The bodyguards. Current relay, mains monitoring relay, currentlimiting relay and mains disconnection relay

Size: px
Start display at page:

Download "The bodyguards. Current relay, mains monitoring relay, currentlimiting relay and mains disconnection relay"

Transcription

1 Current relay, mains monitoring relay, currentlimiting relay and mains disconnection relay The bodyguards G Selection table bodyguards Current relay AR12NP Mains monitoring relay NR12 Current-limiting relay SBR12 and SBR61 Self-learning mains disconnection relay FR12 Self-learning mains disconnection relay FR61 and accessory base load GLE Technical data and phase annunciator P3K12 G0 G1 G2 G3 G4 G5 G6 Switching on the future.

2 Selection table current relay, mains monitoring relay, current-limiting relay and mains disconnection relay The bodyguards ELTAKO mains disconnection relays switch off a monitored 230V conductor after connected loads are switched off manually. This prevents interfering electromagnetic alternating fi elds. A DC voltage with an extremely low residual ripple is used for monitoring purposes. No measurable alternating fi eld is generated but it is guaranteed that room lighting is detected when switched on. The monitored conductor is then switched on again. Electronically controlled loads or supplied loads, require a high degree of monitoring effort. Here, the self-learning mains disconnection relays are ideal for such applications. Page G1 G2 G2 G3 G3 G4 G5 G6 pictograms AR12NP-230V NR x230V NR x230V SBR12-230V/240 μf SBR V/120 μf FR12-230V FR61-230V P3K12 Modular device for mounting on DIN rail EN 50022, number of modules 18mm each Built-in device for installation (e.g. fl ush-mounting box) and surface mounting G0 Number NO contacts or CO contacts potential free (not potential free) Zero passage switching (1W) 1W 2W 1 1 (1) (1) Switching capacity 16A/250V AC Switching capacity 10A/250V AC Incandescent lamp load W Fluorescent lamp load with EVG* and energy saving lamps W Ion <_70A/ 10ms 1) Ion <_70A/ 10ms 1) Ion <_70A/ 10ms 1) Ion <_70A/ 10ms 1) Supply voltage 230V No standby loss Low standby loss Current relay Mains monitoring relay Current-limiting relay Mains disconnection relay Phase annunciator *EVG = electronic ballast units 1) A 40-fold inrush current must be expected for electronic ballast devices. Limit with SBR12 or SBR61 if applicable.

3 Current relay AR12NP AR12NP-230V 1 CO contact not potential free 16A/250V AC. Standby loss 0.8 watt only. Function rotary switches module=18mm wide, 58mm deep. With an internal toroidal-core current transformer the single phase AC current flowing through a consumer V1 of 0.1A up to max. 32A is compared to the setpoint. When the latter is exceeded a special relay with high capacity switches off a consumer V2 connected to 2 within 0.5 seconds or switches on a consumer V3 connected to 3. Adjustment accuracy ±5%. From 25A the relay always switches on. Zero passage switching to protect contacts and consumers. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The basis of current A will be set with the lower rotary switch A. The following basic values can be selected: 0.1A, 0.3A, 0.6A, 0.9A,1.5A,1.9A, 3.0A and 3.2A. The multiplier xa will be set with the middle rotary switch xa and offers values between 1and 10. So currents starting from 0.1A (basis of current 0.1A and multiplier 1) can be set. OFF delay RV can be set with the upper rotary switch RV between 0 and 120 secs. The hysteresis is defined as approx. 25%. Status indication by LED. The measuring input M1-M2 is electrically isolated from power supply L-N and make contact L-2/3. Reference values larger than 32 A can be adapted by an external measuring transformer. Standard setting ex factory. G1 Technical data page G6. Housing for operating instructions GBA12 page Z2. AR12NP-230V 1 CO 16 A EAN Recommended retail prices excluding VAT.

