fan Control System FCS and Fan Alarm System FAS The advantages at a glance: Excellent air throughput at a high operating ratio Monitoring of fan speed Plug and play compatibility system Easily installed in Rittal fan roofs Long service life Noise minimisation/speed control Alarm notification via the CMC-TC optionally possible in the network Open supply system 24/48 V DC/ V AC EMC compatibility via DC fan systems Fan 24 V DC with speed control Fan with integral speed control with RJ 12 connector/connection cable 1.5 m for connecting to FCS and FAS Rated voltage: 24 V DC Rated current: 0.28 A (max.) Rated output: 6.72 W (max.) Air throughput (unimpeded air flow): 165 m 3 /h Speed: 2650 rpm Noise level: 41.0 db (A) Note: Fan variant with 48 V DC available on request. Packs of Model No. DK Fan Supply connection cable for FCS/FAS If the customer has access to 24 V or 48 V DC, the FCS/FAS systems may be supplied with power (max. 48 V DC) via the supply connection cable. No power packs are then required for the application. Supply connection cable Model No. DK Rittal IT News 2003

43 Speed monitored / controlled fan system Rittal Fan Control System FCS and Fan Alarm System FAS Fan Control System FCS Speed-monitored fan system The Fan Control System regulates and controls the speed of up to 6 fans , 24 V DC. This helps to save energy and reduce the noise level of the fans, as well as extending the service life of the fans. The failure of one or more fans is detected and notified in the form of a collective fault signal via LED display, beeper and integral alarm relay (floating change-over contact). Control is temperature-based using an external temperature sensor The temperature setpoint is set via a switch on the front. The system may also optionally be set and monitored via the network (Web/SNMP). It is connected directly to the CMC-TC (processing unit) FCS Model No. DK Without fan ➀ Supplied with 24 V/48 V DC via Supply connection cable (direct) CMC 24 V power pack V AC (input) CMC 24 V power pack 48 V DC (input) For operation with 48 V DC, fans with 48 V DC must be used. ➁ RJ 45 jack for connection to the processing unit (optional) ➂ CMC-TC temperature sensor ➃ Alarm relay output 48 V DC, 1 A (floating change-over contact) ➄ Fan with speed control (24 V DC). 48 V DC fans may optionally be used. Note: Supplied pre-configured on request: The FCS system may be fitted in all Rittal fan roofs. Functions: Speed-regulated speed control Fan speed control Optional connection via Web/SNMP Redundant fan control; the air throughput of all fans is automatically increased in the event of a system failure. 5 3 Plug & play installation via RJ 12 connector system mm (19 ) mounting is possible via Fan Alarm System FAS Speed-controlled fan system The Fan Alarm System controls the speed of up to 6 fans , 24 V DC. The failure of one or more fans is detected and notified in the form of a collective fault signal via LED display, beeper and integral alarm relay (floating change-over contact). The system is designed as a plug & play system. The system may also be optionally monitored via the network (Web/SNMP). It is connected directly to the CMC-TC (the I/O unit) FAS Model No. DK Without fan Note: Supplied pre-configured on request: The FAS system may be supplied fitted in all Rittal fan roofs. ➀ Supply with 24 V/48 V DC via Supply connection cable (direct) CMC 24 V power pack V AC (input) CMC 24 V power pack 48 V DC (input) For operation with 48 V DC, fans with 48 V DC must be used. ➁ RJ 12 jack for connection to the I/O unit (optional) ➂ Alarm relay output 48 V DC, 1 A (floating change-over contact) ➃ Fan with speed control (24 V DC). 48 V DC fans may optionally be used. Rittal IT News Functions: Fan speed monitoring Optional connection via Web/SNMP Plug & play installation via RJ 12 connector system mm (19 ) mounting is possible via

44 Information and service anytime, anywhere Interactive Terminal Systems New markets, new application areas, new opportunities! 24 hours a day, terminals are on hand to provide up-to-theminute information, attract interest and receive requests, messages, reservations and orders. Sports, arts, entertainment, administration, transport, industry, trade and hotels suitable applications are everywhere! Located directly at the point where they are needed, offering a high standard of quality and an attractive design, terminals represent valuable partners for information and business. ITS Opti-Line family Elegance, function and aesthetics NEW NEW ITS Opti-Line II A true gem at the point of information whose clear, timeless lines are sure to appeal. Prize-winning! The journal Kiosk Business declared Opti-Line II a winner in the category Best Visual Appeal. See page 46/47 ITS Opti-Desk This elegant stand-up workstation is the ideal tool for all situations where effective advice, information and presentations are needed. See page 48/49 ITS Opti-Wall The attractively styled, spacesaving compact terminal for wall mounting. Ideal for representative indoor applications. See page 50/51 44 Rittal IT News 2003

45 Ready-to-use complete packages Design with distinction Perfection at excellent terms Outdoor terminals including wireless solutions World-wide service NEW ITS Alpha-Line Looking good for interactive communications: Rounded shapes add rhythm and style. See page 52/53 ITS Arc-Line This terminal combines ergonomics with an attractive design. The robust construction ensures stability and also guarantees a high level of protection against vandalism. See page 54/55 ITS Out-Line Pro Multimedia in the outdoor sector: Complete harmony between function and aesthetics. Also available as a radio- and solar-operated variant on request. See page 56/57 Rittal IT News

46 Interactive Terminal Systems ITS Opti-Line II The Opti-Line II creates fresh visions with a tactile appeal. Stainless steel and aluminium, simplicity and elegance, function and aesthetics timeless attributes for successful communication. This is stylish packaging at its most attractive. A keyboard support with new lines, more modularity and a consistent design. A successful innovation from the legendary Opti-Line generation. This is a modular system that meets all requirements, combining flexible selection options with keyboard variants and PC systems depending on the intended application. Optional accessories such as a printer, webcam and coin checker transform this terminal into a veritable multimedia event. Prize-winning! The journal Kiosk Business declared Opti-Line II a winner in the category Best Visual Appeal. ITS Opti-Line II TFT display Contact sensor (touchscreen) including controller Keyboard support for the insertion of ITS keyboards Basic electrical equipment with cabling and power pack for display and sound system ( V, 50/60 Hz) Dimensions of terminal enclosure approximately (W x H x D mm) 560 x 1500 x x 1500 x x 1500 x x 1500 x 560 Model No. ITS Accessories Active sound system including 2 speakers, fitted ITS PC system Silent (for details, see Accessories, page 58) ITS PC system Pro (for details, see Accessories, page 58) ITS PC system Basic PC operating system 2) MS Windows XP Home, German PC operating system 2) MS Windows XP Home, English Long-stroke keyboard with trackball, RAL 9005, German 1)3) Long-stroke keyboard with trackball, RAL 9005, English 1)3) Adaptor plate for internal mounting of the long-stroke keyboard, stainless steel Stainless steel keyboard with trackball, IP 65, German 1) Stainless steel keyboard with trackball, IP 65, English 1) Membrane keyboard with touchpad, German 1) Membrane keyboard with touchpad, English 1) WLAN upgrade kit IEEE type 1 (USB) Mains connection cable, Germany (length approx. 2.5 m) Mains connection cable, UK (length approx. 2.5 m) Mains connection cable, USA/Canada (length approx. 2.5 m) ) Other language variants available on request. 2) Operating system OEM version may only be ordered in conjunction with a PC system; other operating systems available on request. 3) Colour variant RAL 7032, see ITS accessories, page 58/59. Other accessories: ISDN/DSL modems and card readers, coin checkers etc. available on request. 46 Rittal IT News 2003

47 Keyboard: A new design in a smart aluminium cover. No flap, optimum operation. Large flap, easy to service. Display enclosure: Sheet steel, silver grey (RAL 9007), spray finished, smooth Pedestal tubes: Stainless steel V2A, brushed PC case: Sheet steel, silver grey (RAL 9007), spray finished Keyboard support: Aluminium, anodised 47

48 Interactive Terminal Systems ITS Opti-Desk The Opti-Line family with its timeless elegance has been extended to include the Opti-Desk. The Opti-Desk was designed as a stylish stand-up PC workstation for the office environment and for use in the administrative sector. The generous worktop offers plenty of work space, and its successful design blends harmoniously into any environment where effective advice, information and presentations are needed. Customers can choose between two different design variants which differ according to the styling of the front door and the added design elements. The PC keyboard is set flush into the MDF worktop in a space-saving design; the worktop is likewise available in two variants. The PC hardware is housed in the lockable bottom cupboard, where other equipment such as printers, scanners etc. may also be integrated on additional built-in component shelves. The TFT display is housed in a slimline enclosure, together with the speakers. There is a choice of different display sizes. In order to retain mobility with a fully configured business workstation, lockable castors may be optionally retrofitted. Several workstations may be bayed or sited in groups via optional worktops. ITS Opti-Desk TFT display Basic electrical equipment with cabling and power pack for display and sound system ( V, 50/60 Hz) Component shelf mounted in the bottom cupboard Base plate with slides Dimensions with worktop approximately (W x H x D mm) 1000 x 1500 x x 1500 x 800 Dimensions of bottom cupboard with front door only approximately (W x H x D mm) 435 x 1000 x x 1000 x 530 Model No. ITS design variant A (Door and worktop curved inwards, door with horizontal design elements) Model No. ITS design variant B (Door and worktop curved outwards) Accessories Active sound system including 2 speakers, fitted Component shelf for bottom cupboard Set of castors (2 with locks) to exchange for levelling feet ITS PC system Silent (for details, see Accessories, page 58) ITS PC system Pro (1 U, for details, see Accessories, page 58) ITS PC system Basic PC operating system 2) MS Windows XP Home, German 1) PC operating system 2) MS Windows XP Home, English 1) Long-stroke keyboard with trackball, RAL 9005, German 1) Long-stroke keyboard with trackball, RAL 9005, English 1) Adaptor plate for long-stroke keyboard with trackball, RAL Long-stroke keyboard with touchpad, RAL 7035, German 1) Long-stroke keyboard with touchpad, RAL 7035, English 1) Adaptor plate for long-stroke keyboard with touchpad Stainless steel keyboard with trackball, IP 65, German 1) Stainless steel keyboard with trackball, IP 65, English 1) Membrane keyboard with touchpad, German 1) Membrane keyboard with touchpad, English 1) WLAN upgrade kit IEEE type 1 (USB) ) Other language variants available on request. 2) Operating system OEM version may only be ordered in conjunction with a PC system; other operating systems available on request. Further accessories such as DSL/ISDN modem, card reader and coin checker etc. available on request. 48 Rittal IT News 2003

49 Various keyboard variants may be integrated, e.g. in stainless steel. Design line A: The worktop and base plate are harmoniously curved inwards. Design line B: The worktop and base plate are curved outwards, adding a dynamic touch. Sheet steel, spray finished Stainless steel Worktop: MDF Colour: Body: RAL 9006 Front: RAL 9006 Worktop: RAL 9007 Design elements: RAL 9005 Other colour and design variants available on request. 49

50 Interactive Terminal Systems ITS Opti-Wall New compact terminal for wall mounting, based on the successful Opti-Line design. This wall-mounted terminal system, designed for representative indoor applications, is sure to impress, not only with its refined design, but also because of what s inside. Despite the minimal dimensions of this terminal system, there are a range of different configuration variants available. You decide for yourself which TFT, computer power or keyboard you require for your specific application. There is a choice of two PC systems, specifically tailored to the intended application in terminal systems. For example, the Silent PC system ensures a pleasant calm, because the power pack fans normally used in other systems are not required. Above and beyond the accessories listed here, other models (e.g. with magnetic card or smartcard readers) and various colour variants are also available as customer-specific complete systems. ITS Opti-Wall TFT display Contact sensor (touchscreen) including controller Keyboard support for the insertion of ITS keyboards Basic electrical equipment with cabling and power pack for display and sound system ( V, 50/60 Hz) Wall bracket Enclosure dimensions approximately (W x H x D mm) 500 x 950 x x 950 x x 950 x x 950 x 350 Model No. ITS Accessories Active sound system including 2 speakers, fitted ITS PC system Silent (for details, see Accessories, page 58) ITS PC system Pro (for details, see Accessories, page 58) PC operating system 2) MS Windows XP Home, German 1) PC operating system 2) MS Windows XP Home, English 1) Long-stroke keyboard with trackball, RAL 9005, German 1) Long-stroke keyboard with trackball, RAL 9005, English 1) Adaptor plate for long-stroke keyboard, stainless steel (required for the installation of /.310) Stainless steel keyboard with trackball, IP 65, German 1) Stainless steel keyboard with trackball, IP 65, English 1) Membrane keyboard with touchpad, German 1) Membrane keyboard with touchpad, English 1) WLAN upgrade kit IEEE type 1 (USB) Mains connection cable, Germany (length approx. 2.5 m) Mains connection cable, UK (length approx. 2.5 m) Mains connection cable, USA/Canada (length approx. 2.5 m) ) Other language variants available on request. 2) Operating system OEM version may only be ordered in conjunction with a PC system; other operating systems available on request. Further accessories such as DSL/ISDN modem, card reader etc. available on request. 50 Rittal IT News 2003

51 The wall bracket allows easy fixing. The speakers are integrated into the enclosure for protection. Also available as a touch version. Compact, low-noise PC technology: The connections are easily accessible via separate flaps. Sheet steel, spray finished Stainless steel Colour: RAL 9007 (spray finished parts) 51

52 Interactive Terminal Systems ITS Alpha-Line The terminal for tomorrow s world. Here, communication becomes an experience. A journey into the future. This terminal unites two ambitious objectives in a single enclosure: The traditional and the mundane have given way to sleek design. Rounded shapes add rhythm and style, ensuring a powerful impact from any perspective. Pleasantly exciting. Simply unusual. Suitable for the installation of compact and powerful PC systems (Silent and Pro) as well as your choice of keyboard. Navigate your way into the future with a touchscreen or keyboard. A distinctly appealing prospect! ITS Alpha-Line TFT display Contact sensor (touchscreen) including controller Keyboard support for the insertion of ITS keyboards Basic electrical equipment with cabling and power pack for display and sound system ( V, 50/60 Hz) Dimensions including base plate and viewing guard approximately (W x H x D mm) 580 x 1300 x x 1300 x 640 Model No. ITS Accessories Active sound system including 2 speakers, fitted ITS PC system Silent (for details, see Accessories, page 58) ITS PC system Pro (for details, see Accessories, page 58) PC operating system 2) MS Windows XP Home, German 1) PC operating system 2) MS Windows XP Home, English 1) Long-stroke keyboard with trackball, RAL 9005, German 1) Long-stroke keyboard with trackball, RAL 9005, English 1) Adaptor plate for installation of the long-stroke keyboard with trackball, (RAL 9005) Stainless steel keyboard with trackball, IP 65, German 1) Stainless steel keyboard with trackball, IP 65, English 1) Membrane keyboard with touchpad, German 1) Membrane keyboard with touchpad, English 1) WLAN upgrade kit IEEE type 1 (USB) Mains connection cable, Germany (length approx. 2.5 m) Mains connection cable, UK (length approx. 2.5 m) Mains connection cable, USA/Canada (length approx. 2.5 m) ) Other language variants available on request. 2) Operating system OEM version may only be ordered in conjunction with a PC system; other operating systems available on request. Further accessories such as DSL/ISDN modem, card reader, coin checker etc. available on request. 52 Rittal IT News 2003

53 Powerful:The ITS PC systems Silent and Pro. The flap makes servicing work easy. For stability coupled with striking elegance. Inspirational lightness: Alpha-Line keyboard. Monitor housing: Sheet steel, silver grey (RAL 9007), spray finished, smooth Pedestal: MDF, silver grey (RAL 9007), spray finished, with stainless steel trim Base plate: MDF, spray finished silver-grey Keyboard support: Aluminium, anodised Individual material variants available on request. 53

54 Interactive Terminal Systems ITS Arc-Line The ideal terminal for hard facts and canny businessmen. For robust communications with a stable base and perfect protection, made entirely from spray finished sheet steel or stainless steel. Corners and edges with plenty of character. Ergonomics and design at their very best. Operation is child s play. Fully fitted and ready to use in line with the customer s requirements. With top-quality 17 CRT monitor. Optionally with touchscreen or keyboard. And optionally for individual requirements: Coin checker and card reader. What more could you need? ITS Arc-Line Housing design Basic Front Door Metallic Classic CRT monitor Contact sensor (touchscreen) including controller Keyboard support for the insertion of ITS keyboards Basic electrical equipment with cabling and power pack for display and sound system ( V, 50/60 Hz) Door hinged, rear hinged, front hinged, rear hinged, rear Material Sheet steel Sheet steel Sheet steel Stainless steel (V2A) Surface finish Spray finished in RAL 7016 (finely textured) Spray finished in RAL 7016 (finely textured) Hand-polished, powder-coated in clear paint Hand-brushed Dimensions of terminal enclosure approximately 640 x 1155 x x 1155 x x 1155 x x 1155 x 560 (W x H x D mm) Model No. ITS Accessories Active sound system including 2 speakers, fitted ITS PC system Silent (for details, see Accessories, page 58) ITS PC system Pro (for details, see Accessories, page 58) ITS PC system Basic PC operating system 2) MS Windows XP Home, German 1) PC operating system 2) MS Windows XP Home, English 1) Membrane keyboard 3), German 1) for Arc-Line Touchpad for membrane keyboard Trackball for membrane keyboard Stainless steel keyboard 3), German 1) for Arc-Line Trackball for stainless steel keyboard Hardware kit printer Mains connection cable, Germany (Length approx. 2.5 m) Mains connection cable, UK (Length approx. 2.5 m) Mains connection cable USA/Canada (Length approx. 2.5 m) ) Internet-specific layout and other language variants available on request. 2) Operating system OEM version may only be ordered in conjunction with a PC system; other operating systems available on request. 3) Keyboards with Internet-specific layout. Other accessories: DSL/ISDN modems and card readers etc. available on request. 54 Rittal IT News 2003

55 17 monitor protected behind glass. Perfectly integrated: Membrane keyboard, touchpad (or trackball). Which design do you prefer? Brushed, polished or powder coated stainless steel? Basic and Front Door versions: Sheet steel, spray finished (RAL 7016, finely textured) Metallic version: Sheet steel, hand-polished, powder coated in clear paint Classic version: Stainless steel (V2A), hand-polished 55