4 Mains monitoring relays NR12 monitoring the rotating field NR x230 V 1 CO contact potential free 10A/250V AC. Standby loss 0.8 watt only. Function rotary switches 1 module=18mm wide, 58mm deep. Designed to monitor 230V AC voltage between 1 to 3 phase conductors and neutral and to monitor the rotating field (clockwise) in the switch positions 2Ph and 3Ph. In the position only the rotating field is monitored, independent from the mains voltage. Supply voltage L1-N V/50-60Hz. In case of failure of L1 the relay releases immediately without delay. With the lower rotary switch on the front two operate voltages resp. dropout voltages can be set and the number of monitored phase conductors must be selected. U1: 161V dropout voltage and 185V operate voltage. U2: 196V dropout voltage and 206V operate voltage as per VDE 0100, part 718 (formerly: VDE 0108, part 1). Voltage applied signalled by LED. At wrong polarity or in case of a missing phase conductor the LED flashes rapidly. Release delay RV settable with the upper rotary switch from 0.1 to 8sec. The LED flashes slowly during the release delay time period. Operate delay 0.5 sec. Maximum fusing 16 A. Technical data page G6. Housing for operating instructions GBA12 page Z2. NR x230V 1 CO 10 A EAN G2 NR x230V 2 CO contacts potential free 10A/250V AC. Standby loss 0.8 watt only. 2 modules=32mm wide, 58mm deep. All functions same as NR x230 V but with a second NO contact. Maximum fusing 16 A. Technical data page G6. Housing for operating instructions GBA12 page Z2. s: 1 phase monitoring 3 phase monitoring NR x230V NR x230V NR x230V NR x230V NR x230V 2 CO 10 A EAN Recommended retail prices excluding VAT.

5 Current-limiting relays capacitive SBR SBR12-230V/240 F 1 NO contact 16A/250V AC. No standby loss. local ON/OFF check back signal 1 module=18mm wide, 58mm deep. Max. capacitive load 240μF downstream of rectifier (e.g. energy saving lamps and electronic ballast) or 120μF directly at the mains (e.g. shunt-compensated fluorescent lamps). Limiting resistor 12, limiting period approx. 15msec. The starting current impulse of energy saving lamps, fluorescent lamps and compact fluorescent lamps is limited to 20A by short-time switch-on (approx. 15 msec.) of heavy-duty resistors (12). The current-limiting relay is connected on the load side of the protected relay contact. Permanent load max W, max. switching frequency 600/ h. Explanation of capacitive load specification: The specified max. capacitive load directly at the mains is the deciding factor determining shunt-compensated fluorescent lamps or conventional ballast, for example. Here the capacitor switched in parallel to the mains is the deciding factor determining the correct dimensioning per lamp. The specified max. capacitive load downstream of the rectifier is the deciding factor determining fluorescent lamp ballast or energy saving lamps, for example. An equivalent capacitance of 10μF per lamp may be calculated. ESR12M or ES12Z with SBR V/240 μf SBR12-230V/240μF 1 NO 16 A EAN G3 SBR61-230V/120 F 1 NO contact 10A/250V AC. No standby loss. Built-in device for installation and surface mounting 45mm long, 55mm wide, 18mm deep. Max. capacitive load 240μF downstream of rectifier (e.g. energy saving lamps and electronic ballast) or 120μF directly at the mains (e.g. shunt-compensated fluorescent lamps). Limiting resistor 24, limiting period approx. 15ms. The starting current impulse of energy saving lamps, fluorescent lamps and compact fluorescent lamps is limited to 10A by short-time switch on (approx. 15 msec.) of heavy-duty resistors (24). The current-limiting relay is connected on the load side of the protected relay contact. Permanent load max. 600 W, max. switching frequency 600/h. Explanation of capacitive load specification: The specified max. capacitive load directly at the mains is the deciding factor determining shunt-compensated fluorescent lamps or conventional ballast, for example. Here the capacitor switched in parallel to the mains is the deciding factor determining the correct dimensioning per lamp. The specified max. capacitive load downstream of the rectifier is the deciding factor determining fluorescent lamp ballast or energy saving lamps, for example. An equivalent capacitance of 10μF per lamp may be calculated. SBR61-230V/120μF 1 NO 10A EAN Recommended retail prices excluding VAT..