56 Interactive Terminal Systems ITS Out-Line Pro This ITS outdoor terminal system was designed for multimedia in an outdoor setting. Based on Rittal s expertise in the outdoor sector, this twin-walled aluminium terminal offers a high level of security in terms of protection from a wide variety of climatic and physical conditions, including protection against vandalism. In spite of these tough requirements, the designers have created a stylish terminal system which blends harmoniously into its surroundings. The curved form of the roof structure, which as well as being visually appealing also provides protection from the elements for both the terminal and its users, contributes to the open, inviting design. Inside, the enclosure may be configured with other components from the Rittal range of accessories, such as component shelves etc. Special displays suitable for outdoor use with high levels of light intensity are used in complete systems. At the customer s request, other installed equipment such as smartcard and magnetic card readers, special thermo-transfer printers and motion sensors for specialist applications may also be integrated. ITS Out-Line Pro TFT display (suitable for outdoor use with an increased light intensity) Contact sensor (touchscreen) including controller Keyboard support for the insertion of ITS keyboards Basic electrical equipment with cabling and power pack for display and sound system ( V, 50/60 Hz) Base/plinth with stabilisers, may be screw-fastened to the ground Dimensions of terminal enclosure approximately (W x H x D mm) 650 x 2000 x x 2000 x x 2000 x x 2000 x 550 Dimensions of terminal including roof approximately (W x H x D mm) 1000 x 2400 x x 2400 x x 2400 x x 2400 x 1000 Model No. ITS Accessories Active sound system including 2 speakers, fitted ITS PC system Silent (for details, see Accessories, page 58) ITS PC system Pro (1 U, for details, see Accessories, page 58) ITS PC system Basic PC operating system 2) MS Windows XP Home, German 1) PC operating system 2) MS Windows XP Home, English 1) Stainless steel keyboard with trackball, IP 65, German 1) Stainless steel keyboard with trackball, IP 65, English 1) Membrane keyboard with touchpad, German 1) Membrane keyboard with touchpad, English 1) WLAN upgrade kit IEEE , type 2 (PCI card with external outdoor aerial for the PC system Pro and Basic ) Climate control kit for outdoor terminals, type 1 (mains voltage: 115 V) Climate control kit for outdoor terminals, type 2 (mains voltage: 230 V) ) Other language variants available on request. 2) Operating system OEM version may only be ordered in conjunction with a PC system; other operating systems available on request. Further accessories such as card reader, motion sensor etc. available on request. 56 Rittal IT News 2003

57 Aluminium, spray finished Tubes: Steel, spray finished Protection category: IP 55 Colour: RAL 9007 Various spray finishes available on request. The base/plinth is screwed to the ground for stability. As well as the ITS PCs, mm (19 ) technology such as component shelves may also be integrated. Protection against vandalism also extends to the details: Robust stainless steel keyboard with trackball. A high protection category is achieved, thanks to a sealing frame and lock system. 57

58 Accessories for ITS ITS Mini-PC system Rittal now offers innovative PC technology to match the terminal systems which is specifically tailored to the requirements of the kiosk sector. There is a choice of two PC systems which are ideally suited for use in all terminal systems in terms of noise emission, system performance and compact design. Compulsory for use in the Opti-Wall and Alpha-Line, but optional in the Arc-Line, Opti-Desk and Opti-Line II (to dispense with the PC case which would otherwise be required, where additional installation space is required for hardware components such as printers, coin checkers or card readers). With the PC system Silent, the designers focussed their attention on a noise- and heat lossreducing design. In this way, we have managed to dispense with the use of active fans for the power pack and for cooling the PCU. In the Pro variant, the power pack with low-noise fan is integrated into the PC housing. The dimensions, which support the installation of common mainboards based on the Micro- & Flex-ATX standard, make this enclosure suitable for customerspecific solutions, in addition to the standard configuration shown here. ITS Mini-PC configuration 1) Model variant Silent Pro Fanless PC (Mini-ITX, VIA Eden CPU) Intel Celeron CPU with active fan (at least 1700 MHz) Main memory 128 MB 256 MB Hard disk (minimum capacity, approx.) 40 GB 60 GB CD-ROM DVD-ROM Interfaces PS/2 (keyboard and mouse) VGA (onboard) Sound (onboard, 6-way surround sound 5.1, AC97 codec) connections in/out 2/1 Sound (onboard AC97 codec) connections in/out 2/1 Ethernet 10 und 100 Mbit/s (RJ 45) Serial (RS232 9 pin) 1 x 1 x Parallel (ECP/EPP) 1 x 1 x USB 2 x USB x USB 2.0 Firewire (IEEE 1394) 2 x SP-DIF out (RCA, if TV-out is not used) TV-out (PAL & NTSC) (RCA, if SP-DIF is not used) PCI extension slot (via optional riser card) 1 x Dimensions approximately W x H x D mm 300 x 55 x x 1 U x 360 Model No. ITS Model No. Empty enclosure, with power pack ( V, 50/60 Hz) Accessories 1) Power pack (12 V sec.) for PC system Silent ( V, 50/60 Hz) Mains connection cable, Germany (Length 2.5 m) Mains connection cable, UK (Length 2.5 m) Mains connection cable USA/Canada (Length 2.5 m) PC operating system 2) MS Windows XP Home, German 3) PC operating system 2) MS Windows XP Home, English 3) WLAN upgrade kit IEEE type 1 (USB) WLAN upgrade kit IEEE type 2 (PCI card with external aerial) ) We reserve the right to make configuration changes in line with technical progress. 2) Operating system OEM version may only be ordered in conjunction with a PC system! 3) Other language variants available on request. Long-stroke keyboard Super-slimline, compact long-stroke keyboard (83/84 keys) with top-quality 16 mm trackball. Available in two different colours and country layouts. Dimensions W x H x D: 370 x x 20 mm. Black Model No. ITS Beige Model No. ITS Long-stroke keyboard, German Long-stroke keyboard, US English For self-installation in the keyboard supports of Alpha-Line and Opti-Line II, an adaptor plate is additionally required. Adaptor plate in brushed stainless steel Adaptor plate, black sheet steel (RAL 9005) Model No. ITS Rittal IT News 2003

59 Accessories for ITS Stainless steel keyboard Stylish stainless steel keyboard with trackball (38 mm ball diameter). The stainless-steel full-stroke keys with a stroke of 3.5 mm are laser-engraved and protected against being twisted out or snapped off. The keyboard conforms to CE requirements. Stainless steel keyboard with trackball Stainless steel keyboard with trackball Language Model No. ITS German English Protection category: Keyboard: IP 65 Membrane keyboard for Arc-Line For installation in the keyboard supports for Arc-Line. Surf the world wide web with ease: Separate keys for key Internet-specific functions are provided on the membrane keyboard. The touchpad or trackball allows you to navigate in all directions on the screen. Dimensions (W x H x D) mm: Keyboard: 303 x 113 x 17 Touchpad: 98 x 113 x 17 Trackball: 98 x 113 x 31 Colour: RAL 7035 Protection category: Keyboard and touchpad: Front IP 65 Trackball: IP 54, idle Model No. ITS Keyboard Touchpad Trackball Benefits: SMD short-stroke key, actuator travel 0.25 mm All input devices are wipe-clean and resistant to standard cleaning agents and solvents to DIN No additional drivers are required. With Internet-specific function keys and encrypted special keys for crash-proof operation by the user. 3 m connection cable with PS/2 connector. Stainless steel keyboard for Arc-Line For installation in the keyboard supports for Arc-Line. Offers all the benefits of a membrane keyboard (see above) but additionally with: Laser-engraved V2A (stainless steel) key caps and V2A front panel. Suitable for damp outdoor conditions, thanks to its exceptionally robust design. Dimensions (W x H x D) mm: Keyboard: 303 x 113 x 17 Touchpad: 98 x 113 x 17 Trackball: 98 x 113 x 31 Stainless steel Model No. ITS Keyboard Trackball Protection category: Keyboard and touchpad: Front IP 65 Trackball: IP 54, idle Note: Other keyboards e.g. silicone keyboards, long-stroke keyboards etc. are also available on request. Optional fittings Rittal offers an extremely broad spectrum of solutions. Naturally, we can also accommodate other tasks outside of this modular solution concept. Interactive terminal systems may be equipped e.g. with the following additional components to meet individual application requirements: Panel PC system Smartcard/bank card reader unit Coin checker PC hinged base system for independent installation of a PC in VIP-Line, Out-Line Flex, Out-Line Modul Receipt or laser printer Special spray finish for outdoor siting Web-cam Individual printing and inscription. Rittal IT News

60 Power System Rack Water cooling, cable management Cable management Power System Module Water cooling Need a holistic solution? We can supply it. And at a very high level (up to Level 4). The Power System Rack offers an ingeniously simple answer: Power distribution, cable management and water distribution are incorporated into the frame section. Water cooling Higher performance for CPUs, power packs and disk drives by cooling directly at the site where heat is generated. The profile of the flexrack (i) allows inlet and return lines to be integrated for targeted, safe water cooling. They are linked to an external recooling unit. The drip-free quickrelease coupling ensures an extremely high level of operational reliability. The tried-andtrusted Rittal CMC module monitors the target/actual temperature. 1 CPU CPU CPU CPU CPU CPU CPU CPU CMC CPU Case example: ➀ CPU cooling elements ➁ Water distributor ➂ CMC-TC to monitor and control the inlet temperature ➃ Recooling system Integral cable management The flexrack (i) profile is multifunctional: Cable management may be integrated into the integral hollow space via simple clip-on mounting, without loss of U. The cable shunting components may be used in 600 and 800 mm wide enclosures. A cable duct is also created in conjunction with the mm (19 ) section. 60 Rittal IT News 2003

61 Power System Rack Power System Module Power System Module The ever-growing power requirements of modern IT structures demand refined solutions for power distribution inside the racks. This leads to an associated requirement for additional sockets. The new intelligent power distribution system from Rittal significantly reduces cabling and assembly work. The modular system facilitates basic configuration of the racks, thanks to a vertical support rail with 3-phase infeed. The various insert modules to supply the active components may be snap-fitted into the support rail. This can even be done whilst the system is operational, because the support section is shock-hazardprotected. The various modules, earthing pins, IEC320 etc. may be inserted into the support rail in any combination. This is easily achieved, even by non-electricians, thanks to the shock-hazard-protected plug & play system. Technical specifications/benefits: 3-phase construction with a maximum current of 3 x 16 A. A redundant three-phase infeed with 3 x 16 A may also be added. The redundant circuit is completely separate from the 3 phases of the support rail. The connection direction of the modules on the support rail allows the operator to choose whether power supply is via 3 x 16 A or via the 3 x 16 A redundant circuit. Modules may be retrofitted whilst the system is operational. All plug-in modules are equipped with an integral miniature circuit-breaker, so that only the affected module is deactivated in the event of a shortcircuit. The other modules remain operational. Overvoltage protection modules available. Easily installed in all enclosure systems. Max. 96 A per Power System Module Support rail is easily integrated into the vertical frame section of the Power System Rack. The vertical support rail allows the slots to be used flexibly across the entire enclosure height, and configured in a redundant manner via separate power infeed to the individual modules. Supply includes: Busbar with infeed module, assembly parts and operating instructions. Also required: Plug-in modules, see table below. Section, busbar, plug-in module Busbar with infeed module Direct integration into the flexrack (i) Busbar with supply module For enclosure height mm Assembly kit for retrofitting in other enclosure systems Model No. DK Without fuse Without fuse With fuse * With fuse * * Extended delivery times Assembly kit For enclosure height mm Model No. DK Infeed module Plug-in modules Other modules available on request. Nonheating Plug-in module D/A F/B USA UK CH appliances Number of sockets Without fuse * * * * With fuse * * * * Extended delivery times Two plug-in modules, overvoltage protection Overvoltage protection Overvoltage protection Model No. DK Rittal IT News

62 Accessories for flexrack (i) Side panel, lockable for FR (i) The side panel is simply plugged in and secured via two security locks. The integral beading gives the side panels a special touch. Additional security is achieved via the option of latching the side panel from the inside. The side panels may be screwfastened to the frame section from the inside using locking brackets Sheet steel, spray finished Colour: RAL 7035 Protection category: IP 20 Supply includes: 2 side panels including security lock 3524 E. For enclosures Height mm Depth mm Model No. FR (i) Baying kit for FR (i) For baying the second generation of the FR enclosure to existing first-generation enclosures, or within the same enclosure system. Sheet steel Surface finish: Zinc plated, passivated Supply includes: 1 set of baying connectors including assembly parts. Baying of/to Packs of Model No. FR (i) FR (i) /FR 1 set FR (i) /FR (i) 1 set Note: For baying the new enclosure system together, all baying connectors in the TS 8 series may also be used, which link the horizontal frame sections of the enclosure to one another. See IT Catalogue 2002/accessories for TS Rittal IT News 2003

63 Accessories for flexrack (i) System adaptor FR (i) Use of the system adaptor within the FR (i) frame allows the operator to easily create two attachment levels within this enclosure system. This supports the integration of all rail systems which are attached to the outer enclosure level and therefore offers a diverse choice of installation options. The inner attachment level may be emulated by simply twisting the system adaptor, and therefore creates the requirements for perfect cable management and completely flexible interior installation. Rail systems attached between the front and rear frame section must be 200 mm shorter than the standard dimensions. Sheet steel Surface finish: Zinc plated, passivated Supply includes: 8 system adaptors, including assembly parts. Packs of Model No. FR (i) Installation position, outer level Installation position, inner level Mounting angles, mm (19 ) for FR (i) For front installation as far forward as possible, e.g. in the form of an electronic enclosure, these mounting angles may be attached directly to the enclosure frame section at the front. Upon request the mounting angle may be rotated through 180, so as to create additional free space for cable routing in the front section. Side openings allow the hollow section of the enclosure frame to continue being used for cable routing. Sheet steel Surface finish: Zinc plated, passivated Supply includes: 2 mounting angles, including assembly parts. Enclosure height mm Useful U for full installation Model No. FR (i) Rittal IT News

64 Accessories for flexrack (i) / TS 8 Roof plate for cable entry, two-piece for FR (i) /TS 8 In exchange for the standard roof. Convenient cable entry from above is achieved via the brush strips in the rear section. The two-piece design of the roof plate facilitates simple retro-fitting of cables at any time, by removing the front part of the plate. The pre-existing cables are held in position via a guide at the side. The roof plate can be raised with spacers, for passive ventilation. Sheet steel, spray finished Colour: RAL 7035 For enclosures Width mm Depth mm Model No. DK Accessories: Spacers, see IT Catalogue 2002, page 363. Roof plate, vented for FR (i) /TS 8 In two versions. In exchange for the standard roof. 72 mm high roof plate, all-round vent slots, optionally with brush strip for cable entry. The two-piece design with cable entry allows easy retro-fitting, by simply removing the front part of the plate. The pre-existing cables are held in position via a guide at the side. For enclosures Width mm Depth mm Model No. DK One-piece without cable entry Two-piece with cable entry Rittal IT News 2003

65 Accessories for flexrack (i) / TS 8 Fan roof, modular, two-piece for FR (i) /TS 8 The modular roof plate consists of individual components and can be compiled to suit the ventilation requirements of FR (i) /TS 8 enclosures. The modules: Roof plate with cutout ➀ Fan insert and cable entry at the rear via brush strip. In exchange for the existing roof plate. The two-piece design allows convenient retrofitting of cables at any time. Cover plate To conceal the cutout, optionally solid ➂ or vented ➃. The top-mounted cover plate may be raised for extra air throughput using the supplied spacers. Fan insert ➁ For active ventilation: A fully pre-wired fan tray including 2.5 m connection cable, with two fan motors and additional cutouts. The air throughput may be increased with a fan expansion kit. Sheet steel, spray finished Colour: RAL 7035 Technical specifications for one fan: Bemessungsbetriebsspannung: 230 V Nennleistung: 19/18 W at 50/60 Hz Luftleistung (unimpeded airflow): 140/165 m 3 /h at 50/60 Hz Temperaturbereich: 10 C to +55 C Accessories: Fan expansion kit , see IT Catalogue 2002, page 365. Thermostat , see IT Catalogue 2002, page 329. Speed control , see IT Catalogue 2002, page For enclosures Model No. DK Cover plate Fan insert Roof with Fans Width Depth Solid Vented Fan insert cutout prewired in mm mm ➀ ➂ ➃ ➁ the factory Maximum no. of fans Designer trim panel for base/plinth for FR (i) /TS 8 The base/plinth trim is the perfect complement to the special design of the TS 8 designer glazed doors and designer sheet steel doors in the base/plinth region, and helps to create a striking overall impression. The trim panel is simply exchanged for the existing front trim panel of the base/plinth. Sheet steel, spray finished Design elements aluminium, spray finished Surface finish: RAL 7035 Front trim panel RAL 7024 Supply includes: 1 front trim panel, including assembly parts. Enclosure width mm Design Packs of Model No. DK 800 Solid Vented Rittal IT News

66 Accessories for flexrack (i) / TS 8 Stabiliser bracket for base/plinth mounting on the FR (i) /TS 8 Using this bracket substantially increases the stability of individually sited FR (i) /TS 8 enclosures. If an installed component is extended, it ensures stability for up to 80 kg with full extension. The stabiliser bracket may be retrospectively screw-fastened to the outside of the FR (i) /TS 8 base/plinth corner pieces. Packs of Model No. DK Sheet steel, spray finished Surface finish: RAL 7035, warning markings RAL 2002 Supply includes: 2 stabiliser brackets, including assembly parts mm (19 ) mounting frame for FR (i) /TS 8 The firmly linked mm (19 ) mounting frame may be mounted with complete depth variability inside FR (i) /TS 8 enclosures and is used to structure the front and rear pair of mm (19 ) mounting angles. Support of the mounting frame on the enclosure frame, coupled with its robust design, ensures a high load capacity. The mounting frame has the same system punchings as the TS 8 enclosure frame at the sides and rear, and therefore supports the mounting of various TS 8 installation accessories such as cable clamp rails, cable shunting rings etc. Load capacity: Up to 1000 kg static load, with even load distribution on two mm (19 ) mounting frames, with full installation. Sheet steel Surface finish: Zinc plated, passivated Supply includes: mm (19 ) mounting frame, including assembly parts. For enclosures Model No. U Width mm Height mm FR (i) Note: A combination of mm (19 ) mounting frame plus fan mounting plate is not possible. For active ventilation, we recommend combined use with the modular fan roof for FR (i) /TS 8. Accessories: Captive nuts and fastening screws, cable clamp rails for TS 8, depth-variable slide rails, component shelves etc., see IT Catalogue Rittal IT News 2003

67 Accessories for flexrack (i) / TS 8 Extension kit for horizontal cable management for FR (i) /TS 8 The extension kit allows the enclosure frame to be extended in the depth by approximately 100 mm. The space thereby acquired may be used for horizontal cable management between bayed enclosures. Upon request, trim panels may be inserted on the outer sides of the bayed enclosure suites to protect the enclosures against unauthorised access. Combination of the extension kit with divided doors is not possible. Sheet steel, spray finished Colour: RAL 7035 Supply includes: Extension kit consisting of 8 spacer supports, including assembly parts. Trim panels: Packs of 2 Expansion kit: Packs of Model No. FR (i) 1 set Trim panels: Enclosure height mm Model No. FR (i) Stabiliser for server racks for FR (i) /TS 8 The pull-out stabiliser is quickly and easily retrofitted to the base frame of an FR (i) or TS 8 server rack and only extended when necessary. It may be used in combination with levelling feet and/or castors. The stabiliser cannot be used together with gland plates or base/plinths. Load capacity: Up to a maximum of 150 kg static load. Sheet steel, spray finished Surface finish: RAL 9006 Supply includes: 1 stabiliser including assembly parts. Enclosure depth mm Model No. DK Rittal IT News