6 Self-learning mains disconnection relay FR12 FR12-230V V G4 Rotary switches Standard setting ex factory. monitored circuit 1 NO contact not potential free 16A/250V AC. Incandescent lamp load 2300W. Standby loss 0.8 watt only. Modular device for DIN EN rail mounting. 1 module =18mm wide and 58mm deep. 230 V supply voltage and switching voltage. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The FR12-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring. Small loads up to 200mA, are acceptable and, once major loads are disconnected, they do not prevent field disconnection. There is no need to manually set the limit; it is learned by the FR12. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected. As long as no major load is turned on, one pole of the monitored circuit remains isolated from the mains. Neutral and earth are connected continuously to avoid acting as an aerial. A DC voltage with an extremely low residual ripple is applied for monitoring. Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure. When a load is turned on, the mains disconnection switch connects the monitored phase after approx. 1 sec and the LED lights red. Function of the lower rotary switch In the function ON/ position, the relay contact is continuously closed and field disconnection deactivated. Turn the switch to the position A = automatic with 'self-learn mode', the actual current value is saved as a switch-off value. When this value is reached, the FR12 breaks the electrical circuit regardless whether small consumers such as electronic dimmers are connected. Therefore, the lighting must always be OFF for learning by means of the rotary switch. When the switch is in the A position the FR12 adapts to changes in connected consumers. The FR12 performs a new learn-in routine after phase is activated and when the power supply is restored after a power failure. If a new small load is switched on for more than 24 hours, the total current drawn by the monitored circuit is less than 200mA, the FR12 is set to A mode and in the meantime the light has been switched on and off, the new load is learned in and the conductor is switched off. When the rotary switch is set briefly from A to, learn-in takes place immediately after connecting a new load. If the function self-learn is not required, set the rotary switch to A automatic OFF. Function of the upper rotary switch The monitoring voltage can be adjusted in the range from 5V DC to 230V DC. Due to its low residual ripple, it generates no measurable alternating field even at 230V DC. The higher the adjustment, the greater the number of capacitive loads detectable without switching on a base load. It can therefore be reduced until the loads are barely detectable. In many applications, even the lowest monitoring voltages are detectable. Technical data page G6. Housing for operating instructions GBA12 page Z2. FR12-230V 1 NO 16 A EAN Recommended retail prices excluding VAT.

7 Self-learning mains disconnection relay FR61, accessory base load FR V 1 NO contact not potential free 10A/250V AC. Standby loss 0.8 watt only. Side view monitored circuit Built-in device for installation and surface mounting 45mm long, 55mm wide, 26mm deep. 230 V supply voltage and switching voltage. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The FR61-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring. Small loads up to 20mA are acceptable and, once major loads are disconnected, they do not prevent field disconnection. There is no need to manually set the limit; it is learned by the FR61. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected. As long as no major load is turned on, one pole of the monitored circuit remains isolated from the mains. Neutral and earth are connected continuously to avoid acting as an aerial. A DC voltage of 230V DC with an extremely low residual ripple is applied for monitoring. Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure. When a load is turned on, the mains disconnection relay connects the phase. If the phase is switched on for the first time and after a power failure the FR61 automatically learns in again: At first an inrush current of 30mA is specified. If a new small load is switched on for more than 24 hours, the total current drawn by the monitored circuit is less than 200mA, and in the meantime the light has been switched on and off, the new load is learned in and the conductor is switched off. This learn-in mode can be realised immediately after connection of the new load by briefly switching off the MCB. G5 Technical data page G6. FR61-230V 1 NO 10 A EAN GLE Accessory base load A base load is used if loads cannot be detected due to their capacitance but are meant to switchon the line voltage. Base loads must consistently start or operate in parallel with the related loadand be turned off with the latter. Higher stand by loads may affect or jam the detection of a base load. Typical applications: Fluorescent lamps, dimmer circuits and electronic transformers. GLE base load element PTC in a small coupler with connecting leads; can be used directly in a load, a switch box or a junction box. It is not capable of keeping the mains disconnection relay in the connected state without an additional load connected. GLE 1x base load EAN Recommended retail prices excluding VAT.

8 Phase annunciator P3K12 and technical data current relay, mains monitoring relay and mains disconnection relay P3K12 Phase annunciator. Standby loss 0,06 watt only. 1 module = 18mm wide, 58mm deep. For visual monitoring of 1 to 3 phases 230V. Indication with three red LEDs. P3K12-230V EAN Technical data Contacts NR12 AR12NP/FR12 FR61 Contact material AgSnO 2 /0.5mm AgSnO 2 /0.5mm AgSnO 2 /0.5mm Spacing of control connections/contact > 6mm, AR12NP: > 6mm Test voltage contact to contact Test voltage control connection to contact, NR12-002: 2000 V 4000 V, AR12NP: 4000 V Rated switching capacity 10 A/250 V AC 16 A/250 V AC 10 A/250 V AC G6 Incandescent lamp and halogen lamp load 1) 230V 2000W 2300W 1000 W Fluorescent lamp load with KVG* in lead-lag circuit or non compensated 1000 VA 1000 VA 1000 VA Fluorescent lamp load with KVG* shunt-compensated or with EVG* 500 VA 1000 VA 500 VA Compact fl uorescent lamps with EVG* and energy saving lamps ESL I on <_ 70A/ 10ms 2) I on <_ 70A/10ms 2) AR12NP: 15x7W, 10x20 W Max. switching current DC1: 12V/24V DC 8A I on <_ 70A/ 10ms 2) Life at rated load, cos = 1 at 100/h > 10 5 >10 5 >10 5 Life for incandescent lamps 1000W at 100/h > 10 5 >10 5 >10 5 Life at rated load, cos = 0.6 at 100/h > 4 x10 4 > 4 x10 4 > 4 x10 4 Max. operating cycles 10 3 /h 10 3 /h 10 3 /h Switching position indication/ voltage indication LED LED Terminal cross-section 12 mm 2 12 mm 2 clamping screw M3 Maximum conductor cross-section 6 mm 2 6mm mm 2 Screw head slotted/ Phillips, pozidriv slotted/ Phillips, pozidriv slotted Shock-hazard protection (on the device) VDE 0106 part 100 VDE 0106 part 100 VDE 0106 part 100 Electronics Time on 100% 100% 100% Max./min. temperature at mounting location +50 C/-20 C +50 C/-20 C +50 C/-20 C Control voltage range V/50-60Hz 0.9 to 1.1xrated voltage 0.9 to 1.1xrated voltage Stand by loss (active power) 0.8 W 0.8 W 0.8 W Max. parallel capacitance (length) of control lead 0.06 μf (200m) 0.06 μf (200m) 0.06 μf (200m) *EVG = electronic ballast units; KVG = conventional ballast units 1) Applies to lamps with max. 150W. 2) A 40-fold inrush current must be expected for electronic ballast devices. Compliance with: EN , EN and EN 60669

The Energy Savers. Universal dimmer switches, capacity enhancer and 1-10V controllers. Selection table for universal dimmer switches,

The Energy Savers. Universal dimmer switches, capacity enhancer and 1-10V controllers. Selection table for universal dimmer switches, Universal dimmer switches, capacity enhancer and 1-10V controllers B The Energy Savers Selection table for universal dimmer switches, capacity enhancer and 1-10V controllers B0 Universal dimmer switch

More information

Make a confident stride through the stairwell with Eltako staircase time switches

Make a confident stride through the stairwell with Eltako staircase time switches 15 Make a confident stride through the stairwell with Eltako staircase time switches 15 Staircase time switches and off-delay timers Selection table staircase time switches and off-delay timers 15-2 Staircase

More information

Time relays, Multifunctions time relay and timer. Up to 18 functions combined with universal control voltage an unrivalled combination.

Time relays, Multifunctions time relay and timer. Up to 18 functions combined with universal control voltage an unrivalled combination. 13 Time relays, Multifunctions time relay and timer. Up to 18 functions combined with universal control voltage an unrivalled combination. 13 Time relays, multifunction time relays and timer Selection

More information

The Energy Savers. Universal Dimmer Switches, capacity enhancer and 1-10V controllers. Selection table for universal dimmer switches,

The Energy Savers. Universal Dimmer Switches, capacity enhancer and 1-10V controllers. Selection table for universal dimmer switches, Universal Dimmer Switches, Capacity Enhancer and 1-10V Controllers B The Energy Savers Selection table for universal dimmer switches, capacity enhancer and 1-10V controllers B0 Universal dimmer switch

More information

Products and prices 2011

Products and prices 2011 1949 2011 YEARS OF INNOVATION Products and prices 2011 Switchgear, power supply units and electronic energy meters for installation in buildings and use in control technology Switching on the future 05/2011

More information

Eltako Powerline The ideal supplement to the Eltako Wireless Building System with EnOcean

Eltako Powerline The ideal supplement to the Eltako Wireless Building System with EnOcean 14 Eltako Powerline The ideal supplement to the Eltako Wireless Building System with EnOcean 4 Eltako Powerline 4-1 Wireless Powerline gateway FPLG14 and Wireless Powerline Tunnel Gateway FPLT14 4-2 Powerline

More information

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED Art. no.: 1731DD Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please

More information

The LED display (1) turns green when the load is switched on.