68 Monitor/keyboard unit with 15 TFT screen TFT screen 17 TFT screen Technical specifications of enclosure mm (19 ) unit, 1 U approx. 490 mm deep approx. 600 mm deep Including mounting kits for installation in mm deep enclosures mm deep enclosures Illuminated on/off switch on the front Automatic backlight deactivation when folded down Lockable at the front 2 x speakers 8 ohms, 0.25 W Technical specifications of monitor TFT screen with anti-reflection coated security glass On-screen display, multi-lingual Maximum resolution 1024 x 768 pixels 1280 x 1024 pixels Colours 16.7 million 16.7 million Brightness 250 cd/m cd/m 2 Contrast ratio, approx. 350 : : 1 Mains voltage V AC, Hz, 45 W V AC, Hz, 45 W Connections at rear Mains voltage (IEC 320 connection) Video inputs VGA, Sub-D 15-pole VGA, Sub-D 15-pole and DVI Keyboard PS/2 PS/2 Mouse PS/2 PS/2 Audio Scope of supply Monitor/keyboard unit, fully populated, including assembly parts and connection cable (approx. 1.6 m) for: Power supply VGA DVI Sound Keyboard connection Mouse connection We reserve the right to make changes in line with technical progress. 1 U monitor/keyboard drawer Design TFT Keyboard layout Colour Packs of Model No. Touchpad mouse + numeric keypad 17 German RAL Touchpad mouse + numeric keypad 17 English RAL Touchpad mouse + numeric keypad 17 French RAL * Touchpad mouse + numeric keypad 15 German RAL Touchpad mouse + numeric keypad 15 German RAL * Touchpad mouse + numeric keypad 15 English RAL * Touchpad mouse + numeric keypad 15 English RAL * Touchpad mouse + numeric keypad 15 French RAL * Touchpad mouse + numeric keypad 15 French RAL * Trackball 15 German RAL * Trackball 15 International** RAL * * Extended delivery times ** International, please specify your keyboard layout, see table below. International**, please specify your keyboard layout US English with symbol Belgian French UK English Swiss Swedish/Finnish Italian Norwegian Spanish Danish Portuguese Note: This compact 1 U console was developed for secure, space-saving, on-site server administration. To be able to access other servers, this monitor/keyboard unit is easily combined with the Rittal SSC (see IT Catalogue 2002, page 310). 68 Rittal IT News 2003

69 Accessories Monitor / keyboard unit, 1 U Sheet steel, spray finished Colour: RAL 7035/RAL 9005 We reserve the right to make design changes. The keyboard layout is available in various languages. Instead of the numeric keypad and touchpad, variants with trackball are also available. Hinged cable routing protects the cables against damage, even if the drawer is extended and retracted frequently. 17 TFT screen with a maximum resolution of 1280 x 1024 pixels, 2 speakers and VGA/DVI video inputs. Rittal IT News

70 R Accessories General SUN USB converter This converter converts the signals from an SUN server with USB output into VGA and PS/2 standard, thereby enabling the connection of latest-generation SUN servers to the Rittal SSC or to the 1 U monitor/keyboard drawer. The commands from the SUN special keys remain usable, and are simulated on the PS/2 keyboard by means of key combinations. Power supply is via the SUN USB interface. Supplied with USB cable. W x H x D mm Model No. DK 105 x 26 x Extended delivery times. Prices on request. Also required: For use with SSC a CPU cable (PS/2, HD15) DK X0 is required. SSC remote MUX for administration of the server pool from the workstation By using an SSC remote MUX, a second console can be positioned at a distance of 10 m up to a maximum of 200 m from the workplace using a Cat 5 cable. The Cat 5 converter is pre-integrated into the SSCmulti. It additionally supports the connection of up to two local workstation computers. To this end, the standard CPU cables XX (PS/2 or SUN) are used. The changeover is implemented using the front keys or a definable keyboard hotkey. Integral video tuning facilitates picture adjustment with various Cat 5 cable qualities. Technical specifications: Rated voltage: V Computer types: PS/2 and SUN Video: Standard VGA interface Resolution: 1600 x 1200 at 85 Hz Video bandwidth: up to 250 MHz H/V sync: 130 khz/120 Hz (depending on length) Keyboard/mouse: PS/2, serial mouse, Intelli-Mouse, Explorer Mouse, SUN, plus others via adaptation W x H x D mm Model No. DK 270 x 44 x Extended delivery times. Prices on request ➀ SSCmulti ➁ Power supply cable 230 V ➂ Local console in the server room ➃ CPU cable ➄ SSC remote MUX ➅ The workstation hardware is used as a remote console Cat Rittal IT News 2003

71 Accessories General Keyboard drawer 1 U, for mm (19 ) attachment level 1 U keyboard drawer for mounting on the front mm (19 ) angles, fully extendible, lockable and with practical cable routing and strain relief. The drawer is suitable for the installation of mm (19 ) keyboards. Internal dimensions W x H x D: approx. 420 x 40 x 230 mm. Sheet steel Surface finish: Spray finished, RAL 7035 Height Model No. DK 1 U Supply includes: 1 drawer including assembly parts, without keyboard. Accessories: 19 long-stroke keyboard with numeric keypad and touchpad, connection cable (approx m) and PS/2 connector, colour RAL W x H x D mm Keyboard layout Model No. DK 415 x 37 x 193 German x 37 x 193 US English Drawer, mm (19 ) 2 U, 3 U for one mm (19 ) attachment level For front attachment to mounting angles, mm (19 ). With cover and telescopic slides to accommodate assignment lists, operating manuals and small parts. The small version of the 2 U variant is also suitable for mounting inside a swing frame. Sheet steel Colour: RAL 7035/RAL 7032* Supply includes: Fully mounted, including assembly parts. Height Clearance openings Model No. Width Depth DK mm mm 2 U U * 3 U * *To order in RAL 7032, please add extension.000 to the Model No. Installation depth: 427 mm Component shelf 1 / 2 U, depth-variable for mm (19 ) attachment level This space-saving component shelf is screw-fastened to the front and rear mm (19 ) attachment level. It is infinitely depth-adjustable and may be fitted independently from the enclosure. Combination with telescopic slides is not possible. Distance between angles Model No. DK mm Load capacity: 50 kg surface load, static Sheet steel Surface finish: Spray finished, RAL 7035 Supply includes: 1 component shelf, including assembly parts. Rittal IT News

72 Accessories General Depth-variable installation kit for mm (19 ) component shelves Infinitely adjustable to the spacing between the two pairs of mm (19 ) mounting angles. Suitable for all mm (19 ) component shelves in 409 mm width. May also be combined with telescopic slides. Only for L-shaped mounting angles! Sheet steel Surface finish: Zinc plated, passivated Supply includes: 2 mounting rails including assembly parts. Length Load capacity Accessories: mm (19 ) component shelves, see IT Catalogue 2002, page 107. Telescopic slides, see IT Catalogue 2002, page 460. Model No. DK mm 50 kg mm 50 kg mm 100 kg Packs of 1 kit Depth-variable slide rail, 1 U This slide rail facilitates flexible integration of mm (19 ) components without loss of installation height in all enclosures with L-shaped mounting angles in enclosure series TS, QR and FR (i) and their server variants. Installation of the slide rail is independent from the chosen distance between levels, since the installation length may be flexibly adapted. Sheet steel Surface finish: Zinc plated, passivated Length Load capacity Support surface W x D Supply includes: 2 slide rails including assembly parts. Model No. DK mm 50 kg 50 x 330 mm mm 80 kg 50 x 525 mm mm 150 kg 50 x 525 mm Fibre-optic cable management panel, 2 U, mm (19 ) This panel supports routing of the fibreoptics whilst observing the minimum bend radii within horizontal and vertical cable management. Sheet steel Surface finish: Spray finished, RAL 7035 Supply includes: 1 cable management panel Packs of Model No. DK Rittal IT News 2003

73 Accessories General mm (19 ) adaptor, 3 U Depth offset 100 mm This adaptor is used to reset mm (19 ) mounting of equipment inside enclosures with 19 installation in the foremost position, for server or electronic enclosures. In this way, sufficient space can be gained in front of the mounting equipment to integrate patch panels or switches, whilst at the same time exploiting the maximum enclosure depth. Sheet steel Surface finish: Zinc plated, passivated Packs of Model No. DK 1 kit Supply includes: 2 adaptors, including assembly parts. Adaptor, metric/ mm (19 ), 21 /19 With this adaptor, mm (19 ) assemblies may be fastened to metric (535 mm) mounting angles, or combined systems may be configured. Extruded aluminium section SU U Packs of Model No. DK kit kit kit Supply includes: 2 adaptors, including assembly parts. EL gland plate for metric cable glands Multi-folded and firmly linked gland plate with foamed-in seal and pre-punched, knock-out holes for metric cable glands M12/M20/M25/M32/M mm sheet steel Surface finish: Electrophoretic dipcoat primed. Spray finished in textured RAL 7032/7035. Protection category: IP 55 Supply includes: Gland plate Design Packs of Model No. DK RAL RAL (7 x) (4 x) 32.5 (2 x) (2 x) 25.5 (5 x) Rittal IT News

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,

More information

Make IT easy: The new TS IT rack

Make IT easy: The new TS IT rack Make IT easy: The new TS IT rack The new TS IT rack. A new global standard for network and server equipment. At CeBIT 202, Rittal unveiled a newly developed rack system which is set to redefine the global

More information

TopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389

TopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389 opconsole system P System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389 Enclosure: Sheet steel 1.5 mm Door and console cover: Sheet steel, 2.0 mm, all-round foamed-in

More information

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact... IT monitoring Monitoring system system representation...446 system overview...448 Processing Unit/Compact...450 sensors/accessories control units/ sensors...45 Interface for CMC II sensors...45 Access

More information

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment) 25 Accessories for control enclosures BERNSTEIN attachment Single coupling head (suspended console version) Double coupling head (console version with suspension system attachment) 322.5 231 232 140 The

More information

Console systems 1.4. Features. TopConsole system TP. One-piece consoles AP. Universal consoles AP. Console systems