The LED display (1) turns green when the load is switched on. Order no.: 2365 00 Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible.

More information

Product and functional description

Product and functional description Product and functional description The UP 525/13 Universal Dimmer is a KNX device with one dimmer output. The device is installed in a flushmount wall box (60 mm Ø, depth 60 mm) or an installation box.

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.: Extract from the online catalog MINI-DC-UPS/12DC/4 Order No.: 2866598 Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah Commercial

More information

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011 , 2CDG 110 15x R0011 SA/S 12.6.1.1 2CDC 071 033 S0012 The 6 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are suitable for

More information

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in prom design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

QUINT-PS AC/24DC/10

QUINT-PS AC/24DC/10 Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

Operating voltage Maximum

Operating voltage Maximum , 2CDG 110 0x R0011 2CDC 071 023 F000 The ABB i-bus Light Controllers, (x = 2 or 4) are KNX modular installation devices in ProM Design for installation in the distribution board on 35 mm mounting rails.

More information

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005 Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program

More information

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. , GH Q631 0047 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. Using eight floating contacts, it switches

More information

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , , LINEAR LED DRIVERS PrimeLine DALI DIMMABLE 186445, 186446, 186575, 186576, 186577, 186578 Linear LED drivers with preset operating window or individual programming Typical Applications Built-in in linear

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/ 1AC/24DC/ 5 Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)

More information

PHOENIX CONTACT - 01/2007

PHOENIX CONTACT - 01/2007 Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer submodule N 528/41 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus 4.7 Digital Input/Output Module 16 digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 4 V DC, CS31 system bus 1 3 Advant Controller 31 I/O Unit ERR Test 4 1 Fig. 4.7-1: Digital input/output

More information

Figure 1: Device components

Figure 1: Device components , switch function, push-button function Art.-No.: 240-31 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe

More information

OPTIMISED LUMINAIRE PROTECTION

OPTIMISED LUMINAIRE PROTECTION OPTIMISED LUMINAIRE PROTECTION LUMINAIRE PROTECTION AND POWER ADJUSTMENT This chapter presents inrush current limiters, electronic components to protect luminaires against mains surges, power reduction

More information

Solid State Remote Power Controller E /627

Solid State Remote Power Controller E /627 Solid State Remote Power Controller E--623/62 Description The E-T-A Solid State Remote Power Controllers E--623/62 are electronic control modules suitable for inductive loads such as electromagnetic valves

More information

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX Gamma instabus Technical Product nformation Switching Actuators N53, 6AX Switching Actuators N532, 1AX Switching Actuators N534, 16/2AX 4x AC 23V 5WG1 53-1DB31 5WG1 532-1DB31 5WG1 534-1DB31 8x AC 23V 5WG1

More information

COMPACT LED CONVERTERS 48 V

COMPACT LED CONVERTERS 48 V COMPACT LED CONVERTERS 48 V EasyLine 48 V 186691, 186692 Typical Applications Shop lighting for 48 V systems Furniture lighting EasyLine 48 V VERY COMPACT SHAPE VERY LOW RIPPLE CURRENT LONG SERVICE LIFETIME:

More information

OPTIMISED LUMINAIRE PROTECTION

OPTIMISED LUMINAIRE PROTECTION OPTIMISED LUMINAIRE PROTECTION LUMINAIRE PROTECTION AND POWER ADJUSTMENT This chapter presents inrush current limiters, electronic components to protect luminaires against mains surges, power reduction

More information

XE2 DC current relay for loss of excitation protection. Manual XE2 (Revision A)

XE2 DC current relay for loss of excitation protection. Manual XE2 (Revision A) XE2 DC current relay for loss of excitation protection Manual XE2 (Revision A) Woodward Manual XE2 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.

More information

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations

More information

High-performance switching actuators

High-performance switching actuators High-performance switching actuators Wide-ranging applications efficient installation and set-up operation for many years The worldwide standard for home and building control siemens.com/gamma Switching

More information

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors

More information

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011 Technical Data 2CDC505054D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.6.2.1, 10 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

Technical advantages. universal: - the choice of fitting or light source can be made afterwards

Technical advantages. universal: - the choice of fitting or light source can be made afterwards 8 ighting control ighting control More atmosphere The time when lighting control was simply switching the lights on and off is long gone. owadays, lighting control is creativity. With the iko lighting

More information

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New)

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New) XU1-E Earth fault voltage relay (August 1996) Manual XU1-E (Revision New) Woodward Manual XU1-E GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both

More information

ISOMETER isopv with coupling device AGH-PV

ISOMETER isopv with coupling device AGH-PV Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) for photovoltaic plants up to AC 793 V/DC 1100 V Vorläufiges Datenblatt IsoPV_D00024_02_D_XXEN/07.2018 ISOMETER with coupling

More information

picture 1: Device components

picture 1: Device components Tronic rotary dimmer with soft-lock Order-No. : 2874 Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161 Technical Data 9AKK107045A4913 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD KNX Product documentation Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD Issue: 19.12.2012 Page 1 of 153 KNX Product documentation Contents 1 Product

More information

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection 4.8 Digital Input/Output Module 07 DC 9 3 configurable digital inputs/outputs, 4 V DC, electrically isolated in groups, outputs can be loaded with 500 ma, CS31 system bus 1 3 4 1 Fig. 4.8-1: Digital input/output

More information

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , , COMPACT LED DRIVERS EasyLine SIMPLE FIX 186719, 186720, 186721, 186722, 186723, 186724, 186725, 186726, 186727, 186728 Typical Applications Built-in in compact luminaires Shop lighting Downlights EasyLine

More information

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) COMPACT LED DRIVERS PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) 186762, 186763 Typical Applications Built-in in compact luminaires Shop lighting Downlights PrimeLine DALI dimmable & Selectable

More information

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/20 Order No.: 2866381 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 20 A Commercial data EAN 4046356046664 Pack 1 pcs. Customs

More information

Extension module for lighting control

Extension module for lighting control s 3 842 DESIGO RXC Extension module for lighting control Extension to the RXC30 / RXC31 / RXC38 room controller RXC40.1 RXC40.5 The RXC40 extension module is used in conjunction with an RXC30, RXC31 or

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/ Guangzhou Video-star Electronics Industrial Co., Ltd K-BUS R Dimming Actuators User manual-ver. 4 KA/D 0103.1 KA/D 0203.1 KA/D 0403.1 KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/03.1...... KNX/EIB Intelligent

More information

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual Control unit 1-10 V, 3-gang Art.-No.: 2193 REG Operationsmanual 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions

More information

Features, Benefits and Functions

Features, Benefits and Functions .5-44 September 2011 Sheet 084 PSG Series DC Power Supplies PSG Series General Description Eaton s PSG Series of power supplies is designed to be a high-performance, high-quality line of products covering

More information

QUINT-PS/ 1AC/24DC/20/CO

QUINT-PS/ 1AC/24DC/20/CO Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective

More information

LUNA LUNA 111 top2 LUNA 112 top2 D GB F I E P , , Assembly and operating instructions Digital twilight switch

LUNA LUNA 111 top2 LUNA 112 top2 D GB F I E P , , Assembly and operating instructions Digital twilight switch 2 2 309 271 01 LUNA LUNA 111 top2 LUNA 112 top2 111 0 100, 111 0 200 112 0 100, 112 0 200 Ext L N Data + 4 5 6 C2 Ext1 Ext2 L N Data + GB Assembly and operating instructions Digital twilight switch MENU

More information

CC COMPACT DIP SWITCH

CC COMPACT DIP SWITCH CC COMPACT DIP SWITCH COMFORTLINE DIP SWITCH C-R5 186841, 186842, 186843 Typical Applications Built-in in compact luminaires for Shop lighting Downlights Panels ComfortLine DIP switch C-R5 SELECTABLE OUTPUT

More information

COMPACT LED DRIVERS. EasyLine Selectable Current (Output Terminal) EasyLine SELECTABLE CURRENT (OUTPUT TERMINAL) , , ,