Console systems 1.4. Features. TopConsole system TP. One-piece consoles AP. Universal consoles AP. Console systems Console systems Features he performance capability of a machine or plant is decided at the console and operating unit. Rittal have set new standards in ergonomics, visual appearance and functionality for

More information

Flex-Block base/plinth system. Packs of

Flex-Block base/plinth system. Packs of Base Flex-Block base/plinth system Baying clip for baying the Flex-Block corner pieces Simply insert the clip from behind into the recesses provided (no need for tools). Fibreglass-reinforced polyamide

More information

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

19 TiRAX cabinet system. from page 3. 19 NETcell cabinet system from page 31. Open 19 racks from page 43 9" TiRAX cabinet system from page 9" NETcell cabinet system from page Open 9" racks from page Wall-mounting/stand-alone distribution systems from page 5 Wall-mounting enclosure systems from page 6 Air

More information

The new TS IT rack Rittal IT security Rittal IT power supply Rittal IT monitoring Rittal IT climate control Rittal references

The new TS IT rack Rittal IT security Rittal IT power supply Rittal IT monitoring Rittal IT climate control Rittal references Innovations 202 The new TS IT rack... From page 4 TS IT... Page 6 3 Rittal IT power supply... From page 36 UPS Power Modular Concept... Page 38 PDU Power Distribution Unit... Page 39 43 PSM Power System

More information

Ripac VME/VME64x Systems. Applications. Design Features

Ripac VME/VME64x Systems. Applications. Design Features Overview Of Systems For VMEbus Ripac VME/VME64x Slim-Box Ripac VME/VME64x Systems Ripac VME/VME64x Systems 1, 2, 3, 4U/2, 4, 6, 8 slot in AC input Order No. see pages 110-112 For backplanes see page 60

More information

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS - Made in Turkey With Pride! HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS, the only Turkish manufacturer of state-of-the-art LAN cabling systems

More information

Technical System Catalogue CMC III Monitoring System

Technical System Catalogue CMC III Monitoring System Technical System Catalogue CMC III Monitoring System CMC III monitoring system CMC III Processing Unit 3 6 1 5 7 4 8 9 10 11 Computer Multi Control (CMC) is an alarm system for network and server enclosures,

More information

D-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing

D-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing D-Net CABINETS D-Net cabinets are a versatile racking system suitable for housing networking and various structured cabling components. D-Net Cabinets are manufactured in Taiwan in compliance with ISO9001:2000

More information

DK-PS Rack. New generation DK-PS Rack for room climate control

DK-PS Rack. New generation DK-PS Rack for room climate control DK-PS Rack DK-PS Rack New generation DK-PS Rack for room climate control Rack as the support for IT equipment is the main component of the data center; Reliable,eficiency and flexible is the main requirement

More information

INDUSTRIAL WORKSTATIONS. The new dimension at the interface between man and machine for enhanced workspace safety ergonomics

INDUSTRIAL WORKSTATIONS. The new dimension at the interface between man and machine for enhanced workspace safety ergonomics INDUSTRIAL WORKSTATIONS The new dimension at the interface between man and machine for enhanced workspace safety ergonomics Diversity is the strength of. More workspace than with a PC enclosure. More compact

More information

Vertiv Knürr MIR2 One system with Infinite Possibilities

Vertiv Knürr MIR2 One system with Infinite Possibilities VERTIV KNÜRR MIR2 4 Vertiv Knürr MIR2 One system with Infinite Possibilities Vertiv Knürr MIR, the classic amongst innovative racks, is demonstrated by the long-standing and continuous satisfaction of

More information

Pixus Technologies Catalog

Pixus Technologies Catalog The Power of Embedded Ingenuity Pixus Technologies Catalog Kaparel, Ripac, & Vario Brand Products www.pixustechnologies.com sales@pixustechnologies.com US: 96.524.8242 CAN: 59.885.5775 Product Diversity

More information

Pixus Technologies Catalog

Pixus Technologies Catalog The Power of Embedded Ingenuity Pixus Technologies Catalog Kaparel, Ripac, & Vario Brand Products www.pixustechnologies.com sales@pixustechnologies.com S: 96.524.8242 CAN: 59.885.5775 Product Diversity

More information

Probably the fastest enclosure in the world

Probably the fastest enclosure in the world 95 9 enclosure system Probably the fastest enclosure in the world Sample configuration tools required no no tools required Vitaro can be assembled within less than 60 seconds. 00:00 00:0 00:08 00: 00:5

More information

IT power distribution Power distribution units (PDU) Basic. Versions available:

IT power distribution Power distribution units (PDU) Basic. Versions available: IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,

More information

InForm Superstructures

InForm Superstructures Advantages InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices

More information

Security 5.6. Monitoring system CMC-TC. Security individual and flexible. Security. communication between the Master and Processing Unit II.

Security 5.6. Monitoring system CMC-TC. Security individual and flexible. Security. communication between the Master and Processing Unit II. Monitoring system CMC-TC individual and flexible The CMC-TC offers a new dimension in flexibility, efficiency, technology and cost-effectiveness. The modular master/slave system uses network technology

More information

Blue e+ chillers with the principle

Blue e+ chillers with the principle Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide

More information

Floor Standing Rack Cabinet

Floor Standing Rack Cabinet Floor Standing Rack Cabinet FEATURES: rear door with bolt lock front door panel with vented holes Reliable structure, static loading capacity: 600-00KG (Optional castors and plinth) Adjustable feet and

More information

PERFECT HANDLING. PCB Front Panels & Injector/Extractor Handles... Package Your Electronics With Ripac.

PERFECT HANDLING. PCB Front Panels & Injector/Extractor Handles... Package Your Electronics With Ripac. Front Panels & Injector/Extractor Handles... PERFECT HANDLING. Package Your Electronics With Ripac. When it comes to electronics, no one handles today s demanding applications better than Rittal Ripac

More information

Networking Cabinets and Enclosures

Networking Cabinets and Enclosures Networking Cabinets and Enclosures Excel is a world-class premium performing end-to-end infrastructure solution - designed, manufactured, supported and delivered - without compromise. Networking Cabinets

More information

Specification Sheet: HT SERIES

Specification Sheet: HT SERIES Specification Sheet: HT SERIES HT Series: High Specification 19 Enclosures Hi-tech Series of 19 enclosures, supplied in self assembly (flat pack) format for ease of transportation and storage. Manufactured

More information

VERAK IP. 19 Stand Alone Cabinet with IP65 Rating.

VERAK IP. 19 Stand Alone Cabinet with IP65 Rating. 19 Stand Alone Cabinet with IP65 Rating www.apw.eu.com Overview Material specification Frame: Steel 2.0 mm Panel mounting angles and reducing channels: Steel 2.0 mm Panel mount supports: Steel 1.5 mm Side

More information

InForm Superstructures

InForm Superstructures Advantages InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices

More information

PROLINE. Wall mounted cases FOR ROBUST INDUSTRIAL ENVIRONMENTS UP TO IP 66. Epcase OVERVIEW MAIN KATALOG

PROLINE. Wall mounted cases FOR ROBUST INDUSTRIAL ENVIRONMENTS UP TO IP 66. Epcase OVERVIEW MAIN KATALOG Wall Mounted Case PROLINE Main Catalogue Wall mounted cases OVERVIEW FOR ROBUST INDUSTRIAL ENVIRONMENTS UP TO IP 66 MAIN KATALOG Cabinets....... 1 Wall mounted cases......... 2 Accessories for cabinets

More information

vme, vme64x, vxs, vpx

vme, vme64x, vxs, vpx vme, vme4x, vxs, vpx VME, VME4x, VXS, VPXMain Catalogue Systems VME, VME4x, VXS, VPX OVERVIEW MAIN KATALOG Cabinets....... 1 Wall mounted cases.......... 2 for cabinets and wall mounted cases.. 3 Climate

More information

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day IT infrastructure Next level for data center Rittal The System Yavor Panayotov Data center Day - 2018 1 Rittal The System - Solutions Enclosures Enclosures Small enclosures Command Panel & support arm

More information

Monitoring system CMC III

Monitoring system CMC III Monitoring system CMC III ENCOSURES POWER DISTRIBUTION CIMATE CONTRO INFRASTRUCTURE SOFTWARE & SERVICES W x H x D mm Temperature range Operating humidity range Sensors/CAN bus connection units Max. overall

More information

PI Server - 19 enclosures

PI Server - 19 enclosures PI Server - 19 The PI server enclosure range has been designed to complement our original PI Data enclosure and to accommodate the requirement of a cost effective server cabinet solution. This product

More information

New products spring 2018

New products spring 2018 New products spring 2018 MODULAR SOLUTIONS CASY SERIES DESKTOP CHASSIS Front module mounting Large access holes on rear Structured black powder coating (RAL9004) Aluminum extruded frame with plastic sides

More information

CPCI System Subrack 1 U

CPCI System Subrack 1 U User s Manual Product No.: Doc-No: 63972-165_R1.0 January 14, 2008 Rev. Date updated Change R1.0 January 14, 2008 Initial Release Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in this

More information

Europacpro Industrial Applications

Europacpro Industrial Applications Europacpro Industrial Applications for industrial applicationsdmain Catalogue Subracks EuropacPRO for Industrial Applications OVERVIEW MAIN KATALOG Cabinets....... 1 Wall mounted cases......... 2 Accessories

More information

Power Distribution Unit

Power Distribution Unit 414 Simple assembly Compact design Toolless clip attachment in the TS-IT Flexible mounting at the required height in the zero-u space lso suitable for individual installation on the enclosure frame Reliable

More information

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP SIMBOX 63 /4 Introduction /5 Flush mounting distribution boards /6 Hollow-wall distribution boards /7 Surface mounting distribution boards /7 Hood-type