COMPACT LED DRIVERS. EasyLine Selectable Current (Output Terminal) EasyLine SELECTABLE CURRENT (OUTPUT TERMINAL) , , , COMPACT LED DRIVERS EasyLine SELECTABLE CURRENT (OUTPUT TERMINAL) 186463, 186464, 186531, 186532 Typical Applications Built-in in reflector luminaires Shop illumination Downlights EasyLine with selectable

More information

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , , COMPACT LED DRIVERS ComfortLine RESIDENTIAL 186679, 186680, 186681, 186682 Typical Applications Built-in in compact luminaires for Residential lighting Downlights ComfortLine Residential VERY COMPACT SHAPE

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011 Technical Data 2CDC505082D0203 ABB i-bus KNX Product description Switch Actuators SA/S x.16.6.1, 16/20 A are modular installation devices in ProM design for installation in the distribution board. They

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide

More information

Product and functional description

Product and functional description Product and functional description The instabus / DAI gateway 141 is a KX EIB device with one DAI output to which up to 64 DAI actuators (e.g. DAI ballasts) can be connected to. It is not allowed to connect

More information

Power Supply HARTING pcon

Power Supply HARTING pcon HARTING pcon 2060 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)

More information

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter

More information

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , COMPACT LED DRIVERS EasyLine SIMPLE FIX 186591, 186592, 186593, 186594, 186595, 186669 Typical Applications Built-in in or independent version for Shop lighting Downlights EasyLine with fixed output current

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , LINEAR LED DRIVERS EasyLine SIMPLE FIX 186712, 186713, 186714, 186715, 186716, 186760 Typical Applications Built-in in linear luminaires for Office lighting Weatherproof Luminaires EasyLine Simple Fix

More information

11 Series - Light Dependent Relay A. Features pole 17.5 mm wide. 1 pole zero hysteresis 4 position selector

11 Series - Light Dependent Relay A. Features pole 17.5 mm wide. 1 pole zero hysteresis 4 position selector Features 11.31 11.41 Relays for automatic control of lighting according to ambient light level - with separate light sensor 11.31-1 NO 16 A output contact Sensitivity adjustment from 1 to 100 lux One module,

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Highly Reliable and Full-functioned 1-year Life Expectancy, 12, 1, or 24 V output voltages, and 30, 60, 0, or 10 W power ratings. 8 to 132 VAC or 170 to 264 VAC switchable input

More information

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions Control unit, 1-10 V 3-gang Order-No. : 1019 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the

More information

Datasheet SRB301ST 24V (V.2)

Datasheet SRB301ST 24V (V.2) 26.10.2016 05:03:31h Datasheet SRB301ST 24V (V.2) Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301ST Suitable

More information

1.5 Solid State Relays

1.5 Solid State Relays Relays.. Solid State Relays Application s Pins Contacts AC ratings DC ratings Socket CSS Series AC Solid state, Instantaneous switching CSS-I A / 0 V S0 AC Solid state synch. to zero crossing CSS-Z A /

More information

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-REL(-SP) Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.

More information

Signal Doublers. VariTrans A 20300

Signal Doublers. VariTrans A 20300 ProLine Interface Technology Signal Doublers Signal doublers with two switchable calibrated outputs in a 6 mm housing, also for applications with high output loads. The Task Isolation and transmission

More information

RTU500 series Data Sheet Power Supply CP-E 24/2.5

RTU500 series Data Sheet Power Supply CP-E 24/2.5 Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped

More information

Residual Current Devices drcm Digital

Residual Current Devices drcm Digital Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.

More information

Power supply CP-E 24/0.75 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply Data sheet Power supply CP-E 24/0.75 Primary switch mode power supply The CP-E range offers enhanced functionality while the number of different types has been considerably reduced. Now all power supply

More information

Test devices and Multifunction timer relay

Test devices and Multifunction timer relay Test devices and Multifunction timer relay VARIOTEST ROTATEST CSG420 Test devices Industries VARIOTEST The Condor-VARIOTEST is a universal test instrument featuring acoustic signals for: P. 145 Testing

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

S 180 OPTICAL AND AUDIBLE MODULAR DEVICES. This is our idea that lead us to create and engineering this modular lamp. MODULAR CONFIGURATION

S 180 OPTICAL AND AUDIBLE MODULAR DEVICES. This is our idea that lead us to create and engineering this modular lamp. MODULAR CONFIGURATION S 180 OPTICAL AND AUDIBLE MODULAR DEVICES S180 a custom made lamp This is our idea that lead us to create and engineering this modular lamp. custom solutions keeping minimized costs and stock 10 different