More information

SIVACON 8MC, 8MF Cubicle Systems

SIVACON 8MC, 8MF Cubicle Systems SIVACON 8MC, 8MF Cubicle Systems /2 Introduction /3 8MC System Cubicles 1) /4 8MF System Cubicles 1) /5 Accessories Technical Information can be found at www.siemens.com/lowvoltage/support under Product

More information

CPCI System Subrack 3 U

CPCI System Subrack 3 U User s Manual Product No.: Doc-No: 63972-224_R1.1 April 18, 2011 Rev. Date updated Change R1.0 January 14, 2008 Initial Release R1.1 April 18, 2011 Fan Tray with mini compression latch Impressum: Schroff

More information

ENVIRONMENTS FOR ELECTRONICS. by knürr. Miracel. 19 rack platform for data center, telecommunication and network technology

ENVIRONMENTS FOR ELECTRONICS. by knürr.   Miracel. 19 rack platform for data center, telecommunication and network technology ENVIRONMENTS FOR ELECTRONICS by knürr Miracel 19 rack platform for data center, telecommunication and network technology ENVIRONMENTS FOR ELECTRONICS by knürr Knürr Miracel & Knürr Miracel PLUS The perfect

More information

Knürr Elicon Ergonomic, modular, future-proof Cost-optimized installation options. Technical Furniture

Knürr Elicon Ergonomic, modular, future-proof Cost-optimized installation options. Technical Furniture Knürr Elicon Ergonomic, modular, future-proof Cost-optimized installation options Technical Furniture Knürr Elicon Applications Capabilities 2 Knürr Elicon Strong points 4 Knürr Elicon Modules Side Panel

More information

RittalXpress TS IT Enclosure Assemble-to-Order Program

RittalXpress TS IT Enclosure Assemble-to-Order Program RittalXpress TS IT Enclosure Assemble-to-Order Program DESIGN YOUR DATA CENTER BY THE NUMBERS. Count down to success: 4, 3, 2, 1... Complete four easy steps, your order can be shipped in three days and

More information

Racks & Integrated Cabinets. Knürr IT Special Catalog Networks and Data Centers

Racks & Integrated Cabinets. Knürr IT Special Catalog Networks and Data Centers Racks & Integrated Cabinets Knürr IT Special Catalog Networks and Data Centers Contents Introduction Page 0.2 Content Page 0.3 Complete solution from one source Cabinets/Racks Page 1.1 Knürr DCM 19 Heavy

More information

KM6-II Subracks. APW Electronic Solutions. 152 APW Electronic Solutions Toll Free (800) Fax: (858)

KM6-II Subracks. APW Electronic Solutions. 152 APW Electronic Solutions Toll Free (800) Fax: (858) KM6-II Subracks Fully compatible with DIN41494 part 5 and IEC60297-3. KM6-II Standard is available in kit form, offering quick and simple assembly. KM6-II Universal is a highly versatile subrack system,

More information

Hassle-free equipment installation

Hassle-free equipment installation 12U 36in Knock-Down Server Rack Cabinet with Casters StarTech ID: RK1236BKF This server rack provides 12U of storage space in a sleek secure cabinet for storing EIA-310 compliant 19 rackmount devices such

More information

W DATA SHEET: FREE-STANDING DATA ENCLOSURES DS

W DATA SHEET: FREE-STANDING DATA ENCLOSURES DS W DATA SHEET: FREE-STANDING DATA ENCLOSURES DS w TECHNICAL DATA Welded powder-coated sheet steel skeleton Heights: 15, 18, 22, 27, 32, 37, 42, 45 and 47 U Widths: 600 and 800 mm Depths: 400, 600, 800,

More information

S-SERIES 2 Superior Rack Solution for Data Center & Network Closets

S-SERIES 2 Superior Rack Solution for Data Center & Network Closets S-SERIES Superior Rack Solution for Data Center & Network Closets S-SERIES II RACKS AND CONTAINMENT Vertiv S-Series Rack The S-Series Rack is an innovative enclosure system that integrates your computing

More information

Electrical cabinets for server and LAN. 42 Lafer

Electrical cabinets for server and LAN. 42 Lafer Lafer@ck Electrical cabinets for server and LAN 42 Lafer Lafer@ck Lafer. Around you Lafer@ck Lafer 43 Lafer@ck Electrical cabinets for server and LAN They are designed for all information systems and data

More information

Thermal management. Thermal management

Thermal management. Thermal management Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately

More information

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KMF 720 Constant climate chambers with expanded temperature / humidity range Model KMF 720 Constant climate chambers with expanded temperature / humidity range The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this constant

More information

DIGITUS Server Cabinet Unique Series

DIGITUS Server Cabinet Unique Series 15 Years Product Warranty kg loading capacity Modular aluminum frame construction large range of equipment available Overview DIGITUS Server Cabinet Unique Series 600, 800 mm width mm depth Features Safety

More information

Switch cabinet housings. Distribution housings. Appropriate housings for each application. Our experience. Your safety.

Switch cabinet housings. Distribution housings. Appropriate housings for each application. Our experience. Your safety. Switch cabinet housings Distribution housings Appropriate housings for each application Our experience. Your safety. Overview of the housing ranges Mounting rail bus system In-Rail Bus...6 Switch cabinet

More information

EMEA. Product Catalog. RackLine. AT&T Rack & Enclosure LAN Cabling Products. AT&T Cabling Systems

EMEA. Product Catalog. RackLine. AT&T Rack & Enclosure LAN Cabling Products. AT&T Cabling Systems EMEA Product Catalog 2014 AT&T Rack & Enclosure LAN Cabling Products AT&T Cabling Systems provide complete enterprise solutions and state-of-the-art LAN cabling components for all needs. AT&T Cabling Systems

More information

RE Series Rack from Eaton Product Presentation

RE Series Rack from Eaton Product Presentation RE Series Rack from Eaton Product Presentation AUG 2018 Quick Overview What is Eaton s RE Series Rack Platform? RE Series is an amalgamation of the NR & RE Series with many value-add component enhancements;

More information

SSL Modular Sign & Display Systems

SSL Modular Sign & Display Systems SSL Modular Sign & Display Systems Wayfinding signs and information displays for architectural, corporate and public sector projects tel: 01934 852 888 fax: 01934 852 816 email: sales@signscape.co.uk /

More information

Cabinet. DT-NCW NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT

Cabinet. DT-NCW NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT Cabinet DT-NCW-2-6409 NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT SPCC cold rolled steel One section wall mount rack Fan, shelf for optional DT-NCW-2-6412 NETWORK CABINET 12U - 60(W)x45(D)x59(H)

More information

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security aesthetics c Elegant and robust design. c Colour easy to integrate in any environment. weatherproof & versatile enclosures multi-functional c Different solutions for: industrial control, electrical distribution,

More information

R u b b e r d i s t r i b u t o r

R u b b e r d i s t r i b u t o r Rubber distributor The modular rubber distributor series We live in a fast-moving time. It is also frequently necessary to make modifications to power distribution systems. Power distributors used in industrial

More information

Liquid Cooling Package LCP Cooling Systems

Liquid Cooling Package LCP Cooling Systems Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative

More information

Product Guide. Server Safes & Cabinets Modular Caging Security Walling Modular Enclosures

Product Guide. Server Safes & Cabinets Modular Caging Security Walling Modular Enclosures Product Guide Server Safes & Cabinets Modular Caging Security Walling Modular Enclosures Ventis Server Safe The Ventis Server Safe is a high security safe suitable for servers, sensitive data and all 19

More information

System solutions for your energy requirements

System solutions for your energy requirements System solutions for your energy requirements Power distribution from the smallest to the largest The tried-and-tested, highly fl exible power distribution system for individual requirements. From small

More information

Modular PDU Smart metering for your IT

Modular PDU Smart metering for your IT Modular PDU Smart metering for your IT Extremely flexible The modular PDU 2 Rittal modular PDU Modern IT equipment is constantly evolving, requiring permanent adjustments to the IT infrastructure. With

More information

Ideal protection for your electrics: häwa cable ducts

Ideal protection for your electrics: häwa cable ducts Ideal protection for your electrics: häwa cable ducts Well Conceived The häwa group has established itself as an innovative and highly competent supplier to machinery and facility equipment companies in

More information

UltraRack. Advanced Data Centre Enclosures SR SERIES

UltraRack. Advanced Data Centre Enclosures SR SERIES UltraRack Advanced Data Centre Enclosures SR SERIES Designed for scaleable growth The SR Series UltraRack SR Series - Universal rack enclosure solutions for advanced storage, cooling, power distribution,

More information

Hassle-free equipment installation

Hassle-free equipment installation 22U 36in Knock-Down Server Rack Cabinet with Casters StarTech ID: RK2236BKF This server rack provides 22U of storage space in a sleek secure cabinet for storing EIA-310 compliant 19 rackmount devices such

More information

XL 4000 metal free-standing enclosures and cable compartments

XL 4000 metal free-standing enclosures and cable compartments 87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax : 05 55 06 88 88 XL metal free-standing enclosures and CONTENTS PAGE 1. General characteristics...1 2. Range...2 3. Overall dimensions...2 4. Equipment...3

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

Insulated Enclosure KU 4090 to DIN for installation in distribution cabinets or surface mounting

Insulated Enclosure KU 4090 to DIN for installation in distribution cabinets or surface mounting Insulated Enclosure KU 4090 to DIN 43 880 for installation in distribution cabinets or surface mounting Width 105 mm Uo to 48 plus-minus-terminal screws with self raising terminal washers. Part insertion

More information

LSFC Power Factor Correction Systems

LSFC Power Factor Correction Systems LSFC Ready to connect, automatic in sheet steel cabinets for floor installation. Suitable for networks without harmonic distortion. Power Range: 100 to 00 kvar Modular construction in freestanding sheet

More information

Smart Monitoring System compact, secure, efficient

Smart Monitoring System compact, secure, efficient Smart Monitoring System compact, secure, efficient Transparency for more efficiency Continuously record and monitor the energy consumption of plant and machinery Visualise data on a display or through

More information

FI Server Range. 600mm Wide 800mm Wide Door Options

FI Server Range. 600mm Wide 800mm Wide Door Options TM FI Server Range 600mm Wide 800mm Wide Door Options The Fi server cabinet range was designed by our in-house team of engineers to meet the needs of today s high density data centre installations. The

More information

Refrigerated incubators with forced convection

Refrigerated incubators with forced convection KB series (E3.1) Incubators Refrigerated incubators with forced convection The most versatile incubator for microorganisms: The BINDER KB series controls a temperature range of -5 C to 100 C. With its

More information

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional

More information

5. Office furniture. 5. Office furniture. Laboratory furniture. Flexible and customised

5. Office furniture. 5. Office furniture. Laboratory furniture. Flexible and customised 5. Office Flexible and customised 5. Office Laboratory Your laboratory staff needs a thoughtfully planned office or work area and we have just the you have been looking for. Functional and customised to

More information

VERTIV KNÜRR SPECIAL CATALOG. Networks & Data Centers

VERTIV KNÜRR SPECIAL CATALOG. Networks & Data Centers VERTIV KNÜRR SPECIAL CATALOG Networks & Data Centers Vertiv Vertiv designs, builds and services mission critical technologies that enable the vital applications for data centers, communication networks,

More information

Varistar Data/Network Systems

Varistar Data/Network Systems Varistar Data/Network Systems Varistar Datacom /NetworkingMAIN CATALOG Cabinets OVERVIEW MAIN KATALOG Cabinets....... 1 Wall mounted cases......... 2 Accessories for cabinets and wall mounted cases.. 3

More information

CPCI System Subrack 3 U

CPCI System Subrack 3 U User s Manual Product No.: Doc-No: 63972-227_R1.1 April 18, 2011 Rev. Date updated Change R1.0 January 14, 2008 Initial Release R1.1 April 18, 2011 Fan Tray with mini compression latch Impressum: Schroff

More information

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks 19-inch Industry Standard Rack Systems The trend to consolidation as a result of virtualization and optimization

More information

Take a really close look Quality and compatibility play a superior role in integrated systems and infrastructures we can stand up to closer scrutiny

Take a really close look Quality and compatibility play a superior role in integrated systems and infrastructures we can stand up to closer scrutiny Take a really close look Quality and compatibility play a superior role in integrated systems and infrastructures we can stand up to closer scrutiny DIGITUS Professional defines a clear benchmark for the

More information

OZLINX Solutions Australia Pty Ltd 21 Ayton Street, Sunshine North, Melbourne VIC3020 Australia Ph: Fax:

OZLINX Solutions Australia Pty Ltd 21 Ayton Street, Sunshine North, Melbourne VIC3020 Australia Ph: Fax: OZLINX Solutions Australia Pty Ltd 21 Ayton Street, Sunshine North, Melbourne VIC3020 Australia Ph: +61 3 93102440 Fax: +61 3 93102441 www.ozlinx.com OZLINX Cabinets OZLINX Cabinets OZLINX cabinets combine

More information

Rittal LCP T3+ High-availability IT cooling with no compromise

Rittal LCP T3+ High-availability IT cooling with no compromise Rittal LCP T3+ High-availability IT cooling with no compromise LCP T3+, the climate for maximum availability... in the financial world Admittedly, we have no solution for overheated markets. But we do

More information

LCP Hybrid Efficient performance with heat pipe technology

LCP Hybrid Efficient performance with heat pipe technology LCP Hybrid Efficient performance with heat pipe technology 2 LCP Hybrid The whole is more than the sum of its parts The same is true of "Rittal The System." With this in mind, we have bundled our innovative

More information

Vertiv VR Rack 1.0 GENERAL

Vertiv VR Rack 1.0 GENERAL 1.1 SUMMARY Vertiv VR Rack Guide Specifications 1.0 GENERAL This specification defines the mechanical characteristics and requirements for the Vertiv VR Rack. A series of adaptive and scalable electronic

More information

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation Luminato Installation Manual Teleste Corporation Mounting Instructions Mechanical Mounting Luminato Mechanical Installation, agile_59300316, rev0044 Introduction 1 Contents Introduction 4 General... 4

More information

THE ART OF SUCCESSFUL MERCHANDISE Professional information and communication with OCTANORM Display Systems. presentation systems

THE ART OF SUCCESSFUL MERCHANDISE Professional information and communication with OCTANORM Display Systems. presentation systems THE ART OF SUCCESSFUL MERCHANDISE Professional information and communication with OCTANORM Display Systems presentation systems AESTHETIC PRESENTATION AS A DESIGN PRINCIPLE Attract attention at your event,

More information

SYSTIMAX Rack and Cabinet Solution

SYSTIMAX Rack and Cabinet Solution SYSTIMAX Rack and Cabinet Solution The SYSTIMAX Rack and Cabinet Solution offer is designed for use in telecommunications equipment installations, providing our SYSTIMAX BusinessPartners and customers

More information

or

or Infinite possibilities for your data center The F-Series TeraFrame T M Cabinet System The F-Series TeraFrame Cabinet System from Chatsworth Products, Inc. (CPI) provides configurable thermal management

More information

ABINETS - FREE STANDING TYPE 19 ESTAP DATA RACK REE STANDING TYPE FIBER TERMINATION BOXES

ABINETS - FREE STANDING TYPE 19 ESTAP DATA RACK REE STANDING TYPE FIBER TERMINATION BOXES ABINETS - FREE STANDING TYPE 19 ESTAP DATA RACK WHO WE ARE ESTAP ELECTRONIC PACKAGING company has been a major force in the Turkey electronics enclosures industry since 1989. The company offers a comprehensive

More information

707 Patching Frames. 505 Frames. 303 Frames. 404 & 202 Wallboxes. 505 Cabinets. 303 Cabinets. Cold Aisle Containment. 505 Server Cabinets

707 Patching Frames. 505 Frames. 303 Frames. 404 & 202 Wallboxes. 505 Cabinets. 303 Cabinets. Cold Aisle Containment. 505 Server Cabinets 303 Frames 505 Frames 707 Patching Frames 303 Cabinets 505 Cabinets 404 & 202 Wallboxes Standard Aisle Configuration 30 oc 40oc 30 oc 22 oc 22 oc 17 oc Cold Aisle 25 oc Hot Aisle 17 oc Cold Aisle Cold

More information

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE The Omega MPP enclosure is based on a 19" frame, with 4 empty module slots for MPP modules. Highly flexible : any mix between twisted pair and optical fiber modules.

More information

Content. - Equipment/Racks - Open System Racks - ODF/ MMF/ DDF Frames - Outdoor Equipment Cabinets - Customized Racking

Content. - Equipment/Racks - Open System Racks - ODF/ MMF/ DDF Frames - Outdoor Equipment Cabinets - Customized Racking Content 1.1 Racking System 1.1.0 Overview 3 4 1.2 19 Equipment Racks 5 1.3 19 Cable Management Rack 6 1.4 Open System Rack 7 1.5 Outdoor Cabinet 1.5.1 TSM Outdoor Cabinet 1.5.2 DLC Outdoor Cabinet 8 9

More information

RiMatrix S Make easy.

RiMatrix S Make easy. RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power

More information

VME Subrack System 7 U

VME Subrack System 7 U User Manual Product Numbers: 20836-715 20836-718 Doc-No: 63972-148 Revision: R1.1, November 14, 2008 Rev. Date updated Change R1.0 August 22, 2006 Initial Release R1.1 November 14, 2008 Part no. FCM added

More information

Rittal KVM technology

Rittal KVM technology Rittal KVM technology Perfect Server Administration R PERFECT SERVER ADMINISTRATION WITH KVM TECHNOLOGY FROM RITTAL Rittal KVM (Keyboard Video Mouse) switches provide the perfect answer for every customer

More information

Knürr Elicon Ergonomic. Modular. Future-proof. Control Room Infrastructure

Knürr Elicon Ergonomic. Modular. Future-proof. Control Room Infrastructure Knürr Elicon Ergonomic. Modular. Future-proof Control Room Infrastructure Knürr Elicon Knürr Elicon VC and VC-E Series 4 Modular Workstation Systems Knürr Elicon Classic 14 Knürr Elicon Accessories 22

More information

3/4 U CPCI Serial Case System

3/4 U CPCI Serial Case System 3/4 U CPCI Serial Case System User s Manual Product Number: 4579-634 Doc-No: 6397-345_R.0 October 05 R.0 October 05 Initial Release Impressum: Schroff GmbH Langenalber Str. 96-00 75334 Straubenhardt, Germany

More information

3+1 U CPCI Serial System

3+1 U CPCI Serial System 3+ U CPCI Serial System User s Manual Product Number: 4579-46/47/48/49/40/4/4/43/44 Doc-No: 6397-349_R.0 January 06 R.0 January 06 Initial Release Impressum: Schroff GmbH Langenalber Str. 96-00 75334 Straubenhardt,

More information

nls Product List 1st February, 2014 Tel: Fax: Coombes Drive, Penrith, NSW, 2750 Australia

nls Product List 1st February, 2014 Tel: Fax: Coombes Drive, Penrith, NSW, 2750 Australia 15 Coombes Drive, Penrith, NSW, 2750 Australia 15 Coombes Drive Penrith NSW 2750 Tel: 02-4732 5444 Fax: 02-4732 6600 Email: sales@nlslight.com.au Product list for Electrical Accessories Code Item Inner

More information