More information

Rev Operating Instructions Busch-Dimmer. Potentiometer U-101

Rev Operating Instructions Busch-Dimmer. Potentiometer U-101 1473-1-7906 Rev. 01 17.12.2012 Operating Instructions Busch-Dimmer Potentiometer 2112-101 2112 U-101 Busch-Dimmer 1 Safety... 3 2 Intended use... 3 3 Environment... 3 4 Technical data... 4 5 Setup and

More information

LDD M SERIES INSTRUCTION MANUAL LDD M SERIES

LDD M SERIES INSTRUCTION MANUAL LDD M SERIES TM LDD M SERIES LDD M SERIES INSTRUCTION MANUAL P O Box Bozeman, MT 9 Phone (0) -90 Fax (0) -9 email sales@wavelengthelectronics.com www.wavelengthelectronics.com TABLE OF CONTENTS Features... Customer

More information

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide Control Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed

More information

As soon as the luminaires are switched off, the built-in relay disconnects the control gear from the mains supply, reducing power loss to 0.5 W.

As soon as the luminaires are switched off, the built-in relay disconnects the control gear from the mains supply, reducing power loss to 0.5 W. luxcotro smartdim Control with ambient light sensor/push to make switches/pir sensor Digital DSI sensor module for controlling 5 digital, electronic ballasts. By connecting a sensor, the connected /TE

More information

PLC-RSC- 24UC/21. Extract from the online catalog. Order No.:

PLC-RSC- 24UC/21. Extract from the online catalog. Order No.: Extract from the online catalog PLC-RSC- 24UC/21 Order No.: 2966184 The illustration shows the version PLC-RSC-24DC/21 PLC relay, consisting of base terminal block PLC-BSC.../21 with screw connection and

More information

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature Page 1/7 JUMO ecotrans 03 Microprocessor transmitter/ switching device for /Redox voltage and temperature with a 2-line LCD for mounting on a 35 mm DIN rail Brief description Depending on the configuration,

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

Power supply CP-E 24/10.0 Primary switch mode power supply

Power supply CP-E 24/10.0 Primary switch mode power supply Data sheet Power supply CP-E 24/10.0 Primary switch mode power supply The CP-E range offers enhanced functionality while the number of different types has been considerably reduced. Now all power supply

More information

Relay actuators & Status indicating modules

Relay actuators & Status indicating modules 19 SЕRIES Relay actuators & Status indicating modules Panels for electrical distribution FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage

More information

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase. Extract from the online catalog STEP-PS/1AC/24DC/2.5 Order No.: 2868651 DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase. Commercial data EAN 4046356163224 Pack 1 pcs. Customs tariff

More information

Installation Instructions

Installation Instructions LUCCI Slim Line Fan Remote Control SKU# 210012 Rated Voltage 220-240V~ 50Hz Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all instructions

More information

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Easy Analog RNB130. Technical Information. Primary switched-mode power supply Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power

More information

DALI Professional Controller-4. Control unit Operating instructions

DALI Professional Controller-4. Control unit Operating instructions LI Professional Controller-4 Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Configuration 5 Design 5 Connections

More information

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0 monitoring in conductive liquids 4 probe inputs for level monitoring Multifunction Adjustable sensor voltage Supply voltage 24-240V AC/DC Protective separation of measuring circuit 3 normally open contacts

More information

Power supply CP-D 12/2.1 Primary switch mode power supply

Power supply CP-D 12/2.1 Primary switch mode power supply Data sheet Power supply CP-D 12/2.1 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

Electronic Temperature Controller. Instruction Manual Version

Electronic Temperature Controller. Instruction Manual Version Electronic Temperature Controller 701 Instruction Manual Version 1.00.01 Dear Customer, we have made up this operating manual in such a way that all necessary information about the product can be found

More information

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities. Switching Power Supplies The offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities. With U 508 isting, additional savings in space and cost can be realized

More information

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000 Universal high-voltage isolator. Input voltages up to Vin = ±3600 V. The Task In high-voltage systems, unipolar or bipolar voltage signals ranging from 100 V to 3600 V must be galvanically isolated and

More information